MODBUS Adapter UF-MODBUS410

User Manual APM, ITA 30 - 40kVA, EPM, NX, NXC 30 - 40kVA And NXr Series UPS

Contents
Chapter 1 Product Description ............................................................................................................................................ 1
1.1 Introduction ........................................................................................................................................................... 1
1.2 Specifications And Features ................................................................................................................................. 1
1.3 Appearance And Hardware Description................................................................................................................ 1
Chapter 2 Installation .......................................................................................................................................................... 3
2.1 Unpacking Inspection............................................................................................................................................ 3
2.2 Installation Notes .................................................................................................................................................. 3
2.3 Installation Procedures ......................................................................................................................................... 3
2.3.1 Setting Basic Parameters .......................................................................................................................... 3
2.3.2 Plugging In Adapter ................................................................................................................................... 5
2.3.3 Connecting Communication Cable ............................................................................................................ 5
2.3.4 Setting Communication Parameters In Host Software............................................................................... 6
Chapter 3 Protocol Text ...................................................................................................................................................... 7
3.1 Protocol Text Of UL33 UPS .................................................................................................................................. 7
3.2 Protocol Text Of UH31 UPS ............................................................................................................................... 10
3.3 Protocol Text Of UH11 UPS ............................................................................................................................... 12
3.4 Protocol Text Of iTrust 2G UPS .......................................................................................................................... 13
3.5 Protocol Text Of iTrust Adapt 5/10kVA UPSs ..................................................................................................... 15
3.6 Protocol Text Of NXa, NXb, NXe UPSs .............................................................................................................. 16
3.7 Protocol Text Of Hipulse U UPS And FLP .......................................................................................................... 20
3.8 Protocol Text Of iTrust Adapt 16/20kVA UPS ..................................................................................................... 23
3.9 Protocol Text Of APM 150 UPS .......................................................................................................................... 27
3.10 Protocol Text Of NXr / APM300/EPM UPSs ..................................................................................................... 33
3.11 Protocol Text Of APL(NXp) UPS....................................................................................................................... 37
3.12 ITA/NXC 30/40k UPS........................................................................................................................................ 43
3.13 Protocol Text Of APS UPS ............................................................................................................................... 47
3.14 Protocol Text Of GXE 1-10kVA UPS ................................................................................................................ 52
Chapter 4 Troubleshooting................................................................................................................................................ 54

Chapter 1 Product Description

Chapter 1 Product Description


1.1 Introduction
The UPS JBUS/MODBUS adapter (hereinafter referred to as adapter) allows you to use your host monitoring
software to monitor your Emerson UPS and FLP field lighting power supply system (FLP for short) equipment through
JBUS/MODBUS (RTU) protocol, to learn about the equipment operating status by acquiring the equipment electrical
parameter data, operating data and alarm data.
Currently the adapter supports the UPS and FLP equipment listed in Table 1-1.
Table 1-1
S/N.

UPS and FLP equipment supported by adapter


Equipment

UL33 UPS

UH31 UPS

UH11 UPS

ITrust 2G UPS

iTrust Adapt UPS 5/10/16/20kVA

NXa UPS

NXb UPS

NXe UPS

Equipment series

ITrust series

NX series

Hipulse U UPS 120/160/200/300/400 kVA

10

FLP120/160/200/300/400 kVA

FLP series

11

NXr UPS

NXr series

12

APM 150 UPS

13

APM 300 UPS

14

APL UPS

15

EPM

16

ITA/NXC 30/40K

17

APS

18

GXE 1-10K

Hipulse U series

1.2 Specifications And Features


zProtocol: JBUS/MODBUS (RTU);
zCommunication mode: RS485, RS232;
zSetting range of physical address: 1~31;
zSetting range of communication baud rate: 2400, 4800, 9600 (default), 19200bps;
zCommunication data format: 1 start bit, 8 data bit, 1 stop bit, no parity check;
zCRC16 standard check mode, first high byte, then low byte;
zHot-pluggable, easy to install.

1.3 Appearance And Hardware Description


Appearance
The adapter is a plug-in card, and should be plugged in the SNMP slot of the UPS and FLP. The adapter is shown in
Figure 1-1.

UPS JBUS/MODBUS Adapter

User Manual

Chapter 1 Product Description


Plug -in connector

DIP switch

Host communication LED


Equipment communication LED

Communication port

Figure 1-1

Adapter appearance

Hardware description
The printed board of the adapter is available in two sizes: 130mm (L) 60mm (W) 1.6mm (H) and 130mm (L)
63mm (W) 1.6mm (H); additionally, the former has a narrow opening at the plug-in connector. The former is
applicable to NX, NXr series UPS, iTrust Adapt UPS and APM 150 UPS, while the latter is applicable to Hipulse U
series UPS, FLP, and all iTrust series UPS except for iTrust Adapt UPS.
As shown in Figure 1-1, the adapter provides communication port, equipment communication LED, host
communication LED, plug-in connector and DIP switch, which are described in Table 1-2.
Table 1-2

Hardware description

Name

Communication port

Description

Connects to the host computer, supports RS232 and RS485 communication modes
OFF: power off

equipment communication
LED (yellow)

ON: power on, but communication with UPS or FLP not established

Host communication LED


(green)

OFF: communication with host computer not established

Flash slowly (once per 5s): communication with UPS or FLP failed
Flash quickly (about once per 1s): communication with UPS or FLP is normal
Flash: communication with host computer being normal

Plug-in connector

Plug in the SNMP slot of the UPS or FLP, connect to the UPS or FLP

DIP switch

Used to configure the basic parameters of the adapter

Warning

All external ports of the adapter must connect to SELV circuit. Failure to observe this could cause damage to the adapter.

UPS JBUS/MODBUS Adapter

User Manual

Chapter 2 Installation

Chapter 2 Installation
2.1 Unpacking Inspection
Unpack the adapter, take out the delivery list (see Table 2-1), and check the goods against it. Should there be any
discrepancy, contact the distributor immediately.
Table 2-1

Adapter delivery list

S/N.

Goods

Qty.

Remark

1
2

Adapter
CD

1 pcs
1 pcs

UPS JBUS/MODBUS Adapter User Manual

2.2 Installation Notes


1. The adapter should be installed in the SNMP slot of the UPS or FLP, which is also used for the installation of
SNMP card. Therefore, if you use the adapter, you cannot use the SNMP card.
2. The adapter is available in two sizes, please verify that your adapter matches the UPS or FLP (refer to the
hardware description in section 1.3). Otherwise, the adapter cannot be plugged in the SNMP slot of the UPS or FLP.
3. Some electronic components of the adapter are sensitive to static electricity. To prevent static electricity from
damaging the adapter, do not touch its electronic components or circuits, also avoid their contact with live objects.
Therefore, please hold the side edges of the adapter when moving or installing it.

2.3 Installation Procedures


Please install the adapter in the following sequence:
1. Set the basic parameters of the adapter;
2. Plug the adapter in the SNMP slot;
3. Connect the communication cable;
4. Set the communication parameters in the host software.

2.3.1 Setting Basic Parameters


To enable the functions of the adapter, you must set its basic parameters, which are:
zPhysical address
zCommunication baud rate
These parameters are set by the 8-bit DIP switch of the adapter (refer to Figure 1-1 for its location). The up position
means ON, the down position means OFF, as shown in the following figure.

ON

Figure 2-1

DIP switch

The basic parameters of the adapter are set by Bits 1~7 of the DIP switch, Bit 8 is factory reserved. The setting
shown in Figure 2-1 is the factory default.

UPS JBUS/MODBUS Adapter

User Manual

Chapter 2 Installation
Setting physical address
The physical address of the adapter is set by Bits 1~5. The setting range is 1~31, 0 is factory-reserved setting, 1 is
the factory default.
The physical address setting method is shown in Table 2-2:
Table 2-2

Physical address setting method

Physical address

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON

OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON

OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON

OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON

OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON

Warning

The physical address 0 is factory reserved. You shall not set the physical address to 0; otherwise, the adapter cannot operate
normally.
Setting communication baud rate
The communication baud rate of the adapter is set by Bits 6~7, and can be set to 2400bps, 4800bps, 9600bps, or
19200bps. 9600bps is the factory default.
The communication baud rate setting method is shown in Table 2-3:
Table 2-3

Communication baud rate setting method

Communication baud rate (bps)

Bit 6

Bit 7

2400
4800
9600
19200

OFF
ON
OFF
ON

OFF
OFF
ON
ON

UPS JBUS/MODBUS Adapter

User Manual

Chapter 2 Installation

2.3.2 Plugging In Adapter


Note

The adapter is hot-pluggable. You can install the adapter with shutting down the UPS or FLP.
User the following steps to plug the adapter in the SNMP slot of the UPS or FLP:
1. Remove the SNMP slot cover on the rear panel of the UPS or FLP.
Retain the SNMP slot cover and the screws for use in the future. Refer to the corresponding UPS or FLP user manual
for the location of the SNMP slot.
2. Align the plug-in connector of the adapter with the SNMP slot, plug the adapter into the slot along the grooves on
both sides of the slot, then fix the adapter through the fixing holes on the adapter panel.
More than ten seconds later, you will see the yellow equipment communication LED on the adapter panel flash
quickly, indicating that the adapter has started to operate normally and the communication between the adapter and
the UPS or FLP has been established.

2.3.3 Connecting Communication Cable


Note

RS485 communication cables use twisted-pair.


After plugging in and fixing the adapter, you need to connect the communication cable between the communication
port of the adapter and the RS232 serial port of the computer.
Communication port of the adapter
The communication port of the adapter is shown in Figure 2-2.

Figure 2-2

Communication port

As shown in the figure, the four terminals on the left are for RS485 communication, while the three ones on the right
are for RS232 communication. The terminals are described in Table 2-4.
Table 2-4
Terminal

T+
TTx
Rx
GND

Communication port terminal description

Description
RS485 communication differential signal+, 2 terminals, shorted internally, used for cascade connection
RS485 communication differential signal -, 2 terminals, shorted internally, used for cascade connection
Transmit terminal of RS232 communication signal
Receive terminal of RS232 communication signal
Signal ground

Connecting communication cable


There are two methods to make the communication connection between the adapter and the host computer.
1. RS232 communication
Make the connection between the adapter and the computer using the method shown in Table 2-5.
Table 2-5

Connection bet. adapter and computer (RS232)

Communication port of adapter

RS232 port of computer (DB9 male)

Tx
Rx
GND

Pin 2
Pin 3
Pin 5

UPS JBUS/MODBUS Adapter

User Manual

Chapter 2 Installation
2. RS485 communication
Where RS485 communication is used, please provide an RS232-to-RS485 converter for yourself, and make the
connection between the adapter and the computer using the method shown in Table 2-6 and Table 2-7. For details of
the communication ports of the RS232-to-RS485 converter, please refer to the user manual of the converter.
Table 2-6

Connection bet. adapter and RS232/RS485 converter (RS485)

Communication port of adapter

T+
TTable 2-7

RS485 port of RS232-to-RS485 converter


RS485 communication differential signal +
RS485 communication differential signal -

Connection bet. RS232/RS485 converter and computer (RS485)

RS232 port of RS232-to-RS485 converter

RS232 port of computer (DB9 male)

RS232 data transmission terminal


RS232 data receiving terminal
Signal ground

Pin 2
Pin 3
Pin 5

Warning

RS232 communication and RS485 communication cannot be used at the same time.

2.3.4 Setting Communication Parameters In Host Software


After making communication connection, please start the host monitoring software and set the communication
parameters. Note that the communication parameter settings in the host monitoring software should agree with the
adapters physical address and communication baud rate settings by the DIP switch. For the setting method, refer to
the user manual of the host monitoring software.
After setting the communication parameters in the software, you will see the green host communication LED of the
adapter flash, which indicates that the adapter is in normal operation and the communication between the software
and the adapter has been established. At this point, you can view the UPS or FLP data through the software.
The installation of the adapter is complete.

UPS JBUS/MODBUS Adapter

User Manual

Chapter 3 Protocol Text

Chapter 3 Protocol Text


The preconditions for the users host monitoring software to monitor the UPS or FLP through the adapter is that the
software supports JBUS/MODBUS (RTU) protocol and is able to interpret the JBUS/MODBUS (RTU) protocol text of
the corresponding UPS or FLP.

Note

1. The adapter provides answer only to the #03 query command. It will not answer the query commands of other function codes.
2. When the adapter answers the #03 query command, it will return invalid data address information, with abnormal code #02, if
the required byte of answer information is bigger than 100.
3. In communication through JBUS/MODBUS(RTU) protocol, the adapter is passive, waiting for the host monitoring software to
query it.
The following sections provide the JBUS/MODBUS (RTU) protocol texts of various UPSs or FLPs.

3.1 Protocol Text Of UL33 UPS


1. UPS basic information
ID
1000~1004
1005
1006~1015
1019

Byte

Item
UPS name
UPS firmware release
Manufacturer
Adapter firmware release

Value
"UL33 0200L"
0x010B corresponds to V1.11
"EmersonNetworkPower "
0x010B corresponds to V1.11

Bit 0
Bit 1
Bit 2

Item
UPS alarm flag
Adapter communication failure flag
Not defined

Value
0: Normal; 1: Alarm
0: Normal; 1: Fault

Bit 3

Synchronization/Unsynchronization

Bits 5/4

Mains voltage

Bit 6
Bit 7

Rectifier
Inverter

Bits 9/8

Bypass (voltage or frequency)

Bits 12~10

Battery voltage status

Bits 15~13

Not defined

Bit 0

Battery test result

Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6

Mains frequency
Input transformer over-temperature
Output transformer over-temperature
Inverter SCR damaged
Bypass SCR damaged
User operation error

10
2
20
2

2. UPS alarm data


ID

1030

1031

Bit

UPS JBUS/MODBUS Adapter

User Manual

0: Normal
1: Unsynchronization
00: Normal
01: Abnormal
10:Undervoltage
0: Normal; 1: Fault
0: Normal; 1: Fault
00: Normal
01: Outside synchronization range
10: Outside protection range
000: Normal
001: No battery
010: Below lower limit (EOD point)
011: Above upper limit (voltage too high)
100: Battery reverse connection
101: Pre-alarm
0: Normal;
1: need replacement
0: Normal; 1: Abnormal
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

Chapter 3 Protocol Text


ID

1031

1032

1033

1034

Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Bit

Item
Inverter heatsink over-temperature
Rectifier heatsink over-temperature
Inverter fan failure
Rectifier fan fault
Battery contactor fault
Rectifier input contactor abnormal
Auxiliary contactor abnormal
Input fuse blowout
Output fuse blowout
Module output overload
Parallel system overload
Module overload timeout

Bit 3

Bypass over-current timeout

Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bits 15/14
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bits 15~8

Auxiliary supply 1 failure


Auxiliary supply 2 failure
UPS shutdown due to abnormal bypass
Bypass input phase rotation
Mains input phase rotation
Input soft start fault
AC output overvoltage
Output over-current impact
Inverter module over-current
Rectifier module over-current
Not defined
Transfer to bypass due to load impact
Transfer limitation
Parallel load sharing fault
Turn-off due to low bus voltage
Other module requests transfer to bypass
Ambient temperature too high
Ambient alarm channel 1 fault
Ambient alarm channel 2 fault
Ambient alarm channel 3 fault
Ambient alarm channel 4 fault
Ambient alarm channel 5 fault
Ambient alarm channel 6 fault
Ambient alarm channel 7 fault
Ambient alarm channel 8 fault
Rectifier communication fault
Inverter communication fault
Parallel board fault
DC bus overvoltage fault
Batt. Convertor Fault
Battery Fuse Fault
Batt. Conv. Comm. Fail
Battery Voltage Abnormal
Rectifier inductor over-temperature
Equalize charge overtime
Not defined

UPS JBUS/MODBUS Adapter

User Manual

Value
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failed
0: Normal; 1: Failed
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout
0: Normal;
1: Over-current timeout
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault

0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault

Chapter 3 Protocol Text


3. UPS status data
ID

1040

1041

Bit

Item

Bits 2/1/0

Operation mode

Bit 3

Battery under test

Bits 5/4

Boost/float charge

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Turn-on/off
Generator connection
Input breaker state
Manual bypass breaker state
Automatic bypass breaker state
Output breaker state
Generator operation status
Module output inhibited
Parallel system output inhibited
Not defined

Bits 2/1/0

UPS property

Bits 15~3

Not defined

Value
000: Neither Normal nor Battery mode
001: Normal mode
010: Battery mode
011: Bypass mode
100: Source share mode
0: Not under test; 1: Under test
00: Float charge;
01: Boost charge;
10: Not charging
0: Turn-on; 1: Turn-off
0: Connected; 1: Not connected
0: Open; 1: Closed
0: Open; 1: Closed
0: Open; 1: Closed
0: Open; 1: Closed
0: Not in operation;1: In operation
0: Yes; 1: No
0: Yes; 1: No

000: Single module


001: Master in hot standby
010: slave in hot standby
011: Master in parallel
100: Slave in parallel

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
AC input phase voltage A
AC input phase voltage B
AC input phase voltage C
AC output phase voltage A
AC output phase voltage B
AC output phase voltage C
AC output current A
AC output current B
AC output current C
DC input voltage (battery voltage)
Output frequency (3 phases the same)
AC input line voltage AB
AC input line voltage BC
AC input line voltage CA
Phase A input current
Phase B input current
Phase C input current
Input frequency (3 phases the same)
Input power factor (3 phases the same)
Phase A bypass voltage
Phase B bypass voltage
Phase C bypass voltage
Phase A bypass current
Phase B bypass current
Phase C bypass current
Bypass frequency (3 phases the same)
Battery temperature
Phase A output power factor
Phase B output power factor

UPS JBUS/MODBUS Adapter

User Manual

Value
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100Vdc
5000 corresponds to 50.00Hz
3800 corresponds to 380.0Vac
3800 corresponds to 380.0Vac
3800 corresponds to 380.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
5000 corresponds to 50.00Hz
100 corresponds to 1
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
5000 corresponds to 50.00Hz
1000 corresponds to 100 Celsius degrees
100 corresponds to 1
100 corresponds to 1

10

Chapter 3 Protocol Text


ID
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Phase C output power factor
Phase A output active power
Phase B output active power
Phase C output active power
Battery current
Battery autonomy
Phase A output apparent power
Phase B output apparent power
Phase C output apparent power
Phase A output load percentage
Phase B output load percentage
Phase C output load percentage
Ambient temperature
Phase A output peak value
Phase B output peak value
Phase C output peak value
Reserved
Reserved
Reserved

Value
100 corresponds to 1
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
1000 corresponds to 100.0A
1 corresponds to 1 minute
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
1000 corresponds to 100.0%
1000 corresponds to 100.0%
1000 corresponds to 100.0%
1000 corresponds to 100 Celsius degrees
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1

3.2 Protocol Text Of UH31 UPS


1. UPS basic information
ID
1000~1004
1005
1006~1015
1019

Byte

Item
UPS name
UPS firmware release
Manufacturer
Adapter firmware release

Value
"UH31 0200L"
0x010B corresponds to V1.11
"EmersonNetworkPower "
0x010B corresponds to V1.11

Bit 0
Bit 1
Bit 2
Bit 3

Item
UPS alarm flag
Adapter communication fault flag
Not defined
Synchronization/Unsynchronization

Value
0: Normal; 1: Alarm
0: Normal; 1: Fault

Bits 5/4

Mains voltage phase A

Bits 7/6

Mains voltage phase B

Bits 9/8

Mains voltage phase C

Bit 10
Bit 11

Rectifier
Inverter

Bits 13/12

Bypass voltage

Bits 15~14

Not defined

10
2
20
2

2. UPS alarm data


ID

Bit

1030

UPS JBUS/MODBUS Adapter

User Manual

0: Normal; 1:Unsynchronization
00: Normal
01: Below lower limit (mains failure)
10: Above upper limit
11: Outside specifications
00: Normal
01: Below lower limit (mains failure)
10: Above upper limit
11: Outside specifications
00: Normal
01: Below lower limit (mains failure)
10: Above upper limit
11: Outside specifications
0: Normal; 1: Fault
0: Normal; 1: Fault
00: Normal;
01: Below lower limit ;
10: Outside specifications

Chapter 3 Protocol Text


ID

1031

Bit

Item

Bit 2/1/0

Battery total voltage (+)

Bits 5/4/3

Battery total voltage (-)

Bit 6
Bit 7
Bit 8

Charger fault
Output short circuit
Output overload

Bit 9

Heatsink over-temperature

Bit 10

Mains frequency

Bit 11
Bit 12
Bits 15~13

Neutral line missing


Input phase missing
Not defined

11

Value
000: Normal
001: Below lower limit (EOD point)
010: Above upper limit (voltage too high)
011: Fault
100: Pre-alarm
000: Normal
001: Below lower limit (EOD point)
010: Above upper limit (voltage too high)
011: Fault
100: Pre-alarm
0: Normal; 1: Fault
0: Normal; 1: Short circuit
0: Normal; 1: Overload
0: Normal;
1: Over-temperature
0: Normal;
1: Outside specifications
0: Normal; 1: Fault
0: Normal; 1: Fault

3. UPS status data


ID

1040

Bit

Item

Bit 1/0

Operation mode

Bit 2

Battery under test

Bits 4/3

Boost/float charge (+)

Bits 6/5

Boost/float charge (-)

Bits 8/7

Turn-on/off

Bits 15~9

Not defined

Value
00: Neither Normal nor Battery mode
01: Normal mode
10: Battery mode
11: Bypass mode
0: Not under test; 1: Under test
00: Float charge;
01: Boost charge;
10: Not charging
00: Float charge;
01: Boost charge;
10: Not charging
00: Turn-on; 01: Turn-off;
10: Is turning off

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Phase A input voltage
Phase B input voltage
Phase C input voltage
Bypass voltage
Input frequency
Output voltage
Output current
Output frequency
Battery voltage (+)
Battery voltage (-)
Load percentage
Battery capacity
Internal temperature

UPS JBUS/MODBUS Adapter

Value
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
5000 corresponds to 50.00Hz
2200 corresponds to 220.0Vac
1000 corresponds to 100.0A
5000 corresponds to 50.00Hz
1000 corresponds to 100Vdc
1000 corresponds to 100Vdc
1000 corresponds to 100.0%
1000 corresponds to 100.0%
1000 corresponds to 100 Celsius degrees

User Manual

12

Chapter 3 Protocol Text

3.3 Protocol Text Of UH11 UPS


1. UPS basic information
ID
1000~1004
1005
1006~1015
1019

Byte

10
2
20
2

Item
UPS name
UPS firmware release
Manufacturer
Adapter firmware release

Value
"UH11 0100L"
0x010B corresponds to V1.11
"EmersonNetworkPower "
0x010B corresponds to V1.11

2. UPS alarm data


ID

Bit

Item

UPS alarm flag

0: Normal; 1: Alarm

Bit 1

Adapter communication fault flag

0: Normal; 1: Fault

Bit 2

Not defined

Bit 3

Synchronization/Unsynchronization

0: Normal; 1:Unsynchronization

Bits 5/4

Mains voltage

00: Normal
01: Below lower limit (mains failure)
10: Above upper limit
11: Outside specifications

Bit 6

Rectifier

0: Normal; 1: Fault

Bit 7

Inverter

0: Normal; 1: Fault

Bits 9/8

Bypass voltage

00: Normal;
01: Below lower limit;
10: Above upper limit

Bits 12/11/10

Battery total voltage

000: Normal
001: Below lower limit (EOD point)
010: Above upper limit (voltage too high)
011: Fault;
100: Pre-alarm

Bit 13

Charger fault

0: Normal; 1: Fault

Bit 14

Neutral/live line reversed

0: Normal; 1: Reversed

Bit 15

Output short circuit

0: Normal; 1: Short circuit

Bit 0

Output overload

0: Normal; 1: Overload

Bit 1

Heatsink over-temperature

0: Normal;
1: Over-temperature

Bit 2

Mains frequency

0: Normal; 1: Outside specifications

Bits 15~3

Not defined

1030

1031

Value

Bit 0

3. UPS status data


ID

1040

Bit

Item

Value

Bits 1/0

Operation mode

00: Neither Normal nor Battery mode


01: Normal mode
10: Battery mode
11: Bypass mode

Bit 2

Battery under test

0: Not under test; 1: Under test

Bits 4/3

Boost/float charge

00: Float charge; 01: Boost charge;


10: Not charging

Bits 6/5

Turn-on/off

00: Turn-on; 01: Turn-off


10: Is turning off

Bits 15~7

Not defined

4. UPS analog data


ID

Byte

1050

1051
1052
1053

Item

Value

AC input phase voltage

2200 corresponds to 220.0Vac

AC output phase voltage

2200 corresponds to 220.0Vac

AC output current

1000 corresponds to 100.0A

Battery voltage

1000 corresponds to 100Vdc

UPS JBUS/MODBUS Adapter

User Manual

Chapter 3 Protocol Text


ID

Byte

1054

Output frequency

Item

Value

1055

Input frequency

5000 corresponds to 50.00Hz

1056

Load percentage

1000 corresponds to 100.0%

1057

Battery capacity

1000 corresponds to 100.0%

1058

Internal temperature

1000 corresponds to 100 Celsius degrees

5000 corresponds to 50.00Hz

3.4 Protocol Text Of iTrust 2G UPS


1. UPS basic information
ID

Byte

Item

Value

R/T UPS name: "UH11R0200L"

1000~1004

10

UPS name

1005

UPS firmware release

0x010B corresponds to V1.11

1006~1015

20

Manufacturer

"EmersonNetworkPower "

1019

Adapter firmware release

0x010B corresponds to V1.11

Modular UPS name: "UP11 0200L"

2. UPS alarm data


ID

Bit

Value

UPS alarm flag

0: Normal; 1: Alarm

Bit 1

Adapter communication fault flag

0: Normal; 1: Fault

Bit 2

Not defined

Mains voltage

00: Normal
01: Below lower limit
10: Above upper limit
11: Fault

Bits 6/5

Bypass voltage

00: Normal
01: Below lower limit
10: Above upper limit
11: Fault

Bit 7

Mains frequency

0: Normal; 1: Abnormal

Bit 8

Bypass frequency

0: Normal; 1: Abnormal

Bit 9

Charger module status

0: Normal; 1: Fault

Battery status

000: Float charge


001: Fault
010: Battery low pre-alarm
011: Under test
100: Discharge
101: EOD
110: Boost charge
111: Not charging

Module 1 status

000: Normal
001: Fault
010: Protection
011: Abnormal
100: Communication interrupt
101: Not known

Bits 4/3

1030

Item

Bit 0

Bits 12/11/10

Bits 15/14/13

UPS JBUS/MODBUS Adapter

User Manual

13

14

Chapter 3 Protocol Text


ID

Bit

Value

Module 2 status

000: Normal
001: Fault
010: Protection
011: Abnormal
100: Communication interrupt
101: Not known

Module 3 status

000: Normal
001: Fault
010: Protection
011: Abnormal
100: Communication interrupt
101: Not known

Module 4 status

000: Normal
001: Fault
010: Protection
011: Abnormal
100: Communication interrupt
101: Not known

Module 5 status

000: Normal
001: Fault
010: Protection
011: Abnormal
100: Communication interrupt
101: Not known

Bits 14/13/12

Module 6 status

000: Normal
001: Fault
010: Protection
011: Abnormal
100: Communication interrupt
101: Not known

Bit 15

Not defined

Bits 2/1/0

Bits 5/4/3

1031

Item

Bits 8/7/6

Bits 11/10/9

3. UPS status data


ID

1040

Bit

Item

Value

Bits 1/0

Operation mode

00: Neither Normal nor Battery mode


01: Normal mode
10: Battery mode
11: Bypass mode

Bit 2

ON or OFF state

0: ON ; 1: OFF

Bit 3

Battery test enable

0: Yes; 1: No

Bit 4

Overload transfer limitation enable

0: No; 1: Yes

Bit 5

Redundancy

0: Enough1: Not enough

Bits 15~6

Not defined

4. UPS analog data


ID

Byte

1050

AC input phase voltage

Item

22000 corresponds to 220.0Vac

Value

1051

AC output phase voltage

22000 corresponds to 220.0Vac

1052

AC output current

10000 corresponds to 100.0A

1053

Output frequency

5000 corresponds to 50.00Hz

1054

AC input phase current

10000 corresponds to 100.0A


10000 corresponds to 100.00kW

1055

Input power

1056

Input frequency

5000 corresponds to 50.00Hz

1057

Output active power

10000 corresponds to 100.00kVA

1058

Output apparent power

10000 corresponds to 100.00kVA

1059

Battery autonomy

1000 corresponds to 1000min

1060

Battery voltage

22000 corresponds to 220.0V

1061

Bypass voltage

22000 corresponds to 220.0Vac

UPS JBUS/MODBUS Adapter

User Manual

Chapter 3 Protocol Text


ID

Byte

1062

Item

Value

Bypass current

10000 corresponds to 100.0A

1063

Bypass frequency

5000 corresponds to 50.00Hz

1064

Load percentage

10000 corresponds to 100.0%

3.5 Protocol Text Of iTrust Adapt 5/10kVA UPSs


1. UPS basic information
ID

Byte

Item

Value

1000~1004

10

UPS name
UPS firmware release

R/T UPS name: UHA1R0050L

1005

Manufacturer

0x010B corresponds to V1.11

1006~1015

20

Adapter firmware release

"EmersonNetworkPower"

1019

UPS name

0x010B corresponds to V1.11

2. UPS alarm data


ID

1030

Bit

Value

Bit 0

UPS alarm flag

0: Normal; 1: Alarm

Bit 1

Adapter communication fault flag

0: Normal; 1: Fault

Bit 2

Not defined

Bit 3

Synchronization/Unsynchronization

0: Normal;
1: Unsynchronization

Bits 5/4

Mains status

00: Normal;
01: Abnormal

Bit 6

Rectifier status

0: Normal; 1: Fault

Bit 7

Inverter status

0: Normal; 1: Fault

Bits 9/8

Bypass status

00: Normal; 01: Abnormal

Battery voltage status

00: Normal
01: Below lower limit
10: Above upper limit
11: Fault

Bits 11/10

1031

Item

Bit 12

Heatsink status

0: Normal; 1: Overtemperature

Bit 13

Fan status

0: Normal; 1: Abnormal

Bits 15/14

Neutral line missing

00: Normal
01: Abnormal
10: nonsupport

Bit 0

Bus voltage status

0: Normal; 1: Abnormal

Bit 1

Charge module status

0: Normal; 1: Fault

Bit 2

Battery EOD status

0: Normal; 1: Battery EOD

Bit 3

Auxiliary supply status

0: Normal; 1: Fault

Bit 4

Output overload status

0: Normal; 1: Overload

Bit 5

Output shortcircuit status

0: Normal; 1: Shortcircuit

Bit 6

Overload time-out

0: Normal; 1: Time-out

Bit 7

Boost charge status

0: Normal; 1: Fault

Bit 8

Parallel cable status

0: Normal; 1: Fault

Bits 10/9

Parallel Address Error

00: Normal
01: Alarm
10: No Parallel System

Bits 12/11

Parallel unit communication status

00: Normal
01: Alarm
10: No Parallel System

Bits 14/13

System Overload

00: Normal
01: Alarm
10: No Parallel System

Bit 15

Not defined

UPS JBUS/MODBUS Adapter

User Manual

15

16

Chapter 3 Protocol Text


ID

1032

Bit

Item

Bits 1/0

EPO

Bits 15~2

Not defined

Value

00: Normal
01: EPO
10: nonsupport

3. UPS status data


Bit

ID

Item

Value

Operation mode

00: Neither Normal nor Battery mode


01: Normal mode
10: Battery mode
11: Bypass mode

Bits 3/2

Battery charge state

00: Float charge


01: Boost charge
10: Neither charge nor discharge
11: Discharge

Bit 4

Battery self-test state

0: Not under test


1: Under test

Bit 5

Battery self-test enable

0: Enabled
1: Not enabled

Bit 6

Battery low pre-alarm

0: Battery voltage normal


1: Battery low pre-alarm

Bit 7

Switch-on or switch-off

0: On; 1: Off

Bits 15~8

Not defined

Bits 1/0

1040

4. UPS analog data


ID

Byte

1050

1051
1052

Item

Value

AC input phase voltage A

22000 corresponds to 220.0Vac

AC input phase voltage B

22000 corresponds to 220.0Vac

AC input phase voltage C

22000 corresponds to 220.0Vac

1053

AC output phase voltage

22000 corresponds to 220.0Vac

1054

AC output current

10000 corresponds to 100.0A

1055

Battery voltage

22000 corresponds to 220.0Vdc


5000 corresponds to 50.00Hz

1056

Output frequency

1057

Input frequency

5000 corresponds to 50.00Hz

1058

Bypass voltage

22000 corresponds to 220.0Vac

1059

Bypass current

10000 corresponds to 100.0A


10000 corresponds to 100.00kW

1060

AC output active power

1061

AC output apparent power

10000 corresponds to 100.00kVA

1062

AC output load percentage

10000 corresponds to 100.0%

1063

Bypass frequency

5000 corresponds to 50.00Hz

3.6 Protocol Text Of NXa, NXb, NXe UPSs


1. UPS basic information
ID
1000~1004
1005
1006~1015
1019

Byte

10
2
20
2

Item
UPS name
UPS firmware release
Manufacturer
Adapter firmware release

UPS JBUS/MODBUS Adapter

Value
"UH33 0200L"
0x010B corresponds to V1.11
"EmersonNetworkPower "
0x010B corresponds to V1.11

User Manual

Chapter 3 Protocol Text


2. UPS alarm data
ID

Bit 0
Bit 1
Bit 2

Bit

Item
UPS alarm flag
Adapter communication fault flag
Not defined

Value

Bit 3

Synchronization/Unsynchronization

Bit 4
Bit 5
Bit 6

Rectifier input voltage


Rectifier
Inverter

Bit 7

Bypass (voltage or frequency)

Bits 10/9/8

Battery total voltage

Bit 11

Rectifier input frequency

Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Balanced inductor over-temperature


Input inductor over-temperature
Rectifier over-temperature
Balanced circuit fault
Balanced circuit overcurrent
Battery contactor fault
Battery converter fault
Battery converter overcurrent
Battery converter overtemperature
Rectifier input fuse
Auxiliary supply 1 failure
Rectifier input phase rotation fault
Rectifier overcurrent
Soft start fault
Bypass overcurrent fault
Inverter inductor overtemperature
Inverter overtemperature
Fan fault
Inverter SCR fault
Bypass SCR fault
User operation error
Output fuse blowout
Auxiliary supply 2 failure
Module output overload
Parallel system overload
Module overload timeout
Shutdown due to abnormal bypass
AC output overvoltage
Inverter current
Bypass phase rotation fault
Transfer to bypass due to load impact
Bypass transfer limitatation
Parallel load sharing fault
Turnoff due to abnormal bus voltage
Other module requests tansfer to bypass
Parallel board fault

0: Normal; 1: Alarm
0: Normal; 1: Fault

1030

1031

1032

UPS JBUS/MODBUS Adapter

0: Normal
1: Unsynchronization
0: Normal; 1: Abnormal
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal
1: Outside specifications
000: Normal
001: Below lower limit (EOD point)
010: Above upper limit (voltage too high)
011: No battery
100: Pre-alarm
101: Battery reverse connection
0: Normal
1: Outside specifications
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Overcurrent
0: Normal; 1: Overtemperature
0: Normal; 1: Blown out
0: Normal; 1: Failed
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Overtemperature
0: Normal; 1: Overtemperature
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Error
0: Normal; 1: Blown out
0: Normal; 1: Failed
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout
0: Normal; 1: Abnormal
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault

User Manual

17

18

Chapter 3 Protocol Text


ID

1033

1034

Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10

Item
DC bus overvoltage fault
Parallel cable connection fault
Ambient temperature too high
Rectifier communication fault
Inverter communication fault
Parallel communication fault
Output DC component too big fault
Parallel system battery pre-alarm fault
Input neutral line missing
Inverter contactor fault
Rectifier fault

Bits 12/11

Battery life

Bit 13
Bit 14
Bit 15

EPO
Battery temperature too high
Not defined

Bit 0

BCB status

Bit 2
Bit 3
Bits 15~4

Battery earthing
Equalize charge overtime
Not defined

Value
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
00: Normal
01: Battery needs replacement
10: Life span terminates
0: Normal; 1: Fault
0: Normal; 1: Fault

00:BCB not connected


01:BCB closed
10:BCB open
0: Normal; 1: Fault
0: Normal; 1: Fault

3. UPS status data


ID

1040

1041

Bit

Item

Bits 2/1/0

Operation mode

Bit 3

Battery under test

Bits 5/4

Boost/float charge

Bit 6

Turn-on/off

Bit 7

Generator connection

Bit 8
Bit 9
Bit 10
Bit 11

Input breaker state


Maintenance bypass breaker state
Bypass breaker state
Output breaker state

Bits 14/13/12

Bypass rotary switch state

Bit 15

Not defined

Bit 1/0

Parallel system operation mode

Bits 15~2

Not defined

Value
000: Neither Normal nor Battery mode
001: Normal mode
010: Battery mode
011: Bypass mode
100: Source share mode
0: Not under test;1: Under test
00: Float charge;
01: Boost charge
10: Not charging
0: Turn-on; 1: Turn-off
0: Connected
1: Not connected
0: Open; 1: Closed
0: Open;1: Closed
0: Open; 1: Closed
0: Open; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass state
100: Maintenance state

00: Normal mode


01: Battery mode
10: Bypass mode
11: No output

4. UPS analog data


ID
1050
1051
1052

Byte

2
2
2

Item
AC input phase voltage A
AC input phase voltage B
AC input phase voltage C

UPS JBUS/MODBUS Adapter

Value
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac

User Manual

Chapter 3 Protocol Text


ID
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
AC output phase voltage A
AC output phase voltage B
AC output phase voltage C
AC output current A
AC output current B
AC output current C
Battery voltage
Output frequency (3 phases the same)
AC input line voltage AB
AC input line voltage BC
AC input line voltage CA
Phase A input current
Phase B input current
Phase C input current
Input frequency (3 phases the same)
Phase A input power factor
Phase B input power factor
Phase C input power factor
Phase A bypass voltage
Phase B bypass voltage
Phase C bypass voltage
Bypass frequency (3 phases the same)
Battery current
Phase A output power factor
Phase B output power factor
Phase C output power factor
Module Phase A output peak value
Module Phase B output peak value
Module Phase C output peak value
Module Phase A output active power
Module Phase B output active power
Module Phase C output active power
Module Phase A output apparent power
Module Phase B output apparent power
Module Phase C output apparent power
Module Phase A output load percentage
Module Phase B output load percentage
Module Phase C output load percentage
Module Phase A output reactive power
Module Phase B output reactive power
Module Phase C output reactive power
System Phase A output active power
System Phase B output active power
System Phase C output active power
System Phase A output apparent power
System Phase B output apparent power
System Phase C output apparent power
System Phase A output reactive power
System Phase B output reactive power
System Phase C output reactive power
Battery autonomy
Battery temperature
Ambient temperature
Battery voltage (-)
Battery current (-)

UPS JBUS/MODBUS Adapter

Value
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100Vdc
5000 corresponds to 50.00Hz
3800 corresponds to 380.0Vac
3800 corresponds to 380.0Vac
3800 corresponds to 380.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
5000 corresponds to 50.00Hz
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
5000 corresponds to 50.00Hz
1000 corresponds to 100.0A
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
1000 corresponds to 100.0%
1000 corresponds to 100.0%
1000 corresponds to 100.0%
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
1 corresponds to 1 minute
1000 corresponds to 100 Celsius degrees
1000 corresponds to 100 Celsius degrees
1000 corresponds to 100Vdc
1000 corresponds to 100.0A

User Manual

19

20

Chapter 3 Protocol Text

3.7 Protocol Text Of Hipulse U UPS And FLP


1. UPS basic information
ID
1000~1004
1005
1006~1015
1019

Byte

Item
UPS name
UPS firmware release
Manufacturer
Adapter firmware release

Value
"HL33 0200L"
"0100" corresponds to V1.0
"EmersonNetworkPower "
0x1234 corresponds to Ver12.34

Bit
Bit 0
Bit 1
Bit 2

Item
UPS alarm flag
Adapter communication fault flag
Not defined

0: Normal; 1: Alarm
0: Normal; 1: Fault

Bit 3

Synchronization/Unsynchronization

Bit 4
Bit 5
Bit 6

Rectifier input voltage


Rectifier
Inverter

Bit 7

Bypass (voltage or frequency)

Bits 10/9/8

Battery total voltage

Bit 11

Rectifier input frequency

Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Input fuse
Mains phase
REC input Phase
Control power 1
Control power 2
Rectifier
Soft start
Rectifier overtemp.
Input filter fault
Input filter transfer time-out
Filter contactor fault
REC drive cirtuit fault
Rectifier comm. fail
Inverter overtemp.
Fan fault
Inverter STS fail
Bypass STS fail
Operation invalid
Unit over load
System over load

10
2
20
2

2. UPS alarm data


ID

1030

1031

UPS JBUS/MODBUS Adapter

Value

0: Normal
1: Unsynchronization
0: Normal; 1: Abnormal
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal
1: Outside specifications
000: Normal
001: Below lower limit (EOD point)
010: Above upper limit (voltage too high)
011: No battery
100: Pre-alarm
101: Battery reverse connection
0: Normal;
1: Outside specifications
0: Normal; 1 Fail:
0: Normal; 1: Reversed
0: Normal; 1: Missing
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Current limit
0: Normal; 1: Fail
0: Normal; 1: Overtemp.
0: Normal; 1: Fault
0: Normal; 1: Time-out
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fail
0: Normal; 1: Overtemp.
0: Normal; 1: Fault
0: Normal; 1: Fail
0: Normal; 1: Fail
0: Normal; 1: Invalid
0: Normal; 1: Over load
0: Normal; 1: Over load

User Manual

Chapter 3 Protocol Text


ID

1032

1033

1034

Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13

Item
Unit over load time-out
Byp. abnormal shutdown
Output over voltage
Inverter over current
Bypass phase
Load impact transfer
Transfer time-out
Load sharing fault
DC bus abnormal
System transfer
Parallel board fault
Parallel connect fault
Parallel comm. fail
Bypass over current

Bits 15/14

LBS Active/Fault

Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7

Bypass induct overtemp.


Static Sw. overtemp.
Bypass feedback fault
INV. drive circuit fault
Inverter comm. fail
System Battery low pre-warning
EPO
Ambient overtemp.

Bits 9/8

Battery life

Bit 10
Bit 11
Bit 12

Battery overtemp.
Battery ground fault
Battery fuse fail

Bits 14/13

BCB status

Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bits 15~9

Output fuse fail (no use)


Bus capacitor over voltage
DC bus over voltage
Bus short-circuit fault(no use)
Input current uneven
Output capacitor need maintenance
Input filter transfer time-out
Battery SCR fault
PFC mode abnormal
Equalize charge overtime
Not use

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Time-out
0: Normal; 1: Shutdown
0: Normal; 1: Over voltage
0: Normal; 1: Over current
0: Normal; 1: Reverse
0: Normal; 1: Transfer
0: Normal; 1: Time-out
0: Normal; 1: Fault
0: Normal; 1: Abnormal
0: Normal; 1: Transfer
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Over current
00: Not Active
01: Active
10: Fault
0: Normal; 1: Overtemp
0: Normal; 1: Overtemp
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Warning
0: Normal; 1: EPO
0: Normal; 1: Overtemp.
00: Normal
01: Battery needs replacement
10: Life span terminates
0: Normal; 1: Overtemp.
0: Normal; 1: Fault
0: Normal; 1: Fault
00: BCB not connected
01: BCB closed
10: BCB open
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Time-out
0: Normal; 1: Fault
0: Normal; 1: Fault
0: Normal; 1: Fault

User Manual

21

22

Chapter 3 Protocol Text


3. UPS status data
ID

1040

1041

Bit

Item

Bits 2/1/0

Operation mode

Bit 3

Battery selftest

Bits 5/4

Boost/float charge

Bit 6

Turn-on/off

Bit 7

Generator connection

Bit 8
Bit 9
Bit 10
Bit 11

Input breaker state


Maintenance bypass breaker state
Bypass breaker state
Output breaker state

Bits 13/12

Parallel system operation mode

Bits 15/14

No use

Bits 2/1/0

Bypass rotary switch state

Bit 3

Filter state

Bit 4

Sleep state

Bit 5

Rectifier work state

Bits 15~6

No use

Value
000: Neither Normal nor Battery mode
001: Normal mode
010: Battery mode
011: Bypass mode
100: Source share mode
0: Not under test
1: Under test
00: Float charge
01: Boost charge
10: Not charging
0: Turn-on; 1: Turn-off
0: Connected
1: Not connected
0: Open; 1: Closed
0: Open; 1: Closed
0: Open; 1: Closed
0: Open; 1: Closed
00: Normal mode
01: Battery mode
10: Bypass mode
11: No output

000: Closed
001: Under test
010: Normal
011: Bypass state
100: Maintenance state
0: Not Connected
1: connected
0: Not Sleep
1: Sleep
0: normal mode
1: PFC mode

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
AC output phase voltage A
AC output phase voltage B
AC output phase voltage C
AC output current A
AC output current B
AC output current C
Battery voltage
Output frequency (3 phases the same)
AC input line voltage AB
AC input line voltage BC
AC input line voltage CA
Phase A input current
Phase B input current
Phase C input current
Input frequency (3 phases the same)
Total input power factor
Phase A bypass voltage
Phase B bypass voltage
Phase C bypass voltage
Bypass frequency (3 phases the same)
Battery current

UPS JBUS/MODBUS Adapter

Value
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100Vdc
5000 corresponds to 50.00Hz
3800 corresponds to 380.0Vac
3800 corresponds to 380.0Vac
3800 corresponds to 380.0Vac
1000 corresponds to 100.0A
1000 corresponds to 100.0A
1000 corresponds to 100.0A
5000 corresponds to 50.00Hz
100 corresponds to 1
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
2200 corresponds to 220.0Vac
5000 corresponds to 50.00Hz
1000 corresponds to 100.0A

User Manual

Chapter 3 Protocol Text


ID
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Phase A output power factor
Phase B output power factor
Phase C output power factor
Module Phase A output peak value
Module Phase B output peak value
Module Phase C output peak value
Module Phase A output active power
Module Phase B output active power
Module Phase C output active power
Module Phase A output apparent power
Module Phase B output apparent power
Module Phase C output apparent power
Module Phase A output load percentage
Module Phase B output load percentage
Module Phase C output load percentage
Module Phase A output reactive power
ModulePhase B output reactive power
ModulePhase C output reactive power
System Phase A output active power
System Phase B output active power
System Phase C output active power
System Phase A output apparent power
System Phase B output apparent power
System Phase C output apparent power
System Phase A output reactive power
System Phase B output reactive power
System Phase C output reactive power
Battery autonomy
Battery temperature
Ambient temperature
Battery aging ratio

Value
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
100 corresponds to 1
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
1000 corresponds to 100.0%
1000 corresponds to 100.0%
1000 corresponds to 100.0%
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kW
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
10000 corresponds to 100.00kVA
1 corresponds to 1 minute
1000 corresponds to 100 Celsius degrees
1000 corresponds to 100 Celsius degrees
10000 corresponds to 100

3.8 Protocol Text Of iTrust Adapt 16/20kVA UPS


1. UPS basic information
ID

1000 ~ 1004

Byte

10

Item

Value

UPS name

HR331500
0x0201 to V2.01

1005

UPS firmware release

1006 ~ 1015

20

Manufacturer

EmersonNetworkPower

1019

Adapter firmware release

0x0201 to V2.01

UPS JBUS/MODBUS Adapter

User Manual

23

24

Chapter 3 Protocol Text


2. UPS alarm data
ID

Bit
Bit 0

Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7

Item
UPS general alarm flag bit
Modbus card/dry contactor card communication
failure flag bit
Reserved
Inverter synchronous/asynchronous
Mains voltage
Rectifier status
Inverter status
Bypass conditions (voltage or frequency)

1032

0: Normal; 1: Failure

Bits
10/9/8

Battery 1 status

Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5

Functional module 1 failure


Functional module 2 failure
Functional module 3 failure
Functional module 4 failure
Functional module 5 failure
Functional module 6 failure
Functional module 7 failure
Functional module 8 failure
Functional module 9 failure
Functional module 10 failure
LBS abnormal

Bit 7/6

Keyboard failure or model capacity invalid

Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4

Fan failure
Environmental temperature over-high
Emergency power off
Bypass thyristor failure
Bypass phase sequence reverse
Bypass over-current failure
Bypass abnormal power off
Bypass switching number limit
Failure of module combining board
Failure of module combining cable
Communication failure of module combining
Auxiliary power 2 power off
Contactor power board 1 failure

0: Synchronous; 1: Asynchronous
0: Synchronous; 1: Asynchronous
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Excessive
000: Normal
001: Below the lower limit (power-off point)
010: Above the upper limit (excessive voltage)
011: No battery
100: Pre-alarm
101: Reverse batteries
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
00: Normal; 01: Keyboard failure
10: Model capacity invalid
0: Normal; 1: Failure
0: Normal; 1: Over-high
0: Normal; 1: Power off
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

Bit 5

Contactor power board 2 failure

0: Normal; 1: Failure

Bit 6

Redundant fan power failure

Bit 8/7

BCB access status

Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery 1 contactor failure


Battery 2 contactor failure
Battery 1 converter failure
Battery 2 converter failure
Battery 1 converter over-current
Battery 2 converter over-current
Battery 1 converter over-temperature

0: Normal; 1: Abnormal
00: BCB not accessed; 01: BCB closed
03: BCB disconnected
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Over-temperature

1030

1031

Value

0: Normal; 1: Alarm

UPS JBUS/MODBUS Adapter

User Manual

Chapter 3 Protocol Text


ID

1033

1034

Bit
Bit 0
Bit 1
Bit 2

Item
Battery 2 converter over-temperature
Battery 1 charger failure
Battery 2 charger failure

Bit 4/3

Battery 1 life

Bit 6/5

Battery 2 life

Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0

Battery 1 temperature over-high


Battery 1 temperature over-high
Battery 1 grounding failure
Battery 1 grounding failure
Master channel frequency abnormal
Balance inductor over-temperature
Input inductor over-temperature
Rectifier over-temperature
Balance circuit failure
Balance inductor over-current
Master fuse broken
Auxiliary power 1 power-off
Master channel phase sequence reverse
Rectifier over-current
Software start failure
Inversion inductor over-temperature
Inductor over-temperature
Inversion thyristor failure
User operation error
Output fuse broken
Single unit output overload
Combined system overload
Single unit overload timeout
AC output over-voltage
Inverter over-current
Turning to bypass due to load impact
Failure of current sharing in combined units
Abnormal power-off of bus
Turning to bypass due to request by neighbor
system
DC bus over-voltage failure
Rectifier communication failure
Inverter communication failure
Output DC excess failure
Combined system battery pre-alarm failure
Input zero-lacking failure
Inversion contactor failure
Input contactor failure
Input current abnormal
Output voltage abnormal
Input current excessive
Bypass over-temperature
Thyristor failure in neighboring unit

Bit 115

Reserved

Bit 3

1035

1036

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure
00: Normal; 01: Battery to be replaced
10: Battery life ended
00: Normal; 01: Battery to be replaced
10: Battery life ended
0: Normal; 1: Over-high
0: Normal; 1: Over-high
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Excessive
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Broken
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Error
0: Normal; 1: Broken
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout
0: Normal; 1: Over-voltage
0: Normal; 1: Over-current
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

User Manual

25

26

Chapter 3 Protocol Text


3. UPS status data
ID

1040

Bit

Value
00: UPS power supply; 01: Bypass power
supply
10: No power supply
0: In self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non-charging status
0: Power-off; 1: Power-on
00: Master channel input, rectifier started
01: Battery input, rectifier started
10: Combined input, rectifier started
11: No input from master channel or batteries
0: Generator accessed; 1: Generator not
accessed
0: Disconnected; 1: Closed

Bit 1/0

Power supply mode

Bit 2

Battery 1 self-check

Bit 4/3

Battery 1 average charge/floating charge

Bit 5

Integrated equipment power-on/off

Bit 7/6

Rectifier power supply status

Bit 8

Integrated generator access event

Bit 9

Bit 11
Bit 12

Integrated equipment input air breaker status


Integrated equipment maintenance bypass air
breaker status
Integrated equipment bypass air breaker status
Integrated equipment output air breaker status

Bit
15/14/13

Integrated equipment revolving air breaker


status

Bits 2/1/0

Rack combined system power supply status

Bit 3

Battery 2 battery self-check

Bit 5/4

Battery 2 floating / average charge status

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Module 1 online or offline


Module 2 online or offline
Module 3 online or offline
Module 4 online or offline
Module 5 online or offline
Module 6 online or offline
Module 7 online or offline
Module 8 online or offline
Module 9 online or offline
Module 10 online or offline

0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass
100: Maintenance
000: No power supply
001: Bypass power supply
010: Mains supply
011: Battery inversion power supply
100: United power supply
101: Output prohibited
0: in self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non charge
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline

Item
Input phase voltage A
Input phase voltage B
Input phase voltage C
Output phase voltage A
Output phase voltage B
Output phase voltage C
Output phase current A
Output phase current B
Output phase current C
DC input voltage (Battery 1 voltage)
Output frequency (consistency in three phases)
Input cable voltage AB
Input cable voltage BC

0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.1V
0.01Hz
0.1V
0.1V

Bit 10

1041

Item

0: Disconnected; 1: Closed

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2

UPS JBUS/MODBUS Adapter

Value

User Manual

Chapter 3 Protocol Text


ID
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Input cable voltage CA
Input phase current A
Input phase current B
Input phase current C
Input frequency (consistency in three phases
Phase A input power factor
Phase B input power factor
Phase C input power factor
Bypass phase voltage A
Bypass phase voltage B
Bypass phase voltage C
Bypass frequency
Phase A output power factor
Phase B output power factor
Phase C output power factor
Phase A output peak ratio
Phase B output peak ratio
Phase C output peak ratio
Phase A output active power
Phase B output active power
Phase C output active power
Phase A output reactive power
Phase B output reactive power
Phase C output reactive power
Phase A output apparent power
Phase B output apparent power
Phase C output apparent power
Battery backup time
Positive battery voltage
Positive battery current
Negative battery voltage
Negative battery current
Battery aging coefficient
Battery temperature
Environmental temperature

Value

0.1V
0.1A
0.1A
0.1A
0.01Hz
0.01
0.01
0.01
0.1V
0.1V
0.1V
0.01Hz
0.01
0.01
0.01
0.01
0.01
0.01
0.01kW
0.01kW
0.01kW
0.01kVA
00.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01kVA
Minute
0.1V
0.1A
0.1V
0.1A
0.1
0.1C
0.1C

3.9 Protocol Text Of APM 150 UPS


1. UPS basic information
ID

Byte

1000 ~ 1004

10

Item

Value

UPS name

APM 150

1005

UPS firmware release

0x0210 to V2.10

1006 ~ 1015

20

Manufacturer

EmersonNetworkPower

1016

UPS extension name

Reserved

1019

Adapter firmware release

0x0210 to V2.10

2. UPS alarm data


ID

1030

Bit
Bit 0

Bit 2

Item
UPS general alarm flag bit
Modbus card/dry contactor card communication
failure flag bit
Reserved

Bit 3

Inverter synchronous/asynchronous

Bit 1

UPS JBUS/MODBUS Adapter

Value

0: Normal; 1: Alarm
0: Normal; 1: Failure

0: Synchronous; 1: Asynchronous

User Manual

27

28

Chapter 3 Protocol Text


ID

1030

Bit
Bit 4
Bit 5
Bit 6
Bit 7

Item
Mains voltage
Rectifier status
Inverter status
Bypass conditions (voltage or frequency)

Bits
10/9/8

Battery 1 status

Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5

Functional module 1 failure


Functional module 2 failure
Functional module 3 failure
Functional module 4 failure
Functional module 5 failure
Functional module 6 failure
Functional module 7 failure
Functional module 8 failure
Functional module 9 failure
Functional module 10 failure
LBS abnormal

Bits 7/6

Keyboard failure or model capacity invalid

Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4

Fan failure
Environmental temperature over-high
Emergency power off
Bypass thyristor failure
Bypass phase sequence reverse
Bypass over-current failure
Bypass abnormal power off
Bypass switching number limit
Failure of module combining board
Failure of module combining cable
Communication failure of module combining
Auxiliary power 2 power off
Contactor power board 1 failure

Value
0: Synchronous; 1: Asynchronous
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Excessive
000: Normal
001: Below the lower limit (power-off point)
010: Above the upper limit (excessive voltage)
011: No battery
100: Pre-alarm
101: Reverse batteries
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
00: Normal
01: Keyboard failure
10: Model capacity invalid
0: Normal; 1: Failure
0: Normal; 1: Over-high
0: Normal; 1: Power off
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

Bit 5

Contactor power board 2 failure

0: Normal; 1: Failure

Bit 6

Redundant fan power failure

Bits 8/7

BCB access status

Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Battery 1 contactor failure


Battery 2 contactor failure
Battery 1 converter failure
Battery 2 converter failure
Battery 1 converter over-current
Battery 2 converter over-current
Battery 1 converter over-temperature
Battery 2 converter over-temperature
Battery 1 charger failure
Battery 2 charger failure

Bits 4/3

Battery 1 life

Bits 6/5

Battery 2 life

Bit 7

Battery 1 temperature over-high

0: Normal; 1: Abnormal
00: BCB not accessed
01: BCB closed
03: BCB disconnected
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure
00: Normal
01: Battery to be replaced
10: Battery life ended
00: Normal
01: Battery to be replaced
10: Battery life ended
0: Normal; 1: Over-high

1031

1032

1033

UPS JBUS/MODBUS Adapter

User Manual

Chapter 3 Protocol Text


ID

1033

1034

Bit
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Bit 3

1035

Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1

1036

Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bits 11
15

Item
Battery 2 temperature over-high
Battery 1 grounding failure
Battery 2 grounding failure
Master channel frequency abnormal
Balance inductor over-temperature
Input inductor over-temperature
Rectifier over-temperature
Balance circuit failure
Balance inductor over-current
Master fuse broken
Auxiliary power 1 power-off
Master channel phase sequence reverse
Rectifier over-current
Software start failure
Inversion inductor over-temperature
Inductor over-temperature
Inversion thyristor failure
User operation error
Output fuse broken
Single unit output overload
Combined system overload
Single unit overload timeout
AC output over-voltage
Inverter over-current
Turning to bypass due to load impact
Failure of current sharing in combined units
Abnormal power-off of bus
Turning to bypass due to request by neighbor
system
DC bus over-voltage failure
Rectifier communication failure
Inverter communication failure
Output DC excess failure
Combined system battery pre-alarm failure
Input zero-lacking failure
Inversion contactor failure
Input contactor failure
Input current abnormal
Output voltage abnormal
Input current excessive
Bypass over-temperature
Thyristor failure in neighboring unit
External input isolated transformer
over-temperature
External input isolated transformer fan failure
Bypass transformer over-temperature
Top-outlet Fan fault
Loss of redundancy
Capacity Exceeded
Functional module 11 failure
Functional module 12 failure
Bypass not available
Equalize charge overtime

Value
0: Normal; 1: Over-high
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Excessive
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Broken
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Error
0: Normal; 1: Broken
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout
0: Normal; 1: Over-voltage
0: Normal; 1: Over-current
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

Reserved

UPS JBUS/MODBUS Adapter

User Manual

29

30

Chapter 3 Protocol Text


3. UPS status data
ID

Bit

Item

Bits 1/0

Power supply mode

Bit 2

Battery 1 self-check

Bits 4/3

Battery 1 average charge/floating charge

Bit 5

Integrated equipment power-on/off

Bit 7/6

Rectifier power supply status

Bit 8

Integrated generator access event

Bit 9

Bit 11
Bit 12

Integrated equipment input air breaker status


Integrated equipment maintenance bypass air
breaker status
Integrated equipment bypass air breaker status
Integrated equipment output air breaker status

Bits
15/14/13

Integrated equipment revolving air breaker


status

Bits 2/1/0

Rack combined system power supply status

Bit 3

Battery 2 battery self-check

Bit 5/4

Battery 2 floating / average charge status

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Module 1 online or offline


Module 2 online or offline
Module 3 online or offline
Module 4 online or offline
Module 5 online or offline
Module 6 online or offline
Module 7 online or offline
Module 8 online or offline
Module 9 online or offline
Module 10 online or offline

0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass
100: Maintenance
000: No power supply
001: Bypass power supply
010: Mains supply
011: Battery inversion power supply
100: United power supply
101: Output prohibited
0: In self-check; 1: Not in self-check
00: Floating charge
01: Average charge
10: Non charge
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline

Bit 0

Frequency Converter Mode or Normal Mode

0Normal Mode1Frequency Converter Mode

Bit 1

ECO Mode or Normal Mode

0Normal Mode1ECO Mode

Bit 2
Bit 3

Module 11 online or offline


Module 12 online or offline

0: Online; 1: Offline
0: Online; 1: Offline

Bits 415

Reserved

1040

Bit 10

1041

1042

Value
00: UPS power supply
01: Bypass power supply
10: No power supply
0: In self-check; 1: Not in self-check
00: Floating charge
01: Average charge
10: Non-charging status
0: Power-off; 1: Power-on
00: Master channel input, rectifier started
01: Battery input, rectifier started
10: Combined input, rectifier started
11: No input from master channel or batteries
0: Generator accessed
1: Generator not accessed
0: Disconnected; 1: Closed

0: Disconnected; 1: Closed

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055

Byte

2
2
2
2
2
2

Item
Input phase voltage A
Input phase voltage B
Input phase voltage C
Output phase voltage A
Output phase voltage B
Output phase voltage C

UPS JBUS/MODBUS Adapter

Value

0.1V
0.1V
0.1V
0.1V
0.1V
0.1V

User Manual

Chapter 3 Protocol Text


ID
1056
1057
1058
1059
1060
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Output phase current A
Output phase current B
Output phase current C
DC input voltage (Battery 1 voltage)
Output frequency (consistency in three phases)
Input cable voltage AB
Input cable voltage BC
Input cable voltage CA
Input phase current A
Input phase current B
Input phase current C
Input frequency (consistency in three phases)
Phase A input power factor
Phase B input power factor
Phase C input power factor
Bypass phase voltage A
Bypass phase voltage B
Bypass phase voltage C
Bypass frequency
Phase A output power factor
Phase B output power factor
Phase C output power factor
Phase A output peak ratio
Phase B output peak ratio
Phase C output peak ratio
Phase A output active power
Phase B output active power
Phase C output active power
Phase A output reactive power
Phase B output reactive power
Phase C output reactive power
Phase A output apparent power
Phase B output apparent power
Phase C output apparent power
Phase A output load percentage
Phase B output load percentage
Phase C output load percentage
Battery backup time
Positive battery voltage
Positive battery current
Negative battery voltage
Negative battery current
Battery aging coefficient

0.1A
0.1A
0.1A
0.1V
0.01Hz
0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.01Hz
0.01
0.01
0.01
0.1V
0.1V
0.1V
0.01Hz
0.01
0.01
0.01
0.01
0.01
0.01
0.01kW
0.01kW
0.01kW
0.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01
0.01
0.01
Minute
0.1V
0.1A
0.1V
0.1A
0.1

1103

Battery temperature

0.1

1104

Environmental temperature

0.1

UPS JBUS/MODBUS Adapter

Value

User Manual

31

32

Chapter 3 Protocol Text


5. SPM alarm data
ID

Bit
Bit 2/1/0
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14

2000

2001+n (0N17)

Item
Reserved
Inside communication status
Input dry contactor 1 status
Input dry contactor 2 status
Input dry contactor 3 status
Input dry contactor 4 status
Collaction board 5 ready status
Collaction board 6 ready status
Collaction board 7 ready status
Collaction board 8 ready status
Collaction board 10 ready status
Collaction board 11 ready status
Collaction board 12 ready status
CRC check status
Branch 3n+1 over-current
Branch 3n+1 ultra-high current threshold
Branch 3n+1 low current threshold
Branch 3n+1 impact over-current
Branch 3n+1 switch abnormal
Branch 3n+2 over-current
Branch 3n+2 ultra-high current threshold
Branch 3n+2 low current threshold
Branch 3n+2 impact over-current
Branch 3n+2 switch abnormal
Branch 3n+3 over-current
Branch 3n+3 ultra-high current threshold
Branch 3n+3 low current threshold
Branch 3n+3 impact over-current
Branch 3n+3 switch abnormal

Value

0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm
0: Normal; 1: Alarm

6. SPM analog data


ID
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
SPM Branch 1 current
SPM Branch 1 power (kWh)
SPM Branch 1 switch status
SPM Branch 1 active power
SPM Branch 1 apparent power
SPM Branch 1 THDi
SPM Branch 1 rated current
SPM Branch 1 load ratio
SPM Branch 1 power factor
SPM Branch 1 reserved
SPM Branch 1 reserved
SPM Branch 1 reserved
SPM Branch 1 reserved
SPM Branch 1 reserved
SPM Branch 1 reserved
SPM Branch 2 current
SPM Branch 2 power (kWh)
SPM Branch 2 switch status
SPM Branch 2 active power
SPM Branch 2 apparent power
SPM Branch 2 THDi
SPM Branch 2 rated current
SPM Branch 2 load ratio
SPM Branch 2 power factor
SPM Branch 2 reserved

UPS JBUS/MODBUS Adapter

Value

0.1A
0.1kWh
1
0.1kW
0.1kW
0.01
0.1A
0.01
0.01

0.1A
0.1kWh
1
0.1kW
0.1kW
0.01
0.1A
0.01
0.01

User Manual

Chapter 3 Protocol Text


ID
1153
1154
1155
1156
1157

1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937

1999

Byte

2
2

Item
SPM Branch 2 reserved
SPM Branch 2 reserved
SPM Branch 2 reserved
SPM Branch 2 reserved
SPM Branch 2 reserved

SPM Branch 54 current


SPM Branch 54 power (kWh)
SPM Branch 54 switch status
SPM Branch 54 active power
SPM Branch 54 apparent power
SPM Branch 54 THDi
SPM Branch 54 rated current
SPM Branch 54 load ratio
SPM Branch 54 power factor
SPM Branch 54 reserved
SPM Branch 54 reserved
SPM Branch 54 reserved
SPM Branch 54 reserved
SPM Branch 54 reserved
SPM Branch 54 reserved

Reserved

33

Value

0.1A
0.1kWh
1
0.1kW
0.1kW
0.01
0.1A
0.01
0.01

3.10 Protocol Text Of NXr / APM300/EPM UPSs


1. UPS basic information
ID

Byte

1000 ~ 1004

10

Item

Value

UPS name

HR331500
0x0201 to V2.01

1005

UPS firmware release

1006 ~ 1015

20

Manufacturer

EmersonNetworkPower

1019

Adapter firmware release

0x0201 to V2.01

2. UPS alarm data


ID

Bit
Bit 0

Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7

Item
UPS general alarm flag bit
Modbus card/dry contactor card communication
failure flag bit
Reserved
Inverter synchronous/asynchronous
Mains voltage
Rectifier status
Inverter status
Bypass conditions (voltage or frequency)

1030
Bits
10/9/8

Battery 1 status

Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Functional module 1 failure


Functional module 2 failure
Functional module 3 failure
Functional module 4 failure
Functional module 5 failure

UPS JBUS/MODBUS Adapter

Value

0: Normal; 1: Alarm
0: Normal; 1: Failure

0: Synchronous; 1: Asynchronous
0: Synchronous; 1: Asynchronous
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Excessive
000: Normal
001: Below the lower limit (power-off point)
010: Above the upper limit (excessive voltage)
011: No battery
100: Pre-alarm
101: Reverse batteries
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

User Manual

34

Chapter 3 Protocol Text


ID

1031

1032

1033

Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5

Item
Functional module 6 failure
Functional module 7 failure
Functional module 8 failure
Functional module 9 failure
Functional module 10 failure
LBS abnormal

Bit 7/6

Keyboard failure or model capacity invalid

Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6

Fan failure
Environmental temperature over-high
Emergency power off
Bypass thyristor failure
Bypass phase sequence reverse
Bypass over-current failure
Bypass abnormal power off
Bypass switching number limit
Failure of module combining board
Failure of module combining cable
Communication failure of module combining
Auxiliary power 2 power off
Contactor power board 1 failure
Contactor power board 2 failure
Redundant fan power failure

Bit 8/7

BCB access status

Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Battery 1 contactor failure


Battery 2 contactor failure
Battery 1 converter failure
Battery 2 converter failure
Battery 1 converter over-current
Battery 2 converter over-current
Battery 1 converter over-temperature
Battery 2 converter over-temperature
Battery 1 charger failure
Battery 2 charger failure

Bit 4/3

Battery 1 life

Bit 6/5

Battery 2 life

Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery 1 temperature over-high


Battery 1 temperature over-high
Battery 1 grounding failure
Battery 1 grounding failure
Master channel frequency abnormal
Balance inductor over-temperature
Input inductor over-temperature
Rectifier over-temperature
Balance circuit failure

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
00: Normal; 01: Keyboard failure
10: Model capacity invalid
0: Normal; 1: Failure
0: Normal; 1: Over-high
0: Normal; 1: Power off
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
00: BCB not accessed; 01: BCB closed
03: BCB disconnected
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure
00: Normal; 01: Battery to be replaced
10: Battery life ended
00: Normal; 01: Battery to be replaced
10: Battery life ended
0: Normal; 1: Over-high
0: Normal; 1: Over-high
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Excessive
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure

User Manual

Chapter 3 Protocol Text


ID

1034

Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Bit 3

1035

1036

Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bits
1115

Item
Balance inductor over-current
Master fuse broken
Auxiliary power 1 power-off
Master channel phase sequence reverse
Rectifier over-current
Software start failure
Inversion inductor over-temperature
Inductor over-temperature
Inversion thyristor failure
User operation error
Output fuse broken
Single unit output overload
Combined system overload
Single unit overload timeout
AC output over-voltage
Inverter over-current
Turning to bypass due to load impact
Failure of current sharing in combined units
Abnormal power-off of bus
Turning to bypass due to request by neighbor
system
DC bus over-voltage failure
Rectifier communication failure
Inverter communication failure
Output DC excess failure
Combined system battery pre-alarm failure
Input zero-lacking failure
Inversion contactor failure
Input contactor failure
Input current abnormal
Output voltage abnormal
Input current excessive
Bypass over-temperature
System Bypass STS fail
Input TX Overtemp
Input TX Fan fault
Bp cabinet TX Overtemp
Top-outlet Fan fault
Loss of redundancy
Capacity Exceeded
Functional module 11 failure
Functional module 12 failure
Bypass not available
Equalize charge overtime

Value
0: Normal; 1: Over-current
0: Normal; 1: Broken
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Error
0: Normal; 1: Broken
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout
0: Normal; 1: Over-voltage
0: Normal; 1: Over-current
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure

Reserved

UPS JBUS/MODBUS Adapter

User Manual

35

36

Chapter 3 Protocol Text


3. UPS status data
ID

1040

Bit

1042

Value
00: UPS power supply; 01: Bypass power
supply
10: No power supply
0: In self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non-charging status
0: Power-off; 1: Power-on
00: Master channel input, rectifier started
01: Battery input, rectifier started
10: Combined input, rectifier started
11: No input from master channel or batteries
0: Generator accessed; 1: Generator not
accessed
0: Disconnected; 1: Closed

Bit 1/0

Power supply mode

Bit 2

Battery 1 self-check

Bit 4/3

Battery 1 average charge/floating charge

Bit 5

Integrated equipment power-on/off

Bit 7/6

Rectifier power supply status

Bit 8

Integrated generator access event

Bit 9

Bit 11
Bit 12

Integrated equipment input air breaker status


Integrated equipment maintenance bypass air
breaker status
Integrated equipment bypass air breaker status
Integrated equipment output air breaker status

Bit
15/14/13

Integrated equipment revolving air breaker


status

Bits 2/1/0

Rack combined system power supply status

Bit 3

Battery 2 battery self-check

Bit 5/4

Battery 2 floating / average charge status

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Module 1 online or offline


Module 2 online or offline
Module 3 online or offline
Module 4 online or offline
Module 5 online or offline
Module 6 online or offline
Module 7 online or offline
Module 8 online or offline
Module 9 online or offline
Module 10 online or offline

0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass
100: Maintenance
000: No power supply
001: Bypass power supply
010: Mains supply
011: Battery inversion power supply
100: United power supply
101: Output prohibited
0: in self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non charge
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline

Bit 0

Frequency Converter Mode or Normal Mode

0Normal Mode1Frequency Converter Mode

Bit 1

ECO Mode or Normal Mode

0Normal Mode1ECO Mode

Bit 2
Bit 3

Module 11 online or offline


Module 12 online or offline

0: Online; 1: Offline
0: Online; 1: Offline

Bit 215

Reserved

Bit 10

1041

Item

0: Disconnected; 1: Closed

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056

Byte

2
2
2
2
2
2
2

Item
Input phase voltage A
Input phase voltage B
Input phase voltage C
Output phase voltage A
Output phase voltage B
Output phase voltage C
Output phase current A

UPS JBUS/MODBUS Adapter

Value

0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.1A

User Manual

Chapter 3 Protocol Text


ID
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Output phase current B
Output phase current C
DC input voltage (Battery 1 voltage)
Output frequency (consistency in three phases)
Input cable voltage AB
Input cable voltage BC
Input cable voltage CA
Input phase current A
Input phase current B
Input phase current C
Input frequency (consistency in three phases
Phase A input power factor
Phase B input power factor
Phase C input power factor
Bypass phase voltage A
Bypass phase voltage B
Bypass phase voltage C
Bypass frequency
Phase A output power factor
Phase B output power factor
Phase C output power factor
Phase A output peak ratio
Phase B output peak ratio
Phase C output peak ratio
Phase A output active power
Phase B output active power
Phase C output active power
Phase A output reactive power
Phase B output reactive power
Phase C output reactive power
Phase A output apparent power
Phase B output apparent power
Phase C output apparent power
Battery backup time
Positive battery voltage
Positive battery current
Negative battery voltage
Negative battery current
Battery aging coefficient
Battery temperature
Environmental temperature

Value

0.1A
0.1A
0.1V
0.01Hz
0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.01Hz
0.01
0.01
0.01
0.1V
0.1V
0.1V
0.01Hz
0.01
0.01
0.01
0.01
0.01
0.01
0.01kW
0.01kW
0.01kW
0.01kVA
00.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01kVA
Minute
0.1V
0.1A
0.1V
0.1A
0.1
0.1C
0.1C

3.11 Protocol Text Of APL(NXp) UPS


1. UPS basic information
ID

1000 ~ 1004

Byte

10

Item

Value

UPS name

MR33 0300
0x0201 to V2.01

1005

UPS firmware release

1006 ~ 1015

20

Manufacturer

EmersonNetworkPower

1019

Adapter firmware release

0x0201 to V2.01

UPS JBUS/MODBUS Adapter

User Manual

37

38

Chapter 3 Protocol Text


2. UPS alarm data
ID

Bit
Bit 0

Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7

Item
UPS general alarm flag bit
Modbus card/dry contactor card communication
failure flag bit
Reserved
Inverter synchronous/asynchronous
Mains voltage
Rectifier status
Inverter status
Bypass conditions (voltage or frequency)

Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4

Functional module 1 failure


Functional module 2 failure
Functional module 3 failure
Functional module 4 failure
Functional module 5 failure
Functional module 6 failure
Functional module 7 failure
Functional module 8 failure
Functional module 9 failure
Functional module 10 failure
LBS abnormal
Keyboard failure or model capacity
invalid(Reserved)
Bypass SCR Fan abnormal
Environmental temperature over-high(Reserved)
Emergency power off
Bypass thyristor failure
Bypass phase sequence reverse
Bypass over-current failure
Bypass abnormal power off
Bypass switching number limit
Failure of module combining board (Reserved)
Abnormal of module combining cable
Communication abnormal of module combining
Auxiliary power 2 power off (Reserved)
Discharge current-limiting

Bit 5

Contactor power board 2 failure(Reserved)

0: Normal; 1: Failure

Bit 6

Redundant fan power failure

Bit 8/7

BCB access status(Reserved)

Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery contactor failure(Reserved)


Battery 2 contactor failure(Reserved)
Battery converter failure
Battery 2 converter failure(Reserved)
Battery converter over-current(Reserved)
Battery 2 converter over-current(Reserved)
Battery converter over-temperature(Reserved)

0: Normal; 1: Abnormal
00: BCB not accessed; 01: BCB closed
03: BCB disconnected
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Over-temperature

Bits
10/9/8

Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 7/6

1032

0: Normal; 1: Failure

0: Synchronous; 1: Asynchronous
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
000: Normal
001: Below the lower limit (power-off point)
010: Above the upper limit (excessive
voltage)( Reserved)
011: No battery
100: Pre-alarm
101: Reverse batteries
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
00: Normal; 01: Keyboard failure
10: Model capacity invalid
0: Normal; 1: Abnormal
0: Normal; 1: Over-high
0: Normal; 1: Power off
0: Normal; 1: Failure
0: Normal; 1: Phase sequence reverse
0: Normal; 1: Over-current
0: Normal; 1: Abnormal Power off
0: Normal; 1: Limit
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Limit

1030

1031

Value

0: Normal; 1: Alarm

Battery status

UPS JBUS/MODBUS Adapter

User Manual

Chapter 3 Protocol Text


ID

1033

1034

Bit
Bit 0
Bit 1
Bit 2

Item
Battery 2 converter over-temperature(Reserved)
Battery charger failure
Battery 2 charger failure (Reserved)

Bit 4/3

Battery to be replaced

Bit 6/5

Battery 2 life (Reserved)

Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2

Battery temperature over-high


Battery 2 temperature over-high (Reserved)
Battery grounding failure
Battery 2 grounding failure (Reserved)
Master channel frequency abnormal
Balance inductor over-temperature
Input inductor over-temperature
Module over-temperature (Reserved)
Balance circuit failure (Reserved)
Balance inductor over-current (Reserved)
Master fuse broken
Auxiliary power power-off
Master channel phase sequence reverse
Bridge short-current (Reserved)
Software start failure
Inversion inductor over-temperature(Reserved)
Inductor over-temperature (Reserved)
Inversion thyristor failure (Reserved)
User operation error
Output fuse broken
Single unit output overload
Combined system overload
Single unit overload timeout
AC output over-voltage (Reserved)
Inverter over-current (Reserved)
Turning to bypass due to load impact
Failure of current sharing in combined units
Abnormal power-off of bus
Turning to bypass due to request by neighbor
system
DC bus over-voltage failure
Rectifier communication failure
Communication failure (Reserved)
Output DC excess failure (Reserved)
Combined system battery pre-alarm
failure(Reserved)
Input zero-lacking failure
Inversion contactor failure
Input contactor failure
Input current abnormal
Output voltage abnormal
Input current excessive
Bypass over-temperature

Bit 3

1035

Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure
00: Normal; 01: Battery to be replaced
10: Battery life ended
00: Normal; 01: Battery to be replaced
10: Battery life ended
0: Normal; 1: Over-high
0: Normal; 1: Over-high
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Broken
0: Normal; 1: Power off
0: Normal; 1: Phase sequence reverse
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Error
0: Normal; 1: Broken
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout
0: Normal; 1: Over-voltage
0: Normal; 1: Over-current
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

User Manual

39

40

Chapter 3 Protocol Text


ID

Bit
Bit 0

Bit 1
Bit 2

1036

1037

Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bits 4~15

Item
Thyristor failure in neighboring unit
External input isolated transformer
over-temperature(Reserved)
External input isolated transformer fan
failure(Reserved)
Bypass transformer over-temperature(Reserved)
IGBT drv. cable fault
SCR fan abnormal
Charger fan abnormal
SubBlock1 fan abnormal
SubBlock2 fan abnormal
SubBlock3 fan abnormal
Auxpower fan abnormal
Rec. ind. fan abnormal
Inv. conta. power fail
SubBlock1 over-current
SubBlock2 over-current
SubBlock3 over-current
Para.connect. abnormal
Byp.fan power abnormal
Byp. drv. cable fault
SubBlock1 overtemp
SubBlock2 overtemp
SubBlock3 overtemp
SCR overtemp
Charger overtemp
Batt. port short
Byp.aux.pwr.fan abnor
Inv aux.conta.1 abnor
Inv aux.conta.2 abnor
Battery room alarm
BCB status abnormal
Byp. neutral lost
Bypass in charge
BCB1 status abnormal
BCB2 status abnormal
BCB3 status abnormal
BCB4 status abnormal
Reserved

UPS JBUS/MODBUS Adapter

Value

0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: No charge;1: In charge
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

User Manual

Chapter 3 Protocol Text

41

3. UPS status data


ID

1040

Bit

Bit 1/0

Power supply mode

Bit 2

Battery self-check

Bit 4/3

Battery average charge/floating charge

Bit 5

Integrated equipment power-on/off

Bit 7/6

Rectifier power supply status

Bit 8

Integrated generator access event

Bit 9

Bit 11
Bit 12

Integrated equipment input air breaker status


Integrated equipment maintenance bypass air
breaker status
Integrated equipment bypass air breaker status
Integrated equipment output air breaker status

Bit
15/14/13

Integrated equipment revolving air breaker


status (Reserved)

Bits 2/1/0

Rack combined system power supply status

Bit 3

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery 2 battery self-check(Reserved)


Battery 2 floating / average charge
status(Reserved)
Module 1 online or offline
Module 2 online or offline
Module 3 online or offline
Module 4 online or offline
Module 5 online or offline
Module 6 online or offline
Module 7 online or offline
Module 8 online or offline
Module 9 online or offline
Module 10 online or offline

Bit 1/0

BCB Status

Bit 3/2

BCB 1 Status

Bit 5/4

BCB 2 Status

Bit 7/6

BCB 3 Status

Bit 9/8

BCB 4 Status

Bit 10
Bit 11
Bit 12
Bit 13

Output sw.1 Status


Output sw.2 Status
Input sw.1 Status
Input sw.2 Status

Bit 10

Bit 5/4
1041

1042

Item

UPS JBUS/MODBUS Adapter

Value
00: UPS power supply; 01: Bypass power
supply
10: No power supply
0: In self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non-charging status
0: Power-off; 1: Power-on
00: Master channel input, rectifier started
01: Battery input, rectifier started
10: Combined input, rectifier started(Reserved)
11: No input from master channel or batteries
0: Generator accessed; 1: Generator not
accessed
0: Disconnected; 1: Closed

0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass
100: Maintenance
000: No power supply
001: Bypass power supply
010: Mains supply
011: Battery inversion power supply
100: United power supply
101: Output prohibited
0: in self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non charge
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
00: BCB not connected; 01: BCB open; 10:
BCB close
00: BCB not connected; 01: BCB open; 10:
BCB close
00: BCB not connected; 01: BCB open; 10:
BCB close
00: BCB not connected; 01: BCB open; 10:
BCB close
00: BCB not connected; 01: BCB open; 10:
BCB close
0 :Close; 1: Open
0 :Close; 1: Open
0 :Close; 1: Open
0 :Close; 1: Open

User Manual

42

Chapter 3 Protocol Text


4. UPS analog data
ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Input phase voltage A
Input phase voltage B
Input phase voltage C
Output phase voltage A
Output phase voltage B
Output phase voltage C
Output phase current A
Output phase current B
Output phase current C
DC input voltage (Battery 1 voltage)
Output frequency (consistency in three phases)
DC input voltage (Battery 2 voltage)(Reserved)
Input cable voltage AB
Input cable voltage BC
Input cable voltage CA
Input phase current A
Input phase current B
Input phase current C
Input frequency (consistency in three phases)
Phase A input power factor
Phase B input power factor
Phase C input power factor
Bypass phase voltage A
Bypass phase voltage B
Bypass phase voltage C
Bypass frequency
Input capacitance current A
Input capacitance current B
Input capacitance current C
Output capacitance current A
Output capacitance current B
Output capacitance current C
Phase A output power factor
Phase B output power factor
Phase C output power factor
Phase A output peak ratio
Phase B output peak ratio
Phase C output peak ratio
Phase A output active power
Phase B output active power
Phase C output active power
Phase A output reactive power
Phase B output reactive power
Phase C output reactive power
Phase A output apparent power
Phase B output apparent power
Phase C output apparent power
Phase A output load level
Phase B output load level
Phase C output load level
Battery backup time
Positive battery voltage
Positive battery current
Negative battery voltage
Negative battery current
Battery aging coefficient
Battery temperature

UPS JBUS/MODBUS Adapter

Value

0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.1V
0.01Hz
0.1V
0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.01Hz
0.01
0.01
0.01
0.1V
0.1V
0.1V
0.01Hz
0.1A
0.1A
0.1A
0.1A
0.1A
0.1A
0.01
0.01
0.01
0.01
0.01
0.01
0.01kW
0.01kW
0.01kW
0.01kVA
00.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01
0.01
0.01
Minute
0.1V
0.1A
0.1V
0.1A
0.1
0.1C

User Manual

Chapter 3 Protocol Text


ID
1107
1108

Byte

2
2

Item
Environmental temperature
Unit environmental temperature

Value

0.1C
0.1C

3.12 ITA/NXC 30/40k UPS


1. UPS basic information
ID

Byte

1000 ~ 1004

10

Item

Value

UPS name

XC33 0300
0x0201 to V2.01

1005

UPS firmware release

1006 ~ 1015

20

Manufacturer

EmersonNetworkPower

1019

Adapter firmware release

0x0201 to V2.01

2. UPS alarm data


ID

Bit
Bit 0

Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 8/7

Item
UPS general alarm flag bit
Modbus card/dry contactor card communication
failure flag bit
Reserved
Inverter synchronous/asynchronous
Mains voltage
Rectifier status
Inverter status
Bypass conditions (voltage or frequency)

1030
Bits
11/10/9

Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 7/6
1031

Bit 9/8
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery status

Functional module 1 failure


Functional module 2 failure
Functional module 3 failure
Functional module 4 failure
Functional module 5 failure
Functional module 6 failure
Functional module 7 failure
Functional module 8 failure
Functional module 9 failure
Functional module 10 failure
LBS abnormal
Keyboard failure or model capacity
invalid(Reserved)
Bypass SCR Fan abnormal
Environmental temperature over-high(Reserved)
Emergency power off
Bypass thyristor failure
Bypass phase sequence reverse
Bypass over-current failure

UPS JBUS/MODBUS Adapter

Value

0: Normal; 1: Alarm
0: Normal; 1: Failure

0: Synchronous; 1: Asynchronous
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
000: Normal
001: Below the lower limit (power-off point)
010: Above the upper limit (excessive
voltage)( Reserved)
011: No battery
100: Pre-alarm
101: Reverse batteries
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 01: Active; 10:Abnormal
00: Normal; 01: Keyboard failure
10: Model capacity invalid
0: Normal; 1: Abnormal
0: Normal; 1: Over-high
0: Normal; 1: Power off
0: Normal; 1: Failure
0: Normal; 1: Phase sequence reverse
0: Normal; 1: Over-current

User Manual

43

44

Chapter 3 Protocol Text


ID

1032

1033

1034

Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 10/9
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 6/5

Item
Bypass abnormal power off
Bypass switching number limit
Failure of module combining board(Reserved)
Abnormal of module combining cable(Reserved)
Communication abnormal of module combining
Auxiliary power 2 power off(Reserved)
Contactor power board 1 failure(Reserved)
Contactor power board 2 failure(Reserved)
Redundant fan power failure(Reserved)
BCB status
Battery contactor failure(Reserved)
Battery 2 contactor failure(Reserved)
Battery converter failure
Battery 2 converter failure(Reserved)
Battery converter over-current(Reserved)
Battery 2 converter over-current(Reserved)
Battery converter over-temperature(Reserved)
Battery 2 converter over-temperature(Reserved)
Battery charger failure
Battery 2 charger failure(Reserved)
Battery to be maintenance

Bit 8/7

Battery 2 life (Reserved)

Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery temperature over-high


Battery 2 temperature over-high(Reserved)
Battery grounding failure(Reserved)
Battery 2 grounding failure(Reserved)
Master channel frequency abnormal
Balance inductor over-temperature(Reserved)
Input inductor over-temperature(Reserved)
Rectifier over-temperature
Balance circuit failure(Reserved)
Balance inductor over-current(Reserved)
Master fuse broken(Reserved)
Auxiliary power power-off
Master channel phase sequence reverse
Rectifier over-current(Reserved)
Software start failure
Inversion inductor over-temperature(Reserved)
Inductor over-temperature(Reserved)
Inversion thyristor failure
User operation error
Output fuse broken
Single unit output overload
Combined system overload
Single unit overload timeout

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Abnormal Power off
0: Normal; 1: Limit
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Over-current
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure
00: Normal; 01: Battery to be maintenance
00: Normal; 01: Battery to be replaced
10: Battery life ended
0: Normal; 1: Over-high
0: Normal; 1: Over-high
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Abnormal
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Over-current
0: Normal; 1: Broken
0: Normal; 1: Power off
0: Normal; 1: Phase sequence reverse
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Error
0: Normal; 1: Broken
0: Normal; 1: Overload
0: Normal; 1: Overload
0: Normal; 1: Overload timeout

User Manual

Chapter 3 Protocol Text


ID

Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4

Bit 5

1035

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit15
Bit 0
Bit 1
Bit 2
Bit 3

1036
Bit 4
Bit 5
Bit 6
Bits 15-7

Item
AC output over-voltage(Reserved)
Inverter over-current(Reserved)
Turning to bypass due to load impact
Failure of current sharing in combined units
Abnormal power-off of bus
Turning to bypass due to request by neighbor
system
DC bus over-voltage failure
Rectifier communication failure(Reserved)
Communication failure
Output DC excess failure(Reserved)
battery pre-alarm failure(Reserved)
Input zero-lacking failure
Inversion contactor failure(Reserved)
Input contactor failure(Reserved)
Input current abnormal
Output voltage abnormal
Input current excessive
Bypass over-temperature(Reserved)
Thyristor failure in neighboring unit
External input isolated transformer
over-temperature(Reserved)
External input isolated transformer fan
failure(Reserved)
Input Feedback
Discharge current limit
Reserved

45

Value
0: Normal; 1: Over-voltage
0: Normal; 1: Over-current
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure

0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Failure
0: Normal; 1: Over-temperature
0: Normal; 1: Failure
0: Normal; 1: Failure

3. UPS status data


ID

1040

Bit

Item

Bit 1/0

Power supply mode

Bit 2

Battery self-check

Bit 4/3

Battery average charge/floating charge

Bit 5

Integrated equipment power-on/off

Bit 7/6

Rectifier power supply status

Bit 8

Integrated generator access event

Bit 9

Bit 11
Bit 12

Integrated equipment input air breaker status


Integrated equipment maintenance bypass air
breaker status
Integrated equipment bypass air breaker status
Integrated equipment output air breaker status

Bit
15/14/13

Integrated equipment revolving air breaker


status(Reserved)

Bit 10

UPS JBUS/MODBUS Adapter

Value
00: UPS power supply; 01: Bypass power
supply
10: No power supply
0: In self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non-charging status
0: Power-off; 1: Power-on
00: Master channel input, rectifier started
01: Battery input, rectifier started
10: Combined input, rectifier started(Reserved)
11: No input from master channel or batteries
0: Generator accessed; 1: Generator not
accessed
0: Disconnected; 1: Closed

0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass
100: Maintenance

User Manual

46

Chapter 3 Protocol Text


ID

Bit

Bits 2/1/0

Rack combined system power supply status

Bit 3

Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Battery 2 battery self-check(Reserved)


Battery 2 floating / average charge
status(Reserved)
Module 1 online or offline
Module 2 online or offline
Module 3 online or offline
Module 4 online or offline
Module 5 online or offline
Module 6 online or offline
Module 7 online or offline
Module 8 online or offline
Module 9 online or offline
Module 10 online or offline

Value
000: No power supply
001: Bypass power supply
010: Mains supply
011: Battery inversion power supply
100: United power supply
101: Output prohibited
0: in self-check; 1: Not in self-check
00: Floating charge; 01: Average charge
10: Non charge
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline
0: Online; 1: Offline

Bit 0

ECO mode Status

00normal mode01:ECO mode

Bit 2/1

BCB Status

00: BCB not connected; 01: BCB close; 10:


BCB open

Bit3 15-3

Reserved

Bit 5/4
1041

1042

Item

4. UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Input phase voltage A
Input phase voltage B
Input phase voltage C
Output phase voltage A
Output phase voltage B
Output phase voltage C
Output phase current A
Output phase current B
Output phase current C
DC input voltage (Battery 1 voltage)
Output frequency (consistency in three phases)
Reserved
Reserved
Reserved
Reserved
Input cable voltage AB
Input cable voltage BC
Input cable voltage CA
Input phase current A
Input phase current B
Input phase current C
Input frequency (consistency in three phases)
Phase A input power factor
Phase B input power factor
Phase C input power factor
Bypass phase voltage A
Bypass phase voltage B
Bypass phase voltage C
Bypass frequency
Phase A output power factor
Phase B output power factor
Phase C output power factor

UPS JBUS/MODBUS Adapter

Value

0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.1V
0.01Hz

0.1V
0.1V
0.1V
0.1A
0.1A
0.1A
0.01Hz
0.01
0.01
0.01
0.1V
0.1V
0.1V
0.01Hz
0.01
0.01
0.01

User Manual

Chapter 3 Protocol Text


ID
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Phase A output peak ratio
Phase B output peak ratio
Phase C output peak ratio
Phase A output active power
Phase B output active power
Phase C output active power
Phase A output reactive power
Phase B output reactive power
Phase C output reactive power
Phase A output apparent power
Phase B output apparent power
Phase C output apparent power
Phase A output load level
Phase B output load level
Phase C output load level
Battery backup time
Positive battery voltage
Positive battery current
Negative battery voltage
Negative battery current
Battery aging coefficient
Battery temperature
Environmental temperature

Value

0.01
0.01
0.01
0.01kW
0.01kW
0.01kW
0.01kVA
00.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01kVA
0.01
0.01
0.01
Minute
0.1V
0.1A
0.1V
0.1A
0.1
0.1C
0.1C

3.13 Protocol Text Of APS UPS


1. UPS basic information
ID

Byte

1000 ~ 1004

10

Item

Value

UPS name

EgPA1R002002

1005

UPS firmware release

0x0201 to V2.01

1006 ~ 1015

20

Manufacturer

EmersonNetworkPower

1019

Adapter firmware release

0x0201 to V2.01

2. UPS alarm data


ID

Byte

Bit 0
Bit 1
Bit 2
Bit 3

1030

Bit 4
Bit 5
Bit 6
Bit 7
Bits 10/9/8
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15

Item
UPS general alarm flag bit
Modbus card/dry contactor card
communication failure flag bit
Reserved
Inverter
synchronous/asynchronous(nonsupport)
Mains voltage(nonsupport)
Rectifier status(nonsupport)
Inverter status(nonsupport)
Bypass conditions (voltage or frequency)
(nonsupport)
Battery voltage abnormal nonsupport)
Input phase A not qualified
Input phase B not qualified
Input phase C not qualified
PM fan failure
PM lock lever in remove position

UPS JBUS/MODBUS Adapter

Value

0: Normal; 1: Alarm
0: Normal; 1: Failure

0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

User Manual

47

48

Chapter 3 Protocol Text


ID

1031

1032

1033

Byte
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bits 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bits 10
Bit 11
Bit 12
Bit 13
Bits 14
Bit 15

Item
PM fault
PM short circuit
PM warning
Insufficient capacity to start
PM over load
PM over temperature warning
PM over temperature shutdown
Output off- Overload,bypass abn
Short circuit shutdown
Bypass monitor board fault
Guaranteed shutdown
transformer over temp shutdown
EOD shutdown
transformer over temperature
Output off,voltage is not zero
Reserved
Bypass control board alarm
Frame fan fault
Bypass abnormal
Transformer fan fault
Battery module voltage low
Bp ctr locker in remove position
Bp monitor board fault
Shutdown on manual bypass
Output off- bypass unavailable
Bp mnt locker in remove position
CM power source is not qualified
CM alarm
CM locker in remove position
CM fan fault
CM over temperature
Reserved
CM fault
CM over temperature and shutdown
No matching battery module
Load exceeds BM capacity
Battery cabinet not connected
Battery module alarm
BM locker in Remove position
Battery module over temperature
Low battery warning
Battery test failure
Low battery for battery test
Battery temperature imbalance
BM over temperature and shutdown
Battery module fault
Starting battery test
Stoped battery test

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

User Manual

Chapter 3 Protocol Text


ID

1034

1035

1036

Byte
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit13
Bit 14
Bit 15
Bit 0
Bit 1
Bit 2
Bit 3
Bits 4-15

Item
BM use exceed 5 years of age
Output pending
All PMs are not ready
Communication output off
UPS is operating on battery
Battery-to-utility transition
UPS's load power is on
Load off from user interface
Operating on Inverter
On manual bypass
Time to check the fan filters
Acknowledged filter reminder
Acknowledged batt test results
Load off due to shutdown on batt
Output must be off
Power module redundancy alarm
Output exceeds max load setting
System alarm
EPO shutdown
Overload cleared
NO battery module are ready
L1 L2 reversed
Battery reversed
Input fuse disconnection
L1 L2 input current imbalance
Frame fault
Ext batt over temperature
No external batt
Load exceeds Ext batt capacity
Ext batt high voltage
Ext batt low voltage
Ext batt mode BM exit
Rear rocker switch turned off
Input neutral is not connected
Bypass jumper error
Operating on Bypass
Reserved

UPS JBUS/MODBUS Adapter

Value
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal
0: Normal; 1: Abnormal

User Manual

49

50

Chapter 3 Protocol Text


3. UPS status data
ID

1040

Byte

Output supply status

Bit 3/2

Input supply status

Bits 6/5/4

Battery status

Bit7
Bits 8-15

CM status
Reserved

Bit 8

Integrated generator access event

Bit 9

Integrated equipment input air breaker status


Integrated equipment maintenance bypass air
breaker status
Integrated equipment bypass air breaker status
Integrated equipment output air breaker status

Bit 11
Bit 12

1046

Value
00: UPS power supply;
01: Bypass power supply
10: No power supply

Bits 1/0

Bit 10

1045

Item

00unity supply;01:battery supply;


10:union supply; 11:no power supply
000:wait ing charge;
001: Floating charge;
010: Average charge;
011:battery test
100:blank
0: on; 1:off

Bits 15/14/13

Integrated equipment revolving air breaker


status

Bits 1
Bit 2
Bits3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8-15
Bit 0
Bit 1
Bit 2
Bit 3

Input dry contactor state 1


Input dry contactor state 2
Input dry contactor state 3
Input dry contactor state 4
Input dry contactor state 5
Input dry contactor state 6
Input dry contactor state 7
Reserved
UPS input state
Battery state
UPS output state
UPS state

Bits 415

Reserved

0: Generator accessed; 1: Generator


not accessed
0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
0: Disconnected; 1: Closed
000: Closed
001: Under test
010: Normal
011: Bypass
100: Maintenance
0:off ;1:close
0:off ;1:close
0:off ;1:close
0:off ;1:close
0:off ;1:close
0:off ;1:close
0:off ;1:close
0:normal;1:battery supply
0:normal;1:battery voltage low
0:normal;1 bypass output or no output
0:normal;1:fault

4.UPS analog data


ID
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item

Value

L-N voltage A
L-N voltage B
L-N voltage C
L-N voltage A
L-N voltage B
L-N voltage C
L-N current A
L-N current B
L-N current C
Battery voltage
Output frequency
Reserved
Reserved
Reserved
Input frequency
Input power factor A
Input power factor B

UPS JBUS/MODBUS Adapter

0.01 Volt
0.01 Volt
0.01 Volt
0.01 Volt
0.01 Volt
0.01 Volt
0.01 Ampere
0.01 Ampere
0.01 Ampere
0.01 Volt
0.01 Hz

0.01Hz
0.01
0.01

User Manual

Chapter 3 Protocol Text


ID
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1120
1121
1122
1123
1124
1125
1126
1127

Byte

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Item
Input power factor C
L-N current A
L-N current B
L-N current C
Reserved
Bypass voltage A
Bypass voltage B
Bypass frequency A
Bypass frequency B
Reserved
Battery string count
Remain time
Battery capacity
Battery temperature
Discharge count
Discharge hour
Reserved
External battery cabinet count
Fault BM count
Alarm BM count
CM installed count
Fault CM count
Alarm CM count
Reserved
Reserved
Output power factor A
Output power factor B
System Output apparent power A
System Output apparent power B
Output real power A
Output real power B
Load rate A
Load rate B
PM online count
Alarm PM count
Fault PM count
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
dry contactor card analog 1
dry contactor card analog 2
dry contactor card analog 3
dry contactor card analog 4
dry contactor card analog 5
dry contactor card analog 6
dry contactor card analog 7
dry contactor card analog 8

UPS JBUS/MODBUS Adapter

User Manual

Value

0.01
0.01
0.01
0.01
0.1 Volt
0.1 Volt
0.01 Hz
0.01 Hz

Minute
1%
0.1
0.1Hour

0.01
0.01
0.001KVA
0.001 KVA
0.001KW
0.001KW
0.1
0.1

Determined by the user settings


Determined by the user settings
Determined by the user settings
Determined by the user settings
Determined by the user settings
Determined by the user settings
Determined by the user settings
Determined by the user settings

51

52

Chapter 3 Protocol Text

3.14 Protocol Text Of GXE 1-10kVA UPS


1. UPS basic information
ID

Byte

1000~1004

10

1005
1006~1015
1019

2
20
2

Item
UPS name
UPS firmware release
Manufacturer
Adapter firmware release
UPS name

Value

R/T UPS name: UHE1T0100


0x010B corresponds to V1.11
"EmersonNetworkPower"
0x010B corresponds to V1.11

2. UPS alarm data


ID

1030

1031

1032

Bit

Item

Value

Bit 0

UPS alarm flag

0: Normal; 1: Alarm

Bit 1

Adapter communication fault flag

0: Normal; 1: Fault

Bit 2

Not defined

Bit 3

Synchronization/Unsynchronization

0: Normal;
1: Unsynchronization

Bits 5/4

Mains status

00: Normal;
01: Abnormal

Bit 6

Rectifier status

0: Normal; 1: Fault

Bit 7

Inverter status

0: Normal; 1: Fault

Bits 9/8

Bypass status

00: Normal; 01: Abnormal

Bits 11/10

Battery voltage status

00: Normal
01: Below lower limit
10: Above upper limit
11: Fault

Bit 12

Heatsink status

0: Normal; 1: Over temperature

Bit 13

Fan status

0: Normal; 1: Abnormal

Bits 15/14

Neutral line missing

00: Normal
01: Abnormal
10: nonsupport

Bit 0

Bus voltage status

0: Normal; 1: Abnormal

Bit 1

Charge module status

0: Normal; 1: Fault

Bit 2

Battery EOD status

0: Normal; 1: Battery EOD

Bit 3

Auxiliary supply status

0: Normal; 1: Fault

Bit 4

Output overload status

0: Normal; 1: Overload

Bit 5

Output short circuit status

0: Normal; 1: Short circuit

Bit 6

Overload time-out

0: Normal; 1: Time-out

Bit 7

Boost charge status

0: Normal; 1: Fault

Bit 8

Parallel cable status

0: Normal; 1: Fault

Bits 10/9

Parallel Address Error

00: Normal
01: Alarm
10: No Parallel System

Bits 12/11

Parallel unit communication status

00: Normal
01: Alarm
10: No Parallel System

Bits 14/13

System Overload

00: Normal
01: Alarm
10: No Parallel System

Bit 15

Not defined

Bits 1/0

EPO

Bit 2

No Battery

0: Normal; 1: Alarm

Bit 3

Battery Reversed

0: Normal; 1: Alarm

Bits 15~4

Not defined

UPS JBUS/MODBUS Adapter

00: Normal
01: EPO
10: nonsupport

User Manual

Chapter 3 Protocol Text


3. UPS status data
ID

Bit

Item

Value

Operation mode

00: Neither Normal nor Battery mode


01: Normal mode
10: Battery mode
11: Bypass mode

Bits 3/2

Battery charge state

00: Float charge


01: Boost charge
10: Neither charge nor discharge
11: Discharge

Bit 4

Battery self-test state

0: Not under test


1: Under test

Bit 5

Battery self-test enable

0: Enabled
1: Not enabled

Bit 6

Battery low pre-alarm

0: Battery voltage normal


1: Battery low pre-alarm

Bit 7

Switch-on or switch-off

0: On; 1: Off

Bits 15~8

Not defined

Bits 1/0

1040

4. UPS analog data


ID

Byte

1050

1051
1052

Item

Value

AC input phase voltage A

22000 corresponds to 220.0Vac

AC input phase voltage B

22000 corresponds to 220.0Vac

AC input phase voltage C

22000 corresponds to 220.0Vac

1053

AC output phase voltage

22000 corresponds to 220.0Vac

1054

AC output current

10000 corresponds to 100.0A

1055

Battery voltage

22000 corresponds to 220.0Vdc


5000 corresponds to 50.00Hz

1056

Output frequency

1057

Input frequency

5000 corresponds to 50.00Hz

1058

Bypass voltage

22000 corresponds to 220.0Vac

1059

Bypass current

10000 corresponds to 100.0A

1060

AC output active power

10000 corresponds to 100.00kW

1061

AC output apparent power

10000 corresponds to 100.00kVA

1062

AC output load percentage

10000 corresponds to 100.0%

1063

Bypass frequency

5000 corresponds to 50.00Hz

1064

Battery autonomy

1 corresponds to 1 Minute

UPS JBUS/MODBUS Adapter

User Manual

53

54

Chapter 4 Troubleshooting

Chapter 4 Troubleshooting
1. After plugging the adapter in the SNMP slot of the UPS or FLP, the yellow LED (equipment communication LED) of
the adapter does not illuminate.
Cause analysis and solution: the UPS or FLP is off or has no mains input. Please turn on the UPS or FLP; if the UPS
or FLP cannot be turned on, please connect the mains input to the UPS or FLP and try again.
2. After the adapter is installed, the yellow LED (equipment communication LED) of the adapter illuminates, and the
host monitoring software cannot monitor the UPS or FLP normally.
Cause analysis and solution: the UPS or FLP is on, but the communication between the adapter and the UPS or FLP
has not been established. Please pull out the adapter, check for the presence and proper insertion of the chip on the
PCB. If the check proves satisfactory, the adapter must be damaged, please contact the customer service center of
Emerson.
3. After the adapter is installed, the yellow LED (equipment communication LED) of the adapter flashes about once
per 5s, and the host monitoring software cannot monitor the UPS or FLP normally.
Cause analysis and solution: the yellow LED flashing once per 5s indicates the adapter cannot detect the UPS or
FLP or recognize the UPS or FLP type. Please check if the adapter matches the UPS or FLP type according to the
hardware description in section 1.3. The adapter can recognize the UPS or FLP type. After it recognizes the UPS or
FLP, the yellow LED will flash quickly, about once per 1s.
4. The yellow LED (equipment communication LED) flashes quickly, the green LED (host communication LED) is off.
Cause analysis and solution: the adapter is not properly connected to the host computer. Please properly connect the
adapter to the host computer following the instructions provided in section 2.3.3.
5. The yellow LED (equipment communication LED) flashes quickly, the green LED (host communication LED)
flashes too, but the host monitoring software cannot monitor the UPS or FLP normally.
Cause analysis and solution: the yellow LED flashing quickly indicates the communication between the adapter and
the UPS or FLP is normal; if the green LED flashes but the host monitoring software cannot detect the UPS or FLP
data, please check that: 1) the communication cable is properly connected between the adapter and the host
computer; 2) the adapters physical address and communication baud rate settings are the same as those set in the
host monitoring software; 3) the adapters physical address setting does not conflict with that of any other monitored
equipment (applicable only in RS485 cascade connection).

UPS JBUS/MODBUS Adapter

User Manual

Emerson Network Power, a business of Emerson


(NYSE:EMR),a global company that leads by applying a unique
combination of industry expertise, technology, and resources to
make the future of our customers' enterprises and networks
possible.

Emerson Network Power provides innovative solutions and


expertise in areas including AC and DC power and precision
cooling systems, embedded computing and power,
integrated racks and enclosures, power switching and
controls, infrastructure management and connectivity.
All solutions are supported globally by local Emerson
Network Power service technicians.

While every precaution has been taken to ensure the accuracy and completeness of this
literature, Emerson Network Power assumes no responsibility and disclaims all liability for
damages resulting from use of this information or for any errors or omissions.
All rights reserved throughout the world.
Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners

31011134-V1.7

www.EmersonNetworkPower.com

Вам также может понравиться