SHEET LIST
Sheet Name
TITLE SHEET
GN/SITE & LOCATION PLAN
GROUND FLOOR &1ST FLOOR
ARCHITECTURAL
2ND FLOOR & ROOF PLAN
ARCHITECTURAL
GENERAL ELEVATIONS
GENERAL ELEVATIONS
SECTIONS
BATHROOM INT./SCHEDULES/FURNITURE
LAYOUT
ELECTRICAL PLANS
ELECTRICAL PLANS
PLUMBING PLANS
PLUMBING PLANS
PLUMBING PLANS
AC INSTALATION PLAN
Sheet
Number
A1
A2
A3
PERSPECTIVE VIEW
A4
A5
A6
A7
A10
PROJECT DESCRIPTION
Project consisting of 6 units of same size.
Each unit has two separate residential
spaces on each level of aprox 490 sf interior
gross area and 130sf of veranda.
Each one with roof top acces.
E-1
E-2
P-1
P-2
P-3
SM-1
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
TITLE SHEET
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
A1
Scale
SYMBOLS
SIM
SECTION SYMBOL
A101
Ref
Ref
1 Ref
A101
1 Ref
NORTH SYMBOL
1
A101
SIM
GRID HEAD
ELEVATION SYMBOL
Name
Elevation
1t
WINDOW TAG
WALL TAG
1i
DOOR TAG
101
70' - 0"
SPOT ELEVATION
1 / A101
20 R @ 7 1/2"
39' - 0 1/4"
TITLE
#3952
#3954
75' - 0"
DN
View Name
1/8" = 1'-0"
25' - 0"
75' - 0"
VIEW REFERENCE
PROJECT DESCRIPTION
Projec
BOUNDRY
25' - 0"
BOUNDRY
REF.
8' - 0 1/2"
#3953
5' - 0"
8' - 0 1/2"
DN
5' - 11 3/4"
CANAL
RESIDENTIAL PROJECT
SITE PLAN
1" = 10'-0"
VICKY NELDER
ARCHITECT
BOB HAMILTON
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
A2
Scale As indicated
2
A7
14' - 8 1/2"
02
11
10
1a
LIVING
7
UP
11' - 3 7/8"
6
1
10
A7
1a
A7
12
12' - 10 3/8"
11' - 5"
W3
10
11
12
1a
13
0' - 8"
15 R @ 0' - 8"
UP
1
11
1a
12
1a
12' - 1"
11' - 5"
13' - 3"
11' - 5"
12' - 1"
8' - 0"
13
14' - 0 3/8"
W3
2a
18' - 2 1/2"
1a
13' - 11 3/4"
14
CISTERN
13 R @ 0' - 7 3/8"
15
11' - 5"
0' - 0"
15' - 2 3/8"
11' - 0 1/4"
25' - 0"
03
13 R @ 0' - 7 3/8"
6' - 1"
3' - 0"
0' - 8"
0' - 8"
24' - 2"
25' - 1"
4 7' - 8 5/8"
2a
1a
W2
KITCHEN/
ISLAND
BATHROOM
1a
07
1a
2a
A10
STORAGE
1' - 0"
15' - 2 3/8"
06
--1a
6' - 11"
---
CLOSET
3' - 0"
W1
1a
REF.
3a
9' - 0 1/2"
1a
1a
7' - 11 1/2"
4' - 9 1/2"
1a
PARKING
12' - 1"
11' - 5"
1
A10
11' - 5"
12' - 1"
8' - 10"
1a
2' - 0"
3' - 0"
1a
1a
7' - 0"
SEPTIC TANK
7' - 3 1/2"
A7
1a
0' - 8"
2' - 10 1/2"
Proyection
3' - 0"
4' - 0"
0' - 8"
1' - 11"
11' - 4 1/2"
12' - 1"
1' - 3"
12' - 11"
12' - 1"
4' - 0 1/4"
12' - 1"
3' - 2"
12' - 1"
25' - 0"
5' - 5 1/2"
25' - 1"
Proyection
1a
01
W2
4' - 0"
3' - 4 1/2"
DN
10' - 3 5/8"
13
1' - 10"
7' - 11"
Proyection
24' - 11 5/8"
4' - 0"
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
A3
Scale As indicated
25' - 0"
25' - 0"
12' - 1"
12' - 1"
12' - 1"
12' - 1"
8' - 2"
9' - 0" 2
A7
3' - 0"
W3
2' - 8 1/2"
9' - 0 5/8"
W3
2' - 9 1/2"
SHOWER
7' - 8 5/8"
DN
REF.
04
4' - 0"
W2
BATHROOM
10
---
DRAIN
PIPE
15' - 8 1/2"
W1
DRAIN
PIPE
15' - 2 3/8"
8
A10
19' - 7 1/8"
12' - 2"
8' - 0 3/8"
2' - 0"
12' - 1"
4' - 9 1/2"
UP
BEDROOM
0.5%
0.5%
0.5%
0.5%
18' - 0"
3' - 0"
33' - 9 1/4"
4' - 5"
25' - 0"
05
8' - 3 5/8"
DN
18' - 2 3/8"
13
W3
12' - 1"
18' - 2 1/2"
14
12
11
12' - 0"
10
OPEN
1
A7
15 R @ 0' - 8"
DN
3
13' - 7 5/8"
W4
W4
2' - 6" 1' - 2" 2' - 6" 1' - 2" 2' - 6"
3' - 3 1/2"
W4
1' - 6"
2' - 9 1/4"
3' - 3 1/2"
25' - 7"
24' - 11 5/8"
0.5%
0.5%
DRAIN
PIPE
DRAIN
PIPE
TREATED PINE
WOOD LATTICE
3' - 10"
ROOF PLAN
1/4" = 1'-0"
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
Author
Designer
A4
Scale As indicated
25' - 0"
25' - 0"
12' - 1"
Galv. Railing
12' - 1"
Galv. Railing
12' - 1"
12' - 1"
2
A7
28' - 6"
28' - 6"
28' - 6"
PALAPA
28' - 0"
A7
---
28' - 6"
PALAPA
28' - 0"
15 R @ 0' - 8"
W4
W4
10' - 0"
W4
10' - 0"
15 R @ 0' - 8"
10' - 0"
10' - 0"
W2
5
4
3
2
1
W2
3' - 5"
3' - 4"
Galv. Railing
28' - 0"
W3
7' - 1 1/2"
Galv. Railing
01
1ST FLOOR
8' - 0"
13
1' - 3"
1ST FLOOR
8' - 0"
1' - 6"
W3
Galv. Railing
10' - 0"
28' - 6"
28' - 0"
10' - 0"
3' - 9 1/2"
10' - 0"
28' - 6"
W2
6' - 8"
2ND FLOOR
18' - 0"
1' - 6"
2ND FLOOR
18' - 0"
12
11
10
9
07
8' - 0"
13 R @ 0' - 7 3/8"
6' - 10"
6' - 8"
8' - 0"
OPEN
8' - 0"
6' - 8"
8' - 0"
13 R @ 0' - 7 3/8"
2
1
GROUND LEVEL
0' - 0"
GROUND LEVEL
0' - 0"
Elevation 1 - a
1/4" = 1'-0"
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
Elevation 2 - a
1/4" = 1'-0"
GENERAL ELEVATIONS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
A5
Scale 1/4" = 1'-0"
2
A7
24' - 2 1/8"
25' - 0"
12' - 1"
PALAPA
28' - 0"
---
A7
28' - 6"
28' - 6"
PALAPA
28' - 0"
W1
W3
W3
10' - 0"
28' - 6"
12' - 1"
10' - 0"
12' - 1"
12' - 1"
W3
17' - 2"
05
9 R @ 0' - 8"
2ND FLOOR
18' - 0"
2ND FLOOR
18' - 0"
W3
3' - 5"
3' - 4"
Galv. Railing
GROUND LEVEL
0' - 0"
VICKY NELDER
ARCHITECT
BOB HAMILTON
8' - 0"
OPEN
GROUND LEVEL
0' - 0"
Elevation 3 - a
1/4" = 1'-0"
RESIDENTIAL PROJECT
6' - 10"
8' - 0"
6' - 8"
8' - 0"
1ST FLOOR
8' - 0"
6' - 10"
1ST FLOOR
8' - 0"
Elevation 4 - a
1/4" = 1'-0"
GENERAL ELEVATIONS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HR
HR
A6
Scale 1/4" = 1'-0"
28' - 0"
10' - 0"
28' - 6"
W1
28' - 0"
10' - 0"
1' - 6"
21' - 8"
16' - 7 1/2"
25' - 0"
25' - 0"
12' - 1"
12' - 1"
12' - 1"
2
28' - 6"
28' - 6"
28' - 6"
A7
A7
---
PALAPA
28' - 0"
1' - 2"
PALAPA
28' - 0"
12' - 1"
2a
1a
1a
1a
W4
10' - 0"
W3
10' - 0"
W3
1a
15 R @ 0' - 8"
10' - 0"
1a
2a
W3
05
15 R @ 0' - 8"
04
OPEN
Galv. Railing
2ND FLOOR
18' - 0"
1a
3' - 0 1/2"
1' - 6"
Galv. Railing
02
2a
2a
W3
01
Galv. Railing
3a
1a
OPEN
GROUND LEVEL
0' - 0"
Section 7
1/4" = 1'-0"
VICKY NELDER
ARCHITECT
BOB HAMILTON
07
13 R @ 0' - 7 3/8"
GROUND LEVEL
0' - 0"
RESIDENTIAL PROJECT
8' - 0"
CISTERN
8' - 0"
1a
8' - 0"
1ST FLOOR
8' - 0"
6' - 10"
1ST FLOOR
8' - 0"
1a
10' - 0"
28' - 0"
W3
1a
28' - 0"
W3
10' - 0"
28' - 0"
2a
28' - 0"
21' - 2"
2ND FLOOR
18' - 0"
10' - 0"
2a
Section 8
1/4" = 1'-0"
SECTIONS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
A7
Scale 1/4" = 1'-0"
10' - 0"
4' - 1 1/4"
2' - 0"
3' - 6"
W-1
5' - 2 5/8"
W-2
W-3
W-4
D1
WINDOWS LEGEND
1/4" = 1'-0"
2' - 6"
6' - 4"
6' - 11"
7' - 3"
2' - 0"
3' - 0"
3' - 0"
4' - 0"
7' - 11 1/2"
4' - 7"
A10
7' - 3"
7' - 0"
5' - 0"
4' - 0"
4' - 0"
3' - 0"
4' - 1 1/2"
3
5
4' - 6"
2' - 6"
06
W1
3' - 6"
CLOSET
3' - 5"
3' - 2"
3' - 1 1/4"
3' - 0"
D2
D3
D4
D5
DOOR LEGEND
1/4" = 1'-0"
02
*
- FRAMES ON WINDOWS TO BE ALUMINUM TYPE WITH DARK OAK
WOOD FINISH.
- HURRICANE IMPACT SYSTEM WINDOWS AND DOORS
- BRONCE TINTED GLASS ON ALL DOORS AND WINDOW TYPES.
- SINGLE DOORS AND BIFOLD TO HAVE AN EXTRA 1 SPACE AT
OPENINGS FOR WOOD FRAMING INSTALATION.
- APPLY GE II WINDOW AND DOOR SILICONE CAULK OR SIMILAR AND
WEATHER-TIGHT SEALS TO
DOOR AND WINDOS.
Window Schedule
Type
W1
W1
W2
W2
W2
W3
W3
W3
W3
W3
W3
W4
W4
W4
2'X1' GRAY
TILE
2'X1' GRAY
TILE
2'X1' GRAY
TILE
W1
W1
2'X1' GRAY
TILE
CLOSET
02
06
Width
2' - 0"
2' - 0"
4' - 0"
4' - 0"
4' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
2' - 6"
2' - 6"
2' - 6"
Height
3' - 0"
3' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
5' - 0"
5' - 0"
5' - 0"
Head Height
Sill Height
7' - 0"
7' - 0"
7' - 0"
6' - 7"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
8' - 0"
8' - 0"
8' - 0"
4' - 0"
4' - 0"
3' - 0"
2' - 7"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
02
06
T e
p y
iC
n
to
c
7
0
t2
h
rig
DOOR SCHEDULE
Mark
Bathroom A
1/4" = 1'-0"
Bathroom B
1/4" = 1'-0"
Bathroom C
1/4" = 1'-0"
Bathroom D
1/4" = 1'-0"
Type
Count
Level
01
02
03
04
05
06
D1
D2
D3
D2
D2
D4
1
1
1
1
1
1
1ST FLOOR
1ST FLOOR
1ST FLOOR
2ND FLOOR
2ND FLOOR
1ST FLOOR
07
D5
GROUND LEVEL
Desc.
Height
Width
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
6' - 8"
10' - 0"
2' - 6"
3' - 0"
2' - 6"
2' - 6"
4' - 0"
6' - 1"
3' - 0"
Material
SHOWER
8
7
A10
5' - 2 1/4"
W1
04
2'X1' GRAY
TILE
2'X1' GRAY
TILE
W1
3' - 2 1/4"
W1
8' - 0 3/8"
2' - 6 1/8"
2'X1' GRAY
TILE
2'X1' GRAY
TILE
04
10
W1
04
04
3' - 6"
BATHROOM
RESIDENTIAL PROJECT
1-a
1/4" = 1'-0"
1-b
1/4" = 1'-0"
VICKY NELDER
ARCHITECT
BOB HAMILTON
1-c
1/4" = 1'-0"
10
1-d
1/4" = 1'-0"
BATHROOM INT./SCHEDULES/FURNITURE
LAYOUT
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HR
HR
A10
Scale As indicated
REF.
UP
UP
DN
ELECTRICAL LEGENG
GFI
ELECTRICAL NOTES
1.All electrical equipment and wiring is to be installed per the applicable codes in the
area.
2.Electrical power source location specified in the site plan.
3.Materials and wiring to be used shall be brand new and approved type for the
particular location and purpose of usage.
4.Mounting height of wiring devices specified in electrical legend.
5.Use 220 Volts outlets for air conditioner power conection and installation should be
adjacent to units at same level of a.c. location.
6.Panel boards to be installed @ 5 A.F.F.
7.Lighting accessories to be selected by owner.
8.Switching devices should be installed @ 4 A.F.F unless specified.
9.Outlet devices should be installed @ 16 A.F.F unless specified.
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
PENDANT LIGHT
CONTROL PANEL
RECESSED LIGHT
QUADRUPLEX
DOOR BELL
DUPLEX GFI
LV
PHONE/INTERNET DATA
CHANDALIER
TV CONECTION
DIMMER
DUPLEX
FLUORESCENT LIGHT
D
220 V
THREE WAY
A.C POWER CONNECTION
QUADRUPLEX @ 48" A.F.F.
SINGLE SWITCH
ELECTRICAL PLANS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
PHOTOCELL LIGHT
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
E-1
Scale As indicated
UP
ELECTRICAL NOTES
1.All electrical equipment and wiring is to be installed per the applicable codes in the
area.
2.Electrical power source location specified in the site plan.
3.Materials and wiring to be used shall be brand new and approved type for the
particular location and purpose of usage.
4.Mounting height of wiring devices specified in electrical legend.
5.Use 220 Volts outlets for air conditioner power conection and installation should be
adjacent to units at same level of a.c. location.
6.Panel boards to be installed @ 5 A.F.F.
7.Lighting accessories to be selected by owner.
8.Switching devices should be installed @ 4 A.F.F unless specified.
9.Outlet devices should be installed @ 16 A.F.F unless specified.
DN
ELECTRICAL LEGENG
DN
GFI
PENDANT LIGHT
CONTROL PANEL
RECESSED LIGHT
QUADRUPLEX
DOOR BELL
DUPLEX GFI
LV
PHONE/INTERNET DATA
CHANDALIER
TV CONECTION
DIMMER
DUPLEX
FLUORESCENT LIGHT
WALL LIGHT (LED)
220 V
THREE WAY
PHOTOCELL LIGHT
A.C POWER CONNECTION
QUADRUPLEX @ 48" A.F.F.
SINGLE SWITCH
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
ELECTRICAL PLANS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
Author
Designer
E-2
Scale As indicated
1%
1%
MEASURER
Proyection
1%
1%
1%
1%
REF.
1%
SEPTIC TANK
1%
1%
"
d2
1%
d4"
1%
1%
"
d4
"
d2
"
d4
d2"
1%
1%
1%
4" 1ST
FLOOR
CISTERN
UP
UP
DN
PLUMBING NOTES
WASTE
1.Pitch all sanitary and waste pipes shown on this drawing as follows: Piping 3 or smaller pitch at 2% (1/4 per ft) minimum. Piping 4 or larger pitch at
1% (1/8 per ft) minimum
2.All new waste and vent pipes to be pvc.
3.All water lines to be pvc.
4.All sanitary sewer vents to be pcv.
5.All hot water pipe to be cpvc.
6.Main waste pipe to be connected to main drain leading to septic tank.
7.Bathroom fixtures and accessories to be selected by owner. Owner should notify general contractor or architect of any possible changes concerning
design and dimensions of accessories of spaces.
8.Piping for vent to be 2 min.
9.Piping for waste to be 4 with 1% pitch.
10.Piping for waste to be 2 min. unless otherwise noted.
11. On site verification is rquired, as this plumbing plan is representative and
may not represent the exact locations of piping. 12. In all cases hide plumbing into walls or slabs and avoid exposure to these in main elevations.
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
TEE 4"
TEE 2"
METER
TEE
45 ELBOW(4")
45 ELBOW(2")
WATER
HEATER
WH
45 ELBOW
WTR HEATER
TURN OFF
GATE VALVE
ADAPTER
90 ELBOW (2")
WATER GOES UP
90 ELBOW
VENT
WATER GOES DN
FLOOR DRAIN
HEATER
GLOBE VALVE
RETURN
SKIMMER
POOL DRAIN
PLUMBING PLANS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
WATER SUPPLY
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HRM
HRM
P-1
Scale As indicated
1%
1%
1%
d2
"
1%
d4"
d2
"
d4"
1%
1%
d4"
UP
DN
PLUMBING LEGEND
WASTE
WATER SUPPLY
TEE 4"
TEE 2"
METER
TEE
45 ELBOW(4")
45 ELBOW(2")
WATER
HEATER
WH
45 ELBOW
WTR HEATER
TURN OFF
GATE VALVE
ADAPTER
90 ELBOW (2")
WATER GOES UP
90 ELBOW
VENT
WATER GOES DN
FLOOR DRAIN
DN
HEATER
GLOBE VALVE
RETURN
SKIMMER
POOL DRAIN
PLUMBING NOTES
1.Pitch all sanitary and waste pipes shown on this drawing as follows: Piping 3 or smaller pitch at 2% (1/4 per ft) minimum. Piping 4 or larger pitch at
1% (1/8 per ft) minimum
2.All new waste and vent pipes to be pvc.
3.All water lines to be pvc.
4.All sanitary sewer vents to be pcv.
5.All hot water pipe to be cpvc.
6.Main waste pipe to be connected to main drain leading to septic tank.
7.Bathroom fixtures and accessories to be selected by owner. Owner should notify general contractor or architect of any possible changes concerning
design and dimensions of accessories of spaces.
8.Piping for vent to be 2 min.
9.Piping for waste to be 4 with 1% pitch.
10.Piping for waste to be 2 min. unless otherwise noted.
11. On site verification is rquired, as this plumbing plan is representative and
may not represent the exact locations of piping. 12. In all cases hide plumbing into walls or slabs and avoid exposure to these in main elevations.
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
PLUMBING PLANS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
Author
Designer
P-2
Scale As indicated
RESIDENTIAL PROJECT
VICKY NELDER
ARCHITECT
BOB HAMILTON
PLUMBING PLANS
IN COLABORATION WITH:
VICKY
NELDER
ASSOCIATES
NOTE: NO REPRODUCTION OF THESE PLANS MAY BE MADE WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT, AND WHEN MADE
MUST BEAR THE ARCHITECT'S NAME. SHOULD CONDITIONS ARISE WHERE BY CERTAIN SPECIFICATIONS CAN NOT BE IMPLEMENTED ,THE
CONTRACTOR MUST FIRST CONSULT WITH THE ARCHITECT FOR ADJUSTMENTS BEFORE CONSTRUCTION CAN PROCEED. THESE
DRAWINGS ARE ONLY TO BE USED FOR THE CONSTRUCTION OF THE NOTED PROJECT THE NOTED SITE SHALL NOT BE USED ON ANY
OTHER SITE WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT. ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR ANY
CHANGING OF DATA, DIMENSIONS, OR SPECIFICATION MADE BY THE CONTRACTOR OR OUTSIDER WITHOUT AUTHORIZATION AFTER
PLANS HAVE BEEN RELEASED!
Project number
0512016
Date
1-APRIL-16
Drawn by
Desinged by
HR
HR
P-3
Scale As indicated