Вы находитесь на странице: 1из 2

remote support.

Checking the storage critical Events.


Controlling & Monitoring Network Interface.
Checking the status of aggregate and volume usage using DFM.
Checking the ticketing tool and mails.
Configuring and troubleshooting SnapMirror Environment.
Performing Daily health check to monitor the usage of LUN, Aggregate and volume
utilization.
Configuring H drive for the users in the environment.
Restoring the data using snap restore and CIFS shares.
Dealing with permissions (Adding/removing the security groups to the shares) for
share folders in CIFS.
Configuring and troubleshooting SnapVault Environment.
Performed DR test for the environment.
Snapshot, lunclone, flexclone management.
Setting up and troubleshooting V-Filer Environment.
Lun management (LUN creation, LUN snapshots, Manual and automatic igroup managem
ent, LUN restore) using Snapdrive.
Setting up and troubleshooting NFS, CIFS, and SAN (FC and ISCSI) Environment.
Configuring windows ISCSI Boot LUN for the environment.
Ontap OS upgrade from 7.3.3 to 8.0 7 mode.
Storage remediation like HBA driver and firmware upgrade.
Adding disk shelf to the existing storage for standalone and High availability c
ontrollers. (involved in ontap upgrade documents team )
Assigning LUN s (FC and ISCSI) to distributed server in various environments.
Resolving the hardware issues in co-ordination with Netapp.
Managing the reports using operations manager.
Working with qtree s for efficient storage utilization for the users.
Performing Deduplication for the volumes.
Volume resize, aggregate disk add and lun resize
Alias, zoning configuration for the servers connected in FC environment in broca
de switches.
Able to create/Expand aggregate, volume, Qtree for NAS environments, LUN s, Igroup
s for SAN environments and also reclamation the LUN s and SAN ports if any (De-com
missioning projects).
FAS01> vol status -f (or) aggr status -f
FAS01> environment chassis list-sensors
The command "environment status chassis all" displays the power supply, fans , t
emperature sensor, nvram status etc.
filer> environment status chassis all
Temperature ok
PSU 1 ok
PSU 2 ok
Voltage ok
SYS FAN ok
NVRAM6-temperature-3 ok
NVRAM6-battery-3 ok.
FAS01> vol status
FAS01> aggr status
FAS01> df -Ah
FAS01> df -h
FAS01> lun show offline
FAS01> sysconfig -a
FAS01> rdfile /etc/messages
FAS01>aggr show_space aggr0

FAS01> aggr status -s