0 оценок0% нашли этот документ полезным (0 голосов)
400 просмотров2 страницы
This document provides the technical specifications for a power transformer. It includes details such as:
- The transformer is a 6300/110 kV unit to be installed at the Malchin substation.
- It is an oil-immersed transformer with an on-load tap changer that can operate from -45°C to 40°C.
- Electrical characteristics include a 6300/6300/6300 kVA rating at 50 Hz with high voltage of 115 kV and voltages of 38.5 kV and 10.5 kV.
- Documentation will be provided in English including name plates and operation manuals.
This document provides the technical specifications for a power transformer. It includes details such as:
- The transformer is a 6300/110 kV unit to be installed at the Malchin substation.
- It is an oil-immersed transformer with an on-load tap changer that can operate from -45°C to 40°C.
- Electrical characteristics include a 6300/6300/6300 kVA rating at 50 Hz with high voltage of 115 kV and voltages of 38.5 kV and 10.5 kV.
- Documentation will be provided in English including name plates and operation manuals.
Авторское право:
Attribution Non-Commercial (BY-NC)
Доступные форматы
Скачайте в формате PDF, TXT или читайте онлайн в Scribd
This document provides the technical specifications for a power transformer. It includes details such as:
- The transformer is a 6300/110 kV unit to be installed at the Malchin substation.
- It is an oil-immersed transformer with an on-load tap changer that can operate from -45°C to 40°C.
- Electrical characteristics include a 6300/6300/6300 kVA rating at 50 Hz with high voltage of 115 kV and voltages of 38.5 kV and 10.5 kV.
- Documentation will be provided in English including name plates and operation manuals.
Авторское право:
Attribution Non-Commercial (BY-NC)
Доступные форматы
Скачайте в формате PDF, TXT или читайте онлайн в Scribd
Type of electrical equipment SFSZ9-6300/110 Manufacturer Quantity 1set Location of installation Malchin-110/35/6kV Substation Description Unit Data 1 General data Ambient temperature ºC from-45 up to 40 Altitude m 1500 Relative humidity, max % 80 Standard IEC 60076 Installation Outdoor Oil-immersed power transfor- Kind of the transformer mer with on-load tap changer 2 Electrical data Rated power kVA 6300/6300/6300 Rated frequency Hz 50 HV 115 Rated voltage kV MV 38.5 LV 10.5 HV 9 x 1.78 Voltage regulation % MV 2 x 2.5 Connection group Yo/Yo/D-011 Neutral HV Cooling system ONAF 3 Other design requirements Built-in current transformer % No Supply voltage OLTC control circuits V AC220 Supply voltage OLTC motors V AC220 4 Documentation related requirements Name plate, operation manual and other related documents all should be in English language
OLTC On-load tap changer
ONAN Oil natural, air natural ONAF Oil natural, air forced
MCS International Co.,Ltd
Ulaanbaatar, Mongolia Technical specification Name of electrical equipment Power Transformer Type of electrical equipment SFZ9-630/35 Manufacturer Quantity 1set Location of installation Khyargas-35/10kV Substation Description Unit Data 1 General data Ambient temperature ºC from-45 up to 40 Altitude m 1500 Relative humidity, max % 80 Standard IEC 60076 Installation Outdoor Oil-immersed power transfor- Kind of the transformer mer with on-load tap changer 2 Electrical data Rated power kVA 630/630 Rated frequency Hz 50 HV 38.5 Rated voltage kV LV 10.5 HV 2 x 2.5 Voltage regulation % MV Connection group Yo/D-011 Neutral HV Cooling system ONAN 3 Other design requirements Built-in current transformer % No Supply voltage OLTC control circuits V AC220 Supply voltage OLTC motors V AC220 4 Documentation related requirements Name plate, operation manual and other related documents all should be in English language
OLTC On-load tap changer
ONAN Oil natural, air natural ONAF Oil natural, air forced