Вы находитесь на странице: 1из 1

NOTE:

DISTRIBUTION BARS Ls IS THE GREATER OF 2 CONSECUTIVE SPANS ANCHORAGE AND SPLICE LENGTHS OF
REFER NOTES ON PLAN (E.G. Ls1 & Ls2)
DISTRIBUTION BARS
REFER NOTES ON PLAN
TENSION BARS IN BEAMS AND SLABS
0.2 Ls1 0.3 Ls 150 150 0.3 Ls 0.3 Ls
LESS THAN 300 mm. OF CONCRETE MORE THAN 300 mm. OF CONCRETE
(600 MIN) 500 0.2 Ls 0.2 Ls 500 500 0.2 Ls
BELOW HORIZONTAL BAR BELOW HORIZONTAL BAR
500 LAP (600 MIN) (600 MIN) LAP LAP (600 MIN) BAR SIZE
LAP CONCRETE GRADE F'c CONCRETE GRADE F'c

200
32 MPa 40 MPa 32 MPa 40 MPa
N10 300 300 350 350
200 200
D N12 400 350 500 400
STOP ALTERNATE
STOP ALTERNATE BARS N16 650 550 800 700
BARS N20 900 800 1150 1000
REINF. AS NOTED 600 MAX N24 1100 1000 1350 1200
ON PLANS TYPICAL STOP ALTERNATE BARS
12 BAR DIA OR D (TYPICAL). N28 1250 1100 1600 1400
WHICHEVER IS THE 0.1 Ls1 0.1 Ls2 0.1 Ls2 N32 1600 1400 2000 1750
GREATER
N36 2000 1700 2400 2150
Ls1 BAND WIDTH REFER PLANS Ls2

GENERAL 50 BAR DIA 45 BAR DIA 65 BAR DIA 60 BAR DIA

NOTES :
1. THESE LENGTHS APPLY FOR ALL BARS IN BEAMS AND SLABS.
2. THE MINIMUM COVER TO THE BAR UNDER CONSIDERATION IS TO BE :
TYPICAL SECTION THROUGH R.C. SLAB AND BAND BEAM FOR SLAB AND BAND BEAM 20mm OR THE BAR DIAMETER, WHICH EVER IS GREATER.
SCALE 1:20 FOR BEAMS 40mm OR THE BAR DIAMETER, WHICHEVER IS GREATER.
3. THE MINIMUM CLEAR SPACING BETWEEN BARS MUST BE GREATER THAN TWICE THE COVER TO
THE BAR.
4. FOR SLABS WITH BARS AT LESS THAN 150 mm CENTRES TO BE ANCHORED OR SPLICED.
ANCHORAGE AND SPLICE LENGTHS NOTED ABOVE MUST BE MULTIPLIED BY 1.4.
5. UNLESS SHOWN ON THE DRAWINGS, THE SPLICE LOCATIONS MUST BE APPROVED BY
6. IF BARS HAVE STANDARD COGS AT THE ENDS, ANCHORAGE LENGTHS NOTED ABOVE CAN BE
HALVED.
7. N36, N40 AND N50 BARS IN TENSION ARE NOT TO BE LAP SPLICED UNLESS WITH THE WRITTEN
APPROVAL BY THE ENGINEER.
NOTE: 8. FOR PLAIN BARS USED AS LIGATURES OR TIES THE ANCHORAGE LENGTH SHALL BE 40 BAR
Ln IS THE GREATER OF 2 CONSECUTIVE SPANS DIAMETER BUT NOT LESS THAN 300mm. OTHER PLAIN BARS MUST BE ANCHORED WITH A
(E.G. Ln1 & Ln2) STANDARD HOOK OR COG.
N16-500 STOP ALTERNATE BARS
U.N.O. ON PLAN WHERE AN ODD NUMBER 9. THE ANCHORAGE LENGTH OF HAND DRAWN WIRE IS 50 BAR DIAMETER.
0.33 Ln1 0.33 Ln 0.33 Ln
OF BARS ARE SPECIFIED
600 THE EXTRA BAR SHALL 600 0.2 Ln 0.2 Ln 600
LAP BE LONG LAP LAP

0.1 Ln1 STAGGER ALTERNATE 0.1 Ln1 0.1 Ln2 ADDITIONAL BARS 50%
BARS (TYPICAL). MAX MAX OF BOTTOM REINF.
DENOTES BAR TERMINATION (STANDARD LAPS)

100 N12-300 UNLESS NOTED OTHERWISE ON PLAN 100 100 AS PER OPPOSITE
Ln1 Ln2 TO MATCH ADJACENT
TOP BARS

600 600
(TYPICAL) (TYPICAL)

TYPICAL SECTION ALONG CONTINUOUS SPAN R.C. BAND BEAM

BEAM UNDER
SCALE 1:20

1000 MAX

1000 MAX
(TYPICAL)

(TYPICAL)
600

600
TOP BARS - FOR EVERY
2 BARS STOPPED BY HOLE
0.33 Ln N16-500 0.33 Ln ADD ONE BAR EACH SIDE
U.N.O ON PLAN OF SAME GRADE & SIZE.
500 500 WHERE NO TOP BARS ARE
1000 MAX
LAP LAP SHOWN, ADD 1-N16 TOP EACH 1000 MAX
SIDE OF HOLE. (TYPICAL)

BOTTOM BARS - FOR EVERY


2 BARS STOPPED BY HOLE
ADD ONE BAR EACH SIDE
OF SAME GRADE & SIZE.
(TYPICAL)
0.1 Ln1 STAGGER ALTERNATE 0.1 Ln1
BARS (TYPICAL). MAX

REINFORCEMENT TO SLAB PENETRATIONS


100 N12-300 UNLESS NOTED OTHERWISE ON PLAN 100
NTS
Ln NOTES:
1. FOR HOLES LESS THAN 300 x 300mm, SLAB BARS TO BE REARRANGED
AROUND HOLE WITHOUT CUTTING.
2. FOR HOLES GREATER THAN 300 x 300mm BUT LESS THAN 1000 x 1000mm,
USE ABOVE DETAILS.
3. FOR HOLES GREATER THAN 1000 x 1000mm, REFER TO ENGINEERS PLANS.
TYPICAL SECTION ALONG SINGLE SPAN BAND BEAM 4. LOCATION OF HOLES TO BE TO THE APPROVAL OF THE ENGINEER.
SCALE 1:20
5. REFER ALSO TO THE STANDARD NOTES.

CRANK 1:6 MAX


PRIMARY BEAM

1200 TYP.
SETDOWN

SETDOWN

1.5 x T
1.5 x N

1-N12 LAP

750
=
WHERE REQ'D PRIMARY BEAM
D

=
N12-200 OR
N16-300
75 BARS CRANKED AT 1-N12 LAP
500 TYP.
SLOPE 1:6 MAX. WHERE REQ'D

SECONDARY BEAM SECONDARY BEAM

SETDOWN 0.2 x T
DWG FILE: X:\105492 - Darwin Chinatown\6BIM\6_2 MHT ST\105492-S0010.dwg - MH PLOT TIME: 20 Sep 2010, 12:09pm

SETDOWN 0.8 x T

TYPICAL SUSPENDED FLOOR DETAILS TYPICAL PRIMARY TO TYPICAL PRIMARY TO TYPICAL SIDE FACE REINFORCEMENT
SCALE 1:20
SECONDARY BEAM DETAIL SECONDARY BEAM DETAIL
NOTES: SCALE 1:20
SCALE 1:20 SCALE 1:20
1. DETAILS APPLY UNLESS OTHERWISE SHOWN.
2. REFER ALSO TO STANDARD NOTES.

DARWIN CHINATOWN
68 MITCHELL STREET, DARWIN NT
PC YJT TL

TYPICAL RC. BEAM AND SLAB DETAILS S0010


SHEET 1