Вы находитесь на странице: 1из 2

Page 1

Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 3-1-10 / 15:45 DMH – LWW - JRW
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
0631069 Circular Brick 62
Site ID: Address: Site Quality: Basin:
20 4654 Leavenworth St. Fair

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? Yes Manhole Depth (ft): 12.07 Surcharge Evidence? Yes
Needed Traffic Attendants: No Manhole Dia. (in): 62 Depth of Surcharge (ft): 7.5
H2S: 0 O2: 20.8 MH Cover Size (in): 22.75 Depth of Debris (in): 0
LEL: 0 CO: 0 MH Cover Type: Vented Usable MH Steps? No
Describe potential hazards: Measured Flow Depth (in): 3 Meter: 2150
Velocity (fps): 3 Cellular Signal Strength: Good
Traffic
Mounting Band Description: Antennae Install Considerations:

Band, anchors, drill Vented lid

Other Comments: Permanent Power Available?

Need cones and signs Yes


Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)


62 62

SURFACE DOWN

INFLOW OUTFLOW

Вам также может понравиться