Академический Документы
Профессиональный Документы
Культура Документы
FEATURES
LEHW0815-03 Page 1 of 4
G3616 GAS PETROLEUM ENGINE
Control System Caterpillar ADEM III control system Custom control system software is available
provides electronic governing integrated for non-standard ratings. Software is field
with air/fuel ratio control and individual programmable using flash memory.
cylinder ignition timing control
Ignition System ADEM III control system senses individual CSA certification
cylinder detonation and controls
individual cylinder timing
Instrumentation LCD display panel monitors engine Remote data monitoring and speed control
parameters and displays diagnostic codes Compatible with Cat Electronic Technician (ET)
and Data View
Customer Communication Module (CCM)
Display panel deletion is optional
Lube System Crankcase breathers (top mounted) Air or electric motor-driven prelube
Oil cooler Duplex oil filter
Oil filter LH or RH service
Oil pan drain valve Lube oil makeup system
Mounting System Engine mounting feet (six total) Mounting plates (set of six)
TECHNICAL DATA
G3616 Gas Petroleum Engine — 900-1000 rpm
DM5563-00 DM5563-00
Engine Power
@ 100% Load bhp (bkW) 4261 (3178) 4735 (3531)
@ 75% Load bhp (bkW) 3196 (2383) 3551 (2648)
Emissions*
NOx g/bhp-hr 0.70 0.70
CO g/bhp-hr 2.50 2.50
Total Hydrocarbons g/bhp-hr 6.51 6.01
Fuel Consumption
@ 100% Load Btu/bhp-hr (MJ/bkW-hr) 6688 (9.47) 6736 (9.53)
@ 75% Load Btu/bhp-hr (MJ/bkW-hr) 6981 (9.88) 7030 (9.95)
Heat Balance
Heat Rejection to Jacket Water
@ 100% Load Btu/min (bkW) 45,167 (794) 47,967 (843)
@ 75% Load Btu/min (bkW) 38,352 (674) 41,560 (731)
Exhaust System
Exhaust Gas Flow Rate
@ 100% Load cfm (m3/min) 28,743 (297) 32,336 (332)
@ 75% Load cfm (m3/min) 22,920 (230) 25,789 (257)
Intake System
Air Inlet Flow Rate
@ 100% Load cfm (m3/min) 10,682 (277) 11,953 (310)
@ 75% Load cfm (m3/min) 8261 (214) 9244 (240)
LEHW0815-03 Page 3 of 4
G3616 GAS PETROLEUM ENGINE
222.87 93.68
(5661.0) (2379.5)
126.30
(3208.1)
Genset 50 Hz 07/07
ENGINE DATA
FUEL CONSUMPTION (ISO 3046/1) (1) MJ/bkW-hr 9.31 9.69 10.4
FUEL CONSUMPTION (NOMINAL) (1) MJ/bkW-hr 9.53 9.92 10.65
AIR FLOW (@ 0°C, 101.3 kPaa) Nm3/min 313 243 163
AIR MASS FLOW kg/hr 24,265 18,866 12,647
COMPRESSOR OUTLET PRESSURE kPa (abs) 254 198 142
COMPRESSOR OUTLET TEMPERATURE °C 150 121 74
INLET MANIFOLD PRESSURE kPa (abs) 244 188 133
INLET MANIFOLD TEMPERATURE °C 64 62 61
LAMBDA 2.07 2.06 1.93
TIMING °BTDC 18.3 18.3 18.3
EXHAUST STACK TEMPERATURE °C 458 469 517
EXHAUST GAS FLOW (@ 0°C, 101.3 kPaa) Nm3/min 335 261 175
EXHAUST GAS MASS FLOW kg/hr 25,006 19,442 13,033
EMISSIONS
NOx (corr. to 5% O2) (3) mg/Nm3 350 312 280
CO (corr. to 5% O2) (3) mg/Nm3 1250 1113 1002
THC (corr. to 5% O2, molecular weight of 15.84) (3) mg/Nm3 3081 2810 2598
NMHC (corr. to 5% O2, molecular weight of 15.84) (3) mg/Nm3 463 422 390
EXHAUST OXYGEN % 12.5 11.8 10.8
NOTES
1) FUEL CONSUMPTION TOLERANCE. ISO 3046/1 IS 0, + 5% OF FULL LOAD DATA. NOMINAL IS ± 2.5 % OF FULL LOAD DATA.
2) ENGINE POWER AND WORK ENERGY INCLUDE 2 ENGINE DRIVEN WATER PUMPS.
3) EMISSION DATA SHOWN ARE DRY AND NOT TO EXCEED VALUES.
4) HEAT REJECTION TO JACKET AND EXHAUST TOLERANCE IS ± 10% OF FULL LOAD DATA. (heat rate based on treated water)
5) HEAT REJECTION TO ATMOSPHERE TOLERANCE IS ± 50% OF FULL LOAD DATA. (heat rate based on treated water)
6) HEAT REJECTION TO LUBE OIL TOLERANCE IS ± 20% OF FULL LOAD DATA. (heat rate based on treated water)
7) HEAT REJECTION TO AFTERCOOLER TOLERANCE IS ± 5% OF FULL LOAD DATA. (heat rate based on treated water)
8) TOTAL AFTERCOOLER HEAT = AFTERCOOLER HEAT x ACHRF (heat rate based on treated water)
DM5051 04
G3616 GAS ENGINE TECHNICAL DATA
50 1.00 1.00 0.96 0.93 0.89 0.86 0.83 0.80 0.77 0.74 0.71 0.69 0.66
45 1.00 1.00 0.99 0.96 0.93 0.91 0.88 0.85 0.81 0.78 0.75 0.73 0.70
AIR 40 1.00 1.00 1.00 0.98 0.95 0.92 0.89 0.86 0.83 0.81 0.78 0.76 0.73
TO 35 1.00 1.00 1.00 1.00 0.96 0.93 0.91 0.88 0.85 0.82 0.79 0.77 0.74
TURBO 30 1.00 1.00 1.00 1.00 0.98 0.95 0.92 0.89 0.86 0.83 0.81 0.78 0.76
25 1.00 1.00 1.00 1.00 1.00 0.97 0.94 0.91 0.88 0.85 0.82 0.79 0.77
(°C) 20 1.00 1.00 1.00 1.00 1.00 0.98 0.95 0.92 0.89 0.86 0.84 0.81 0.78
15 1.00 1.00 1.00 1.00 1.00 1.00 0.97 0.94 0.91 0.88 0.85 0.82 0.80
10 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.95 0.92 0.89 0.86 0.84 0.81
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
ALTITUDE (METERS ABOVE SEA LEVEL)
50 1.35 1.41 1.46 1.52 1.57 1.57 1.57 1.57 1.57 1.57 1.57 1.57 1.57
45 1.28 1.33 1.38 1.44 1.49 1.49 1.49 1.49 1.49 1.49 1.49 1.49 1.49
AIR 40 1.20 1.25 1.30 1.36 1.41 1.41 1.41 1.41 1.41 1.41 1.41 1.41 1.41
TO 35 1.12 1.17 1.23 1.28 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33
TURBO 30 1.05 1.10 1.15 1.20 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
25 1.00 1.02 1.07 1.12 1.17 1.17 1.17 1.17 1.17 1.17 1.17 1.17 1.17
(°C) 20 1.00 1.00 1.00 1.04 1.09 1.09 1.09 1.09 1.09 1.09 1.09 1.09 1.09
15 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01
10 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
ALTITUDE (METERS ABOVE SEA LEVEL)
GENERATOR EFFICIENCY:
Generator power determined with an assumed generator effeciency of 97% [generator power=engine power x 0.97]. If the actual generator efficiency is less than 97%
[and greater than 95%], the generator power [ekW] listed in the technical data can still be achieved. The BSFC values must be increased by a factor.
The factor is a percentage = 97% - actual generator efficiency [%].