1. OPSYS’s Important Part Lists

Part No. Shape Dimension Material

30X50 Main Duct


PC&ABS
OP-0305MD 33 X 48.5 X 1.5T
(Halogen Free)
Length : 2,000mm

50 Main Duct
PC&ABS
OP-05MD 59 X 54.5 X 2.0T
(Halogen Free)
Length : 2,000mm
MAIN DUCT

100 Main Duct PC&ABS


OP-10MD 120 X 106(+7) X 3.0T (Halogen Free)
Length : 2,000mm ABS

160 Main Duct


PC&ABS
OP-16MD 181 X 106(+7) X 3.5T
(Halogen Free)
Length : 2,000mm

220 Main Duct


PC&ABS
OP-22MD 241 X 106(+7) X 3.5T
(Halogen Free)
Length : 2,000mm

300 Main Duct


PC&ABS
OP-30MD 321 X 106(+7) X 3.5T
(Halogen Free)
Length : 2,000mm

30X50 Main Duct Cover


PC&ABS
MAIN DUCT COVER

OP-0305MDC 36 X 8 X 1.5T
(Halogen Free)
Length : 2,000mm

50 Main Duct Cover


PC&ABS
OP-05MDC 66 X 8.6 X 2.0T
(Halogen Free)
Length : 2,000mm

100 Main Duct Cover PC&ABS


OP-10MDC 120 X 16.5 X 3.0T (Halogen Free)
Length : 2,000mm ABS

160 Main Duct Cover


PC&ABS
OP-16MDC 181 X 17 X 3.5T
(Halogen Free)
Length : 2,000mm

Optical Fiber Raceway Ducting System -2- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

220 Main Duct Cover


PC&ABS
COVER

OP-22MDC 241 X 17 X 3.5T


(Halogen Free)
Length : 2,000mm

300 Main Duct Cover


PC&ABS
OP-30MDC 321 X 17 X 3.5T
(Halogen Free)
Length : 2,000mm

100 H-Cross
PC&ABS
OP-10CA 260 X 106 X 3.0T
(Halogen Free)
Length : 260mm

160 H-Cross
PC&ABS
OP-16CA 300 X 106 X 3.5T
CROSS

(Halogen Free)
Length : 300mm

220 H-Cross
PC&ABS
OP-22CA 360 X 106(+5) X 3.5T
(Halogen Free)
Length : 360mm

300 H-Cross
PC&ABS
OP-30CA 440 X 106(+5) 3.5T
(Halogen Free)
Length : 440mm

100 H-Cross Cover


PC&ABS
OP-10CAC 265 X 34 X 3.0T
(Halogen Free)
Length : 265mm
CROSS COVER

160 H-Cross Cover


PC&ABS
OP-16CAC 307 X 27 X 3.0T
(Halogen Free)
Length : 307mm

220 H-Cross Cover


PC&ABS
OP-22CAC 367 X 34 X 3.0T
(Halogen Free)
Length : 367mm

300 H-Cross Cover


PC&ABS
OP-30CAC 446.5 X 27 X 3.0T
(Halogen Free)
Length : 446.5mm

Optical Fiber Raceway Ducting System -3- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

30X50 H-Tee
PC&ABS
OP-0305TA 75 X 52.5 X 1.5T
(Halogen Free)
Length : 55.5mm

100 H-Tee
PC&ABS
OP-10TA 260 X 106 X 3.0T
(Halogen Free)
Length : 183mm
TEE

160 H-Tee
PC&ABS
OP-16TA 300 X 106 X 3.5T
(Halogen Free)
Length : 233.5mm

220 H-Tee
PC&ABS
OP-22TA 360 X 106(+5) X 3.5T
(Halogen Free)
Length : 293.5mm

300 H-Tee
PC&ABS
OP-30TA 440 X 106(+5) X 3.5T
(Halogen Free)
Length : 373.5mm

30X50 H-Tee Cover


PC&ABS
OP-0305TAC 59 X 9.5 X 1.5T
(Halogen Free)
Length : 47.5mm

100 H-Tee Cover


PC&ABS
OP-10TAC 265 X 34 X 3.0T
(Halogen Free)
TEE COVER

Length : 192.5mm

160 H-Tee Cover


PC&ABS
OP-16TAC 307 X 27 X 3.0T
(Halogen Free)
Length : 244mm

220 H-Tee Cover


PC&ABS
OP-22TAC 367 X 34 X 3.0T
(Halogen Free)
Length : 304mm

300 H-Tee Cover


PC&ABS
OP-30TAC 446.5 X 27 X 3.0T
(Halogen Free)
Length : 383.75mm

Optical Fiber Raceway Ducting System -4- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

30X50 H-Elbow 90’


PC&ABS
OP-0305HA 55.5 X 52.5 X 1.5T
(Halogen Free)
Length : 55.5mm
HORIZONTAL ELBOW

100 H-Elbow 45’


PC&ABS
OP-10HA 126.6 X 106 X 3.0T
(Halogen Free)
Length : 126mm

160 H-Elbow 45’


PC&ABS
OP-16HA 197.6 X 106 X 3.5T
(Halogen Free)
Length : 193.8mm

220 H-Elbow 45’


PC&ABS
OP-22HA 257.7 X 106(+5) X 3.5T
(Halogen Free)
Length : 236.3mm

300 H-Elbow 45’


PC&ABS
OP-30HA 337.7 X 106(+5) X 3.5T
(Halogen Free)
Length : 373.5mm
HORIZONTAL ELBOW COVER

30X50 H-Elbow 90’ Cover


PC&ABS
OP-0305HAC 47.5 X 9.5 X 1.5T
(Halogen Free)
Length : 47.5mm

100 H-Elbow 45’ Cover


PC&ABS
OP-10HAC 140.6 X 34 X 3.0T
(Halogen Free)
Length : 135.5mm

160 H-Elbow 45’ Cover


PC&ABS
OP-16HAC 212.7 X 27 X 3.0T
(Halogen Free)
Length : 205.5mm

220 H-Elbow 45’ Cover


PC&ABS
OP-22HAC 272.7 X 34 X 3.0T
(Halogen Free)
Length : 247.8mm

300 H-Elbow 45’ Cover


PC&ABS
OP-30HAC 352.5 X 27 X 3.0T
(Halogen Free)
Length : 304mm

Optical Fiber Raceway Ducting System -5- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

50 V-Elbow 45’ Down


PC&ABS
OP-05DA 54 X 63.45 X 2.0T
(Halogen Free)
Length : 99mm

100 V-Elbow 45’ Down


PC&ABS
DOWN ELBOW

OP-10DA 106 X 119.25 X 3.0T


(Halogen Free)
Length : 155.5mm

160 V-Elbow 45’ Down


PC&ABS
OP-16DA 167 X 119.2 X 3.5T
(Halogen Free)
Length : 155.5mm

220 V-Elbow 45’ Down


PC&ABS
OP-22DA 227 X 119.2 X 3.5T
(Halogen Free)
Length : 155.5mm

300 V-Elbow 45’ Down


PC&ABS
OP-30DA 307 X 119.2 X 3.5T
(Halogen Free)
Length : 155.5mm

50 V-E 45’ Down Cover


PC&ABS
OP-05DAC 66 X 21.5 X 2.5T
(Halogen Free)
Length : 104.5mm
DOWN ELBOW COVER

100 V-E 45’ Down Cover


PC&ABS
OP-10DAC 120 X 54.5 X 3.0T
(Halogen Free)
Length : 175.5mm

160 V-E 45’ Down Cover


PC&ABS
OP-16DAC 181 X 48.5 X 3.0T
(Halogen Free)
Length : 177mm

220 V-E 45’ Down Cover


PC&ABS
OP-22DAC 241 X 55 X 3.0T
(Halogen Free)
Length : 177mm

300 V-E 45’ Down Cover


PC&ABS
OP-30DAC 321 X 47.5 X 3.0T
(Halogen Free)
Length : 177mm

Optical Fiber Raceway Ducting System -6- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

50 V-Elbow 45’ Up
PC&ABS
OP-05UA 54 X 63 X 2.0T
(Halogen Free)
Length : 99mm

100 V-Elbow 45’ Up


PC&ABS
OP-10UA 106 X 118 X 3.0T
(Halogen Free)
Length : 152.5mm
UP ELBOW

160 V-Elbow 45’ Up


PC&ABS
OP-16UA 167 X 118.5 X 3.5T
(Halogen Free)
Length : 152mm

220 V-Elbow 45’ Up


PC&ABS
OP-22UA 227 X 118.5 X 3.5T
(Halogen Free)
Length : 156mm

300 V-Elbow 45’ Up


PC&ABS
OP-30UA 307 X 119 X 3.5T
(Halogen Free)
Length : 156mm

50 V-E 45’ Up Cover


PC&ABS
OP-05UAC 66 X 22.5 X 2.5T
(Halogen Free)
Length : 65mm
UP ELBOW COVER

100 V-E 45’ Up Cover


PC&ABS
OP-10UAC 120 X 46 X 3.0T
(Halogen Free)
Length : 87.5mm

160 V-E 45’ Up Cover


PC&ABS
OP-16UAC 181 X 49.5 X 3.0T
(Halogen Free)
Length : 83.5mm

220 V-E 45’ Up Cover


PC&ABS
OP-22UAC 241 X 47 X 3.0T
(Halogen Free)
Length : 92.5mm

300 V-E 45’ Up Cover


PC&ABS
OP-30UAC 321 X 40 X 3.0T
(Halogen Free)
Length : 80.5mm

Optical Fiber Raceway Ducting System -7- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

100~50 Reducer
PC&ABS
OP-10RD 106 X 106 X 3.0T
(Halogen Free)
Length : 110mm
REDUCER

160~100 Reducer
PC&ABS
OP-16RD 167 X 106 X 3.5T
(Halogen Free)
Length : 125mm

220~160 Reducer
PC&ABS
OP-22RD 227 X 106 X 3.5T
(Halogen Free)
Length : 140mm

300~220 Reducer
PC&ABS
OP-30RD 307 X 106(+5) X 3.5T
(Halogen Free)
Length : 150mm

100~50 Reducer Cover


PC&ABS
OP-10RDC 120 X 75 X 3.0T
(Halogen Free)
REDUCER COVER

Length : 114.5mm

160~100 Reducer Cover


PC&ABS
OP-16RDC 181 X 27 X 3.0T
(Halogen Free)
Length : 131mm

220~160 Reducer Cover


PC&ABS
OP-22RDC 241 X 34 X 3.0T
(Halogen Free)
Length : 147mm

300~220 Reducer Cover


PC&ABS
OP-30RDC 321 X 27 X 3.0T
(Halogen Free)
Length : 156.5mm
TRUMPET

50 Outlet Trumpet
PC&ABS
OP-05TP 96 X 54 X 2.0T
(Halogen Free)
Length : 45.5mm

100 Outlet Trumpet


PC&ABS
OP-10TP 192 X 106 X 3.0T
(Halogen Free)
Length : 86mm

Optical Fiber Raceway Ducting System -8- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

160 Outlet Trumpet


PC&ABS
OP-16TP 260 X 200 X 3.5T
(Halogen Free)
Length : 80mm
TRUMPET

220 Outlet Trumpet


PC&ABS
OP-22TP 320 X 200 X 3.5T
(Halogen Free)
Length : 80mm

300 Outlet Trumpet


PC&ABS
OP-30TP 400 X 200 X 3.5T
(Halogen Free)
Length : 80mm

100 End Cap


PC&ABS
OP-10EC 114.5 X 127 X 3.0T
(Halogen Free)
Length : 13mm

160 End Cap


END CAP

PC&ABS
OP-16EC 175 X 127 X 3.0T
(Halogen Free)
Length : 13mm

220 End Cap


PC&ABS
OP-22EC 233 X 124 X 3.0T
(Halogen Free)
Length : 19mm

300 End Cap


PC&ABS
OP-30EC 314 X 127 X 3.0T
(Halogen Free)
Length : 13mm

100 H-Top
PC&ABS
TOP & COVER

OP-10HT 288 X 153 X 3.0T


(Halogen Free)
Length : 200mm

100 H-Top Cover


PC&ABS
OP-10HTC 248 X 84.5 X 3.0T
(Halogen Free)
Length : 203mm

100 V-Top
PC&ABS
OP-10VT 220 X 90 X 3.0T
(Halogen Free)
Length : 196mm

Optical Fiber Raceway Ducting System -9- OPSYS®


Application Guide 2010
Part No. Shape Dimension Material

100 V-Top Cover


PC&ABS
OP-10VTC 180 X 97.5 X 3.0T
(Halogen Free)
Length : 215mm

50 Joiner
PC&ABS
OP-05JO 58 X 56 X 2.0T
(Halogen Free)
Length : 34(+4)mm

100 Joiner
PC&ABS
OP-10JO 112 X 109 X 3.0T
(Halogen Free)
Length : 45(+4)mm
JOINER

160 Joiner
PC&ABS
OP-16JO 196 X 119.5 X 3.0T
(Halogen Free)
Length : 55(+4)mm

220 Joiner
PC&ABS
OP-22JO 256 X 119.5 X 3.0T
(Halogen Free)
Length : 55(+4)mm

300 Joiner
PC&ABS
OP-30JO 336 X 119.5 X 3.0T
(Halogen Free)
Length : 55(+4)mm
Accessories

30X50 Cable Protector


PC&ABS
OP-0305CP 23.5 X 23 X 1.2T
(Halogen Free)
Length : 10mm

All Duct Cover Clip


PC&ABS
OP-D’CLIP 40 X 38 X 2~2.5T
(Halogen Free)
Length : 17.5mm

Insulator PC&ABS
OP-APP855
Additional

Ø 22 X 51 X 2.5T (Halogen Free)


OP-APP857
Ø 31 X 8 X 2.5T PVC

Tees Bolt & Nut PC&ABS


OP-T’BOLT 27.5 X 21 X 3.0T RUBBER
20 X 8.5 X 2.5T(M6X24) SCM440

Optical Fiber Raceway Ducting System - 10 OPSYS®


-
Application Guide 2010
Part No. Shape Dimension Material

100 Mounting Bracket


160 Mounting Bracket
OP-16SMTB SPCC
228 X 28 X 3.0T
Length : 56mm

220 Mounting Bracket


OP-22SMTB 290 X 28 X 3.0T SPCC
Length : 56mm

300 Mounting Bracket


OP-30SMTB 333 X 28 X 3.0T SPCC
Length : 56mm
SUPPORT BRACKET KIT

Side Drop Mounting Bracket


OP-10SDMB 124 X 72 X 3.0T SPCC
Length : 295mm

Pan Head Screw(L)


OP- M4 M4 X 10(160~300 Joiners)
SCM440
OP- M3 Pan Head Screw(S)
M3 X 6(50~100 Joiners)

Structure-
Mounting Bracket
OP-APP854 SPCC
112.5 X 63 X 6.0T
Length : 50mm

Structure(S) & (L)


OP-APP856-1 50 X 50 X 6.0T SPCC
L:3000 / S:1500mm

Structure Joiners
40 X 40 X 5.0T SPCC
OP-APP856-2
Hex Screw(M10X25) SCM440
Length : 160mm

Long Nut(5/8”)
Ø 21 X 55mm
OP-SP1’KITS SCM440
Anchor Set(5/8”)
Ø 21 X 122mm

Threaded Rod(5/8”)
5/8” X 600mm
OP-SP2’KITS SCM440
Cap Nut & Washer
5/8” X 25mm

Optical Fiber Raceway Ducting System - 11 OPSYS®


-
Application Guide 2010
2. OPSYS’s Ducting System Assembly Description & View
Part Name Description Ass’y View
① ②

30x50mm
RACK TYPE

①0305 MD
②0305 MDC

50mm
DUCTING - ②
RACEWAY

①05 MDC ③
②05 MD
③05 JOINERS
④SCREW(M3x6)

Cable Diameter : 2.0mm  670(Full load)

100mm ⑤
DUCTING -
RACEWAY

①10 MDC

②10 MD
③10 JOINERS

④SCREW(M3x6)
⑤DUCT CLIP ④

(OPTION +) ③
⑥Rubber
Packing(Ø 6)

Cable Diameter : 2.0mm  1,390

Optical Fiber Raceway Ducting System - 12 OPSYS®


-
Application Guide 2010
Part Name Description Ass’y View
④ ①

160mm
DUCTING -

RACEWAY ⑤

①160 MDC
② ⑦
②160 MD
③160 JOINERS
④SCREW(M3x6) ③
⑤SCREW(M4x10)
⑥DUCT CLIP

(OPTION +)
⑦Rubber
Packing(Ø 6)
Cable Diameter : 2.0mm  2,250

④ ①
220mm
DUCTING -
RACEWAY


①220 MDC
②220 MD

③220 JOINERS
④SCREW(M3x6) ②
⑤SCREW(M4x10)

⑥DUCT CLIP

(OPTION +)
⑦Rubber
Packing(Ø 6)
Cable Diameter : 2.0mm  3,100


300mm ⑥
DUCTING -
RACEWAY ⑦

①300 MDC

②300 MD ⑤
③300 JOINERS
④SCREW(M3x6)
⑤SCREW(M4x10)
⑥DUCT CLIP

(OPTION +)
⑦Rubber Cable Diameter : 2.0mm  4,240
Packing(Ø 6)

Optical Fiber Raceway Ducting System - 13 OPSYS®


-
Application Guide 2010
View
Ass’y
HORIZONTAL CROSS & CROSS COVER
Description

PART W D H REMARK
OP-10CA & OP-10CAC 265mm 265mm 125mm
OP-16CA & OP-16CAC 307mm 307mm 125mm
OP-22CA & OP-22CAC 367mm 367mm 125mm View Sample
OP-30CA & OP-30CAC 447mm 447mm 125mm

Optical Fiber Raceway Ducting System - 14 OPSYS®


-
Application Guide 2010
View
Ass’y
HORIZONTAL TEES & TEES COVER
Description

PART W D H REMARK
OP-10TA & OP-10TAC 265mm 193mm 125mm
OP-16TA & OP-16TAC 307mm 244mm 125mm
OP-22TA & OP-22TAC 367mm 304mm 125mm View Sample
OP-30TA & OP-30TAC 447mm 384mm 125mm

Optical Fiber Raceway Ducting System - 15 OPSYS®


-
Application Guide 2010
View
Ass’y
HORIZONTAL ELBOW & ELBOW COVER
Description

PART W D H REMARK
OP-10HA & OP-10HAC 120mm 193mm 125mm
OP-16HA & OP-16HAC 181mm 291mm 125mm
OP-22HA & OP-22HAC 241mm 352mm 125mm View Sample
OP-30HA & OP-30HAC 321mm 431mm 125mm

Optical Fiber Raceway Ducting System - 16 OPSYS®


-
Application Guide 2010
View
VERTICAL ELBOW DOWN & ELBOW DOWN COVER
Ass’y
Description

PART W D H REMARK
OP-05DA & OP-05DAC 66mm 138mm 56.5mm
OP-10DA & OP-10DAC 120mm 230mm 125mm
OP-16DA & OP-16DAC 181mm 232mm 125mm
OP-22DA & OP-22DAC 241mm 232mm 125mm View Sample
OP-30DA & OP-30DAC 321mm 232mm 125mm

Optical Fiber Raceway Ducting System - 17 OPSYS®


-
Application Guide 2010
View
Ass’y
VERTICAL ELBOW UP & ELBOW UP COVER
Description

PART W D H REMARK
OP-05UA & OP-05UAC 66mm 135mm 56.5mm
OP-10UA & OP-10UAC 120mm 207mm 125mm
OP-16UA & OP-16UAC 181mm 232mm 125mm
OP-22UA & OP-22UAC 241mm 214mm 125mm View Sample
OP-30UA & OP-30UAC 321mm 208mm 125mm

Optical Fiber Raceway Ducting System - 18 OPSYS®


-
Application Guide 2010
View
Ass’y
REDUCER & REDUCER COVER
Description

PART W / W2 D H / H2 REMARK
OP-10RD (100→50) 120mm / 70mm 114.5mm 125mm / 57.5mm
OP-16RD (160→100) 181mm / 121mm 131mm 125mm
OP-22RD (220→160) 241mm / 181mm 147mm 125mm View Sample
OP-30RD (300→220) 321mm / 241mm 156.5mm 125mm

Optical Fiber Raceway Ducting System - 19 OPSYS®


-
Application Guide 2010
View

OP-30TP Cut
TPJO Bonding
Ass’y
OUTLET TRUMPET
Description

PART W / W2 D(T) H / H2 REMARK


OP-05TP 96mm / 50mm 46mm(2.0T) / 54mm
OP-10TP 192mm / 100mm 86mm(3.0T) / 106mm View Sample
OP-16TP(30TP CUT) 260mm / 160mm 80mm(3.5T) 106mm / 200mm
OP-22TP(30TP CUT) 320mm / 220mm 80mm(3.5T) 106mm / 200mm View Sample
OP-30TP 400mm / 300mm 80mm(3.5T) 106mm / 200mm

Optical Fiber Raceway Ducting System - 20 OPSYS®


-
Application Guide 2010

OP-30EC Cut
View

16EC & 10EC


Ass’y
END CAP
Description

PART W D(T) H / H2 REMARK


OP-10EC(30EC CUT) 114.5mm 13mm(3.0T) 127mm / 112.5mm
OP-16EC(30EC CUT) 175.0mm 13mm(3.0T) 127mm / 112.5mm
OP-22EC 233.2mm 19mm(3.0T) 124mm / 108.8mm View Sample
OP-30EC 314.0mm 13mm(3.0T) 127mm / 112.5mm View Sample

Optical Fiber Raceway Ducting System - 21 OPSYS®


-
Application Guide 2010
100 HORIZONTAL TOP & 100 HORIZONTAL TOP COVER
View
Ass’y

OP-10,16,22,30MDC

OP-851(DMTB)
T-BOLT (M6)
Description

Optical Fiber Raceway Ducting System - 22 OPSYS®


-
Application Guide 2010
100 VERTICAL TOP & 100 VERTICAL TOP COVER
View
Ass’y

OP-10,16,22,30MDC

T-BOLT (M6)
Description

Optical Fiber Raceway Ducting System - 23 OPSYS®


-
Application Guide 2010

How to
Connect
Structure
View
Ass’y

SMTB
Composition
SUSPENSION KIT

How to extend
Structure

OP-APP857

OP-APP855

OP-APP856-1
Description

OP-APP854

SMTB(160) T-BOLT (M6)

Optical Fiber Raceway Ducting System - 24 OPSYS®


-
Application Guide 2010
3. OPSYS’s Ducting System DROP KITS

Tee
View
Ass’y

Joiner
TEE TYPE DROP KIT

Down Elbow 90

Trumpet

DOWN
MD TEES +REDUCERS + MD TRUMPET REMARK
45' / 90'
Composition (Drop Tree)

OP-05DA OP-05MD OP-05TP


OP-10MD OP-10TA OP-10RD
OP-10DA OP-10MD OP-10TP

OP-05DA OP-05MD OP-05TP


OP-10RD View
OP-16MD OP-16TA OP-10DA OP-10MD OP-10TP
OP-16RD Sample
OP-16DA OP-16MD OP-16TP

OP-05DA OP-05MD OP-05TP


OP-10RD
OP-10DA OP-10MD OP-10TP
OP-22MD OP-22TA OP-16RD
OP-16DA OP-16MD OP-16TP
OP-22RD
OP-22DA OP-22MD OP-22TP

OP-05DA OP-05MD OP-05TP


OP-10RD
OP-10DA OP-10MD OP-10TP
OP-16RD
OP-30MD OP-30TA OP-16DA OP-16MD OP-16TP
OP-22RD
OP-22DA OP-22MD OP-22TP
OP-30RD
OP-30DA OP-30MD OP-30TP

Optical Fiber Raceway Ducting System - 25 OPSYS®


-
Application Guide 2010

Horizontal Top
Outlet Drop
HORIZONTAL TOP OUTLET DROP KIT
View
Ass’y

Reducer

Down Elbow 90

Joiner

Trumpet

DOWN
MD HT +REDUCERS + MD TRUMPET REMARK
45' / 90'
Composition (Drop Tree)

OP-10MD

OP-16MD
OP-05DA OP-05MD OP-05TP View
OP-10HT OP-10RD
OP-10DA OP-10MD OP-10TP Sample
OP-22MD

OP-30MD

Optical Fiber Raceway Ducting System - 26 OPSYS®


-
Application Guide 2010
View
VERTICAL TOP OUTLET DROP KIT
Ass’y

Vertical Top
Outlet Drop

Reducer

Trumpet

MD VT +REDUCERS + MD TRUMPET REMARK


Composition (Drop Tree)

OP-10MD

OP-16MD
OP-05MD OP-05TP View
OP-10VT OP-10RD
OP-10MD OP-10TP Sample
OP-22MD

OP-30MD

Optical Fiber Raceway Ducting System - 27 OPSYS®


-
Application Guide 2010
4. OPSYS’s Ducting System RACK TYPE KIT
30X50 DUCTING SYSTEM RACK TYPE KIT
View
Ass’y
Description

Optical Fiber Raceway Ducting System - 28 OPSYS®


-
Application Guide 2010
5. General Method for Supporting Opsys’s Ducting System

5.1 How to install Anchor Set in Ceiling

1. Please designate the Anchor set work place for Structure.

Structure standard is 1.5m or 3m.

2,000
FDF

Anchor Set Marking

6,000
for Installation work

2,000
FDF

1,500
2,000 2,000 2,000

8,200

2. Anchor Set work with Suspension Kits Long Type is as follow, and the number in below photo
shows the order in doing assembling.

CEILING

① Drilling in Ceiling

③ Firmly fix Nut of Anchor Set in


using Spanner

② Insert Anchor Set in Drilled


section, and Assembly as like Photo.

Optical Fiber Raceway Ducting System - 29 OPSYS®


-
Application Guide 2010
5.2 Suspension Kit Assembly

1. When installed Ducting System in Ceiling area of telecommunication center, after working Anchor
Set for Structure work, please procedure & assemble Structure as below.

2. The connection between Anchor Set and Suspension Kits uses Long Nut, and please fix strongly.

Ceiling

Suspension Kits

Long Nut

Mounting Bracket
for Structure

3. After assembling Suspension kits, please put Structure, and then firmly fasten the nut of Mounting
Bracket. Further, the Connection among Structure uses Structure Joiner as below.

M8 NUT

Structure Joiner

M8 NUT

Optical Fiber Raceway Ducting System - 30 OPSYS®


-
Application Guide 2010
5.3 How to install the Structure

In case of close distance with Duct and Rack, SUSPENSION KIT has carefully to be installed as below
photo, keeping “A” & “B” space.

RACK

Hex Screw (M8)

NUT

Optical Fiber Raceway Ducting System - 31 OPSYS®


-
Application Guide 2010
5.3 SMTB (Side Mount Bracket) Installation

1. As SMTB gets in touch with Duct items, when assembled, please strongly fix every nut.

Additionally, SMTB interval is 90cm~1.20cm according to installation environment,


but the recommendable distance is every 90cm.

Structure

SMTB

2. How to install beside wall with SMTB

a. Drilling beside wall.


b. Fix SMTB as below photo.
c. Fasten strongly.

SMTB

Optical Fiber Raceway Ducting System - 32 OPSYS®


-
Application Guide 2010
5.4 How to install Suspension Kit by using Existing Ladder Rack

When it is hard to install Anchor set on Ceiling due to existing Ladder Rack, please use Ladder rack bracket
kit as below. The Ladder bracket kit is made up two units of one set.

Ladder Rack

Ladder Rack Bracket Kit

Nut
Ladder Rack Washer
Bushing

Ladder Rack Fixing Side

Nut
Washer
Bushing

Optical Fiber Raceway Ducting System - 33 OPSYS®


-
Application Guide 2010
5.5 How to install UnderFloor with LDRB

LDRB composed 2pcs for 1set is the necessary parts to install Main Duct under floor, and please take note as below
drawing.
First, Properly specify the location for LDRB in Fiber Optic Ducting Layout, and LDRB installation interval according to
installation environment is 90~120Cm to tolerate Main Duct weight. However, the recommendable distance is
every 90cm.
Second, After working the Anchor Set, solidly fix LDRB by using Bolt on the designated place. Then, Main Duct is
fastened by T-Bolt between bottom of Main Duct and top of LDRB.

LDRB (2EA / 1Set)

T- Bolt M12(W1/2)
Hex Head Bolt

M12(W1/2)
Set Anchor

LDRB is designed as adjustable assembly parts with considering the limited height at working place.
Assembling Sequence for LDRB is as below.

M10
Hex Head NUT

M10
Hex Head Bolt

Optical Fiber Raceway Ducting System - 34 OPSYS®


-
Application Guide 2010
6 OPSYS’s Ducting System Overall View
DUCTING SYSTEM OVERALL VIEW

OPSYS Co.,Ltd
Headquarters : #959-40, HighTech Center, DaeChon-Dong, Buk-Gu, KwangJu City, Korea
Tel : +82 62 971 5959 Fax : +82 62 971 8482
Factory / WareHouse : #149-1, NongSo-Ri, JuChon-Myeon, GimHae City, Korea
Tel : +82 55 334 8335~6 Fax : +82 55 334 8334

WWW.OPSYS4U.CO.KR

Optical Fiber Raceway Ducting System - 35 OPSYS®


-
Application Guide 2010

Optical Fiber Raceway Ducting System - 36 OPSYS®


-

Вам также может понравиться