2. Definitions and Designations
Alternative types and layouts
Design Seating Total efficiency (%)
of shaft generator
Basically, MAN B&W Diesel distinguish
between three main categories of shaft On engine
1 BW I/GCR (vertical generator) 92
generators:
Constant Ratio):
Consists of flexible coupling, step-up 3 BW III/GCR On engine 92
gear, torsionally rigid coupling, and al-
ternator.
4 BW IV/GCR On tanktop 92
2 PTO/RCF (Power Take Off/Renk
On engine
Constant Frequency): 5a 5b BW I/RCF 8891
(vertical generator)
Consists of flexible coupling, step-up
gear, torsionally rigid couplings, RCF- On tanktop
6a 6b BW II/RCF (vertical generator) 8891
PTO/RCF
The designations BW I ... BW IV are used In MAN B&W Diesel terms, a 700 kW (60 In the following chapters, the three
to distinguish between the various physi- Hz) shaft generator of the GCR type in- types of PTO (PTO/GCR, PTO/RCF,
cal configurations of the shaft generator tended for installation at the side of an PTO/CFE) and the various possibilities
system. S50MC-C engine is thus designated: for the configuration of the PTO (BW I
... BW IV) are described.
BW III S50-C / GCR 700 - 60
4
3. Categories of Shaft The total efficiency of the PTO/GCR is 3.2 PTO/RCF (Power Take Off /
Generators around 92%. Renk Constant Frequency)
3.1 PTO/GCR (Power Take Off / Except for the PTO BW I/GCR and the
Gear Constant Ratio) PTO BW III/GCR, which are built directly The PTO/RCF includes an RCF speed
onto the main engine, and is only produced controlled planetary gearbox developed
The PTO/GCR is the simplest shaft genera- by Renk in Germany, several manufacturers by Renk, and the system is only available
tor, as no speed control or frequency control are able to supply the PTO/GCR system. from Renk. Figure 2 illustrates the design
systems are incorporated. In the vast ma- Prices vary greatly with the physical configu- principles of the RCF gearbox.
jority of cases, the PTO/GCR is used to pro- ration of the system and the different suppli-
duce electric power with a constant electri- ers. The investment cost of a PTO/GCR is The RCF gearbox is an epicyclic gear
cal frequency during the voyage. Since the much smaller than the cost of a PTO/RCF with a hydrostatic superposition drive.
frequency produced by the alternator is pro- or a PTO/CFE. On the other hand, the in- The superposition drive comprises a hy-
portional to the speed of the engine, the en- vestment cost of the controllable pitch pro- drostatic motor controlled by an elec-
gine must be operated at constant speed. peller required in combination with a PTO/ tronic control unit and driven by a built-on
This is only possible if a controllable pitch GCR is higher than the cost of a fixed pitch pump.
propeller is installed. When a fixed pitch pro- propeller.
peller is used, the speed of the propeller, The hydrostatic system drives the annu-
and thus of the engine, varies with the re- Finally, the operation of the engine at con- lus of the epicyclic gear in either direction
quired speed of the ship and the resistance stant speed means reduced propeller effi- of rotation, based on the detected output
acting on the ship. ciency at reduced propulsion load com- speed, and thus continuously varies the
pared with a controllable pitch propeller run- gear ratio over an engine speed variation
Alternatively, the PTO/GCR can be used for ning in combinator mode (reduced speed at of 30%. In the standard layout the con-
power production with floating frequency, reduced propulsion load) or a fixed pitch pro- stant output speed range of the gearbox
e.g. between 50 and 60 Hz, which means peller. The thermal efficiency of the main en- is set between 100% and 70% of the en-
that the speed of the main engine is allowed gine is also slightly lower in constant speed gine speed at specified MCR.
to vary between 83% and 100% of the mode than in combinator mode.
speed at specified MCR (Maximum Con-
tinuous Rating). This also means that certain
power consumers sensitive to frequency
variations must be provided with power sup-
ply via a frequency converter or from a
genset. The concept of long-term running To panel
with floating electrical frequency is only used
in rare cases. Hydrostatic Operator control panel
control (in switchboard)
5
An electronic control system ensures that
the control signals to the main electrical Mains, constant frequency
switchboard are identical to those of the
gensets, and the PTO/RCF is able to op-
erate alone or in parallel with the gensets
throughout the complete constant output Synchronous
speed range of the gearbox. The PTO/ Excitation condenser
RCF is therefore suitable for installation on converter G
ships with a fixed pitch propeller.
The PTO/CFE can, alternatively, be made The total efficiency of the slow running
as a slow-running alternator coupled di- PTO/CFE types varies between 84% and
rectly to the front end of the engine 88%.
(DMG/CFE, Direct Mounted Generator)
or installed with the rotor integrated into
the intermediate shaft (SMG/CFE, Shaft
6
4. Physical Configuration
Additionally, the toothed coupling allows Fig. 4: PTO BW I S70/RCF 850-60 (Renk)
simple separation of the complete gear unit
from the Geislinger coupling, and thus the
crankshaft, by shifting the shaft which car- only loaded by the weight of the Geislinger In the case of the PTO BW I/RCF the RCF
ries the main gear wheel forward in the coupling. gear is integrated into the step-up / bevel
axial direction. This procedure for discon- gear unit and because the hydrostatic drive
nection is only to be used in the special A multi-disc clutch is built into the RCF of the RCF gear requires a 5 µm filtration of
event that it is required to completely dis- gearbox input shaft and ensures that the the oil, the complete gear unit has a sepa-
connect the gear unit from the main en- epicyclic RCF gear (if included) and the al- rate lubricating oil system including the oil
gine. ternator, can be engaged or disengaged supply to the Geislinger coupling.
during operation of the main engine.
Around the Geislinger coupling, between
the crankcase space and the gear unit, An electrically driven built-on lubricating oil
space is available for a tuning wheel, stand-by pump supplements a gear driven
a moment compensator or a torsional vi- pump when the engine is started and in the
bration damper, if required. event of malfunctioning of the gear driven
pump.
The gear unit, often referred to as a “crank-
shaft gear”, is bolted to the bedplate and The PTO/RCF can be operated on the
framebox of the engine, and the weight of same type of oil as is used for the main en-
the gear wheels is, via bearings installed in gine lubricating oil system if the lube oil meets
the gearbox, transferred to the engine a minimum load level of 8 according to the
structure. Consequently, the crankshaft is standardised FZG Gear Test (DIN 51354).
7
For the PTO BW I/RCF, the shipyard
must provide cooling water for the built-
PTO BW IV/GCR
PTO BW III/GCR
PTO BW IV/RCF
PTO BW III/RCF
PTO BW II/GCR
PTO BW II/RCF
PTO BW I/GCR
PTO DMG/CFE
PTO BW I/RCF
PTO SMG/CFE
on lubricating oil cooler, electric power
supply to the built-on lubricating oil stand-
by pump, and cabling between the alter-
nator and the switchboard. We further
recommend that the shipyard installs an
external lubricating oil filling system, in-
cluding a dosage tank made in accor- Cooling water supply to lub. oil
x x x x x x
dance with the specified volume of oil cooler
used for one gearbox oil change. See
Figure 5. Cooling water supply to alternator
(x) (x)
- if water cooled type is applied
The PTO BW I/GCR is lubricated and Lub. oil dosage tank (option) (x) (x) (x) (x)
cooled by using the main engine lubri-
cating oil system and it has to be ensured Electric power supply to lub. oil
x x x x x x x x
that the lube oil has a minimum FZG load stand-by pump
level of 8. This means that the cooling
Cabling between alternator and
water supply and the external lubricating x x x x x x x x
switchboard
oil filling system can be dispensed with. In
this case, the capacities of the main External wiring of control system x x x x
engine’s lubricating oil system with related
coolers must be increased in accordance Electric cabling x x
with the data given by the supplier of the Seating for gearbox x x x x
shaft generator. The shipyard has to ar-
range the external wiring of the control Seating for support bearing (x) (x)
system. The PTO BW I/GCR has not yet
Seating for alternator x x
been produced.
Seating for synchronous condenser
The following preparations for the installa- x x
unit
tion of the PTO system must be made on
the engine. See also Figure 6. Seating for static converter cubicles x x
8
4.2 Front end installation (BW II)
PTO BW IV/GCR
PTO BW III/GCR
PTO BW IV/RCF
PTO BW III/RCF
PTO BW II/GCR
PTO BW II/RCF
PTO BW I/GCR
PTO DMG/CFE
PTO BW I/RCF
PTO SMG/CFE
The PTO BW II is placed in front of the
engine but, in contrast to the PTO BW I,
the gear unit is seated on a separate
foundation on the tanktop.
9
Figure 7 shows a space optimised con-
cept where the alternator is placed ho- Alternator Torsionally Stepup
rizontally between the step-up gearbox rigid gear
and the front end of the engine and thus coupling
utilises the space which is anyway taken
up by the flexible coupling.
Alternator
Flexible
coupling
Stepup
gear
10
Often a small support bearing has to be 4.3 Side mounted installation (BW III) The gear unit, often referred to as a
installed between the front end of the en- “crankshaft gear”, is bolted to the bed-
gine and the flexible coupling. Whether a The investment cost of the PTO BW III is plate and framebox of the engine, and
support bearing is required can be deter- typically higher than for the other gear the weight of the gear wheels is, via
mined from MAN B&W Diesel’s specifica- based shaft generators. However, we bearings, installed in the gearbox, trans-
tion of the permissible shear force and have adopted it as our standard, as it is ferred to the engine structure. Conse-
bending moment on the front end of the the most compact system available, quently, the crankshaft is only loaded by
crankshaft. which means more space for cargo the weight of the Geislinger coupling.
transportation, and a further advantage is
The PTO BW II has its own lubricating oil that it is easy to install at the shipyard. The step-up gear of the PTO BW III/
system, and an electrically driven built-on GCR is lubricated and cooled using the
lubricating oil stand-by pump supple- The gearbox is available as standard for main engine lubricating oil system, so it
ments a gear driven pump at start of the the 42 MC engines and upwards includ- requires no cooling water supply. The ca-
engine and in the event of malfunctioning ing the ME engines. Standard sizes of al- pacities of the main engine’s lubricating oil
of the gear driven pump. ternators are 700, 1200, 1800 and 2600 system with related coolers are to be in-
kW, but others are available on request. creased accordingly. A minimum FZG
The gearbox and the support bearing are load level of 8 has to be observed for the
seated on the tanktop, and the shipyard In the BW III system, the step-up gear lube oil.
has to make suitable foundations. The unit is bolted directly to the engine front
shipyard must also provide cooling water end face, and is designed to allow the al- A multi-disc clutch can be built into the
for the built-on lubricating oil cooler, elec- ternator to be placed horizontally at the gearbox output shaft ensuring that the al-
tric power supply to the built-on lubricat- side of the engine. See Figure 9, which ternator can be engaged or disengaged
ing oil stand-by pump and cabling be- shows the PTO BW III/GCR. This com- during operation of the main engine. The
tween the alternator and the switch- pact design gear unit is only available required operating oil pressure for the
board, as well as external wiring of the from Renk. multi-disc clutch is supplied by a gear
control system (except for the PTO BW driven pump. On engine start-up and in
II/RCF). A Geislinger elastic damping coupling is the event of malfunctioning of the gear
included in the delivery. The Geislinger driven pump, an electrically driven built-on
For the PTO BW II/RCF we recommend coupling is described in Section 4.1. lubricating oil stand-by pump supple-
that the shipyard installs an external lubri- ments the gear driven pump.
cating oil filling system, including a dosage
tank made in accordance with the speci-
fied volume of oil used for one gearbox oil
change.
Brackets
Bedframe
11
Operator
control
panel
Combined
Alternator Geislinger
and toothed
Controller coupling
Crankshaft gear
Bedframe Brackets
RCF unit
incl. multi Toothed coupling
disc clutch
The step-up gear (crankshaft gear) of For the PTO BW III/RCF the shipyard system or the PTO BW III/RCF system
the PTO BW III/RCF is, similar to the must provide cooling water for the must be made on the engine:
crankshaft gear of the PTO BW III/GCR, lubricating oil cooler built on to the RCF
lubricated and cooled by using the main gear, electric power supply to the • three machined blocks welded on to
engine lubricating oil system. Figure 10 lubricating oil stand-by pump built on to the front end face for alignment of the
shows the PTO BW III/RCF. the RCF gear, and cabling between the gear unit
alternator and the switchboard. We • machined washers to be placed
The RCF gear, placed at the side of the further recommend that the shipyard between the gearbox and the frame-
engine, can be operated on the same installs an external lubricating oil filling box to compensate for the small dif-
type of oil as the main engine lubricating system, including a dosage tank made in ference in length between the bed-
oil system. However, the hydrostatic accordance with the specified volume of plate and the framebox
drive of the RCF gear requires a 5 µm oil used for one RCF-gear oil change. • rubber gasket to be placed between
filtration of the oil, and the RCF gear, the gearbox and the framebox
consequently, has its own lubricating oil The PTO BW III/GCR only requires • electronic axial vibration measuring
system. electric power supply to the built-on system
lubricating oil stand-by pump and • free flange end on lubricating oil inlet
A multi-disc clutch is built into the RCF cabling between the alternator and the pipe
gearbox, and an electrically driven switchboard as well as external wiring • oil return flange welded on to bed-
lubricating oil stand-by pump, built on to of the control system. plate
the RCF gear, supplements a gear • brackets mounted on starboard side
driven pump on engine start-up and in The following preparations for the of bedplate to support the RCF gear
the event of malfunctioning of the gear installation of the PTO BW III/GCR (if installed) and the alternator.
driven pump.
12
4.4 Aft end installation (BW IV) mediate shaft flange at the engine aft end alternator. The shipyard must also pro-
and the hollow shaft of the tunnel gear- vide cooling water for the built-on lubri-
The PTO BW IV is placed aft of the en- box. Some of the steel flanges used for cating oil cooler, electric power supply for
gine and is made as a tunnel gear with a the coupling are made in halves to allow the built-on lubricating oil stand-by pump,
hollow shaft, which allows the intermedi- them to be assembled around the shaft. and cabling between the alternator and
ate shaft, including the flange, to pass the switchboard, as well as external wir-
through, see Figure 11. The flexible coupling only transfers the ing of the control system (except for the
torque corresponding to the power of the PTO BW IV/RCF).
A number of gearbox manufacturers are shaft generator, since the intermediate
able to supply the PTO BW IV/GCR, shaft for the propeller is bolted directly to No preparations for the installation of the
whereas only Renk is able to supply the the thrust shaft of the engine. PTO system are needed on the engine,
PTO BW IV/RCF, although it has not yet but the intermediate shaft flange must be
been produced. The PTO BW IV has a separate lubricat- provided with additional bolt holes for the
ing oil system, and an electrically driven flexible coupling.
The PTO BW IV can often be installed built-on lubricating oil stand-by pump
within the space already available around supplements a gear driven pump on en-
the shaftline aft of the engine, without in- gine start-up and in the event of any mal-
creasing the total building-in length. functioning of the gear driven pump.
Vulkan Rato
flexible coupling
Toothed
coupling
Alternator
Tunnel
gear
13
Static frequency converter system
Distribution cubicle To
Synchronous switchboard
condenser Converter cubicle
Excitation cubicle
Control cubicle
Cooler
Stator housing
4.5 Front end installation (DMG/CFE) support bearing to reduce the load on the Since the frequency converter system
crankshaft. uses a DC intermediate link, it can supply
The PTO DMG/CFE is a large slow- no reactive power to the main switch-
running alternator with its rotor mounted The electrical frequency generated de- board. A synchronous condenser is used
directly on the crankshaft and its stator pends on the speed of the main engine to supply this reactive power. The syn-
housing bolted to the front end face of and the number of poles. Since the size chronous condenser consists of an ordi-
the engine. The PTO DMG/CFE does not of the alternator, and thus the number of nary synchronous alternator.
include a gearbox, and no flexible cou- poles, is limited by the ship’s hull, it is not
pling is required. See Figure 12. The alter- possible, with the low speed of the two- The DMG/CFE is normally able to oper-
nator is separated from the crankcase by stroke engine, for the alternator itself to ate in parallel with the gensets at the full
a plate and a labyrinth seal. produce electricity with a frequency of rated electric power, when the speed of
50 Hz or 60 Hz. It is therefore necessary the main engine is between 75% and
If the torsional characteristics of the shaft to use a static frequency converter sys- 100% of the engine speed at specified
system require the application of an addi- tem between the alternator and the main MCR. Between 40% and 75% of the
tional inertia mass on the crankshaft fore switchboard. SMCR speed, the electric output of the
end, a tuning wheel can be installed, as DMG/CFE is reduced proportionately to
illustrated in Figure 13. A front end The static frequency converter system, the engine speed.
mounted moment compensator or a tor- see Figure 12, consists of a static part,
sional vibration damper may be installed i.e. thyristors and control equipment, and The shipyard must provide seating for the
in a similar way. a rotary electric machine (synchronous synchronous condenser unit and the
condenser). static converter cubicles, as well as cool-
If the limits for shear force and bending ing water, if a water cooled alternator is
moment acting on the fore end flange of The three-phase alternating current is used, and electric cabling.
the crankshaft are exceeded, the stator rectified and conducted to a thyristor in-
housing must be made with a front end verter producing a three-phase alternat-
ing current with constant frequency.
14
price and a more straightforward design
Air Stator housing Air Stator housing with no physical interface with the main
cooler Stuffing box cooler Stuffing box engine.
Crankshaft Crankshaft
In addition to the shipyard installations
mentioned in Section 4.5 for the PTO
DMG/CFE, the shipyard must provide the
Support
bearing
foundation for the stator housing in the
case of the PTO SMG/CFE.
Pole
wheel The engine needs no preparation for the
installation of this PTO system.
15
5. Layout of Engine with Shaft erator can be found on the basis of the In most cases, the SMCR of an engine
Generator propeller design point (PD) by incorporat- with a shaft generator is found by adding
ing the following factors, please refer to the maximum power consumed by the
Beyond the physical preparations of the Figure 15: shaft generator to the specified propulsion
engine for the installation of a shaft gen- MCR point (MP). See Figure 16.
erator, the layout of the engine in terms • light running factor (normally 3-7% of
of power and speed is also affected by the engine speed at PD is deducted) Consequently, the engine with a shaft
the decision to install a shaft generator. • sea margin (traditionally 15% of the generator is specified with the maximum
power at PD is added – following the continuous rating (M), and the optimising
As an example the following describes heavy running propeller curve and giv- point (O), located on a propeller curve
how the installation of a shaft generator ing the service propulsion point SP = placed to the left of the propeller curve
on an engine intended to drive a fixed S) (through MP) for heavy running propulsion
pitch propeller influences the layout of the • engine margin (typically 10% of the without a shaft generator.
engine: power at MP = M = SMCR is added
to the power at SP = S – following
The specified maximum continuous rating the heavy running propeller curve).
(SMCR) of an engine without a shaft gen-
Power
2 Heavy propeller curve –
fouled hull and heavy weather
6 Light propeller curve –
clean hull and calm weather
MP: Specified propulsion MCR point
MP
SP: Service propulsion point
Engine margin
PD: Propeller design point
(10% of MP) SP PD´: Alternative propeller design point
PD´
Sea margin LR: Light running factor
(15% of PD) HR: Heavy running
PD
LR(5%)
2 6 HR
Engine speed
16
The above means that the installation of
a shaft generator may involve that an en-
gine with one more cylinder must be se-
lected to ensure that the SMCR point is
placed inside the top of the layout dia-
gram. However, this, of course, entails
extra costs and additional space require-
ments for the main engine.
Propulsion curve
for heavy running Line 1: Propeller curve through optimising point (O)
Engine service curve Line 7: Constant power line through specified MCR (M)
for heavy running
Engine speed Point A: Intersection between lines 1 and 7
17
6. Torsional Vibration As a rule of thumb, the lowest natural fre- but, because of the inertia of the rotor,
quency of the shaft generator branch they may naturally influence the torsional
6.1 Engines with small shaft should not be less than 120%, or more layout of the shafting.
generators than 80%, of the frequency correspond-
ing to the main engine speed at specified 6.2 Engines with large shaft
The gear based shaft generator systems MCR. This means that either undercritical generators
(PTO BW I ... BW IV) all incorporate a or overcritical vibration conditions for 1st
flexible coupling to protect the gears order excitation are obtained, with a sat- Certain types of ships, such as shuttle
against hammering caused by torsional isfactory safety margin. tankers with high electricity consumption,
excitation from the engine. may use one or more large shaft genera-
If a clutch for the alternator is incorpo- tors for the electricity production. The
Normally, when the power output of the rated in the PTO/GCR, the tuning of the propulsion arrangement of a shuttle
shaft generator is less than 10 per cent of PTO system is normally made as follows: tanker with a large shaft generator nor-
the main engine power, the vibration mally comprises a controllable pitch pro-
modes of the shaft generator system will • Alternator engaged: peller and a shaft clutch. See Section
not influence the vibration modes of the Overcritical running (1st order critical 11.1.
propulsion shaft system. This means that speed at 55 - 80% x SMCR speed)
the main propulsion shaft system can be The torsional vibrations of such an instal-
designed and determined regardless of • Alternator disengaged lation are very complex, and require care-
whether a shaft generator is to be in- Undercritical running (1st order critical ful investigation of all possible operation
stalled later on. speed above 120% x SMCR speed, modes during the design stage.
higher orders to be considered).
The PTO/GCR is normally designed to In general, the elastic coupling, or coup-
operate at 100% of the speed at spe- The ideal way of tuning the PTO/RCF, lings, should be sufficiently flexible to en-
cified MCR, and is therefore tuned so which is normally designed to operate be- sure a natural frequency in the shaft gen-
that the critical speed of significant T/V- tween 70% and 105% of the engine erator system below 75% of the fre-
orders is placed outside the range 80 - speed at specified MCR, is to have a flex- quency which corresponds to the main
120% of the speed at specified MCR. ible coupling which leads to a natural fre- engine speed to be used for operation of
quency, around 50 - 60% of the fre- the shaft generator.
Normally, the flexible couplings for the quency which corresponds to the speed
PTO/GCR types are selected on the ba- at specified MCR. Alternatively, the shaft generator system
sis of the misfiring conditions, and the can be designed to have a natural fre-
normal service conditions will, conse- Should the natural frequency be higher, quency of approximately 150% of the fre-
quently, usually be harmless to the flexible because of a more rigid coupling, the al- quency which corresponds to the main
coupling and the gear. ternator must be declutched in the event engine operating speed.
of misfiring. The PTO/RCF is always
In cases of misfiring, the 1st order excita- made with a clutch built into the RCF The above will give main critical reso-
tion, which normally has a frequency gear, and operation during misfiring is of- nances in the shaft generator system
close to the natural frequency of the 1- ten prohibited. In this case, the magni- (4th, 5th and 6th order) at very low speed
node vibration mode (the lowest natural tude of the alternator’s inertia must, or even below the minimum speed. Fur-
frequency) occurring in the shaft genera- when the alternator is declutched, permit thermore, the 1st and 2nd order excita-
tor branch, increases substantially, irre- the natural frequency of the shaft genera- tion, which becomes dominant in case of
spective of the number of cylinders of the tor branch which remains coupled to the misfiring, will have resonance outside the
engine. This explains why it is essential to engine, to ‘jump’ to a sensibly higher fre- shaft generator operating speed. Such
tune the natural frequency of the 1-node quency than the frequency which corre- tuning of the natural frequencies will nor-
vibration mode in accordance with the sponds to 105% of the speed at specified mally require very elastic couplings.
engine speed. MCR. In order to obtain this, it may be
necessary to tune the inertia of the alter-
The position of the natural frequency for nator by fitting an additional mass (tuning
the 1-node vibration mode in the shaft wheel) at the alternator side of the clutch.
generator branch mainly depends on the
flexible coupling’s torsional flexibility and The DMG/CFE and the SMG/CFE do not
the inertia of the alternator. incorporate a gear or a flexible coupling
18
7. Engine Governing System For the electronically controlled ME en- • Reliability
gine, the governor functions are included Shaft generators are normally consid-
in the Engine Control System and the ered highly reliable, as is the main en-
Basically, the following three types of gov- control of an ME engine with shaft gen- gine which drives the shaft generator
ernors can be used to control modern erator is comparable to the control of a
two-stroke camshaft diesel engines: camshaft controlled diesel engine with • Low man-hour cost for maintenance
shaft generator and electronic governor. The planned maintenance of a shaft
• conventional electronic governor with generator during the first years of op-
one speed pick-up and standard soft- 8. Pros and Cons (shaft eration only involves regular checks of
ware generators versus gensets) proper functioning and regular re-
• advanced electronic governor with placement of the lubricating oil and
two or more speed pick-ups and spe- In the following, a number of advantages the oil filter, if the shaft generator has
cial software and disadvantages related to the use of a separate lubricating oil system
• mechanical-hydraulic governor (for shaft generators are discussed:
small bore engines only). • Low spare parts cost
8.1 Advantages – shaft generators The high reliability of shaft generators,
The mechanical-hydraulic governor can together with the low spare parts
be used for simple installations involving • Small space requirement consumption for planned mainte-
the 26-46MC engines, where it may pro- The shaft generator is installed close nance, result in low spare parts costs
vide sufficient governing abilities at an at- to the engine or the shaft line, and of-
tractive cost. However, an electronic ten takes up no further space than is • Long lifetime
governor is also often used for the 26- already set aside for the engine instal- A shaft generator is generally not ex-
46MC engines. All 50-98MC engines re- lation. In particular, the PTO BW III posed to much wear, but of course
quire an electronic governor. (engine side mounted) and the PTO components such as bearings, me-
BW IV (tunnel gear) require little chanically driven oil pumps, friction
The installation of a shaft generator with space for the installation. The SMG/ clutches, etc. need to be replaced or
an electric output power of less than CFE and the DMG/CFE need extra reconditioned after many years in op-
15% of the main engine’s power at space elsewhere in the engine room eration
specified MCR does not normally require for the synchronous condenser and
special considerations in the selection of the control cubicles • Low noise
governor. However, if a PTO/GCR is in- The noise level of a shaft generator is
stalled together with a controllable pitch • Low investment cost (PTO/GCR) considerably lower than the noise
propeller, it may prove advantageous to The investment cost depends on the level of a genset.
use an electronic governor even on the type and make of the shaft generator.
smallest engine types to obtain the most Depending on the origin of the shaft 8.2 Disadvantages – shaft
stable engine speed conditions and, generator, the PTO/GCR can be pur- generators
hence, the most stable frequency in the chased at a relatively low price,
generated electricity. whereas the frequency controlled • No power production in harbour
types (PTO/RCF and PTO/CFE) are Whether a shaft generator is installed
For large shaft generators, the combina- relatively expensive or not, the electric power consump-
tion of a low natural frequency and a high tion in harbour will generally have to
moment of inertia in the alternator may • Low installation cost be covered by a genset. However, in
require special facilities in the engine gov- The shaft generator requires no sepa- special cases where a clutch is in-
ernor (i.e. the advanced governor) if insta- rate (or only a simple) foundation, no stalled in the shaft line, as on shuttle
bilities in the system are to be avoided. exhaust gas system and only a few tankers with high electricity consump-
For plants where the output power of the connections to the auxiliary equip- tion for cargo pumping, it is possible
shaft generator exceeds 15% of the main ment. Furthermore, the time spent in- to use the main engine and the shaft
engine’s power, or a clutch or a flexible stalling a shaft generator is normally generator for electric power produc-
coupling is installed in the shaft line, we short tion in harbour
therefore recommend investigating
whether an advanced electronic gover-
nor is needed.
19
• Higher load on main engine 9. Economic Comparison
The load on the main engine, and
thus the specific fuel oil consumption
and the cylinder oil consumption, in- On the basis of the following data we have compared the operating costs, with and
crease when a shaft generator is without a shaft generator, of a typical feeder container vessel.
used
The following alternatives have been compared:
• Reduced propeller and engine effi-
ciency at low propulsion power for Alternative 1: 1 x 7S50MC-C + PTO BW IV GCR/1200 +
PTO/GCR 2 x 7L16/24H
If the PTO/GCR is used for power
production with a fixed frequency, Alternative 2: 1 x 7S50MC-C + 3 x 7L16/24H
which is usually the case, the engine
with a controllable pitch propeller We have used the following ratings of the main engines:
must be operated at constant speed
even at reduced load. The efficiency Alternative 1: SMCR = 11,060 kW at 127 rpm
of the controllable pitch propeller and CP-Propeller running at constant speed
the engine would be higher if the en-
gine was operated according to a Alternative 2: SMCR = 9,760 kW at 127 rpm
combinator curve, where the speed CP-Propeller running at combinator curve
was reduced at reduced load
Propulsion load profile, Alternative 2:
• No long-time parallel running ability
for PTO/GCR • 90% load for 15% of time at sea
The PTO/GCR cannot run in parallel • 80% load for 40% of time at sea
with the gensets except during load • 70% load for 35% of time at sea
take-over. This means that the power • 50% load for 10% of time at sea
distribution between the electric
power producers is not as flexible as In order to compare two vessels operating at exactly the same speed, the propulsion
with a pure genset installation loads for Alternative 1 have been increased to compensate for the reduced propeller
efficiency at part load, caused by the propeller operating at constant speed.
• More complex shaft arrangement
The installation of a shaft generator Time at sea: 250 days/year
complicates the shaft arrangement.
Gears and flexible couplings need not Time in harbour: 115 days/year
be installed for a two-stroke diesel
engine used for propulsion if a shaft Electric load at sea: 900 kW
generator is not installed.
Electric load in harbour: 500 kW
We have compared the two alternatives with respect to fuel oil costs and lubricating oil
costs and found the following result:
20
Additionally, we have analysed the maintenance costs for the two alternatives and estimate
that the average annual maintenance costs for a long operating period are as follows:
Alternative 1:
Alternative 2:
The maintenance costs include man- However, the investment costs for the
hours for overhaul with an hourly wage of shaft generator and the genset may differ
30 USD, and spare part costs in accor- significantly depending on the origin of the
dance with normal overhaul intervals. The shaft generator and the genset.
maintenance costs also allow for 30%
extra man-hours for unscheduled over- The installation costs may be expected to
hauls. favour the shaft generator.
When the additional fuel and lube oil Other aspects also need to be consid-
costs and the expected savings in main- ered, e.g. in some cases a shaft genera-
tenance costs are compared, Alternative tor cannot be installed unless the engine
1 turns out to be 10,500 USD cheaper in is specified with one additional cylinder.
operation per year than Alternative 2. The extra costs for the engine and its
However, the saving only represents auxiliary equipment related to an addi-
around 1.0% of the total annual operating tional cylinder, together with the eco-
costs. nomic impact of an increased engine
room length, have not been evaluated.
Assuming a 30,000 USD extra invest-
ment cost for the shaft generator com- To conclude, many factors influence the
pared with one extra 7L16/24H genset, final economic result, and the final con-
the calculation shows a payback time for clusion as to whether the installation of a
Alternative 1 (with shaft generator) of shaft generator is attractive or not can
three years, using the Net Present Value only be made by the owner.
method with a 3% rate of inflation and a
6% rate of interest.
21
Machinery arrangement Load pattern
7S50MC-C with PTO Load case 1 2 3 4 5
SMCR (kW) 11,060 Hours 900 2,400 2,100 600 2,760
Efficiency PTO (%) 92 Propulsion power (kW) 8,780 7,833 6,916 5,142 0
2 x 7L16/24H gensets PTO mech. power (kW) 975 975 975 975 0
Main engine power (kW) 9,755 8,808 7,891 6,117 0
Basic data MEP (bar) 16.8 15.1 13.6 10.5 0
Total days at sea 250 SFOC (g/kWh) 168.4 168.0 168.2 170.4 0
Total days in harbour 115 Genset power (kW ) 0 0 0 0 500
el
HFO price (USD/ton) 140
System oil price (USD/ton) 800 Fuel oil consumption
Cylinder oil price (USD/ton) 900 Load case 1 2 3 4 5 Total Cost (USD)
Hours 900 2,400 2,100 600 2,760
Main engine power (kW) 9,755 8,808 7,891 6,117 0
SFOC (g/kWh) 168.4 168.0 168.2 170.4 0
Genset power (kWel) 0 0 0 0 500
SFOC (g/kWh ) 0 0 0 0 202
el
HFO (tons/year) 1,571 3,773 2,961 664 296 9,265 1,297,100
(SFOC: ref. LCV = 42,700 kJ/kg)
(HFO: ref. LCV = 40,200 kJ/kg)
Cylinder oil consumption (based on 1.02 g/kWh and Alpha ACC with 3% sulphur)
22
Machinery arrangement Load pattern
7S50MC-C without PTO Load case 1 2 3 4 5
SMCR (kW) 9,760 Hours 900 2,400 2,100 600 2,760
Efficiency PTO (%) – Propulsion power (kW) 8,784 7,808 6,832 4,880 0
3 x 7L16/24H gensets PTO mech. power (kW) 0 0 0 0 0
Main engine power (kW) 8,784 7,808 6,832 4,880 0
Basic data MEP (bar) 16.2 14.8 13.2 9.9 0
Total days at sea 250 SFOC (g/kWh) 166.6 165.5 164.9 168.6 0
Total days in harbour 115 Genset power (kW ) 900 900 900 900 500
el
HFO price (USD/ton) 140
System oil price (USD/ton) 800 Fuel oil consumption
Cylinder oil price (USD/ton) 900 Load case 1 2 3 4 5 Total Cost (USD)
Hours 900 2,400 2,100 600 2,760
Main engine power (kW) 8,784 7,808 6,832 4,880 0
SFOC (g/kWh) 166.6 165.5 164.9 168.6 0
Genset power (kWel) 900 900 900 900 500
SFOC (g/kWh ) 205 205 205 205 202
el
HFO (tons/year) 1,576 3,765 2,925 642 296 9,204 1,288,560
(SFOC: ref. LCV = 42,700 kJ/kg)
(HFO: ref. LCV = 40,200 kJ/kg)
23
10. Typical Applications 11.Special Applications The large side thruster power installed on
the vessels calls for equipment that can
At present, the following shaft generators 11.1 Shuttle tankers provide sufficient electricity production.
are most frequently installed: This means that large diesel generators
Shuttle tankers, which load their cargo or large shaft generators need to be in-
PTO BW II/GCR from storage facilities at the field or di- stalled on all shuttle tankers intended for
rectly from the production platform, are dynamic positioning operation. In order to
PTO BW III/GCR widely used to serve offshore oil fields minimise the total installed power of the
from which pipeline connections are not auxiliary power producers, cargo pumps
PTO BW IV/GCR practicable. driven by electric motors are normally in-
stalled. The cargo pumps are primarily
PTO SMG/CFE High performance manoeuvring equip- used to unload the cargo in port but may
ment is made necessary by the operating also be used in the field to distribute oil
The PTO BW II/RCF and the PTO BW III/ profile which, during loading of the ship, among the segregated cargo tanks. The
RCF are also installed from time to time. includes long periods of accurate dy- maximum power consumption of the
namic positioning at the field, by using cargo pumps is typically around 4-5,000
Typically, the PTO BW II/GCR and the bow and stern thrusters as well as the kW.
PTO BW IV/GCR are used on container main propeller. The time required for load-
vessels or chemical tankers with 26- ing the oil depends on the loading facilities One propulsion system which meets the
50MC main engines (and CPP). The elec- and may vary from one to ten days in above-mentioned requirements is the
trical output power is normally between each round trip. diesel-mechanical system with two low
500 and 1200 kW. The PTO BW III/GCR speed main engines and shaft genera-
is mostly used for the same ship types Shuttle tankers with 3 x 1750 kW bow tors. Figure 19 shows an example of
with 50-60MC main engines (and CPP), thrusters and 2 x 1750 kW stern thrust- such an arrangement, where the shaft
and the shaft generator normally has an ers to match the above requirements are generators are placed in the shaftlines.
electrical output power between 700 and in operation.
1800 kW.
Fig. 19: Shuttle tanker engine room arrangement with shaft generators
24
Clutches are installed in the shaftlines aft ertia of the alternator as well as require- A frequency converter laid out for the
of the shaft generators, and are used to ments for the control of the main engine, ship’s power consumption is required
disconnect the propeller from the main such as an advanced electronic governor where the shaft generators are to be
engine while in port, so that the main en- and an additional overspeed shut-down used for power supply for the general
gine can be used for electric power pro- system controlling a fuel cut-off device. electrical consumption of the ship in all
duction without turning the propeller. As an additional safety feature it is rec- load conditions (harbour, steaming, and
ommended that the flexible couplings are dynamic positioning) and where, in some
When a clutch is positioned in the made with a torsional limit device, so that of these load conditions, the engine
shaftline, an external thrust bearing is re- in the event of breakage of the flexible el- speed is not kept at a constant level.
quired, so that both forward and aftward ements, steel parts will transmit the
thrust are transmitted to the tanktop, aft torque until the safety system has shut Alternatively, one diesel generator can be
of the clutch. The clutch and the thrust down the engine. used to supply the electric power for the
bearing are normally made as a unit. general electricity consumption when the
In harbour, the speed, and thus the effi- engine speed is reduced.
When a clutch is to be placed in the ciency, of the cargo pumps can be con-
shaftline, a study of the engine accelera- trolled by varying the speed of the engine In all cases, transformers are needed to
tion behaviour must be performed, illus- that drives the shaft generator and thus provide voltage regulation between the
trating the outcome of an immediate loss varying the electrical frequency (in a pro- alternators and the ship service switch-
of electrical load on the shaft generator pulsion plant with two main engines, the board.
with the propeller disconnected. other engine is at standstill and accessible
for overhaul).
Such a study normally results in the set-
ting of minimum requirements for the in-
Fig. 20: An 8,600 kW PTO arrangement for a shuttle tanker, being tested at the Renk works
25
11.2 Auxiliary propulsion system The Alpha Clutcher is operated by hy- The requirements of some classification
draulic oil pressure which is supplied by societies differ depending on whether the
From time to time, an auxiliary propulsion the power pack used to control the CP- auxiliary propulsion system is to be used
system (Power Take Off / Power Take In) propeller. as a take home system (in the event of
is requested, especially in connection failure of the main engine at sea) or as an
with projects involving gas and chemical A thrust bearing, which transfers the aux- alternative propulsion system (take away
tankers with main engines in the range of iliary propulsion propeller thrust to the en- from quay or alternative propulsion at low
S35-S42MC and equipped with a CP- gine thrust bearing when the clutch is dis- vessel speed).
propeller. engaged, is built into the Alpha Clutcher.
When the clutch is engaged, the thrust is The auxiliary propulsion system offered by
The auxiliary propulsion system must be transferred statically to the engine thrust MAN B&W Diesel fulfils the requirements
capable of driving the CP-propeller by us- bearing through the thrust bearing built of both alternatives, provided that suffi-
ing the shaft generator as an electric mo- into the clutch. cient electrical power for auxiliary propul-
tor while the main engine is stopped and sion of the vessel can be produced by
disengaged. The electric power is pro- To obtain high propeller efficiency in the the gensets.
duced by a number of gensets. auxiliary propulsion mode, and thus also
to minimise the auxiliary power required, The system can quickly establish auxiliary
MAN B&W Diesel can offer a solution a two-speed tunnel gear, which provides propulsion from the engine control room
where the CP-propeller is driven by the lower propeller speed in the auxiliary pro- and/or bridge, even with unmanned en-
alternator via a two-speed tunnel gear pulsion mode, is used. gine room.
box. The main engine is disengaged by a
clutch (Alpha Clutcher) made as an inte- The two-speed tunnel gear box is made Re-establishing of normal operation re-
gral part of the shafting. The clutch is in- with a friction clutch which allows the quires attendance in the engine room
stalled between the tunnel gear box propeller to be clutched in at full alterna- and can be done within a few minutes.
and the main engine, and conical bolts tor/motor speed where the full torque is
are used to connect and disconnect available. The alternator/motor is started
the main engine and the shafting. See in the de-clutched condition with a start
Figure 21. transformer.
Oil distribution
ring
26
12. Summary purposes. This may be because, in re- On the other hand, when surplus capac-
cent years, gensets have improved their ity is available from the main engine, a
A wide range of shaft generators are cost effectiveness thanks to low prices, shaft generator is still a viable solution.
available for installation in combination operation on heavy fuel oil, improved reli-
with the two-stroke engines in MAN ability and prolonged mean time between References covering the supply of gear
B&W Diesel’s comprehensive engine overhauls. based PTO systems from three major
programme. makers are listed below.
27