Вы находитесь на странице: 1из 20

GAS ABSORPTION

PRINCIPLES
ABSORPTION COLUMN MODELS
TRAY-TYPE PLATE COLUMNS LIQUID FLOW
COUNTERCURRENT
CONTACTING OF GAS AND
PERFORATED
LIQUID TRAY
CONTACTING OCCURS IN OVERFLOW WEIR
LIQUID ON TRAYS
 LIQUID FLOWS PARALLEL TO THE
TRAY
 GAS FLOWS PERPENDICULAR TO
THE TRAY
GENERAL CONFIGURATION
TRAY DESIGNS

SIEVE TRAY
BUBBLE CAPS
http://www.koch-
VALVE TRAYS glitsch.com/koch/products/flexitray_trays.asp

http://www.jaeger.com/internals- http://www.rauschertus.com/process_technologies/b
HDbubblecaptrays.htm ubblecaptrays.html
PACKED COLUMN DESIGNS
COUNTERCURRENT GAS AND LIQUID
CONTACTING LIQUID/GAS INTERFACE ON
PACKING
LIQUID FLOWS OVER THE SURFACE OF
THE PACKING WITH A GENERAL
DOWNWARD DIRECTION
GAS FLOWS THROUGH INTERSTICES IN
THE PACKING WITH A GENERAL UPWARD
DIRECTION
PACKING TYPES
RANDOM
STRUCTURED

http://dtirp.dtra.mil/products/CWC/132p-12.jpg
RANDOM PACKING

INSTALLED IN SECTIONS
LIQUID IN
DISTRIBUTION PLATE IS
BETWEEN SECTIONS DISTRIBUTION
PLATE GAS OUT

RELATIVE FLOWS DETERMINE PACKED


SECTION
HYDRDYNAMICS
LIMITING CASES
FLOODING
WEEPING
RANDOM PACKING DESIGNS

SHAPES
RINGS
SADDLES
OTHERS
MATERIALS
METAL
CERAMIC
PLASTIC

http://www.koch-glitsch.com/koch/products/plastic_random_packing.asp
RANDOM PACKING DESIGNATIONS

NOMINAL DIAMETERS
VOID FRACTION
http://www.wisconsinstamping.com/images/raschig.jpg
BULK WEIGHT https://fscimage.fishersci.com/ecat/F_Num
bers/F70000_F79999/F73000_F73999/F73
800_F73899/F738-01~wn.jpg

http://www.koch-glitsch.com/koch/products/flexiring.asp
STRUCTURED PACKING
PACKING IS MADE IN SECTIONS AND FILLS
ENTIRE COLUMN DIAMETER

http://www.sulzerchemtech.com/DesktopDefault.aspx/tabid-232/
DESIGNS FOR TRAY COLUMNS
SET UP McCABE – THIELE DIAGRAM WITH
OPERATING LINE AND EQUILIBRIUM LINE
DILUTE SYSTEMS

WHEN OPERATING AND EQUILIBRIUM LINES


HAVE CONSTANT SLOPES – KREMSER
EQUATIONS APPLY
 y1  mx2  
ln  (1  1 A)  1 A
  y2  mx2  
N (10.6  7)
ln A
 x2  y1 m  
ln  (1  A)  A
  x1  y1 m  
N (10.6  8)
ln(1 A)
NON-LINEAR SYSTEMS

OPERATING LINE BASED ON INERT FLOWS


EQUATION (10.6-4)  x2   y1   x1   y2 
L'    V '    L'    V '  
 1  x2   1  y1   1  x1   1  y2 
NORMALLY TIED TO ONE SET OF TERMINAL
CONDITIONS
GRAPHICAL FORM OF SOLUTION (McCABE-
THIELE DIAGRAM) PLOTS BOTH LINES
NUMBER OF EQUILIBRIUM STAGES

BASED ON INTEGER
STEPS BETWEEN
OPERATING LINE AND
EQUILIBRIUM LINE.
ABSORPTION,
OPERATING LINE LIES
ABOVE THE EQULIBRIUM
LINE
STRIPPING, OPERATING
LINE LIES BELOW THE
EQUILIBRIUM LINE
LIMITING CASES
(L/V)min
OPERATING LINE WITH TERMINATION ON EQUILIBRIUM
LINE
REQUIRES INFINITE STAGES
(L/V)min MAY OCCUR AT FIRST INTERSECTION OF
STRAIGHT LINE FROM TERMINAL POINT WITH
EQUILIBRIUM LINE
(L/V)des = (L/V)min(MULTIPLE)
DESIGN TERMINAL POINT IS BASED ON MASS BALANCE
FINITE NUMBER OF EQUILIBRIUM STAGES
FOR LESS THAN EQUILIBRIUM STAGES, USE MUPHREE
EFFICIENCY (11.5-2) yn  yn 1
M 
y *n  yn 1
PACKING PRESSURE DROP

CONTACTING EFFICIENCY IN ABSORBER


SURFACE AREA/UNIT VOLUME
HYDRODYNAMICS
SURFACE AREA
TABLE 10.6-1 FOR A RANGE OF PACKING
TABLE 14.7b IN PERRY’S
LIMITING CONDITIONS
LOW FLUXES – CHANNELING OR WEEPING
HIGH FLUXES – FLOODING
PRESSURE DROP CORRELATIONS

EMPIRICAL DATA
PERRY’S FIG. 14-48
THRU 14-59
FIG. 10-6-5 &10.6-6
BASIS IS DRY
FLOW
FLOODING LIMIT
FP TABLE 10.6-1
 in.w.c. 
Pflood    0.115 FP0.7 (10.6  1)
 ft Packing  http://www.cheresources.com/acidpacktowerfig3print.shtml
DESIGN FLUXES
DIAMETER OF COLUMN IS BASED ON FLUX CALCULATION
NORMALLY CONTROLLED BY VAPOR FLUX
RECOMMENDED DESIGN VALUES RANGE FROM 65% - 80%
OF FLOODING
EXPERIMENTAL DATA
BEST METHOD
EDGE EFFECTS FOR SMALL TEST COLUMNS
MIST ELIMINATOR
INCLUDED IN MOST DESIGNS
RECOVERS ENTRAINED DROPLETS ABOVE PACKING
MIST ELIMINATORS
TYPES INCLUDE
VANE
CYCLONIC
MESH http://www.acsseparations.com/mmstr.htm

ELECTROSTATIC

http://www.bionomicind.com/images/series9000.jpg

http://www.amistco.com/PRODUCTS/ELIMINATORS/ms
http://www.knitmesh.com/business/separatio
h_vne.html n/mist_eliminators/vanemisteliminators.html
http://img.alibaba.com/photo/266357355/Electrostatic_Oil_Mist_Eliminator_for_Kitchen_Exhaust_Ventilation_S
MIST ELIMINATOR RANGES
TYPE
DEPENDS ON
PARTICLE
DIAMETER

http://www.knitmesh.com/bu
siness/separation/mist_elimi
nators/separationmechanis
ms.html
CYLCONIC MIST ELIMINATORS
DESIGN BASES
PERRY’S 7th, P. 26-36
SECTION 14.4F

http://www.epa.gov/eogapti1/m
odule6/matter/control/control.ht
http://www.koch-ottoyork.com/downloads/ProductCatalog.pdf m#esptypes
ELECTROSTATIC PRECIPITATORS

ESP CAN REMOVE


AEROSOLS OR PARTICULATE
FROM A GAS STREAM

http://www.epa.gov/eogapti1/module6/
matter/control/control.htm#precipit

CAN REMOVE SUBMICRON


PARTICLES

Вам также может понравиться