Вы находитесь на странице: 1из 2

STANDARD ELECTRICAL SYMBOLS

FOR SCHEMATIC CONTROL DIAGRAMS

ITEMS

--
SYMBOL IN WORDS OPERATION FUNCTIONS

~
RELAY COIL

RELAY ~I- R1
NORMALY OPEN CONTACT CLOSES INSTANTANEOUSLY WHEN COIL IS ENERGIZED

~
R1
NORMALY CLOSED CONTACT OPENS INSTANTANEOUSLY WHEN COIL IS ENERGIZED

~
ENERGIZED DE-ENERGIZED
RELAY COIL

~
i

~
i
TDI r DELAY!
NORMALY OPEN CLOSE
~ OPEN

~
w TIMED CLOSED
i;
z NORMALLY CLOSED CLOSE ~ ~
TIME DELAY RELAY

~
0 TIMED OPEN OPEN i i
I
i

~
NORMALLY OPEN
TIMED OPEN
CLOSE
OPEN J ¡: T

~
w i
0
iL
"-
0
NORMALLY CLOSED
TIMED CLOSED
CLOSE
OPEN l~i ¡: T

Î
LIMIT SWITCH

FLOW SWITCH ~
~ 0-100

0-200
NORMALLY OPEN

NORMALY OPEN
CLOSES WHEN ACTUATED BY MECHANICAL FORCE

CLOSES WHEN WATER STARTS TO FLOW

--
NORMALY CLOSED OPENS WHEN WATER STARTS TO FLOW

NORMAY OPEN CLOSES AS THE PRESSURE INCREASES TO A SPECIFIC


PRESSURE SWITCH
-o NORMAY CLOSED
RANGE (IN PSI)
OPENS AS THE PRESSURE INCREASES TO A SPECIFIC
RAGE (IN PSI)

PUMP UP OPERATOR CLOSES AS THE WATER LEVER FALLS TO A SPECIFIC DEPTH


-- T 0-
FLOAT SWITCH
-- 0-
0 PUMP DOWN OPERATOR OPENS AS THE WATER LEVR FALS TO A SPECIFIC DEPT

--
PUSH BUTON SWITCH

--
---L0- NORMAY OPEN
NORMAY CLOSED
PUSH TO CLOSE, RELESE TO OPEN
PUSH TO OPEN, RELESE TO CLOSE

Jl

AUO I ~
SOLENOID VALVE CONTROL

SELECTOR SWITCH

TIME METR
0
o-
FOR FLOOR PLANS

LIGHTING FIXTRE, CEILING MOUNTED

LIGHTING FIXTURE, WALL MOUNTD AT HEIGHT SHOWN

D FLOODLIGHT FIXTRE, WALL MOUNTED


I
CONNECTED WIRES

--pr-
'"
I
NON-CONNECTED WIRES

OUT-GOING TERMINAL

PROBE
Q
D- FLOODLIGHT FIXTURE MOUNTD ON POLE TOP

co FLOURESCENT LIGHTING FIXTRE


LIGHTING FIXTURE DESIGNATIONS (LOCATED ADJACENT TO
FIXTRES). "A" INDICATES FIXTRE TYPE. (SEE FIXTURE

~pl
-N.... SCHEDULE FOR ALL TYPES). "2140" = TWO 40 WATTS
LAPS

OL
c¡ DUPLEX OUTET, + 16"
STARTER COIL
-( Jr.ur = DUPLEX OUTET WITH BUILT-IN GROUND FAULT CIRCUIT
INTERRUPTER, + 16"

LOS ANGELES COUNTY WATERW.ORKS DISTRICTS


STANDARD PLAN
DEPARTMENT OF PUBLIC WORKS
APPROVED
/"
r- ~/I'/ ~¿/ APRIL 200
W-43
ASSISTAN ~EPU1 DI~ECTOR .. DATE SHEET 1 OF 2
STANDARD ELECTRICAL SYMBOLS (CONTINUED)

FOR FLOOR PLANS (CONTINUED) FOR HYDRAULIC FLOW SCHEMATIC DIAGRAMS (CONT.)

a SPECIAL OUTLET AS INDICATED ON PLA

Q) CD JUNCTION BOX, CEILING I WALL MOUNTED

cr THERMOSTAT, + 3'-0"
~ ~ PROBE

L- SURFACE TANK
(= HYDROPNEUMATIC TANK
-T- TELEPHONE CONDUIT SYSTEM, 3/4" CONDUIT UNLESS
OTHERWISE NOTED II WATER SYSTEM GRID
~ TELEPHONE OUTLET, + 4'-6" ON WALL

c: DISCONNECT SWITCH, SIZE AND POLE AS REQUIRED

s. TOGGLE SWITCH, + 4'-0"

5:. 3-WAY SWITCH, + 4'-0"

~ DISTRIBUTION SWITCH BOARD, SEE DETAIL ON PLA

_ ELECTRICAL LIGHTING PANEL, + 6'-6" TO TOP, SEE


SCHEDULE
FOR SINGLE LINE POWER DIAGRAMS
i: ELECTRICAL EQUIPMENT ENCLOSURE AS INDICATED,
SEE DETAIL
SCE ~ WETHER-HEA FOR OVERHEA POWER SERVICE.
- CONDUIT CONCEAED IN CEILING OR WALL ::: INDICATE POWER COMPANY AND SYSTEM TYE
AND FREQUENCY)

t-
60HZ (VOLTAGE, PHASE, WIRE

- CONDUIT IN OR BELOW FLOOR


KILG-WATT-HOUR METR PER POWER COMPANY'S
- - - - - CONDUIT EXPOSED REQUIREMENT

-. HOME RUN TO PANEL, LETTR DENOTES PANEL, CIRCUIT BREAER. SHOW AMPERE RATING, NUMBER
100A.T
NUMBER DENOTES CIRCUIT (l2DA.F OF POLES, AND FRAE SIZE IF LARGER FRAME IS
Y3P. NEEDED IN THE FUTURE
- CONDUIT BEND UP OR DOWN
MAGNETIC MOTOR STARTER, NEMA SIZE AS INDICATED
$2
FOR HYDRAULIC FLOW SCHEMATIC DIAGRAS
DISCONNECT SWITCH, SHOW SIZE AND POLES
-- GATE VALVE
+~
.J ~A TRANSFORMER, SHOW KVA RATING, PRIMAY AND
-- CHECK VALVE SECONDARY VOLTAGE
;;2l40
-- HYDRAULICALLY OPERATED VALVE (DIAPHRAGM)

-- CONTOL WIRES
LJ BOOSTER PUMP "A"

0- WELL PUMP (NO. 15)


$
è
fIT7A
BO 'A"

rt
SOLID NEUTR BLOCK

PUMP OR MOTOR, SHOW HORSEPOWER


PULL LOAD AMPERES
AND

PANEL DESIGNATION, LOAD CENTR OR ELECTRICAL


--'A' EQUIPMENT AS INDICATED. SHOW CONNECTED LOAD
~ CHLORINATOR 22 5K AND PROVIDE SCHEDULE OR DETAIL
._ PU DO
--- PlUP
-0 FLOAT SWITCH

f: FLOAT VALVE
PS
ø PRESSURE GAGE
GENERAL NOTE:
¡ PRESSURE SWITCH
SEE STANDARD PLA W-3 FOR OTHER SYMBOLS

1:05' ANGELES COUNTY WATERWORKS DlSTRICTS

APPROVED ~~~ ~L~


_ A
DEPARTMENT OF PUBLIC WORKS
ASSISTANtøPuWDIRECTOR ~
APRIL 2004
DATE
STANDARD PLAN

W-43
SHEET 2 OF 2

Вам также может понравиться