NEW 5 4/5 Digits Hand Held

DIGITAL MULTIMETER
SUR

50000/500,000 counts GE
P
8kV ROTE
(1.2 C
/50m TION
s)

KM859CF, KM857 GENERAL SPECIFICATIONS


DISPLAY : 4-4/5 digits 50,000 counts. TRANSIENT PROTECTION : 8kV (1.2/50ms
Selectable stable mode 5-4/5 digits surge)
500,000 counts for DC Voltage, & 6 digits STANDARD ACCESSORIES : Test leads (pair),
999,999 counts for Hz. holster, battery installed, user’s manual,
POLARITY : Automatic banana plug K type Thermocouple x1
UPDATE RATE : (KM859CF only)
4-4/5digits fast mode : 5 per second OPTIONAL ACCESSORIES : PC interface Kit
nominal; (RS232 optical adapter cable + RS232
5-4/5 digits stable mode : 1.25 per second Software floppies) banana pins to
nominal; 42 Segments Bar K-type socket plug adapter
Graph : 60 per second max
SPECIAL FEATURES : Record MAX, MIN,
LOW BATTERY : Below approx. 7V MAX-MIN reading. Crest (Instantaneous
OPERATING TEMPERATURE : Peak hold) MAX, MIN, MAX-MIN reading.
0°C to 45°C Relative zero mode. 500,000 counts high
RELATIVE HUMIDITY : Maximum relative resolution stable reading mode. Backlighted
humidity 80% for temperature upto 30°C display dBm readings.T1-T2 differential
decreasing linearly to 50% relative humidity temperature readings (KM859CF only).
at 45°C %4-20mA loop current readings. High noise
rejection filtered Line Level Frequency mode.
STORAGE TEMPERATURE : -20°C to
Data Hold. Audible & Visible input warning.
60°C, 80% R.H. (With battery removed)
SENSING : AC, AC+DC True RMS
POWER SUPPLY : Single alkaline 9V
battery.
POWER CONSUMPTION : 5 mA typical
APO TIMING : Idle for 4.5 minutes
APO CONSUMPTION : 20mA
DIMENSION : L186mm X W87mm
X H35.5mm; L198mm X W97mm
X H55mm with holster
WEIGHT : 390 gm; 500 gm with holster
Approx.
SAFETY : The Meters meet the
requirements for double insulation to
IEC61010-1 (1995), EN61010-1 (1995),
UL3111-1(6.1994), CSA C22.2
NO. 1010-1-92 Installation CAT III
1000 V AC and DC, CAT IV 600V
E.M.C. : Meets EN55022(1994/A1;
1995/Class B) and EN50082-1(1992)
OVERLOAD PROTECTION :
mA & mA : 0.63A/500V, IR 100kA, F fuse
for KM857;1A/600V, IR
100kA, F fuse for KM859CF
A : 12.5A500V, IR 10kA, F fuse
for KM857;15A/1kV, IR 10kA
F fuse for KM859Cf
V : 1050Vrms, 1450Vpeak;
mV : W & Others : 600VDC/VAC
rms for KM857 (1050Vrms,
1450Vpeak for KM859CF

Digital Multimeter best in india Kusam Meco kusum meco railways multimeters indian mutimeter KM multimeters instruments meter kolkata calcutta Indian multimeter 859CF 6 digit multimeter measure at par fluke cat iv multimeter
A1
ELECTRICAL SPECIFICATIONS
ACCURACY IS ± (%Reading digits + number of digits) or otherwise specified, at 23°C ± 5°C & less than
75% relative humidity. True RMS voltage & current accuracies are specified from 5 % to 100% of range
or otherwise specified, Maximum Crest Factor < 5:1 at full scale & <10:1 at half scale, and with frequency
component within the specified frequency bandwidth for non-sinusoidal waveforms.

DC VOLTAGE CAPACITANCE AC & AC + DC VOLTAGE


Range Accuracy *
Range KM859CF KM 857 Range KM859CF KM857
50.00nF 0.8% +3d
Accuracy Accuracy*
500.0nF 0.8% +3d
500.00mV,5.0000V, 5.000mF 1.0% +3d 20Hz -- 45Hz
0.02% rdg + 2 dgts 0.03% rdg + 2 dgts 500.00mV,
50.000V 50.00mF 2.0% + 3d Unspec’d
1.5% rdg + 40 dgts
500.0mF 3.5% + 5d
5.0000V, 50.000V
500.00V 0.04% rdg + 2 dgts 0.05% rdg + 2 dgts
1000.0V 0.05% rdg + 2 dgts 0.1% rdg + 2 dgts 9999mF 5.0% +5d 500.00V, 1000.0V Unspec’d
NMRR : > 60dB @ 50/60Hz *Accuracies with film capacitor 45Hz -- 300Hz
CMRR : > 120dB @ DC, 50/60Hz, Rs = 1kW or better
500.00mV, 0.3% rdg + 20 dgts
Input Impedance : 10MW, 30pF nominal (80pF nominal for 500mV ranges)
Hz Line Level Frequency 5.0000V, 50.000V 0.8% rdg + 20 dgts 0.8% rdg + 60 dgts
Range Accuracy 500.00V, 1000.0V 0.4% rdg + 40 dgts
%DIODE TESTER 5.0000Hz--
0.002%+4d 300Hz -- 5kHz 300Hz -- 1kHz
Range Accuracy Test Current Open Circuit 200.000kHz
Sensitivities (Sine RMS):
500.00mV, 0.3% rdg + 10 dgts 0.8% rdg + 40 dgts
(Typical) Voltage 5.0000V, 50.000V
0.1V min @500mV range
0.4% rdg + 40 dgts 2.0% rdg + 60 dgts
5.0000V 1 %+1d 0.8mA < 3.5 VDC 1V min @5V range 500.00V
10V min @ 50V range
0.8% rdg + 40 dgts
dBm : 100V min @500V range 1000.0V 1.0% rdg + 40 dgts
At 600W, -11.76dBm to 54.25dBm, 900V min @1000V range (300Hz--1kHz)
Accuracy : ± 0.25dB + 2d (@40Hz -- 20kHz) OHMS 5kHz -- 20kHz 1kHz -- 20kHz
Input Impedance : 10MW, 30pF nominal Selectable Range KM859CF KM857 500.00mV, 0.5% rdg + 20 dgts 1dB* *
reference impedance values of 4, 8, 16, 32, 50, Accuracy
75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 5.0000V, 50.000V 0.8% rdg + 20 dgts 2dB* *
500.00 W 0.07% + 10d
600, 800, 900, 1000, 1200W 5.0000 kW 500.00V 0.5% rdg + 20 dgts 3dB* *
50.000 kW 0.1%+6d
0.07% +2d
Crest mode (Instantaneous Peak Hold) : 500.00 kW 1000.0V Unspec’d Unspec’d
Accuracy : Specified accuracy ± 100 digits for 5.0000 MW 0.2% +6d 0.4% +6d
changes > 0.8ms in duration 50.000 MW 2.0% +6d 2.0% +6d
20kHz -- 100kHz
Open Circuit Voltage : <1.3VDC 500.00mV, 2.0% rdg + 40 dgts
(<3VDC for 500W range) 5.0000V, 50.000V 4.0% rdg + 40 dgts* *
AC & AC + DC CURRENT Unspec’d
500.00V
Range KM859CF KM857 Burden Unspec’d
Voltage 1000.0V
Accuracy *From 5% to 10% of range : accuracy % of reading (or in dB) + 80d
* *From 5% to 10% of range : accuracy % of reading (or in dB) + 180d
50Hz -- 60Hz * * From 10% to 15% of range : accuracy % of reading (or in dB) + 100d
500.00mA 0.15mV/mA CMRR : > 90dB @ DC to 60Hz, Rs = 1kW
5000.0mA 0.15mV/mA Input Impedance : 10MW, 30pF nominal (80pF nominal for 500mV range)
50.000mA 3.3mV/mA Residual reading less than 50 digits with test leads shorted.
0.5% + 50d 1.0% + 40d
500.00mA 3.3mV/mA
5.0000A 0.03V/A
T1-T2 DUAL TEMPERATURE (KM859CF only)
10.000A* 0.03V/A Range Accuracy
40Hz -- 1kHz -50.0 °C TO 1000.0°C 0.3% + 1°C
-58.0 °F TO 1832.0°F 0.3% + 2°F
500.00mA 0.15mV/mA
Thermocouple range & accuracy not included
5000.0mA 0.15mV/mA
50.000mA 0.7% + 50d 1.0% + 40d 3.3mV/mA DC CURRENT
500.00mA 3.3mV/mA
Range Accuracy Burden Voltage
5.0000A 0.03V/A
500.00mA 0.15% rdg + 20 dgts 0.15mV/mA
10.000A* 0.03V/A
5000.0mA 0.1% rdg + 20 dgts 0.15mV/mA
1kHz -- 10kHz
50.000mA 0.15% rdg + 10dgts 3.3mV/mA
500.00mA 0.15mV/mA
5000.0mA 500.00mA 0.1% rdg + 20 dgts 3.3mV/mA
0.15mV/mA
2.0% + 50d Unspec’d 5.0000A 0.5% rdg + 10 dgts 0.03V/A
50.000mA 3.3mV/mA
500.00mA 3.3mV/mA 10.000A* 0.5% rdg + 20 dgts 0.03V/A
5.0000A * 10A continuous, 20A for 30 second max with 5
Unspec’d Unspec’d 0.03V/A minutes cool down interval
10.000A*
*10A continuous, 20A for 30 second max with
DC Loop Current %4--20mA
5 minutes cool down interval
4mA = 0% (zero); 20mA = 100% (span)
%DUTY CYCLE Resolution : 0.01% Accuracy : ± 25d
Hz LOGIC LEVEL FREQUENCY
Range Accuracy
Range Accuracy
0.1 % -- 99.99% 3d/kHz+2d Audible Continuty Tester
5.0000Hz--
0.002%+4d Audible threshold : between 20W and
2.00000MHz Input Frequency : 5Hz -- 500 kHz,
Sensitivities : 2.5Vp square wave 5V Logic Family 120W. Response time < 100ms

Industrial Supply Syndicate


Office : 54. Ezra Street, Kolkata - 700 001, India.
An ISO 9001:2000 company Tel. : (033) 3291 6080, 22356676 Fax : (033) 3022 2923
E-mail : info@industrialindia.com, Website : www.industrialindia.com