No. Of Ultimate Ultimate Qk Service Live Loads in kN/m² for given Spans
4mm ø Resist. Moment Shear Resist.
Wires Mu(10^6) Vu Spans (mm)
/ Rib kNm/1000mm kN/1000mm 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 7600
5 37.79 37.16 7.06 6.16 5.21 4.38 3.65 3.00 2.43 1.93 1.47 1.06 0.70 0.36 0.06 -0.22 -0.47 -0.70 -0.91 -1.10 -1.28
8 60.46 43.46 9.03 8.38 7.80 7.26 6.77 6.31 5.90 5.51 5.09 4.43 3.84 3.31 2.83 2.39 1.98 1.62 1.28 0.97 0.68
6.07 Qk Service Live Loads in kN/m² for given Spans - Based On Ultimate Resist. Moment
7.26 6.16 5.21 4.38 3.65 3.00 2.43 1.93 1.47 1.06 0.70 0.36 0.06 -0.22 -0.47 -0.70 -0.91 -1.10 -1.28
14.34 12.58 11.06 9.73 8.57 7.54 6.63 5.81 5.09 4.43 3.84 3.31 2.83 2.39 1.98 1.62 1.28 0.97 0.68
Qk Service Live Loads in kN/m² for given Spans - Based On Ultimate Shear Resist.
7.06 6.51 6.00 5.55 5.12 4.74 4.38 4.05 3.74 3.46 3.19 2.94 2.71 2.49 2.28 2.08 1.90 1.72 1.56
9.03 8.38 7.80 7.26 6.77 6.31 5.90 5.51 5.15 4.81 4.50 4.21 3.94 3.68 3.44 3.21 2.99 2.79 2.60