Вы находитесь на странице: 1из 1

Gamma Ray and Spontaneous Potential

Schlumberger

SP Correction Chart (Empirical)


SP-4m
(Metric)

200-mm hole; 86-mm tool, centered


100 1.0
di (m)
0.5
90
SP

0.
Ri

75
0.

0.
Rm

75

75
80

0.7

0.8
5
0.7

0.8
5
5

8
1.0
70

1.0
1.5

Correction factor
% ESSP

60

50 20 2.0

40 2.5
50

3.0
30
100 3.5
4.0

20 5.0
200

20 15 10 5 3 2 1
Bed thickness, h (m)
© Schlumberger

Example: SP = –80 mV in a 3-m bed Therefore, R i /R m = 10/0.5 = 20


R m = 0.5 ohm-m, and R i (invaded zone resistivity) = SP correction factor = 1.1
10 ohm-m (both at formation temperature) Corrected SP, E SSP = –80 (1.1) = –88 mV
Invasion diameter = 0.80 m