APPROVAL AUTHORITIES
ITEMS
MPW
JEBEL ALI NORTHERN HAMRIYAH (Public DMW
DUBAI FREE ZONE ABU DHABI SHARJAH SAIF EMIRATES FREE ZONE Works) (Military)
Roof Live Load 0.60 KN/M2 0.60 KN/M2 0.60 KN/M2 0.60 KN/M2 0.60 KN/M2 0.60 KN/M2 0.60 KN/M2 0.75 KN/M2 0.75 kN/m2
Wind Speed 45 m/sec 45 m/sec 45 m/sec 1.00 KN/M2 45 m/sec 45 m/sec 45 m/sec 45 m/sec 45 m/sec
Zone 2A Zone 1 Zone 1
1. Design LoadiSeismic Loads - - - - - -
UBC 1997 UBC 1997 UBC 1997
Temperature Loads - + 25oC - - - - - - + 30oC
Mezzanine Live Load 5.00 KN/M2 5.00 KN/M2 Per Spec 5.00 KN/M2 5.00 KN/M2 5.00 KN/M2 5.00 KN/M2 Per Spec Per Spec
Pattern Loading Requirement (for Purlin) Not Reqd. Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd.
Wind Load Building Code MBMA-96 MBMA-06 MBMA-96 MBMA-96 MBMA-96 MBMA-96 MBMA-96 MBMA-96 MBMA-96
Flange 6mm 6mm 6mm 6mm 6mm 5mm 6mm 6mm 8mm
2. Main Frame - Minimum Thickness
Web 6mm 6mm 4mm 4mm 6mm 4mm 4mm 6mm 6mm
3. Built-up
Endwall Rafter Flange 6mm 6mm 6mm 6mm 6mm 5mm 6mm 10mm 8mm
and Built-up Minimum Thickness
Endwall
Web 4mm 6mm 4mm 4mm 6mm 4mm 4mm 5mm 6mm
Column
Flange 6 6 6 6 6 6 6 - -
4. Minimum Thickness of Built-Up Crane Run
Web 5 6 4 4 6 4 4 - -
Flange 6 6 6 6 6 5 6 - 8
5. Minimum Thickness Built-Up Mezzanine Be
Web 6 6 4 4 6 4 4 - 6
Flange 6 6 6 6 6 5 6 - 8
6. Minimum Thickness Built-Up Mezzanine Jois
Web 4 6 4 4 6 4 4 - 6
Flange 6 6 6 6 6 5 6 - 8
7. Minimum Thickness Built-Up Canopy Rafter
Web 4 6 4 4 6 4 4 - 6
Built up Built up Built up Built up Built up Built up Built up Built up
8. Crane Beam I-Section Type Hot rolled only
Allowed Allowed Allowed Allowed Allowed Allowed Allowed Allowed
Purlins 1.5mm 1.5mm 2mm 1.5mm 1.5mm 1.5mm 1.5mm 1.5mm 2.5mm
9. Minimum Secondary Member Girts 1.5mm 1.5mm 1.5mm 1.5mm 1.5mm 1.5mm 1.5mm 1.5mm 2.5mm
Type of Fixing N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. Cleat
Per Customer Per Customer Per Customer Per Customer Per Customer Per Customer
13. Maximum Bay Spacing (M) 8.0 9.0 8.0
Dwg Dwg Dwg Dwg Dwg Dwg
14. Anchor Bol Main Frame Side Wall Column 4 Nos. 4 Nos. (G) 4 Nos. 4 Nos. 4 Nos. 4 Nos. 4 Nos. 4 Nos. (G) 4 Nos.(G)8.8
(G-Galvani Main Frame Interior Column 4 Nos. 4 Nos. (G) 4 Nos. 4 Nos. 4 Nos. 4 Nos. 4 Nos. 4 Nos. (G) 4 Nos.(G)8.8
Endwall
Built-up/Hot Rolled 4 Nos. 4 Nos. (G) 4 Nos. 4 Nos. 4 Nos. 4 Nos. 4 Nos. 4 Nos. (G) 4 Nos.(G)8.8
Columns
Minimum Diameter Reqd. 12mm 16mm 12mm 12mm 12mm 12mm 12mm 12mm 12mm
Below 4.50 M Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd.
15. Sag Rod Re No. of Rows 1 Row above
Required for 4.50M - 7.60M Per Design 1 Row Per Design 1 Row 1 Row Per Design Per Design Per Design
6.0 m
Bays length of
1 Row above 1 Row above 1 Row above
Above 7.60M 2 Rows 2 Rows 2 Rows 2 Rows Per Design Per Design
8.0 m 7.0 m 8.0 m
4mm thick 4mm thick
Alternative
16. Flange Stay Minimum Angle Requirements Per Design 4mm thick Per Design both sides both sides Per Design Per Design 4mm thick
Purlin
Alt. Purlin Alt. Purlin
Required both
17. Washer Requirement for Structural Bolts & Sag Rods Not Reqd. Required Not Reqd. Not Reqd. Not Reqd. Not Reqd. Not Reqd. Required
sides
20. Cladding Profile (Any special) N.A. N.A. N.A. N.A. N.A. N.A. N.A. 45/150 TR45/150
Aluminum in
No Restriction No Restriction No Restriction No Restriction No Restriction No Restriction No Restriction No Restriction general but
21. Cladding Type (Any special) not limited to.
Alum Shallow
Alum Foil Alum Foil Alum Foil Alum Foil Alum Foil Alum Foil Alum Foil Alum Foil rib in general,
Accepted Accepted Accepted Accepted Accepted Accepted Accepted Accepted but not limited
23. Liner for Sandwich Panel to.