Digest
Residential Building Data Center Industry Energy and Infrastructure
SM
Going places?
Wherever you go, well be there managing the energy.
Schneider Electric is the global specialist in energy management. We offer integrated solutions making energy safer, more reliable, more efficient, more productive and green. Developing technologies, processes and solutions that are so simple, efficient and renewable, you forget theyre even there.
2009 Schneider Electric. All rights reserved.
Visit us at
www.schneider-electric.us
SM
e-Catalog
Need help choosing the right product? Try our Product Selector. Find and print accurate, up-to-date product data at the part number level for submittals and proposals. To get started, look for the following link on our internet home page.
Product Index
Section Listing 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Load Centers Metering Equipment Safety Switches Power Monitoring and Control Lighting Control and Integrated Home Systems Surge Protective Devices Miniature and Molded Case Circuit Breakers Operator Mechanisms and Disconnect Switches Panelboards Integrated Power and Control Solutions (IPaCS) Equipment Switchboards and Switchgear Busway Wire Management Transformers Medical Products NEMA Contactors and Starters Motor Control Centers IEC Contactors and Starters Push Buttons and Operator Interface Electronic Sensors and Machine Cabling Limit Switches Pressure, Vacuum, and Float Switches Relays and Timers Terminal Blocks Machine Safeguarding Products AC Drives and Soft Starts Automation Products Product Locator Index
of Exce a rs l
nce le
75
Customer Services
Customer Literature Center
To obtain literature for product or application needs, contact the Square D Customer Literature Center. When requesting additional technical catalog information, refer to the catalog section listed at the bottom of the Digest pages. To quickly find and download technical literature and marketing collateral, go to ecatalog.squared.com/techlib.
Energy Efficiency
Offer a wide range of energy efficiency solutions, services and products for the building, industry and infrastructure, data center and residential markets. Schneider Electric leverages its complete portfolio to provide the right mix of solutions for its target vertical markets, each of which have diverse energy profiles and priorities. Our energy efficiency solutions include power metering and energy management systems, lighting and lighting controls, motor controls and automation solutions, building management systems, power factor correction, and energy consulting and services. Implementation of these solutions can enable up to 30% energy savings in many cases. This allows customers to differentiate themselves in the marketplace, enhance profitability and reduce their strain on the environment.
Offers the industrys most comprehensive approach to meet NFPA 70E, Part 2 requirements.
Engineering analysis Training programs New equipment Equipment upgrades Emergency services Available 24 hours a day, seven days a week Service for ALL manufacturers equipment
1-888-SquareD (1-888-778-2733)
www. schneider-electric.us
SM
Digest
33% faster on average than a typical commercial project your mind at ease
The competency center manages communication and coordination among all parties including electrical contractors, consulting engineers and manufacturers of generators (UPS and paralleling switchgear).
www.schneider-electric.us
Contact us
Contact your local Square D Schneider Electric field sales representative, or if you dont know your local representative, call the Customer Information Center at 1-888-Square D (1-888-778-2733).
Sign up now
Sign up to receive the free newsletter at www.drawingwaternews.com
Section 3 Section 4 Section 4 Section 11 Section 11 Sections 16 and 17 Section 17 Sections 18 and 26 Section 22 Section 26 Section 27 Section 27
Digest
Square D Services
24/7
Engineered solutions designed to increase safety, lower lifecycle cost and maximize power system reliability
When it comes to electrical distribution equipment, Square D Services delivers a complete range of solutions to keep you up and running. Startup and commissioning, maintenance, testing, reconditioning... you name it. Our network of trained technicians and engineers knows how to get the most from your electrical equipment even if we didnt manufacture it.
Services solutions
Low- and medium-voltage equipment upgrade solutions
Infrastructure upgrades can be costly in terms of both downtime and new equipment replacement. However, increasing equipment reliability does not necessarily mean incurring the cost of installing entirely new equipment.
Low-voltage Masterpact direct replacement/retrofill circuit breakers Medium-voltage powersub substation circuit breakers Medium-voltage direct-replacement/retrofill circuit breakers Electronic circuit breaker remote racking systems H.VIR Comet infrared inspection window Wireless temperature monitoring Engineering services
Electrical assessments and studies to maximize the performance of your electrical system.
www.schneider-electric.us
Electrical South
The leader in industrial electronic repair, Electrical South repairs over 120,000 different products from over 2,500 manufacturers.
Turnkey solutions
Complete turnkey solutions for low- and medium-voltage electrical distribution equipment.
ECP Services
ECP has over 50 years of experience providing a range of high-quality services for electrical systems. Today, ECP is a fully-integrated member of the Square D Services family, offering engineered solutions designed to increase safety, lower lifecycle cost and maximize power system reliability. Our Construction Services division provides the services required for small jobs and turnkey design, and builds contracts from 15 kV to 765 kV. Services include:
Customer training
Square D Services offers a variety of courses on maintaining electrical distribution equipment, arc flash, NFPA 70E: electrical safety, PLCs, drives, HMIs, communications, welding and servos, as well as power management. Please call 1-866-507-0894 or visit www.us.schneiderelectric.com/training
Turnkey substations and packages Cathodic protection Pole line construction Engineering designs and studies Relay and control houses Emergency generators Cable pulling
www.schneider-electric.us
Digest
Emergency field services Network services Priority support Repair and exchange Product and technology migration Customer training
Our universal industrial electronics repair service provides high-quality, fast-turnaround, single-source repair of industrial products from ALL major manufacturers, so you can simplify your maintenance operations and improve efficiency while holding down costs.
Customer solutions
Whether your needs are for a single site or global deployment, we can provide you with a customized solution and full support. From high-volume OEM panels to custom-engineered automation and drive systems, your success is assured when youre backed by the expertise and resources of Schneider Electric. Our solutions offerings are continuously expanding and include:
Engineered-to-order drive systems Engineered crane control systems Engineered water wastewater control systems Resistance weld control packages Stamping press control systems Power distribution panels Custom-engineered control panels Electrical quality detection systems for microelectronics
Our engineered drives solutions combine industry know-how and the product expertise that only the manufacturer of Altivar variable frequency drives can provide. Our world-class solutions are designed with reliability, cost-savings and safety in mind, and are supported by Schneider Electric offices worldwide.
www.schneider-electric.us
Features
Smaller total area used, with 3 in. (76 mm) clearance from ventilated
openings instead of 6 in. (152 mm), reducing the distance from the wall to the front of the device by 3 in. (76 mm) Terminals are sized to handle lug kits that are coordinated with the family of Square D products, increasing the ease of installation when used with other Square D equipment Increased wiring compartments provide a bending radius for 250% primary cables and multiple feeds on the secondary All units have 200% neutral to allow customers to feed standard and non-linear panels Decreased weight for easier handling of units The new product is designed with copper windings at 130C rise above a 200C Insulation material. Our new line of HMT also feature the following value added features:
Local area presentation available by request Technical documents that address the harmonic impact on losses Available harmonic mitigation testing program includes customer input
of specific profiles for analysis
H2 H2
H2 H2
H2 H2 H0 H0 H2 H3 H3 H0 H3 X2 X2
H1 X2 X2
H3
H1 X2 X2
H3
H1
X0 X0 X2 X1 X1 X3 X3 X0 X1 X1
X0 X0 X2 X3 X3 X0
X1 X1
Wye Zig Zag Wye Zig X3 Zag 30 Deg 30 Deg Wye Zig Zag 30 Deg
X0 X0 X2 X3 X3 X0
www.schneider-electric.us
Digest
Provides automatic control to/from stand-by generator for ease of use Allows users to maintain essential electrical loads during outages Features an all-in-one service entrance rated panel Eliminates need for a subpanel and rewiring
10
www.schneider-electric.us
Occupancy sensors
We offer a full range of sensors for any application to maximize your energy savings.
Our distinctive Clipsal controls, complement the decor of your home or business and offer the convenience of controlling lights, raising and lowering shades, selecting source music, and even controlling the temperature all from a single keypad or remote control. For large scale and commercial systems, our proven Powerlink lighting control panels provide schedule based control of branch circuits. They can be readily incorporated into an overall building control system or demand control solution. Our lighting control systems are at work in applications large and small. From the first LEED platinum certified home to many of the nations largest buildings, youll find our solutions. Visit www.squaredlightingcontrol.com or call us at 615-287-3400 option 4 or 1-888-SQUARED
Touchscreens
Choose from the Mark II monochrome or powerful color touchscreen and take complete control of a single room or an entire building.
Neo keypad
Saturn keypad
www.schneider-electric.us
11
Digest
H-Frame
J-Frame
D-Frame
Provides unrivaled protection, by a brand you trust Lower let-through energy limits mechanical stress Reliability and serviceability limits downtime
National Electrical Code (NEC) 409/UL 508A SCCR compliant Category 0 PPE rating through 600 A
D = 25/18/14 J = 100/65/25
G = 65/35/18 L = 125/100/50
Meets domestic and international standards (UL, CSA, IEC, NOM/NMX) Worldwide service and support available
Technology
Whether you are interested in metering, power quality or harmonics, Micrologic trip units help you to manage the power in your facility.
I-Line connection Plug-in module split view
Motor Circuit Protection (MCP) delivers more reliable start-ups and a wide range of adjustments. The PowerPact MCP has settings for energy-efficient motors and simplifies NEC sizing requirements, allowing faster installations and to manage the power eliminating nuisance trips.
12
www.schneider-electric.us
Compact design
To save panel space Multi 9 breakers are available with 0.71 in.
(18 mm) per pole
Easy installation
QO breakers can be installed as plug-on or bolt-on in Square D load
centers or panel board interiors to suit unique needs QOU breakers can be DIN-, flush- or surface-mounted with simplified components for rapid modification Multi 9 can be mounted on DIN-rail or mounting bases for specific requirements
System flexibility
Different trip curves (B-, C-, D-curve) available in Multi 9 to meet
sensitive, as well as high in-rush current requirements
World-wide availability
Meets global standards (UL 489, UL 1077, CSA, CCC, IEC, Nom/ANCE)
and CE marked to increase overall revenue
www.schneider-electric.us
13
Digest
PowerLogic Systems
A key component of Schneider Electrics smart energy efficiency offering, the Square D PowerLogic system offers results, expert engineers and the most complete energy and power management portfolio available.
More efficient
Certified energy engineers who propose comprehensive energy
action plans Enterprise wide analysis and reporting of energy management and emissions Cost allocation by shift, department, product or cost center to drive accountability
More productive
Demand current reporting to understand where spare capacity exist
to avoid unnecessary capital expenditures
14
www.schneider-electric.us
www.schneider-electric.us
15
Digest
Simple Each lineup has its own Ethernet web server and connects to
your network just like a PC or printer Affordable Power monitoring data comes from the relays or circuit breakers you already specify Economical Leverage existing network infrastructure and expertise, no new wires for proprietary networks No surprises Pre-engineered, configured and tested at factory so you know exactly what youll get Easy to setup...easy to use Just set the network address and monitor power from any PC on the network using a web browser Powerful Add PowerLogic software and Schneider Electric Engineering Services for a comprehensive solution customized to meet your unique requirements Its the future web-enabled equipment will soon be as commonly specified as discrete meters in years past For additional information on Transparent Ready Equipment, the documents below can be viewed online.
Transparent Ready brochure #8000BR0301 Equipment brochure #1700BR0601 Online demo Quick Start guides
Visit www.squared.com/TRE
16
www.schneider-electric.us
Unit substations
When used with medium-voltage HVL/cc switches, Power-Style QED-6 switchboards can serve as an integral part of the low-voltage equipment in a users power unit substation.
Power-Style QED-6 catalog #2746CT0101R12/07 Power-Style QED-6 handout #2746HO0101R7/06 Masterpact NT and NW catalog #0613CT0001R4/08 Masterpact NW handout #0613HO0102 Masterpact NT handout #0613HO0203 Micrologic handout #0613HO9902R8/03
Visit www.us.squared.com
www.schneider-electric.us
17
Digest
Compact footprint NEMA, UL and IEC standards compliant One-high construction Compartmentalized design More efficient power throughput from line to load Encased, non-load break isolation switch eliminates the
need for shutters Easy installation, featuring a full height cable pulling area Optional arc resistance type 2 construction
For additional information on Motorpact medium voltage controllers, the documents below can be viewed online.
Handout #8198BR0501 Specifications for FVNR, FVR, RVAT, RVSS type starting Application guide #8198DB0101R11/05
Visit www.us.squared.com/motorpact
18
www.schneider-electric.us
Because the contractor is swapping a variable cost (labor) for a fixed cost (product), their risk on the overall project is reduced. Fewer items to receive, inventory and move around the jobsite because components are factory-installed and pre-wired into a single lineup or enclosure.
For designs with multiple locations, standardized designs can be created to provide consistency between sites. Pre-assembled construction means less time required on-site to install, reducing the overall construction cycle.
Third-party controls/components can be installed, wired and tested in IPaCS integrated equipment at the factory to assure it works like its supposed to when it gets to the jobsite. Visit www.schneider-electric.us/solutions/integrated-powerand-control-solutions
MPS
IPC2
SPQ
www.schneider-electric.us
19
Digest
Most flexible and smallest footprint available in this product class Front access to control and communications wiring Short circuit current rating up to 200 kA (@480 V) without fuses High short-time withstand rating up to 100 kA for 30 cycles minimum Number of breaker operations exceeds ANSI standards without
maintenance for Masterpact NT and NW circuit breakers Micrologic Trip Units with optional PowerLogic data communications and Transparent Ready web-enabled communications features Modular circuit breaker design for easy addition of accessories and upgrades For additional information on Power-Zone 4 low voltage switchgear, the documents below can be viewed online.
Power-Zone catalog #6037CT9901R4/05 Power-Zone 4 handout #6037HO9901R6/06 Masterpact NW handout #0613HO9901R8/03 Masterpact NT handout #0613HO0201
Visit www.us.squared.com
NQ Panelboards
You spoke...we listened
Designed with feedback from electrical contractors, new Square D 240 V NQ lighting panelboards offer a simple, yet highly flexible solution for meeting a wide range of your electrical lighting and distribution project needs. And now, the NQ is available in the new 72 and 84 circuit panelboards for areas of the country that have adopted the 2008 National Electrical Code (NEC), which eliminates the 42-circuit limit for lighting panelboards.
Thanks to extensive input from electrical contractors, we designed the NQ panelboard with the following benefits.
This means contractors will no longer have to use two-section panels when more than 42 circuits are required.
Instead of two
Digest
Optimize asset management Improve spare parts utilization Schedule and implementing
product upgrades
With teams dedicated to understanding your business needs and unique industry challenges, we give you the benefit of our hands-on, practical knowledge to:
Improve operational performance Optimize your assets and simplify the migration, upgrade and
maintenance of legacy equipment
22
www.schneider-electric.us
The System Integrator and Control Panel Builder Solutions Partner Program
How do you navigate in a competitive marketplace? You need a partner to show you the way
When you get your bearings, you realize that as a system integrator or control panel builder you need more than a road map to help your business to succeed. You need a navigator, a business partner who cares how you go from point A to point B, how successful your journey is, and how you will grow your business in a competitive marketplace. You need a partner, a solutions partner a global technology leader that can supply you with the tools and training to be successful. And, you need an organization that rewards you for your loyalty and for the business you generate. With Schneider Electrics Solutions Partner program, you have arrived at your destination for success, and discovered a valuable business opportunity a partnership that will pay dividends for you and your business!
What makes the Schneider Electric Solutions Partner program different from other customer loyalty programs?
It is an all inclusive, one program for all partner levels that is simple, concise and easy to understand. The Solutions Partner Program replaces other Schneider Electric incentive programs, including:
Top Builder Authorized Panel Builder Top Integrator Authorized System Integrator
Visit www.senamicro.com/solutionspartner
www.schneider-electric.us
23
Digest
Select the exact level of control you require without sacrificing simplicity
and performance
Streamline programming by reusing functional libraries across products Reduce implementation time and cost by utilizing commercially available
cabling, modular architectures and standard networking protocols
As the choice of a generation, the Modicon line of PLCs comes with over 40 years of proven experience built into every product. It is also supported by the industries largest distribution network and the global leader in power, control and automation solutions, making it the ideal choice for simple machines to complex automation facilities and critical applications. Visit www.us.schneider-electric.com/PLC to find the Modicon PLC thats right for your business.
Modicon Premium
Preventa Solutions
Schneider Electrics Preventa family of machine safety solutions offers the most complete line of safety products for enhancing machine performance and minimizing personnel risk. From standalone safety monitoring to integrated safety controls, our comprehensive solutions enable you to select the appropriate type of safety components to match your specific industry and application needs. Easy to select, install and operate, Preventa products are globally available through local distributors and are compliant with most domestic and international standards. Designed to work together, these devices not only protect personnel, they also enable the introduction of safety equipment into your production processes to improve productivity, minimize risk and decrease equipment downtime. Visit www.us.schneider-electric.com/safety
Modicon M238
24
www.schneider-electric.us
Multi-protocol, multi-language
Advanced panels
HMI family
Advanced process visualization Versatile user interface Trending and local data logging Smart, all-in-one,
intuitive configuration More processing power More storage capacity More connectivity
Visit www.us.schneider-electric.com/HMI
Advanced process visualization Versatile user interface Trending and local data logging Smart, all-in-one,
intuitive configuration
Upload and download HMI data using Integrated diagnostic buffer for
Modicon PLCs
www.schneider-electric.us
25
Digest
The worlds most popular range of push buttons combined with innovative interface signaling devices.
Harmony control and signaling
For over 50 years, Schneider Electric has been the leading choice for 16 mm, 22 mm and 30 mm push buttons. From the worlds most popular 22 mm push buttons and the first indicating banks to the first automotive approved 30 mm operators and a full line of pendant control stations we offer unparalleled solutions for all of your control and signaling needs.
The ultimate in power, protection and control, from motor starters to motor control centers.
TeSys GV3P manual starter protector
TeSys GV3P manual starter protector The TeSys GV3P manual starter protector can be used alone for local, manual control of a single motor, or can be wired in front of a contactor to provide a complete, remotely operated motor control circuit. The manual starter protector controls and protects motors up to 50 HP at 480 VAC. It is UL listed for group motor installation and connects directly to TeSys D IEC-style contactors to reduce control panel size.
26
www.schneider-electric.us
www.schneider-electric.us
27
Digest
Lower system operational costs Improved energy savings Worldwide service and
product support
Altivar Drives
Save energy and space with the complete line of drives
The Altivar family of drives presents the most advanced and user-friendly drive solutions in the marketplace. Using proprietary motor control algorithms to increase responsiveness, improve flexibility and accelerate performance, Altivar drives offer a wide range of product capabilities and mounting solutions to provide a variety of control options, from the simplest forms of motor speed controls to the most complex drive applications with coordinated motion and network connectivity. The Altivar line of drives provide motor protection from thermal guarding, power removal safety functions and external fault management to defenses against overheating and corrosive environments. Also available is effective harmonic mitigation without using additional panel space. Altivar speed drives
Altivar 21 mid-featured AC drives Altivar 61 full-featured AC drives S-Flex enclosed drives E-Flex enclosed drives PowerGard 18-pulse
enclosed drives
Enclosed drives
Schneider Electrics line of enclosed drives integrates our industry leading Altivar drives into packaged adjustable speed solutions to meet the most demanding commercial, industrial and municipal application requirements. Featuring integrated controls optimized with disconnect means, circuit breakers, push buttons, selector switches, control logic and communications, all protected within a Type 1, Type 12/12K or Type 3 enclosure, our packaged AC drives are ideal for HVAC, pumping, fan, industrial process and machine building applications.
Altivar 12 AC nano-drives Altivar 31 mini-drives Altivar 71 full-featured AC drives M-Flex and MCC enclosed drives Altistart 01, Altistart 48 and
enclosed 48 soft starts
Visit www.us.schneider-electric.com/drives
www.schneider-electric.us
29
Digest
Carousels Overhead conveyors Automated storage/retrieval systems Lifting equipment Accumulation Sortation Merge, divert and transfer
The advantages of using these preferred implementations go far beyond speed to market. They simplify startups, minimize troubleshooting and reduce labor costs. Making this possible are dedicated material handling experts who provide solution engineering and support to develop safety compliant control systems that are accepted worldwide. Leveraging their expertise, youll be able to develop solutions that offer:
Rapid responsiveness for fast operation Long-life and durability in harsh environments Compliance with all necessary local, federal and global
regulatory standards Global support using local resources State-of-the-art remote monitoring functionality for predictive maintenance and extended machine life Exceptional ROI Visit www.us.schneider-electric.com/materialhandling
30
www.schneider-electric.us
Your source for best-in-class technology products for your automation, control and power
Whether you are designing the industrys most advanced servo-driven packaging machines synchronizing up to 99 axes of motion control or just trying to pick the right sensor to detect the color, shape, and/or size of a bottle, Schneider Electric has the right technology for your application. Weve introduced a number of innovations that are changing the way the packaging industry designs, builds and maintains equipment. And by using Schneider Electrics bestin-class technology products for your automation, control and power functions, you can be assured of seamless communication throughout the entire machines control architecture. Our packaging solutions encompass motion, sensors, HMI, safety and the services to make it work.
This need for flexible machinery is leading packaging machinery OEMs to adopt modular hardware and software designs; embrace new technologies like servo motion and robotics; and build machinery systems that implement industry standards such as IEC 61131-3 programming, PackML and PLCopen function blocks. To meet the challenges ahead, you need more than an electrical supplier. You need a partner committed to helping you solve your most complex automation challenges while working with you to adopt the latest innovation and purpose-built technology for your unique machine designs. Schneider Electrics commitment to doing just that is why we are quickly becoming the new automation, control and power partner of choice for packaging machinery OEMs around the world. As your alternative to the status quo, we are the only source for a complete electrical solution from our world-renowned Square D circuit breakers to our full suite of ELAU packaging automation systems. Schneider Electric is helping companies like yours find their competitive advantage and differentiate their packaging solutions in a crowded and demanding marketplace. Visit www.us.schneider-electric.com/packaging
www.schneider-electric.us
31
Digest
A single-source provider
Schneider Electric is more than a supplier. Were your partner for complete electrical design, joint marketing, system testing and project management support. Our OEM Technology and Solutions Center (TASC) has teams of industry experts with the hands-on, practical experience you need to meet your customers challenges by developing innovative new solutions that leverage our best-in-class power, control and automation products. As your global electrical partner, Schneider Electric can be your singlesource provider of end-to-end manufacturing services. Were there to work with you from project inception and design through implementation and long-term support. Committed to your success, well help you gain a competitive edge over your competition that only a true partner can deliver.
Crane and hoist HVAC Infrastructure Material handling and conveying Packaging Pump Semiconductor Transportation wash And more
We do this by:
32
www.schneider-electric.us
Section 9: Panelboards
NQ Panelboards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 thru 911
Section 20: Electronic Sensors & Machine Cabling Section 6: Surge Protective Devices
10 Mode Modular Externals SPD . . . . . . . . . . . . . . . . . . . . . . . . . . . High Resistance Ground (HRG) SPD. . . . . . . . . . . . . . . . . . . . . . . . Replacement Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surgebreaker Plus Low-Voltage Only Surge Suppressor . . . . . . . Surgebreaker Plus Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 62 63 68 68 XUBL Laser Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 XUBT Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 Ultrasonic Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 thru 2011 OsiSense RFID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2012
New and Enhanced Products in Digest 175 (contd) Section 23: Relays and Timers
Square D Alternating Plug-In Class 8501 Type KA . . . . . . . . . . .2310 Zelio Current Measurement Relays RM17JC and RM35JA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2330 Zelio Voltage Measurement Relays RM17U and RM35U. . . . . . .2332 Zelio Phase Measurement Relays RM17T and RM35T . . . . . . . .2331 Zelio Level Control Relays RM35L . . . . . . . . . . . . . . . . . . . . . . . . .2333 Zelio Pump Control Relays RM35BA . . . . . . . . . . . . . . . . . . . . . . .2333 Zelio Speed Control Relays RM35S. . . . . . . . . . . . . . . . . . . . . . . .2334 Zelio Frequency Control Relays RM35HZ . . . . . . . . . . . . . . . . . . .2334 Zelio Temperature Control Relays RM35AT. . . . . . . . . . . . . . . . . .2334 Square D Phase Failure Relays Class 8430 Type MP . . . . . . . . .2335 Zelio Count Counters RC87610 . . . . . . . . . . . . . . . . . . . . . . . . . . .2336 Phaseo DC Power Supplies ABL1, ABL7, and ABL8 . . . . . . . . .2337
Table of Contents
Section 1
Load Centers
LOAD CENTERS
1-2 1-2 1-4 1-5 1-5 1-6 1-7 1-9 1-10 1-11 1-11 1-11 1-12 1-13 1-14 1-15 1-15 1-16 1-17 1-17 1-18 1-19 1-19 1-20 1-21 1-22 1-23 1-24 1-25 1-8
QO Load Centers
Indoor-1, Main Lug Indoor, 1 Main Circuit Breaker Rainproof 1, Main Lugs, Main Circuit Breaker 3, Main Lugs, Main Circuit Breaker
QO Load Center, Page 1-5
New!
Meter Mains, 100200 A All-In-Ones, 100225 A Meter Mains and All-In-Ones, 300400 A Circuit Breakers, Accessories, Hubs Dimensions
Enclosed Devices
Combination Service Entrance Devices, Page 1-19
1-1
QO Plug-On Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801
www.schneider-electric.us
Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a The Square D exclusive Qwik-Open mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 A and 20 A QO circuit breakers.
QO 1P
1
LOAD CENTERS
Table 1.1:
Amperes Rating b 10 k AIR 10 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A
Table 1.2:
Ampere Rating 1030 A 3560 A 3550 A 70110 A 60100 A
Table 1.3:
Wire Sizesb
Wire Size (AWG/kcmil) 148 Al/Cu (2) 1410 Cu 82 Al/Cu 148 Al/Cu (2) 1410 Cu 82 Al/Cu 42/0 Al/Cu 4300 Al/Cu 148 Al/Cu, (2) 14-10 Cu 82 Al/Cu 42/0 Al/Cu 4300 Al/Cu 128 Al 148 Cu 128 Al 148 Cu 124 Al 146 Cu 122 Al 142 Cu
1 Space Required QO 2P
67.00 QO240H 67.00 67.00 QO250H 67.00 QO260H 134.00 QO270H 189.00 QO280H 189.00 QO290H 189.00 QO2100H 428.00 428.00 491.00 491.00 491.00 QO200
Circuit Breaker Ampere Rating Type 1030 A QO 1030 A 1P 3570 A 1030 A 1030 A QO 3570 A 2P 80125 A 150200 A QO 3P QOB-VH QOT QO-AFI, QO-GFI or QO-EPD QO-PL 1030 A 3570 A 80125 A 110150 A 1520 A 1530 A 40, 50, 60 A 1060 A
175 A 200 A Molded Case Switch 60 A max.240 Vac Molded Case Switch 100 A max.240 Vac 22 k AIRd 15 A QO115VH e 63.00 20 A QO120VH e 63.00 25 A QO125VH 73.00 30 A QO130VH 73.00 40 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A 42 k AIRd 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A
QO2000i 200.00
QO215VHg QO220VHg QO225VHg QO230VHg QO240VHg QO250VHg QO260VHg QO270VHg QO280VHg QO290VHg QO2100VHgh QO2110VHgh QO2125VHgh QO2150VHfgk QO2175VHfgk QO2200VHfgk QOH240 i QOH245 i QOH250i QOH260i QOH270 QOH280 QOH290 QOH2100 QOH2110i QOH2125
146.00 146.00 146.00 146.00 146.00 146.00 146.00 224.00 315.00 315.00 315.00 1034.00 1034.00 1061.00 1061.00 1061.00 317.00 317.00 317.00 317.00 528.00 651.00 651.00 651.00 1389.00 1389.00
QO315VHg QO320VHg QO325VHg QO330VHg QO340VHg QO350VHg QO360VHg QO370VHg QO380VHg QO390VHg QO3100VHg
371.00 371.00 371.00 371.00 371.00 371.00 371.00 477.00 530.00 530.00 530.00
Table 1.4:
Ampere Ratingb
1P120/240 Vac 15 A and 15 A QOT1515 15 A and 20 A QOT1520 20 A and 20 A QOT2020 2P120/240 Vac Common Trip
Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles.
4 Spaces Required QO 3P
Table 1.5:
For use in Old Style Non-Class CTL QO Load Centers10 k AIR Ampere Ratingb Cat. No.d
3 Spaces Required
125 A
1P120/240 Vac1 Space Required 15 A and 15 A QO1515 73.00 15 A and 20 A QO1520 73.00 20 A and 20 A QO2020 73.00 20 A and 30 A QO2030 73.00 30 A and 20 A QO3020 73.00 Two 1P Individual Trip120/240 Vac2 Spaces Required Order Two QO1515 or QO2020 circuit breakers and handle tie QOTHT QO20303020j 134.00 Current limiting QOT tandem circuit breakers have a mounting cam as shown. Installation into a QO load center can only be made in those positions having a mounting pan rail slot. Meets Paragraph 408.15 of the NEC. UL Listed as Class CTL
65 k AIRd 15 A and 15 A 15 A QH115e 117.00 QH215 293.00 QH315d 507.00 15 A and 20 A 20 A QH120e 117.00 QH220 293.00 QH320 507.00 20 A and 20 A QH325i 507.00 20 A and 30 A 25 A QH125i 117.00 QH225i 293.00 30 A QH130 117.00 QH230 293.00 QH330 507.00 30 A and 20 A a See Digest Section 1 for load centers, and Section 9 for panelboards and interiors. QOT Tandem b 1030 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35125 A circuit breakers are suitable for use with 75oC conductors. c UL Listed 5 k AIR on corner grounded Delta systems. d UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. e UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. f Requires four spaces (1 AWG300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads. g UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, QO-AFI, and QO-PL 10 k AIR circuit breakers to permit their application at 22 kA fault level. h 100 A maximum branch mounted opposite. i Order only. Contact your local Field Office. Pan Rail Slot j Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. k Not suitable for use in 3 panels. Use only in 1 panel rated 150 A or greater. Interupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-12 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
1-2
DE2A
Discount Schedule
QO Plug-On Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801
QO-HID
HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table 1.10: QO-HID Circuit Breakers
1P 120/240 Vac Ampere Ratingc 10 k AIR 1 Space Required 2P Common Trip 120/240 Vac 10 k AIR 2 Spaces Required 3P Common Trip 240 Vac 10 k AIR 3 Spaces Required
15 20
Cat. No. $ Price Cat. No. $ Price QO115CAFI 282.00 QO115VHCAFI 534.00 QO120CAFI 282.00 QO120VHCAFI 534.00
1P QO-GFI
QO-GFI Qwik-Gard circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Table 1.7:
Ampere Ratingc
QO-K
Key operated QO circuit breakers are available in singlepole construction and can be mounted in any single-pole space which will accept a standard QO. These circuit breakers can be turned ON or OFF or to RESET with a special key (catalog number QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available as shown in the table. Table 1.11: QO-K Circuit Breakers
120 Vac10 k AIR (1 Space Required) Ampere Rating c 10 15 20 25 30 Cat. No. QO110K QO115K QO120K QO125K QO130K $ Price 164.00 164.00 164.00 164.00 164.00
22 k AIR
1 Space Required 2 Spaces Required $ Price 413. 413. 413. 413. 413. 413. 413.
2P QO-GFI
15 20 25 30 40 50 60
$ $ Cat. No. Price Cat. No. Price Cat. No. 233. QO115VHGFI 482. QO215GFI 233. QO120VHGFI 482. QO220GFI 233. QO125VHGFI 482. QO225GFI 233. QO130VHGFI 482. QO230GFI QO240GFI QO250GFI QO260GFId
QO-HM
High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.12: QO-HM Circuit Breakers
Ampere Ratingc 120 Vac10 k AIR 15 A 20 A 1P Cat. No QO115HMab QO120HMab $ Price 30.60 30.60
QO-EPD/EPE
QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 milliampere level (EPD) or 100 milliamp level (EPE). They are not designed to protect people from electrical shock. Table 1.8:
Ampere Ratingc 1P 120 Vac 10 k AIR 1 Space Required
$ $ $ $ Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 15 QO115EPD 410. QO215EPD 660. QO315EPDe1077. QO315EPEe 1077. 20 QO120EPD 410. QO220EPD 660. QO320EPDe1077. QO320EPEe 1077. 25 QO125EPD 410. QO225EPD 660. 30 QO130EPD 410. QO230EPD 660. QO330EPDe1077. QO330EPEe 1077. 40 QO240EPD 660. QO340EPDe1077. QO340EPEe 1077. 50 QO250EPD 660. QO350EPDe1077. QO350EPEe 1077. 60 QO260EPDd 660.
QO-SWN
Switch Neutral Common Trip 2008 NEC 514.11 Table 1.9:
Two-wire QO-SWN
Ampere Ratingc
Three-wire QO-SWN
10 15 20 25 30 40 50
Interrupting Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-12 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54
DE2A
Discount Schedule
1-3
15 20 25 30 40 50
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price QO115HIDb 38.10 QO215HID 87.00 QO315HID 300.00 QO120HIDb 38.10 QO220HID 87.00 QO320HID 300.00 QO125HID 38.10 QO225HID 87.00 QO325HID 300.00 QO130HID 38.10 QO230HID 87.00 QO330HID 300.00 QO140HID 38.10 QO240HID 87.00 QO150HID 38.10 QO250HID 87.00
LOAD CENTERS
Accessories
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
Table 1.14:
1
LOAD CENTERS
Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P Converts any two adjacent 120/240 Vac1P side-by-side QOT circuit breakers to independent trip 2P Handle Clamp: Clamp for holding QO 1P handle in ON or OFF position Clamp for holding QO or Q1 either 1P 2P or 3P circuit breaker handles in ON or OFF position , For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment Fixed attachment For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position Handle Padlock Attachment: for Padlocking in ON or OFF position For padlocking 2P QO-GFI circuit breakers in either ON or OFF position, fixed attachment. For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment Fixed attachment For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. Handle Padlock Attachment: for Padlocking in OFF position For padlocking 1P QO-GFI, QO-AFI and QO-EPD circuit breakers in OFF position only, fixed attachment. For padlocking 2P QO-GFI and QO-EPD circuit breakers in OFF position only, fixed attachment. Ring Terminal Ring terminals are available as a factory-installed option. Sub-feed Lugs 60 A 2P plug-on 2 spaces required (62 Al/Cu) 125 A 2P plug-on 2 spaces required (122/0 Al/Cu) 225 A 2P plug-on 4 spaces required (4300 Al/Cu) 125 A 3P plug-on 3 spaces required (122/0 Al/Cu) For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted Mechanical Interlock Attachment side-by-side so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed With Retaining Kit: circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. a Not suitable for use in 3 panels. Use only in 1 panel rated 150 A or greater.
Factory-Installed Accessories for use with QO and QOB Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on QO, QO-GFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factoryinstalled accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers or on QO2150, QO2175, or QO2200 circuit breakers. Table 1.15:
Accessory
Factory-Installed Accessories
Description Coil Cat. No. Burden Suffix 60 VA -1042 168 VA 72 VA 228 VA -1021 288 VA $ Price Adder 189.00 189.00 Auxiliary Switches Accessory Description Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Application 1A 1B 120 Vac 120 Vac 5A 5A -1200 -1201 132.00 132.00 Contact Max. Max. Cat. No. $ Price Comb. Voltage Load Suffix Adder
Rated Voltage 12 Vac/Vdc 24 Vac/Vdc 120 Vac Trips the circuit breaker from a remote location by means of a trip 208 Vac coil energized from a separate 240 Vax circuit. A 120 Vac shunt trip will operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. Application For use with momentary or maintained push button. Not available on QO-GFI, QO-EPD. Shunt trip terminals accept (2) 0.14 0.12 AWG Cu.
Shunt Trip
Auxiliary switch terminals accept (2) 1412 AWG Cu leads. Leads (EH): Yellow for A, Blue for B, Striped common 18 AWG Cu.
Alarm Switches
Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normally-open contact. Application
1A
120 Vac
5A
-2100
132.00
1-4
DE2
DE2A
DE2E
DE3
Discount Schedule
QO Load Centers
www.schneider-electric.us
I N D O O R
Fixed MainsFactory-Installed Main Lugs10 kA Short Circuit Current Ratingb 30 A 2 2 0 41.70 QO2L30Scd 41.70 1210 1410 PK3GTA1 11.40 70 A 2 4 2 69.00 QO24L70F/Sef 69.00 Cover IncludedWithout Door 123 144 PK4GTA 10.80 87.00 QO612L100F/Seg 87.00 81 PK7GTA 11.70 6 12 6 90.00 QO612L100DF/Seg 90.00 Cover IncludedWith Door 81 PK7GTA 11.70 100 A 131.00 QO816L100F/Seg 131.00 Cover IncludedWithout Door 8 16 8 81 PK7GTA 11.70 143.00 QO816L100DF/Seg 143.00 Cover IncludedWith Door 6 12 6 111.00 QO612L100DFCU/SCUegh 111.00 Cover IncludedWith Door 81 PK7GTA 11.70 100 A 8 16 8 174.00 QO816L100DFCU/SCUegh 174.00 Cover IncludedWith Door 81 PK7GTA 11.70 125 A 4 8 4 93.00 QO148L125GF/Sei 93.00 Cover IncludedWithout Door 122/0 142/0 PK7GTAl Convertible MainsFactory-Installed Main Lugs65 kA Short Circuit Current Rating QOM1 Main Frame SizeConvertible to Main Circuit BreakerCu Busbj 12 12 0 196.70 QO112L125G 159.00 QOC16UF QOC16US 37.70 PK9GTAl 12 24 12 235.70 QO11224L125G 198.00 QOC16UF QOC16US 37.70 PK15GTAl 16 16 0 255.70 QO116L125G 218.00 QOC24UF QOC24US 37.70 PK12GTAl 16 24 8 300.70 QO11624L125G 263.00 QOC24UF QOC24US 37.70 PK15GTAl 125 A 62/0 20 20 0 271.70 QO120L125G 234.00 QOC24UF QOC24US 37.70 PK15GTAl 20 24 4 370.70 QO12024L125G 333.00 QOC24UF QOC24US 37.70 PK15GTAl 24 24 0 381.70 QO124L125G 344.00 QOC24UF QOC24US 37.70 PK15GTAl 32 32 0 434.60 QO132L125G 395.00 QOC32UF Use Flush 39.60 PK23GTA, LK100ANl Convertible MainsFactory-Installed Main Lugs65 kA Short Circuit Current Rating , QOM2 Main Frame SizeConvertible To Main Circuit BreakerCu Busbj 20 30 10 419.00 QO12030L150G 332.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 150 A 24 24 0 431.00 QO124L150G 344.00 QOC30UF QOC30US 87.00 6250 PK15GTAl 30 30 0 437.00 QO130L150G 350.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 12 12 0 353.00 QO112L200G 266.00 QOC30UF QOC30US 87.00 PK15GTAl 24 36 12 819.00 QO12436L200TFTk 732.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl 30 30 0 494.00 QO130L200G 407.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 200 A 30 40 10 554.00 QO13040L200G 467.00 QOC30UF QOC30US 87.00 6250 PK23GTA, LK100ANl 40 40 0 746.00 QO140L200G 659.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl 40 60 20 944.00 QO14060L200G 857.00 QOC40UF QOC40US 87.00 (2) PK15GTAl New! 42 52 10 921.00 QO14252L200G 810.00 QOC42UF QOC42US 111.00 (2) PK15GTAl 225 A 42 42 0 828.00 QO142L225G 717.00 QOC42UF QOC42US 111.00 6300 PK23GTA, LK100ANl Fixed MainsFactory-Installed Main Lugs65 kA Short Circuit Current Ratingbj QONQ30LS400 (Int) 1080.00 (1) 1/0750 400 A 30 30 0 1641.00 NC50NQVF NC50NQVS 486.00 33.80 MH50 (box)o 75.00 or (2) 1/0300 PK27GTAn or QONQ42LS400 (Int)m 1185.00 (1) 1/0750 PK15GTA6 53.00 400 A 42 42 0 1746.00 NC50NQVF NC50NQVS 486.00 MH50 (box) 75.00 or (2) 1/0300
1 2 4 4 4 4 4 21 6 6 7 7 7 7 7 8 9 9 9 9 10 9 9 10 10 11 11
15 15
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c Will not accept QO-EPD or Qwik-Gard QO-GFI or QO-AFI circuit breakers. d Mains rated 25 A when Al wire is used. e Order F for flush device or S for surface device. f Use 10 AWG maximum size wire for GFI and AFI circuit breakers. g 70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker. h CU indicates copper bus. i Copper bus. j UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. k Supplied with feed-thru lugs. l Factory-included. m Interior only, order box separately. n PK27GTA includes a 62/0 AWG Al/Cu lug. o PE1A Discount Schedule.
QO120L125G
Field-Installed Main Circuit Breaker (Use with Convertible Load Centers Only)
QOM1 Frame Size Convertible Load Center Mains Rating 22 k AIRq Main Circuit Breaker Ratingp QOM2 Frame Sizes Convertible Load Center Mains Rating
p q r
22 k AIRq Lug Wire Sizer Lug Wire Sizer Main Circuit Main Circuit AWG/kcmil AWG/kcmil $ Price $ Price Breaker Breaker 50 A 100125 QOM50VH 140.00 100 A 150225 QOM2100VH 468.00 60 A 100125 QOM60VH 140.00 125 A 150225 QOM2125VH 468.00 70 A 100125 QOM70VH 140.00 150 A 150225 QOM2150VH 468.00 4300 Al or Cu 80 A 100125 QOM80VH 201.00 175 A 200225 QOM2175VH 468.00 122/0 Al or Cu 90 A 100125 QOM90VH 201.00 200 A 200225 QOM2200VH 468.00 100 A 100125 QOM100VH 201.00 225 A 225 QOM2225VH 468.00 110 A 125 QOM110VH 468.00 125 A 125 QOM125VH 468.00 Do not exceed the load center mains rating. 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00.
DE3A
PE1A
Discount Schedule
1-5
LOAD CENTERS
QO Load Centers
1
Mains Rating
LOAD CENTERS
I N D O O R
Convertible Mains Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating, Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),b QOM1 Main Circuit Breaker Frame SizeCopper Bus 12 12 0 339.70 QO112M100 302.00 QOC12UF 16 16 0 379.70 QO116M100 342.00 QOC20U100F 100 A 20 20 0 433.70 QO120M100 396.00 QOC20U100F 24 24 0 553.70 QO124M100 516.00 QOC24UF 32 32 0 726.70 QO132M100 689.00 QOC32UF 24 24 0 819.70 QO124M125 782.00 QOC24UF 125 A 32 32 0 1041.60 QO132M125 1002.00 QOC32UF Convertible Mains Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5) b QOM2 Main Circuit Breaker Frame SizeCopper Bus 20 30 10 821.00 QO12030M150 734.00 QOC30UF 24 24 0 849.00 QO124M150 762.00 QOC30UF 150 A 30 30 0 854.00 QO130M150 767.00 QOC30UF 32 32 0 969.00 QO132M150 882.00 QOC40UF 20 40 20 821.00 QO12040M200 734.00 QOC30UF 24 24 0 866.00 QO124M200 779.00 QOC30UF 24
61 62/0 62/0
5 6 6 7 8 7 8
4250
36 12 1287.00 QO12436M200TFTh 1200.00 QOC40UF QOC40US 87.00 10 4250 QO130M200 792.00 QOC30UF QOC30US 87.00 18.80 9 30 30 0 879.00 30 40 10 957.00 QO13040M200 870.00 QOC30UF QOC30US 87.00 21.30 9 40 40 0 1121.00 QO140M200 1034.00 QOC40UF QOC40US 87.00 21.30 10 40 60 20 1431.00 QO14060M200 1344.00 QOC40UF QOC40US 87.00 21.30 10 42 42 0 1220.00 QO142M200 1109.00 QOC42UF QOC42US 111.00 21.30 11 New! 42 52 10 1382.00 QO14252M200 1271.00 QOC42UF QOC42US 111.00 21.30 11 4300 40 40 0 1196.00 QO140M225 1085.00 QOC42UF QOC42US 111.00 21.30 11 225 A 42 42 0 1253.00 QO142M225 1142.00 QOC42UF QOC42US 111.00 21.30 11 Fixed MainsFactory-installed LAL Main Circuit Breaker, 42 kA Short Circuit Current Ratingc QONQ42MS300 4243.00 (1) 4500 (int)d 300 A 42 42 0 4909.00 NC62NQVF NC62NQVS 591.00 16 PK27GTAe 33.80 MH62 (box)f 75.00 or (2) 43/0 or QONQ42MS400 PK15GTA6 53.00 4243.00 (1) 4500 (int)d NC62NQVF NC62NQVS 591.00 16 400 A 42 42 0 4909.00 MH62 (box)f 75.00 or (2) 4250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. c UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H circuit breakers only. d Interior only, order box separately. e PK27GTA includes a 62/0 Al/Cu lug. f PE1A Discount Schedule. g Factory included. h Supplied with feed-thru lugs. 200 A
PK18GTA PK15GTA PK18GTA PK18GTA PK23GTA PK15GTA PK23GTA and LK100ANg PK18GTA PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA
9 9 9 10 9 9
Use on Lug Wire Sizej Convertible Load Center Cat. No. $ Price AWG/kcmil with Mains Rating Al or Cu 125 A 100125 A QOL125k 44.10 62/0 225 A 150225 A QOL225k 104.00 6300 i Do not exceed the load center mains rating. j Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under main wire size. k If main circuit breaker knockout has been removed from the load centers trim, order appropriate filler plate from page 1-13.
QOL125
QOL225
QO130M150
1-6
DE3A
PE1A
Discount Schedule
QO Load Centers
www.schneider-electric.us
Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 1-2 and 1-3.)
Spaces Max. Single Pole Circuitsa Max. Tandem Circuit Breakers $ Price (Interior, Box and Cover) Load Center Box and Interior Cat. No. $ Price Main Wire Size AWG/kcmil Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Box No. See Page 1-17
Non-Metallic Enclosure
Fixed MainsFactory-installed Main Lugs10 kA Short Circuit Current Rating 60 A 2 4 2 102.00 QO24L60NRNM 102.00 144 144 Factory-installed 1NM
Metallic Enclosure
Fixed MainsFactory-installed Main Lugs10 kA Short Circuit Current Rating 40 A 2 2 0 113.00 QO2L40RBb 70 A 2 4 2 131.00 QO24L70RBb 6 12 6 143.00 QO612L100RBc 100 A 6 12 6 158.00 QO612L100TRBc 8 16 8 231.00 QO816L100RBc 6 12 6 174.00 QO612L100RBCUcd 100 A 8 16 8 279.00 QO816L100RBCUcd 125 A 4 8 4 152.00 QO148L125GRBd Convertible MainsFactory-installed Main Lugs65 kA Short Circuit Currentefg QOM1 Main Frame SizeConvertible to Main Circuit BreakerCopper Bus 12 12 0 285.00 QO112L125GRB 12 24 12 365.00 QO11224L125GRB 125 A 16 24 8 435.00 QO11624L125GRB 24 24 0 522.00 QO124L125GRB Convertible MainsFactory-installed Main Lugs65 kA Short Circuit Currentefg QOM2 Main Frame SizeConvertible to Main Circuit BreakerCopper Bus 150 A 30 30 0 587.00 QO130L150GRB 12 12 0 480.00 QO112L200GRB 30 30 0 666.00 QO130L200GRB 30 40 10 714.00 QO13040L200GRB 200 A 40 40 0 971.00 QO140L200GRB 40 60 20 1262.00 QO14060L200GRB New! 42 52 10 1194.00 QO14252L200GRB 225 A 42 42 0 1310.00 QO142L225GRB 113.00 131.00 143.00 158.00 231.00 174.00 279.00 152.00 126 123 81 81 122/0 142/0 146 144 PK3GTA1 PK4GTA PK7GTA Factory-installed PK7GTA PK7GTA PK7GTA PK7GTA Factory-included 11.40 10.80 11.70 11.70 11.70 11.70 1R 1R 2R 2R 2R 2R 2R 15R
R A I N P R O O F
62/0
3R 3R 4R 4R
4250
4250
4300
PK23GTA, LK100AN Factory-included PK9GTA Factory-included PK23GTA, LK100AN Factory-included PK23GTA, LK100AN Factory-included PK23GTA, LK100AN Factory-included (2) PK15GTA, (1) LK100AN Factory-included (2) PK15GTA, (1) LK100AN Factory-included PK23GTA, LK100AN Factory-included
6R 5R 6R 6R 7R 7R 8R 8R
Main Circuit Breaker Order QO, QOT, QO-GFI, QO-AFI, QO-EPD and QO-PL branch circuit breakers from pages 1-2 and 1-3.
Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers $ Price (Interior, Box and Cover) Load Center Box and Interior Cat. No. $ Price Main Wire Size AWG/kcmil Al or Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Box No. See Page 1-17
R A I N P R O O F
Convertible Mains Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg QOM1 Main Circuit Breaker Frame SizeCopper Bus 12 12 0 461.00 QO112M100RB 461.00 100 A 16 16 0 504.00 QO116M100RB 504.00 20 20 0 552.00 QO120M100RB 552.00 125 A 24 24 0 954.00 QO124M125RB 954.00 Convertible Mains Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg QOM2 Main Circuit Breaker Frame SizeCopper Bus 20 30 10 953.00 QO12030M150RB 953.00 150 A 30 30 0 1122.00 QO130M150RB 1122.00 20 40 20 954.00 QO12040M200RB 954.00 30 30 0 1154.00 QO130M200RB 1154.00 30 40 10 1179.00 QO13040M200GRB 1179.00 200 A 40 40 0 1397.00 QO140M200RB 1397.00 40 60 20 1815.00 QO14060M200RB 1815.00 42 42 0 1469.00 QO142M200RB 1469.00 New! 42 52 10 1718.00 QO14252M200RB 1718.00 225 A 42 42 0 1631.00 QO142M225RB 1631.00 QOM1/QOM2 Feed-Thru Main Circuit Breaker With Feed-Thru LugsCopper Bus, 22 kA Short Circuit Current Rating h 125 A 6 12 6 620.00 QO1612M125FTRBi 620.00 150 A 8 16 8 863.00 QO1816M150FTRBi 863.00 200 A 8 16 8 863.00 QO1816M200FTRB i 863.00
62/0 62/0
3R 4R 4R 4R
4250
4250
PK18GTA PK18GTA PK23GTA PK18GTA PK23GTA PK23GTA PK15GTA PK23GTA PK15GTA PK23GTA PK12GTA PK15GTA-L PK15GTA-L
18.80 18.80 21.30 18.80 21.30 21.30 17.10 21.30 17.10 21.30 15.80 35.00 35.00
5R 6R 5R 6R 6R 7R 7R 8R 8R 8R 3R 6R 6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Use 10 AWG maximum size wire for AFI and GFI circuit breaker. c 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. d Copper bus. e UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. f UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. g Side hinge door device; allow 1-1/4 in. on left side for door to open. h 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22 kA available fault current. i QO1612M125FTRB provided with QOM1 frame main circuit breaker. QO1816M150FTRB and QO1816M200FTRB provided with QOM2 frame main circuit breaker.
DE3A
Discount Schedule
1-7
LOAD CENTERS
QO Load Centers
Table 1.22:
34W 208Y/120 Vac, 34W 240/120 Vac Delta and 33W 240 Vac Delta, UL Listed.
Max. Number of 1P QO circuit breakers $ Price (Interior, Box and Cover) Load Center Box and Interior Cat. No. $ Price Indoor Cover with Door (Order Separately) Flush Cat. No. Surface Cat. No. $ Price Al Main Wire Size AWG/kcmil Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Pricej Box No. See Pages 1-17
1
LOAD CENTERS
(Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 1-2 and 1-3.) Mains Rating
I N D O O R
Fixed MainsFactory-installed Main LugsCopper Bus65 kA Short Circuit Current Rating a 60 A 3 107.00 QO403L60NF/S 107.00 Cover Included With Load Center (No Door) 12 369.70 QO312L125Gh 332.00 QOC16UF QOC16US 37.70 i 125 A 20 508.70 QO320L125Gh 471.00 QOC24UF QOC24US 37.70 i 24 577.70 QO324L125Gh 540.00 QOC24UF QOC24US 37.70 i 18 530.00 QO318L200Gh 443.00 QOC30UF QOC30US 87.00 i 200 A 30 707.00 QO330L200Gh 620.00 QOC30UF QOC30US 87.00 i 225 A 42 953.00 QO342L225Gh 842.00 QOC42UF QOC42US 111.00 i
62/0 6250
6300 Convertible MainsFactory-installed QDL Main Circuit BreakerCopper Bus25 kA Short Circuit Current Rating b 100 A 27 1058.00 QO327M100c 971.00 QOC30UF QOC30US 87.00 i 42/0 125 A 30 1931.00 QO330MQ125dh 1839.00 QOC342MQF QOC342MQS 92.00 4300 30 1931.00 QO330MQ150dh 1839.00 QOC342MQF QOC342MQS 92.00 150 A 4300 42 2119.00 QO342MQ150dh 2027.00 QOC342MQF QOC342MQS 92.00 30 1931.00 QO330MQ200dh 1839.00 QOC342MQF QOC342MQS 92.00 200 A 4300 42 2119.00 QO342MQ200dh 2027.00 QOC342MQF QOC342MQS 92.00 225 A 42 2119.00 QO342MQ225dh 2027.00 QOC342MQF QOC342MQS 92.00 4300
PK4GTA Factory-incl.g Factory-incl.g Factory-incl.g Factory-incl.f Factory-incl.f Factory-incl.f PK15GTA PK18GTA PK18GTA PK23GTA PK18GTA PK23GTA PK23GTA
13 6 7 7 9 9 11 9 12 12 12 12 12 12
Fixed MainsFactory-installed Main LugsCopper Bus65 kA Short Circuit Current Ratingae 60 A 3 177.00 QO403L60NRB 177.00 106 PK4GTA 10.80 10R 12 485.00 QO312L125GRB 485.00 Factory Incl.g 3R 125 A 62/0 62/0 20 629.00 QO320L125GRB 629.00 Factory Incl.g 4R R Cover Included 18 618.00 QO318L200GRB 618.00 Factory Incl.f 6R A 200 A 6250 6250 I 30 839.00 QO330L200GRB 839.00 Factory Incl.f 6R N 225 A 42 1494.00 QO342L225GRB 1494.00 6300 6300 Factory Incl.f 8R P R Convertible MainsFactory-installed QDL Main Circuit BreakerCopper Bus25 kA Short Circuit Current Ratingb e O 100 A 27 1185.00 QO327M100RBc 1185.00 42/0 42/0 PK15GTA 17.10 6R O 125 A 30 2147.00 QO330MQ125RBd 2147.00 4300 4300 PK18GTA 18.80 14R F 150 A 30 2147.00 QO330MQ150RBd 2147.00 4300 4300 PK18GTA 18.80 14R Cover Included 18.80 14R 30 2147.00 QO330MQ200RBd 2147.00 PK18GTA 200 A 4300 4300 42 2333.00 QO342MQ200RBd 2333.00 PK23GTA 21.30 14R 225 A 42 2333.00 QO342MQ225RBd 2333.00 4300 4300 PK23GTA 21.30 14R Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. b 25 kA short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k AIR branch circuit breakers. c Includes factory-installed back fed QO3100VH main circuit breaker. d 65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers. e Side hinge door device allow 1-1/4 in. on left side for door to open. f PK23GTA and LK100AN. g PK15GTA. h For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating when QODX...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used). i DE3A Discount Schedule j DE2 Discount Schedule
Table 1.23:
Field-installed alternate main circuit breakers for QO 3 main circuit breaker load centers rated 70225 A. Do not exceed the load center main rating. Amperage 25 k AIR 65 k AIR 100 k AIRk 70 A QDL32070 QGL32070 QJL32070 80 A QDL32080 QGL32080 QJL32080 90 A QDL32090 QGL32090 QJL32090 100 A QDL32100 QGL32100 QJL32100 110 A QDL32110 QGL32110 QJL32110 125 A QDL32125 QGL32125 QJL32125 150 A QDL32150 QGL32150 QJL32150 175 A QDL32175 QGL32175 QJL32175 200 A QDL32200 QGL32200 QJL32200 225 A QDL32225 QGL32225 QJL32225 $ Price (DE2) 1784.00 2442.00 2796.00 When these 3P circuit breakers are used as the main circuit breaker of a 3 load center, the maximum AIR rating is 65 kA at 240 Vac and 100 kA at 208 Vac.
Table 1.24:
QO342MQ200
Field-installed main lugs for convertible 3 main circuit breaker load centers.
QO312L125G
1-8
DE3
DE3A
DE2
Discount Schedule
Table 1.25:
Order QO, QOT, QO-EPD, QO-GFI, and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.
Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No. $ Price Equipment Grounding Bar Kit (Order Separately) Cat. No. $ Price Al Main Wire Size AWG/kcmil Cu Box No. See Page 1-12
I N D O O R R A I N P R O O F
148 82
148 82
4 4
60
QO48M60DSGP
563.00
PK7GTA
11.70
Generator Panels with Power Inlet Plug for Sub-Feed Applications Type 3R (Outdoor) 1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating 4 8 4 QO1DM10020TRBR 848.00 4 8 4 QO1DM10030TRBR 848.00 100 4 8 4 QO1DM10050TRBR 1148.00 Factory-Installed
82
Generator PanelAutomatic Transfer Switch (Contact your local Square D Field Sales office for more information.) b 1-Phase 3-Wire 120/240 Vac Factory- or Field-Installed Main Circuit Breaker 22,000 RMS Sym. Ampere Short Circuit Current Rating 150 38 42 42 QO13842MX150 1349.00 PK23GTA 21.30 4250 4250 12 200 38 42 42 QO13842MX200 1499.00 PK23GTA 21.30 4250 4250 12 I N 38 42 42 QO13842MX225 1649.00 4250 4250 12 225 PK23GTA 21.30 D 38 42 42 QO13842UX225 c 1199.00 4250 4250 12 O QOC38MXUF (Cover) 149.00 O R 150 14 28 28 QO11428MX150FTRBde 1349.00 PK23GTA 21.30 4250 4250 7R 14 28 28 QO11428MX200FTRBde 1499.00 PK23GTA 21.30 4250 4250 7R 200 14 28 28 QO11428UX200FTRBcde 1199.00 PK23GTA 21.30 4250 4250 7R QO Load Center Accessories Cat. No. $ Price Schedule For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that QO2DTI 24.90 DE2E only one circuit breaker can be ON at a time. QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual QO2DTIM 63.00 DE2E power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back- PK4DTIM4LA Manual Transfer Equipment Kit up power supply applications. For 1 100125 ampere convertible main load centers. Series S01 and S02. 102.00 DE3A Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back- PK4DTIM4HA 102.00 DE3A up power supply applications. For 1 150225 ampere convertible main load centers. Series S01 and S02. Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up PK4DTIM4LAL 102.00 DE3A power supply applications. For 1 100125 ampere convertible main load centers. Series S01 and S02. For use on G and S Series NEMA 1 and G, S1 and S2 Series NEMA 3R load centers. Interlocks a QOM1 2P QOCRBGK1 105.00 DE3A main circuit breaker of a load center (100125 A) with a QO 2P (15125 A) branch circuit breaker. Includes a retaining kit. Generator Circuit Breaker For use on G and S Series NEMA 1 and G and S1 Series NEMA 3R load centers. Interlocks a QOM2 2P main QOCGK2 105.00 DE3A circuit breaker of a load center (150225 A) with a QO 2P (15125 A) branch circuit breaker. Includes a retaining kit. Interlock Kit For use on S2 Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150225 A) QORBGK2 105.00 DE3A with a QO 2P (15125 A) branch circuit breaker. Includes a retaining kit. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b One main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max.) ordered separately. Automatic Transfer Switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor. c Universal mains No factory-installed main circuit breaker or main lugs. QOM2 frame size, field-install 22 k AIR. Main circuit breaker or main lugs (see pages 1-5 or 1-6). d Supplied with feed-thru lugs. e Device is rated NEMA 3R and can be used for indoor or outdoor applications.
QO2DTI Installed
QO2DTI
OFF ON OFF ON
OFF
ON
DE3A
Discount Schedule
1-9
1
OFF ON
LOAD CENTERS
Generator Panels for Sub-Feed Applications Type 1 (Indoor) 1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating 30 4 8 4 QO48M30DSGP 563.00
QO Load Centers
Special Applications
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
Table 1.26:
Mains Rating
QO Special Application (Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.)
Short Circuit Current Rating Spaces Max. 1P Circuits a Max. Tandem Circuit Breakers Load Center b Box, Interior, and Cover Cat. No. $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Main Wire Size AWG/kcmil Al Cu Box No. See Page 1-17
1
LOAD CENTERS
0 2
QO2L30TTSd QO24L50TTSe
51.00 78.00
Factory-installed
1210 f 123 41
1410 146
1 2 3
12W 120 VacMain Circuit BreakerCSA Certified 30 A 10 kA 3 5 2 QO35FM30TTF/S 83.00 Factory-installed 13W 120/240 VacMain Lugs OnlyCSA Certified 70 A 10 kA 2 4 2 QO24L70TSe 78.00 10 kA 6 12 6 QO612L100TF/Sg 86.00 Factory 10 kA 6 12 6 QO612L100DTF/Sg 101.00 Installed 100 A 10 kA 8 16 8 QO816L100TF/Sg 137.00 10 kA 8 16 8 QO816L100DTF/Sg 159.00 Load Center with Cover: 13W 120/240 VacUL Listed Complete QO Load CenterBox, Interior and Combination Cover in One Package Convertible MainsFactory-Installed Main Lugs iQOM1 Main Frame SizeConvertible to Main Circuit Breaker (See page 1-5)Copper Bus 65 kA 12 0 QO112L125GC 188.00 PK12GTA Incl. 12 125 A 65 kA 12 24 12 QO11224L125GC 249.00 PK15GTA Incl. 20 65 kA 20 0 QO120L125GC 284.00 PK15GTA Incl. Convertible MainsFactory-Installed Main Lugs iQOM2 Main Frame SizeConvertible to Main Circuit Breaker (See page 1-5)Copper Bus 150 A 65 kA 30 30 0 QO130L150TC 452.00 PK23GTA, LK100AN Installed 200 A 65 kA 30 40 10 QO13040L200GC 575.00 PK23GTA, LK100AN Incl.
144
2 4 4 4 4
I N D O O R
6 6 7 9 9
Convertible MainsFactory-Installed Main Circuit Breaker QOM1 Main Frame SizeConvertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)Copper Bus j 22 kA 12 12 0 QO112M100C 351.00 PK9GTA 13.40 41/0 5 22 kA 12 20 8 QO11220M100C 413.00 PK15GTA 17.10 41/0 5 100 A 22 kA 16 16 0 QO116M100C 395.00 PK12GTA 15.80 41/0 6 22 kA 20 20 0 QO120M100C 446.00 PK15GTA 17.10 41/0 6 125 A 22 kA 32 32 0 QO132M125C 1041.00 PK18GTA 18.80 62/0 8 Convertible MainsFactory-Installed Main Circuit Breaker QOM2 Main Frame SizeConvertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)Copper Bus j 22 kA 20 30 10 QO12030M150C 843.00 PK18GTA 18.80 4250 9 150 A 22 kA 30 30 0 QO130M150C 870.00 PK18GTA 18.80 4250 9 22 kA 20 40 20 QO12040M200C 843.00 PK23GTA 21.30 4250 9 22 kA 30 30 0 QO130M200C 896.00 PK18GTA 18.80 4250 9 200 A 22 kA 30 40 10 QO13040M200C 974.00 PK23GTA 21.30 4250 9 22 kA 40 40 0 QO140M200C 1137.00 PK23GTA 21.30 4250 10 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Order F for flush device or S for surface device. c Mains rating 25 A when Al wire is used. d Will not accept Qwik-Gard QO-GFI or QO-AFI circuit breaker. e Use 10 AWG maximum size wire for GFI and AFI circuit breakers. f Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2. g 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. h UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. i UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. j 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current.
Table 1.27:
Auxiliary Gutter
Cover Flush Conduit Riser Size 1-3/4, 2, 2-1/2 or l3 Width 13.50 Height 26.12 Depth 3.75
UL Listed for use with standard 1 and 3 load centers for riser applicationsk. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501 Cat. No. $ Price SDAG26 338.00 One tap kit required for each riser wire. When used with B300 bolt-on hubs.
k l
Table 1.28:
Tap Kits 120/240 VacUL Listed for use with Auxiliary Gutter SDAG26
$ Price 81.00 120.00 49.70 70.00 40.70 Use with Auxiliary Gutter Cat. No. SDAG26 SDAG26 SDAG26 SDAG26 SDAG26 Riser Wire Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL030516H1 (Not included) Anderson VCEL030516H1 (Not included) Mechanical (Included) Al/Cu Wire Size (2) 6 AWG300 kcmil (2) 6 AWG300 kcmil (2) 4 AWG300 kcmil (2) 4 AWG300 kcmil (2) 62/0 AWG Tap Off Wire Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL02114S1 (Not Included) Anderson VCEL030516H1 (Not included) Al/Cu Wire Size (1) 62/0 AWG (1) 6 AWG300 kcmil (1) 81/0 AWG (1) 4 AWG300 kcmil
1-10
DE3A
Discount Schedule
13W120/240 VacUL ListedConvertible MainsFactory-installed Main Circuit Breaker Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers
LOAD CENTERS
Max. 1P Circuitsa Max. Tandem Circuit Breakers Load Center Box, Interior, Cover and Branch Circuit Breakers Cat. No. Included Load Center/Circuit Breakers $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. Main Wire Size AWG/kcmil Al/Cu $ Price Box No. See Pages 1-17
Mains Rating
I N D O O R
QOCopper BusOrder extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 1-2 and 1-3. Main Circuit Breaker 100 A 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 200 A 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 200 A 30 40 10 QOVP10 (1) QO13040M200C, (10) QO120 HomelineOrder extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14. Main Lugs 125 A 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 200 A 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 Main Circuit Breaker 100 A 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 100 A 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 150 A 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 200 A 20 40 20 HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230 200 A 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 200 A 30 40 10 HOMVP2 200 A 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 200 A 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 200 A 40 40 0 HOMVP15 (1) HOM40M200C, (10) HOM120 HomelineOrder extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14. Main Circuit Breaker
8 9 9
353.00 962.00 528.00 528.00 983.00 965.00 1083.00 1083.00 1328.00 1328.00 1346.00
Included Included PK15GTA PK15GTA PK23GTA Included Included Included Included Included PK23GTA
62/0 4250 42/0 42/0 4250 4250 4250 4250 4250 4250 4250
6 10 7 7 10 9 10 10 10 10 12
R A I N P R O O F
200 A
20
40
20
HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250
1253.00
PK23GTA
21.30
4250
6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
Riser Panels
Table 1.30:
Mains Rating
13W 120/240 VacOffset Interior Wide Gutter30 A Maximum Branch Circuit Breaker on left side of interior bc
Spaces Max. Single Pole Circuitsd Max. Tandem Circuit Breakers Load Center Box and Interior Cat. No. $ Price Load Center Cover Cat. No. $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Main Wire Size AWG/kcmil Al Cu Box No. See Page 1-17
Convertible MainsFactory-installed Main Lugs65 kA Short Circuit Current Rating QOM1 Main Frame SizeConvertible to Main Circuit Breaker (See page 1-5) when used with QOC cover belowCopper Bus 125 A 12 24 12 QO11224L125WG 338.00 QOC20UFWG 53.00 PK15GTA I 125 A 20 30 10 QO12030L125WG 465.00 QOC20UFWG 53.00 PK15GTA N D Convertible MainsFactory-installed Main Lugs65 kA Short Circuit Current Rating O QOM2 Main Frame SizeConvertible to Main Circuit Breaker (See page 1-5) when used with QOC cover belowCopper Bus O 200 A 30 40 10 QO13040L200WG 701.00 QOC30UFWG 102.00 PK23GTA R Convertible MainsFactory-installed Main Circuit Breaker22 kA Short Circuit Current Rating QOM2 Main Frame SizeConvertible to Main Lugs (See page 1-6)Copper Bus 200 A 24 24 0 QO124M200WG125e 683.00 QOC30UFWG 102.00 PK23GTA Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. d Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. e Comes with 125 A main circuit breaker factory installed.
17.10 17.10
62/0 62/0
14 14
21.30
4250
23
21.30
4250
23
Mains Rating of Load Center Cat. No. 125 A NQC20FWG 200 A NQC30FWG Order catalog number PK4FL for field-installed lock kit.
DE3A
Discount Schedule
1-11
Table 1.31:
1
LOAD CENTERS
Retaining Kit
Miscellaneous
1-12
DE1B
DE2E
DE3A
DE5
Discount Schedule
Table 1.32:
Description Fills opening in covers if twistout is removed in error Fills main circuit breaker opening in convertible load center covers100125 A Filler Plates Fills main circuit breaker opening in convertible load center covers150225 A Fills main circuit breaker opening in 3 load center covers (S01 and S02 Series) Fills main circuit breaker opening in Q style 3 load center covers (S03 Series) Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU, QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP . Lock Kits Use with convertible mains, 1 and 3 100225 A, and fixed mains, 3 125225 A indoor load centers Use with 300 and 400 ampere indoor load centers. Field-installed for 12 2 Al or 144 Cu AWG wire Field-installed for 62/0 Al/Cu AWG wire Neutral / Ground Lugs Field-installed for 142/0 Al/Cu AWG wire Field-installed for 23/0 Al/Cu AWG wire Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150225 A QO or HOM load center Standard PK15GTA with a 14/0 Al/Cu Lug Standard PK18GTA with a 14/0 Al/Cu Lug Ground Bar Kits Standard PK23GTA with a 14/0 Al/Cu Lug Insulator Kit for PK7GTA through PK27GTA For padlocking main circuit breakers in convertible load centers OFF..........50125 A, QOM1 Frame Size Handle Padlock Attachment: For padlocking main circuit breakers in convertible load centers OFF..........100225 A, QOM2 Frame Size a QO403L60NF/S does not have provisions for a field-installed lock.
QOFP
Table 1.33:
Neutral Lugs
Retaining Kit
Field-installed for 142 AWG Al or 144 AWG Cu wire Field-installed for 62/0 AWG Al/Cu wire Field-installed for 142/0 AWG Al/Cu wire Field-installed for 4 AWG300 kcmil Al/Cu wire. Use in Series S, 150225 A QO or HOM load center Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100125 A convertible main load centers, Series S01 and S02 Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150225 A convertible main load centers, Series S01 and S02 Secures circuit breaker to interior when used as a back-fed main. For 2P 150200 A circuit breakers Use with convertible indoor load center covers (Series S-1) 1 through 42 numbered universal replacement directory label for load center covers
Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits Stickers: For use on S Series NEMA 1 and S1 and S2 Series NEMA 3R load centers. Interlocks a QOM1 2P main circuit breaker of a load center (100125 A) with a Homeline 2P (15125 A) branch circuit breaker. For use on S Series NEMA 1 and S1 Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150225 A) with a Homeline 2P (15125 A) branch circuit breaker. For use on S2 Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150225 A) with a Homeline 2P (15125 A) branch circuit breaker.
DE2E
DE3A
DE3B
DE3C
DE3D
DE3E
DE5
PE1A
Discount Schedule
1-13
LOAD CENTERS
Table 1.39:
Ampere Ratingd
1
LOAD CENTERS HOM 2P 2 Spaces Required HOM2200BB Branch Circuit Breaker 4 Spaces Required HOMT Quad Circuit Breaker 2 Spaces Required HOM 1P AFI (Arc Fault Circuit Interrupter) 1 Space Required HOM 1P GFI (With Ground Fault Circuit Interrupter) 1 Space Required HOM 2P GFI (With Ground Fault Circuit Interrupter) 2 Spaces Required
Table 1.34:
Ampere Rating 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A AIR 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA
HOM
1P120/240 Vac Cat. No. HOM115 ab HOM120 ab HOM125 b HOM130 b HOM140 b HOM150 b $ Price 26.30 26.30 26.30 26.30 26.30 26.30 2P120/240 Vac Common Trip Cat. No. HOM215 b HOM220 b HOM225 b HOM230 b HOM235 b HOM240 b HOM245 b HOM250 b HOM260 b HOM270 b HOM280 b HOM290 b HOM2100 b HOM2110 b HOM2125 b HOM2150BB bc HOM2175BB bc HOM2200BB bc $ Price 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 123.00 168.00 168.00 168.00 369.00 369.00 428.00 428.00 428.00
Cat. No. $ Price 15 and 15 A 10 kA HOMT1515 b 52.00 15 and 20 A 10 kA HOMT1520 b 52.00 20 and 20 A 10 kA HOMT2020 b 52.00 30 and 15 A 10 kA HOMT3015 b 52.00 30 and 20 A 10 kA HOMT3020 b 52.00 a UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. b UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers.
Table 1.40:
Ampere Rating d
Table 1.35:
HOM-HM
1P120/240 Vac Cat. No. HOM115HMb HOM120HMb $ Price 27.60 27.60 2Ps
High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. Amperes 15 A 20 A
1P 2P Cat. No. $ Price (2) 15 A 15 A 10 kA HOMT1515215 b 120.00 (2) 15 A 20 A 10 kA HOMT1515220 b 120.00 (2) 15 A 25 A 10 kA HOMT1515225 b 120.00 (2) 15 A 30 A 10 kA HOMT1515230 b 120.00 (2) 15 A 40 A 10 kA HOMT1515240 b 120.00 (2) 15 A 50 A 10 kA HOMT1515250 b 120.00 (2) 20 A 20 A 10 kA HOMT2020220 b 120.00 (2) 20 A 25 A 10 kA HOMT2020225 b 120.00 (2) 20 A 30 A 10 kA HOMT2020230 b 120.00 (2) 20 A 40 A 10 kA HOMT2020240 b 120.00 (2) 20 A 50 A 10 kA HOMT2020250 b 120.00 Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common trip (one 30 A 2P CB).
Table 1.41:
Breaker Type
Table 1.36:
HOM-AFI
HOM 1P
Homeline Combination Arc Fault Circuit InterruptersProvide overload and short circuit protection, plus arc fault protection in accordance with the NEC and UL 1699. Circuit Breaker Type Combination Arc-fault Circuit interrupter Ampere Rating 15 A 20 A Poles 120 Cat. No. Vac 1 HOM115CAFIb 1 HOM120CAFIb $ Price 267.00 267.00
Table 1.37:
HOM-GFI
HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. 1P120 Vac Ampere Rating 15 A 20 A 30 A 40 A 50 A AIR 1 Space Required Cat. No. HOM115GFI HOM120GFI $ Price 212.00 212.00 2P120/240 Vac Common Trip 2 Spaces Required Cat. No. HOM215GFI HOM220GFI HOM230GFI HOM240GFI HOM250GFI $ Price 413.00 413.00 413.00 413.00 413.00
Table 1.42:
Accessories
10 kA 10 kA 10 kA 10 kA 10 kA
Table 1.38:
HOM-EPD10 k AIR
Homeline Equipment Protection DeviceCircuit Breakers with 30 mA Equipment Ground Fault Protection (UL Listed) 2P120/240 Vac 1P120 Vac Common Trip Amperes 15 A 20 A 25 A 30 A 40 A 50 A Cat. No. HOM115EPD HOM120EPD $ Price 374.00 374.00 Cat. No. HOM215EPD HOM220EPD HOM225EPD HOM230EPD HOM240EPD HOM250EPD $ Price 660.00 660.00 660.00 660.00 660.00 660.00
Description Cat. No. $ Price Handle Attachments Handle Tie: Converts any two adjacent 120/240 Vac HOM1HTg 3.50 single HOM circuit breakers to independent trip 2P Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side HOMT circuit breakers to independent HOMTHTg 3.80 trip 2P Handle Clamp: Clamp for holding HOM 1P handle in QO1LOh 3.80 the ON or OFF position Handle Blocking Device: Attaches to standard HOM 2P circuit breakers for holding the handle in the OFF HOM2HBDg 10.70 position Handle Padlock Attachment: For padlocking 1P HOM1PAg 9.90 Standard HOM breakers in the ON or OFF position. 1570 A HOM2PALAg 9.90 Handle Padlock Attachment: For padlocking 2P Standard HOM circuit 80125 A HOM2PAHAg 9.90 breakers in ON or OFF position 150200 A HOM2PAVHAg 50.00 Handle Padlock Attachment: For padlocking center HOMQPA 9.90 poles of Homeline Quad breakers in the OFF position. Handle Padlock Attachment: For 50125 A QOM1PAfh 11.00 padlocking main circuit breakers in 100225 A QOM2PAfh 11.00 convertible load center in OFF position Sub-Feed Lugs 125 A 2P plug-on2 spaces required HOML2125 47.60 225 A 2P plug-on4 spaces required HOML2225c 296.00 c Requires four spaces (1 AWG300 kcmil Al/Cu). Use only in 1 panel rated 150 A or greater. d 1520 A tandem or quad tandem circuit breakers are suitable for use with 60oC or 75oC conductors. 2550 A tandem or quad tandem circuit breakers are suitable for use with 75oC conductors only. e 1530 A circuit breakers are suitable for use with 60oC or 75oC conductors. 40125 A circuit breakers are suitable for use with 75oC conductors. f 50125 A QOM1 frame size; 100225 A QOM2 frame size. g DE3C Discount Schedule h DE2E Discount Schedule
1-14
DE3D
DE3C
DE2E
Discount Schedule
Table 1.43:
Mains Rating
Main LugsOrder HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 1-14
Factory-installed Fixed Main Lugs 70 A 2 4 2 HOM24L70F/Sdc 100 A 6 12 6 HOM612L100F/Sce 125 A 4 8 4 HOM48L125GC Convertible MainsFactory-installed Main Lugs QOM1 Main Frame SizeConvertible to 22 k AIR Main Circuit Breaker (See page 1-16) 8 16 8 HOM816L125C 8 16 8 HOM816L125TC 12 12 0 HOM12L125C 12 24 12 HOM1224L125TC 125 A 16 24 8 HOM1624L125C 20 20 0 HOM20L125C 20 24 4 HOM2024L125TC 24 24 0 HOM24L125TC Convertible MainsFactory-installed Main Lugs QOM2 Main Frame SizeConvertible to 22 k AIR Main Circuit Breaker (See page 1-16) 30 30 0 HOM30L150C 150 A 30 30 0 HOM30L150TC 16 32 16 HOM1632L200TC 200 A 16 32 16 HOM1632L200TCFTf 20 40 20 HOM2040L200TC 30 30 0 HOM30L200C 30 30 0 HOM30L200TC 30 40 10 HOM3040L200TC 200 A 40 40 0 HOM40L200C 40 40 0 HOM40L200TC 40 60 20 HOM4060L200TC New! 42 52 10 HOM4252L200TC 225 A 42 42 0 HOM42L225C I N D O O R 59.00 78.00 86.00 123 81 122/0 142/0 144 PK3GTA1 11.40 PK7GTA 11.70 PK7GTA Factory-included 2 4 21
62/0
6 6 6 6 8 8 8 8
375.00 396.00 357.00 575.00 417.00 420.00 464.00 479.00 618.00 671.00 839.00 804.00 732.00
PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed Factory-installed Factory-installed PK23GTA
4250
6250
10 10 9 10 9 10 10 10 12 12 12 12 12
4250
4250
4250
Factory-installed Factory-installed PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed PK23GTA Factory-installed PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA
9 9 10 9 9 9 9 10 10 12 12 12 12 12
DE3A
DE3C
Discount Schedule
1-15
LOAD CENTERS
Table 1.44:
1
LOAD CENTERS
Mains Rating
Main Lugs (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 10 kA Short Circuit Current Rating
Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating 70 A 2 4 2 HOM24L70RBb 111.00 123 144 PK4GTA 10.80 100 A 6 12 6 HOM612L100RBf 129.00 81 PK7GTA 11.70 125 A 4 8 4 HOM48L125GRB 137.00 122/0 142/0 PK7GTA Factory-included Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame SizeConvertible to 22 k AIR Main Circuit Breaker (See Below) 8 16 8 HOM816L125RB 248.00 PK15GTA 17.10 12 12 0 HOM12L125RB 234.00 PK15GTA 17.10 125 A 62/0 12 24 12 HOM1224L125RB 278.00 PK15GTA 17.10 20 20 0 HOM20L125RB 383.00 PK15GTA 17.10 Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame SizeConvertible to 22 k AIR Main Circuit Breaker (See Below) 12 12 0 HOM12L200RB 423.00 PK23GTA 21.30 20 40 20 HOM2040L200RB 560.00 PK23GTA 21.30 30 30 0 HOM30L200RB 587.00 PK23GTA 21.30 200 A 30 40 10 HOM3040L200RB 759.00 4250 40 40 0 HOM40L200RB 911.00 PK23GTA 21.30 1R 2R 15R 3R 3R 3R 4R 5R 6R 7R 14R 14R 14R
R A I N P R O O F
New!
40 42
60 52
20 10
HOM4060L200RB HOM4252L200RB
1139.00 1092.00
PK23GTA PK23GTA
21.30 21.30
Main Circuit Breaker (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 22 kA Short Circuit Current Rating Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame SizeConvertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d 8 16 8 HOM816M100RB 429.00 61 PK15GTA 17.10 3R 12 12 0 HOM12M100RB 416.00 PK15GTA 17.10 3R 100 A 20 20 0 HOM20M100RB 531.00 62/0 PK15GTA 17.10 4R 24 24 0 HOM24M100RB 606.00 PK15GTA 17.10 6R 8 16 8 HOM816M125RB 716.00 PK15GTA 17.10 3R 125 A 62/0 24 24 0 HOM24M125RB 858.00 PK15GTA 17.10 6R Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame SizeConvertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) 150 A 30 30 0 HOM30M150RB 978.00 4250 PK23GTA 21.30 7R R 20 40 20 HOM2040M200RB 872.00 PK23GTA 21.30 6R A 30 30 0 HOM30M200RB 1004.00 PK23GTA 21.30 7R I N 30 40 10 HOM3040M200RB 1152.00 PK23GTA 21.30 7R 200 A 4250 P 40 40 0 HOM40M200RB 1277.00 PK23GTA 21.30 14R R 40 60 20 HOM4060M200RB 1596.00 PK23GTA 14.20 14R O New! O 42 52 10 HOM4252M200RB 1532.00 PK23GTA 14.20 14R F 16 24 8 HOM1624M225RB 1182.00 PK15GTA 17.10 7R 225 A 4250 42 42 0 HOM42M225RB 1323.00 PK23GTA 21.30 14R Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs c 150 A 8 16 8 HOM816M150FTRB 785.00 4250 PK15GTAL 35.00 6R 200 A e 8 16 8 HOM816M200FTRB 785.00 4250 PK15GTAL 35.00 6R Universal Main with Feed-thru LugsNo Factory-installed Main Circuit Breaker or Main Lugs c QOM2 Main Frame SizeField-install 22 k AIR Main Circuit Breaker or Main Lugs (See Kits Below) 200 A 8 16 8 HOM816U200FTRB 446.00 4250 PK15GTAL 35.00 6R Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. c Side hinge door device allow 1-1/4 in. on left side for door to open. d 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. e Rated 200 A when using copper wire. Reference NEC Table 310.15(B)(6) when using Al wire. f 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
Field-Installed Kits
Table 1.45:
Main Lug Kit
Field-Installed Main Type
QOL125
QOL225
Main g Use on Convertible Load $ Price Lug Wire Size j Cat. No. Ampere Rating Center with Mains Rating (DE3A) AWG/kcmil 125 A 100125 A QOL125 44.10 62/0 Al or Cu Main Lug h 225 A 150225 A QOL225 104.00 6300 Al or Cu 50 A 100125 A QOM50VH 140.00 60 A 100125 A QOM60VH 140.00 70 A 100125 A QOM70VH 140.00 80 A 100125 A QOM80VH 201.00 QOM1 122/0 Al or Cu 90 A 100125 A QOM90VH 201.00 100 A 100125 A QOM100VH 201.00 110 A 125 A QOM110VH 468.00 Main Circuit Breaker i 125 A 125 A QOM125VH 468.00 100 A 150225 A QOM2100VH 468.00 125 A 150225 A QOM2125VH 468.00 150 A 150225 A QOM2150VH 468.00 QOM2k 4300 Al or Cu 175 A 200225 A QOM2175VH 468.00 200 A 200225 A QOM2200VH 468.00 225 A 225 A QOM2225VH 468.00 g Do not exceed the load center mains rating. h If main circuit breaker knockout has been removed from the load centers trim, order appropriate filler plate from page 1-13. i 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. j Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. k Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00.
1-16
DE3A
DE3C
Discount Schedule
A,B,C,D A,B,C
Enclosure Dimensions
Dimensions Dimensions D mm 171 236 236 319 379 455 531 661 758 858 965 1000 in. 3.00 3.19 3.19 3.80 3.75 3.75 3.75 3.75 3.75 3.75 3.75 3.75 mm 76 81 81 97 95 95 95 95 95 95 95 95 in. 5.88 14.25 20.00 20.00 20.00 5.88 7.56 9.62 8.88 8.55 14.25 mm 149 362 508 508 508 149 192 244 226 217 362 in. 13.12 20.92 50.00 62.00 53.00 16.12 23.12 26.12 14.80 23.92 29.86 mm 333 531 1270 1727 1346 409 587 663 376 608 758 in. 3.38 3.75 5.75 5.75 5.75 3.38 4.25 4.75 3.80 3.95 3.75 mm 86 95 146 146 146 86 108 121 97 100 95 H Box No. 13 14 15 16 17 18 19 20 21 22 23 W H D
A,B
Box 1
Box 2
Box 3
A,B B,C,D,E
B,C,D,E B,C,D,E
B,C,D,E C,D,E,F
C,D,E,F,G
A A,B B,C,D,E
Table 1.47:
Symbol Conduit Size A 1/2 B
Knockout Information
Knockouts C 1 D E F 2 G 2-1/2 H 3 I 3-1/2
B,C,D,E C,D,E,F A A,B B,C,D,E D,E,F,G D,E,F,G B,C A,B C,D,E,F,G A A,B B,C,D,E D,E,F,G
Box 4
Box 5
3/4
1-1/4 1-1/2
B,C,D,E B,C,D,E B,C,D,E C,D,E,F C,D,E,F,G A A,B B,C,D,E C,D,E,F C,D,E,F,G A A,B B,C,D,E C,D,E,F
C,D,E,F,G
A A,B
C,D,E,F,G
A,B A,B A A A
A,B,C,D
A,B,C,D
B,C,D,E
A,B,C,D
D,E,F,G
A,B,C,D C,D,E,F
D,E,F,G
A,B,C,D C,D,E,F
Box 6
Box 7
Box 8
Box 9
Box 10
C,D,E,F,G
C,D,E,F,G
A,B
D,E,F,G,H
D,E,F,G,H,I
B,C,D,E
A,B
D,E,F,G
A,B,C,D C,D,E,F
C,D,E,F
A,B,C,D B,C,D,E
A,B,C,D B,C,D,E
Box 11
Box 12
Box 13
Box 14
A,B,C A C,D,E,F D,E,F,G C,D,E,F E,F,G,H C,D,E,F A,B,C,D D,E,F,G D,E,F,G A,B B,C,D,E A B,C,D,E B,C,D,E B,C A,B
Box 18
Box 19
Box 20
Box 21
Box 22
Box 23
1-17
LOAD CENTERS
1
A,B A,B B,C B,C
Table 1.48:
Box No.
Enclosure Dimensions
Dimensions W D mm 223 238 321 481 560 661 758 858 965 165 335 590 666 411 1000 376 629 321 in. 3.90 4.00 4.27 4.52 4.52 4.52 4.52 4.52 4.52 3.88 4.12 4.75 5.50 4.12 4.52 4.27 4.16 4.27 mm 99 102 108 115 115 115 115 115 115 99 105 121 140 105 115 108 106 108
A,B,C,D
A A,B
B,C,D,E A B,C,D,E
B,C,D,E A,B
Box 1R
Box 2R
2 1 2" Hub Maximum
C,D,E,F,G
C,D,E,F,G
C,D,E,F
C,D,E,F
Box 3R, 4R
2 1 2" Hub Maximum
C,D,E,F
C,D,E,F
Box 5R
a
H in. mm in. 1NM 6.52 166 8.79 1Ra 4.88 124 9.38 2R 8.88 226 12.65 3R 14.75 375 18.92 4R 14.75 375 22.06 5R 14.75 375 26.04 6R 14.75 375 29.86 7R 14.75 375 33.78 8R 14.75 375 37.98 9R 4.56 116 6.50 10R 6.92 176 13.18 11R 7.56 192 23.24 12R 9.62 244 26.24 13R 6.92 176 16.18 14R 14.75 375 39.37 15R 8.88 226 14.80 16R 8.55 217 24.75 17R 8.88 226 12.65 HOME250SPA and QO260NATR top endwall has no hub opening.
LOAD CENTERS
Table 1.49:
C,D,E,F,G A,B,C
Knockout Information
Knockouts A 1/2 in. B 3/4 in. C 1 in. D 1-1/4 in. E 1-1/2 in. F 2 in. G 2-1/2 in. H 3 in.
Box 9R
C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F
Box 11R
C,D,E,F A,B,C,D B,C,D,E
Box 15R
C,D,E,F,G
B,C,D,E
B, C, D, E B, C, D, E
Box 16R
Bolt-On Hubs
Square D equipment with R or RB suffix, designated NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. RB devices will accept 3/4 in. through 2-1/2 in. bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix R devices require 3 in. through 4 in. field cut opening. Hubs are suitable for use with conduit having ANSI standard taper pipe thread. Table 1.50:
Conduit Size Hub Cat. No. $ Price b
Closing cap (Cat. No. BCAP) is provided factory-installed on each device having RB suffix. Price if ordered separately; $2.50
Table 1.51:
RB Hub
Conduit Size Hub Cat. No. $ Price
1-18
DE1A
Discount Schedule
Table 1.52:
Meter Mains
New!
Load Center and Branch Circuit Breakers (Order separately Pages 1-2, 1-3, 1-4) Max. Quantity Spaces 1P Circuits Tandems
Meets Federal Spec. W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 13W, NEMA 3R enclosure Service Disconnect(s) Service (Type of Feed) Ampere Rating Bypass Type Short Circuit Current Rating Cat. No. $ Price Type 2P separately Ampere Circuits (Orderpage 1-22 Rating from (Max.) except as noted) (Max.) Hub Type (Order Ampere separately from Rating (Max.) page 1-17) Line Side Main Lugs AWG/ kcmil (Al/Cu) Service Weight Ground Each Lug (Lbs) AWG/ and kcmil Pallet (Al/Cu) Qty.
UL
UL and EUSERC
QO
Surface Mount Only 125 A None OH/UG OH/UG 200 A None OH/UG
10 kA 22 kA 22 kA
OH/UG 10 kA C4L200S 1143.00 Surface Mount Only 125 A None OH/UG OH/UG 10 kA SC8L125S 846.00 4 HOM 200 A None OH/UG OH/UG 10 kA SC12L200S 1419.00 6 HOM Semiflush Mount only 125 A None OH/UG OH/UG 10 kA SC8L125F 846.00 4 HOM None OHd/UG OHd/UG 10 kA SC12L200F 1419.00 6 HOM 200 A None OHd/UG OHd/UG 22 kA SC816F200F e 1187.00 1 QOM2200VHa Surface MountSupplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers OH/UG 22 kA SC816F150S e 1187.00 1 QOM2150VHa 150 A None OH/UG SC816D150Ce f 1 HOM2150a 10 kA 1250.00 HOM UG SU816D150Ce f 1 OH/UG 22 kA SC816F200S e 1187.00 1 QOM2200VHa 200 A None OH/UG SC816D200Cef 1250.00 1 HOM2200a 10 kA UG SU816D200C ef 1250.00 1 HOM Surface Mount Only None 22 kA RC200Si 1022.00 1 QOM2-VH Lever None Horn 200 A Lever OH/UG 10 kA RC2M200SL 2090.00 1 QO-VH 10 kA 22 kA RCM200SL RC2M200Si RC2M200SHi 1950.00 1083.00 1136.00 1 1 1 1 QOM2-VH QOM2-VH QO-VH QOM2-VH
1 1 1 1 2
16 16 16 16 16
8 8 8 8 8
B A A A A AL
41/0 4250 4250 4250 62/0 4250 62/0 4250 4250 4250 6300 4250 6300
81/0 15, 54 (2) 82/0 26, 24 (2) 82/0 27, 20 (2) 82/0 27, 28 62/0 122/0 62/0 122/0 122/0 122/0 121/0 122/0 121/0 31, 24 40, 10 37, 20 47, 10 51, 10 40, 10 48, 18 40, 10 48, 18
125 Ab 200 Am 110 A 200 Aj 200 A 8 150 A 150 A 50 A 200 A 200 A 50 A 200 A 200 A 200 A 50 A 200 A 50 A 200 Aj 200 Aj 100 A 125 A 125 A 150 A 150 A 200 A 200 A 200 A 200 A 8 8 8 8 8 8 8 8 8 8 8 8 8
A A A A A A A 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 100 100 100 150 Ak 150 Ak 150 A 200 Aj 200 Aj 200 A 100 A 100 A 150 Ak 150 Ak 150 A 200 Aj 200 Aj 200 A A A A A A
6350
Ringless
None QC12L200Cg 1562.00 6 QO-VH 22 kA Horn QC12L200CHg h 1883.00 6 QO-VH Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers 100 A Horn OH/UG 22 kA QC816F100CHegh 1356.00 1 QOM2100VHa None OH/UG 22 kA QC816F125Ceg 1304.00 1 QOM2125VHa 125 A Horn OH/UG 22 kA QC816F125CHegh 1356.00 1 QOM2125VHa None OH/UG 22 kA QC816F150Ceg 1304.00 1 QOM2150VHa 1 QOM2150VHa Horn OH/UG 22 kA QC816F150CHegh 1356.00 150 A Lever OH/UG 22 kA QC816F150SL 2690.00 1 QOM2150-VHa None Horn Lever OH/UG OH/UG OH/UG 22 kA 22 kA 22 kA QC816F200Ceg 1356.00 QC816F200CHegh 1356.00 QC816F200SL 2690.00 1 1 1 QOM2200VHa QOM2200VHa QOM2200-VHa
QO
(2)82/0 6350 14-1/0 Cu 12-1/0 Al 6350 (2)82/0 6350 (2)82/0 14-1/0 Cu 12-1/0 Al 6350 14-1/0 Cu 12-1/0 Al 6350 122/0 6350 122/0
122/0
40, 21
200 A
14-2/0 Cu 74 / 12 12-2/0 Al 62/0 6350 6350 62/0 122/0 122/0 27, 32 40, 21 40, 21
Surface Mount Only 125 A None OH/UG 10 kA RC8L125S 846.00 4 HOM 200 A None OH/UG 10 kA RC12L200Cg 1419.00 6 HOM 200 A Horn OH/UG 10 kA RC12L200CHgh 1419.00 6 HOM Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers 100 A Horn OH/UG 22 kA RC816F100CHegh 1227.00 1 QOM2100VHa 125 A Horn OH/UG 22 kA RC816F125CHegh 1227.00 1 QOM2125VHa None OH/UG 22 kA RC816F150Ceg 1187.00 1 QOM2150VHa Horn OH/UG 22 kA RC816F150CHegh 1227.00 1 QOM2150VHa 150 A Lever OH/UG 22 kA RC816F150SL 2690.00 1 QOM2150-VHa None Horn Lever 200 A OH/UG OH/UG OH/UG 22 kA 22 kA 22 kA RC816F200Ceg 1227.00 RC816F200CHegh 1227.00 RC816F200SL 2690.00 1 1 1 QOM2200VHa QOM2200VHa QOM2200-VHa
125 Ab 200 Aj 200 Aj 100 A 125 A 150 A 150 A 200 A 200 A 200 A 200 A 8 8 8 8 8 8 8 8
Homeline
122/0
40, 21
200 A
14-2/0 Cu 72 / 12 12-2/0 Al
a b c d e f g h i
1 Horn OH/UG 10 kA RC816D200CHefho 1292.00 1 Service disconnect supplied factory-installed. 125 A Homeline 2P circuit breaker can be installed in top position only. All other positions are limited to 100 A max. UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed. Suitable for OH service with addition of tunnel kit SCTK20. Order separately. Supplied with load side feed-thru lugs, for 6 AWG250 kcmil (Al/Cu) conductors. Convertible to semiflush with SC200F flange kit (order separately). Device supplied with barrel lock provisions factory-installed. Supplied with horn bypass and 5th jaw factory-installed. 5th jaw factory-installed.
HOM2200 a 200 A 8 16 8 100 Al A or B300 6300 61/0 48, 18 HOM 50 A Use only 15100 A and 150200 A circuit breakers. Use only 15100 A and 150 A circuit breakers. A 100 A circuit breaker can be installed in bottom position only, all other positions are limited to 70 A. m Use only 15110 A and 150200 A breakers. n Use only 15110 A and 150 A breakers. o Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories, page 1-22). j k l
DE3A
Discount Schedule
1-19
LOAD CENTERS
Combination Service Entrance Devices 100 to 225 A Maximum Meter Mains and All-In-Ones Ring or ringless type meter socket designs available UL Listed, suitable only for use as service equipment Meets EUSERC standards
1P 2P Circuits (Max.) Type (Order separately from page 1-22 except as noted) HOM2100 HOM2125 QOM2200VH HOM2200 HOM2200 HOM2100 HOM2125 QOM2125VH QOM2200VH QOM2200VH QOM2200VH QOM2225VH QOM2225VH HOM2100 QOM2200VH QOM2200VH QOM2200VH QOM2200VH QOM2225VH HOM2100 HOM2125 QOM2125VH QOM2150VH QOM2150-VHa QOM2200VH QOM2200VH QOM2200-VHa Ampere Rating (Max.) Circuits Spaces Tandems
Surface Mount Only 100 A None OH/UG 125 A None OH/UG 200 A None OH/UG 200 A None OH/UGf 200 A None UG Semiflush Mount Only 100 A 125 A Homeline Ring Type None None OH/UG OH/UG OHc/UG OHc/UG OHe/UG OHe/UG 10 kA 10 kA 22 kA 10 kA 10 kA 10 kA 10 kA 22 kA 22 kA 22 kA 22 kA SC1624M100S SC1624M125S SC2040M200S SC2040M200C b SU2040M200Cb SC1624M100F SC1624M125F SC2040M125F SC2040M200F SC2636M200FPVd SC3040M200F SC3040M225F SC2636M225FPVd SO1020M100S SO2040M200S SC3040M200S SC40M200S SU3040M200R SU3040M225R 744.00 1518.00 1671.00 1799.00 1799.00 744.00 1518.00 1671.00 1671.00 2244.00 2064.00 2280.00 2520.00 443.00 1161.00 2010.00 2432.00 2223.00 2646.00 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 100 A 125 A 200 A 200 A 200 A 100 A 125 A 125 A 200 A 200 A 200 A 225 A 225 A 100 A 200 A 200 A 200 A 200 A 225 A 100 A 125 A 125 A 150 A 200 A 200 A 200 A 200 A 16 16 20 20 20 16 16 20 20 26 30 30 26 10 20 30 40 24 24 40 40 40 24 24 40 40 36 40 40 36 20 40 40 40 8 8 20 20 20 8 8 20 20 10 10 10 10 10 20 10 0 100 A A 125 Aa 200 Ak A-L 100 A A or A-L 100 A A or A-L 100 A 110 A 110 A 200 Ak 100 A 200 A 200 A 100 A 80 A 200 Aj 200 A 200 A A or B300 A-L 62/0 4250 6300 6300 62/0 62/0 121/0 121/0 32, 24 45, 10 47, 18 47, 18
Ampere Rating
Bypass Type
Homeline
Ringless
QO
1
LOAD CENTERS
Service disconnect(s) are supplied factory-installed, except where noted Semiflush-reverse design available, supplied with load center (indoor access) Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. Meets Federal Specification W-P-115c as Type 1, Class 2
Table 1.53:
62/0 4250
62/0 122/0
44, 20 51, 10
200 A
None
A-L
4250
122/0
56, 10
225 A
None
Surface Mount Only 100 A 200 A 200 A None None None OHf OHf OH/UG 10 kA 22 kA 22 kA A A A-L 61 6350 4250 4250 144 82/0 122/0 122/0 20, 42 43, 21 50, 10 52, 10
REVERSE All-In-OneSemiflush Mount with Service Disconnect (outdoor access) and Load Center (indoor access) 200 A 225 A 100 A 125 A 125 A 150 A None None UG UG 10 kA 10 kA 30 40 10 200 A A or B300 6300 121/0 60, 15
Surface Mount Only None Horn Horn Lever None Horn Lever OH/UGf OH/UGf OH/UGf OH/UG OH/UGf OH/UGf OH/UG 10 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA RC1624M100S 744.00 RC1624M125S 1518.00 RC2040M125CHgh 1601.00 RC2040M150CHgh 1713.00 RC3040M150SL 4900.00 16 20 20 30 20 20 30 24 40 40 40 40 40 40 8 20 20 10 20 20 10 100 A 125 Aa 100 A 150 Ai 150 A 200 Aj 200 Aj 200 A A 6350 62/0 62/0 122/0 32, 24 40, 21
200 A
14-2/0 Cu 76 / 12 12-2/0 Al
Surface Mount Only Horn OH/UGf 22 kA QC2442M150CHgh 1905.00 1 None OH/UGf 22 kA QC2442M200Cg 1905.00 1 Horn OH/UGf 22 kA QC2442M200CHgh 1905.00 1 125 A Homeline 2P circuit breaker can be installed in top position only. All other positions are limited to 100 A max. Convertible to semiflush with SC200F flange kit (order separately). Suitable for OH service with addition of tunnel kit (SCTK20). Order separately. For use with Photovoltaic Systems. Provisions for field-installed CT. If required by adopted code, order retaining kit PK2SCPV separately. See page 1-22. Suitable for OH service with addition of tunnel kit (SCTK30). Order separately. Device does not meet EUSERC Specifications. 200 A 150 A QOM2150VH 150 A 24 42 18 150 Ai QOM2200VH 200 A 24 42 18 200 Aj A QOM2200VH 200 A 24 42 18 200 Aj g Device supplied with barrel lock provisions factory-installed. h Supplied with horn bypass and 5th jaw factory-installed. i Use only 15100 A and 150 A circuit breakers. j Use only 15100 A and 150200 A circuit breakers. k Use only 15110 A and 150200 A circuit breakers. 6350 82/0 40, 21
a b c d e f
1-20
DE3A
Discount Schedule
Ring or ringless type meter socket designs available UL Listed, suitable only for use as service equipment Meets EUSERC standards
Service disconnects are supplied factory-installed, except where noted Supplied with 100% branch neutrals; all unused terminals may be used for equipment grounding wires Meets Federal Specification W-P-115c as Type 1, Class 2 LOAD CENTERS
Table 1.54:
Meter Mains
Load Center and Branch Circuit Breakers (Order Separately Pages 1-2, 1-3, 1-14) Max. Quantity 1P Type 2P separately Circuits (Orderpage 1-22 from (Max.) except as noted) Ampere Rating (Max.) Circuits Spaces Ampere Rating (Max.)
Meets Federal Specification W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 13W, NEMA 3R Enclosure
Service Disconnect(s) a Short Circuit Current Rating Cat. No. List $ Price
Ampere Rating
Bypass Type
Service Weight Ground Each Lug (Lbs) AWG/ and kcmil Pallet (Al/Cu) Qty.
UL and UL EUSERC
Tandems
Surface and Semiflush Mount b CU12L400CN c 400 A None UG UG 25 kA CU12L400FN c CU12L400CB ck 25 kA CU12L400FB ck CU816D400CN ci CU816D400FN ci CU816D400CB cik CU816D400FB cik CUM400CB ck 3810.00 4007.00 3986.00 4182.00 3975.00 4172.00 4151.00 4347.00 8688.00 1 1 4 1 1 4 1 1 1 1 1 1 UG 25 kA QU12L400SL gk 3810.00 1 4 QDL22200 d QDL, QGL, QJLe QOH QDL22200 d QDL, QGL, QJLe QOH QDL22200 d QDL, QGL, QJLe QDL22200 d QDL, QGL, QJLe DGP36400E20LHd QDL22200 d QDL, QGL, QJLe QOH 200 A 200 A 125 A h 200 A 200 A 125 A h 200 A 200 A 200 A 200 A 400 A 200 A 200 A 125 A h 8 8 16 16 8 8 200 A 200 A AL (2) Studs 4250 98, 4
Ring Type
400 A
AL
(2) Studs
4250
98, 4
400 A
UG
25 kA 25 kA
AL AL
4250 4250
98, 4 98, 4
Class 320 400 A Manual UG Bypass Class 320 400 Af Manual UG Bypass QO 400 A Class 320 Lever
65 kAa
2f
200 A
AL
(2) Studs
4250
115, 4
AL
(2) Studs
4250
98, 4
Surface Mount Only, Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers 400 A Ringless Type l UG 25 kA QU816D400SLigk QU816D400CK ik 4065.00 1 1 QDL22200 d QDL, QGL, QJLe 200 A 200 A 8 16 8 200 A AL (2) Studs 4250 98, 4
Surface and Semiflush Mount b 400 A Class 320 Lever 400 A UG 25 kA 65 kAa 65kAa UG 25 kA QU12L400CLgjk QU12L400FLgjk QU816D400CLgjik QU816D400FLgjik QUM400CLck QUM400CKck 3810.00 4007.00 4065.00 4262.00 10000.00 11175.00 1 1 4 1 1 1 1 QDL22200 d QDL, QGL, QJLe QOH QDL22200 d QDL, QGL, QJLe DGP36400E20LHd DGP36400E20LHd 200 A 200 A 125 A h 200 A 200 A 400 A 400 A 8 16 8 200 A 200 A 200 A AL (2) Studs 4250 98, 4
AL AL AL
2f 2f
Table 1.55:
Surface and Semiflush Mount b 300 A Ring Type 300 A Homeline 400 A 400 A None UG UG UG 25 kA 25 kA 25 kA 25 kA 25 kA 25 kA SU3040D300CN cj SU3040D300CB cjk SU3040D300FB cjk SU3040D400CN cj SU3040D400FN cj SU3040D400CBcjk SU3040D400FB cjk RU3040D400CL gjk RU3040D400FL gjk RU3040D400CK jk RU3040D400FK jk 6600.00 6600.00 6797.00 7050.00 7247.00 7167.00 7364.00 6993.00 7190.00 6993.00 7190.00 1 1 1 1 1 1 1 1 1 1 1 1 QDL22200 d QDL, QGL, QJL e QDL22200 d QDL, QGL, QJLe QDL22200 d QDL, QGL, QJLe QDL22200 d QDL, QGL, QJLe QDL22200 d QDL, QGL, QJLe QDL22200 d QDL, QGL, QJLe f 200 A 100 A 200 A 100 A 200 A 200 A 200 A 200 A 200 A 200 A 200 A 200 A 30 30 30 30 30 30 40 40 40 40 40 40 10 10 10 10 10 10 200 A 200 A 200 A 200 A 200 A 200 A AL AL AL AL AL AL (2) Studs (2) Studs (2) Studs (2) Studs (2) Studs (2) Studs 4250 4250 4250 4250 4250 4250 100, 4 100, 4 100, 4 100, 4 100, 4 100, 4
Ringless
a b c d e
UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed. For 400 A device with suffix CB, CK, CL, or CN, surface-mount convertible to semiflush with FK400 flange kit (order kit separately). Devices wtih suffix FB, FL, FN or FK are semiflush only, with the top endwall factory-installed and flanges factory-included. For use only on 120/240 Vac 13W system (4-jaw meter socket). Service disconnect supplied factory-installed. Additional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25 kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker catalog number, see Section 7.
g h i j k l
Option for field installation of two Q-frame, 200 A max. 2-pole branch circuit breakers used as mains for two downstream load centers. Purchase installation kit BMK2Q400 and two Q-frame circuit breakers separately. Order QBL prefix at 10 kA, QDL prefix at 25 kA, or QGL prefix at 65 kA. Fifth jaw factory-installed. QO panel is rated 200 A maximum. Supplied with load side feed-thru lugs for 6 AWG250 kcmil (Al/Cu) conductors. Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories, page 122). Device configuration is not included in EUSERC standards. Consult applicable utility for acceptance. Device with suffix L has Class 320 lever bypass and device with suffix K has a K-4 bolt-on, no bypass.
1-21
Table 1.56:
Ampere Rating a 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200
Circuit Breakers for use with Meter Mains and All-In-One Devices
Type: HOM, 1P Cat. No. (DE3D) HOM115 HOM120 HOM125 HOM130 HOM140 HOM150 $ Price 26.30 26.30 26.30 26.30 26.30 26.30 Type: HOM, 2P Cat. No. (DE3D) HOM230 HOM235 HOM240 HOM245 HOM250 HOM260 HOM270 HOM280 HOM290 HOM2100 HOM2110 HOM2125 HOM2150BB HOM2175BB HOM2200BB $ Price 60.00 60.00 60.00 60.00 60.00 60.00 123.00 168.00 168.00 168.00 369.00 369.00 428.00 428.00 428.00 Type: QO, 1P Cat. No. (DE2A) QO110 QO115 QO120 QO125 QO130 QO135 QO140 QO145 QO150 QO160 QO170 $ Price 29.10 29.10 29.10 29.10 29.10 29.10 29.10 29.10 29.10 29.10 67.00 Type: QO, 2P Cat. No. (DE2A) QO230 QO235 QO240 QO245 QO250 QO260 QO270 QO280 QO290 QO2100 QO2110 QO2125 QO2150 QO2175 QO2200 $ Price 67.00 67.00 67.00 67.00 67.00 67.00 134.00 189.00 189.00 189.00 428.00 428.00 491.00 491.00 491.00 Type: QO-VH, 1P Cat. No. (DE2A) QO115VH QO120VH QO125VH QO130VH $ Price 63.00 63.00 73.00 73.00 Type: QO-VH, 2P Cat. No. (DE2A) QO230VH QO240VH QO250VH QO260VH QO270VH QO280VH QO290VH QO2100VH QO2110VH QO2125VH QO2150VH QO2175VH QO2200VH $ Price 146.00 146.00 146.00 146.00 224.00 315.00 315.00 315.00 1034.00 1034.00 1061.00 1061.00 1061.00
1
LOAD CENTERS
Type: QOM1-VH, 2P Type: QOM2-VH, 2P Ampere Rating Cat. No. (DE3D) $ Price Cat. No. (DE3D) $ Price a 50 QOM50VHb 140.00 60 QOM60VH 140.00 70 QOM70VH 140.00 80 QOM80VH 201.00 90 QOM90VH 201.00 100 QOM100VH 201.00 QOM2100VH 468.00 110 QOM110VH 468.00 125 QOM125VH 468.00 QOM2125VH 468.00 150 QOM2150VH 468.00 175 QOM2175VH 468.00 200 QOM2200VH 468.00 225 QOM2225VH 468.00 a Do not exceed mains rating of device b Reference National Electrical Code Article 230-79. c For additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA.
Type: QDL, 2Pc Cat. No. (DE2A) QDL22070 QDL22080 QDL22090 QDL22100 QDL22110 QDL22125 QDL22150 QDL22175 QDL22200 $ Price 1143.00 1143.00 1143.00 1143.00 1143.00 1143.00 1143.00 1143.00 1143.00
Table 1.57:
Accessories
Description Generator Kit: Interlocks main service disconnect and generator circuit breaker (order separately). For : Homeline CSED Devices RC816F-, RC2040M-, SO2040M QO CSED Devices QC816F-, QC2442MBackfed inverter circuit breaker retaining kit for SC2636M200FPV and SC2636M225FPV Meter Main Types: C, RC, SC, QC Fifth Jaw Kit for: All-In-One Types: SC, SU (100225 A), QC, RC, SO Bypass (Horn Type) for Ringless Type Meter Mains and All-In-Ones (100200 A) (except for RC8L125S, RC1624M100S and RC1624M125Suse RCHB). Lexan Meter Socket Cover Plate for:
Ring and Ringless Type Meter Mains Ring and Ringless Type All-In-Ones
29007
10.10
DE4
Meter Socket Sealing Rings for Ring Type Meter Mains and All-In Ones: Snap Type Aluminum (Std.) Screw Type Aluminum Snap Type Stainless Steel Anti-Inversion Kit . For use ONLY on 400 A Meter Mains and All-In-Ones with lever bypass. Trim Kit for 2 in. X 6 in. stud wall, used with Reverse All-In-Ones, SU3040M200R, and SU3040M225R Barrel Lock Kit (Barrel Lock not included), supplied with bracket and mounting screw, refer to listings for where used. Semiflush Flange Kit for: Meter Mains: SC816D150/200C and RC816D200CH All-In-Ones: SC2040M200C Semiflush Flange Kit for ring- and ringless-type Meter Mains and All-In-Ones (400 A Only) Ringless Type Utility Cover for RU3040D400CL/FL, QU12L400CL/FL, and QU816D400CL/FL. Includes one piece meter socket and pull box cover with handles and closing plate. Lug Kit includes (4) lugs, for use with 2 AWG600 kcmil Al/Cu conductors. Lugs are for standard 2-Hole mounting. Meter Main and All-In-One units supplied with (2) studs per phase and neutral will accept one lug per phase and neutral. Not for use on 400 A devices with K suffix. Branch Circuit Breaker Field Installation Kit for two Q-Frame Circuit Breakers (QBL, QDL, or QGL, order separately). For CUM400CB, QUM400CL or QUM400CK - includes (2) mounting pans, (4) wires. Overhead Feed Trough for 400 A ring- and ringless-type Meter Mains and All-In-Ones. Touch-Up Paint (ASA49 Gray) Ground Bar Kit, Meter Mains and All-In-Ones QC, RC, and SC (100225 A) Filler Plate for: Meter Main Types: QC, CU All-In-One Types: QC Filler Plate for: Meter Main Types: RC, SC All-In-One Types: SC, RC, SU Neutral Lug (6-2/0 AWG) Meter Main Types: RC, SC, QC All-In-One Types: SC, SU, QC, RC for:
2920910001 29008W ARP00026 MMLRK SU2X6TRIM SCBRLLOCK SC200F FK400 R400L CMELK4 BMK2Q400 OCK400 PK49SP PK15GTA QOFP HOMFP LK100AN
7.95 20.10 16.70 12.00 266.00 53.00 31.80 197.00 266.00 137.00 153.00 567.00 39.00 17.10 3.60 3.20 10.80
DE5 DE4 DE4 DE4 DE4 DE4 DE4 DE4 DE4 DE4 DE4 DE4 DE1 DE3A DE3A DE3A DE3A
Closing Plate for A-L Hub ACPL 18.30 opening 2.00 A200L d 83.00 2.50 A250L 87.00 A-L 3.00 A300L 111.00 3.50 A350L 114.00 4.00 A400L 119.00 Closing Plate for B Hub opening BCAP 3.80 0.75 B075 33.30 1.00 B100 33.30 1.25 B125 33.30 B 1.50 B150 33.30 2.00 B200 61.35 2.50 B250 102.00 B300 3.00 B300 186.00 d Supplied with AAP adapter plate and A hub.
1-22
DE1
DE1A
DE2A
DE3A
DE3D
DE4
DE5
Discount Schedule
Dimensions
Class 4119, 4120
a
14.97
380
A Hub
28.28 7.14
181 718
C,D,F
B,C,D A
b
7.50
191
B Hub
A Hub
4.60
117
4.60
117
4.56
116
7.50
191
13.82
351
19.58
497
13.46
342
28.25
718
7.44
189
12.80
325
10.70
272
6.44
164
8.00
203
18.23
463
528
A,B
C,D,E,F
A,B
41.25
1048
A,B
SO1020M100S
21/2" Max A Hub
A G,H,I,J A-L Hub C,D,F B,C
4.67
119
4.80
122
Surface
3.39
86
14.37
365
14.77
375
14.50
368
10.04
255
10.87
276
10.87
276
35.13
25.12
638
892
CU12L400CNc CU12L400CBc QU12L400CLc QU12L400SL CU12L400FNf CU12L400FBf CU816D400FNf CU816D400FBf QU816D400CKc QU12L400FLf QU816D400FLf
6.95
176
25.12
638
14.50
368
A 21/2" Max A Hub D,F,G C,D,F A,B B,C A D,F,G 21/2" Max A Hub or B300 C,D,E,F A,B B,C
14.81
376
D,E,F,G
A,B A,B,C
32.23
819
C,D,E,F
C,D,F
A,B
3.40
86
B,C A,B
14.62
371
7.90
201
B,C
14.85
377
B,C
7.50
C L Top Branch Circuit Breaker
191
28.25
718
31.61
803
27.00
686
35.40
899
39.60
1006
8.00
203
5.80
147
48.00
1219
21.50
546
SC3040M200S
C L Meter Socket
10.30
262
41.25
1048
11.10
282
B
SC40M200S
29.50
749
32.30
820
A B C,D
4.40 3.50
89 112
C,D,E,F
37.30
A G,H,I,J A-L Hub C,D,E,F C,D,F B,C A B,C C,E,F,G,H 21/2" Max A-L Hub B
947
35.40
899
39.60
1006
SU3040D400CBc (Shown) SU3040D300CBc RU3040D400CLc SU3040D400CNc RU3040D400CKc RU3040D400FLf SU3040D300FBf RU3040D400FK f SU3040D400FBf CUM400CB c SU3040D400FNf QUM400CL c QUM400CK c
1-23
20.79
LOAD CENTERS
Drip Hood
Driphood supplied factory-installed and is required for surface mount installation. For semi-flush installation, remove driphood and install flange kit SC200F (order separately). Unit supplied with blank top endwall (factoryinstalled) for surface mount installation. For semiflush installation, install flange kit FK400 (order separately). Kit includes replacement top endwall (with knockouts) and flanges. Unit supplied with semi-flush top endwall factory installed and semi-flush flanges factory included.
Table 1.58:
Symbol Conduit Size (in.) A 1/2
Knockouts
B 3/4 C 1 D E F 2 G 2-1/2 H 3 I 3-1/2 J 4
1-1/4 1-1/2
Enclosed Devices
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
LOAD CENTERS
Service
Service
240 Vac
120/240 Vac
50 A
120/240 Vac
100 Ad
QO2000NS
276.00 QO2000NRB
Table 1.60:
Housing Bracket
Cat. No. PKHB $ Price 6.30
Description Bracket used with QO200TR for stucco, aluminum and vinyl siding. Order quantity multiples of 10.
120/240 Vac
240 Vac
100 A
QO3100BNF/S
149.00 QO3100BNRB
207.00
13, 10R
Table 1.63:
QO200TRNM QO3100BNF With Cover Removed PKHB Housing Bracket
Circuit breaker not included. Order separately from page 1-2. Will not accept QO-GFI circuit breaker nor QO circuit breakers with factory-installed accessories. 240 Vac 60 A a QO2TR 95.00 9R c
Table 1.64:
Service
Q22200NS h or Q23225NF/S
380.00 417.00
3P 240 Vac
Q23225NF/S
218.00
Q23225NRB
278.00
20, 12R
Table 1.65:
Q23225NF
100 A QOM2100VH 468.00 125 A QOM2125VH 468.00 150 A QOM2150VH 468.00 QOM22225NF/S 234.00 QOM22225NRB 440.00 22, 16R 175 A QOM2175VH 468.00 2P 240 Vac Maximum 200 A QOM2200VH 468.00 225 A QOM2225VH 468.00 a Not suitable for service equipment. h Accepts 200 A max. 2P Q Frame circuit breakers. b Maximum 10 hp 240 Vac. i Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126. c Top endwall has no hub opening. j When these 3P circuit breakers are mounted in d Maximum 20 hp 240 Vac. an enclosure, the maximum AIR rating is 65 kA at e Order F for flush, S for surface. 240 Vac and 100 kA at 208 Vac. f Equipment ground bar kit PKOGTA2 k DE3A Discount Schedule. factory-included. g Factory-installed groundable neutral assembly includes (2) ground lugs and (2) neutral lugs. Equipment ground kit PKOGTA2 also included.
1-24
DE2A
DE3A
Discount Schedule
For Construction Sites Provide temporary power at construction sites. Each receptacle protected by QO-GFI circuit breaker in compliance with NEC
LOAD CENTERS
$ Price 441.00 818.00 818.00 974.00 974.00 974.00 974.00 1323.00 1323.00 Main Wire Size AWG d Cu 146 146 146 81 81 81 81 81 81 141 Al 126 126 126 81 81 81 81 81 81 121 Main Wire Size AWG/kcmil f Cat. No. $ Price Phase and Neutral Cu 470.00 795.00 564.00 654.00 141 669.00 121 Al 146 126
1C
T T
2C
T T T
3C
T
requirements. Each enclosure is rainproof. 10 kA short circuit current rating. UL Listed as suitable for use as temporary site service equipment. Provided with neutral bonding provisions. Boxes have provisions for type B hubs to be field-installed. Construction Site Panels
Service a 12W 12W 12W 13W 13W 13W 13W 13W 13W 13W Mains Ampere Rating 40 A 40 A 40 A 70 A 70 A 70 A 70 A 70 A 70 A 100 A Circuit Breaker (Included) (1) QO120GFI (2) QO120GFI (2) QO120GFI (1) QO120GFI (1) QO230GFI (1) QO120GFI (1) QO220GFI (1) QO120GFI (1) QO250GFI (1) QO120GFI (1) QO250GFI (2) QO120GFI (1) QO220GFI (2) QO120GFI (1) QO250GFI (1) QO120GFI (2) QO250GFI Receptacles (Included) A 1 2 2 1 1 1 1 2 2 1 1 2 1 1 1 1 C D E F PAK10C1 PAK11Ce PAK11C1 1 PAK31CGFI PAK36C1GFI PAK51CGFI PAK55CGFI PAK72CGFI PAK76CGFI Cat. No. c
Table 1.66:
4C 5C 6C
Power Outlet Configuration
T T T
1C 2C 2C 3C 4C
7C
T
8C
T T
9C
T
5C 6C 7C
10C
11C
12C
8C 9C
PAK1004CGFI 1581.00
13C
14C
A
B C D E F
20 A 125 V 2W and Grd. NEMA 5-20R 30 A 125 V 2W and Grd ANSI 73.13 50 A 125/250 V 3W and Grd. NEMA 14-50R 20 A 250 V 2W and Grd. NEMA 6-20R 30 A 125/250 V 3W and Grd. NEMA 14-30R 50 A 250 V 2W and Grd. NEMA 6-50R
For Recreational Vehicle Parks Provide electrical power to individual recreational vehicle park sites. Each receptacle protected by appropriate GFI or Standard QO circuit breaker. All receptacles and circuit breakers included. 10 kA short circuit current rating. UL Listed. All enclosures are rainproof. No neutral bonding provisions. Loop-feed provisions.
Table 1.67: Recreational Vehicle Park Panels
Receptacles (Included) b A B C
Mains Power Outlet Service Ampere Circuit Breaker Configuration a (Included) Rating
All non-pedestal devices have provisions to fieldinstall a Type B hub on the bottom endwall for bottom feed from a conduit riser. Order Type B bolt-on hub (B250 Max.) and two mounting screws (Cat. No. 8002505501) and two hex nuts (Cat. No. 2340102000).
Underground or Overhead Loop-Feed TerminalsNon-Pedestal cg 10C 12W 40 A (1) QO120GFI 1 PAK10CTG 11C 12W 40 A (2) QO120GFI 2 PAK11CTG QO120GFI 12C 12W 50 A (1) QO130 1 1 PAK41CTG h (1) QO120GFI 13C 12W 75 A (1) QO130 1 2 PAK61CTG h (2) (1) QO120GFI PAK75CTG 14C 13W 100 A (1) QO250 1 1 1 (Not Loop Feed) h (1) QO130
Pedestal MountedUnderground Loop-Feed Terminals ij 11C 12W 40 A (2) QO120GFI 2 PAK11PG 1035.00 QO120GFI 12C 12W 50 A (1) QO130 1 1 PAK41PG h 852.00 (1) (1) QO120GFI 13C 12W 75 A (2) QO130 1 2 PAK61PG h 914.00 (2)6250 (2)6250 (1) QO120GFI 14C 13W 100 A (1) QO250 1 1 1 PAK75PG h 1007.00 (1) QO130 a (12W 120 Vac) (13W 120/240 Vac) b 20 A receptacles protected by 20 A GFI circuit breaker. c Devices have a bolt-on factory-installed closing cap. Order type "B bolt-on hub separately from page 1-18. d Equipment ground terminal suitable for (2) 14 or 12 AWG Cu or (2) 12 or 10 AWG Al. e Receptacles in this device are in bottom endwall and are accessible with outer door padlocked. "Order Only from LexingtonMinimum order quantity is 50 devices. f Two wires each per phase, neutral, and equipment groundfor loop feed (except PAK75CTG). g Equipment ground terminal suitable for (2) 1412 AWG Cu or (2) 1210 Al. h GFI circuit breaker can be substituted for standard 30 A circuit breaker. For 30 ampere receptacles add $140.00 per circuit breaker. Add suffix "FI to catalog number. Example: PAK41CTGFI. i Stabilizer foot available for use in unstable ground, order HNPSF $27.50 list. j Equipment ground terminals suitable for (2) 102/0 AWG Cu or (2) 62/0 AWG Al.
DE4
Discount Schedule
1-25
1
0.28 7 Dia. 2.50 64 Hub Maximum 1.25 32 0.28 Dia. 7 (3 Holes) 2.50 Hub Maximum 64
LOAD CENTERS
0.17 4 0.18 R 5 0.28 Dia. 7 (3 Holes) 1.26 32 14.21 361 D, E, F, G Knockout or 2.50 Hub Maximum 64 (2) #6 AWG250 kcmil per phase and neutral (2) #102/0 AWG Cu (2) #62/0 AWG Al Equipment Grounding Lugs
Final Grade
9.40 239
6.25 159 2.26 3.24 82 57 1.00 25 D, E, F, G Knockout or 2.50 Hub Maximum 64 2.75 70 7.75 197
PAK10C1 PAK11C1
8.50 216 A, B, C
3.75 95 0.96 24
4.90 124
PAK11C
4.00 102
6.25 159
3.24 2.26 82 57
16.43 417
A, B, C
14.21 361
5.80 3.75 4.63 147 118 95 0.96 24
16.43 417
2.26 3.24 57 82
A, B, C
7.75 197
2.75 70
D, E, F, G Knockout or 2.50 Hub Maximum 64 2.75 70 7.75 197 PAK61CTG PAK61CTGFI PAK75CTG PAK75CTGFI
5.80 7.60 147 193
5.80 7.60 147 193 8.63 219 34.50 876 19.63 499 59.50 1511
(2) #6 AWG250 kcmil per phase and neutral (2) #102/0 AWG Cu (2) #62/0 AWG Al Equipment Grounding Lugs
6.25 159
18.50 470
25.00 635
6.25 159
3.50 89
Final Grade
18.50 470
25.00 635
3.50 89
Detail A
PAK11PG PAK41PG PAK41PGFI PAK61PG PAK61PGFI PAK75PG PAK75PGFI
Detail A
1-26
Table of Contents
Section 2
Metering Equipment
Meter Sockets
Ring and Ringless Type Individual Meter Sockets Horizontal Ganged, Test Block Bypass Sockets and Accessories Dimensions 2-2 2-3 2-4
Ring and Ringless Devices Tenant Circuit Breakers and Accessories Dimensions
2-9
Main Devices Branch Devices EZM Main Devices EZ Meter-Pak Meter Centers and Accessories Dimensions
2-1
Meter Sockets
Available single or three phase, 600 Vac max., with and without horn or lever bypass, overhead and underground service feed. 10 kA short circuit current rating (or higher with utility approval). UL Listed, NEMA 3R enclosure. Units supplied with bonded neutral. Units supplied with hub opening in top endwall require the use of a bolt-on hub, or closing plate. Units supplied with solid top are for underground feed only. Accessories, refer to page 2-3. This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Field Sales Office for additional catalog numbers, if required by utility. Table 2.1:
UTRS101B
Ampere Jaw Ratingj Qty.
Ringless Type, 13W 600 Vac Max., Without Bypass or Jaw Release
125 125 125 125 125 200 200 200 200 200 200 125 125 125 125 200 200 200 200 200 200 200 200 200 200 320 200 320 4 4 4 4 5 4 4 4 4 4 4 4 5 4 5 4 4 4 4 4 4 4 4 5 5 4 7 7 UG OH OH OH OH/UG OH OH UG OH/UG OH/UG OH/UG OH/UG OH OH OH/UG OH/UG OH OH/UG OH/UG UG UG OH OH/UG OH OH/UG OH/UG OH/UG OH UTZRS101Ad UTRS101B UATRS101B URS101BCPL 1003880Ae UTRS202B UATRS202B UTRS213Ad UTRS213Be UATRS213Be U92197CCCPLg UHTRS101B UGHTRS101Lc URS101BDQh UGHTRS111Cf UBHMRS212Be UHTRS202B UHTRS212Be UHTRS213Be UHTRS223Ad URS212ADQdh UTH4203T UTH4213Te UTH5203T UTH5213Te UTH4330Tei UTH7213Te UTH7300Ti 123.00 123.00 137.00 135.00 161.00 177.00 195.00 212.00 212.00 225.00 240.00 161.00 161.00 138.00 207.00 210.00 206.00 206.00 213.00 272.00 203.00 465.00 479.00 494.00 564.00 749.00 666.00 830.00 82/0 82/0 82/0 82/0 82/0 8250 8250 1/0350 1/0350 1/0350 1/0350 82/0 82/0 82/0 82/0 8250 8250 8250 1/0350 1/0350 8250 6350 6350 6350 6350 Studs Only 6350 Studs Only 1/2 in. Hex Slotted Slotted Slotted Slotted 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex Slotted Slotted 1/2 in. Hex Slotted 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 1/2 in. Hex 3/8 in. dia. studs 1/2 in. Hex 3/8 in. dia. studs 1/2 in.20 dia. studs 1/2 in.20 dia. studs 142 142 142 142 142 142 142 142 142 142 142 142 142 None 142 None 142 142 142 142 None 142 142 142 142 141/0 142 141/0 1/2 in.20 dia. studs 1/2 in.20 dia. studs Steel Steel Aluminum Steel Steel Steel Aluminum Steel Steel Aluminum Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel 1R 1R 1R 1R 1R 3R 3R 5R 5R 5R 7R 1R 1R 1R 4R 4R 3R 4R 5R 2R 4R 8R 9R 8R 9R 11R 9R 10R
2
METERING EQUIPMENT UTRS202B (cover not shown) UTH5203T (cover not shown) URTRS213B
Ringless Type, 13W 600 Vac Max., With Horn Bypass, Without Jaw Release
Ringless Type, 13W 600 Vac Max., With Lever Bypass and Jaw Release
Ringless Type, 34W 600 Vac Max., With Lever Bypass and Jaw Release Ringless Type, 34W 600 Vac Max., Bolt-On Socket Without Bypass
400 400 7 7 OH/UG OH/UG UK7T ei UAK7Tei 2423.00 2678.00 Studs Only Studs Only Steel Aluminum Series A-L Series A-L ACPL ACPLA 12R 12R
Ring Type, 13W 600 Vac Max., Without Bypass or Jaw Release
125 4 OH/UG URTRS101Be 123.00 82/0 Slotted 142 Steel Series A ACP 1R 200 4 OH/UG URTRS213Be 212.00 1/0350 1/2 in. Hex 142 Steel Series A ACP 5R a Device requires approval from the serving utility, consult your nearest Square D/Schneider Electric sales office. b Order appropriate bolt-on hub or closing plate separately and install on TOP endwall. c Device supplied with 1-1/4 in. bolt-on hub (Cat.No. A125) mounted on TOP endwall. d Device supplied with solid top endwall (without hub opening). e When unit is installed for underground feed, the appropriate closing plate must be ordered separately and installed over hub opening in TOP endwall of device. f Device supplied with closing plate ACP mounted on TOP endwall. g Device supplied with two closing plates ACP mounted in TOP endwall. h Contains Duquesne Light Co. approved label. i Order lugs separately, refer to accessories, page 2-3. j Rating is continuous.
2-2
DE4
Discount Schedule
Meter Sockets
www.schneider-electric.us
UT2R1121B
1, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without horn or lever bypass, end or center feed, overhead and underground service feeds. 10 kA short circuit current rating (or higher with utility approval). UL Listed, NEMA 3R enclosure. Supplied with ground lugs. Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate.
This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Field Sales Office for additional catalog numbers, if required by utility. Table 2.2: Ringless Type, 13W, 600 Vac Max., Without Bypass or Jaw Release
Mains Rating (A) 200 205 205 250 300 205 360 500 620 Cat. No. $ Price Main Lugs Phase and Neutral Al/Cu (AWG/kcmil) 6250 6250 6350 6350 6350 6250 1/0500 1/0500 or (2)1/0350 1/0500 or (2)1/0350 Branch Lugs Phase and Neutral Al/Cu (AWG) Top Endwalla Hub Type Closing Plate Box No. See Page 2-4 (Order (Order Separately) Separately) 13R 13R1 14R 15R 16R 17R 18R 19R 20R
Branch Ratings Socket Service No. of Amperesc Positions Jaw Type Qty.b 2 3 4 5 6 2 4 5 6 a b c
100 A
OH/UG
82/0
Series A
ACP
200 A
OH/UG
For hubs and closing plates, see Accessories table below. Fifth jaw kit available to convert 4-jaw socket to a 5-jaw socket. See Accessories table below. Rating is continuous.
EMT3225CB
d e f g
Table 2.4:
Line Phase Lug Line Neutral Lug Service Ground Lug 6 AWG300 kcmil Al/Cu 6 AWG350 kcmil Al/Cu 4 AWG300 kcmil Al/Cu h Refer to circuit breaker listings for usable load lug wire sizes.
Lug Kits
DE4
DE1A
Discount Schedule
2-3
METERING EQUIPMENT
Meter Sockets
Dimensions
Class 4131
www.schneider-electric.us
D Meter Socket
Hub Opening
Table 2.6:
Enclosure Dimensions
Dimensions (Inches)
A,B,C,D,E S
E,F,G
F,G,H
C,D,E,F,G S A A
1R
D Meter Socket C,D,E,F,G S A H W Hub Opening Meter Socket Offset
2R
Hub Opening D
3R, 6R
W
Hub Opening
Meter Socket
H
D,E,F,G S A
A,B
S
F,G,H
A,B A F,G,H
D,E,F,G
4R, 5R
D W
F,G,H
7R
Hub Opening
Meter Socket F,G,H S H D W Hub Opening Meter Socket Offset F,G,H,I A S H
8R
D W
Hub Opening
Box Hub Opening H W D No. (Max. Conduit Size) a 1R 10.88 8.00 3.50 Series A 2R 13.00 13.00 4.94 Solid Top 3R 14.00 8.00 4.38 Series A 4R 14.00 11.00 4.38 Series A 5R 15.00 11.00 4.38 Series A 6R 15.50 8.00 4.36 Series A 7R 17.13 13.00 4.94 (2) Series A 8R 19.00 10.50 4.94 Series A-L 9R 19.00 13.00 4.94 Series A-L 10R 34.50 15.00 5.68 Series A-L 11R 36.62 15.00 5.68 Series A-L 12R 43.00 20.25 6.00 Series A-L 13R 14.12 24.31 4.50 Series A 13R1 14.12 32.50 4.50 Series A 14R 14.12 40.62 4.50 Series A 15R 14.12 48.75 4.50 Series A 16R 14.12 57.00 4.50 Series A 17R 14.12 24.31 5.38 Series A 18R 14.12 40.62 5.38 Series A-L 19R 14.12 54.75 5.38 (2) Series A-L 20R 14.12 63.00 5.38 (2) Series A-L aRefer to page 2-3 for closing plates and hubs.
2
METERING EQUIPMENT
Meter Socket A,B
Meter Socket
Table 2.7:
F,G,H,I
A
Knockout Information
Knockouts A 1/2 B 3/4 C 1 D E F 2 G 2-1/2 H 3 I 3-1/2 J 4
H
Symbol S Conduit 5/16 Size (in.) b
A,B
1-1/4 1-1/2
F,G,H
F,G,H,I
F,G,H,I
9R
10R
11R
Hub Opening
Hub Opening D W
Hub Opening
Meter Socket
G,H,I,J
Main Lugs S A
Meter Socket
Main Lugs S A
A,B
12R
Hub Opening D W
Hub Opening
Meter Socket
D Main Lugs S A H
C,D,E,F,G
C,D,E,F,G
13R1
C,D,E,F,G C,D,E,F,G C,D,E,F,G
7.50
191
22.44
570
Supplied with (2) ACP Closing Plates. Order A-Hubs separately for overhead service feed.
30.00
762 C,D,E (3 Locations) E,F,G,H (8 Locations) C,D,E,F,G (19R, 20R) A,B
Main Lugs S A
2-4
MP44125
Consult local utility for approval before installation. 120/240 Vac 13W. Main lugs onlytwo to six meter sockets. Enclosures are indoor/rainproof NEMA 3R construction. Suitable only for use as service equipment. Swingable mounting feet supplied at bottom of device. Factory-installed mechanical lugs, alternate lugs and NEMA/EUSERC lug landing kits available. Surface mount, convertible to semi-flush with field installed flange kit. Ring type devices supplied with 4-jaw meter sockets (5th jaw kits available, order separately). Ringless type devices supplied with 5-jaw meter sockets, available with and without horn or lever bypass. Provisions for mounting 2-pole circuit breaker for each meter socket position (order circuit breakers separately). Mounting channel supplied, except for box 1R (125 A, 2-position). Combination overhead/underground feed.
Table 2.8:
Ring Type MP Meter-Pak Metering Equipment with 125 A (42 kA Maximum SCCR) or 200 A (22 kA Maximum SCCR) Meter Socket Positions
No. of Poles 2 3 Factory-Installed Main Lug Ampacity (See page 2-6 for alternate lugs) 200 300 400 400 Al 500 Cu 400 Al 500 Cu 400 400 400 Main Bus Ampacity (A) 200 300 400 500 600 400 400 600 Cat. No. MP22125 b MP33125 c MP44125 c MP55125 c MP66125 c MP42200 c MP43200 c MP64200 c $ Price 977.00 1187.00 1730.00 2079.00 2415.00 1274.00 2151.00 2814.00 3377.00 4040.00 Line Lug Wire Size Al/Cu AWG/kcmil (1) 4250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (2) 3/0500 (2) 3/0500 Circuit Breaker Type (2P) Hub Prov.a A/B300 A-L QO, QO-VH, QOH A-L (4) A-L (4) A-L Semi-Flush Flange Kit MPSF12 MPSF14 MPSF14 MPSF16 MPSF16 MPSF23 QOM2-MM, QOM2-MVH MPSF23 (4) A-L MPSF24 MPSF26 MPSF26 135 173 173 5R 6R 6R Wt Lbs 46 95 97 130 132 99 99 Box No. 1R 2R 2R 3R 3R 4R 4R
125
4 5 6 2 3
200 4 5 600 Al, 750 Cu 800 MP85200 c 6 600 Al, 750 Cu 800 MP86200 c For A and A-L Hubs see page 2-3, for B Hubs see page 3-9. Meets EUSERC standards. Meets EUSERC standards with addition of lug landing kit, MMSK2.
a b c
Table 2.9:
Ringless Type MP Meter-Pak Metering Equipment with 125 A (42 kAMaximum SCCR) or 200 A Type MPR, MPH (22 kA Maximum SCCR) or 225 A Type MPL (100 kA Maximum SCCR) Meter Socket Positions
No. Bypass Cat. No. MPR22125 MPR33125 MPR44125 MPR55125 MPR66125 MPR42200 MPR43200 MPR64200 $ Price Horn Bypass Cat. No. MPH22125 MPH33125 MPH44125 MPH55125 MPH66125 MPH42200 MPH43200 MPH64200 $ Price Lever Bypass Cat. No. MPL32225 MPL53225 MPL64225 $ Price Line Lug Wire Size Al/Cu AWG/kcmil (1) 4250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 (1) 1/0600 or (2) 1/0250 Circuit Breaker Type Hub (2P) Prov. d (See page 2-6) A/B300 A-L MPSF14 MPSF16 (2) A-L MPSF16 QOM2-MM, QOM2-MVH QBP-TM, QDP-TM, QGP-TM or (2) A-L QJ-TM QOe, QO-VHe or QOHe QOM2-MM, QOM2-MVH MPSF23 MPSF23 MPSF24 N/A N/A N/A MPSF26 MPSF26 132 99 99 135 105 147 200 173 173 3R 4R 4R 5R 7R 8R 9R 6R 6R 97 130 2R 3R Semi-Flush Flange Kit MPSF12 MPSF14 QO, QO-VH, QOH Wt Lbs 46 95 Box No. 1R 2R
Factory-Installed Amperes No. Main Lugs Main Bus Per of Pos. Ampacity Pos. (See page 2-6 for Ampacity alternate lugs) 2 200 200 3 125 4 5 6 200 2 3 4 2 3 4 200 d e 300 400 400 Al 500 Cu 400 Al 500 Cu 400 400 400 350 400 400 300 400 500 600 400 400 600 350 500 600
225
5 600 Al, 750 Cu 800 MPR85200 3545.00 MPH85200 3627.00 6 600 Al, 750 Cu 800 MPR86200 4241.00 MPH86200 4341.00 For A and A-L Hubs see page 2-3, for B Hubs see page 3-9. Requires use of EZM125QOA adapter (order separately). Refer to oage 2-15 for pricing.
UL Listed short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
DE4
Discount Schedule
2-5
METERING EQUIPMENT
UL Listed Short Circuit Current Rating depends on lowest interrupting rating of circuit breaker installed. (Refer to the table on the bottom of page 2-9 for Square D certified ratings for downstream panelboards and load centers.) Table 2.10:
Amperes
QDP22200TM 2P, Bolt-on Type Circuit Breaker METERING EQUIPMENT QOM2200MVH MMLK500
For use in 125 A Max. Type MP, MPR and MPH Meter-Pak Metering Equipment 40 QO240 67.00 QO240VHa 146.00 50 QO250 67.00 QO250VHa 146.00 60 QO260 67.00 QO260VH 146.00 70 QO270 134.00 QO270VH 224.00 80 QO280 189.00 QO280VH 315.00 90 QO290 189.00 QO290VH 315.00 100 QO2100 189.00 QO2100VH 315.00 125 QO2125 428.00 QO2125VH 1034.00 For use in 200 A Max. Type MP, MPR and MPH Meter-Pak Metering Equipment 100 QOM2100MM 474.00 QOM2100MVH 1143.00 474.00 QOM2125MVH 1143.00 125 QOM2125MM 150 QOM2150MM 474.00 QOM2150MVH 1143.00 175 QOM2175MM 474.00 QOM2175MVH 1143.00 200 QOM2200MM 474.00 QOM2200MVH 1143.00 For use in 225 A MPL Lever Bypass Meter-Pak Metering Equipment Amperes
2
2-6
10 k AIR $ Price 25 k AIR $ Price 65 k AIR 120/240 Vac (DE2A) 120/240 Vac (DE2A) 120/240 Vac 40 QO240b 67.00 QO240VHacb 146.00 QOH240bd 50 QO250b 67.00 QO250VHacb 146.00 QOH250bda 60 QO260b 67.00 QO260VHacb 146.00 QOH260bda 70 QBP22070TM 474.00 QDP22070TM 1143.00 QGP22070TM 80 QBP22080TM 474.00 QDP22080TM 1143.00 QGP22080TM 90 QBP22090TM 474.00 QDP22090TM 1143.00 QGP22090TM 100 QBP22100TM 474.00 QDP22100TM 1143.00 QGP22100TM 110 QBP22110TM 474.00 QDP22110TM 1143.00 QGP22110TM 125 QBP22125TM 474.00 QDP22125TM 1143.00 QGP22125TM 150 QBP22150TM 474.00 QDP22150TM 1143.00 QGP22150TM 175 QBP22175TM 474.00 QDP22175TM 1143.00 QGP22175TM 200 QBP22200TM 474.00 QDP22200TM 1143.00 QGP22200TM 225 QBP22225TM 474.00 QDP22225TM 1143.00 QGP22225TM a Order only. Not stocked in PDS. Order Point: Lincoln. b Requires use of EZM125QOA adapter (order separately). Refer to page 2-15 for pricing. c QO-VH tenant circuit breakers are rated 22 kAIR at 120/240 Vac. d QOH tenant circuit breakers are rated 42 k AIR at 120/240 Vac.
Accessories
Table 2.11:
Fifth Jaw Kit Horn Bypass Kit QO Adapter
Accessories
$ Price 18.30 16.70 273.00 171.00 171.00 8.00 20.10 16.70 10.10 150.00 200.00 233.00 101.00 134.00 218.00 144.00 171.00 255.00 185.00 276.00 441.00 504.00 504.00 504.00 504.00 504.00 102.00 126.00
Description Cat. No. Fifth Jaw Kit 5J For MPR and MPH only MMHB For Bolt-on Q2M tenant circuit breakers (40125 A, 2P) EZM125QOA 125 A Ring Style 2 Position Top Meter (Only) MM125MBe Slider Type Manual Circuit Closing: 125 and 200 A Ring Style MM200MBe Snap-on Aluminum 2920910001 Sealing Rings: Screw Type Aluminum 29008W Snap-on Type Stainless Steel ARP00026 Meter Cover-Lexan Meter Cover-Lexan 29007 (1) 1/0600 AWG/kcmil or MMLK250fg (2) 1/0250 AWG/kcmil per phase Optional Lug Kits: (2) 3/0500 AWG/kcmil per phase MMLK500g (2) 2600 AWG/kcmil per phase MMLK600g 125 A 2 Position MPSF12 125 A 34 Position MPSF14 125 A 56 Position MPSF16 Semiflush Kits: 200 A 23 Position MPSF23 200 A 4 Position MPSF24 200 A 56 Position MPSF26 For 3 through 6 position 125 A and 200 A devices. Each pad rated 600 A maximum and NEMA/EUSERC Lug Landing Kit: MMSK2g includes (2) 1/2-13 studs and mounting hardware. For use ONLY on MPL43225, MPL53225 and MPL64225 with optional lugs. See wiring NEMA Lug Landing Kit: MMSK4 diagram of each device for optional lugs. 125 A 2 Position ONLY MP43X8PED 125 A 36 Position MP43X11PED 200 A 26 Position MP43X11PED MP Meter-Pak Wireway: (Wall Mount Pedestal) MPL32-225 MP35X11PEDh MPL53-225 MP43X11PED MPL64-225 MP35X11PEDh Used ONLY with MP43X8PED MP12X8PEDEXTh MP Meter-Pak Wireway Extensions: Used with MP43X11PED and MP35X11PED MP12X11PEDEXTh e The meter center short circuit current rating is 10 kA when manual circuit closing is used. Not rated for continuous duty. f Standard lug for 3 through 6 position 125 A and 2 through 4 position 200 A devices. g Cannot be installed on 2 position 125 A device. h Order only. Not stocked in PDS. Order point: Lexington. For hubs and closing plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2-3
Accessory
DE4
DE2A
Discount Schedule
Dimensions
Class 4141
7.28
185
7.28
185
7.28
185
12.28
312
24.34
Top Position Omitted on 3-Gang Unit
618
36.46
926
37.50
953
9.00
9.00
229
229 Typ.
9.00
229 Typ.
48.12
1222
42.37
1076
18.50
470
C,D,F
C,D,F
11.19
284
C,D,F
11.19
284
A,B
C,D,F
Box 1R
C,D,F
Box 3R
A-L Hub Opening Supplied with ACPL Closing Plates
Box 2R
A,B
A-L Hub Opening Supplied with ACPL Closing Plates
8.28
210
8.28
210
8.28
210
29.44
748
46.68
29.44
748
1186
9.00
229 Typ.
9.00
229 Typ.
9.00
229 Typ.
1103
52.00
1321
1103
12.22
C,D,F
310
12.22
C,D,F
310
C,D,F
12.22
310
C,D,E,F
Box 4R
A,B
C,D,E,F
A,B,C
Box 6R
A-L Hub Opening Supplied with ACPL Closing Plates
9.62
244
Box 5R
A,B
9.62
244
19.43
494
9.62
244
35.37
898
35.37
898
14.00
356
60.25
1530
53.12
1349
67.37
1711
34.00
864
14.00
356 Typ.
14.00
356 Typ.
C,D,E,F
13.43
C,D,E,F
341
C,D,E,F
13.43
341
C,D,E,F
C,D,E,F
Box 7R
A,B
Box 8R
A,B
Box 9R
A,B
1-1/4 1-1/2
2-7
43.41
43.41
METERING EQUIPMENT
Branch Units
240 Vac Maximum, for use on AC systems, suitable for use as Service Equipment. Utility Company Requirements Review local utility requirements to ensure that metering equipment meets their standards. EZ Meter-Pak meter center enclosures meet NEC wire bending requirements, and are designed for wall mounting only (not suitable for floor mounting). All unmetered conductor compartments may be sealed by the utility company. EZ Meter-Pak meter centers have UL Listed short circuit current ratings up to 100 kA at 240 Vac when properly applied. For three-tier series ratings refer to Data Bulletin 4100DB0301 and Instruction Bulletin 80043-303-22. Suitable incoming services for an EZM main device and available outgoing feeder(s) to downstream panelboards from EZM branch section(s) Incoming Service to Main Device 120/240 Vac, 13W
125 A and 225 A residential branch units are available in ring type or ringless type construction and are supplied with 800 A continuous aluminum horizontal cross bus as standard (Example: EZM314125). For optional 1200 A continuous copper horizontal cross bus with aluminum vertical connectors, add suffix X to catalog number (Example: EZM314125X). For optional 1200 A continuous all-copper bussing, add suffix CUX to catalog number (Example: EZM314125CUX). NOTE: 5-gang 225 A EZM, EZMR and EZMH residential branch units are supplied with 1200 A continuous Cross Bus as standard, do not add suffix X or CUX to these units (Examples: EZMR315225 or EZMR315225CU). Plug-in style residential meter sockets are available as ring type EZM without bypass, ringless type EZMR without bypass, and ringless type EZMH with horn bypass.
Tenant circuit breakers must be ordered separately for these branch units. 125 A max. units make use of Type QO, QO-VH or QO-H two-pole tenant circuit breakers (40125 A). 225 A max. units make use of Type QDP-TM, QBP-TM, QGP-TM and QJP-TM two-pole tenant circuit breakers (70225 A), and may also make use of two-pole Type QO (40125 A at 10 kA max.), two-pole Type QO-VH (4060 A at 100 kA max.), or two-pole Type QO-H (4060 A at 100 kA max.) tenant circuit breakers. 225 A commercial branch units are available in ring type or ringless type construction and are supplied with 1200 A copper horizontal cross bus with aluminum vertical connectors as standard (Example: EZML314225). For optional 1200 A continuous all-copper bussing, add suffix CU to catalog number (Example: EZML314225CU). Plugin style commercial meter sockets are available as ring type EZMT with test block bypass (meets EUSERC requirements), ringless type EZMR without bypass, and ringless type EZML with lever bypass. 225 A max. units make use of type QDP-TM, QBP-TM, QGPTM and QJP-TM two-pole or three-pole tenant circuit breakers (70 225 A), and may also make use of two-pole type QO (40125 A at 10 kA max.), two-pole type QO-VH (4060 A at 100 kA max.), or two-pole type QO-H (4060 A at 100 kA max.) tenant circuit breakers.
2
METERING EQUIPMENT
120/240 Vac, 13W (4-jaw ring type meter sockets, two-pole circuit breakers) (5-jaw ringless meter sockets, two-pole circuit breakers).
Incoming Service to Main Device 240/120 Vac, 34W Delta Available outgoing feeder(s) to downstream panelboards:
120/240 Vac, 13W (Fed from transformers A-Phase and C-Phase only.) NOTE: Connection to High-Leg B-Phase not permitted for this service (4-jaw ring type meter sockets, two-pole circuit breakers) (5-jaw ringless meter sockets, two-pole circuit breakers) Standard 3 IN/1 OUT branch units are not suitable for use on this Delta System. Special branch units are available for this System by adding suffix: CA to catalog number (Typical Examples: EZM313125CA, EZM313125XCA, EZM313125CUXCA, EZM314225CA, EZM314225XCA, EZM314225CUXCA, EZM315225CA, EZM314225CUCA, etc.). 240/120 Vac, 34W Delta (7-jaw meter sockets, three-pole circuit breakers).
Incoming Service to Main Device 208Y/120 Vac, 34W Available outgoing feeder(s) to downstream panelboards:
120/208 Vac, 13W (5-jaw meter sockets, two-pole circuit breakers) 208Y/120 Vac, 34W (7-jaw meter sockets, three-pole circuit breakers).
Note: QO, QO-VH and QO-H tenant circuit breakers used in 225 A branch units require the use of adapter EZM125QOA (purchased separately). Refer to page 2-15 for pricing. 400 A branch units are available in ringless type
construction only, and are supplied with 1200 A continuous all-copper bussing as standard (Example: EZML332400). These branch units are supplied with factory-installed type DJM tenant circuit breakers that have a field adjustable ampere rating trip setting from 160 A min. to 400 A max. A tamper-evident seal kit is available where needed, order seal kit 29375 (refer to NEC 240-6 [c]). 400 A branch units are available as Type EZML with plug-in style lever bypass type meter sockets, or Type EZMK with bolt-on style with manual bypass type meter sockets. Units having 800 A continuous horizontal cross bus WILL CONNECT with units having 1200 A continuous horizontal cross bus. Single phase units (three bus bars in horizontal cross bus) WILL NOT CONNECT with three phase units (four bus bars in horizontal cross bus).
Main Devices 400, 600 and 800 A main disconnects may be end mounted
with branch units having 800 A or 1200 A continuous horizontal cross bus. 1000 and 1200 A main disconnect or terminal box must be center mounted when used with branch devices with main bus rated 800 A continuous. 1600 A main disconnect or terminal box must be center
mounted.
2000 A main disconnect must be center mounted and requires use of branch units having 1200 A continuous horizontal cross bus. 400, 800 and 1200 A Type EZM-TBU tap boxes supplied with lug landings to meet EUSERC requirements.
Main Circuit Breaker ratings: 400, 600, 800, 1000, 1200, 1600 and 2000 A Main Fusible Switch ratings: 400, 600, 800, and 1200 A (13W only) Main Lugs Terminal Box ratings: 225, 400, 600, 800, 1200, 1600, and 2000 A
For Load Center Three-Tiered Series Ratings used downstream from Metering Equipment, refer to Data Bulletins : 4100DB0301 and 2700DB9901.
2-8
Selection Information
Class 4141
Review local utility requirements to ensure that metering equipment meets their standards. Check local utility to determine available fault current at the meter center.
Table 2.12:
Tenant circuit breakers of same frame size having higher AIR values may replace tenant circuit breakers as listed in tables below and maintain the series rating.
Figures
Figure 1
EZ Meter-Pak (Six Disconnect Rule Applications)See Figure 1 QO (125 A, 2P 40125 A) , 10 kA QO (225 A, 2P 40125 A)d , QB (225 A, 2P or 3P, 70225 A) QO-VH (125 A, 2P, 40125 A ) 22 kA QO-VH (225 A, 2P, 4060 A)d 4002000 A Main Lugs Terminal Box 25 kA QD (225 A, 2P or 3P, 70225 A) (Tenant Circuit Breakers used as Service Disconnects6 maximum) QOH (125 A, 2P, 40125 A) 42 kA QOH (225 A, 2P, 4060 A)d QG (225 A, 2P or 3P, 70225 A) QJ (225 A, 2P or 3P 70225 A) c , DJM (400 A, 2P or 3P, 160400 A)ec EZ Meter-Pak 2252000 A Main Lugs Terminal Box Applications Protected by Remote MainSee Figure 2 QO (125 A, 2P 40125 A) , QO (225 A, 2P 40125 A)d , 10 kA Must be protected by an upstream disconnecting means rated 10 k AIR minimum QB (225 A 2P or 3P 70225 A) , DJM (400 A, 2P or 3P 160400 A)e QO-VH (125 A, 2P, 40125 A) 22 kA QO-VH (225 A, 2P, 4060 A)d Must be protected by an upstream disconnecting means rated 22 k AIR minimum DJM (400 A, 2P or 3P, 160400 A)e QD (225 A 2P or 3P, 70225 A) 25 kA Must be protected by an upstream disconnecting means rated 25 k AIR minimum DJM (400 A, 2P or 3P, 160400 A)e QOH (125 A, 2P, 40125 A) QOH (225 A, 2P, 4060 A)d Must be protected by an upstream disconnecting means rated 42 k AIR minimum DJM (400 A, 2P or 3P, 160400 A)e 42 kA QO-VH (125 A, 2P, 40125 A) Must be protected by a Square D circuit breaker Type LA (400 A max.) or MA QO-VH (225 A, 2P, 4060 A)d (1000 A max.) Rated 42 k AIR minimum QD (225 A 2P or 3P, 70225 A) 100 kA QG (225 A 2P or 3P 70225 A) , DJM (400 A, 2P or 3P, 160400 A)e QO-VH (125 A, 2P, 40125 A) QO-VH (225 A, 2P, 4060 A)d QD (225 A 2P or 3P, 70225 A) QD (225 A 2P or 3P, 70225 A) QJ (225 A 2P or 3P, 70225 A )c DJM (400 A 2P or 3P 160400 A)ec , QO-VH (125 A, 2P, 40125 A) QO-VH (225 A, 2P, 4060 A)d QD (225 A 2P only, 70225 A) Must be protected by an upstream disconnecting means rated 65 k AIR minimum Must be protected by a Square D circuit breaker Type LH (400 A max.), MH (1000 A max.) or PA (1600 A max.) rated 65 k AIR minimum Must be protected by a Square D circuit breaker Type MG (800 A max.), PG (1200 A max.) or RG (2000 A max.) rated 65 k AIR minimum Must be protected by an upstream disconnecting means rated 100 k AIR minimum 65 kA
Transformer
65 kA
Figure 2
Must be protected by an upstream disconnection means with Class R (600 A max.), or Class T (300 Vac, 800 A maximum) fuses. 100 kA Must be protected by an upstream disconnection means with Class J (600 A max.), Class L (1200 A max.), Class R (600 A max.), Class T (300 Vac, 1200 A max.) or Class T (600 Vac, 800 A maximum) fuses, or be protected by a Square D circuit breaker Type MJ (800 A max.), QD (225 A 3P only, 70225 A)c PJ (1200 A max.), PH (1600 A max.) or RJ (2000 A max.) rated 100 k AIR minimum. EZ Meter-PakMain Circuit Breaker ApplicationsSee Figure 3 QO (125 A, 2P 40125 A) , 10 kA QO (225 A, 2P 40125 A)d , QB (225 A 2P or 3P 70225 A) , 4002000 A EZM Main Device with Type LH (400 A Max.), MH (1000 A max.), QO-VH (125 A, 2P, 40125 A) PA (1200 A max.), RG, RJ (1600 A max.) or RJ (2000 A max.) circuit breaker. QO-VH (225 A, 2P, 4060 A)d 65 kA QD (225 A 2P or 3P, 70225 A) DJM (400 A, 2P or 3P, 160400 A)e QO-VH (125 A, 2P, 40125 A) QO-VH (225 A, 2P, 4060 A)d 10001200 A Main Device with catalog number suffix "CBU" supplied with EZM Circuit Breaker Main QD (225 A 2P only, 70225 A) Type MHF circuit breaker. or EZM Main Fusible Switch QD (225 A 3P only, 70225 A)c EZM Branch Units 100 kA DJM (400 A, 2P or 3P, 160400 A)ec QD (225 A 2P only, 70225 A) QD (225 A 3P only, 70225 A)c 16002000 A EZM Main Device with Type RJ (16002000 A) circuit breaker DJM (400 A 2P or 3P 160400 A)ec , EZ Meter-PakMain Fusible Switch ApplicationsSee Figure 3 Transformer Tenant QO (125 A, 2P 40125 A) , Load 400800 A EZM Main Device (1 or 3) with Class T (300 Vac) fuses installed. 1200 A EZM Circuit Centers 10 kA QO (225 A, 2P 40125 A)d , Breakers (Main Lugs) Main Device (1 only) with Class T (300 Vac) fuses installed. QB (225 A 2P or 3P 70225 A) , QO-VH (125 A, 2P, 40125 A) 42 kA Figure 3 QO-VH (225 A, 2P, 4060 A)d 1200 A EZM Main Device (1 only) with Class T (300 Vac) fuses installed. DJM (400 A, 2P 160400 A)e , 100 kA QD (225 A 2P, 70225 A) QO-VH (125 A, 2P, 40125 A) QO-VH (225 A, 2P, 4060 A)d 100 kA QD (225 A 2P, only, 70225 A) 400800 A EZM Main Device (1 or 3) with Class T (300 Vac) fuses installed. QD (225 A 3P only, 70225 A)c DJM (400 A, 2P or 3P, 160400 A)ec a Meter center short circuit current rating is equal to the lowest short circuit current rating given in table for any circuit breaker installed in any meter panelboard in the meter center. b Short circuit current rating is measured at the LINE SIDE terminals of the integral mounted or remote mounted main providing overcurrent protection for the EZM metering equipment lineup. c 3P only tenant circuit breaker(s) are limited to: 100 kA Max. at 208Y/120 Vac or 65 kA Max at 240/120 Vac. d Requires use of EZM125QOA adapter (order separately). Refer to page 2-15 for pricing. e Supplied with factory-installed circuit breaker(s), with an adjustable trip range of 160400 A.
For three-tier series ratings refer to Data Bulletin 4100DB0301 and Instruction Bulletin 80043-303-22.
2-9
METERING EQUIPMENT
EZ Meter-Pak Meter Centers Indoor/Rainproof Meter Centers Class 4161 1 3W 120/240 Vac EZ Meter-Pak Meter Centers1, Indoor/Rainproof, UL Listed
www.schneider-electric.us
Select EZM meter center short circuit current rating from Table 2.12 on page 2-9. Using this table as a reference, make the following selections:
1. 2. 3. 4. 5. Select EZM 1 main device from Table 2.13 or 2.14, below, with an equal or higher short circuit rating than the application. Select EZM 1 branch units from Tables 2.15, 2.16 or 2.17. Select proper 2P type QO, QO-VH, QOH, QBP-TM, QDP-TM, QGP-TM or QJP-TM branch circuit breakers for use as tenant mains in branch unit from Table 2.24, page 2-15. Select accessories as required from Table 2.25, page 2-15. Dimensions; page 2-16.
2
EZM1800CB METERING EQUIPMENT EZM1800CBU
(1) 1600 or (2) 1250 (3) 3/0500 (3) 3/0500 (4) 1/0750 or (8) 1/250
(1) 4300 (2) 3/0500 (2) 1/0750 or (4) 1/0300 (4) 3/0500 (4) 3/0500 (6) 3/0600 6 (Order Lugs Separately)
Table 2.14:
Ampere Horizontal Cross Bus Rating and Rating Bus Bar Material Main Circuit Breakers (1 Incoming and 1 Outgoing)e
Short Circuit Rating 65kA $ Price 100kA $ Price 400 400 A Al EZM1400CBUa 6380.00 20.46 600 600 A Al EZM1600CBUa 9171.00 20.46 800 800 A Al EZM1800CBUa 11762.00 20.46 1000 1000 A Al/Cu EZM11000CBUc 16547.00 34.19 1200 1200 A Al/Cu EZM11200CBUc 21332.00 34.19 1600 1200 A Al/Cu EZM11600GCBUcf 31658.00 EZM11600JCBUcf 36404.00 30.19 2000 1200 A Al/Cu EZM12000CBUfc 52755.00 30.19 Main Fusible Switches (1 Incoming and 1 Outgoing)e Requires 300 Vac Class T Fuses (Order Separately) Short Circuit Rating 400 400 A Al 600 600 A Al 800 800 A Al 1200 1200 A Al/Cu Main Lug Terminal Boxes (1 Incoming and 1 Outgoing) 100kA EZM1400FSU EZM1600FSU EZM1800FSU EZM11200FSUc $ Price 6180.00 9369.00 11564.00 14154.00 20.46 20.46 20.46 34.19
1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 3 (Order Lugs Separately) 3 (Order Lugs Separately) 6 (Order Lugs Separately) 6 (Order Lugs Separately)
1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 3 (Order Lugs Separately)
Short Circuit Rating $ Price 400 800 A Al EZM1400TBUg 1544.00 17.16 1 (Order Lugs Separately) 800 800 A Al EZM1800TBUg 1827.00 25.16 2 (Order Lugs Separately) 1200 1200 A Al/Cu EZM11200TBUcg 3725.00 33.16 3 (Order Lugs Separately) a Available by special order with main circuit breaker supplied with other standard ampere ratings, consult local Field Office (allow 6 weeks for delivery). b Ampere rating of the PA circuit breaker supplied with this main changed to a LOWER value in the field by ordering a different set of rating columns, refer to Supplementary Digest, Section 3 for listing. c Supplied with copper horizontal bus bars and aluminum vertical bus bars. d 225 A tap box supplied with isolated neutral that cannot be bonded. e For mechanical lugs (3/0 AWG600 kcmil) order kit CMELK4, Price $91.00. Kit includes 4 lugs only. Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products Catalog AEC-40R. f Does not meet EUSERC Standards. g Tap box is suitable for use on LINE or LOAD side of service equipment. Supplied with isolated neutral and provided with neutral bonding kit for use as required. Refer to page 2-9 for appropriate short circuit current ratings. h Feed-thru lug kit available, see Accessories, page 2-15.
2-10
DE4
Discount Schedule
Branch Devices
Class 4161
EZMH114125
Table 2.16:
Branch Units225 A Maximum Commercial (Order Type QBP-TM, QDP-TM, QGP-TM or QJP-TM Circuit Breakers Separately, see page 2-15)e
Number of Meter Sockets Horizontal Cross Bus Ratingand Bus Bar Material Ringless Type 5-Jaw Meter Socket with Lever Bypass and Jaw Releasef Cat. No. Width (in.) $ Price Ring Type 5-Jaw Meter Socket with Test Block Bypass. Meets EUSERC Requirements Cat. No.
EZML113225
e f g h i
Width $ Price (in.) 1200 A Al/Cu EZML111225 2453.00 EZMT111225g 22.42 3387.00 1 1200 A Cu EZML111225CU 19.44 3901.00 1200 A Al/Cu EZML111225Dh 2576.00 1200 A Al/Cu EZML112225 4466.00 EZMT112225g 22.42 6143.00 2 1200 A Cu EZML112225CU 19.44 7101.00 13W 1200 A Al/Cu EZML112225Dh 4689.00 120/240 Vac 2P Branch 1200 A Al/Cu EZML113225 6579.00 EZMT113225gi 22.42 9215.00 Circuit Breakers 3 1200 A Cu EZML113225CU 19.44 10461.00 1200 A Al/Cu EZML113225Dh 6908.00 1200 A Al/Cu EZML114225 8813.00 4 1200 A Cu EZML114225CU 19.44 14013.00 1200 A Al/Cu EZML114225Dh 9254.00 2P Type QO (40125 A, 10 kA max. meter center SCCR) or QO-VH and QO-H (4060 A, 100 kA max. meter center SCCR) may be installed using EZM125QOA adapter kit, refer to page 2-15. Supplied with Class 320 lever bypass meter socket. Utilizes anti-inversion clip kit, catalog number MMLRK, if required, refer to page 2-15. Supplied with bondable neutral, suitable for use as service equipment. Use main lugs tapbox type EZM-TBU for Six Disconnect Rule applications to feed this device. Supplied with copper horizontal bus bars and aluminum vertical bus bars. Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided. Does not meet EUSERC 48 in. minImum / 75 in. maximum meter height requirements for outdoor installations. The bottom meter socket is 37 inches above ground when the device is mounted with the top meter socket at 75 inches above ground. EUSERC indoor requirements are 36 in. minimum / 75 in. maximum.
System Type
Table 2.17:
System Type
EZMT111225
13W 120/240 Vac 2P Branch Circuit Breakers j k 1 2
DJM circuit breaker has adjustable trip settings from 160400 A. Use seal kit 29375, if required. DJM circuit breaker terminal lug kit 32508 factoryinstalled and accomodates (1) 2 AWG500 kcmil Al or (1) 2 AWG600 kcmil Cu per phase. Alternate lug kit 32510 for DJM circuit breaker is available, see Accessories, page 2-15. Additional field-installed DJ circuit breaker accessories are available, see page 7-35. Supplied with Class 320 lever bypass meter socket. Utilizes anti-inversion clip kit MMLRK, if required, refer to page 2-15.
DE4
Discount Schedule
2-11
METERING EQUIPMENT
125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately) b 800 A Al EZM113125c 1436.00 EZMR113125c 1436.00 EZMH113125c 1755.00 3 1200 A Cu EZM113125CUX 2282.00 EZMR113125CUX 2282.00 EZMH113125CUX 2282.00 800 A Al EZM114125c 1914.00 EZMR114125c 1914.00 EZMH114125c 2153.00 13W 4 1200 A Cu EZM114125CUX 3043.00 EZMR114125CUX 3043.00 EZMH114125CUX 3043.00 120/240 Vac 12.25 2P Branch 800 A Al EZM115125c 2354.00 EZMR115125c 2354.00 EZMH115125c 2910.00 5 Circuit Breakers 1200 A Cu EZM115125CUX 3742.00 EZMR115125CUX 3742.00 EZMH115125CUX 3742.00 800 A Al EZM116125c 2792.00 EZMR116125c 2792.00 EZMH116125c 3549.00 6 1200 A Cu EZM116125CUX 4438.00 EZMR116125CUX 4438.00 EZMH116125CUX 4438.00 225 A Maximum Branch Units (Order Type QBP-TM, QDP-TM, QGP-TM or QJP-TM Circuit Breakers Separately) d 800 A Al EZM112225c 2273.00 EZMR112225c 2273.00 EZMH112225c 2474.00 2 1200 A Cu EZM112225CUX 3615.00 EZMR112225CUX 3615.00 EZMH112225CUX 3615.00 800 A Al EZM113225c 2792.00 EZMR113225c 2792.00 EZMH113225c 3069.00 13W 3 1200 A Cu EZM113225CUX 4438.00 EZMR113225CUX 4438.00 EZMH113225CUX 4438.00 120/240 Vac 17.38 2P Branch 800 A Al EZM114225c 3588.00 EZMR114225c 3588.00 EZMH114225c 4028.00 4 Circuit Breakers 1200 A Cu EZM114225CUX 5705.00 EZMR114225CUX 5705.00 EZMH114225CUX 5705.00 1200 A Al/Cu EZM115225 4715.00 EZMR115225 4715.00 EZMH115225 4715.00 5 1200 A Cu EZM115225CU 7090.00 EZMR115225CU 7090.00 EZMH115225CU 7090.00 a Snap-on aluminum sealing rings supplied as standard. b Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided. c For 1200 A main cross bus add suffix X to catalog number (Example: EZM314125X). Add 3% adder to list per device. Allow 6 weeks for delivery. d Type QO, QO-VH and QOH branch circuit breakers (4060 A) may be installed with use of EZM125QOA adapter kits, refer to page 2-15.
Main Devices
Class 4162
www.schneider-electric.us
34W 208Y/120 Vac or 240/120 Vac Delta EZ Meter-Pak Meter Centers 3 Indoor/Rainproof, UL Listed
Select EZM meter center short circuit current rating from Table 2.12 on page 2-9. Using this table as a reference, make the following selections:
1. 2. 3. 4. 5. Select 3 EZM main device below with an equal or higher short circuit rating than the application from Tables 2.18 and 2.19. Select EZM 3 branch units from Tables 2.20, 2.21 and 2.22. Select proper 2P type QO, QO-VH, QOH, QBP-TM, QDP-TM, QGP-TM or QJP-TM or 3P QBP-TM, QDP-TM, QGP-TM or QJP-TM branch circuit breakers for use as tenant mains in branch unit; from Table 2.24. Select accessories as required, from Table 2.25. Dimensions, page 2-16.
Ampere Horizontal Cross Bus Rating and Rating Bus Bar Material
Main Circuit Breakers (3 Incoming and 3 Outgoing) 65 kA Short Circuit Current Rating (4001600 A Max.), 100 kA Short Circuit Current Rating (2000 A Max.) Short Circuit Rating 65kA $Price 100kA $Price 400 400 A Al EZM3400CBa 6620.00 18.66 600 600 A Al EZM3600CBa 10247.00 18.66 800 800 A Al EZM3800CBa 13650.00 18.66 1000 1000 A Al EZM31000CBa 17027.00 18.66 1200 1200 A Al/Cu EZM31200CBbc 23127.00 30.19 1600 1200 A Al/Cu EZM31600GCBCc 35288.00 EZM31600JCBCc 40034.00 30.19 2000 1200 A Al/Cu EZM32000CBc 57518.00 30.19 Main Fusible Switches (3 Incoming and 3 Outgoing) Requires 300 Vac Class T Fuses (Order Separately) Short Circuit Rating 400 400 A Al 600 600 A Al 800 800 A Al Main Lug Terminal Boxes (3 Incoming and 3 Outgoing) Short Circuit Rating 225 800 A Al 400 800 A Al 600 800 A Al 800 800 A Al 800 800 A Cu 1600 1200 A Al 2000 1200 A Cu 100kA EZM3400FS EZM3600FS EZM3800FS $Price 4466.00 8373.00 11565.00 $Price 1013.00 1113.00 1196.00 1442.00 3545.00 4028.00 11820.00 18.66 18.66 18.66
2
METERING EQUIPMENT EZM3600FS EZM31600CB
a b c d e f g h
(1) 1600 or (2) 1250 (3) 3/0500 (3) 3/0500 (3) 3/0500 (4) 1/0750 or (8) 1/0250 (6) 1/0750 or (12) 1/0250 (6) 1/0750 or (12) 1/0250
(1) 4300 (2) 3/0500 (2) 1/0750 or (4) 1/0300 (4) 3/0500 (4) 3/0500 (6) 3/0600 6 (Order Lugs Separately)
Table 2.19:
Ampere Horizontal Cross Bus Rating and Rating Bus Bar Material Main Circuit Breakers (3 Incoming and 3 Outgoing)
Short Circuit Rating 65kA $ Price 100kA $Price 400 400 A Al EZM3400CBUa 7178.00 20.46 600 600 A Al EZM3600CBUa 10806.00 26.19 800 800 A Al EZM3800CBUa 14115.00 26.19 1000 1000 A Al/Cu EZM31000CBUc 17943.00 34.19 1200 1200 A Al/Cu EZM31200CBUc 24323.00 34.19 1600 1200 A Al/Cu EZM31600GCBUcf 37170.00 EZM31600JCBUcf 41916.00 30.19 2000 1200 A Al/Cu EZM32000CBUcf 57255.00 30.19 Main Fusible Switches (3 Incoming and 3 Outgoing) Requires 300 Vac Class T Fuses (Order Separately) Short Circuit Rating 400 400 A Al 600 600 A Al 800 800 A Al Main Lugs Terminal Boxes (3 Incoming and 3 Outgoing) 100kA EZM3400FSU EZM3600FSU EZM3800FSU $Price 6978.00 11364.00 15152.00 20.46 26.19 26.19
1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 3 (Order Lugs Separately) 3 (Order Lugs Separately) 6 (Order Lugs Separately) 6 (Order Lugs Separately)
Short Circuit Rating $Price 400 400 A Al EZM3400TBUg 1838.00 17.16 1 (Order Lugs Separately) 800 800 A Al EZM3800TBUg 2100.00 25.16 2 (Order Lugs Separately) 1200 1200 A Al/Cu EZM31200TBUcg 4463.00 33.16 3 (Order Lugs Separately) Available by special order with main circuit breaker supplied with other standard ampere ratings, consult your nearest Field Sales Office (allow 6 weeks for delivery). Ampere rating of the PA circuit breaker supplied with this main can be changed to a LOWER value in the field by ordering a different set of rating columns, refer to Supplementary Digest, Section 3, for listing. Supplied with copper horizontal bus bars and aluminum vertical bus bars. 225 A tap box supplied with isolated neutral that cannot be bonded. For mechanical lugs (3/0 AWG600 kcmil) order kit CMELK4, Price $91.00. Kit includes 4 lugs only. Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products Catalog AEC-40R. Does not meet EUSERC requirements. Tap box is suitable for use on LINE or LOAD side of service equipment. Supplied with isolated neutral and provided with neutral bonding kit for use as required. Refer to page 2-9 for appropriate short circuit current ratings. Feed-thru lug kit available, see Accessories, page 2-15.
2-12
DE4
Discount Schedule
Branch Devices
Class 4162
EZML313225
Table 2.21:
EZMT311225
System Type
Horizontal Number Cross Bus of Rating Meter Sockets and Bus Bar Material
3 Incoming and 1 Outgoing g (Order Type QBP-TM, QDP-TM,QGP-TM or QJP-TM circuit breakers separately) h EZMT311225i 22.42 3545.00 4266.00 EZMT312225i 22.42 6695.00 34W 2 19.44 6785.00 208Y/120 Vac 4479.00 5-Jaw 6420.00 EZMT313225ik 22.42 10041.00 Meter Sockets 2P 3 19.44 10208.00 Branch 6741.00 Circuit 8732.00 Breakers 19.44 13884.00 4 9168.00 3 Incoming and 3 Outgoing (Order QBP-TM, QDP-TM, QGP-TM or QJP-TM circuit breakers separately, see page 2-15) 1200 A Al/Cu EZML331225 2792.00 EZMT331225i 22.42 3938.00 1 1200 A Cu EZML331225CU 19.44 4438.00 34W 1200 A Al/Cu EZML331225Dj 2931.00 240/120 Vac 1200 A Al/Cu EZMR332225 4686.00 EZML332225 5105.00 EZMT332225i 22.42 6957.00 Delta or 2 1200 A Cu EZMR332225CU 19.44 7451.00 EZML332225CU 19.44 8117.00 208Y/120 Vac 1200 A Al/Cu EZML332225Dj 5360.00 7-Jaw 1200 A Al/Cu EZMR333225 7337.00 EZML333225 7794.00 EZMT333225ik 22.42 10304.00 Meter Socket 3P 3 1200 A Cu EZMR333225CU 19.44 11664.00 EZML333225CU 19.44 12395.00 Branch 1200 A Al/Cu EZML333225Dj 8184.00 Circuit 1200 A Al/Cu EZMR334225 10169.00 EZML334225 10667.00 Breakers 4 1200 A Cu EZMR334225CU 19.44 16167.00 EZML334225CU 19.44 16959.00 11214.00 1200 A Al/Cu EZML334225Dj g For 240/120 Vac Delta Systems add Suffix CA to catalog number (Example: EZM314125CA). All meter sockets are phased A and C only. Price remains the same as the base catalog number. Order only branch units, not stocked in PDS (6-week delivery). h 2P Type QO (40125 A, 10 kA max. meter center SCCR) or QO-VH and QO-H (4060 A, 100 kA max. meter center SCCR) may be installed using EZM125QOA adapter kit, refer to page 2-15. i Supplied with bondable neutral, suitable for use as service equipment. Use main lugs tap box type EZM-TBU for Six Disconnect Rule applications to feed this device. Supplied with copper horizontal bus bars and aluminum vertical bus bars. j Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided. k Does not meet EUSERC 48 in. minImum / 75 in. maximum meter height requirements for outdoor installations. The bottom meter socket is 37 inches above ground when the device is mounted with the top meter socket at 75 inches above ground. EUSERC indoor requirements are 36 in. minimum / 75 in. maximum. 400 A maximum Commercial Branch Units . . . . . . . . . . . . . . . . . Page 2-14. 1 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu EZML312225 EZML312225CU EZML312225Dj EZML313225 EZML313225CU EZML313225Dj EZML314225 EZML314225CU EZML314225Dj
DE4
Discount Schedule
2-13
METERING EQUIPMENT
125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)cd 800 A Al EZM313125a 1554.00 EZMR313125a 1554.00 EZMH313125a 1875.00 3 800 A Cu EZM313125M10e 4253.00 1200 A Cu EZM313125CUX 2473.00 EZMR313125CUX 2473.00 EZMH313125CUX 2980.00 800 A Al EZM314125a 2034.00 EZMR314125a 2039.00 EZMH314125a 2474.00 34W 4 800 A Cu EZM314125M10e 5670.00 208Y/120 Vac 5-Jaw-Meter Socket 12.25 1200 A Cu EZM314125CUX 3234.00 EZMR314125CUX 3234.00 EZMH314125CUX 3933.00 2P Branch 800 A Al EZM315125a 2592.00 EZMR315125a 2592.00 EZMH315125a 3111.00 Circuit Breakers 5 800 A Cu EZM315125M10e 7088.00 1200 A Cu EZM315125CUX 4121.00 EZMR315125CUX 4121.00 EZMH315125CUX 4947.00 800 A Al EZM316125a 2991.00 EZMR316125a 2991.00 EZMH316125a 3788.00 6 1200 A Cu EZM316125CUX 4756.00 EZMR316125CUX 4756.00 EZMH316125CUX 6023.00 225 A Maximum (Order Type QBP-TM, QDP-TM,QGP-TM or QJP-TM Circuit Breakers Separately)cf 800 A Al EZM312225a 2273.00 EZMR312225a 2273.00 EZMH312225a 2474.00 2 1200 A Cu EZM312225CUX 3615.00 EZMR312225CUX 3615.00 EZMH312225CUX 2473.00 34W 800 A Al EZM313225a 2792.00 EZMR313225a 2792.00 EZMH313225a 3111.00 3 208Y/120 Vac 1200 A Cu EZM313225CUX 4438.00 EZMR313225CUX 4438.00 EZMH313225CUX 4947.00 5-Jaw-Meter Socket 17.38 800 A Al EZM314225a 3749.00 EZMR314225a 3749.00 EZMH314225a 4148.00 2P Branch 4 Circuit Breakers 1200 A Cu EZM314225CUX 5961.00 EZMR314225CUX 5961.00 EZMH314225CUX 6595.00 1200 A Al/Cu EZM315225 4920.00 EZMR315225 5457.00 EZMH315225 5718.00 5 1200 A Cu EZM315225CU 7409.00 EZMR315225CU 7409.00 EZMH315225CU 8154.00 a For 1200 A main cross bus, add suffix X to catalog number. Example: EZMR313125X. Add 3% adder to list per device. Allow 6 weeks for delivery. b Snap-On aluminum sealing rings supplied as standard. c For 240/120 Vac Delta Systems add Suffix CA to catalog number (Example: EZM314125CA). All meter sockets are phased A and C only. Price remains the same as the base catalog number. Order only branch units, not stocked in PDS (6-week delivery). d Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided. e Distance between meter sockets as measured from centerline to centerline is 10 inches. f 2P Type QO (40125 A, 10 kA max. meter center SCCR) or QO-VH and QO-H (4060 A, 100 kA max. meter center SCCR) may be installed using EZM125QOA adapter kit, refer to page 2-15.
System Type
Ringless Type Meter Socket with Lever Bypass and Jaw Release IncludesFactory-Installed 400 A Type DJM Circuit Breaker. ab Cat. No. Width (in.) $ Price
Ringless Type K Bolt-on Meter Socket with Manual Bypass Includes Factory-Installed 400 A Type DJM Circuit Breaker. a Cat. No. Width (in.) $ Price
3 Incoming and 1 Outgoing c 34W 1 1200 A Cu EZML311400 23.21 5981.00 EZMK311400 27.56 8924.00 208Y/120 Vac 5-Jaw Meter Socket 2 1200 A Cu EZML312400 23.21 11963.00 EZMK312400 27.56 17534.00 2P Branch Circuit Breakers 3 Incoming and 3 Outgoing 34W 1 1200 A Cu EZML331400 23.21 6978.00 EZMK331400 27.56 10515.00 240/120 Vac Delta or 208Y/120 Vac 2 1200 A Cu EZML332400 23.21 13956.00 EZMK332400 27.56 20715.00 7-Jaw Meter Socket 3P Branch Circuit Breakers a DJM circuit breaker has adjustable trip settings from 160400 A. If required, order seal kit, catalog number 29375. DJM circuit breaker terminal lug kit 32508 factory-installed and accomodates (1) 2 AWG500 kcmil Al or (1) 2 AWG600 kcmil Cu per phase. Alternate lug kit 32510 for DJM circuit breaker is available, see Accessories, page 2-15. Additional field-installed DB circuit breaker accessories are available, see page 7-35. b Supplied with Class 320 lever bypass meter socket. Use anti-inversion clip kit, catalog number MMLRK, if required. Order from page 2-15. c For 240/120 Vac Delta Systems add Suffix CA to catalog number (Example: EZML312400CA). All meter sockets are phased A and C only. Price remains the same as the base catalog number. Order only branch units, not stocked in PDS (46 week delivery). Order point Lexington.
2
EZMK311400 METERING EQUIPMENT
Wall
146 C of L Busway
5.75
Width Top of EZM Mounting Channel (See Note) EZM Bus Tap
EZM Mains with Busway Tap (Three Phase OnlyNote positioning left or right below)
Horizontal Cross Bus Rating Main Circuit Breaker with Busway Tap d Neutral Front Neutral Back EZM3400CBNBBTR EZM3600CBNBBTR EZM3800CBNBBTR EZM31000CBNBBTRg EZM31200CBNBBTRfg EZM3400CBNBBTL EZM3600CBNBBTL EZM3800CBNBBTL EZM31000CBNBBTLg EZM31200CBNBBTLfg $ Price Main Fusible Switch with Busway Tap e Neutral Front Neutral Back EZM3400FSNBBTR EZM3600FSNBBTR EZM3800FSNBBTR EZM3400FSNBBTL EZM3600FSNBBTL EZM3800FSNBBTL $ Price 6732.00 10640.00 13830.00 6732.00 10640.00 13830.00
Busway to RIGHT of metering equipment lineup 56.11 400 18.66 400 A Al EZM3400CBNFBTR 1425 C of Busway L 600 18.66 600 A Al EZM3600CBNFBTR Plug-in Opening 800 18.66 800 A Al EZM3800CBNFBTR 31.11 790 1000 18.66 1000 A Al EZM31000CBNFBTRg 4.11 104 1200 30.19 1200 A Al/Cu EZM31200CBNFBTRfg Busway to LEFT of metering equipment lineup Floor Level 400 18.66 400 A Al EZM3400CBNFBTL EZM3800CBNFBTR 600 18.66 600 A Al EZM3600CBNFBTL 800 18.66 800 A Al EZM3800CBNFBTL 1000 18.66 1000 A Al EZM31000CBNFBTLg 1200 30.19 1200 A Al/Cu EZM31200CBNFBTLfg Width
Top of EZM Mounting Channel EZM Bus Tap (See Note)
8886.00 EZM3400FSNFBTR 12513.00 EZM3600FSNFBTR 15744.00 EZM3800FSNFBTR 19292.00 25394.00 8886.00 12513.00 15744.00 19292.00 25394.00 EZM3400FSNFBTL EZM3600FSNFBTL EZM3800FSNFBTL
d e f g Note:
56.11
1425 C of Busway L Plug-in Opening
Has a maximum 65 kA short circuit current rating. Has a 100 kA short circuit current rating. Requires Class T ( 300 Vac) fuses, order separately. Supplied with copper horizontal bus bars and aluminum vertical bus bars. Requires use of branch units supplied with 1200 A horizontal cross bus. Dimensions shown will position the centerline of top meter socket of a 125 A, 5-Gang or 6-Gang branch unit at 72" above floor level. Check with utility to meet local requirements.
31.11
790
4.11
104 Floor Level
EZM3800FSNBBTL
2-14
DE4
Discount Schedule
125 A Max. EZM Branch Unit Tenant Circuit Breakers 40 QO240 67.00 50 QO250 67.00 60 QO260 67.00 70 QO270 134.00 2 80 QO280 189.00 90 QO290 189.00 100 QO2100 189.00 110 QO2110 428.00 125 QO2125 428.00 225 A Max. EZM Branch Unit Tenant Circuit Breakers Ampere 10 k AIR Rating 40 QO240a 67.00 50 QO250a 67.00 60 QO260a 67.00 70 QBP22070TM 474.00 80 QBP22080TM 474.00 90 QBP22090TM 474.00 2 100 QBP22100TM 474.00 110 QBP22110TM 474.00 125 QBP22125TM 474.00 150 QBP22150TM 474.00 175 QBP22175TM 474.00 200 QBP22200TM 474.00 225 QBP22225TM 474.00 70 QBP32070TM 1248.00 80 QBP32080TM 1248.00 90 QBP32090TM 1248.00 100 QBP32100TM 1248.00 110 QBP32110TM 1248.00 3 125 QBP32125TM 1248.00 150 QBP32150TM 1248.00 175 QBP32175TM 1248.00 200 QBP32200TM 1248.00 225 QBP32225TM 1248.00 a Must use EZM125QOA adapter. b QO-VH tenant circuit breaker is rated 22 k AIR max. Poles
25 k AIR QO240VHba QO250VHba QO260VHba QDP22070TM QDP22080TM QDP22090TM QDP22100TM QDP22110TM QDP22125TM QDP22150TM QDP22175TM QDP22200TM QDP22225TM QDP32070TM QDP32080TM QDP32090TM QDP32100TM QDP32110TM QDP32125TM QDP32150TM QDP32175TM QDP32200TM QDP32225TM
65 k AIR
100 k AIR
QDP22200TM
146.00 QOH240ca 317.00 146.00 QOH250ca 317.00 146.00 QOH260ca 317.00 1143.00 QGP22070TM 1521.00 QJP22070TM 1890.00 1143.00 QGP22080TM 1521.00 QJP22080TM 1890.00 1143.00 QGP22090TM 1521.00 QJP22090TM 1890.00 1143.00 QGP22100TM 1521.00 QJP22100TM 1890.00 1143.00 QGP22110TM 1521.00 QJP22110TM 1890.00 1143.00 QGP22125TM 1521.00 QJP22125TM 1890.00 1143.00 QGP22150TM 1521.00 QJP22150TM 1890.00 1143.00 QGP22175TM 1521.00 QJP22175TM 1890.00 1143.00 QGP22200TM 1521.00 QJP22200TM 1890.00 1143.00 QGP22225TM 1521.00 QJP22225TM 1890.00 1784.00 QGP32070TM 2442.00 QJP32070TMd 2796.00 1784.00 QGP32080TM 2442.00 QJP32080TMd 2796.00 1784.00 QGP32090TM 2442.00 QJP32090TMd 2796.00 1784.00 QGP32100TM 2442.00 QJP32100TMd 2796.00 1784.00 QGP32110TM 2442.00 QJP32110TMd 2796.00 1784.00 QGP32125TM 2442.00 QJP32125TMd 2796.00 1784.00 QGP32150TM 2442.00 QJP32150TMd 2796.00 1784.00 QGP32175TM 2442.00 QJP32175TMd 2796.00 1784.00 QGP32200TM 2442.00 QJP32200TMd 2796.00 1784.00 QGP32225TM 2442.00 QJP32225TMd 2796.00 c QOH tenant circuit breaker is rated 42 k AIR max. d 3-pole QJP tenant circuit breaker is rated 65 k AIR max. at 240/120 Vac, 34W High Leg Delta, or 100 k AIR max. at 208Y/120 Vac, 34W.
Accessories
Table 2.25:
Accessory
Accessories (continued)
Description 13W Bus Extension (6 in.wide) 1200 A Bus 13W Bus Extension (12 in.wide) Extension (Indoor/ 34W Bus Extension (6 in. wide) Outdoor Cu bus) 34W Bus Extension (12 in. wide) 13W Inside Corner (14.75 in. wide) 1200 A Bussed 13W Outside Corner (6.20 in. wide) Corner Sections (Indoor Cu bus only) 34W Inside Corner (14.75 in. wide) 34W Outside Corner (6.20 in. wide) 1200 A Transition Add right of old style 1 EZM lineup Sections Add right of old style 3 EZM lineup Old to New Add left of old style 1 EZM lineup (10.7 in. wide Cu Add left of old style 3 EZM lineup bus) Mounting Channel 72" long Secondary Surge For use with 1 or 2-SDSA1175 or 1-SDSA3650 Arrester Mounting kit (order surge arrester separately) Stud Kit for EZM-TB Includes (2) 1/2 in.-13 studs per pad and mounting 400600 A terminal hardware. Four pads per kit. With suffix TBCU only. box
Description Cat. No. $ Price Snap-on (Stainless Steel) ARP00026 16.70 Sealing Rings Screw-Type (Aluminum) 29008W 20.10 Latch-Type (Aluminum)-standard 2920910001 8.00 For use on ringless EZM or MP branch unit covers, Barrel Lock Kit includes 6 each of head protectors, lock nuts and MMBLC 66.00 sealing caps. (Barrel lock not included.) Tenant Circuit 125 A Branches2P Type QO (2 per opening) QOFP 3.60 Breaker Filler Plates 225 A Branches2P and 3P Q-Frame EZMPCP 26.00 e Consult your nearest Square D/Schneider Electric sales office for details. f All sockets include 5th Jaw factory-installed except EZM11__ devices. g Meter center short circuit current rating is 10,000 RMS symmetrical amperes with manual circuit closers installed (bypass is not designed for use as continuous duty). h For use on ring type meter sockets only.
(1) 1/0600 kcmil or (2) 1/0250 kcmil per lug MMLK250 Al/Cu Lug Kits (Each kit includes (2) 3/0500 kcmil per lug MMLK500 three, 2-barrel lugs.) (2) 2600 kcmil per lug MMLK600 Feed -Thru for (4) 750 kcmil Al/Cu lugs per phase and neutral. Al EZM600FTLK3 EZM-TBCU 800 A wire 600 A max. Cu wire 800 A max. Terminal Box Feed-Thru for EZM-TB 1600 A Terminal Box Fifth jaw Kit Horn Bypass Kit Slider Type Manual Circuit Closer Anti-inversion Clip QO Adapter for bolton Q-frame tenant circuit breakers DJM Circuit Breaker Alternate Lug (DE2) DJM Circuit Breaker Seal Kit Meter Socket Closing Plates
Ampere I-Line Busway location Rating 1200 RIGHT of EZM Transition Section 1200 LEFT of EZM Transition Section
409 Width
(24) additional lugs, 600 kcmil Al/Cu, (6) per phase EZM1600FTLK3 915.00 and neutral. 1 per kit 5J f Use with Type EZMR 1 meter socket only MMHB For (1) 125225 A ring-type socket only MM200MBgh indoor/outdoor Rejects 100 A and 200 A watt-hour meters in Class MMLRK 320 meter sockets in Type EZML branch units. For 2P Type QO (40125 A, 10 kA max. meter center SCCR) or QO-VH and QOH (4060 A, 100 EZM125QOA kA max. meter center SCCR) Kit includes (3) 2-barrel lugs for (2) 2/0 AWG350 32510 kcmil AL/Cu or (2) 2/0 AWG500 kcmil AL per lug. Tamper-evident kit to seal DJM trip dial cover, (1) 29375 per circuit breaker, if required. Meets NEC 240-6 [c] Lexan Closing PlateEZM, EZMR, EZMH, EZMT 29007 Metal Closing plateEZMR, EZMH, EZML RSG4 18.30 16.70 171.00 12.00 273.00
16.11 4.11
104
1.00
25
1.00
25
56.11
1425
55.11
1400 Floor Level
55.11
1400 Floor Level
56.11
1425
DE2A
2-15
METERING EQUIPMENT
Dimensions
Class 4162
www.schneider-electric.us
Main Device W T
Branch Device
EZM11000CB 53.97 18.66 11.50 34.30 EZM1ELBOW (indoor only) a EZM11000CBU 70.05 34.19 18.33 46.99 EZM31000CB EZM11200CB 61.19 30.19 18.33 38.13 EZM31000CBU EZM11200CBU 70.05 34.19 18.33 46.99 EZM31200CB EZM11200FS 61.19 30.19 18.33 38.13 EZM31200CBU EZM11200FSU 70.05 34.19 18.33 46.99 EZM31200TBU EZM11200TBU 44.71 33.16 11.68 31.17 EZM31600G/JCBC EZM11600G/JCBC 68.70 30.19 18.33 38.13 EZM31600G/JCBU EZM11600G/JCBU 68.70 30.19 18.33 49.12 EZM31600TB EZM11600TB 55.09 22.48 13.00 27.92 EZM32000CB EZM12000CB 68.70 30.19 18.33 44.25 EZM32000CBU EZM12000CBU 68.70 30.19 18.33 44.25 EZM32000TB EZM12000TB 71.09 30.19 21.46 37.62 EZM3225TB EZM1225TB 21.81 11.66 6.37 13.00 b EZM3400CB EZM1400CB 53.97 18.66 11.50 34.30 EZM3400CBU EZM1400CBU 69.03 20.46 11.50 49.37 EZM3400FS EZM1400FS 53.97 18.66 11.50 34.30 EZM3400FSU EZM1400FSU 69.03 20.46 11.50 49.37 EZM3400TB EZM1400TB 30.46 17.15 7.09 16.29 EZM3400TBU EZM1400TBU 35.71 17.16 8.00 27.17 EZM3600CB EZM1600CB 53.97 18.66 11.50 34.30 EZM3600CBU EZM1600CBU 69.03 20.46 11.50 49.37 EZM3600FS EZM1600FS 53.97 18.66 11.50 34.30 EZM3600FSU EZM1600FSU 69.03 20.46 11.50 49.37 EZM3600TB EZM1600TB 30.46 17.15 7.09 16.29 EZM3800CB EZM1800CB 53.97 18.66 11.50 34.30 EZM3800CBU EZM1800CBU 69.03 20.46 11.50 49.37 EZM3800FS EZM1800FS 53.97 18.66 11.50 34.30 EZM3800FSU EZM1800FSU 69.03 20.46 11.50 49.37 EZM3800TB EZM1800TB 53.97 18.66 11.50 34.30 EZM3800TBCU EZM1800TBCU 51.76 22.48 7.09 28.01 EZM3800TBU EZM1800TBU 39.96 25.16 11.68 31.17 EZM3EXT EZM1EXT 19.34 11.66 6.37 11.85 b EZM3EXT6 EZM1EXT6 19.34 6.00 6.37 11.85 b EZM3CORNER (indoor only) EZM1CORNER (indoor only) c 19.50 14.40 8.02 11.85 b a Each leg of elbow section measures 6.17 in. corner of wall to start of next enclosure. b Device supplied without mounting channel, secure to wall by use of swingable mounting feet. c Each leg of this corner section measures 14.72 in. from wall to start of next enclosure.
Table 2.28:
Single Phase EZM112225 [X, CUX] EZM113125 [X, CUX] EZM113225 [X, CUX] EZM114125 [X, CUX] EZM114225 [X, CUX] EZM115125 [X, CUX] EZM115225 [CU] EZM116125 [X, CUX] EZMH112225 [X, CUX] EZMH113125 [X, CUX] EZMH113225 [X, CUX] EZMH114125 [X, CUX] EZMH114225 [X, CUX] EZMH115125 [X, CUX] EZMH115225 [CU] EZMH116125 [X, CUX] EZMK111400 EZMK112400 EZML111225 [CU] EZML111225D Three Phase EZM312225 [X, CUX, CA, XCA, CUXCA] EZM313125 [X, CUX, CA, XCA, CUXCA] EZM313125M10 EZM313225 [X, CUX, CA, XCA, CUXCA] EZM314125 [X, CUX, CA, XCA, CUXCA] EZM314125M10 EZM314225 [X, CUX, CA, XCA, CUXCA] EZM315125 [X, CUX, CA, XCA, CUXCA] EZM315125M10 EZM315225 [CU, CA, CUCA] EZM316125 [X, CUX, CA, XCA, CUXCA] EZMH312225 [X, CUX, CA, XCA] EZMH313125 [X, CUX, CA, XCA] EZMH313225 [X, CUX, CA, XCA] EZMH314125 [X, CUX, CA, XCA] EZMH314225 [X, CUX, CA, XCA] EZMH315125 [X, CUX, CA, XCA] EZMH315225 [CU, CA, CUCA] EZMH316125 [X, CUX, CA, XCA] EZMK311400 [CA] EZMK312400 [CA] EZMK331400 EZMK332400 EZML311400 [CA] EZML311225 [CU, CA, CUCA] EZML312225 [CU, CA, CUCA] EZML312225D [CA] EZML312400 [CA] EZML313225 [CU, CA, CUCA] EZML313225D [CA] d
MC (Mounting Channel)
MC (Mounting Channel)
2
METERING EQUIPMENT
43.41 17.38 8.09 32.34 22.18 12.23 EZML314225 [CU, CA, CUCA] 42.37 12.25 7.09 31.30 13.18 11.19 EZML314225D [CA] 42.37 12.25 7.09 24.29 10.18 12.19 EZML331225 [CU] 43.41 17.38 8.09 32.34 13.18 12.23 EZML331225D 48.12 12.25 7.09 31.30 9.93 11.19 EZML331400 52.12 12.25 7.09 34.29 9.93 12.19 EZML332225 [CU] 52.00 17.38 8.09 32.34 12.77 12.23 EZML332225D 57.12 12.25 7.09 31.30 9.93 11.19 EZML332400 [CU] 62.12 12.25 7.09 34.29 9.93 12.19 EZML333225 [CU] 61.00 17.38 8.09 32.35 12.77 12.23 EZML333225D 66.12 12.25 7.09 40.30 9.93 11.19 EZML334225 [CU] 43.41 17.38 8.09 32.34 22.18 12.23 EZML334225D 42.37 12.25 7.09 31.30 13.18 11.19 EZMR312225 [X, CUX, CA, XCA] 43.41 17.38 8.09 32.34 13.18 12.23 EZMR313125 [X, CUX, CA, XCA] 48.12 12.25 7.09 31.30 9.93 11.19 EZMR313225 [X, CUX, CA, XCA] 52.00 17.38 8.09 32.34 12.77 12.23 EZMR314125 [X, CUX, CA, XCA] 57.12 12.25 7.09 31.30 9.93 11.19 EZMR314225 [X, CUX, CA, XCA] 61.00 17.38 8.09 32.35 12.77 12.23 EZMR315125 [X, CUX, CA, XCA] 66.12 12.25 7.09 40.30 9.93 11.19 EZMR315225 [CU, CA, CUXCA] 45.55 27.56 9.74 30.60 24.51 21.04 EZMR316125 [X, CUX, CA, XCA] 72.99 27.56 9.74 37.81 22.26 21.04 EZMR332225 [CU] 45.55 27.56 9.74 30.60 24.51 21.04 EZMR333225 [CU] 72.99 27.56 9.74 37.81 22.26 21.04 EZMR334225 [CU] 45.55 23.21 9.44 37.81 24.02 21.53 EZMT311225 [CA] 39.06 19.44 9.44 25.51 25.67 13.39 EZMT312225 [CA] 39.06 19.44 9.44 25.51 11.67 13.39 EZMT313225 [CA] 39.06 19.44 9.44 25.51 11.67 13.39 EZMT331225 69.61 23.21 9.44 37.82 20.64 21.53 EZMT332225 53.06 19.44 9.44 39.51 11.67 13.39 EZMT333225 53.06 19.44 9.44 39.51 11.67 13.39 Standard branch units are available without suffix added.
67.06 67.06 39.06 39.06 45.55 39.06 39.06 69.61 53.06 53.06 67.06 67.06 43.41 42.37 43.41 48.12 52.00 57.12 61.00 66.12 39.06 53.06 67.06 25.45 60.56 79.56 25.12 60.56 79.56
19.44 19.44 19.44 19.44 23.21 19.44 19.44 23.21 19.44 19.44 19.44 19.44 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 19.44 19.44 19.44 22.42 22.42 22.42 22.42 22.42 22.42
9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 8.09 8.09 8.09 7.09 8.09 7.09 8.09 7.09 9.44 9.44 9.44 9.38 9.38 9.38 9.38 9.38 9.38
39.51 39.51 25.51 25.51 37.81 35.51 35.51 37.82 39.51 39.51 39.51 39.51 32.34 31.30 32.34 31.30 32.34 31.30 32.35 40.30 25.51 39.51 39.51 16.19 43.63 48.25 16.19 43.63 48.25
11.67 11.67 25.67 25.67 24.02 11.67 11.67 20.64 11.67 11.67 11.67 11.67 22.18 13.18 13.18 9.93 12.77 9.93 12.77 9.93 11.67 11.67 11.67 4.67 12.67 12.67 4.67 12.67 12.67
13.39 13.39 13.39 13.39 21.53 13.39 13.39 21.53 13.39 13.39 13.39 13.39 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 13.39 13.39 13.39 20.45 28.89 28.89 20.45 28.89 28.89
2-16
Table of Contents
Section 3
Safety Switches
General Duty
Fusible and Non-Fusible Application Data and Dimensions Standards:
UL 98 Enclosed and Dead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1. Enclosed Switches.
3-2 3-3
Light Duty
Fusible Application Data and Dimensions Standards:
General Duty, p. 3-2
UL 98 Enclosed and Dead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1. Enclosed Switches.
3-2 3-3
Heavy Duty
Fusible Non-Fusible Special Application Enclosures
New!
Light Duty, p. 3-2
Motor Disconnect and Receptacle Switches Accessories Application Data and Dimensions Standards:
UL 98 Enclosed and Dead Front Switches. UL Listed under files E2875, E154828, E233505 and E317818. UL 508 Industrial Control Equipment. NEMA Standards Publication KS1 Enclosed Switches (UL98 Switches Only).
Double Throw
Accessories Standards:
Heavy Duty, p. 3-4
UL 98 Enclosed and Dead Front Switches. UL Listed under files E2875 (unless otherwise noted). NEMA Standards Publication KS1 Enclosed Switches (applies to Type DT and DTU series F only).
3-19
3-20 3-23
3-1
SAFETY SWITCHES
3-16
Light Duty
Class 3130 / Refer to Catalog 3100CT0701
www.schneider-electric.us
General DutyUp To 100 kA Short Circuit Current Rating With Proper Current Limiting Fusing
General duty safety switches are designed for residential and commercial applications where durability and economy are prime considerations. Typical loads are lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factory- or field-installed neutral assembly or a field-installed service grounding kit, as applicable. General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1. 400 and 600 A general duty switches (NEMA 1 only) will accept Class J fuses and are UL Listed for use on systems with up to 100 kA available fault current. 600 A requires Class J fuse kitGDJK600 (page 3-3). 400 A requires moving load base. Class T 400800 A general duty safety switches use 300 Vac Class T fuses and are UL Listed for use on systems with up to 100 kA available fault current. Table 3.1:
System A
C223N
UL Listed Short Circuit Withstand Rating Fuse Short Circuit Class Rating Plug 10 kA H 10 kA K 10 kA Fusible J 100 kA R 100 kA T 100 kA H 10 kA K 10 kA Non-Fusiblea J 100 kA R 100 kAb T 100 kA a The UL Listed short-circuit current rating for Square D general duty, not fusible switches is based on the switch being used in conjunction with fuses. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed. For applications requiring greater protection, consider using a heavy duty safety switch. Refer to UL Listed Maximum Short Circuit Current RatingsAC onlyon page 3-6. If a UL Listed short-circuit current rating is required, this non-fusible switch must be replaced with a Square D general duty fusible safety switch equipped with the appropriate class and size fusing. The UL Listed short-circuit current rating of the fusible switch is typically as follows: when used with Class H and K fuses10,000 A, Class R and J fuses100,000 A. Consult the wiring diagram of the switch to verify the UL Listed short-circuit current rating. b 50 kA for 60 A non-fusible switch. Switch Type
Fusible
NEMA 1 Indoor Fuse Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price NEMA 3Ra Rainproof Class R Fuse Kits Field-Installedb Horsepower Ratings Std. (Fast Acting One-Time Fuses) 1 3 Max. (Dual Element Time-Delay Fuses) 1 3
2 Wire (1 Blade and Fuseholder, 1 Neutral)120 Vac 30 Plug Use Light Duty Device for this Application (see below) 30 Cart. Use three-wire devices for this application.
3 Wire (2 Blades and Fuseholders, 1 Neutral)120/240 Vac (Plug), 240 Vac (Cart.) Maximum 30 Plug D211N 90.00 D211NRB 177.00 30 Cart. D221N 122.00 D221NRB 188.00 DRK30 25.65 60 Cart. D222N 206.00 D222NRB 326.00 RFK03H 25.50 100 Cart. D223N 426.00 D223NRB 480.00 RFK10 47.70 200 Cart. D224Ne 884.00 D224NRBe 1200.00 HRK1020 47.70 400 Cart. D225N 2555.00 D225NR 3459.00 DRK40 111.00 600 Cart. D226N 5109.00 D226NR 6569.00 DRK600 111.00 4 Wire (3 Blades and Fuseholders, 1 Neutral)240 Vac Maximum 30 Cart. D321N 188.00 D321NRB 293.00 DRK30 25.65 326.00 D322NRB 441.00 RFK03H 25.50 60 Cart. D322N 100 Cart. D323N 564.00 D323NRB 816.00 RFK10 47.70 200 Cart. D324Ne 1202.00 D324NRBe 1461.00 HRK1020 47.70 400 Cart. D325N 3113.00 D325NR 3893.00 DRK40 111.00 400 Class T D325NT 2994.00 D325NTR 3741.00 600 Cart. D326N 5823.00 D326NR 7877.00 DRK600 111.00 600 Class T D326NT 5598.00 D326NTR 7569.00 800 Class T T327N 9722.00 T327NR 12438.00 a Bolt-on hubsRefer to page 3-11. b When installed, this kit rejects all but Class R fuses. c For corner grounded delta systems only. Use switching poles for ungrounded conductors. d If corner grounded delta, use outer switching poles for ungrounded conductors. e For 200% neutral, order (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI.
3 3 10 15 3 10 15
7-1/2c 15c 30c 60c 7-1/2 15d 30d 60d 125 150
3
SAFETY SWITCHES
Table 3.2:
System
Non-Fusible
A NEMA 1 Indoor Cat. No. $ Price NEMA 3R Rainproof f Cat. No. $ Price Horsepower Ratings (Max.) 1 3
2 Wire (2 Blades)240 Vac Maximum 30 DU221RB 177.00 3 60 DU222RB 353.00 10 60 QO260NATSgh 161.00 QO200TR ghi 161.00 10 100 QO2000NSgh 276.00 QO2000NRBgi 338.00 20 200 Use 3P Switch Use 3P Switch 400 Use 3P Switch Use 3P Switch 600 Use 3P Switch Use 3P Switch 3 Wire (3 Blades)240 Vac Maximum 30 DU321 155.00 DU321RB 293.00 3 7-1/2 60 DU322 206.00 DU322RB 443.00 10 15 100 DU323j 477.00 DU323RBj 816.00 15 30 200 DU324k 884.00 DU324RBk 1461.00 15 60l 400 DU325 2198.00 125 600 DU326l 4191.00 150 f Bolt-on hubsRefer to page 3-11. g Enclosed molded case switchRefer to page 1-24. h Includes factory-installed grounding kit. i Not service entrance ratedRefer to page 1-19 for more information. j If a neutral assembly is required, order and field-install SN0610. k If a neutral assembly is required, order and field install a SN20A Neutral Assembly Kit. For a 200% neutral application, order and field install (2) SN20A Neutral Assembly Kits and (1) SN20NI Neutral Jumper Kit. l If a neutral assembly is required, order part number D600SN. Available for field-installation.
Fusible
Rating (A) Fuse NEMA 1 Indoor Horsepower Ratings Std. Max. Cat. No. n $ Price Std. 3 Wire (2 Blades and Fuseholders, 1 Neutral)120/240 Vac 30 Plug Cart. L211N L221N 72.00 98.00 1-1/2 m 1-1/2 m System A Fuse NEMA 1 Indoor Horsepower Ratings Max.
3m 3m
L221N
m n
30
Plug
L111N
$54.00
1/2
2 30
For single phase hp rating, use two switching poles. DE1A Discount Schedule.
3-2
DE1A
DE2A
Discount Schedule
Table 3.5:
Series E 60
PK3GTA1
11.40
Electrical interlock kit catalog numbers with -1 suffix indicates one normally open and one normally closed contact; -2 indicates two normally open and two normally closed contacts. Kits are UL Listed.
Table 3.6:
Rating (A) 30 60 100 200
Wire Range Conductors Wire Bending Space Per NEC Table 312.6 Per Phase AWG/kcmil 1 1 1 1 1 or 2 126 (Al) or 146 (Cu) 103 (Al) or 143 (Cu) 121 (Al) or 141 (Cu) 6 250 (Al/Cu) 1/0 600 (Al/Cu) or 1/0 300 (Al/Cu)
126 (Al) or 146 (Cu) 102 (Al) or 142 (Cu) 121/0 (Al) or 141/0 (Cu) 6 300 (Al/Cu) (1) 1/0 750 (Al/Cu) 400 or NEMA 1 (2) 1/0 300 (Al/Cu) (1) 1 600 (Al/Cu) 400 2 1/0250 (Al/Cu) or NEMA 3R (2) 1/0 250 (Al/Cu) 600 2 4 500 (Al/Cu) 4 600 (Al/Cu) 800 3 3/0 500 (Al/Cu) 3/0 500 (Al/Cu) b 30100 A switches suitable for 60oC or 75oC conductors. 200800 A switches suitable for 75oC conductors.
NOTE: Field-installed lug kits are located in the Supplemental Digest page 2.2.
W/H D
Table 3.7:
Cat. No.
Approximate Dimensions
Series Series E1 E3 E3 E1 E1 E2 E1 E2 E2 E1 E1 F3 F3 F1 F1 E3 E3 G3 E2 E1 E1 E1 E1 H in. 30.63 49.13 49.13 49.13 49.13 9.63 9.63 9.25 9.63 9.25 9.63 17.50 17.50 29.00 29.25 45.12 49.13 6.50 9.25 14.00 13.38 49.13 49.13 mm 778 1248 1248 1248 1246 245 245 235 245 235 245 445 445 737 743 1146 1248 165 235 356 340 1248 1248 W W/H D Std. in. mm in. mm in. mm Pack 21.38 543 22.25 565 10.13 257 1 24.00 610 24.88 632 8.88 226 1 24.00 610 24.88 632 8.88 226 1 24.75 629 25.13 638 8.88 226 1 24.75 629 25.13 638 8.88 226 1 7.25 184 7.75 197 3.75 95 5 7.25 184 7.75 197 3.75 95 5 6.75 171 7.25 184 3.63 92 5 7.25 184 7.75 197 3.75 95 5 6.75 171 7.25 184 3.63 92 5 7.25 184 7.75 197 3.75 95 5 8.50 216 10.50 267 6.50 165 1 8.50 216 10.50 267 6.50 165 1 17.25 438 19.00 483 8.25 210 1 17.25 438 19.00 483 8.25 210 1 24.00 610 24.88 632 8.88 226 1 24.00 610 24.88 632 8.88 226 1 4.63 118 3.88 99 5 4.88 124 3.25 83 1 7.75 197 4.50 114 1 6.13 156 3.50 89 1 24.00 610 24.88 632 8.88 226 1 24.75 629 25.13 638 8.88 226 1
H W W/H D Std. Cat. No. in. mm in. mm in. mm in. mm Pack L111N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D325NTRc L211N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D326Nc L221N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D326NTc D211Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 D326NRc D211NRBc E2 9.63 245 7.25 184 7.75 197 3.75 95 5 D326NTRc D221Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 DU221RBc D221NRBc E3 9.63 245 7.25 184 7.75 197 3.75 95 5 DU222RBc D222N F1 14.63 372 6.50 165 7.45 189 4.88 124 1 DU321c D222NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1 DU321RBc D223N F3 17.50 445 8.50 216 10.50 267 6.50 165 1 DU322c D223NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 DU322RBc D224N F1 29.00 737 17.25 438 19.00 483 8.25 210 1 DU323 D224NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 DU323RB D225N E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 DU324 D225NR E1 30.63 778 21.38 543 22.25 565 10.13 257 1 DU324RB D226Nc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 DU325c D226NRc E1 49.13 1248 24.75 629 25.13 638 8.88 226 1 DU326c D321Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 QO200TRc D321NRBc E3 9.63 245 7.25 184 7.75 197 3.75 95 5 QO260NATSc D322N F1 14.63 372 6.50 165 7.45 189 4.88 124 1 QO2000NRBc D322NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1 QO2000NSc D323N F3 17.50 445 8.50 216 10.50 267 6.50 165 1 T327Nc D323NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 T327NRc D324N F1 29.00 737 17.25 438 19.00 483 8.25 210 1 D324NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 D325Nc E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D325NTc E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D325NRc E1 30.63 778 21.38 543 22.25 565 10.13 257 1 c 30100 A switches suitable for 60oC or 75oC conductors. 200800 A switches suitable for 75oC conductors.
DE1
DE3A
Discount Schedule
3-3
SAFETY SWITCHES
240 Volt
Class 3110 / Refer to Catalog 3100CT0701
www.schneider-electric.us
Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety switches feature quick-make, quick-break operating mechanism, a dual cover interlock and a color coded indicator handle. They are suitable for use as service equipment when equipped with a field- or factory-installed neutral assembly or equipment grounding kit, unless a 600Y/347 V or 480 Y/277 V, 1000 A or greater, solidly grounded WYE system is used, per NEC 215-10. Heavy duty safety switches are UL Listed (except as noted), File E2875 and 154828 and meet or exceed the NEMA Standard KS1. For UL Listed short circuit current ratings, see page 3-6.
NEMA 1
NEMA 12
Table 3.8:
System
Amperes
NEMA 1 Indoor
Cat. No.
$ Price
2-Wire (2 Blades and Fuseholders)240 Vac, 250 Vdc 30 H221DS 1947.00 H221A 504.00 H221AWK 473.00 1-1/2 3e 3 7-1/2e 30 H2212AWKf 588.00 1-1/2 3 Use three-wire devices 60 H222DS 2337.00 H222AWK 647.00 3 7-1/2 e 10 15 e For two-wire applications 100 H223DS 5094.00 H223A 1008.00 H223AWK 948.00 7-1/2 15 e 15 30 e 200 H224DS 6960.00 H224A 1737.00 H224AWK 1643.00 15 25 e 60 e 400 H225 2729.00 H225R 3884.00 H225DS 14481.00 H225AWK 4163.00 600 H226 5424.00 H226R 7281.00 H226DS 20772.00 H226AWK 6543.00 75 e 200 e 800 H227 8459.00 H227Rg 11483.00 H227AWK 10325.00 50 50 1200 H228 11682.00 H228Rg 15486.00 H228AWK 15815.00 50 50 3-Wire (2 Blades and Fuseholders, 1 Neutral)240 Vac, 250 Vdc 30 H221N 236.00 H221NRB 447.00 1-1/2 3 e 3 7-1/2 e Use two-wire devices, 60 H222N 471.00 H222NRB 842.00 3 7-1/2 e 10 15 e Field-installed solid neutral assemblies 100 H223N 716.00 H223NRB 1086.00 7-1/2 15 e 15 30 e Order separately See page 3-12. 200 H224N 1289.00 H224NRB 1562.00 15 25 e 60 e 400 H225N 3092.00 H225NR 4245.00 H225NDS 14787.00 H225NAWK 4304.00 50 e 125 e 600 H226N 5819.00 H226NR 7677.00 H226NDS 21081.00 H226NAWK 6936.00 75 e 200 e 800 H227N 10067.00 H227NRg 12216.00 H227NAWK 12338.00 50 50 1200 H228N 12422.00 H228NRg 16665.00 H228NAWK 17184.00 50 50 3-Wire (3 Blades and Fuseholders)240 Vac, 250 Vdc 30 H321DS 2049.00 H321A 639.00 H321AWK 639.00 1-1/2 3 3 7-1/2 60 H322DS 2532.00 H322A 914.00 H322AWK 864.00 3 7-1/2 10 15 Use four-wire devices For three-wire applications 100 H323DS 5346.00 H323A 1412.00 H323AWK 1331.00 7-1/2 15 15 30 200 H324DS 7496.00 H324A 2040.00 H324AWK 1926.00 15 25 60 400 H325 3425.00 H325R 3975.00 H325DS 14961.00 H325AWK 4253.00 50 125 600 H326 6170.00 H326R 8286.00 H326DS 21399.00 H326AWK 7365.00 75 200 800 H327 11456.00 H327Rg 14849.00 H327AWK 14528.00 50 100 50 250 1200 H328 14517.00 H328Rg 18728.00 H328AWK 17450.00 50 100 50 250 4-Wire (3 Blades and Fuseholders, 1 Neutral)240 Vac, 250 Vdc 30 H321N 314.00 H321NRB 555.00 1-1/2 3 3 7-1/2 Use three-wire devices, 60 H322N 528.00 H322NRB 891.00 3 7-1/2 10 15 Field-installed solid neutral assemblies 100 H323N 842.00 H323NRB 1278.00 7-1/2 15 15 30 Order separately. See page .3-12 200 H324N 1451.00 H324NRB 1748.00 15 25 60 400 H325N 3788.00 H325NR 4322.00 H325NDS 15321.00 H325NAWK 4635.00 50 125 600 H326N 6519.00 H326NR 8622.00 H326NDS 21759.00 H326NAWK 7757.00 75 200 800 H327N 12189.00 H327NRg 15563.00 H327NAWK 15879.00 50 100 50 250 H328NAWK 20015.00 50 100 50 250 1200 H328N 15314.00 H328NRg 19709.00 4-Wire (4 Blades and Fuseholders) 30 60 100 Use 600 Vac devices. See page 3-5. 200 400 600 a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. For NEMA 3R applications, remove drain screw from bottom endwall. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-31 for additional motor application data. The starting current of motors of more than standard horsepower may require the use of fuses with appropriate time delay characteristics. d For switching dc, use two switching poles. e For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors. f 60 ampere switch with 30 ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks. g Suitable for NEMA 5 applications with drain screw installed. Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-11 through 3-13 Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-14 Dimensions: NEMA 4, 4X and 5 Stainless and NEMA 12 . . . . . . . page 3-15
3
SAFETY SWITCHES
3-4
DE1
Discount Schedule
600 Volt
Class 3110 / Refer to Catalog 3100CT0701
Table 3.9:
System
Amperes
NEMA 1 Indoor
dce
Cat. No. 30 60 100 200 400 600 800 1200 30 30 60 100 200 400 600 800 1200 30 60 100 200 400 600 800 1200 30 60 100 200 400 600 100 200 a b c d e f g h
$ Price
Cat. No.
$ Price
Cat. No.
$ Price
250 600 50 50 50 50 5 40 50 50 50 50 40 50 50 50 50 5 10 20 40 50 50 50 50 50 50 15 15 30 50 50 50 50 50 50 15 30 50 50 50 50 50 50 15 30 30 50 50 50
For applications requiring motor disconnect 12222.00 capability, use electrical interlock. Refer to page 3-11.
Class R Fuse
DE1
Discount Schedule
3-5
SAFETY SWITCHES
Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. Also suitable for NEMA 3R application by removing drain screw from bottom endwall. Refer to page 7-35 for additional motor application data. The starting current of motors of more than standard horsepower may require the use of fuses with appropriate time delay characteristics. For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors. On 3P devices, use two outside poles for switching dc. 60 A switch with 30 A fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks. Suitable for NEMA 5 applications with drain screw installed. Not suitable for use as service equipment.
Table 3.10:
System
Rating (A)
NEMA 1 Indoor
Cat. No.
$ Price
Cat. No.
$ Price
3 1 3 250 600 50 50 50 50 50 50 50 50
2-Wire (2 Blades)600 Vac, 600 Vdc 30 60 Use three-wire devices for two-wire applications. 100 200 400 HU265 2750.00 HU265R 3764.00 HU265DS 12812.00 HU265AWK 600 HU266 4896.00 HU266R 7533.00 HU266DS 18455.00 HU266AWK 800 HU267 7467.00 HU267Re 12884.00 HU267AWK 1200 HU268 10226.00 HU268Re 17393.00 HU268AWK 3-Wire (3 Blades)600 Vac, 600 Vdc 30 HU361 279.00 HU361RB 488.00 HU361DS 2520.00 HU361A 689.00 HU361AWK 30 HU361EIf 638.00 HU361RBEIf 846.00 HU361DSEIf 2480.00 HU361AEIf 1047.00 HU361AWKEIf 30 HU3612g 369.00 HU3612RBg 638.00 HU3612Ag 710.00 HU3612AWKg 60 HU362 488.00 HU362RB 876.00 HU362DS 2520.00 HU362A 875.00 HU362AWK 60 HU362DSEIf 2972.00 100 HU363 783.00 HU363RB 1226.00 HU363DS 5102.00 HU363A 1265.00 HU363AWK 200 HU364 1209.00 HU364RB 1485.00 HU364DS 6960.00 HU364A 1697.00 HU364AWK 400 HU365 2804.00 HU365R 3840.00 HU365DS 14294.00 HU365AWK 600 HU366 4992.00 HU366R 7683.00 HU366DS 19062.00 HU366AWK 800 HU367 9978.00 HU367Re 13050.00 HU367AWK 1200 HU368 13421.00 HU368Re 17867.00 HU368AWK 4-Wire (4 Blades)600 Vac, 600 Vdc k 30 HU461h 827.00 HU461DS 2586.00 HU461AWKi 60 HU462h 914.00 HU462DS 3027.00 HU462AWK 100 HU463h 1647.00 HU463DS 7401.00 HU463AWK 200 HU464h 2399.00 HU464DS 11244.00 HU464AWK 400 HU465 5201.00 HU465AWK 600 HU466 9072.00 6-Wire (6 Blades)600 Vack 30 HU661DS 11903.00 HU661AWKl 13254.00 HU662AWKl 60 HU662DS 100 HU663DS 20643.00 HU663AWKl 200 HU664DS 28316.00 HU664AWKl a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-32 for additional motor application data. d For switching dc, use two switching poles. e Suitable for NEMA 5 applications with drain screw installed. f Switches with EI suffix are stocked with factory-installed electrical interlocks with one normally-open and one normally-closed contact. g Use 60 A enclosure accessories, including electrical interlocks. h No knockouts are provided. i Check series number on switch for correct accessory. See page 3-15. j HU461AWK (Series E1) is rated 5 hp@250 Vdc, 10 hp@600 Vdc. k Not suitable for use as service equipment. l One enclosure for NEMA 1, 3, 3R or 12 applications. UL Listed.
3212.00 5408.00 12957.00 17522.00 647.00 1007.00 666.00 833.00 1194.00 1604.00 4023.00 6711.00 13097.00 17940.00 915.00 1008.00 1791.00 2832.00 5672.00 3357.00 3884.00 4793.00 10538.00
10 7-1/2 20 10 30 5 15 10 7-1/2 20 10 30 5 15 10 7-1/2 20 10 30 5 15 20 25 50 30 60 10 30 20 25 50 30 60 10 30 40 40 75 40 100 20 50 60 50 125 50 150 40 50 125 250 350 50 50 200 400 500 50 50 250 50 500 50 500 50 50 250 50 500 50 500 50 50 3 2 3 2 3 10 20 20 25 30 10j 15j 20 40 50 50 60 10 30 40 50 75 50 75 20 30 60 50 125 50 150 40 50 125 250 350 50 50 200 400 500 50 50 3 3 3 10 20 30 20 50 60 40 75 75 60 125 150
3
SAFETY SWITCHES
UL Listed Maximum Short Circuit Current RatingsAC only Non-Fusible Safety Switches
NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with an non-fusible safety switch when there is up to 10 kA short circuit current available (see table below). Above 10 kAWhen applied on systems with greater than 10 kA short circuit current available, the UL Listed short circuit current rating for Square D non-fusible switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.12: Non-Fusible Safety Switches
Fuse or Circuit Breaker Typeo 3-Phase 240 Vac
Table 3.11:
For the short circuit current rating, refer to the table below. UL Listed UL Listed Short Circuit Fuse Class Current Ratings H, K 10 kA Fusible R, J, L 200 kAm On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when protected by Class J or R fuses. Heavy Duty Safety Switch Type
480 Vac 600 Vac Any brand circuit breaker Up to 10 kA All H, K R,T,J.L 200 kA 200 kA 200 kA 30100 Hp 65 kA 35 kA 25 kA 30100 FA 14 kA 14 kA 14 kA Non-Fusible 30100 FH 18 kA 18 kA 18 kA Switches 200 H, J p 65 kA 35 kA 25 kA 200 KA 400 LA 22 kA 22 kA 22 kA 600 MA 200 KH 400 LH 25 kA 25 kA 25 kA 600 MH n Applies to NEMA 1, 3R, 4X stainless, 12 switches. o Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. p All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Ratings. 2009 Schneider Electric All Rights Reserved
3-6
DE1
Discount Schedule
Special Applications
Class 3110 / Refer to Catalog 3100CT0701
H361SS
H363DF
Krydon EnclosuresNEMA 4X
Krydon enclosures are compression molded of fiberglass reinforced polyester, specially formulated to withstand attack from almost any corrosive atmosphere found in the toughest industrial application. Switches are furnished with hubs (page 3-15) and equipment grounding lugs. UL Listed. Table 3.15:
Amperes Fusible 30 60 100 Non-Fusible 30 60 100
H361DX
NEMA 7 and 9
An enclosed automatic molded case switch for use in Divisions 1 and 2 of the following: Class I, Groups C and D; Class II, Groups E, F and G; or Class III, Hazardous Locations as defined in NEC Article 500. Furnished with threaded conduit openings in both top and bottom endwall (page 3-15). Suitable for use as service equipment and listed as Raintight for outdoor applications. UL Listed, and CSA Certified. Equipment grounding lugs supplied as standard. Table 3.16:
Amperes
3P, Non-Fusible, 600 Vac, 250 Vdc Maximum, Short Circuit Rating 10 kA AIR
Enclosed Molded Case Switchd Solid Neutral Assembly Horsepower Ratings3 600 Vacb 50 50 75 75 150 150
H60XFA
a b c d e
Cat. No. $ Price Cat. No. $ Price 240 Vac 480 Vac 60 H60XFA 2571.00 100SNA 143.00 15 30 60 H60XFA1212 2886.00 100SNA 143.00 15 30 100 H100XFA 3045.00 100SNA 143.00 30 60 100 H100XFA1212 3287.00 100SNA 143.00 30 60 225 H225XJG 6387.00 225SNA 189.00 60 125 225 H225XJGAAe 6701.00 225SNA 189.00 60 125 Std.Using fast acting one time fuses. Max.Using dual element time delay fuses. For switching dc use two switching poles. Electrical interlock not available. For auxiliary switches, refer to page 7-4 for catalog number suffix and price adder (e.g. H60XFA1212). Includes PKDB1, breather and drain kit, required for rainproof applicationNEMA 7 only. Includes auxiliary contacts.
DE1
Discount Schedule
3-7
SAFETY SWITCHES
New!
The MD50 Motor Disconnect Switch merges three key product features to provide safe, quick and reliable mating of mobile and fixed motors to power connections. The features include the UL508 Suitable for Motor Disconnect switch, the IEC 60309-2 pin and sleeve technology, and the mechanical interlock integrated in a rugged plastic enclosure. The mechanical interlock prevents the making or breaking under load of plug-connected equipment. The plug must be inserted before the power can be turned ON. The plug cannot be removed until the power is turned OFF. The combination of the MD50s UL508 listing, IEC 60309 technology, and the rugged plastic enclosure, provides a set of features for motor disconnecting not available in the existing UL98 Receptacle Switch offering. Grounding and conduit hub included. Table 3.17:
System
Non-Fusiblea
NEMA 4X and 12 Use with Plug Amperes Voltage Cat No. $ Price Cat. No. $ Price Horse Power Rating
Wire Phase Size (Cu) 125 MD330MI4 1236.00 ME330P4W 214.00 2 1 128 30 2-Pole 3-Wire 250 MD330MI6 1249.00 ME330P6W 214.00 5 1 128 60 250 MD360MI6 1638.00 ME360P6W 352.00 10 1 62 250 MD420MI9 1181.00 ME420P9W 162.00 7.5 3 128 20 480 MD420MI7 1181.00 ME420P7W 162.00 15 3 128 250 MD430MI9 1143.00 ME430P9W 236.00 10 3 128 30 480 MD430MI7 1143.00 ME430P7W 236.00 20 3 128 600 MD430MI5 1335.00 ME430P5W 236.00 20 3 128 250 MD460MI9 1561.00 ME460P9W 344.00 20 3 62 3-Pole 4-Wire 60 480 MD460MI7 1561.00 ME460P7W 344.00 40 3 62 600 MD460MI5 1961.00 ME460P5W 344.00 50 3 62 125/250 MD4100MI12 1773.00 ME4100P12W 465.00 125 V 5, 250 V 15 1 61/0 240 MD4100MI9 2123.00 ME4100P9W 465.00 25 3 61/0 100 480 MD4100MI7 1911.00 ME4100P7W 465.00 50 3 61/0 600 MD4100MI5 2123.00 ME4100P5W 465.00 50 3 61/0 Y120/208 MD530MI9 1233.00 ME530P9W 292.00 7.5 3 128 30 Y277/480 MD530MI7 1331.00 ME530P7W 292.00 20 3 128 Y347/600 MD530MI5 1331.00 ME530P5W 292.00 20 3 128 Y120/208 MD560MI9 1627.00 ME560P9W 409.00 20 3 62 4-Pole 5-Wire 60 Y277/480 MD560MI7 1709.00 ME560P7W 409.00 40 3 62 Y347/600 MD560MI5 1953.00 ME560P5W 409.00 50 3 62 Y120/208 MD5100MI9 2123.00 ME5100P9W 560.00 25 3 61/0 100 Y277/480 MD5100MI7 2123.00 ME5100P7W 560.00 50 3 61/0 Y347/600 MD5100MI5 2123.00 ME5100P5W 560.00 50 3 61/0 a Suitable for use on a circuit capable of delivering not more than 10,000 RMS symmetrical amperes at the voltage rating of the receptacle.
NOTE: Auxiliary Contacts ordering information: 20 and 30 A non-fusibleME2030AUX 60 and 100 A non-fusibleME80AUX Table 3.18: Fusible (Type J Fuses Only) bc
NEMA 4X and 12 Use with Plug Voltage Cat. No. $ Price Cat. No. $ Price Horse Power Rating
3
SAFETY SWITCHES
Horse Wire Power Rating Phase Size (Cu) Max. 250 MD430MIF9 1631.00 ME430P9W 236.00 3 7.5 3 188 30 480 MD430MIF7 2053.00 ME430P7W 236.00 5 15 3 188 600 MD430MIF5 1794.00 ME430P5W 236.00 7.5 20 3 188 3-Pole 4-Wire 250 MD460MIF9 2013.00 ME460P9W 344.00 7.5 15 3 144 60 480 MD460MIF7 2129.00 ME460P7W 344.00 15 30 3 144 600 MD460MIF5 2123.00 ME460P5W 344.00 15 30 3 144 b Suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes at the voltage rating of the receptacle. c UL98 Listed. System Amperes
3-8
DE1
Discount Schedule
New!
Dimensions
4.65 [118] 3.97 [101] 0.21 [5] 10.04 [255] 8.86 [225] 8.19 [208] 10.30 [262] 8.87 [225] 5.50 [140] 6.56 [167] 6.00 [153]
12.00 [305]
30 A Non-Fusible 20 or 30 A Non-Fusible
MD420MI7 MD420MI9 MD530MI5 MD530MI7 MD530MI9 MD330MI4 MD330MI6 MD430MI5 MD430MI7 MD430MI9
0.38 [10]
11.13 [283]
8.63 [219] 11.50 14.62 13.00[ 330] [292] [371] 18.13 [461] 17.25 [438] 8.63 [219]
20.63 [524]
9.50 [241]
9.00 [229]
MD360MI6 MD460MI5 MD460MI7 MD460MI9 MD560MI5 MD560MI7 MD560MI9
12.00 [305]
14.50 [368]
6.87 [175]
9.25 [235]
30 A Fusible
MD430MIF5 MD430MIF7 MD430MIF9
60 A Fusible
MD460MIF5 MD460MIF7 MD460MIF9
3-9
SAFETY SWITCHES
60 A Non-Fusible
100 A Non-Fusible
Receptacle Switches
Class 3110 / Refer to Catalog 3100CT0701
www.schneider-electric.us
Devices are UL Listed and CSA Certified, suitable for use as service equipment. Receptacles are epoxy powder coated over copper-free cast aluminum and NEMA 3, 3R, 4, 4X and 12 rated. Appleton receptacles are UL Classified for use with the Crouse-Hinds plugs listed below. Short circuit rating: 10 kA when used in conjunction with Class H or K fuses; 200 kA when used in conjunction with Class R or J fuses.
NEMA 3, 3R, 4, 4X, 5, 12 304 Stainless Steel Enclosure Cat. No. $ Price
NEMA 12, 3R
Cat. No.
$ Price
Cat. No.
$ Price
Fusible3P, 600 Vac, 250 Vdc 30 H361WA 2076.00 H361DSWA 4401.00 H361AWA 2289.00 ACP3034BC 1235.00 5 15 7-1/2 20 5 60 H362WA 2412.00 H362DSWA 4668.00 H362AWA 2508.00 ACP6034BC 1295.00 15 30 15 50 10 100 H363WA 3689.00 H363DSWA 8468.00 H363AWA 3758.00 ACP1034CD 1928.00 25 60 30 75 20 Non-Fusible3P, 600 Vac, 250 Vdc 30 HU361WA 1893.00 HU361DSWA 4001.00 HU361AWA 2076.00 ACP3034BC 1235.00 20 30 60 HU362WA 2306.00 HU362DSWA 4412.00 HU362AWA 2357.00 ACP6034BC 1295.00 50 60 100 HU363WA 3153.00 HU363DSWA 8010.00 HU363AWA 3347.00 ACP1034CD 1928.00 75 100 a Receptacle UL Listed for use with Appleton ACP or CPH plugs; UL Classified for use with Crouse-Hinds APJ Arktite plugs listed on this page. b Std.Using fast acting one time fuses. Max.Using dual element time delay fuses. c For switching dc, use two switching poles.
UL Listed, suitable for use as service equipment. Short circuit ratings: 10 kA when used in conjunction with Class H or K fuses; 200 kA when used in conjunction with Class R or J fuses.
Table 3.19:
NEMA 1 Amperes Cat. No. $ Price NEMA 3, 3R, 4, 4X, 5, 12 304 Stainless Steel Enclosure Cat. No. $ Price NEMA 12, 3R Use with Plug Horsepower Ratings3d 480 Vac Std. 5 15 Max. 15 30 60 20 50 60 600 Vac Std. 7-1/2 15 Max. 20 50 75 30 60 100
Cat. No.
$ Price
Cat. No.
$ Price
3
SAFETY SWITCHES H362AWC Interlocked Receptacle Switch with Crouse-Hinds Arktite Receptacle H362AWH Interlocked Receptacle Switch with Hubbell Hubbellock Receptacle
Fusible3P, 600 Vac Maximum 30 H361WC 2139.00 H361DSWC 6377.00 H361AWC 2355.00 60 H362WC 2751.00 H362DSWC 7749.00 H362AWC 2846.00 100 H363WC 6005.00 H363DSWC 14826.00 H363AWC 6087.00 Non-Fusible3P, 600 Vac Maximum 30 HU361WC 1952.00 HU361DSWC 5888.00 HU361AWC 2136.00 60 HU362WC 2634.00 HU362DSWC 7374.00 HU362AWC 2678.00 100 HU363WC 5249.00 HU363DSWC 14025.00 HU363AWC 5444.00 d Std.Using fast acting one time fuses. Max.Using dual element time delay fuses.
Hubbellock Receptacle
UL Listed, suitable for use as service equipment. Short circuit rating: 10 kA.
Note: The Hubbellock receptacle switch utilizes the Square D interlocked plug SD12781 available only from Square D. Table 3.20:
NEMA 1 Amperes Cat. No. $ Price NEMA 12 Cat. No. $ Price Use with Plug Cat. No. $ Price Std. 15 Horsepower Ratings3e 480 Vac Max. 30 50 Std. 15 600 Vac Max. 50 60
Fusible3P, 600 Vac Maximum 60 H362WH 2351.00 H362AWH 2459.00 SD12781f 609.00 Non-Fusible3P, 600 Vac Maximum 60 HU362WH 2237.00 HU362AWH 2310.00 SD12781f 609.00 e Std.Using fast acting one time fuses. Max.Using dual element time delay fuses. f Hubbell plug is furnished with a Kellems grip for 1-1/2 in. to 1-21/64 in. cable diameter. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-11 through 3-13.
3-10
DE1
Discount Schedule
Accessories
RB Hub
$ Price Each 33.30 33.30 33.30 33.30 61.00 102.00 186.00 300.00 368.00 3.80 (DE1A) Note: NEMA 3R rainproof enclosures with Cat. No. ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. For more details see page 1-13. Hubs through size 2-12 can be directly installed on RB devices. Devices requiring three-inch or larger hubs must have holes cut in the field. Gaskets are provided on three-inch and larger hubs. Note: All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread.
Watertight Hubsfor use on NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures
Conduit Trade Size Standard-Zinc Hub Cat. No. Zinc $ Price Each Chrome Plated Hub Cat. No. Chrome Plated $ Price Each 1/2 H050 31.10 H050CP 40.70 3/4 H075 45.00 H075CP 56.00 1 H100 47.10 H100CP 64.00 1-1/4 H125 54.00 H125CP 67.00 1-1/2 H150 83.00 H150CP 96.00 2 H200 120.00 H200CP 137.00 2-1/2 H250 138.00 3 H300 177.00 3-1/2 H350 282.00 4 H400 381.00
Table 3.23:
Switch Rating Series Number Class R Fuse Kit $ Price Factory-Installed (A) (See pages 3-14, 3-15) Cat. No. $ Price 100 h F2F7 RFK10 47.70 231.00 200 F5F6 HRK1020 47.70 231.00 400600 E2E4 HRK4060 111.00 360.00 h See page 3-7 for Class R Fuse Kits in NEMA 4X Fiberglass Reinforced Polyester and Krydon switches. i The following Series F5F7 devices use RFK06: H3612, H3612A, H3612AWK, H3612RB, H461, H461DS, H461AWK, H361AWA and H361AWC.
SS10SK j
Skirt Kit to Enclose 100 A 9422 Switch NA 600 Vac 100 A (requires SS10) Requires arc shield on 240 V switches be changed to 600 V arc suppressor.
255.
Switch Rating Series Number Class R Fuse Kit (A) (See pages 3-14, 3-15) Cat. No. 30 F5F7 RFK03Lg 60 F1, F2, F3 RFK06 60 F4F7 RFK03H 100 F2F7 RFK10 200 F5F6 HRK1020 400600 E HRK4060 g H221-2AWK uses RFK06 Class R fuse kit.
Table 3.23:
Switch Rating (A) 30h 30 h 60 h
60 60 l 100 k l
30 A 4- and 6-pole, H361-2 and H361-2RB Series F5 use FPK0610. H362WA, H362WC, H362AWA, H362AWC, H362WH and H362AWH use FPK0610 fuse puller kit.
DE1
DE1A
Discount Schedule
3-11
SAFETY SWITCHES
Switch Rating Series Number Electrical Interlock Kit $ Price Factory-Installed (A) (See pages 3-14, 3-15) Cat. No.b $ Price EIK031c d F1, F5F7 218.00 359.00 EIK032c d 30 EIK1 F3 311.00 452.00 EIK2 EIK1 F1-F3 311.00 452.00 F5F7 (600 V) EIK2 60 EIK031e F4 218.00 359.00 F5F6 (240 V) EIK032e EIK1 100200 F2F7 311.00 452.00 EIK2 EIK40601 4001200 E1E4 533.00 674.00 EIK40602 a See page 3-7 for electrical interlocks on NEMA 4X fiberglass reinforced polyester and Krydon. b Electrical interlock kit catalog numbers with 1 suffix indicates one normally open and one normally closed contact; 2 indicates two normally open and two normally closed contacts. Kits are UL Listed. c HU461AWK uses EK3061 or EK3062. d The following Series F5F7 devices use EIK-1, 2: H3612, H3612A, H3612AWK, H3612RB, H461, H461DS, H461AWK, HU461, HU461DS, HU661DS, HU661AWK, H361AWA, H361AWC, HU361AWA and HU361AWC. e H362WA, HU362WA, H362WC, H362AWA, HU362AWA, H362AWC, HU362AWC, and H2212AWK use EIK1 or EIK2 electric interlock. f Single-pole single-throw interlock kits are rated 1/2 hp @ 110 and 220 Vac.
Safety Switch Application 9422 Type T (F Series Only) Disconnect Application $ Price 240 / 600 Vac 30 A Interior Barrier for 30 A SS03 NA 150. Safety Switchj 240 Vac 60 A Interior Barrier for 60 A 600 Vac 30 A SS06 Safety Switch, 30 or 600 Vac 60 A 165. 600 Vac 60 A 60 A 9422 Switch Interior Barrier for 100 A SS10 Safety Switch or 240 / 600 Vac 100 A 600 Vac 100 A 195. 100 A 9422 Switch Interior Barrier for 200 A SS20 240 / 600 Vac 200 A NA 225. Safety Switch Skirt Kit to Enclose 30 or 600 Vac 30 A SS0306SK 60 A 9422 Switch NA 225. 600 Vac 60 A (requires SS06) Cat. No. Description
Accessories
Class 3110 / Refer to Catalog 3100CT0701
www.schneider-electric.us
Neutral AssembliesField-Installed Neutral Assemblies for Fusible and Non-Fusible 240 and 600 Volt Safety Switches
Switch Series Number Rating (See pages 3-14, 3-15) (A) 30 F1, F5F6 F1F3, F5F6 (600 V) 60 F4, F5F6 (240 V) 100 200b 400 and 600 800 F2F6 F5F6 E1E4 E2E4 Standard Neutral Kit Cat. No. SN03a SN0610 SN03a SN0610 SN20A H600SN H800SNE4 Terminal Data AWG/kcmil (3) 2 Max. Al/Cu (2) 1/0 Max. Al/Cu (2) 6 Max. Al/Cu (3) 2 Max. Al/Cu (2) 1/0 Max. Al/Cu (2) 6 Max. Al/Cu (2) 250 Max. Al/Cu (1) 1/0 Max. Al/Cu (4) 750 Max. Al/Cu (1) 300 Max. Al/Cu Only $ Price Optional Copper No. Neutral Kit Cat. 83.00 107.00 83.00 107.00 200.00 327.00 753.00 1034.00 SN03C a SN0610C SN03Ca SN0610C SN20C H600SNC Terminal Data AWG/kcmil (3) 6 Max. Cu (2) 1/0 Max. Cu (2) 6 Max. Cu (3) 6 Max. Cu (2) 1/0 Max. Cu (2) 6 Max. Cu (2) 250 Max. Cu (1) 1/0 Max. Cu (2) 600 Max. Cu (2) 350 Max. Cu (1) 250 Max. Cu $ Price 102.00 114.00 102.00 114.00 246.00 452.00
(6) 750 Max. Al/Cu (2) 350 Max. Al/Cu (8) 750 Max. Al/Cu 1200 E2E4 H1200SNE4 (2) 350 Max. Al/Cu Note: Neutrals cannot be installed in 4P, 6P, or 200 A NEMA 4X fiberglass reinforced polyester safety switches. a The following Series F5F6 devices use SN0610(C): H-361-2, H-361-2RB, H-361-2A and H-361-2AWK. b For 200% neutral, order (2) neutral kits and (1) SN20NI neutral jumper kit. (2) 350 Max. Al/Cu.
suffix GL to standard Cat. No. (Example: H361GL). Price = Switch + Kit Price. NOTE: Kits are factory-installed standard in 30200 A series F NEMA 4-4X-5 (stainless) and 12, and in all NEMA 30200 A Series F 46P switches.
GTK0610 (2) 2/0 Max. Al/Cu PKOGTA2 (2) 2/0 Max. Al/Cu PKOGTA2e 400 and 600 E2E4 (2) 2/0 Max. Al/Cu (2 Required) 800 E2E4 PKOGTA7 (4) 350 Max. Al/Cu 1200 E2E4 PKOGTA8 (8) 350 Max. Al/Cu c The following Series F5F6 devices use GTK0610(C): H-361-2 and H-361-2RB. d 4- and 6-pole 30 A F Series. e Two required if grounding conductors are run in parallel. f PE1A Discount Schedule
3
SAFETY SWITCHES
Table 3.24:
Description 16 oz. Aerosol Paint Can, Square D Gray Paint Note: Shipped in quantities of 6.
Special Paint
UL Listed heavy duty switches are available painted with special safety colors. To order safety colored switches add suffixes as noted in Table 3.25 to the standard switch commercial reference number. All colors comply with OSHA Standard 1910.144 and ANSI Specification Z535.1 for marking physical hazards. Table 3.25:
Safety Color Black Red Orange Yellow Green Blue Purple Gray White
Safety Colors
Suffix SP0 SP2 SP3 SP4 SP5 SP6 SP7 SP8 SP9
LOGK2
45.00
177.00
For factory installation, add suffix LOG to the switch catalog number.
A minimum quantity of 10 is required. Not available for NEMA Type 7/9 or stainless steel products. Price Adder Each Switch
Quantity 10 $ Price 30 A 242.00 60 A 278.00 100 A 434.00 200 A 479.00 400 A 1137.00 600 A 2801.00 800 A 3501.00 1200 A 4376.00
3-12
DE1
PE1A
Discount Schedule
Switch Lug Kit Kit Factory-Installed (A) Cat. No.b $ Price Adder per Switch 30 CL0306F 69.00 224.00 60 CL0306F 69.00 224.00 100 CL10F 159.00 431.00 200 CL20F 264.00 717.00 400 CL40F 549.00 1490.00 600 CL60F 893.00 2426.00 800 1200 b One kit includes all phase line/load lugs for a 3-pole switch.
KI = 1 lock per switch KI2 = 1 lock with 2 cylinders (2 keys) per switch KIKI = 2 separate locks per switch
Table 3.26:
Al/Cu to Cu Only
Switch Type $ Price 301200 A Heavy Duty 2055.00 30600 A Double Throw 1988.00 Prices do not apply when more than three devices are interlocked, as these schemes normally require more than one key assembly per device.
Kit $ Priced
Lock-On Provisions
Lock-off provisions are standard on all heavy duty safety switches. Provision for one 38-inch hasp padlock is available factory-installed on NEMA 1, 3R, 4-4X-5 stainless steel and 12 switches. This modification will allow the switch to be locked in the ON position. UL Listed. Table 3.27: Price Adder Per Each Switch
Safety Switch Rating To order, add suffix SPLO to standard catalog number. Example: H364-SPLO 301200 A $ Price 155.00
200 AL20DTF 159.00 c Not UL Listed. d Kit contains 3 lugs. For double lugs for line and load, order 2 kits.
Switch wire range per phase and neutral AWG/kcmil (2) 6 250 Cu/Al
Switch Lug Kit Amperes Cat. No. 800 H8LKE2 1200 H12LKE2 Note: For terminal lug data, refer to table below.
Switch Lubricant
Field maintenance lubricant is available for servicing blade and jaw components in switches 600 V and below. Catalog number SWLUB (list price $24.14) consists of one tube of BG20 High Performance Synthetic Grease manufactured by Dow Corning, a material safety data sheet, and re-lubrication information. SWLUB is available in warehouse stock, shipped individually on in multiples of 12 units per carton. BG20 grease by Dow Corning is a high-performance synthetic grease which is biodegradable and has an operating temperature range from -50 F (-45C) to 360 F (180C). This temperature range exceeds normal operating conditions for switches as defined by NEMA. This grease has undergone extensive testing as a lubricant for maintaining blade and jaw areas in switches. Do not substitute any other lubricants.
Switch Amperes
System
2 Wire 800 3 Wire 4 Wire 2 Wire 1200 3 Wire 4 Wire Note: For terminal Lug data refer to table below.
Factory-Installed $ Price Adder Per Switch 2106.00 2972.00 3839.00 2591.00 3696.00 4806.00
Table 3.32:
Switch Amperes 800
1200
DE1
DE5
Discount Schedule
3-13
Table 3.31: Factory-Installed Series E4 800 and 1200 A safety switches are available with factoryinstalled VCEL-075-12H1 Versa-Crimp compression lug kits (above). For factory installation, add suffix LK to standard Cat. No. (Example: H367LK) and use price adder from table below based on system type.
SAFETY SWITCHES
800 and 1200 A Compression Lug Kits Field- Installed (See page 3-14 for 100600 A Switches) Series E4 800 and 1200 A safety switches are equipped as standard with mechanical lugs. Alternate compression lug kits are available for field installation and are UL Listed. Each kit consists of VCEL07512H1 Versa-Crimp Compression Lugs and lug landing connectors capable of converting line and load side of one switch pole or neutral. Order one field-installed kit per pole or neutral per table below. Example: Three-pole three-wire requires three kits; three-pole, four-wire requires four kits.
Table 3.30:
Table 3.33:
W W
Rating (A) 30c 60d 100 200e
W/H
W/H
Typical NEMA 1
Typical NEMA 3R
VCEL02114S1 VCEL030516H1 VCEL07512H1 1 1/0750 (Al/Cu)f 1/0750 (Al/Cu) or 400 or or and VCEL030516H1g 2 1/0300 (Al/Cu) 1/0300 (Al/Cu) and VCEL05012H1 600 2 3/0500 (Al/Cu) 3/0500 (Al/Cu) VCEL05012H1 800 3 3/0750 (Al/Cu) 3/0750 (Al/Cu) H8LKE2h 1200 4 3/0750 (Al/Cu) 3/0750 (Al/Cu) H12LKE2 h oC conductors. a 30100 A switches suitable for 60C or 75C conductors. 2001200 A switches suitable for 75 b For NEMA 1 and 3R only. c HU461AWK 146 AWG (Cu). d H60XFA 146 AWG (Cu). e H225XKA 4 AWG300 kcmil (Cu). f Max. wire range is (1) 600 kcmil or (2) 300 kcmil Al/Cu on NEMA 4X Stainless and NEMA 12. g Order two PK516KN mounting kits when installing VCEL030516H1 lugs. Only one kit is required on 2-Pole switches. h See page 3-13, 800 and 1200 A compression lug kits for additional information. Approximate Dimensions D W/H mm 124 124 124 124 162 162 210 216 257 242 257 242 451 451 451 451 257 242 257 242 451 451 451 451 124 124 124 124 162 162 210 216 257 242 257 242 451 451 451 451 124 162 124 173 173 162 162 173 178 173 162 162 173 173 in. 7.55 7.55 7.55 7.55 10.50 10.50 18.50 18.63 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 7.55 7.55 7.55 7.55 10.50 10.50 18.50 18.63 27.88 27.88 27.63 27.88 36.62 36.62 36.62 36.62 7.55 10.50 7.55 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 mm 192 192 192 192 267 267 470 473 702 708 702 708 930 930 930 930 702 708 702 708 930 930 930 930 192 192 192 192 267 267 470 473 708 708 702 708 930 930 930 930 192 267 192 267 267 267 267 267 267 267 267 267 267 267 Cat. No. H364, N H364RB, NRB H365, N H365R, NR H366, N H366NR, R H367, N H367NR, R H368, N H368NR, R H461 H462 H463 H464 H465 H466 HU265 HU265R HU266 HU266R HU267 HU267R HU268 HU268R HU361 HU361RB HU361WA HU361WC HU362 HU362RB HU362WA HU362WC HU362WH HU363 HU363RB HU363WA HU363WC HU364 HU364RB HU365 HU365R HU366 HU366R HU367 HU367R HU368 HU368R HU461 HU462 HU463 HU464 HU465 HU466 Series F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F5 E4 E4 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F6 F6 F5 F5 F6 F6 F5 F5 F5 F6 F6 F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F5 E4 E4 H in. 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 20.50 20.50 20.50 29.00 50.25 50.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 14.60 14.88 18.19 18.19 17.50 17.50 18.19 16.75 18.19 21.25 21.25 21.85 21.85 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 20.50 20.50 20.50 29.00 50.25 50.25 mm 737 743 1276 1278 1276 1278 1756 1756 1756 1756 521 521 521 737 1276 1276 1276 1278 1276 1278 1756 1756 1756 1756 371 378 462 462 445 445 462 425 462 540 540 462 555 737 743 1276 1278 1276 1278 1756 1756 1756 1756 521 521 521 737 1276 1276 in. 17.13 17.25 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 14.75 14.75 14.75 23.25 33.88 33.88 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 6.50 6.63 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 8.50 9.00 9.00 17.13 17.25 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 14.75 14.75 14.75 23.25 33.88 33.88 W mm 435 438 702 705 702 705 930 930 930 930 375 375 375 591 861 861 702 705 702 705 930 930 930 930 165 168 229 229 229 229 229 229 229 216 216 229 229 435 438 702 705 702 705 930 930 930 930 375 375 375 591 861 861 in. 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 6.85 6.85 6.85 8.75 10.13 10.13 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 4.88 4.88 6.81 6.81 6.38 6.38 6.81 7.00 6.81 6.38 6.38 6.81 6.81 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 6.85 6.85 6.85 8.75 10.13 10.13 D mm 210 216 257 242 257 242 451 451 451 451 174 174 174 222 257 257 257 242 257 242 451 451 451 451 124 124 173 173 162 162 173 178 173 162 162 173 173 210 216 257 242 257 242 451 451 451 451 174 174 174 222 257 257 W/H in. 18.50 18.63 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 16.13 16.13 16.13 24.88 33.88 33.88 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 7.55 7.55 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 18.50 18.63 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 16.13 16.13 16.13 24.88 33.88 33.88 mm 470 473 702 708 702 708 930 930 930 930 410 410 410 632 861 861 702 708 702 708 930 930 930 930 192 192 267 267 267 267 267 267 267 267 267 267 267 470 473 702 708 702 708 930 930 930 930 410 410 410 632 861 861
Approximate Dimensions Cat. No. H221N H221NRB H222N H222NRB H223N H223NRB H224N H224NRB H225, N H225NR, R H226, N H226NR, R H227, N H227NR, R H228, N H228NR, R H265 H265R H266 H266R H267 H267R H268 H268R H321N H321NRB H322N H322NRB H323N H323NRB H324N H324NRB H325, N H325R, NR H326, N H326R, NR H327, N H327R, NR H328, N H328R, NR H361, N H361-2 H361NRB, RB H361WA H361WC H362, N H362NRB, RB H362WA H362WC H362WH H363, N H363NRB, RB H363WA H363WC Series F5 F5 F5 F5 F5 F5 F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F5 F5 F5 F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F6 F6 F5 F5 F6 F6 F5 F5 F5 F6 F6 H in. 14.60 14.88 14.60 14.88 21.25 21.25 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 14.60 14.88 14.60 14.88 21.25 21.25 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 14.60 17.50 14.88 18.19 18.19 17.50 17.50 18.19 16.75 18.19 21.25 21.25 21.85 21.85 mm 371 378 371 378 540 540 737 743 1276 1278 1276 1278 1756 1756 1756 1756 1276 1278 1276 1278 1756 1756 1756 1756 371 378 371 378 540 540 737 743 1276 1278 1276 1278 1756 1756 1756 1756 371 445 378 462 462 445 445 462 425 462 540 540 462 555 in. 6.50 6.63 6.50 6.63 8.50 8.50 17.13 17.25 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 6.50 6.63 6.50 6.63 8.50 8.50 17.13 17.25 27.88 27.76 27.63 27.76 36.62 36.62 36.62 36.62 6.50 9.00 6.63 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 8.50 9.00 9.00 W mm 165 168 165 168 216 216 435 438 702 705 702 705 930 930 930 930 702 705 702 705 930 930 930 930 165 168 165 168 216 216 435 438 708 705 702 705 930 930 930 930 165 229 168 229 229 229 229 229 229 229 216 216 229 229 in. 4.88 4.88 4.88 4.88 6.38 6.38 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 4.88 4.88 4.88 4.88 6.38 6.38 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 4.88 6.38 4.88 6.81 6.81 6.38 6.38 6.81 7.00 6.81 6.38 6.38 6.81 6.81
3
SAFETY SWITCHES
3-14
Approximate Dimensions Cat. No. H362DSWA H362DSWC H362DF H362DX H362SS H363AWA H363AWC H363AWK, A H363DS H363DSWA H363DSWC H363DF H363DX H363SS H364A,AWK H364DS,NDS H364NA,NAWK H364DF H364SS H365AWK, DS H365NAWK, NDS H366AWK, DS H366NAWK, NDS H367AWK, NAWK H368AWK, NAWK H461AWK H461DS H462AWK H462DS H463AWK H463 DS H464AWK H464DS H465AWK H663AWK H663DS H664AWK H664DS HU265AWK, DS HU266AWK, DS HU267AWK HU268AWK HU361AWA HU361AWC HU361AWK, A HU361DS HU361DSWA HU361DSWC HU361DF HU361DX HU361SS HU362AWA HU362AWC HU362AWH HU362AWK, A HU362DS HU362DSWA HU362DSWC HU362DF HU362DX HU362SS HU363AWA HU363AWC HU363AWK, A HU363DS HU363DSWA HU363DSWC HU363DF HU363DX HU363SS HU364A,AWK HU364DF HU364DS HU364SS HU365AWK, DS HU366AWK, DS HU367AWK HU368AWK HU461AWK HU461DS HU462AWK HU462DS HU463AWK HU463DS HU464AWK HU464DS HU465AWK HU661AWK HU661DS HU662AWK HU662DS HU663AWK HU663DS HU664AWK HU664DS Series F7 F7 F1 F1 F6 F7 F7 F6 F6 F7 F7 F1 F1 F6 F6 F6 F6 E1 F6 E4 E4 E4 E4 E4 E4 F6 F6 F6 F6 F6 F6 F6 F6 E4 F6 F6 F6 F6 E4 E4 E4 E4 F7 F7 F6 F6 F7 F7 F1 F1 F6 F7 F7 F6 F6 F6 F7 F7 F1 F1 F6 F7 F7 F6 F6 F7 F7 F1 F1 F6 F6 E1 F6 F6 E4 E4 E4 E4 E1 F6 F6 F6 F6 F6 F6 F6 E4 F6 F6 F6 F6 F6 F6 F6 F6 H in. 16.87 16.87 16.50 19.40 16.87 20.50 20.50 20.50 20.82 20.82 20.82 24.80 25.25 20.82 29.00 29.00 29.00 31.30 29.00 46.25 46.25 46.25 46.25 69.13 69.13 20.50 20.82 20.50 20.82 20.50 20.82 29.00 29.00 46.25 20.50 20.82 29.00 29.00 46.25 46.25 69.13 69.13 16.50 16.50 14.60 14.93 16.87 16.87 16.50 19.40 14.93 16.50 16.50 16.50 16.50 16.87 16.87 16.87 16.50 19.40 16.87 20.50 20.50 20.50 20.82 20.82 20.82 24.80 25.25 20.82 29.00 31.30 29.00 29.00 46.25 46.25 69.13 69.13 16.63 20.82 20.50 20.82 20.50 20.82 29.00 29.00 46.25 20.50 20.82 20.50 20.82 20.50 20.82 29.00 29.00 mm 428 428 419 493 428 521 521 521 529 529 529 630 641 529 737 737 737 795 737 1175 1175 1175 1175 1756 1756 521 529 521 529 521 529 737 737 1175 521 529 737 737 1175 1175 1756 1756 419 419 371 379 428 428 419 493 379 419 419 419 419 428 428 428 419 493 428 521 521 521 529 529 529 630 641 529 737 795 737 737 1175 1175 1756 1756 422 529 521 529 521 529 737 737 1175 521 529 521 529 521 529 737 737 W in. 8.92 8.92 11.00 11.40 8.92 9.00 9.00 9.00 9.36 9.36 9.36 13.70 11.40 9.36 17.25 17.75 17.25 26.30 17.75 26.25 26.25 26.25 26.25 36.62 36.62 14.75 15.08 14.75 15.08 14.75 15.08 23.25 23.75 32.50 14.75 15.08 23.25 23.75 26.25 26.25 36.62 36.62 9.00 9.00 6.63 7.22 8.92 8.92 11.00 11.40 7.22 9.00 9.00 9.00 9.00 8.92 8.92 8.92 11.00 11.40 8.92 9.00 9.00 9.00 9.36 9.36 9.36 13.70 11.40 9.36 17.25 26.30 17.75 17.75 26.25 26.25 36.62 36.62 9.88 15.08 14.75 15.08 14.75 15.08 23.25 23.75 32.50 14.75 15.08 14.75 15.08 14.75 15.08 23.25 23.75 mm 227 227 279 290 227 229 229 229 238 238 238 348 290 238 438 451 438 668 451 667 667 667 667 930 930 375 383 375 383 375 383 591 603 826 375 383 591 603 667 667 930 930 229 229 168 183 227 227 279 290 183 229 229 229 229 227 227 227 279 290 227 229 229 229 238 238 238 348 290 238 438 668 451 451 667 667 930 930 251 383 375 383 375 383 591 603 826 375 383 375 383 375 383 591 603 D in. 5.11 5.11 8.80 8.60 6.97 7.00 7.00 7.00 6.97 6.97 6.97 12.00 8.60 6.97 8.75 8.88 8.75 11.80 8.88 10.13 10.13 10.13 10.13 17.75 17.75 6.80 6.97 6.80 6.97 6.80 6.97 8.75 8.88 10.13 6.80 6.97 8.75 8.88 10.13 10.13 17.75 17.75 7.00 7.00 4.96 5.11 5.11 5.11 8.80 8.60 5.11 7.00 7.00 7.00 7.00 6.97 5.11 5.11 8.80 8.60 6.97 7.00 7.00 7.00 6.97 6.97 6.97 12.00 8.60 6.97 8.75 11.80 8.88 8.88 10.13 10.13 17.75 17.75 6.13 6.97 6.80 6.97 6.80 6.97 8.75 8.88 10.13 6.80 6.97 6.80 6.97 6.80 6.97 8.75 8.88 mm 130 130 224 218 177 178 178 178 177 177 177 305 218 177 216 226 216 300 226 259 259 259 259 451 451 173 177 173 177 173 177 222 226 259 173 177 222 226 259 259 451 451 178 178 125 130 130 130 224 218 130 178 178 178 178 177 130 130 224 218 177 178 178 178 177 177 177 305 218 177 216 300 226 226 259 259 451 451 156 177 173 177 173 177 222 226 259 173 177 173 177 173 177 222 226 W/H in. 10.81 10.79 11.00 11.40 10.81 10.50 10.50 10.50 11.25 11.25 11.25 13.70 11.40 11.25 18.63 19.25 18.63 26.30 19.25 26.25 26.25 26.25 26.25 36.62 36.62 16.13 16.85 16.13 16.85 16.13 16.85 24.88 25.25 32.50 16.13 16.85 24.88 25.25 26.25 26.25 36.62 36.62 10.50 10.50 7.55 8.67 10.81 10.79 11.00 11.40 8.67 10.50 10.50 10.50 10.50 10.81 10.81 10.79 11.00 11.40 10.81 10.50 10.50 10.50 11.25 11.25 11.25 13.70 11.40 11.25 18.63 26.30 19.25 19.25 26.25 26.25 36.62 36.62 11.00 16.85 16.13 16.85 16.13 16.85 24.88 25.25 32.50 16.13 16.85 16.13 16.85 16.13 16.85 24.88 25.25 mm 275 274 279 290 275 267 267 267 286 286 286 348 290 286 473 489 473 668 489 667 667 667 667 930 930 410 428 410 428 410 428 632 641 826 410 428 632 641 667 667 930 930 267 267 192 220 275 274 279 290 220 267 267 267 267 275 275 274 279 290 275 267 267 267 286 286 286 348 290 286 473 668 489 489 667 667 930 930 279 428 410 428 410 428 632 641 826 410 428 410 428 410 428 632 641
W/H D Typical NEMA 4X Typical NEMA 4, 4X, 5, 12, Fiberglass Reinforced 12K (Stainless has flat front) Polyester and Krydon
Typical NEMA 7, 9
Table 3.34:
(See page 3-13 for pricing. See page 3-14 for terminal lug data for the series switches listed in the dimension table below.) Rating (A) Optional Lug Kit Cat. No.a Lug Wire Range Per Phase AWG/kcmil 3060 CL0306F (1) 148 Cu solid or 144 Cu strand 100 CL10F (1) 148 Cu solid or 141/0 Cu strand 200 CL20F (1) 6250 Cu 400 CL40F (1) 1600 Cu plus (1) 6250 Cu 600 CL60F (2) 4350 Cu a One kit includes all phase line/load lugs for a 3-pole switch.
Table 3.35:
Rating (A)
Conduit Provisions
Top and Bottom Endwall NEMA 7 and 9c 3/4 in. 1-1/4 in. 2-1/2 in.
b c
NEMA 4X Fiberglass Reinforced Polyester and Krydonb 30 3/4 in. 60 1-1/4 in. 100 2 in. 200 2-1/2 in. Hubs and hub drilling templates are provided for field-installation. Threaded conduit opening. Approximate Dimensions Cat. No. Series E1 E1 F6 F6 F6 F6 F6 F6 F6 F6 F6 E4 E4 C2 E4 E4 E4 E4 E4 E4 E4 E4 F6 F6 F6 F6 F6 F6 F6 F6 E4 E4 E4 E4 E4 E4 F7 F7 F6 F6 F7 F7 F1 F1 F6 F6 F7 F7 F6 F6 F6 H in. 15.93 15.93 14.60 14.93 16.50 14.60 14.93 20.50 20.82 29.00 29.00 46.25 46.25 22.56 46.25 46.25 69.13 69.13 46.25 46.25 69.13 69.13 14.60 14.93 14.60 14.93 20.50 20.82 29.00 29.00 46.25 46.25 46.25 46.25 69.13 69.13 16.50 16.50 14.60 14.93 16.87 16.87 16.50 19.40 14.93 16.50 16.50 16.50 16.50 16.50 16.87 mm 405 405 371 379 419 371 379 521 529 737 737 1175 1175 573 1175 1175 1756 1756 1175 1175 1756 1756 371 379 371 379 521 529 737 737 1175 1175 1175 1175 1756 1756 419 419 371 379 428 428 419 493 379 419 419 419 419 419 428 W in. 9.87 9.87 6.63 7.22 9.00 6.63 7.22 9.00 9.36 17.25 17.75 26.25 26.25 10.88 26.25 26.25 36.62 36.62 26.25 26.25 36.62 36.62 6.63 7.22 6.63 7.22 9.00 9.36 17.25 17.75 26.25 26.25 26.25 26.25 36.62 36.62 9.00 9.00 6.63 7.22 8.92 8.92 11.00 11.40 7.22 9.00 9.00 9.00 9.00 9.00 8.92 mm 251 251 168 183 229 168 183 229 238 438 451 667 667 276 667 667 930 930 667 667 930 930 168 183 168 183 229 238 438 451 667 667 667 667 930 930 229 229 168 183 227 227 279 290 183 229 229 229 229 229 227 D in. 6.96 6.96 4.96 5.11 7.00 4.96 5.11 7.00 6.97 8.75 8.88 10.13 10.13 7.75 10.13 10.13 17.75 17.75 10.13 10.13 17.75 17.75 4.96 5.11 4.96 5.11 7.00 6.97 8.75 8.88 10.13 10.13 10.13 10.13 17.75 17.75 7.00 7.00 4.96 5.11 5.11 5.11 8.80 8.60 5.11 7.00 7.00 7.00 7.00 7.00 6.97
W/H mm 177 177 125 130 178 125 130 178 177 216 226 259 259 197 259 259 451 451 259 259 451 451 125 130 125 130 178 177 216 226 259 259 259 259 451 451 178 178 125 130 130 130 224 218 130 178 178 178 178 178 177 in. 9.87 9.87 7.55 8.67 10.50 7.55 8.67 10.50 11.25 18.63 19.25 26.25 26.25 10.88 26.25 26.25 36.62 36.62 26.25 26.25 36.62 36.62 7.55 8.67 7.55 8.67 10.50 11.25 18.63 19.25 26.25 26.25 26.25 26.25 36.62 36.62 10.50 10.50 7.55 8.67 10.81 10.79 11.00 11.40 8.67 10.50 10.50 10.50 10.50 10.50 10.81 mm 251 251 192 220 267 192 220 267 286 473 489 667 667 276 667 667 930 930 667 667 930 930 192 220 192 220 267 286 473 489 667 667 667 667 930 930 267 267 192 220 275 274 279 290 220 267 267 267 267 267 275
H60XFA H100XFA H221AWK, A H221DS H221-2AWK H222AWK, A H222DS H223AWK, A H223DS H224A,AWK H224DS H225AWK, DS H225NAWK, NDS H225XKA H226AWK, DS H226NAWK, NDS H227AWK, NAWK H228AWK, NAWK H265AWK, DS H266AWK, A, DS H267AWK, NAWK H268AWK, NAWK H321AWK, A H321DS H322AWK, A H322DS H323AWK, A H323DS H324A,AWK H324DS H325AWK, DS H325NAWK, NDS H326AWK, DS H326NAWK, NDS H327AWK, NAWK H328AWK, NAWK H361AWA H361AWC H361AWK, A H361DS H361DSWA H361DSWC H361DF H361DX H361SS H361-2AWK, A H362AWA H362AWC H362AWH H362AWK, A H362DS
3-15
SAFETY SWITCHES
30100 A Types DT, DTU (Series F) Fusible (DT) and non-fusible (DTU) switches available Manually-operated switch suitable for use in accordance with article 702 of the NEC, ANSI/NFPA 70 Standards: UL 98, NEMA KS1, CSA, and NOM Modular designswitch handle, lock-plate, switch mechanism; line and load bases are field replaceable UL Listed short circuit current ratings up to 200 kA (using Class R, J, or T fusessee table for rating) Load make/break rated Meets NEMA hp ratings Dual cover interlock May be padlocked ON (I) or OFF (O) Lock-off accepts up to three padlocks Side-opening door Quick make / quick break mechanism Meets NEMA requirements as heavy duty switch Field-installed electrical interlock kits Field-installed neutral assembly kits (2P and 3P switches) UL Listed as suitable for use as service equipment Supplied as standard for switching one load between two power sources, and may be field-converted to switch on power
source between two loads.
30 (Series T4), 200600 A Types 82,000 and 200 A DTU (Series E, A) Non-fusible Designed for manual transfer of loads from one supply to another UL Listed switches are suitable for use in accordance with Article 702 of the National Electrical Code, ANSI / NFPA 70 All 82,000 and DTU double throw switches are continuous duty rated for their nameplate ampere rating The 82,000 and DTU (Series E, A) switches are load make/break rated UL Listed as suitable for use as service equipment Horsepower rated only as footnoted.
Field-Installed Accessories:
Neutral Electrical Interlock Grounding Terminals
3
SAFETY SWITCHES 30100 A DT, DTU (Series F) NEMA 1 82,000 Line NEMA 1
3-16
240 Volt
Class 3140 / Refer to Catalog 3100CT0701
Horsepower Ratings ab System Rating (A) Current Series NEMA 1 Cat. No. $ Price NEMA 3R Cat. No. $ Price NEMA 4,4X,5 304 Stainless Steel Cat. No. $ Price NEMA 12 Gasketed Std. Cat. No. $ Price 1 3 1 240 Vac Max. 3 250 Vdcc
Table 3.36:
Line
100
DT223
2379.00
DT223RB
3056.00
7.5
15 d
15
30 d
20
Line
Load
3P, 240 Vac250 Vdc
Line
30 60
F F
DT321 DT322
1646.00 1970.00
DT321RB DT322RB
2216.00 2612.00
1.5 e 3e
3d 7.5 d
3e 10 e
7.5 d 15 d
5 10
Line
100 F DT323 3104.00 DT323RB 3725.00 7.5 e 15 d 15 e 30 d 20
Load
Table 3.37:
Line
Line Load
60 100
F F
DTU222 DTU223
962.00 1371.00
DTU223RB
1347.00
10 15
10 f 20 f
T4 E A
2177.00 8715.00
H82254 H82255 g
4671.00 10335.00
15 15
Line
Line Load
30 60 100
F F F
DTU323RB
1953.00
3d
5e 10 e 15 e
10 d 15 d 30 d
5f 10 f 20 f
30 200 200 400 600 4P, 240 Vac 30 200 400 600 a b c d e f g h i j k
T4 E E A A T4 E A A
687.00 2564.00 DTU324NRB gh 3005.00 2798.00 8040.00 82355R gk 13038.00 12555.00 DTU326R 13890.00 953.00 5184.00 11505.00 20355.00 82454R k 82455R DTU426R 7517.00 16200.00 20595.00
15 15 125 15 j 125
50 50
Refer to page 7-31 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics. Std.Using fast acting one time fuses. Max.Using dual element time delay fuses. For switching dc, use two switching poles. If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors. Use outer switching poles. Maximum rating. 240 Vac only. Neutral included with device. Suitable for use as service equipment. Hp rating applies only to H82454. 250 V dc rated.
600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-18 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 Dimensions: 30100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . page 3-21 Dimensions: 30, 200600 A (Series E, T4, A) . . . . . . . . . . . . . . . page 3-22
DE1
Discount Schedule
3-17
SAFETY SWITCHES
600 Volt
Class 3140 / Refer to Catalog 3100CT0701
www.schneider-electric.us
Table 3.38:
System
Line
Line
30 60 100
F F F
5 15 25
15 30 60
7.5 15 30
20 50 75
15 30 50
Load
Non-Fusible 3P, 600 Vac600 Vdc 1 d 3 b 1 d 3 b 1 d 3
Line
Line Load
30 60 100
F F F
DTU362DS DTU363DS
5 10 20
10 20e 40h
7.5 25 40
20 50 g 75 hi
10 30 40
30 60 g 75 h
5 10 20
15 30 50
E A A
5868.00 82344DSjr 11415.00 H82344ljq 7503.00 13140.00 82345DS nm 15675.00 H82345 12105.00 19800.00 DTU366AWKn 21675.00
125 3
15 k 250 3
350 3
50
Line
Line Load
60 100
F F
DTU462 DTU463
DTU462DS DTU463DS
20 30
20 40
40 50
50 75
50 50
60 75
10 20
30 30
3
SAFETY SWITCHES
a b c d e f g h
E A A
125 3
250 3
350 3
50
Line
Line Load
60 100
F F
20 40
50 75
60 75
10 20
30 50
Refer to page 7-31 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics. If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors. For switching dc, use two switching poles. Use outer switching poles. Maximum Hp is 15 for corner grounded delta systems. Maximum Hp is 30 for corner grounded delta systems. Use 75oC #4 Cu or #2 Al conductors only. Use 75oC #1 Cu conductors only.
i j k l m n o p q r
Maximum Hp is 60 for corner grounded delta systems. 480 Vac maximum only, 250Vdc. Standard Hp rating. Not suitable for use as service equipment. 600 Vac max. 250 V dc rated. Std.Using fast acting one time fuses. Max.Using dual element time delay fuses. (Non-fusible switches have max rating unless noted.) Complete rating on switch is NEMA 3R or 12. For 3R applications, remove drain screw from bottom endwall. H82 ... and H92 ... devices are NEMA 12 only, intended for use indoors only. Not UL Listed. page 3-17 page 3-19 page 3-20 page 3-21 page 3-22
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions: 30100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions: 30, 200600 A (Series E, T4, A) . . . . . . . . . . . . . . . .
3-18
DE1
Discount Schedule
Accessories
Class 3140 / Refer to Catalog 3100CT0701
Table 3.38:
Neutral Assembly
Switch
Field-Installed Terminal Field-Installed Terminal Standard Neutral Kit Data $ Price Copper only Data $ Price Cat. No. AWG/kcmil Neutral Kit Cat. No. AWG/kcmil 30100 A Type DT, DTU (Series F) (2- and 3-pole switches only) SN0310 141/0 Al/Cu 114.00 SN0310C 141/0 Cu 120.00 30 A (Series T4) (2- and 3-pole switches only) a a 908.00 200 A Type 82000 and DTU (Series E) b a a 1110.00 (1) 4600kcmil or 105.00 400 A Type 82000 DT400N (2) 1/0250kcmil 600 A Type DTU (Series A) DT600NKD 250500kcmil 452.00 a For Type 82,000 switches, neutral is available factory-installed on 2P and 3P double throw switches. Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of the switch. For DTU switches, neutral is factory-installed in standard device and is UL Listed. b Neutral assembly catalog number DT200N can be added to 4P Type 82000 switches in the field.
Table 3.39:
Electrical Interlocks (For Electrical Interlock Contact Ratings, see Supplemental Digest page 2-4.)
Switch
Factory-Installed Field-Installed Electrical Interlock Kit Cat. No. c $ Price $ Price Adder Per Switch 30100 A Type DT, DTU (Series F) EIK1, EIK2 d 311.00 905.00e 200 A Type 82000 and DTU (Series E) f g 1113.00e 400 A Type 82000 EK400DTU2 260.00 600 A Type DTU (Series A) DS200EK2D 438.00 c Electrical interlock kit catalog numbers with 1 suffix indicate one normally open and normally closed contact; 2 indicates two normally open and two normally closed contacts. See page 3-11 for electrical interlock ratings. d 30100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will accept an electrical interlock. Some applications may therefore require (2) electrical interlocks. e 30100 A Type DT, DTU (Series F) switches with factory-installed electrical interlocks installed are UL Listed and interlocks are furnished with 2 N.O. /2 N.C. contacts installed in both ON positions. To order, add suffix EI to standard catalog number. f Electrical interlock EK400DTU2 can be added to 4-pole Type 82000 switches in the field. g Type 82000 and DTU switches are available with electrical interlock factory-installed only. Not UL listed. Electrical interlocks are furnished with 2 N.O./N.C. contacts and are installed in both ON positions. To order, add suffix EI to standard switch catalog number.
Table 3.40:
30100 A Type DT, DTU (Series F) 30 A Type 92,000 200 A Type 82000 and DTU (Series E) 400 A Type 82000 600 A Type 82000 (Series A)
Table 3.41:
Switch
When installed, this kit rejects all but Class R fuses. Kits are available for field installation. For factory installation, add CLR suffix to catalog number.
Key Interlock Systems For factory-installed key interlocks, refer to page 3-13. Phenolic Legend Plate For factory-installed phenolic legend plates, refer to Supplemental Digest page 2.4. Lock-On ProvisionsUL Listed 30100 A type DT, DTU (Series F) and type 92,000 included on standard device. Type 82,000 and 200 A DTU (Series E) available factory-installed. Add SPLO to catalog number and add $410. to list price. Table 3.42: Rainproof Bolt-On Hubsfor use on NEMA 3R Enclosures
3/4 B075 1 B100 1-1/4 B125 1-1/2 B150 2 B200 2-1/2 B250 3 B300 3-1/2 B350 4 B400 Closing Cap BCAP
Conduit Size
RB Hub
$ Price Eachh 33.30 33.30 33.30 33.30 61.00 102.00 186.00 300.00 368.00 3.80 Note: NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. For more details see page 1-13. Hubs through size 2-1/2 in. can be directly installed on RB devices. Devices requiring 3 in. or larger hubs must have holes cut in the field. Gaskets are provided on 3 in. and larger hubs. Note: All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. h See Discount Schedule.
Table 3.43:
Watertight Hubsfor use on NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures
1/2 H050 31.10 H050CP 40.70 3/4 H075 45.00 H075CP 56.00 1 H100 47.10 H100CP 64.00 1-1/4 H125 54.00 H125CP 67.00 1-1/2 H150 83.00 H150CP 96.00 2 H200 120.00 H200CP 137.00 2-1/2 H250 138.00 3 H300 177.00 3-1/2 H350 282.00 4 H400 381.00
Conduit Trade Size Standard-Zinc Hub Cat. No. Zinc $ Price Each Chrome Plated Hub Cat. No. Chrome Plated $ Price Each
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-17 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-18 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-20 Dimensions: 30100 A (Series F). . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-21 Dimensions: 30, 200600 A (Series E, T4, A) . . . . . . . . . . . . . . . . .page 3-22
DE1
DE1A
Discount Schedule
3-19
SAFETY SWITCHES
Class R Fuse Kits240 V (two kits per 3P switch) 30 A F5 60 A F5 100 A F5 Class R Fuse Kits600 V (two kits per 3P switch) 30 A F5 60 A F5 100 A F5
Application Data
Class 3140 / Refer to Catalog 3100CT0701
www.schneider-electric.us
Situations Requiring Fuses 30100 A Type DT (Series F): Select DT switches from pages 3-17, 3-18, which have provisions for accepting fuses. 30 A, 200600 A Type 82,000 (Series E, T4, A), all DTU devices: Use the non-fusible double throw switches from pages 3-17, 3-18 in conjunction with standard fusible devices, and install them according to diagram 1 or 2, below.
Line Non-Fusible Double Throw Switch Line
Table 3.44:
Switch Type Type DT (Series F) Type DTU b (Series F) DTU224NRB and DTU324NRB (Series E) DTU324N (Series E)
H, K 10,000 c R, J 100,000 H, K 10,000 c 240 V Type 82,000 all R, J 100,000 d 600 V H, K 10,000 c H, K 10,000 Type DTU (A series) 600 A 240 V or 600 V R, J, T 100,000 a Rating applies to AC only. The UL Listed short circuit current rating for non-fusible switches is based on the switch being used in conjunction with the corresponding fuse type. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed. b The DTU361 and DTU361RB are also suitable for use on a circuit capable of delivering not more than (A) 18 kA, 600 Vac maximum when protected by Type FH circuit breaker rated 30 A maximum or (B) 14 kA, 600 Vac maximum when protected by Type FA circuit breaker rated 30 A maximum. c Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used ahead of a non-fusible safety switch when there is up to 10 kA short circuit current available. d 400 A 82,000 switch is only 10 kA.
Table 3.45:
Switch
Terminal Lug Data for Type DT, DTU (Series F) Double Throw Safety Switches
Wires per Phase NEMA 1, 3R, 4, 4X, 12 Standard Lug Wire Range AWG/kcmil 122 Al or 142 Cu 121/0 Al or 141/0 Cu Optional Compression Lug Field-Installed C10-14, D8-14, or E6-14 e VCEL02114S1 f Optional Copper Only Lug
Wire Range Wire Bending Space Per NEC Table 373-6 AWG/kcmil 3060 A 122 Al Type DT, DTU 1 or (Series F) 142 Cu 100 A 121/0 Al Type DT, DTU 1 or (Series F) 141/0 Cu e Thomas and Betts catalog numbers. f Hubbell Versa-Crimp catalog numbers.
See pages 3-13 and 3-15 for appropriate kit. Order two kits per switch.
Table 3.46:
Load
Terminal Lug Data for Types 82,000 and for A and E-Series DTU devices
Switch Wires per Phase 1 Wire Range Wire Bending Space Per NEC Table 373-6 AWG/kcmil 148 Al/Cu 6300 Al/Cu 1/0600 Al/Cu or 1/0300 Al/Cu 250500 Al/Cu Lug Wire Range AWG/kcmil 122 Al or 142 Cu 6300 Al/Cu 1/0600 Al/Cu 250500 Al/Cu
Diagram 1
30 A (Series T4) h
Line Fusible Single Throw Switch or Circuit Breaker Non-Fusible Double Throw Switch Fusible Single Throw Switch or Circuit Breaker Line
1 1 or 2 600 2 o 200600 A switches suitable for 75 C conductors. 30 A switches suitable for 60oC or 75oC conductors. Hubbell Versa-Crimp catalog numbers. 400 200
3
SAFETY SWITCHES Load
g h i
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Dimensions: 30100 A (Series F). . . . . . . . . . . . . . . . . . . . . . . . . . page 3-21 Dimensions: 30, 200600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-22
Diagram 2
3-20
DE1
Discount Schedule
DimensionsSeries F Devices
Class 3140 / Refer to Catalog 3100CT0701
Table 3.47:
Cat. No. DT223 DT223RB DT321 DT321RB DT322 DT322RB DT323 DT323RB DT361 DT361RB DT362 DT362RB DT363 DT363RB DTU222 DTU223 DTU223RB DTU321 DTU322 DTU323 DTU323RB DTU361 DTU361RB DTU362 DTU362AWK DTU362DS DTU362RB DTU363 DTU363AWK DTU363DS DTU363RB DTU462 DTU462AWK DTU462DS DTU463 DTU463AWK DTU463DS DTU662AWK DTU663AWK
W/H
NEMA 1
W
W/H
NEMA 3R
W/H
3-21
SAFETY SWITCHES
240 V Double Throw. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 Dimensions: 30, 200600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-22
Table 3.48:
30, 200600 A Types 82,000 and E-Series DTU devices, NEMA 1 and 3RApproximate Dimensions
Series E1 E1 E1 E2 E1 E1 T4 E1 E1 E1 E2 E2 E3 E3 E3 E3 E3 E3 E3 E3 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 H in. 32.50 30.88 30.88 30.88 32.50 30.88 10.00 30.88 32.50 32.50 32.50 32.50 32.50 38.00 38.00 38.00 38.00 32.50 32.50 38.00 38.50 39.00 38.50 39.00 39.00 38.50 39.00 38.50 39.00 38.50 39.00 39.00 39.00 39.00 39.00 39.00 63.31 63.31 63.31 63.31 63.76 63.76 63.76 63.76 63.76 mm 826 784 784 784 826 784 254 784 826 826 826 826 826 965 965 965 965 826 826 965 978 991 978 991 991 978 991 978 991 978 991 991 991 991 991 991 1608 1608 1608 1608 1619 1619 1619 1619 1619 in. 20.63 15.75 20.00 20.00 20.63 20.00 8.00 20.00 24.50 24.50 24.50 30.21 30.21 29.62 29.62 29.62 29.62 24.50 24.50 29.62 26.10 26.62 26.10 26.62 26.62 26.10 26.62 30.10 30.21 30.10 30.21 26.62 26.62 26.62 30.21 30.21 23.66 27.00 23.66 27.00 23.66 27.00 23.66 27.00 23.66 W mm 524 400 508 508 524 508 203 508 622 622 622 767 767 753 753 753 753 622 622 753 663 676 663 676 676 663 676 765 767 765 767 676 676 676 767 767 601 686 601 686 601 686 601 686 601 in. 24.00 19.63 23.88 23.88 24.00 23.88 9.75 23.88 26.25 26.25 26.25 33.61 33.61 33.02 33.02 33.02 33.02 26.25 26.25 33.02 29.51 30.02 29.51 30.02 30.02 29.51 30.02 33.50 33.61 33.50 33.61 30.02 30.02 30.02 33.61 33.61 24.46 27.80 24.46 27.80 24.46 27.80 24.46 27.80 24.46 W/H mm 610 499 607 607 610 607 248 607 667 667 667 854 854 839 839 839 839 667 667 839 750 763 750 763 763 750 763 851 854 851 854 763 763 763 854 854 621 706 621 706 621 706 621 706 621 in. 10.63 9.75 11.75 11.75 10.63 11.75 4.75 11.75 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 8.88 8.88 8.88 8.88 8.88 8.88 8.88 8.88 8.88 D mm 270 248 298 298 270 298 121 298 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 226 226 226 226 226 226 226 226 226
Cat. No.
W/H W D
NEMA 1
W/H W D
DTU200 A NEMA 3R
DTU224NRB a 82254 a 82254NW a 82344 a 82344RB a 82354 92251 82344DS DTU324N DTU324NRB H82344 H82444 a H82454 82454 82444 82454R a 82444R H82254 H82354 82444DS a 82255 a 82255R 82345a 82345DSa 82345Ra 82355 a 82355R a 82445 82445R 82455 a 82455R H82255 H82345 H82355 H82445 H82455 DTU326 DTU426 DTU366 DTU466 DTU326R DTU426R DTU366R DTU466R DTU366AWK a 250 V dc rated.
3
SAFETY SWITCHES
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions: 30100 A (Series F). . . . . . . . . . . . . . . . . . . . . . . . . .
page 3-17 page 3-18 page 3-19 page 3-20 page 3-21
3-22
Dimensions
Class 3110
Put over 100 years of Schneider Electrics experience as a global specialist in energy management to work on your photovoltaic (PV) project. The Square D 1000 Vdc disconnect switch is the perfect solution for your 1000 Vdc PV disconnect applications. It is compact and available in both a 100 and 200 amp non-fusible versions. IEC 60947-1 and 3 certified (file 136861). Extended Life Expectancy Exceeds IEC 60947-3 mechanical endurance requirements by factor of 18 Exceeds IEC 60947-1 electrical endurance requirements by factor of 10 Exceeds NEMA KS-1 mechanical endurance requirements by factor of 3. Easy to Install Preconfigured solar solution Familiar enclosed safety switch design Suitable for both grounded and ungrounded PV Table 3.1: 1000 Vdc Photovoltaic Heavy Duty Disconnect Switch Pricing and Accessories
Factory Installed Accessories System Amp 3 Pole Groundedf
Three-Pole (Grounded System)
Operating range of -37C to 50C Specially designed PV paint reduces solar gain by 40% over standard grey enclosures
Electrical Interlock Electrical Interlock Viewing Windows Terminal Blocks Single Contacta Two Contactsb (Copper)c No. Suffix $ Price No. Suffix $ Price Adder Adder No. Suffix $ Price Adder No. Suffix $ Price Adder
Cat. No.
$ Price
Line
Connector
100
REHU393IP
1672.00
EI1
452.00
EI2
496.00
VW
150.00
TBC
409.00
SA
322.00
GL
263.00
Connector Load
PE
Protective earth terminal
200
REHU394IP
2246.00
EI1
452.00
EI2
496.00
VW
175.00
TBC
409.00
SA
322.00
GL
263.00
4 Pole Ungrounded
Four-Pole (Ungrounded System)
100
Load Line Load Line
REHU493IP
2507.00
EI1
452.00
EI2
496.00
VW
150.00
SA
322.00
GL
263.00
Connector
PE
Protective earth terminal
200
REHU494IP
3965.00
EI1
452.00
EI2
496.00
VW
175.00
SA
322.00
GL
263.00
Order EIK1PV for single contact field-installed kit $311.00. Order EIK2PV for double contact field-installed kit $355.00. Accommodates (2) 250 max Cu or (1) 1/0 max Cu wiring; Order SN20CPV for field-installed kit $246.00. Required when adding surge arrestors. Accommodates (2) 6-300 Cu/Al wiring; One lug for the line connection and one for the surge arrestor connection. Order AL20DTF for field installable kit $159.00. e Order REHGND KIT for field installable kit $100.00. Note: For internal 600 Vdc PV combiner box switches please see our offering of 9422 switches 600 Vdc UL98 listed in digest pages 8-16 and 8-17. Note: For our 600 Vdc PV switch offering please see digest pages 3-43-6. f Terminal blocks standard with 3 pole switches; accommodates (2) 1/0 max Al/Cu or (2) 6 max Al/Cu wiring.
DE1
3-23
a b c d
SAFETY SWITCHES
www.schneider-electric.us
3-24
SAFETY SWITCHES
Table of Contents
Section 4
Power Monitoring and Control
PowerLogic Energy and Power Management Systems
Introduction Power Monitoring Software PowerLogic ION Enterprise Software PowerLogic System Manager Software PowerLogic Scada PowerLogic Powerview Software PowerLogic ION EEM Enterprise Energy Management Software PowerLogic Metering PowerLogic Power and Energy Meters ION8600 ION7550/7650 ION7350/7330/7300 ION6200 PowerLogic ION and Power and Energy Meter Selection Series 700 Power Meter Series 800 Power Meter Series 3000 Circuit Monitor Series 4000 Circuit Monitor Submetering Tenant Metering Software PowerLogic E5600 Socket Meter High Density Meter Enclosures (HDM) Multi Circuit Energy Meters Energy Meter Enercept Meter Split Core Current Transformers Branch Circuit Power Meter Branch Current Monitor Multi-Circuit Meter Submeter Display PowerLogic Solutions for Utilities PrimeRead Software PowerLogic Energy Profiler Online Communications Ethernet Gateways Web Page Generator Engineering Services Consulting & Analysis Industrial Energy Efficiency Power Monitoring Applications Power System Control Applications System Integration Factory Assembled Enclosures Technical Support Power Management University 4-2, 4-3 4-4 4-4 4-5 4-5 4-6
4-7 4-7 4-7 4-8 4-8 4-9 4-10 4-10 4-10 4-11 4-13 4-13 4-14 4-14 4-15 4-15 4-15 4-16 4-16 4-16 4-16 4-17 4-17 4-18 4-19 4-19 4-20 4-20 4-21 4-21 4-21 4-22 4-23 4-23
CM4000
ION7650
New!
4-1
4
POWER MONITORING AND CONTROL
4-2
PowerLogic
Table 4.1:
Data Presentment & Management Enterprise Data Centers; Industrial Buildings, Property Management, Utilities 4-6 4-20 Online Energy Analysis Utilities 4-17 4-20 Data Acquisition, Alarms & Monitoring Supervisory Control & Data Acquisition Power Monitoring System Tenant Submetering
For products see DIGEST section: For services see DIGEST section: Meter Application Automatic Meter Reading Revenue Metering WAGES Utility Pulses Sub-billing Measurement & Verification Cost Allocation & Utility Billing Energy Usage Analysis Reduce Energy Costs & Procurement Optimization Energy Efficiency Allocate Energy Costs Interval Benchmarking & Profiling Total Load Aggregation Energy Efficiency Emissions Tracking Power Factor Correction Peak Demand Reduction Demand Response & Curtailment Improve Maintenance Practices Commissioning & Troubleshooting Equipment Monitoring: transformers, MCCs, switchgear, switchboards, circuit breaker status, protective equipment, capacitors, generators, panelboards, PDU, UPS, etc. Facility Planning Identify Equipment Capacity Determine Transformer Stress Equipment Asset Optimization Improve Efficiency Balance Circuit Loading Balance Generator Usage Optimize Chiller & Mechanical Equipment System Monitoring & Analysis Transient Voltage Detection Sag/Swell Disturbance Monitoring Power Quality & Harmonic Analysis Power Quality Compliance Alarm & System Diagnositics Electrical Distribution Alarm & Event Analysis Waveform capture viewing Remote alarm notification Energy Services Total Energy Control Services Peak Shaving/Generator Control Load Management/Shedding WAGES Advanced Reliability Services Auto Throw Over (ATO) Engineering Services Emergency Power Supply System Test Reporting Sequence of Events Recording (1ms time/stamp) GPS Time Stamping Power System Control Network Protection Consulting Services System Studies (SC/TCC/Arc Flash) Power System Assessments
Water/Wastewater, Industrial, large Commercial Heavy Process commercial buildings, Government Buildings, Buildings, Industry, Data Centers, Military Bases, Military Bases Critical Power Healthcare 4-5 4-4 thru 4-12 4-13 thru 4-16 4-21 4-21 4-22
4-3
PowerLogic
4
POWER MONITORING AND CONTROL
Table 4.3:
Core Software Products System Mgr. Device Limited (1 web-enabled client, 16 devices, up to 32 devices with SMSDL32U, Interactive Graphics) System Mgr. Standard Ed. (1 web-enabled client, MSDE or SQL Personal Edition with Interactive Graphics) System Mgr. Professional Edition (10 web-enabled clients, SQL Server, Advanced Reports, Interactive Graphics) Add On Modules SMS OPC Server Application SQL Server 2005 End User License Active Pager Module - Paging applications with conditional alarms assigned by shift WAGES Module - Monitoring electrical and piped utilities available with engineered project SER Module - Sequence of Events software interface for GPS time synch available with engineered project EPSS Test Report Module available with engineered project Extension Products Enables Standalones (DL & SE) with Remote Web clients (5 pk licenses) Extends SMSDL to 32 device limit Converts SMSDL to SMSSE SMSWebXTR SMSDL32U SMSDL2SE 2575.00 2575.00 8755.00 SMSOPC 2980.00 SMSLIC 1785.00 9789PAGE 3820.00 Available as Engineered Project 9789SER 15000.00 9789EPSSTSTRPT 4650.00
4-4
PM1
PL1
Discount Schedule
PowerLogic
Powerview Software
PowerLogic SCADA
PowerLogic SCADA software was created to meet the requirement for real-time monitoring and control of electrical distribution systems, including fast response times and high reliability through redundancy. PowerLogic SCADA is powered by Citect SCADA technology but is specifically designed for electrical power systems applications. The complete PowerLogic supervisory control and data acquisition (SCADA) solution includes a dynamic graphical user interface, enhanced alarm management, one second response times for control operation and status, transparent redundancy, and reliable communications (through hardware components and network topology). The system also features Sequence of Events Recorder (SER) logs with time stamps of 1ms resolution. PowerLogic SCADA software includes a web-based client for remote viewing capability. The graphical user interface consists of animated objects which change according to status information. The flexible graphics editor includes both ANSI and IEC electrical symbols to facilitate easy one-line diagram creation. Real-time and historical trending is also supported.
PL1
Discount Schedule
4-5
PowerLogic
Personalized dashboards help management and operations personnel monitor all aspects of energy use and respond to opportunities or threats.
PowerLogic ION EEM automatically acquires data from power monitoring and control systems, building and process automation systems, utility information systems, weather services, spot-market energy pricing feeds, and enterprise business applications, cleanses and warehouses it. Personalized, browser-based dashboards and innovative visualization and modeling tools then make the information available to whomever needs it, so you can accurately monitor, validate, predict and control energy-related expenses. From operational cost reductions to procurement support through cost allocation, benchmarking and budgeting, key performance indicators and advanced analytics, PowerLogic ION EEM helps you manage energy in financial terms. It also helps you gain unique insight into the impacts of power quality on your business and all energy assets. From the service entrance to the boardroom, PowerLogic ION EEM software allows energy to be managed as a variable cost.
Key features
Produce aggregate billing, load profile, cost allocation, power quality, forecasting or budget reports to help inform stakeholders and track results against goals.
True enterprise-level software architecture: data quality assurance, data warehouse, web framework Web portal: personalized dashboards, key performance indicators, charts, trends, real-time conditions Reporting: rich and customized content, support for complex data and graphics, scheduled distribution Trending: advanced visualization, dimensional analysis, prediction, statistical rollups Modeling: regression analysis, normalization, correlation, integration of all relevant drivers and contextual data Billing: built-in rate engine and rate wizard Power quality analysis: wide-area event monitoring, classification, filtering, correlation Alarms and events: triggering on complex conditions, notification, logging Integration: meters and other devices, weather and pricing feeds, other enterprise applications (e.g. BAC, ERP) CO2 Report
Typical applications
Manage all utilities (electricity, gas, water, etc.) and emissions through a single, unified interface Benchmark facility performance across an entire enterprise to identify energy inefficiencies Measure and verify savings from energy conservation projects or performance contracts Reduce operational costs, improve processes, and prolong asset life Meet corporate environmental stewardship goals or mandated impact targets Manage demand control schemes, load shedding, peak shaving, base loading or on-site generation Enable participation in real-time pricing and load curtailment programs Optimize procurement by forecasting and budgeting for energy needs and comparing utility rates Identify utility billing errors and validate contract compliance Allocate and recover utilities costs from tenants, departments, processes, etc. Maximize the use of existing infrastructure capacity and avoid overbuilding Identify and reduce risks to uptime
Use advanced billing functions to support energy procurement and manage load or generation assets in response to curtailment or pricing signals.
Monitor power quality risk factors, benchmark performance, determine impacts, validate contract compliance, isolate problem sources, and confirm your return-on-investment.
Data presentment tier Web portal delivers enterprise-wide access through personalized dashboards, reports, detailed analytics, and integration of views from third-party systems. Information and alerts via cell phone, PDA, pager and more. Business applications tier Standard and optional modules tailor functionality to specific needs. Advanced analytics and reporting on every driver and relationship affecting energy cost and reliability. Data management tier Integration of data from many sources: power monitoring and control systems (PowerLogic or third party), utility metering systems (water, air, gas etc.), Internet weather, real-time energy pricing feeds, manual input, energy assets (power distribution and reliability equipment, generators), line-of-business systems (BAC, DCS, ERP, EAM, accounting). Data quality module assures complete and reliable data from all inputs. For price and ordering information, contact your local PowerLogic Sales Specialist or PowerLogic Inside Sales at 1-866-466-7627.
4
POWER MONITORING AND CONTROL
4-6
Table 4.5:
Description Catalog No. ION8600, feature set A, 9S socket base, 5A nominal current inputs, auxiliary power pigtail: 65-120Vac/80-160Vdc, 60 Hz, communications card with: 10baseT Ethernet S8600A0C0H6E0A0A RS-232/485 Optical, RS-485 ION8600, feature set B, 9S socket base, 5A nominal current inputs, auxiliary power pigtail 65-120Vac/80-160Vdc, 60 Hz, communications card with: 10base T Ethernet S8600B0C0H6E0A0A Optical, RS-485 ION8600, feature set C, 9S socket base, 5A nominal current inputs, auxiliary power pigtail 65-120Vdc/80-160Vac, 60 Hz, communications card with: RS-232/485. S8600C0C0H6A0A0A RS-485, Optical port, standard I/O
Table 4.6:
PM1
Discount Schedule
4-7
PowerLogic
PowerLogic ION7350, ION7330 and ION7300 Power and Energy Meter Features
The PowerLogic ION7300 includes: Multiple form factors: transducer integrated and remote display models, GE S1 or ABB FT21 switchboard forms True RMS 3-phase voltage, current, and power that meets stringent ANSI C12.16, Class 10 Power quality: harmonics - individual, even, odd, total to the 15th, maximum 32 samples/cycle Communications: 1 RS-485 port, 1 optional Ethernet port, 1 ANSI Type 2 infrared optical port, 1 PROFIBUS DP port (ION7300 only), onboard web server Supported protocols include : ION, Modbus RTU slave on serial, modem, I/R ports, Modbus TCP through Ethernet Extensive standard I/O includes: 4 analog inputs, 4 analog outputs, 4 digital relay outputs Minimum/maximum recording
-
The ION7330 adds the following features: Time of use - multi-year scheduling, hourly activity profiles 4 digital inputs for status monitoring and pulse counting Communications: a second RS-485 port, internal modem, DNP 3.0 through serial, modem and I/R ports, EtherGate and ModemGate, data/alarms via e-mail and MV-90 on serial and Ethernet ports 12, one second setpoints for single, multi-condition alarms, plus math, logic, trig, log, and linearization formulas Non-volatile onboard memory capacity of 300kb, min/max logging, min/max logging, up to 32 channels of historical logs, timestamp resolution to 0.001 seconds The ION7350 includes the following additional features: Power Quality: sag/swell, individual, even, odd, total harmonics up to 31st , maximum 64 samples/cycle Up to 96 channels of logs and up to 48 cycles of waveform logs Alarm notifications via e-mail
Table 4.7:
The modular PowerLogic ION6200 is a low-cost, ultra-compact meter that offers outstanding versatility and functionality. It is simple to use, and has a big, bright LED display. It offers four-quadrant power, demand, energy, power factor and frequency measurements, and is available in a variety of flexible configurations. It is available as a low-cost base model to which enhanced functionality can be added over the long term. The PowerLogic ION6200 is ideal for customers who need revenue-accurate and/or certified measurements and want easy integration with power distribution assemblies and building automation systems. A Megawatt version is available for applications requiring readings in megawatts and kilovolts. It is well suited for sub-metering, energy cost tracking load profiling, and substation panel metering and is an ideal replacement for analog meters. It can be used for stand-alone metering in custom panels, switchboards, switchgear, gensets, motor control centers and UPS systems. The meter consists of a base unit with options card and a power supply pack, with a remote display being optional.
The standard ION6200 is available with the following parameters: Voltage L-N average and per phase, Voltage L-L average and per phase, Current average and per phase Option EP#1, includes the standard measurements and provides the following additional parameters: I4, kW/mW total, kWh/mWh total, kW/mW peak, Current demand average and per phase, Current peak demand average and per phase, Power factor total Optional Enhanced Package, includes the standard measurements and provides the following additional parameters: kW/mW per phase, kVAR/mVAR total and per phase, kVA/mVA total and per phase, kWh/mWh and del/rec per phase, kVARh/mVARh total and del/rec per phase, kVAh/mVAh total and per phase, kW/mW demand, kVAR/mVAR demand and peak, kVA/mVA demand and peak, Power Factor per phase, Voltage THD per phase, Current THD per phase
4
POWER MONITORING AND CONTROL
Table 4.8:
Description Catalog No. Integrated display, 10A inputs, standard 100-240 Vac power supply, RS485 port (Modbus RTU), Enhanced Package #2 S6200A0A0B0A0A0R TRAN Model, with remote display, 10A inputs, standard 100-240 Vac power supply, RS485 port (Modbus RTU), Enhanced S6200R1A0B0A0A0R Package #2 TRAN Model, (no display), 10A inputs, standard 100-240 Vac power supply, RS485 port (Modbus RTU), Enhanced Package #2 S6200T1A0B0A0A0R Note: Please refer to powerlogic.com for the most complete and up-to-date list of feature availability. Some features are optional.
4-8
PM1
Discount Schedule
PowerLogic
Table 4.9:
Inputs, outputs and control power 3-phase / single-phase Digital in and out / analog in and out Power supply options Power and energy measurements V, I, F, PF Power, demand Energy / time-of-use (energy per shift) ANSI energy accuracy class (% of reading) Measurement Canada Approval Loss compensation Power quality analysis Compliance monitoring (e.g. EN50160) Flicker measurement Transient disturbance capture Sag and swell monitoring Harmonics measurement Uptime (number of 9's) calculation Waveform capture Data and event logging Trend / snapshot Min/max Events Timestamp resolution (seconds) GPS sync Setpoints, alarms and control Annunciation / call out on alarm Trigger logging Trigger relay or digital output control / / / / / / 0.001 / 0.001 / 0.001 / 0.001 0.001 0.001 63 rd / 0.2 / 0.2 / 0.5 / 0.5 / 0.5 / 0.5 / 16,4 / 4,4 AC/DC / 16,4 / 4,4 AC/DC / 4,4 / 4,4 AC/DC / 4,4 / 4,4 AC/DC / 4,4 / 4,4 AC/DC / 0,2 / AC/DC
63 rd
31st
63 rd
31st
15th
15th
THD
Special features Custom programming: arithmetic, boolean, object-oriented Downloadable firmware Communications Ethernet port / web / email // // // // // // // // / / Telephone modem port Infrared port RS485 / RS232 ports / / / / / / / / / Modbus / DNP / MV-90 protocols // // // // // // // / / / / b Specifications represent maximum capabilities with all options installed. Some options are not available concurrently. This is not a complete feature list, please refer to detailed product specifications.
PL1
Discount Schedule
4-9
PowerLogic
PowerLogic Series 700 Power Meter
Metering
The PowerLogic PM700 series power meters offer all of the measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit extending only 50 mm behind the mounting surface (less than 2 inches). With its large display, you can monitor all three phases and neutral at the same time. The anti-glare display features large 11 mm high characters and powerful backlighting for easy reading, even in extreme lighting conditions and viewing angles.
Series 700 Power Meter
Power and current demand, THD and min/max reading in basic version A high-performance solution for trouble-free monitoring of your electrical installation. Energy Class 1 as defined by IEC 62053 (or IEC 61036) Suitable for sub-billing and cost-allocation applications. Table 4.10:
Description Series 700 Power Meters PM710 Power Meter with integrated display and comms PM750 Power Meter with (2) digital input, (1) digital output PM710 PM750 710.00 950.00 Catalog No. $ Price
Monitor current, voltage, power and energy simultaneously Trending/Forecasting Curves functionality (PM850/870) 128 samples/cycle-zero blind metering Waveform capture (PM850), configurable waveform capture (PM870) Onboard logging (80k in PM820, 800k in PM850/PM870) Detection of sub-cycle sags/swells on both voltage and current Individual harmonics up to 63rd on both current and voltage
Available with 2 standard Digital I/O Field installable Digital and Analog I/O THD measurement Meets IEC 60687, IEC 62053 and ANSI C12.20 Class 0.5S accuracy Programmable (logic and mathematical functions) Optional field installable Ethernet communications card with standard and custom web pages GPS Time Synchronization (PM870)
Table 4.11:
Description Series 800 Power Meters PM820 Power Meter with integrated display, THD, Alarming, 80kb Logging PM850 Power Meter with integrated display, THD, Alarming, 800kb Logging, Waveform Capture PM870 Power Meter with integrated display, THD, Alarming, 800 kb Logging, configurable Waveform Capture, Sag/Swell Detection PM820 Meter unit only without display PM850 Meter unit only without display PM870 Meter unit only without display Series 800 Power Meter Accessories PM800 Display for integrated meter unit PM800 Module, 2 digital outputs, 2 digital inputs PM800 Module, 2 digital outputs (relays), 6 digital inputs PM800 Module, 2 digital out, 2 digital in, 2 analog out, 2 analog in PM800 Mounting adapter for CM2000 PM8ECC Ethernet Communications Card; 10/100 Base T Ethernet port and 1 RS-485 master port Catalog No. PM820 PM850 PM870 PM820U PM850U PM870U PM8D PM8M22 PM8M26 PM8M2222 PM8MA PM8ECC $ Price 2390.00 3889.00 4799.00 2050.00 3529.00 4460.00 443.00 635.00 635.00 856.00 267.00 1150.00
4
POWER MONITORING AND CONTROL Series 3000 Power Meter
Comes with 8Mb of standard memory allowing for more data logging than any other meter in its class 128 samples/cycle allow for zero blind metering Sag/Swell disturbance monitoring(CM3350) 100 ms Event recording(CM3350) Harmonic Powerflows to the 40th harmonic Sequence of events recording using GPS synchronization
Built-in Trending and Forecasting functionality allows you to forecast energy usage up to 4 days in advance Custom web pages with optional Ethernet Communications Card Field installable Digital I/O card Meets IEC 60687 and ANSI C12.20 Class 0.5S accuracy
Table 4.12:
Description Series 3000 Circuit Monitors Instrumentation, On-board Data Logging Waveform Capture, Disturbance Waveform Capture, Configurable I/O, 0.15% Accuracy Same as CM3250 plus Sag/Swell Disturbance Detection and 100 ms RMS Event Recording CM3250 CM3350 3944.00 5121.00 Catalog No. $ Price
4-10
PL1
Discount Schedule
PowerLogic
PowerLogic Series 4000 Circuit Monitor
Metering
The award winning, Web-enabled PowerLogic Series 4000 Circuit Monitor (CM4250) is the most advanced permanently mounted circuit monitor in the industry today. Designed for critical power and large energy users who cannot afford to be shut down, the CM4250 provides the ability to monitor, troubleshoot and preempt power quality problems. Transients (disturbances lasting less than one cycle) are particularly difficult to detect, due to their short duration. The CM4000T detects and captures oscillatory and impulsive transients (up to 10,000V peak, line-to-line at 5 MHz per channel) as short as one microsecond in duration. The CM4000T automatically performs a high-speed transient waveform capture and a longer disturbance capture to show the conditions surrounding an event. The CM4000T maintains a complete historical record of the number of transients per phase, along with the magnitude, duration and time of occurrence of each. It also performs a stress calculation to determine the circuits that have received the greatest stress from transient overvoltages.
CM4000T with VFD Display
PCM4000
Waveform capture with up to 512 samples/cycle Built-in Trending and Forecasting functionality allows you to forecast energy usage up to 4 days in advance Sag/Swell disturbance monitoring Two option card slots for field installable cards Optional field installable Ethernet communications card with standard and custom web pages Alarm Setpoint Learning feature allowing optimum threshold setting (patent pending) Multiple alarms including standard, digital, Boolean, high-speed, and disturbance alarms Waveshape alarm monitoring High speed transient voltage detection at 5 MHz per channel with field installable CVMT current/voltage module True RMS Metering through the 255th harmonic Also available in a rugged sealed case as a Portable Circuit Monitor
Extended waveform capture (up to 110 seconds) Field installable Digital/Analog I/O cards and flexible I/O extender modules Harmonic powerflows up to the 40th harmonic Standard KYZ pulse output Standard 32 MB of non-volatile memory Integrated power quality standards including EN50160, IEC 61000-4-15 (Flicker) Sequence of events recording using GPS synchronization technology Oscillatory transient detection and recording Extended range current/voltage module(CVMXR) for higher inrush currents available, field installable UL Listed, CSA Approved, CE Marking, NOM Approved, FCC compliant
Table 4.13:
Series 4000 Circuit Monitors Instrumentation, On-board Data Logging, Waveform Capture, Disturbance Recording, Configurable I/O, 0.04% Accuracy Same as CM4000 plus Impulsive Transient Detection and Flicker (IEC 61000-4-15) Portable CM4000 Base Unit, Detachable Vacuum Fluorescent Display, Ride-though Module, Cable Set and Carrying Bag Portable CM4000 plus Impulsive Transient Detection and Flicker (IEC 61000-4-15) Series 4000 Circuit Monitor Accessories Field installable I/O card with 3 relay outputs, 1 pulse output (KYZ) and 4 status inputs I/O Extender module with 4 DC status inputs, 2 DC digital outputs, 1 analog input and 1 analog output I/O Extender module with 4 status inputs and 4 analog inputs (4-20 mA) I/O Extender module with 8 status inputs I/O Extender module with no pre-installed I/O a Ethernet Communications Card; 100 MB Fiber or 10/100 MB UTP Ethernet port and 1 RS-485 master port Current/Voltage module Current/Voltage module with high speed transient detectionb 4-line x 20 - character liquid crystal display with backlighting 4-line x 20 - character vacuum fluorescent display with proximity sensor I/R communications interface for the vacuum fluorescent display 4 foot display cable 12 foot display cable 30 foot display cable Portable Circuit Monitor 5A CT 150/300/600A Range (Order 3 for complete set) Portable Circuit Monitor 5A CT 500/1000/1500A Range (Order 3 for complete set) Portable Circuit Monitor 5A CT 1000/2000/3000A Range (Order 3 for complete set) a Contact your nearest Square D/Schneider Electric sales office for additional I/O options. b CM4000 is field upgradeable to provide additional features of specified module. c Also available for CM3000
ECC21
Table 4.14:
Description PowerLogic Satellite Time System, Circuit Monitor and SEPAM GPS Time Synchronization, 100 microsecond accuracy Satellite Time Reference Module Smart Antenna Module Smart Antenna Module Interface Cable - 200 FT Power Supply, 24DC/50W, DIN-mountable
PL1
Discount Schedule
4-11
PowerLogic
Submetering
Table 4.15:
Inputs, outputs and control power 3-phase / single-phase Digital in and out / analog in and out Power supply options Power and energy measurements V, I, F, PF Power, demand Energy / energy per shift (time-of-use) Energy accuracy (%) Standards compliance to ANSI / IEC Power quality analysis Compliance monitoring (e.g. EN50160) Flicker measurement High-speed transient disturbance capture (200 ns) Transient disturbance capture Disturbance direction detection Sag/swell monitoring Harmonics measurement Uptime (number of 9's) calculation Waveform capture Waveshape alarm Data and event logging Trend / billing Minimum and maximum Events / maintenance Timestamp resolution (seconds) GPS sync Setpoints, alarms and control Annunciation / call out on alarm Trigger logging Trigger relay or digital ouput control Special features Custom programming: arithmetic, boolean Downloadable firmware Communications Ethernet port / web / email RS485 / RS232 ports Modbus protocol
4
POWER MONITORING AND CONTROL
4-12
PL1
Discount Schedule
PowerLogic
PowerLogic Submetering
Submetering
In today's increasingly competitive commercial property market, attracting and retaining high-quality, long-term tenants by offering exceptional value is the primary goal. Balancing these premium services and reliable infrastructure vs. the financial exposure to volatile utility costs is the challenge. Minimizing energy costs requires information on how energy usage translates into money spent. PowerLogic energy sub-metering systems are specifically engineered to address the measurement, verification and billing needs of multi-tenant properties.
Residential high-rise and low-rise Campuses Shopping centers Malls / food courts Offices Commercial buildings
PowerLogic energy management and metering systems are ideal for multi-tenant buildings providing:
Metering & Verification tools to assure compliance to Energy Policy Act 2005 Integrated approach from simple energy allocation requirements to high-end power quality Monitor energy usage and efficiency to accurately recover the costs while providing tenants with energy and a reliable infrastructure Implement energy efficiency initiatives essential to obtaining LEED certification
Real, reactive, and apparent energy values. Onboard interval data logging (load profiles). Revenue grade accuracy ANSI C12.20 0.2% / 0.5%. Automatic configuration of service type and voltage. Onboard diagnostics continually monitors for equipment failures, improper installation wiring, poor load conditions, poor power quality conditions and tampering. S-base meter socket compatible.
Contact your local Schneider Electric sales office for pricing and availability.
PL1
Discount Schedule
4-13
PowerLogic
PowerLogic High Density Metering
Submetering
www.powerlogic.com
FOR CURRENT INFORMATION
High Density Metering (HDM) is engineered to answer the metering and billing needs of multi-tenant properties:
HDM comes standard with the PowerLogic PM210, PM750 or ION6200 meters. Please consult the factory to discuss cabinets equipped with the PowerLogic PM800 series meters. Lockable, 16 gauge NEMA Type 1 enclosure provides tamper-resistant security. NEMA Type 3R also availalbe. Please consult factory. Mounting channel and surface-mount flanges simplify installation. Factory installed cover plates are included to cover empty meter spaces. Factory installed wiring harness simplifies installation of additional meters and provides future system expansion. Each High Density Metering cabinet is provided with standard RS485 Modbus, and optional Modbus Ethernet TCP communications are availalbe. For wireless communications, please consult factory. Available in the following configurations: 208Y/120V wye; 240V delta, 48 = 480Y/277V wye (PM210/PM750), and with provided 2.5:1 CPT (control power transformer); 480Y/277V wye (6200); 480V delta (6200, PM210 or PM750). CTs required. Must select separately.
Table 4.17:
Category
Meter Series
HDM
HDM HDM a b c
PM210 PM750
1 or 3 3
1, 4, 8, or 1-16b 16 1, 4, 8 or 16 1-16b
1 1
Voltage Ordering Notes: 12 = 208Y/120V wye; 240V delta. 48 = 480Y/277 wye; (PM210/PM750) 4T = with provided 2.5:1 CPT (control power transformer); 480Y/277 wye (6200); 480V delta (6200, PM210 or PM750) Meters Ordering Notes: Please indicate the number of meters to be pre-installed when placing your order. You may order any number of meters in the enclosure between one and the maximum number of meters each cabinet will hold. Please enter R as the last digit for Type 3R outdoor on 1 or 4 HDM enclosure with the 6200 series meter.
8 meter configuration
Enclosure Power Meters, installed Installation bulletin for Enclosure Wall hanging bracket Installation bulletin for Meters
Table 4.18:
Description Auxiliary Wiring Harness for installation of additional meters (includes connectors and shorting terminal blocks) Cover plate for empty meter base Water and Gas Meters 50 Amp HDM Solid Core Current Transformer, 1.13 window size 100 Amp HDM Solid Core Current Transformer, 1.13 window size 125 Amp HDM Solid Core Current Transformer, 1.13 window size 150 Amp HDM Solid Core Current Transformer, 1.13 window size 200 Amp HDM Solid Core Current Transformer, 1.13 window size 250 Amp HDM Solid Core Current Transformer, 1.13 window size 400 Amp HDM Solid Core Current Transformer, 1.13 window size
HDMCVRPLT 5.90 Consult factory for details HDMCT050S1 35.00 HDMCT100S1 35.00 HDMCT125S1 35.00 HDMCT150S1 35.00 HDMCT200S1 52.00 HDMCT250S1 52.00 HDMCT400S1 52.00
The PowerLogic E4000 series multi-circuit energy meters combine accurate electricity submetering with advanced communications technology. They are ideal for multi-tenant or departmental metering applications within office towers, condominiums, apartment buildings, shopping centers and other multi-point environments, metering up to 24 individual circuits from the same meter. The E4800 series has a system accuracy of 0.5% for power and energy, including the metering class CTs. Each meter is available separately or as part of a Scquare D integrated power center (IPC) for use in building retrofits or new construction. Table 4.19:
Description Energy measurement for 24 (1CT) or 12 (2CT) single-phase circuits or 8 (3CT) 3-phase circuits; Ethernet; modem; onboard interval logging; compatible with 80mA low-power CTs (solid-core) Energy measurement for 24 (1CT) or 12 (2CT) single-phase circuits or 8 (3CT) 3-phase circuits; Ethernet; modem; onboard interval logging; compatible with 333mV low-power CTs (solid-core or split-core) Energy measurement for 24 (1CT) or 12 (2CT) single-phase circuits or 8 (3CT) 3-phase circuits; Ethernet; modem; onboard interval logging; compatible with standard 5A CTs (solid-core or split-core) 200A current transformer (CT), 80mA secondary, solid-core (1 CT) 400A current transformer (CT), 80mA secondary, solid-core (1 CT) 800A current transformer (CT), 80mA secondary, solid-core (1 CT) Catalog No. E488010SQD E483310SQD E480510SQD ECT80200 ECT80400 ECT80800 $ Price Consult Factory for Pricing Consult Factory for Pricing Consult Factory for Pricing Consult Factory for Pricing Consult Factory for Pricing Consult Factory for Pricing
4
4-14
2009 Schneider Electric All Rights Reserved
PL1
Discount Schedule
PowerLogic
Submetering
Energy Meter
Energy Meter
Table 4.20:
Catalog No. EMB1010 EMB1021 EMB1032 EMB2010 EMB2021 EMB2032 EMB2043 EMB2083 EMB3010 EMB3021 EMB3032 EMB3043 EMB3083 EMB3084 EMB3164
Table 4.22:
Catalog No. EME1010 EME1021 EME1032 EME2010 EME2021 EME2032 EME2043 EME2083 EME3010 EME3021 EME3032 EME3043 EME3083 EME3084 EME3164
Table 4.21:
Additional CT Sets
Table 4.23:
Catalog No. Description $ Price EMCT010 100 A, .518 x 1.28 ID, 1 CT 92.00 EMCT021 200 A, 0.75 x 1.10 ID, 1 CT 99.00 EMCT032 300 A, .90 x 1.90 ID, 1 CT 106.00 EMCT043 400 A, 2.45 x 2.89 ID, 1 CT 106.00 EMCT083 800 A, 2.45 x 2.89 ID, 1 CT 123.00 EMCT084 800 A, 2.45 x 5.50 ID, 1 CT 130.00 EMCT164 1600 A, 2.45 x 5.50 ID, 1 CT 130.00 Note: CT quantity and amperage must match meter model. Total of combined loads must not exceed rating of meter. All additional CTs shipped with 6 ft. white and black color-coded wire leads.
Catalog No. Description $ Price EMCB Energy Meter Communication Boarda 267.00 EMFP1 Energy Meter Fuse Pack, Set of 1 47.00 EMFP2 Energy Meter Fuse Pack, Set of 2 94.00 EMFP3 Energy Meter Fuse Pack, Set of 3 142.00 EMBOND Energy Meter Bonding Kit 117.00 a Energy Meter communication board (EMCB) can be used with all models of the Energy Meter. Order one EMCB for each Energy Meter where either kW demand and/or communication is specified.
Enercept Meter
Table 4.25:
Catalog No. ENA485 EDI32 2W485C EMBK-3 PS24
Accessories
Description Enercept Network Adapter Enercept Display Interface 2-Wire 232-485 Conv Enercept Mounting Brackets (Set of 3) 24Vdc Power Supply (for use with EDI or ENA) $ Price 471.00 1338.00 78.00 75.00 157.00
PowerLogic Split Core Current Transformers-Instrument Grade 5 Amp Split-Core Current Transformers
The 3090 SCCT series of split-core current transformers provide secondary amperage proportional to the primary (sensed) current. For use with Circuit Monitors, Power Meters, data loggers, chart recorders and other instruments the 3090 SCCT series provides a cost-effective means to transform electrical service amperages to a 0-5A level compatible with monitoring equipment. Note: Max. Voltage without additional insulation 600Vac. Do Table 4.27: not apply 600V Class current transformers to circuits having a Catalog No. Description $ Price phase-to-phase voltage greater than 600V, unless adequate additional insulation is applied between the primary conductor 3090SCCT022 Split Core CT - 200A (sz.2): 1.25" x 1.51 120.00 3090SCCT032 Split Core CT - 300A (sz.2): 1.25" x 1.51 120.00 and the current transformers. Square D assumes no 3090SCCT043 Split Core CT - 400A (sz.3): 2.45" x 2.89 129.00 responsibility for damage of equipment or personal injury 3090SCCT063 Split Core CT - 600A (sz.3): 2.45" x 2.89 129.00 caused by transformers operated on circuits above their 3090SCCT083 Split Core CT - 800A (sz.3): 2.45" x 2.89 129.00 3090SCCT084 Split Core CT - 800A (sz.4): 2.45" x 5.05 137.00 published ratings.
3090SCCT124 3090SCCT164 Split Core CT - 1200A (sz.4): 2.45" x 5.50 Split Core CT - 1600A (sz.4): 2.45" x 5.50 160.00 165.00
PL1
Discount Schedule
4-15
Catalog No. Description 3020B012b Basic 100A, 1.25" x 1.51" ID 3020B032b Basic 300A, 1.25" x 1.51" ID 3020B043b Basic 400A, 2.45" x 2.89" ID 3020B083b Basic 800A, 2.45" x 2.89" ID 3020B084b Basic 800A, 2.45" x 5.50" ID 3020B164b Basic 1600A, 2.45" x 5.50" ID 3020B244b Basic 2400A, 2.45" x 5.50" ID 3020E012 Enhanced 100A, 1.25" x 1.51" ID 3020E032 Enhanced 300A, 1.25" x 1.51" ID 3020E043 Enhanced 400A, 2.45" x 2.89" ID 3020E083 Enhanced 800A, 2.45" x 2.89" ID 3020E084 Enhanced 800A, 2.45" x 5.50" ID 3020E164 Enhanced 1600A, 2.45" x 5.50" ID 3020E244 Enhanced 2400A, 2.45" x 5.50" ID b See Handout / Instruction Bulletin for derating properties.
Table 4.26:
Basicb
PowerLogic
PowerLogic Branch Circuit Power Meter
Submetering
Class 3030
BCM42
The Branch Circuit Power Meter (BCPM) is ideal for data center customers who are focused on eliminating costly downtime, managing existing capacity efficiently, and reducing energy cost. The BCPM helps data center managers by providing alarms that signify potential issues within the power system and supplying power and energy data down to the circuit level. This data can indicate areas wither over-used or under-used within the facility. It can also be used to effectively control energy cost. The BCPM can monitor up to 84 circuits and fits any Power Distribution Unit (PDU) or Remote Power Panel (RPP) with minimal space requirements. It has a wide monitoring range allowing customers to monitor circuit current from 0.25A to 100A with high accuracy (3% for current 0.25A to 2A and 2% for current 2A to 100A. It can also measure power and energy readings at the circuit level as well as the incoming main. This eliminates the need for two different meters. The BCPM also has a flexible numbering scheme which allows customers to match that of the PDU or RPP and field configuration adds ease to either a new or a retrofit installation.
Key features:
Cost effective communications Easily integrates into a PowerLogic system or other existing networks using Modbus communications
Table 4.28:
Catalog No. BCPMA042D BCPMB042D BCPMC042D BCPMA142D BCPMB142D BCPMC142D BCPMA084D BCPMB084D BCPMC084D BCPMA184D BCPMB184D BCPMC184D Description 42 circuit power and energy meter. Includes 2 CT strips, 21 CTs per strip, 3/4 CT spacing. 42 circuit meter, measures power and energy on the mains, current per circuit. Includes 2 CT strips, 21 CTs per strip, 3/4 CT spacing. 42 circuit current meter. Includes 2 CT strips, 21 CTs per strip, 3/4 CT spacing. 42 circuit power and energy meter. Includes 2 CT strips, 21 CTs per strip, 1 CT spacing. 42 circuit meter, measures power and energy on the mains, current per circuit. Includes 2 CT strips, 21 CTs per strip, 1 CT spacing. 42 circuit current meter. Includes 2 CT strips, 21 CTs per strip, 1 CT spacing. 84 circuit power and energy meter. Includes 4 CT strips, 21 CTs per strip, 3/4 CT spacing. 84 circuit meter, measures power and energy on the mains, current per circuit. Includes 4 CT strips, 21 CTs per strip, 3/4 CT spacing. 84 circuit current meter. Includes 4 CT strips, 21 CTs per strip, 3/4 CT spacing. 84 circuit power and energy meter. Includes 4 CT strips, 21 CTs per strip, 1 CT spacing. 84 circuit meter, measures power and energy on the mains, current per circuit. Includes 4 CT strips, 21 CTs per strip, 1 CT spacing. 84 circuit current meter. Includes 4 CT strips, 21 CTs per strip, 1 CT spacing. $ Price 3569.00 2901.00 2331.00 3569.00 2901.00 2331.00 5748.00 4627.00 3495.00 5748.00 4627.00 3495.00
The Branch Current Monitor reports the current level of each of the breakers of a panelboard to provide timely circuit loading information. In addition, as the circuit load approaches one of two user set levels, an alarm can be generated back to the monitoring software such as PowerLogic System Manager Software. Four models of the Branch Current Monitor are available. The BCM42 consists of rail mounted solid-core CTs intended for mounting inside new panelboards or complete panel retrofits. The BCM42SR is designed to fit into a column width panel design. The BCMSC model is made up of split-core CTs that are an ideal solution for retrofit applications in existing panelboards. The BCMSC_ _ H is a 100 Amp version of the split core design. Table 4.29:
Catalog No. Description BCM42 Branch Circuit Monitor 42 circuits, 3/4 center line CT spacing, 1050 Amp range, configurable BCM42C1 Branch Circuit Monitor 42 circuits, 1 center line CT spacing, 1050 Amp range, configurable BCM42SR Branch Circuit Monitor, single row, 3/4 on center CTs BCM42SRC1 Branch Circuit Monitor, single row 1 on center CTs BCMSC12 Branch Circuit Monitor, split core, 12 CTs BCMSC18 Branch Circuit Monitor, split core, 18 CTs BCMSC24 Branch Circuit Monitor, split core, 24 CTs BCMSC30 Branch Circuit Monitor, split core, 30 CTs BCMSC42 Branch Circuit Monitor, split core, 42 CTs BCMSC12H Branch Circuit Monitor, 100A split core 12 CTs BCMSC24H Branch Circuit Monitor, 100A split core, 24 CTs BCMSC42H Branch Circuit Monitor, 100 split core, 42 CTs Note: CT hole size accommodates up to #6 THHN insulated conductor. $ Price 2350.00 2350.00 2950.00 2950.00 1975.00 1975.00 2350.00 2750.00 3250.00 2225.00 3300.00 4950.00
Designed for OEM style placement in electrical distribution equipment the MCM8364 is configurable to meter 1 or 3 phases of up to eight individual loads, six loads if neutral monitoring is required. The MCM will monitor up to 10,000 amps per service using standard 5 Amp CTs. All of the metered circuits must share a common voltage source. The MCM8364 is a great solution for monitoring critical power distribution equipment and provides 24 different electrical metering quantities plus an additional nine Modbus register alarms. With one RS-485 connection, the multi-circuit meter provides Modbus RTU communications output that communicates to each individual metered circuit. Up to 30 multi-circuit meters can be addressed on the same Modbus network. The multi-circuit meter can provide warnings to the central monitoring computer via its Modbus output using the MNode software provided or can be integrated into PowerLogic SMS software. The MCM also works with the submeter display as shown below. Electrical Data: Energy Consumption (kWHr), Real Power (kW), Reactive Power (kVAR), Apparent Power (kVA), Power Factor Total, Voltage, L-L, avg. of 3 phases, Voltage, L-N, avg. of 3 phases, Current, average of 3 phases, Real Power (kW) phase A, B, & C, Power Factor, phase A, B,&C, Line to Line Voltage, phase A-B, B-C, A-C, Line to Neutral Voltage, phase A-N, B-N, C-N, Current, phase A, B, & C, Frequency (measured from phase A) (Hz). Modbus Alarms: Over Voltage, Under Voltage, Over Current, Under Current, Over kVA, Under kVA, Phase Loss A, Phase Loss B, Phase Loss C Table 4.30:
Catalog No. MCM8364 Description Multi-Circuit Meter 8364 $ Price 1863.00
4
POWER MONITORING AND CONTROL
Submeter Display
4-16
PL1
Discount Schedule
PowerLogic
PowerLogic Solutions for Utilities
Square D PowerLogic delivers complete, cutting-edge web-enabled solutions for many of the utility industry's most demanding metering, billing and information management challenges. For many years, regulated utilities, ESCOs and deregulated energy providers have utilized our proven, scalable meters and software to obtain the accurate, real-time information they need to meet their organization's business goals. Cost-effective PowerLogic systems enable energy providers to:
Maximize competitiveness, increase reliability, streamline operations, and improve service Manage wholesale energy transactions across wide geographical areas Provide value-added services that enhance customer relationships Improve revenue metering, billing accuracy and ensure and report on regulatory compliance Provide key personnel with energy information to make analytical and strategic business decisions, optimize distribution assets, and profit from free market opportunities
PowerLogic's advanced revenue meters are high quality, flexible and scalable devices that offer a combination of capabilities unmatched in the industry. Whether integrated with thirdparty systems or combined with compatible PowerLogic software, Square D can help utilities address:
With the flexibility of ION technology, multiple form factors, extensive I/O, and an unmatched feature set, the PowerLogic ION8600 is a powerful device in substation automation, SCADA, and billing applications.
Transmission grid and revenue metering PowerLogic provides high-accuracy meter information for grid-wide billing applications and offers MV-90 support and integration into SCADA. Substation monitoring A PowerLogic solution provides the tools to protect valuable equipment from faults, disturbances, and overloading. Power quality analysis Waveform recording, transient detection, sag/swell, symmetrical components and many more additional capabilities are available when combined with PowerLogic ION Enterprise software. Service entrance metering The PowerLogic ION8600 billing meter can be used to manage electricity contracts for energy suppliers and consumers, plus web reporting, sub-metering services, load management and much more. Demand response and load curtailment PowerLogic meters and software can also be used as part of a demand response/load curtailment system.
Square D PowerLogic utility solutions resist obsolescence and are engineered to provide fast payback and easy scalability so you can add metering points and communications channels as your organization evolves.
PrimeRead Software
PrimeRead software is a multi-vendor, automated data collection software for utilities that makes data exchange with corporate IT systems for billing, operations and customer information fast and easy. PrimeRead software offers more than just large-scale data acquisition from commercial and industrial (C&I) metering devices though. It provides communications network flexibility, configurable data validation and a true Windows interface.
Multi-port, (serial, optical, internal modem, Ethernet) plus multi-protocol communications (Modbus RTU, Master, Slave, DNP 3.0, Modbus TCP) and a unique gateway capability provide industry leading integration capability
Typical applications
Implement C& I data collection with more flexibility, scalability and reliability Enable meter data management for AMI Perform validation, estimating and editing
For price & ordering information, contact your local PowerLogic Sales Specialist or PowerLogic Inside Sales at 1-866-466-7627.
Analyze data from across your grid and immediately and share it with utility personnel, grid operators, or energy consumers. POWER MONITORING AND CONTROL
2009 Schneider Electric All Rights Reserved
4-17
PowerLogic
Key features:
Applications:
Data access and analysis Automated reporting Estimated bills and rate comparisons Demand response and curtailment programs RTP programs Alarming Administration tool
-
Energy load analysis Energy budgeting and bill forecasting Demand response and load curtailment program management Real-time pricing program management EPO's Real-Time Pricing module lets users see interval data for accounts with future pricing information, and multiply that data against a price stream.
For price & ordering information, contact your local PowerLogic Sales Specialist or PowerLogic Inside Sales at 1-866-466-7627.
4
POWER MONITORING AND CONTROL
4-18
PowerLogic
EGX100 Ethernet Gateway
PowerLogic Ethernet Gateways are available in two models-EGX100 and EGX400 providing direct connection to Ethernet-Modbus/TCP networks to make energy and power monitoring information available over local and wide area networks.
The EGX100 provides low-cost, reliable, Ethernet to serial-line connectivity in a compact, DIN-rail mounted package. Enabled by Power over Ethernet (PoE IEEE 802.3af), the EGX100 simplifies installation by eliminating the need for power supplies plus provides a Web-based interface for configuration and diagnostics. The EGX400 has two serial ports providing Ethernet access to 64 serial devices (more with repeaters) and includes the ability to e-mail historical data plus provide browser-based access to real-time and historical interval data logging/trending information allowing electrical distribution systems to be better managed by utilizing Ethernet and Internet technologies.
Advantages
EGX100 lets the Administrator assign access to setup pages by user groups
Easy to setupNo special software required. Configuration via Microsoft Internet Explorer or Hyperterminal. Easy to troubleshootDetailed diagnostics for communication ports through a Web interface. Easy to maintainField upgradable firmware lets you add new features while reducing costly downtime. Secure-Customizable, password-protected access to configuration. Cost-effective, high-speed communicationsUse existing LAN infrastructure to reduce communications wiring and network management costs. Open platform provides broad connectivityModbus TCP/IP over Ethernet allows transparent access via intranet/internet. Each gateway supports up to 32 Modbus or PowerLogic protocol devices. Subnet initiated communicationsThe gateway supports a slave mode for connecting a serial-line based system to Ethernet. For example, a building management system with a Modbus serial interface can route to 16 remote Modbus TCP/IP interfaces supporting up to 128 serial-line devices. Extended temperature range -25 to 70C enables operation in harsh environments.
Table 4.32:
Built in tabs provide easy DIN rail mounting solution.
Control Power 24Vdc control power (from external source) Power Over Ethernet Protocols Ethernet: HTTP FTP, Modbus TCP/IP, SMTP, SNMP (MIB2), SNTP TCP, UDP ICMP, ARP , , , Serial: Modbus RTU, Modbus ASCII (EGX100 only), JBUS, PowerLogic (SY/MAX) Ports Serial: RS485 Serial: RS232/485 configurable Ethernet UTP (10/100) Fiber (100Mb) Integral web server Web page generation tool Maintenance/diagnostics Gateway administration setup Comprehensive meter reading Interval logging/trends User defined custom pages Historical Data Logging Interval data File transfer on scheduled basis Export to Excel via web query Manual FTP EGX100 Type 950.00 x x x x EGX400 2460.00 x $ Price
x x 1 1 1 1 x x x x 32 devices x x email x x
1 1
x x
EGX400 Ethernet Gateway offers you a window into your power equipment
The PowerLogic WebPageGenerator (WPG) creates and downloads application specific web pages to PowerLogic Ethernet gateways (EGX400, ECC21, PM8ECC) with minimal user intervention. The user simply identifies the serial devices connected to the Ethernet gateway in this wizard-based software utility. The utility takes care of the rest. This utility is available for download from www.powerlogic.com.
PL1
Discount Schedule
4-19
PowerLogic WebPageGenerator
Engineering Services
The Square D Power System Engineering team offers a wide range of engineering services to improve the safety, efficiency and reliability of your power distribution system. The team is comprised of registered professional engineers, safety trained and equipped, to perform a variety of engineering functions.
Short-circuit analysis Time-current coordination Motor starting/voltage drop Motor starting/torque-speed Safe motor re-energization
Harmonic analysis Transient analysis Power factor correction analysis Other system specific analysis
Arc Flash Analysis Square D offers on-site services to perform arc flash analysis for a facility, complex, office, or campus. An Arc flash analysis is used to determine
Appropriate Personal Protective Equipment (PPE) Low cost arc flash reduction methods
Power Quality Studies Square D offers onsite power quality engineering studies and solutions to eliminate process disruptions, power system shutdowns, and equipment damage due to electrical power system disturbances. A power quality study is used to...
Determine compliance with the IEEE 519-Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems guidelines Identify most cost-effective solution to power quality problems Solve process disruptions due to power disturbances Reduce economic effects of poor power quality Identify disturbances originating on electric utility system and improvements to reduce the number and severity
Basic codes and standards compliance Protective coordination assessment Maintenance program review Recommendations for power system optimization Power quality troubleshooting and analysis Power factor and harmonics analysis
Electrical safety hazards Short-circuit withstand overview Single-line documentation of power system Power monitoring recommendations Loading measurements
New equipment installation Existing equipment modification Ground Fault Schemes for multiple source distribution systems High Resistance Grounding (HRG) Conversion Automatic Transfer Control Schemes & Generator Operations
4
POWER MONITORING AND CONTROL
Square D professional engineers - safety trained and equipped - will listen to your concerns and goals, define the problem or enhancement, and engineer the solution that best satisfies your needs. For additional information on power system engineering services and pricing, contact your nearest Square D/Schneider Electric office.
Total Energy Control Comprehensive integration of all three areas affecting energy efficiency Procurement (electricity and gas) Demand management Optimization of process and plant utilities Program deliverables: Long-term Energy Action Plan Energy efficiency projects Ongoing accountability for results
2009 Schneider Electric All Rights Reserved
4-20
PowerLogic
Engineered Solutions
Engineering Services
Schneider Electric provides an engineered solution approach to your specific power system applications. Our total solutions for power monitoring and power system controls allow greater safety, reliability, and energy efficiency of your power systems. As a long standing industry leader in Power Monitoring and Control Systems, we understand your power system requirements and needs. All of our Engineered Solutions are tailored to your specific system requirements. Schneider Electric is your total Solution provider.
EPSS Emergency Power Supply Systems The PowerLogic EPSS Test Report provides information regarding the health and status of the emergency power supply system, including automatic transfer switches and generators. SER Sequence of Events Recording The PowerLogic Sequence of Events Recorder (SER) Module is a root-cause analysis tool for rapid response for problem resolution that is ideal for pinpointing the cause of a service disruption in very large complex power systems. WAGES Water, Air Gas, Electric, Steam PowerLogic energy and power management systems can provide instantaneous readings, alarm notifications, and graphical diagrams for monitoring electrical and piped utilities (Water, Air, Gas, Electric, Steam). APM Active Pager Module The PowerLogic Active Pager Module allows automatic paging to alphanumeric pagers, cell phones and PCs.
PowerLogic Engineers provide graphic solutions for realtime monitoring of power systems.
Automatic Throwover Systems Automatic selection of available utility or generator sources to maintain service continuity to connected loads. Load Shedding/Peak Shaving Control peak demand levels or ensure service continuity to critical load or operate breakers in accordance with user specified sequences and time delays such as bringing large motors online across several billing kw demand periods to avoid demand penalties. Load Preservation Fast acting sophisticated control systems designed to stabilize critical power systems to the greatest extend possible by monitoring frequency and power sources from utility plus generator capacity versus total circuit load.
System Integration
System Design and Engineering Our Square D Engineering Services solution specialists can work with you to design or upgrade your existing system to best achieve your energy and power management objectives and informational needs. With expertise in electrical systems, communications, and automatic control systems, we can integrate, install, and commission your system for optimal performance.
PowerLogic Engineers specialize in the design and setup of Emergency Power Supply Systems (EPSS).
System Design and Bill of Material Recommendations Power Monitoring and Control WAGES (Water, Air, Gas, Electric, Steam) Enterprise web-based monitoring Specification development, drawings, documentation Enclosure panel design and build Metering Connection Verification/Testing Power distribution automation On-Site Installation Assistance, Component Configuration & Startup Turn-key project management Third Party Device and communication interfaces Configured Workstations, User Software Interfaces Interactive Graphic Design to mimic facility layout, one-lines, equipment status Custom Software, Reports & Applications Billing and Paging POWER MONITORING AND CONTROL
For additional information, contact your nearest Square D / Schneider Electric office.
PowerLogic Engineers design power control systems that meet your operational requirements.
4-21
PowerLogic
Assemblies include meters & devices wired to terminal blocks, disconnects and shorting blocks Tailored to any system voltage :
208/120V, 480/277V & 600/347V Wye 240V, 480V & 600V Delta Utilization of PT's required for higher voltage levels
Wall mountable and easy to install using concealed holes in the back of the enclosure. Complete with necessary documentation and mounting hardware for quick and easy installation Carbon steel construction, with industry standard ANSI 61 gray powder coat finish Equipped with concealed hinged door, and universal pad-lockable latch. Custom engraved nameplates available for all units.
Table 4.33:
Available Meter Types PM 810, 820, 850 & 870 CM 3250 & 3350 CM 4250 & 4000T ION 6200 ION 7300, 7330 & 7350 ION 7550 & 7650
Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications Available with 1 - 4 meters per panel. Serial & Ethernet Communications are options for all units EGX & ION RTU Communication Enclosures with 1-4 devices per panel also available
Service Entrance/Utility Socket Enclosure Type 3R, UL & CUL 508A Listed
Available for ION8600 only, with up to 3 Digital Inputs and 4 Digital Outputs Supports Single Voltage Source only for Indoor & Outdoor (Type 3R) applications. Units are Ring Type with removable cover. Available with 1 meter per panel. Serial & Ethernet Communications options available. Supports Form 9S, 35S, 36S, 39S and 76S configurations. Options available for remote mounted CTs Options available for integrated, bar type CTs Optional Test Switch.
Additional engineered to order products are available for a wide variety of design solutions.
Switchgear Transfer Control Panels Generator Control Panels Load Shed Control Panels Sequence of Events Recording (SER) Panels Control System Mimic Panels Lighting Control Interface Panels Programmable Logic Controller (PLC) Control Panels (Hot Standby, Relay Control, Data Concentration etc. ...) Emergency Power Supply Systems (EPSS) Control Panels Water, Air, Gas, Electrical, and Steam (WAGES) Monitoring Panels Input Status Monitoring & Alarming Panels Remote Annunciator Control Panels Remote Operator Control Panels Serial, Ethernet, and Cellular Wireless Systems Server Rach and Network Equipment (Servers, Switches, UPSs) for Energy Management Systems. Industrialized PCs, Touch Screens (Magelis), and Human Machine Interfaces (HMIs) with Custom System Graphics. Designed to fit any environment Indoor (Type 1 & 12) & Outdoor (Type 3R & 4) applications
4
POWER MONITORING AND CONTROL
For additional information and pricing please contact your local PowerLogic sales specialist or PowerLogic Inside Sales Support at 1-866-466-7627. Enclosure pricing and literature available for download on our website at www.powerlogic.com/products/enclosures. To better serve you please have the following information on hand when calling.
4-22
Enclosure type (Indoor or Outdoor) and Environment details (Corrosive or Non-Corrosive) Power System Voltage Level and Type (Direct Current (DC) or Alternating Current (AC)) Digital & Analog Input and Output requirements Device Type and Quantity per enclosure Ethernet and Serial Communication Requirements For Drawout Retrofits, need existing cradle type (i.e. GE, Westinghouse, etc.)
2009 Schneider Electric All Rights Reserved
Priority Support: Excellent Service, Free Software Upgrades, Training Discounts & More!
Latest PowerLogic SMS and ION software upgrades to ensure up-to-date systems Direct access to expertise for quick issue resolution More efficient PowerLogic SMS and ION system utilization Higher reliability Improved productivity and personal efficiency on the job
Direct email (4-hr response time) and toll-free 800 number support for prompt response to urgent or non-urgent requests from highly trained support engineers. Hours of service 7:30am to 7pm US Central time PowerLogic Tenant Metering software upgrades at no charge Proactive notification of software service packs and fixes Remote diagnostics support engineer can troubleshoot any issues of the TMS system remotely without the customers help.
Premium Support: Priority + Proactive System Checks + Sr. Technician Assigned to your site
Choose Premium Support when you need to . . .
Remote eServices
Let expert Square D technicians ensure high-quality performance in your PowerLogic SMS and ION system by performing remote, online services through our secure WEB EX Portal. Services include
Enhance your PowerLogic SMS and ION system's operation with single-sourced pro-active problem identification, solutions recommendations and change management skills Partner with technical experts who help coordinate support, provide hands-on assistance, and share knowledge and know-how with you Obtain personalized services tailored to your business environment and objectives Take advantage of remote software upgrade capabilities Anticipate and communicate necessary change
PowerLogic 7x24 support provides 1-hour phone response by senior support engineer during off-hours. Additionally, 4-hour response (max) for remote connection to customer system for advanced troubleshooting.
Real Time Maintenance Option Real time maintenance provides real-time server monitoring to proactively alert assigned PREMSUP engineer of any issues immediately.
Installations, upgrades, & software patches System device setup & configuration along with alarming & historical trending Graphical Screen Development Remote, Online System Maintenance Software Updates - Patches & Upgrades PC Checks - Hard Disk Space, Network & DB Configurations, Viruses, etc. PowerLogic or ION Software Checks Communications, Data Logging, & Task Execution E-mailing system scorecard & maintenance recommendations One-on-one training on system software features Power Quality (PQ) & Energy Usage Analysis
By Quote By Quote
PowerLogic ION Core Classes PowerLogic ION Enterprise Fundamentals PowerLogic ION Enterprise Programmer PowerLogic ION Enterprise Administrator PowerLogic ION Enterprise Overview PowerLogic ION Program Overview PowerLogic ION Enterprise Customer Site Training PowerLogic ION Enterprise Refresher
PL1T
Discount Schedule
4-23
Correspondence Courses PowerLogic Fundamentals PowerLogic SMS Core Classes PowerLogic SMS fundamentals PowerLogic SMS fundamentals Bundle (Includes 3000PLUC120CR) PowerLogic System Installation & Troubleshooting PowerLogic SMS Administrator Target Application Courses Critical Power and Power Quality Energy Management with Advanced Reporting Regional SMS Overview SEPAM Industrial M.V. Relay Applications Regional SMS Overview Bundle (Includes 3000PLUC120CR) Customer Site Training System Manager Customer Site Training
3000PLUC120CR 3000PLUC200 3000PLUC205 3000PLUC100 3000PLUC300 3000PLUC140 3000PLUC230 3000PLUC190 3000PLU1SEP 3000PLUC195 3000PLUCSite 3000PLUCSITE
350.00 2150.00 2350.00 2150.00 2150.00 1400.00 1400.00 1800.00 2150.00 2050.00
Sepam Series
80, 40, and 20 Series
The Sepam family of digital protection relays, Series 20, 40 and 80, is the newest generation of Sepam relay, a time tested product with a 20-year worldwide history. Modular relay design allows quick and easy future upgrades to communications, digital I/O, analog output or temperature acquisition. The 64x128 bit, graphic LCD display and keypad permit relay setting of Series 20 and 40 without a PC. Comprehensive self-testing provides assurance of readiness to protect. The Sepam family also has exceptional withstand to environmental electromagnetic disturbances. An optional 128 x 240 LCD display for the Series 80 relay can show an animated one-line with front panel control. Table 4.35: Quick Select Guide
Capacitor Bank Feeder or main (Substation) Transformer Generator
Standard footprint for enhanced protection of Mains/Feeders, Transformer, Motor, Generator, Capacitor, Bus Applications Differential protection of transformer or machine transformer units Differential protection of motors and generators Protection for mains and ties and important feeders including pre-programmed transfer schemes Increased metering capabilities I, V, E, P, PF, THD, vector diagram Expanded logic equation capabilities (an option for Logipam PLC ladder logic) Setting software with graphical assistance, optional mimic-based display Battery backup for historical and fault waveform data retention, wide range DC control power Two rear communication optional Includes all Series 20 and Series 40 features
Motor
Bus
Criteria Radial (51, 51N, 46) Long feeders (67N) Closed loop (67N, 67) Parallel mains [transf] [sources] (67N, 67) Sync-check required (25)(67N, 67) Solid or low/high impedance (51N) Ungrounded or compensated (67N/NC) Basic Feeder [Transf][Motor]
Selection S23 T23 M20 G40 B80 C86 S41 S42 S42 T42 S82 T82 G82 G82 B80 M41
Network structure
Grounding system
S23 T23 M20 G40 S41 T42 M41 G82 S23 T23 M20 G40 S40 T40 M41 G40 B21 S84 B22
Compact standard footprint (< 4deep) for enhanced protection of Mains/Feeders, Transformer, Motor, Generator Applications Directional overcurrent protection for dual mains and ties and closed loop feeders Current and voltage inputs I, V, E, P, PF Setting software with Boolean logic equation assistance CT/VT and Trip Circuit supervision Sixteen seconds of fault recording, last 5 trip reports, and last 200 time-tagged alarms Rear communication port for interface to optional communications modules Includes all Series 20 features
Protection
Voltage/frequency (27/59/81) ROCOF (81R) Advanced Fdr/Main[Transf] [Motor][Gen] Thermal overload (49)cable Thermal O/L (49)- capacitor bank Differential (87T) Machine differential (87M) Machinetransformer unit differential
S41 T82 M81 G82 B83 S81 C86 T87 M87 G87 M88 G88 S23 T23 M20 B21 S40 T40 M41 G40 B80 B83 T87 M87 G87 S80 T81 M81 G82 B80 T23 M20 G40 T40 M41 G40 S23 S80 S23 S40 S80 S23 S80 T23 T81 T23 T40 T81 T23 T81 M20 M81 M20 M41 M81 M20 M81 G40 G82 G40 G40 G82 G40 G82 B21 B80 B21 B80 B80 B21 B80
I V, f I, V, f, P E , Metering I, V, V, f, P, E I, I, V, F, P, E THD-I, THD-V <8 RTDs of same type Temperature > 8 RTDs (< 16) or 2 types of RTDs < 10 I / 8 O I/Os > 10 I / 8 O and < 42 I / 23 O Control matrix Program logic Logic equation editor customization Ladder-logic software 1 Modbus port Modbus communication 2 Modbus ports
Backlit LCD graphic bitmap display Compact standard footprint (< 4deep) for basic protection of Mains/Feeders, Transformer, Motor, Bus (Voltage) Applications 16 inverse time overcurrent characteristic curves Setting software with offline file creation and download to relay Two 86 cycle records of fault recording, last trip fault values, and last 64 time-tagged alarms retained Provides trip diagnostic information for analysis of faults Self-test diagnostic ensures correct operation of relay and integrity of protection Wide range of control power inputs Display operation minimal training required for operation. Application specific design for Main/Feeder, Transformer, Motor, Bus (Voltage) zones Zone selective interlocking (ZSI) improved protection coordination Rear communication port for interface to optional Modbus communications modules, plus dual port module, optional protocols DNP3 and IEC60870-5-103, and also fiber optics Modular architecture Breaker diagnostics Two groups of current protection settings (logic input selectable) to allow reduced arc-flash hazard during maintenance operation
4
POWER MONITORING AND CONTROL
Note: Units in table depict least complex device types compliant with criterion.
4-24
Sepam Series
Selection Table
Table 4.36:
Series 80 Applications
Protection Application ANSI Code 50/51 50N/51N 50G/51G 50BF 46 49RMS 49RMS 49RMS 51C 64REF 87T 87M 67 67N/67NC 32P 32Q 37P 37 48/51LR 66 40 78PS 12 14 50V/51V 21B 50/27 27TN/64G2/64G 24 27D 27R 27 59 59N 47 81H 81L 81R 79 26/63 38/49T 25 S80 8 8 1 2 S81 8 8 1 2 2 S82 8 8 1 2 2 S84 8 8 1 2 2 T81 8 8 1 2 2 T82 8 8 1 2 2 T87 8 8 1 2 2 M81 8 8 1 2 2 M87 8 8 1 2 2 M88 8 8 1 2 2 G82 8 8 1 2 2 G87 8 8 1 2 2 G88 8 8 1 2 2 2 8 2 2 2 1 1 2 2 2 2 2 2 2 2 2 1 1 1 1 1 e e 1 1 1 1 1 e e 1 1 1 1 1 e e 2 2 2 2 2 2 2 2 2 2 1 2 2 1 2 2 1 2 2 2 1 2 2 1 1 2 2 2 1 2 1 2 2 2 1 B80 8 8 1 2 B83 8 8 1 2 C86 8 8 1 2
Phase overcurrenta Ground fault / Sensitive ground faulta Breaker failure Negative sequence / unbalance Thermal overload for cables Thermal overload for machinesa Thermal overload for capacitors Capacitor bank unbalance Restricted ground fault Two-winding transformer differential Machine differential Directional phase overcurrenta Directional ground faulta Directional active overpower Directional reactive overpower Directional active underpower Phase undercurrent Excessive starting time, locked rotor Starts per hour Field loss (underimpedance) Pole slip Overspeed (2 set points)b Underspeed (2 set points)b Voltage-restrained overcurrent Underimpedance Inadvertent energization Third harmonic undervoltage/100% stator ground fault Overfluxing (V / Hz) Positive sequence undervoltage Remanent undervoltage Undervoltage (L-L or L-N) Overvoltage (L-L or L-N) Neutral voltage displacement Negative sequence overvoltage Overfrequency Underfrequency Rate of change of frequency Recloser (4 cycles)b Thermostat / Buchholzb Temperature monitoring (16 RTDs)c Synchronism-checkd
2 2 4 4 2 2 2 4 e
2 2 4 4 2 2 2 4 e
2 2 4 4 2 2 2 4 e
4 2 2 4 2 2 2 4 2 e
2 2 4 4 2 2 2 4
2 2 4 4 2 2 2 4
2 2 2 4 4 2 2 2 4
2 2 4 4 2 2 2 4
2 2 4 4 2 2 2 4
2 2 4 4 2 2 2 4
1 1 e e 2 1 1 2 2 2 2 4 4 2 2 2 4
1 1 e e 2 1 1 2 2 2 2 4 4 2 2 2 4
1 1 e e 2 1 1 2 2 2 2 4 4 2 2 2 4
4 2 2 4 2 2 2 4
4 2 2 4 2 2 2 4
4 2 2 4 2 2 2 4
e e e
e e e
e e e
e e
e e
e e e
e e
e e e
e e e
Table 4.37:
4-25
Application ANSI Code Phase overcurrenta 50/51 Voltage-restrained overcurrent 50V/51V 50N/51N Ground fault / Sensitive ground faulta 50G/51G Breaker failure 50BF Negative sequence / unbalance 46 Directional phase overcurrenta 67 Directional ground faulta 67N/67NC Directional active overpower 32P Directional reactive overpower 32Q/40 Thermal overloada 49RMS Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR/14 Starts per hour 66 Positive sequence undervoltage 27D/47 Positive sequence undervoltage 27D Remanent undervoltage 27R Phase-to-phase undervoltage 27 Phase-to-neutral undervoltage 27S Undervoltage 27/27S Overvoltage 59 Neutral voltage displacement 59N Negative sequence overvoltage 47 Overfrequency 81H Underfrequency 81L Rate of change of frequency 81R Recloser (4 cycles) 79 Temperature monitoring (8 or 16 RTDs)a 38/49T Thermostat / Buchholzb 26/63 Note: Numerals in table indicate number of protection setpoints a Protection functions with 2 groups of settings b Requires MES120 I/O module c Requires MET1482 RTD Input module d Requires MCS025 synch check module e Option
2 1 1 1
1 1 2
2 1 2 1 2 2 2 1 2 4 2 2 1 2
2 1 2 1 2 2 1 2 1
2 2 2 1 2 4 e e
2 2 2 1 2 4 e
2 2 2 1 2 4 e e e
2 2 2 1 2 4
2 2 2 1 2 4
2 2 2 1 2 4
e e
e e
Sepam Series
Table 4.38:
Model
Application Catalog No. $ Price Model S80 - Substation/feeder [current & voltage] SQ1S80A 3870.00 S81 - Substation/feeder [directional grd O/C] SQ1S81A 4060.00 S82 - Substation/feeder [directional ph & grd O/C] SQ1S82A 4180.00 S84 - Substation/main [separation/ load shed] SQ1S84A 4780.00 Series 40 T81 - Transformer [current & voltage] SQ1T81A 4130.00 T82 - Transformer [Dir. Ph & Grd O/C] SQ1T82A 4430.00 T87 - Transformer [Diff.-2 wdg) SQ1T87A 4880.00 M81- Motor [Dir. Grd O/C] SQ1M81A 3540.00 Series 80 M87- Motor [Mach. Diff.] SQ1M87A 3850.00 M88 - Motor [Transf. Diff.] SQ1M88A 4140.00 G82 - Generator [Dir. Watt & Var, Volt-Restr O/C] SQ1G82A 4170.00 G87 - Generator [Mach diff] SQ1G87A 4520.00 G88 - Generator [Transf diff] SQ1G88A 5522.00 Series 20 B80 - Bus [Main+1ph volt] SQ1B80A 4050.00 B83 - Bus [Tie +3ph volt] SQ1B83A 4250.00 C86 - Capacitor [4 step 2xWye banks] SQ1C86A 4125.00 a Replace A suffix with P to select the Pro version mimic display. (add $450 to list price)
Table 4.39:
Series 80 Series 40/20 x x x Digital I/O Module x x x x x x x x x Communication I/Fb Module x x x x x x x x x Other option modules, x x software, mounting plates x x x x x x Analog I/O Cables x x x x x x Ground Sensor CTs (mV out) x x x x Accessory Type Configure softwarec x x x x x x x x x x x x x
Selected sparesd
b c d
x x Includes CCA612 cable to relay rear port One s/w kit required per Series 80 order and recommended per Series 40/20 order To be ordered as spare or replacement
4
POWER MONITORING AND CONTROL
4-26
PL1
Discount Schedule
Series 80
Table 4.40:
Selection Example
Follow these steps: Example: Type Part Relay unit Memory module Digital I/O Communication module RTD Input Analog output Sync check (25) module Config S/W Cable for RTD I/F Modulle QTY 1 0 1 1 1 0 1 1 1 Catalog No. SP1T87A MMS020xxx MES120 ACE959 MET1482 MSA141 MCS025 SFT2841KIT CCA772 Description T87- Transformer [Diff.-2 wdg) Spare memory module 14 inputs + 6 outputs / 24-250Vdc RS485 4-wire Interface Module l 8 temperature sensor input module Analog output module (1 channel) Synch check module (includes cable CCA785) Setting / operating software kit 2m cable from remote display to base unit $ Price 4880.00 0.00 770.00 398.00 695.00 0.00 1410.00 543.00 51.00
PL1
Discount Schedule
4-27
Selection Sequence Select from Table 4.35 per system, features Table 4.32 & 4.33/4.34 Spare by application Select from Table 4.36 (as required) Select from Table 4.36 (as required) Select from Table 4.36 (as required) Select from Table 4.36 (as required) Select from Table 4.36 (as required) Select from Table 4.36 (as required) Select from Table 4.36 (as required)
PFC Capacitors
Class 5810
www.reactivar.com
FOR CURRENT INFORMATION
fixed low voltage capacitors are ideally suited for power factor correction applications where the load does not change or where the capacitor is switched with the load, such as the load side of a motor starter. ReactiVar fixed capacitors are best suited for applications where there are no harmonic currents or voltages present.
ReactiVar
Features:
Fixed Capacitors are best suited for use on electrical systems with no voltage or current harmonics.
Environmentally friendly: ReactiVar capacitors are constructed with a dry type metalized polypropylene capacitor element with no liquid dielectrics. There is no risk of fluid leakage or environmental pollution and no need for a drip pan. Higher overvoltage limit on Super Duty model which is suitable for lightly polluted network. Low Loss, Long Life: The design features less than 0.5W/kVAR losses, including discharge resistors. Attractive finish: Capacitor units feature a textured powder paint finish, ASA 61 gray. Units are constructed of 14 gauge steel and are suitable for floor or wall mounting.
Application Note: Capacitors are a low impedance path for the harmonic currents produced by variable frequency drives, motor soft starters, welders, computers, PLCs, robotics and other electronic equipment. These harmonic currents can be drawn into the capacitor causing it to overheat, shortening its life. Furthermore, the resonant circuit formed by shunt capacitors coupled with system inductances (motors and transformers) can amplify harmonic currents Table 4.41:
Kvar rating at 480V 6 8.5 10 12.5 15 16.5 20 25 27.5 30 33 35 40 45 50 60 65 70 75 80 90 100 125 150 175 200
and voltages in the electrical network. This amplification can cause nuisance fuse operation and/or damage to electrical equipment including capacitors and other electronic devices. If power factor correction in the presence of harmonics is required, please contact your nearest Square D/Schneider Electric sales office for assistance.
Table 4.42:
Kvar rating
a b c d
at 480V Catalog number $ Price Enclosurebc 6 PFCDS4006 1394.00 1 8 PFCDS4008 1537.00 1 9.5 PFCDS4010 1621.00 1 13 PFCDS4013 1828.00 1 16 PFCDS4016 2000.00 1 17.5 PFCDS4017 2113.00 1 20 PFCDS4020 2225.00 1 22.5 PFCDS4022 2358.00 2 25 PFCDS4025 2490.00 2 27.5 PFCDS4027 2785.00 2 30 PFCDS4030 2938.00 2 35 PFCDS4035 3162.00 2 40 PFCDS4040 3547.00 2 45 PFCDS4045 3789.00 3 50 PFCDS4050 4026.00 3 60 PFCDS4060 5979.00 4 70 PFCDS4070 6438.00 4 75 PFCDS4075 6670.00 4 80 PFCDS4080 7062.00 5 90 PFCDS4090 7848.00 5 100 PFCDS4100 8675.00 5 115 PFCDS4115 10034.00 5 Consult local electrical codes for proper sizing of molded case circuit breaker frame or disconnect switch rating. Unit size 1, 2 and 3 can be wall mounted. Order PFCDBR2 mounting bracked separately. Refer to table 4-45 for dimensions. Conductor should be copper and rated 90 C min. Refer to local electrical codes for proper wire size.
4
POWER MONITORING AND CONTROL
4-28
DE2C
Discount Schedule
PFC Capacitors
Class 5810
www.reactivar.com
FOR CURRENT INFORMATION
In addition to the comprehensive Multiple Protection System designed into the New ReactiVar fixed, low voltage capacitors, fused units feature a fast acting current limiting fuse in each phase. Blown fuse indicators are included as standard on indoor (NEMA Type 1) enclosure. While fuses are not required to protect the capacitor elements, external over current protection may be required by the local electrical code for protection of the conductors feeding the capacitors. Consult your local electrical code for installation instructions. Table 4.43:
Kvar rating at 480V 6 8.5 10 12.5 15 16.5 20 25 27.5 30 33 35 40 45 50 60 65 70 75 80 90 100 125 150 175 200
Table 4.44:
Kvar rating
a b c d
Recommended copper wire sized at 480V Catalog number $ Price Enclosurebc at 480V AWG 6 PFCDS4006F 1814.00 1 7.7 14 8 PFCDS4008F 1959.00 1 10.4 12 9.5 PFCDS4010F 2047.00 1 11.5 12 13 PFCDS4013F 2253.00 1 15.4 10 16 PFCDS4016F 2424.00 1 19.2 8 17.5 PFCDS4017F 2538.00 1 20.8 8 20 PFCDS4020F 2651.00 1 23.1 8 22.5 PFCDS4022F 2783.00 2 26.9 8 25 PFCDS4025F 2914.00 2 30.8 6 27.5 PFCDS4027F 3207.00 2 33.5 6 30 PFCDS4030F 3430.00 2 36.2 6 35 PFCDS4035F 3586.00 2 42.3 4 40 PFCDS4040F 3974.00 2 49.3 4 45 PFCDS4045F 4319.00 3 53.9 4 50 PFCDS4050F 4662.00 3 61.6 3 60 PFCDS4060F 6613.00 4 73.1 2 70 PFCDS4070F 7498.00 4 84.7 1 75 PFCDS4075F 7940.00 4 90.1 1/0 80 PFCDS4080F 8333.00 5 97.8 1/0 90 PFCDS4090F 9118.00 5 107.8 2/0 100 PFCDS4100F 9896.00 5 120.9 3/0 115 PFCDS4115F 11220.00 5 138.6 4/0 Consult local electrical codes for proper sizing of molded case circuit breaker frame or disconnect switch rating. Unit size 1, 2 and 3 can be wall mounted. Order PFCDBR2 mounting bracket separately. Refer to table 4-45 for dimensions Conductor should be copper and rated 90 C min. Refer to local electrical codes for proper wire size.
Table 4.45:
Size No. 1 2 3 4 5
DE2C
Discount Schedule
4-29
PFC Capacitor Banks Low Voltage (LV) Standard Automatic Capacitor Banks with Main Lugs or Main Breakers
The AV4000 and AV5000 standard automatic power factor correction banks are designed for centralized power factor correction to supply varying amounts of reactive power required to compensate for changing load conditions. The AV4000 and AV5000 banks are ideally suited for facility electrical distribution systems with TDD (total harmonic current distortion) < = 5% and THD(V) (total harmonic voltage distortion) < = 3%. An advanced microprocessor-based recative power controller measures plant power factor via a single remote CT. Plus, it switches capacitor modules in and out of service to maintain a userselected target power factor.
The AV4000 and AV5000 are suitable for use where harmonic generating loads are less than 15% of the total connected load (AV5000 shown here).
Class 5830
www.reactivar.com
FOR CURRENT INFORMATION
Main Features:
Application Assistance:
The Schneider Electric Power Quality Correction Experts provide engineering assistance for the application of capacitors in harmonic rich environments. Specialists at Schneider Electric can assess the likelihood of application problems and arrange for more detailed study if required. Solutions can include computer modeling and system simulation. Our application engineers can make all the arrangements for system studies, custom engineering, installation and commissioning, as required by the application. Contact Schneider Electric sale office for detail equipment quotation assistance. For dimension reference, see page 4-33.
Modular construction; free standing QED switchboard enclosures contain up to 500 kVAR per section and allow for easy future expansion Standard offering available up to 400 Kvar at 208/240 Vac, 1000 kVAR at 480 or 600 Vac Main lugs or main breaker section at your choice Dry capacitor element design eliminates risk of fluid leakage, environmental hazard and drip pans Capacitor rated contactors are designed specifically for the switching of capacitive currents and feature a patented capacitor precharge circuit that exceeds air-core reactor transient dampening Three different microprocessor controller options provide a choice in functionality and control sophistication Backlit display on controller displays actual PF, alarms, number of steps energized and much more Rugged design units are constructed with removable steel panels over heavy gauge steel frame Available in Type NEMA 1 indoor enclosures Indoor units are finished with ASA 49 grey textured paint finish For application up to 200 kVAR max., 480 V (main lugs, top entry only), the AV4000 offers compact and cost effective alternative.
Equipment specification:
Voltage: Kvar rating: Ambient temperature: Average temperature limit: Elevation: Humidity: Overvoltage limit: Dielectric withstand test level: Overcurrent limit: Incoming: Main lug: Main breaker: Enclosure rating: Color: 240, 480, 600 Vac standard, 208, 380, 415 Vac available up to 1000 Kvar (depending on voltage rating) -5C to 40C <40C within 24 hours, <30C over 1 year <=1800 meter 0-95% non-condensing 110% maximum 2.15 times rated voltage or 1000 V, whichever is higher for 10s 130% maximum Top (standard), bottom, side. Mechanical standard, compression optional PowerPact with Micrologic trip unit. LI standard, LSI available NEMA 1 standard ANSI 49 standard, ANSI 61, ANSI 70 optional
Table 4.46:
Current Rating of Bus/Cable Amperes 300 400 500 600 750 800 1000 1200 1500 1600 2000 2500 3000 3500 4000 5000 6000 Rating Code Window Size 7" x 4" Size Code 11" x 4" Size Code c c c c 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 07 11 N/A 11 N/A 11
4
POWER MONITORING AND CONTROL
Sub 600 kVAR Sub Feed Automatic Feed Capacitor Bank
Sub Feed
Sub Feed
0300 0400 0500 0600 0750 0800 1000 1200 1500 1600 2000 2500 3000 3500 4000 5000 6000
4-30
DE2C
Discount Schedule
www.reactivar.com
FOR CURRENT INFORMATION
Class 5860
Low Voltage Anti-Resonant and Filtering Automatic Capacitor Banks with Main Lugs and Breaker
ReactiVar AV6000 anti-resonant and AV7000 harmonic filtering automatic switched capacitor banks are specifically designed for networks containing harmonic energies which would otherwise damage standard fixed or automatic capacitor banks. The problem: Harmonics are a natural by-product of non-linear loads such as variable frequency drives, motor soft starters, welders, uninterruptable power supplies, robotics, PLCs and other electronic devices. Harmonics introduce higher-than-60 Hz current and voltage components into the electrical distribution system. Capacitors are a low impedance path for these higher frequency components and thus will absorb these harmonic energies. Combinations of capacitors and system inductances (motors and transformers) can form series and parallel tuned circuits which can resonate at certain frequencies. The harmonics produced by non-linear loads can excite a standard capacitor bank into resonance. The resonance can magnify currents and voltages, causing system wide damage and equipment failure. This problem is growing in prevalence.
Main Features
Standard offering available up to 1200 kvar at 480 or 600 Vac Capacitor modules are designed with higher than standard voltage and current ratings to provide long life on systems with high harmonic energies. Reactors are designed to operate at 115C rise over a maximum 40C ambient temperature. In addition to the standard features provided in the AV5000 systems, the reactors in the AV6000 have an embedded thermistor temperature detector. The stage will shut down and annunciate if the reactor should overheat, usually a result of excessive harmonic energies
Application Assistance
The Schneider Electric Power Quality Correction Experts provide engineering assistance for the application of capacitors in harmonic rich environments. Specialists at Schneider Electric can assess the likelihood of application problems and arrange for more detailed study if required. Solutions can include computer modeling and system simulation. Depending on the network, the solution may include de-tuned banks (AV6000) or fully filtered banks (AV7000). Our application engineers can make all the arrangements for system studies, custom engineering, installation and commissioning, as required by the application. Contact Schneider Electric sales office for detail equipment quotation assistance. For dimension reference, see page 4-33.
Equipment specification:
Voltage: Kvar rating: Ambient temperature: Average temperature limit: Elevation: Humidity: Overvoltage limit: Dielectric withstand test level: Overcurrent limit: Incoming: Main lug: Main breaker: Enclosure rating: Color: 480, 600 Vac standard, 380, 415 Vac available up to 1200 Kvar (depending on voltage rating) -5C to 40C <40C within 24 hours, <30C over 1 year <=1800 meter 0-95% non-condensing 110% maximum 2.15 times rated voltage or 1000 V, whichever is higher for 10s
POWER MONITORING AND CONTROL
130% maximum Top (standard), bottom, side. Mechanical standard, compression optional PowerPact with Micrologic trip unit. LI standard, LSI available NEMA 1 standard ANSI 49 standard, ANSI 61, ANSI 70 optional
DE2C
Discount Schedule
4-31
www.reactivar.com
FOR CURRENT INFORMATION
Main Features:
Standard offering up to 1350 Kvar at 480 or 600 Vac Transient free switching of capacitor steps Electronic switching elements yield an unlimited number of switching operations Three different microprocessor controller options provide a choice in functionality and control sophistication Backlit display on controller displays actual PF, alarms, number of steps energized and much more Heavy duty dry capacitor element design provides no risk of fluid leakage, no environmental pollution and no need for drip pans The Reactors have an embedded thermistor temperature detector. The stage will shut down and annunciate if the reactor should overheat, usually a result of excessive harmonic energies Units are constructed with removable heavy duty steel panels over a 12 gauge steel frame. Indoor Type 1 units finished with ASA 49 gray polyester paint. Other colors available.
Application Assistance
The Schneider Electric Power Quality Correction Group provides engineering assistance for the application of capacitors in harmonic rich environments. Specialists at Square D can assess the likelihood of application problems and arrange for more detailed study if required. Solutions can include computer modeling and system simulation. Our application engineers can make all the arrangements for system studies, custom engineering, installation and commissioning, as required by the application. Contact Schneider Electric sales office for detail equipment quotation assistance. To facilitate application assistance, please have the following information available:
12 months of utility billing information A single line diagram of the network showing the nature of loads (e.g. 150 hp FVNR starters; 200 hp VFD; etc.) Transformer(s) kVA rating and percent impedance (%Z) Primary & secondary voltages Location of utility metering Size, type and location of any existing capacitors
Equipment specification:
4
POWER MONITORING AND CONTROL
Voltage: Kvar rating: Load change response time: Ambient temperature: Average temperature limit: Elevation: Humidity: Overvoltage limit: Dielectric withstand test level: Overcurrent limit: Incoming: Main lug: Main breaker: Enclosure rating: Color:
480, 600 Vac standard, 380, 415 Vac available up to 1350 Kvar (depending on voltage rating) <10 seconds -5C to 40C <40C within 24 hours, <30C over 1 year <=1800 meter 0-95% non-condensing 110% maximum 2.15 times rated voltage or 1000 V, whichever is higher for 10s 130% maximum Top (standard), bottom, side. Mechanical standard, compression optional PowerPact with Micrologic trip unit. LI standard, LSI available NEMA 1 standard, N3R available ANSI 49 standard, ANSI 61, ANSI 70 optional
4-32
DE2C
Discount Schedule
www.reactivar.com
FOR CURRENT INFORMATION
24 MIN. CLEARANCE
23.50
8.05
TOP VIEW
44.28
36 MIN. CLEARANCE
23.50
21.43
Figure 1AV4000
24 MIN. CLEARANCE
32.00
8.02
24 MIN. CLEARANCE
32.00
32.00
TOP VIEW
60.00
60.00
SUPPLIED BUT FIELD FITTED CABLE ENTRY BOX C/W REMOVABLE CABLE ENTRY PLATE QTY (1) 18.00 REMOVABLE LIFTING LUGS
18.00
SUPPLIED BUT FIELD FITTED CABLE ENTRY BOX C/W REMOVABLE CABLE ENTRY PLATE QTY (1) REMOVABLE LIFTING LUGS AIR FLOW
91.50
66.26
32.00
35.00
32.00
32.00
35.00
Figure 3AT6000
DE2C
Discount Schedule
4-33
www.reactivar.com
FOR CURRENT INFORMATION
Power factor correction, harmonic mitigation, and voltage support in medium voltage electrical systems. Custom engineered for steady and rapidly fluctuating loads. ReactiVar Medium Voltage Fixed Power Factor Capacitors
The ReactiVar MVC fixed capacitors are ideally suited for power factor correction in applications where the load does not change or where the capacitor is switched with the load, such as the load side of a motor contactor. ReactiVar capacitors are available up to 300 kVAR as individual units, and up to 600 kVAR in banks. Unfused or fused (2 fuses) assemblies are available. Other ranges available upon request.
Features:
MVC systems are suitable for power factor correction of steady harmonic-free motor loads.
Fused and unfused applications Standard rating up to 600 kVAR, 4800 V (for specials, consult factory) Metallized polypropylene film capacitors for low dielectric loss Internally mounted discharge resistors Operating temperature range of 25C to +45C Built to applicable NEMA, IEEE, and IEC standards Available in indoor (Type 1/12) and outdoor (Type 3R) enclosures Painted ASA 61 gray
Lead time: 1214 weeks typical (consult factory for committed delivery) Prices & assistance: Call PQc Group at (905) 678-6699 or email pqc@ca.schneider-electric.com
Features:
MV5000 systems are suitable for use where harmonic generating loads are less than 15% of the total connected load. MV6000 systems are suitable for use where harmonic generating loads are less than 50% of the total connected load. MV7000 systems are suitable for use where harmonic generating loads exceed 50% of the total connected load. MVHVC High-Speed compensation systems are designed for compensation of rapidly fluctuating loads
Standard metal enclosures available up to 20,000 kVAR, 5/15 kV, 50/60 Hz The Square D HVL load interrupter switch (fused or unfused) Externally fused Merlin Gerin PROPIVAR (or equivalent) or Cooper capacitors with excellent life due to high temperature withstand, small temperature rise, chemical stability, overvoltage and overcurrent withstand. (Internally fused capacitor available upon request) Three-bushing capacitor cells connected in delta available up to 5 kV. Two-bushing capacitor cells connected in ungrounded wye for higher voltages Current limiting capacitor fuses with blown fuse pop-up indicators current limiting reactors in multistage-step MV5000 standard systems to limit high capacitor inrush currents Iron core reactors in MV6000 de-tune banks to prevent parallel resonance Heavy-duty iron core reactors in MV7000 filtered banks for effective 5th harmonic filtering. Available in Type 1 indoor and 3R outdoor enclosure types Key interlocking system forces sequential operation of the controls, non-load break switch (or circuit breaker) and ground switches Superior Square D Varlogic microprocessor based power factor controller The Merlin Gerin SEPAM protective relaying.
Lead time: 1620 weeks typical (consult factory for committed delivery) Prices & assistance: Call PQc Group at (905) 678-6699 or email pqc@ca.schneider-electric.com
4
POWER MONITORING AND CONTROL
4-34
DE2C
Discount Schedule
www.reactivar.com
FOR CURRENT INFORMATION
Class 5820
The problem:
High levels of harmonics generated by non-linear loads can have significant negative impact in the facility electrical system. It can cause malfunction of the equipment, disrupt plant operation, thus, resulting in loss of productivity.
Harmonic filtering:
The AccuSine Power Correction System (PCS) is an Active Harmonic Filter (AHF) that actively injects opposite harmonics current on the source side of the load and it:
Decreases harmonic related overheating of cables, switchgear and transformers Reduces downtime caused by nuisance thermal tripping of protective devices Increases electrical network reliability and reduces operating costs Corrects to the 50th harmonic, reduce harmonics level to meet IEEE 519, IEC 61000 3-4, and UK G5/4-1 standards. Compensates entire network or specific loads depending on installation point
Other Features:
Independent phase compensation UL, CE, ABS, and CSA approved Parallel connection allows for easy retrofit and installation of multiple units for large networks Response to load fluctuations begins in 100 microseconds with 1/2 cycle for full response to step load changes 50, 100 and 300 A models for 208480 V. Other voltages available.
PCS050D5N1 34904.00 PCS050D5N12 53738.00 PCS050D5IP30 54299.00 50 34.6 41.6 50/60 N/A PCS050D5IP54 57553.00 PCS050D5CE30b 59516.00 PCS050D5CE54b 62770.00 36 PCS100D5N1 55131.00 PCS100D5N12 66777.00 PCS100D5IP30 71897.00 100 69.2 83.1 50/60 N/A PCS100D5IP54 78948.00 PCS100D5CE30b 74449.00 PCS100D5CE54b 78679.00 108 PCS300D5N1 110301.00 PCS300D5N12 132341.00 PCS300D5IP30 133670.00 300 207.8 249.4 50/60 PCS300D5IP54 142628.00 N/A PCS300D5CE30b 144502.00 PCS300D5CE54b 161035.00 a Other voltages available. Contact your nearest Schneider Electric sales office. b CE Certified models meet EMC Directive 89/336 EEC. c Floor Standing models include a door-interlocked disconnect.
NEMA 1 Wall Mount Bottom NEMA 12 IP30 IP54 Floor Standingc Top or Bottom 75 IP30 (CE Certified) IP54 (CE Certified) NEMA 1 Wall Mount Bottom 64.9 NEMA 12 IP30 IP54 Floor Standingc Top or Bottom 75 IP30 (CE Certified) IP54 (CE Certified) NEMA 1 Top NEMA 12 IP30 Floor Standingc 75 IP54 Top or Bottom IP30 (CE Certified) IP54 (CE Certified)
DE2C
Discount Schedule
4-35
www.reactivar.com
FOR CURRENT INFORMATION
The Hybrid VAR Compensator (HVC) is ideally suited for industrial facilities with power quality or production problems caused by rapidly changing load demands typical of highly cyclical loads such as welders, mining conveyors and heavy stamping machines.
Main Breaker (Optional)
The problem:
Traditional capacitor systems have a minimum response time of five to ten seconds for load fluctuations. As a result of this limitation, uncompensated faster loads can produce voltage instability, voltage flicker, increased losses and poor power factor which reduces the electric supply capacity. Problems can often be seen inside the facility, on the utility feeder to the facility or in neighboring facilities. Problems can include:
AccuSine EVC
Poor weld quality or reduced weld line productivity (due to restrikes or interlock weld controls) Failure to start motor loads (due to voltage sag on startup) Undervoltage tripping of sensitive loads (Robots, PLCs, VFDs) Lighting flicker and/or HID lighting shutdown Overloaded distribution equipment (cyclical current pulses may exceed the rated current of the distribution equipment) Poor power factor and associated utility demand charges High harmonic levels
100 kVAR
100 kVAR
The Hybrid VAR Compensator is ideally suited for power factor correction and voltage sag support in many applications where conventional systems are not suitable: One cycle or less for full response Infinite VAR resolution Compensates for large inductive inrush currents Transient free compensation Improves voltage regulation Reduces flicker
HVC systems can alleviate any of the problems created by cyclical loads that require large amounts or reactive power for short duration.
Three CTs required for networks with line-neutral loads. Two remote current transformers required for three phase loads. For installations requiring parallel connection of multiple AccuSine for increased correction capacity, special considerations may be required. Contact the Schneider Electric Power Quality Correction Group for details. Table 4.48:
A (ID) D (OD) 1000 CT1000SC 642.00 4.0 6.5 3000 CT3000SC 800.00 6.0 8.5 5000 CTFCL500058 1082.00 8.0 10.5 Note: Rectangular CTs also available; contact PQC group. Ampacity Catalog No. $ Price Dimensions (IN) Weight (lbs.) 3.5 4.25 5.5 Accuracy 1% 1% 1% Burden Capacity 10 VA 45 VA 45 VA Secondary Current 5A 5A 5A
4
POWER MONITORING AND CONTROL
1.50
38
4-36
DE2C
Discount Schedule
Table of Contents
Section 5
Lighting Control Product Overview
One Line Overview 5-38, 5-39
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
5-40 5-41 5-42 5-43 5-44 5-45 5-465-48 5-48 5-49 5-50 5-51 5-52 5-53 5-54, 5-55 5-56 5-57 5-58
Multi Room Audio Hand Held Remote Controls Thermostats Sensors Input Units Relays Dimmers System Units Enclosures Area Lighting Panels Software
Occupancy Sensors
Wall Switch Occupancy Sensors Ceiling Mount Occupancy Sensors Wall Mount Occupancy Sensors Fixture Mounted Sensors and Controls 5-60 5-61 5-61 5-62
5-1
Overview
Lighting Control
www.schneider-electric.us
Schneider Electric Occupancy Sensors, Powerlink and C-Bus control systems can be used independently or combined to provide the optimal lighting control solution for your home or business
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
5-2
Overview
www.schneider-electric.us
Lighting Control
5-3
C-Bus
Neo Keypads
Lighting Control
Class 1250
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
Neo Keypads offer localized finger-tip control of lighting and other electrical devices. With over 1,000 custom color combinations available, these elegant keypads compliment any decor. Requires plaster mud ring or single gang box with minimum internal width of 2.05.
Button configurations include multi-point switching and dimming, master ON/OFF switching, and scene settings Scene control includes up to forty group addresses per keypad. Larger scenes are possible by sharing memory among multiple keypads Independent timers available for each button Standard built-in infrared receiver permits keypad control at a distance with an optional infrared handheld remote Dual-color LED windows on each button can glow in cool blue, orange, or combinations of both, indicating when a controlled device is ON or OFF Auto fallback can dim button LEDs at a set time after the last key press Locator LEDs can illuminate the top and bottom of the button area in cool blue, helping a user find the keypad in dim light or help the installer find the correct keypad when commissioning Clean-lined low-profile keypads are wall mounted without external fittings Optional button covers have ID windows, enabling quick identification of lighting scenes or controlled devices Distinctively designed multi-layer cover plate consists of button covers, an outer surround, and an inner surround Color schemes are easily customized and modified to suit personal taste or the dcor
2 Button Keypad 4 Button Keypad Brushed Aluminum w/Slate: SLC505(2)NLGB Cream: SLC505(4)NLCM
Color Chart
Color Number Slate 1 White 2 Cream 3 Soft Gray 4 Desert Sand 5 Black 6 Brown 7 Brushed Aluminuma 8 Golda 9 a Only the inner surround is available in Brushed Aluminum and Gold.
Table 5.3:
Catalog No. Catalog Description $ Price SLC5050IS( ) Neo, inner surround, (5pk) 152.00 SLC5050OS( ) Neo, outer surround, (5pk) 46.00 SLC5052NRP( ) Neo, button covers, 5052L, (5pk) 60.00 SLC5054NRP( ) Neo, button covers, 5054L, (5pk) 60.00 SLC5058NRP( ) Neo, button covers, 5058L, (5pk) 60.00 SLC5052NRI( ) Neo, button covers, with ID window, (10pk) 82.00 Note: Accessories have unique catalog numbers. To specify colors for them, (see Table 5.1) add the color number to the end of the catalog number (Table 5.3). For example, SLC5052NR2 is the catalog number for a white button cover.
5-4
DE-8
Discount Shedule
C-Bus
www.schneider-electric.us
Saturn Keypads
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
Saturn Keypads incorporate a unique glass cover plate that creates a distinctive appearance. By virtue of the variety of button configurations available, one compact Saturn keypad can take the place of many single operation switches, ON/OFF toggles, dimmers, and timers. Available in two-, four-, or six-button keypads, Saturns modern style is complemented by orange and blue LEDs that can instantly show the status of controlled devices. Requires plaster mud ring or single gang box with minimum internal width of 2.05.
Button configurations include multi-point switching and dimming, master ON/OFF switching, and scene settings Scene control includes up to forty group addresses per keypad. Larger scenes are possible by sharing memory among multiple keypads Independent timers available for each button Dual-color LED windows on each button can glow in cool blue, orange, or combinations of both, indicating when a controlled device is ON or OFF Auto fallback can dim button LEDs at a set time after the last button press Locator LED can illuminate the keypad, helping a user find it in dim light Clean-lined keypads are wall mounted without external fittings Low-profile design extends only 0.5 in. out from the wall Optional button covers with labels, enabling quick identification of lighting scenes or controlled devices
Saturn Keypads
Table 5.1: Complete Saturn Keypads
Catalog No. Catalog Description $ Price SLC5082NL( ) Saturn Full Plate, 2 button 634.00 SLC5084NL( ) Saturn Full Plate, 4 button 668.00 SLC5086NL( ) Saturn Full Plate, 6 button 700.00 Note: Color codes are: White (WE), Black (BK), Mocha (BR), Cream (CM). The catalog number for a two-button keypad in mocha would be SLC5082NLBR
Table 5.2:
Catalog No. SLC5080LC8 SLC5082FGF SLC5084FGF SLC5086FGF SLC5082F30 SLC5084F30 SLC5086F30 SLC5082F60 SLC5084F60 SLC5086F60 SLC5082F70 SLC5084F70 SLC5086F70
DE-8
Discount Schedule
5-5
C-Bus
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Neo RF Wireless Keypad Saturn RF Wireless Keypad Plug Adaptor Gateway
Neo or Saturn decorator style keypadsmatch your existing decorator switches or C-Bus control system keypads. Gateway to the C-Bus Control SystemConnect your current, or future wired C-Bus control system with your C-Bus RF devices. Use as a stand-alone system, or connect to C-Bus wired systems for controlling third party sub-systems, security access controls, sprinklers and more. 2 wire design eliminates need for a neutral (except 3 and 4-way applications) Compatible with all C-Bus devices via C-Bus network with wireless gateway No PC needed for programmingSimple Learn mode push to program
Switches
C-Bus RF Wireless switches operate all common lighting loads, and work in conjunction with other C-Bus wired and wireless controls. Switches are available in both Neo and Saturn style keypads with either 2 or 4 button configurations.
2 and 4 button options Heavy-duty 8A relay Mounts in standard wall box Neo or Saturn Decorator Styling Multi-function buttonsconfigurable to control any load on the C-Bus network Compatible with a wired C-Bus system using wireless gateway (not included) Compatible with C-Bus wireless RF remote (not included) No neutral required
2 and 4 button options 600W and 1000W models Mounts in standard wall box Neo or Saturn Decorator Styling Multi-function buttonsconfigurable to control any load on the C-Bus network Last level button recall (pre-set) Compatible with a wired C-Bus system using wireless gateway (not included) Compatible with C-Bus wireless RF remote (not included) No neutral required
Scene Controllers
C-Bus RF Wireless scene controllers provide multi-location and scene control from any convenient location. Designed to work in conjunction with other C-Bus wired and wireless controls, these controllers provide the ability to initiate distinct scenes or control individual groups. Scene controllers are available in both Neo and Saturn style keypads in a 4 button configuration.
Mounts in standard wall box Neo or Saturn Decorator Styling Multi-function buttonsconfigurable to control any load on the C-Bus network Last level button recall (pre-set) Compatible with a wired C-Bus system using wireless gateway (not included) Compatible with C-Bus wireless RF remote (not included)
Plug Adaptors
C-Bus RF Plug Adaptors allow the control of appliances and/or lamps using C-Bus RF Wireless Keypads. Plug adaptors come in two different models, a standard switch unit (8A) or 600W dimmer unit. Both models are programmed easily using Learn Mode, or by using the C-Bus Toolkit Software.
Control lamps/appliances using C-Bus RF keypads 600W dimmer model 8A switch model Simple learn mode programming
Gateway
The C-Bus RF Gateway provides a C-Bus protocol communication bridge between a single C-Bus RF wireless system and a single C-Bus wired network. Both the wired and wireless C-Bus network types use the same protocol commands, thus by using the Gateway, a C-Bus RF wireless and wired network can communicate and seamlessly interact with each other. This allows a wireless C-Bus control system third party functionality, with the ability to control audio, blinds, irrigation systems, etc. The RF Gateway can be installed horizontally, by using the adhesive feet (included) or vertically, using the keyhole cutouts on the base of the unit.
Control between wired and wireless C-Bus networks Mount horizontally or vertically Enable third party operability by connecting a wireless network to a wired network Adjustable antenna for clear reception Simple Cat-5 connection to C-Bus wired system
5-6
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
Lighting Control
Class 1250
DLT Keypads
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
Saturn Dynamic Labeling Technology (DLT) Keypads combine a programmable keypad button, and easily customized labels on a backlit LCD screen that eliminates the need for custom labels. By virtue of the variety of button configurations available, one compact DLT keypad can take the place of many single-operation switches, ON/OFF toggles, dimmers, and timers. The five keypad buttons incorporate blue LEDs which complements the keypads sleek lines while showing the status of controlled devices.
Button configurations include multi-point switching and dimming, master ON/OFF switching, and scene settings Keypads have five physical buttonsfour control buttons, and one scroll/page buttoncombined with two screens of labels, for a total of eight control buttons and two scroll/page buttons Scene control includes up to forty addresses per keypad. Larger scenes are possible by sharing memory among multiple keypads. Independent timers available for each button Button LEDs can be used as locator lights in the dark 64 x 128 pixel LCD screen with a white backlight Editable LCD labels, available for each button or control group, can display text, symbols, and graphics. Dynamic graphic displays, such as bar graphs, can be enabled or disabled Bitmaps can be downloaded for each group address or scene Low-profile design, wall mounted without external fittings
Table 5.1:
Saturn Style Keypad
Catalog No. SLC5085DLWE SLC5085DLBK SLC5085DLCM SLC5085DLBR SLC5055DLGB SLC5055DLWE SLC5055DLBK SLC5055DLSG SLC5055DLCM SLC5055DLDS
Table 5.2:
Catalog No. SLC5085DLFCM SLC5085DLFBK SLC5085DLFBR SLC5085DLFWE SLC5055DLFGB SLC5055DLFBR SLC5055DLFCM SLC5055DLFBK SLC5055DLFSG SLC5055DLFDS SLC5055DLFWE
DE-8
Discount Schedule
5-7
C-Bus
New!
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Neo Decorator Keypad Saturn Decorator Keypad Neo Decorator Style Cover Plate 2 Gang Saturn Decorator Style Cover Plate
Button configurations include multi-point switching, dimming, and scene control LED indicator reflects status of each button Built-in infrared receiver to allow operation from C-Bus handheld remote control Distinctive Neo styling designed to match standard Neo keypads and touchscreens Custom color combinations available on request Meets NEMA Standards WD-1, WD-6
Table 5.1:
Catalog No. Description $ Price Neo Decorator 1 button keypad (XX) Designates Color. (order cover plate separately) SLC5051NLM(XX) 1 button decorator keypad 386.00 Neo Decorator 2 button keypad (order cover plate separately) SLC5052NLM(XX) 2 button decorator keypad brushed aluminum 408.00 Neo Decorator 3 button keypad (order cover plate separately) SLC5053NLM(XX) 3 button decorator keypad brushed aluminum 430.00 Neo Decorator 4 button keypad (order cover plate separately) SLC5054NLM(XX) 4 button decorator keypad brushed aluminum 452.00 Neo Decorator Blanking Plate (order cover plate separately) SLC5850BP(XX) Neo blanking plate 14.00 Note: Designate colors (XX), when placing order for Neo style decorator keypads. GB Brushed, WE White, CM Cream, SG Soft Grey, DS Desert Sand, BK Black, BR Brown.
Button configurations include multi-point switching, dimming, and scene control LED indicator reflect status of each button Built-in infrared receiver to allow operation from C-Bus remote controllers Distinctive Saturn styling designed to match standard Saturn keypads and touchscreens Meets NEMA Standards WD-1, WD-6
Table 5.2:
Catalog No. Description Saturn Decorator 1 button keypad (XX) Designates Color. (order cover plate separately) SLC5081NLM(XX) 1 button deco Saturn keypad, White Saturn Decorator 2 button keypad (XX) Designates Color. (order cover plate separately) SLC5082NLM(XX) 2 button deco Saturn keypad, White Saturn Decorator 3 button keypad (XX) Designates Color. (order cover plate separately) SLC5083NLM(XX) 3 button deco Saturn keypad, White Saturn Decorator 4 button keypad (XX) Designates Color. (order cover plate separately) SLC5084NLM(XX) 4 button deco Saturn keypad, White Blanking Plates SLC5880BPPG(XX) Saturn Blanking Plate Note: Designate colors (XX), when placing order for Saturn style decorator keypads. WE White, CM Cream, BK Black, BR Brown.
Sleek, smooth contemporary architectural styling enhances fine decor Screwless design for easy placement Two piece kit allows easy retrofit Meets NEMA Standards WD-1, WD-6
Table 5.3:
Catalog No. Description $ Price Neo Decorator Cover Plate 1 ganga SLC5051GA(XX) 1 gang wallplate 14.00 Neo Decorator Cover Plate 2 ganga SLC5052GA(XX) 2 gang wallplate 18.00 Neo Decorator Cover Plate 3 ganga SLC5053GA(XX) 3 gang wallplate 22.00 Neo Decorator Cover Plate 4 ganga SLC5054GA(XX) 4 gang wallplate 26.00 a Cover plate assembly includes inner and outer surrounds. Wall plate ordering (Order keypads separately). Order numbers for the Neo decorator style wall plates indicate the gang number desired on the wall plate and the color of the wall plate itself. Color codes are: Slate (1), White (2), Cream (3), Soft gray (4), Desert sand (5), Black (6), Brown (7), Brushed aluminum (8), and Gold (9). For example, SLC505(1)GA(51) represents an order fo a Neo decorator style wall plate in one gang configuration, with a Desert sand outer surround and a slate inner surround.
Table 5.4:
Catalog No. Description $ Price Saturn Decorator Cover Plate 1 gangb SLC5081GAPG(XX) 1 gang wallplate 24.00 Saturn Decorator Cover Plate 2 gangb SLC5082GAPG(XX) 2 gang wallplate 28.00 Saturn Decorator Cover Plate 3 gangb SLC5083GAPG(XX) 3 gang wallplate 38.00 Saturn Decorator Cover Plate 4 gangb SLC5084GAPG(XX) 4 gang wallplate 45.00 b To specify color, add corresponding alpha codes. Black = BK, White = WE, Cream = CM, Mocha = BR. Example SLC5081GA(XX) = Saturn Decorator 1 gang, White
5-8
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
Lighting Control
Class 1250
Touch screens
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
C-Bus Touch screens are unified wall-mounted panels for controlling lighting systems and accessories with the touch of a finger. They come in both monochromatic (Mark II) and color screen versions. Compact yet powerful, touch screens offer an attractive alternative to multiple single operation switches, ON/OFF toggles, dimmers, and timers which can clutter up even the nicest wall.
Mark II Monochrome touch screen desktop model
Mark II Monochrome touch screen with Cream Saturn style cover plate
Built-in RJ-45 Ethernet and C-Bus network, RS-232, and USB terminals Touch sensitive 6.4 inch (640 x 480) color LCD panel Control screens support multi-point switching Standard real-time and astronomical clock permits time scheduling of lighting and other tasks Variable dimming fade rates can be configured according to load or lighting zone Locator option can be configured to help users find the screen in dim light Clean-lined low-profile touch screen can be wall-mounted without external fittings Infrared receiver for remote control
Table 5.1:
Catalog No. Catalog Description $ Price 2439.00 2439.00 2439.00 2499.00 2499.00 2499.00 2499.00 2499.00 1920.00 1920.00 8480.00 8480.00 8480.00 8480.00 8480.00 8480.00 8480.00 Mark II Touch Screen SLC5050CTL2WE Mark II w/Neo Style Cover Plate, White SLC5050CTL2GB Mark II w/Neo Style Cover Plate, Brushed Aluminum and Slate SLC5050CTL2BK Mark II w/Neo Style Cover Plate, Black SLC5080CTL2WE Mark II w/Saturn Style Cover Plate, White SLC5080CTL2CM Mark II w/Saturn Style Cover Plate, Cream SLC5080CTL2BR Mark II w/Saturn Style Cover Plate, Mocha SLC5080CTL2BK Mark II w/Saturn Style Cover Plate, Black SLC5000CTL2SS Mark II w/Stainless Steel Cover Plate Mark II Touch Screen Desktop Model SLC5000CTD2WE Mark II desktop touchscreen, White SLC5000CTD2BK Mark II desktop touchscreen, Black Color Touch Screen SLC5080CTC2WE Color touch screen w/Saturn style cover plate, White SLC5080CTC2BK Color touch screen w/Saturn style cover plate, Black SLC5080CTC2BR Color touch screen w/Saturn style cover plate, Mocha SLC5080CTC2CR Color touch screen w/Saturn style cover plate, Cream SLC5050CTCGB Color touch screen w/Neo style cover plate, Brushed Aluminum and Slate SLC5050CTCWE Color touch screen, w/Neo style cover plate, White SLC5050CTCBK Color touch screen, w/Neo style cover plate, Black Accessories Mark II Accessories SLC5000CT2WB Wall box for Mark II touch screen SLC5080CT2FWE Replacement cover plate Saturn style, White SLC5080CT2FCR Replacement cover plate Saturn style, Cream SLC5080CT2FBR Replacement cover plate Saturn style, Mocha SLC5080CT2FBK Replacement cover plate Saturn style, Black SLC5000CT2FSS Replacement cover plate, Stainless Steel SLC5050CT2FWE Replacement cover plate Neo style, White SLC5050CT2FGB Replacement cover plate Neo style, Brushed Aluminum and Slate SLC5050CT2FBK Replacement cover plate Neo style, Black Color Touch Screen Accessories SLC5000CTCRM Plasterboard Bracket for Color Touch Screen SLC5000CTCNA Nail Bracket for Color Touch Screen SLC5000CTCWB Wall box for Color Touch Screen SLC5000CTCPS Power supply for Color Touch Screen SLC5080CTCFBR Replacement cover plate Saturn style, Mocha SLC5080CTCFBK Replacement cover plate Saturn style, Black SLC5080CTCFCM Replacement cover plate Saturn style, Cream SLC5080CTCFWE Replacement cover plate Saturn style, White SLC5080CTCFGB Replacement cover plate Neo style, Brushed Aluminum and Slate SLC5080CTCFWE Replacement cover plate Neo style, White SLC5080CTCFBK Replacement cover plate Neo style, Black 2009 Schneider Electric All Rights Reserved
68.00 203.00 203.00 203.00 203.00 87.00 16.00 16.00 16.00 90.00 60.00 68.00 263.00 356.00 356.00 356.00 356.00 29.00 29.00 29.00
DE-8
Discount Schedule
5-9
Control screens support multi-point switching and dimming, master ON/OFF switching, scheduling, and scenes with multiple loads. Preset scenes and functions automate the task of adjusting lighting levels to different lamps and fixtures. RS-232 port for third party device integration through the built in Logic Engine Standard real-time and astronomical clock permits time scheduling of lighting and other tasks Variable dimming fade rates can be configured according to load or lighting zone Locator option can be configured to help users find the screen in dim light Clean-lined low-profile touch screen can be wall-mounted without external fittings Infrared receiver for remote control Stores up to 250 scenes with 100 group addresses each. Scenes can be triggered directly from the touch screen or any other device on C-Bus
C-Bus
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
5-10
C-Bus
www.schneider-electric.us
Matrix Switcher
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
Matrix Switcher
The C-Bus Audio Matrix Switcher provides a revolutionary means for distributing audio throughout a home. This Matrix Switcher provides up to eight zones of audio output from four source inputs. The C-Bus Matrix Switcher allows you to send streaming audio programs to the audio zones from a variety of sources, including a local area network (LAN), or a USB memory stick (Model: SLC5608842E). In addition, it will also allow connection of a portable music player directly to the Matrix Switchers front audio panel. Audio sources can be selected from the front panel or by any C-Bus input device such as touch screens or keypads. The Matrix Switcher is ideally suited for multi-room audio and structured wiring systems. Keypads and other C-Bus devices connect to the Matrix Switcher via CAT-5 modular jacks. Outputs to remote and desktop amplifiers are made with low voltage wiring. In addition to the six source inputs, two mono broadcast annunciation inputs are provided for connection to intercoms or other systems. Broadcast annunciation input can be given priority over other source inputs and features fully adjustment volume and overstepping mute features.
Suitable for 19 Rack Mount with rack mount ears provided. Each Matrix Switcher can distribute digital audio to up to 8 MRA amplifiers. You can install up to 3 Matrix Switchers on a C-Bus network. The Matrix Switcher can provide power for the attached amplifiers via the Digital Audio cables. You can connect an external power supply to an amplifier to increase its audio power output. The choice of the audio program for an amplifier can be made at the Matrix Switcher or in the audio zone. You can use C-Bus input devices to choose the source and to adjust volume, tone and muting. The Dual AM/FM tuners inside the Matrix Switcher can distribute preset station choices to any of the audio zones. Distributes streaming audio from several sources using the C-Bus Ripple software application running on a networked PC. You can connect up to 4 stereo analogue line-level inputs to the Matrix Switcher. If you need to add another source input, you can install an MRA Distribution Unit and power supply. Compatible with C-Bus devices.
Remote Amplifiers
C-Bus Multi Room Amplifiers provide efficient, high fidelity audio to individual rooms. Available in either desktop or remote mount versions, these amplifiers are specifically designed to operate on the C-Bus network as an extension of a lighting control system, without third party gateways or custom integration. This means the ability to control amplifiers with the same keypad or touch screen used to control lighting levels. When combined with the C-Bus Matrix Switcher, these amplifiers deliver excellent stereo sound. Connections are provided for up to two sets of 8 ohm speakers. Both desktop and remote amplifiers provide a local input connection for attaching to CD or mp3 players, etc. In addition, the desktop amplifier will accept remote commands via its infrared receiver. Infrared remote included.
Desktop Amplifier
Remote Amplifier
10 Watt digital efficient stereo amplifier, 25 Watts when connected to local power supply (optional) Super quiet design On board 8 ohm loudspeaker connections Local source input - RCA jack C-Bus connection (connects with CAT-5 cable) Volume control (desktop model) On-board IR receiver (desktop model) Stereo headphone connection (desktop model) Infrared remote included (desktop model only)
Distributes a single stereo audio source to C-Bus Audio Amplifiers via a digitized signal over Cat-5 cable Does not require any C-Bus programming (hardware only) One stereo analog audio source input (2 X RCA) One digital audio output Output can be looped between C-Bus Audio Amplifiers IR emitter port
Table 5.1:
Catalog No. SLC5608842 SLC5608842E SLC560125D SLC560125R SLC560011 SLC5600P24500S Accessories SLC5600P243750T SLC560125MB
445.93 42.24
DE-8
Discount Schedule
5-11
C-Bus
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Indoor Ceiling Mount Speakers Indoor Wall Mount Speakers Indoor/Outdoor Speakers
Audio Speakers
C-Bus Audio Speakers are available as indoor or outdoor models and are designed to be used with home theater, multi-room, and outdoor audio applications. The indoor speakers come in wall or ceiling mount versions that are installed with the front of the speaker flush with the mounting surface. The indoor/outdoor speakers are available in black or white and can be placed on a shelf or hung on a surface by using the included bracket.
Flush-mount, shelf-mount, and surface-mount models Indoor and outdoor models High-impact plastic components and powder coated metal grills produce a long-lasting unit suitable for indoor and outdoor use 8 ohm impedance Available with Kevlar (indoor units only) or polypropylene drivers (indoor and outdoor units) for high-quality sound in all applications All models are off the floor, saving floor space Indoor/Outdoor Speakers have a pre-installed, removable mounting bracket Indoor/Outdoor Speakers can be placed on a shelf or hung from a surface by their bracket (included) Tracing/painting template included
Table 5.1:
Catalog No. SLC5600IWP SLC5600IWK SLC5600ICP SLC5600ICK SLC5600ODPBK SLC5600ODPWE
5-12
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
Thermostats
Class 1250
C-Bus Thermostats are used to regulate the air temperature of zones by controlling heating-ventilation-air conditioning (HVAC) equipment. The air temperature is monitored by the units temperature sensor or optionally via an external C-Bus temperature sensor. C-Bus single and programmable 4 Zone Thermostats may operate as stand alone devices, or be controlled via other C-Bus devices such as wall switches or touch screens. Programmable 4 Zone Thermostats can schedule up to four set points during a day, and unique schedules can be programmed for each day of the week. Both models include setback mode, (saves power by using a wider acceptable temperature range within which heating or cooling is not performed) and temperature guard, (ensures the temperature is maintained within a specified temperature range).
4 Zone Thermostat
Easy to read, large LCD display Control by keypads and other devices on the C-Bus network Available in black, white and stainless steel fascias Setback mode Temperature guard mode Internal Timer Daily schedule set points (4 Zone model) Display temperature in Celsius or Fahrenheit RWG interface (relay models only) Easily configured by using the Clipsal Toolkit software program
Table 5.1:
Catalog No. SLC5070THBWE SLC5070THPWE SLC5070THBBK SLC5070THPBK SLC5070THBSS SLC5070THPSS SLC5070THBRWE SLC5070THPRWE SLC5070THBRBK SLC5070THPRBK SLC5070THBRSS SLC5070THPRSS SLC5031RDTSL
DE-8
Discount Schedule
5-13
C-Bus
Light Level Sensor
Sensors
Class 1250
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Light Level Sensor 360o Indoor PIR Sensor Outdoor PIR Sensor 90o Indoor PIR Sensor 360o PIR Multi Sensor
The C-Bus Light-Level Sensor measures ambient light levels and automatically issues ON, OFF, or ramp commands over a C-Bus network. The light-level sensor can control relays, dimmers, or remotely operated circuit breakers, changing their status according to pre-set ambient lighting targets. The C-Bus light-level sensor has a dynamic range between 5-150 foot candles, and compensates for noise and rapid light intensity fluctuations.
Outdoor use, wall- and ceiling-mounted low-profile unit Can maintain a constant illumination level of 5-150 footcandles Adjustable lumin setpoint Control of up two C-Bus group addresses Sensors receive data and power over a single C-Bus twisted-pair cable, so they do not require power packs or line-voltage connections 180 field of view
Table 5.1:
Occupancy Sensors
C-Bus occupancy sensors are available for both indoor and outdoor applications. All C-Bus sensors incorporate reliable passive infrared detection (PIR) circuits for occupancy detection along with integral light level sensors to prevent switching of lights if sufficient ambient light is present. Sensors feature programmable adjustments for sensitivity and time delay, walk test LED for commissioning and optical bandpass filtering with dual element detectors to minimize false triggering.
90 Indoor sensors are intended for wall or ceiling mounting. These sensors have a continuous detection field of 400 square feet and a 90 field of view. 360 Indoor sensors are intended for flush mounting in drop ceilings. They have a minor motion detection field of 800 square feet making them ideal for use in offices, copier rooms, closets, and restrooms where it can be mounted in the center of the detection area. 360 Multi-Sensors combine a passive infrared receiver (PIR) for occupancy sensing, a light-level sensor, and an infrared remote receiver into a small, highly versatile unit. The multi-sensors 2.8 inch face diameter makes it unobtrusive and ideally suited for flush mounting on the ceiling with effective IR coverage up to 800 square feet. The built-in IR receiver accepts commands from an optional handheld remote controller, making the sensor ideal for classrooms and conference room areas. Outdoor PIR Motion Sensor combines reliable thermal-radiation-based control of lighting with rugged construction suitable for outdoor requirements. The units advanced circuits and flat multisegmented lens provide coverage of up to 3000 square feet in a 110 field of view.
Table 5.2:
5-14
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
Input Units
Class 1250
C-Bus Four-Channel Auxiliary Input Units increase the versatility of the C-Bus network by facilitating remote access with any dry-contact switch mechanism. DIN-rail mounted for quick installation, the auxiliary unit can be configured with standard C-Bus control functions such as remote scene triggering, ON/OFF, toggle, dimmer, or timer.
Provides four isolated inputs for external voltage-free mechanical switches Control options include remote scene triggering, ON/OFF, toggle, dimmer, or timer operations LEDs indicate operational status of each channel Standard built-in C-Bus network connectors: (2) RJ-45 Non-volatile memory stores operating status for recovery from a power outage DIN style construction 4M wide: 3.4(L) x 2.8(W) x 2.6(H) Compatible with all Clipsal devices and the Square D Powerlink NF3000G3C controller
Four-Channel General Input Units measure TTL digital and real-world analog quantities and generate messages about the measurements to the C-Bus network. By acting as an interface with various external sensors, the general input unit enables integration of the C-Bus network with a variety of system types, such as those for HVAC and for power monitoring. Configuration options include selectable input types, eight adjustable decision thresholds per channel, definable actions, selectable filtering, broadcast rates, and a separate hysteresis value per channel.
Measures TTL digital quantities including voltage, current, or resistance from external sensors such as light level, pressure, and temperature Four channels of input, each with an adjustable hysteresis value, eight decision thresholds, and a software-selectable input value transformation in the form y =ax +b Input channels are compatible with a range of third-party sensors Control functions include load switching, dimming, trigger applications, enable control applications, and measurement applications Includes 120V/24Vdc power pack Dimensions: 5.67 in. (144mm) wide x 2.60 in. (66mm) deep x 3.35 in. (85mm) tall Compatible with all Clipsal devices and the Square D Powerlink NF3000G3C controller
Bus Couplers
Bus Couplers provide an interface between dry-contact mechanical switches and the C-Bus network. Available in two-and four-channel models, the bus coupler is small enough to be used in restricted spaces such as wall boxes with existing switches. Configuration options include standard control functions such as ON/OFF, toggle, dimmers, and timers.
CLIPSAL
5104BCL Bus Coupler 1 2 3 4
Provides two or four non-isolated inputs for external voltage-free mechanical switches. Two-channel units feature independent remote LED outputs Two-way removable terminal block for the C-Bus connection Receives data and power over a network, so it does not require power packs or line voltage connections Scene capabilities 2.2(L) x 1.9(W) x 0.7(H) Compatible with all Clipsal devices and the Square D Powerlink NF3000G3C controller
Table 5.1:
Input Units
Catalog Description 4 Channel auxiliary input unit 4 Channel general input unit 2 Channel bus coupler 4 Channel bus coupler $ Price 544.00 1194.00 212.00 243.00
DE-8
Discount Schedule
5-15
C-Bus
Relays
Relay Units
Class 1250
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Changeover Relay 4-Channel 10A Relay 4-Channel 20A Relay
C-Bus Relay Units are intended for switching resistive, inductive, fluorescent and incandescent low-voltage loads. Relay units are designed to be mounted in suitable DIN style enclosures. Relay units feature:
Local toggle buttons to allow individual channels to be toggled Remote ON and OFF facilities permitting all channels to be turned ON or OFF without C-Bus Network communications Two (2) Convenient built-in C-Bus network connectors (RJ-45) LED Indicators to show the status of the network and the unit Units available both with and without a 200ma power supply on-board. Compatible with all Clipsal devices and the Square D Powerlink NF3000G3C controller
Changeover Relay
C-Bus 2A Changeover Relays are designed to operate three-speed motors and two-way motor control devices. Some of their most common applications include operating motorized blinds, shutters, curtains and skylights (open/closed) where they provide a much simpler alternative to traditional and obtrusive relay interlocking systems.
Four (4) isolated independently operating relay channels 120Vac and 277Vac units 2A motor rating Dimensions: 5.67 in. (144mm) wide x 2.60 in. (66mm) deep x 3.35 in. (85mm) tall
Table 5.1:
Changeover Relays
Catalog Description 4 Channel Changeover Relay, 125V, with power supply 4 Channel Changeover Relay, 125V, without power supply 4 Channel Changeover Relay, 277V, with power supply 4 Channel Changeover Relay, 277V, without power supply $ Price 1100.00 1010.00 1100.00 1010.00
10 Amp Relay
C-Bus 10A Relays feature a zero crossing magnetically latching relay designed for switching the harsh electrical loads associated with todays high efficiency lighting systems.
Four (4) or twelve (12) independently operating voltage free relay contacts 120Vac and 277Vac units 10A rating Dimensions: 5.67 in. (144mm) wide x 2.60 in. (66mm) deep x 3.35 in. (85mm) tall
Table 5.2:
10 Amp Relay
Catalog Description 12 Channel Relay, 120V, 10A with power supply 12 Channel Relay, 120V, 10A without power supply 4 Channel Relay, 120V,10A with power supply 4 Channel Relay, 120V, 10A without power supply 12 Channel Relay, 277V, 10A with power supply 12 Channel Relay, 277V, 10A without power supply 4 Channel Relay, 277V,10A with power supply 4 Channel Relay, 277V, 10A without power supply $ Price 2168.00 1973.00 1043.00 843.00 2168.00 1973.00 1043.00 843.00
Catalog No. SLC5512TRVF SLC5512TRVFP SLC5504TRVF SLC5504TRVFP SLC5512HRVF SLC5512HRVFP SLC5504HRVF SLC5504HRVFP
20 Amp Relay
C-Bus 20A Relays feature a zero crossing magnetically latching relay designed for switching the harsh electrical loads associated with todays high efficiency lighting systems.
Four (4) independently operating voltage free relay contacts 120Vac and 277Vac units 20A rating Dimensions: 8.46 in. (215mm) wide x 2.60 in. (66mm) deep x 3.35 in. (85mm) tall
Table 5.3:
20 Amp Relay
Catalog Description 4 Channel Relay, 120V, 20A with power supply 4 Channel Relay, 120V, 20A without power supply 4 Channel Relay, 277V, 20A with power supply 4 Channel Relay, 277V, 20A without power supply $ Price 1320.00 1142.00 1320.00 1142.00
New!
8 channels of 2A switched loads @ 30Vac/dc 8 channels are all isolated change over relays Control of 3rd party products
Table 5.4:
5-16
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
Dimmer Units
Class 1250
C-Bus Phase Angle Dimmers are intended for controlling incandescent and compatible lowvoltage and florescent lighting. Each of the units channels can independently control loads to create dynamic lighting scenes. These dimmer units automatically compensate for voltage and frequency fluctuations and employ advanced phase-control techniques to reduce flicker and increase lamp life.
Four (4) independent channels supporting up to 4A continuous load per channel, eight (8) independent channels supporting up to 2A continuous load per channel Units available both with and without a 200mA power supply on-board. 120Vac Dimensions: 8.46 in. (215mm) wide x 2.60 in. (66mm) deep x 3.35 in. (85mm) tall
Professional Dimmer
C-Bus Professional Dimmers can control incandescent and compatible low-voltage and florescent lighting. These dimmers are ideal for larger heavily loaded circuits. Each channel provides independent dimming and incorporates thermal overload and over-current protection. These dimmer units automatically compensate for voltage and frequency fluctuations and employ advanced phase-control techniques to reduce flicker and increase lamp life. An optional terminal box is available for conduit connections. Configuration options include network monitoring of the channel load and network voltages, adjustable delays for dimming levels, and master override.
Professional Dimmer
Specialized dimming modessoft turn on/off and linear brightness control Built-in power supply sources 60 mA to the C-Bus network Individual channels can be turned On/Off at the unit or via C-Bus commands LEDs indicate the status of the network at the unit and the status of the units load and power Optional terminal box for connecting conduit 120Vac Dimensions: 7.5 in. (190mm) wide x 3.0 in. (75mm) deep x 7.7 in. (195mm) tall
Table 5.1:
C-Bus Dimmers
Catalog Description 4 x 4A dimmer, incan/mag,125V, 4A, with power supply 4 x 4A dimmer, incan/mag,125V, 4A, without power supply 8 x 2A dimmer, incan/mag,125V, 2A, with power supply 8 x 2A dimmer, incan/mag,125V, 2A, without power supply 4 x 5A dimmer, incan/mag,125V, with power supply 2 x 10A dimmer, incan/mag,125V, with power supply 1 x 20A dimmer, incan/mag,125V, with power supply Termination box for SLCLU510X Series dimmer units $ Price 1024.00 800.00 1024.00 800.00 1926.00 1926.00 1926.00 78.00
Catalog No. SLC5504TD4A SLC5504TD4AP SLC5508TD2A SLC5508TD2AP SLC5104TD5 SLC5102TD10 SLC5101TD20 SLCU5100TB
Analog Output Unit
Produces four independently controllable channels of 0-10Vdc for controlling dimmable lighting ballasts or other loads Individual channels can be turned ON/OFF at unit, via C-Bus commands, and through a remote override option 120V or 277Vac models available DIN style construction 4M wide: 3.4(L) x 2.8(W) x 2.6(H)
Table 5.2:
Catalog No. SLCLE5504TAMP SLCLE5504HAMP Catalog Description 4 Channel 0 - 10V Output, 120V 4 Channel 0 - 10V Output, 277V $ Price 624.00 624.00
DE-8
Discount Schedule
5-17
C-Bus
System Units
Class 1250
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Network Bridge Power Supply PC Interface DALI Gateway
Network Bridge
The C-Bus Network Bridge provides a communication channel between C-Bus units on separate networks, expanding the total number of units that can be configured, controlled, and monitored.
Increases transmission distances by acting as a repeater station for data transmission Expands the total number of Clipsal devices that can operate on the system by isolating devices to individual networks Indicates each networks status level Uses built-in connectors to connect to a C-Bus network Compatible with Powerlink G3 3000C controller and all Clipsal components, including keypads, sensors, and dimmers DIN style construction 4M wide: 3.4(L) x 2.8(W) x 2.6(H)
Power Supply
The C-Bus Power Supply is specifically designed to operate with the C-Bus network as a power source for passive C-Bus devices. Up to five power supplies can be connected to a single C-Bus network.
Available in 120 and 277Vac models Regulating power supply compensates for line voltage and frequency variations, so there is constant output Sources up to 350 mA to the C-Bus network UL listed to operate in parallel with other Clipsal power supplies, up to five on a single C-Bus network Incorporates short circuit and reverse polarity protection DIN style construction 4M wide: 3.4(L) x 2.8(W) x 2.6(H)
PC Interface
The C-Bus PC Interface (PCI) expands options for configuring, controlling, and monitoring C-Bus networks by providing an interface between the network and a personal computer (PC). The C-Bus PCI module easily mounts to a DIN rail and connects to the C-Bus network. Power to the unit is provided through the C-Bus network. Serial
Unit/Comms LED shows the status of the units power and of any data transmissions Three RS-232 serial connectors for connecting to a PC or to external devices: (1) 9-pin D-type serial connector (female) and (2) 8pin RJ-45 connectors Two C-Bus network connector ports: RJ-45 sockets Data cable for connecting PCI and personal computer, including DB9 connectors Unit/Comms LED shows the status of the units power and of any data transmissions Two C-Bus network connector ports: RJ-45 sockets USB PC connection Data cable for connecting PCI and personal computer
USB
Connects directly to C-Bus network Powered from the C-Bus network USB port for connection to personal computer (2) RS232 ports for third party device control Real time, astronomical and C-Bus system clock included with 24 hour internal capacitor backup and external 12 Vdc battery terminals
Programming capabilities including: i.e. Conditional logic (if, then, and, or, not, etc.), Flow Control (for, repeat, while), Variables (integer, real, Boolean, character, string), Control and monitoring of group addresses, Control and monitoring of scenes.
DALI Gateway
The C-Bus Digital Addressable Lighting Interface (DALI) Gateway provides an isolated two-way communications path between a C-Bus network and two DALI networks, making it possible to use C-Bus devices to control DALI ballasts.
Provides two-way communications between C-Bus and DALI networks, routing selected messages from one to the other Unit is transparent and invisible to DALI ballasts Receives data and power over the network, so the unit does not require power packs or line-voltage connections DIN style construction 4M wide: 3.4(L) x 2.8(W) x 2.6(H)
5-18
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
System Units
Class 1250
The C-Bus Ethernet Network Interface unit is a C-Bus system device designed to provide an isolated communications path between an Ethernet 10Base-T Network and a C-Bus Network. This allows high-speed control and monitoring of a C-Bus installation via the TCP/IP protocols used in computer networks and by the Internet. System integrators and installers will also benefit from having remote access to the system. With the C-Bus Ethernet Network Interface unit, access to a single or multiple networks can be as close as the nearest Ethernet connection.
Ethernet Network Interface
Remote access to Clipsal systems Bridge multiple C-Bus networks together over LAN or WAN Fully supports all Clipsal commands Small size, mounts in standard DIN enclosure (4M wide) Includes 12 Vdc power supply
Remote location override Voice prompts and confirmation Password protected 32 supported devices Automatic dial out on present conditions Local or remote site access to C-Bus system Audio Out
Network Analyzer
The C-Bus Analyzer is a C-Bus device designed to help an installer quickly analyze, detect, and troubleshoot potential problems on a C-Bus network. The device analyzes the network parameters and prompts the user for appropriate actions via its front LED (Light Emitting Diode) indicators. Table 5.1: System Units
Catalog Description Network bridge 120V Power supply, 350mA 277V Power supply, 350mA RS-232 PC Interface USB PC Interface 2 Channel DALI Gateway Pascal Automation Controller Ethernet Network Interface Telephone Interface Unit Bar Code Reader C-Bus Network Analyzer $ Price 663.00 500.00 500.00 488.00 488.00 1014.00 586.00 664.00 898.00 604.00 328.00
Catalog No. SLC5500NB SLC5500TPS SLC5500HPS SLC5500PC SLC5500PCU SLC5502DAL SLC5500PACA SLC5500CN SLC5100TUS Accessories SLC5100BCS SLC5100NA
DE-8
Discount Schedule
5-19
C-Bus
8M Enclosure
Enclosures
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS 8M Enclosure 12M Enclosure
The 8M enclosure is specifically designed for distributed applications. Suitable for surface mounting, the 8M enclosure consists of a box with a cover and a DIN rail for mounting one 8M or two 4M C-Bus units. The enclosure also has provisions for mounting neutral and ground bars.
Surface-mount NEMA 1 enclosure Welded sheet steel with knockouts Gray baked enamel, electrodeposited over cleaned, phosphatized steel Triple-lead cover screws for fast installation of cover DIN rail, suitable for mounting one 8M or two 4M C-Bus DIN modules
12M Enclosure
The 12M enclosure is specifically designed for distributed applications that require physical proximity between DIN units and keypads, sensors or controlled loads. Suitable for surface mounting, the 12M enclosure consists of a box with a cover and a DIN rail for mounting three 4M C-Bus units, one 8M unit plus one 4M unit or one 12M unit. The enclosure also has factory mounted neutral and ground bars.
Surface-mount NEMA 1 enclosure Welded sheet steel with knockouts Gray baked enamel, electrodeposited over cleaned, phosphatized steel Triple-lead cover screws for fast installation of cover DIN rail, suitable for mounting one 12M or three 4M C-Bus DIN modules
24M Enclosure
The 24M enclosure is specifically designed for distributed applications that require physical proximity between DIN units and keypads, sensors or controlled loads. Suitable for surface mounting, the 24M enclosure consists of a box with a cover and two rows for mounting C-Bus DIN-mounted C-Bus units. Each row can hold one 12M unit, one 8M unit plus one 4M unit, or three 4M untis. The enclosure also has provisions for additional neutral and ground bars.
New!
Surface-mount NEMA 1 enclosure Welded sheet steel with knockouts Gray baked enamel, electrodeposited over cleaned, phosphatized steel Triple-lead cover screws for fast installation of cover DIN rail, suitable for mounting Clipsal DIN-mounted C-Bus units. Each row can hold one 12M unit, one 8M unit plus one 4M unit, or three 4M units
24M Enclosure
NEMA 1 enclosure suitable for flush or surface mounting Welded sheet steel with knockouts Gray baked enamel paint, electrodeposited over cleaned, phosphatized steel Triple-lead cover screws for fast installation of cover 3 DIN mounting rails, each accommodating up to one 12M unit, one 8M unit with one 4M unit, or three 4M units Complete with barriers for separation of Class 2 circuits from line voltage (36M only) The 36MS offers a reduced footprint than the 36M
60M Enclosure
The 60M enclosure provides a means for housing DIN style relays and dimmers. Suitable for flush or surface mounting, the enclosure consists of a mounting pan assembly, and a cover assembly. The box is to be ordered separately, allowing for its installation with the rough-in of field wiring. Enclosures feature:
NEMA 1 enclosure suitable for flush or surface mounting Welded sheet steel with knockouts Gray baked enamel paint, electrodeposited over cleaned, phosphatized steel Triple-lead cover screws for fast installation of cover 5 DIN mounting rails, each accommodating up to one 12M unit, one 8M unit with one 4M unit, or three 4M units Complete with barriers for separation of Class 2 circuits from line voltage
Table 5.1:
Catalog No. 8M Enclosure SLC8M 12M Enclosure SLC12MSG 24M Enclosure SLC24MSG 36MS Enclosure SLC36SC SLC36MSFG SLC36MSFW SLC36MSSG 36M Enclosure SLC36C SLC36MFG SLC36MFW SLC36MSG 60M Enclosure SLC36C SLC60MFG SLC60MFW SLC60MSG Accessories PK7GTA PKGTAB SLC4CSF8
36M Enclosure
5-20
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
System Devices
Area Lighting Panels
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
C-Bus Area lighting Panels are ideally suited to meet lighting control energy code requirements in classrooms, offices and other small spaces. Area Lighting Panels are designed to be used with C-Bus input units, including: keypads, sensors (occupancy and light level detection) and touch screens. A simple CAT-5 cable is all that is required for connecting of these devices. C-Bus Area Lighting Panels provide on/off switching, stepped dimming or continuous dimming. All relays feature rugged 20 A rated contacts for switching electronic ballast loads. Models with continuous dimming capabilities are available with phase angle or 010V control. C-Bus Area Lighting Panels can operate independently or as part of an entire facility wide lighting control system. Enclosures can easily be mounted in electrical closets or in ceiling spaces. They include all necessary connections and are UL Listed. Area Lighting Panels can also be used in conjunction with Powerlink panels.
Relay models: Four (4) or Eight (8) channel relay outputs, rated 20 A Phase Angle Dimmer Model: Four (4) channels of 4 A outputs for incandescent lighting loads. 010V outputs available for control of 010V dimmable fluorescent ballast Integral neutral and ground bar terminal strips Meets NEC 300.22 requirements to be installed above ceilings and other spaces that handle environmental air Bypass mode to facilitate quick start up Meets NEC Article 409 UL Listed 508 A
Table 5.1:
Catalog No.
4 Channel 20 A Relay Models SLCZ042000T 4 Channel 20 A Relay @ 120 V with power supplya SLCZ042000H 4 Channel 20 A Relay @ 277 V with power supplya SLCZ042000TP 4 Channel 20 A Relay @ 120 V without power supply SLCZ042000HP 4 Channel 20 A Relay @ 277 V without power supply 8 Channel 20 A Relay Models SLCZ082000T 8 Channel 20 A Relay @ 120 V with power supplya SLCZ082000H 8 Channel 20 A Relay @ 277 V with power supplya SLCZ082000TP 8 Channel 20 A Relay @ 120 V without power supply SLCZ082000HP 8 Channel 20 A Relay @ 277 V without power supply 4 Channel 20 A Relay Models with 0-10 V Output Units SLCZ04204AT 4 Channel 20 A Relay @ 120 V with power supply and 4 Channel 0-10 V Output Unita SLCZ04204AH 4 Channel 20 A Relay @ 277 V with power supply and 4 Channel 0-10 V Output Unita SLCZ04204ATP 4 Channel 20 A Relay @ 120 V without power supply and 4 Channel 0-10 V Output Unit SLCZ04204AHP 4 Channel 20 A Relay @ 277 V without power supply and 4 Channel 0-10 V Output Unit 4 Channel 20 A Phase Angle Dimmer Models SLCZ00004DT 4 Channel 20 A Phase Angle Dimmer @ 120 V with C-Bus power supplya SLCZ00004DTP 4 Channel 20 A Phase Angle Dimmer @ 120 V without C-Bus power supply 4 Channel 20 A Relay Models with Phase Angle Dimmer Units SLCZ04204DT 4 Channel 20 A Relay @ 120 V with C-Bus power supply and 4 Ch. Phase Angle Dimmer Unita SLCZ04204DTP 4 Channel 20 A Relay @ 120 V without C-Bus power supply and 4 Ch. Phase Angle Dimmer Unit a For stand-alone applications order unit with power supply.
DE-8
Discount Schedule
5-21
C-Bus
Software Packages
Class 1250
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Schedule Plus Software Screen Captures HomeGate Software Screen Captures
5-22
DE-8
Discount Schedule
C-Bus
www.schneider-electric.us
RF Remote Control
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
C-Bus Wireless RF Remote Controls provide control of a C-Bus Wireless RF Control Systems keypads and/or plug adapter units. Up to ten separate keypad or plug adapter unit buttons can be controlled by this remote control. The buttons can be on various units on different wireless networks. A single button on a keypad or plug adaptor unit can be controlled by up to two RF remote controls.
Compatible with all C-Bus RF keypads 10 separate programmable buttons All OFF button Dim up/down button LCD screen w/indicator and learn mode indicator Wall-mountable holder (included) Two AAA batteries (included)
Table 5.1:
Catalog Number Catalog Description $ Price Neo Style RF Wireless Switchesc SLC5852R8FUM(xx)a Neo 8A Switch 2 Button Module 400.00 SLC5854R8FUM(xx)a Neo 8A Switch 4 Button Module 416.00 Neo Style RF Wireless Dimmersc SLC5852D4LUM(xx)a Neo 600W Dimmer 2 Button Module 386.00 SLC5854D4LUM(xx)a Neo 600W Dimmer 4 Button Module 408.00 SLC5852D8LUM(xx)a Neo 1000W Dimmer 2 Button Module 415.00 SLC5854D8LUM(xx)a Neo 1000W Dimmer 4 Button Module 428.00 Neo Style RF Wireless Scene Controllersc SLC5854NLM(xx)a Neo Scene Controller 4 Button Module 392.00 Saturn Style RF Wireless Switchesc SLC5882R8FUM(xx)b Saturn 8A Switch 2 Button Module 416.00 SLC5884R8FUM(xx)b Saturn 8A Switch 4 Button Module 430.00 Saturn Style RF Wireless Dimmersc SLC5882D4LUM(xx)b Saturn 600W Dimmer 2 Button Module 398.00 SLC5884D4LUM(xx)b Saturn 600W Dimmer 4 Button Module 425.00 SLC5882D8LUM(xx)b Saturn 1000W Dimmer 2 Button Module 430.00 SLC5884D8LUM(xx)b Saturn 1000W Dimmer 4 Button Module 455.00 Saturn Style RF Wireless Scene Controllersc SLC5884NLM(xx)b Saturn Scene Controller 4 Button Module 392.00 Plug Adaptors SLC5812R8FUM Relay Plug Adaptor 288.00 SLC5812D5L1UD Dimmer Plug Adaptor 288.00 Wireless Gateway SLC5800WCGD Wireless Gateway 406.00 Wireless RF Remote SLC5888TXBD RF Remote 375.00 a Keypad ordering: Neo Style Order numbers for the Neo RF decorator style keypads indicate the color of the keypad itself. (xx) Color codes are: Slate (GB), White (WE), Cream (CM), Soft gray (SG), Desert sand (DS), Black (BK), and Brown (BR). b Keypad ordering: Saturn Style Order numbers for the Saturn RF decorator style keypads indicate the color of the keypad itself. (xx) Color codes are: White (WE), Cream (CM), Black (BK), and Mocha (BR). c Wallplates sold seperately.
Remote Control
DE-8
Discount Schedule
5-23
Occupancy Sensors
Basic Wall Switch Occupancy Sensors
Wall Switch Occupancy Sensors are ideally used in commercial buildings to save energy that would otherwise be wasted to light unoccupied rooms or spaces. These Wall Switch Occupancy Sensors employ the latest in passive infrared (PIR) sensing technology to accurately sense when a room or space is occupied, then turn lights on. When the room is unoccupied, the sensor turns lights off after a time delay of up to 30 minutes as determined by the user. Auto-ON and Manual-ON models available with decorator wall plate in white or ivory. Simply mount the sensor in place of existing single gang switch no neutral connection required. Special multi-segmented lens creates a coverage pattern that accurately detects major motion in rooms up to 1000 sq. ft.
Lighting Control
Class 1200
www.schneider-electric.us
Furnished with cover plate Manual On/Manual Off or Automatic Off operation No neutral or minimum load required Rated for both 120 V incandescent and fluorescent lighting Title 24 2005 Residential Lighting requirements, Sec. 150(k) No override on Manual-on only (no auto-on mode) 30 minute time delay
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Wall Switch Occupancy Sensor Commercial Grade Wall Switch Blank Cover Plate with decorator style opening Toggle Cover Plate with decorator style opening
Table 5.1:
Catalog No. Catalog Description $ Price Basic Wall Switch Occupancy Sensors Auto-ON/Auto-OFF SLSPWS1277AW White Wall Switch Occupancy Sensor SLSPWS1277AI Ivory Wall Switch Occupancy Sensor Manual-ON/Auto-OFF SLSPWS1277MW White Wall Switch Occupancy Sensor SLSPWS1277MI Ivory Wall Switch Occupancy Sensor Residential Vacancy Sensor SLSPWS120VI Wall switch vacancy sensor, ivory SLSPWS120VW Wall switch vacancy sensor, white Commercial Grade Wall Switch Occupancy Sensors Single Circuit PIR SLSPWS1277UW White SLSPWS1277UI Ivory SLSPWS1277UG Gray SLSPWS1277UL Light Almond SLSPWS1277UB Black Dual Circuit PIR SLSPWD1277UW White SLSPWD1277UI Ivory SLSPWD1277UG Gray SLSPWD1277UL Light Almond SLSPWD1277UB Black Single Circuit Ultrasonic SLSUWS1277UW White SLSUWS1277UI Ivory SLSUWS1277UG Gray SLSUWS1277UL Light Almond SLSUWS1277UB Black Dual Circuit Ultrasonic SLSUWD1277UW White SLSUWD1277UI Ivory SLSUWD1277UG Gray SLSUWD1277UL Light Almond SLSUWD1277UB Black Single Circuit Dual Technology SLSDWS1277UW White SLSDWS1277UI Ivory SLSDWS1277UG Gray SLSDWS1277UL Light Almond SLSDWS1277UB Black Dual Circuit Dual Technology SLSDWD1277UW White SLSDWD1277UI Ivory SLSDWD1277UG Gray SLSDWD1277UL Light Almond SLSDWD1277UB Black Blank Cover Plates SLSWP2DBW White SLSWP2DBI Ivory SLSWP2DBG Gray SLSWP2DBL Light Almond SLSWP2DBB Black Toggle Cover Plates SLSWP2DTW White SLSWP2DTI Ivory SLSWP2DTG Gray SLSWP2DTL Light Almond SLSWP2DTB Black Buttonless Cover Plates SLSBCW Buttonless Adjustment Access Covers, White SLSBCI Buttonless Adjustment Access Covers, Ivory SLSBCG Buttonless Adjustment Access Covers, Gray SLSBCL Buttonless Adjustment Access Covers, Light Almond SLSBCB Buttonless Adjustment Access Covers, Black 81.00 81.00 62.00 62.00 42.00 42.00
Input: 120/277Vac 60 Hz Output: 1000W Max. Load @ 120V (1000VA@120V 1800VA@277V) 1/4 HP Max. Motor Load UL and cUL Listed For use with electronic and magnetic ballasts CEC Title 24 Certified
90.00 90.00 90.00 90.00 90.00 117.00 117.00 117.00 117.00 117.00 142.00 142.00 142.00 142.00 142.00 165.00 165.00 165.00 165.00 165.00 187.00 187.00 187.00 187.00 187.00 210.00 210.00 210.00 210.00 210.00 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 15.00 15.00 15.00 15.00 15.00
Available in white, ivory, gray, light almond and black with matching cover plate (included) Color matching multi-segmented lens Audible alert Selectable auto-on and manual-on modes Red LED motion indicator For use with electronic and magnetic ballasts 1000VA@120V, 1800VA@277V User adjustable light level, time delay, and sensitivity 30 second grace period in the manual-on mode
No user time delay and sensitivity adjustments necessary Available in white or ivory
5-24
Occupancy Sensors
www.schneider-electric.us
Lighting Control
Class 1200
Wall Mount Occupancy Sensors from Schneider Electric accurately detect occupancy and automatically switch lighting on and off as needed. These sensors are wall or ceiling mounted for superior motion detection. Sensors employ Passive Infrared (PIR) and Ultrasonic technology. Dual Technology model features combined PIR and Ultrasonic detection for the ultimate performance. The PIR Occupancy Sensor has 3 interchangeable lenses for custom coverage patterns. Wide Angle, Long Range and High Bay. Wall mount sensors also incorporate an integral light level sensor, and features an isolated relay for use with building automation, security and HVAC systems.
New!
Adjustable Sensitivity Adjustable time delay UL and cUL Listed CEC Title 24 Certified FCC Part 15, Class B ASHRAE/IES 90.1
Table 5.1:
Catalog No. SLSWPS1500 SLSWUS1500 SLSWDS1500
Ceiling Mount Occupancy Sensors are ideal for offices, conference rooms, class rooms and other shared areas to automatically turn lights on and off based on occupancy. Sensors employ Passive Infrared (PIR) and Ultrasonic technology. Dual Technology model features combined PIR and Ultrasonic detection for the ultimate performance. Requires power pack. Set of normally closed and normally opened auxiliary contacts for use with building automation and security systems.
Dual Technology Ceiling Mount
Input: 24 Vdc Output: +24 Vdc Adjustable Sensitivity Low Profile Housing Adjustable Light Level Sensor UL and cUL Listed CEC Title 24 Certified FCC Part 15, Class B ASHRAE/IES 90.1
Table 5.2:
Catalog No. SLSCPS1000 SLSCUS2000 SLSCDS2000 SLSCUS800 SLSCDS800
Power Pack
For use with wall and ceiling mount sensors to supply power to sensor and switch the load when the sensor detects occupancy. May supply power to multiple sensors and auxiliary relays up to 100mA nominal load.
Input: 120/277 Vac 50/60 Hz Output: 24 Vdc/100mA Nom. Relay rating: 20A Max. Ballast Load at 120Vac (20A Max. at 277V) UL cUL Listed
Auxiliary Relay
For use with wall and ceiling mount sensors to turn lights on when an area is occupied or off when it is not. Requires power pack to supply input power to operate relay.
Power Pack
Input: 24 Vdc/36mA Nom. Relay rating: 20A Max. Ballast Load at 120Vac (20A Max. at 277V) UL cUL Listed
Table 5.3:
5-25
Occupancy Sensors
Lighting Control
Class 1200
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS Indoor Occupancy Sensor
All sensors feature oversized Fresnel lenses and premium, low-noise pyroelectric elements for reliable PIR sensing at mounting heights up to 45 feet. Both area- and aisle-sensing Fresnel lenses ship with each sensor. Color-coded snap-out lenses can be swapped in the field. Switch packs open and close based on fiber optic commands from fiber sensors Universal power supply design adapts to AC line voltages 208-480VAC, 50/60Hz without jumpers or taps. Single-pole/close-on-motion relays sized for switching dry contact, magnetic HID or electronic ballast loads. Mounts directly to reflector with included pinch bracket or to ballast housing with NPT threaded pipe nipple. Built-in manual override test switch and diagnostic LED to assist in installation. Diagnostic LED can be seen at distance to assist in walk test. Fifteen minute power ON warm-up timer assures rated lamp life even if the fiber network is broken. User adjustable sensitivity and delay time settings (0-15 minutes)
Table 5.1:
5-26
Gen 3 Products
Class 1210 Powerlink G3 systems are ideally suited for controlling lighting and other loads in commercial, institutional, and industrial facilities. Such systems are typically used to lower utility cost by switching branch circuits OFF during non-occupied periods when lighting is unnecessary or during peak demand periods when a partial reduction in load can save significant money. These systems utilize remotely operated circuit breakers to switch branch circuits ON and OFF via a time schedule or by an externally generated signal (typically a low voltage wall switch, photocell, access system, fire alarm or building management system). All Powerlink components mount inside a standard lighting panelboard to provide a compact, space saving installation. Powerlink G3 systems feature a powerful microprocessor based controller that provides system intelligence for 168 remotely operated branch circuits. Master panelboards contain the control electronics, power supply, and control bus strips for up to 42 branch circuit breakers. Slave panels extend the capability of the system by allowing remotely operated branch circuit breakers to be operated from the master controller via a simple, 4-wire, sub-net connection. All Powerlink G3 systems have the capability of being networked together and operated from a central workstation or via a remote modem connection. Powerlink software allows users to remotely configure the system, change time schedules, monitor circuit breaker or input status, and override zones and breakers.
BACnet Capability
The Building Automation and Control network (BACnet) communication protocol is incorporated into the Powerlink G3 controller design. The addition of the BACnet protocol allows Powerlink panels to be easily integrated into a Building Automation System (BAS) employing this open communication standard without the need for communication bridges or gateways.
Controller Models
The following Powerlink G3 controller models support native BACnet communications:
NF2000G3 Ethernet communications, shared remote inputs, network time synchronization NF3000G3 Email upon alarm, onboard web pages for status/control/configuration NF3000G3C C-Bus communications (ability to interface with a Clipsal lighting control network)
Powerlink available in column width design
Select system type and interior size from Table 5.100 on 5-66. All Powerlink G3 panels are furnished with either 1 or 2 control bus strips. Select panelboard base price from Table 5.101. All Powerlink G3 panels use NF type panelboard interiors, boxes, and trims and are suitable for either 240V or 480Y/277 V systems. Select branch circuit breaker requirements from Table 5.102. Powerlink G3 panels can accommodate both ECB-G3 remotely operated circuit breakers and EDB, EGB and EJB standard branch circuit breakers. Refer to panelboard section for additional panelboard accessories. For complete price, order by description. Apply appropriate discount schedule.
Table 5.2:
Feature Inputs 2 - wire 2 - wire with status feedback 3 - wire Time Scheduler 7 day, each configurable Daily on/off periods Holiday events Automatic daylight savings Sunrise/sunset tracking Networking Modbus ASCII/RTU Modbus TCP Johnson Controls N2 DMX C-Bus BACnet MSTP/IP a Specify N2 suffix b Specify C suffix 2009 Schneider Electric All Rights Reserved System Level 500 8 8 8 X 1000 16 8 8 16 24 32 X X X Xa X 2000 16 8 8 16 24 32 X X X X X X 3000 16 8 8 16 24 32 X X X X X Xb X
5-27
Gen 3 Products
Class 1210
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS ECB-G3 Circuit Breaker Control Bus Power Supply NF500G3 Controller NF1000G3 Controller
15 20 30
Table 5.2:
Catalog No. $ Price 20 ECB142020G3EL 558.00 Note: All are listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. UL listed as HID rated for use with high intensity discharge lighting systems. (1) #128 Al or (1) #108 Cu. Suitable for use with 75C conductors. a UL listed as SWD (switching duty) rated. b Rated for 240Vac only 42,000AIR
Table 5.3:
Control Bus
Required Interior Size 30 30 42 42 54 54 Panel Orientation Left Right Left Right Left Right Catalog No. NF12SBLG3 NF12SBRG3 NF18SBLG3 NF18SBRG3 NF21SBLG3 NF21SBRG3 $ Price 851.00 1065.00 1162.50
Table 5.4:
Voltage 120V 240V 277V 120V 240V 277V
Power Supply
Primary Source Panel Bus Panel Bus Panel Bus External External External Catalog No. NF120PSG3 NF240PSG3 NF277PSG3 NF120PSG3L NF240PSG3L NF277PSG3L $ Price 791.00 899.00
Table 5.5:
Controller
Description Catalog No. NF500 NF1000 NF1000G3N2 NF2000G3 NF3000G3 NF3000G3C $ Price 1946.00 3968.00 8288.00 7107.00 9741.00 9741.00
Table 5.6: Remote Source Controller (for additional inputs) Includes NEMA 1 enclosure, source controller and power supply
Voltage 120V 240V 277V Catalog No. RSC16G3120 RSC16G3240 RSC16G3277 $ Price 3045.00 3045.00 3045.00
Table 5.7:
Description Catalog No. Control bus cables Harness standard panel NF2HG3 Sub-net accessories & cables Slave address selectore NFSELG3 6 sub-net cable NFSN06 10 sub-net cable NFSN10 25 sub-net cable NFSN25 50 sub-net cable NFSN50 Serial cables Controller front panel cable NFFPCG3 c One slave address selector required for each slave panel.
Table 5.8:
Miscellaneous Hardware
Catalog No. HPAFDf NFASBKG3 NFADAPTERG3 $ Price 25.50 177.00 102.00
Description Circuit Breaker Handle Padlock (Lock On or Off) Fixed Barrier Remote Mounting Adapter d DE2 Discount
Table 5.9:
Software
$ Price 4000.00 1500.00 1523.00
Description Catalog No. LCSAdvanced Software LCSADVANCED LCSBasic Software LCSBasic Powerlink Controller Softwareg PCS101 e N2 supported controllers. All other controllers use LCSAdvanced or LCSBasic.
5-28
DE-8A
DE2
Discount Schedule
Gen 3 Products
Class 1210 Table 5.1:
Voltage 120V 240V 277V 120V 240V 277V 120V 240V 277V 120V 240V 277V 120V 240V 277V 120V 240V 277V
Remote Mount Controller (for externally mounted electronics Includes NEMA 1 enclosure, controller, and power supply
Catalog No. RMC500G3120 RMC500G3240 RMC500G3277 RMC1000N2G3120 RMC1000N2G3240 RMC1000N2G3277 RMC1000G3120 RMC1000G3240 RMC1000G3277 RMC2000G3120 RMC2000G3240 RMC2000G3277 RMC3000G3120 RMC3000G3240 RMC3000G3277 RMC3000G3C120 RMC3000G3C240 RMC3000G3C277 Controller Type NF500G3 NF500G3 NF500G3 NF1000N2G3 NF1000N2G3 NF1000N2G3 NF1000G3 NF1000G3 NF1000G3 NF2000G3 NF2000G3 NF2000G3 NF3000G3 NF3000G3 NF3000G3 NF3000G3C NF3000G3C NF3000G3C $ Price 3272.00 3272.00 3272.00 9615.00 9615.00 9615.00 5294.00 5294.00 5294.00 8435.00 8435.00 8435.00 9606.00 9606.00 9606.00 9606.00 9606.00 9606.00
Surface-mount NEMA 1 enclosure, with cover Unit and C-Bus LEDs indicate the status of the line voltage and the network Sources up to 700 mA (dual power supplies) to the C-Bus network 120V or 277Vac models available Dimensions: 8.9 in. (226mm) wide x 3.8 in. (97mm) deep x 12.57 (319mm) tall
Device Router
The Powerlink Device Router allows the exchange of data between a Powerlink NF3000G3C controller and C-Bus devices. This device router receives data from C-Bus input devices such as keypads and touchscreens and sends data to the Powerlink system and isa versa. The device router consists of a C-Bus 8M enclosure containing a C-Bus PC Interface and a C-Bus Power Supply (120Vac or 277Vac). Communication between the device router and the NF3000G3C controller is made with the included 50-foot serial cable.
Surface-mount NEMA 1 enclosure, with cover Unit, Unit/Comms, and C-Bus LEDs indicate the status of data transmission and power to the unit and the network System network clock for synchronizing communications data Network power source, supplying up to 350 mA 120Vac or 277Vac models available Dimensions: 8.9 in. (226mm) wide x 3.8 in. (97mm) deep x 12.57 in. (319mm) tall
Table 5.2:
Description 120V Device Router 277V Device Router a Required for interface to Clipsal units. b DE-8 Discount.
Table 5.3:
Powerlink Device Router
Single Supply 120V Dual Supply 120V Single Supply 277V Dual Supply 277V Filler Plate c Extends C-Bus power to Clipsal devices. d DE-8 Discount.
Table 5.5:
Description Catalog No. $ Price Modem Kit (for G3 Controllers) 6382G3MODEM 876.00 e Requires 2000 and 3000 controller and either Analog or Ethernet modem connection to each master panel.
DE-8
5-29
Class 1210
www.schneider-electric.us
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
Table 5.2:
Mains Rating
Circuit Circuit 2-pole 3-pole 2-pole 3-pole 2-pole Bkr. Bkr. 100A EDb 2454.00 2823.00 EGb 3150.00 125A 1269.00 1458.00 EDb 5058.00 5643.00 EGb 6486.00 150A HD 4905.00 5430.00 HG 6072.00 225A JD 6180.00 6570.00 JG 7605.00 250A 1503.00 1728.00 JD 6750.00 7710.00 JG 8985.00 400A 1989.00 2286.00 LA 7995.00 9189.00 LH 11568.00 600Ac 3549.00 3933.00 800Ac 5325.00 5850.00 a HL and JL frame circuit breakers are also available as main circuit breakers. b Backfed Main Circuit Breaker54 circuit only. c Copper Bus Only. d For N2 protocol, add $3819. e Contact your nearest Square D/Schneider Electric sales office for MICROLOGICTM trip main circuit breakers
Table 5.3:
Ampere 1-pole 2-pole 3-pole Voltage Ampere Ampere Ampere 1-pole 2-pole 3-pole Voltage 1-pole 2-pole 3-pole Voltage 1-pole 2-pole 3-pole Rating Rating Rating Rating 1520 438. 1215. 1929. 1560 288. 663. 1122. 1560 486. 1119. 1896. 1560 777. 1767. 3036. 240 Vac 30 438. 1215. 1929. 480Y/ 70 513. 1308. 1569. 480Y/ 70 867. 2211. 2565. 480Y/ 70 1386. 3540. 4245. 1520 438. 1215. 1929. 277 80100 1308. 1569. 277 80100 2211. 2655. 277 80100 3540. 4245. 480Y/277 Vac Vac Vac Vac 30 438. 1215. 110125 3825. 4845. 110125 6171. 7131. 110125 7950. 9450. Space Only 63. 126. 189. Space Only 63. 126. 189. Space Only 63. 126. 189. Space Only 63. 126. 189. Note: All EC, ED, EG and EJ branch circuit breakers are UL Listed as HACR type.
Available on 1 or 3, 125800A main lugs or 125600A main circuit breaker interiors One sub-feed JD, JG, JJ or JL circuit breaker per 250A panelboard Two sub-feed JD, JG, JJ or JL circuit breakers per 400A panelboardf
LC and JJ may not be combined.
To obtain pricing for the following Special Features please refer to the Supplemental Digest.
Table 5.4:
No. of Poles JD JG JJg JL LA LH LCg 2 2265.00 3165.00 3844.50 4230.00 2985.00 4150.50 6475.50 3 2527.50 3825.00 4665.00 5296.50 3687.00 4882.50 7617.00 g JJ and LC sub-feed circuit breakers cannot be used together.
Table 5.5:
Max. No. of Branch Spaces (Does not include sub-feed breaker spaces)
h i j k
30 56 68 68 80 68 42 62 74 74 86 74 54 68 80 80 92 80 Dimensions also for 400A LC/LI main circuit breaker panels. 600A main lug panelboards require an 8" deep, 26 wide box. 600A main lug panelboards require an 8.75" deep box. 800A main lug panelboards require an 8.75 deep, 26 wide box.
PowerLogic metering Customer equipment space Increased box depth Box extensions top, bottom and side Drip hoods Non-standard paint NEMA 1 gasketed NEMA 4 Stainless steel enclosure NEMA 4X Fiberglass enclosure (NQOD and NF) Stainless steel trim front (NQOD, NF and I-LINE) Padlockable hasp Special locks (Corbin, Yale, Best) Equal height boxes Common trip to cover two equal height boxes Panelboard skirthides conduits feeding a panelboard Panelboard wireway for terminating conduit in wireway endwall Panelboard interiors and special fronts to fit existing boxes
5-30
Structured Wiring
www.squaredlightingcontrol.com
SDM46P
SDM8D
SDM38VBIR/SDM38VHIR
SDM46P14V
Mounting Brackets and Enclosures Surface mounting bracket, 61/2"w x 10"h, white SDM10BW Cover for SDM10BW, white SDM10CW Enclosure w/mounting grid, 14"w x 18"h, white SDM18BW Cover for SDM18BW, white SDM18CW Enclosure w/mounting grid, 14"w x 36"h, white SDM36BW Cover for SDM36BW, white SDM36CW Combination Video/Telephone Hubs Combo hub, video splitter (1 input x 4 TVs) / phone (2 lines x 6 phones), SDM26P14V grid mount Combo hub, video splitter (1 input x 4 TVs) / phone (4 lines x 6 phones), SDM46P14V grid mount Telephone Hubs Telephone master hub, 4 lines x 6 phones, grid mount SDM46P Telephone expansion hub, 4 lines x 8 phones, grid mount SDM48PX Telephone interface hub, 4 lines x 11 phones, grid mount, RJ45 jacks SDM412PJ Video Hubs Video splitter, (1 input x 3 TVs), grid mount SDM13VS Video splitter, (1 input x 4 TVs), grid mount SDM14VS Video splitter, (1 input x 8 TVs), grid mount SDM18VS Video amplifier hub (1 input x 6 TVs), bi-directional CATV or antenna, SDM16VAB grid mount, 120 Vac power supply included Video amplifier hub (3 inputs x 8 TVs), bi-directional CATV, grid mount, SDM38VBIR 120 Vac power supply included Video amplifier hub (3 inputs x 8 TVs), CATV or antenna, grid mount, SDM38VHIR 120 Vac power supply included Data Hubs Data termination hub provides termination point for Cat-5 wiring, 100 Base-T certified, 8 bridgeable circuits (8 - 110 punch down blocks SDM8D connected to 8 - RJ-45 jacks) Data termination hub provides termination point for Cat-5 wiring, 100 Base-T certified, 16 bridgeable circuits (16 - 110 punch down blocks SDM8DB connected to 8 - RJ-45 jacks) Accessories AC outlet accessory, mounts in enclosures, 2 duplex receptacles SDM4AC (not included) accepts 2 power supplies, UL Listed, 120 Vac AC outlet accessory, mounts in enclosures, 4 duplex receptacles SDM8AC (not included) accepts 4 power supplies, UL Listed, 120 Vac Telephone surge accessory, mounts in enclosures, SDMSA4P 4-line telephone protector with tool-less IDC terminations Video surge accessory, mounts in enclosures, SDMSA2V dual line cable TV protection Video surge accessory, mounts in enclosures, SDMSA2VD dual line satellite protection Adapter bracket to mount ChannelPlus 3400 or 8200 on SDM1A Square D Multi-Link grid Adapter bracket to mount RJ and type F connectors on SDM6A Square D Multi-Link grid Wire Spacer Mezzanine, Universal Grid, lifts modules 1" above grid, SDM12WS providing wire management capabilities, 11.2"h x 6.5"w Universal heavy duty isolation mounting bracket for non-Square D SDM1IMB Multi-Link products. Load rated 60 pounds. Universal light duty isolation mounting bracket for non-Square D SDM2IMB Multi-Link products. Load rated 10 pounds. Patch Cord 1 foot length, Cat-5, RJ-45 plugs on both ends SDM1DC Patch Cord 2 foot length, Cat-5, RJ-45 plugs on both ends SDM2DC Enclosure Coupling Tube for stacking enclosures, 2 inch conduit SDM2C Plastic grommet for 2" enclosure knockout, (5) pack SDM2G Cover Lock Kit SDMLK Replacement snap locks, lock Square D Multi-Link modules to grid, SDM10SL black (10) pack Low Pass Filter, Channel 91 SDM600LPF a Two columns of grid mounting space, 17" of space per column. b Two columns of grid mounting space, 35" of space per column.
10 1 1 1 1 1
87.00 116.00
3 3
1 1
3 3 3 2 2 2 3 2.5 2.5
1 1 1 1 1 1 1 1 1
101.00 131.00
3 4.5
1 1
45.80 55.00 100.50 100.50 100.50 28.70 28.70 43.80 87.00 42.90 11.60 14.40 22.80 4.40 43.80 17.10 58.00
5.5 11a 2 2 2 2 2 12 b b
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
DE7
Discount Schedule
5-31
www.squaredlightingcontrol.com
5
LIGHTING CONTROL AND INTEGRATED HOME SYSTEMS
5-32
Table of Contents
Section 6
Surge Protective Devices
Commercial Applications
EMA/EBA, page 62
IPaCSRefer to 10-1
OEM/Assembler Kit
6-1
Surgelogic
Surgelogic Surge Protective Device (SPD) products offer high performance solutions for electrical distribution systems. From simple to mission-critical applications in commercial, industrial, and OEM design, the comprehensive Surgelogic line provides devices for every need.
10 year product warranty Suppression modes: L-N, L-G, L-L, and N-G 200 kA SCCR EMI/RFI filtering
Audible alarm with enable/disable switch, dry contacts, and surge counter standard Indicator LEDs; normal (green) and fault condition (red) for each phase
Peak Surge Current NEMA 4X NEMA 1/3R Rating $ Price Stainless Steel $ Price Cat. No. per Phase Cat. No. (kA) Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter. 120 TVS1EMA12A( ) 4547.00 TVS1EMA12S( ) 5964.00 120/240 V, 160 TVS1EMA16A( ) 4997.00 TVS1EMA16S( ) 6414.00 1-phase, 3-wire 240 TVS1EMA24A( ) 7421.00 TVS1EMA24S( ) 8838.00 +ground 320 TVS1EMA32A( ) 9962.00 480 TVS1EMA48A( ) 14798.00 120 TVS2EMA12A( ) 4760.00 TVS2EMA12S( ) 6177.00 208Y/120 V, 160 TVS2EMA16A( ) 5231.00 TVS2EMA16S( ) 6648.00 3-phase, 4-wire 240 TVS2EMA24A( ) 7782.00 TVS2EMA24S( ) 9200.00 +ground b 320 TVS2EMA32A( ) 10431.00 480 TVS2EMA48A( ) 15522.00 120 TVS3EMA12A( ) 4760.00 TVS3EMA12S( ) 6177.00 120/240 V, 160 TVS3EMA16A( ) 5231.00 TVS3EMA16S( ) 6648.00 3-phase, 4-wire 240 TVS3EMA24A( ) 7782.00 TVS3EMA24S( ) 9200.00 +ground 320 TVS3EMA32A( ) 10431.00 High-leg Delta 480 TVS3EMA48A( ) 15522.00 120 TVS4EMA12A( ) 4973.00 TVS4EMA12S( ) 6390.00 480Y/277 V, 160 TVS4EMA16A( ) 5468.00 TVS4EMA16S( ) 6885.00 3-phase, 4-wire 240 TVS4EMA24A( ) 8147.00 TVS4EMA24S( ) 9564.00 +ground a b 320 TVS4EMA32A( ) 10904.00 480 TVS4EMA48A( ) 16250.00 120 TVS8EMA12A( ) 5220.00 TVS8EMA12S( ) 6638.00 600Y/347 V, 160 TVS8EMA16A( ) 5714.00 TVS8EMA16S( ) 7131.00 3-phase, 4-wire 240 TVS8EMA24A( ) 8528.00 TVS8EMA24S( ) 9945.00 +ground b 320 TVS8EMA32A( ) 11399.00 480 TVS8EMA48A( ) 17012.00 a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240 b Can be used on 4-wire or 3-wire grounded neutral system. ( ) For option, select and add the appropriate suffix from the option listing below: Option (I) Integral Switch $ Price 738.00
10 year product warranty Audible alarm, dry contacts and surge counter are included in the standard diagnostic package 200 kA SCCR
Table 6.3:
Peak Surge Current NEMA 4X Service NEMA 1/3R Rating $ Price Stainless Steel $ Price Voltage Cat. No. per Phase Cat. No. (kA) Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter. 120 TVS2MEMA12A( ) 8810. TVS2MEMA12S( ) 10010. 208Y/120 V, 180 TVS2MEMA18A( ) 10790. TVS2MEMA18S( ) 12657. 3-phase, 270 TVS2MEMA27A( ) 13760. TVS2MEMA27S( ) 15627. 3-4 wire 360 TVS2MEMA36A( ) 16730. TVS2MEMA36S( ) 18597. 120 TVS4MEMA12A( ) 9023. TVS4MEMA12S( ) 10890. 480Y/277 V, 180 TVS4MEMA18A( ) 11003. TVS4MEMA18S( ) 12870. 3-phase, 270 TVS4MEMA27A( ) 13973. TVS4MEMA27S( ) 15840. 3-4 wire a 360 TVS4MEMA36A( ) 16943. TVS4MEMA36S( ) 18810. a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240 ( ) For option, select and add the appropriate suffix from the following listing: Option (SWT) Sine Wave Tracking Description Remote Monitor 12" Flush Mounting Collar 20" Flush Mounting Collar $ Price 750.00 Cat. No. TVS12RMU TVS12FMK TVS20FMK $ Price 788. 945. 1103.
Option Descriptions
Integral Switch. The integral switch provides a mechanical means to electrically isolate the entire surge suppressor before opening the enclosure door to facilitate servicing of the units components. Remote Monitor. This option displays the alarm status of the surge protective device up to 1000 feet from the unit. Flush Mounting. Flush mounting collar can be used on 120240 kA EMA and EBA series devices. Devices with integral switch require 20 flush mounting collar.
Peak Surge NEMA 4X NEMA 1/3R Current Rating $ Price Stainless Steel $ Price Cat. No. per Phase (kA) Cat. No. Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter. 120/240 V, 120 TVS1EBA12A( ) 3467.00 TVS1EBA12S( ) 4884.00 1-phase, 3-wire 160 TVS1EBA16A( ) 4208.00 TVS1EBA16S( ) 5625.00 +ground 240 TVS1EBA24A( ) 6290.00 TVS1EBA24S( ) 7707.00 208Y/120 V, 120 TVS2EBA12A( ) 3588.00 TVS2EBA12S( ) 5006.00 3-phase, 4-wire 160 TVS2EBA16A( ) 4388.00 TVS2EBA16S( ) 5805.00 +ground a 240 TVS2EBA24A( ) 6525.00 TVS2EBA24S( ) 7943.00 120/240 V, 3-phase, 120 TVS3EBA12A( ) 3588.00 TVS3EBA12S( ) 5006.00 4-wire +ground 160 TVS3EBA16A( ) 4388.00 TVS3EBA16S( ) 5805.00 High-leg Delta 240 TVS3EBA24A( ) 6525.00 TVS3EBA24S( ) 7943.00 480Y/277 V, 120 TVS4EBA12A( ) 3743.00 TVS4EBA12S( ) 5160.00 3-phase, 4-wire 160 TVS4EBA16A( ) 4581.00 TVS4EBA16S( ) 5999.00 +ground a b 240 TVS4EBA24A( ) 6827.00 TVS4EBA24S( ) 8244.00 600Y/347 V, 120 TVS8EBA12A( ) 3905.00 TVS8EBA12S( ) 5322.00 3-phase, 4-wire 160 TVS8EBA16A( ) 4787.00 TVS8EBA16S( ) 6204.00 +ground a 240 TVS8EBA24A( ) 7143.00 TVS8EBA24S( ) 8561.00 a Can be used on 4 wire or 3 wire grounded neutral system. b 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240 ( ) For options, select and add the appropriate suffix from the option listing below: Option (I) Integral Switch $ Price 738.00
6-2
DE1B
Discount Schedule
Replacement Modules
Refer to Catalog 6671CT9701
New! All modules and brick assemblies are US and Canadian UL Recognized to UL 1449 3rd Edition and UL 1283 5th Edition. Complies with requirements of NEC Article 285 and CSA C22.2 No. 8-M1986 as appropriate.
Replacement Modules
Table 6.4:
Table 6.5:
Peak Surge Current Rating (kA) Catalog Numbers 120 MA1IBA12 160 MA1IBA16 240 MA1IBA24 120 MA2IBA12 208Y/120 V, 3-phase, 160 MA2IBA16 3-4 wire 240 MA2IBA24 120 MA3IBA12 240/120 V, 3-phase, 4-wire, 160 MA3IBA16 high-leg delta 240 MA3IBA24 120 MA4IBA12 480Y/277 V, 3-phase, 160 MA4IBA16 3-4 wire a 240 MA4IBA24 120 MA8IBA12 600Y/347 V, 3-phase, 160 MA8IBA16 3-4 wire 240 MA8IBA24 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240. 120/240 V, 1-phase, 3-wire
System Voltage
Table 6.6:
Peak Surge Catalog Numbers System Current Rating Voltage Phase A $ Price Phase B $ Price (kA) 120 MA1IMA12 906.00 MA1IMA12 906.00 208Y/120 V, 180 MA1IMA16 1064.00 MA1IMA16 1064.00 3-phase, 270 MA1IMA16 1064.00 MA1IMA16 1064.00 3-4 wire 360 MA1IMA24 1229.00 MA1IMA24 1229.00 120 MA4IMA12 906.00 MA4IMA12 906.00 480Y/277 V, 180 MA4IMA16 1064.00 MA4IMA16 1064.00 3-phase, 270 MA4IMA16 1064.00 MA4IMA16 1064.00 3-4 wire a 360 MA4IMA24 1229.00 MA4IMA24 1229.00 120 MA8IMA12 906.00 MA8IMA12 906.00 600Y/347 V, 180 MA8IMA16 1064.00 MA8IMA16 1064.00 3-phase, 270 MA8IMA24 1229.00 MA8IMA24 1229.00 3-4 wire 320 MA8IMA24 1229.00 MA8IMA24 1229.00 a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240
Table 6.7:
System Voltage
Peak Surge Catalog Numbers Current Rating Phase A $ Price Phase B $ Price (kA) 120 MA2IMA40LL 604.00 MA2IMA40LL 604.00 208Y/120 V, 180 MA2IMA60LL 709.00 MA2IMA60LL 709.00 3-phase, 270 MA2IMA90LL 819.00 MA2IMA90LL 819.00 3-4 wire 360 MA2IMA12LL 946.00 MA2IMA12LL 946.00 120 MA4IMA40LL 604.00 MA4IMA40LL 604.00 480Y/277 V, 180 MA4IMA60LL 709.00 MA4IMA60LL 709.00 3-phase, 270 MA4IMA90LL 819.00 MA4IMA90LL 819.00 3-4 wire a 360 MA4IMA12LL 946.00 MA4IMA12LL 946.00 a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240
PE4
PE7
PE1A
Discount Schedule
6-3
Peak Surge Catalog Numbers System Current Rating Voltage Phase A $ Price Phase B $ Price (kA) 120 MA1IMA12 906.00 120/240 V, 1-phase, 160 MA1IMA16 1064.00 3-wire 240 MA1IMA24 1229.00 120 MA1IMA12 906.00 MA1IMA12 906.00 208Y/120 V, 3-phase, 160 MA1IMA16 1064.00 MA1IMA16 1064.00 4-wire 240 MA1IMA24 1229.00 MA1IMA24 1229.00 120 MA1IMA12 906.00 MA3IMA12 906.00 120/240 V, 3-phase, 160 MA1IMA16 1064.00 MA3IMA16 1064.00 4-wire b 240 MA1IMA24 1229.00 MA3IMA24 1229.00 120 MA4IMA12 906.00 MA4IMA12 906.00 480Y/277 V, 3-phase, 160 MA4IMA16 1064.00 MA4IMA16 1064.00 4-wire a 240 MA4IMA24 1229.00 MA4IMA24 1229.00 120 MA8IMA12 906.00 MA8IMA12 906.00 600/347 V, 3-phase, 160 MA8IMA16 1064.00 MA8IMA16 1064.00 4-wire 240 MA8IMA24 1229.00 MA8IMA24 1229.00 a 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240 b High-leg delta (Phase B modules are different than Phase A and Phase C modules)
Internally mounted surge protective devices are installed integrally to systems for service entrance and branch panel surge suppression. External SPDs cannot compete with the performance of integrally/internally mounted products installed next to the supply busses inside Square D systems. Built-in performance is the best way to ensure cost effective power quality (especially important for critical power facilities). US and Canadian UL Recognized to UL 1449 3rd Edition and UL 1283 5th Edition. Complies with requirements of NEC Article 285 and CSA C22.2 No. 8-M1986 as appropriate.
6
SURGE PROTECTIVE DEVICES
NF BuswayRefer to Section 12
NQ
PZ4
QED
MCC
IPAC2
Internally MountedRetrofit
To ensure high-performance surge suppression at critical power locations, A variety of Surgelogic products are offered which are designed specifically for retrofitting into commonly used Square D systems. Retrofitting SPD units on I-Line, QMB, MCC, and Busway applications is simple. The QMB fusible switch, 6 in. MCC bucket, I-Line and Busway plug-on units come with the SPD factory-built into these devices.
Audible alarm with enable/disable switch, dry contacts, and surge counter standard. 200 kA SCCR Internally MountedRetrofit
Table 6.8:
Surge I-Line Branch Unitsb QMB Branch Unitsc Voltage Current Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Rating Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter. 120 kA HL1IMA12C 9518.00 FI1IMA12C 10185.00 QMB1IMA12C 6663.00 120/240 V, HL1IMA16C 10455.00 FI1IMA16C 11199.00 QMB1IMA16C 7340.00 1-phase, 3-wire 160 kA 240 kA HL1IMA24C 14100.00 FI1IMA24C 15525.00 QMB1IMA24C 10055.00 120 kA HL2IMA12C 9893.00 FI2IMA12C 10562.00 QMB2IMA12C 6899.00 208Y/120 V, 3-phase, 4-wire 160 kA HL2IMA16C 10872.00 FI2IMA16C 11616.00 QMB2IMA16C 7602.00 a 240 kA HL2IMA24C 15423.00 FI2IMA24C 16170.00 QMB2IMA24C 10460.00 120 kA HL3IMA12C 9893.00 FI3IMA12C 10562.00 QMB3IMA12C 6899.00 240/120 V, 3-phase, 4-wire 160 kA HL3IMA16C 10872.00 FI3IMA16C 11616.00 QMB3IMA16C 7602.00 High-leg Delta 240 kA HL3IMA24C 15423.00 FI3IMA24C 16170.00 QMB3IMA24C 10460.00 120 kA HL4IMA12C 10271.00 FI4IMA12C 10944.00 QMB4IMA12C 7137.00 480Y/277 V, 3-phase, 4-wire 160 kA HL4IMA16C 11292.00 FI4IMA16C 12039.00 QMB4IMA16C 7868.00 ad 240 kA HL4IMA24C 16070.00 FI4IMA24C 16818.00 QMB4IMA24C 10868.00 120 kA FI8IMA12C 11342.00 QMB8IMA12C 7388.00 600Y/347 V, 3-phase, 4-wire 160 kA FI8IMA16C 12482.00 QMB8IMA16C 8145.00 a 240 kA FI8IMA24C 16692.00 QMB8IMA24C 11295.00 a b c d Can be used on 4-wire or 3-wire grounded neutral system. Requires 13.5" mounting height. Requires 9" mounting height. 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240 e f g
Busway Units Cat. No. PIU2IMA16 PIU2IMA24 PIU3IMA16 PIU3IMA24 PIU4IMA16 PIU4IMA24 PIU8IMA16 PIU8IMA24 $ Pricef 4472.00 6407.00 4472.00 6407.00 4740.00 6792.00 4919.00 7048.00
Model 6 MCC Unitse Cat. No. MCC2IMA12C MCC2IMA16C MCC2IMA24C MCC3IMA12C MCC3IMA16C MCC3IMA24C MCC4IMA12C MCC4IMA16C MCC4IMA24C MCC8IMA12C MCC8IMA16C MCC8IMA24C $ Priceg 6700.00 8700.00 12200.00 6700.00 8700.00 12200.00 7200.00 9200.00 13200.00 7700.00 9700.00 14200.00
Requires 6" mounting height. PE7 Discount Schedule PE4 Discount Schedule
6-4
PE4
PE7
PE1A
Discount Schedule
OEM/Assembler Kit
Surgelogic OEM/assembler kits allow manufacturers to add industry-leading surge suppression directly to customized equipment. Manufacturers benefit from shorter wire lengths that optimize the clamping voltage of the SPD. Products come with a backplanemounted SPD, mounting hardware and diagnostic display with 36" cables. Audible alarm, silence switch, remote monitoring contacts, and surge counter are standard. US and Canadian UL Recognized to UL 1449 3rd Edition and UL 1283 5th Edition. Complies with requirements of NEC Article 285 and CSA 22.2 No. 8-M1986 as appropriate. Table 6.9: OEM/Assembler Kits
OEM Kit
Nipple Mounted Surge Protective Devices HWA Series, Nipple-Mounted Surge Protective Device
Surgelogic HWA series surge protective devices are compact, nipple-mounted parallelconnected surge suppressors that come in a variety of voltage configurations, including Delta. A surge suppression path is provided for each mode, line-to-neutral (LN), line-to-line (LL), line-to ground (LG), and neutral-to-ground (NG) in a NEMA 4X housing. On-line diagnostics continuously monitor the device status. US and Canadian UL Listed to UL 1449 3rd Edition and UL 1283 5th Edition. Complies with requirements of NEC Article 285 and CSA C22.2 No. 8-M1986 as appropriate.
HWA Series
Audible alarm indicates a fault condition Compact design provides easy mounting inside or outside the equipment cabinets Dry contacts Does not contain alarm enable/disable switch Optional flush mount kit TVSHWAFMK EMI/RFI filtering LEDs indicate operational status 200 kA SCCR
Table 6.10:
Service Voltage
Peak Surge Current Rating NEMA 3R, per Phase (kA) 4X Cat. No. 50 TVS1HWA50X 120/240 V, 1-phase, 3-wire 80 TVS1HWA80X +ground 100 TVS1HWA10X 50 TVS2HWA50X 208Y/120 V, 3-phase, 4-wire 80 TVS2HWA80X +ground a 100 TVS2HWA10X 50 TVS3HWA50X 120/240 V, 3-phase, 4-wire +ground 80 TVS3HWA80X High-leg Delta 100 TVS3HWA10X 50 TVS6HWA50X 240 V, 80 TVS6HWA80X 3-phase, 3-wire Delta 100 TVS6HWA10X 50 TVS4HWA50X 480Y/277 V, 3-phase, 4-wire 80 TVS4HWA80X +ground ab 100 TVS4HWA10X 50 TVS5HWA50X 480 V, 3-phase, 3-wire 80 TVS5HWA80X Delta 100 TVS5HWA10X 50 TVS8HWA50X 600Y/347 V, 3-phase, 4-wire 80 TVS8HWA80X +ground 100 TVS8HWA10X 50 TVS9HWA50X 600 V, 3-phase, 3-wire 80 TVS9HWA80X Delta 100 TVS9HWA10X a Can be used on 4-wire or 3-wire grounded neutral system. b 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240
OE1A
Discount Schedule
6-5
Service Peak Surge Current Rating Cat. No.b $ Price Voltage per Phase (kA) Note: Supplied with audible alarm, alarm enable/disable switch, dry contacts, and surge counter. 120 TVS1IMA12O 4137.00 120/240 V, 1-phase, 3-wire 160 TVS1IMA16O 4547.00 +ground 240 TVS1IMA24O 6753.00 120 TVS2IMA12O 4331.00 208Y/120 V, 3-phase, 4-wire 160 TVS2IMA16O 4760.00 +ground a 240 TVS2IMA24O 7082.00 120 TVS3IMA12O 4331.00 120/240 V, 3-phase, 4-wire 160 TVS3IMA16O 4760.00 +ground High-leg Delta 240 TVS3IMA24O 7082.00 120 TVS4IMA12O 4526.00 480Y/277 V, 3-phase, 4-wire 160 TVS4IMA16O 4976.00 +ground ac 240 TVS4IMA24O 7413.00 120 TVS8IMA12O 4751.00 600Y/347 V, 3-phase, 4-wire 160 TVS8IMA16O 5199.00 +ground a 240 TVS8IMA24O 7760.00 a Can be used on 4-wire or 3-wire grounded neutral system. b Note the last character of the catalog number is the letter O, not a zero. c 480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240
SDSA1175
LED indicates operational status Suitable for indoor and outdoor applications (NEMA 4X housing) Convenient back nipple mounting Short circuit current rating 22 kA
Table 6.11:
Service Voltage
120/240 V, 36 SDSA1175 a 92.00 1-phase, 3-wire a See Table 6.14 for QOSAMK mounting kit for installation in QO load centers.
6
SURGE PROTECTIVE DEVICES XR Series
Short circuit current rating 22 kA Suitable for indoor and outdoor applications (NEMA 4X housing) Optional flush mount kit TVSXRFMK LEDs indicate operational status Convenient side nipple mounting
Table 6.12:
Service Voltage
The SDSA3650 SPD is designed and listed for indoor or outdoor installation and surge suppression for three-phase grounded electrical services up to 600 Vac. The SDSA3650 series is used extensively in service entrance panels to provide an efficient and economical means of surge suppression. US and Canadian UL Listed to UL 1449 3rd Edition. Complies with requirements of NEC Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as appropriate.
Suitable for indoor and outdoor applications (NEMA 4X housing) LEDs indicate operational status Convenient back nipple mounting Short circuit current rating 200 kA
Table 6.13:
Peak Surge Current Rating Cat. No. per Phase (kA) 600 Vac Maximum, 3-phase, 4-wirec 40 SDSA3650 b 600 Vac Maximum, 3-phase, 3-wire Delta 40 SDSA3650Db b See Table 6.14 for QOSAMK mounting kit for installation in QO load centers. c Do not use on ungrounded systems. Systems must be solidly grounded.
QOSAMK
Description Mounts to QO and Homeline load centers and other enclosures Flush-mount kit for XR SPDs Flush-mount kif for HWA SPDs
6-6
DE1B
Discount Schedule
Residential SPDs
Class 6671 Refer to Catalog 6671CT9701
New!
SDSB1175C SDSB1175R
80 kA per phase AC line suppression for single-phase, three-wire 120/240 Vac applications Four-line telephone module with tool-less insulation displacement connectors (IDC) Two-line coaxial modules LED status indicators for AC surge suppression Space for additional telephone surge suppressor module Space for additional coaxial surge suppressor module
Table 6.15:
Description Whole House NEMA 1 Surge Protective Device Whole House NEMA 3R Surge Protective Device
New!
SDSA2V
SDSA4P
QO2175SB for QO load centers, combination devices, and NQ panelboards HOM2175SB for Homeline load centers and combination devices Plug-on design requires two pole spaces LED indicates operational status 27 kA per phase
Table 6.17:
QO2175SB HOM2175SB
DE1B
Discount Schedule
6-7
Description 4-Line telephone surge suppressor with tool-less IDC terminations Coaxial video surge suppressor
www.schneider-electric.us
6
SURGE PROTECTIVE DEVICES
6-8
Table of Contents
Section 7
Miniature and Molded Case Circuit Breakers
Selection Information QO and QOU Miniature Circuit Breakers
QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Multi 9TM Mounting Bases
H-Frame J-Frame
7-2 7-10 7-10 7-12 7-13 7-14 7-15 7-16 7-21 7-21 7-22 7-24 7-25 7-26 7-27 7-28 7-28 7-29 7-30 7-31 7-32 7-33 7-34 7-35 7-36 7-43 7-45 7-46 7-49 7-49 7-49 7-51 7-51 7-52 7-54 7-56
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
QOU Miniature Circuit Breakers and QYU Supplementary Protectors QOU Accessories
Multi 9TM Miniature Circuit Breakers PowerPact Molded Case Circuit Breakers
PowerPact Family H- and J-Frame Circuit Breakers G- and Q-Frame Circuit Breakers
D-Frame
D- and M-Frame Circuit Breakers P-Frame Circuit Breakers R-Frame Circuit Breakers
Automatic Switches 500 Vdc Circuit Breakers Mission Critical Circuit Breakers PowerPact Circuit Breaker Accessories Micrologic Electronic Trip Units Masterpact Universal Power Circuit Breakers Ground-fault Protection
P-Frame
7-1
Selection Information
QO Circuit Breakers
Plug-on Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 120 Vac 120/240 Vac 208Y/120 240 Vac d 277 Vac 480Y/277 Vac 48 Vdc 60 Vdc 65 Vdc 125 Vdc 250 Vdc IEC (Icu) Bolt-on Unit Mount
HOMAFI 1 1520
QO-H
QH QHB 3 1530
DC Ratings
IEC 60947-2 (50/60 Hz)g Special Ratings Fed. Specs W-C-375B/GEN Other Standard
10 10
10 10
10
10
10 10
10
10 10
10 10
10 10 5f
10 10 5f
10 10 10 5f
10 10 10
22 22
22 22
22 22 22
22 22 65 22 22 65 22e
65 65 65
10 10
10
22
10
10 10
10
22
10
HACR i
X HACR i X
HACR h NOM X X X
HACR h
HACRi NOM Xl X X X X X X X X X X X X X X X X
NOM
NOM
Accessories and Modifications Shunt Trip j Undervoltage Trip Auxiliary Switches j Alarm Switch j Handle Operators Handle Padlock Attachment Trip System Type Thermal-magnetic Molded Case Switch Dimensions (1P Unit Mount) 3.13 (79) 3.5 (89) a 4.75 (121) 1.00 (25) 0.75 (19) a 2.98 (76) 2.92 (74) a Pages Page 1-13 Pages 7-10, 7-11 a See page 7-54 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH. b HOMT tandem is 30 A maximum. HOMT quad tandem has 20 A maximum on outside poles, and 50 A maximum on the inside poles. c AFI, EPD and GFI products are rated 60 Hz only. d See the Supplemental Digest for 3 corner grounded systems. e 22 kA @ 240 Vac for 3P only. 1P and 2P, 1070 A and 3P 1060 A only. f g See the Supplemental Digest for circuit breakers with IEC ratings. h HACR on HOM 1P 1550 A and 2P 15100 A i HACR on QO, QOB 1P 1070 A, 2P 15100 A, 3P 10100 A; QOB-VH 1P 1570 A, 2P 15125 A, 3P 15100 A j Factory-installed option only k Factory-installed accessories are not available on QOB-VH 2P150 A and 3P 110150 A l Handle padlock attachment available for HOMT quad tandem only. m 2P 150200 A requires 4P width. Dimensions (1P Unit Mount) in. (mm) Height Width Depth 4.12 (103) X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Xk Xk Xk X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
7-2
Selection Information
www.schneider-electric.us
Plug-on Circuit Breaker Type Bolt-on Unit Mount Number of Poles Current Range Interrupting Ratings 120 Vac UL/CSA 120/240 Vac Rating 240 Vacc (kA RMS) 277 Vac (50/60 Hz) 480Y/277 Vac 48 Vdc 60 Vdc 65 Vdc DC Ratings 125 Vdc 250 Vdc 500 Vdc IEC 60947-2 240 Vac (50/60 Hz) 415 Vac Icu 1 10100
QYUa 1 1030
QOM1-VH 2 50125
New!
C60H-DC 1 0.540 2 0.540 1 1570 25 18 18 18 20 10
EDB
10 10 5d 5e
10 10 5d 5e
10 10 10 5d 5e
22 22
22 22
10 5 5 10 10 20
10 10 10 10 10 20 10
10 10 10 20 10
10 10 10 5 10 10 10
10 10 10 5 5 10 10 10 10 5
10 10 10 5 5 10 5
5 5 5 5 5 20
5 5 5 5 5 5k 10
25 25 25 18 18
65 35 35 35
65 65 65 35 35
Special Ratings Fed. Specs X X X X X X X X X X W-C-375B/GEN Other Standard HACR f g Accessories and Modifications Shunt Trip Xh Xh Xh Xh X h X X X X X X X X X h Undervoltage Trip X X X X X X X X Auxiliary Switches Xh Xh Xh Xh X X X X X X X X Xh Alarm Switch Xh Xh Xh Xh X X X X X X X X Xh Handle Operators X X X X X X X X Handle Padlock X X X X X X X X X X X X X X X Attachment Trip System Type Thermal-magnetic X X X X X X X X X X X X X X X Molded Case Switch X X Dimensions (1P Unit Mount) Dimensions Height 4.05 (103) 5.09 (129)i 5.60 (142)i 4.21 (107)j 3.19 (81) 3.19 (81) (1P Unit Width 0.75 (19) 5.00 (127)i 5.07 (129)i 0.71 (18) 0.71 (18) 0.71 (18) 1.42 (36) Mount) Depth 2.92 (74) 3.47 (88)i 3.60 (91)i 2.76 (70) 2.76 (70) 2.56 (65) in. (mm) Pages Pages 7-14 Pages 1-2 Pages 7-16 through 7-19 Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. a QYU is a UL 1077 supplementary protector. b C60N are recognized components per UL 1077. c For information regarding 3 corner grounded systems see the Supplemental Digest. d 1P and 2P, 1070 A and 3P 1060 A only. e QOU is UL Listed for 60 Vdc per pole 80100 A, 1P; 80125 A, 2P; and 70100 A, 3P. f HACR on QOU 1P and 3P 15100 A, 2P 15125 A; g UL 489A for DC Telecom applications (1-pole only). h Factory-installed option only i QOM1 and QOM2 dimensions are for 2-pole unit. j 480 V C60 height is 5.56 in. (141 mm). k 2 poles must be wired in series for 500 Vdc.
HACR X h Xh Xh X X h Xh Xh X X h Xh Xh X X h Xh Xh
7-3
Selection Information
100 A Frame
Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 240 Vac UL/CSA/NOM Rating (kA RMS) (50/60 Hz) 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac DC Ratings IEC Rating (kA RMS) Icu/lcsd IEC 50/60 Hz Special Ratings Fed. Specs W-C-375B/GEN HACR (2P, 3P) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications Shunt Trip Undervoltage Trip Auxiliary Switches Alarm Switch Motor Operator Handle Operators Mechanical Interlocks (3P) Handle Padlock Attachment Cylinder Lock (3Pf) Handle Mechanical Interlocks Optional GF Protectiong Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch Electronic Enclosures (Pages 7-567-58) General Purpose (NEMA 1) Raintight (NEMA 3R) Dust-tight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Dimensions (3P Unit Mount) in. (mm) Height Width Depth 250 Vdc 500 Vdca 240 Vac 415 Vac
FA 2, 3 15100 25 18 18 14 14 10 10/2.5
FH 2, 3 15100 65 25 25 18 18 50 20 10/2.5
For additional IEC ratings, see the Supplemental Digest. X X X X X X X X X X 4.72 (120) 3.54 (90) 3.94 (100) X Xh Xh Xh X X X X Xh Xh X Xh Xh Xh X X X X X X X Xh Xh Xh X X X X Xh Xh X Xh Xh Xh X X X X X X 6.4 (163) 4.1 (104) 3.4 (86) X X X X X X X X X X X X X X X Xj X X X X X X X X X X X X X X X X X X X X Xj X X X X X X X X X X X X X X X X X X X Xfe Xfe Xfe Xfe X X X X X X X X 6 (152) 4.5 (114) 4.13 (105) X X X X X Xf X X X X X X X X X X X X X Xf Xf Xf Xf X X X X X X X X X X X X X X X X X Xf X X X X X X X X 6 (152) 4.5 (114) 4.13 (105) X X X X Xf X X X X X X X X X Xf Xf Xf Xf X X X X X X X X X X X X X X
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Pages (Unit Mount)/(I-Line) Page 7-24 Pages 7-22, 7-23, 7-28, 7-33/9-25 Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. a Ungrounded UPS systems only. See page 7-34. b 65 kA @120 Vac c 1 125 Vdc rating only. d Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. e Not available on 1P FA (240 V).
Pages 7-49,/9-23 Pages 7-49/9-24 f Factory-installed option only. g Requires factory-installed G Shunt trip and 3P module. h Not available in HD and HG 2P rating (2P module). i 2P in a 3P module. j 3P only. k 1P FA is 120 Vac.
7-4
Selection Information
www.schneider-electric.us
100 A F-Frame
Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 240 Vac UL/CSA/NOM Rating (kA RMS) (50/60 Hz) 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac DC Ratings IEC Rating (kA RMS) Icu/lcsd IEC 50/60 Hz Special Ratings Fed. Specs W-C-375B/GEN HACR (2P 3P) , Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications Shunt Trip Undervoltage Trip Auxiliary Switches Alarm Switch Motor Operator Handle Operators Mechanical Interlocks (3P) Handle Padlock Attachment Cylinder Lock (3Pf) Optional GF Protectione Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (Automatic) Electronic Enclosures (Pages 7-567-58) General Purpose (NEMA 1) Raintight (NEMA 3R) Dust-tight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Dimensions (3P Unit Mount) in. (mm) Height Width Depth 250 Vdc 500 Vdcc 240 Vac 415 Vac
FY 1 1530 14 14
6/1.5 For additional IEC ratings, see the Supplemental Digest. X X X X Xf Xf Xf Xf X X X X X X X X 8 (203) 4.5 (114) 4.75 (121) X X X
X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X Xg X X X X X
X X X X X X X X X X X X X X X X X
X X X X X X X X X X
X X X X X X X X X
X X X X X X X X
Note: a b c d e f g
Pages (Unit Mount)/(I-Line) Pages 7-49/9-24 Pages 7-22, 7-23, 7-28, 7-33, 7-34/9-25 All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. 2P in a 3P module I-Line Q-frame circuit breakers are available 70225 A only. 250 A Q-frame unit-mount circuit breakers are limited to Cu conductors only. Ungrounded UPS systems only. See page 7-34. Special DC J-Frame only. Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. Requires factory-installed G shunt trip and 3P module. Factory-installed option only. 3P only.
Pages 7-24/9-24
7-5
Selection Information
250 A K-Frame
400 A L-Frame
600 A L-Frame
Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 240 Vac UL/CSA/NOM Rating (kA RMS) (50/60 Hz) 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac DC Ratings IEC 60947-2 (kA RMS) Icu/lcsb IEC 50/60 Hz Special Ratings Fed. Specs W-C-375B/GEN HACR (2P, 3P) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications Shunt Trip Undervoltage Trip Auxiliary Switches Alarm Switch Motor Operator Handle Operators Mechanical Interlocks (3P) Handle Padlock Attachment Cylinder Lock (3P) Optional GF Protection Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (Automatic) Electronic Enclosures (Pages 7-567-58) General Purpose (NEMA 1) Raintight (NEMA 3R) Dust-tight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Dimensions (3P Unit Mount) in. (mm) Height Width Depth 250 Vdc 500 Vdca 240 Vac 415 Vac
KI 2, 3 110250 200 200 200 100 100 130/65 For additional IEC ratings, see the Supplemental Digest. X X X X Xc Xc Xc Xc X X Xe X X X X 8 (203) 4.5 (114)
Q4 2,3 250400 25
LH 2, 3 125400 65 35 35 25 25 50 20 20/5
X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X Xd X X X X X X X X X
X X X X X X X X X X X
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
4.75 (121) 4.33 (110) Pages Pages (Unit Mount)/(I-Line) Pages 7-25/7-33 7-49/9-26 Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. a Ungrounded UPS systems only. See page 7-34. b Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. c Factory-installed option only. d Requires circuit breaker with WB suffix . e Requires factory-installed G Shunt trip. Available only for 3P. f 65/50 kA Icu/Ics for 450 A600 A ratings
Pages 7-51/9-27
7-6
Selection Information
www.schneider-electric.us
600 A L-Frame
1000 A M-Frame
Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 240 Vac UL/CSA/NOM Rating (kA RMS) (50/60 Hzb) 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac DC Ratings IEC (kA RMS) Icu/lcsc IEC 50/60 Hz Special Ratings Fed. Specs W-C-375B/GEN HACR (2P, 3P) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications Shunt Trip Undervoltage Trip Auxiliary Switches Alarm Switch Motor Operator Handle Operators Mechanical Interlocks (3P) Handle Padlock Attachment Cylinder Lock (3P) Optional GF Protection Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (Automatic) Electronic Enclosures (Pages 7-567-58) General Purpose (NEMA 1) Raintight (NEMA 3R) Dust-tight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Heightin. (mm) Dimensions (3P Unit Mount) Widthin. (mm) Depthin. (mm) Note: a b c d e f 250 Vdc 500 Vdca 240 Vac 415 Vac
PG 2, 3, 4
PJ 2, 3, 4
PK 2, 3, 4
PL 2, 3, 4
MA 2, 3
MH 2, 3 3001200 65 65 65 25 25 50 20 65/33
MX 3 450800 65 65 65 25 25 65/33
ME 3 450800 65 65 65 25 25 65/33
1001200 1001200 1001200 1001200 3001200 65 35 35 18 18 50/25 35/20 100 65 65 25 25 65/35 50/25 65 50 50 50 50 50/25 50/25 125 100 100 25 25 125/65 85/45 42 30 30 22 22 14 30/30
For additional IEC ratings, see the Supplemental Digest. X X X X X X X X X Xe X X X X X X X X X X X Xe X X 11.86 (301) 7.5 (190) 6.74 (171) X X X X X X X X X Xe X X X X X X X X X X X X X X X X X X 12.80 (325) 8.30 (210) 8.10 (205) X X X X X X X X X X X X X X X X X X X X Xe X X X X X Xe Xe X X X X X X X X X X X X Xe X X X X X Xe Xe X X X X X X X X X X X X X Xe X X X X X Xe Xe X X X X X X X X X X X X X Xe X X X X X Xe Xe X X X X X X X X X X X X X X X X X X X X Xd X X X X X X X X
For additional IEC ratings, see the Supplemental Digest. X X X X X X X X X X X X Xd X X X X X X X X X 14 (356) 9 (229) 6.5 (165) Supplemental Digest Section 3 X X X Xe Xe Xe Xe X X Xe X X X X X X X X Xe Xe Xe X X Xe X X X X X X X
Pages (Unit Mount)/(I-Line) Page 7-52/9-28 Page 7-25/9-28 Page 7-26, 7-30, 7-33/9-29 All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. Ungrounded UPS systems only. See page 7-34. UL PowerPact MG/MJ and PG/PJ/PK/PL are 60 Hz only. Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. Requires breaker with WB suffix Factory-installed option only. 65/50 kA Icu/Ics for 450600 A ratings.
7-7
Xe
Selection Information
1200 A N-Frame
2000 A P-Frame
2500 A P-Frame
Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 240 Vac UL/CSA/NOM Rating (kA RMS) (50/60 Hz) 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac DC Ratings IEC (kA RMS) Icu/lcsb IEC 50/60 Hz Special Ratings Fed. Specs W-C-375B/GEN HACR (2P, 3P) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications 250 Vdc 500 Vdca 240 Vac 415 Vac
PA 2, 3 6002000 65 50 50 42 42 25 50/38
PH 2, 3
PC 2, 3
PX 3
6002000 16002500 6002500 125 100 100 65 65 70/53 125 100 100 65 65 25 70/53 125 100 100 65 65 70/53
For additional IEC ratings, see the Supplemental Digest. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 15 (381) 8.07 (205) X X X X X X X X X Xc X X X X X X X X X X X X Xc X X X X X X X X X X X X 13.7 (348) 10.47 (266) X X X X X X X X X X X X X X X X X 26.1 (663) 23.3 (592) 16.55 (420) X X X X X X X X X X X X X X X X X Xc X X X 13.7 (348) 10.47 (266) X X X X X X X X Xc X X X X X X Xd X X X X X X X X X X X X Xd X X X X X X X X X 15 (381) 16.50 (420) 14.40 (366) Page 7-27, 7-33/9-30 X X X Xd X X X X X X X X X X X X Xd X X X X X X X X X
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Shunt Trip Undervoltage Trip Auxiliary Switches Alarm Switch Motor Operator Handle Operators Mechanical Interlocks (3P) Handle Padlock Attachment Cylinder Lock (3P) Optional GF Protection Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (Automatic) Electronic Enclosures (Pages 7-567-58) General Purpose (NEMA 1) Raintight (NEMA 3R) Dust-tight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Heightin. (mm) Dimensions (3P Unit Mount) Widthin. (mm) Depthin. (mm) Note: a b c d
12.12 (308)
20.06 (510)
20.06 (510)
Pages (Unit Mount)/(I-Line) Supplemental Digest Section 3 Supplemental Digest Section 3 All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. Ungrounded UPS systems only. See page 7-34. Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. Factory-installed option only. 1000 A and 1200 A only.
7-8
Selection Information
www.schneider-electric.us
Masterpact 1200 A
Masterpact 6000 A
Circuit Breaker Type Number of Poles Current Range Interrupting Ratings 240 Vac UL/CSA/NOM Rating (kA RMS) (50/60 Hz) 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac DC Ratings IECb (kA RMS) Icu/Ics Special Ratings Fed. Specs W-C-375B/GEN HACR (2P, 3P) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications Shunt Trip Undervoltage Trip Auxiliary Switches Alarm Switch Motor Operator Handle Operators Mechanical Interlocks Padlock Attachment Cylinder Lock Optional GF Protection Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (Automatic) Electronic Enclosures General Purpose (NEMA 1) Raintight (NEMA 3R) Dust-tight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Dimensions (3P Unit Mount) in. (mm) Height Width Depth 250 Vdc 500 Vdc 240 Vac 415 Vac
NT-N 3, 4 1001200 50 50 50 35 35 X X X X X X X X X X X X X
NT-H 3, 4 1001200 65 50 50 X X X X X X X X X X X X X
NW-N 3, 4 1002000 65 65 65 50 50 X X X X X X X X X X X X X
NW-L 3
NW-H 3, 4
NW-L 3
6403000 12006000 12006000 200 150 150 100 100 X X X X X X X X X X X X X 100 100 100 85 85 X X X X X X X X X X X X X 200 150 150 100 100 X X X X X X X X X X X X
17.28 (439) 17.74 (450) 18.38 (467) Page 7-45 and Catalog 0613CT0001
Pages Page 7-45 and Catalog 0613CT0001 Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. a Tested to show arc flash hazard risk category as reference by NFPA70E. b See Catalog 0613CT0001 for additional ratings and other information.
7-9
QO Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog 0730CT9801
www.schneider-electric.us
miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a The QO exclusive Qwik-Open mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15A and 20 A QO circuit breakers.
QO 1P
Table 7.1:
Amperes Rating b
Table 7.2:
Ampere Rating 1030 A 3560 A 3550 A 70110 A 60100 A
1 Space Required QO 2P
10 k AIR 10 A QO110 29.10 QO210 15 A QO115 de 29.10 QO215d 20 A QO120de 29.10 QO220d 25 A QO125d 29.10 QO225d 30 A QO130d 29.10 QO230d 35 A QO135d 29.10 QO235d 40 A QO140d 29.10 QO240d 45 A QO145d 29.10 QO245d 50 A QO150d 29.10 QO250d 60 A QO160d 29.10 QO260d 70 A QO170d 67.00 QO270d 80 A QO280d 90 A QO290d 100 A QO2100d 110 A QO2110d 125 A QO2125d 150 A QO2150dfk 175 A QO2175dfk 200 A QO2200dfk Molded Case Switch 60 A max.240 Vac Molded Case Switch 100 A max.240 Vac 22 k AIRd 15 A QO115VHe 63.00 QO215VHg 20 A QO120VHe 63.00 QO220VHg 25 A QO125VH 73.00 QO225VHg 30 A QO130VH 73.00 QO230VHg 40 A 50 A QO240VHg QO250VHg
67.00 67.00 QO215H 200.00 67.00 QO220H 200.00 67.00 QO225H 200.00 67.00 QO230H 200.00 67.00 67.00 QO240H 200.00 67.00 67.00 QO250H 200.00 67.00 QO260H 200.00 134.00 QO270H 224.00 189.00 QO280H 315.00 189.00 QO290H 315.00 189.00 QO2100H 315.00 428.00 428.00 491.00 491.00 491.00 QO200 70.00 QO2000i 200.00 146.00 146.00 146.00 146.00 146.00 146.00
Table 7.3:
Circuit Breaker Type
Wire Sizesb
Ampere Wire Size Rating (AWG/kcmil) 1030 A 148 Al/Cu QO 1030 A (2) 1410 Cu 1P 3570 A 82 Al/Cu 1030 A 148 Al/Cu 1030 A (2) 1410 Cu QO 3570 A 82 Al/Cu 2P 80125 A 42/0 Al/Cu 150200 A 4300 Al/Cu 1030 A 148 Al/Cu, (2) 14-10 Cu QO 3570 A 82 Al/Cu 3P 80125 A 42/0 Al/Cu QOB-VH 110150 A 4300 Al/Cu QOT 1520 A 128 Al 148 Cu 1530 A 128 Al 148 Cu QO-AFI, QO-GFI & QO-EPD 40, 50, 60 A 124 Al 146 Cu QO-PL 1060 A 122 Al 142 Cu
Table 7.4:
Ampere Ratingb 1P120/240 Vac 15 A & 15 A 15 A & 20 A 20 A & 20 A 2P120/240 Vac
QO340VHg 371.00 QO350VHg 371.00 QO360VHg QO370VHg QO380VHg QO390VHg QO3100VHg 371.00 477.00 530.00 530.00 530.00
4 Spaces Required QO 3P
60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A 42 k AIRd 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 65 k AIRd
QO260VHg 146.00 QO270VHg 224.00 QO280VHg 315.00 QO290VHg 315.00 QO2100VHgh 315.00 QO2110VHgh 1034.00 QO2125VHgh 1034.00 QO2150VHfgk 1061.00 QO2175VHfgk 1061.00 QO2200VHfgk 1061.00 QOH240i QOH245i QOH250i QOH260i QOH270 QOH280 QOH290 QOH2100 QOH2110i QOH2125 317.00 317.00 317.00 317.00 528.00 651.00 651.00 651.00 1389.00 1389.00
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS 3 Spaces Required
Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles.
Table 7.5:
For Use in Old Style Non-Class CTL QO Load Centers10 k AIR Ampere Ratingb Cat. No.d $ Price 1P120/240 Vac1 Space Required 15 &A 15 A QO1515 73.00 15 A & 20 A QO1520 73.00 20 A & 20 A QO2020 73.00 20 A & 30 A QO2030 73.00 30 A & 20 A QO3020 73.00 Two 1P Individual Trip120/240 Vac2 Spaces Required Order Two QO1515 or QO2020 circuit 15 A & 15 A breakers and handle tie QOTHT for 15 A & 20 A common switching of center two poles. 20 A & 20 A 20 A & 30 A QO20303020j 134.00 30 A & 20 A
a b c d e f g h i j k
15 A QH115e 117.00 QH215 293.00 QH315d 507.00 20 A QH120e 117.00 QH220 293.00 QH320 507.00 25 A QH125i 117.00 QH225i 293.00 QH325i 507.00 117.00 QH230 293.00 QH330 507.00 30 A QH130 See Digest Section 1 for load centers, and Section 9 for panelboards and interiors. 1030 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35125 A circuit breakers QOT Tandem are suitable for use with 75oC conductors. UL Listed 5 k AIR on corner grounded Delta systems. UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. Requires four spaces (1 AWG300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads. UL Listed for use ahead of QO, QO-GFI, QO-EPD, QO-AFI, QOT,QOCAFI, and QO-PL 10 k AIR circuit breakers to permit their application at 22 kA fault level. 100 A maximum branch mounted opposite. Mounting Cam Rail Bead Order only. Contact your local Field Office. Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. Pan Rail Slot Not suitable for use in 3 panels. Use only in 1 panel rated 150 A or greater. Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-12 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
Circuit limiting QOT tandem circuit breakers have a mounting cam as shown. Installation into a QO load center can only be made in those positions having a mounting pan rail slot. Meets Paragraph 408.15 of the NEC. UL Listed as Class CTL
7-10
DE2A
Discount Schedule
QO Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog 0730CT9801
QO-HID HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table 7.10: QO-HID Circuit Breakers
2P Common Trip 120/240 Vac 10 k AIR 2 Spaces Required 3P Common Trip 240 Vac 10 k AIR 3 Spaces Required
QO Arc-Fault Circuit Breaker QO arc-fault circuit breakers provide branch feeder protection for series and parallel-type arcing as required by the NEC and local code adoption, and comply with UL1699.
1P QO-AFI
Table 7.6:
Circuit Breaker Type
15 20
Cat. No. $ Price Cat. No. $ Price QO115CAFI 282.00 QO115VHCAFI 534.00 QO120CAFI 282.00 QO120VHCAFI 534.00
1P QO-GFI
2P QO-GFI
QO-GFI Qwik-Gard circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Table 7.7: QO-GFI Circuit Breakers New!
Ampere Ratingc Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 1P 120 Vac 10 k AIR 1 Space Required 22 k AIR 2P Common Trip 3P Common Trip 120/240 Vac 208Y/120 Vac 10 k AIR 10 k AIR 3 Spaces Required $ Cat. No. Price QO315GFI 791. QO320GFI 791. QO330GFI 791. QO340GFI 791. QO350GFI 791.
15 20 25 30 40 50
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price QO115HIDb 38.10 QO215HID 87.00 QO315HID 300.00 QO120HIDb 38.10 QO220HID 87.00 QO320HID 300.00 QO125HID 38.10 QO225HID 87.00 QO325HID 300.00 QO130HID 38.10 QO230HID 87.00 QO330HID 300.00 QO140HID 38.10 QO240HID 87.00 QO150HID 38.10 QO250HID 87.00
3P QO-GFI
QO-K Key operated QO circuit breakers are available in singlepole construction and can be mounted in any single-pole space which will accept a standard QO. These circuit breakers can be turned ON or OFF or to RESET with a special key (catalog number QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available as shown in the table. Table 7.11:
Ampere Rating c 10 15 20 30
1 Space Required 2 Spaces Required $ Price 413. 413. 413. 413. 413. 413. 413.
Two-wire QO-SWN
15 20 25 30 40 50 60
$ $ Cat. No. Price Cat. No. Price Cat. No. QO115GFI 233. QO115VHGFI 482. QO215GFI QO120GFI 233. QO120VHGFI 482. QO220GFI QO125GFI 233. QO125VHGFI 482. QO225GFI QO130GFI 233. QO130VHGFI 482. QO230GFI QO240GFI QO250GFI QO260GFId
Three-wire QO-SWN
QO115HMab QO120HMab
30.60 30.60
Ampere Ratingc
$ $ $ $ Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 15 QO115EPD 410. QO215EPD 660. QO315EPDe1077. QO315EPEe 1077. 20 QO120EPD 410. QO220EPD 660. QO320EPDe1077. QO320EPEe 1077. 25 QO125EPD 410. QO225EPD 660. 30 QO130EPD 410. QO230EPD 660. QO330EPDe1077. QO330EPEe 1077. 40 QO240EPD 660. QO340EPDe1077. QO340EPEe 1077. 50 QO250EPD 660. QO350EPDe1077. QO350EPEe 1077. 60 QO260EPDd 660.
QO-SWN Switch Neutral Common Trip 2008 NEC 514.11 Table 7.9:
Ampere Ratingc
10 15 20 25 30 40 50
UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. 1030 A circuit breakers are suitable for use with 60 C or 75 C conductors. 3560 A circuit breakers are suitable for use with 75 C conductors. Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. See note in Instruction Bulletin when using in an enclosure with a QO403 or QON prefix.
Interrupting Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-12 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54
DE2A
Discount Schedule
7-11
QO-EPD/EPE QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 milliampere level (EPD) or 100 milliamp level (EPE). They are not designed to protect people from electrical shock. Table 7.8: QO-EPD Circuit Breakers New!
QO-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 7.12: QO-HM Circuit Breakers
Ampere Ratingc 1P Cat. No $ Price
Handle Attachments Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P Converts any two adjacent 120/240 Vac 1P side-by-side QOT circuit breakers to independent trip 2P Handle tie and lock-off for three 1P QO, QOB circuit breakers Clamp for holding QO 1P handle in ON or OFF position Handle Clamp: Clamp for holding QO or Q1 1P, 2P or 3P circuit breaker handles in ON or OFF position For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment Fixed attachment For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position Handle Padlock Attachment: for Padlocking in ON or OFF position For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE in either ON or OFF position, fixed attachment. For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment Fixed attachment For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. Handle Padlock Attachment: for For padlocking 1P QO-GFI, QO-AFI, QO-CAFI, and QO-EPD circuit breakers in OFF position only, fixed Padlocking in OFF position attachment. For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE circuit breakers in OFF position only, fixed attachment. Ring Terminal Ring terminals are available as a factory-installed option. Sub-Feed Lugs 60 A 2P plug-on 2 spaces required (62 Al/Cu) 125 A 2P plug-on 2 spaces required (122/0 Al/Cu) 225 A 2P plug-on 4 spaces required (4300 Al/Cu) 125 A 3P plug-on 3 spaces required (122/0 Al/Cu) For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-byMechanical Interlock Attachment side so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit With Retaining Kit: breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. a Not suitable for use in 3 panels. Use only in 1 panel rated 150 A or greater. Handle Tie:
7
HLO1
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Factory-Installed Accessories for Use with QO and QOB Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on QO, QO-GFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factoryinstalled accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers or on QO2150, QO2175, or QO2200 circuit breakers. Table 7.15:
Accessory
Factory-Installed Accessories
Description Rated Voltage 12 24 120 208 240 Coil Cat. No. $ Price Contact Max. Description Burden Suffix Adder Accessory Comb. Voltage 60 VA Monitors circuit breaker contact status and -1042 189.00 provides a remote signal indicating the 168 VA circuit breaker contacts are OPEN or 72 VA CLOSED. Auxiliary 1A AC 120 228 VA -1021 189.00 Switches 1B AC 120 Application 288 VA Auxiliary switch terminals accept (2) 1412 AWG Cu leads. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normallyopen contact. Alarm 1A AC 120 Switches Application Max. Load Cat. No. Suffix $ Price Adder
Trips the circuit breaker from a remote location by means of a trip AC/DC coil energized from a separate circuit. A 120 Vac shunt trip will AC operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. Shunt Trip Application For use with momentary or maintained push button. Not available on QO-GFI, QO-EPD, QO-AFI, QOCAFI. Shunt trip terminals accept (2) 1412 AWG Cu.
5A 5A
-1200 -1201
132.00 132.00
5A
-2100
132.00
7-12
DE2A
DE2E
DE3
Discount Schedule
Table 7.16:
Voltage System
SN12125
QON2L40
QO Plug-On Mounting BasesFor unit mounting QO, QO-GFI, QO-AFI and QO-EPD circuit breakers 70 A 2 2 QON2L70 27.30 144 Cu, 123 Al 125 A 4 4 SK9948BW 75.00 121/0 Cu/Al 125 A 4 4 SK9842 78.00 121/0 Cu/Al 12W 240 Vac Max. 10 k AIC 125 A 6 6 SK9795 84.00 121/0 Cu/Al (Without Neutral Assembly) 125 A 6 6 SK9801 108.00 121/0 Cu/Al 150 A 6 6 SK9796BW 131.00 83/0 Cu/Al 150 A 8 8 SK9797 140.00 83/0 Cu/Al 40 A 2 2 QON2L40 35.00 146 Cu, 126 Al 70 A 2 4 QON24L70 50.00 144 Cu, 123 Al 100 A 6 12 QON612L100 70.00 81/0 Cu/Al 100 A 8 16 QON816L100 92.00 81/0 Cu/Al 100 A 12 12 QON12L100 113.00 122/0 Cu/Al 100 A 12 12 QON12L100SFb 161.00 62/0 Cu/Al 125 A 12 12 QON112L125I 120.00 42/0 Cu/Al 125 A 12 24 QON11224L125I 168.00 42/0 Cu/Al 125 A 16 16 QON116L125I 131.00 42/0 Cu/Al 125 A 16 24 QON11624L125I 191.00 42/0 Cu/Al 13W 240 Vac Max. 10 k AAIC 125 A 20 20 QON120L125I 225.00 42/0 Cu/Al 125 A 24 24 QON124L125I 263.00 62/0 Cu/Al 125 A 32 32 QON132L125I 360.00 42/0 Cu/Al 263.00 42/0 Cu/Al 125 A 20 24 QON12024L125I 150 A 24 24 QON124L150I 263.00 4250 Cu/Al 200 A 12 12 QON124L200I 339.00 4250 Cu/Al 200 A 12 12 QON12L200FTLc 500.00 4250 Cu/Al 200 A 24 24 QON124L200I 339.00 4250 Cu/Al 200 A 24 24 QON124L200DLd 500.00 (2) 4300 Cu/Al 200 A 30 30 QON130L200I 417.00 4250 Cu/Al 225 A 42 42 QON142L225I 599.00 4300 Cu/Al 125 A 12 12 QON312L125 251.00 42/0 Cu/Al 125 A 20 20 QON320L125 380.00 42/0 Cu/Al 125 A 24 24 QON324L125 395.00 42/0 Cu/Al 33W 240 Vac Max. 10 k AIC 200 A 18 18 QON318L200 327.00 4300 Cu/Al (Without Neutral Assy.) 200 A 24 24 QON324L200 402.00 4300 Cu/Al 200 A 30 30 QON330L200 477.00 4300 Cu/Al 225 A 42 42 QON342L225 674.00 4300 Cu/Al 60 A 3 3 QON403L60N 49.80 126 Cu/Al 125 A 12 12 QON312L125I 281.00 42/0 Cu/Al 125 A 20 20 QON320L125I a 441.00 42/0 Cu/Al 125 A 24 24 QON324L125I 461.00 42/0 Cu/Al 34W 240 Vac Max. 10 k AIC 200 A 18 18 QON318L200I 426.00 4300 Cu/Al 200 A 24 24 QON324L200I 468.00 4300 Cu/Al 200 A 30 30 QON330L200I a 528.00 4300 Cu/Al 225 A 42 42 QON342L225I 716.00 4300 Cu/Al QO Plug-On Mounting BasesFor unit mounting QO, QO-GFI and QO-EPD circuit breakers
QON120L125I
Table 7.17:
Main Lug Rating 125 A 125 A 200 A 200 A 225 A
Table 7.18:
Description
200 A
Table 7.19:
Description Main lug kit for US mounting bases, 1 lug per kit, for 6 AWG to 300 kcmil cable Terminal cover for US mounting base; provides IP20 ingress protection per IEC 60529; suitable for jumper bars or cable e DE2 Discount Schedule 2009 Schneider Electric All Rights Reserved
DE3A
DE2
Discount Schedule
7-13
70 A 1 1 QOMB1 29.60 144 Cu 122 Al 70 A 2 2 QOMB2 59.00 144 Cu 122 Al 70 A 3 3 QOMB3 87.00 144 Cu 122 Al QOB Bolt-On Mounting BasesFor unit mounting QOB, QOB-GFI, QOB-EPD circuit breakers 33W 240 Vac Max.10 k AIC 100 A 3 3 QON3B 56.00 121 Cu/Al (Without Neutral Assembly) a Also IEC rated and CE marked for IEC 60439-1. Use only Square D brand Type QOXC, QOXD, QOHX and QOE circuit breakers for 415Y/240 Vac max. systems. b Device comes with factory-installed sub-feed lugs. c Device comes with factory-installed feed-thru lugs. d Device comes with factory-installed dual-line lugs. 12W 240 Vac Max. 10 k AIC (Without Neutral Assembly)
QO and QOU Miniature QOU Miniature Circuit Breakers and QYU Supplementary Protectors Circuit Breakers Class 720 / Refer to Catalog 0730CT9801
www.schneider-electric.us
For convenient flush mount, surface mount or DIN mount (symmetrical rail 35 x 7.5 DIN/EN 50 022) Single handle with internal common trip Terminal lug wire size (1) 142 AWG Cu or Al Reversible line and load lugs Field-installable quick connectors
UL Listed 48 Vdc (5 k AIR) UL Listed as HACR Type1070 A High magnetic trip circuit breakers (QOU-HM) are recommended for applications where high initial inrush may occur and for individual dimmer applications. For DIN mounting rails, see IEC Starters and Relays, Section 18
Table 7.20:
Ampere Rating
10 k AIR 10 A QOU110 15 A QOU115 20 A QOU120 25 A QOU125 30 A QOU130 40.20 35 A QOU135 40 A QOU140 45 A QOU145 50 A QOU150 60 A QOU160 70 A QOU170 78.00 22 k AIR 15 A QOU115VH 20 A QOU120VH 25 A QOU125VH 30 A QOU130VH 35 A QOU135VH 101.00 40 A QOU140VH 45 A QOU145VH 50 A QOU150VH 60 A QOU160VH a QOU-H interrupting rating is 10 kA at 240 Vac.
168.00
87.00
171.00
285.00
363.00
426.00
189.00
Table 7.21:
Ampere Rating 15 A 20 A
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS High Ampere QOU
Table 7.22:
Ampere Rating 10 A 15 A 20 A 25 A 30 A
122.00
Flush mount, surface mount, and DIN rail mount. Internal common trip. Non-reversible line and load lugs. Terminal lug wire size (1) 12 2/0 AWG Cu or Al. UL Listed 60 Vdc per pole (5 k AIR). (Note: except switches)
UL Listed as HACR type, 80125 A. Non-automatic switches have the same physical packaging as miniature circuit breakers, but provide no overcurrent or short circuit protection. They are UL Listed per UL1087 and are CSA certified.
Table 7.23:
Ampere Rating 80 A 90 A 100 A 125 A
Table 7.24:
Ampere Rating 60 A 100 A 125 A
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-12, 7-15 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
7-14
DE2
Discount Schedule
QOU Accessories
Class 720 / Refer to Catalog 0730CT9801 Accessories for QOU Low Ampere Circuit Breakers (Except as Noted)
Description Order Qty. Cat. No. Suffix -5283 Suffix -5280 QOU1PA QOU1PL Unit $ Price Add 20% to price Add 20% to price 10.10 10.10
Table 7.25:
QOU14100JBAF
Factory-installed ring tongue terminal, 1032 screw, for 1P 2P, 3P QOU, 1060 A , Hex drive 5/32 in. wire binding screw for QOU For padlocking 1P low ampere QOU circuit breaker in OFF or ON position For padlocking 2P and 3P low ampere QOU circuit breaker in OFF or ON position For padlocking 1P low ampere QOU circuit breaker in OFF position only For padlocking 2P and 3P low ampere QOU circuit breaker in OFF position only For padlocking 2P and 3P high ampere QOU circuit breaker in OFF position only Handle lock-out, ON or OFF position 4P 100 A Jumper bar assy. w/front wiring with base, cover and screw 4P 100 A Jumper bar assy. w/right side wiring with base, cover and screw 4P 100 A Jumper bar assy. w/left side wiring with base, cover and screw 1, 4P 100 A Jumper bar base with front wiring , 1, 4P 100 A Jumper bar base with left side wiring , 1, 4P 100 A Jumper bar base with right side wiring , 4P Jumper bar cover Mounting screw for jumper bar cover 6P 150 A Jumper bar assy. w/front wiring with base, cover and screw 1, 6P 150 A Jumper bar base with front wiring , 1, 6P 150 A Jumper bar base with left side wiring , 1, 6P 150 A Jumper bar base with right side wiring , 6P jumper bar cover Vertical rainproof cover 2P and 3P QO, QOU, FA and KA Horizontal rainproof cover 2P QO, QOU, and 3P Q2, EH 1P Fingersafe cover for high ampere QOU circuit breaker 1P Fingersafe cover for low ampere QOU circuit breaker Cover plate for one 2P QOU circuit breaker Cover plate for one 3P QOU circuit breaker Cover plate for two 2P QOU circuit breakers Cover plate for three 2P QOU circuit breakers Field-installable ring tongue terminal adaptor Quick connector end connection wiring Quick connector forward or reverse wiring 1P QOU mounting foot
QOURT Field-installable Ring Tongue Terminal Connector Crimp connectors are not included with Square D brand connectors
2P QOU mounting foot 3P QOU mounting foot Tapped mounting foot for QOU, 1P and 2P 1070 A, 3P 1060 A Packaged with circuit breaker Individually packaged Bulk packed Mechanical interlock attachment: Used to interlock two circuit breakers mounted side-by-side so that only one circuit breaker can be ON at a time. A 1P or 2P circuit breaker can be mounted on the left and interlocked with a 2P or 3P circuit breaker on the right. a For use on low and high ampere QOU. b 1070 A 1P and 2P, 1060 A 3P. c DE2E Discount Schedule
1 80 1
QOUQ low ampere circuit breakers with four-point quick-connect terminals are provided with permanent factory-installed terminals which are affixed to the Load or OFF end of the circuit breaker. This special terminal will accommodate up to four 1/4-inch insulated female quick connect wire terminations. Total ampacity of these connections must not exceed the rating of the circuit breaker. Table 7.26:
Poles 1 2 3
DE2
DE2A
DE2E
Discount Schedule
7-15
For QOUQ Low Ampere Circuit Breakers with Four-Point Quick-Connect Terminals
1 1 1 40 40 40 40 40 1 40 40 40 40 1 10 1 10 1 40 1 40 1 40 1 40 1 40 1 40 1 80 1 40 1 40 1 80 1 40 1 24
QOU1PAFLAc 43.50 QOU2PAFLAc 25.80 Suffix -7100 Add 20% to price HLO1c 9.90 QOU14100JBAF 73.00 QOU14100JBAR 73.00 QOU14100JBAL 73.00 QOU14100BAFB 53.00 QOU14100BALB 53.00 QOU14100BARB 53.00 QOU14100CAB 13.20 QOU1CMSB 0.35 QOU16150JBAF 99.00 QOU16150BAFB 69.00 QOU16150BALB 69.00 QOU16150BARB 69.00 QOU16150CAB 17.10 BCVac 30.80 BCVBac 30.80 BCHac 30.80 BCHBac 30.80 QOUHFSC1 2.60 QOUHFSC1B 2.10 QOULFSC1 2.60 QOULFSC1B 2.10 QOUCP2 8.30 QOUCP2B 6.60 QOUCP3 15.80 QOUCP3B 12.80 QOUCP4 9.90 QOUCP4B 7.90 QOUCP6 15.60 QOUCP6B 12.20 QOURT 5.70 QOURTB 4.40 QOUEC 5.70 QOUECB 4.40 QOUFR 5.70 QOUFRB 4.40 QOUMF1a 0.71 QOUMF1Ba 0.54 QOUMF2a 1.40 QOUMF2Ba 1.10 QOUMF3a 2.30 QOUMF3Ba 1.70
UL 489 C60N Miniature Circuit Breakers Class 860 / Refer to Catalog 0860CT0201
www.schneider-electric.us
UL 489 Listed and CSA 22.2 No.5.1 for branch circuit protection Eliminates concerns and uncertainty of using a UL 1077 device where a UL 489 device is required Replaces fuses in low-ampere range; 17 ratings up to 35 A
Trip Curve C D Use For typical loads For high inrush Magnetic Release 710 x ampere rating (714 for DC) 1014 x ampere rating
10 k AIR (1P @ 120 Vac; 2P and 3P @ 240 Vac) 60 Vdc for 1P and 125 Vdc for 2P (on C-curve circuit breakers only, see table below) Increased installation flexibility with standard box lugs or optional ring terminals Allows easy front-mounting and rear wiring when using ring terminals A wide range of electrical and mechanical accessories Suitable for reverse feeding Trip-free mechanism Positive indication of contact disconnect
1P C60N
Table 7.27:
2P C60N
Rating (A)
3P C60N
Box Lug/Box Lug 0.5 60100 125.00 1 60101 125.00 1.5 60102 125.00 2 60103 125.00 3 60104 125.00 4 60105 125.00 5 60106 125.00 114.00 6 60107 7 60108 114.00 8 60109 114.00 10 60110 114.00 13 60111 114.00 15 60112 114.00 20 60113 114.00 25 60114 114.00 30 60115 120.00 35 60116 120.00 Ring Tongue/Ring Tongue 0.5 60200 131.00 1 60201 131.00 1.5 60202 131.00 2 60203 131.00 3 60204 131.00 4 60205 131.00 5 60206 131.00 6 60207 122.00 7 60208 122.00 8 60209 122.00 10 60210 122.00 13 60211 122.00 15 60212 122.00 20 60213 122.00 25 60214 122.00 30 60215 126.00 35 60216 126.00 a 1P dual rated 120 Vac/60 Vdc. b 2P dual rated 240 Vac/125 Vdc.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS Ring Tongue C60N Box/Ring C60N
Interrupting ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-20 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54 Mounting Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-13 DIN Mounting Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 18
7-16
DE2
Discount Schedule
UL 489 C60 480 Vac and UL489A C60N Miniature Circuit Breakers Class 860 / Refer to Catalog 0860CT0201
UL 486B Listed single-barrel lug: (2) 1810 AWG (1-25 mm2) cables, Cu only Optional ring tongue terminals A wide range of electrical and mechanical accessories Suitable for reverse feeding Trip-free mechanism Positive indication of contact disconnect
1P UL489 C60
C D
UL 489 Listed, CSA C22.2 No. 5.1; Also IEC 60947-2; CE marked 480Y/277 Vac @ 10 kA (2P and 3P), 277 Vac @ 10 kA (1P) 0.5 A through 20 A 1P, 2P, 3P, 18 mm wide per pole
Trip Curve Use For typical loads For high inrush Magnetic Release 710 x ampere rating (714 for DC) 1014 x ampere rating
Table 7.28:
Rating (A)
Cat. No. Single-Barrel Wire Lug 0.5 MGN61300 1 MGN61301 2 MGN61302 3 MGN61303 4 MGN61304 5 MGN61305 6 MGN61306 8 MGN61307 10 MGN61308 15 MGN61309 20 MGN61310 Ring Tongue Terminal 0.5 MGN61366 1 MGN61367 2 MGN61368 3 MGN61369 4 MGN61370 5 MGN61371 6 MGN61372 8 MGN61373 10 MGN61374 15 MGN61375 20 MGN61376
2P UL489 C60
3P UL489 C60
Multi 9 C60N UL 489A Listed Miniature Circuit Breakers for DC Telecommunication Applications
A limited range of C60N products are UL Listed as UL 489A circuit breakers for protection of DC telecommunications circuits .
Table 7.29:
Interrupting Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-3 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54
DE2
Discount Schedule
7-17
Multi 9 C60H-DC UL 1077 Recognized Supplementary Protectors (250 and 500 Vdc)
The C60H-DC supplementary protectors are used in direct current circuits (industrial control and automation, transport, renewable energy, etc.). They provide overcurrent protection within appliances or electrical equipment.
Table 7.30:
1P C60H-DC
Range from 0.540 A 5 k AIR at 250 Vdc (1-pole) and 5 k AIR at 500 Vdc (2-pole, wired in series) Trip-free mechanism Positive indication of contact disconnect C-Curve7 to14 times ampere rating UL 1077, IEC 60947-2, EN 60947-2, GB 14048.2, CCC and CE mark
Current Cat. No. $ Price Cat. No. $ Price (A)a 0.5 MGN61500 182.00 MGN61520 392.00 1 MGN61501 182.00 MGN61521 392.00 2 MGN61502 182.00 MGN61522 392.00 3 MGN61503 182.00 MGN61523 392.00 4 MGN61504 182.00 MGN61524 392.00 5 MGN61505 182.00 MGN61525 392.00 6 MGN61506 182.00 MGN61526 392.00 10 MGN61508 182.00 MGN61528 392.00 13 MGN61509 182.00 MGN61529 392.00 15 MGN61510 182.00 MGN61530 392.00 16 MGN61511 182.00 MGN61531 392.00 20 MGN61512 182.00 MGN61532 392.00 25 MGN61513 182.00 MGN61533 392.00 30 MGN61514 182.00 MGN61534 392.00 32 MGN61515 182.00 MGN61535 392.00 40 MGN61517 200.00 MGN61537 412.00 a At 25C/77F, for other temperatures see temperature derating table in Multi 9 Catalog 0860CT0201R1/08
2P C60H-DC
Provides ground fault protection for electrical circuits. Available in 2P (2-wire) and 4P (3- or 4-wire) versions Provides no thermal or magnetic protection. The circuit must be protected by an upstream device. Contains Si Technology to increase immunity to noise and to minimize the potential for nuisance tripping in noisy electrical environments.
Tripped condition due to a ground fault is displayed on the front face by a red mechanical indicator. DIN rail mounting for easy installation.
Table 7.31:
IEC 61008 IEC 61008 230/400 Vac, 240/415 Vac, 50 Hz 230/400 Vac, 240/415 Vac, 50 Hz Cat. No. 60969 60970 60971 60972 60973 60974 60975 60976 60977 60978 60979 $ Price 696.00 627.00 488.00 734.00 660.00 513.00 1100.00 990.00 770.00 1026.00 1206.00 Cat. No. 60989 60990 60991 60992 60993 60994 60995 60996 60997 60998 60999 $ Price 720.00 648.00 504.00 758.00 683.00 531.00 1136.00 1023.00 795.00 1272.00 1496.00
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS 2P GFP 4P GFP (3- or 4-wire)
Current Maximum (A) Sensitivity (mA) 30 25 100 300 30 40 100 300 30 63 100 300 80 300 100 300
Tripping Range 22.1 to 29.9 mA 73.1 to 98.9 mA 221 to 299 mA 22.1 to 29.9 mA 73.1 to 98.9 mA 221 to 299 mA 22.1 to 29.9 mA 73.1 to 98.9 mA 221 to 299 mA 221 to 299 mA 221 to 299 mA
Family GFP 30 GFP 100 GFP 300 GFP 30 GFP 100 GFP 300 GFP 30 GFP 100 GFP 300 GFP 300 GFP 300
Cat. No. 60949 60950 60951 60952 60953 60954 60955 60956 60957 60958 60959
$ Price 633.00 570.00 444.00 666.00 600.00 467.00 1001.00 900.00 701.00 933.00 1097.00
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-20 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
7-18
DE2
Discount Schedule
Intended for use within equipment where branch circuit protection is already provided or not needed
1P UL 1077 C60N
Range from 0.5 to 63 A 10 k AIR @ 120/240 Vac; 5 k AIR at 480Y/277; 10 k AIR @ 60 Vdc (1P) and 125 Vdc (2P) Suitable for reverse feeding DIN mounting for easy installation Suitable for reverse feeding
Table 7.32:
Rating (A)
2P UL 1077 C60N
3P UL 1077 C60N
4P UL 1077 C60N
B CurveMagnetic Setting Between 3.2 and 4.8 Times Ampere Rating 1 MG24110 101.00 MG24125 1.2 MG17402 101.00 MG17432 1.5 MG17403 101.00 MG17433 2 MG24111 101.00 MG24126 3 MG24112 101.00 MG24127 4 MG24113 101.00 MG24128 5 MG17404 101.00 MG17434 6 MG24114 101.00 MG24129 7 MG17405 101.00 MG17435 8 MG24115 101.00 MG24130 10 MG24116 101.00 MG24131 13 MG24117 101.00 MG24132 15 MG17406 101.00 MG17436 16 MG24118 101.00 MG24133 20 MG24119 101.00 MG24134 25 MG24120 101.00 MG24135 30 MG17407 101.00 MG17437 32 MG24121 101.00 MG24136 35 MG17408 101.00 MG17438 40 MG24122 111.00 MG24137 50 MG24123 117.00 MG24138 60 MG17409 123.00 MG17439 63 MG24124 123.00 MG24139 C CurveMagnetic Setting Between 7 and 10 Times Ampere Rating 0.5 MG17411 120.00 1 MG24425 101.00 MG24442 1.2 MG17412 101.00 MG17442 1.5 MG17413 101.00 MG17443 2 MG24426 101.00 MG24443 3 MG24427 101.00 MG24444 4 MG24428 101.00 MG24445 5 MG17414 101.00 MG17444 6 MG24430 101.00 MG24447 7 MG17415 101.00 MG17445 8 MG24431 101.00 MG24448 10 MG24432 101.00 MG24449 13 MG24433 101.00 MG24450 15 MG17416 101.00 MG17446 16 MG24434 101.00 MG24451 20 MG24435 101.00 MG24452 25 MG24436 101.00 MG24453 30 MG17417 101.00 MG17447 32 MG24437 101.00 MG24454 35 MG17418 101.00 MG17448 40 MG24438 111.00 MG24455 50 MG24439 117.00 MG24456 60 MG17419 123.00 MG17449 63 MG24440 123.00 MG24457 D CurveMagnetic Setting Between 10 and 14 Times Ampere Rating 0.5 MG17421 120.00 1 MG24500 101.00 MG24516 1.2 MG17422 101.00 MG17452 1.5 MG17423 101.00 MG17453 2 MG24501 101.00 MG24517 3 MG24502 101.00 MG24518 4 MG24503 101.00 MG24519 5 MG17424 101.00 MG17454 6 MG24504 101.00 MG24520 7 MG17425 101.00 MG17455 8 MG24505 101.00 MG24521 10 MG24506 101.00 MG24522 13 MG24507 101.00 MG24523 15 MG17426 101.00 MG17456 16 MG24508 101.00 MG24524 20 MG24509 101.00 MG24525 25 MG24510 101.00 MG24526 30 MG17427 101.00 MG17457 32 MG24511 101.00 MG24527 35 MG17428 101.00 MG17458 40 MG24512 111.00 MG24528 50 MG24513 117.00 MG24529 60 MG17429 123.00 MG17459 63 MG24514 123.00 MG24530 Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-20 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
DE2
Discount Schedule
7-19
C60 Accessories
Class 860 / Refer to Catalog 0860CT0201
www.schneider-electric.us
Table 7.33:
C60N Padlock Attachment Heavy-duty Padlock Attachment
Descriptions OF Auxiliary Switch (1a1b) SD Alarm Switch (1a1b) MX Shunt Trip + OF Auxiliary Switch (1a1b)
Rotary Handle
Vdc Cat. No. 12125 1 MG26925 12125 1 MG26928 24 2 27118 48 2 27110 125 2 27109 24 2 27108 48 2 27106 2 27107 2 27105 120 to 480Y/277 Vac; 30, 100, and 300 mA; 2P and 4Ps. See page 7-18 Handout, 0860HO0602 or Catalog 0860CT0201
201.00
Table 7.34:
Label Holders for 2, 3 or 4P C60N
Front Mounting Kit for C60 1P, 2P, 3P, 4P (1 per circuit breaker)
Ring tongue terminal kit for UL1077 C60N Spacer for DIN rail, Not UL Recognized Padlock Attachment (1 per for 1P 2P, 3P or 4P) , Heavy-duty Padlock Attachment for C60N, Locks OFF only Padlocking Device Left Side Mount, Locks OFF onlya Padlocking Device Right Side Mount, Locks OFF onlyb Front Mounting Kit Label holders for 2, 3 or 4P C60 (Not UL Recognized) Terminal Screw Shield (Not UL Recognized)
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
New!
MGN26380 Locking Device Left Side Mount MGN26381 Locking Device Right Side Mount
Comb Bus Bar Kit for UL1077 C60, 12 poles, Fixed Length Tooth Caps for UL Comb Bus Bar, Bag of 20 Rotary Handle for C60 (Non UL Recognized) Operating Subassembly Door Interlock Handle Fixed Handle (Front or Lateral) Multi-pole Front Mounting Kit Rail Support (20 of 9 mm modules) Hinged Transparent Cover a b
MG26975 26.10 MG26976 51.00 MG26975+MG26976 MG26978 102.00 MG10285 63.00 MG10286 69.00 MG10287 80.00 60488 37.80 MG27046 MG27047 MG27048 14211 14210 129.00 107.00 117.00 54.00 158.00
2P/3P/4P
Left-side mounted padlocking device cannot be used in conjunction with accessories SD, OF, MX or MN. Use rightside mounted padlocking device when accessories are required. Right-side mounted padlocking device cannot be used in conjunction with VIGI module. Use left-side mounted padlocking device when VIGI Module is required..
7-20
DE2
Discount Schedule
PowerPact Family
Class 611
The PowerPact Advantage Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial
G-Frame 100 A H-Frame 150 A
applications. Flexible: Full range of molded case circuit breakers from 15 A to 3000 A, delivering the ratings, configurations, and operators for your unique applications. Simple: Common catalog numbers, standardized ratings, and a full range of field-installable accessories make product selection, installation and maintenance easier than ever. Common Design Features: Mounting holes, door trim, and handle accessories
J-Frame 250 A Q-Frame 250 A D-Frame 600 A M-Frame 800 A P-Frame 1200 A R-Frame 3000 A
Table 7.35:
Voltage
D 240 Vac 25 kA 480 Vac 18 kA 600 Vac 14 kA P-frame K interrupting is 50 kA at 480 and 600 Vac.
Table 7.36:
Rating Frame
B D G J K L
600 Vac 14 kA 18 kA 25 kA 65 kA 50 kA
For amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = 1200 A.
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-22 H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23 G- and Q-Frame Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24 D- and M-Frame Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25 P-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26 R-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 PowerPact H- and J-Frame Electronic Motor Circuit Protectors . . . . . . 7-28 Mag-Gard Motor Circuit Protectors (MCP). . . . . . . . . . . . . . . . . . . . . . . 7-30 Automatic Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33 500 Vdc Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-34 Mission Critical Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-35 PowerPact Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 7-36 Motor Operators and Rotary Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37 Locks, Installation Accessories, and Rear Connections . . . . . . . . . . . . . 7-38 Mechanical Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-38 Compression Lugs and Power Distribution Connectors (PDC). . . . . . . . 7-40 Terminal Nuts, Terminal Pads, Terminal Shields and Accessories . . . . . 7-41 Plug-In and Drawout Mountings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-42 Micrologic Electronic Trip Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-43 Micrologic Trip Unit Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-44
7-21
Frame Designation G 100A Frame H 150 A Frame J 250 A Frame Q 250 A Frame D 600 A Frame M 800 A Frame P 1200 A Frame R 3000 A Frame
Interrupting Rating
H-Frame 150 A and J-Frame 250 A Thermal-Magnetic UL Current-Limitinge Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unit Suitable for Reverse Connectiona
Interrupting Rating (2nd Letter of Catalog Number) Cat. No.bc D G $ Price 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1274.00 1274.00 1274.00 1274.00 2486.00 2486.00 2486.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1497.00 1497.00 1497.00 1497.00 3059.00 3059.00 3059.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1797.00 1797.00 1797.00 1797.00 3671.00 3671.00 3671.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1721.00 1721.00 1721.00 1721.00 4449.00 4449.00 4449.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 2066.00 2066.00 2066.00 2066.00 5339.00 5339.00 5339.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2613.00 2613.00 2613.00 2613.00 5534.00 5534.00 5534.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 3149.00 3149.00 3149.00 3149.00 6749.00 6749.00 6749.00 Le Terminal Wire Range 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 3137.00 3137.00 3137.00 3137.00 6641.00 6641.00 6641.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3779.00 3779.00 3779.00 3779.00 8099.00 8099.00 8099.00 Je Le Terminal Wire Range
H-Frame, 150A 2P, 600 Vac 50/60 Hz, 250 Vdc 15 A 350 A 750 A H( )L26015(C) 870.00 20 A 350 A 750 A H( )L26020(C) 870.00 25 A 350 A 750 A H( )L26025(C) 870.00 30 A 350 A 750 A H( )L26030(C) 870.00 35 A 400 A 850 A H( )L26035(C) 870.00 40 A 400 A 850 A H( )L26040(C) 870.00 45 A 400 A 850 A H( )L26045(C) 870.00 50 A 400 A 850 A H( )L26050(C) 870.00 60 A 800 A 1450 A H( )L26060(C) 870.00 70 A 800 A 1450 A H( )L26070(C) 1062.00 80 A 800 A 1450 A H( )L26080(C) 1062.00 90 A 800 A 1450 A H( )L26090(C) 1062.00 100 A 900 A 1700 A H( )L26100(C) 1062.00 110 A 900 A 1700 A H( )L26110(C) 2072.00 125 A 900 A 1700 A H( )L26125(C) 2072.00 150 A 900 A 1700 A H( )L26150(C) 2072.00 H-Frame 150A 3P, 600 Vac 50/60 Hz, 250 Vdc 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A Current Rating @ 40oC 350 A 350 A 350 A 350 A 400 A 400 A 400 A 400 A 800 A 800 A 800 A 800 A 900 A 900 A 900 A 900 A 750 A 750 A 750 A 750 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1450 A 1700 A 1700 A 1700 A 1700 A H( )L36015(C) H( )L36020(C) H( )L36025(C) H( )L36030(C) H( )L36035(C) H( )L36040(C) H( )L36045(C) H( )L36050(C) H( )L36060(C) H( )L36070(C) H( )L36080(C) H( )L36090(C) H( )L36100(C) H( )L36110(C) H( )L36125(C) H( )L36150(C) 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1328.00 1328.00 1328.00 1328.00 2600.00 2600.00 2600.00 D
H-Frame
1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1592.00 1701.00 2042.00 2099.00 2519.00 1592.00 1701.00 2042.00 2099.00 2519.00 1592.00 1701.00 2042.00 2099.00 2519.00 1592.00 1701.00 2042.00 2099.00 2519.00 3120.00 3599.00 4319.00 5174.00 6209.00 3120.00 3599.00 4319.00 5174.00 6209.00 3120.00 3599.00 4319.00 5174.00 6209.00 Interrupting Rating (2nd Letter of Catalog Number) G $ Price Je
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS J-Frame
Cat. No.bc
80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 6972.00 AL175JD 6972.00 44/0 AWG Al or Cu 6972.00 AL250JD 6972.00 3/0 AWG350 kcmil Al or Cu 8633.00 8504.00 AL175JD 8504.00 44/0 AWG Al or Cu 8504.00 AL250JD 8504.00 3/0 AWG350 kcmil Al or Cu 10791.00
J-Frame 250A 2P, 600 Vac 50/60 Hz, 250 Vdc 150 A 750 A 1500 A J( )L26150(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 175 A 875 A 1750 A J( )L26175(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 200 A 1000 A 2000 A J( )L26200(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 225 A 1125 A 2250 A J( )L26225(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 250 A 1250 A 2500 A J( )L26250(C) 2988.00 3585.00 4251.00 5102.00 6225.00 7469.00 7194.00 J-Frame 250A 3P, 600 Vac 50/60 Hz, 250 Vdc 150 A 750 A 1500 A J( )L36150(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 175 A 875 A 1750 A J( )L36175(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 200 A 1000 A 2000 A J( )L36200(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 225 A 1125 A 2250 A J( )L36225(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 250 A 1250 A 2500 A J( )L36250(C) 3749.00 4499.00 5001.00 6002.00 7238.00 8685.00 8993.00 a See page 7-23 for circuit breakers with field interchangeable trip units. b To complete catalog number, replace the blank with the appropriate rating (D, G, J, L). c For 100% rated circuit breakers add a C in the 9th character place (for example, HDL26015C or JDL26150C). d 100% rated J frame breakers have copper lugs and can only be used with copper wire. e J and L interrupts are UL certified as current limiting.
Table 7.38:
Termination Letter For factory-installed A - I-Line (See Section 9) termination, place termination F = No Lugs (includes terminal nut kit on both ends)f letter in the third block of the L = Lugs both ends circuit breaker catalog number. M = Lugs ON end Terminal Nut Kit OFF end HGL36100 P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in g Termination Letter D = Drawout g Plug-in Drawout Rear Connected S = Rear Connected g f Add TS suffix for circuit breaker without terminal nut kit. g For N and D pricing, add termination pricing on page 7-42 to price. For S pricing, add termination pricing on page 7-38 to price.
Table 7.39:
Voltage 240 Vac 480 Vac 600 Vac
7-22
DE2
Table 7.40:
H-Frame 150 A UL Current-Limitingc Circuit Breaker Frame with Field-Interchangeable Thermal-Magnetic Trip Unitsa (600 Vac, 250 Vdc)
Fixed AC Magnetic Trip Trip 750 A 750 A 750 A 750 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1450 A 1700 A 1700 A 1700 A 1700 A D Interrupting Cat. No. HDL36015T HDL36020T HDL36025T HDL36030T HDL36035T HDL36040T HDL36045T HDL36050T HDL36060T HDL36070T HDL36080T HDL36090T HDL36100T HDL36110T HDL36125T HDL36150T $ Price 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1328.00 1328.00 1328.00 1328.00 2600.00 2600.00 2600.00 G Interrupting Cat. No. HGL36015T HGL36020T HGL36025T HGL36030T HGL36035T HGL36040T HGL36045T HGL36050T HGL36060T HGL36070T HGL36080T HGL36090T HGL36100T HGL36110T HGL36125T HGL36150T $ Price 1493.00 1493.00 1493.00 1493.00 1493.00 1493.00 1493.00 1493.00 1493.00 1701.00 1701.00 1701.00 1701.00 3599.00 3599.00 3599.00 Jc Interrupting Cat. No. HJL36015T HJL36020T HJL36025T HJL36030T HJL36035T HJL36040T HJL36045T HJL36050T HJL36060T HJL36070T HJL36080T HJL36090T HJL36100T HJL36110T HJL36125T HJL36150T $ Price 1949.00 1949.00 1949.00 1949.00 1949.00 1949.00 1949.00 1949.00 1949.00 2099.00 2099.00 2099.00 2099.00 5174.00 5174.00 5174.00 Lc Interrupting Cat. No. HLL36015T HLL36020T HLL36025T HLL36030T HLL36035T HLL36040T HLL36045T HLL36050T HLL36060T HLL36070T HLL36080T HLL36090T HLL36100T HLL36110T HLL36125T HLL36150T $ Price 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 3149.00 3149.00 3149.00 3149.00 6749.00 6749.00 6749.00 Terminal Wire Range
Hold 3P, 600 Vac 50/60 Hz 15 A 350 A 20 A 350 A 25 A 350 A 30 A 350 A 35 A 400 A 40 A 400 A 45 A 400 A 50 A 400 A 60 A 800 A 70 A 800 A 80 A 800 A 90 A 800 A 100 A 900 A 110 A 900 A 125 A 900 A 150 A 900 A
Ampere Rating
Table 7.41:
J-Frame 250 A UL Current-Limitingc Circuit Breaker Frame with Field-Interchangeable Thermal-Magnetic Trip Unitsa (600 Vac, 250 Vdc)
D Interrupting G Interrupting Jc Interrupting Lc Interrupting Terminal Wire Range Low High Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 3P, 600 Vac 50/60 Hz 150 A 750 A 1500 A JDL36150T 2730.00 JGL36150T 3779.00 JJL36150T 5432.00 JLL36150T 7086.00 AL175JD 175 A 875 A 1750 A JDL36175T 2730.00 JGL36175T 3779.00 JJL36175T 5432.00 JLL36175T 7086.00 4--4/0 AWG Al or Cu 200 A 1000 A 2000 A JDL36200T 2730.00 JGL36200T 3779.00 JJL36200T 5432.00 JLL36200T 7086.00 AL250JD 225 A 1125 A 2250 A JDL36225T 2730.00 JGL36225T 3779.00 JJL36225T 5432.00 JLL36225T 7086.00 3/0 AWG350 kcmil Al or Cu 250 A 1250 A 2500 A JDL36250T 3749.00 JGL36250T 5001.00 JJL36250T 7238.00 JLL36250T 8993.00 a Circuit breakers will be labeled with Line and Load markings and are not suitable for reverse connections. Only available on standard (80%) rated 3P unit-mount circuit breakers; not available with I-Line or Plug-In constructions. Ampere Rating
Table 7.42:
Circuit Breaker Frame
H-Frame 150A and J-Frame 250 A 3P Basic UL Current-Limitingc Circuit Breaker Frame Without Terminationsb or Trip Unit (600 Vac, 250 Vdc)
Ampere Rating D Interrupting G Interrupting Cat. No. HGF36000F06 HGF36000F15 JGF36000F25 $ Price 930.00 1574.00 2790.00 Jc Interrupting Cat. No. HJF36000F06 HJF36000F15 JJF36000F25 $ Price 1386.00 3149.00 5027.00 Lc Interrupting Cat. No. HLF36000F06 HLF36000F15 JLF36000F25 $ Price 2286.00 4724.00 6782.00
Table 7.43:
Amperage 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A
H-Frame
Trip Unit
Table 7.45:
Termination Letter For factory-installed A - I-Line (See Section 9) termination, place termination F = No Lugs (includes terminal nut kit on both ends)d letter in the third block of the L = Lugs both ends circuit breaker catalog number. M = Lugs ON end Terminal Nut Kit OFF end HDL36015T P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in e Termination Letter D = Drawout e S = Rear Connected e d Add TS suffix for circuit breaker without terminal nut kit. e For N and D pricing, add termination pricing on page 7-42 to price. For S pricing, add termination pricing on page 7-38 to price. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-36 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-39 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-55 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-56 2009 Schneider Electric All Rights Reserved
DE2
Discount Schedule
7-23
Table 7.44:
Cat. No. $ Price 1560 A HDF36000F06 525.00 H-Frame 70150 A HDF36000F15 585.00 J-Frame 150250 A JDF36000F25 1538.00 b See page 7-39 for lug and termination kits. c J and L interrupts are UL Certified as current limiting.
QBL 2P 70250 A
2P, 240 Vac 70 A 1000 A 1800 A QBL22070 474.00 QDL22070 1143.00 QGL22070 1521.00 QJL22070 80 A 1000 A 1800 A QBL22080 474.00 QDL22080 1143.00 QGL22080 1521.00 QJL22080 90 A 1000 A 1800 A QBL22090 474.00 QDL22090 1143.00 QGL22090 1521.00 QJL22090 100 A 1200 A 2400 A QBL22100 474.00 QDL22100 1143.00 QGL22100 1521.00 QJL22100 110 A 1200 A 2400 A QBL22110 474.00 QDL22110 1143.00 QGL22110 1521.00 QJL22110 125 A 1200 A 2400 A QBL22125 474.00 QDL22125 1143.00 QGL22125 1521.00 QJL22125 150 A 1200 A 2400 A QBL22150 474.00 QDL22150 1143.00 QGL22150 1521.00 QJL22150 175 A 1200 A 2400 A QBL22175 474.00 QDL22175 1143.00 QGL22175 1521.00 QJL22175 200 A 1200 A 2400 A QBL22200 474.00 QDL22200 1143.00 QGL22200 1521.00 QJL22200 225 A 1200 A 2400 A QBL22225 474.00 QDL22225 1143.00 QGL22225 1521.00 QJL22225 250 A 1200 A 2400 A QBL22250b 693.00 QDL22250b 1544.00 QGL22250b 1970.00 QJL22250b 3P, 240 Vac 70 A 1000 A 1800 A QBL32070 1248.00 QDL32070 1784.00 QGL32070 2442.00 QJL32070 80 A 1000 A 1800 A QBL32080 1248.00 QDL32080 1784.00 QGL32080 2442.00 QJL32080 90 A 1000 A 1800 A QBL32090 1248.00 QDL32090 1784.00 QGL32090 2442.00 QJL32090 100 A 1200 A 2400 A QBL32100 1248.00 QDL32100 1784.00 QGL32100 2442.00 QJL32100 110 A 1200 A 2400 A QBL32110 1248.00 QDL32110 1784.00 QGL32110 2442.00 QJL32110 125 A 1200 A 2400 A QBL32125 1248.00 QDL32125 1784.00 QGL32125 2442.00 QJL32125 150 A 1200 A 2400 A QBL32150 1248.00 QDL32150 1784.00 QGL32150 2442.00 QJL32150 175 A 1200 A 2400 A QBL32175 1248.00 QDL32175 1784.00 QGL32175 2442.00 QJL32175 200 A 1200 A 2400 A QBL32200 1248.00 QDL32200 1784.00 QGL32200 2442.00 QJL32200 225 A 1200 A 2400 A QBL32225 1248.00 QDL32225 1784.00 QGL32225 2442.00 QJL32225 250 A 1200 A 2400 A QBL32250b 1812.00 QDL32250b 2442.00 QGL32250b 3150.00 QJL32250b a Replacement lugs and electrical accessories are not available for PowerPact Q-frame circuit breakers. b 250 A lugs are suitable for copper conductors only c DE2A Discount Schedule
1890.00 1890.00 1890.00 1890.00 1890.00 1890.00 #4 AWG - 300 kcmil Al/Cu 1890.00 1890.00 1890.00 1890.00 2348.00 2796.00 2796.00 2796.00 2796.00 2796.00 2796.00 #4 AWG - 300 kcmil Al/Cu 2796.00 2796.00 2796.00 2796.00 3465.00
Table 7.47:
QBL 3P 70250 A
Termination Letter For factory-installed termination, place A = I-Line (See Section 9) termination letter in the third block of the E = Bolt-on I-Line (See Section 9) circuit breaker catalog number. F = No Lugs (includes terminal nut kit on both ends)d QGL32200 L = Lugs both ends M = Lugs ON end, Studs on OFF end Termination Letter P = Lugs OFF end, Studs on ON end d Add TS suffix for circuit breakers without terminal nut kit. See Catalog 0734CT0201 for additional information.
Table 7.48:
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
B D G 240 Vace 10 kA 25 kA 65 kA e Q-frame circuit breakers are 240 Vac only. f 3P QJ circuit breakers are rated at 208Y/120 Vac only.
Voltage
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-36 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-39 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-55 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56
7-24
DE2
DE2A
Discount Schedule
Table 7.49:
Electronic Trip Unit Type
D-Frame (600 A 600 Vac) 3P 50/60 Hz Circuit Breaker with Lugs and Electronic Trip Unitsc
Trip Function Trip Unit Continuous Currenta 150 A 250 A 400 A 600 A 150 A 250 A 400 A 600 A 150 A 250 A 400 A 600 A 150 A 250 A 400 A 600 A 150 A 250 A 400 A 600 A a b c G Interrupting Cat. No. DGL36150E20 DGL36250E20 DGL36400E20 DGL36600E20 DGL36150E53 DGL36250E53 DGL36400E53 DGL36600E53 DGL36150E54 DGL36250E54 DGL36400E54 DGL36600E54 DGL36150E58 DGL36250E58 DGL36400E58 DGL36600E58 DGL36150E59 DGL36250E59 DGL36400E59 DGL36600E59 $ Price 5081.00 5081.00 5081.00 8315.00 6200.00 6200.00 6200.00 9429.00 7527.00 7527.00 7527.00 10761.00 7661.00 7661.00 7661.00 10895.00 8990.00 8990.00 8990.00 9434.00 J Interrupting Cat. No. DJL36150E20 DJL36250E20 DJL36400E20 DJL36600E20 DJL36150E53 DJL36250E53 DJL36400E53 DJL36600E53 DJL36150E54 DJL36250E54 DJL36400E54 DJL36600E54 DJL36150E58 DJL36250E58 DJL36400E58 DJL36600E58 DJL36150E59 DJL36250E59 DJL36400E59 DJL36600E59 $ Price 8478.00 8478.00 8478.00 11712.00 9597.00 9597.00 9597.00 12813.00 10925.00 10925.00 10925.00 14159.00 11058.00 11058.00 11058.00 14292.00 12387.00 12387.00 12387.00 15621.00 L Interrupting Cat. No. DLL36150E20 DLL36250E20 DLL36400E20 DLL36600E20 DLL36150E53 DLL36250E53 DLL36400E53 DLL36600E53 DLL36150E54 DLL36250E54 DLL36400E54 DLL36600E54 DLL36150E58 DLL36250E58 DLL36400E58 DLL36600E58 DLL36150E59 DLL36250E59 DLL36400E59 DLL36600E59 $ Price 9918.00 9918.00 9918.00 13152.00 11037.00 11037.00 11037.00 14721.00 12365.00 12365.00 12365.00 15599.00 12498.00 12498.00 12498.00 15732.00 13827.00 13827.00 13827.00 17061.00 Terminal Wire Range (AWG/kcmil)
LS
STR23SP
(1) 2600 Cu or (1) 2500 Al (2) 2/0350 Cu or (2) 2/0500 Al (1) 2600 Cu or (1) 2500 Al (2) 2/0350 Cu or (2) 2/0500 Al (1) 2600 Cu or (1) 2500 Al (2) 2/0350 Cu or (2) 2/0500 Al (1) 2600 Cu or (1) 2500 Al (2) 2/0350 Cu or (2) 2/0500 Al (1) 2600 Cu or (1) 2500 Al (2) 2/0350 Cu or (2) 2/0 500 Al
Standard
LSI
SR53UP-Fb
LSIG
STR53UP-FTb
STR53UP-FIb
STR53UP-FTIb
D-frame circuit breakers 400 A and below are 100% rated. 600 A is standard (80%) rated only. F = Fault indicator; T = Residual-type ground-fault protection; I = Ammeter Available with lugs (L) or bus (F) connections only.
Table 7.50:
Ampere Rating
D-Frame 3P 600 A Circuit Breaker, Frame Only, and Field-Installable Trip Units
Basic Frame Only (600 Vac)d G Interrupting J Interrupting $ Price 6164.00 6164.00 6164.00 9302.00 L Interrupting Cat. No. DLL36150F40 DLL36250F60 DLL36400F40 DLL36600F60 $ Price 7602.00 7602.00 7602.00 10740.00 Field Installable D-Frame Electronic Trip Unit Long-time, Short-time and Instantaneous Protection Description STR23SP STR53UP-F STR53UP-FT STR53UP-FI STR53UP-FTI Factory Code E20 E53 E54 E58 E59 Trip Function LS LSI LSIG LSI LSIG Cat. No. 36940 36942 36943 36944 36945 $ Price 2033.00 3152.00 4479.00 4613.00 5942.00
Cat. No. $ Price Cat. No. 150 A DGL36150F40 2766.00 DJL36150F40 250 A DGL36250F40 2766.00 DJL36250F40 400 A DGL36400F40 2766.00 DJL36400F40 600 A DGL36600F60 5904.00 DJL36600F60 d Available with lugs (L) or bus (F) connections only.
Table 7.51:
Electronic Trip Unit Type
M-Frame 800 A, Basic Electronic Trip System Type ET 1.0e Factory-Sealed Trip Unit
Trip Function Sensor Rating G Interrupting Cat. No. MGL26300 MGL26350 MGL26400 MGL26450 MGL26500 MGL26600 MGL26700 MGL26800 $ Price 5960.00 5960.00 5960.00 5960.00 5960.00 5960.00 7719.00 7719.00 J Interrupting Cat. No. MJL26300 MJL26350 MJL26400 MJL26450 MJL26500 MJL26600 MJL26700 MJL26800 $ Price 7829.00 7829.00 7829.00 7829.00 7829.00 7829.00 9657.00 9657.00 Terminal Wire Range (AWG/kcmil)
Basic
3P, 600 Vac 50/60 Hz 300 A MGL36300 7560.00 MJL36300 9456.00 350 A MGL36350 7560.00 MJL36350 9456.00 Fixed 400 A MGL36400 7560.00 MJL36400 9456.00 Long-time, 450 A MGL36450 7560.00 MJL36450 9456.00 (3) 3/0500 Basic Adjustable Al/Cu 500 A MGL36500 7560.00 MJL36500 9456.00 Instantaneous Trip 600 A MGL36600 7560.00 MJL36600 9456.00 11882.00 700 A MGL36700 9927.00 MJL36700 800 A MGL36800 9927.00 MJL36800 11882.00 The ET 1.0 trip unit cannot be field replaced or have the long-time trip point setting adjusted. It is considered an electronic equivalent of a thermal-magnetic circuit breaker.
Table 7.52:
Frame
Termination Options
Termination Option No Lugs (Includes terminal nut kit on both ends) Lugs both ends Lugs ON end Terminal Nut Kit Off end Lugs OFF end Terminal Nut Kit On end Plug-in Drawout Rear Connected No Lugs Lugs both ends Lugs ON end Terminal Nut Kit Off end Lugs OFF end Terminal Nut Kit On end
Table 7.53:
Voltage
M-Frame
Termination Letter F L M P Nf Df Sf F L M P
G J 240 Vac 65 kA 100 kA 480 Vac 35 kA 65 kA 600 Vac 18 kA 25 kA L interrupting rating is not available in M-frame.
For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number.
M G L 3 6 4 0 0 or D G L 3 6 4 0 0 E 2 0
Termination Letter
f 2009 Schneider Electric All Rights Reserved For N, D, and S pricing, add termination pricing to price. See page 7-42. Discount Schedule
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-36 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-39 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-55 Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-56
DE2
7-25
P-Frame 1200 A (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit
$ Price Sensor Rating Code Cat. No.bc G Interruptingb 80% Rated 100% Ratedc J Interruptingb 80% Rated 100% Ratedc K Interruptingb 80% Rated 100% Rated c L Interruptingbd 80% Rated 100% Ratedc Terminal Wire Range
600 A P( )L36060 (3) 3/0 AWG500 kcmil Basic Electronic Fixed long-time, 13905.00 14783.00 14783.00 15660.00 Al or Cu 800 A P( )L36080 Trip Unit Adjustable ET1.0I (Not 1000 A P( )L36100 (4) 3/0 AWG500 kcmil Instantaneous 19049.00 20250.00 20250.00 21452.00 Interchangeable) Al or Cu 1200 A P( )L36120 250 A P( )L36025(C)U31A 400 A P( )L36040(C)U31A 14693.00 21510.00 15570.00 22868.00 15570.00 22868.00 16448.00 24224.00 (3) 3/0 AWG500 kcmil Al or Cu 600 A P( )L36060(C)U31A LI 3.0 800 A P( )L36080(C)U31A 1000 A P( )L36100(C)U31A Micrologic 19836.00 30239.00 21038.00 32147.00 21038.00 32147.00 22239.00 34052.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U31A Interchangeable Standard 250 A P( )L36025(C)U33A Trip Unit 400 A P( )L36040(C)U33A 15032.00 21812.00 15909.00 23187.00 15909.00 23187.00 16787.00 24564.00 (3) 3/0 AWG500 kcmil Al or Cu 600 A P( )L36060(C)U33A LSI 5.0 800 A P( )L36080(C)U33A 1000 A P( )L36100(C)U33A 20177.00 30540.00 21378.00 32466.00 21378.00 32466.00 22580.00 34392.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U33A 250 A P( )L36025(C)U41A 400 A P( )L36040(C)U41A 15543.00 22266.00 16421.00 23670.00 16421.00 23670.00 17298.00 25076.00 (3) 3/0 AWG500 kcmil Al/Cu 600 A P( )L36060(C)U41A LI 3.0A 800 A P( )L36080(C)U41A 1000 A P( )L36100(C)U41A 20688.00 30995.00 21890.00 32949.00 21890.00 32949.00 23091.00 34904.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U41A 250 A P( )L36025(C)U43A 400 A P( )L36040(C)U43A Micrologic 17043.00 23597.00 17921.00 25085.00 17921.00 25085.00 18798.00 26574.00 (3) 3/0 AWG500 kcmil Al or Cu 600 A P( )L36060(C)U43A Interchangeable LSI 5.0A Ammeter 800 A P( )L36080(C)U43A Trip Unit 1000 A P( )L36100(C)U43A 22185.00 32324.00 23387.00 34364.00 23387.00 34364.00 24590.00 36402.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U43A 250 A P( )L36025(C)U44A 400 A P( )L36040(C)U44A 18909.00 25256.00 19787.00 26849.00 19787.00 26849.00 20664.00 28442.00 (3) 3/0 AWG500 kcmil A or Cu 600 A P( )L36060(C)U44A LSIG 6.0A 800 A P( )L36080(C)U44A 1000 A P( )L36100(C)U44A 24054.00 33983.00 25256.00 36128.00 25256.00 36128.00 26457.00 38270.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U44A 250 A P( )L36025(C)U63AE1 400 A P( )L36040(C)U63AE1 21455.00 27516.00 22332.00 29252.00 22332.00 29252.00 23210.00 30986.00 (3) 3/0 AWG500 kcmil A or Cu 600 A P( )L36060(C)U63AE1 LSI 5.0P 800 A P( )L36080(C)U63AE1 1000 A P( )L36100(C)U63AE1 Micrologic 26597.00 36243.00 27800.00 38529.00 27800.00 38529.00 29001.00 40814.00 (4) 3/0 AWG500 kcmil A or Cu 1200 A P( )L36120(C)U63AE1 Interchangeable Power 250 A P( )L36025(C)U64AE1 Trip Unit 400 A P( )L36040(C)U64AE1 22536.00 28476.00 23414.00 30272.00 23414.00 30272.00 24291.00 32067.00 (3) 3/0 AWG500 kcmil A or Cu 600 A P( )L36060(C)U64AE1 LSIG 6.0P 800 A P( )L36080(C)U64AE1 1000 A P( )L36100(C)U64AE1 27680.00 37203.00 28881.00 39551.00 28881.00 39551.00 30083.00 41895.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U64AE1 250 A P( )L36025(C)U73AE1 400 A P( )L36040(C)U73AE1 25538.00 31140.00 26415.00 33104.00 26415.00 33104.00 27291.00 35067.00 (3) 3/0 AWG500 kcmil Al or Cu 600 A P( )L36060(C)U73AE1 LSI 5.0H 800 A P( )L36080(C)U73AE1 1000 A P( )L36100(C)U73AE1 Micrologic 30680.00 39867.00 31881.00 42381.00 31881.00 42381.00 33083.00 44895.00 (4) 3/0 AWG500 kcmil Al or Cu 1200 A P( )L36120(C)U73AE1 Interchangeable Harmonic 250 A P( )L36025(C)U74AE1 Trip Unit 400 A P( )L36040(C)U74AE1 26619.00 32100.00 27497.00 34125.00 27497.00 34125.00 28374.00 36150.00 (3) 3/0 AWG500 kcmil Al or Cu 600 A P( )L36060(C)U74AE1 LSIG 6.0H 800 A P( )L36080(C)U74AE1 1000 A P( )L36100(C)U74AE1 31761.00 40829.00 32963.00 43404.00 32963.00 43404.00 34166.00 45978.00 (4) 3/0 AWG500 kcmil A or Cu 1200 A P( )L36120(C)U74AE1 a For 2P and 4P information see Catalog 0612CT0101. b To complete the catalog number, replace the ( ) with the appropriate interrupting rating (G, J, K or L). c For 100% rated circuit breakers add a C in the 9th character place. For example, the catalog number for a 100% trip unit with LI trip functions at 250A would be PGL36025CU31A. d For all L interrupting rating, change the 5th character (voltage rating) from a 6 (600V) to a 4 (480V); for example, PLL34025U31A. The 480V AIR is standard 100 kA, but the 600V AIR is only 25 kA.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Table 7.55:
F = No Lugs (Includes terminal nut kit on both ends) L = Lugs both ends M = Lugs ON end, terminal nut kit OFF end P = Lugs OFF end, terminal nut kit ON end D = Drawout A = I-Line (See Section 9)
For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number.
Table 7.56:
Voltage 240 Vac 480 Vac 600 Vac G 65 kA 35 kA 18 kA
PGL36040U41A
Termination Letter
R-frame catalog numbers and pricing . . . . . . . . . . . . . . . . . . . . . . . Page 7-27 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-55 Trip Unit Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-43 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-39 Alternate Rating Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-44 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-36
7-26
DE2
Discount Schedule
Table 7.57:
R-Frame 3000 A (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit
$ Price Sensor Rating Code Cat. No.bc G Interruptingbd 80% Rated J Interruptingbd K Interruptingbd L Interruptingbd 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 22373.00 23549.00 23549.00 35639.00 37512.00 37512.00
100% Rated 1200 A R( )F36120 24723.00 1600 A R( )F36160 ET1.0I 2000 A R( )F36200 2500 A R( )F36250 39383.00 600 A R( )F36060(C)U31A 800 A R( )F36080(C)U31A 27759.00 29301.00 29301.00 30843.00 1000 A R( )F36100(C)U31A 23160.00 24336.00 24336.00 25511.00 1200 A R( )F36120(C)U31A LI 3.0 1600 A R( )F36160(C)U31A 29775.00 31430.00 31430.00 33083.00 2000 A R( )F36200(C)U31A 35042.00 36989.00 36989.00 38936.00 2500 A R( )F36250(C)U31A 36426.00 57075.00 38300.00 60248.00 38300.00 60248.00 40170.00 63417.00 Micrologic 3000 A R( )F36300(C)U31A 54027.00 62451.00 57236.00 65738.00 57236.00 65738.00 60246.00 69024.00 Interchangeable 600 A R( )F36060(C)U33A Standard Trip Unit 800 A R( )F36080(C)U33A 28065.00 29624.00 29624.00 31184.00 1000 A R( )F36100(C)U33A 23501.00 24675.00 24675.00 25851.00 1200 A R( )F36120(C)U33A LSI 5.0 1600 A R( )F36160(C)U33A 30081.00 31752.00 31752.00 33423.00 2000 A R( )F36200(C)U33A 35348.00 37313.00 37313.00 39276.00 2500 A R( )F36250(C)U33A 36767.00 57383.00 38640.00 60570.00 38640.00 60570.00 40511.00 63758.00 3000 A R( )F36300(C)U33A 54513.00 62757.00 57542.00 66060.00 57542.00 66060.00 60570.00 69363.00 600 A R( )F36060(C)U41A 800 A R( )F36080(C)U41A 28493.00 30075.00 30075.00 31658.00 1000 A R( )F36100(C)U41A 24012.00 25188.00 25188.00 26363.00 1200 A R( )F36120(C)U41A LI 3.0A 1600 A R( )F36160(C)U41A 30509.00 32202.00 32202.00 33897.00 2000 A R( )F36200(C)U41A 35775.00 37763.00 37763.00 39750.00 2500 A R( )F36250(C)U41A 37278.00 57809.00 39152.00 61020.00 39152.00 61020.00 41022.00 64232.00 3000 A R( )F36300(C)U41A 54918.00 63185.00 57969.00 66510.00 57969.00 66510.00 61020.00 69836.00 600 A R( )F36060(C)U43A 800 A R( )F36080(C)U43A 29874.00 31533.00 31533.00 33194.00 1000 A R( )F36100(C)U43A Micrologic 25511.00 26685.00 26685.00 27860.00 1200 A R( )F36120(C)U43A Interchangeable LSI 5.0A Ammeter 1600 A R( )F36160(C)U43A 31889.00 33662.00 33662.00 35433.00 Trip Unit 2000 A R( )F36200(C)U43A 37158.00 39221.00 39221.00 41286.00 2500 A R( )F36250(C)U43A 38777.00 59190.00 40649.00 62478.00 40649.00 62478.00 42521.00 65768.00 3000 A R( )F36300(C)U43A 56231.00 64569.00 59354.00 67968.00 59354.00 67968.00 62480.00 71367.00 600 A R( )F36060(C)U44A 800 A R( )F36080(C)U44A 31556.00 33308.00 33308.00 35061.00 1000 A R( )F36100(C)U44A 27378.00 28553.00 28553.00 29729.00 1200 A R( )F36120(C)U44A LSIG 6.0A 1600 A R( )F36160(C)U44A 33570.00 35436.00 35436.00 37301.00 2000 A R( )F36200(C)U44A 38838.00 40995.00 40995.00 43154.00 2500 A R( )F36250(C)U44A 40644.00 60870.00 43368.00 64253.00 43368.00 64253.00 44388.00 67635.00 3000 A R( )F36300(C)U44A 57827.00 66255.00 60965.00 69743.00 60965.00 69743.00 64254.00 73230.00 600 A R( )F36060(C)U63AE1 800 A R( )F36080(C)U63AE1 33845.00 35724.00 35724.00 37605.00 1000 A R( )F36100(C)U63AE1 29922.00 31097.00 31097.00 32273.00 1200 A R( )F36120(C)U63AE1 LSI 5.0P 1600 A R( )F36160(C)U63AE1 35859.00 37853.00 37853.00 39845.00 2000 A R( )F36200(C)U63AE1 41129.00 43413.00 43413.00 45698.00 2500 A R( )F36250(C)U63AE1 43188.00 63161.00 45062.00 66671.00 45062.00 66671.00 46932.00 70179.00 Micrologic 3000 A R( )F36300(C)U63AE1 60003.00 68553.00 63338.00 72161.00 63338.00 72161.00 66671.00 75858.00 Interchangeable 600 A R( )F36060(C)U64AE1 Power Trip Unit 800 A R( )F36080(C)U64AE1 34818.00 36753.00 36753.00 38687.00 1000 A R( )F36100(C)U64AE1 31004.00 32180.00 32180.00 33354.00 1200 A R( )F36120(C)U64AE1 LSIG 6.0P 1600 A R( )F36160(C)U64AE1 36834.00 38880.00 38880.00 40926.00 2000 A R( )F36200(C)U64AE1 42102.00 44441.00 44441.00 46779.00 2500 A R( )F36250(C)U64AE1 44270.00 64136.00 46143.00 67698.00 46143.00 67698.00 48014.00 71261.00 3000 A R( )F36300(C)U64AE1 60929.00 69528.00 64313.00 73188.00 64313.00 73188.00 67698.00 76848.00 600 A R( )F36060(C)U73AE1 800 A R( )F36080(C)U73AE1 37518.00 39603.00 39603.00 41687.00 1000 A R( )F36100(C)U73AE1 35180.00 35180.00 36354.00 34005.00 1200 A R( )F36120(C)U73AE1 LSI 5.0H 1600 A R( )F36160(C)U73AE1 39534.00 41730.00 41730.00 43928.00 2000 A R( )F36200(C)U73AE1 44801.00 47291.00 47291.00 49779.00 2500 A R( )F36250(C)U73AE1 47271.00 66836.00 49143.00 70548.00 49143.00 70548.00 51015.00 74262.00 Micrologic 3000 A R( )F36300(C)U73AE1 63494.00 72236.00 67020.00 76038.00 67020.00 76038.00 70550.00 79841.00 Interchangeable Harmonic Trip 600 A R( )F36060(C)U74AE1 Unit 800 A R( )F36080(C)U74AE1 38493.00 40631.00 40631.00 42770.00 1000 A R( )F36100(C)U74AE1 35087.00 36261.00 36261.00 37436.00 1200 A R( )F36120(C)U74AE1 LSIG 6.0H 1600 A R( )F36160(C)U74AE1 40509.00 42758.00 42758.00 45009.00 2000 A R( )F36200(C)U74AE1 45776.00 48320.00 48320.00 50862.00 2500 A R( )F36250(C)U74AE1 48353.00 67809.00 50225.00 71576.00 50225.00 71576.00 52097.00 75344.00 3000 A R( )F36300(C)U74AE1 64419.00 73212.00 67997.00 77066.00 67997.00 77066.00 71577.00 80919.00 Note: R-frame circuit breakers can be bus- or cable-connected. For cable connections, optional terminal pad kit RLTB or equivalent bus structure is required. Each RLTB kit contains terminal pads for one end of the circuit breaker only and has provisions for mounting a maximum of 8 lugs per phase (9 lugs for 3000 A). RLTB kits are included with 2500 A 100% rated circuit breakers. The RL3TB kits are included with the 3000 A, 80% and 100% rated circuit breakers. For other circuit breakers, order terminal pad kit (RLTB) and optional lugs separately. See pages 7-397-41. a For 2P and 4P information see Catalog 0612CT0101. b To complete the catalog number, replace the blank ( ) with the appropriate interrupting rating (G, J, K or L). c Listed catalog numbers are for 80% rated circuit breakers. For 100% rated circuit breakers add a C in the 9th character place. For example, the catalog number for a 100% standard trip unit with LI trip functions at 2500A would be RGF36250CU31A. d See page 7-26 for interrupting ratings table. Basic Electronic Trip Unit (Not Interchangeable) Fixed long-time, Adjustable Instantaneous
DE2
Discount Schedule
7-27
PowerPact H- and J-Frame Electronic Motor Circuit Protectors Class 611 / Refer to Catalog 0611CT0401
www.schneider-electric.us
PowerPact H- and J-frame electronic Motor Circuit Protectors (MCP) are magnetic-only instantaneous-trip circuit breakers. They are designed to offer short circuit protection and are National Electrical Code (NEC) compliant when installed as part of a combination controller having motor overload protection. MCP circuit breakers accept the same accessories and terminals as the equivalent thermal-magnetic circuit breakers. Determine the hp rating from the nameplate of the motor. Select a MCP with an ampere rating recommended for the hp and voltage involved. When using the automatic settings the MCP microprocessor automatically adjusts the trip settings for both current and time to align with the start-up characteristic for the motor type, whether it is a standard or energyefficient motor. This includes a dampening means to accommodate a transient motor inrush current without nuisance tripping of the circuit breaker. Table 7.58:
Frame
dard Stan ient Effic ace rgy Energie Effic e ient Energia Efic Ene
H-Frame J-Frame
Standard Energy Efficient Energie Efficace Energia Eficiente
Table 7.59:
A, B, C, D B, E a b
800% 1100%
Based on 2005 NEC Table 430.52. See NEC Exception No. 1 to Table 430.52. The NEC 1300% maximum setting may be inadequate for instantaneous trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, and motors labeled high efficiency.
Table 7.60:
I
Motor Type / Tipo de Motor / Type de Moteur
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Based on 2005 NEC Table 430.250. Per NEC 430.3, part-winding motors should select two circuit breakers, each at not more than one-half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NEC 430.103. Listed voltages are rated motor voltages. Corresponding system voltages are 200 Vac, 220240 Vac, 440480 Vac and 550600 Vac. Select wire and circuit breakers based on horsepower rather than nameplate full-load current per NEC 430.6 (A) for general motor applications.
7-28
DE2
Discount Schedule
H-Frame and J-Frame MCP Selector Class 611 / Refer to Catalog 0611CT0401
Table 7.62:
Starter Size
Application of PowerPact H-Frame and J-Frame Electronic Motor Circuit Protectors (MCP)
200 Vac 230 Vac 480 Vac 1/2 3/4 1 1/2 1-1/2 1/2 2 1-1/2 3/4 1 575 Vac 1/2 NEC Full Load Amperes 0.9 A 1.1 A 1.3 A 1.7 A 2.1 A 2.2 A 2.4 A 2.5 A 2.7 A 3A 3.2 A 3.4 A 3.7 A 3.9 A 4.2 A 4.8 A 4.8 A 6A 6.1 A 6.8 A 6.9 A 7.6 A 7.8 A 9A 9.6 A 11 A 14 A 15.2 A 17 A 17.5 A 21 A 22 A 25.3 A 27 A 28 A 32 A 32.2 A 34 A 40 A 41 A 42 A 48.3 A 52 A 54 A 62 A 65 A 68 A 77 A 78.2 A 80 A 92 A 96 A 99 A 104 A 120 A 124 A 125 A 130 A 144 A 150 A 154 A 156 A 177.1 A 180 A 192 A 221 A 240 A 248 A PowerPact H-Frame and J-Frame Electronic MCP
00 3/4
0 3 3 5 7-1/2 10
7-1/2 10
15 1 5 15 7-1/2 7-1/2 20 2 10 25 30 40 15 15 3 20 50 25 60 25 30 30 4 40 40 100 125 50 150 50 5 60 150 75 75 200 100 Shaded area is not covered by J-frame electronic motor circuit protector. 200 60 125 75 100 75 40 20 60 50 10 30 25 20
1550 hp
7-29
Mag-Gard Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard circuit breakers comply with NEC requirements for providing motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection. Interrupting ratings are established for these UL Recognized Components only when they are used in combination with motor starters with properly sized overload relays and contactors. All Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent circuit breakers. Mag-Gard circuit breakers are available with I-Line construction.c High-interruption (H) construction Mag-Gard circuit breakers (LHL and MHL) are also available. Table 7.63:
Ampere Rating 3 7 15 30 50 75
GJLc
LAL
400
25M 26M 30M 33M 7560.00 600 36M MAL36600 Add 9927.00 MALd 800 40M MAL36800 Suffix 12705.00 1000 42M MAL361000 44M 45M 46M 47M J-Interrupting600 Vac 600 120010000 A PJL36060M68 7560.00 800 120010000 A PJL36080M68 9927.00 1000 150010000 A PJL36100M69 12705.00 1200 180010000 A PJL36120M70 16517.00 PJL PLL L-Interrupting480 Vac 600 120010000 A PLL34060M68 8006.00 800 120010000 A PLL34080M68 10514.00 1000 150010000 A PLL34100M69 13455.00 1200 180010000 A PLL34120M70 17492.00 a 250 Vdc ratings are available except on PJ and PL. No UL component recognition.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
b c d
250 Vdc Multiplier High = 1.2 Low = 1.4 High = 1.1 Low = 1.2
UL magnetic trip tolerances are -20%/+30% from the nominal values shown. No GJL I-Line available. Each ampere rating can be ordered with any designated trip range for the frame by adding the proper suffix to the catalog numbers.
Accessories . . . . . . . . . . . . . . . . . . . . . . Page 7-36 and Supplemental Digest Optional Lugs . . . . . . . . . . . . . . . . . . . . . Page 7-39 and Supplemental Digest Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7-54 and 7-55 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56
7-30
DE2
Discount Schedule
Adjustable instantaneous-trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders. These circuit breakers contain a magnetic trip element in each pole with the trip point adjustable from the front. Interrupting ratings are determined by testing the instantaneous-trip circuit breakers in combination with a contactor and overload relay. Select instantaneous-trip circuit breakers as follows: This selection table is suitable for motors, other than NEMA Design E, with locked-rotor indicating code letters per NEC Table 430.7 (b) as follows: Table 7.64: Locked-Rotor Indicating Codes
Motor Code letter AL AK AJ AH AG AF
4.
5.
6.
1.
For other motors order a special thermal-magnetic circuit breaker with magnetic trip settings for the specific motor
7.
Table 7.65:
GJL Adjustable Instantaneous-Trip Circuit Breakers for Single Motor Circuit Protection
GJL Family Full Mag-Gard Load Circuit Breaker Amperesa Cat. No. 0.8 1 1.1 1.4 1.8 2 2.1 2.3 2.6 2.7 2.8 3.2 3.4 3.6 3.9 4.1 4.8 5.2 6 6.1 6.8 7.6 7.8 9 9.6 11 14 15.2 17 17.5 21 22 25.3 27 28 32 32.2 34 40 41 42 48.3 52 54 62 65 Magnetic Trip Settingsb
Table 7.66:
LAL and MAL Adjustable InstantaneousTrip Circuit Breakers for Single Motor Circuit Protection
Full Mag-Gard Load Circuit Breaker Amperesa Cat. No. Magnetic Trip Settingsb
Hp Ratings of Induction Type Squirrel-Cage and Wound Rotor Motors 3 60 Hz 200 Vac 230 Vac 460 Vac 1/2 3/4 3/4 1 1/2 1-1/2 1/2 1-1/2 2 3/4 3/4 2 1 3 1 3 1-1/2 1-1/2 5 2 5 2 7-1/2 3 3 5 15 5 15 7-1/2 7-1/2 20 10 30 10 25 30 40 15 15 40 20 20 50 60 50 25 20 7-1/2 10 10 575 Vac 1/2
Hp Ratings of Induction Type Squirrel-Cage and Wound Rotor Motors 3 60 Hz 200 Vac 75 230 Vac 460 Vac 575 Vac
MIN GJL36003M01c 1100% GJL36003M01c 900% GJL36003M01c 800% GJL36003M01 600% GJL36003M01 500% GJL36003M01 500% GJL36003M01 400% GJL36003M01 400% GJL36003M01 300% GJL36003M01d 300% GJL36003M01d 300% GJL36007M02 700% GJL36007M02 600% GJL36007M02 600% GJL36007M02 500% GJL36007M02 500% GJL36007M02 400% GJL36007M02 400% GJL36007M02 400% GJL36015M03 700% GJL36015M03 700% GJL36015M03 600% GJL36015M03 600% GJL36015M03 500% GJL36015M03 500% GJL36015M03 400% GJL36030M04 600% GJL36030M04 600% GJL36030M04 500% GJL36030M04 500% GJL36030M04 400% GJL36030M04 400% GJL36030M04 400% GJL36050M05 600% GJL36050M05 500% GJL36050M05 500% GJL36050M05 500% GJL36050M05 400% GJL36050M05 400% GJL36050M05 400% GJL36075M06 400% GJL36075M06 500% GJL36075M06 400% GJL36075M06 400% GJL36075M06 400% GJL36075M06 300%
MAX 4100% 3300% 3000% 2400% 1800% 1700% 1600% 1400% 1300% 1200% 1200% 2400% 2300% 2100% 2000% 1900% 1600% 1500% 1300% 2700% 2400% 2200% 2100% 1800% 1700% 1500% 2400% 2200% 1900% 1900% 1600% 1500% 1300% 2000% 2000% 1700% 1700% 1600% 1400% 1300% 1300% 1700% 1600% 1500% 1300% 1300%
MIN
MAX
100
125
150
200
b c d
221 LAL3640033M 700% 1400% 200 240 LAL3640035M 700% 1500% 250 242 LAL3640035M 700% 1400% 100 248 LAL3640035M 700% 1400% 285 LAL3640036M 700% 1400% 300 289 LAL3640036M 700% 1400% 250 302 LAL3640036M 700% 1300% 125 312 LAL3640036M 600% 1300% 350 336 MAL3660040M 700% 1500% 359 MAL3660040M 700% 1400% 150 360 MAL3660040M 700% 1400% 300 361 MAL3660040M 700% 1400% 400 382 MAL3660040M 700% 1300% 350 414 MAL3660042M 700% 1400% 500 472 MAL3660044M 700% 1500% 400 477 MAL3660044M 700% 1500% 200 480 MAL3660044M 700% 1500% 552 MAL3680045M 700% 1400% 500 590 MAL3680045M 700% 1400% 250 602 MAL3680045M 700% 1300% Motor full-load currents are taken from NEC Table 430.150. Select wire and circuit breakers on basis of horsepower rather than nameplate full-load current per NEC 430.6 (A) for general motor applications. Do not use these values to select overload relay thermal units. See Digest pages 14-12914-152 for selection of thermal units when actual full load current is not known. The voltages listed are rated motor voltages. Corresponding nominal system voltages are 200208, 220240, 440480 and 550600 V. Only MIN and MAX settings are shown, intermediate settings are available on all circuit breakers. See NEC 430.52(A) for circuit breaker settings above 800%. If due to motor starting characteristics, trip settings at the 1300% maximum permitted level are needed, the next size Mag-Gard circuit breaker should be chosen.
7-31
Table 7.67:
Selection Tables for Conductors, Safety Switches and Thermal-Magnetic Circuit Breakers Based on 2005 NEC Tables 430.147, 430.148 & 430.150
Horsepower Ratings Amperage of Thermal-magnetichj Inverse Time Circuit Breaker For Motor Code Heavy Service Letter Ordinary and Energy F to Vi Servicec Efficientd 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A 20 A 20 A 20 A 20 A 25 A 25 A 25 A 25 A 30 A 30 A 30 A 35 A 35 A 40 A 40 A 40 A 45 A 50 A 50 A 50 A 50 A 60 A 60 A 60 A 60 A 80 A 80 A 80 A 80 A 90 A 90 A 90 A 90 A 90 A 90 A 90 A 90 A 90 A 100 A 100 A 100 A 100 A 110 A 125 A 110 A 110 A 110 A 125 A 125 A 125 A 150 A 150 A 150 A 175 A 175 A 200 A 200 A 200 A 200 A 200 A 200 A 225 A 225 A 250 A 250 A 250 A 250 A 300 A 350 A 350 A 350 A 400 A 400 A 400 A 450 A 500 A 600 A 600 A 600 A 600 A 600 A 800 A 800 A 800 A 800 A 900 A 900 A 15 A 15 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 25 A 25 A 20 A 25 A 25 A 30 A 30 A 35 A 35 A 35 A 35 A 40 A 40 A 45 A 45 A 50 A 50 A 60 A 60 A 60 A 60 A 70 A 70 A 70 A 80 A 80 A 90 A 90 A 110 A 110 A 110 A 110 A 110 A 110 A 125 A 125 A 125 A 125 A 125 A 150 A 150 A 150 A 175 A 175 A 175 A 175 A 175 A 200 A 200 A 200 A 200 A 225 A 225 A 250 A 250 A 250 A 300 A 300 A 300 A 300 A 350 A 350 A 350 A 400 A 400 A 400 A 450 A 500 A 500 A 500 A 600 A 600 A 700 A 700 A 700 A 800 A 800 A 800 A 800 A 900 A 1000 A 1000 A 1000 A 1200 A 1200 A 1200 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 25 A 25 A 25 A 25 A 25 A 25 A 30 A 30 A 30 A 35 A 35 A 35 A 35 A 40 A 40 A 45 A 45 A 50 A 50 A 60 A 60 A 60 A 70 A 70 A 70 A 70 A 80 A 80 A 90 A 90 A 100 A 100 A 110 A 110 A 125 A 125 A 125 A 150 A 150 A 150 A 150 A 150 A 150 A 175 A 175 A 175 A 175 A 200 A 200 A 200 A 200 A 200 A 225 A 250 A 250 A 250 A 250 A 300 A 300 A 300 A 350 A 350 A 350 A 350 A 400 A 400 A 400 A 400 A 400 A 500 A 500 A 500 A 600 A 600 A 700 A 700 A 800 A 800 A 800 A 800 A 900 A 900 A 1000 A 1000 A 1000 A 1200 A 1200 A 1200 A 1200 A 1600 A 1600 A 1600 A For Motor Code Letter B to E QMB and Heavy Duty Switch with Time Delay Fusesg Minimum Size Metallic Conduit 75C, C Wire Field-Installed Sized for 125% FLAe Conduit 3 W AWG THHN kcmil THWN THW XHHW
Squirrel-Cage and Wound-Rotor Motors with Norm. Torque Characteristics Operating at Usual Speeds 200 Vacb 3 60 Hz 230 460 Vac Vac 5 2 a 8 XHHW requires 3/4 in. conduit for 3W. b200 V motors are commonly used on 208 V services. cOrdinary service for normal starting duty only, acceleration time of 10 sec. or less. dHeavy service is jogging or plugging duty or cycling load with over 25 3 starts per hour or over 5 starts per minute. Energy efficient motors are polyphase motors defined in NEMA Standard MG1 and exhibit high starting current. eNEC 430.22 for Single Motor, Smaller conductors may be permitted for light duty-cycle service per 430.22 (B) Exception No. 1. DC motors operating from rectified 1 5 power supply will require larger conductors per 430.22 (A) Exception No. 1. For motor-generator arc welders, see 630.11. fMotor full load currents thru 200 hp are taken from NEC Tables 430.147, 148 and 150. Above 200 hp from UL 7-1/2 98. Select wire size, circuit breakers, or fuses on basis of hp rather than nameplate full load current per NEC 430.6. Do not use these values to select overload relay thermal 10 units. See Digest pages 16-129 16-152 for selection of thermal units when actual full load current is not known. Voltages listed are rated motor voltages. Corresponding nominal system voltages are 110 120 V, 200208 V, 220240 V, 440 15 480 V and 550600 V. gSwitch size only is shown in table. Selected fuses should not exceed maximum percent of full-load current as given in NEC Table 430.52. Above 50 hp dc switches are not hp rated by UL as Motor Circuit Switches, but as General Use Switches only and are not 20 necessarily capable of interrupting the max. operating overload current of a motor. See NEC 100 for definition of General Use Switch. When protecting a 3, Design E energy efficient motor, the switch is 25 required by NEC 430.109 to have a hp rating of not less than 1.4 times that of a motor rated 3100 hp, or not 30 less than 1.3 times that of a motor rated over 100 hp. Switches shown in this table do not necessarily comply with that requirement. hThermal-magnetic circuit breaker ampere ratings recommended are 40 approximate for average conditions, based on trip characteristics of Square D circuit breakers and NEC Table 430.52. Under some conditions, the next size larger switch or circuit breaker rating may be 50 necessary to accommodate the motor starting current and is permitted by NEC 430.52(C)(1) Exception 2. High starting currents 60 are anticipated with Design E and other energy efficient motors. For explanation of Code letter markings, 75 see NEC 430.7(B). For Busway Plugin units, see page 9-7. iThermal-magnetic breaker ampere ratings recommended are 100 approximate for average conditions and based on trip characteristics of Square D circuit breakers and NEC Tables 430.7(B) and 430.52. jType LC, LI, LX, LXI, and LE circuit 125 breakers are NOT recommended for use on single motor branch circuits. Contact your local Field Office for 150 circuit breaker selection on constant horsepower multi-speed motors. 200 575 Vac
Average f Direct Current Full Motors Load Operating at Base Speed Amperage 120 Vdc 3/4 240 Vdc 6.9 A 7.2 A 7.6 A 7.8 A 7.9 A 8.0 A 8.5 A 9.0 A 9.2 A 9.5 A 9.6 A 9.8 A 10.0 A 11.0 A 11.5 A 12.0 A 12.2 A 13.2 A 13.8 A 14.0 A 15.2 A 16.0 A 17.0 A 17.5 A 19.6 A 20.0 A 21.0 A 22.0 A 24.0 A 25.0 A 25.3 A 27.0 A 28.0 A 29.0 A 32.0 A 32.2 A 34.0 A 38.0 A 40.0 A 41.0 A 42.0 A 46.0 A 48.3 A 50.0 A 52.0 A 54.0 A 55.0 A 56.0 A 57.5 A 58.0 A 62.0 A 62.1 A 65.0 A 68.0 A 72.0 A 76.0 A 77.0 A 78.2 A 80.0 A 89.0 A 92.0 A 96.0 A 99.0 A 100.0 A 104.0 A 106.0 A 120.0 A 124.0 A 125.0 A 130.0 A 140.0 A 144.0 A 150.0 A 154.0 A 156.0 A 173.0 A 177.0 A 180.0 A 192.0 A 221.0 A 240.0 A 242.0 A 248.0 A 285.0 A 289.0 A 302.0 A 312.0 A 336.0 A 359.0 A 360.0 A 361.0 A 382.0 A 414.0 A 472.0 A 477.0 A 480.0 A 552.0 A 590.0 A 602.0 A
3/4 1 2 7-1/2 1 1 3 1/2 1-1/2 7-1/2 10 1-1/2 2 3 1-1/2 3/4 10 5 1 15 3 1-1/2 15 7-1/2 2 3 20 10 30 25 30 15 7-1/2 10 40 20 15 5 10 7-1/2 60 50 25 20 10 60 30 75 100 10 40 30 100 125 50 40 150 60 125 50 150 75 200 250 100 300 250 125 350 150 300 400 350 500 400 200 500 250 200 75 7-1/2 25 50 3 10 7-1/2 5 25 5 7-1/2 5 3 2 2
14 30 A
1/2 in.
N/A
12
1/2 in.
N/A
10
1/2 in.
N/A
60 A
1/2 in.a
3/4 in.
3/4 in.
1"
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
4 100 A
1 in.
1"
1 in.
1-1/4 in.
1 in.
1-1/4 in.
1-1/4 in. 1-1/2 in. 1-1/4 in. 1-1/2 in. 1-1/2 in. 1-1/2 in.
3/0
1-1/2 in.
2 in.
(2) 3/0 (2) 1-1/2 (2) 2 in. (2) 4/0 (2) 2 in. 600 A (2) 2 in.
(2) 300 (2) 2 in. (2) 2-1/2 in. (2) 350 (2) 2-1/2 (2) 2-1/2 in. in. 2-1/2 (3) 300 (3) 2 in. (3) in. 2009 Schneider Electric All Rights Reserved
7-32
Automatic Switches
Class 600 / Refer to Catalog 0612CT0101
www.schneider-electric.us
Automatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection. Molded case switches open when the handle is switched to the OFF position or in response to an auxiliary tripping device such as a shunt trip. All molded case switches will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers, with the exception of Q-frame switches which do not have electrical accessories available. Automatic molded case switches are UL Listed per UL 489 and are CSA Certified. Table 7.68:
J-Frame Switch
Poles
H-Frame and J-Frame PowerPact Automatic Molded Case Switches, 600 Vac
G Interrupting L Interrupting Cat. No. HLL26000S15 JLL26000S17 JLL26000S25 HLL36000S15 JLL36000S17 JLL36000S25 $ Price 1590.00 1980.00 1980.00 1988.00 2475.00 2475.00 Trip Point 2250A 3125 A 3125 A 2250 A 3125 A 3125 A Terminal AL150HD AL175JD AL250JD AL150HD AL175JD AL250JD Wire Range 14 AWG3/0 AWG Al/Cu 44/0 AWG Al/Cu 3/0 AWG350 kcmil Al/Cu 14 AWG3/0 AWG Al/Cu 44/0 AWG Al/Cu 3/0 AWG350 kcmil Al/Cu
Cat. No. $ Price Trip Point 150 A HGL26000S15a 1349.00 2250 A 2 175 A JGL26000S17 1827.00 3125 A 250 A JGL26000S25 1827.00 3125 A 150 A HGL36000S15 1799.00 2250 A 3 175 A JGL36000S17 2286.00 3125A 250 A JGL36000S25 2286.00 3125A a True 2P device. Others are a 2P in a 3P module.
Ampere Rating
Table 7.69:
D-Frame Switch
Circuit Breaker Poles
D-Frame (600 Vac) and Q-Frame (240 Vac) PowerPact Automatic Molded Case Switches
Ampere Rating J Interrupting $ Price 4572.00 7484.00 440.00 1193.00 Trip Point 6000 A 6000 A 4500 A 4500 A Terminal S32508 S32510 Wire Range 2 AWG500 kcmil Al or 2 AWG600 kcmil Cu (2) 2/0 AWG500 kcmil Al or (2) 2/0 AWG350 kcmil Cu 4 AWG300 kcmil
Cat. No. 400 A DJL36000S40 D-Frame 3 600 A DJL36000S60 2 225 A QBL22000S22c Q-Frameb 3 225 A QBL32000S22c b Withstand rating of 10 kA at 240 Vac. c DE2A discount schedule.
Table 7.70:
Frame Poles
P-Frame and R-Frame PowerPact Automatic Molded Case Switchese, 600 Vac
Ampere Rating 600 A 800 A 1000 A 1200 A 600 A 800 A 1000 A 1200 A 1200 A 1600 A 2000 A 2500 A 1200 A 1600 A 2000 A 2500 A 3000 A J Interrupting K Interrupting L Interrupting $ Price Trip Point 5715.00 10 kA 6414.00 10 kA 7995.00 10 kA 10887.00 10 kA 6974.00 10 kA 7667.00 10 kA 9837.00 10 kA 12570.00 10 kA 12855.00 48 kA 14825.00 48 kA 15837.00 48 kA 25185.00 48 kA 14318.00 48 kA 16062.00 48 kA 19559.00 48 kA 31130.00 48 kA 41496.00 48 kA Cat. No. $ Price Trip Point Cat. No. $ Price Trip Point Cat. No. PJL26000S60 5340.00 10 kA PKL26000S60 5340.00 24 kA PLL24000S60d PJL26000S80 5991.00 10 kA PKL26000S80 5991.00 24 kA PLL24000S80d PJL26000S10 7469.00 10 kA PKL26000S10 7469.00 24 kA PLL24000S10d PJL26000S12 11744.00 10 kA PKL26000S12 11744.00 24 kA PLL24000S12d PJL36000S60 6584.00 10 kA PKL36000S60 6584.00 24 kA PLL34000S60d PJL36000S80 7236.00 10 kA PKL36000S80 7236.00 24 kA PLL34000S80d PJL36000S10 9287.00 10 kA PKL36000S10 9287.00 24 kA PLL34000S10d PJL36000S12 11867.00 10 kA PKL36000S12 11867.00 24 kA PLL34000S12d RKF26000S12 12213.00 57 kA RLF26000S12 RKF26000S16 14685.00 57 kA RLF26000S16 RKF26000S20 15687.00 57 kA RLF26000S20 RKF26000S25 24948.00 57 kA RLF26000S25 RKF36000S12 13602.00 57 kA RLF36000S12 RKF36000S16 15911.00 57 kA RLF36000S16 RKF36000S20 19374.00 57 kA RLF36000S20 RKF36000S25 30836.00 57 kA RLF36000S25 RKF36000S30 41104.00 57 kA RLF36000S30 d P-frame L-interrupting is available in 480 Vac only. e UL magnetic trip tolerances are -20% / +30% from the nominal values shown. Terminal AL800M23K AL1200P25K AL800M23K AL1200P25K Wire Range (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu
2 P 3
R 3
R-frame circuit breakers can be bus-connected or cable-connected. For cable connections, RLTB kit or equivalent bus structure is required. Kit is included with 3000 A switches. For all others, see page 7-41.
Table 7.71:
Table 7.72:
Voltage
G J K L 240 Vac 65 kA 100 kA 65 kA 125 kA 480 Vac 35 kA 65 kA 50 kA 100 kA 600 Vac 18 kA 25 kA 50 kA 50 kA f The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating.
Voltage
Interrupting J 240 Vac 150 kA 480 Vac 100 kA 600 Vac 25 kA The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating.
Accessories . . . . . . . . . . . . . . . . . . . . . . Page 7-36 and Supplemental Digest Optional Lugs . . . . . . . . . . . . . . . . . . . . . Page 7-39 and Supplemental Digest Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7-54 and 7-55 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7-567-58
DE2
DE2A
Discount Schedule
7-33
The UL Listed thermal-magnetic molded case circuit breakers shown below are specifically designed for use on ungrounded dc systems having a maximum short-circuit voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. The circuit breakers are suitable for use only with UPS (uninterruptable power supplies) and ungrounded systems. This two-level voltage rating allows these circuit breakers to be applied to battery sources having a short-circuit availability of 20,000 amperes for FH, KH, LH, and MH circuit breakers and 25,000 amperes for PAF circuit breakers at 500 Vdc. FH, KH, LH and MH circuit breakers are provided with an adjustable magnetic trip that is readily accessible by means of a single adjustment on the face of the circuit breaker. PAF circuit breakers have a fixed magnetic trip range. These circuit breakers are UL Listed for the interrupting ratings shown only if applied with three poles connected in series (series connection is external to circuit breaker). See diagram below. NOTE: Due to external series connection, I-Line circuit breakers are not available for this application.
CAUTION/PRECAUCION/ ATTENTION
Connect only as shown/Conectar solo asi/ Francher seulement comme suit: 300 V 300 V 600 V MAX. or MAX. MAX. o ou Load/Carga/ Charge Load/Carga/ Charge
Source = 600 Vdc max. (floating) 500 Vdc max. (loaded) Table 7.73:
Ampere Rating 100 A 125 A 150 A 175 A 200 A 225 A 250 A 30 A 50 A 100 A 250 A 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 900 A 1000 A 1200 A
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
New!
Ampere Rating
a b
Interrupting Rating $ Price @ 500 Vdc Hold Trip 1200 A PAF361200DC 1200 1620 24726.00 1600 A PAF361600DC 1600 2160 25 k AIR 24726.00 2000 A PAF362000DC 2000 2700 24726.00 2500 A PCF362500DC 2500 3375 25 k AIR 39365.00 Magnetic trip tolerances are -20%/+30% from the nominal values shown. Suitable for use only in a ventilated enclosure. Minimum enclosure dimensions are 38" h x 20" w x 7" d with a minimum of 300 square inches of ventilation near the top and bottom of the enclosure.
Accessories . . . . . . . . . . . . . . . . . . . . . . Page 7-36 and Supplemental Digest Optional Lugs . . . . . . . . . . . . . . . . . . . . . Page 7-39 and Supplemental Digest Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7-54 and 7-55 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7-567-58
7-34
DE2
Discount Schedule
Continuity of service is important for most industrial and commercial customers. To ensure maximum continuity of service, electrical distribution systems are typically selectively coordinated in order to restrict outages to the circuit or equipment affected by an overload or short-circuit. In order to ensure maximum continuity of service, Square D has developed a line of Mission Critical circuit breakers to ensure selective coordination.
New!
New!
Circuit Breaker Cat. No. NFNL32225W NFNL32250W NFNL32225WLY NFNL32250WLY NFNF32225W NFNF32250W
Ampere Rating
LA/LH MC Circuit Breaker, 3P, 480 Vac 200 A 3400 A 4000 A 225 A 3825 A 4500 A 250 A 4250 A 5000 A 400 A 6000 A 7200 A
(1) 250350 kcmil Al (1) 3/0 AWG350 kcmil Cu (1) 1 AWG600 kcmil Al or (2) 1 AWG250 kcmil Al
When the D-frame Mission Critical circuit breaker is used as a main circuit breaker with QO branch circuit breakers, the D-frame MC will remain closed during any fault that occurs downstream of the QO circuit breaker up to 30kA at 208Y/120 Vac.
Circuit Breaker Continuous Current Terminal Wire Range Cat. No.a Rating (AWG/kcmil) DJM32150W 150 A DJM32250W 250 A #2-600 Cu or #2-500 Al DJM32400W 400 A DJM32600W 600 A (2) 2/0-350 Cu or (2) 2/0-500Al D-Frame circuit breakers 400 A and below are 100% rated. $ Price 10317. 10317. 10317. 13551.
Table 7.76:
Frame
Termination Options
Termination Option No Lugs (Includes terminal nut kit on both ends) Lugs both ends Lugs ON end Terminal Nut Kit Off end Lugs OFF end Terminal Nut Kit On end Plug-in Drawout Rear Connected
D-Frame
Termination Letter F L M P Nb Db Sb
For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number.
DGL36400E20
Termination Letter
b For N, D, and S pricing, add termination pricing to price. See page 7-42.
DE2
Discount Schedule
7-35
Electrical Accessories
Class 612 / Refer to Catalog 0612CT0101
www.schneider-electric.us
H-, J-, and D-Frame H- and J-Frame D-Frame FieldInstallable Cat. No. S29450 2x S29450 3x S29450 S29450
M-, P-, and R-Frame Factory FieldInstalled Installable $ Price $ Price Cat. Suffix Cat. No. 297.00 594.00 891.00 297.00 AA AB AC BC BD BE AE AF AG BH BJ BK SK SL SA SC SD SH SN SK SK SL SL SA SC UK UL UA UC UH UK UK UL UL UA UC FL FA FC FH KA KC S29450 2x S29450 3x S29450 S29450 S29450 2x S29450 297.00 594.00 891.00 297.00 297.00 594.00
G-Frame
Note: The location of the accessory in the circuit breaker determines its function. Low Level Min Load = 1mA with 24V
Trips the circuit breaker from a remote location by means of a trip coil energized from a separate supply voltage circuit.
G-Frame
Undervoltage Trip Instantaneously opens the circuit breaker when the under-voltage trip supply voltage drops to a value between 35% and 70% of its rated voltage. Closing is allowed when the supply voltage of the undervoltage trip reaches 85% of rated voltage.
G-Frame
1 auxiliary switch (OF) 1a1b 2 auxiliary switch (OF) 2a2b 3 auxiliary switch (OF) 3a3b Alarm Switch (SD) 1a1b Overcurrent trip switch (SDE) 1a1b OF Switch Consisting of: SDE Adapter Alarm switch and Overcurrent trip switch OF Switch Consisting of: SDE Adapter Auxiliary Switch/Alarm Switch/Adapter (OF/SD/SDE) Kit One auxiliary switch (OF) 1a1b Two auxiliary switches (OF) 2a2b 3 auxiliary switches (OF) 3a3b Alarm Switch (SD) 1a1b Overcurrent trip switch (SDE) 1a1b OF Switch Consisting of: SDE Adapter Alarm switch and Overcurrent trip switch OF Switch Consisting of: SDE Adapterd 24 48 120 110/130 208 240 AC 200/250 277 208/277 480 380/480 525/600 12 24 30 DC 48 60 125 250 24 48 120 110/130 208 240 AC 200/250 277 208/277 480 380/480 525/600 12 24 30 DC 48 60 125 250 48/60 100/130 AC/DC 200/250 380/480
FieldFactoryFieldInstallable $ Price Installed Cat. No. Cat. Suffix Installable $ Price Cat. No. AAC 297.00 AA S29450 297.00 AB 2x S29450 594.00 AC AAC 297.00 BC S29450 297.00 GSA GSB GSC GSD GSH GSO GSP GSR GSS GUA GUB GUC GUD GUH GUO GUP GUR GUS BD BE AE AF AG BH BJ BK SK SL SA SD SH SJ SN SO SU SP SV SR SS UK UL UA UD UH UJ UN UO UU UP UV UR US 338.00
S29450 297.00
S33801c 297.00 S29452 372.00 2x S29452 744.00 3x S29452 1116.00 S29452 372.00 S29452 2x S29452 372.00 744.00
S29452 372.00 S29452 372.00 2x S29452 744.00 2x S29452 744.00 3x S29452 1116.00 S29452 372.00 S29452 372.00 413.00 S29452 372.00
785.00 2x S29452 744.00 S29384 S29385 S29386 S29387 S29388 S29389 S29382 S29390 S29391 S29392 S29383 S29393 S29394 S29404 S29405 S29406 S29407 S29408 S29409 S29402 S29410 S29411 S29412 S29403 S29413 S29414
717.00
2x S29452 744.00 S29451 40.50 S29384 S29385 S29386 717.00 S29387 S29388 S29389 S29382 S29390 S29391 S29392 717.00 S29383 S29393 S29394 S29404 S29405 S29406 717.00
717.00
717.00
717.00
717.00
S29407
717.00
717.00
S29408 S29409 S29402 S29410 S29411 S29412 717.00 S29403 S29413 S29414
717.00
Undervoltage trip with externally mounted adjustable time delay unit for UVR of 0.5, 0.9, 1.5, 3.0 seconds before circuit breaker trips
a b c d
Undervoltage trip with 100/130 externally mounted non-adjustable time AC/DC delay unit of 0.25 sec 200/250 before circuit breaker trips. Field-installable kit includes time delay module only. Order undervoltage trip separately. Discount schedule DE2F. P-frame drawout circuit breaker only. SDE Adapter used for H- and J-frame only.
S33659 S33660 S33661 755.00 S33662 S33663 S33664 S33658 S33659 S33659 S33660 755.00 S33660 S33661 S33662 S33668 S33669 S33670 755.00 S33671 S33673 S33668 S33668 S33669 755.00 S33669 S33670 S33671 S33680a b S33681a b 1140.00 S33682a b S33683a b S33684a b 930.00 S33685a b
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
7-36
DE2
DE2F
Discount Schedule
Motor Operators and Rotary Handles Class 612 / Refer to Catalog 0612CT0101
Table 7.78:
1161.00
3123.00
3395.00
3395.00
1161.00
3123.00
3545.00
3545.00
Motor Operator
Locking Device Operations Counter Adapter for I-Line
119.00
119.00
Table 7.79:
AC Standard motor for electricallyoperated circuit breakers. Factory-installed includes motor and opening/closing coils. DC
3580.00
755.00
3580.00
755.00
AC
3580.00
755.00
Spring-charging Motor
Communicating motor mechanism for electrically operated circuit breakers. Factory-installed includes motor and opening/closing coils. DC
3580.00
755.00
Table 7.80:
Standard Black Handle with Direct Mounted Red handle on yellow bezel
MCC Conversion Accessory Standard black handle Door Mounted Standard Black Handle with:
Red handle on yellow bezel Rotary Handle Replacement Kit Telescoping Key lock adapter Accessories Key locks Indication Auxiliary Switch
Direct-Mounted handle
a b c
Door-Mounted Handle
Not available in H-frame 2P modules. CP1 discount schedule. DE2F discount schedule.
DE2F
CP1
DE2
Discount Schedule
7-37
Locks, Installation Accessories, and Rear Connections Class 612 / Refer to Catalog 0612CT0101
www.schneider-electric.us
H- and J-Frame
Q-Frame
D-Frame
M- and P-Frame
Removable (lock OFF only) Fixed (lock OFF or ON)a Fixed (lock OFF only) Mechanical for circuit breakers with rotary Interlocking handlesa (Not UL listed) Mechanical for circuit breakers with togglesa Provision only, vertical Kirk or Federal mount, 1 or 2 locks Pioneer Provisions only, vertical mounting one key Kirk or Federal interlock including Pioneer padlock provision, open position only. Kirk Key Locking Provision only, horizontal Federal Pioneer mount 1 lock, M- and P-frame Ronis 1 or 2 locks, R-frame Profalux Kirk Provision and 1 lock, vertical mount Federal Pioneer Kirk Federal Pioneer Provision and 1 lock, horizontal mount Ronis Profalux Kirk Federal Pioneer Provision and 2 locks keyed alike Ronis Profalux Kirk Provision and 2 locks keyed differently Federal Pioneer a Not available in M frame or HD and HG 2P modules.
Factory Factory FieldFieldFieldFieldFieldFieldInstalled $ Price Installed $ Price Installed $ Price Installed $ Price Installed Installed $ Price Installed Installed Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Suffix Suffix AHP 19.70 S29370 51.00 S29370 50.00 S44936 50.00 S33996 S29371 77.00 QBPA 77.00 S32631 122.00 YP S32631 122.00 YP S32631 S37422 122.00 QBPAF 77.00 NJPAF 122.00 YQ MPRPAF 122.00 YQ MPRPAF S29369 494.00 S29354 494.00 QBMIK 90.00 32621 32614 494.00 494.00 JA S33890 1220.00 323.00
41950 42878
183.00 183.00
JE JK JR JB JD JG JH JL JS JC JF JN JV JP JW
445.00 323.00 323.00 323.00 323.00 1796.00 1796.00 1796.00 1796.00 2285.00 2285.00 2285.00 2285.00 3269.00 3269.00
JE JK JR JB JD JL JS JC JF JN JV JP JW
445.00 323.00 323.00 323.00 323.00 1796.00 1796.00 2285.00 2285.00 2285.00 2285.00 3269.00 3269.00
Table 7.82:
Installation Accessories for G-, H-, J-, and D-Frame Circuit Breakers
H- and J-Frame Description FieldInstalled Cat. No. S29315 S29317 S29329 S29319 29375 S29305 S29313 $ Price 48.00 63.00 53.00 135.00 42.00 188.00 140.00 G-Frame FieldInstalled Cat. No. ACS GYR $ Price 18.50 93.00 D-Frame FieldInstalled Cat. No. 32556 32558 32570 32560 29375 32553 $ Price 55.00 74.00 72.00 171.00 42.00 33.20
Door Escutcheon
Front Panel Escutcheon for Toggle Breakers Front Panel Escutcheon for Rotary Handle, Motor Operator, or extended escutcheon Phase Barriers (set of 6) Handle Rubber Bootb Sealing Accessories DIN rail mounting kit (requires 15 mm depth on a 35 mm DIN rail)b DIN rail adapter Toggle Extensions (set of 10) b Not available in HD and HG 2P modules.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS Terminal Covers Rear Connection Removable Padlock Attachment Fixed Padlock Attachment
Table 7.83:
Door Escutcheon
Terminal Covers
Toggle Handle Drawout Short lug cover 3P Short lug cover 4P Long lug cover 3P Long lug cover 4P Standard Standard Short Long
Table 7.84:
Device
Rear Connections
H-Frame Description Poles 2 3 2 or 3 3 FactoryInstalled Termination No. S S FieldInstallable Cat. No. S37432 2x S37433e S37434 S37436 $ Price 297.00 381.00 84.00 105.00 119.00 Poles 2 3 2 or 3 3 J-Frame FactoryInstalled Termination No. S S FieldInstalled Cat. No. S37437 2x S37438e S37439d S37440 $ Price 297.00 381.00 84.00 105.00 119.00 Poles 3 4 3 3 D-Frame FactoryInstalled Termination No. S S FieldInstalled Cat. No. 32477 32478 2x 32475e 32476 32562 $ Price 848.00 1122.00 219.00 261.00 149.00
Mixed Rear Connection Kit Short rear connections (set of 2) Consisting of: Long rear connections (set of 2) Short terminal cover (3P) d For use with 3P circuit breakers only. e Price shown is for quantity one.
7-38
DE2
DE2F
Discount Schedule
Mechanical Lugs
Class 612 / Refer to Catalog 0612CT0101
Table 7.85:
J-Frame Lug
Standard Ampere Rating Optional HD, HG, HJ, HL 15150 A Al Lugs for Use with Al JD, JG, JJ, JL 150175 A or Cu Wire JD, JG, JJ, JL 200250 A JD,JG,JJ,JL HD,HG,HJ,HL Cu Lugs for Use with Cu Wire Only JD,JG,JJ,JL Control Wire Terminal for H-frame lug kit Control Wire Terminal for J-frame lug kit a See page 7-41 for terminal nuts/bus bar connections.
Table 7.86:
Field-Installable Lug Kit, Terminal Cover Included Voltage Takeoffs (set of two)
D-Frame Lugs
Wire Range
Table 7.87:
Mechanical Lug Kits for M-Frame, P-Frame and R-Frame Circuit Breakerse
Circuit Breaker Application Standard Rating 800 A 1200 A M-, P-Frame 1200 A P-Frame PG,PJ,PL PG,PJ,PL I-Line Unit Mount PJ MG, MJ, PG, PJ, PL 8001200 A 1200 A 100150 A (3) 350-600 kcmil (3) 3/0 AWG-750 kcmil 750 kcmil: compact AL only (4) 3/0 AWG-600 kcmil (1) 3/0 AWG-750 kcmil (1) 1-1/0 AWG (3) 3/0 AWG-500 kcmil (4) 3/0 AWG-500 kcmil (4) 3/0 AWG-500 kcmil Optional PG,PJ,PL,MG,MJ PG,PJ,PL,MG,MJ PG,PJ,PL PG,PJ,PL Ampere Rating 800 A 800 A 800 A 800 A 800 A Wires per Lug and Wire Range (3) 3/0 AWG-500 kcmil (4) 3/0 AWG-500 kcmil (2) 3/0 AWG-600 kcmil (2) 3/0 AWG-750 kcmil 750 kcmil: compact AL only (4) 3/0 AWG-500 kcmil Cat. No. AL800M23K AL800M23K4 AL1200P24Kb AL800P6Kb AL800P6K4b AL800P7Kb AL800P7K4b AL1200P25Kc AL1200P25K4c AL1200P6KUc AL1200P6KU4c AL1200P7KUc AL1200P7KU4c AL1200R53K AL2500RKd CU250P1Kf CU800M23K CU800M23K4 CU1200P24Kb CU1200P25Kc CU1200P25K4 CU1200R53K Lugs Per Kit 3 4 1 3 4 3 4 3 4 3 4 3 4 1 2 3 3 4 1 3 4 1 $ Price Per Kit 284.00 378.00 155.00 416.00 554.00 464.00 602.00 378.00 504.00 786.00 1038.00 1233.00 1635.00 215.00 132.00 990.00 1647.00 2190.00 569.00 4886.00 6503.00 548.00
New!
Al Lugs for AL or Cu Wire
New!
PG,PJ,PL R-Frame
P-Frame
1200 A
PG,PJ,PL
8001200 A
R-Frame 1200 A I-Line (4) 3/0 AWG-500 kcmil Does not fit onto ON end of unit-mount P-frame circuit breakers. For unit-mount circuit breaker only. All unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page 7-41. For lug with a tapped hole for control wire, add a T before the K in the catalog number (for example, AL800P6TK). This lug can only be used on low amp PJ frame breakers where the Instantaneous setting must not be turned OFF. The cables must be laced with rope per lug instructions.
DE2
Discount Schedule
7-39
Compression Lugs and Power Distribution Connectors (PDC) Class 612 / Refer to Catalog 0612CT0101
www.schneider-electric.us
Table 7.88:
PowerPact
Circuit Breakers
Dimension A (in) 1.2 2.5 1.2 2.5 1.0 1.2 0.7 1.1 Max. Lugs per Terminal 1 1 1 1 1 1 1 1 Cat. No. Lugs Per $ Price Per Kit Kit 3 3 3 3 3 3 3 3 194.00 294.00 237.00 305.00 194.00 194.00 194.00 194.00
System Range
Mounting Type
Compression Lug Kits for H-Frame and J-Frame Circuit Breakers 62 AWG Al or Cu H-frame 1/04/0 AWG Al or Cu Aluminum Compression Lug Kits 13/0 AWG Al or Cu J-frame 3/0350 kcmil Al or Cu Unit 61/0 AWG Cu H-frame 42/0 AWG Cu Copper Compression Lug Kits 61/0 AWG Cu J-frame 2/0300 kcmil Cu Compression Lug Kits for D-Frame Circuit Breakers Not Available Compression Lug Kits for M-Frame, P-Frame, and R-Frame Circuit Breakers
2/0-300 kcmil 3.7 2 4/0-500 kcmil 3.9 2 2/0-300 kcmil 4.3 2 M-, P-framec Unit 500-750 kcmil 3.7 2 4/0-500 kcmil 3.9 2 500-750 kcmil 4.3 2 P-Frame Compression Lug Kit Aluminum Compression Lug Kits 2/0-300 kcmil 3.8 4 4/0-500 kcmil 4.0 4 I-line 500-750 kcmil 4.4 4 R-frameac 2/0-300 kcmil a 8 Unit 4/0-500 kcmil a 8 500-750 kcmil a 8b 4/0-500 kcmil 3.3 2 M-, P-framec 4/0-500 kcmil Unit 3.3 2 R-Frame Compression Lug Kit Copper Compression 500-750 kcmil 3.6 2 Lug Kits 4/0-500 kcmil 3.5 4 R-framec I-Line 500-750 kcmil 3.8 4 a All unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page 7-41. b 9 lugs for 3000 A circuit breakers c Not for use on I-Line circuit breakers unless wire bending space is adequate.
YA250P3 YA300P5 YA400P3 YA400P7 YA600P5 YA800P7 YA1200R3 YA1200R5 YA1200R7 YA2000R3 YA2000R5 YA2500R7 CYA400P5 CYA600P5 CYA800P7 CYA1200R5 CYA1200R7
1 1 2 1 2 2 4 4 4 2 2 2 1 2 2 4 4
663.00 519.00 542.00 747.00 788.00 845.00 663.00 707.00 888.00 317.00 291.00 350.00 651.00 753.00 554.00 987.00 920.00
Table 7.89:
PDC6HD6 PDC6JD4
Power Distribution Connectors for H-Frame, J-Frame and D-Frame Circuit Breakers
Circuit Breaker Ampere Rating Wires Per Terminal & Wire Range Dimension A (in.) 1.0 1.2 1.0 1.5 1.28f 1.31f Cat. No. PDC6HD6 PDC3HD2 PDC6JD4 PDC3JD20 PDC5DG20 PDC12DG4 Quantity Per Kit 3 3 3 3 3 3 $ Price Per Kit 443.00 434.00 305.00 594.00 387.00 387.00
PDC3HD2
PDC3JD20
15150 (6) 146 AWG Cu HD, HG, HJ, HLd 15150 (3) 142 AWG Cu 150250 (6) 144 AWG Cu JD, JG, JJ, JLd 150250 (2) 141 and (1) 122/0 AWG Cu 150600 (3) 142 AWG and (2) 142/0 AWG DG, DJ, DL 150600 (12) 144 AWG d OFF end only when OFF end is the load end.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS PDC12P4 PDC6P20
Crimp lug or power distribution connectors extension past end of circuit breaker A See Table Extremity of Molded Case w/Mechanical Lugs A See Table
Table 7.90:
Ampere Rating Use for multiple load connections on one circuit breaker in place of standard distribution block to save space and time. Use on load end of circuit breaker only 2501200 A Use in UL508 Industrial Control applications only. Use in UL1995/CSA C22.2 No. 236 heating and cooling equipment. For Cu wire only. 2501200 A e f
Not for use with I-Line circuit breakers. Kit includes long terminal shield and cover, which adds 1.65 inches to standard lug with short terminal shield.
7-40
DE2
Discount Schedule
Table 7.92:
H-Frame Lug With Terminal Nut
Frame
Bus Bar Connections Hardware for D-Frame, M-Frame and P-Frame Circuit Breakers
Term. No. F Poles 3 4 1 Cat. No. 36966 36967 S33928 $ Price 23.70 31.50 28.50
Description Set of 3 terminal screws and washers for one side D-Frame Set of 4 terminal screws and washers for one side M- and P-Frame Bus Connector Kit for one pole, one end
Table 7.93:
Lugs per 3P Kit (One End Only) 4P Kit (One End Only) Phase Cat. No. $ Price. Cat. No. $ Price 3000 A, 100% Rated Required for cable or bus 9 RL3TB 1440.00 RL3TB4 2016.00 3000 A, Standard (80% Rated) Required for cable or bus 2500 A, 100% Rated Required for cable or bus Required for cable, optional 8 RLTB 914.00 RLTB4 1280.00 2500 A, Standard (80% Rated) for bus Required for cable, optional All Other R-Frame CIrcuit Breakers for bus Usage
For cable connection to RLTB, use AL2500RK lug. See page 7-40. Table 7.94:
Used With
2.24 1.68
1 1 1 1
M-, P-Frame S33646 47.30 Phase Barriers 3 R-Frame S33998 47.30 a Short lug shields provide IP20 protection for mechanical lugs and are compatible with control wire terminals. b J-frame terminal shield is not compatible with the YA250J35 compression terminal.
Table 7.95:
Accessory
B See Table
150 A Neutral Sensor 250 A Neutral Sensor External Neutral Sensor 400 A Neutral Sensor 600 A Neutral Sensor Spare Parts 100 Identification Labels Mini test kit (battery not included) Test Kits Portable test kit c DE5A Discount Schedule
DE2
Discount Schedule
7-41
Table 7.96:
Plug-In and Drawout Mountings for H- and J-Frame Circuit Breakers (3P or 2P in a 3P module)
Description Factory Installed Cat. No. N D HJ00 S29278 HJ00 S29278 S29282 S29283 S37442 S37443 S29273 S29274 S29275 S29284 S29287 FieldInstalled Cat. No. $ Price 638.00 1419.00 290.00 348.00 485.00 348.00 587.00 195.00 48.00 48.00 95.00 60.00 33.00 77.00 207.00
Complete Factory-Assembled Plug-in base shipped with circuit breaker Circuit Breakers Drawout cradle shipped with circuit breaker Circuit breaker Only Plug-in base kit Circuit breaker only Plug-in base kit Drawout Cradle Cradle side plates (fixed part of chassis) Circuit breaker side plates (moving part of chassis) H-Frame Shutter Kit (set of two) J-Frame Shutter Kit (set of two) Fixed part 9-wire connector (mounted on base) Secondary Disconnect Moving part 9-wire connector (mounted on Blocks circuit breaker) Support for 2-moving connectors Extended escutcheon with extended toggle handle Two position indicating switches (connected/disconnected) Plug-In Base
Table 7.97:
Description
Kit (stationary and moving parts) Stationary Part Plug-in base Fixed part of chassis
HJ00
HJ00
Moving part of chassis Moving Part Short terminal covers Power connections a Price shown is for quantity of 1. 3 4 3 4
Table 7.98:
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Secondary Disconnecting Blocks Shutters Chassis Accessories
Table 7.99:
Termination Letter N = Plug-in D = Drawout
Termination Options
For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number.
HJ00 Options Code Suffix H = Plug-in or Drawout J = No Stationary Part 0 = No Switches 0 = No Shutters
DGL36400E20
Termination No.
Table 7.100:
Drawout Cradle Cradle Connectors
Front Connected Flat (FCF) Rear Connected T Horizontal/Vertical (RCTH/RCTV) Modbus cradle communication module Safety shutters Secondary disconnects terminal shield Cradle position switch 1a/1b Form C Connected/test/disconnected Low level cradle position switch 1a/1b Form C Connected/test/disconnected Cell keying kit Disconnected position key lockingprovision for Kirk or Federal Pioneer Cradle Lock Accessories Door interlock kit Racking interior kit Door escutcheon (for replacement only, included with circuit breaker) Transparent cover Push-in terminal kit (3 wires) Push-in terminal kit (6 wires) Finger cluster Cluster grease (12 oz. tube) b Needs 2 kits per cradle. c Discount Schedule DE2F
7-42
DE2
DE2F
Discount Schedule
Power quality measurement and advanced protection features. Includes all features listed for the Micrologic power trip unit, as well as:
Table 7.101:
PowerPact P- and R-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units.
True RMS sensing LI, LSI trip configurations Field-interchangeable long-time rating plugs LED long-time pickup indication Test kits available Thermal imaging
LSIG trip configurations Digital ammeterphase and neutral (4-pole only) Phase loading bar graph LED trip indication Zone-selective interlocking (ZSI) (short-time & ground-fault) Optional Modbus communicationsPowerLogic compatible
3.0A 5.0A 6.0A 5.0P 6.0P 5.0H 6.0H LI x LSI (Instantaneous can be turned off) x x x x x x x LSIG / Ground-Fault Tripa x x x Ground-Fault Alarm (No Trip) ab x x Ground-Fault Alarm and Trip a x x Adjustable Rating Plugs x x x x x x x x x True RMS Sensing x x x x x x x x x UL Listed x x x x x x x x x Thermal Imaging x x x x x x x x x Phase Loading Bar Graph x x x x x x x LED for Long-time Pickup x x x x x x x x x LED for Trip Indication x x x x x x x Digital Ammeter x x x x x x x Zone-selective Interlocking x x x x x x x Communications o o o x x x x LCD Dot Matrix Display x x x x Advanced User Interface x x x x Protective Relay Functions x x x x Neutral Protection x x x x Contact Wear Indication x x x x Incremental Fine Tuning of Settings x x x x Selectable Long-time Delay Bands x x x x Power Measurement x x x x Power Quality Measurements x x Waveform Capture x x a Requires neutral current transformer in 34W systems. b Requires M2C or M6C Programmable Contact Module.
Features
Table 7.102:
Model
LSI trip configuration with programmable ground fault alarm LSIG (Ground-fault trip) with programmable ground fault alarm Incremental fine tuning of L, S, I, and G pickup and delay settings LCD dot matrix display and LED trip indication Advanced user interface Advanced protection IDMTLselectable long-time delay bands Neutral protection Power measurement Contact wear indication Modbus communicationsPowerLogic compatible Local and remote settings
Kit $ Price / Circuit Breaker $ Price Adder 2.0 (IEC only) LSO S132R 2920.00 3.0 (UL/ANSI only) LI None S131A 2920.00 5.0 LSI S133A 4176.00 2.0A (IEC only) LSO S142Rd 4554.00 3.0A (UL/ANSI only) LI S141Ad 4554.00 Ammeter 5.0A LSI S143Ad 5812.00 6.0A LSIG S144Ad 7418.00 5.0P LSI S163Ade 8720.00 Metering, Adv. Protection 6.0P LSIG S164Ade 10324.00 5.0H LSI S173Ade 14770.00 Metering, Adv. Protection & Harmonic Analysis 6.0H LSIG S174Ade 16374.00 c The standard rating plug supplied with a trip unit will be the A rating plug. To specify an alternative adjustable rating plug, please add the letter designation to the end of the catalog number. Please refer to page 7-44 for a complete listing of adjustable settings available with each plug. (Example: S143B would specify a B rating plug instead of the standard "A" plug.) Use suffix N if no rating plug is required, deduct $200.00 from the complete trip unit kit price. d When replacing a standard trip unit with Type A (Ammeter), P (Power metering) or H (Harmonic analysis) trip unit, order the 12-pin connector kit S33101 for the Masterpact NW and NT and the PowerPact P-frame drawout circuit breakers or kit S33100 for PowerPact P-frame and R-frame unit-mount and I-Line circuit breakers. See page 7-44. e Requires Circuit Breaker Communications Module.
DE2F
Discount Schedule
7-43
Table 7.106:
Description
Special Options
Factory-Installed Suffix Q Field-Installable Cat. No. N/A $ Price 3308.00
To provide maximum design flexibility, system protection, and field upgradeability, each Micrologic trip unit is equipped with an interchangeable long-time rating plug. Each trip unit requires an adjustable rating plug to determine the long-time pickup range of the circuit breaker. These plugs are factory installed on new trip units, or can be ordered separately for field-installable upgrades. Adjustable rating plugs are offered in eight different ranges of long-time pickup adjustments. The following chart show the ranges of adjustments. Each adjustment times the sensor rating (lr X In) of the circuit breaker sets the long-time pickup value of the circuit breaker. Table 7.103:
Adjustable Rating Plug
Rating Plug A B C D E F G H
Table 7.107:
Adjustable rating plug "A" is installed as standard on all Micrologic trip unit orders. However, an alternative selection may be specified from the "Assembled" table below, and factory installed with your trip unit order at no additional charge. To order, please attach the appropriate catalog suffix to the end of the trip unit Cat. No. (after specifying trip unit options). Adjustable rating plugs may also be purchased as field-installable components from the table below.
Full Function Test Kit
Table 7.104:
Rating Pluga A B C D E F G H a
Rating Plugs
Factory-Installed Field-Installable
Cat. No.h $ Price Hand-held Test Kit S33594 5386.00 Primary Injection Test Adaptor S33937 252.00 Full-function Test Kit S33595 33792.00 Seven-pin Test Cable (for connection between S48907 1488.00 test kit and trip unit)e Two-pin Test Cable (for connection between test S48908 784.00 kit and trip unit)f 230 Vac Filtered Power Cordg S48856 166.00 120 Vac Filtered Power Cordg S48855 61.00 Trip Unit Battery for Trip Indicator Lights S33593 438.00 Power supply with: 2430 Vdc input 685823 48/60 Vdc input 685824 125 Vdc input 685825 1238.00 New! 110130 Vac input 685826 200240 Vac input 685827 380415 Vac input 685829 Micrologic A Trip Unit Cover, clear S33592 16.00 Micrologic P/H Trip Unit Cover, opaque gray S47067 16.00 Trip Unit Seal (6 pieces) MICROTUSEAL 60.00 for compliance with NEC 240.6(c) 12-pin Trip Unit Connector for NT/NW Masterpact S33101 228.00 Circuit Breakers 12-pin Trip Unit Connector for P- and R-Frame S33100i 255.00 Circuit Breakers Battery Back-up (12 Hours) 685831 3570.00 e Used for testing Micrologic trip units. Included in the price of the Handheld/Full-function Test Kits. Kit for replacement only. f Used for testing STR trip units. Included in the price of the Handheld/Full-function Test Kits. Kit for replacement only. g Included in the price of the Full-function Test Kit. Kit for replacement only. h DE2F Discount Schedule. i DE2 Discount Schedule.
New!
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Cat. Suffix $ Price Adder Cat. No.b $ Price A (standard) N/C S48818 200.00 B N/C S48819 200.00 C N/C S48820 200.00 D N/C S48836 200.00 E N/C S48837 200.00 F N/C S48838 200.00 G N/C S48839 200.00 H N/C S48840 200.00 Long-time pickup amperes (Ir) = Sensor Rating (In) X Setting of rating plug. Fine adjustment tuning is included on Micrologic Power and Harmonic trip units, allowing for incremental settings of 1 A between the plug setting and.40 X Sensor Rating. DE2F Discount Schedule
Table 7.108:
Circuit Breaker
7
Sensor Plug
c d
Table 7.105:
S33575d P-Frame S33576d S48916d S34036d R-Frame S48896d S48182d All NCTWIRING DE2F Discount Schedule Includes NCTWIRING kit.
Table 7.106:
New!
Description
Special Options
Factory-Installed Suffix YK Field-Installable Cat. No. N/A $ Price N/C
Original Circuit Sensor Plug Sensor Plug $ Pricek Breaker Amperage Range Catalog No. 250 A 250 A S47052 1040.00 400 A 400 A S47053 1040.00 600 A 400 A S48823 1040.00 UL P-Frame 800 A 400800 A S33092 1040.00 1000 A 4001000 A S33093 1040.00 1200 A 6001200 A S33824 1040.00 630 A 630 A S48823 1040.00 800 A 600800 A S33092 1040.00 IEC P-Frame 1000 A 6001000 A S33093 1040.00 1250 A 6001250 A S33824 1040.00 1600 A 6001600 A S33095 1040.00 600 A 600 A S48823 1040.00 800 A 600800 A S33092 1040.00 1000 A 6001000 A S33093 1040.00 1200 A 6001200 A S33824 1040.00 UL R-Frame 1600 A 8001600 A S33095 1040.00 2000 A 10002000 A S33982 1040.00 2500 A 12002500 A S33983 1040.00 3000 A 12003000 A S48825 1040.00 1600 A 1600 A S33095 1040.00 2000 A 16002000 A S33982 1040.00 IEC R-Frame 2500 A 16002500 A S33983 1040.00 3200 A 16003200 A S33984 1040.00 j For use only with circuit breakers with date codes later than 07011. k DE2F Discount Schedule.
Table 7.109:
Circuit Breaker Communication Module (BCM) (Modbus) Two Programmable Contacts Module (M2C) Six Programmable Contacts Module (M6C) External Voltage Sensing (EVS)
7-44
DE2
DE2F
Discount Schedule
Full-Featured Performance
Masterpact NT
Masterpact NW
Complete product offering up to 200 k AIR without fuses Circuit breakers tested to show arc flash hazard risk category as referenced by NFPA70E 800 A to 6000 A frames, fixed and draw-out Rated for AC voltage systems through 600 V (635 V ANSI) Short-time withstand ratings up to 100 kA Cradle position indicator: connected, test and disconnected Simple, visual contact wear indicators Full complement of field-installable accessories common to all standards Four interchangeable Micrologic trip units to choose from Available PowerLogic based power metering and monitoring capabilities Available protective relay functions as defined by ANSI C37.2 and C37.90
The following charts show the Masterpact NW and NT ratings for ANSI and UL 489. See Pricing Guide 0613PL0001 and Catalog 0613CT0001.
Table 7.110:
Short-time Withstand Current (kA RMS) Built-in Instantaneous Override (kA RMS 10%) Close and latch rating (kA RMS) Tested to show the arc flash hazard risk category as referenced by NFPA70E Breaking time Closing time Sensor Rating
42 65 85 c c c
65 85 65 40
100 85 117 40 85
42 65 40
Table 7.111:
Short-time Withstand Current (kA RMS) Built-in Instantaneous Override (kA RMS 10%) Close and latch rating (kA RMS) Tested to show the arc flash hazard risk category as referenced by NFPA70E Breaking time Closing time Sensor Rating Endurance Rating (C/O Cycles) Mechanical With No Maintenance Electrical h Fixed-mounted only. i Drawout mounted only.
2530 ms with no intentional delay (9 ms for L and LF) < 50 ms 6001200 A 12,500 2800
Table 7.112:
Description Masterpact NW Remote Racking Devicea Mounting Bracket Kit for NW Remote Racking (contains 10 mounting brackets) Control Unit for NW Remote Rackingb 30 ft Control Cable for NW Remote Rackingb Drive Shaft for NW Remote Rackingb a Unit comes with 10 mounting brackets included. b For replacement only.
NWMPRRT
2009 Schneider Electric All Rights Reserved
7-45
12,500 Endurance Rating (C/O Cycles) Mechanical With No Maintenance Electrical 2800 a 24 kA RMS for 800 A circuit breaker frame with 100 A or 250 A sensor. b 65 kA RMS for 2000 A. c None except 24 kA RMS for 800 A circuit breaker frame with 100 A or 250 A sensor. d 40 kA RMS for 2000 A. e The endurance rating for 2000 A, N/H/L/LF is 10,000 for mechanical and 1000 for electrical. f 4000 A standard with circuit breaker is not available in L1 interrupting rating code or drawout construction (fixed mounting only). g Drawout mounted only.
2530 ms with no intentional delay (9 ms for L1, L1F, L and LF) 70 ms 100250 A 400800 A 20004000 A 10002000 A 16003200 A 6001200 A 25005000 A 8001600 A 10002000 A 10,000 10,000 5k 5,000 12,500e 1,000 1,000 1k 1,000 2800e
Ground-Fault Protection
GC-200 Relay
Five models with sensitivities suitable for main, feeder, or branch circuits Ten adjustable pickup settings for each model Small, non-metallic enclosure mounts on DIN rail 10 A and 5 A output contacts for trip and alarm Zone-selective interlocking (ZSI) to optimize coordinated systems I2t inverse time characteristics
Real-time display of ground-fault values Also recalls ground-fault at last trip or at maximum since reset Allows remote testing or resetting of the relay LCD back-lit display Surface mounts over panel meter cutout Fine adjust pickup settings (D and E versions only)
Sensors
Zero sequence sensing current transformers for all phases and neutral Several sizes of toroids and rectangular CTs Many are split-core or open frame for ease of installation
Table 7.113:
Ground-Fault Relay
$ Price 2960.00 2960.00 2960.00 2960.00 2960.00 948.00 96.00 158.00 302.00
GC DSP Display
Cat. No. Description Specifications GC200A 30 mA300 mA GC200B 300 mA3.0 A GC200C Ground-fault relay 3.0 A30.0 A GC200D 30.0 A300 A GC200E 120 A1200 A GCDSP Display module GC4 4 feet GC12a 12 feet Display cable GC30 30 feet One GC12 twelve foot cable is included with GCDSP display modules.
Table 7.114:
Cat. No. GC200A GC200B GC200C GC200D GC200E 0.03 0.3 3 30 120
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS T3B Toroid Sensor GT912 Rectangular Sensor
Table 7.115:
Relay Cat. No. GC200A
GC-200 Sensors
Sensor Cat. No. Type CT Ratio 700:1 Window Dimensions in 1.875 dia. 2.75 dia. 1.875 dia. 2.75 dia. 5.75 dia. 5.75 dia. 8.75 dia. 7.5 x 13.5 4.25 x 17.625 8 x 26.5 4.5. x 11 4.5 x 21 4.5 x 31 4.5 x 35 10.5 x 11 10.5 x 21 10.5 x 31 5.5 x 8.5 5.5 x 14.5 5.5 x 26.5 8.5 x 14.5 8.5 x 20.5 8.5 x 26.5 9.5 x 24 9.5 x 27 11.5 x 26.5 mm 48 dia. 70 dia. 48 dia. 70 dia. 146 dia. 146 dia. 222 dia. 191 x 343 108 x 448 203 x 674 114 x 280 114 x 534 114 x 788 114 x 890 267 x 280 267 x 514 114 x 788 140 x 216 140 x 368 140 x 673 216 x 368 216 x 521 292 x 673 241 x 610 241 x 686 292 x 673 $ Price 2046.00 2709.00 704.00 774.00 774.00 1326.00 1106.00 3063.00 3650.00 4446.00 1914.00 2255.00 2706.00 2834.00 2450.00 3075.00 4233.00 1769.00 2058.00 2766.00 2645.00 2901.00 3246.00 2844.00 3219.00 3726.00
GC200E
T2B Toroid T3B T2A Toroid T3A Toroid T6A Toroid T6AS Toroid, split-core T9A Toroid R713A R417A Rectangular R826A All "A" type sensors above, plus: RZ511 RZ521 Rectangular, Open Frame RZ531 RZ535 RZ1011 RZ1021 Rectangular, Open Frame RZ1031 GT912 GT918 Rectangular, Open Frame GT930 GT1218 GT1224 Rectangular, Open Frame GT1230 GT1327 Rectangular, Open Frame GT1330 GT1530 Rectangular, Open Frame
1000:1
1000:1 1000:1 1000:1 1000:1 1000:1 1000:1 1000:1 600:1 600:1 600:1 600:1 600:1 600:1 600:1 600:1 600:1
7-46
DE2
Discount Schedule
Ground-Fault Protection
www.schneider-electric.us
RH99M
RH10M
Instantaneous
Manual
110130 Vac
220240 Vac
30 mA 100 mA 300 mA 500 mA 1A 30 mA 100 mA 300 mA 500 mA 1A 30 mA 100 mA 300 mA 500 mA 1A 30 mAa or 300 mA (2 settings) Adjustable, (9 settings): 0.03a, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30 A
RH21M
Instantaneous or 60 msec (2 settings) Adjustable (9 settings): 0, 0.06, 0.15, 0.23, 0.31, 0.5, 0.8, 1.0, 4.5 sec
Manual
1224 Vac/1248 Vdc 110130 Vac 220240 Vac 1224 Vac/1248 Vdc 110130 Vac 220240 Vac 1224 Vac/1248 Vdc 110130 Vac 220240 Vac
56300 56302 56305 56306 56307 56320 56322 56325 56326 56327 56330 56332 56335 56336 56337 56360 56362 56363 56370TD 56372TD 56373TD 56390TD 56392TD 56393TD 56400 56402 56405 56406 56407 56420 56422 56425 56426 56427 56430 56432 56435 56436 56437 56460 56462 56463 56470TD 56472TD 56473TD 56490TD 56492TD 56493TD
1988.00
1988.00
1988.00
2363.00
Manual
2700.00
RH99M
RH99P
Automatic
2700.00
Panel Mounted 30 mA 100 mA 300 mA 500 mA 1 Amp 30 mA 100 mA 300 mA 500 mA 1 Amp 30 mA 100 mA 300 mA 500 mA 1A 30 mAa or 300 mA (2 settings)
2063.00
RH10P
Instantaneous
Manual
110130 Vac
2063.00
220240 Vac
2063.00
RH21P
Instantaneous or 60 msec (2 settings) Adjustable (9 settings): 0, 0.06, 0.15, 0.23, 0.31, 0.5, 0.8, 1.0, 4.5 sec
Manual
1224 Vac/1248 Vdc 110130 Vac 220240 Vac 1224 Vac/1248 Vdc 110130 Vac 220240 Vac 1224 Vac/1248 Vdc 110130 Vac 220240 Vac
2438.00
Manual
PA50
New!
RH99P
Automatic
2813.00
2813.00
30 mA is instantaneous only, except for RH99M and RH99P models. Their suffix TD indicates time delay at 30 mA. For models with no time delay (IEC compliant) consult catalog 0972CT0401.
Sensors
Type TA30 PA50 IA80 MA120 SA200 GA300 TA30 PA50 IA80 MA120 POAb GOAb 280 x 115 470 x 160
Maximum Currentc 65 A 85 A 160 A 250 A 400 A 630 A 65 A 85 A 160 A 250 A 85 A 250 A 1600 A 3200 A
Inside Diameter in. 1.18 1.97 3.15 4.72 7.87 11.81 0.79 1.58 2.76 4.33 1.81 4.33 11.02 x 4.53 18.50 x 6.30 mm 30 50 80 120 200 300 20 40 70 110 46 110 280 x 115 470 x 160
Cat. No. 50437 50438 50439 50440 50441 50442 56055 56056 56057 56058 50485 50486 56053 56054
$ Price 375.00 488.00 615.00 833.00 1253.00 2295.00 56.00 59.00 62.00 83.00 1718.00 3015.00 5333.00 7088.00
SA200
b c
Rectangular Sensors
POA and GOA are not UL recognized Use as a guideline for sizing wire through sensor.
DE2
Discount Schedule
7-47
Table 7.117:
Optional GFM25CT
GFM250
A shunt trip may be field-installed in the HD, HG, HJ, HL, JD, JG, JJ and JL circuit breakers. Shunt trip S29382 (12 Vdc) for circuit breaker may be factory- installed (suffix SN) or field-installed Adjustable ground-fault pickup levels Adjustable ground-fault time delays Integral ground fault push-to-test feature and ground-fault indicator All GFMs are supplied for I-Line mounting, easily convertible to unit mount by removing the I-Line brackets Optional neutral current transformer for 3-phase 4-wire applications. Refer to instructions for proper installation Zone-selective interlocking capability is standard with upstream Micrologic trip system circuit breakers. The GFM can also be zone interlocked with the GC ground-fault system by using a restraint interface module.See Supplementary Digest. 120 Vac control power is required for integral test feature. Meets NEC 230-95(c)
NOTE: Ground-fault modules cannot be used for alarming only. Table 7.118: Module/Enclosure Selection Charta
Cat. No.b GFM150HD GFM250JD I-Line Switchboard LA LA Ground-fault Pickup Adjustment Range 20100 A 40200 A GFM $ Price 4250.00 4250.00 375.00
Companion Circuit Breaker Prefix HD, HG, HJ, HL JD, JG, JJ, JL
Accessories
a b H&J GFM25CT Optional Neutral Current Transformer (required for 4-wire loads) At 250 A, the GFM250JD can be used with 80% rated circuit breakers only. See Supplemental Digest for additional GFMs.
New!
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Figure 7.1: I-Line J-Frame with ELM installed
Adjustable ground-fault pickup levels as low as 30 mA Adjustable ground-fault time delays from instantaneous to 500 msec (Time delay can be applied to the 30 mA setting) Integral ground fault push-to-test feature Ground-fault indicator (LED for local status; contacts for remote indication) All ELMs are supplied for I-Line mounting and are easily convertible to unit-mount by removing the I-Line brackets Three poles; 240 to 600 Vac maximum: 3-wire applications only (no neutral) Line-power obtained through internal bus to provide power for electronics, shunt trip, and integral test feature. A shunt trip is required in the circuit breaker; it may be field-installed or factory-installed in the PowerPact H and J circuit breakers. UL 1053 Ground-fault Sensing and Relaying Equipment
Table 7.119:
Prefix HD, HG, HJ, HL JD, JG, JJ, JL c d
At 250 A, the ELM250JD can be used with 80% rated circuit breakers only. For Factory Installation of ELM Module: For termination designation (3rd letter of catalog number) use ONLY M. Add factory installed 48 Vdc shunt trip (suffix SP) to breaker plus suffix VL or VM. SP $717. adder. Use VL for H frame $4736. adder. Use VM for J frame $4886. adder. Plus the List Price of the H or J breaker.
7-48
DE2
Discount Schedule
Thermal-magnetic molded case circuit breakers shown on pages 7-49 through 7-51 are permanent trip UL Listed, CSA Certified, IEC rated, and also meet the requirements Table 7.120:
Ampere Rating 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A
Fixed AC Magnetic Trip Hold 275 A 275 A 275 A 275 A 400 A 400 A 400 A 400 A 800 A 800 A 800 A 900 A 900 A Trip 600 A 600 A 600 A 600 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1700 A 1700 A
FAL 1P 15100 A
Table 7.121:
Ampere Rating
Fixed AC Magnetic Trip Hold 275 A 275 A 275 A 275 A 400 A 400 A 400 A 400 A 800 A 800 A 800 A 900 A 900 A Trip 600 A 600 A 600 A 600 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1700 A 1700 A
FAL/FHL 2P 15100 A
15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A
FAL/FHL 3P 15100 A
Table 7.122:
Ampere Rating 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A
Fixed AC Magnetic Trip Hold 275 A 275 A 275 A 275 A 400 A 400 A 400 A 400 A 800 A 800 A 800 A 900 A 900 A Trip 600 A 600 A 600 A 600 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1700 A 1700 A
Table 7.123:
AL50FA
AL100FA
Standard Ampere Rating Optional Ampere Rating FA, FH, FI 1530 A FA, FH, FI 35100 A FA, FH, FI 35100 A FA, FH, FI 1530 A FA, FH 15100 A FA 150 A (only) FA, FH, FI 15100 FA, FH 15100 a For use in the OFF end only, when the OFF end is the load end.
Table 7.124:
Termination Option
Termination Letter F = No Lugs L = Lugs both ends P with MT Suffix = Lugs ON end P = Lugs OFF end
For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number.
NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories.
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplemental Digest Compression and Power Distribution Connector Lugs . Supplemental Digest Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-56
FAL36100
Termination Letter
DE2
Discount Schedule
7-49
$ Price AL50FA 3296.00 144 Cu or 3296.00 124 Al 3296.00 3296.00 3296.00 3296.00 3296.00 AL100FA 3296.00 141/0 Cu 3296.00 or 121/0 Al 3296.00 3296.00 3296.00
Adjustable AC Magnetic Trip Low High 1100 A 1250 A 1500 A 1750 A 2000 A 2250 A 2500 A 1100 A 1250 A 1500 A 1750 A 2000 A 2250 A 2500 A
KAL/KHL 2P and 3P
2P, 600 Vac, 250 Vdc 110 550 A 125 625 A 150 750 A 175 875 A 200 1000 A 225 1125 A 250 1250 A 3P, 600 Vac, 250 Vdc 110 550 A 125 625 A 150 750 A 175 875 A 200 1000 A 225 1125 A 250 1250 A
Table 7.126:
KIL36250
Ampere Rating 2P, 240 Vac 250 300 350 400 3P, 240 Vac 250 300 350 400
Q4L 2P and 3P
Table 7.127:
7
Standard KI KI Q4
Table 7.128:
240 Vac 480 Vac 600 Vac
Interrupting Ratings
KAL 42 kA 25 kA 22 kA KHL 65 kA 35 kA 25 kA KIL 200 kA 200 kA 100 kA Q4 25 kA
NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories.
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplemental Digest Compression and Power Distribution Connector Lugs. Supplemental Digest Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
7-50
DE2
Discount Schedule
Table 7.129:
Ampere Rating
2P, 600 Vac, 250 Vdc 125 A 625 A 150 A 750 A 175 A 875 A 200 A 1000 A 225 A 1125 A 250 A 1250 A 300 A 1500 A 350 A 1750 A 400 A 2000 A 3P, 600 Vac, 250 Vdc 125 A 625 A 150 A 750 A 175 A 875 A 200 A 1000 A 225 A 1125 A 250 A 1250 A 300 A 1500 A 350 A 1750 A 400 A 2000 A
Table 7.130:
Ampere Rating
2P, 600 Vac 300 A 1500 A 3200 A LCL26300 7479.00 LIL26300 8604.00 350 A 1750 A 3200 A LCL26350 7479.00 LIL26350 8604.00 400 A 2000 A 3200 A LCL26400 7479.00 LIL26400 8604.00 450 A 2250 A 4200 A LCL26450 7823.00 LIL26450 12551.00 500 A 2500 A 4200 A LCL26500 7823.00 LIL26500 12551.00 600 A 3000 A 4200 A LCL26600 7823.00 LIL26600 12551.00 3P, 600 Vac 300 A 1500 A 3200 A LCL36300 8312.00 LIL36300 9563.00 350 A 1750 A 3200 A LCL36350 8312.00 LIL36350 9563.00 400 A 2000 A 3200 A LCL36400 8312.00 LIL36400 9563.00 450 A 2250 A 4200 A LCL36450 8691.00 LIL36450 13949.00 500 A 2500 A 4200 A LCL36500 8691.00 LIL36500 13949.00 600 A 3000 A 4200 A LCL36600 8691.00 LIL36600 13949.00 b Type LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits.
Table 7.131:
Standard LA, LH
AL400LA
AL600LI5
NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories.
AL400LH7
Table 7.132:
Interrupting Table
LAL LHL 65 kA 35 kA 25 kA LCL 100 kA 65 kA 35 kA LIL 200 kA 200 kA 100 kA
42 kA 30 kA 22 kA
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplemental Digest Compression and Power Distribution Connector Lugs . Supplemental Digest Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54 Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56
DE2
Discount Schedule
7-51
80% rated True RMS sensing Interchangeable rating plugs LSI, LS(I)G, trip configurations Short-time delay = I2t IN and ground-fault delay = I2t OUT Integral ground-fault testing LED long-time pickup indication Thermal & magnetic backup protection Long-time & ground-fault memory Optional local trip indicatorsoverload, short circuit, ground-fault Optional local ammeter/trip indicator Universal test set available Optional I-Line mounting (LX, LXI) Optional neutral current transformer for 4-wire systems
100% rated (600 sensor LE/LEL) circuit breakers are 80% rated) True RMS sensing Interchangeable rating plugs PowerLogic compatible LI, LIG, LS(I), LS(I)G (instantaneous OFF) configurations Short-time delay = I2t IN & I2t OUT and ground-fault delay = I2t IN & I2t OUT Short-time withstand rating Integral ground-fault testing Optional ground-fault alarm (no trip) (Requires CIM3F with PowerLogic or see Bulletin 0502DB0001.) LED long-time pickup indication Zone-selective interlocking (short-time & ground-fault) Long-time & ground-fault memory Local Trip Indicatorsoverload, short circuit, ground-fault Local ammeter/trip indicator Universal test set available Optional I-Line mounting (LE) Optional neutral current transformer for 4-wire systems
Table 7.133:
100
125
ARP050
150
ARP060
250
175
ARP070
200
ARP080
7
Circuit Breakers with Micrologic Standard-Function Trip Systems (LXL, LXIL) MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
400
225
ARP090
250
ARP100
300
ARP075
350
ARP088
400
450
600 a
500
ARP083
600 a b
ARP100
600 A sensor is 80% rated Substitute (A) in place of (G) for ground-fault alarm (pickup indication only). Requires CIM3F and Powerlogic, or see Data Bulletin 0502DB0001. No instantaneous OFF position for LI or LIG trip function type circuit breakers. c Type LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits. Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-51 Table 7.134: Interrupting Ratings Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56 LXL LEL LXIL 240 V 480 V 600 V 100 kA 65 kA 35 kA 100 kA 65 kA 35 kA 200 kA 200 kA 100 kA
NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories.
7-52
DE2
Discount Schedule
Table 7.135:
Cat. No. LE25CT2 LE4CT2 LE6CT2
Table 7.136:
Device Local Trip Indicator Kit Local Current Meter Kit/Trip Indicator
The National Electrical Code, Section 240-6(c) exception allows conductor ampere ratings equal to the selected long-time pick-up setting. The seals below can be used to restrict access to the trip unit once settings are selected. Table 7.137: Trip Unit Seals
Cat. No. TUSEAL MICROTUSEALa Package Quantity 100 6 $ Price 102.00 60.00
Description Trip Unit Seal, Series B Non-lead Trip Unit Seal (for Micrologic Trip Unit, Vigirex, etc.) a Discount schedule DE2F
Table 7.138:
Interchangeable Rating Plug Kits for all Circuit Breakers with Micrologic Series B Trip System
Cat. No. ARP040 ARP050 ARP056 ARP058 ARP060 ARP063 ARP067 ARP070 ARP075 ARP080 ARP083 ARP088 ARP090 ARP100 Sensor Multiplier Value 0.400 0.500 0.563 0.583 0.600 0.625 0.667 0.700 0.750 0.800 0.833 0.875 0.900 1.000 $ Price 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00 297.00
Table 7.139:
Description Cat. No. Universal Test Set (includes test module for Full-function and Standard-function LEL, LXL, LXIL) UTS3 Test Module for Full-function and Standard-function LEL, LXL, LXIL. (For use with existing CBTU1 CBTMB or UTS3 test set.) Replacement ribbon cable and rating plug adapter for CBTMB CBTMBRK Long-time and ground-fault Memory Reset Module (Series B Electronics) MTMB b See the Supplemental Digest for more information.
DE2
DE2F
Discount Schedule
7-53
Test Equipment for Circuit Breakers with Micrologic Series B Trip Systems b
Dimensions and Shipping Weights Miniature and Molded Case Circuit Breakers
www.schneider-electric.us
A G
A G
A G
D C
Table 7.140:
QO , QOU, Multi 9
Poles Fig. No. A
TM
Circuit Breakers
DimensionsInches B C D E 2.25 2.25 2.25 3.78 3.78 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.25 1.77 1.77 1.77 1.77 F 5.00d 5.00d 5.00f 6.78 6.78 6.78 G 0.59 1.34 2.09 2.85 4.35 0.59 1.34 2.09 0.62 1.37 2.12
B E
B E
B E
Figure 1
A G E B
Figure 2
A G
Figure 3
D C
QO, QOB
E B
Figure 4
A G A G
Figure 5
A G
B E
B E
B E
1 1 0.75 3.00a 2.31 2.91 QO, QOB 2 2 1.50 3.00a 2.31 2.91 3 3 2.25 3.00a 2.31 2.91 2 2 3.0 5.72 2.53 4.90 QOB-VH 150 A QOB-VH 110150 A 3 3 4.50 5.72 2.53 4.90 1 4 0.75 4.12b 2.31 2.91 QO-PL QO-GFI 2 5 1.50 4.12b 2.31 2.91 QO-EPD 3 5 2.25 4.12b 2.31 2.91 1 6 0.75 4.05c 2.38 2.98 QOU QYU 2 7 1.50 4.05c 2.38 2.98 Low Ampere 3 8 2.25 4.05d 2.38 2.98 1 10 0.75 4.45 2.37 2.96 QOU 2 11 1.50 4.45 2.37 2.96 High Ampere 3 12 2.25 4.45 2.37 2.96 1 13 0.71 3.19 1.73 2.76 2 14 1.42 3.19 1.73 2.76 Multi 9 C60N 3 15 2.13 3.19 1.73 2.76 4 16 2.84 3.19 1.73 2.76 QO-PLPS Power Supply 2 9 1.45 4.35 2.42 3.11 a 3570 A is 3.12 in; 80100 A 2P and 70100 A 3P are 3.50 in. b QO-PL is 4.55 in. c 80100 A 1P and 80125 A 2P are 4.45 in d 80100 A 1P and 80125 A 2P are 6.78 in. e 70100 A 4.45 in. f 70100 A is 6.78 in.
Figure 6
Figure 7
Figure 8
Figure 9 QO-PLPS
D C
Table 7.141:
Circuit Breaker Cat. No. Prefix QB, QD, QG, QJ
QB, QD, QG, QJ, Q4, FA, FI, KA, KC, KI, LA, LC, LI, LE, LX, LXI, MA Circuit Breakers
Poles 2 3 1 2 3 Fig. No. 22 23 21 22 23 DimensionsInches A 6.47 6.47 6.00 6.00 6.00 B 3.00 4.50 1.50 3.00 4.50 C 3.02 3.02 3.16 3.16 3.16 D 3.93 3.93 4.13 4.13 4.13 E g g 0.44 0.44 0.44 F 4.25 4.25 5.13 5.13 5.13 7.13 9.25 10.75 10.69 G 1.50 1.50 1.50 1.50 2.00 2.50 3.00 1.50 H 0.75 0.75 0.75 1.00
B E
B E
B E
B F
FAL, FHL
Figure 10
Figure 11
A A
Figure 12
A
FIL, KAL, KCL, 2&3 23 8.00 4.50 3.66 4.75 0.44 KHL, KIL Q4L, LAL, LHL 2&3 23 11.00 6.00 4.06 5.84 0.88 LIL, LEL, LXL, LXIL, 2 & 3 24 11.86 7.50 5.48 6.74 0.55 LCL MAL, MHL 2&3 23 14.00 9.00 4.53 6.50 1.66 g Dimensions E are 1.59 in at ON end and 0.63 in at OFF end.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
B B B B E
Table 7.142:
C60
D C
Frame Size FAL, FHL 1P FAL, FHL 2P FAL, FHL 3P
Shipping Weightsh
Approx. Shipping Weight (Lbs.) 2 3 5 8 4 7 KIL LAL, LHL LEL, LIL, LXL, LXIL, LCL Q4L MAL, MHL Frame Size Approx. Shipping Weight (Lbs.) 9 15 25 15 34
Figure 13
A
Figure 14
Figure 15
A
Figure 16
A
B E
Figure 17
E B G
Figure 18
E
Figure 19
B E C/L
Figure 20
B G HH C/L A F
C120
KAL, KHL h
D C
A F
A F
Figure 21
B G E
Figure 22
D C
Figure 23
A F
Figure 24
7-54
B G
Table 7.143:
HD, HG, HJ, HL, JD, JG, JJ, JL, DG, DJ, and DL Circuit Breakers
Dimensions Inches B 2.74 4.12 4.12 5.51 C 2.87 2.87 2.87 3.75 D 4.36 4.36 5.00 6.61 E 0.74 0.74 1.30 2.22 F 4.92 4.92 4.92 8.93 G 1.38 1.38 1.77
A E
F
D C
Circuit Breaker No. of Cat. No. Poles Fig. No. A Prefix 2 25 6.40 HD, HG, HJ, HL 3 26 6.40 JD, JG, JJ, JL 3 27 7.52 DG, DJ, DL 3 28 13.38
Figure 25
Figure 26
G B
Table 7.144:
Circuit Breaker Cat. No. Prefix ED, EG, EJ ED, EG, EJ ED, EG, EJ GJ
D A E F C
Table 7.145:
Circuit Breaker Cat. No. Prefix MG, MJ (800 A and below) PG, PJ, PK, PL (10001200 A) RG, RJ, RL
Figure 27
G
A F
Table 7.146:
Frame Size
Shipping Weightsa
Approx. Shipping Weight (Lbs.) 14 3 34 32 52
C D
Figure 28
Approx. Shipping Frame Size Weight (Lbs.) HD, HG, HJ, HL 2P 4 DG, DJ, DL HD, HG, HJ, HL 3P 5 GJ JD, JG, JJ, JL 5 MG, MJ ED, EG, EJ 1P 2 PG, PJ, PL ED, EG, EJ 2P 3 RG, RJ, RL (Without RLTB) ED, EG, EJ 3P 4 a All weights are for 3P circuit breakers unless otherwise noted.
Figure 29
Figure 30
Figure 31
B G
C D
D C
A D
AF
Figure 32
Figure 33
B G F D C
AE
Figure 34
7-55
Enclosures
Class 610
www.schneider-electric.us
Circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment except as footnoted. The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted. Circuit breakers are ordered and shipped separately for field installationsee pages 7-49 through 7-52. For enclosure accessories and dimensions refer to page 7-58. See Supplemental Digest Section 3 for NEMA 7 and 9 enclosures.
Table 7.147:
FA100S
QBL, QDL, QGL, QJL HDL, HGL, HJL, HLL JDL, JGL, JJL, JLL HDL JDL LAL, LHL, Q4L LAL MGL, MJL, PGL, PJL, PKL, PLL PGL, PJL, PKL, PLLh
New! New!
FA100RB
FA100DS
FAL, FHL, FCL 15100 A 1, 2, 3 FA100DS 1431.00 FA100A 351.00 HDL, HGL, HJL, HLL 15150 A 2, 3 J250DSpqr 3405.00 J250AWKpqr 582.00 JDL, JGL,J JL, JLL 150250 A 2, 3 KILe, KCL 110250 A 2, 3 IK250DS 5238.00 IK250AWK 878.00 LAL, LHL, Q4L 125400 A 2, 3 LA400DS 5673.00 LA400AWK 903.00 LELf, LXL, LXIL 100600 A 3 LX600AWK 3728.00 LCL, LIL 300600 A 2, 3 LX600AWK 3728.00 MGL, MJL, PGL, PJL, 300800 2, 3 M800DSk 10125.00 M800AWKk 2459.00 PKL, PLL PGL, PJL, PKL, PLLh 6001200 2, 3 P1200AWKk 5700.00 a Enclosures with NRB or RB suffix have provisions for 3/4 in. through 2-1/2 in. bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require field cut opening. For details and hub catalog numbers see page 3-9. b Not CSA Certified. c Suitable for rainproof NEMA 3R application by removing drain screw from bottom endwall. d When using a CT in the M800S and R enclosure the unit will no longer accommodate a 200% neutral solution. e Short circuit rating is 100 k AIR at 480 Vac maximum. f LEL 100% rated circuit breaker except for 600 A sensor. g DE2A Discount Schedule. h Accepts MGL or MJL standard rated (80%) breakers. Accepts PGL, PJL or PLL breakers 80% or 100% rated breakers, 800A maximum. i CE certified per IEC60439-1, IP20D, PE type TN-C or TN-S j CE certified per IEC60439-1, IP24D, PE type TN-C or TN-S k CE certified per IEC60439-1, IP56, PE type TN-C or TN-S l Copper wire only. m Maximum short circuit rating is 25 kAIR, 240 Vac. n Maximum short circuit rating is 18 kAIR, 480 Vac and 240 Vac. o Order service ground kit PKOGTA2 if required. p Accepts standard rated 80% breakers. Not rated at 100%. q Maximum short circuit rating is 25 kAIR at 600 Vac, 65 kAIR at 480 Vac, 125 kAIR at 240 Vac. r Earth Leakage Module is not compatible with these enclosures.
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
UL Listed Only Use 500 Vdc or 250 Vdc rated circuit breakers only.
Table 7.149:
Enclosures for Walking Beam Manually Operated Mechanical Interlock Circuit Breakers (UL Listed)a
Circuit Breaker NEMA 1 Surfaceb NEMA 3R bc
a b c
Cat. No. Ampere Enclosure Enclosure Poles $ Price $ Price Prefix...Suffix Rating Cat. No. Cat. No. FAL...WB, FHL...WB 15250 A 2, 3 KA250SWB 1040.00 KA250RWB 1827.00 Catalog number in table is enclosure only. For complete installation, the following must be ordered separately: WB Circuit Breakers (qty. 2, Supplemental Digest), Walking Beam Assembly (Supplemental Digest), Mounting Pan (Supplemental Digest), Neutral (page 7-56) and Service Ground Kit (page 7-58). Enclosure has blank top endwall. For applications above 200 A requiring a neutral, use copper wire only.
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-58 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-58 Q-frame Circuit Breaker Enclosures . . . . . . . . . . . . . . . . . . . . . . . . Page 1-22
7-56
DE1
DE2A
Discount Schedule
Specify circuit breaker catalog number: (ex: KAL36225G) Specify enclosure type (NEMA 1, 3R) Ground-fault modules are available factory installed. See table below for pricing and availability.
Table 7.151:
Price includes 3P circuit breaker, GFM, neutral assembly and neutral CT factory assembled in specified enclosure Not UL Listed.
Specify circuit breaker catalog numbers Specify manually or electrically operated (electrically operated factory installed only) Specify enclosure type (NEMA 1 or 3R) Specify if neutrals are required. (Same price)
Table 7.150:
Circuit Breaker Cat. No. Prefix (Standard ThermalMagnetic Only) FAL240 V 100 A FAL480 V 100 A FAL600 V 100 A FHL600 V 100 A LAL600 V 400 A
NOTE: Contact local Field Office for catalog number prior to quoting or placing an order.
DE1
Discount Schedule
7-57
LHL600 V 400 A 17067.00 19598.00 25760.00 28289.00 a Price includes (2) walking beam 3P circuit breakers, walking beam operator and mounting pan, (2) neutrals (if specified), and (2) motor operators (if specified) factory assembled in specified enclosure. b Not available factory assembled. Refer to page 7-56 for merchandise enclosure.
Table 7.152:
Circuit Breaker Cat. No. Prefix FAL, FHL, FCL FAL, FHL, FIL HDL,HGL,HJL,HLL HDL,HGL,HJL,HLL JDL,JGL,JJL,JLL
KIL, KCL
FAL...WB, FHL...WB LAL, LHL, Q4L LAL, LHL, Q4L, LCL, LIL LXL, LXIL LCL, LIL, LXL b, LXIL b LCL, LXL LIL, LXIL, LEL LCL, LXLb, LIL, LXILb, LELb
1000d SN1000MA 365.00 (6) 3/0500 Al/Cu, plus (1) 14/0 Al/Cu MGL, MJLe 300800 A AL800SN 365.00 AL800SN 365.00 AL800SN 365.00 (6) 3/0500 Al/Cu, plus (2) 6250 Al/Cu PGL, PJL, PKL, PLLf 2501200 A SN1200 1034.00 SN1200 1034.00 (8) 750 Max. Al/Cu, plus (2) 350 Max. Al/Cu a For applications above 200 A requiring a neutral, use copper wire only. b When using MXL, MEL, LXL, LEL or LXIL circuit breaker with integral ground fault protection on a 34W system, neutral assembly SN1000MA or SNC800LX must be used for neutral CT. Order neutral CT separately. c All Cu neutral assembly. d Rated maximum 900 A when used with Al wire. e For NEMA 1 and 3R 200% neutral applications order Jumper kit SN800SNI and 2 of kit SN1200. (No 200% neutral is available for NEMA 4X or 12 devices.) f For applications with integral ground fault protection order Neutral Mounting Kit S33576MK and Neutral CT S33576 (4001200 A only).
Table 7.153:
H H
QBL, QDL, QGL, QJL FAL, FHL, FCL, FIL, FAL...WB, FHL...WB PKOGTA2g KCL, KIL, LAL, LHL, Q4L W HDL,HGL,HJL,HLL,JDL,JGL,JJL,JLL PKOGTJ250 D W WB enclosure uses 2 circuit breakers LCL, LEL, LIL, LXL, LXIL MGL, MJL PKOGTA4 NEMA Type 1 PGL, PJL, PKL, PLL Q2, FA, J, KA...SWB, g Quantity (2) may be required for some wire installation. LA, MA, MG, PG
7
MINIATURE AND MOLDED CASE CIRCUIT BREAKERS
Table 7.154:
H
Dimensions
Approximate Dimension Approximate Dimension D mm 232 232 251 226 219 353 353 200.7 391 365 368 247 247 226.1 483 483 in. 4.88 4.88 4.13 4.88 4.13 7.50 7.50 4.75 6.00 6.00 6.28 7.94 7.94 5.50 5.63 7.12 mm 124 124 105 124 105 191 191 120.7 152 152 160 202 202 139.7 143 181 Cat. No. LA400AWK LA400DS LA400F LA400R LA400S LA400LS M800S M800R M800DS M800AWK P1200S P1200R P1200AWK Q22200NRB Q22200NS Q23225NF Q23225NRB Q23225NS Series E2 E2 E2 E2 E2 A1 A1 A1 A1 A1 A1 A1 A1 E3 E3 E3 E3 E3 H in. 42.25 42.25 45.63 44.00 44.50 27.40 40-3/8 40-3/8 40-7/8 40-7/8 52-1/8 52-1/8 53 23.38 23.13 26.25 26.25 26.25 mm in. 1073 13.75 1073 13.75 1159 16.50 1118 15.38 1130 15.38 696.0 15.40 1025.52 21 1025.52 21 1036.96 20-3/4 1036.96 20-3/4 1323.98 21 1323.98 21 1346.20 20-3/4 594 7.63 588 7.63 667 9.88 667 9.88 667 9.88 W mm 349 349 419 391 391 391.2 533.4 533.4 527.05 527.05 533.4 533.4 527.05 194 194 251 251 251 in. 7.25 7.25 6.50 7.88 6.50 6.625 9-3/4 9-3/4 9-1/2 9-1/2 9-3/4 9-3/4 9-1/2 4.75 4.25 4.75 5.50 4.75 D mm 184 184 165 200 165 168.3 247.65 247.65 241.3 241.3 247.65 247.65 241.3 121 108 121 140 121 H in. 19.50 19.50 19.50 18.00 18.13 42.25 42.25 17.00 32.40 31.36 31.05 32.26 32.26 26.40 20.00 20.25 mm 495 495 495 457 461 1073 1073 431.8 823 797 789 819 819 670.6 508 514 in. 9.13 9.13 9.88 8.88 8.63 13.88 13.88 7.90 15.40 14.36 14.47 9.72 9.72 8.90 19.00 19.00 W
Cat. No.
FA100A, AWK FA100DS FA100F W D WB enclosure uses 2 circuit breakers FA100RB NEMA Type 3R FA100S Q2, FA, LA, MA, J, MG, PG IK250AWK KA...RWB (uses side hinge cover) IK250DS HD100S J250F J250S J250R J250DS H J250AWK JD250S KA250SWB KA250RWB
W D
NEMA Type 4, 4X, 5, 12, 12K IK, FA, J, LA, LX, MA, MG, PG
7-58
DE1
Discount Schedule
Table of Contents
Section 8
Operator Mechanisms and Disconnect Switches
Door-Mounted Switches and Circuit Breaker Mechanisms
Motor Disconnect Switches IEC Style Disconnect Switches NEMA Style Disconnect Switches Circuit Breaker Mechanisms
UL 508 Motor Disconnect Switch (p.8-2 ) UL 98 Fusible Switch (p. 8-6)
9422T
30400 A
8-16 8-20
8-1
The Mini-Vario and Vario motor disconnect switch catalog numbers can be identified as described in Table 8.1.
Table 8.1:
Identification System
V CF N12 GE
Model (V-Vario, K-Operator) Operator Type/ Accessory Designation CD Single hole Red & Yellow CF Four hole Red & Yellow Single hole Red & Yellow w/extension CCD shaft Four hole Red & Yellow w/ extension CCF shaft Blank No operator or accessory Switch Typea Blank N12 Mini-Vario 10/12 A N20 Mini-Vario 16/20 A 02 Vario 10/12 A 01 Vario 16/20 A 0 Vario 20/25 A Enclosure Type (if applicable) Blank No Enclosure Mini-Vario IP55 GE Non-Metallic a Switches/contacts are dual rated (UL/IEC).
VCFN12GE
BD BF VE VD Z 1 2 3 4 5 6
Single hole Black & Gray Four hole Black and Gray Switch with Red handle installed on unit (one padlock only) Switch with Black handle installed on unit (no padlock provision) Accessory, power pole, neutral or ground Vario 20/32 A Vario 25/40 A Vario 45/63 A Vario 63/80 A Vario 100/125 A Vario 115/175 A
VN12
G30, A30, W30 Type 1/12/4/4X Metallic (Class 9421) GU Vario IP55 Non-Metallic
Mini-Vario
Table 8.2:
Current Rating
Assembled SwitchesIP65
Complete Switches for Door Mounting (3-Padlock) Red/Yellow (Single Hole) Black/Gray (Single Hole) Catalog Number VBDN12 VBDN20 $ Price 90.00 135.00 Complete Switches for Rear Mounting, Includes Extension Shaft (3-Padlock) Red/Yellow (Single Hole) Catalog Number VCCDN12 VCCDN20 $ Price 134.00 161.00
VN12/KCC1YZ
UL/IEC 10/12 A 16/20 A
Table 8.3:
Enclosed Switches
Table 8.5:
Catalog Number KCC1YZ KCD1PZ KAD1PZ VZN17 VZN30 KZ32 KZ83
Complete Switches Mounted in IP55 Non-metallic Enclosure Red/Yellow Mounted In Sealable Enclosure, Non-UL Listed Catalog Number VCFN12GE VCFN20GE $ Price 179.00 189.00
VBDN12
Table 8.4:
Catalog Number VN12a VN20a VZN12a VZN20a
Component Parts
Description $ Price 52.00 63.00 26.00 31.50 29.30 29.30 27.00 27.00 5.90 7.70
10/12 A switch only 16/20 A switch only Add on power pole for 10/12 A switch Add on power pole for 16/20 A switch Neutral Pole with early make, late break for VN12 or VZN11 VN20 switch VZN14 Grounding module for VN12 or VN20 VZN05 N.O. late make auxiliary contactb VZN06 N.C. early break auxiliary contactb VZN26 Single-pole shroud for auxiliary contacts VZN08 Three-pole shroud for VN12 or VN20 a Switches/contacts are dual rated (UL/IEC). b Auxiliary contacts are dual rated (UL/IEC 10/12 A).
8
8-2
VCCDN20
CP1
Discount Schedule
Vario
Table 8.6:
Operator Style UL/IEC 10/12 A 16/20 A 20/25 A 20/32 A 25/40 A 45/63 A 63/80 A 100/125 A 115/75 A
Table 8.7:
Operator Style
Red/Yellow (Four Hole) Red/Yellow (Single Hole) Red/Yellow (1-Padlock) Black/Gray (No-Padlock)
UL/IEC Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. 10/12 A VCCF02 162.00 VCCD02 162.00 16/20 A VCCF01 185.00 VCCD01 185.00 20/25 A VCCF0 197.00 VCCD0 197.00 VVE0 149.00 VVD0 20/32 A VCCF1 206.00 VCCD1 206.00 VVE1 156.00 VVD1 25/40 A VCCF2 252.00 VCCD2 252.00 VVE2 180.00 VVD2 45/63 A VCCF3 320.00 VVE3 212.00 VVD3 63/80 A VCCF4 356.00 VVE4 300.00 VVD4 100/125 A VCCF5 464.00 115/75 A VCCF6 606.00 a Complete switch includes handle operator, shaft, door interlock plate, and line terminal shroud.
Non-Metallic Enclosure
Metallic Enclosure
The Vario Motor Disconnect Switch is also offered as an enclosed switch, which is made of corrosion resistant material. The 3-pole version makes the Vario switch ideal for manual motor control applications. They are compact, easy to wire and connect, and come undrilled to allow variable cable entry positions. Note: VCGU enclosures are UL approved. Table 8.8:
Ampere Size UL/IEC
.31
8
6.88
175
5.38
137
5.63
143
4.25
108
a b
IP55-PVC 3-Pole, NEMA Type 1 & 12 Catalog No. $ Price 20/32 VC1GU 239.00 25/40 VC2GU 287.00 45/63 VC3GU 345.00 63/80 VC4GU 381.00 100/125 VC5GU 548.00 115/175 VC6GU 845.00 Assembled, includes switches mounted in enclosure with handle. Refer to Table 8.11 and Table 8.12 for horsepower ratings.
5.88
149
3.00
76
The V1 and V2 come in metallic enclosures (NEMA Type 1, 4, 4X, and 12). The NEMA Type 1 is supplied with conduit knockouts top and bottom. A VZ7 auxiliary contact can be factory installed in these metallic enclosures by adding Form X11 to the catalog number. A VZ20 auxiliary contact can be factory installed in these enclosures by adding Form X20 to the catalog number. Price Adder $42.00 Table 8.9: Metallic Enclosed Switches a b
Horsepower Ratings 240 V 480 V 600 V NEMA Type 1 Catalog No. NEMA Type 12 $ Price NEMA Type 4/4Xb Catalog No. $ Price $ Price Catalog No.
7.38
187
6.75
171
5.50
140
4.50
114
6.25
159
20/32 5 10 10 9421V1G30 333.00 9421V1A30 548.00 9421V1W30 783.00 25/40 5 10 15 9421V2G30 381.00 9421V2A30 594.00 9421V2W30 831.00 a Assembled, includes: switches mounted in enclosure with handle. b For indoor use only. The NEMA 4/4X enclosure is made of #304 stainless steel with 3/4 in. T&B stainless steel hubs on the top and bottom.
Catalog No. a
.25
6.2
in. VC1GUVC2GU 3 6.7 VC3GUVC4GU 3 6.7 VC5GUVC6GU 3 11.0 a UL Rated, NEMA Type 1, 12, IP55.
Table 8.11:
d a
e b
c f
VC1GUVC6GU
CP1
Discount Schedule
8-3
Table 8.10:
240 V 2 3 5 5 5 10 15 25 30
480 V 5 7.5 10 10 10 20 30 50 50
600 V 5 7.5 10 10 15 30 40 50 60
Switch Bodya
Shaft Size mm 3 Pole Switch Body
Type $ Price 10/12 6 V02 62.00 16/20 6 V01 74.00 20/25 6 V0 84.00 20/32 6 V1 95.00 25/40 6 V2 143.00 45/63 8 V3 179.00 63/80 8 V4 215.00 100/125 8 V5 287.00 115/175 8 V6 428.00 a Refer to Table 8.11 and Table 8.12 for horsepower ratings.
Table 8.14:
Operator Type
Single-Hole Operator
KAE1BZ 39.20 Black/Gray Four Hole 60 x 60 mm KBF1PZ KBF2PZ KAF1PZ KAF2PZ 39.20 39.20 39.20 39.20
KDD1PZ 39.20 KDF1PZ 39.20 KBD1PZ KDF2PZ 39.20 KCD1PZ 39.20 KCF1PZ 39.20 KAD1PZ KCF2PZ 39.20 Red/Yellow Four Hole Black/Gray Four Hole Operator Type 90 x 90 mm 90 x 90 mm V5V6 0 KDF3PZ 107.00 KBF3PZ 107.00 V5V6 3 KCF3PZ 107.00 KAF3PZ 107.00 a When using these handles for replacements on the non-metallic enclosed switches (see page 8-3), the handle shaft supplied with the enclosure must be reused.
0 0 3 3
Table 8.15:
Four-Hole Operator (All except KDF3PZ and KBF3PZ)
KCD1YZ 39.20 KCF1YZ 39.20 KADIXZ KCF2YZ 39.20 Red/Yellow Four Hole Black/Gray Four Hole Operator Type 90 x 90 mm 90 x 90 mm V5V6 3 KCG2YZ 72.00 KAG2XZ 72.00 a When using these handles for replacements on the non-metallic enclosed switches (see page 8-3), the handle shaft supplied with the enclosure must be reused.
Table 8.16:
Four-Hole Operator KDF3PZ and KBF3PZ
Catalog No. KZ65 KZ66 KZ62 KZ67
3
Gasket Kits
Description 45 x 45 mm Gasket for V02-V2 for 4-hole type handles (order in quantities of 5)IP65 60 x 60 mm Gasket for V02-V2 for 4-hole type handles (order in quantities of 5) 60 x 60 mm Gasket for V3-V4 for 4-hole type handles (order in quantities of 5) 90 x 90 mm Gasket for V5-V6 for 4-hole type handles (order in quantities of 5)IP65
5.5 13
5.5 13
12.7
48
68
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
22.5
48
68
The door interlock plate included with VCC Kits has the same drilling as the handle operators.
Table 8.17:
Type
Shaft Extension VZ17 VZ30 VZ18 VZ31 VZ18 VZ31 in. 5.513.0 5.516.9 5.512.6 5.516.5 6.513.8 6.517.7
1.5-6
c d in. mm
b dia. d c
V02 to V2 V3 to V4 V5 to V6
1.73
3.9 100 0.28 7.0
44
8-4
CP1
Discount Schedule
1.5-6
.512 .217
5.5 c 1.89 48 13
.512 .217
5.5 13
2.68
68
1.89 1.73
44 a b 48
2.68
68
in. mm V02 to V2a 2.83 72 V02 to V2 2.36 60 V3 to V4 2.56 65 V5 to V6 3.54 90 a Dimensions for single-hole mounting.
Table 8.19:
Switch Type V02 to V2 V3, V4 V5, V6 V02 to V2 V3, V4 V5, V6
Table 8.20:
Switch Type V02 to V2 V3, V4 V5, V6
Accessories
Line Side Terminal Shroud For Main Switch VZ8 VZ9 VZ10 $ Price 8.40 8.40 12.00 Terminal Shroud for Add-on Power Pole VZ26 VZ27 VZ28 $ Price 5.90 5.90 9.50 Terminal Shroud for Auxiliary Contact VZ29 VZ29 VZ29 $ Price 5.90 5.90 5.90
Table 8.21:
Switch Type
a b
V02 VZ02 VZ02 V01 VZ01 VZ01 V0 VZ0 VZ0 V1 VZ1 VZ1 V2 VZ2 VZ2 V3 VZ3 VZ3 V4 VZ4 VZ4 V5 V6 Early Break, Late Make. Auxiliary contacts are rated UL/IEC 10/12 A.
VZ7b
VZ20b
42.80
Table 8.22:
Switch Type V02V2 V3V4 V5V6
Neutral Modules Early Make/Late Break Catalog No. VZ11 VZ12 VZ13
$ Price Catalog No. $ Price Catalog No. Description $ Price 42.80 VZ14 42.80 VZ7 1 Late Make N.O. & 1 Early Break N.C. 42.80 54.00 VZ15 54.00 VZ20 2 N.O. Contacts 42.80 70.00 VZ16 70.00
Table 8.23:
Size 45 x 45 mm 60 x 60 mm 90 x 90 mm
Labeling Accessories
Nameplate Holder Only Catalog No. KZ14 KZ16 KZ101 $ Price 4.40 4.40 6.80 Use With KZ14 KZ16 KZ1010 Nameplate Only Catalog No. KZ76 KZ77 KZ100 $ Price 3.50 3.50 3.50 Catalog No. KZ13 KZ15 KZ103 $ Price 4.80 4.80 7.80
Table 8.24:
Switch Type
Shrouds
3-Pole Shroud Catalog No. VZ8 VZ9 VZ10 $ Price 8.40 8.40 12.00 Single-Pole Shroud For Add-On Power Pole VZ02-VZ2, VZ11 & VZ14 VZ23, VZ4, VZ12 & VZ15 VZ13 & VZ16 For 2-Pole Aux. Contact Catalog No. VZ26 VZ27 VZ28 VZ29 $ Price 5.90 6.90 9.50 5.90
Table 8.25:
b
Switch Type V02 to VZ2 VZ3 to VZ4
CP1
Discount Schedule
8-5
Identification System
The GS1 part numbers can be identified as follows: (See Catalog 9421CT0301 for specific applications.) Model GS1, GS2Fusible (Class J Fuse unless noted), LK3, LK4Non-Fusible Current Range, Operator Style (Front Operator unless noted), Accessory Type D30 A Front and Side Operation, DD30 A Class CC Front and Side Operation E30 A, EE30 A Class CC, G60 A, J100 A, M200 A, Q400 A, S600 A, T800 A (Class L if Fused), U1000 A, W1200 A UL Certification PolesNumber of Poles 2 or 3 AHHandle, AHTHandle w/ Test, AEExtension Shaft, ADAux contact holder, AMAux Contact GS1 D U 3
Note: All fusible switches through 400 A and non-fused switches through 200 A are equipped with a feature to test optional auxiliary contacts without energizing the load when the appropriate GS1AHT*** handle is used.
Table 8.26:
Catalog Number
Switches Fusible
Description $ Price
Table 8.28:
Catalog Number
Switches Non-Fusible
Description $ Price
Compact GS1 Fusible IEC Style Disconnect Switches GS1DDU3 30 A, 3-Pole, Class CC, use 5 x 5 Shaft GS1DU3 30 A, 3-Pole, Class J, use 5 x 5 Shaft GS2 Fusible IEC Style Disconnect Switches GS2EEU3 30 A, 3-Pole, Class CC , use 10 x 10 Shaft GS2EU3 30 A, 3-Pole, Class J, use 10 x 10 Shaft GS2GU3 60 A, 3-Pole, Class J, use 10 x 10 Shaft GS2JU3ab 100 A, 3-Pole, Class J, use 10 x 10 Shaft GS2MU3ab 200 A, 3-Pole, Class J, use 10 x 10 Shaft GS2QU3ab 400 A, 3-Pole, Class J, use 10 x 10 Shaft GS2SU3ab 600 A, 3-Pole, Class J, use 15 x 12 Shaft GS2TU3ab 800 A, 3-Pole, Class L, use 15 x 12 Shaft
237.00 260.00
Compact LK3 Non-Fusible IEC Style Disconnect Switches LK3/LK4DU3 30 A, 3-Pole, 5 x 5 Shaft LK4 Non-Fusible IEC Style Disconnect Switches LK4GU3 60 A, 3-Pole, use 10 x 10 Shaft LK4JU3 100 A, 3-Pole, use 10 x 10 Shaft LK4MU3ab 200 A, 3-Pole, use 10 x 10 Shaft LK4QU3ab 400 A, 3-Pole, use 15 x 15 Shaft LK3SU3ab 600 A, 3-Pole, use 15 x 12 Shaft LK3TU3ab 800 A, 3-Pole, use 15 x 12 Shaft LK3UU3ab 1000 A, 3-Pole, use 15 x 12 Shaft LK3WU3ab 1200 A, 3-Pole, use 15 x 12 Shaft
218.00
Table 8.27:
Catalog Number
Switches with Direct Mount Side Handle GS1EERU20 30 A, 2-Pole, Class CC 204.00 GS1EERU30 30 A, 3-Pole, Class CC 242.00 Right Side Handle for GS1AH01 46.40 GS1EERU20 & GS1EERU30 a Shipped with line side terminal shrouds, for additional shrouds see page 8-8. b Terminal lug must be ordered separatelysee page 8-8.
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES 600 A LK3SU3 Shaft 200 mm GS2AE5 Black Handle GS2AH150 Lugs Kit GS1AW503
For example: LK3SU3 (600 A Non-Fusible Switch, use 15 x 12 Shaft) + GS2AE6 (15 x 12 200 mm Type S Shaft) + GS2AH150 (Black/ Black, Lockable)
To add auxiliary contacts: For front mounted contacts order LK3AD30 (front mounted auxiliary contact holder) + GS2AM110 (N.O. contact for GS1AD10, GS2AD11, and LK3AD30).
8-6
CP1
Discount Schedule
Type D Alternate Handles for Compact Switches Only Economical Handle Design Compact Shaft Kits GS1AH101 GS1AH102
Handles
Table 8.29:
NEMA/UL Type 1, 12 1, 12
Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type D (as listed below)
IEC Type IP54 IP54 Defeatable Yes Yes Padlockable Yes Yes Color Black Red/Yellow Operation Off/On (O/I) Off/On (O/I) Catalog No. GS1AH101 GS1AH102 $ Price 51.00 51.00
Table 8.30:
Pistol Handles for Compact and Standard GS1/GS2 and LK3/LK4 for Compact GS1, 30 A, and Compact LK3 30 A (3 in. handles) for Use with Shaft Type S (as listed below)
IEC Type IP54 IP54 IP54 IP54 IP65 IP65 IP65 IP65 Defeatable Yes Yes Yes Yes Yes Yes Yes Yes Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Operation Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Catalog No. GS2AH110 GS2AH120 GS2AHT110 GS2AHT120 GS2AH410 GS2AH420 GS2AHT410 GS2AHT420 $ Price 62.00 62.00 117.00 117.00 70.00 70.00 117.00 117.00
GS1AE7/AE71 Shafts
NEMA/UL Type 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12
Table 8.31:
Use these shaft kits when using Compact Switches GS2AH110 GS2AH120
NEMA/UL Type
Pistol Handles for Standard GS2 and LK4 (as listed below)
IEC Type Defeatable Padlockable Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Operation Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Catalog No. GS2AH110 GS2AH120 GS2AHT110 GS2AHT120 GS2AH410 GS2AH420 GS2AHT410 GS2AHT420 GS2AH130 GS2AH140 GS2AHT130 GS2AHT140 GS2AH430 GS2AH440 GS2AHT430 GS2AHT440 $ Price 62.00 62.00 117.00 117.00 70.00 70.00 117.00 117.00 70.00 70.00 125.00 125.00 78.00 78.00 132.00 132.00
GS2AE8/AE81 Shafts
GS2 30100 A and LK4 60100 A (3 in. handles) 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes GS2 200400 A and LK4 200 A (5 in. handles) 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes
Table 8.32:
NEMA/UL Type
Pistol Handles for Use with Shaft Type S (as listed below)
IEC Type Defeatable Padlockable Color Operation Off/On (O/I) Off/On (O/I) Off/On (O/I) Off/On (O/I) Catalog No. GS2AH150 GS2AH160 GS2AH150 GS2AH160 $ Price 263.00 263.00 263.00 263.00
GS2AH110
GS2AH120
For LK3 4001200 A 1, 3R, 4, 4X, 12 IP65 Yes Yes Black 1, 3R, 4, 4X, 12 IP65 Yes Yes Red/Yellow For GS2 600800 A 1, 3R, 4, 4X, 12 IP65 Yes Yes Black 1, 3R, 4, 4X, 12 IP65 Yes Yes Red/Yellow Note: Now UL approved for indoor or outdoor applications.
Table 8.33:
in.
Shafts
Length mm Catalog No. $ Price
Shaft 5 mm x 5 mmfor Use with Pistol Handles, Type D 12.6 15.7 320 400 GS1AE7 GS1AE71 18.60 23.30
GS2AH160
GS2AE5 / AE51
12.6 15.7
320 400
GS2AE8 GS2AE81
18.60 23.30
12.6 15.7
320 400
GS2AE2 GS2AE21
20.30 25.00
GS2AE2/AE21 Shafts
7.9 15.7
200 400
GS2AE5 GS2AE51
32.60 40.40
CP1
Discount Schedule
8-7
Accessories
Table 8.34:
Type For Compact LK3 / GS1 Contact holder (for 5 to 8 auxiliary contacts). Standard products allow GS1AD10 46.70 up to 4 auxiliary contacts without any extra contact holders. 10 A 1 N.O. Contact Block GS2AM110 14.70 600 Vac 1 N.C. Contact Block GS2AM101 14.70 For LK4 60200 A, GS2 30800 A U = Upper or Top mounted Contact holder required (for 1 to 8 upper auxiliary contacts) GS2AD11 46.70 10 A 1 N.O. Contact Block GS2AM110 14.70 600 Vac 1 N.C. Contact Block GS2AM101 14.70 1 N.O. & N.C. Contact Block (max of two blocks any mix) GS1AN11 78.00 S = Side mounted a 2 N.O. & N.C. Contact Block (max of two blocks any mix) GS1AN22 140.00 1 N.O. & N.C. Contact Block w/ Test (max of two blocks any mix) GS1ANT11 93.00 S = Side mounted a 2 N.O. & N.C. Contact Block w/ Test (max of two blocks any mix) GS1ANT22 156.00 For LK3 4001200 A U = Upper or Top mounted Contact holder (for 1 to 4 auxiliary contacts) LK3AD30 46.70 10 A 1 N.O. Contact Block GS2AM110 14.70 600 Vac 1 N.C. Contact Block GS2AM101 14.70 a GS1AN contact blocks cannot be mixed with GS1ANT contact blocks on the same switch. You must use all GS1AN11/GS1AN22 on a single switch OR all GS1ANT11/GS1ANT22 on a single switch. U = Upper or Top mounted
Auxiliary Contacts
Description Catalog No. $ Price
GS1AD10 + GS2AM110
GS2AM110 + GS2AM101
Table 8.35:
For use on
Terminal Lugs
Wire Size # of Wires per Lug 1 1 1 1 1 1 1 Wire Type Lugs per Kit Catalog No. $ Price
Compact GS1/LK3 #14#10 Cu Standard GS2 30 A CC #14#10 Cu Standard GS2 30 A J #14#10 Cu Standard GS2/LK4 60 A J #10#3 Cu Standard LK4 100 A #14#2/0 Cu Standard GS2 100 A #142/0 Cu/Al 6 GS1AW303 59.00 GS2/LK4 200 A #63/0 Cu/Al 6 GS1AW403 98.00 GS2 400800 A 2 x 22 x 600 2 Cu/Al 6 GS1AW503 197.00 LK3 400600 A a LK3 8001200 A a 4 x 24 x 600 2 Cu/Al 12 GS1AW903 395.00 a GS1 600800 A and LK3 8001250 A can receive 1 lug for 3 cables per terminal or 2 lugs for 2 cables per terminal.
Terminal Lugs
Table 8.36:
For use on GS2JU3 GS2MU3 GS2QU3
GS2MU3 GS2QU3
Cu
GS1AW506
233.00
Table 8.37:
Terminal Shrouds
Catalog No. Standard Standard Standard Standard GS1AP33 GS1AP43 GS1APU53 LK3AP63 GS2AP73 LK3AP83 $ Price 101.00 132.00 140.00 86.00 140.00 101.00
Terminal Shrouds
For use on Line or Load Side a Compact GS1/LK3 All GS2/LK4 30 A All GS2/LK4 60 A LK4 100 A GS2 100 A b GS2/LK4 200 A b GS2 400 A LK3 400600 A GS2 600800 A LK3 8001200 A a All GS1 and LK3 switches supplied with line side shrouding. b Three piece kit for either line or load side.
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES Shorting Links
Table 8.38:
For use on GS2 60 A GS2 100 A GS2 200 A GS2 400 A GS2 600800 A
Shorting Links
Shorting Links per Kit 3 3 3 3 3 Catalog No. GS1AU203 GS1AU303 GS1AU403 GS1AU503 GS1AU803 $ Price 29.60 41.90 62.10 93.00 156.00
Table 8.39:
For use on Compact GS1/LK3 LK4 60200 A GS2 30400 A LK3 4001200 A GS2 600800 A
8-8
CP1
Discount Schedule
Dimensions
www.schneider-electric.us
3 3" 4
96.5
Door Drilling
2 4.5
19 32
"
1 15 " 32
37.3
"
2 1" 2
65
11 4 "
31
15
2"
50
-OFF
2.48"
63
90
9 4 16 "
1 25 " 32
-ON
45 25.6
116
3 1" 8
1"
79.5
1.72
43.9
1.57
40
1.10
28
FIX
ON TEST 2.75
3" 16
M5
70 90 65 0.27 (4) 7 1.22 31
18.3
FIX
3 1" 4
83.8
OFF
23 32
"
Door Drilling
2.0 50 90 -ON
-OFF
1.0 28
4.56
3.38 84
116
2.48 63
1.57 ON TEST
1.10
28
40
FIX
43.9
0.63
15.8
FIX 0.19
2.75
70
3.88 99
90
65
OFF
1.72
43.9 Door Drilling
1.57 5.88
149 Fix 5.25 133 40
ON 2.75
70 90 65
2.63
67
TEST
2.44 62
3.88
99
OFF
8-9
29
Dimensions
5.63
143
1.50
38
3.50
89
Door Drilling
5.88
149 67
1.57
40
1.10
28
ON TEST
90 65 70 0.27 (4) 7 1.22 31
2.63
2.75 OFF
2.75
70
6.75
171
2.06
52
5.63
143
3.44
87
Door Drilling
7.19
183
1.57
40
1.10
28
6.9
.25
ON 2.75
70 90 65
3.31
84
.75
19
3.31 8.25
210 84
OFF
6.00
152
Fix 2.44 62
3.44
87
Door Drilling
8.13
207
1.57 ON
TE
40
1.10
28
11 11.6
.44
ST
0.27 (4) 7
3.75
95 125.1
1.00
25
4.95
90
65
1.22 31
1.50
38
1.13
29
3.69
94
9.44
240
OFF
2.81
72
5.56 1.75
44.6 141
3.44
87
Door Drilling
14.31
363
1.57 ON
1.10
28
10 10.2
.38
TE
40
4.44
112 .25 6 125.1
ST
0.27 (4) 7
3.13
80
1.50
38
4.95
90
11.94
303
2.06
52
65
1.22 31
2.88
73
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
1.57
40
1.10 Door
28 Drilling
1.50
38
3.13 7.13
181 80
1.22 31
0.27 (4) 7
19.38
492
Locking 55
Terminal Lugs 2X600 MCM Max. 3X600 MCM Max. 44 .38 2.75 11 10 69 209.8
8.26
2.50
64
2.38
59
4.75 4.75
120 120
4.00
100
.50 190
13
7.50
1.56
40
20.38
517
2.40
61.1
2.88
73
3.00
76
8-10
Dimensions
www.schneider-electric.us
2.59
66
1.94
37
.59
15
1.00
25
.75
19
1.00
25
1.83
46
2 4.5
.13
Door Drilling
2.00
51 0-OFF 90
4.56
3.84
98
1.25
31
.56
14
.72
18
2.48
Fix .19 M5 63
-ON
3.88
99
.19 5
Fix 1.50 38
3.50
89
Door Drilling
1.57 5.88
149 Fix 5.25 133 40
1.10
28
ON 2.75
70 90 65
2.63
67
TEST
2.75
70
OFF
6.69
170
2.44
62
3.44
87 Door Drilling Terminal Lugs 3/0 Max.
8.13
206
1.57
40
1.10
28
11 11.6
.44
3.75
95 125.1
ON 4.95
TE
ST
1.50
38
1.00
25
1.13
29
3.69
94
90
65
9.50
241
OFF
6.56 1.56
40
3.13
80 Fix 12.63 320 Fix 6.88 175
166
1.63
41
Door Drilling
10 10.2 28
.38
5.00
127
1.57
40
1.10 3.13
80
1.50
38
2.31
59
209.8
8.26
1.22 31
0.27 (4) 7
.81
20
.56
14
2.88
73
11.00
279
2.40
61.1
Mounting Hole Dimension: 0.25 in. (6.3 mm) OPERATOR MECHANISMS AND DISCONNECT SWITCHES
1.57 1.56
40 40
1.10
28
4.75
121
13.00
330
2.31 .81 59
20
8.26
1.22 0.27 (4) 31 7 Terminal Lugs 2X600 MCM Max. 3X600 MCM Max. 44 .38 11 10
.81
20
1.56
40
2.50
64
14.63
372
3.13
80
1.50 3.56 38
91
1.56
40
2.40
61.1
2.88
73
3.00
76
8-11
The D10 disconnect switch features high I2T rating, longer contact life, visible contact indication, fuse-mounting flexibility, dead-front construction, and auxiliary interlocks. A complete installation includes a D10 disconnect switch, D11 handle operator, and D12 fuse clip kit. The D10 accepts Class H, K, J, or R fuses or can be used for non-fusible applications. The D10 disconnect switch is operated by a cast metal handle operator that is lockable in the OFF position and defeatable in the ON position. Table 8.40: Disconnect Switches (without fuse clips or shorting straps)
Max. Horsepower Ratinga Rating (A) 30 60 100 200 120 V 5 10 15 25 200 240 V 10 20 30 50 480 V 20 40 60 100 600 V 25 50 75 100 Catalog Number D10S1 D10S2 D10S3 D10S4 $ Price 270.00 292.00 452.00 860.00 a
Table 8.44:
Rating (A)
Lug Data
Number Per Pole Wire Range a #14#8 #14#4 #14#1/0 #6250 kcmil Wire Type Cu Cu AlCu AlCu
Table 8.45:
D10 Switch Size
600 VWith Service Entrance Rating Starter Max. Horsepower Rating a NEMA Rating 200 Type (A) 120 V 240 V 480 V 600 V Size 01 30 5 10 20 25 2 60 10 20 40 50 3 100 15 30 60 75 4 200 25 50 100 100 a Non-fused ratings Catalog Number D10S1H D10S2H D10S3H D10S4H $ Price 320.00 352.00 544.00 1154.00
Table 8.41:
Line Shield
Kits include: Handle, shaft, and actuator NEMA Type 1, 3, 3R, 4, and 12 Description Rating (A) Enclosure Interior DepthInches 56 610 1016 6 12 Catalog Number D11SF4 D11SF10 D11SF16 D11SH10 D11SH16 $ Price 106.00 118.00 130.00 26.20 32.80
B F A E
G H
Complete Kit with 30, Handle, Shaft, and 100, 60, 200 Actuator
Shaft only
Table 8.42:
(for mounting on 30 A200 A disconnect switch a) Block Description (with switch contacts open) 1 N.O. 1 N.C. 1 N.O. and 1 N.C. 2 N.O. 2 N.O. and 2 N.C. a One block per switch.
Table 8.43:
Interrupting Rating Withstandability I2T Amperes Symmetrical (Amperes2 seconds) 600 Vac, 3 30 1,200 0.38 x 106 60 1,800 1.28 x 106 100 2.000 2.62 x 106 200 3,600 5.25 x 106 Note: These switches are for motor circuit applications. Rating (A)
Fuse Clip Rating a Catalog $ Price Number Amperes AC Volts Type No Fuse D12C01 8.30 16.30 030 250 H, K D12C21 030 250 R D12CR21 65.00 24.50 030 600 H, K D12C61 030 600 R D12CR61 65.00 30 A 030 600 J D12CJ1 49.30 3160 250 H, K D12C22 24.50 3160 600 H, K D12C62 49.30 3160 600 R D12CR62 82.50 3160 600 J D12CJ2 57.50 61100 250 H, K D12C23 65.00 No Fuse D12D02 24.50 030 250 R D12DR21 65.00 030 600 H, K D12D61 24.50 030 600 R D12DR61 65.00 3160 250 H, K D12D22 23.80 3160 250 R D12DR22 82.50 60 A 3160 600 H, K D12D62 41.00 3160 600 R D12DR62 82.50 3160 600 J D12DJ2 57.50 61100 250 H, K D12D23 65.00 61100 600 H, K D12D63 115.00 61100 600 J D12DJ3 106.30 61100 600 R D12DR63 113.80 No Fuse D12E03 49.30 3160 250 H, K D12E22 41.00 3160 600 H, K D12E62 41.00 61100 250 H, K D12E23 32.50 61100 250 R D12ER23 115.00 100 A 61100 600 H, K D12F63 90.00 61100 600 R D12FR63 115.00 61100 600 J D12EJ3 115.00 101200 250 H, K D12F24 106.30 101200 600 H, K D12F64 122.50 101200 600 J D12FJ4 140.00 No Fuse D12F04 82.50 61100 600 H, K D12F63 90.00 101200 250 H, K D12F24 106.30 200 A 101200 250 R D12FR24 140.00 101200 600 H, K D12F64 122.50 101200 600 R D12FR64 135.00 101200 600 J D12FJ4 140.00 a Continuous current should not exceed switch rating (size). Fuse clip kits should be sized to accommodate inrush.
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
Table 8.46:
Rating (A) 30 60 100 200 a b A 7-5/16 7-5/16 9-27/32 12-3/16
Maximum depth with largest fuse. Depth including insulating barrier on service entrance switches.
8-12
CP1
Discount Schedule
Table 8.47:
Complete Kits
Use With Includes: Operating Mechanism Standard 6 in. Handle Standard Shaft Kit Mounting Type $ Price Depth a Min. Max. LG1 LN1 LP1 LJ1 LR1 LD1 LT1b LT1b LX1b LW1d 140.00 140.00 171.00 171.00 242.00 242.00 242.00 242.00 242.00 242.00 5-1/210-1/4 5-1/210-7/16 6-1/411-3/16 5-1/210-3/4 6-5/1610-7/8 7-1/412-1/16 7-3/1611-5/8 7-3/1611-5/8 8-1/412-3/4 7-3/1611-5/8 Includes: Operating Mechanism Standard 6 in. Handle Long Shaft Kit Mounting Type $ Price Depth a Min. Max. LG4 LN4 LP4 LJ4 LR4 LD4 LT4b LT4b LX4b LW4d 158.00 158.00 189.00 189.00 255.00 255.00 255.00 255.00 255.00 255.00 5-1/220-7/8 5-1/221 6-1/421-3/4 5-1/221-3/8 6-5/1621-1/2 7-1/422-5/8 7-3/1622-1/4 7-3/1622-1/4 8-1/423-3/8 7-3/1622-1/4 3 in. handles are not recommended for use with these circuit breakers. Includes: Operating Mechanism Short 3 in. Handle Long Shaft Kit Mounting Type $ Price Depth a Min. Max. LG3 LN3 LP3 LJ3 LJC 198.00 5-1/220-7/8 198.00 5-1/221 230.00 6-1/421-3/4 230.00 5-1/221-3/8 230.00 5-1/221-3/8
No. of Poles 3 23 23 23 23 23 23 23 23 3
Frame Size (A) 75, 100 100 250 250 400 400 800 1200 1200 1200
Operating
GJL FAL, FCL, FHL KAL, KCL, KHL NSF, PowerPact H and J LALc, LHLc, Q4L PowerPact D MEL, MXL MAL, MHL NAL, NCL, NEL, NXL PowerPact M and P e
Table 8.48:
Component Parts
Use With 3 in. Handle Standard Handle Assemblies Assemblies Type 1, 3R, 12 Type 1, 3R, 12 Frame Size (A) 75, 100 100 250 250 400 400 800 1200 1200 3 in. handles are not recommended for use with these circuit breakers. Type $ Price Type LH3 LH3 LH3 LH3 90.00 90.00 90.00 90.00 LH6 LH6 LH6 LH6 LH6 LH6 LH8 LH8 LH8 Operating Mechanism Includes Lockout Standard Shaft (Support Bracket Not Required) Long Shaft (Support Bracket Included)
Circuit Breaker or Interrupter Type GJL FAL, FCL, FHL KAL, KCL, KHL NSF, PowerPact H and J LALc, LHLc, Q4L PowerPact D MEL, MXL MAL, MHL NAL, NCL, NEL, NXL
No. of Poles 3 23 23 23 23 23 23 23 23
$ Price Type 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 LG7 LF1 LK1 LJ7 LL1 LD7 LM1 LM1 LX7
Mounting Mounting $ Price Depth a Type $ Price Depth a Min. Max. Min. Max. 68.00 5-1/210-7/16 LS8 21.50 5-1/221 71.00 5-1/210-7/16 105.00 6-1/411-3/16 105.00 5-1/210-1/4 170.00 6-5/1610-7/8 170.00 7-1/412-1/16 170.00 7-3/1611-5/8 170.00 7-3/1611-5/8 170.00 8-1/412-3/4 LS8 LS8 LS8 LS8 LS8 LS8 LS8 LS8 21.50 21.50 21.50 21.50 5-1/221 6-1/421-3/4 5-1/221-3/8 7-1/422-5/8
Type $ Price LS13 LS12 LS12 LS13 LS10 LS13 LS10 LS10 LS10 LS10 35.60 35.60 35.60 35.60 35.60 35.60 35.60 35.60 35.60 35.60
PowerPact M and Pe 3 1200 LHP8 50.00 LW7 170.00 7-3/1611-5/8 LS8 21.50 7-3/1622-1/4 a Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door in inches. b Types LT1, LT4, LX1, and LX4 include an 8 in. handle rather than a 6 in. handle. c Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. d Type LW1 and LW4 include an 8 in. handle (9421LHP8) rather than a 6 in. handle. e These circuit breakers must use the 9421LHP** or LCP** handles only.
Table 8.49:
3 in. Handle Assembly
Circuit Breaker or Interrupter Type GJL FAL, FCL, FHL KAL, KCL, KHL NSF, PowerPact H and J LAL, LHL, Q4L PowerPact D MEL, MXL MAL, MHL NAL, NCL, NEL, NXL
Table 8.50:
Circuit Breaker or Interrupter Type GJL a
Table 8.51:
CP1
Discount Schedule
8-13
Description Class Type $ Price Single Pole Double Throw 9999 R47 131.00 Double Pole Double Throw 9999 R48 221.00 a Optional accessory for use with 9421L operating mechanisms. Note: Not used with GJL, NAL, NCL, NEL, NXL, NSF, NSJ, PowerPact C, D, H, and J circuit breakers; use field-installed circuit breaker interlocks instead.
PowerPact M and P 3 1200 LHP48 90.00 LCP48 a Due to gasketing, NEMA Type 3 & 4 handle assemblies are NOT trip indicating.
149.00
Dimensions
3.50 Min.
45
1.18 30 .50
13
Refer to NEC Article 430-10 for minimum dimension from top mounting hole to wall or barrier X to insure adequate wire bending space.
1.38
35
4.72 1.77 45
120
3.94
100
.45
12 (2) #8-32 Tap
.28 Maximum
CLHandle Mechanism
7 Door Thickness
2.38
60 H Mounting Depth a L = Overall shaft length H = Distance from inside of enclosure door to circuit breaker mounting surface
Table 8.52:
Class
Min. Max. L = H2.50 5.50 10.25 9421 LG7, LG1, LG4, LG3 64 140 260 L = H2.88 5.50 10.44 9421 LF1, LN1, LN3, LN4 73 140 265 L = H3.63 6.25 11.19 9421 LK1, LP1, LP3, LP4 92 159 284 L= H3.00 5.5 10.75 9421 LJ1, LJ4, LJ7 76 138 273 L= H3.13 6.31 10.88 9421 LL1, LR1, LR4 79 160 276 L= H4.00 7.18 11.63 9421 LM1, LT1, LT4 102 182 295 L= H5.17 8.25 12.75 9421 LX7, LX1, LX4 131 210 324 L= H4.89 7.19 11.63 9421 LW1, LW4, LW7 124 183 295 Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door.
3.25 Minimum
83
(Both Sides)
4.50
114 Hinge Point of Door
2.25 1.50
38 57
.75
19
1.63 R
41
1.56
40
178 Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. C Handle L Mechanism
7.00
3.25 Minimum
83 Hinge Point of Door
(Both Sides)
4.50
114
2.25 1.50
38 57
.75
19
1.81
46
343 Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10.
13.50
5.13
130
C Handle & Ckt. Bkr. T oggle L
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
1.63 R
41
7.13
6.00
152
181
6.00
152
C30080-120
Panel drilling for FAL, FCL, FHL circuit breaker and operating mechanism
Panel drilling for KAL, KCL, KHL circuit breaker and operating mechanism
8-14
Dimensions
www.schneider-electric.us
2.00 2.00 51
51
1.00
25
C L Circuit Breaker
487 Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10.
19.19
8.00 Minimum 203 (Both Sides) Hinge 4.50 Point 114 of Door 1.66
42
9.00
229
2.00
51
3.00
76
1.50
38
X Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. (4) 5/16-18 Tap
4.57
116
1.59
40 (4) 1/4-20 Tap
4.937
125
1.63R
41
C L Circuit Breaker
3.09
79 (4) 1/4-20 Tap
.56
14
1.03
26 A
9.25
235 C Handle L
2.68
68
C L Handle
3.50
89
C Handle L
4.68
119
.38 .44
11 10
C L Handle
.38
10
8.00
203
6.00
152
.44
11
.88
22
1.63R
7.19
183
41
5.09 10.19
259 129
Panel Drilling for PowerPact H and J Circuit Breakers and Operating Mechanism
Panel Drilling for LAL, LHL, and Q4L Circuit Breakers and Operating Mechanism
Panel Drilling for MAL, MEL, MHL, and MXL Circuit Breakers and Operating Mechanism
Dimensions = in. (mm) A 10.69 (272) 11.47 (291) B 14.00 (356) 14.75 (375)
L 9.00 Minimum (Both Sides) Handle Mechanism 229 15.00 381 Hinge 3.16 7.50 Point 80 191 of Door 5.00 1.66 127 42 (4) 1/4-20 Tap 2.50 64
M
3.92 100
N
(4) 1/4-20 tap
12.13
308 241 C Handle L Mechanism
9.50 8.75
222
1.63R
41
8.00
203
R
2.51 64
1200 A: 4.10 104
C L Circuit Breaker
216
R
Panel Drilling for NAL, NCL, NEL, and NXL Circuit Breaker and Operating Mechanism
5.24 133 10.48 266 8.27 210 3.02 77
800 A: 2.49 63
8.50
Dim. = in. mm
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
Panel Drilling for PowerPact M and P Circuit Breaker and Operating Mechanism
8-15
Disconnect Switches
The 9422 disconnect switches are the ideal selecctons for PV Combiner Boxs internal disconnect switch and control panel applications. These switches are designed for variable depth, flange mounting, traditional side mounting and bracket mounting applications providing complete flexibility in the combiner box designes (see Tables 8.53 and 8.68). The switches are compatible with 9422A handle operators and 9423 door mechanisms and are UL recognized (E52360 Vol. 1 sec 18) and CSA certified. Table 8.53:
9422 TCN30
Vdc
208 240 480 600 (200) (230) (460) (575) 250 600 30 A 60 A 100 A 200 A 6.62518 6.62518 6.62518 7.5 25 7.5 15 30 60 15 30 60 125 20 50 75 150 5 10 20 40 15 30 50 50
770.00 ATEF101
9.1219.25a 40
ATF11 1389.00 ATF21 1503.00 ATF12 1530.00 ATF22 1646.00 ATF13d 2195.00 ATF23d 2307.00
11.38 400 A Fixed (A5 or A6 None TG1fg 2672.00 Depthb Handle) 75 125 250 350 50 50 For handle selection, see Table 8.55 400 A 15.8719 (A7 H, J, Variable or A8 400 400 TG2fg 3027.00 K, R Depthb Handle)e g Right hand flange mounting only and requires a special a 9422 R2 will extend maximum mounting depth 7 inches, see page 8-23 for enclosure. information. b Switches are fixed-depth or adjustable depending on handle selection. h Variable depth only no cable operator. c For ordering use the suffix 9422, i.e. TCN30 order using catalog number i See Table 8.59 for ordering information for the cable operator. 9422TCN30 NOTE: See page 18 and 19 for dimensional d Accommodates Class J fuses only. information. e Variable in increments of 0.63 inches. f Commercially available enclosures may not accept 9422TG1 and 2 operating mechanisms. Contact enclosure manufacturer for availability of enclosures of use with these switches.
The 9422 Bracket Mount Disconnect Switch is designed for combiner boxes and control panel applications. The Bracket Mount Disconnect Switch is shipped with the switch and external handle assembled to a bracket, ready for quick installation. A protective trim plate is provided to prevent any mounting screws from being accessible from the front. The trim plate also provides an attractive installation feature. The switches are fully compatible with the 9423 closing mechanisms. Table 8.54:
Disconnect Switch Size
30 A
7.5
7.5
15
20
60 A
15
15
30
50
10
30
H, J, K, R Ja None H, J, K, R Ja None H, J, K, R Ja
100 A
25
30
60
75
20
50
200 A
40
60
125
150
40
50
a Space saving designType J fuses mounted on the non-fused bracket. b For ordering use the suffix 9422, i.e. BTCN30 order using catalog number 9422BTCN30. Note: See page 8-16 for dimensional information.
Handle Information
1. 3 1
29
Table 8.55: 9422 Disconnect Switch and Circuit Breaker Handle Mechanisms 3.50 Maximum The Handle Mechanism kit contains all parts necessary for 89 On Enclosure Flange mounting the handle to the flange of the enclosure. Two flange mounting methods are offered. For right or left hand 6.13 (9422 A1 and A2) .88 156 22 4.50 (9422 A3 and A4) flange mounting use the Types A1 A4 and Types A9 A10 114 10.13 (9422 A9 and A10) kits. For right hand mounting only, use the Type A5 A8 handles. Stiffener 257
Bracket
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
C of Operating Mechanism L Door Interlock Hook Door Interlock Defeater Screw Door
5.69
OFF
RESET
144
1.06
27
Type A1
Cat. No.c $ Price Cat. No.c $ Price 4a A3 143.00 A4 257.00 6a A1 143.00 A2 257.00 6ad AP1 188.00 AP2 338.00 A9 158.00 A10 270.00 10b 12e A5 251.00 A6 320.00 12ef A7 300.00 A8 372.00 a Use with 30200 A 9422 switches and all circuit breaker mechanisms. b Use with Type D2 remote or dual adapter kit listed on page 8-24. c For ordering use the suffix 9422, i.e. A2 order using catalog number 9422A2. d Use only with 9422 RM1, 9422 CMP and PowerPact M and P operating mechanisms. e Use only with 400 A 9422TG1 and 9422TG2 disconnect switch. f Adjustable depth.
2.16
55
The type AP1 and AP2 handles are used exclusively on the PowerPact M and P Operating Mechanisms, 9422 RM1 and 9422 CMP. The dimensions are identical to 9422 A1.
2009 Schneider Electric All Rights Reserved
8-16
CP1
Discount Schedule
Disconnect Switches
www.schneider-electric.us
Accessories
333
Table 8.59:
Disconnect Switch Size 30 A 60 A
250 V 600 V TCF30 30 TCF33 60 30 TDF60 60 30 60 A TDF63 60 100 A TEF10 100 100 TF2 200 200 200 A TF3 200 200 400 A TG2 400 400 a Use Discount Schedule DE1 for price, not CP1.
333
Table 8.60:
Disconnect Switch Size 3060 A 100 A 200 A 400 A
Lug Data
Wire Size (Min-Max) Cu #14#2 #10#0 #6600 kcmil #4500 kcmil Al #10#2 #6#0 #6#600 kcmil Lug Kits Copper Cat No. CL0306F CL10F $ Price 69.00 159.00 Lug Kits Al Cat No. AL0306F AL10F $ Price 36.90 77.00
3335.25
Table 8.57:
Disconnect Switch Size
Electrical Interlocks
Switch Type TCF, TCN, TDF, TDN, TEF, TEN BTCF, BTCN, BTDF, BTDN, BTEF, BTEN Electrical Interlocks Cat No.c TC10a TC20b TC11a TC21b R8a R9b R35a R36b $ Price 120.00 239.00 120.00 239.00 83.00 243.00 275.00 521.00
Table 8.61:
Switch Type
30 A, 60 A, 100 A
30 A, 60 A
a b c
TF, ATF 200 A TF, ATF TG 400 A TG 1 N.C. or N.O. Contact depending on wiring. 2 N.C. or N.O. or 1 N.O. or 1 N.C. Contact depending on wiring. For ordering use the suffix 9999 i.e. TC10 order using catalog number 9999TC10.
100 A
1.41
4.00"
1.00 4.50
1.00
A
8.80"
B 0.30
Table 8.58:
Cable Length Cat. No. $ Price Cat. No. (inches) 36 9422CFT30 273.00 9422CFT31 TCN30C, TCF30C, 48 9422CFT40 291.00 TCF33C, TDN60C, TDF60C, TDF63C, 60 9422CFT50 291.00 9422CFT51 TEN10C, TEF10C 120 9422CFT10 333.00 9422CFT11 a Purchase handel mechanism separately (9422A1, A2, A3 or A4).
Switch Type
Table 8.62:
Dimensions
F in. (mm) E in. (mm) BTCN, BTDN, BTEN 6.56 (167) 8.00 (203) BTCF, BTDF, BTEF 9.50 (241) 1.88 (48) 8.56 (217) 10.00 (254) 11.88 (302) 6.38 (162) TFB1 11.50 (292) 3.88 (99) 9.50 (241) 12.00 (305) 13.19 (335) TFB2, TFB3 20.00 (508) 20.00b(508) a The minimum enclosure depth is greater than Dimension D since additional space is needed when mounting the mechanism. b Fuses and fuse base assembly do not extend beyond bracket. Note: Back panel support is recommended for Types TFB1, 2, & 3. Other devices may also require support if the flange is not sufficiently rigid. Type A in. (mm) C in. (mm) D in. (mm) Min. Enclosure Deptha in. (mm) Fusible Device
0.38
10
0.38
10
C Disconnect Device
ON
OFF
0.38
10
D Disconnect Device
Fused
(2) 0.38
CP1
Discount Schedule
8-17
A E
Disconnect Switches
Dimensions
Table 8.63:
Type TF1 TF2 TF2 TF2 TF3 a (A) 200 200 200 200 200
Switch Size
The dimensions shown may be extended 7 by utilizing 9422 R2 (two required per switch).
A T B C S K E S R B = Minimum to wall or barrier, right or left hand mounting to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. F
100 A For (4) 1/4-20 Tap H 200 A For (4) 5/16 -18 Tap B 200 A 100 A Enclosure Flange (2) 1/4-20 Tap Enclosure Door Dt Distance from outside of flange to disconnect switch mounting surface.
Q P
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
8-18
Disconnect Switches
www.schneider-electric.us
Table 8.64:
Handle MechanismType A5 through A8 NOTE: Commercially available enclosures may not accept type TG operating mechanisms. Contact the enclosure manufacturer for availability of enclosures for use with these switches.
3.75 Max.
95 "On"
1.44
37
B 11.28 286
X 16.06 408
B
3.00
76
Enclosure Flange
11.69 1.88
48 297
Note: B and X = Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430.10.
4.78
121
1.50 0.75
19 38
4.88
124
24.00
610
0.38
10
Operating Link
4.25
108
0.50
13
8.50
C of Operating L Handle 216
9.88
251
23.81
605
7.50
191
3.63
92
Figure 2
(2) Mtg. Holes in Switch Mtg. Surface D30064-973 B
Figure 1
Figure 3
Table 8.65:
5.50
140
1.86
47
Dimension D = Distance from outside of flange to disconnect switch mounting surface. For Type TG1 or TG2 with: Type A5 or A6 fixed depth handle mechanism Type A7 or A8 adjustable depth handle mechanism
13.54 1.40
36
12.14
308 B
344
0.86
22
0.60
D= D= 11.38 289 15.87 403 0.63 16
15
to
19 483
Weld
In steps of
C of Operating L Mechanism
23.80
604
25.00
635
24.00
610
* D = Mounting depth measured from the switch mounting surface to the surface of flange.
Weld
101
Class J Fuse 400 A 600 Volt Class H, K, R Fuses 400 A 250 Volt Class H, K, R Fuses 400 A 600 Volt Enclosure Provision for (2) 5/16 Mtg. Screws
8.13
206
Figure 4
Dim. = in. mm
Figure 5
8-19
Table 8.66: Bracket Mounted Operating Mechanisms for Use With Square D Circuit Breakers The circuit breaker operating mechanisms listed below are shipped with the external operating handle assembled to a bracket. Circuit breakers are not included and must be ordered separately. A trim plate is provided with each kit to prevent any mounting screws from being accessible from the front and also to provide an attractive installation.The operating handle is Type A1. These switches can be used with Class 9423 door closing mechanisms.
Operating Mechanism Use With Circuit Breaker or Interrupter Type No. of Poles Frame Size (A) Right Hand Flange Mounting Cat. No. $ Price
Table 8.67: Electrical Interlock KitsClass 9999 Optional accessory for use with circuit breaker operating mechanisms listed to the left and the flexible cable mechanisms listed below, except GJL.
Description Single Pole, Double Throw Double Pole, Double Throw Class 9999 9999 Type R26 R27 $ Price 131.00 243.00
FAL, FHL 23 100 BN1 257.00 KAL, KHL 23 250 BP1 270.00 LALa, LHLa, Q4L 23 400 BR1 543.00 a Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. Note: Some enclosures may not accept the listed bracket mounted operating mechanisms; contact the enclosure manufacturer.
Note: Not used with GJL; use field installed circuit breaker interlocks.
0.38
10
Table 8.68:
Type
Dimensions
A in. (mm) C in. (mm) D in. (mm) Min. Enclosure Deptha in. (mm) Fusible Device E in. (mm) F in. (mm)
0.38
10 Disconnect Device
ON
A E
OFF
D Disconnect Device
BG1, BN1 8.75 (222) 7.13 (181) 1.13 (29) 6.50 (165) 8.00 (203) BP1 9.13 (232) 7.38 (187) a The minimum enclosure depth is greater than Dimension D since additional space is needed when mounting the mechanism. b Fuses and fuse base assembly do not extend beyond bracket. Note: Back panel support is recommended for Types TFB1, 2, & 3. Other devices may also require support if the flange is not sufficiently rigid.
0.38
10
Fused
(2) 0.38
Table 8.69:
Class 9422Flexible Cable Mechanisms for Use With Square D Circuit Breakers
No. of Poles Frame Size (A)
For use with Square D circuit breakers and Class 9422 A handle operators. Especially designed for tall, deep enclosures where placement flexibility is required. See page 8-21 for dimensions.
Cable Mechanism Cable Mechanisms with A1 Handle For Types 1, 3, 3R, 4, 12 Catalog No. CGJ31 CGJ41 CGJ51 CGJ11 CFA31 CFA51 CFA11 CKA31 CKA51 CKA11 CLA31 CLA51 CLA11 $ Price 417.00 432.00 432.00 476.00 417.00 432.00 476.00 431.00 446.00 489.00 630.00 647.00 689.00
Cable Length Catalog No. $ Price 36 in. CGJ30 273.00 48 in. CGJ40 291.00 GJL 3 100 60 in. CGJ50 291.00 120 in. CGJ10 333.00 36 in. CFA30 273.00 FAL, FHL 2-3 100 60 in. CFA50 291.00 120 in. CFA10 333.00 36 in. CKA30 288.00 KAL, KHL 2-3 250 60 in. CKA50 305.00 120 in. CKA10 347.00 36 in. CLA30 486.00 LALa, LHLa, Q4L 2-3 400 60 in. CLA50 504.00 120 in. CLA10 548.00 a Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
8-20
CP1
Discount Schedule
X C
1.00
25
For use with Class 9422 A handle operators especially designed for tall, deep enclosures where placement flexibility is required.
Circuit Breaker Type MG-NSF PowerPact H- and J-Frame No. of Poles Frame Size A Cable Mechanism Length Type CSF30 CSF50 CSF70 CSF10 CSF304 CSF504 CSF104 CSJ30 CSJ50 CSJ10 CSJ304 CSJ504 CSJ104 CMP40 CMP50 CMP10 $ Price 288.00 305.00 323.00 347.00 297.00 314.00 356.00 486.00 504.00 548.00 500.00 516.00 558.00 759.00 785.00 857.00
1.44
37
4.25
108 Note: Bend radius in cable must never be less than 6 inches. Electrical clearances must be maintained between cable and live electrical parts.
36 in. 60 in. 2-3 250 84 in. 120 in. 36 in. MG-NSF 4 250 60 in. 120 in. 36 in. MG-NSJ 3 600 60 in. PowerPact D 120 in. 36 in. MG-NSJ 4 600 60 in. PowerPact D 120 in. 48 in. PowerPact 3 1200 50 in. M- and P-Framea 120 in. a Must use 9422AP1 or 9422AP2 Handle with this operating mechanism.
Table 8.71:
Type CGJ CFA CKA CLA CSF 3-Pole CSF 4-Pole CSJ 3-Pole CSJ 4-Pole CMP
Table 8.72:
Class 9999 Auxiliary Contact Kits for Disconnect Switches and Circuit Breakers
Type SPDT Type TC11 TC10 R8 R47 R26 R26 $ Price 120.00 120.00 87.00 131.00 131.00 131.00 Type TC21 TC11 R9 R48 R27 R27 DPDT $ Price 239.00 239.00 243.00 221.00 243.00 243.00
Class
Disconnect Switches 9422 BTCF, BTCN, BTDN, BTDF, BTEF, BTEN 9422 TCF, TCN, TDF, TDN, TEF, TEN 9422 TF Circuit Breaker Operating Mechanisms 9421 LF, LK, LL, LM, LN, LP LR, LT, LW , 9422 RM, RN, RP RQ, RR, RT , 9422 CFA, CKA, CLA, CSF, CMP
NOTE: No external auxiliary contacts are available for the following circuit breakers: GJL circuit breakers must use internal catalog No. AAC. PowerPact D circuit breakers must use internal catalog No. AAC. For additional variations, contact CIC at 1-888-SQUARE D (1-888-778-2733).
CP1
Discount Schedule
8-21
Features
Separate cables for each circuit breaker Rugged metal flange handle operator Maximized flexibility of circuit breaker placement for existing and new applications Control panel can be fed from two separate supply voltages (if required) Dual mechanism allows both separate supply voltages to be controlled by a single handle to improve security features Dual Cable Operating Mechanisms Selection
Cable Length in. / mm (quantity) 36 in. / 914 mm (2) 48 in. / 1219 mm (2) 60 in. / 1524 mm (2) 120 in. / 3048 mm (2) 36 in. / 914 mm (1) 60 in. / 1524 mm (1) 60 in. / 1524 mm (1) 120 in. / 3048 mm (1) 120 in. / 3048 mm (2) 36 in. / 914 mm (1) 60 in. / 1524 mm (1) 60 in. / 1524 mm (1-CSF 3 pole) 60 in. / 1524 mm (1-CSF 4 pole) 120 in. / 3048 mm (1-CSF) & 120 in. / 3048 mm (1-CSJ) 36 in. / 914 mm (1-CSF) & 36 in. / 914 mm (1-CSJ) 60 in. / 1524 mm (1-CSF) 60 in. / 1524 mm (1-CSJ) Catalog Number 9422CGJD3 9422CGJD4 9422CGJD5 9422CGJD1 9422CGJD8 9422CGJD9 9422CSFD1 9422CSFD35 9422CSFD345 9422CSFJD10 9422CSFJD30 9422CSFJD50 250 A & 600 A 250 A Frame Size (max.) $ Price 585.00 608.00 675.00 788.00 642.00 720.00 693.00 648.00 672.00 894.00 774.00 809.00
Table 8.73:
GJL
100 A
PowerPact D MG NSJ
Table 8.74:
FAL
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
8-22
CP1
Discount Schedule
Designed for installation in custom built control enclosures where main or branch circuit protective devices are required. All circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting, convertible on the job. Table 8.75: Variable Depth Mechanisms for Use with Square D and Schneider Electric (formerly Merlin Gerin) Circuit Breakers
Use with Circuit Breaker Frame Size Square D Circuit Breakers GJL FAL, FHL KAL, KHL LALc, LHLc, Q4L MEL, MXL MAL, MHL NAL, NCL, NEL, NXL 3 23 23 23 23 23 23 100 100 250 400 800 1200 1200 6.0017.75 5.3817.75 6.3817.88 7.4418.25 9.0018.38 9.0018.38 11.0018.37 RG1 RN1 RP1 RR1 RT1 RT1 RX1 116.00 116.00 129.00 329.00 449.00 449.00 513.00 ARG11 ARN11 ARP11 ARR11 ART11 ART11 257.00 257.00 270.00 471.00 593.00 593.00 ARG21 ARN21 ARP21 ARR21 ART21 ART21 372.00 372.00 386.00 585.00 705.00 705.00 No. of Poles Frame Size A Variable Depth Mtg. Range Min.-Max.a (Inches) Operating Mechanism OnlyDoes Not Include Handle Mechanism Type $ Price Operating Mechanism Operating Mechanism and Handle Mechanism Includes Type A1 Handle Mechanism Type $ Price Includes Type A2 Handle Mechanism Type $ Price
Schneider Electric (formerly Merlin Gerin) and PowerPact Frame 3-Pole Circuit Breakers MG-NSF PowerPact 23 250 5.8817.75 RQ1 185.00 H- and J-Frame MG-NSJ 3 600 9.0017.75 RS1 383.00 PowerPact D PowerPact 3 1200 10.5018.38 RM1 513.00 M- and P-Frame a Class 9422 Type R2 will extend mounting depth 7 inches (see page 8-24).
Table 8.76:
Description Class Single Pole, Double Throw 9999 Double Pole, Double Throw 9999 a Not for use with the GJL operating mechanism.
Table 8.77:
Circuit Breaker Frame Size
Dimensions
Type in. Width (A) mm in. Height (B) mm Distance to Enclosure Flangea (C) Minimum in. mm Maximum in. mm Bracket Depth (D) in. mm 102 108 125 152 246 246 229 143 146 222
GJL RG1 5.00 127 4.75 121 6.00 152 17.75 451 4.00 FAL, FHL RN1 6.75 171 8.50 216 5.51 140 17.75 451 4.26 KAL, KHL RP1 7.13 181 10.13 257 6.51 165 17.88 454 4.94 LALc, LHLc, Q4L RR1 10.19 259 11.00 279 7.44 189 18.25 464 6.00 MEL, MXL RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 MAL, MHLb RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 NAL, NCL, NEL, NXL RX1 19.63 499 13.50 343 11.00 279 18.37 467 9.00 MG-NSF RQ 4.84 123 7.97 203 5.875 149 17.75 451 5.62 MG-NSJ RS 9.27 236 9.5 241 9.0 228 17.75 451 5.73 PowerPact M & P RM 12.29 312 15 381 10.5 267 18.9 480 8.73 a 9422 R2 will extend dimension 7 in. Two required. b Minimum mounting depth when using MAL or MHL circuit breakers can be decreased to 7.63 inches by using the Class 9422 Type RT1B conversion kit. $23.00 c Warning: These operating mechanisms cannot be used with any LA / LH circuit breaker with an MB or MT suffix.
Enclosure Door
C = Distance from Outside of Flange to Circuit Breaker Mounting Surface Enclosure Flange D
C L.H. Handle L
C L R.H. Handle
Minimum to wall or barrier. Right or left hand mounting to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10.
CP1
Discount Schedule
8-23
Disconnect Switches
For the remote or dual operation of 30, 60, 100 and 200 A disconnect switches, or GJL, FAL, FHL, KAL, KHL, LAL, LHL, Q4L, MAL, MHL, MEL and MXL circuit breakers. Remote Operationpermits mounting the Class 9422 Type A9 or A10 handle mechanism at a lower level than the disconnect device it controls. This arrangement is often required where the disconnect device is mounted too high for personnel to easily reach a conventional operator. Dual Operationpermits controlling two disconnect devices, one in line with and one remote from a single Class 9422 Type A9 or A10 handle mechanism. NOTE: A Class 9422 Type A9 or A10 handle (page 8-17) and the preferred mounting method must be used. Table 8.78: Disconnect Device
Enclosure Mounting Depth Min. Disconnect Switch 30 A Type TCF/TCN 60 A Type TDF/TDN 100 A Type TEF/TEN 200 A Type TF Circuit Breaker GJL FAL, FHL KAL, KHL LAL, LHL, Q4L MAL, MHL,MEL, MXL 10.63 10.63 12.13 13.13 10.50 10.66 11.13 12.13 13.75 Max. 19.50 19.50 20.25 20.81 D2 19.50 19.50 19.50 19.88 20.25 251.00 Type $ Price
Disconnect Device
Table 8.79:
Note that air valve interlocks only accept the specific three-way air valves, manufactured by Parker, listed in the table below.
0.75 NPT G2 513.00 19 1.00 NPT M00080004 G1 513.00 25 Prices do not include air valves or handle mechanism. For more information on air valves listed above contact Parker at C-PARKER@PARKER.COM, or call 1-800-272-7537.
Table 8.80:
Accessory
Other Accessories
Description Permits mounting Class 9422 Type A1 or A2 handle mechanisms in enclosures with flange thickness of 16 gauge to 0.5 in. Auxiliary kit recommended for use with 30 and 60 A disconnect switches and FAL, FCL, FHL, KAL KHL, NSF and NSJ circuit breaker mechanisms when these devices are to be mounted on the center channel of a multi-door enclosure or when extra rigidity for the flange is required. Supplied as standard with 100 and 200 A disconnect switches and LAL, LHL, Q4L, MAL, MHL, MEL and MXL circuit breaker mechanisms. Auxiliary kit recommended for use with the Class 9422 Type A-1 flange handle to facilitate padlocking the handle in the OFF position. Primarily used when the handle is mounted on the center channel of a multi-door enclosure. Also in any case where the enclosure doors interfere with the normal padlock slot in the flange handle. Meets both the Automotive and NFPA 79 specifications. Copper Lugs onlySpecify Form Y157 Tin Plated Aluminum Lugs for 400 A Type TG SwitchSpecify Form Y1572 (000750 kcmil Cu/Al wire) Anderson Type VCEL Compression LugsSpecify Form Y1574 Exceptions: None of the 30 A or 60 A disconnect switches are available with compression lugs. Standard operating rod for use with Class 9422 variable depth mechanisms. Included as standard in each kit. Extra long operating rod for use with Class 9422 variable depth mechanisms. Can be used as a substitute for the standard rod included in each kit to increase the maximum mounting depth 7 in. (Two are required for Types ARR, RR, ART, RT, ATE, TE, ATF, TF). Class 9422 Type AM2 $ Price 14.30
9422
C1
42.80
9422
L1
36.00
9422 9422
R1 R2
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES Auxiliary Lock Plate
Operating Rods
8-24
CP1
Discount Schedule
Introduction
Class 9423 / Refer to Catalog 9420CT9701
Class 9423 door closing mechanisms cover a range of enclosures with up to 91 inch high maximum door openings. The door closing mechanisms are designed to be used on control enclosures and interlocked with a Class 9422 disconnect device, although they all can be used independently. Three different systems are available and their use is as recommended below. A complete system is available for interlocking all the doors of a multi-door enclosure with the master door when using the 6 in. or 8 in. vault handle mechanism. Note that the Master Door is defined to be the door of a single or multi-door enclosure which is interlocked directly with the disconnect device. The master door can be hinged on either the right or left hand side. It can be located in any position on a multi-door enclosure. On the other hand, an Auxiliary Door is defined to be any remaining doors of a multi-door enclosure which are interlocked with the master door by means of the overhead interlocking system as illustrated on pages 8-26 and 8-27.
Selection Procedure
9422 TCN30
Step 1. Determine enclosure construction (number of doors, door height, hinge location, etc.). Step 2. Determine Class 9422 disconnect device to be usedeither a disconnect switch or a circuit breaker mechanism. Step 3. Determine the location of the disconnect device and handle mechanism (right or left hand flange or center channel). Step 4. Select the door closing mechanism required. Step 5. Select the auxiliary door closing mechanisms and multi-door interlocking hardware, if required. (A complete system for interlocking all auxiliary doors of a multi-door enclosure with center channel is available for the medium and large enclosures.) Table 8.81: Door Closing Mechanism
4660 in. Door Opening (Recommended) 6191 in. Door Opening (Recommended)
2 Point Locking is Standard A Third Roller Latch Kit is Available for 3 Point Locking For 3/4 in. Door Depths
For use on Single or Multi-Door Enclosures For use with Doors Hinged on Right or Left Side Referred to as the 6 in. Vault Handle Mechanism For 3/4 in. Door Depths
For use on Single or Multi-Door Enclosures For use with Doors Hinged on Right or Left Side Referred to as the 8 in. Vault Handle Mechanism For 1-1/8 in. Door Depths
The door closing mechanisms listed below are for use on small to medium size single door control enclosures. They are designed to be used in conjunction with Class 9422 flange mounted disconnect switches and circuit breaker operating mechanisms; however, they can be used independently as well. When used on properly designed and gasketed NEMA Type 12 enclosures, they meet NFPA 79 standards. Table 8.82: Single Door EnclosuresNEMA Type 4 or 12 with 60 in. High Maximum Opening
Description For Use On (Enclosure Type) NEMA Type 4 and 12 Sheet Steel NEMA Type 4 and 12 Stainless Steel NEMA Type 4 and 12 Sheet Steel NEMA Type 4 and 12 Stainless Steel Use In Conjunction With Class 9422 Types A1, A3, A9 Class 9422 Types A2, A4, A10 Class 9422 Types A1, A3, A9 Door Latch Handle Length 4 in. 4 in. 6 in. 4 in. 4 in. 4 in. 6 in. 4 in. Suggested Maximum Door Opening Less than 39 in. Less than 39 in. 60 in. Less than 39 in. Less than 39 in. Less than 39 in. 60 in. Less than 39 in. a Door Depth Type M4 M10 M9 M24 M4L M10L M9L M24L M3 M23 $ Price 228.00 314.00 243.00 300.00 228.00 314.00 243.00 300.00 50.00 57.00
Two point, roller latch, door closing mechanism for use on enclosures with doors hinged on the left hand side. Two point, roller latch, door closing mechanism for use on enclosures with doors hinged on the right hand side.
Type M4 Latch bar not included, but most prepunched enclosures that accept Square D operating mechanisms supply a predrilled latch bar.
Class 9422 Types A2, A4, A10 Class 9423 NEMA Type 4 and 12 Third roller latch kit for 3 Types M4, M9, Sheet Steel point locking; for use where M4L, M9L 3 point locking is desired or Class 9423 where the door opening is NEMA Type 4 and 12 Types M24, 39 in. or more. Stainless Steel M24L a Suitable for door depths of 1-1/8 in., 1-1/4 in., 1-3/8 in. and 1-1/2 in..
CP1
Discount Schedule
8-25
Table 8.83:
NOTE: All mechanisms listed on this page are suitable for either left or right hand mounting. Table 8.84: Door Interlocks
$ Price
Locking Bar
Locking Bar
B
Door Opening
Type M6 Door Closing Mechanism The Class 9423 Type M6 door closing mechanism is designed to close and seal 0.75 in. deep doors of single or multi-door NEMA Type 12 enclosures. The Type M6 can be used on doors hinged on either the left or right hand side. Recommended door openings are from 4060 in. Vault type handle length is 6 in. Type M660 Locking Bar Kits The lock bar kit for the Type M6 door closing mechanism contains two lock bars and is available from stock. The bars can be cut to fit door openings through 60 in. One lock bar kit is required for each Type M6 ordered. Type M5 The Class 9423 Type M5 mechanical interlock kit is designed to interlock a Class 9422 handle mechanism with the Type M6 door closing mechanism. This kit prevents opening the master door (or single door) with the disconnect handle in the ON position, making it mandatory to use a screwdriver to gain entry to the enclosure at any time, regardless of the disconnect handle position.
257.00
86.00
215.00
Table 8.85:
C
Locking Bar Locking Bar
Type M2 One Type M2 kit is required for each auxiliary door. This kit is required to interlock any auxiliary door(s) with the master door. Type M7 The first auxiliary door requires 2 Type M7 kits. Additional auxiliary doors require only 1 Type M7 kit. The 0.25 in. diameter rod used to interconnect the M7 kits is furnished by the user. If the distance between any two Type M7 kits exceeds 36 in., an additional Type M7 kit should be installed to prevent the rod from buckling.
71.00
Auxiliary Door
Type M6
Type M5
Type M7
Type M2
Note: A - Interlocking lever extension of the flange mounted handle mechanism. Note: B - Actual enclosure openingnot door height. Note: C - Screwdriver interlock assembly can be ordered separately. Class 9423 Type CEQ2493. $45.00
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
8-26
CP1
Discount Schedule
1M8 door closing mechanism For each door: 1Type M891 locking bar kit 1M8 door closing mechanism 1Type M1 (for use with 9422A handles) 1Type M891 locking bar kit
For Master door: 1M8 door closing mechanism 1Type M891 locking bar kit 1Type M1 (for use with 9422A handles)
NOTE: All mechanisms listed on this page are suitable for either left or right hand mounting. Table 8.87: Door Interlocks
$ Price
Locking Bar
Locking Bar
B
Door Opening
Type M8 Door Closing Mechanism The Class 9423 Type M8 door closing mechanism is designed to close and seal 1.125 in. deep doors of single or multi-door NEMA Type 12 enclosures. The Type M8 can be used on doors hinged on either the left or right hand side. Recommended door openings are from 6191 in. Vault type handle length is 8 in. Type M891 Locking Bar Kits The lock bar kit for the Type M8 door closing mechanism contains two lock bars and is available from stock. The bars can be cut to fit door openings through 91 in.. One lock bar kit is required for each Type M8 ordered. Type M1 The Class 9423 Type M1 mechanical interlock kit is designed to interlock a Class 9422 handle mechanism with the Type M8 door closing mechanism. This kit prevents opening the master door (or single door) with the disconnect handle in the ON position, making it mandatory to use a screwdriver to gain entry to the enclosure at any time, regardless of the disconnect handle position.
500.00
86.00
428.00
Table 8.88:
C
Locking Bar Locking Bar
Type M2 One Type M2 kit is required for each auxiliary door. This kit is required to interlock any auxiliary door(s) with the master door. Type M7 The first auxiliary door requires 2 Type M7 kits. Additional auxiliary doors require only 1 Type M7 kit. The 0.25 in. diameter rod used to interconnect the M7 kits is furnished by the user. If the distance between any two Type M7 kits exceeds 36 in., an additional Type M7 kit should be installed to prevent the rod from buckling.
71.00
Auxiliary Door
Type M8
Type M1
Type M7
Type M2
CP1
Discount Schedule
8-27
Note: A - Interlocking lever extension of the flange mounted handle mechanism. Note: B - Actual enclosure openingnot door height. Note: C - Screwdriver interlock assembly can be ordered separately. Class 9423 Type CEQ2493. $45.00
0.25
6
1.50
38
2.25 Minimum
57 A
Enclosure Door Enclosure Door Opening Recommended 40 Inches Minimum 60 Inches Maximum
0.2 Dia.
5
17.69 Minimum
449
1.63 2.00
51 41
33.69 Minimum
856 71
2.81 3.69
94
1.00
25
Table 8.89:
2.63
67
Dimension B (Minimums)
Disconnect Device 60 A Disconnect Switch 100 A Disconnect Switch 200 A Disconnect Switch 400 A Disconnect Switch FAL, FHL, Circuit Breaker KAL, KHL Circuit Breaker ILL Circuit Breaker MAL, MHL, MEL, MXL Circuit Breaker If A = 1 Minimum B = 3-/16 5-1/4 11-5/8 15-1/16 4-27/32 11-5/32 17-31/32 18-5/8 If A = 4 Minimum B = 2-1/2 2-1/2 8-1/8 11-9/16 2-1/2 7-21/32 14-15/32 15-1/8 C 3-3/16 3-3/16 3-3/16 6-3/4 3-3/16 3-3/16 3-3/16 3-3/16
3.50
89 C L of Door
0.7 Dia.
18
0.88 Dia.
22
0.2
5
Dia. (2 Holes)
Reference
0.50
13
1.50
38
3.00 Minimum
76 A
Enclosure Door Enclosure Door Opening Recommended 61 Inches Minimum 91 Inches Maximum
0.2 Dia.
5
17.69 Minimum
449
1.88 2.50
64 48
33.69 Minimum
856
3.75
95
1.00
25
4.75
121
3.50
89 C L of Door +.010 -.000 1.00 Dia. 25
0.7 Dia.
18
2.25
57
Table 8.90:
0.2
5 Dia. (2 Holes)
Dimension B (Minimums)
Disconnect Device If A = 1 Minimum B = 2-15/16 4-3/4 11-1/8 14-9/16 4-11/32 10-21/32 17-15/32 18-1/8 If A = 4 Minimum B = 2-1/2 2-1/2 8-1/8 11-9/16 2-1/2 7-21/32 14-15/32 15-1/8 C 3-3/16 3-3/16 3-3/16 5-7/8 3-3/16 3-3/16 3-3/16 3-3/16
Type
TCF, TCN, TDF, TDN, TD 60 A Disconnect Switch TE, TEF, TEN TF TG RN1 100 A Disconnect Switch 200 A Disconnect Switch 400 A Disconnect Switch FAL, FHL Circuit Breaker KAL, KHL Circuit Breaker ILL Circuit Breaker MAL, MHL, MEL, MXL Circuit Breaker
8
OPERATOR MECHANISMS AND DISCONNECT SWITCHES
8-28
CP1
Discount Schedule
Table of Contents
Section 9
Panelboards
PANELBOARDS
NF
Pricing Procedures Merchandised Main Lug Panelboards Merchandised Main Circuit Breaker Panelboards Merchandised Main Lug & Main Circuit Breaker Merchandised Accessories QOB Branch Circuit Breakers Factory Assembled Panelboards and Circuit Breakers Factory Assembled Common Features Merchandised Main Lugs Panelboards Merchandised Main Circuit Breaker Panelboards Merchandised Main Lug & Main Circuit Breaker Panelboards with TVSS Merchandised Accessories EDB, EGB, EJB Branch Circuit Breakers Factory Assembled Panelboards Factory Assembled Common Features Merchandised Single Row (Column Width) Panelboards 14 inch Wide Panelboards
9-5 9-6 9-7 9-8 9-9 9-10 9-11 9-12 9-13 9-13 9-13 9-14 9-15 9-18 9-19 9-16 9-41
M New! NQ
9-1
Series Ratings
This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located in the same enclosure or a remote main located in a separate enclosure. Table 9.1: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Square D Brand Integral or Remote Main Circuit Breakers and Remote Main Fuses MG HD, JD HG, JG HJ, JJ HL, JL Square D Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges cde Type QO (B) QO (B) PL QO (B) PL QO (B) PL QO (B) PL QO (B) QO (B) GFI QO (B) AFI QO (B) AFI, QO (B) CAFI QO (B) VH QO (B) EPD QO (B) QO (B) AS QO (B) GFI QO (B) VH QO (B) PL QO (B) AFI QO (B) QO (B) GFI QO (B) AFI, QO (B) CAFI QO (B) EPD QO (B) VH QO (B) QO (B) GFI QO (B) AFI, QO (B) CAFI QO (B) EPD QO (B) VH QO (B) QO (B) GFI QO (B) AFI, QO (B) CAFI QO (B) EPD QO (B) VH 1 Pole 1530A 1530A 1570 A 1530 A 1520 A 1520 A 1530 A 1570 A 1530 A 1530 A 1530 A 1520 A 1570 A 1530 A 1520 A 1530 A 1570 A 1530 A 1520 A 1530 A 1570 A 1530 A 1520 A 1530 A 2 Pole 1560 A 15125 A 4060 A 150 A 1560 A 15125 A 1530 A 1560 A 150 A 1560 A 1570 A 1560 A 1560 A 15100 A 1560 A 1560 A 15100 A 1560 A 1560 A 3 Pole
NQ Panelboards
Class 1640
www.schneider-electric.us
Table 9.1:
9
PANELBOARDS
Max. Short Circuit Current Rating 22,000 42,000 65,000 100,000 125,000
LC400A
120/240 1PH
15150 A 1530 A 1530 A 1530 A 35150 A 1530 A 1570 A 15100 A 15100 A 240
65,000
QG
208Y/120
30,000
QG, HG, JG 65,000 HG, JG FC_ or KC_22___ FC_ or KC_32___ FC_ or KC_24___ FC_ or KC_34___ DJ 400A 100,000 EJ, FJ
208Y/120
30,000
208Y/120
30,000
208Y/120
18,000
LA/LH (L) 34200MC LA/LH (L) 34225MC LA/LH (L) 34250MC LA/LH (L) 34400MC
QD
HD, JD
LA, MA
QO (B) QO (B) AS QO (B) GFI QO (B) PL QO (B) AFI QO (B) QO (B) GFI QO (B) AFI QO (B) QO (B) AS QO (B) GFI QO (B) VH QO (B) PL QO (B) AFI QO (B) QO (B) GFI QO (B) AFI QO (B) QO (B) AS QO (B) GFI QO (B) AFI QO (B) QO (B) VH QO (B) GFI QO (B) AFI QO (B) H QOB2150VH Q2L-H QDL QO (B) QO (B) VH QOBVH QO (B) GFI QO (B) AFI QO (B) VH QOBVH QO (B) GFI QO (B) AFI QO (B) VH
1570 A 1530 A 1530 A 1530 A 1520 A 1570 A 1530 A 1520 A 1570 A 1530 A 1530 A 1530 A 1520 A 1570 A 1530 A 1520 A 1570 A 1530 A 1530 A 1520 A 1570 A 1530 A 1520 A 1570 A 1530 A 1530 A 1520 A 1530 A 1520 A 1530 A
15125 A 1530 A 1560 A 1530 A 15100 A 1530 A 15125 A 1530 A 1560 A 150 A 1560 A 15125 A 1560 A 15125 A 1530 A 1560 A 15125 A 1560 A 15100 A 150 A 100225 A 70225 A 15125 A 150 A 1560 A 15125 A 150 A 1560 A 1530 A
15100 A 1530 A 1530 A 1530 A 1530 A 35150 A 1530 A 15100 A 15100 A 1530 A 15100 A 35150 A 100225 A 70225 A 15100 A 15100 A 1530 A
200,000
FI, KI 400 A Max. Class J or T6 Fuses 200 A Max. Class T3 Fuses 200 A Max. Class J or T6 Fuses and 400 A Max. Class T3 Fuses
65,000 100,000
200,000
a b c d e f
For shown circuit breakers rated less than this maximum voltage, the indicated short circuit current rating also applies, but at the voltage rating of the circuit breaker. Short circuit tests are conducted at 100105% of the maximum rated voltage of the panelboard. Suffixes HID, SWD, and SWN may also be applied to the applicable branch circuit breakers shown above. Suffix SWN may not be applied in combination with LC main breakers. Where QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QH (B) circuit breakers may also be used. Where QO (B) GFI circuit breakers are shown above, QO (B) EPD circuit breakers may also be used. To acheive selective coordiantion, the rating of the DJ main circuit breaker must be at least two times greater than the ampere rating of any branch circuit breaker.
9-2
Series Ratings
www.schneider-electric.us
This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located in the same enclosure or a remote main located in a separate enclosure
Table 9.2: NF Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Max. Maximum Short System Circuit Voltage, Current AC a Rating Square D Brand Integral or Remote Main Circuit Breakers and Remote Main Fuses Square D Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges
(continued)
Max. Short Maximum Circuit System Current Voltage, Rating AC a (RMS Symm.) Square D Branch Circuit Breakers Integral or Remote 2- or 3-pole Main Circuit Breaker Designation Poles
EDB, EDB-EPD 65,000 EG, FH, FG, KH, LH, MH, MX, HG, JG, DG EG ECB-G3 EJ, FC, FJ, KC, LC, LX, HJ, JJ EDB, EDB-EPD, EGB 100,000 EJ, FC, KC, HJ, JJ ECB-G3 120 DJ EDG. EGB 120/240 240 125,000 HL, JL EDB, EDB-EPD, EGB, ECB-G3 FI, KI, LI, LXI EDB, EDB-EPD, EGB, EJB 200,000 FI, KI ECB-G3 Class J or T (600 V) 200 A Max Fuses ECB-G3 EG, FG, KH, LH, HG, JG, DG EDB, EDB-EPD 35,000 EG, HG, JG ECB-G3 EJ, FC, FJ, KC, LC, LX, HJ, JJ, DJ EDB, EDB-EPD, EGB 65,000 EJ, FC, KC, HJ, JJ ECB-G3 HL, JL EDB, EDB-EPD, EGB, EJB 277 480Y/277 100,000 DL EDG, EGB, EJB 400 A Max Fuses EDB, EDB-EPD, EGB, EJB FI, KI, LI, LXI EDB, EDB-EPD, EGB, EJB 200,000 FI, KI ECB-G3 200 A Max Fuses EDB, EDB-EPD, EGB, EJB, ECB-G3 18,000 HG, JG, MG EDB EDB, EGB 25,000 EJ, FI, KH, KI, LC, LE, LX, LI, LXI, HJ, JJ LH (1570 A), EDB, EGB LC, LE, LX EDB, EGB, EJB 600Y/347 35,000 50,000 HL, JL EDB, EGB, EJB FI, KI EDB, EGB, EJB 65,000 LI, LXI EJB 200,000 Class J or T (600 V) 200 A max Fuses EDB, EGB, EJB a
.
240
200k
25k 35k
277
1 2, 3 2, 3
Short circuit tests are conducted at 100105% of the maximum rated voltage of the panelboard.
2, 3
Table 9.3: I-Line Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Max. Short Maximum Circuit System Current Voltage, Rating AC a (RMS Symm.) 42k 65k 120 100k 208Y/120 100k 35k 240 42k 50k Square D Branch Circuit Breakers Integral or Remote 2- or 3-pole Main Circuit Breaker MG QG, LH FJa, QJ QJ, LC QJ QJ, PH, PJ, RJ MG KA LA, MA MG MG HG, JG JG QG LH, MH, PA, PG, RG FGa, FH, MH, MX, PJ FC, KC, KH, LC, LH LH LH MG DG RL FC, KC, LC, LX PH, PJ, RJ QJ FJa FC, KC LC, LX KC, LC, LX KC, LC LC LC HJ, JJ JJ LC, LX, MJ, PJ, RJ MJ DJ RL HL, JL JL PC, PH, PL, RL PC, PL, RL Designation FY FA, FDa FDa FA FA, FDa QD, QG FA FDa HD, JD, QD FA FA (25 A Max.) FA, HD JD, QD FA, FDa, QD HD, JD, QD FDa FDa, FGa FA LA HD, JD, KA FH, HD, JD, KA, LA, MA FH, KH FDa, FGa, FJ QD, QG FDa FDa FA, FH, FDa, FGa, FJa FH, FDa, FGa, FJa KA KH LA, LH, MG FA FA, FH, HD, HG JD, JG HD, HG, JD, JG LA, LH FH, HD, HG, JD, JG, KA, LA, MA, MG RG HD, HG, HJ, FA, FH JD, JG, JJ HD, HG, JD, JG HH, JJ Poles
42k 50k
2, 3 2, 3
480 65k
2, 3
2, 3
200k
2, 3 2, 3 2, 3 2, 3 2, 3
240
65k
85k
2, 3
2, 3 2, 3 2, 3
2, 3
35k 50k
240
100k
1, 2, 3
2, 3
2, 3
600Y/347 2, 3 a
240
125k
Obsolescent. Contact the Square D/Schneider Electric local Field Sales Office for the replacement circuit breaker.
9-3
65k
FI, KI, LI, LXI HD, HG, HJ KI, LI, LXI JD, JG, JJ FI, KI, LI, LXI FDa, FGa, FJ FI,KI FA, FH, FC, FDa, FGa, FJa LI, LXI FH, FDa, FGa, FJa LI FC KI, LI, LXI KA, QD, QG, QJ LI KC FH, KA FDa FGa, KH, LH FDa DG FH, FY FJa FDa FC, KC FA, FH, FY, FDa, FGa LC, LX (400 A Max.) FH LC, LX (600 A Max.) FY, FDa, FGa DJ FH, FY DL FH, FJ FI, KI FA, FH, FY, FDa, FGa, FJ LI, LXI (400 A Max.) FH LI, LXI (600 A Max.) FY, FDa, FGa, FJ MG FA KH, LA, MA, MX, PA, PC, FH LA, MA, PA, PC, PX KA LA, MA, PA HD, JD FA (25 A Max.), MG MH, MX, PA HD, JD HG, JG FA, HD JG JD LH, MG, PG, RG HD, JD LH HG, JG DG FH, HD, JD, KA, LA, MA MJ FH (25 A Max.) RL RG MJ KA, KH FC, KC FA, FH HJ, JJ FA, FH, HD, HG JJ JD, JG LC, LI, LX, LXI HD, HG, JD, JG LC, LX (400 A Max.) FH KC, LC, LX KA LC, LX LA DJ FH, HD, HG, JD, JG, KA, LA, MA HL, JL FA, FH, HD, HG, HJ JL JD, JG, JJ LI, LXI (600 A Max.) KA DL FH, HD, HG, HJ, JD, JG, JJ, KA, LA, MA PC, PH, PL, RL HJ, JJ RL RG FI, KI FA, FH, FC, HD, HG, HJ KI JD, JG, JJ, KA LI FC, KA, KC, LA, HJ, HL, JJ, JL LXI KA, HJ, HL, JJ, JL FH, KA FDa FGa, KH, LH FDa FJa FDa FC, KC FDa, FGa LC, LX (600 A Max.) FDa, FGa FI, KI FDa, FGa, FJa LI, LXI (600 A Max.) FDa, FGa, FJa HG, JG FA, HD JG JD MG, PG, RG HD, JD MG FA HJ, JJ FA, HD, HG JJ JD PJ, RJ MG FH, HD, HG, HJ, LC HL, JL FA, HD, HG, HJ JL JD, JG, JJ PK HJ, JJ, MJ FI, KI HD, HG, HJ KI JD, JG, JJ KI, LI FH LI LA MG FA (25 A max.) MJ FA (30 A max.) HL, JL FJ
2, 3 1
2, 3
1 1
PANELBOARDS
Series Ratings
I-Line Panelboards
Class 2110
www.schneider-electric.us
Table 9.4:
9
PANELBOARDS
120/240 1 208Y/120
240
65,000
240
240
200,000
480
100,000
480
200,000
600 A
600
100,000
600
200,000
Note: The fuse used in this UL test is an envelope (umbrella) fuse. This fuse is designed as a worst case fuse. Thus, no matter what manufacturers fuse is used, the Square D circuit breaker is protected. The line side fused switch may be in a separate enclosure, or in the same enclosure as the loadside circuit breaker. A line side fused switch may be a submain, integral main, or remote main. A load side circuit breaker may be a branch, submain, or an integral main used on the load side of a remote main. This series combination short circuit current rating shall not exceed that of the line side fused switch. The charts apply to Square D Company load side circuit breakers only. However, the line side fuse ratings are independent of the fuse manufacturer. Not applicable to Corner Grounded Systems. Limiters used in Square D DSL and DSL II fused power circuit breakers are not class L fuses and do not have series ratings.
9-4
1. 2.
Select BASE PRICE for main lugs or main circuit breaker from BASE PRICE TABLE. Include equipment ground bar when required. List BRANCH CIRCUIT BREAKERS (either plug-on or bolt-on) and determine total spaces required. Select price from BRANCH CIRCUIT BREAKERS TABLE. Include space only charge for future requirements. If total spaces required exceeds the maximum listed, price as two or more panelboards and add price for sub-feed or feed-through lugs, so installer can cable between sections. Add price for special features from appropriate page. Contact field office for additional special features.
4.
3.
4. 5.
5. 6.
NOTE: Additional special price adders can be found in the Supplemental and Obsolescence Digest, Section 4.
6. Apply appropriate discount schedule.
NQ Merchandised Example
Table 9.5: 208Y/120 Vac, 34W, 10 kA SCCR, 225 A, MLO, Type-1 surface mount, bolt-on branch circuit breakers, main sub-feed lugs
Page No. 9-10 9-10 9-10 Catalog Number (20) QOB120 two QOB240 two QOB330 Spaces 20 4 6 Total 30 Total Price : $ Price 795. 177. 585.
Item 225 A MLO Base Price (20) 20/1 Bolt-on two 40/2 Bolt-on two 30/3 Bolt-on Sub-feed Lugs
NF Merchandised Example
Table 9.6: 480Y/277 Vac, 34W, 25 kA SCCR, fully rated, copper bus, 100 A, main circuit breaker, Type 1 flush mount, bolt-on branch circuit breakers
Page No. 9-15 9-15 9-15 Catalog No. EGB14020 EGB24040 EGB34050 Spaces 13 2 3 Total 18 Total Price: $ Price 3315. 776. 1131.
Item 250 A Main Circuit Breaker Base Price Copper bus adder (13) 20/1 one 40/2 one 50/3
Main circuit breaker adapter kit (less circuit breaker) Main circuit breaker 125 A MLO Cu Bus Int. Box Cover
Discount Schedule
9-5
NQ Merchandised Panelboards
Table 9.9:
9
PANELBOARDS
Pole Spaces
Mains Rating
Height (In.)
Type 1
20 in. Wide Cabinet gSingle Phase 3-Wire 18 100 30 30 42 225 72d 84d 30 42 84d 30 42 84d 600 400 1395. 1474. 1585. 1675. 1744. 1819. 2002. 2080. 3073. 3206. 3521 3677. 2462. 2579. 2620. 2738. 4853. 2705. 2861. 5099. 2977. 3056. 3149. 3239. 3308. 3383. 3556. 3634. 4900. 5033. 5288. 5444. 4229. 4346. 4387. 4505. 6534. 4548. 4704. 6873. NQ18L1 NQ18L1C NQ30L1 NQ30L1C NQ30L2 NQ30L2C NQ42L2 NQ42L2C NQ72L2 NQ72L2C NQ84L2 NQ84L2C NQ30L4 NQ30L4C NQ42L4 NQ42L4C NQ84L4C NQ30L6C NQ42L6C NQ84L6C 785. 864. 945. 1035. 1104. 1179. 1340. 1418. 2297. 2430. 2679. 2835. 1620. 1737. 1778. 1896. 3792. 1863. 2019. 4038. MH68 MH50 MH68 113. NC68V ( ) NC50V ( ) NC68V ( ) 948. 729. 948. NC68V( )HR NC50V( )HR NC68V( )HR 1185. 912. 1185. MH68WP MH62WPe MH80WPe 2742. 2685. 2835. 68 50/62 68/80 MH50 113. NC50V ( ) 729. NC50V( )HR 912. MH50WP 2609. 50 MH26 113. MH32 MH32 MH38 113. MH44 MH50 NC44 ( ) NC50 ( ) 663. 729. NC44( )HR NC50( )HR 830. 912. MH44WP MH50WP 2603. 2609. 44 50 NC32 ( ) NC32 ( ) NC38 ( ) 527. 527. 549. NC32( )HR NC32( )HR NC38( )HR 657. 657. 687. MH32WP MH32WP MH38WP 2204. 2204. 2216. 32 32 38 NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26
20 in. Wide Cabinet g Three Phase 4-Wire 18 100 30 30 42 54 72d 84d 30 42 72d 84d 30 42 84d a b c d e f g 600 225 1486. 1561. 1752. 1831. 1855. 1932. 2138. 2213. 2559. 2655. 3307. 3436. 3794. 3944. 2704. 2822. 2854. 400 2975. 4449. 4657. 5327. 2983. 3116. 5609. 3068. 3143. 3316. 3395. 3419. 3496. 3692. 3767. 4113. 4209. 5134. 5263. 5561. 5711. 4471. 4589. 4621. 4742. 6134. 6342. 7008. 4826. 4959. 7383. NQ418L1 NQ418L1C NQ430L1 NQ430L1C NQ430L2 NQ430L2C NQ442L2 NQ442L2C NQ454L2 NQ454L2C NQ472L2 NQ472L2C NQ484L2 NQ484L2C NQ430L4 NQ430L4C NQ442L4 NQ442L4C NQ472L4 NQ472L4C NQ484L4C NQ430L6C NQ442L6C NQ484L6C 876. 951. 1112. 1191. 1215. 1292. 1476. 1551. 1898. 1994. 2531. 2660. 2952. 3102. 1862. 1980. 2012. 2133. 3449. 3657. 4266. 2141. 2274. 4548. MH62 MH68 MH50 MH68 113. MH50 113. NC62V ( ) NC68V ( ) NC50V ( ) NC68V ( ) 887. 948. 729. 948. NC62V( )HR NC68V( )HR NC50V( )HR NC68V( )HR 1109. 1185 912. 1185. MH62WP MH68WP MH62WPe MH80WPe 2685. 2742. 2685. 2835. 62 68 50/62 68/80 NC50V ( ) 729. NC50V( )HR 912. MH50WP 2609. 50 MH44 MH50 MH38 113. NC44 ( ) NC50 ( ) 663. 729. NC44( )HR NC50( )HR 830. 912. MH44WP MH50WP 2603. 2609. 44 50 NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38 MH26 113. MH32 MH32 NC32 ( ) NC32 ( ) 527. 527. NC32( )HR NC32( )HR 657. 657. MH32WP MH32WP 2204. 2204. 32 32 NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26
C suffix indicates copper bussing. Embossed mounting holes add a .25 inch standoff to back of MH box. Add F for flush, S for surface. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. When NEMA 3R, 5, or 12 enclosures are selected, an NQ12RDE kit should also be selected. See Table 9.17. Enclosure includes trim kit. For 14 in. wide offer, see the Supplemental & Obsolescence Digest.
9-6
PE1A
Discount Schedule
NQ Merchandised Panelboards
www.schneider-electric.us
Table 9.10:
Main Circuit Breaker InteriorsWill accept plug-on and bolt-on circuit breakers
Type 3R, 5, 12 Enclosure e Enclosure 20 in. W x 6.5in. D Height (In.) Catalog $ Price No.
20 in. Wide Cabinet hSingle Phase 3-Wire 16k 28k 18 30 30 42 72d 84d 30 42 84d 1395. 100 1474. backfed 1585. 1675. 100 100 225 225 225 225 400 400 400 2227. 2306. 2501. 2591. 2660. 2735. 2962. 3040. 3976. 4109. 4459. 4615. 3400. 3517. 3558. 3676. 5686. 2977. 3056. 3149. 3239. 3781. 3860. 4328. 4418. 4487. 4562. 4729. 4807. 5729. 5862. 6144. 6300. 5085. 5202. 5243. 5361. 7407. NQ18L1 NQ18L1C NQ30L1 NQ30L1C NQ18L1 NQ18L1C NQ30L1 NQ30L1C NQ30L2 NQ30L2C NQ42L2 NQ42L2C NQ72L2 NQ72L2C NQ84L2 NQ84L2C NQ30L4 NQ30L4C NQ42L4 NQ42L4C NQ84L4C 785. 864. 945. 1035. 785. 864. 945. 1035. 1104. 1179. 1340. NQMB2HJ 1418. NQMB2Q 2297. 2430. NQMB2KI 2679. 2835. 1620. 1737. 1778. 1896. NQMB4LA NQMB4LA NQMB2HJ NQMB2HJ 780. HD, HG, HJ, HLl 100A maximum 780. 780. HD, HG, HJ, HLl 780. or JD, JG, JJ, JL QB,QD,QG,QJ 780. 780. 780. 780. 780. LA/LHm LA/LHm LA/LHm KI MH62 MH62 MH62 MH80 MH38 MH44 MH44 MH50 MH56 Select QOB 2-pole or QOB-VHi MH26 MH32 113. 113. 113. 113. 113. 113. 113. 113. NC26 ( ) NC32 ( ) NC38 ( ) NC44 ( ) NC44 ( ) NC50 ( ) NC56 ( ) NC62 ( ) 497. NC26( )HR 527. NC32( )HR 549. NC38( )HR 663. NC44( )HR 663. NC44( )HR 729. NC50( )HR 786. NC56( )HR 887. NC62( )HR 887. NC62V( )HR 887. NC62V( )HR 1001. NC80V( )HR 620. MH26WP 657. MH32WP 687. MH38WP 830. MH44WP 830. MH44WP 912. MH50WP 983. MH56WP 1109. MH62WP 1109. MH62WP 1109. MH62WP 1245. MH80WP 2192. 2204. 2216. 2603. 2603. 2609. 2652. 2685. 2685. 2685. 2835. 26 32 38 44 44 50 56 62 62 62 80
3792. NQMB4LA
20 in. Wide Cabinet hThree Phase 4-Wire 15k 27k 18 100 30 30 42 54 72d 84d 30 42 72d 84d a b c d e f g h i j k l m 225 1395. 100 1474. backfed 1585. 1675. 2318. 2393. 2668. 2747. 2771. 2848. 3098. 3173. 3519. 3615. 4210. 4339. 4732. 4882. 3642. 3760. 3792. 400 3913. 5314. 5522. 6160. 2977. 3056. 3149. 3239. 3872. 3947. 4495. 4574. 4598. 4675. 4865. 4940. 5286. 5382. 5963. 6092. 6417. 6567. 5327. 5445. 5477. 5598. 6986. 7194. 7881. NQ418L1 NQ418L1C NQ430L1 NQ430L1C NQ418L1 NQ418L1C NQ430L1 NQ430L1C NQ430L2 NQ430L2C NQ442L2 NQ442L2C NQ454L2 NQ454L2C NQ472L2 NQ472L2C NQ484L2 NQ484L2C NQ430L4 NQ430L4C NQ442L4 NQ442L4C NQ472L4 NQ472L4C NQ484L4C 785. 864. 945. 1035. 876. 951. 1112. 1191. 1215. 1292. 1476. 1551. NQMB2HJ 1898. NQMB2Q 1994. NQMB2KI 2531. 2660. 2952. 3102. 1862. 1980. 2012. 2133. 3449. 3657. NQMB4LA 780. 780. LA/LHm LA/LHm MH74 MH80 113. NC74V ( ) 113. NC80V ( ) 972. NC74V( )HR 1001. NC80V( )HR 1215. MH74WP 1245. MH80WP 2757. 2835. 74 80 MH62 NQMB4LA 780. LA/LHm 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62 780. HD, HG, HJ, HL or JD, JG, JJ, JL QB,QD,QG,QJ 780. 780. KI MH56 MH62 113. 113. NC56 ( ) NC62 ( ) 786. NC56( )HR 887. NC62( )HR 983. MH56WP 1109. MH62WP 2652. 2685. 56 62 MH50 113. NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50 780. MH44 NQMB2HJ 780. HD, HG, HJ, HL 100A maximum MH38 MH44 Select QOB 3-pole or QOB-VHj MH26 MH32 113. 113. 113. 113. 113. NC26 ( ) NC32 ( ) NC38 ( ) NC44 ( ) NC44 ( ) 497. NC26( )HR 527. NC32( )HR 549. NC38( )HR 663. NC44( )HR 663. NC44( )HR 620. MH26WP 657. MH32WP 687. MH38WP 830. MH44WP 830. MH44WP 2192. 2204. 2216. 2603. 2603. 26 32 38 44 44
4266. NQMB4LA
C suffix indicates copper bussing. Embossed mounting holes add a .25 inch standoff to back of MH box. Add F for flush, S for surface. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. Enclosure includes trim kit. Select the appropriate main circuit breaker from tables starting on page 7-22 and add the circuit breaker price to the total price of the panelboard. Circuit breaker interrupt ratings, see tables starting on page 7-22. For 14 in. wide offer, see the Supplemental & Obsolescence Digest. QOB2150VH takes four pole spaces; all other QOB two pole circuit breakers take two pole spaces. QOB3110VH to QOB3150VH take six pole spaces; all other QOB three pole circuit breakers take three pole spaces. Pole spaces shown are available for branch circuits, with spaces deducted for the back fed main breaker. For single phase applications, order a 3-pole breaker. Example: HDL36100. For 400A applications order short handle circuit breaker (LAL36400MB).
PE1A
Discount Schedule
9-7
PANELBOARDS
Total $ Price Type 1 Enclosure Interior Only Interior, Front, (Order Branch Circuit Main Circuit Breaker Adapter Kit Box and (Less Circuit Breaker) f Box Pole Mains Adapter Kit f Breakers Separately) Mono-Flat Front Hinged Front 20 in. W x 5.75 in. D b Spaces Rating Type 1 Type 3R, Catalog No. a $ Price Catalog No. $ Price Circuit Breaker Catalog No. $ Price Catalog $ Price Catalog No. $ Price 5, 12 Frame Size g No. c
NQ Merchandised Panelboards
Table 9.11:
NQ Main Lug and Main Circuit Breaker Interiors with TVSS240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0701
www.schneider-electric.us
9
PANELBOARDS
Voltage
Surge Rating
Type 1 120,000 A 225 A 30 208Y/120 Vac 160,000 A 120,000 A 225 A 42 208Y/120 Vac 160,000 A 225 A 72d 208Y/120 Vac 120,000 A 120,000 A 400 A 42 208Y/120 Vac 160,000 A 400 A a b c d e 72d 208Y/120 Vac 120,000 A 24026. 24103. 28141. 28218. 24344. 24419. 28459. 28534. 25500. 25629. 25042. 25163. 29156. 29278. 26532. 26740.
Type 3R, 5, 12 Catalog Number a 25793. 25870. 29908. 29984. 26097. 26172. 30212. 30287. 27185. 27314. 26723. 26844. 30837. 30959. 28253. 28461. NQ430L2TVS212 NQ430L2TVS212C NQ430L2TVS216 NQ430L2TVS216C NQ442L2TVS212 NQ442L2TVS212C NQ442L2TVS216 NQ442L2TVS216C NQ472L2TVS212 NQ472L2TVS212C NQ442L4TVS212 NQ442L4TVS212C NQ442L4TVS216 NQ442L4TVS216C NQ472L4TVS212 NQ472L4TVS212C
$ Price 23184. 23261. 27299. 27375. 23445. 23520. 27560. 27635. 24500. 24629. 23981. 24102. 28095. 28217. 25418. 25626.
MH50
113.
NC50( )
912.
MH50WP
2609.
MH56
113.
NC56( )
983.
MH56WP
2652.
MH62
113.
NC62( )
1109.
MH62WP
2685.
MH68
113.
NC68V( )
1185.
MH68WP
2742.
MH80
113.
NC80V( )
1245.
MH80WP
2835.
C suffix indicates copper bussing. Embossed mounting holes add a .25 inch standoff to back of MH box. Add F for flush, S for surface. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. Enclosure includes trim kit.
Table 9.12:
Surge Rating
225 A
30
26726. NQ430L2TVS212C 23261. 30840. NQ430L2TVS216C 27375. NQMB2HJ or 26967. NQ442L2TVS212 23445. NQMB2Q 27042. NQ442L2TVS212C 23520. or 31082. NQ442L2TVS216 27560. NQMB2KI 31157. NQ442L2TVS216C 27635. 28037. NQ472L2TVS212 27596. NQ442L4TVS212 31710. NQ442L4TVS216 24500. 23981. 28095. NQMB4LA 28166. NQ472L2TVS212C 24629. 27717. NQ442L4TVS212C 24102. 31832. NQ442L4TVS216C 28217.
225 A
42
225 A
72f
780.
MH74
113. NC74( )
400 A
42
MH80
a b c d e f
Select the appropriate main circuit breaker from tables starting on page 7-22 and add the circuit breaker price to the total price of the panelboard. C suffix indicates copper bussing. Embossed mounting holes add a .25 inch standoff to back of MH box. Add F for flush, S for surface. Enclosure includes trim kit. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
9-8
PE1A
Discount Schedule
NQ Merchandised Panelboards
www.schneider-electric.us
NQ Merchandised Accessories
Class 1640 / Refer to Catalog 1640CT0701
Table 9.13:
Mains Ampacity 100 225 400 600 a b
NQ Merchandised Neutrals
200% Neutral Kit Catalog No. NQNL1 NQNL2 or NQNL2ACCYb NQNL4a Price 315. 426. 639. Not Available Box Add no adder no adder Schedule PE-1A PE-1A Catalog No. NQN1CU NQN2CU NQN6CU NQN6CUa Copper 100% Neutral Kit Price 192. 585. Box Add no adder no adder Schedule PE-1A
Not to be used with SFL, FTL or SFB. These combinations are factory assembled only. For 225A panel with SFL, FTL or SFB, use NQNL2ACCY (enclosure size increases by 6 inches). Otherwise, use NQNL2.
Table 9.14:
Mains Ampacity 100 A 225 A 400 A 600 A
Note: See Table 9.15 & Table 9.16 for box selection table. a The final character L indicates the kit is used for Low circuit count interiors 30 and 42. b The final character H indicates the kit is used for High circuit count interiors 54, 72 and 84.
Table 9.15:
Feature Circuits 18 30 42 72 84 a
Table 9.16:
Feature Circuits 18 30 42 72 84 a
Box Selection Table: Merchandised NQ Vertically Mounted Main Breaker Panelboards w/ Accessories
Feed-through Lugs 100A 225 A MH50 MH62 MH68 400A MH62 MH68 MH80 MH80 600A Factory Asm. Only 100A Sub-feed Circuit Breakers 225 A (one) MH62 MH68 MH74 MH80 400A (two) MH86 MH86 a a 600A (two) Factory Asm. Only
Table 9.17:
NQ Accessories
Description Catalog No. QOB2125SL QOB3125SL PK27GTA PK23GTAL PK27GTACU PKGTAB NQFP15a NQ102OE NQ204OE NQ102S NQ204S NQ6RDE NQ12RDE NQ18RDE NQ24RDE PK49SP HLO1 QO1HT QO1PA QO1PL QO3HT QO1PAF QO2PAF QOGFI1PAF QOGFI2PAF QO70AN Q1100AN Q1150AN 8011010501 8011010401 $ Price 176.00 176.00 33.80 40.70 84.00 43.80 68.00 7.90 7.90 7.90 7.90 252.00 283.00 343.00 397.00 39.00 9.90 3.80 10.70 10.70 13.40 43.50 25.80 51.00 38.40 9.90 11.10 32.40 41.10 41.10 Schedule
Sub-feed (Bolt-on) 2-pole 3-pole Equipment Ground Bars Aluminum PK23GTA+ #1 to #4/0 Al or Cu lug Copper Ground Bar Insulator Kit Filler plate (15 per package) Circuit I.D. Number Strips 1102 odd/even (left side numbered 1,3,5 ...101) 103204 odd/even (left side numbered 103,105,107 ... 203) 1102 sequential (left side numbered 1,2,3 ... 102) 103204 sequential (left side numbered 103,104,105 ... 204) 6 in. Extension 12 in. Extension Rail & Deadfront Extensions 18 in. Extension 24 in. Extension Touch-up paint USAS #49 Gray (Aerosol can) Handle AttachmentsBranch Circuit Breakers Handle lock-off Handle tie - (QO and QOB only) Handle padlock attachment1-pole 2- and 3-pole Handle tie & lock-off for three 1-pole (QO, QOB) Handle Padlock Attachment for Padlocking in OFF position For padlocking 1P QO circuit breaker in OFF position only, fixed attachment For padlocking 2P and 3P QO circuit breaker in OFF position only, fixed attachment For padlocking 1P QO-GFI, QO-AFI, QO-CAFI and QO-EPD circuit breakers in OFF position only, fixed attachment For padlocking 2P QO-GFI and QO-EPD circuit breakers in OFF position only, fixed attachment Neutral or Ground Lugs #10 to #2 Al or #14 to #4 Cu #4 to #1/0 Al or Cu #1 to #4/0 Al or Cu Endwalls for MH Enclosures Blank (one per package) With Knockouts (one per package) a Filler Plates are $3.00 each and must be ordered in packages of 15.
DE2A
PE1A
DE1
DE2A
DE2E
DE3A
PE1A
PE1A
DE2A
DE2E
DE3A
Discount Schedule
9-9
PE-1A
PANELBOARDS
PE-1A
Table 9.19:
Ampere Rating a QOB Bolt-On
9
PANELBOARDS
Catalog No.
Catalog No. $ Price Catalog No.$ Price Catalog No. $ Price 240 Vac10 k AIR 48 Vdc5 k AIR j QOB310 293. QOB315 i 293. QOB320 i 293. QOB325 i 293. QOB330 i 293. QOB335 i 293. QOB340 i 293. QOB345 i 293. QOB350 i 293. QOB360 i 293. QOB370 ij 369. QOB380 ij 419. QOB390 ij 419. QOB3100 ij 419. QOB300 293. QOB3000 507.
QOB-GFIQOB QWIK-GARD Circuit Breaker With Ground Fault Circuit Interrupter UL Class A 46 mA People Protection. b 120/240 Vac 120 Vac10 k AIR 208Y/120 Vac10 k AIR 10 k AIR 15 QOB115GFI 248. QOB215GFI 444. QO315GFI 791. 20 QOB120GFI 248. QOB220GFI 444. QO320GFI 791. 25 QOB125GFI 248. QOB225GFI 444. 30 QOB130GFI 248. QOB230GFI 444. QO330GFI 791. 40 QOB240GFI 444. QO340GFI 791. 50 QOB250GFI 444. QO350GFI 791. 60 QOB260GFI c 444. QOB-VHGFI d 120 Vac22,000 AIR 15 QOB115VHGFI 497. 20 QOB120VHGFI 497. 25 QOB125VHGFI 497. 30 QOB130VHGFI 497. QOB-EPDQOB Equipment protection circuit breakers with UL Listed 30 mA (EPD) or 100 mA (EPE) equipment protection. 120 Vac 240 Vac10 k AIR 10,000 AIR 15 QOB115EPD 417. QOB215EPD 671. QO315EPDm 1077. QO315EPEm 1077. 20 QOB120EPD 417. QOB220EPD 671. QO320EPDm 1077. QO320EPE 1077. 25 QOB125EPD 417. QOB225EPD 671. 30 QOB130EPD 417. QOB230EPD 671. QO330EPDm 1077. QO330EPEm 1077. 40 QOB240EPD 671. QO340EPDm 1077. QO340EPEm 1077. 50 QOB250EPD 671. QO350EPDm 1077. QO350EPEm 1077. 60 QOB260EPD 671. QOB-HMHigh magnetic trip circuit breakers 15 QOB115HMe 39.80 20 QOB120HMe QOB-KKey operated QOB circuit breakers f 120 Vac10,000 AIR 10 QOB110K 168. 15 QOB115K 168. 20 QOB120K 168. 25 QOB125K 168. 30 QOB130K 168.
120 Vac10 k AIR 120/240 Vac10 k AIR 240 Vac 48 Vdc5 k AIR 48 Vdc5 k AIR j 10 k AIR 10 QOB110 39.80 QOB210 89. 15 QOB115ie 39.80 QOB215 i 89. QOB215H 240. 20 QOB120 ie 39.80 QOB220 i 89. QOB220H 240. 25 QOB125 i 39.80 QOB225 i 89. QOB225H 240. 30 QOB130 i 39.80 QOB230 i 89. QOB230H 240. 35 QOB135 i 39.80 QOB235 i 89. 40 QOB140 i 39.80 QOB240 i 89. QOB240H 240. 45 QOB145 i 39.80 QOB245 i 89. 50 QOB150 i 39.80 QOB250i 89. QOB250H 240. 60 QOB160 i 39.80 QOB260 i 89. QOB260H 240. 70 QOB170 i 78. QOB270 i 168. QOB270H 308. 80 QOB280 ij 240. QOB280H 366. 90 QOB290 ij 240. QOB290H 366. 100 QOB2100 ij 240. QOB2100H 366. 110 QOB2110 ij 501. 125 QOB2125 ij 501. 89. Molded Case Switch 60 A max 240 Vac QOB200 Molded Case Switch 100 A max 240 Vac QOB2000 234.
Table 9.20:
Ampere Rating a QOB-VH 15 20 25 30 40 50 60 70 80 90 100 110 125 150 QHB
120 Vac22,000 AIR QOB115VHie 72. QOB120VHie 72. QOB125VHi 72. QOB130VHi 72.
120/240 Vac 22,000 AIR QOB215VHi 171. QOB220VHi 171. QOB225VHi 171. QOB230VHi 171. QOB240VHi 171. QOB250VHi 171. QOB260VHi 171. QOB270VHi 273. QOB280VHi 384. QOB290VHi 384. QOB2100VHi 384. QOB2110VHi 1110. QOB2125VHi 1110. QOB2150VH k 1223.
240 Vac22,000 AIR QOB315VHi 440. QOB320VHi 440. QOB325VHi 440. QOB330VHi 440. QOB340VHi 440. QOB350VHi 440. QOB360VHi 440. QOB370VHi 560. QOB380VHi 629. QOB390VHi 629. QOB3100VHi 629. QOB3110VH k 1809. QOB3125VH k 1809. QOB3150VH k 1809. 240 Vac65,000 AIR QHB315i 596. QHB320i 596. QHB325i 596. QHB330i 596. 240 Vac10,000 AIR QOB315HID 327. QOB320HID 327. QOB325HID 327. QOB330HID 327. 2-pole3-Wire 3 Spaces120/240 Vac QOB310SWN 170. QOB315SWN 170. QOB320SWN 170. QOB325SWN 170. QOB330SWN 170. QOB340SWN 170. QOB350SWN 170.
120 Vac65,000 AIR 120 Vac/240 Vac65,000 AIR 15 QHB115i e 122. QHB215i 342. 20 QHB120i e 122. QHB220i 342. 25 QHB125i 122. QHB225i 342. 30 QHB130i 122. QHB230i 342. QOB-HIDHID circuit breakers g 120 Vac10,000 AIR 120/240 Vac10,000 AIR 15 QOB115HIDe 49.50 QOB215HID 108. 20 QOB120HID e 49.50 QOB220HID 108. 25 QOB125HID 49.50 QOB225HID 108. 30 QOB130HID 49.50 QOB230HID 108. 40 QOB140HID 49.50 QOB240HID 108. 50 QOB150HID 49.50 QOB250HID 108. QOB-SWNSwitch NeutralCommon TripNEC 514.11 1-pole2-Wire 2 Spaces 120 Vac QOB210SWN 116. QOB215SWN 116. QOB220SWN 116. QOB225SWN 116. QOB230SWN 116. QOB240SWN 116. QOB250SWN 116.
g h i j k l m
10 15 20 25 30 40 50
Table 9.21:
Breaker Type QOB 1-pole
Table 9.22:
QOB 2-pole
Catalog Number $ Price Catalog Number $ Price Combination 15 QOB115CAFI 306. QOB115VHCAFI 612. Arc-Fault 20 QOB120CAFI 306. QOB120VHCAFI 612. Interupter Note: See page 7-12 for accessories. a UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. b QO arc-fault circuit breakers provide branch feeder protection (i.e. QO115AFI) or combination protection (i.e. QO115CAFI) as required by the NEC and local code adoption, and comply with UL 1699. c 1030 A circuit breakers are suitable for use with 60 C or 75 C conductors. 3560 A circuit breakers are suitable for use with 75 C conductors.
1030 A circuit breakers are suitable for use with 60 C or 75 C conductors. 3560 A circuit breakers are suitable for use with 75 C conductors. Discount Schedule 2009 Schneider Electric All Rights Reserved
9-10
DE2A
Table 9.23:
Mains Rating 60 A 100 A 150 Ac 225 Ac
8680. 9672.
Table 9.24:
Circuit Breaker Ampere Rating
Table 9.25:
Circuit Breaker Ampere Rating
Specialty Branch Circuit Breakers (10,000 AIR) For High Intensity Discharge LightingQO-HID, QOB-HID 1530 78. 148. 376. 4050 78. 148. Switch NeutralQO-SWN, QOB-SWN 1-pole 2-pole 2-Wire 3-Wire 1550 (2 spaces) (3 spaces) 154. 220. High Magnetic Trip (For applications subject to high initial inrush) QO-HM, QOB-HM 1520 68.
Space Only All Space Only 28. 58. 58. 86. Except below QOBVH, Space 116. 174. Only (125150 A) 10,000 AIRBranch Circuit BreakersQO, QOB, QO-H, QOB-H 1560 68. 134. 260. a 352. 70 100. 208. 296. a 396. 80100 262. 380. a 458. 110125 482. 10,000 AIRCombination Arc Fault Circuit InterruptersQO-CAFI, QOB-CAFI 1520 470. 10,000 AIRQwikGardClass AQO-GFI, QOB-GFI Provided with a 5 mA setting on ground fault sensor 1530 272. 488. 920. 4050 488. 920. 60 488. 10,000 AIRQwikGardClass AQO-EPD, QOB-EPD Provided with a 30 mA setting on ground fault sensor 1530 462. 828. 1210. 4050 828. 1210. 60 828. 10,000 AIRQwikGardClass AQO-EPE, QOB-EPE Provided with a 100 mA setting on ground fault sensor 1530 1210. 4050 1210. (High Interrupting Capacity) 22,000 AIR Branch Circuit BreakersQO-VH, QOB-VH 1530 92. 212. 462. 3560 212. 462. 70 292. 556. 80100 378. 606. 110125 1022. 1746.b 150 1140. b 22,000 AIRCombination Arc Fault Circuit InterruptersQO-VHCAFI, QOB-VHCAFI 1520 940. 22,000 AIRQwik-GardClass AQO-VHGFI, QOB-VHGFI 1530 294. 42,000 AIR Branch Circuit BreakersQOH 3560 368. c 70 596. c 80100 688. c 110125 1402. c 65,000 AIR Branch Circuit BreakersQH, QHB 1530 144. 348. 596. Note: Shunt Trip, Auxiliary Switch, and Alarm Switchaccessories for circuit breakersadd $ Price from page 7-12. a UL Listed for use on 3, grounded B systems, (5,000 AIR for this application). b Bolt-On only, 2-pole requires 4 vertical spaces, 3-pole requires 6 vertical spaces. c Plug-On only.
Table 9.26:
(Refer to Cabinet Data table below for correct box size) No. of Ampacity QB QD QG a HD HG a JD JG a Poles 2 110225 A 1218. 1762. 3812. 2456. 3500. 3020. 4220. 3 110225 A 1848. 2296. 4608. 2872. 3798. 3370. 5100. Space 110225 A 826. 826. 826. 826. 826. 826. 826. a QJ, HJ, HL, JJ and JL circuit breakers are also available.
Table 9.27:
Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces)
Main Main Main Main Main Circuit Circuit Circuit Lug Lug Breaker Breaker Breaker 30 50 62 74 86 74 42 56 68 80 86 80 not 54 56 68 80 80 available with MCB 72 62 74 86 86 84 68 80 Not Available in Type 3R, 5, 12 if subfeed breaker is over 150 A.
PE1
Discount Schedule
9-11
250 Ac JG 5040. 6020. 400 Ac 1422. 1634. LH 7708. 8834. 600 Abc 2082. 2326. Note: Equipment Ground Bar38. a QL, HJ, HL, JJ and JL circuit breakers are also available. b Copper bus standard c Prices are for 54-circuit and less interiors. Consult the Product Selector for 72- and 84-circuit interior pricing.
PANELBOARDS
Common Features
Class 1640 / Refer to Catalog 1640CT0701
www.schneider-electric.us
Table 9.37:
9
PANELBOARDS
Price per Panel one #6-2/0 Al or Cu one #6-2/0 Al or Cu $128. one 1/0-350 kcmil Al or Cu one 1/0-350 kcmil Al or Cu $128. one 1/0-750 kcmil Cu only one 1/0-750 kcmil Cu only $164.
Panelboard Actual Lug Wire Neutral Conductors Required Ampacity Range 100/125 (2) 1/0 Cu or Al (2) #4-300kcmil 225 (2) 4/0 Cu or (2) 300 kcmil Al (2) #4-300 kcmil (4) 3/0 Cu or (4) 250 kcmil Al (2) 1/0-300 kcmil or 400 A (2) 600 kcmil Cu (1) 750 kcmil (2) 750 kcmil Al Note: Neutral conductors must be of size and quantity per table above.
Table 9.29:
Max. No. of Branch Spaces 18 30 42 72 84
Table 9.38:
Table 9.39:
Hinged Door-in-Door Trim Hinged Door-in-Door Trim has piano hinge down one side. Inner door has a lock, outer door is retained with screws Hinged Door-in-Door with Outer Door Lock in place of screws
Feed-through Lugs
Table 9.30:
Mains Rating 100 A 225 A 400 A 600 A
Feed-through Lugs
Feed-Through Wire Range Per Phase $ Price 344. 344. 826. 826.
Table 9.40:
one #6-2/0 Al or Cu one #6350 kcmil Al or Cu one 1/0750 kcmil or two 1/0350 kcmil Al or Cu two 1/0750 kcmil Al or Cu
Weatherproof or Dusttight Cabinets Note: 600 A LC main circuit breaker NQ panelboards are not available with a weatherproof enclosure (Use I-Line) 400 and 600 A NQ panelboards with sub-feed circuit breakers are not available with a weatherproof enclosure (Use I-Line).
1516.
Table 9.31:
Max. No. of Branch Spaces 225 A Main Lugs 38 38 50 56
Table 9.41:
Main Lug Interiors: Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs
30 42 72 84 a
Table 9.42:
Table 9.32:
Ground Bars
Ground Bars
$ Price Adder 38. 52. 86. Main Circuit Breaker Interiors:
Equipment Ground Bar Copper Ground Bar (Add to Equipment Ground Bar Price) Insulated/Isolated Ground Bar (Add to Equipment Ground Bar Price)
H Frame J Frame LA Frame LC Frame Aluminum Compression Lugs 58. 98. 148. 148. Copper Mechanical Lugs 70. 108. 148. 168. Copper Compression Lugs 70. 108. 148. 168. Note: Optional lugs are not available for Q frame main or QOB circuit breakers
Table 9.33:
Name Plates
Name Plates
$ Price Adder 78.
Table 9.43:
Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive backed or screw mountable with screws in a bag assembly (Price includes engraving)
Table 9.34:
Copper Bus Bars 100 A, 225 A, 250 A 400 A 600 A
Copper Neutrals
$ Price Adder 132.
Description Surge Counter Dry Contacts Remote Monitor Note: Additional factory modifications, see 9-37.
Table 9.36:
Panelboards with 200% rated neutrals are not available with 250 A J- and K-frame main circuit breakers or integral lighting contactors 100 Aa one #6-2/0 kcmil Al or Cu per lug 225 Aa one #6-350 kcmil Al or Cu per lug #1/0-750 kcmil Al or 400 Aa one 1/0-300 kcmil per lug Cu per lug or two a Two incoming neutral lugs per panel
9-12
PE1
Discount Schedule
NF Merchandised Panelboards
Class 1670 / Refer to Catalog 1670CT0701
www.schneider-electric.us
NF Main Lug Interiors Use I-LINE Panelboards on 480 V 33W DELTA Applications
NEMA 1 Enclosure $ Total Price a Interior Only b Box 20 in. W x 5.75 in. D d $ Price Mono-Flat Front e Catalog No. $ Price Hinged Front Catalog No. NC26( )HR NC26( )HR NC32( )HR NC32( )HR NC38( )HR NC38( )HR NC44( )HR NC44( )HR NC62( )HR NC62( )HR NC50V( )HR NC50V( )HR NC56V( )HR NC56V( )HR NC74V( )HR NC74V( )HR NC86V( )HR NC86V( )HR NC50V( )HR NC56V( )HR NC74V( )HR NC86V( )HR $ Price NEMA 3R, 5, 12 Enclosure f Enclosure 20 in. W x 6.5 in. D Height (In.) Catalog No. $ Price MH26WP MH26WP MH32WP MH32WP MH38WP MH38WP MH44WP MH44WP MH62WP MH62WP MH50WP MH50WP MH56WP MH56WP MH74WP MH74WP MH86WP MH86WP Factory Assembled Only
NEMA NEMA 1 Catalog No. c $ Price Catalog No. 3R, 5, 12 (Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire 2056. 3638. NF418L1 1446. MH26 18 125 2448. 4030. NF418L1C 1838. MH26 2406. 3970. NF430L1 1766. MH32 30 125 2802. 4366. NF430L1C 2162. MH32 2881. 4435. NF430L2 2219. MH38 30 250 3286. 4840. NF430L2C 2624. MH38 3194. 5021. NF442L2 2418. MH44 42 250 3602. 5429. NF442L2C 2826. MH44 4800. 6485. NF466L2 3800. MH62 66g 250 5442. 7127. NF466L2C 4442. MH62 3308. 5075. NF430L4 2466. MH50 30 400 3716. 5483. NF430L4C 2874. MH50 3572. 5325. NF442L4 2673. MH56 42 400 3895. 5648. NF442L4C 2996. MH56 5285. 6957. NF466L4 4200. MH74 66g 400 5792. 7464. NF466L4C 4707. MH74 6524. 8261. NF484L4 5346. MH86 84g 400 7169. 8906. NF484L4C 5991. MH86 30 600 3838. NF430L6C 2996. MH50 42 600 4087. NF442L6C 3188. MH56 66g 600 6094. NF466L6C 5009. MH74 84g 600 7553. NF484L6C 6375. MH86 800
Mains Rating
NC26( ) 497. NC26( ) NC32( ) 113. 527. NC32( ) NC38( ) 113. 549. NC38( ) NC44( ) 113. 663. NC44( ) NC62( ) 113. 887. NC62( ) NC50V( ) 113. 729. NC50V( ) NC56V( ) 113. 786. NC56V( ) NC74V( ) 113. 972. NC74V( ) NC86V( ) 113. 1065. NC86V( ) 113. NC50V( ) 729. 113. NC56V( ) 786. 113. NC74V( ) 972. 113. NC86V( ) 1065. FACTORY ASSEMBLED ONLY 113.
620. 657. 687. 830. 887. 912. 983. 1215. 1430. 912. 983. 1215. 1430.
26 32 38 44 62 50 56 74 86 50 56 74 86
NOTE: For footnotes, see Table 9.46 footnotes. Table 9.46: NF Main Circuit Breaker Interiors Use I-LINE Panelboards on 480 V 33W DELTA Applications
NEMA 1 Enclosure NEMA 3R, 5, 12 Enclosure f Max. No. of Main Circuit Main $ Total Price a Interior Only b One-pole Mains Box Enclosure Breaker Adapter Kit Circuit Hinged Front EDB 20 in. W x 5.75in. D d Mono-Flat Front e 20 in. W x 6.5 in. D Height Breaker Circuit Rating (In.) NEMA NEMA 1 Kit $ Price Frame Catalog No. c $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Breakers 3R, 5, 12 (Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire 2056. 3638. NF418L1 1446. MH26 NC26( ) NC26( )HR MH26WP 15 125 113. 497. 620. 2192. 26 2448. 4030. Back-fed 1838. MH26 NC26( ) NC26( )HR MH26WP EDB, EGB NF418L1C Main or EJB 2406. 3970. Breakerh NF430L1 1766. MH32 NC32( ) NC32( )HR MH32WP 27 125 113. 527. 657. 2204. 32 2802. 4366. NF430L1C 2162. MH32 NC32( ) NC32( )HR MH32WP 2888. 4442. NF418L1 1446. MH38 NC38( ) NC38( )HR MH38WP 18 125 113. 549. 687. 2216. 38 HD/HG/ 3280. 4834. N150MH NF418L1C 1838. MH38 NC38( ) NC38( )HR MH38WP or 780. HJ/HL 3322. 5149. N100MFIi NF430L1 1766. MH44 NC44( ) NC44( )HR MH44WP or FI 30 125 113. 663. 830. 2603. 44 3718. 5545. NF430L1C 2162. MH44 NC44( ) NC44( )HR MH44WP 3841. 5608. NF430L2 2219. MH50 NC50( ) NC50( )HR MH50WP 30 250 780. 113. 729. 912. 2609. 50 4246. 6013. NF430L2C 2624. MH50 NC50( ) NC50( )HR MH50WP JD/JG/ 4097. 5850. N250MJ NF442L2 2418. MH56 NC56( ) NC56( )HR MH56WP 42 250 or 780. JJ/JL 113. 786. 983. 2652. 56 4505. 6258. N250MKCi NF442L2C 2826. MH56 NC56( ) NC56( )HR MH56WP or KI 5665. 7337. NF466L2 3800. MH74 NC74( ) NC74( )HR MH74WP 66g 250 780. 113. 972. 1215. 2757. 74 6307. 7979. NF466L2C 4442. MH74 NC74( ) NC74( )HR MH74WP 4246. 5931. NF430L4 2466. MH62 NC62V( ) NC62V( )HR MH62WP 30 400 N400Mi 780. LA/LH 113. 887. 1109. 2685. 62 4654. 6339. NF430L4C 2874. MH62 NC62V( ) NC62V( )HR MH62WP (LC and LI 4514. 6195. NF442L4 2673. MH68 NC68V( ) NC68V( )HR MH68WP 42 400 N400Mi 780. factory 113. 948. 1185. 2742. 68 4837. 6518. 2996. MH68 NC68V( ) NC68V( )HR MH68WP assembled NF442L4C 6158. 7895. NF466L4 4200. MH86 NC86V( ) NC86V( )HR MH86WP only) 66g 400 N400Mi 780. 113. 1065. 1430. 2915. 86 6665. 8402. NF466L4C 4707. MH86 NC86V( ) NC86V( )HR MH86WP a b c d e f g h i Total Price includes: interior, front, main circuit breaker adapter kit, and enclosure. Order branch circuit breakers separately. C suffix indicates copper bussing. Embossed mounting holes add a .25 inch standoff to back of MH box. Add F for flush, S for surface. Enclosure includes trim kit. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. Back-fed EDB 125 A 3 pole main circuit breaker must be ordered separately and field installed. Maximum breaker rating opposite is 20A. Select the appropriate main circuit breaker from pages starting on 7-21 and add the circuit breaker Price to the total Price of the panelboard.
Table 9.47:
Mains Rating 250 A 250 A 400 A 400 A Max. Breaker Spaces 42 42 42 42
NF Merchandised Interiors with TVSS Use I-LINE Panelboards on 480 V 33W DELTA Applications
TVSS Ratings Voltage 480Y/277 3P4W Surge Rating 120 160 120 160 Interior Catalog No. NF442L2TVS412 NF442L2TVS412C NF442L2TVS416 NF442L2TVS416C NF442L4TVS412 NF442L4TVS412C NF442L4TVS416 NF442L4TVS416C $ Price 30141. 30504. 34256. 34664. 30396. 30719. 34511. 34833. Components for adding Vertical Main Circuit Breaker MCB Kit Main Circuit Breaker Frame Select the appropriate MCB and price Catalog No. $ Price from the tables starting on page 7-22 N250MJ or N250MKC N400M N400M 780. 780. 780. 780. JD/G/J/L or KI JD/G/J/L or KI LAL/LHL (LC and LI F/A only)
480Y/277 3P4W
Table 9.48:
Mains Rating 250A 400 A Max. Breaker Spaces 42 42
PE1A
9-13
PANELBOARDS
NF Merchandised Panelboards
Table 9.49:
Mains Ampacity
Accessories
Class 1670 / Refer to Catalog 1670CT0701
www.schneider-electric.us
NF Merchandised Neutrals
200% Neutral Kit Copper 100% Neutral Kit $ Price 405. 1148. Box Add No Adder No Adder Schedule PE-1A PE-1A
9
PANELBOARDS
$ Price Box Add Schedule Catalog No. 125 1029. NFN1CU No Adder PE-1A 250 1277. NFN2CU 400 1914. No Adder PE-1A NFN6CU 600 Factory Assembled Only NFN6CUa a Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only.
Table 9.50:
Mains Ampacity
$ Price Schedule Catalog No. 167. 213. 356. PE-1A PE-1A PE-1A NF125FTL NF250FTL NF400FTL e
PE1A
FACTORY ASSEMBLED ONLY 800 Note: NF250SFBH and NF600SFBH are for use with HDL, HGL, HJL, and HLL circuit breakers. NF600SFBJ are for use with JDL, JGL, JJL, and JLL circuit breakers. a Available factory assembled only on non-linear panelboards. b Select box from the Box Selection Table. c Order appropriate circuit breaker. d Use copper wire only. e Available factory assembled only.
Table 9.51:
Feature No. of Ckts Ampacity 100/125 250 400 600 800 a
Table 9.52:
Feature No. of Ckts Ampacity 100/125 250 400a 600 a
Table 9.53:
Ampacity 125 250 400 600 800 a b c
Use copper wire only. Use of this kit requires an additional 6 in. added to box height. Use of this kit to terminate larger than standard wire size requires an additional 6 in. added to box height.
Table 9.54:
NF Accessories
Catalog No. PK27GTA PK27GTACU PK23GTAL PKGTAB NF102OE NF204OE NF102S NF204S NF6RDE NF12RDE NF18RDE $ Price Schedule 33.80 DE-3A 84.00 PE-1A 40.70 DE-3A 43.80 Description Filler plate (15 per package) EXB Fixed padlock attachment, Lock ON/OFF for ED, EG & EJ Circuit Breakers 1, 2, or 3 poles EXB Fixed padlock attachment, Lock OFF only for ED, EG & EJ Circuit Breakers 1, 2, or 3 poles Oversized Lugs for Neutral or Ground Bar #10 to #2 Al or #14 to #4 Cu #4 to #1/0 Al or Cu #1 to #4/0 Al or Cu Drip Hood for 20 in. wide enclosures Catalog No. $ Price Schedule NFFP15 113.00a PE-1A EDPA EDPAF 26.00 30.00 DE-2 DE-2
Description Aluminum Equipment Ground Bar Copper Equipment Ground Bar Large Aluminum Lug for Equipment Ground Bar Equipment Ground Bar Insulator Kit Circuit I.D. number strips 1102 odd/even (left side numbered 1,3,5 ...101) 103204 odd/even (left side numbered 103,105,107 ... 203) 1102 sequential (left side numbered 1,2,3 ... 102) 103204 sequential (left side numbered 103,104,105 ... 204) Rail and Deadfront Extensions 6 in. Extension 12 in. Extension 18 in. Extension a
7.90
PE-1A
DE-3A PE-1A
PE-1A
Filler plates are $7.50 each and must be ordered in packages of 15.
9-14
PE1A
DE3A
DE1
Discount Schedule
Circuit Breakers
www.schneider-electric.us
Table 9.55:
Ampere Rating
ED, EG, EJ (480Y/277 Vac) Hold Trip 1-pole, 277 Vac 15 20 270 875 25 30 35 40 45 630 1800 50 60 70 2-pole, 480Y/277 Vac c 15 20 270 875 25
150.
255.
408.
150. 302.
225. 507.
408. 812.
AL100FD #142/0 Al or Cu
536.
776.
1241.
30 35 40 AL100FD 536. 776. 1241. 45 630 1800 #142/0 50 Al or Cu 60 70 756. 1280. 2048. 80 756. 1280. 2135. 90 AL100FD 100 1000 2300 #142/0 Al or Cu 110 1946. 2586. 3879. 125 3-pole, 480Y/277 Vac 15 EDB34015b EGB34015b EJB34015b AL30FD 20 EDB34020b EGB34020b EJB34020b 270 875 669. 1131. 1358. #14#6 25 EDB34025b EGB34025b EJB34025b Al or Cu 30 EDB34030b EGB34030b EJB34030b 35 EDB34035b EGB34035b EJB34035b 40 EDB34040b EGB34040b EJB34040b AL100FD 45 EDB34045b 669. EGB34045b 1131. EJB34045b 1358. 630 1800 #142/0 50 EDB34050b EGB34050b EJB34050b Al or Cu 60 EDB34060 EGB34060 EJB34060 70 EDB34070 911. EGB34070 1292. EJB34070 2562. 80 EDB34080 EGB34080 EJB34080 911. 1292. 2562. 90 EDB34090 EGB34090 EJB34090 AL100FD 100 1000 2300 EDB34100 EGB34100 EJB34100 #142/0 Al or Cu 110 EDB34110 EGB34110 EJB34110 2421. 3216. 4826. 125 EDB34125 EGB34125 EJB34125 EPDs (Equipment Protection Devices), 1-pole, 277 Vac, Thermal-magnetic with 30 mA ground-fault protectiond 15 EDB14015EPDab EGB14015EPDab EJB14015EPDab 20 270 875 EDB14020EPDab 1151. EGB14020EPDab 1256. EJB14020EPDab 1409. #14#6 Cu 30 EDB14030EPDb EGB14030EPDb EJB14030EPDb or #12#4 Al 40 EDB14040EPDb EGB14040EPDb EJB14040EPDb 630 1800 1151. 1256. 1409. 50 EDB14050EPDb EGB14050EPDb EJB14050EPDb Note: All EDB, EGB, and EJB circuit breakers are UL Listed as HACR Type. For 50 oC calibration, use a CA suffix. NF branch circuit breakers are fungus proof as standard. a UL Listed as SWD (Switching duty rated). b UL Listed as HID (High Intensity Discharge rated). c UL Listed for use on 240 V Corner-grounded Delta Systems (Grounded B Phase). See: 2700DB0202. d All EPDs occupy two spaces, with or without Alarm Switch option. For alarm switch add 158 list Price and the suffix BA.
AL30FD #14#6 Al or Cu
Table 9.56:
Monitors circuit breaker contact status and provides Used with control circuits and is actuated a remote signal indicating the circuit breaker only when the circuit breaker has tripped. contacts are OPEN or CLOSED. APPLICATION APPLICATION Max Load = Max Load = 7 A @ 120 Vac 50/60 Hz 10 A @ 120 Vac 50/60 Hz Terminals for #14 AWG Cu wire. Terminals for #14 AWG Cu wire
Shunt Trip Trips the circuit breaker from a remote location by means of a coil energized from a separate circuit. A 120 V shunt trip will operate at 55% or more of rated voltage. APPLICATION For use with momentary or maintained push button. 120 Vac 50/60 Hz Terminals for #14 AWG Cu wire.
Table 9.57:
Factory Installed Electrical Accessory Packages for ED, EG, EJ Circuit Breakers
$ Price 312. 755. 1067. 237.
Table 9.59:
Handle Accessories
$ Price 39.00 45.00 25.50 16.80 17.85
Accessory Package Suffix Auxiliary Switch/Alarm Switch Packageab AABA Shunt Trip Packageab SA Auxiliary Switch/Alarm AABASA Alarm Switch (N.O.) Package for EPDs only BA a Accessory package takes an additional pole space. b Not available for EPD.
Table 9.58:
Circuit Breaker Type No. of Poles Catalog No. EXB Fixed Padlock Attachment, Lock ON/OFF ED, EG, EJ 1, 2, or 3 EDPA EXB Fixed padlock attachment, Lock OFF only ED, EG, EJ 1, 2, or 3 EDPAF EXB Removable padlock attachment, Lock OFF only ED, EG, EJ 1, 2, or 3 HPAFD EXB Handle Ties Ties 2 1P EGB2HT ED, EG, EJ Ties 3 1P EGB3HT
Table 9.60:
120 V 240 V 480Y/277 V
Table 9.61:
EDB, EGB, EJB 2-pole 15125 Amperes
Standard EDB, EGB, EJB
Mechanical Lug Kit Information (Al lugs for use with Al or Cu wire)
Circuit Breaker Application Ampere Rating Optional 1530 35125 EDB, EGB, EJB Ampere Rating 1530a Number of Wires Per Lug and Wire Range one #12#6 AWG Al or one #14#6 AWG Cu one #122/0 AWG Al or one #142/0 AWG Cu one #141/0 AWG Cu Catalog Number AL30FD AL100FD CU100FD Lugs Per Kit 3 3 3 41.30 $ price Per Kit
EDB, EGB, EJB 15125 a Factory installed only. Use suffix LH Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages starting on 7-55 2009 Schneider Electric All Rights Reserved
DE2
Discount Schedule
9-15
PANELBOARDS
AL30FD #14#6 Al or Cu
9
PANELBOARDS
Table 9.62:
Max. No. of Poles Mains Rating
Table 9.64:
Max. No. Mains of Poles Rating
1 Phase 3-Wire Main Lugs Only 30 225 1669. NQ830L2C Main Circuit Breaker2-pole 20 100 1818. NQ820B1C 3 Phase 4-Wire Main Lugs Only 30 100 1608. NQ8430L1C 42 225 1938. NQ8442L2C Main Circuit Breaker3-pole 30 100 2363. NQ8430B1C 42 225 4961. NQ8442B2C a 60 A Maximum BranchCopper Bus Standard.
Main Lugs Only3 Phase 4-Wire 30 125 2410. 42 225 3281. Main Circuit Breaker3-pole 30 42 100 225 3767. 6660.
Table 9.63:
Table 9.65:
42
MPX81542
479.
42
MPX81542
479.
Cable troughs are standard with a trough barrier. Box width = 8.625 in., width at front, including flange, is 9.625 in..
20"
15"
Cable Trough
858"
9-16
PE1A
Discount Schedule
100 A 225 A
Note: Copper bus standard. Equipment Ground Bar $ Price adder$38.00. Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder$52.00.
Table 9.67:
$ Price
$ Price
Space Only All Space Only Except Below 28. 58. 10,000 AIRBranch Circuit BreakersQOB, QOB-H 1560 68. 134. 10,000 AIRQWIK-GUARDClass AQOB-GFI 1530 272. 488. 4060 488. Specialty Branch Circuit Breakers (10,000 AIR) For High Intensity Discharge LightingQO-HID, QOB-HID 1530 78. 148. 4050 78. 148. High Magnetic Trip (For applications subject to high initial inrush)QO-HM, QOB-HN 1520 68. Provides 30 mA Equipment ProtectionQO-EPD, QOB-EPD 1530 462. 828. (High Interrupting Capacity) 22,000 AIR Branch Circuit BreakersQO-VH, QOB-VH 1530 92. 212. 3560 212. 22,000 AIRQWIK-GUARDClass AQO-VHGFI, QOB-VHGFI 1530 294.
376.
462. 462.
2-Pole
3-Pole
FA 2184. FH 100 A 1074. 2842. HD HG 125 A 3222. 150 A HD 3222. HG 1272. 225 A JD 4784. JG Note: Copper busstandard. Copper Neutral $ Price adder$132.00. Equipment Ground Bar $ Price adder$38.00. Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder$52.00.
Table 9.69:
Circuit Breaker Ampere Rating 1560 A Space Only
Table 9.70:
Circuit Breaker Ampere Rating 1560 A
PE-1
Discount Schedule
9-17
PANELBOARDS
NF Panelboards a
9
Table 9.71:
Mains Rating Main Lugs 2-pole 100 A 100 A 125 A 150 A 225 A d 250 A d 400 A d 600 A de 800 A e a b c d e 846. 1002 1326. 2366. 3550. 3-pole 972. 1152. 1524. 2622. 3900.
PANELBOARDS
HL and JL frame circuit breakers are also available as main circuit breakers. Contact the Square D/Schneider Electric local Field Sales Office for Micrologic trip main circuit breaker pricing. Back-fed main circuit breaker. Prices are for 54 ckts and less. Consult the Product Selector for 66 and 84 ckt interior pricing. Copper bus only.
Table 9.72:
Circuit Breaker Ampere Rating
1-pole 2-pole $ Price $ Price 324. 1560 A 192. 442. 748. 746. 70 A 342. 872. 1046. 578. 1474. 80100 A 872. 1046. 1474. 110125 A 2210. 2724. 4114. Space Only 42. 84. 126. 42. 84. Note: All ED, EG and EJ branch circuit breakers are UL Listed as HACR type.
Table 9.73:
Circuit Breaker Ampere Rating
1560 A a b
All 1-pole EDB-EPD branches use 2 poles of mounting space. For bell alarm in EDB-EPD branch breaker, add 158. to branch breaker price.
Table 9.74:
No. of Poles 2 3 a
Table 9.75:
Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces) 30 42 54 66 84 a b c d
600 A main lug panelboards require a 8.75 in. deep box. 600 A main circuit breaker panelboards require an 8 in. deep, 26 in. wide box. 800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box. Dimensions also for 400 A LC/LI main circuit breaker panels.
9-18
PE1
Discount Schedule
Common Features
Class 1670 / Refer to Catalog 1670CT9601 Table 9.84: 200% Rated Neutrals
Table 9.76:
An additional mains end termination point that can be used to feed out to another panelboard or device from the incoming service lines.
Table 9.85:
Panelboard Ampacity 125 250 400 A 600 800 A a 74 80 86
Table 9.77:
Max. No. of Branch Spaces 12 18 30 42 54 a
Table 9.86:
Metal Directory Frame Not available with LC/LI main circuit breaker (Replaces standard plastic stick-on directory pouch)
Table 9.78:
Table 9.87:
A second set of lugs assembled at the opposite end from the mains of the panelboard. Often used to connect another panelboard or device to the incoming lines. Available on main lugs and main circuit breaker panelboards.
Mains Rating 125 A 250 A 400 A 600 A Feed-through Wire Range Wire Bending Space per NEC Table 373-6 one #62/0 kcmil Al or Cu one #6350 kcmil Al or Cu one 1/0750 kcmil or two 1/0350 kcmil Al or Cu two 1/0600 kcmil Al or Cu $ Price 344. 344. 826. 826.
Hinged Door-in-Door Trim has piano hinge down one side. Inner door has a lock, outer door is retained with screws Hinged Door-in-Door with Outer Door Lock in place of screws
Table 9.88:
Weatherproof or Dusttight Cabinets Type 3R, 5, 12 (Not available with panelboards having LC/LE/LI/LX/LXI main circuit breakers)
Table 9.79:
Max. No. of Branch Spaces
Table 9.89:
125 A
Main Lug Interiors: Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs
12 18 30 42 54 a b c
Main Main Breaker Main Main Main Main Main Main (Back-fed Lugs Breaker Lugs Breaker Lugs Breaker Lugs a only) 32 44 38 32 44 44 38 50 50 62 56 68 56 50 56 68 62 74 62 62 74 68 80 68
Table 9.90:
Main Circuit Breaker Interiors: Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs
600 A main lug panelboards require a 26 in. wide box. 600 A main circuit breaker panelboards require an 8 in. deep, 26 in. wide box. 800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box.
Table 9.80:
Ground Bars
Ground Bars
$ Price Adder Equipment Ground Bar 38. Copper Ground Bar (Add to Equipment Ground Bar Price) 52. Insulated/Isolated Ground Bar (Add to Equipment Ground Bar Price) 86.
Table 9.91:
Surge Current Rating kA 100 120 160 200 240 a
Table 9.81:
Name Plates
$ Price Adder 78.
Name Plates Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive backed or screw mountable with screws in a bag assembly (Price includes engraving)
Panelboard box height with TVSS unitContact the Square D/Schneider Electric local Field Sales Office.
Table 9.82:
100 A, 250 A 400 A 600 A, 800 A
Table 9.92:
Table 9.83:
100600 A 800 A
Copper Neutral
$ Price Adder 132. 176.
Copper Neutral
PE1
Discount Schedule
9-19
Note: Neutral conductors must be of size and quantity per table above.
PANELBOARDS
Panelboards with 200% rated neutrals are available with Add Per Panel sub-feed lugs, feed-through lugs, and main circuit breakers $ Price 250 A 769. 400 A 950. 600 A 1262. 800 A 1894.
9
PANELBOARDS
3. 4. 5. 6.
Table 9.93:
600 Vac, 33W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door. Description 400 Amp MLO Interior 4 Piece Surface Trim Without Door Type 1 Enclosure (8) 60/3 one 100/2 one 4.5 in. Blanks one 1.5 in. Blank
Table 9.94:
600 Vac, 33W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door. Description 400 A MLO Base Price (8) 60/3 one 100/2 (3) 250/3
Table 9.95:
600 Vac, 33W, 400 A, Fusible 10k AIR, Type 1 Enclosure Branches 400 A MLO Base Price (4) 60/3 one 100/3 one 30/3
9-20
Discount Schedule
TYPE HCN
225 A max. (240 V max.) branch circuit breaker QB, QD, QG, QJ 150 A max. branch circuit breaker FA, FH, FY, HD, HG, HJ, HL l
Table 9.96:
Mains Ampere Rating Total Circuit Breaker Mounting Space (In.)
(100 A and 225 A interiors include solid neutral, all others without solid neutral. Order solid neutral from 9-23) Complete Front a Box c Surface $ Price Interior Assembly (4 Piece Trim) NEMA (Less Branch 4 Piece Trim (Less Branch Trim With Door Type 1 3R/5/12 d Circuit Breakers) Without Door b Circuit (Includes Front) Breakers) Type Type 1 3R/ Catalog Catalog Catalog Catalog Catalog $ Price $ Price $ Price Number $ Price Number $ Price $ Price 5/12 Number Number Number $ Price HCN Main Lugs Only 3-poleSuitable for use as service equipment when provided with a main circuit breaker. i 225 2171. 4004. HCN14522N 1593. HC2652B HC2652WP 27 400 2195. 4028. HCN14524 1617. HCN52T( ) 335. HCN52T( )D 411. 243. 2411. 600 2392. 4225. HCN14526 1814. 225 2674. 4402. HCN23652N 1991. HC2665B HC2665WP 45 400 2702. 4430. HCN23654 2019. HCN65T( ) 440. HCN65T( )D 530. 243. 2411. 600 2960. 4688. HCN23656 2277. 225 3135. 4709. HCN32742N 2298. HC2674B HC2674WP 63 400 3156. 4730. HCN32744 2319. HCN74T( ) 594. HCN74T( )D 717. 243. 2411. 600 3396. 4970. HCN32746 2559. 225 3548. 6233. HCN41832N 2552. HC2683B HC2683WP 81 400 3564. 6249. HCN41834 2568. HCN83T( ) 753. HCN83T( )D 890. 243. 3681. 600 3824. 6509. HCN41836 2828. 225 4175. 6767. HCN50922N 3086. HC2692B HC2692WP 99 400 4341. 6933. HCN50924 3252. HCN92T( ) 846. HCN92T( )D 1001. 243. 3681. 600 4434. 7026. HCN50926 3345. HCN Main Circuit Breaker e k Includes 3-pole, vertically mounted main circuit breakerSuitable for use as service equipment 27 400 6649. 8377. HCN14654M 5966. HC2665B 100 3860. 5588. HCN18651MN 3177. HCN65T( ) 440. HCN65T( )D 530. 243. HC2665WP 2411. 36 225 5303. 7031. HCN18652MN 4620. 45 400 7287. 8861. HCN23744M 6450. 100 4323. 5897. HCN27741MN 3486. HCN74T( ) 594. HCN74T( )D 717. HC2674B 243. HC2674WP 2411. 54 225 5759. 7333. HCN27742MN 4922. 225 6068. 8753. HCN32832MN 5072. HCN83T( )D 890. HC2683B 243. HC2683WP 3681. 63 HCN83T( ) 753. 400 7836. 10521. HCN32834M 6840. 81 400 8154. 10746. HCN41924M 7065. HCN92T( ) 846. HCN92T( )D 1001. HC2692B 243. HC2692WP 3681. 90 225 6590. 9182. HCN45922M 5501. HCM Main Lugs Only 3-poleSuitable for use as service equipment when provided with a main circuit breaker. i 225 2279. 4566. HCM14482N 1644. HC3248B HC3248WP 400 2404. 4691. HCM14484 1769. 27 HCM48T( ) 392. HCM48T( )D 483. 243. 2922. 600 3175. 5462. HCM14486 2540. 800 3709. 5996. HCM14488 3074. 225 2795. 5717. HCM23642N 2036. HC3264B HC3264WP 400 2891. 5813. HCM23644 2132. 45 HCM64T( ) 516. HCM64T( )D 633. 243. 3681. 600 3530. 6452. HCM23646 2771. 800 4041. 6963. HCM23648 3282. 225 3263. 6002. HCM32732N 2321. HC3273B HC3273WP 400 3350. 6089. HCM32734 2408. 63 HCM73T( ) 699. HCM73T( )D 864. 243. 3681. 600 3921. 6660. HCM32736 2979. 800 4644. 7383. HCM32738 3702. 225 4205. 7918. HCM50912N 2966. HC3291B HC3291WP 400 4281. 7994. HCM50914 3042. 99 HCM91T( ) 996. HCM91T( )D 1217. 243. 4952. 600 4586. 8299. HCM50916 3347. 800 5321. 9034. HCM50918 4082. HCM Main Circuit Breaker e k Includes 3-pole, vertically mounted main circuit breakerSuitable for use as service equipment. 27 400 7563. 10485. HCM14644M 6804. HCM64T( ) 516. HCM64T( )D 633. HC3264B 243. HC3264WP 3681. 225 5582. 8504. HCM18642MN 4823. 36 600 11648. 10706. HCM18736MP 10706. HC3273DB9m 243. HCM73T( ) 699. HCM73T( )D 864. Use HCP 800 14549. 13607. HCM18738MP 13607. 45 400 8007. 10746. HCM23734M 7065. HCM73T( ) 699. HCM73T( )D 864. HC3273B 243. HC3273WP 3681. 54 225 5969. 8708. HCM27732MN 5027. 600 12377. 11138. HCM36916MP 11138. HC3291DB9m 243. 72 HCM91T( ) 996. HCM91T( )D 1217. Use HCP 800 15431. 14192. HCM36918MP 14192. 81 400 9315. 13028. HCM41914M 8076. HCM91T( ) 996. HCM91T( )D 1217. HC3291B 243. HC3291WP 4952. HCP-SU g Universal Single Row Main Lugs or Main Circuit Breaker k 3-poleSuitable for use as service equipment when provided with a main circuit breaker. i 54 800 5858. 9466. HCP54868SU 4514. HC2686T( )4P 1101. HC2686T( )HRf 1658. HC2686DB 243. HC2886WP 4952. a b c d e f g h i Box Height (In.) 52 65 74 83 92 65 74 83 92 48 64 73 91 64 73 91 86
S N
TYPE HCM
250 A max. branch circuit breaker FA, FH, FY, FI, QB, QD, QG, QJ, HD, HG, HJ, HL, JD, JG, JJ, JL
QB, QD QG, QJ FA, FH FI, FY HD, HG HJ, HL JD, JG JJ, JL Total Breaker Mounting Space Each Side
12
S N
TYPE HCP-SUh
800 A max. main circuit breaker 600 A max. branch circuit breaker DG, DJ, DL, FY, FA, FH, FI, KI, LA, LH, LC, LX, LI, LXI, LE, MG, MJ, PG, PJ, PL, PGC, PJC, PLCj, QB, QD, QG, QJ, HD, HG, HJ, HL, JD, JG, JJ, JL
FY, FA, FH, FI HD, HG, HJ, HL QB, QD, QG, QJ JD, JG, JJ, JL, KI DG, DJ, DL, LA, LH LC, LX, LE, LXI, LI MG, MJ, PG, PJ, PL PGC, PJC, PLC
S N
j k l m
Add F for Flush or S for Surface. Add-on door kit available from Peru. Example: For HCM48TS surface trim kit, order HCM48DS door kit. For Type 1 applications, order interior, front, and box. For Type 3R/5/12 applications, order interior and box only. The front is included with the box. Remove drain screws for Type 3R rating. Bottom feed standard, for top feed main circuit breaker specify at time of order. Hinged trim with door. For main lugs panel, order sub-feed lug kit and back-feed as main lugs. For main circuit breaker panel, order plug-on I-LINE type PG, PJ, PL, MG or MJ circuit breakers from 9-28 through 9-30 and backfeed as the main breaker (order solid neutral from 9-22). Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided and the panelboard is not used as a lighting and appliance branch circuit panelboard. PG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. C suffix denotes a 100% rating. Circuit breaker interrupt ratings, starting on page 7-2. I-Line Surgelogic TVSS not available. DB9 box is 9.5 inches deep.
PE1A
Discount Schedule
9-21
PANELBOARDS
Table 9.97:
(1200 A Interiors Include solid neutral, all others without solid neutral. Order solid neutral from 9-23.)
Max. No. of LC, MJ, PL, RL Circuit Breakers Complete Surface $ Price (4 Piece Trim) (Less Branch Breakers) Type 1 Front a Interior Assembly (Less Branch Circuit Breakers) 4 Piece Trim Without Door b Catalog Number $ Price Box c Trim With Door Catalog Number Catalog Number Box Height (In.)
9
PANELBOARDS
Catalog Number
$ Price
$ Price
$ Price
S N
HCP Main Lugs Only3-pole Suitable for use as service equipment when provided with a main circuit breaker. d 400 2751. HCP14504 1902. 600 3513. HCP14506 2664. 27 1PL HCW50T( ) 606. HCW50T( )D 743. HC4250DB 243. 800 4521. HCP14508 3672. 1200 6365. HCP145012N 5516. 400 3212. HCP23594 2298. 600 3860. HCP23596 2946. 45 2PL HCW59T( ) 671. HCW59T( )D 827. HC4259DB 243. 800 4874. HCP23598 3960. 1200 7133. HCP235912N 6219. 400 3795. HCP32684 2706. 600 4476. HCP32686 3387. 63 3PL HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 800 5309. HCP32688 4220. 1200 7763. HCP326812N 6674. 400 4716. HCP50864 3372. 600 5208. HCP50866 3864. 99 5PL HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 800 6194. HCP50868 4850. 1200 8529. HCP508612N 7185. HCP Main Circuit BreakereIncludes 3-pole Vertically mounted main circuit breakerSuitable for use as service equipment. 600 12179. HCP18686M 11090. 36 2LC HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 800 15399. HCP18688M 14310. 600 12987. HCP36866M 11643. 72 4LC HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 800 16296. HCP36868M 14952. HCR-U Universal Main Lugs or Main Circuit Breakere3-pole Suitable for use as service equipment when provided with a main circuit breaker. For MAIN LUGS panel, order sub-feed lug kit catalog number S33930 and back feed as main lugs. For MAIN CIRCUIT BREAKER panel, order plug-on I-LINE type PG, PJ, PL, RGC, RJC or RLCf circuit breakers from pages 9-27 through 9-29, and back feed as the main circuit breaker. (Order solid neutral separately) 108g a b c d e f g h 1200 6PL or 3RLC 12557. HCR548612U 11213. HCR86T( )h 1101. HCR86T( )D 1344. HC4486DB 243.
50
59
68
86
68 86
86
Add F for Flush or S for Surface. Add-on door kit available. Example: For HCW50TS trim kit, order HCW50D door kit. See 9-23 for 42 in. wide weatherproof enclosures. Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided and the panelboard is not used as a lighting and appliance branch circuit panelboard. Circuit breaker interrupt ratings, starting on page 7-2. When RL main circuit breakers with equipment ground fault are applied on a 34W system, order solid neutral catalog number HCR12SNCT. The HCR12SNCT includes a neutral current transformer. 15 in. of mounting space is taken up by the back fed main lug kit or RG, RJ, RL main circuit breaker, leaving 93 in. of branch circuit breaker mounting space. Add-on door kit available. Example: For HCR86TS trim kit, order HCW86D door kit.
FA, FH, FY HD, HG HJ, HL QB, QD QG, QJ FI, KI, JD JG, JJ, JL DG, DJ, DL, LA, LH LC, LI, LX LXI, LE MG, MJ
QB, QD QG, QJ FA, FH, FY HD, HG HJ, HL FI, KI, JD JG, JJ, JL
Table 9.98:
Type of Circuit Breaker FY FA, FH FA, FH FA, FH, FI, SL-100 HD, HG HD, HG, HJ, HL QB, QD, QG, QJ
S/N
2, 3
Table 9.99:
Table 9.100:
Merchandised copper interiors are not available in all ampacities. Example: Application calls for a HCN 225A copper bus interior, order a HCN 600A interior See table 9.100
9-22
PE1A
Discount Schedule
Accessories
Class 690, 2110 / Refer to Catalog 2110CT9701 Table 9.101: I-Line Merchandised Panelboard Accessories
Description Blank Fillers1.5 in. (3 per pkg.) Blank Fillers4.5 in. (5 per pkg.) Solid Neutral Assemblies 225 A 400 A 600 A Catalog No. HNM1BL HNM4BL HC2SN HC4SNa, HCW4SNb HC6SNa, HCW6SNb HC8SNa, HCW8SNb HCPSU8SNc HCPSU8SNCTc HCW12SNb HCWM12SNd HCR12SNCTd PK27GTA PK32DGTA HLW1BL HLW4BL $ Price 14.30 25.20 252.00 333.00 464.00 717.00 1151.00 1269.00 843.00 1151.00 1269.00 33.80 104.00 14.30 25.20
Blank Fillers
Solid Neutral
800 A 1200 A 1200 A, for use with HCR-U universal panel only 1200 A, Including neutral CT for 34W systems Equipment Ground Bar KitsHCN HCM, HCP HCR-U , Blank Extensions(For replacement purposes only in 1.5 in. (3 per pkg.) Type HCP, HCR-U panelboards) 4.5 in. (5 per pkg.) a b c d
Blank Extensions
Used on Type HCN, HCM. Used on 400 A, 600 A, 800 A, 1200 A HCP (main lugs), and 600 A, 800 A (main circuit breaker). Used on Type HCP-SU. Used on Type HCR-U.
Table 9.102:
For use with MLO panel, order VCEL lugs seperately. Not for use with P- or R-frame circuit breakers or sub-feed kits S33930 or S33931.
Table 9.103:
Table 9.104:
Box Extensions
Interior Type HCP-SU HCN HCM HCP HCR-U HCR-U Extension 9 in. 9 in. 9 in. 12 in. 6 in. 12 in. $ Price 552. 552. 552. 641. 552. 641.
Box Extension
Table 9.105:
Ampere Rating 100 250 250 400 800 1200 1200 a b Height
IN (mm) 4.5 114 SL100 4.5 114 SL250 4.5 114 SL250 6 152 SL400b 9 9 15 229 SL800
Plug-on in same manner as a branch circuit breaker SL400 cannot be used in HCM panelboards due to inadequate wire bending space.
Table 9.106:
Catalog No. (Prefix) SL100 SL250 SL400 SL800 S33931 S33930 a
Unless otherwise specified, wire sizes apply to both aluminum and copper conductors.
For Surgelogic I-Line plug-on TVSS unit pricing and information, refer to Section 6 pages 3-4. For Field Installable I-Line Door Kits see the Supplemental & Obsolescence Digest section 4.
2009 Schneider Electric All Rights Reserved
PE1A
Discount Schedule
9-23
PANELBOARDS
Table 9.107:
QO Distribution Panel240 Vac Max. Only Mounts in Type HCN, HCM, HCP, HCP-SU, or HCR-U I-Line panelboards, 30 A max. branch circuit breaker. Order QO plug-on circuit breakers from page 9-33.
Mounting Height IN 4.5 4.5 4.5 4.5 mm 114 114 114 114 2-pole Catalog Number HQO206AB HQO206BC HQO206AC 3-pole Catalog Number HQO306 $ Price a 369. 369. 369. 369.
Table 9.111:
Ampere Rating
9
PANELBOARDS
Hold 2-pole, 240 Vac a 15 20 275 25 30 35 40 400 45 50 60 800 70 80 90 900 100 3-pole, 240 Vac 15 20 275 25 30 35 40 400 45 50 60 800 70 80 90 900 100 a
600
850
1450 1700
600
572.
AL50FA #14#4 AWG Cu or #12#4 AWG Al AL100FA #14#1/0 AWG Cu or #12#1/0 AWG Al AL100FA #14#1/0 AWG Cu or #12#1/0 AWG Al AL100FA #14#1/0 AWG Cu
850
1450 1700
Table 9.108:
Example: FJA, 20 A 1-pole, 277 Vac and 70 A 2- and 3-pole QB 240 Vac. Use phase option number for HD, HG, HJ, HL, JD, JG, JJ, JL, MG and MJ.
Phase Connection A B C AB AC BA BC CA CB ABC CBA 1-pole FJA140201 FJA140203 FJA140205 2-pole QBA220701 QBA220702 QBA220703 QBA220704 QBA220705 QBA220706 3-pole QBA32070 QBA320706
1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix.
Table 9.112:
The absence of a phase option number after a 3-pole catalog number will result in an ABC phase connection.
Table 9.109:
Phase Option Letter A B C AB AC BC ABC CBA
Example: FA, 30 A, 480 Vac. Use phase option letters for FH, FI, KI, LA, LH, LC, and LI.
1-pole FA14035A FA14035B FA14035C 2-pole FA24030AB FA24030AC FA24030BC 3-pole FA34030 FA34030CBA
Table 9.110:
240 V 277 V 480 V 600 V
AC Magnetic Standard Interrupting Extra High Interrupting Terminal Wire Range Ampere Trip Settings Rating Catalog Catalog FY/FA FJ/FC Lugs Hold Trip $ Price Number $ Price Number Lugs 1-pole, 277 Vac, 125 Vdc a 15 FY14015( )b FJA14015( ) AL50FA AL30FD #14-#4 #12#6 20 FY14020( )b FJA14020( ) 275 600 149. 651. AWG Cu, or AWG Al, or 25 FY14025( )b FJA14025( ) #12-#4 #14#6 30 FY14030( )b FJA14030( ) AWG Al AWG Cu 35 FA14035( )c FJA14035( ) 40 FA14040( )c FJA14040( ) 400 850 302. 651. 45 FA14045( )c FJA14045( ) AL100FA AL100FD 50 FA14050( )c FJA14050( ) #14#1/0 #12#2/0 AWG Al 60 FA14060( )c FJA14060( ) 651. AWG Cu or or 800 1450 FA14070( )c 302. FJA14070( ) 70 720. #12#1/0 #14#2/0 AWG Al AWG Cu 80 FA14080( )c 90 FA14090( )c 900 1700 302. 100 FA14100( )c 2-pole, 480 Vac, 250 Vdc abc AL50FA CU30FA4 15 FA24015( ) 20 FA24020( ) #14#4 one #14 651. 275 600 25 FA24025( ) AWG Cu or #10 AWG #12#4 Cu only 30 FA24030( ) AWG Al 35 FA24035( ) 40 FA24040( ) 400 850 651. 45 FA24045( ) AL100FA AL100FA4 50 FA24050( ) #14#1/0 one #14#3 AWG Cu 60 FA24060( ) 651. AWG Cu or or 800 1450 FA24070( ) 70 #12#1/0 one #12#1 833. AWG Al AWG Al 80 FA24080( ) 90 FA24090( ) 900 1700 833. 100 FA24100( ) 3-pole, 480 Vac, 250 Vdc a 15 FA34015 AL50FA CU30FA4 20 FA34020 #14#4 one #14 275 600 833. 25 FA34025 AWG Cu or #10 AWG #12#4 Cu only 30 FA34030 AWG Al 35 FA34035 40 FA34040 400 850 833. 45 FA34045 AL100FA AL100FA4 50 FA34050 #14#1/0 one #14#3 AWG Cu 60 FA34060 833. AWG Cu or or 800 1450 70 FA34070 #12#1/0 one #12#1 996. AWG Al AWG Al 80 FA34080 90 FA34090 900 1700 996. 100 FA34100 a b c 1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. Rated 277 Vac 15 and 20 ampere FY circuit breakers are rated for switching duty (SWD). 15, 20, 25 and 30 ampere FA I-LINE circuit breakers are also available (no SWD rating). Rated 277 Vac, 125 Vdc, except FY circuit breakers, which have no dc rating. 1530 ampere circuit breakers suitable for use with 60oC or 75oC conductors. 35100 ampere circuit breakers are suitable for use with 75oC conductors. 2009 Schneider Electric All Rights Reserved
9-24
DE2
Discount Schedule
Circuit Breakers
www.schneider-electric.us
Table 9.113:
Ampere Rating
AC Magnetic Trip Settings Hold Trip 1-pole, 277 Vac, 125 Vdc a 15 20 275 600 25 30 35 40 400 850 45 50 60 70 800 1450 80 90 900 1700 100 2-pole, 600 Vac, 250 Vdc a 15 20 275 600 25 30 35 40 400 850 45 50 60 70 800 1450 80 90 900 1700 100 3-pole, 600 Vac, 250 Vdc 15 20 275 600 25 30 35 40 400 850 45 50 60 70 800 1450 80 90 900 1700 100 a
507.
) ) ) ) ) ) ) )
971.
1446.
1- and 2-pole circuit breaker catalog numbers are completed by adding the required connection letters as a suffix, see 9-24.
Table 9.114:
QB/QD/QG/QJ Mounting Height: 2-pole3 in (76 mm) 3-pole4.5 in (114 mm)
AC Magnetic Ampere Trip Settings Rating Hold Trip 2-pole, 240 Vac b 70 80 1000 1800 90 100 110 125 150 1200 2400 175 200 225 3-pole, 240 Vac c 70 80 1000 1800 90 100 110 125 150 1200 2400 175 200 225 a b c
600.
1202.
1593.
1992.
600.
1202.
1593.
1992.
1913.
2069.
2835.
3245.
1913.
2069.
2835.
3245.
Replacement lugs are not available on QB, QD, QG, or QJ circuit breakers. Lugs for QB, QD, QG or QJ circuit breakers accept one #4 AWG300 kcmil. No accessories are available for PowerPact Q Frame breakers. 2-pole QB, QD, QG and QJ circuit breakers are completed by adding the required phasing numbers as indicated in the parentheses, see 9-24. 3-pole QB, QD, QG and QJ circuit breakers for ABC phasing are complete without additional phasing number. For CBA phasing, complete the catalog number by inserting the number 6 in the parentheses.
Table 9.115:
240 V 480 V 600 V a
F-Frame accessories. . . . . . . . . . . . . . Supplemental & Obsolescence Digest F-Frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-49 F-Frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-54 Q-Frame dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-54 2009 Schneider Electric All Rights Reserved Discount Schedule
DE2
9-25
780.
1214.
PANELBOARDS
Circuit Breakers
H- and J-frame
Table 9.116:
Ampere Rating
9
PANELBOARDS HD/HG 2-pole 3 in. (76 mm) Mounting Height H-frame 3-pole 4.5 in. (114 mm) Mounting Height J-frame 3-pole 4.5 in (114 mm) Mounting Height
H-frame 150 A Standard Rated Thermal Magnetic (600 Vac) with Factory Sealed Trip Units
D Interrupting Catalog No. HDA26015( ) HDA26020( ) HDA26025( ) HDA26030( ) HDA26035( ) HDA26040( ) HDA26045( ) HDA26050( ) HDA26060( ) HDA26070( ) HDA26080( ) HDA26090( ) HDA26100( ) HDA26110( ) HDA26125( ) HDA26150( ) HDA36015 HDA36020 HDA36025 HDA36030 HDA36035 HDA36040 HDA36045 HDA36050 HDA36060 HDA36070 HDA36080 HDA36090 HDA36100 HDA36110 HDA36125 HDA36150 $ Price G Interrupting Catalog No. HGA26015( ) HGA26020( ) HGA26025( ) HGA26030( ) HGA26035( ) HGA26040( ) HGA26045( ) HGA26050( ) HGA26060( ) HGA26070( ) HGA26080( ) HGA26090( ) HGA26100( ) HGA26110( ) HGA26125( ) HGA26150( ) HGA36015 HGA36020 HGA36025 HGA36030 HGA36035 HGA36040 HGA36045 HGA36050 HGA36060 HGA36070 HGA36080 HGA36090 HGA36100 HGA36110 HGA36125 HGA36150 $ Price J Interrupting a Catalog No. HJA26015( ) HJA26020( ) HJA26025( ) HJA26030( ) HJA26035( ) HJA26040( ) HJA26045( ) HJA26050( ) HJA26060( ) HJA26070( ) HJA26080( ) HJA26090( ) HJA26100( ) HJA26110( ) HJA26125( ) HJA26150( ) HJA36015 HJA36020 HJA36025 HJA36030 HJA36035 HJA36040 HJA36045 HJA36050 HJA36060 HJA36070 HJA36080 HJA36090 HJA36100 HJA36110 HJA36125 HJA36150 $ Price L Interrupting a Catalog No. HLA26015( ) HLA26020( ) HLA26025( ) HLA26030( ) HLA26035( ) HLA26040( ) HLA26045( ) HLA26050( ) HLA26060( ) HLA26070( ) HLA26080( ) HLA26090( ) HLA26100( ) HLA26110( ) HLA26125( ) HLA26150( ) HLA36015 HLA36020 HLA36025 HLA36030 HLA36035 HLA36040 HLA36045 HLA36050 HLA36060 HLA36070 HLA36080 HLA36090 HLA36100 HLA36110 HLA36125 HLA36150 $ Price Terminal Wire Range
AC Magnetic Trip Setting Hold Trip 2-pole, 600 Vac 50/60 Hz 15 20 350 750 25 30 35 40 400 850 45 50 60 70 800 1450 80 90 100 110 900 1700 125 150 3-pole, 600 Vac 50/60 Hz 15 20 350 750 25 30 35 40 400 850 45 50 60 70 800 1450 80 90 100 110 900 1700 125 150 a 2 pole in 3p module
899.
1338.
1589.
2483.
1124.
1575.
1988.
2993.
Table 9.117:
Ampere Rating
J-frame 250 A Standard Rated Thermal Magnetic (600 Vac) with Factory Sealed Trip Units
D Interrupting b Catalog No. JDA26150( ) JDA26175( ) JDA26200( ) JDA26225( ) JDA26250( ) JDA36150 JDA36175 JDA36200 JDA36225 JDA36250 2867. 3936. 2283. 2283. 3138. $ Price G Interrupting b Catalog No. JGA26150( ) JGA26175( ) JGA26200( ) JGA26225( ) JGA26250( ) JGA36150 JGA36175 JGA36200 JGA36225 JGA36250 3968. 5252. 3372. 3372. 4463. $ Price J Interrupting b Catalog No. JJA26150( ) JJA26175( ) JJA26200( ) JJA26225( ) JJA26250( ) JJA36150 JJA36175 JJA36200 JJA36225 JJA36250 5705. 7599. 4904. 4904. 6536. $ Price L Interrupting b Catalog No. JLA26150( ) JLA26175( ) JLA26200( ) JLA26225( ) JLA26250( ) JLA36150 JLA36175 JLA36200 JLA36225 JLA36250 7299. 9173. 5985. 5985. 7338. $ Price Terminal Wire Range
AC Magnetic Trip Setting Low High 2-pole, 600 Vac 50/60 Hz 150 750 1500 175 875 1750 200 1000 2000 225 1125 2250 250 1250 2500 3-pole, 600 Vac 50/60 Hz 150 750 1500 175 200 225 250 b 875 1000 1125 1250 1750 2000 2250 2500
AL175JD #1/04/0 AWG Al or Cu AL250JD #3/0350 kcmil Al or Cu AL175JD #1/04/0 AWG Al or Cu AL250JD #3/0350 kcmil Al or Cu
2 pole in 3p module
Table 9.118:
Ampere Rating
Catalog Number
G Interrupting 150 HGA26000S15( )b 1416. 1919. HGA36000S15 JGA36000S17 JGA36000S25 HLA36000S15 JLA36000S17 JLA36000S25 1889. 2400. 65 65 35 35 18 18
175 JGA26000S17( ) 250 JGA26000S25( ) L Interrupting 150 175 250 a b HLA26000S15( ) HLA26000S17( ) JLA26000S25( )
1670. 2079.
2087. 2600.
125 125
100 100
50 50
The withstand rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. 2-pole device with 3 in. (76 mm) mounting height, all other 2-pole circuit breakers use 3-pole module 4.5 in. (114 mm) mounting height.
Table 9.119:
Phase Option Number 1 2 3 4 5 6 Standard 6
Table 9.120:
240 V 480 V 600 V D 25 18 14
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-36 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-39 2009 Schneider Electric All Rights Reserved
9-26
DE2
Circuit Breakers
www.schneider-electric.us
Table 9.121:
Ampere Rating
125 150 175 200 225 250 200 225 250 3-pole, 600 Vac, 250 Vdc 70 80 90 100 110 125 150 175 200 225 250 200 225 250 a
2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See 9-24.
Table 9.122:
Table 9.123:
Voltage 240 Vac 480 Vac 600 Vac
Table 9.124:
PowerPact R-frame 1200 A (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit
$ Price Sensor Rating 3.0 5.0 3.0A 5.0A 6.0A 5.0P 6.0P 5.0H 6.0H 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A Cat. No. bc R( )A36100CU31A R( )A36120CU31A R( )A36100CU33A R( )A36120CU33A R( )A36100CU41A R( )A36120CU41A R( )A36100CU43A R( )A36120CU43A R( )A36100CU44A R( )A36120CU44A R( )A36100CU63AE1 R( )A36120CU63AE1 R( )A36100CU64AE1 R( )A36120CU64AE1 R( )A36100CU73AE1 R( )A36120CU73AE1 R( )A36100CU74AE1 R( )A36120CU74AE1 G Interruptingbc J Interruptingbc K Interruptingbc L Interruptingbc 100% Rated 33945. 34401. 35141. 36581. 38378. 40826. 41867. 44754. 45795. 100% Rated 36111. 36599. 37383. 38916. 40829. 43431. 44540. 47610. 48719. 100% Rated 36111. 36599. 37383. 38916. 40829. 43431. 44540. 47610. 48719. 100% Rated 38418. 38934. 39770. 41400. AL1200R53K 43434. (4) 3/0-600 kcmil Al or Cu 46205. 47382. 50649. 51827. Terminal Wire Range
Electronic Trip Unit Type Micrologic Interchangeable Standard Trip Unit Function Code LI LSI LI Micrologic Interchangeable Ammeter Trip Unit LSI LSIG Micrologic Interchangeable Power Trip Unit Micrologic Interchangeable Harmonic Trip Unit a b c LSI LSIG LSI LSIG
For 2P and 4P information see Catalog 0612CT0101. To complete the catalog number, replace the blank ( ) with the appropriate interrupt rating (G, J, K or L). See page 9-123 for interrupt ratings table.
DE2
Discount Schedule
9-27
PANELBOARDS
Circuit Breakers
Table 9.125:
Ampere Rating
L-frame400 A, I-Line LA/LH MC High Magnetic Withstand Circuit Breaker For Mission Critical Loads
Standard Interrupting Catalog Number $ Price High Interrupting Catalog Number LH34200MC LH34225MC LH34250MC LH34400MC $ Price Terminal Wire Range
9
PANELBOARDS LA/LH 2- and 3-pole 6 in (152 mm) Mounting Height LI 2- and 3-pole 7.5 in (190 mm) Mounting Height LC 2- and 3-pole 7.5 in (190 mm) Mounting Height
3-pole, 480 Vac, LA/LH MC Circuit Breaker 200 4000 LA34200MC 225 4500 LA34225MC 250 5000 LA34250MC 400 8000 LA34400MC
AL250LA one #4 AWG350 kcmil AL or Cu AL400LA one #1 AWG600 kcmil or two #1 AWG250 kcmil AL or Cu
Table 9.126:
Ampere Rating
2-pole, 600 Vac, 250 Vdc a 125 625 150 750 175 875 200 1000 225 1125 250 1250 300 1500 350 1750 400 2000 3-pole, 600 Vac, 250 Vdc 125 625 150 750 175 875 200 1000 225 1125 250 1250 300 1500 350 1750 400 2000
LA26400( ) LA36125 LA36150 LA36175 LA36200 LA36225 LA36250 LA36300 LA36350 LA36400
LH26400( ) LH36125 LH36150 LH36175 LH36200 LH36225 LH36250 LH36300 LH36350 LH36400
Table 9.127:
Ampere Rating
2-pole, 600 Vac a 300 1500 350 400 450 500 600 3-pole, 600 Vac 300 350 400 450 500 600 a b 1750 2000 2250 2500 3000 1500 1750 2000 2250 2500 3000 3200
8312.
4200
8691.
3200
9234.
4200
9657.
2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See 9-24. Type LC and LI circuit breakers are NOT recommended for use on single-motor branch circuits.
Accessories . . . . . . . . . . . . . . . . . . . . Supplemental & Obsolescence Digest Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-51 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-54
Table 9.128:
240 V 480 V 600 V
9-28
DE2
Discount Schedule
Circuit Breakers
www.schneider-electric.us
Table 9.129:
Electronic Trip Unit Type
D-Frame (600 A 480 Vac) 3P 50/60 Hz Circuit Breaker with Electronic Trip Units
Trip Unit Continuous Currentb 150 A 250 A 400 A 600 A 150 A 250 A 400 A 600 A 150 A 250 A 400 A 600 A G interrupting Catalog No. DGA34150E20 DGA34250E20 DGA34400E20 DGA34600E20 DGA34150E53 DGA34250E53 DGA34400E53 DGA34600E53 DGA34150E58 DGA34250E58 DGA34400E58 DGA34600E58 $ Price J Interrupting Catalog No. $ Price L Interrupting Catalog No. $ Price 10468. Terminal Wire Range (1) 2600 Cu or (1) 2500 Al
Trip Function
L interrupting rating is not available in M-frame. 600 V interrupt ratings not available for D-frame.
13702. (2) 2/0350 Cu or (2) 2/0500 Al 11587. (1) 2600 Cu or (1) 2500 Al
14821. (2) 2/0350 Cu or (2) 2/0500 Al 13048. (1) 2600 Cu or (1) 2500 Al
Ammeter a b
LSI
STR53-UPFIa
F = Fault Indicator, I = Ammeter. D-frame circuit breakers 400 A and below are 100% rated. 600 A is standard (80%) rated only.
Ampere Rating 300 350 400 450 500 600 700 800 300 350 400 450 500 600 700 800
Adjustable Instantaneous Trip Range b Low 600 700 800 900 1000 1200 1400 1600 600 700 800 900 1000 1200 1400 1600 High 3000 3500 4000 4500 5000 6000 7000 8000 3000 3500 4000 4500 5000 6000 7000 8000
G Interrupting Catalog Number c MGA26300( ) MGA26350( ) MGA26400( ) MGA26450( ) MGA26500( ) MGA26600( ) MGA26700( ) MGA26800( ) MGA36300 MGA36350 MGA36400 MGA36450 MGA36500 MGA36600 MGA36700 MGA36800 $ Price
J Interrupting Catalog Number c MJA26300( ) MJA26350( ) MJA26400( ) MJA26450( ) MJA26500( ) MJA26600( ) MJA26700( ) MJA26800( ) MJA36300 MJA36350 MJA36400 MJA36450 MJA36500 MJA36600 MJA36700 MJA36800 $ Price
6633.
8253.
8370.
10104.
8168.
9929.
10608.
12630.
a b c
The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the long-time trip point setting. It is considered an electronic equivalent of a thermal-magnet circuit breaker. UL magnetic trip setting tolerances are 10% from the nominal values shown. Fill in parentheses with the following phase connection options: (2) for AC and (5) for CA.
L-Frame accessories . . . . . . . . . . . . . Supplemental & Obsolescence Digest L-Frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .starting on page 7-54 L-Frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-51 M & P-Frame accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-36 M & P-Frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-55 M & P -Frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7-39
Ampere Rating
LA/LH MC Circuit Breaker, 3P, 480 Vac 200 A 3400 A 4000 A 225 A 3825 A 4500 A 250 A 4250 A 5000 A 400 A 6000 A 7200 A
(1) 250350 kcmil Al (1) 3/0 AWG350 kcmil Cu (1) 1 AWG600 kcmil Al or (2) 1 AWG250 kcmil Al
DE2
Discount Schedule
9-29
Table 9.130:
PowerPact M-frame: with ET1.0 Factory sealed trip unit (not field adjustable)800 A a
PANELBOARDS
LS
STR23SP
DJA34150E20 5631. DJA34250E20 DJA34400E20 8865. DJA34600E20 DJA34150E53 6750. DJA34250E53 DJA34400E53 9984. DJA34600E53 DJA34150E58 8211. DJA34250E58 DJA34400E58 11445. DJA34600E58
DLA34150E20 9028. DLA34250E20 DLA34400E20 12262. DLA34600E20 DLA34150E53 10147. DLA34250E53 DLA34400E53 13381. DLA34600E53 DLA34150E58 11608. DLA34250E58 DLA34400E58 14842. DLA34600E58
Circuit Breakers
Table 9.132:
Ampere Rating 600 800 1000 1200 a b
9
PANELBOARDS
The withstand rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker with an equal ampere rating. Fill in parentheses with the following phase connection options: (2) for AC or (5) for CA.
Table 9.133:
PowerPact P-frame 1200 A (600 Vac, 50/60 Hz) 3P a Circuit Breaker with Electronic Trip Unit
$ Price Sensor Rating Code 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A P( )A36060 P( )A36080 P( )A36100 P( )A36120 P( )A36025(C)U31A P( )A36040(C)U31A P( )A36060(C)U31A P( )A36080(C)U31A P( )A36100U31A P( )A36120U31A P( )A36025(C)U33A P( )A36040(C)U33A P( )A36060(C)U33A P( )A36080(C)U33A P( )A36100U33A P( )A36120U33A P( )A36025(C)U41A P( )A36040(C)U41A P( )A36060(C)U41A P( )A36080(C)U41A P( )A36100U41A P( )A36120U41A P( )A36025(C)U43A P( )A36040(C)U43A P( )A36060(C)U43A P( )A36080(C)U43A P( )A36100U43A P( )A36120U43A P( )A36025(C)U44A P( )A36040(C)U44A P( )A36060(C)U44A P( )A36080(C)U44A P( )A36100U44A P( )A36120U44A P( )A36025(C)U63AE1 P( )A36040(C)U63AE1 P( )A36060(C)U63AE1 P( )A36080(C)U63AE1 P( )A36100U63AE1 P( )A36120U63AE1 P( )A36025(C)U64AE1 P( )A36040(C)U64AE1 P( )A36060(C)U64AE1 P( )A36080(C)U64AE1 P( )A36100U64AE1 P( )A36120U64AE1 P( )A36025(C)U73AE1 P( )A36040(C)U73AE1 P( )A36060(C)U73AE1 P( )A36080(C)U73AE1 P( )A36100U73AE1 P( )A36120U73AE1 P( )A36025(C)U74AE1 P( )A36040(C)U74AE1 P( )A36060(C)U74AE1 P( )A36080(C)U74AE1 P( )A36100U74AE1 P( )A36120U74AE1 Cat. No.bc G Interrupting b 80% Rated 14603. 20003. 21207. 100% Rated c J Interrupting b 80% Rated 15480. 21207. 100% Rated c K Interrupting b 80% Rated 15480. 22410. 100% Rated c L Interrupting bd 80% Rated 16359. 100% Rated c Terminal Wire Range
Basic Electronic Fixed long-time, Trip Unit Adjustable ET1.0I (Not Interchangeable) Instantaneous
15390.
22479.
16268.
23897.
16268.
23897.
17147.
3.0
25314. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 25668. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 26204. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 27770. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 29721. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 32379. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 33510. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 36645 (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu 37776. (3) 3/0 AWG500 kcmil Al or Cu (4) 3/0 AWG500 kcmil Al or Cu
20790.
21995.
21995.
23198.
15729.
22794.
16608.
24231.
16608.
24231.
17487.
5.0
21131.
22334.
22334.
23538.
16242.
23270.
17121.
24737.
17121.
24737.
17999.
LI
3.0A
21642.
22845.
22845.
24051.
17739.
24659.
18618.
26214.
18618.
26214.
19497.
LSI
5.0A
23141.
24345.
24345.
25548.
19607.
26393.
20486.
28058.
20486.
28058.
21365.
LSIG
6.0A
25008.
26211.
26211.
27416.
22151.
28754.
23030.
30566.
23030.
30566
23909.
5.0P
27552.
28757.
28757.
29960.
23234.
29757.
24111.
31634.
24111.
31634.
24990.
6.0P
28634.
29838.
29838.
31041.
26234.
32541.
27113.
34593.
27113.
34593.
27992.
5.0H
31634.
32837.
32837.
34043.
27315.
33545.
28194.
35661.
28194.
35661.
29073.
6.0H
32717.
33921.
33921.
35124.
a b c d
For 2P and 4P information see Catalog 0612CT0101. To complete the catalog number, replace the ( ) with the appropriate interrupt rating (G, J, K or L). For 100% rated circuit breakers add a C in the 9th character place. For example, the catalog number for a 100% standard-type trip unit with LI trip functions at 250A would be PGA36025CU31A. The L interrupt rating is supplied in 480 V only. Change the 5th character (voltage rating) from a 6 (600V) to a 4 (480V); for example, PLA34025U31A. Alternate Rating Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-44 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-55 Trip Unit Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-43 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-39
9-30
DE2
Discount Schedule
Table 9.134:
When required, add the $ Price of a solid neutral from Table 9.136.
Table 9.135:
Panel Type
No. Poles 2 3 2 3 2 3
Panel Type
Micrologic 80% Micrologic 100% 14778. 17456. 14778. 19346. 15830. 16830. 21090. 16542. 18510. 24250. 17456. 23416. 18312. 20280. 24540. 20144. 22300. 28220. 1200 A bcd
MJ
PL a
PG b
PJ b
PL b
Panel Type
PG
PJ
PL
RGC
RJC
RLC
Micrologic 80% 22380. 24980. 27980. 28710. 31310. 35570. 22380. 24980. 27980. 28710. 31310. 35570.
Micrologic 100% 24618. 24478. 32178. 31582. 34442. 40906. 24618. 24478. 32178. 31582. 34442. 40906.
When required, add the $ Price of a solid neutral from Table 9.136. Std. construction back-fed main. PG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. The C suffix denotes a 100% rating. For 1200 A frame thermal magnetic circut breaker with 600 kcmil lugs, select a R-Frame Thermal Magnetic circuit breaker in the Product Selector.
Table 9.136:
Solid Neutral
Table 9.138:
Table 9.137:
LS LSI LSIG
Note: Micrologic circuit breakers come with a standard LI trip unit. Use the above $ Price adder for increase in trip functionality. Note: Refer to page 7-42 for trip unit descriptions.
Table 9.139:
Panel Type
a Type 1 Enclosure H Inches 91 91 91 91 86 68 86 86 mm 2311 2311 2311 2311 2184 1727 2184 2184 Inches 32 32 32 32 44 42 42 26 W mm 813 813 813 813 1118 1067 1067 660 Inches 8.25 9.50 8.25 9.50 9.50 9.50 9.50 9.5 D mm 210 241 210 241 241 241 241 241
Neutral Terminals Quantity & Size Main (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil Branch
HCM
600 A 600 A (MG, MJ) 800 A 800 A (MG, MJ) 1200A 600A
(35) 350 kcmil, (9)#14-1/0, (17)#14-#4 (8) 600 kcmil, (15) 350 kcmil (9) #14-1/0, (17)#14-#4 (35) 350 kcmil, (9)#14-1/0, (17)#14-#4 (35) 350 kcmil, (9)#14-1/0, (17)#14-#4 (8) 750 kcmil, (21) 350 kcmil, (9) #14-1/0, (17) #14-#4
HCR-Ub
Available in Type 1 enclosure only; for pricing see 9-33. 6 in. enclosure extension is required for HCRU I-Line panelboard. 9 in. enclosure extension is required for HCP-SU I-Line panelboard.
PE1
Discount Schedule
9-31
PANELBOARDS
Branch Circuit Breakers (See pages 7-2 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.)
Circuit Breaker 3-pole a 240 V 480 Vac 250 Vdc 882. b 1142. b 2080. 2470. 20360. 24526. 5687. 8954. 9118. 12385. 10573. 13839. 15400. 20570. 22220. 29850. 16940. 22620. 24440. 600 V 1006. 1218. 1442. 1940. 4254. 1350. 1570. 2710. 1710. 2198. 3310. 2380. 2700. 4500. 3910. 4054. 5530. 2820. 3800. 3990. 4180. 6110. 6500. 7320. 8900. 7972. 9268. 4916. 5312. 10156. 10422. 11622. 15834. 8152. 10600. 10126. 13306. 19966. 21960. 8900. 13310. 14730. 21240. 10400. 15570. 17220. 24850. 9790. 14642. 16200. 11960. 17900. 19800. 24460. 26710. 32580. Space Only 98. 98. 98. 98. 98. 98. H 4.5 4.5 4.5 3 4.5 4.5 240 Vac 520. 632. 1050. 1250. 1250. 1450. 560. 1300. b 2800. 3000. 3600. 4600. 3900. 4000. 4300. 4300. 4550. 2-pole a 480 Vac 250 Vdc 600 Vac 708. 956. 1660. 1980. 5434. 6672. 5434. 6672. 16290. 22046. 4550. 7163. 7295. 9908. 8458. 11071. 12320. 16450. 17780. 23880. 13550. 18100. 19560. 786. 964. 1218. 1620. 3466. 1150. 1370. 2370. 1352. 1508. 3110. 2002. 2364. 3980. 3250. 3402. 4600. 2600. 3430. 2790. 3620. 5770. 6450. 6000. 6800. 6216. 7262. 3980. 4500. 8634. 8920. 9878. 14248. 6322. 8180. 8536. 10944. 17940. 19724. 7120. 10648. 12402. 16992. 9240. 12450. 13780. 19880. 7832. 11714. 13642. 9570. 14330. 15840. 19580. 21380. 26080. Space Only 82. 98. 98. b 98. 98. H 120 V 354. 277 V 384. 664. 832. 1-pole a 277 Vac 125 Vdc 270. c 384. c 518. 650. Space Only 72. 72. 72. 72. 72. 72. H 1.5 1.5 1.5 1.5 1.5 1.5
9
PANELBOARDS
Thermal-magnetic Circuit Breakers 1560 A FA (FY-1P) 720. 70100 A FA 832. 1560 A 1100. FH 70100 A 1300. 1560 A 1300. FJ d 70100 A 1500. 20100 A FI 1560 A 70100 A HD 110150 A 1560 A 70100 A HG 110150 A 1560 A 70100 A HJ 110150 A 1560 A 70100 A HL 110150 A 70225 A QB 1696. 70225 A QD 2208. 70225 A QG 2870. 70225 A QJ 3070. 150225 A JD 250 A 150225 A JG 250 A 150225 A JJ 250 A 150225 A JL 250 A 150225 A KI 250 A 300400 A LA 300400 A LH 300400 A 5460. LC 450600 A 300400 A LI 450600 A 300600 A MG 700800 A 300600 A MJ 700800 A 600800 A PL 6001200 A PG 6001200 A PJ /PK 10001200 A PL Electronic Trip Circuit Breakers (% Rated) 60400 A DG (100%)e 600 A DG (80%)e 60400 A DJ (100%)e 600 A DJ (80%)e 60400 A DL (100%)e 600 A DL (80%)e 250400 A 450600 A PG (80%)f 700800 A 10001200 A 250400 A 450600 A PJ/PK (80%)f 700800 A 10001200 A 250400 A 450600 A PL (80%)f 700800 A 10001200 A 250400 A 450600 A PGC (100%)f 700800 A 250400 A PJC/PKC 450600 A (100%)f 700800 A 250400 A 450600 A PLC (100%) f 700800 A RGC (100%) f 10001200 A RJC (100%) f RLC (100%) f a b c d e f
3 3 3 4.5 3
98.
4.5
98.
98.
4.5
98.
4.5
98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 252. 456. 456. 662. 662. 662. 662. 662. 662. 252. 252. 252. 252. 252. 252. 662.
4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 6 7.5 7.5 9 9 9 9 9 9 6 6 6 6 6 6 9
98. 82. 82. 82. 82. 98. 98. 98. 98. b b 98. 252. 456. b b 456. 662. 662. 662. 662. 662. 252. 252. 252. 252. 252. 252. 662.
662.
662.
662.
662.
662.
662.
662.
662.
662.
662.
662.
15
662.
15
Refer to pages 7-4 through 7-8 for additional dc ratings. ac only. FA, 1P. 480Y/277 Volt rated circuit breakerDo not use on 480 Volt 33W Delta systems. Refer to Table 9.137 on page 9-31 for DG, DJ & DL Electronic trip unit price adders. Refer to Table 9.138 on page 9-31 for P and R Frame Micrologic trip unit price adders.
9-32
PE1
Discount Schedule
Class 2110 / Refer to Catalog 2110CT9701 Table 9.141: QO Plug-On Branch Circuit Breakers
$ Price Transition Charge per 6 QO one-pole spaces (H=4.5 in. per 6 one-pole spaces) $ Price for QO Branch circuit breakers 328. on page 7-10
Table 9.150:
Table 9.142:
Ampere Rating $ Price
Sub-feed/Feed-through Lugs
2 or 3-pole Branch Mounted; SL Kit used for both SFL and TFL. 225 A 368. 400 A 600. 600 A 858. 800 A 1490. 1200 A 1890.
Table 9.151:
Ampere Rating 100/125 A 250 A 400 A 600 A 800 A 1200 A a
Table 9.143:
Ground Bars
$ Price 180. 148. $ Price Addl. Neutral Assembly
Table 9.145:
Ampere Rating 225 A 400 A 600 A 600 A 800-1200 A
Compression lugs are not available on LC, LI, LE, LX, LXI, MG, MJ, PG, PJ,PL, RGC, RJC, RLC I-Line circuit breakers. Available on MA and MH circuit breakers.
Table 9.153:
Ampere Rating
Table 9.146:
Ampere Rating 100400 A 600 A 800 A 1200 A
Neutrals
Type Copper Neutral Copper Neutral Copper Neutral Copper Neutral $ Price Adder 868. 894. 1108. 1352.
Table 9.147:
Ampere Rating 225 A 400 A 600 A 800 A 1200 A 225 A 400 A 600 A 800 A 1200 A
Note: Additional factory modifications, see 9-37. a Compression lugs are not available on LC, LI, LE, LX, LXI, MG, MJ, PG, PJ,PL, RGC, RJC, RLC I-Line circuit breakers. Available on MA and MH circuit breakers.
Table 9.148:
Metal Directory Frame Frame attached to trim (not available on four piece trim)
Door-in-Door Trim Trim has piano hinge down one side. Door opens by single latch; Entire trim opens by removing screws. Hinged Door-in-Door with Outer Door Lock Added
Surgelogic TVSS Options Surge Counter Dry Contacts Remote Monitor Note: Requires HCM interior minimum.
Table 9.155:
Voltage 120/240 1P3W 208Y/120 3P4W 240/120 3P4W 480Y/277 3P4W 600Y/347 3P4W
PE1
9-33
Equipment Ground Bar Copper Ground Bar (Add to equipment ground bar $ Price)
Compression lugs are not available on LC, LI, LE, LX, LXI, MG, MJ, PG, PJ,PL, RGC, RJC, RLC I-Line circuit breakers. Available on MA and MH circuit breakers.
PANELBOARDS
Weatherproof or Dusttight Cabinets Maximum 26 in. wide box Maximum 28 in. wide box Maximum 42 in. wide box Maximum 44 in. wide box
9
PANELBOARDS
Electrical Interlock Kit 240 Vac Catalog Number a $ Price Std. 1 3 Max. 1 3
Horsepower Ratingsi 480 Vac Std. 1 3 Max. 1 3 Std. 1 3 600 Vac Max. 1 3 5 5 10 10 20 20 40 250 Vdc
2-pole, 240 Vac 30-30 4.5 30-Blank 4.5 60-60 4.5 60-Blank 4.5 100-100 6 100-Blank 6 200 9 15 400 9 600
2 1 1 1 1 1
1.5 3 7.5
3 10 15 15
3-pole, 240 Vac 30-30 4.5 QMB321TW 827. 2 HRK30 30-Blank 4.5 QMB321HWb 587. 1 60-60 4.5 QMB322TW 827. 1 QMB36R 60-Blank 4.5 QMB322HWb 587. 100-100 6 QMB323TW 1265. 1 QMB100R 100-Blank 6 QMB323HWb 879. 200 9 QMB324W 1673. 1 HRK1020 15 QMB325W 4277. 1 QMB4060R 400 9 QMB325WT3c 4143. 15 QMB326W 6249. 1 QMB4060R 600 15 QMB326WT3c 6249. 800 15 QMB327WT3c 12140. 2-pole, 600 Vac, 250 Vdcd 30-30 4.5 QMB261TW 1050. 1 QMB36R 30-Blank 4.5 QMB261HWb 702. 60-60 6 QMB262TW 1050. 1 QMB60R 60-Blank 6 QMB262HWb 738. 100-100 7.5 QMB263TW 1536. 2 HRK1020 100-Blank 7.5 QMB263HWb 1083. 1 200 9 QMB264W 1791. 1 HRK1020 400 Use 3-pole Devices For 2-pole Application 600e 3-pole, 600 Vacd 4.5 30-30 4.5 30-Blank 4.5 6 60-60 6 60-Blank 6 6 60-30 6 7.5 100-100 6 7.5 100-Blank 6 7.5 100-30 7.5 7.5 100-60 7.5 200 9 200-200 7.5 200-Blank 7.5 400f 15 400 9 400f 9 600ef 15 600 15 800g 15 a b c d e f g h i QMB361TW QMJ361T QMB361HWb QMB362TW QMJ362T QMB362HWb QMB362T21W QMB363TW QMJ363T QMB363HWb QMJ363Hb QMB363T31W QMB363T32W 1241. 1293. 861. 1241. 1293. 861. 1241. 1961. 2013. 1373. 1424. 1961. 1961. QMB36R QMB36R QMB60R QMB60R 1 ea. QMB60R and QMB36R 2 HRK1020 1 HRK1020 1 ea. HRK1020 and QMB36R 1 1 1 1
1.5 3 7.5 15
3 10 15
3 5 10 25
5 15 25 50
7.5 20 30 50
15 30 60 125
3 10 15 30
10 25 40 50
5 10 20 40
QMB364W 2306. QMJ364T 4712. QMJ364Hb 2357. QMB365W 5445. QMJ365 5561. QMB365WT6h 5276. QMB366W 6735. QMJ366 6704. QMB367W 12140.
48.90 48.90 48.90 48.90 48.90 47.70 47.70 47.70 48.90 47.70 1 ea. HRK1020 and QMB60R 48.90 1 HRK1020 47.70 1 QMB4060R 111.00 1 QMB4060R 111.00
QMB300EK(1 or 2) QMB300EK(1 or 2) QMB610EK(1 or 2) QMB610EK(1 or 2) QMB610EK(1 or 2) QMB610EK(1 or 2) QMB610EK(1 or 2) QMB610EK(1 or 2) QMB610EK(1 or 2) QMB200EK(1 or 2) QMB610EK(1 or 2) QMB200EK(1 or 2)
357. 357. 357. 357. 357. 357. 357. 357. 357. 357. 357. 357.
3 3 7.5 7.5 15 15 25 25 50 75
5 10 20 20 40 50 50
1 indicates one normally open and one normally closed contact. 2 indicates two normally open and two normally closed contacts. Blank units cannot be modified to accept a switch interior. Use 300 Vac Class T fuses only. Class J fuse provisionsto field modify switch, move load side fuse base to position indicated in switch. Not available on 100-30, 100-60 or 800 Ampere switch units. To adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB600T6, $ Price 194. (Use T6 fuses with standard horsepower ratings only). 250 Vdc rating. To adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB800T6, $ Price 467. (Use T6 fuses with standard horsepower ratings only). Use 600 Vac Class T fuses only. Horsepower rating applicable to 480Y/277 V system only.
See Supplemental & Obsolescence Digest for merchandised motor starter units, QMB RTI panelboards and replacement switches for Series 1-4 and D2 QMB panelboards.
9-34
PE1A
Discount Schedule
Table 9.157:
Mains Rating (Amperes) 225 400 600 800 1200 a b c d e
Base $ Price
Main Lugs Maximum Mounting Space (Inches) 60 b 60 b 60 b 60 b 45 Base $ Price (2- or 3-pole) 1098. 1344. 2066. 2550. 3550. Mains Rating (Amperes) 100 b 200 b 400 600 800 Maximum Mounting Space (Inches) 51 51 45 45 45 Main Switch a 240 Vac Base $ Price 2-pole 3-pole 2544. 3104. 2544. 3104. 4840. 6158. 7298.c 8758.c 11098. 13704.c Solid Neutral (Main Lugs and Main Switch) 600 Vac Base $ Price Ampere $ Price Rating 2-pole 3-pole 3026. 3632. 100 294. 3026. 3632. 200 294. 225 294. 5906. 7300. 400 384. 7968.de 9338.d 600 556. 11128.d 13724.d 800 786. 1200 912.
Pricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches. 800 A switch unit with provision for UL Class L fuses. Switches for use with 300 V Class T fuses are also available at no additional cost. For 600 Vac UL Class T fuse provision on main switch, add $ 321.00 250 Vdc rating.
Table 9.158:
Unit Ampere Rating
a 3-pole $ Price 240 Vac Space Only Unit Mounting Height $ Price (Inches) 294. 392. 396. 294. 294. 396. 580. 878. 580. 878. 878. 4.5 6 6 4.5 4.5 6 9 15 9 15 15 2-pole $ Price 852. 1276. 1984. 1216. 1822. 1216.c 1216. 1216.c 1216. 1822.e 1822. 3970. 1984.c 4300.c 4098.cd 4098. 5264.cf 5264. 10682.f 3-pole $ Price 600 Vac Space Only Unit Mounting Height $ Price (Inches) 294. 396. 462. 396. 462. 396. 462. 294. 396. 462. 396. 462. 580. 878. 580. 878. 4.5 6 7.5 6 7.5 6 7.5 4.5 6 7.5 6 7.5 9 15 9 15
Twin Mounted Branch Switches b 30-Blank QMB 60-Blank QMB QMB 100-Blank QMJ c 200-Blank QMJ c 60-30 QMB 100-30 QMB 100-60 QMB QMB 30-30 QMJc QMB 60-60 QMJ c QMB 100-100 QMJc 200-200 Single Mounted Branch Switches 200 QMB 400 QMB 400d QMB 400 QMJ c 600 QMB 600 QMJ c 800g QMB a b c d e f g
592. 898. 1822. 826. 826. 1282. 1484. 3204. 3040.d 4888.e 10682.
784. 1104. 2274. 1120. 1120. 1576. 2034. 4562. 4360.d 6374.ce 10682.e
1012. 1592. 2576. 1446. 2274. 1446. 1446. 2274. 5154. 2576. 5764.c 5552.cd 5552. 6962.cf 6962. 10682.f
Pricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches. $ Price is per twin switch. 250 Vdc rating. For use with Class T fuses only. Use 300 V Class T fuses on 240 Vac max. systems and 600 V Class T fuses on 600 Vac max. systems. Switches for use with 300 V Class T fuses are also available at no additional cost. For 600 Vac UL Class T fuse provision on branch switch, add $ 307.00 800 A switch unit with provision for UL Class L fuses.
Table 9.159:
Accessories
Copper Bus Bars 488. 488. 720. 1148. 1372. 1428.
Electrical Interlocks Mains Ampere Sub-feed Lugs a Feed-through Lugs for Number of Contacts Branch Switches Rating for Main Lugs Interior a Main Switch Interior Normally Open Normally Closed 30200 A $ Price 200 836. 225 282. 400 466. 872.b 1 1 472. 2 2 600 856. 1268.b 800 1150. 1512.b 1200 1440. a b No extra box height required. Box height increases 6 in. Not available in Type 3R/5/12 construction, or with door over QMB option.
Table 9.160:
Left Unit
$ Price3-pole 480 V 600 V HD HG HD HG HD HG 15150 A 15150 A 6 2914. 3572. 3324. 3814. 3674. 4018. Note: See Supplemental & Obsolescence Digest for merchandised motor starter units, QMB RTI panelboards and replacement switches for Series 1-4 & D2 QMB panelboards.
Table 9.161:
Table 9.162:
Starter Size 0 1 2 3
PE1
Discount Schedule
9-35
PANELBOARDS
Common Features
Class 4620 / Refer to Catalog 4620CT9601
www.schneider-electric.us
Table 9.169:
$ Price 180. 148.
9
PANELBOARDS
Equipment Ground Bar Copper Ground Bar (Add to Equipment Ground Bar $ Price) Insulated/Isolated Ground Bar $ Price an Additional Neutral Assembly from Table 9.157 on page 35 for Al insulated ground bar or from Table 9.164 for Cu insulated ground bar. (Add to Equipment Ground Bar $ Price) Name Plates Standard white face/black letter laminated bakelite, 1 in. x 3.5 in. adhesive backed or screw mountable with screws in a bag assembly ($ Price includes engraving)
Aluminum Compression Lugs VCEL 100 A #81/0 Al or Cu 200 A #4300 kcmil Al or Cu 400 A 2/0500 kcmil Al or Cu 600 A 2/0500 kcmil Al or Cu 800 A 2/0500 kcmil Al or Cu or 500 kcmil Cu or 500750kcmil Al.
78.
Table 9.170:
Table 9.164:
Copper Neutral
$ Price 868. 894. 1108. 1352. 1616. N/A 806. 3054.
Copper Neutral 125400 A 600 A 800 A 1200 A 1600 A Hinged Trim Door option for Type 1 enclosure Weatherproof or Dusttight CabinetsType 3R, 5, 12 800 A Maximum Mechanical Lugs 225 A1200 A
Table 9.171:
Voltage Surge Current 120/240 V 208Y/120 V 240/120 Vac 480Y/277 Vac 600Y/347 Vac Rating 34W kA 13W 34W 34W 34W High Leg 100 14310. 15410. 120 15654. 16754. 160 18586. 19686. 200 19196. 23596. 23596. 26896. 26896. 240 23760. 27440. 27440. 31460. 31460.
Standard
Table 9.172: Table 9.165: Copper Mechanical Lugs Main Lug Interiors
$ Price Standard
TVSS Options
$ Price 1650. Standard 2588.
Surgelogic TVSS Options Surge Counter Dry Contacts Remote Monitor a Requires 9 in. of mounting height.
Table 9.166:
Table 9.167:
100 A twin QMB 6" H @ 240 Volt 60 A twin QMB 6" H @ 600 Volt 100 A twin QMB 7.5" H @ 600 Volt 100 A twin QMJ 6" H @ 600 Volt 200 A QMB 9" mounting height, 200 Amp twin QMJ 7.5" mounting height 400 A QMJ 9" H, 400 A Class T 9" H, 400, 600 or 800 A QMB all require 15" H 38"
30/30 @ 240 or 600 V or 60/60 @ 240 V are 4.5" high Wiring Gutter
Table 9.168:
To maximize the quantity of branch switches, use QMJ switches on 9-35. Class K fuses are available in time delay construction suitable for motor and transformer loads.
9-36
PE1
Discount Schedule
Table 9.173:
Table 9.175:
Maximum Ampacity MLO
Ampacity
Square D Type PB b 30 A 2P PBM10B 60 A 2P 75 A 2P 100 A 2P 150 A 2P 200 A 2P 225 A 2P 30 A 3P 60 A 3P 75 A 3P 100 A 3P 150 A 3P 200 A 3P 225 A 3P ASCO Type 920 c 30 A 2P 60 A 2P 75 A 2P 100 A 2P 150 A 2P 200 A 2P 225 A 2P 30 A 3P 60 A 3P 75 A 3P 100 A 3P 150 A 3P 200 A 3P 225 A 3P a b c 9202030 9202060 9202075 9202100 9202150 9202200 9202225 9203030 9203060 9203075 9203100 9203150 9203200 9203225 PBP10B PBN10B PBQ10B PBR10B PBV10B PBW10B PBM11B PBP11B PBN11B PBQ11B PBR11B PBV11B PBW11B
44
3772. 4634. 4986. 5072. 7156. 8692. 9830. 3740. 4754. 5628. 6454. 8078. 8736. 10062.
18 18 18 18 18 18 18 18 18 18 18 18 18 18
56 62
When greater than 125 A lugs are required on the split section of the bus, consult your local Square D/Schneider Electric sales office for box height.
Table 9.176:
Ampacity MLO 225 A 400 A 600 A 800 A 1200 A
4694. 5954. 5954. 6194. 9242. 10882. 11875. 5436. 7638. 7638. 9184. 12998. 14434. 15750.
18 18 18 18 18 18 18 18 18 18 18 18 18 18
Note: For applications with main circuit breaker panelboards, contact the Square D/Schneider Electric local Field Sales Office. a For I-Line panelboards, dimension includes height of SL sub-feed lug kit from Digest, plus 3 in. from available branch mounting space.
(Not UL Listed) $ Price as standard main circuit breaker, No adder See page 7-35 for pricing.
NF panels require 18 in. of additional box height regardless of contactor ampacity or manufacturer. If two-wire control is required Square D Add 708. (No additional width or depth required) If two-wire control is required ASCO Add 1412. (No additional width or depth required)
Table 9.174:
Current Density Rated Panelboard Bus and Special Plating for Copper Bus
Copper Bus Special Plating $ List Price Adder a Tin or Silver Plating Current Density Rated Bus $ List Price Adder 1000 A/in2 Cu 510. 610. 830. 1050. 1490. 1710. 1940. c b 340. b 456. 572. 1244. 1432. Copper (Cu) Only c c c 750 A/in2 Al
Ampacity
1080. cd d d
Standard copper bus plating material NQ and NF: Silver plated bus/tin plated connectors I-Line and QMB: Tin. NQ available in 42 circuit only. Not available in NQ. HCN 600 A and all 8001200 A I-Line interiors available with copper bus only.
Powerlogic meteringa Customer equipment space (NQ and NF)a Increased box deptha Increased gutterstop, bottom and sidesa Non-standard painta Welded base channela Type 1 gasketeda Type 2 drip hooda Type 3R/4/4X/5/12 stainless steel enclosurea Type 4X fiberglass enclosurea Stainless steel trim fronta Padlockable haspa Special locks (Corbin, Yale, Best)a Equal height boxesa Common trim to cover two equal height boxesa Panelboard skirthides conduits feeding a panelboarda Panelboard wirewayfor terminating conduit in wireway endwalla Keyed mechanical interlocking of two or more circuit breakers (I-Line and QMB)a Motor operators (I-Line only) Panelboard interiors and special fronts to fit existing boxes A standard panelboard box has one blank endwall & one with knockouts. Blank endwalls or knockouts in both endwalls are also availablea
Supported by the Panelboard Product Selector
PE1
Discount Schedule
9-37
PANELBOARDS
Type
$ Price
NQ Panelboards125 A Maximum Lugs on Split Bus Section a 18 30 225 A 600. 900. 18 30 30 NF Panelboards125 A Maximum Lugs on Split Bus Section a 18 30 250 A 900. 18 30 30
Panelboards
9
Table 9.177:
Panel Type
PANELBOARDS
a a
NQ
400 600
Table 9.178:
Panel Type
The lug range shown is for the highest amperage of the circuit breaker frame shown in the table.
Table 9.179:
Panel Type
NF
Table 9.180:
Panel Type
NF
The lug range shown is for the highest amperage of the circuit breaker frame shown in the table.
9-38
Terminal Data
Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601
Table 9.181:
Panel Type
I-Line
Table 9.182:
Panel Type
I-Line
Table 9.183:
Panel Type
QMB
Table 9.184:
Panel Type
QMB
Table 9.185:
Panel Type
QMB
Table 9.186:
Panel Type
QMJ
a b
Use only 90oC insulated conductors based on an ampacity of 75oC conductors. (#) = Number of conductors per phase.
9-39
PANELBOARDS
Speed-D Switchboards
9
PANELBOARDS Standard Unit Inverted Unit
Service Applications
Cold Sequence Metering
Standard Unit Inverted Unit
Table 9.187:
System
600 V Max.
Bus Link KitUtilized when installing window type current transformers Ground Fault Protection Factory installed onlyc a b c
Bottom Feed
Top Feed
Includes 8 in. box extension. Kits required per 3 application: 400600 AOrder one kit 8001200 AOrder two kits Must specify feed (top or bottom) and sequence (hot or cold) at the time of order. Ground fault protectionconsists of ground fault relay, ground fault sensor, and display. Available only on 1000 A and 1200 A Units. The Ground fault option adds 8 in. of height to the enclosure (78 in. + 8 in. = 86 in.).
Table 9.188:
Top Feed Bottom Feed
Ampere Rating 400 600 800 1000 1200 a
Lug Table
Main Circuit Breaker Lug Wire Range a (3) 3/0500 kcmil Al or Cu (3) 3/0500 kcmil Al or Cu (3) 3/0500 kcmil Al or Cu (4) 3/0500 kcmil Al or Cu (4) 3/0500 kcmil Al or Cu #6 AWG300 kcmil Al or Cu Ground Lug
CT bus lugs and neutral lugs are identical to the main circuit breaker lugs.
9-40
PE1A
Discount Schedule
NQ Merchandise Panelboards
www.schneider-electric.us
NQ Panelboards
Class 1640
New!
Features
Table 9.189:
New!
Pole Spaces 18 30 30 42 Mains Rating
100 225
Table 9.190:
Total $ Price Interior Only Interior, Front, (Order Branch Circuit Box and Pole Mains Breakers Separately) Spaces Rating Adapter Kit
Type 1 Type 12 Catalog No. $ Price Catalog No. $ Price 15 27 30 42 1407. 100 backfed 1647. 2528. 225 2808. NQ418L1C14 951. NQ430L1C14 1191. NQ430L2C14 1292. NQMB2HJ14 NQ442L2C14 1551. NQMB2Q14
Catalog $ Price Catalog $ Price Catalog $ Price No. No. No. NQB532 118. NQC32( ) 338. N/A Select QOB 3-pole or QOB-VH NQB532 118. NQC32( ) 338. N/A 780. HD, HG, HJ, HL or JD, JG, NQB544 118. NQC44( ) 338. N/A 780. JJ, JL, QB, QD, QG, QJ NQB550 118. NQC50( ) 359. N/A
Note: Copper bussing standard. Add F for flush, S for surface. SFL, TFL and SFC/B are not available (add footnote letter).
New!
PE1A
Discount Schedule
9-41
240 Vac, 48 Vdc maximum 225 A maximum main circuit breaker or main lugs 100 A maximum branch circuit breakers Visi-Trip indication on branch circuit breakers 10,000 A through 65,000 A Short Circuit Current Rating (SCCR) Interiors supplied with tin plated copper bus as standard Interiors accept both bolt-on and plug-on branch circuit breakers Three-phase, four-wire interiors available Panelboards available with Mono-Flat front Suitable for use as service entrance equipment Branch circuit filler plates provide fast and easy installation Both fully and series rated systems are available
PANELBOARDS
www.schneider-electric.us
9
PANELBOARDS
9-42
Table of Contents
Section 10
Integrated Power and Control Solutions (IPaCS) Equipment
IPaCS Equipment Overview Modular Panelboard System Integrated Power Center Standby Power Quick Connect Tap Box Submetering Integrated Power Center Integrated Power Center 2
Integrated Power Center 2 Integrated Power Center 2 Transformer Combo
MPS, see page 10-3
10-2 10-3 10-3 10-4 10-4 10-4 10-4 10-5 10-5 10-6
INTEGRATED POWER AND CONTROL SOLUTIONS (IPACS) EQUIPMENT
Integrated Power Center 2 Transformer Combo Merchandise Specifications Integrated Power Center 2 Transformer Combo Merchandise Configurations
10-1
10
IPaCS Equipment
Overview
Class 2200 / Refer to Documents 2230DB0601, 2010CT0001 and 2735CT0001
www.schneider-electric.us
10
INTEGRATED POWER AND CONTROL SOLUTIONS (IPACS) EQUIPMENT
The IPC2 Transformer Combo has been recognized by the electrical industry by winning the following awards: 2006 INNOVATION Award given by the Electrical Contracting Products magazine 2006 Product of the Year Gold Medal Award given by the Consulting/Specifying Engineer magazine 10-2
2009 Schneider Electric All Rights Reserved
IPaCS Equipment
www.schneider-electric.us
Typical applications for MPS equipment include: Restaurants / Food service Office buildings / Public buildings Warehouses Schools / Universities
MPS Interior
Typical applications for IPC equipment include: Retail stores / Grocery stores Office buildings / Public buildings Shopping malls / Strip malls Schools/Universities Restaurants / Food service Hotels/Motels Warehouses Equipment rooms
MPS and IPC lineups are shipped factory-assembled and pre-wired. Customers may specify single- or multiple-section shipping splits (some limitations apply). In addition, lineups may be ordered with or without factory-installed power cables. 10-3
10
IPaCS Equipment
Rated for 800 A maximum at 600 V maximum Generator connection lugs (lug-in) are suitable for use with Type W cable; Standby power disconnect lugs (lug-out) are standard mechanical lugs Designed, manufactured and tested to UL 1773 standards Lugs are marked for connection sequence (G, N, A, B, C)
The SPQCL Tap Box uses cam-lock receptacles for generator connection. Key design features include:
Standby Power Quick-Connect Tap Box Rated for 600 A maximum at 600 V maximum Provided with color-coded cam-lock receptacles male end Designed, manufactured and tested to UL 1008 SB standards Cam-locks are marked for connection sequence (G, N, A, B, C)
10
INTEGRATED POWER AND CONTROL SOLUTIONS (IPACS) EQUIPMENT Submetering Integrated Power Center Integrated Power Center 2
Panelboards PowerLogic E4800 Multi-Circuit Energy Meters and associated CTs Surge Suppression Factory-installed wiring between components
Submetering IPC width and height dimensions vary depending on the application. All sections are 10.5 in. (266.7 mm) deep. Typical applications for Submetering IPC equipment include:
Office towers Condominiums Apartment buildings Shopping centers Other multi-user environments Configurations with 2-PowerLogic E4800 meters plus Ethernet switch when required based on the number of metered points
K-rated and HMT also available; may limit max kVA size of transformer
Individually-mounted circuit breakers Surge Suppression: TVSS integral to panel and/or separately mounted Automatic Transfer Switch: Open type 400 A 3-pole maximum including a variety of options Lighting Controls: Powerlink or lighting contactors PowerLogic Monitoring / Metering: power meters, circuit monitors, branch circuit monitoring, and system display meters Building Management Systems
As a stand-alone solution, the IPC2 family provides the flexibility to enter and/or exit the section from either the top or bottom. IPC2 is offered in a variety of widths and depths:
2448 in. (6101219 mm) Wide 2436 in. (610915 mm) Deep
IPC2 Shipping
IPC2 lineups are shipped fully-assembled, completely-tested, and ready-to-install. Customers may specify single- or multiple-section shipping splits (some limitations apply). In addition, lineups may be ordered with or without factory-installed power cables.
10-4
IPaCS Equipment
www.schneider-electric.us
Table 10.2:
NF Panelboard 480Y/277 V 3 4W 225/3 MB 18 k AIC 1125/3 (Transformer) 39-1PSO Copper Bus / Ground Bus SUSE Catalog No. IPC2TC-2EE NF Panelboard 480Y/277 V 3 4W 400 A MLO 18 k AIC 1125/3 (Transformer) 39-1PSO Copper Bus / Ground Bus SUSE Catalog No. IPC2TC-3EE NQ Panelboard 208Y/120 V 3 4W 225/3 MB 10 k AIC 42-1PSO Copper Bus / Ground Bus FT Lugs
NQ Panelboard 208Y/120 V 3 4W 225 A MLO 10 k AIC 42-1PSO Copper Bus / Ground Bus
NF Panelboard 480Y/277 V 3 4W 400 A MLO 18 k AIC 1175/3 (Transformer) 30-1PSO Copper Bus / Ground Bus SUSE Catalog No. IPC2TC-5EE NF Panelboard 480Y/277V 3 4W 400/3 MB 18k AIC 1-125/3 (Transformer) 27-1PSO Copper Bus/Ground Bus SUSE Catalog No. IPC2TC-6EE NF Panelboard NQ Panelboard 480Y/277 V 3 4W 225/3 MB 18 k AIC 1125/3 (Transformer) 39-1PSO Copper Bus / Ground Bus SUSE Catalog No. IPC2TC-7EE 480Y/277 V 3 4W 125 A MLO 18 k AIC 160/3 (Transformer) 15-1PSO Copper Bus / Ground Bus SUSE Catalog No. IPC2TC-8EE NF Panelboard 480Y/277 V 3 4W 125 A MLO 18 k AIC 140/3 (Transformer) 15-1PSO Copper Bus / Ground Bus SUSE
NQ Panelboard
208Y/120 V 3 4W 225 A MLO 10k AIC 42-1PSO Copper Bus / Ground Bus
480 V208Y/120 V 3 75 kVA Energy Efficient transformers in compliance with the 2005 Energy Act 150 C Temp Rise Aluminum Windings 6-2.5% Taps; 2+ 4Transformer
NF Panelboard
NQ Panelboard
480 V208Y/120 V 3 45 kVA Energy Efficient transformers in compliance with the 2005 Energy Act 150 C Temp Rise Aluminum Windings 6-2.5% Taps; 2+ 4Transformer
NQ Panelboard
480 V208Y/120 V 3 30 kVA Energy Efficient transformers in compliance with the 2005 Energy Act 150 C Temp Rise Aluminum Windings 6-2.5% Taps; 2+ 4-
10-5
10
IPaCS Equipment
Sample Lineups
Class 2200 / Refer to Documents 2230DB0601 and 2010CT0001
www.schneider-electric.us
42 in.
42 in.
42 in.
42 in.
91.5 in.
91.5 in.
91.5 in.
91.5 in.
10
INTEGRATED POWER AND CONTROL SOLUTIONS (IPACS) EQUIPMENT
24 in. 24 in. 24 in. 24 in.
IPC2TC-1EE
IPC2TC-2EE
IPC2TC-3EE
IPC2TC-4EE
42 in.
48 in.
24 in.
24 in.
1 1 2 3
91.5 in.
91.5 in.
2 1
91.5 in.
91.5 in.
24 in.
24 in.
24 in.
24 in.
IPC2TC-5EE
IPC2TC-6EE
IPC2TC-7EE
IPC2TC-8EE
NOTE: All sections have both top and bottom conduit entry/exit points.
10-6
Table of Contents
Section 11
Switchboards and Switchgear
Power-Style Switchboards
Power-Style QED-S Switchboard (UL Listed) Power-Style QED-2 Switchboard (UL Listed) Power-Style QED-6 Switchboard (UL Listed) Power-Style Commercial Multi-Metering Switchboards Speed-D SB/SF Switchboards (UL Listed) 11-2 11-2 11-3 11-3
11-4, 11-5
Power-Zone 4 Low Voltage Switchgear with Masterpact Circuit Breakers Micrologic Trip Units MiniBreak Compact Height Switches 5.5 kV200 A HVL/cc Metal-Enclosed Load Interrupter SwitchgearFull Range HVL/cc SwitchgearQuick Ship Program515 kV, 600 A HVL Metal-Enclosed Load Interrupter SwitchgearFull Range HVL SwitchgearQuick Ship Program 5 kV15 kV, 600 A Features HVL Switches for Power-Dry II , Power-Cast II , and Uni-Cast II Transformer Connections Square D brand DIN/E Fuse Selection TablesHVL Fuse Selection Tables Boric Acid FusesHVL Masterclad Medium Voltage Metalclad Switchgear (UL Listed)
11-6 11-6 11-7 11-8 11-9, 11-10 11-11 11-11 11-12, 11-13 11-14 11-14 11-15 11-15
Unit Substations
Unit Substations Power-Zone Model III Package Unit Substations 11-16 11-16
SWITCHBOARDS AND SWITCHGEAR
11-18 11-18
11-1
11
Power-Style Switchboards
Power-Style QED-S Switchboard (UL Listed) Front accessible load connections Front and rear alignment standard Switchboard fed by cable Switchboard ratings through 4000 A, 200 kA Thermal-magnetic, electronic, and Micrologic fixed-mounted circuit breaker mains
QED-S Switchboard (Class 2741)
and feeders Stored energy fixed-mounted mains Fixed-mounted fusible switch mains and feeders Group-mounted circuit breaker and fusible switch mains and feeders Main devices in six sub-division or single main configurations Main and branch devices in single section configuration Multiple individual devices in single section configurations Main lugs in separate section in lineup or behind devices Thermal-magnetic circuit breakers with standard, high, extra-high, or current-limiting capability Electronic circuit breakers with standard, high, or extra-high capability Exclusive Micrologic microprocessor trip circuit breakers, 80% or 100% rated Selected utilities and Powerlogic customer metering Selected options on circuit breakers and fusible switches Internally mounted Surgelogic Transient Voltage Surge Suppression (TVSS) optional
Power-Style QED-2 Switchboard (UL Listed) Front accessible load connections Front and rear alignment standard Switchboard fed by cable, busway, transformer, or QED switchboard Switchboard ratings through 5000 A, 200 kA; higher amperages available Thermal-magnetic, electronic, and Micrologic, or stored energy fixed- and drawout
QED-2 Switchboard (Class 2742)
mounted, circuit breaker mains and feeders Fixed-mounted fusible switch mains and feeders Group-mounted circuit breaker and fusible switch mains and feeders Main devices in six sub-division or single main configurations Main and branch devices in single section configuration Multiple individual devices in single section configurations Main lugs in separate section in lineup or behind devices Group-mounted mains and branches Thermal-magnetic circuit breakers with standard, high, extra-high or current-limiting capability Electronic circuit breakers with standard, high, or extra-high capability Exclusive Micrologic microprocessor trip circuit breakers, 80% or 100% rated All utilities Powerlogic customer metering, including custom communications capability and interwiring Transparent Ready Equipment communications Zone selective interlocking on Micrologic circuit breakers, and group mounted 100/250 A thermal-magnetic circuit breakers with add-on ground-fault and bolted pressure fusible switches All options available on circuit breakers and fusible switches Custom engineering including main-tie-mains, multiple sets of thru-bus, reduced heights, and engineered houses Internally mounted Surgelogic TVSS option
11
SWITCHBOARDS AND SWITCHGEAR
11-2
Power-Style Switchboards
www.schneider-electric.us
System Coordination
Short-time ratings are high, giving users excellent system coordination and selectivity with downstream breakers.
Ability to Upgrade
UL Listed, field-installable accessories include: motor operators, shunt trips, under voltage devices, trip units, and communication modules for trip units. Manually operated circuit breakers are field convertible to electrical operation.
Adaptable
Drawout and bolt-in circuit breakers, front access control wiring, and expandable lineups are quickly adaptable to changing load and control requirements. Masterpact NW and NT circuit breakers have many control termination points, giving the equipment extensive flexibility and expandability for sophisticated control schemes.
SWITCHBOARDS AND SWITCHGEAR
Expandable
QED-6 switchboards are reliable power protection equipment when working with telecommunication facilities, e-business servers, or mainframes that perform critical business transactions. These types of facilities cannot afford downtime. QED-6 rear-connected switchboards are designed as standalone switchboards or as an integral part of the low voltage equipment lineup in a users power unit substation.
Commercial Specify QED-6 Switchboards Multi-Metering Switchboard When drawout construction is required for quick circuit (Classes 2755, 2756)
breaker changeout; system requirements call for circuit breakers to close within five cycles; stored energy circuit breakers are required; front access to control wires is desired; ease of installation, maintenance, and upgrade of circuit breaker compartmentalization is required; system integrity and segregation of circuit breaker compartments from bus and cable compartments is required; equipment isolation is required.
configuration Tenant mains either circuit breaker or fusible 60200 A without lever bypass with self-contained meter sockets, 5- or 7-jaw, ring type and test block where required 60200 A lever bypass with self-contained meter sockets, 7-jaw, ringless Factory-installed devices with completely wired from meter socket to disconnect Provisions for adding future tenants available, as well as future sections Sections in either NEMA 1 or NEMA 3R construction For use on 120/240, 120/208, and 277/480 volt systems Integrated, front-accessible wireway for top exiting load cables Customer access area for top exiting load cables
11-3
11
Power-Style Commercial Multi-Metering Switchboards UL Listed Lever bypass and EUSERC non lever bypass Hot sequence meteringEUSERC, NEMA, LOCAL Front and rear alignment standard Switchboard ratings through 4000 A, 100 kA Meter sections in either three- or six-socket section
Speed-D Switchboards
Class 2710 / Refer to Pricing List 2710PL9602
www.schneider-electric.us
Speed-D SB/SF Switchboards (UL Listed) UL Listed Hot sequence utility compartment per EUSERC requirements Two types:
UtilityService disconnectdistribution UtilityUp to six service disconnects
Enclosure
Totally enclosed front accessible with ANSI 49 gray baked enamel finish. Dimensions are 90 in. (H) x 36 in. (W) x 14 in. (D) for indoor and 90 in. (H) x 36 in. (W) x 24.5 in. (D) for outdoor enclosures.
Single service disconnect, either circuit breaker or fusible rated 400, 600, or 800 A with either type of distribution interiors, NQOD up to 240 Vac, I-Line through 480 Vac Six service disconnects, group-mounted fusible, QMB/QMJ, 30400 A; utility compartment400, 600, and 800 A Meter doors can be 15 inches high with one meter socket and test block, or 30 inches high with two meter sockets and test block Meter sockets can be 6-, 8-, 13-, or 15-jaw meter sockets with test block, based on application Accessories include: Underground pull sections with and without lug landing Loadside wireway Bus links for donut-type current transformers Double padlock hasp attachments Plug-on distribution panel Subfeed circuit breakers Full height add-on I-Line distribution section Stand-alone I-Line distribution section
EUSERC Utility Metering, Main Disconnects and Distribution Panel (UL Listed)
Table 11.2:
System Service Voltage
65 65 65 65 65
208Y/120 34Wa 240/120 400 NQOD 65 SB324QS 7491.00 SB324QR 11168.00 208Y/120 34Wa 240/120 400 None 65 SB324WS 6927.00 SB324WR 10604.00 208Y/120 34Wa 240/120 400 I-Line 65 35 SB344IS 8555.00 SB344IR 12185.00 480Y/277 208Y/120 34Wa 240/120 400 None 65 35 SB344WS 7653.00 SB344WR 11283.00 480Y/277 208Y/120 34Wa 240/120 600 I-Line 65 50 SB346IS 10761.00 SB346IR 14130.00 480Y/277 208Y/120 34Wa 240/120 600 None 65 65 SB346WS 9860.00 SB346WR 13229.00 480Y/277 208Y/120 34Wa 240/120 800 I-Line 65 50 SB348IS 19569.00 SB348IR 22038.00 480Y/277 208Y/120 34Wa 240/120 800 None 65 65 SB348WS 18669.00 SB348WR 21137.00 480Y/277 a Can be used on 33W Delta voltage systems (for example, 240 V Delta or 480 V Delta).
Table 11.3:
13W 120/240
11
SWITCHBOARDS AND SWITCHGEAR EUSERC UCT, Single Main Circuit Breaker with I-Line Distribution Panel EUSERC UCT, Fusible Multiple Mains
Application
Suitable for use as service entrance equipment on ac systems. Sections contain metering compartment, barriers, main disconnects, distribution panel, neutral bus, and grounding provisions.
Metering
C/T compartment with two 15-inch blank meter doors. (Order doors with meter socket from Table 11.6 on page 11-5.) Incoming cable lugs are for top feed with one twin conductor 2 AWG600 kcmil lug per phase and neutral, suitable for aluminum or copper cables. Optional single conductor lug is available. Refer to Table 11.7 on page 11-5.
208Y/120 34Wb 240/120 400 NQOD 65 SF324QS 7476.00 SF324QR 11157.00 208Y/120 34Wb 240/120 400 None 200 SF324WS 6912.00 SF324WR 10593.00 208Y/120 34Wb 240/120 400 I-Line 100 65 SF344IS 8564.00 SF344IR 12189.00 480Y/277 208Y/120 34Wb 240/120 400 None 200 200 SF344WS 7662.00 SF344WR 11288.00 480Y/277 208Y/120 34Wb 240/120 600 I-Line 100 65 SF346IS 10761.00 SF346IR 14387.00 480Y/277 208Y/120 34Wb 240/120 600 None 200 200 SF346WS 9860.00 SF346WR 13485.00 480Y/277 208Y/120 800 I-Line 100 65 SF348IS 25401.00 SF348IR 28782.00 34Wb 240/120 480Y/277 208Y/120 34Wb 240/120 800 None 200 200 SF348WS 24501.00 SF348WR 27881.00 480Y/277 b Can be used on 33W Delta voltage systems (for example, 240 V Delta or 480 V Delta).
Table 11.4:
System
Mains
Main circuit breaker types are either LH or MH. Main fusible device is supplied with Class T fuses. Multiple main devices use plug-on fusible switches.
Service Voltage
Branches
NQOD distribution bus is rated 400 A and provides mounting space for QO/QOB Type (150 A maximum) circuit breakers. Panel provides space for mounting 42 single pole circuit breakers. One or two individually mounted 225 A maximum circuit breakers can be added with bus connectors. (Order subfeed circuit breakers from Table 11.8 on page 11-5.) I-Line distribution bus is rated 400, 600, or 800 A and will accept 27 inches of I-Line circuit breakers on the left side maximum frame size of J or K. The right side will accept either a QO plug-on distribution panel (240 V only) or LA or LH I-Line circuit breaker.
120/240 400 200 5565.00 8478.00 120/240 600 200 5934.00 8966.00 208Y/120 240/120 34We 400 200 SF344FS 7025.00 SF344FR 10050.00 408Y/277 208Y/120 240/120 34We 600 200 SF346FS 7319.00 SF346FR 10233.00 480Y/277 208Y/120 240/120 34We 800 200 SF348FS 8283.00 SF348FR 11199.00 480Y/277 c Multiple mainsprovisions for mounting 30 inches of fusible devices. No more than six main devices permitted per NEC. d QMB/QMJ fusible switches, maximum 400 A, SCCR based on Class J, R, or T fuses. QMB plug-in circuit breaker rating is equal to the lowest rating of the circuit breaker. e Can be used on 33W Delta voltage systems (for example, 240 V Delta or 480 V Delta). 13W 13W
11-4
PE1A
Discount Schedule
Speed-D Switchboards
www.schneider-electric.us
Table 11.5:
System
34W 34W
SBAD800R 13305.00
Table 11.6:
Meter Socket Jaws
Catalog No. $ Price Catalog No. 6a SBA15D6MS 923.00 8 SBA15D8MS 984.00 13 SBA15D13MS 1230.00 SBA30D13MS 15 SBA15D15MS 1358.00 SBA30D15MS Blank SBA15DBC 495.00 b SBA15DMS 617.00 a 6-jaw meter socket can also be used on 4- and 5-jaw applications. b Door with provisions for mounting meter socket. Note: To order structure with meter door factory-installed, add door catalog number as suffix to structure (e.g. SF344IS-15D13MS).
Table 11.7:
Accessories
Catalog No. SA26PS SA26PSR SA8LLc SA7PL SA10LW SA10BL SS2PL System Phase AC ABC AB Pole Spaces 12 SS212AC SS312 SS212ABd 2339.00 2957.00 2339.00 $ Price 2217.00 4559.00 753.00 395.00 1052.00 246.00 113.00
Description Indoor underground pull section (w/o lug landing)26-in. (W) Order separate SA8LL lug kit below if required. Outdoor (3R) underground pull section (w/o lug landing)26 in. (W) x 24.5 in. (D) Order separate SA8LL lug landing kit below when required. Lug landing kit800 A max. For terminating utility service cables in indoor or outdoor underground pull sections. Single barrel lug kit Kit provides single barrel lugs and pad in lieu of twin barrel lug provided with service section. Mechanical lugs provided are sized to fit 1-3/0750 kcmil cable. Two lugs per phase are supplied. Loadside wireway11.5 in. (W) x 14 in. (D)indoor only Bus link kit800 A max.Order one kit per phase for 400, 600, and 800 A. Double padlock hasp attachmentFor mounting two padlocks on door handle of rainproof enclosure. Padlocks not included. Plug-On Distribution Panelmounts on right side of I-Line interior. Cannot be used with LA/LH branch circuit breaker. Panel rated 225 A for 240 V applications. For QO type plug-on circuit breakers only. c d All EUSERC Utilities (except Arizona Public Service and Salt River Project) require a lug landing kit SA8LL. To be used on 120/240 V, 34W delta applications.
1 3 3
Table 11.8:
Ordering Information
1. Service section: Order service section from either Table 11.2 on page 11-4 (single main circuit breaker with distribution), Table 11.3 on page 11-4 (single main fusible with distribution), or Table 11.4 on page 11-4 (multiple mains fusible), as determined by mains rating, voltage, and system. 2. Meter doors: Order meter door from Table 11.6 (meter door selection) as determined by the height and utility metering requirements. 3. Accessories and subfeeds: Order as required from Table 11.7 (accessories) and/or Table 11.8 (subfeed circuit breakers). 4. Circuit breakers and switches: Order devices from pages listed below as determined by voltage, trip rating, AIR, and mounting space. Multiple Mains and Branch Devices QO, QOB, QO-VH, QOB-VH: pages 7-10 and 9-10 I-Line: pages 9-23 to 9-27 QMB Switches: page 9-34
PE1A
Discount Schedule
11-5
11
Left Right Left 100 SASFB100L( ) SASFB100R( ) 1148.00 SASFB100L 110 SASFB110L( ) SASFB110R( ) 1148.00 SASFB110L Subfeed Circuit Breaker Kit 125 SASFB125L( ) SASFB100R( ) 1148.00 SASFB125L Price includes circuit breaker, connectors and mounting hardware. The complete kit, mounting hardware, circuit 150 SASFB150L( ) SASFB150R( ) 1148.00 SASFB150L breaker and connectors will be shipped direct from plant. 175 SASFB175L( ) SASFB175R( ) 1148.00 SASFB175L Delivery is stock to three days. 200 SASFB200L( ) SASFB200R( ) 1148.00 SASFB200L 225 SASFB225L( ) SASFB225R( ) 1148.00 SASFB225L e Cannot use subfeed circuit breaker kit with multiple mains service section switchboards. f Two pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix (e.g. SASFB100LAC).
Switchgear
11
SWITCHBOARDS AND SWITCHGEAR
Table 11.9:
Masterpact NW
Rating (A)
800
1600
2000
3200
11-6
Switchgear
www.schneider-electric.us
Table 11.13:
Factory Modifications
$ Price 152.00 341.00 1150.00 1772.00 1618.00 1926.00
Catalog No. Description HVMX1 Auxiliary switch, 1-N.O. and 1-N.C. contacts Provisions for lock open only key interlock (does not HVMK1 include the key cylinderorder separately) HVMH1 Strip heater 100 W @ 120 V HVMH2 Strip heater with thermostat 100 W @ 120 V HVMSA3 Distribution class surge3arrester MCOVc (set of three arresters) kV, 2.55 HVMSA6 Distribution class surge6arrester MCOVc (set of three arresters) kV, 5.10 c Arresters are line side connected.
Pricing Example
Price one (1), 5 kV, 200 A switch with 65E current-limiting fuses. Provide one auxiliary switch with 1-N.O. and 1-N.C. contact and with provision for installing a lock open key interlock on the switch operating mechanism.
Order: Switch with enclosure Auxiliary switch Key interlock adapter Fuses (set of three, from page 11-14) Catalog No. HVMB305200 HVMX1 HVMK1 5GS065 $ Price 11844.00 152.00 340.00 1980.00
25.15 2.20
56 639
25.20
640
Ordering Information
Table 11.11:
Type
5 kV200 A Switch
Switch Catalog No. HVMB305200U HVMB305200
66.00
1677
Unfused Fused
47.52
1207
29.00
25.20
640
25.15
639
2.20
56
20.75
527
Table 11.12:
23.78 18.38
467 604
Continuous Current
2.70
69
5 kV Fuse 10E 5GS010 15E 5GS015 D 12 954.00 20E 5GS020 25E 5GS025 30E 5GS030 40E 5GS040 50E 5GS050 D 12 1980.00 65E 5GS065 80E 5GS080 100E 5GS100 125E 5GS125 150E 5GS150 D 12 3326.00 175E 5GS175 200E 5GS200 a Contact your Schneider Electric representative for current stock quantities. b Price includes one set of three fuses, packed in a single box.
1207
15.35
390
PE5A
Discount Schedule
11-7
11
47.52
1. Select switch catalog number based on fused or unfused. 2. Select catalog numbers for modifications from Factory Modifications table. 3. If fused, select 5 kV, 200 A maximum current-limiting fuse from table below. 4. Price switch and fuses separately. Switches are furnished with provisions only for fuses. 5. Weight 450 lbs (204 kg).
737
Front view
Switchgear
Front Optional low voltage compartment Main bus compartment Switch with enclosure Mechanism compartment Fuse cable compartment Fuse/cable access panel
Fuselogic
Fuselogic is a protection system that provides the ultimate in medium voltage fuse protection. This patented system utilizes Square D brand current-limiting fuses with mechanical sensors that function without any auxiliary power requirements. Several combinations of Fuselogic functions can be combined to provide simple blown fuse indication contacts with mechanical lockout to anti-single phasing protection. Anti-single phasing requires the optional stored energy mechanism (SEM). Fuselogic is available on both HVL/cc and HVL switches.
37.25
946
The HVL/cc switch can be equipped with either an overtoggle mechanism (OTM), which is standard, or an optional stored energy mechanism (SEM). An option with both mechanisms is the Fuselogic system. The Fuselogic system offers fuse tripping (with SEM) to provide protection against single phasing loads when a fuse has blown. It also has a mechanical interlock to prevent inadvertent switching until fuses have been installed or blown fuses have been replaced. The HVL/cc enclosure is designed for front access only and can be positioned against walls, in small rooms or in pre-fabricated buildings. The small footprint can result in considerable cost savings from the reduction of building or room sizes. Table 11.14: HVL/cc Load Interrupter Switches Full Range 600/1200 A Ratings
5.5 60 50/60 19 600/1200 600/1200 40 40 25 17.5 95 50/60 36 600/1200 600/1200 40 40 25 17.5 110 50/60 36 600/1200 600/1200 40 40 25 25.8 125 50/60 50 600 600 32 32 25 100 1000 38 150 50/60 80 600 600 32 32 25 100 1000
Compartments: Switch, bus, fuse/cable, mechanism, and optional low voltage/control 11 gauge steel enclosure Epoxy insulators Fuse/cable access panel interlocked with switch Front access only Animated mechanism mimic bus Padlocking open or closed provision Top or bottom cable entry UL/CUL Listed Live line indicators on all incoming switch bays and outgoing feeder circuits Cable lugs included for one cable per phase Tin plated copper bus for lineups Surge Arresters
Arrester MCOV-kV Effectively Impedance Grounded Grounded and Ungrounded Neutral Circuits Circuits 2.55 2.55 5.1 5.1 7.65 7.65 12.70 7.65 12.70 8.4 8.4
90.00
2286
Table 11.15:
System L-L Voltage kV Nominal 2.4 4.16 4.8 6.9 12.0 12.47 13.2 13.8 Maximum 2.54 4.4 5.08 7.26 12.7 13.2 13.97 14.52
37.25
946
14.75
375
Plan View
Front View
Switch (kV) maximum design BIL (kV) Frequency (Hz) Withstand (kV) Continuous current (A) Interrupting current (A) Fault close (kA asymmetrical) Momentary current (kA asymmetrical) Short time current (kA symmetrical) Electrical endurance (number of operations at 80% P.F.) Mechanical endurance (number of operations)
11
SWITCHBOARDS AND SWITCHGEAR
To Ground Bus Open Position To Ground Bus Grounded Position
Switch Positions: Closed, open, and internally grounded (optional) (connects switch contacts to ground) Enclosure: Epoxy Medium: Sulphur hexalfluoride Maintenance: Maintenance free sealed for life Pressure: 5.8 PSI (17.5 kV) 22 PSI (25.838 kV) View ports to show switch blade position Internal ground switch: Has full fault making capability Fuselogic system Infrared viewing windows Class I, Division 2 Fast auto transfers Duplex configurations Protective relaying Powerlogic metering 20-inch or 29.5-inch wide enclosures
Options
11-8
Switchgear
www.schneider-electric.us
NOTE: Cable entry and exit must be opposite to maintain the minimum sections shown.
Three-pole, 600 A individual HVL/cc switches are available in free-standing indoor (NEMA 1) enclosures. These M switches are available unfused or with provisions for 90.00 450E Square D brand current-limiting DIN/E fuses. Factory 2286 M optional accessories include auxiliary bays, main bus, auxiliary switches, extra cable terminating lugs, and distribution class surge arresters. The fuse access panel is mechanically interlocked with the switch mechanism. Key 37.25 interlocks are not an available option with Digest-listed 946 14.75 375 HVL/cc switches. (1) Set screw type lugs for (2) #2350 kcmil copper or aluminum cables are provided for line and 5 kV Indoor N1 Top Cable In/Bottom Cable load connections. Fuses are not furnished with this Out Switch in Position A equipment. For fuse information and pricing refer to page 11-10.
For top incoming cable to application B (top cable exit) switch(es), order 600 A tin plated Cu main bus to adjacent section from main bus kits table. Includes (1) set screw lug for (2) #2350 kcmil Cu or Al conductor per phase. Table 11.19:
Catalog No. HVLCCB14A HVLCCB20A
600 A Tin Plated Copper Main Bus Kits Provisions for Future Expansion
Mechanical interlock between switch and fuse access panel. NOTE: Mechanical interlock is standard on switches.
Left (From) Application Width in 14.75 14.75 20.00 20.00 14.75 14.75 20.00 20.00 mm 375 375 508 508 375 375 508 508 Right (To) Application
All single HVL/cc switches have provisions for future expansion on either side. Order main bus kits for copper 600 A bus. Include sketch for factory-assembled parts or lineups.
Table 11.20:
Catalog No. HVLCCMBA14A14 HVLCCMBA14A20 HVLCCMBA20A14 HVLCCMBA20A20 HVLCCMBB14B14 HVLCCMBB14B20 HVLCCMBB20B14 HVLCCMBB20B20
Bus Kits
Width in 14.75 20.00 14.75 20.00 14.75 20.00 14.75 20.00 mm 375 508 375 508 375 508 375 508 $ Price 882.00 946.00 946.00 1008.00 882.00 946.00 946.00 1008.00
A A A A B B B B
A A A A B B B B
Ratings
HVL/cc Switch with manually operated type OTM mechanism in cubicle enclosure (does not include internal ground switch). Ratings are based on an X/R ratio of 1.6. Table 11.21: HVL/cc Switch Ratings
SWITCHBOARDS AND SWITCHGEAR
5.5 60 50/60 19 600 600 40,000 65,000 40,000 25,000 100 1000 17.5 95 50/60 36 600 600 40,000 65,000 40,000 25,000 100 1000 Switch (kV)maximum design BIL (kV) Frequency (Hertz) Withstand (kV) Continuous current (amperes) Interrupting current (amperes) Fault close (amperes asymmetrical) Integrated switch and fuse rating (amperes symmetrical)a Momentary current (amperes asymmetrical) Short time current, 2 seconds (amperes symmetrical) Operations at Full Load Mechanical Endurance (number of operations) a 50,000 for 630 A fuse.
90.00
2286
450E
Catalog No. HVLCCA14305N HVLCCA20305N HVLCCA14315N HVLCCA20315N HVLCCB14305N HVLCCB20305N HVLCCB14315N HVLCCB20315N
14.75
375
37.25
946
Factory Modifications
Table 11.22:
Catalog No. HVLCC-X3
Factory Modifications
Description Auxiliary switch 2 N.O.2 N.C. contact $ Price 762.00
Table 11.23:
19392.00 19916.00 19858.00 20382.00 19392.00 19916.00 19858.00 20382.00 Catalog No. HVLCCDSA3 HVLCCDSA6 HVLCCDSA9 HVLCCDSA10 HVLCCDSA12 HVLCCDSA15 HVLCCDSA18
Surge Arresters
kV Rating 3 kV, 2.55 kV MCOV 6 kV, 5.10 kV MCOV 9 kV, 7.65 kV MCOV 10 kV, 8.40 kV MCOV 12 kV, 10.20 kV MCOV 15 kV, 12.70 kV MVOV 18 kV, 15.3 kV MCOV Section Width Minimum Required in 14.75 14.75 14.75 14.75 14.75 20.00 20.00 mm 375 375 375 375 375 508 508 $ Price 1618.00 1926.00 2248.00 2446.00 2836.00 3424.00 3948.00
PE5A
Discount Schedule
11-9
11
Switchgear
600 A Single HVL/cc Switch with PROVISIONS ONLY for Square D brand Current-Limiting, Non-Disconnect Type Fuses for Cable Connection to Power-Dry, Power-Cast, and Uni-Cast Transformers (FLC = 300 A MAXIMUM) RHTransformer on right, LHTransformer on Left Application A = Top Entry (Incoming Cables) Application B = Bottom Entry (Incoming Cables) Table 11.24:
Catalog No.
90.00
2286
200E
M
600 A Duplex HVL/cc Switch with PROVISIONS ONLY for Square D brand Current-Limiting, Non-Disconnect Type Fuses for Cable Connection to Power-Dry, Power-Cast, and Uni-Cast Transformers (FLC = 300 A MAXIMUM) RHTransformer on Right, LHTransformer on Left Includes Mechanical Interlock to Prevent Paralleling of Sources Application A = Top Entry (Incoming Cables) Application B = Bottom Entry (Incoming Cables) Table 11.26: 600 A Duplex HVL/cc Switch Selection
Width Catalog No. kV Fuse Rating Range Application RH / LH $ Price
14.75
375
14.75
375
37.25
946
HVLCCA14405DGR 4.76 10450E A 14.75 375 RH 20134.00 HVLCCA20405DGR 4.76 10450E A 20.00 508 RH 20660.00 HVLCCA14405DGL 4.76 10450E A 14.75 375 LH 20134.00 HVLCCA20405DGL 4.76 10450E A 20.00 508 LH 20660.00 HVLCCA14415DGR 15 10200E A 14.75 375 RH 20614.00 HVLCCA20415DGR 15 10200E A 20.00 508 RH 21138.00 HVLCCA14415DGL 15 10200E A 14.75 375 LH 20614.00 HVLCCA20415DGL 15 10200E A 20.00 508 LH 21138.00 HVLCCB14405DGR 4.76 10450E B 14.75 375 RH 20134.00 HVLCCB20405DGR 4.76 10450E B 20.00 508 RH 20660.00 HVLCCB14405DGL 4.76 10450E B 14.75 375 LH 20134.00 HVLCCB20405DGL 4.76 10450E B 20.00 508 LH 20660.00 HVLCCB14415DGR 15 10200E B 14.75 375 RH 20614.00 HVLCCB20415DGR 15 10200E B 20.00 508 RH 21138.00 HVLCCB14415DGL 15 10200E B 14.75 375 LH 20614.00 HVLCCB20415DGL 15 10200E B 20.00 508 LH 21138.00 NOTE: Switches with transformer connections are painted ANSI 49. Standalone switches are painted ANSI 61. Transformer connections in HVL/cc switches are based on standard Square D brand transformer connections. If these switches are used to connect to other manufacturers' transformers, then connections must match standard Square D brand transformer connections. (Cable connections are furnished with the transformer.)
in 14.75 20.00 14.75 20.00 14.75 20.00 14.75 20.00 14.75 20.00 14.75 20.00 14.75 20.00 14.75 20.00
mm 375 508 375 508 375 508 375 508 375 508 375 508 375 508 375 508
HVLCCA14505DGR HVLCCA20505DGR HVLCCA14505DGL HVLCCA20505DGL HVLCCA14515DGR HVLCCA20515DGR HVLCCA14515DGL HVLCCA20515DGL HVLCCB14505DGR HVLCCB20505DGR HVLCCB14505DGL HVLCCB20505DGL HVLCCB14515DGR HVLCCB20515DGR HVLCCB14515DGL HVLCCB20515DGL
10450E 10450E 10450E 10450E 10200E 10200E 10200E 10200E 10450E 10450E 10450E 10450E 10200E 10200E 10200E 10200E
A A A A A A A A B B B B B B B B
RH RH LH LH RH RH LH LH RH RH LH LH RH RH LH LH
54174.00 56068.00 54174.00 56068.00 57428.00 59322.00 57428.00 59322.00 54174.00 56068.00 54174.00 56068.00 57428.00 59322.00 57428.00 59322.00
Ordering Information
1. Select switch catalog number based on fused or unfused and cable entry locations (top or bottom) from Table 11.16 or Table 11.17 on page 9. 2. Select incoming line auxiliary bay from Table 11.18 or Table 11.19 on page 9, if required. 3. Select main bus from Table 11.20 on page 9, if required. 4. Select catalog numbers for factory modifications from Table 11.22 on page 9, if required. 5. If fused, select DIN/E fuses from Table 11.25.
11
SWITCHBOARDS AND SWITCHGEAR
Fuse Selection
Section Width Required $ Price
Pricing Example
Order indoor 600 A, 5 kV, HVL/cc switch with bottom incoming and bottom outgoing cables (1) #2 AWG per phase, (1) set 200E fuses, and (1) set 6 kV surge arresters.
Order: Catalog. No. Switch w/fuse provisions and HVLCCA14305D bottom exit load cables 600 incoming line auxiliary bay HVLCCA14A (Application Abottom entry) Main Bus HVLCCMBA14A14 (Application A14 in. to Application A14 in.) 6 kV LAs HVLCCDSA6 Set 200E fuses 55DE200 $ Price 19392.00 1968.00 882.00 1926.00 3326.00
in mm 55DE010 5.5 10E 1 Actual 14.75 375 954.00 55DE015 5.5 15E 1 Actual 14.75 375 954.00 55DE020 5.5 20E 1 Actual 14.75 375 954.00 55DE025 5.5 25E 1 Actual 14.75 375 954.00 55DE030 5.5 30E 1 Actual 14.75 375 1980.00 55DE040 5.5 40E 1 Actual 14.75 375 1980.00 55DE050 5.5 50E 1 Actual 14.75 375 1980.00 55DE065 5.5 65E 1 Actual 14.75 375 1980.00 55DE080 5.5 80E 1 Actual 14.75 375 1980.00 55DE100 5.5 100E 1 Actual 14.75 375 3326.00 55DE125 5.5 125E 1 Actual 14.75 375 3326.00 55DE150 5.5 150E 1 Actual 14.75 375 3326.00 55DE175 5.5 175E 1 Actual 14.75 375 3326.00 55DE200 5.5 200E 1 Actual 14.75 375 3326.00 55DE250 5.5 250E 1 Actual 14.75 375 5742.00 55DE300 5.5 300E 1 Actual 14.75 375 5742.00 55DE350 5.5 350E 1 Actual 14.75 375 5742.00 55DE400 5.5 400E 1 Actual 14.75 375 6430.00 55DE450 5.5 450E 1 Actual 14.75 375 6430.00 175DE010 15.5 10E 1 Actual 14.75 375 3214.00 175DE015 15.5 15E 1 Actual 14.75 375 3214.00 175DE020 15.5 20E 1 Actual 14.75 375 3214.00 175DE025 15.5 25E 1 Actual 14.75 375 3214.00 175DE030 15.5 30E 1 Actual 14.75 375 3290.00 175DE040 15.5 40E 1 Actual 14.75 375 3290.00 175DE050 15.5 50E 1 Actual 14.75 375 3290.00 175DE065 15.5 65E 1 Actual 14.75 375 4446.00 175DE080 15.5 80E 1 Actual 14.75 375 4446.00 4446.00 175DE100 15.5 100E 1 Actual 14.75 375 175DE125 15.5 125E 1 Actual 14.75 375 6878.00 175DE150 15.5 150E 1 Actual 14.75 375 6878.00 155DE175 15.5 175E 1 Actual 14.75 375 6878.00 155DE200 15.5 200E 1 Actual 14.75 375 6878.00 a Each (1) set of fuses contains three fuses. (E.g., (2) sets of fuses yield a total of six fuses.)
11-10
PE5A
Discount Schedule
Switchgear
www.schneider-electric.us
Fuselogic
Fuselogic is a protection system that provides the ultimate in medium voltage fuse protection. This patented system utilizes the Square D brand current-limiting fuses with mechanical sensors that function without any auxiliary power requirements. Several combinations of Fuselogic functions can be combined to provide simple blown fuse indication contacts with mechanical lockout to anti-single phasing protection. Anti-single phasing requires the optional stored energy mechanism (SEM). Fuselogic is available on both HVL/cc and HVL switches.
Side view
Front view
38.00
965
2.00
51
4.00
102 Conduit
6.36
162 908 29 .875 Mounting Hole (4 Places for .75 Anchor Bolts)
1.13
35.74
HVL 538 kV Load Interrupter is the most popular ANSI-rated switchgear in its class in America. Among medium voltage interrupter switchgear, both the switch and the enclosure stand as industry benchmarks in the areas of design, manufacturing, and performance. Load interrupter switchgear must perform a number of critical functions in a unit substation - protecting equipment and disconnecting faulted lines and transformers. Designed and tested to the latest applicable standards, HVL has been engineered to provide superior protection for your distribution system. HVL switchgear is available for various applications and configurations, including: Individual service entrance bays Multiple-bay lineups incorporatingHVL load interrupters and optional Visi/Vac circuit interrupters Substation primaries Square D brand metal-enclosed switchgear has become an industry standard for its better system performance, lower maintenance cost, easier system expansion, and reduced system expense. A full range of ratings and options are available but not listed in this publication. Contact your nearest Schneider Electric sales office or your local Schneider Electric distributor. Table 11.27:
Maximum design voltage (kV) BIL (kV) Frequency (Hz) Continuous amperes Interrupting amperes Momentary (kA asymmetrical) Fault close (kA asymmetrical) Capacitor switching (kVAR) Short time rating 2 seconds (kA symmetrical) Low frequency withstand (kV)
Ratings
4.76 60 50/60 15 95 50/60 17 95 50/60 600 600 61 40 25 36 25.8 125 50/60 29 125 50/60 38 150 50/60 600 400 40 20 25 60
600/1200 600/1200 600/1200 600/1200 40/61/80 40/61 2400 25/38/50 19 40/61/80 40/61 2400 25/38/50 36
Standard Features
11 gauge steel enclosure Direct drive mechanism Permanently attached operating handle Visible isolation viewing window Mechanical interlocked fuse access door Provision for padlock and key interlock Highly flexible design ANSI 61 paint Outdoor construction Square D brand DIN-style current-limiting fuses Boric acid fuses Silver or tin plated copper bus 600, 1200, or 2000 A main bus Heat shrink insulated bus Motor operator Shunt trip Fuselogic tripping system Automatic load transfer schemes Roof bushings Key interlocks Surge arresters Utility metering bays Line selector switch Duplex switch Transformer connections Infrared windows for thermal scanning of connections
Table 11.29:
600 A Single Switch with PROVISIONS ONLY for Square D brand CurrentLimiting, Non-Disconnect Type Fuses
kV Rating 4.76 4.76 15 15 15 15 Fuse Range 10450E 10450E 10100E 125200E 10100E 125-200E Enclosure Type NEMA 1 NEMA 3R NEMA 1 NEMA 1 NEMA 3R NEMA 3R $ Price 19392.00 21636.00 19858.00 19858.00 23978.00 23978.00
Options
Table 11.30:
600 A Single Switch with PROVISIONS ONLY for S&C Boric Acid Non-Disconnect Type Fuses
kV Rating 4.76 4.76 15 15 17 17 Fuse Range 10E400E 10E400E 10E400E 10E400E 10E400E 10E400E Enclosure Type NEMA 1 NEMA 3R NEMA 1 NEMA 3R NEMA 1 NEMA 3R $ Price 24936.00 28606.00 26650.00 30688.00 29610.00 34098.00
PE5A
Discount Schedule
11-11
11
Switchgear
Table 11.31:
Ratings
4.76 60 50/60 600 600 40,000 40,000 2,400 25,000 19 15.0 95 50/60 600 600 40,000 40,000 2,400 25,000 36
Table 11.35:
Max. Design Voltage (kV) BIL (kV) Frequency (Hz) Continuous amperes Interrupting amperes Momentary (amperes asymmetrical) Fault close (amperes asymmetrical) Capacitor switching (kVAR) Short-time rating, 2 seconds (amperes symmetrical) Low frequency withstand (kV)
600 A Duplex Switch with PROVISIONS ONLY for Square D brand Current-Limiting, Non-Disconnect Type Fuses for Cable Connection to Power-Dry II, Power-Cast II, and Uni-Cast II Transformers (FLC = 300 A max.) RHTransformer on Right, LHTransformer on Left
kV Rating Fuse Range 4.76 10450E 4.76 10450E 4.76 10450E 4.76 10450E 15 10100E 15 125200E 15 10100E 15 125200E 15 10100E 15 125200E 15 10100E 15 125-200E Enclosure Type NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 3R NEMA 3R RH / LH RH LH RH LH RH RH LH LH RH RH LH LH $ Price 42028.00 42028.00 49484.00 49484.00 43084.00 43084.00 43084.00 43084.00 54904.00 54904.00 54904.00 54904.00
Table 11.32:
System L-L Voltage kV Nominal 2.4 4.16 4.8 6.9 12.0 12.47 13.2 13.8 Maximum 2.54 4.4 5.08 7.26 12.7 13.2 13.97 14.52
Catalog No. HVL505DEGR HVL505DEGL HVL505DEWRH HVL505DEWLH HVL515DEGR1 HVL515DEGR2 HVL515DEGL1 HVL515DEGL2 HVL515DEWR1H HVL515DEWR2H HVL515DEWL1H HVL515DEWL2H
Table 11.33:
Type Indoor Outdoor
Enclosure Type
W in 38.00 38.00 mm 965 965 D H Weight in mm in mm lbs kg 54.50 1384 90.00 2286 1200 545 60.00 1524 97.50 2477 1400 636
Table 11.36:
600 A Single Switch with PROVISIONS ONLY for S&C Boric Acid Non-Disconnect Type Fuses for Cable Connection to Power-Dry II, Power-Cast II, and Uni-Cast II Transformers b (FLC = 300 A max.) RHTransformer on Right, LHTransformer on Left
HVL switches can be configured for close coupling cable connections to listed dry type transformers for primary main switches of unit substations. These are listed in the tables below with current-limiting or boric acid fuses. Both single and duplex switch mains are included in this selection. Transformers are listed on page 14-20 and may not be suitable for close coupling. For transformer availability and specific configurations, contact your local Schneider Electric sales office. All connections in this digest are based on standard Square D brand transformer connections. If these switches are used to connect to other manufacturers transformers, then connections must coordinate with standard Square D brand transformer connections. (Cable connections are furnished with the transformer.) Table 11.34: 600 A Single Switch with PROVISIONS ONLY for Square D brand Current-Limiting, Non-Disconnect Type Fuses for Cable Connection to Power-Dry II, Power-Cast II, and Uni-Cast II Transformers (FLC = 300 A max.) RHTransformer on Right, LHTransformer on Left
kV Rating Fuse Range 4.76 10450E 4.76 10450E 4.76 10450E 4.76 10450E 15 10100E 15 125200E 15 10100E 15 125200E 15 10100E 15 125-200E 15 10100E 15 125-200E Enclosure Type NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 3R NEMA 3R RH / LH RH LH RH LH RH RH LH LH RH RH LH LH $ Price 20134.00 20134.00 25322.00 25322.00 20614.00 20614.00 20614.00 20614.00 28070.00 28070.00 28070.00 28070.00
Catalog kV Enclosure RH / LH $ Price No. Rating Fuse Range Type HVL405BGR 4.76 10E400E NEMA 1 RH 25666.00 HVL405BGL 4.76 10E400E NEMA 1 LH 25666.00 HVL405BWRH 4.76 10E400E NEMA 3R RH 30674.00 HVL405BWLH 4.76 10E400E NEMA 3R LH 30674.00 HVL415BGR 15 10E400E NEMA 1 RH 27390.00 HVL415BGL 15 10E400E NEMA 1 LH 27390.00 HVL415BWRH 15 10E400E NEMA 3R RH 32476.00 HVL415BWLH 15 10E400E NEMA 3R LH 32476.00 a Includes fuse holder only. See table on page 11-14 for fuse refills.
11
SWITCHBOARDS AND SWITCHGEAR
Table 11.37:
600 A Duplex Switch with PROVISIONS ONLY for S&C Boric Acid Non-Disconnect Type Fuses for Cable Connection to Power-Dry II, Power-Cast II, and Uni-Cast II Transformers b (FLC = 300 A max.) RHTransformer on Right, LHTransformer on Left
Catalog kV Enclosure RH / LH $ Price No. Rating Fuse Range Type HVL505BGR 4.76 10E400E NEMA 1 RH 47470.00 HVL505BGL 4.76 10E400E NEMA 1 LH 47470.00 HVL505BWRH 4.76 10E400E NEMA 3R RH 57742.00 HVL505BWLH 4.76 10E400E NEMA 3R LH 57742.00 HVL515BGR 15 10E400E NEMA 1 RH 49540.00 HVL515BGL 15 10E400E NEMA 1 LH 49540.00 HVL515BWRH 15 10E400E NEMA 3R RH 60514.00 HVL515BWLH 15 10E400E NEMA 3R LH 60514.00 b Includes fuse holder only. See table on page 11-14 for fuse refills. NOTE: Switches with transformer connections are painted ANSI 49. Standalone switches are painted ANSI 61.
Catalog No. HVL405DEGR HVL405DEGL HVL405DEWRH HVL405DEWLH HVL415DEGR1 HVL415DEGR2 HVL415DEGL1 HVL415DEGL2 HVL415DEWR1H HVL415DEWR2H HVL415DEWL1H HVL415DEWL2H
11-12
PE5A
Discount Schedule
Switchgear
www.schneider-electric.us
Fuse Selection
The rule of thumb method for selecting fuses for transformer protection is 1.33 times the self-cooled full load current of the transformer or the next higher fuse rating. Selection of the fuse is the customers responsibility and should be based on transformer and system characteristics. Maximum Fuse Size: Maximum fuse size should be determined by comparing the fuse total clearing curve to the transformer damage curve. Contact Schneider Electric for transformer overload and short-circuit withstand capability. Minimum Fuse Size: Minimum fuse size shall carry the transformer magnetizing inrush current of 12 times full load amperes for 0.1 second. Table 11.38:
Catalog No. HVMB
Factory Modifications
Description $ Price 2288.00 1282.00 0.00 762.00 196.00 1618.00 1926.00 2248.00 2446.00 2836.00 3424.00
Main Bus Kit, 600 A copper Line side connector kit (main bus) 600 A with 21/0=500 MCM lugs (bottom entry only) HVLC Provisions for key interlocks (does not include key cylindersorder separately HVLX3 Auxiliary switch 2 N.O.2 N.C. contact HVLC2 Set screw type lugs 1/0500 kcmil (qty. 3) Distribution Class Surge Arresters a HVDSA3 3 kV, 2.55 MCOV HVDSA6 6 kV, 5.10 MCOV HVDSA9 9 kV, 7.65 MCOV HVDSA10 10 kV, 8.40 MCOV HVDSA12 12 kV, 10.20 MCOV HVDSA15 15 kV, 12.70 MCOV a Load side connected
Standard Features
Ordering Information
1. Select switch catalog number based on fused or unfused and enclosure type. 2. Select catalog numbers for factory modifications from the table above. 3. If fused, select fuse from table on page 11-14. 4. Price switch and fuses separately. Switches are furnished with provisions only for current-limiting fuse or boric acid fuse.
Price one (1) indoor (NEMA 1), 15 kV, 600 A switch with 80E SM-5S boric acid fuses and 10 kV distribution class surge arresters for a 7.62/13.2 kV grounded wye system.
Order: Switch with indoor enclosure Surge arrester, 10 kV Boric acid fuse (set of three, from page 11-14 Catalog No. HVL315BG HVDSA10 15SM5080 $ Price 26650.00 2446.00 1508.00
PE5A
Discount Schedule
11-13
11
Pricing Example
Switches for transformer primaries are cable connected only. Key interlocks must be ordered and coordinated by customer. Standard color is ANSI 61 for standalone units; ANSI 49 for switches connecting to transformers. If switches are purchased to coordinate with Square D brand transformers, composite drawings and shipment coordination will not be available. Switches are not designed for any special dimensions for retrofit purposes. For dimensions other than shown, contact your nearest Schneider Electric sales office or your local Schneider Electric distributor.
Switchgear
Continuous Current
5 kV Fuse 10E 17.4 51 55DE010 15E 17.4 51 55DE015 954.00 20E 17.4 51 55DE020 25E 17.4 51 55DE025 30E 17.4 51 55DE030 40E 17.4 51 55DE040 50E 17.4 51 55DE050 1980.00 65E 17.4 51 55DE065 80E 17.4 51 55DE080 100E 17.4 51 55DE100 125E 17.4 76 55DE125 150E 17.4 76 55DE150 3326.00 175E 17.4 76 55DE175 200E 17.4 76 55DE200 250E 17.4 76 55DE250 300E 17.4 76 55DE300 5742.00 350E 17.4 76 55DE350 400E 17.4 76 55DE400 6430.00 450E 17.4 76 55DE450 15 kV Fuse 10E 17.4 51 175DE010 15E 17.4 51 175DE015 3214.00 20E 17.4 51 175DE020 25E 17.4 51 175DE025 30E 17.4 51 175DE030 40E 17.4 76 175DE040 3290.00 50E 17.4 76 175DE050 65E 17.4 76 175DE065 80E 17.4 76 175DE080 4446.00 100E 17.4 88 175DE100 125E 21.14 88 175DE125 150E 21.14 88 175DE150 6878.00 175E 21.14 88 155DE175 200E 21.14 88 155DE200 a Square D brand DIN/E fuses are shown in this table. For fuses produced by other manufacturers, contact your nearest Schneider Electric sales office or your local Schneider Electric distributor. b Current-limiting fuses will increase the integrated short-circuit ratings beyond the non-fusible units. Contact your nearest Schneider Electric sales office or your local Schneider Electric distributor. c CautionThese fuses will not work for the MiniBreak. See page 11-7 for the appropriate MiniBreak fuses. d All fuses are single barrel arrangement with ferrule diameters per the chart. e Contact your Schneider Electric representative for current stock quantities. f Price includes one set of three fuses, packed in a single box.
5 kV Fuse Refill 10E SM-5S 5SM5010 RBA400 405WBAF010 15E SM-5S 5SM5015 RBA400 405WBAF015 20E SM-5S 5SM5020 RBA400 405WBAF020 25E SM-5S 5SM5025 RBA400 405WBAF025 30E SM-5S 5SM5030 RBA400 405WBAF030 40E SM-5S 5SM5040 RBA400 405WBAF040 50E SM-5S 5SM5050 1472.00 RBA400 405WBAF050 1692.00 65E SM-5S 5SM5065 RBA400 405WBAF065 80E SM-5S 5SM5080 RBA400 405WBAF080 100E SM-5S 5SM5100 RBA400 405WBAF100 125E SM-5S 5SM5125 RBA400 405WBAF125 150E SM-5S 5SM5150 RBA400 405WBAF150 175E SM-5S 5SM5175 200E SM-5S 5SM5200 RBA400 405WBAF200 250E SM-5S 5SM5250 1528.00 RBA400 405WBAF250 1758.00 300E SM-5S 5SM5300 RBA400 405WBAF300 400E SM-5S 5SM5400 RBA400 405WBAF400 15 kV Fuse Refill 10E SM-5S 15SM5010 RBA400 415WBAF010 15E SM-5S 15SM5015 RBA400 415WBAF015 20E SM-5S 15SM5020 RBA400 415WBAF020 RBA400 415WBAF025 25E SM-5S 15SM5025 30E SM-5S 15SM5030 RBA400 415WBAF030 40E SM-5S 15SM5040 RBA400 415WBAF040 50E SM-5S 15SM5050 1508.00 RBA400 415WBAF050 1732.00 65E SM-5S 15SM5065 RBA400 415WBAF065 80E SM-5S 15SM5080 RBA400 415WBAF080 100E SM-5S 15SM5100 RBA400 415WBAF100 125E SM-5S 15SM5125 RBA400 415WBAF125 150E SM-5S 15SM5150 RBA400 415WBAF150 175E SM-5S 15SM5175 200E SM-5S 15SM5200 RBA400 415WBAF200 250E SM-5S 15SM5250 1554.00 RBA400 415WBAF250 1788.00 300E SM-5S 15SM5300 RBA400 415WBAF300 400E SM-5S 15SM5400 RBA400 415WBAF400 g S&C Boric Acid Fuses Type SM-5S fuses are manufactured by the S&C Electric Company. SM-5S has a 25.0 kA symmetrical short-circuit rating from 2.4 kV to 17.0 kV. For 16.5 kV ratings, only S&C boric acid fuses can be used. h Cutler-Hammer - Westinghouse Fuses Type RBA-400 fuses are manufactured by Cutler-Hammer EATON Corporation. RBA-400 has a 37.5 kA symmetrical ampere short-circuit rating from 2.4 kV to 4.8 kV and 29.4 kA symmetrical from 12 kV to 13.8 kV. i CautionThese fuses will not work for the MiniBreak. See page 11-7 for the appropriate MiniBreak fuses. j Contact your Schneider Electric representative for current stock quantities. k Price includes one set of three fuses, packed in a single box.
11
SWITCHBOARDS AND SWITCHGEAR
11-14
PE5A
Discount Schedule
Switchgear
www.schneider-electric.us
Ratings
4.16 4.76 60 50/60 12003000 250350 36 49 97 132 7.2 8.25 95 50/60 12003000 500 41 111 13.8 15.0 95 50/60 12003000 5007501000 23 36 48 62 97 130 24.9 27.0 125 50/60 12002000 12502000 25 40 68 108
Nominal voltage (kV) Maximum voltage (kV) BIL (kV) Frequency (Hz) Continuous amperes (A) MVA (reference only) Short-time rating (kA) 3 seconds Close and latch rating (kA) (peak)
Switchgear Construction
Floor mounted breaker racking mechanism Standard epoxy supports or optional porcelain supports Aluminum or copper main bus Indoor NEMA 1 Outdoor NEMA 3R Walk-in Non walk-in
Active system detects and controls the effects of internal arcing faults. It complies with ANSI C37.20.7 requirements for arc resistant switchgear for Type 1, Type 2, and Type 2A.
Benefits
Prevents pressure buildup Reduces release of toxic materials Eliminates need for reinforced switchgear Elimnates special requirements for buildings or plenums Minimizes equipment damage Reduces operating downtime
11-15
11
Unit Substation
Primary Section Medium voltage load interrupter switchgear Metalclad switchgear Low voltage Power-Style QED switchboard Air terminal chamber Transformer Section Open, ventilated dryPower-Dry Open, ventilated dry/cast resin combinationUni-Cast Open, ventilated cast resinPower-Cast Mineral oil or high fire point fluidliquid Secondary Section Medium voltage load interrupter switchgear Metalclad switchgear Medium voltage motor control center Low voltage Power-Style QED switchboard Air terminal chamber Low voltage drawout switchgear Low voltage Model 6 motor control centers
11-1
14-1
11-1
17-1
11
SWITCHBOARDS AND SWITCHGEAR Model III Shown with HVL/cc Load Interrupter Switch
11-16
Unit Substations
www.schneider-electric.us
Transformer Section
Special barrel wound dry-type transformers employing resin encapsulated VPI (Vacuum Pressure Impregnation) techniques are used to achieve the low-loss, compact design necessary for the space-saving package substation concept. Class H, 220C insulation is used throughout. Temperature rise is 150C as standard, although 80C or 115C low temperature premium transformers are available through 750 kVA. Aluminum windings are standard with copper as an option. Four full capacity 2-1/2 percent taps are provided-two above nominal voltage and two below. Fan cooling is optional. When selected, it increases the capacity rating of the transformer an additional 33 percent. The Model 98 digital controller is employed. This system provides precision control through the use of three high accuracy thermocouple type sensorsone in each phase of the windings. The controller has a membrane front panel for displaying the temperature of all three phases with individual readings. The hottest phase is automatically displayed. The Model 98 features simple three-button operation with fan, alarm and trip function settings and is Powerlogic compatible. Table 11.44:
KV Class 1.2 2.5 5.0 7.2 8.7 15.0
Distribution Section
I-Line Mounted Molded Case Circuit Breakers
8.25 5.50
140 210
5.00
127
31.40
798
22.00
559
2.00
51
10.46
266
40
2.00 51.63
16
13.50
5.45
138
FA,FH,FY HD,HG HJ, HL QB, QD QG, QJ FI, KI, JD JG, JJ, JL Q4, LA, LH LC, LI, LX LXI, LE MG, MJ
28.25
718
6.00
152
36.00
914
85.06
2161
14.75
375
203
203
4.00
102
SN
79.85
2028
HCR-U
Table 11.45:
kVA 75 112.5 150 225 300 500 500 750 1000
14.75
375
Lifting Jacks
Front View
Contact your nearest Schneider Electric sales office for pricing assistance.
11-17
11
8.00 8.00
2.00 1.56
51
Molded case circuit breakers are group mounted in an I-Line panelboard section offering the inherent ease of installation for which the plug-on I-Line circuit breaker has become known. All circuit breakers are quick-make, quick-break, thermal magnetic, permanent trip type and are factory-calibrated and sealed for accurate overcurrent response and maximum short-circuit strength. PowerPact P and R circuit breakers are available with solid-state Micrologic trip units. Current limiting high interrupting capacity FI, KI, and LI circuit breakers are also available. Circuit breakers may be safely back-fed for use as main circuit breakers. All circuit breakers are UL listed and carry integrated equipment rating when used exclusively with other Square D brand circuit breakers in intended assemblies. I-Line panel is available in 1200 A. Maximum mounting space is 108 inches. Tin-plated copper bus is standard. HCR-U 1200 A I-Line panelboards can be used for up to 600 Vac. They are Underwriters Laboratories (UL) Listed under File E33139.
6.00
152
11
SWITCHBOARDS AND SWITCHGEAR
Voltage1538 kV 110200 kV BIL Ampere Ratings600, 800, 1200, 2000, 3000, 3500, and 4000 Interrupting amperes12.540 kA (rms symmetrical) Arc resistant enclosure construction, 2000 A and below, based on EEMAC and IEC test standards No fans required for 3000 A ratings Interrupting time of three (3) cycles Hermetically sealed vacuum interrupters
The arc-resistant design takes safety to the next level. In the event of an arc, the arc-resistant construction provides increased safety for personnel working in proximity of the breaker by venting resultant arc by-products and ionized gases upward and away from exterior panels that otherwise may not remain intact and in place. The Powersub circuit breakers also provide superior protection as a result of their high speed operation. You can expect long life from the product as the vacuum interrupter contacts are protected from corroding elements and contamination.
11-18
Table of Contents
Section 12
Busway
Powerbus 225 Busway
225 Ampere240 Volt 100 Ampere600 Volt Powerbus Plug-In Units 12-2 12-2 12-3
I-Line Busway Standard Components I-Line II Busway Standard Components I-Line II Pricing Instructions Accessories Plug-In Units (Fusible and Circuit Breaker Types) H- and J-Frame Circuit Breakers 80% and 100% Rated R-Frame Circuit Breakers 80% and 100% Rated Plug-In Units (Specialty Types)
12-4 12-5 12-6, 12-7 12-8 12-9, 12-10 12-11 12-12 12-13
Power-Zone Busway
Non-Segregated Busway Footage and Fittings Options and Accessories 12-14, 12-15, 12-16 12-15 12-16
Missing Link program guarantees shipment in a maximum of 5 working days of a small quantity of indoor feeder straight lengths and fittings. Orders for outdoor busway or for international destinations may require 2 extra days for processing. Measurement Services are offered for your critical and complex projects. Schneider Electric
will assist with field measurement and assume responsibility for the layout and exact fit of all components. Contact your local Schneider Electric sales office for exact details.
Emergency Service; we are on call 24 hours a day, 7 days a week, 365 days a year. For
emergencies, call 1-888-SquareD (1-888-778-2733).
Quick Ship program provides product availability for time sensitive orders. The program is available through the product selectors and offers a limited selection of I-Line busway footage and fittings. Contact your local Schneider Electric sales office for exact details.
New!
12-1
12
BUSWAY
Powerbus 225 construction consists of a light-weight electrical grade all-aluminum housing with silver-plated copper conductor bars for maximum electrical efficiency. The total product offering includes straight sections, fittings, accessories, and plug-in units for a total installation. This new busway is available in two power ratings: 225 A (240 V) and 100 A (600 V).
G
Component
L2 N L3
IG L2 N
Straight 10 ft. Straight 4 ft. Elbow Left Elbow Right Cross Fitting Tap Box
12W Isolated Ground Catalog No. $ Price PBCP3B100ST120 1378.00 PBCP3B100ST048 770.00 PBCF3B100LL 1304.00 PBCF3B100LR 1304.00 PBCF3B100CR 1534.00 PBCF3B100TB 1512.00
Table 12.6:
G
Component
L2 N L3
IG L2 N
G L1 L2 L3
Straight 10 ft. Straight 4 ft. Elbow Left Elbow Right Cross Fitting Tap Box
12W Isolated Ground Catalog No. $ Price PBCP3B225ST120 2608.00 PBCP3B225ST048 1044.00 PBCF3B225LL 1964.00 PBCF3B225LR 1964.00 PBCF3B225CR 2980.00 PBCF3B225TB 2070.00
G L1 IG L2 L3
Table 12.2:
Straight 10 ft. Straight 4 ft. Elbow Left Elbow Right Cross Fitting Tap Box
33W Isolated Ground Catalog No. PBCP4B100ST120 PBCP4B100ST048 PBCF4B100LL PBCF4B100LR PBCF4B100CR PBCF4B100TB
Table 12.7:
G L1
Component
L2 L3
33W Catalog No. PBCP3A225ST120 PBCP3A225ST048 PBCF3A225LL PBCF3A225LR PBCF3A225CR PBCF3A225TB
G L1 IG L2 L3
G L1 L2 N L3
Straight 10 ft. Straight 4 ft. Elbow Left Elbow Right Cross Fitting Tap Box
33W Isolated Ground Catalog No. $ Price PBCP4B225ST120 3232.00 PBCP4B225ST048 1292.00 PBCF4B225LL 2410.00 PBCF4B225LR 2410.00 PBCF4B225CR 2980.00 PBCF4B225TB 2070.00
Table 12.3:
Straight 10 ft. Straight 4 ft. Elbow Left Elbow Right Cross Fitting Tap Box
34W 100% Neutral Catalog No. $ Price PBCP4A100ST120 1654.00 PBCP4A100ST048 968.00 PBCF4A100LL 1366.00 PBCF4A100LR 1366.00 PBCF4A100CR 1620.00 PBCF4A100TB 1662.00
G L1 50% IG or N L2 Integral N Ground L3 34W100% Neutral plus Isolated Ground; or 200% Neutral Catalog No. $ Price PBCP5A100ST120 2072.00 PBCP5A100ST048 1072.00 PBCF5A100LL 2172.00 PBCF5A100LR 2172.00 PBCF5A100CR 1944.00 PBCF5A100TB 1962.00
Table 12.8:
Description Catalog No. $ Price
100 A Accessories
Hanger PB100FH 50.00 End Closure PB100EC 120.00 Wall Flange PB100WF 140.00 Plug-in Opening Cover PBPIOCVR 60.00
G L1
Component
L2 N L3
Straight 10 ft. Straight 4 ft. Elbow Left Elbow Right Cross Fitting Tap Box
34W 100% Neutral Catalog No. PBCP4A225ST120 PBCP4A225ST048 PBCF4A225LL PBCF4A225LR PBCF4A225CR PBCF4A225TB
G L1 50% IG or N L2 Integral N Ground L3 34W100% Neutral plus Isolated Ground; or 200% Neutral Catalog No. $ Price PBCP5A225ST120 4232.00 PBCP5A225ST048 2200.00 PBCF5A225LL 3840.00 PBCF5A225LR 3840.00 PBCF5A225CR 6408.00 PBCF5A225TB 4120.00
12
BUSWAY
Table 12.4:
Description Catalog No. $ Price
225 A Accessories
Hanger PB225FH 80.00 End Closure PB225EC 226.00 Wall Flange PB225WF 196.00 Plug-in Opening Cover PBPIOCVR 60.00
12-2
PE8
Discount Schedule
Plug-In Units
Class 5600 / Refer to Catalog 5600CT0201 with ingress/dust and moisture protection of IP40. An optional kit is available for FA and QO units to raise the protection to IP54. This kit will also raise the QOR unit to moisture protection of IPX3.
Powerbus plug-in units are rated maximum 100 ampere. The basic unit is a tap box rated IP54 Standard; three other styles are offered with provisions to accept various circuit breakers and receptacles. All units are supplied Table 12.9:
Busbar Configuration
3E
G IG L2 N 50% Integral Ground
Tap Box FA Unit Catalog Number $ Price Catalog Number $ Price PBPTB3E100 614.00 3 Phase systems only N/A PBPTB3B100 614.00 N/A PBPTB3A100 614.00 PBPFA3A100 832.00 PBPTB4B100 670.00 PBPFA4B100 870.00 PBPTB4A100 670.00 PBPFA4A100 870.00 PBPTB5A100 782.00 PBPFA5A100 946.00 See bottom of page for receptacles which can be field-installed in this unit.
QOR Unit Catalog Number PBPQOR3E100 PBPQOR3B100 PBPQOR3A100 PBPQOR4B100 PBPQOR4A100 PBPQOR5A100
3A
G L1 IG L2 L3
Table 12.10:
50% Integral Ground
Accessories
Catalog Number PBFO100FA PBFO100QO PBRFLKIT $ Price 144.00 144.00 60.00
Table 12.11:
Description FA Unit QO Unit
Description Floor OperatorFA Unit Floor OperatorQO Unit Reverse Feed Kit for FA Unit
4B
G L1 L2 N L3
Table 12.12:
50% Integral Ground
4A
G L1 IG or N L2 N L3
5A
Circuit 3A Configuration 4B Configuration Breaker Catalog Number $ Price Catalog Number Rating 15 PBPFA3A100A015 1780.00 PBPFA4B100A015 20 PBPFA3A100A020 1780.00 PBPFA4B100A020 30 PBPFA3A100A030 1780.00 PBPFA4B100A030 40 PBPFA3A100A040 1780.00 PBPFA4B100A040 50 PBPFA3A100A050 1780.00 PBPFA4B100A050 60 PBPFA3A100A060 1780.00 PBPFA4B100A060 70 PBPFA3A100A070 1912.00 PBPFA4B100A070 80 PBPFA3A100A080 1912.00 PBPFA4B100A080 90 PBPFA3A100A090 1912.00 PBPFA4B100A090 100 PBPFA3A100A100 1912.00 PBPFA4B100A100 Note: See Digest Section 7 for FA circuit breaker information.
L1 L2 L3
Table 12.13:
1-pole QO/QOB circuit breakers with NEMA 5-15R or 5-20R receptaclesb Circuit 3E Configuration 4A Configuration 5A Configuration Breaker Rating Type Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price Type 1 (3 circuit breakers w. 3 duplex recep.) (3 circuit breakers w. 3 duplex recep.) 3E configuration places a circuit breaker in 15 QO the middle and bottom slot in the front cover of PBPQOR4A100M115 850.00 PBPQOR5A100M115 950.00 15 QOB the unit and a receptacle in the center and right PBPQOR4A100M115B 886.00 PBPQOR5A100M115B 986.00 positions in the base of the unit. 20 QO PBPQOR4A100M120 850.00 PBPQOR5A100M120 950.00 (See below for 2 duplex receptacles. 20 QOB PBPQOR4A100M120B 886.00 PBPQOR5A100M120B 986.00 Type 2 (2 circuit breakers w. 2 duplex recep.) (3 circuit breakers w. 2 duplex/1 locking) (3 circuit breakers w. 2 duplex/1 locking) 15 QO PBPQOR3E100M215 772.00 PBPQOR4A100M215 862.00 PBPQOR5A100M215 962.00 15 QOB PBPQOR3E100M215B 796.00 PBPQOR4A100M215B 898.00 PBPQOR5A100M215B 998.00 20 QO PBPQOR3E100M220 772.00 PBPQOR4A100M220 862.00 PBPQOR5A100M220 962.00 20 QOB PBPQOR3E100M220B 796.00 PBPQOR4A100M220B 898.00 PBPQOR5A100M220B 998.00 Type 3 (2 circuit breakers w. 1 duplex/1 locking) (3 circuit breakers w. 1 duplex/2 locking) (3 circuit breakers w. 1 duplex/2 locking) 15 QO PBPQOR3E100M315 784.00 PBPQOR4A100M315 874.00 PBPQOR5A100M315 974.00 15 QOB PBPQOR3E100M315B 808.00 PBPQOR4A100M315B 910.00 PBPQOR5A100M315B 1010.00 20 QO PBPQOR3E100M320 784.00 PBPQOR4A100M320 874.00 PBPQOR5A100M320 974.00 20 QOB PBPQOR3E100M320B 808.00 PBPQOR4A100M320B 910.00 PBPQOR5A100M320B 1010.00 Type 4 (2 circuit breakers w. 2 locking recep.) (3 circuit breakers w. 3 locking recep.) (3 circuit breakers w. 3 locking recep.) 15 QO PBPQOR3E100M415 796.00 PBPQOR4A100M415 886.00 PBPQOR5A100M415 986.00 15 QOB PBPQOR3E100M415B 820.00 PBPQOR4A100M415B 922.00 PBPQOR5A100M415B 1022.00 20 QO PBPQOR3E100M420 796.00 PBPQOR4A100M420 886.00 PBPQOR5A100M420 986.00 20 QOB PBPQOR3E100M420B 820.00 PBPQOR4A100M420B 922.00 PBPQOR5A100M420B 1022.00 b Many more factory assembled units are available using combinations of 1P/2P/3P circuit breakers with other receptacles shown below. Consult your nearest Schneider Electric sales office. Note: See Digest Section 7 for QO/QOB circuit breaker information. Other available QO circuit breakers include -GFI, -HID, -K, and -EPD types. Note: Plug-in units have 1.82" x 2.82" openings for receptacle bodies and 3.28" spacing between #6-32 mounting holes.
Type 1 L1 L2 L3
Type 2 L1 L2 L3
Type 3 L1 L2 L3
Table 12.14:
Non-Locking Devices
Voltage 120 240 120 240 120 / 240 3 240 120 / 240 3 240 15 A 1-15R 5-15R 6-15R 11-15R 14-15R 15-15R 20 A 2-20R 5-20R 6-20R 10-20R 11-20R 14-20R 15-20R
Table 12.15:
Locking Devices
Voltage 120 240 120 240 120 / 240 3 240 120 / 240 3 240 3Y 120/208 3Y 120/208 15 A L1-15R L5-15R L6-15R L11-15R 20 A L2-20R L5-20R L6-20R L10-20R L11-20R L14-20R L15-20R L18-20R L21-20R 30 A L5-30R L6-30R L10-30R L11-30R L14-30R L15-30R L18-30R L21-30R
Acceptable NEMA Receptacles Wiring 2-pole, 2-wire 2-pole, 2-wire 2-pole, 3-wire grounding 2-pole, 3-wire grounding 3-pole, 3-wire 3-pole, 3-wire 3-pole, 3-wire grounding 3-pole, 3-wire grounding
Acceptable NEMA Receptacles Wiring 2-pole, 2-wire 2-pole, 2-wire 2-pole, 3-wire grounding 2-pole, 3-wire grounding 3-pole, 3-wire 3-pole, 3-wire 3-pole, 4-wire grounding 3-pole, 4-wire grounding 4-pole, 4-wire 4-pole, 5-wire grounding
Type 4
PE8
Discount Schedule
12-3
12
BUSWAY
I-Line Busway
Standard Components
Class 5600 / Refer to Catalog 5600CT0201
www.schneider-electric.us
Table 12.16:
Aluminum
Front 10'-0"
G PH PH PH N $ Price 1900.00 2320.00 2920.00 2320.00 2920.00 3980.00 2520.00 2940.00 3580.00 2940.00 3540.00 4640.00
G PH PH PH N
1'-6" Front
Top 1'-6"
G PH PH PH N
1'-6" 1'-6"
Front
G PH PH PH N $ Price 2048.00 2174.00 2354.00 2496.00 2676.00 2994.00 2234.00 2360.00 2552.00 2682.00 2862.00 3192.00
Top
1'-3" 10"
G PH PH PH N Plug-In Tap Box Catalog No. PTB302G PBTB306G PBTB306G PTB502G PBTB506G PBTB506G PTB302G PBTB306G PBTB306G PTB502G PBTB506G PBTB506G
G PH PH PH N $ Price 2134.00 4036.00 4036.00 2588.00 4566.00 4566.00 2134.00 4036.00 4036.00 2588.00 4566.00 4566.00
Number of Poles and Voltage 33W 34W 33W + Integral Ground Bus 34W + Integral Ground Bus
Rating (A) 225 400 600 225 400 600 225 400 600 225 400 600
10'-0" Length Catalog No. AP30210 AP30410 AP30610 AP50210 AP50410 AP50610 AP302G10 AP304G10 AP306G10 AP502G10 AP504G10 AP506G10
6'-0" Length Catalog No. AP3026 AP3046 AP3066 AP5026 AP5046 AP5066 AP302G6 AP304G6 AP306G6 AP502G6 AP504G6 AP506G6 $ Price 1140.00 1392.00 1752.00 1392.00 1752.00 2388.00 1512.00 1764.00 2148.00 1764.00 2124.00 2784.00
Front Elbowa Catalog No. AP302LF( ) AP304LF( ) AP306LF( ) AP502LF( ) AP504LF( ) AP506LF( ) AP302GLF( ) AP304GLF( ) AP306GLF( ) AP502GLF( ) AP504GLF( ) AP506GLF( ) $ Price 2048.00 2174.00 2354.00 2496.00 2676.00 2994.00 2234.00 2360.00 2552.00 2682.00 2862.00 3192.00
Top Elbowa Catalog No. AP302LT( ) AP304LT( ) AP306LT( ) AP502LT( ) AP504LT( ) AP506LT( ) AP302GLT( ) AP304GLT( ) AP306GLT( ) AP502GLT( ) AP504GLT( ) AP506GLT( )
Plug-In Tee Catalog No. PTT23WG PTT33WG PTT43WG PTT24WG PTT34WG PTT44WG PTT23WG PTT33WG PTT43WG PTT24WG PTT34WG PTT44WG $ Price 3060.00 3060.00 3060.00 3726.00 3726.00 3726.00 3060.00 3060.00 3060.00 3726.00 3726.00 3726.00
Table 12.17:
Copper
Front
G PH PH PH N
G PH PH PH N
1'-6" Front
Top 1'-6"
G PH PH PH N
1'-6" 1'-6"
Front
G PH PH PH N $ Price 2162.00 2516.00 2816.00 2718.00 3324.00 3534.00 2456.00 2810.00 3122.00 3012.00 3618.00 3840.00
Top
1'-3" 10"
G PH PH PH N Plug-In Tap Box Catalog No. PTB302G PBTB306G PBTB306G PTB502G PBTB506G PBTB506G PTB302G PBTB306G PBTB306G PTB502G PBTB506G PBTB506G
G PH PH PH N $ Price 2134.00 4036.00 4036.00 2588.00 4566.00 4566.00 2134.00 4036.00 4036.00 2588.00 4566.00 4566.00
Rating (A)
6'-0" Length Catalog No. CP3026 CP3046 CP3066 CP5026 CP5046 CP5066 CP302G6 CP304G6 CP306G6 CP502G6 CP504G6 CP506G6 $ Price 1368.00 2076.00 2676.00 1836.00 3048.00 3468.00 1956.00 2664.00 3288.00 2424.00 3636.00 4080.00
Front Elbowa Catalog No. CP302LF ( ) CP304LF ( ) CP306LF ( ) CP502LF ( ) CP504LF ( ) CP506LF ( ) CP302GLF ( ) CP304GLF ( ) CP306GLF ( ) CP502GLF ( ) CP504GLF ( ) CP506GLF ( ) $ Price 2162.00 2516.00 2816.00 2718.00 3324.00 3468.00 2456.00 2810.00 3122.00 3012.00 3618.00 3840.00
Top Elbowa Catalog No. CP302LT( ) CP304LT( ) CP306LT( ) CP502LT( ) CP504LT( ) CP506LT( ) CP302GLT( ) CP304GLT( ) CP306GLT( ) CP502GLT( ) CP504GLT( ) CP506GLT( )
Plug-In Tee Catalog No. PTT23WG PTT33WG PTT33WG PTT24WG PTT34WG PTT34WG PTT23WG PTT33WG PTT33WG PTT24WG PTT34WG PTT34WG $ Price 3060.00 3060.00 3060.00 3726.00 3726.00 3726.00 3060.00 3060.00 3060.00 3726.00 3726.00 3726.00
225 CP30210 2280.00 33W 400 CP30410 3460.00 600 CP30610 4460.00 225 CP50210 3060.00 34W 400 CP50410 5080.00 600 CP50610 5780.00 33W 225 CP302G10 3260.00 + Integral Ground 400 CP304G10 4440.00 Bus 600 CP306G10 5480.00 CP502G10 4040.00 34W 225 400 CP504G10 6060.00 + Integral Ground 600 CP506G10 6800.00 Bus a Add I for inside elbow; add O for outside elbow.
Table 12.18:
Common Accessories
Ampere Rating Hanger End Closure Wall Flange Floor Flange Aluminum Copper Flatwise Vertical Edgewise $ Price Seismica $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price 225 225 HP2F HP2V HP3E 64.00 HP2SH 96.00 ACP2EC 446.00 ACP2WF 418.00 ACP2FF 418.00 400 400 HP3F HP3V HP3E 64.00 HP3SH 96.00 ACP3EC 446.00 ACP3WF 418.00 ACP3FF 418.00 600 HP3F HP3V HP3E 64.00 HP3SH 96.00 ACP3EC 446.00 ACP3WF 418.00 ACP3FF 418.00 600 HP5F HP4V HP5E 64.00 HP5SH 96.00 ACP4EC 446.00 ACP4WF 418.00 ACP4FF 418.00 a For seismic applications, seismic hangers must be used with horizontal mount flatwise or edgewise busway. Vertical mount busway may use standard fixed or spring hangers.
Table 12.20:
Fittings
Ampere Rating 225 400 600 225 400 600 Flanged End Elbow Right Angle Tap Box Tee Unfused Reducer Adapter Expansion Cubicle Fitting C/B or Fus. $ Price $ Price Labor Only Each 2486.00 10432.00 2800.00 12312.00 3038.00 18298.00 2936.00 10882.00 3186.00 12700.00 3634.00 18890.00 End Closures $ Price Each 446.00 446.00 446.00 446.00 446.00 446.00 Fire Barriers $ Price Each 764.00 764.00 764.00 764.00 764.00 764.00
12
BUSWAY
$ Price $ Price $ Price $ Price $ Price Labor Only Labor Only Labor Only Labor Only Labor Only 954.00 1478.00 2134.00 1800.00 1098.00 1478.00 4036.00 1800.00 930.00 1408.00 1478.00 4036.00 1800.00 1024.00 982.00 1800.00 2588.00 2098.00 1128.00 1800.00 4566.00 2098.00 1288.00 1454.00 1800.00 4566.00 2098.00 1404.00
12-4
PE8
Discount Schedule
I-Line II Busway
www.schneider-electric.us
Table 12.21:
Top
10'0"
10'0"
G PH PH PH N
G G PH PH PH N N
10'0"
G PH PH PH N
Top
G PH PH PH N
10'0" Length Feeder Stylea Plug-In Styleb Catalog No. $ Price Catalog No. $ Price 800 AF2308G10ST 3940.00 AP2308G10ST 3940.00 1000 AF2310G10ST 4400.00 AP2310G10ST 4400.00 1200 AF2312G10ST 5920.00 AP2312G10ST 5920.00 1350 AF2313G10ST 6820.00 AP2313G10ST 6820.00 33W 1600 AF2316G10ST 8380.00 AP2316G10ST 8380.00 + Integral 2000 AF2320G10ST 10040.00 AP2320G10ST 10040.00 Ground Bus 2500 AF2325G10ST 12220.00 AP2325G10ST 12220.00 3000 AF2330G10ST 13980.00 AP2330G10ST 13980.00 4000 AF2340G10ST 19120.00 AP2340G10ST 19120.00 5000 800 AF2508G10ST 4780.00 AP2508G10ST 4780.00 1000 AF2510G10ST 5780.00 AP2510G10ST 5780.00 1200 AF2512G10ST 7220.00 AP2512G10ST 7220.00 1350 AF2513G10ST 8260.00 AP2513G10ST 8260.00 34W 1600 AF2516G10ST 10000.00 AP2516G10ST 10000.00 + Integral 2000 AF2520G10ST 12220.00 AP2520G10ST 12220.00 Ground Bus 2500 AF2525G10ST 15000.00 AP2525G10ST 15000.00 3000 AF2530G10ST 17440.00 AP2530G10ST 17440.00 4000 AF2540G10ST 23420.00 AP2540G10ST 23420.00 5000 a Feeder style also available in lengths from 16 to 119 inches. b Plug-in style also available in 4, 6, and 8 foot lengths. c Add (H) or (V) to catalog number based on horizontal or vertical mounting arrangement. d Cannot be used for 800 A copper busway. Number of Poles Amp Rating
) ) )
PTB516G ( )
10'0" Length Feeder Stylea Plug-In Styleb Catalog No. $ Price Catalog No. $ Price CF2308G10ST 6440.00 CP2308G10ST 6440.00 CF2310G10ST 6820.00 CP2310G10ST 6820.00 CF2312G10ST 8840.00 CP2312G10ST 8840.00 CF2313G10ST 10320.00 CP2313G10ST 10320.00 CF2316G10ST 11860.00 CP2316G10ST 11860.00 CF2320G10ST 15140.00 CP2320G10ST 15140.00 CF2325G10ST 19220.00 CP2325G10ST 19220.00 CF2330G10ST 22880.00 CP2330G10ST 22880.00 CF2340G10ST 29600.00 CP2340G10ST 29600.00 CF2350G10ST 35700.00 CP2350G10ST 35700.00 CF2508G10ST 8340.00 CP2508G10ST 8340.00 CF2510G10ST 9860.00 CP2510G10ST 9860.00 CF2512G10ST 11800.00 CP2512G10ST 11800.00 CF2513G10ST 13180.00 CP2513G10ST 13180.00 CF2516G10ST 15940.00 CP2516G10ST 15940.00 CF2520G10ST 19620.00 CP2520G10ST 19620.00 CF2525G10ST 24040.00 CP2525G10ST 24040.00 CF2530G10ST 30620.00 CP2530G10ST 30620.00 CF2540G10ST 38720.00 CP2540G10ST 38720.00 CF2550G10ST 46900.00 CP2550G10ST 46900.00
Table 12.22:
Number of Poles
Amp Rating 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 800 1000 1200 1350 1600 2000 2500 3000 4000 5000
End Tap Box Catalog No. $ Price AF2308GETBMB 4744.00 AF2310GETBMB 4919.00 AF2312GETBMB 5253.00 AF2313GETBMB 5444.00 AF2316GETBMB 5786.00 AF2320GETBMB 6257.00 AF2325GETBMB 7430.00 AF2330GETBMB 8003.00 AF2340GETBMB 9371.00 AF2508GETBMB 5408.00 AF2510GETBMB 5712.00 AF2512GETBMB 6052.00 AF2513GETBMB 6286.00 AF2516GETBMB 6679.00 AF2520GETBMB 7412.00 AF2525GETBMB 9006.00 AF2530GETBMB 9921.00 AF2540GETBMB 11628.00
Edgewise Elbow Catalog No. $ Price AF2308GLEM11 2186.00 AF2310GLEM11 2271.00 AF2312GLEM11 3051.00 AF2313GLEM11 3216.00 AF2316GLEM11 3502.00 AF2320GLEM11 3807.00 AF2325GLEM11 4206.00 AF2330GLEM11 4529.00 AF2340GLEM11 5983.00 AF2508GLEM11 2668.00 AF2510GLEM11 2852.00 AF2512GLEM11 3802.00 AF2513GLEM11 3992.00 AF2516GLEM11 4311.00 AF2520GLEM11 4718.00 AF2525GLEM11 5228.00 AF2530GLEM11 5675.00 AF2540GLEM11 7212.00
Flatwise Elbow Catalog No. $ Price AF2308GLFM11 2186.00 AF2310GLFM12 2344.00 AF2312GLFM12 3150.00 AF2313GLFM13 3444.00 AF2316GLFM13 3782.00 AF2320GLFM15 4476.00 AF2325GLFM17 5428.00 AF2330GLFM18 6160.00 AF2340GLFM22 9489.00 AF2508GLFM11 2668.00 AF2510GLFM12 2948.00 AF2512GLFM12 3922.00 AF2513GLFM13 4268.00 AF2516GLFM13 4645.00 AF2520GLFM15 5533.00 AF2525GLFM17 6728.00 AF2530GLFM18 7710.00 AF2540GLFM22 11505.00
End Tap Box Catalog No. $ Price CF2308GETBMB 4953.00 CF2310GETBMB 5120.00 CF2312GETBMB 5497.00 CF2313GETBMB 5736.00 CF2316GETBMB 6076.00 CF2320GETBMB 6682.00 CF2325GETBMB 8014.00 CF2330GETBMB 8745.00 CF2340GETBMB 10260.00 CF2350GETBMB 12869.00 CF2508GETBMB 5705.00 CF2510GETBMB 6052.00 CF2512GETBMB 6433.00 CF2513GETBMB 6696.00 CF2516GETBMB 7174.00 CF2520GETBMB 8029.00 CF2525GETBMB 9759.00 CF2530GETBMB 11020.00 CF2540GETBMB 12903.00 CF2550GETBMB 14952.00
Edgewise Elbow Catalog No. $ Price CF2308GLEM11 2645.00 CF2310GLEM11 2714.00 CF2312GLEM11 3587.00 CF2313GLEM11 3858.00 CF2316GLEM11 4140.00 CF2320GLEM11 4742.00 CF2325GLEM11 5490.00 CF2330GLEM11 6161.00 CF2340GLEM11 7938.00 CF2350GLEM11 9023.00 CF2508GLEM11 3321.00 CF2510GLEM11 3600.00 CF2512GLEM11 4641.00 CF2513GLEM11 4894.00 CF2516GLEM11 5400.00 CF2520GLEM11 6075.00 CF2525GLEM11 6885.00 CF2530GLEM11 8092.00 CF2540GLEM11 10017.00 CF2550GLEM11 11516.00
Flatters Elbow Catalog No. $ Price CF2308GLFM11 2645.00 CF2310GLFM11 2714.00 CF2312GLFM12 3734.00 CF2313GLFM12 4030.00 CF2316GLFM12 4338.00 CF2320GLFM13 5246.00 CF2325GLFM15 6771.00 CF2330GLFM16 8067.00 CF2340GLFM21 12901.00 CF2350GLFM21 14973.00 CF2508GLFM11 3321.00 CF2510GLFM11 3600.00 CF2512GLFM12 4838.00 CF2513GLFM12 5114.00 CF2516GLFM12 5666.00 CF2520GLFM13 6729.00 CF2525GLFM15 8488.00 CF2530GLFM16 10643.00 CF2540GLFM21 16470.00 CF2550GLFM21 19333.00
Table 12.23:
Ampere Rating Al Cu 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 a
Accessories
Horizontal Mount Busway Flatwise Edgewise HF38F HF43E HF43F HF43E HF53F HF58E HF58F HF58E HF63F HF67E HF67F HF67E HF73F HF78E HF78F HF78E HF88F HF88E HF13F HF13E HF15F HF15E HF16F HF16E HF19F HF19E HF25F HF26E HF26F HF26E HF24F HF24E HF25F HF26E Hangers Vertical Mount Busway Fixed Spring HFV HFV HFV HFV HFV HFV HFV HFV See Table 12.26 on HFV page 12-8 HFV HFV HFV HFV HFV HFV HFV HFV End Closure $ Price 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 64.00 Seismica HF38SH HF43SH HF53SH HF58SH HF63SH HF67SH HF73SH HF78SH HF88SH HF13SH HF15SH HF16SH HF19SH HF25SH HF26SH HF24SH HF25SH $ Price 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 Catalog No. ACF38EC ACF43EC ACF53EC ACF58EC ACF63EC ACF67EC ACF73EC ACF78EC ACF88EC ACF13EC ACF15EC ACF17EC ACF19EC ACF25EC ACF26EC ACF24EC ACF25EC $ Price 446.00 446.00 446.00 446.00 446.00 446.00 446.00 446.00 446.00 578.00 578.00 578.00 578.00 732.00 732.00 732.00 732.00 Wall Flange Catalog No. ACF38WF ACF43WF ACF53WF ACF58WF ACF63WF ACF67WF ACF73WF ACF78WF ACF88WF ACF13WF ACF15WF ACF17WF ACF19WF ACF25WF ACF26WF ACF24WF ACF25WF $ Price 418.00 418.00 418.00 418.00 418.00 418.00 418.00 418.00 418.00 418.00 418.00 418.00 606.00 606.00 606.00 606.00 606.00
800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000
For seismic applications, seismic hangers must be used with horizontal mount flatwise or edgewise busway. Vertical mount busway may use standard fixed or spring hangers.
PE8
Discount Schedule
Modified 1/14/11
12-5
12
BUSWAY
I-Line II Busway
Table 12.24:
Number of Poles and Voltage
Footage
Indoor Feeder/ Plug-In/Riser Standard High Short Short Circuit Circuit $ Price $ Price Per Foot Per Foot 394.00 440.00 440.00 496.00 592.00 644.00 682.00 732.00 838.00 894.00 1004.00 1062.00 1222.00 1282.00 1398.00 1464.00 1748.00 1830.00 1912.00 2008.00 478.00 528.00 578.00 628.00 722.00 772.00 826.00 884.00 1000.00 1046.00 1222.00 1282.00 1500.00 1546.00 1744.00 1810.00 2180.00 2263.00 2342.00 2430.00 Aluminum Busway Drip Resistant Feeder/ Plug-in/Riser Standard High Short Short Circuit Circuit $ Price $ Price Per Foot Per Foot 428.00 478.00 488.00 548.00 654.00 710.00 752.00 808.00 926.00 990.00 1100.00 1164.00 1350.00 1416.00 1540.00 1612.00 1925.00 2015.00 2106.00 2212.00 520.00 584.00 632.00 686.00 796.00 852.00 914.00 978.00 1094.00 1144.00 1350.00 1416.00 1648.00 1698.00 1914.00 1986.00 2393.00 2483.00 2572.00 2672.00 Outdoor Feeder Standard Short Circuit $ Price Per Foot 462.00 536.00 714.00 822.00 1014.00 1194.00 1478.00 1682.00 2103.00 2300.00 562.00 686.00 870.00 1000.00 1186.00 1478.00 1796.00 2084.00 2605.00 2802.00 High Short Circuit $ Price Per Foot 514.00 598.00 774.00 884.00 1084.00 1264.00 1550.00 1760.00 2200.00 2416.00 640.00 744.00 930.00 1070.00 1240.00 1550.00 1848.00 2162.00 2703.00 2912.00 Indoor Feeder/ Plug-in Riser Standard High Short Short Circuit Circuit $ Price $ Price Per Foot Per Foot 644.00 708.00 682.00 736.00 884.00 942.00 1032.00 1088.00 1186.00 1282.00 1514.00 1594.00 1922.00 1972.00 2288.00 2362.00 2608.00 2692.00 2978.00 3070.00 3570.00 3686.00 834.00 918.00 986.00 1046.00 1180.00 1252.00 1318.00 1394.00 1594.00 1680.00 1962.00 2024.00 2404.00 2482.00 3062.00 3124.00 3491.00 3561.00 3872.00 3950.00 4690.00 4784.00 Copper Busway Drip Resistant Feeder/ Plug-in/Riser Standard High Short Short Circuit Circuit $ Price $ Price Per Foot Per Foot 712.00 784.00 754.00 814.00 974.00 1036.00 1118.00 1182.00 1310.00 1416.00 1670.00 1756.00 2112.00 2168.00 2520.00 2602.00 2872.00 2966.00 3274.00 3376.00 3928.00 4054.00 932.00 1024.00 1084.00 1152.00 1298.00 1378.00 1452.00 1538.00 1754.00 1846.00 2162.00 2230.00 2648.00 2734.00 3368.00 3436.00 3840.00 3917.00 4256.00 4340.00 5156.00 5258.00 Outdoor Feeder Standard Short Circuit $ Price Per Foot 778.00 826.00 1062.00 1204.00 1434.00 1824.00 2300.00 2752.00 3137.00 3570.00 4284.00 1028.00 1182.00 1416.00 1584.00 1912.00 2362.00 2892.00 3672.00 4186.00 4640.00 5622.00 High Short Circuit $ Price Per Foot 860.00 892.00 1130.00 1274.00 1550.00 1916.00 2362.00 2842.00 3240.00 3682.00 4420.00 1130.00 1256.00 1504.00 1680.00 2012.00 2434.00 2986.00 3746.00 4270.00 4730.00 5732.00
Ampere Rating
800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000
Riser Busway
We also offer a Riser Plug-In busway with openings on one side only for riser installations. This busway offers the same short circuit ratings as our standard plug-in busway.
Prepare a layout sketch of the busway run showing: All dimensions in feet and inches All wall and floor locations and thicknesses All fittings (use top of page 12-7 as checklist) Add all dimensions together. Round up to the next foot. Multiply this total by the appropriate price per foot according to the tables above. To this, add the labor only charges for all fittings from page 12-7. Add hangers per page 12-8 (quantities explained below) Add for any other unit price items such as end closures, wall flanges, or special lug requirements from page 12-8.
12
BUSWAY
Hangers
Hangers for the I-Line II busway should be priced from the table on page 12-8. Indoor horizontal busway requires one hanger for every 10 feet of busway. Vertical indoor busway requires one hanger for every 16 feet. Outdoor feeder busway requires one hanger for every 5 feet in either vertical or horizontal mounting.
Elbows
The elbow labor only charge applies to all types of 90o elbows within a particular rating of busway. The charge does not include any busway footage (i.e. a charge for the appropriate amount of busway footage would have to be added to the labor only charge to obtain a complete device charge). If elbow is other than 90o, double the labor only charge.
Tee
The labor charge for tees shown in Table 12.25 on page 7 applies to all factory assembled types of 90 tee fittings within a given rating. Dimensions and catalog number suffix of flatwise tee fittings will be found in the Class 5600 Manual. Refer to factory for edgewise tee dimensions. Crosses are also available.
12-6
PE8
Discount Schedule
I-Line II Busway
www.schneider-electric.us
Table 12.25:
Number of Poles and Voltage
Fittings
Labor Only Charges for Each Component (Copper or Aluminum) Elbow Right Elbow Other Angle Than 90o 1464.00 1464.00 1966.00 1966.00 1966.00 1966.00 1966.00 1966.00 2478.00 2478.00 2478.00 1792.00 1792.00 2478.00 2478.00 2478.00 2478.00 2478.00 2478.00 2918.00 2918.00 2918.00 2928.00 2928.00 3932.00 3932.00 3932.00 3932.00 3932.00 3932.00 4956.00 4956.00 4956.00 3584.00 3584.00 4956.00 4956.00 4956.00 4956.00 4956.00 4956.00 5836.00 5836.00 5836.00 Flanged End 1512.00 1722.00 1900.00 2016.00 2202.00 2624.00 3134.00 3706.00 4447.00 4606.00 5384.00 1598.00 1908.00 2046.00 2144.00 2482.00 2880.00 3486.00 4130.00 4956.00 5136.00 6416.00 Tap Box or Service Head 4416.00 4552.00 4760.00 4876.00 5088.00 5420.00 6412.00 6838.00 7612.00 7778.00 9894.00 5010.00 5230.00 5450.00 5598.00 5846.00 6394.00 7756.00 8468.00 9463.00 9676.00 11044.00 Unfused Reducer 1334.00 1512.00 2514.00 3256.00 3610.00 4578.00 4768.00 7094.00 8512.00 8954.00 11084.00 1722.00 2024.00 3454.00 4404.00 4778.00 6422.00 7932.00 9538.00 11445.00 12754.00 14984.00 Fused or Expansion C/B Cubicle FTG. 20826.00 24108.00 28938.00 35192.00 41174.00 21232.00 24854.00 30526.00 37208.00 43144.00 3950.00 4214.00 4330.00 4396.00 5926.00 6468.00 6944.00 8704.00 10229.00 10556.00 11092.00 4358.00 4958.00 5916.00 6552.00 7944.00 8436.00 9126.00 11978.00 13457.00 13774.00 14484.00 Phase Bussed Transition XFMR Conn. 10890.00 11158.00 11274.00 11340.00 12872.00 13404.00 13886.00 15646.00 17172.00 17500.00 18030.00 11296.00 11902.00 12858.00 13496.00 14882.00 15380.00 16070.00 18922.00 20397.00 20714.00 21428.00 11164.00 12112.00 13270.00 13690.00 14654.00 15816.00 17594.00 19562.00 23474.00 25188.00 32432.00 12514.00 13700.00 15076.00 15566.00 16890.00 17996.00 20380.00 22350.00 26820.00 29248.00 36712.00 Transformer Taps One 3 Three 1 XFMR XFMRS Y or s Y or s 1968.00 6440.00 2284.00 6636.00 2492.00 6944.00 2636.00 7112.00 2918.00 7420.00 3342.00 7904.00 3966.00 9144.00 4652.00 10602.00 5304.00 11891.00 5444.00 12168.00 5950.00 14072.00 2066.00 6684.00 2458.00 6982.00 2668.00 7278.00 2806.00 7470.00 3186.00 7802.00 3606.00 8532.00 4326.00 9960.00 5074.00 11622.00 5795.00 13139.00 5950.00 13464.00 7420.00 15216.00
Ampere Rating 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000
Tee 1792.00 1792.00 2482.00 2482.00 2482.00 2482.00 2482.00 2482.00 2918.00 2918.00 2918.00 2084.00 2084.00 2918.00 2918.00 2918.00 2918.00 2918.00 2918.00 3412.00 3412.00 3412.00
Cross 3584.00 3584.00 4964.00 4964.00 4964.00 4964.00 4964.00 4964.00 5836.00 5836.00 5836.00 4168.00 4168.00 5836.00 5836.00 5836.00 5836.00 5836.00 5836.00 6824.00 6824.00 6824.00
Service Heads
Service heads are of outdoor construction and include Square D brand standard lugs. Price footage to end of busway run including dimension of service head. Add service head labor charge.
Unfused Reducer
Unfused reducers are used to reduce from a higher amperage busway to a lower amperage. Price each rating of busway to the centerline of reducer and include the labor only price of the higher rating. NOTE: The National Electric Code does not allow the use of unfused reducers in vertical riser installations. Refer to the NEC for restrictions in industrial installations.
Expansion Fittings
Expansion fitting labor only charge does not include busway footage. The expansion fitting is built into a 3 ft. 4 in. straight length for 800 A5000 A and a 5 feet 0 inch straight length for 225 A600 A. Limit of expansion or contraction is 1-1/2 inches. Not available in outdoor construction.
Transformer Taps
Transformer taps are used to make cable connection to transformers. Calculate footage price to end of busway. Use standard dimensions. Price of taps includes lugs; if lugs other than standard Square D brand lugs are required, add charges from page 12-8. Note that taps need NOT be located directly above transformers for cable connections.
This feature provides improved protection from accidental contact with live parts during insertion and removal of plug-in units. This feature meets the IP2X rating as defined by IEC529 standard. (Pricing on page 12-8.)
PE8
Discount Schedule
12-7
12
I-Line II Busway
870.00 2346.00
64.00 64.00
Aluminum Busway 800 A through 1200 A 2000 A through 2500 A 3000 A through 4000 A Lugs Other than Square D Standard Lugs Square D Standard added to flanged end Sway Brace Collar HP1SBC Assembly Tool AT2
Finger Protection to IP2X (For each plug-in opening) Plug-in Busway only Note: Finger protection can be ordered on I-Line II (8005000 A) plug-in busway only.
per foot
17.00
Table 12.27:
Ampere Rating 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000
12
BUSWAY
12-8
PE8
Discount Schedule
I-Line II Busway
www.schneider-electric.us
Plug-In Units
Class 5615, 5630 / Refer to Catalog 5600CT9101
Table 12.28:
Amp Rating
Hook-Swing Mounting
240 Vac 120/208 Vac, (240 Vac Max.) 600 Vac 277/480 Vac, (600 Vac Max.) 3-Pole, 3 Fuse + G 4-Pole, 3 Fuse + G 3-Pole, 3 Fuse + G 4-Pole, 3 Fuse + G Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price 30 PQ3203G 972.00 PQ4203G 1136.00 PQ3603G 1042.00 PQ4603G 1182.00 60 PQ3206G 1042.00 PQ4206G 1182.00 PQ3606G 1110.00 PQ4606G 1230.00 100 PQ3210G 1478.00 PQ4210G 1604.00 PQ3610G 1512.00 PQ4610G 1734.00 200 Plug-in PQ3220G 2462.00 PQ4220G 2728.00 PQ3620G 2566.00 PQ4620G 2866.00 200a PS3220G a 2462.00 PS4220G a 2728.00 PS3620G a 2566.00 PS4620G a 2866.00 400 PBQ3640G b 6442.00 PBQ4640G b 6996.00 PBQ3640G b 6442.00 PBQ4640G b 6996.00 600 PBQ3660G b 9224.00 PBQ4660G b 10090.00 PBQ3660G b 9224.00 PBQ4660G b 10090.00 800 PTQ3680G ( ) c 16014.00 PTQ4680G ( ) c 19312.00 1000 PTQ36100G ( ) c 18810.00 PTQ46100G( ) c 19436.00 Bolt-on 1200 PTQ36120G ( ) c 30042.00 PTQ46120G( ) c 30168.00 1600 PTQ36160G( ) c 30042.00 PTQ46160G( ) c 30168.00 Class J Fuses Provisions for installing Class J fuses are included in 30 through 600 A fusible devices. Conversion to Class J fuse spacing requires relocating the load side fuse base assembly from standard Class H fuse location to an alternate position in the enclosure. a For use on vertical riser applications only. b For vertical riser applications order auxiliary mounting kitCatalog Number PBQ4060RMK. (Price $300.) c This device uses bolt-on connection. It may be used only on plug-in busway with same number of poles. Add suffix (H) for horizontal applications and suffix (V) for vertical applications. Not for use on 800 A copper busway. Type of Connection
100 and All 200 400 and All 600 Class R Fuse Kits when installed reject all but class R fuses. d Kit must be field installed. e Contains parts to convert two units.
Table 12.30:
Circuit Breaker Frame Trip Rating (A) 15 20 30 40 50 60 70 80 90 100
FAf
Table 12.31:
Circuit Breaker Frame
PE7
Discount Schedule
Modified 1/14/11
12-9
12
BUSWAY
277/480 Vac (600 Vac Max.) Trip 600 Vac 3-Pole + G Type of 34W + G Rating Connection Amps Catalog No. $ Price Catalog No. $ Price 300 PBLA36300G 9398.00 PBLA36300GN 9890.00 LAf 350 Plug-in PBLA36350G 9398.00 PBLA36350GN 9890.00 400 PBLA36400G 9398.00 PBLA36400GN 9890.00 500 PTMA36500G ( )gh 16014.00 PTMA36500GN ( )gh 16640.00 600 PTMA36600G ( )gh 16014.00 PTMA36600GN ( )gh 16640.00 700 PTMA36700G ( )g 16014.00 PTMA36700GN ( )g 16640.00 MAf Bolt-on 800 PTMA36800G ( )g 16014.00 PTMA36800GN ( )g 16640.00 900 PTMA36900G ( )g 18810.00 PTMA36900GN( )g 19436.00 1000 PTMA36100G ( )g 18810.00 PTMA36100GN( )g 19436.00 1000 PTPA36100G( )g 29760.00 PTPA36100GN ( )g 30168.00 1200 PTPA36120G ( )g 29760.00 PTPA36120GN ( )g 30168.00 PAf Bolt-on 1400 PTPA36140G ( )g 29760.00 PTPA36140GN ( )g 30168.00 1600 PTPA36160G ( )g 29760.00 PTPA36160GN ( )g 30168.00 f Other trip ratings available on an order only basis. Contact your nearest Schneider Electric sales office for order details. This device uses bolt-on connection. It may be used only on busway with same number of poles: i.e., do not use 3-pole unit g on 34W busway, or 34W unit on 3-pole busway. Add suffix (H) for horizontal applications and suffix (V) for vertical applications. Not for use on 800 A copper busway. h Cannot be used on 600 A bus. Use devices with the prefix PBMA.
I-Line II Busway
Plug-In Units
Class 5600 / Refer to Catalog 5600CT9101
www.schneider-electric.us
Table 12.32:
Breaker Frame
Table 12.35:
Circuit Breaker Frame Trip Rating Amps 300 350 400 500 600
600 Vac 277/480 Vac (600 Vac Max.) Trip Type of 3-Pole + G 34W + G Rating Connection Amps Catalog No. $ Price Catalog No. $ Price 15 PFH36015G 2394. PFH36015GN 2578. 20 PFH36020G 2394. PFH36020GN 2578. 30 PFH36030G 2394. PFH36030GN 2578. 40 PFH36040G 2394. PFH36040GN 2578. 50 PFH36050G 2394. PFH36050GN 2578. FH Plug-In 60 PFH36060G 2394. PFH36060GN 2578. 70 PFH36070G 2582. PFH36070GN 2784. 70 PFH36080G 2582. PFH36080GN 2784. 90 PFH36090G 2582. PFH36090GN 2784. 100 PFH36100G 2582. PFH36100GN 2784. 300 PBLH36300G 12846. PBLH36300GN 13322. 350 PBLH36350G 12846. PBLH36350GN 13322. 12846. PBLH36400GN 13322. 400 PBLH36400G LH Plug-In 500 PTMH36500G( )ab 17918. PTMH36500GN ( )ab 18536. 600 PTMH36600G( )ab 17918. PTMH36600GN( )ab 18536. 700 PTMH36700G( )a 17918. PTMH36700GN( )a 18536. 800 PTMH36800G( )a 17918. PTMH36800GN( )a 18536. MH Bolt-On 900 PTMH36900G( )a 20368. PTMH36900GN( )a 22082. 1000 PTMH36100G( )a 20368. PTMH36100GN( )a 22082. a This device uses bolt-on connection. It may be used only on busway with same number of poles. Add suffix (H) for horizontal applications and suffix (V) for vertical applications. Not for use on 800 A copper busway. b Note: Cannot be used on 600 A busway. Use devices with the prefix PBMH.
LC
Plug-In
Table 12.36:
Table 12.33:
Trip Breaker Rating Type of Frame Amps Connection 20 30 40 50 FI 60 Plug-In 70 80 90 100 125 150 175 KI Plug-In 200 225 250 300 350 400 LI Plug-In 500 600
Extra High Capacity 277/480 Vac (600 Vac Max.) 34W + G Catalog Catalog $ Price $ Price Number Number 100 PBLX36100G 12420. PBLX36100GN 13068. 200 PBLX36200G 12420. PBLX36200GN 13068. LX 300 Plug-In PBLX36300G 16230. PBLX36300GN 16878. 350 PBLX36350G 16230. PBLX36350GN 16878. 400 PBLX36400G 16230. PBLX36400GN 16878. 500 PTMX36500G( )d 25450. PTMX36500GN( )d 26545. 600 PTMX36600G( )d 25450. PTMX36600GN( )d 26545. MX Bolt-On 700 PTMX36700G( )d 25450. PTMX36700GN( )d 26545. 800 PTMX36800G ( )d 25450. PTMX36800GN( )d 26545. 1000 PTPX36100G( )d 35794. PTPX36100GN( )d 36878. PX Bolt-On 1600 PTPX36160G( )d 35794. PTPX36160GN( )d 36878. c Solid state trip circuit breakers are supplied with -LSI (long time, short time, instantaneous pickup) adjustable trip unit functions unless otherwise required. Adjust prices accordingly (see circuit breakers, section 7) if ground fault protection, neutral current transformer, 100% rated circuit breaker or alternate trip unit functions are required. d This device uses bolt-on connection. It may be used only on busway with same number of poles. Add suffix (H) for horizontal applications and suffix (V) for vertical applications. Not for use on 800 A copper busway.
Table 12.37:
Table 12.34:
600 Vac 277/480 Vac (600 Vac Max.) Trip Breaker Rating Type of 3-Pole + G 34W + G Frame Amps Connection Catalog No. $ Price Catalog No. $ Price 300 PBLXI36300G 26606. PBLXI36300GN 27254. 350 PBLXI36350G 26606. PBLXI36350GN 27254. LXI 400 Plug-In PBLXI36400G 26606. PBLXI36400GN 27254. 500 PBLXI36500G 37712. PBLXI36500GN 38642. 600 PBLXI36600G 37712. PBLXI36600GN 38642. 700 PTMA36700GCL( )ab 27252. PTMA36700GNCL( )ab 27876. 800 MA Bolt-On PTMA36800GCL( )ab 27252. PTMA36800GNCL( )ab 27876. 900 PTMA36900GCL( )ab 30286. PTMA36900GNCL( )ab 30914. 1000 PTMA36100GCL( )ab 30286. PTMA36100GNCL( )ab 30914. a This device uses bolt-on connection. It may be used only on busway with same number of poles. Add suffix (H) for horizontal applications and suffix (V) for vertical applications. Not for use on 800 A copper busway. b Includes Square D brand standard circuit breaker plus set of three coordinated current limiting fuses.
Trip Rating Trip Amps Function LI LSI 300 LIG LSIG LI LSI 400 LIG LSIG LI LSI 500 LIG LSIG LI LSI 600 LIG LSIG
12
BUSWAY
12-10
PE7
Discount Schedule
Modified 1/14/11
I-Line II Busway
www.schneider-electric.us
Table 12.38:
Trip D Interrupting Rating Catalog Number Amps 3-pole + G, 600 Vac 50/60 Hz 15 PHD36015G 20 PHD36020G 25 PHD36025G 30 PHD36030G 35 PHD36035G 40 PHD36040G 45 PHD36045G 50 PHD36050G 60 PHD36060G 70 PHD36070G 80 PHD36080G 90 PHD36090G 100 PHD36100G 110 PHD36110G 125 PHD36125G 150 PHD36150G
Table 12.39:
Trip D Interrupting Rating Catalog Number $ Price Amps 34W + G, 277/480 Vac (600 Vac Max) 50/60 Hz 15 PHD36015GN 2111.00 20 PHD36020GN 2111.00 25 PHD36025GN 2111.00 30 PHD36030GN 2111.00 35 PHD36035GN 2111.00 40 PHD36040GN 2111.00 45 PHD36045GN 2111.00 50 PHD36050GN 2111.00 60 PHD36060GN 2111.00 70 PHD36070GN 2317.00 80 PHD36080GN 2317.00 90 PHD36090GN 2317.00 100 PHD36100GN 2317.00 110 PHD36110GN 4478.00 125 PHD36125GN 4478.00 150 PHD36150GN 4478.00
Table 12.40:
Trip D Interrupting Rating Catalog Number Amps 3-pole + G, 600 Vac 50/60 Hz 175 PJD36175G 200 PJD36200G 225 PJD36225G 250 PJD36250G
Table 12.41:
Trip D Interrupting Rating Catalog Number $ Price Amps 34W + G, 277/480 Vac (600 Vac Max) 50/60 Hz 175 PJD36175GN 4950.00 200 PJD36200GN 4950.00 225 PJD36225GN 4950.00 250 PJD36250GN 6712.00
Table 12.42:
Interrupting Ratings (kA) 240 V 480 V 600 V
PE7
Discount Schedule
Modified 1/14/11
12-11
12
BUSWAY
I-Line II Busway
Table 12.43:
Micrologic Standard Trip Unit ab 3-pole + G, 600 Vac 50/60 Hz With LI Trip Functions (Micrologic 3.0) 600 PTRG36060G( )U31Ad 42232.00 48472.00 800 PTRG36080G( )U31A 42232.00 48472.00 1000 PTRG36100G( )U31A 42232.00 48472.00 1200 PTRG36120G( )U31A 42232.00 48472.00 1600 PTRG36160G( )U31A 42232.00 3-pole, 600 Vac 50/60 Hz With LSI Trip Functions (Micrologic 5.0) 600 PTRG36060G( )U33Ad 42686.00 800 PTRG36080G( )U33A 42686.00 1000 PTRG36100G( )U33A 42686.00 1200 PTRG36120G( )U33A 42686.00 1600 PTRG36160G( )U33A 42686.00 Micrologic Ammeter Trip Unitab 48772.00 48772.00 48772.00 48772.00 PTRJ36060G( )U31Ad PTRJ36080G( )U31A PTRJ36100G( )U31A PTRJ36120G( )U31A PTRJ36160G( )U31A PTRJ36060G( )U33Ad PTRJ36080G( )U33A PTRJ36100G( )U33A PTRJ36120G( )U33A PTRJ36160G( )U33A 43800.00 43800.00 43800.00 43800.00 43800.00 44254.00 44254.00 44254.00 44254.00 44254.00 50040.00 50040.00 50040.00 50040.00 50340.00 50340.00 50340.00 50340.00 PTRL36060G( )U31Ad PTRL36080G( )U31A PTRL36100G( )U31A PTRL36120G( )U31A PTRL36160G( )U31A PTRL36060G( )U33Ad PTRL36080G( )U33A PTRL36100G( )U33A PTRL36120G( )U33A PTRL36160G( )U33A 45366.00 45366.00 45366.00 45366.00 45366.00 45820.00 45820.00 45820.00 45820.00 45820.00 51606.00 51606.00 51606.00 51606.00 51906.00 51906.00 51906.00 51906.00
3-pole, 600 Vac 50/60 Hz With LI Trip Functions (Micrologic 3.0) 600 PTRG36060G( )U41Ad 43368.00 49342.00 800 PTRG36080G( )U41A 43368.00 49342.00 1000 PTRG36100G( )U41A 43368.00 49342.00 1200 PTRG36120G( )U41A 43368.00 49342.00 1600 PTRG36160G( )U41A 43368.00 3-pole, 600 Vac 50/60 Hz With LSI Trip Functions (Micrologic 5.0) 600 PTRG36060G( )U43Ad 45366.00 51184.00 800 PTRG36080G( )U43A 45366.00 51184.00 1000 PTRG36100G( )U43A 45366.00 51184.00 1200 PTRG36120G( )U43A 45366.00 51184.00 1600 PTRG36160G( )U43A 45366.00 3-pole, 600 Vac 50/60 Hz With LSIG Trip Functions (Micrologic 6.0) 600 PTRG36060G( )U44Ad 47856.00 53426.00 800 PTRG36080G( )U44A 47856.00 53426.00 1000 PTRG36100G( )U44A 47856.00 53426.00 1200 PTRG36120G( )U44A 47856.00 53426.00 1600 PTRG36160G( )U44A 47856.00
PTRJ36060G( )U41Ad PTRJ36080G( )U41A PTRJ36100G( )U41A PTRJ36120G( )U41A PTRJ36160G( )U41A PTRJ36060G( )U43Ad PTRJ36080G( )U43A PTRJ36100G( )U43A PTRJ36120G( )U43A PTRJ36160G( )U43A PTRJ36060G( )U44Ad PTRJ36080G( )U44A PTRJ36100G( )U44A PTRJ36120G( )U44A PTRJ36160G( )U44A
44936.00 44936.00 44936.00 44936.00 44936.00 46934.00 46934.00 46934.00 46934.00 46934.00 49424.00 49424.00 49424.00 49424.00 49424.00
50910.00 50910.00 50910.00 50910.00 52752.00 52752.00 52752.00 52752.00 54994.00 54994.00 54994.00 54994.00
PTRL36060G( )U41Ad PTRL36080G( )U41A PTRL36100G( )U41A PTRL36120G( )U41A PTRL36160G( )U41A PTRL36060G( )U43Ad PTRL36080G( )U43A PTRL36100G( )U43A PTRL36120G( )U43A PTRL36160G( )U43A PTRL36060G( )U44Ad PTRL36080G( )U44A PTRL36100G( )U44A PTRL36120G( )U44A PTRL36160G( )U44A
46502.00 46502.00 46502.00 46502.00 46502.00 48500.00 48500.00 48500.00 48500.00 48500.00 50990.00 50990.00 50990.00 50990.00 50990.00
52476.00 52476.00 52476.00 52476.00 54318.00 54318.00 54318.00 54318.00 56560.00 56560.00 56560.00 56560.00
Table 12.44:
Micrologic Standard Trip Unit ab 34W + G 277/480 Vac (600 Vac Max) 50/60 Hz With LI Trip Functions (Micrologic 3.0) 600 PTRG36060GN( )U31Ad 43232.00 49472.00 PTRJ36060GN( )U31Ad 800 PTRG36080GN( )U31A 43232.00 49472.00 PTRJ36080GN( )U31A 1000 PTRG36100GN( )U31A 43232.00 49472.00 PTRJ36100GN( )U31A 1200 PTRG36120GN( )U31A 43232.00 49472.00 PTRJ36120GN( )U31A 1600 PTRG36160GN( )U31A 43232.00 PTRJ36160GN( )U31A 34W + G 277/480 Vac (600 Vac Max) 50/60 Hz With LSI Trip Functions (Micrologic 5.0) 600 PTRG36060GN( )U33Ad 43686.00 49772.00 PTRJ36060GN( )U33Ad 800 PTRG36080GN( )U33A 43686.00 49772.00 PTRJ36080GN( )U33A 1000 PTRG36100GN( )U33A 43686.00 49772.00 PTRJ36100GN( )U33A 1200 PTRG36120GN( )U33A 43686.00 49772.00 PTRJ36120GN( )U33A 1600 PTRG36160GN( )U33A 43686.00 PTRJ36160GN( )U33A Micrologic Ammeter Trip Unitab 44800.00 44800.00 44800.00 44800.00 44800.00 45254.00 45254.00 45254.00 45254.00 45254.00 51040.00 PTRL36060GN( )U31Ad 51040.00 PTRL36080GN( )U31A 51040.00 PTRL36100GN( )U31A 51040.00 PTRL36120GN( )U31A PTRL36160GN( )U31A 51340.00 PTRL36060GN( )U33Ad 51340.00 PTRL36080GN( )U33A 51340.00 PTRL36100GN( )U33A 51340.00 PTRL36120GN( )U33A PTRL36160GN( )U33A 46366.00 46366.00 46366.00 46366.00 46366.00 46820.00 46820.00 46820.00 46820.00 46820.00 52606.00 52606.00 52606.00 52606.00 52906.00 52906.00 52906.00 52906.00
34W + G 277/480 Vac (600 Vac Max) 50/60 Hz With LI Trip Functions (Micrologic 3.0) 600 PTRG36060GN( )U41Ad 44368.00 50342.00 PTRJ36060GN( )U41Ad 45936.00 51910.00 PTRL36060GN( )U41Ad 47502.00 53476.00 800 PTRG36080GN( )U41A 44368.00 50342.00 PTRJ36080GN( )U41A 45936.00 51910.00 PTRL36080GN( )U41A 47502.00 53476.00 1000 PTRG36100GN( )U41A 44368.00 50342.00 PTRJ36100GN( )U41A 45936.00 51910.00 PTRL36100GN( )U41A 47502.00 53476.00 1200 PTRG36120GN( )U41A 44368.00 50342.00 PTRJ36120GN( )U41A 45936.00 51910.00 PTRL36120GN( )U41A 47502.00 53476.00 1600 PTRG36160GN( )U41A 44368.00 PTRJ36160GN( )U41A 45936.00 PTRL36160GN( )U41A 47502.00 34W + G 277/480 Vac (600 Vac Max) 50/60 Hz With LSI Trip Functions (Micrologic 5.0) 600 PTRG36060GN( )U43Ad 46366.00 52184.00 PTRJ36060GN( )U43Ad 47934.00 53752.00 PTRL36060GN( )U43Ad 49500.00 55318.00 800 PTRG36080GN( )U43A 46366.00 52184.00 PTRJ36080GN( )U43A 47934.00 53752.00 PTRL36080GN( )U43A 49500.00 55318.00 1000 PTRG36100GN( )U43A 46366.00 52184.00 PTRJ36100GN( )U43A 47934.00 53752.00 PTRL36100GN( )U43A 49500.00 55318.00 1200 PTRG36120GN( )U43A 46366.00 52184.00 PTRJ36120GN( )U43A 47934.00 53752.00 PTRL36120GN( )U43A 49500.00 55318.00 1600 PTRG36160GN( )U43A 46366.00 PTRJ36160GN( )U43A 47934.00 PTRL36160GN( )U43A 49500.00 34W + G 277/480 Vac (600 Vac Max) 50/60 Hz With LSIG Trip Functions (Micrologic 6.0) 600 PTRG36060GN( )U44Ad 48856.00 54426.00 PTRJ36060GN( )U44Ad 50424.00 55994.00 PTRL36060GN( )U44Ad 51990.00 57560.00 800 PTRG36080GN( )U44A 48856.00 54426.00 PTRJ36080GN( )U44A 50424.00 55994.00 PTRL36080GN( )U44A 51990.00 57560.00 1000 PTRG36100GN( )U44A 48856.00 54426.00 PTRJ36100GN( )U44A 50424.00 55994.00 PTRL36100GN( )U44A 51990.00 57560.00 1200 PTRG36120GN( )U44A 48856.00 54426.00 PTRJ36120GN( )U44A 50424.00 55994.00 PTRL36120GN( )U44A 51990.00 57560.00 1600 PTRG36160GN( )U44A 48856.00 PTRJ36160GN( )U44A 50424.00 PTRL36160GN( )U44A 51990.00 a The standard rating plug supplied with a trip unit will be the "A" rating plug. To specify an alternative rating plug, replace the "A" at the end of the catalog number with the applicable suffix letter. See the ratings plugs table on page 7-44 for rating plug catalog suffix letters. b All these devices use bolt-on connection. It may be used only on busway with same number of poles. Not for use on 800 A copper busway. To complete the catalog number, replace the blank with an (H) for horizontal applications and (V) for vertical applications. c Listed catalog numbers are for 80% rated circuit breakers. For 100% rated circuit breakers, replace the blank with an HC for horizontal applications and VC for vertical applications. For example, the catalog number for a 100% standard trip unit with LI trip functions at 800 A 33W for a horizontal application would be PTRG36080GHCU31A. d Special device. Contact your local Schneider Electric field office for ordering information.
12
BUSWAY
Table 12.45:
12-12
PE7
Discount Schedule
I-Line Busway
www.schneider-electric.us
Table 12.46:
Length 8'
Hooksticks
Catalog No. 515608 $ Price 452.00 Length 14' Catalog No. 515614 $ Price 778.00
Table 12.48:
System Voltage 208 Y/120 Vac, 34W/Grd. 240 Y/120 Vac, 34W/Grd. 480 Y/277 Vac, 34W/Grd. 600Y/347 Vac, 34W/Grd.
Table 12.49:
Options
Description When Required Add Suffix to Catalog Number C M CM $ Price 516.00 STD. 620.00 1136.00
Surge Counter Dry Contacts Remote Monitor with Dry Contacts Surge Counter and Remote Monitor with Dry Contacts
PE8
PE7
Discount Schedule
12-13
12
BUSWAY
Power-Zone Busway
Non-Segregated Bus
Class 6090 / Refer to Catalog 5600CT0201
www.schneider-electric.us
Non-segregated phase bus 600 V through 15 kV (1200 A4000 A) 1 Aluminum, steel or stainless steel housing Aluminum or copper bus bars Insulated with fluidized bed epoxy (5 kV15 kV) Complete line of fittings provides for any configuration Indoor trapeze and outdoor column supports For use in utilities, industrial and commercial facilities Power-Zone bus is custom designed, manufactured and tested per ANSI C37.23 standards to meet customer specifications. The 600 V product is also UL Listed. It is a completely coordinated package of equipment with all the auxiliary material and supports for connecting transformers, switchgear, MCCs, and motors, in all types of utility, industrial, and commercial facilities. General Pricing Instruction Prepare a layout sketch (if applicable) of the run(s) showing all dimensions in feet and inches, all wall and floor locations and thicknesses and all fittings such as elbows, tees, flanged ends, cable tap boxes, expansion fittings, transformer connections, etc. Add all dimensions together using the center line of the bus and adjust the total to the higher whole foot. Multiply this total by the per foot price as determined by the type (indoor or weatherproof) (aluminum or copper) and the number of poles and any optional accessories (aluminum or steel enclosures, fiberglass or porcelain conductor supports, etc.). To this add the charges for each of the elbows, tees, flanged ends, cable tap boxes, expansion fittings, transformer connections, etc. The sum of these items plus the sum of any optional accessory is the price of the entire bus run. NOTE: Because the bus run is custom designed and built there are no Complete Device prices. Bus Footage The per foot price of the bus may be a combination of several prices depending on the job specifications and requirements. Some of these options are special momentary rating, special housing material and/or finish, special conductor supports, heaters and thermostats, and ground bus. The prices for these options are shown on page 12-16. They should be added to the per foot prices shown on page 12-15. Weatherproof Bus Priced the same as indoor. In addition, all weatherproof runs must be equipped with strip heaters to eliminate condensation and, if applicable, a thermostat. A heater should be priced for every seven (7) foot of bus and no more than 20 heaters can be controlled by one thermostat. Also, each bus run should have its own thermostat. The heaters are rated 240 V, 500 watts and operate at 120 V, 125 watts. Flanged Ends A flanged end is used to terminate the bus into switchgear, motor control centers, switchboards, or any rigid bus-tobus connection. It consists of a gasketed equipment flange, up to 1'-0" of 33W conductor (34W as applicable), necessary insulation tapes, and required bolting hardware. If additional conductor length is required, add to the footage price on a per foot basis. Cable Tap Box A cable tap box includes a gasketed and accessible termination box, lugs, necessary insulation tape (between bus and lugs only), and required bolting hardware. Lug sizes and quantity should be specified by purchaser.
Transformer/Generator Connection This type of termination should be priced whenever the bus is connecting to a transformer, generator, motor, switch or any connection where the bus bars are connecting to porcelain mounted equipment terminals. It will include the same components as a flanged end plus one set of flexible braid type connectors and a terminal box (if required). Bushing Box (Weatherhead) A bushing box is used on service entrance run where the cable connection to the bus must be made via porcelain bushings. It is comprised of the same components as a transformer connection plus 3 through stud type apparatus bushings, bushing stud connectors (lug pads) and a strip heater. Ground Bus The bus housing is designed and constructed to provide an electrically continuous ground path. The side rails of the bus housings are capable of carrying the full rated phase current continuously and, under short circuit conditions, are capable of carrying up to 60 kA RMS asymmetrical fault current for 3 seconds. Consequently, a separate ground bus is not necessary unless specified. Wall Entrance Seal A wall entrance seal consists of a wall throat, wall flange (one side of wall only), and a barrier which prevents air or vapor from passing from one room to another or from outdoors to indoors. It also carries a 1/2 hour fire rating. Consult factory for higher fire ratings. If additional wall flanges are required, they should be added at the prices given on page 12-16. Equipment Entrance Seal An equipment entrance seal should be priced whenever a barrier is required to prevent the passing of flame and/or gasses between the bus housing and the terminating equipment. Expansion Fittings An expansion fitting is used to counteract the strain placed on the bus due to the expansion and contraction of the building or the bus itself. One should be priced whenever the bus run crosses a building expansion joint and whenever a straight run of bus exceeds 60 feet. Flexible Housing (Misalignment) Collar Required at terminations or wall penetrations when vibrations due to seismic forces may cause damage to the bus. It may also be used to adjust for the settling of terminating equipment after installation.
12
BUSWAY
12-14
Power-Zone Busway
www.schneider-electric.us
Non-Segregated Bus
Class 6090 / Refer to Catalog 5600CT0201
Supporting Steel (Hangers) Supports are not included in the per foot price of the bus and should be added on the basis of one for every 10 ft. for indoor and one for every 12 ft. for outdoor. Indoor supports are a trapeze type hanger while outdoor supports are a single or double column type support. Consult factory for other type supports. Hazardous or Seismic Locations Consult factory for bus runs which are to be installed in a location which is classified as hazardous or in a seismic location. Standard Construction The prices on this page are based on standard Power-Zone construction. Page 12-16 should be used to add any options or accessories. Standard construction is as follows: Conductor (plating): Copper (silver) or Aluminum (tin) Conductor Insulation (5 kV and 15 kV only): epoxy Conductor Supports: Glass reinforced polyester blocks Housing Material: Extruded Aluminum (1/8-inch Nominal) Housing Construction: Totally Enclosed Non-ventilated Joint Insulation: EPR and PVC tape BIL Rating: 25 kV (600 V), 60 kV (5 kV) and 95 kV (15 kV) Momentary (Short Circuit) Rating: 75 kA (600 V) and 60 kA (5 kV, 15 kV) Ground Conductor: Housing (100% rated) Table 12.50:
Cond. Mtl.
3P, 3W Aluminum
3P, 3W
Copper
Aluminum
3P, 3Wb
Copper
3P, 3Wb
a b
1200 A 1445. 4655. 4495. 4175. 14596. 1600 A 1550. 4765. 4570. 4275. 15092. 3P, 3Wb 2000 A 1745. 5190. 4640. 4405. 17479. 2500 A 1900. 5445. 4690. 4505. 17772. 3000 A 2205. 5700. 4760. 4685. 19165. 1200 A 1850. 5130. 4495. 4325. 15118. 1600 A 2225. 5555. 4570. 4330. 15961. 2000 A 2915. 6415. 4640. 4615. 18827. 2500 A 3220. 6925. 4690. 4695. 19763. 3P, 3Wb 3000 A 4385. 9380. 4760. 5493. 23213. 4000 A 6435. 11075. 6340. 6426. 27128. 5000 A 7305. 12065. 7435. 7519. 29712. 6000 A 8955. 14575. 10095. 8797. 34398. Hangers, supports and heater prices not included. See page 12-16 for pricing. Add 30% for 34W (half-neutral): add 45% for 34W (full-neutral).
Aluminum
PE8
Discount Schedule
12-15
12
BUSWAY
Copper
Power-Zone Busway
Space Heaters/Thermostats
Space heaters must be priced for all weatherproof applications. One heater should be priced for every 7 feet of outdoor bus. If a thermostat is specified to control the heaters, at least one should be priced for each bus run. No more than 20 heaters can be controlled by each thermostat. Table 12.51:
Description Thermostat 120 V, 125 W space heater (240 V, 500 W rated) $ Price Each 800.00 680.00
Non-Segregated Bus
Class 6090 / Refer to Catalog 5600CT0201
www.schneider-electric.us
Table 12.54:
Bus Enclosures
Per Foot $ Price Adder Standard 680.00 800.00 1600.00 2160.00
Material and Finish Painted Aluminum (1/8 Nominal) Painted 14 Gauge Steel Painted 11 Gauge Steel Unpainted 14 Gauge 304 Stainless Steel Unpainted 14 Gauge 316 Stainless Steel
Hangers/Supports
Hangers and supports are not included in prices on page 12-15. Price one indoor hanger for every 10 feet (maximum) of indoor bus and one outdoor support for every 12 feet (maximum) of outdoor bus (if required). Table 12.52:
Support Description Indoor Trapeze Hanger Outdoor, Single Column Support Maximum Height 6 feet 8 feet 10 feet 12 feet 14 feet 16 feet 18 feet 20 feet 22 feet $ Price Each 820.00 5709.00 6524.00 7340.00 8155.00 14995.00 16495.00 17994.00 19494.00 20993.00
Table 12.56:
Voltage Class 600 V 5 kV 15 kV e 1200 A
Flexible Connectors
$ Price Per Three Phase Connectione 1600 A 2000 A 2500 A 3000 A 4000 A
Construction Options
Table 12.53:
Voltage Class
9175.00 10045.00 12425.00 16705.00 22245.00 9300.00 10155.00 12535.00 16890.00 22440.00 9405.00 10265.00 12705.00 17085.00 22635.00
Add 45% for 34W (100%) connection. Add 30% for 34W (50%).
Amperage $ Price Per Foot c Multiplier 75 KA Standard 600 V 100 KA 1.25 150 KA 1.50 60 KA Standard 5 kV 80 KA 1.05 100 KA 1.25 60 KA Standard 80 KA 1.05 15 kV 100 KA 1.25 150 KA 1.50 Include base price (page 12-15) plus all options.
Table 12.57:
Box Size 3' x 2' x 3' 3' x 3' x 4' 4' x 3' x 4' 4' x 4' x 5' 5' x 4' x 5' 5' x 5' x 5'
Terminal Boxes
11 Gauge Steel 8350.00 9895.00 11195.00 11935.00 12740.00 14020.00 3/16 Aluminum 11690.00 13853.00 15673.00 16709.00 17836.00 19628.00
Table 12.58:
Miscellaneous Additions
Description $ Price PVC insulating boots: (optional)a Splice (joint) (33W) 2000.00 Termination (33W) 2000.00 Wall Flange: (optional) (in addition to wall entrance seal) Aluminum 1750.00 14 Gauge Steel 1250.00 14 Gauge 304 Stainless Steel 2000.00 14 Gauge 316 Stainless Steel 2600.00 Optional Conductor Support High Alumina Porcelainb 1150.00 Flexible Housing (Misalignment) Collar (optional) 3560.00 a Add 45% for 34W (100%) connection. Add 30% for 34W (50%). b Per foot
12
BUSWAY
12-16
PE8
Discount Schedule
Table of Contents
Section 13
Wire Management
Wireway
General Purpose Wireway Oiltight Wireway Raintight Wireways Raintight Troughs 13-2 13-3 13-3 13-3
WIRE MANAGEMENT
Wall Duct
Wireway pp. 13-2
13-4 13-5
Trench Duct
Straight Sections and Fittings Accessories and Components 13-6 13-6
13-1
13
Wireway
Class 5100 / Refer to Catalog 5100CT0101
www.schneider-electric.us
13
WIRE MANAGEMENT
Sizes
2-1/2, 4, and 6 sizes are manufactured from 16 gauge steel. Straight lengths are available with or without knockouts. Knockouts are of various sizes in sides and bottom of wireway. 8, 10, and 12 sizes are made of 14 gauge steel and are furnished without knockouts. Table 13.1:
Component
2-1/2" x 2-1/2" 4" x 4" 6" x 6" 8" x 8" Catalog Number Catalog Number Catalog Number Cat. No. $ Price $ Price $ Price With Without With Without With Without $ Price Without Knockouts Knockouts Knockouts Knockouts Knockouts Knockouts Knockouts Painted Hinge-Cover 1' Length LDB21KO LDB21 24.00 LDB41KO LDB41 26.10 LDB61KO LDB61 48.20 LDB81 76.00 2' Length LDB22KO LDB22 34.80 LDB42KO LDB42 38.50 LDB62KO LDB62 59.00 LDB82 116.00 3' Length LDB23KO LDB23 44.20 LDB43KO LDB43 54.00 LDB63KO LDB63 84.00 LDB83 177.00 4' Length LDB24KO LDB24 61.00 LDB44KO LDB44 75.00 LDB64KO LDB64 111.00 LDB84 215.00 5' Length LDB25KO LDB25 75.00 LDB45KO LDB45 80.00 LDB65KO LDB65 120.00 LDB85 240.00 6' Length LDB46KO LDB46 96.00 LDB66KO LDB66 151.00 LDB86 284.00 10' Length LDB210KO LDB210 151.00 LDB410KO LDB410 167.00 LDB610KO LDB610 284.00 LDB810 507.00 o 90 L LDB290L 54.00 LDB490L 61.00 LDB690L 69.00 LDB890L 111.00 90o Sweep L LDB290LS 95.00 LDB490LS 107.00 LDB690LS 155.00 LDB890LS 200.00 oL LDB245L 54.00 LDB445L 66.00 LDB645L 69.00 LDB845L 111.00 45 Tee LDB2T 62.00 LDB4T 75.00 LDB6T 84.00 LDB8T 155.00 Junction Box LDB2J 69.00 LDB4J 84.00 LDB6J 104.00 LDB8J 164.00 Telescope Ftg. LDB2TF 101.00 LDB4TF 111.00 LDB6TF 131.00 LDB8TF 218.00 Connectora LDB2C 7.70 LDB4C 9.50 LDB6C 11.40 LDB8C 23.10 Drop/Brkt Hgr. LDB2H 14.80 LDB4H 17.10 LDB6H 30.80 LDB8H 44.60 Support Hanger LDB2SH 9.20 LDB4SH 12.60 LDB6SH 22.10 LDB8SH 31.50 Closing Plate LDB2CPKO LDB2CP 7.70 LDB4CPKO LDB4CP 9.50 LDB6CPKO LDB6CP 11.40 LDB8CPb 15.50 Panel Adapter LDB2A 23.00 LDB4A 27.10 LDB6A 35.40 LDB8A 48.20 Open Adapter LDB2OA 30.50 LDB4OA 45.20 LDB6OA 59.00 LDB8OA 74.00 LDB42R 39.80 LDB64R 69.00 LDB86R 80.00 Reducer Adapter LDB2GASK 23.00 LDB4GAS 29.10 LDB6GAS 36.50 LDB8GASK 44.20 to LDc Barrier Kit5 ft. LJB45B 34.80 LJB65B 70.00 LJB85B 87.00 long w/hardware 5 pc. Barrier LJB45BKM 79.00 LJB65BKM 120.00 Pack5 ft. long 5 pc. Barrier Bracket LJB4BB2C 23.10 LJB6BB2C 80.00 2 compartment 5 pc. Barrier Bracket LJB4BB3C 49.40 LJB6BB3C 96.00 3 compartment a Add connectors for all lengths and fittings, except closing plates, reducers, and adapters. b These closing plates also available with knockout. Add "KO" to cat #; price is the same. c Adapters to competitors wireways also available. Contact your nearest Schneider Electric sales office for price and availability. d Painted 12" x 12" wireway is not furnished with hinge-cover (screw-cover only).
13-2
Wireway
Class 5100 / Refer to Catalog 5100CT0101
www.schneider-electric.us
OiltightNEMA Type 12
Type LJB Oiltight lay-in wireway is fully gasketed and used to protect runs of electrical wiring from oil, water, coolants, dirt, or dust as well as physical damage. This wireway is manufactured to exceed oiltight and NFPA standards for industrial control equipment. Table 13.2: Type LJB Lay-inb
2-1/2" x 2-1/2" Catalog No. $ Price 1" Nipple LJB201 74.00 2" Nipple LJB202 80.00 3" Nipple LJB203 84.00 6" Length LJB206 92.00 1' Length LJB21 99.00 2' Length LJB22 129.00 3' Length LJB23 147.00 4' Length LJB24 186.00 5' Length LJB25 201.00 10' Lengtha LJB210 352.00 o Top Opening LJB245LT 201.00 45 o Inside Opening LJB245LI 159.00 45 45o Outside Opening LJB245LO 159.00 o Inside Opening LJB290LI 159.00 90 o Outside Opening LJB290LO 159.00 90 o Outside Top Opening 90 o 90 Top Opening LJB290LT 159.00 TeeTop Opening LJB2TT 188.00 TeeOutside Opening LJB2TO 221.00 Cross LJB2X 259.00 Junction Box LJB2JB 247.00 Telescopic Fitting LJB2TF 144.00 Closing Plate LJB2CP 29.70 Panel Adapter LJB2A 29.00 Bracket Hanger LJB2BH 15.50 Drop Hanger LJB2DH 19.20 Extra Connector Kitb LJB2C 21.20 90o Connector LJB290C 21.20 Reducer to 2" Reducer to 4" Reducer to 6" Cut-off fittingnot Lay-in LJB2CF 84.00 Cut-off fittingLay-in LJB2CFL 150.00 Transposition FittingCCW (Str) LJB21CCW 159.00 Transposition FittingCW (Str) LJB21CW 140.00 Transposition ElbowCCW LJB290LCCW 159.00 Transposition ElbowCW LJB290LCW 159.00 Swivel fittingWireway to Wireway LJB2S 171.00 Swivel fittingWireway to Box LJB2SB 171.00 Flex FittingFeed Through LJB2FF 212.00 Barrier Kit5 ft. long w/hardware 5 pc. Barrier Pack5 ft. long 5 pc. Barrier Bracket2 compartment 5 pc. Barrier Bracket3 compartment a 10 foot straight lengths UL listed for up to 10 foot hanger spacing. b Connector kit furnished with each length and fitting. Description 4" x 4" Catalog No. LJB401 LJB402 LJB403 LJB406 LJB41 LJB42 LJB43 LJB44 LJB45 LJB410 LJB445LT LJB445LI LJB445LO LJB490LI LJB490LO LJB490LOT LJB490LT LJB4TT LJB4TO LJB4X LJB4JB LJB4TF LJB4CP LJB4A LJB4BH LJB4DH LJB4C LJB490C LJB42R LJB4CF LJB4CFL LJB41CCW LJB41CW LJB490LCCW LJB490LCW LJB4S LJB4SB LJB4FF LJB45B LJB45BKM LJB4BB2C LJB4BB3C
$ Price 76.00 81.00 85.00 99.00 110.00 135.00 168.00 201.00 227.00 439.00 182.00 182.00 182.00 182.00 182.00 182.00 182.00 238.00 273.00 318.00 289.00 155.00 32.80 39.80 18.80 25.10 27.10 27.10 97.00 100.00 166.00 177.00 177.00 182.00 182.00 184.00 184.00 299.00 34.80 79.00 23.10 49.40
6" x 6" Catalog No. LJB601 LJB602 LJB603 LJB606 LJB61 LJB62 LJB63 LJB64 LJB65 LJB610 LJB645LT LJB645LI LJB645LO LJB690LI LJB690LO LJB690LOT LJB690LT LJB6TT LJB6TO LJB6X LJB6JB LJB6TF LJB6CP LJB6A LJB6BH LJB6DH LJB6C LJB690C LJB64R LJB6CF LJB6CFL LJB61CCW LJB61CW LJB690LCCW LJB690LCW LJB6S LJB6SB LJB6FF LJB65B LJB65BKM LJB6BB2C LJB6BB3C
$ Price 95.00 100.00 106.00 123.00 135.00 184.00 230.00 280.00 332.00 637.00 234.00 234.00 234.00 234.00 234.00 234.00 234.00 285.00 328.00 383.00 351.00 177.00 43.40 47.80 25.10 39.50 29.10 29.10 132.00 124.00 190.00 234.00 211.00 234.00 234.00 254.00 254.00 385.00 70.00 120.00 80.00 99.00
8" x 8" Catalog No. LJB806 LJB81 LJB82 LJB83 LJB84 LJB85 LJB810 LJB845LT LJB845LI LJB845LO LJB890LI LJB890LO LJB890LOT LJB890LT LJB8TT LJB8TO LJB8X LJB8JB LJB8TF LJB8CP LJB8A LJB8BH LJB8DH LJB8C LJB890C LJB86R LJB8CF LJB8CFL LJB890LCCW LJB890LCW LJB8S LJB8SB LJB8FF LJB85B
$ Price 170.00 202.00 271.00 330.00 391.00 452.00 842.00 332.00 332.00 332.00 332.00 332.00 332.00 332.00 365.00 421.00 530.00 431.00 257.00 61.00 76.00 66.00 75.00 38.50 38.50 167.00 181.00 266.00 315.00 315.00 340.00 340.00 418.00 87.00
12" x 6" Catalog No. $ Price LJB12606 251.00 LJB1261 325.00 LJB1262 518.00 LJB1263 624.00 LJB1264 741.00 LJB1265 846.00 LJB12610 1523.00 LJB12645LT 410.00 LJB12690LI 410.00 LJB12690LO 410.00 LJB12690LT 410.00 LJB126TT 572.00 LJB126X 683.00 LJB126TF 464.00 LJB126CP 81.00 LJB126A 107.00 LJB126C 46.30 LJB12690C 79.00 LJB1264R 144.00 LJB1266R 144.00 LJB126CF 211.00 LJB126CFL 318.00 LJB65B 70.00
Raintight Wireway
4" x 4" 6" x 6" 8" x 8" Catalog Catalog Catalog $ Price $ Price $ Price Number Number Number 1' Length Female LDRB41F 99.00 LDRB61F 150.00 LDRB81F 226.00 1' Length Male LDRB41M 99.00 LDRB61M 150.00 LDRB81M 226.00 5' Length Female LDRB45F 198.00 LDRB65F 291.00 LDRB85F 474.00 5' Length Male LDRB45M 198.00 LDRB65M 291.00 LDRB85M 474.00 10' Length Female LDRB410F 487.00 LDRB610F 641.00 LDRB810F 641.00 10' Length Male LDRB410M 487.00 LDRB610M 641.00 LDRB810M 641.00 90o L LDRB490L 148.00 LDRB690L 198.00 LDRB890L 278.00 o 30 Sweep L LDRB430SE 302.00 LDRB630SE 431.00 LDRB830SE 546.00 Tee LDRB4T 186.00 LDRB6T 347.00 LDRB8T 317.00 Junction Box LDRB4J 257.00 LDRB6J 296.00 LDRB8J 439.00 Panel Adapter LDRB44A 87.00 LDRB66A 88.00 LDRB88A 126.00 Connectord LDRB4C 21.00 LDRB6C 31.50 LDRB8C 42.00 Closing Plate LDRB4CP 48.20 LDRB6CP 58.00 LDRB8CP 67.00 Drop Hanger LDRB4DH 23.10 LDRB6DH 32.60 LDRB8DH 63.00 Wall Hanger LDRB4WH 53.00 LDRB6WH 84.00 LDRB8WH 116.00 Reducer LDRB64R 132.00 LDRB86R 164.00 c For a continuous, straight run of wireway, alternate male and female straight sections. d Connector furnished with straight sections. Order quantity as required for fittings. 2009 Schneider Electric PE9 Discount Schedule All Rights Reserved
Raintight Trough
6" x 6" RDB61 RDB62 RDB63 RDB64 RDB65 RDB66 109.00 162.00 212.00 266.00 318.00 372.00 8" x 8" RDB82 RDB83 RDB84 RDB85 RDB86 215.00 287.00 360.00 427.00 589.00 10" x 10" RDB102 RDB103 RDB105 RDB106 289.00 382.00 527.00 632.00 12" x 12" RDB122 RDB123 RDB125 RDB126 366.00 440.00 626.00 673.00
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
Modified 1/14/11
13-3
13
WIRE MANAGEMENT
Lengths and fittings are made of 14 gauge steel with 10 gauge end flanges. Straight lengths and fittings have hinged covers with oil resistant gasket all around and are held closed with pull-down latches. All lengths and fittings are without knockouts. Type LJB lay-in Wireway is finished with ANSI-49 gray polyester powder finish over a corrosion resistant phosphate preparation. All Type LJB oiltight wireway is UL listed as steel enclosed wireway and auxiliary gutter. Conforms to NEMA Type 12.
Wall Duct
Class 5250 / Refer to Catalog 5250CT9201
www.schneider-electric.us
13
WIRE MANAGEMENT
General Notes:
1. 2. 3. 4. 5. 6. Standard construction is 14 gauge steel with gray electrodeposition paint. Alternate construction is painted aluminum. Covers and coupling devices are furnished with each device. Wire retainers are furnished with each device. Straight lengths are field cut to length. Partitions and tunnels are to be field modified and installed where required. Hangers or other mounting devices to be furnished by others.
18 x 312"
18 x 312"
Trench Duct
Horizontal Elbow
Edgewise Elbow
Tee
Cross
Reverse Ceiling Drop-out Sweep Edgewise Edgewise (Depth Adj. Elbow Cabinet Elbow 4" to 7") Connector Sweep Wall Duct To Trench Duct Adaptor
Flush Mounted
Surface Mounted Sweep Edgewise Elbow 18" to 10" Reducer Cabinet Connector End Cap Flush to Surface Adaptor Floor Trench Split Cover Vertical Elbow with Grommet
Table 13.5:
5'0" Straight Length With Cover 6"W 10"W 18"W 1'6" Straight Length With Cover 6"W 10"W 18"W Horizontal Elbow With Cover90o 6"W 10"W 18"W
Horizontal Elbow With Cover45o 6"W RWT06HE45S 10"W RWT10HE45S 18"W RWT18HE45S Edgewise Elbow With Cover 6"W RWT06EE 534.00 5.5 RWT06EES 10"W RWT10EE 534.00 7.5 RWT10EES 18"W RWT18EE 668.00 11.1 RWT18EES Tee With Cover 6"W RWT06TE 534.00 6.2 RWT06TES 10"W RWT10TE 534.00 8.5 RWT10TES 18"W RWT18TE 668.00 24.1 RWT18TES Cross With Cover 10"W RWT10XE 534.00 1.3 RWT10XES 18"W RWT18XE 668.00 1.8 RWT18XES Flanged Cabinet Connector With Cover 10"W RWT10CUC 334.00 8.0 RWT10CUCS Reverse Edgewise Elbow With Cover 6"W RWT06REE 534.00 5.8 RWT06REES 10"W RWT10REE 534.00 7.5 RWT10REES 18"W RWT18REE 668.00 11.1 RWT18REES 10.0 RWT06SSEES Sweep Edgewise Elbow With Cover 6"W RWT10SFEE 534.00 12.0 RWT10SSEES 10"W RWT18SFEE 668.00 16.5 RWT18SSEES 18"W Sweep Edgewise Elbow Cabinet Connector 10"W RWT10SWEECC 18"W RWT18SWEECC Note: All devices available in aluminum. Add A suffix to the catalog number. Contact your local Schneider Electric sales office for pricing.
13-4
PE9
Discount Schedule
Modified 1/14/11
Trench Duct
1. 2. STANDARD LENGTH of trench duct is 10 ft. Gasketed cover plates are ordered and shipped separately. FEATURES of trench duct: Trench duct width is cover plate width. Tub width is trench duct width less 1.8". Overall width (bottom flange to flange) is 3" wider than trench duct width. Standard depth is adjustable from 2-3/8" to 3-3/8". Also available as standard is depth adjustable from 3" to 4". To order, change 2 to 3. Ex. RSV063100120. Applies to trench duct, elbows, crosses, tees, and reducers. Same price as standard device. Other depths available. Tees, crosses, horizontal elbows, and reducers are shipped complete with cover plates assembled. Grey vinyl tile trim is furnished as standard. Aluminum is available when requested. All compartments over 17" wide must be supported with dividers or posts. PRICES for additions and special features: For each foot of adjustable partition, add $64.00 per foot of partition. For each 1" of depth beyond range of 3" to 4", add $32.00 per foot of trench duct. For double tile trim on two sides of cover plate, ONLY add $120.00 per foot of trench duct. For double tile trim on all four sides of cover plate, add $400.00 per foot of trench duct. For support post, add $64.00 per foot of trench duct for each row of posts required.
5'0" Partition RWTP60 100.00 Straight through tunnel for tees a 10"W RWT10ST 100.00 2.9 18"W RWT18ST 124.00 3.8 RWT10ET 150.00 3.2 90o Elbow tunnel for crosses a 10"W 18"W RWT18ET 222.00 5.1 3 compartment tunnel for tees 10"W RWT10PTE 368.00 5.0 18"W RWT18PTE 420.00 6.0 3 compartment tunnel for crosses 10"W RWT10PXE 526.00 8.0 18"W RWT18PXE 630.00 9.0 Edgewise Tee Kit 10"W RWT10ETK 150.00 1.3 18"W RWT18ETK 222.00 2.1 Sweep Edgewise Tee Kit 10"W RWT10SWET 822.00 8.0 18"W RWT18SWET 990.00 8.0 Flush to Surface Adaptor 10"W RWT10FS 418.00 11.9 18"W RWT18FS 522.00 16.4 Ceiling Drop-Out 12x12 Flush Cover 8"x8" RWTCDO 584.00 15.0 Extra Coupling Device 10"W RWT10COUP 40.80 .4 18"W RWT18COUP 64.00 .5 Extra Straight Cover30" long (Order 2 pcs. for 5 ft. of duct.) Flush 10"W RWT10SCOV 100.00 7.2 18"W RWT18SCOV 130.00 13.0 Surface 10"W RWT10SCOVS 69.00 6.1 18"W RWT18SCOVS 130.00 11.8 a Tunnels form a 3" wide compartment. Note: All devices available in aluminum. Add A suffix to the catalog number. Contact your local Schneider Electric sales office for pricing.
Table 13.7:
Reducer Coupling 18" to 10" 10" to 6" Cabinet Connector 6"W 10"W 18"W End Cap 6"W 10"W 18"W Vertical Elbows for: 6" Trench to 6" Wall Duct 12" Trench to 10" Wall Duct 12" Trench to 18" Wall Duct 18" Trench to 10" Wall Duct 18" Trench to 18" Wall Duct Sweep Trench Duct to Wall Duct Adapter (available in surface cover only) 12" Trench to 10" Wall Duct 18" Trench to 18" Wall Duct Split Cover with Grommet 12" long3"x 8" Opening Flush 6"W 10"W 18"W
Standard Depth
10.0 14.0
W + 3"
Table 13.8:
2.6 3.1 4.8 Straight Sections
All part numbers listed below are for 2 3/8"3 3/8" deep, one compartment trench with vinyl tile trims.
Surface 6"W RWT06ACPS 74.00 2.0 10"W RWT10ACPS 74.00 2.7 18"W RWT18ACPS 93.00 4.0 Dust Cover5 ft. long RWTDCOV60 150.00 5.5 Grommet100 ft. roll RWTBG100 440.00 Note: All devices available in aluminum. Add A suffix to the catalog number. Contact your local Schneider Electric sales office for pricing.
6" RSV062100120 1840.00 9" RSV092100120 1840.00 12" RSV122100120 2220.00 10'-0" 18" RSV182100120 2640.00 24" RSV242100120 3160.00 30" RSV302100120 3800.00 Covers Only (5 Plates per 10' Length)b Full Length 6" RCP0624 280.00 9" RCP0924 280.00 12" RCP1224 340.00 24" 18" RCP1824 420.00 24" RCP2424 500.00 30" RCP3024 660.00 12" RCP1212 268.00 12" 18" RCP1812 334.00 6'-0"L 12" RSV122100072 1654.00 4'-3-1/2"L 12" RSV122100051.5 1102.00 3'-3-1/2"L 12" RSV122100039.5 1102.00 2'-0"L 12" RSV122100024 550.00 1'-0"L 12" RSV122100012 550.00 12" RSV122100003.5 268.00 Factory Cut-to- 0'-3-1/2"L Length (12" Wide Only) 324" Long Coversc 224" Long Covers & 1 Wall Duct Vertical Elbowc 124" & 112" Long Cover & 1Wall Duct Vertical Elbowc 124" Long Coverc 112" Long Coverc 1Wall Duct Vertical Elbowc b c
Straight length cover plates are shipped separately and must be ORDERED SEPARATELY. Covers and/or vertical elbows for connecting trench duct to lay-in wall ductORDER SEPARATELY.
PE10
Discount Schedule
Modified 1/14/11
13-5
13
3.
WIRE MANAGEMENT
Trench Duct
13
WIRE MANAGEMENT
Table 13.9:
Table 13.10:
Item
End Closuresa
Vertical Elbows
Crossesa
Tee
RZD60 252.00
Tape for Trench Duct (180 ft. rolls) G1414 132.00 Marker for Cellular Floor G1426 20.60 a For 3" to 4" trench duct, add a 3 to end of catalog number. Note: All devices through 18" width are available in aluminum. Height is factory-set to customer specifications from 2-1/2 to 4 inches. (Non-Adjustable)
12"
U-Compartment RRV182100012RR 1670.00 5'-0" Long x 3 -1/2" Wide with Adjustable Height Sides RUC60 500.00
12"
9" and 12" wide trench 18" and 24" wide trench 30" wide trench RRV182100012LR 1670.00 Leveling Legs Support Channel Leveling Legs Not Included 5/16 x 18 x 3"
G19103
17.00
15"
RTV182100017
1754.00
G1735S
836.00
Tunnels for Trench Duct Elbows (Tee or Cross) Spacer Bar and Barrier Adjustment Gage 6" 9" 12" 18" 24" 30" RSB06 RSB09 RSB12 RSB18 RSB24 RSB30 200.00 200.00 252.00 312.00 392.00 470.00 90o tunnel for 12" trench 90o tunnel for 18" trench Straight tunnel for 12" trench Straight tunnel for 18" trench Straight through tunnel 90 elbow tunnel RSV122ET RSV182ET RSV122ST RSV182ST 200.00 280.00 116.00 118.00
Table 13.12:
Grommets
RG50 152.00
13-6
PE10
Discount Schedule
Modified 1/14/11
Table of Contents
Section 14
Transformers
General Purpose Dry Type 600 Volts and Below
EE Single-Phase Transformers EE Three-Phase Transformers EE Three-Phase, Copper Wound Transformers EE Single- and Three-Phase, Watchdog Low Temperature Rise Transformers Sealed Single- and Three-Phase Transformers Sealed Single-Phase, Export Model Transformers Sealed Single-Phase, Buck and Boost Transformers Sealed Single- and Three-Phase, Stainless Steel Enclosed Transformers Non-Ventilated Single- and Three-Phase Transformers EE NL and NLP Series Transformers EE Harmonic Mitigating Transformers Drive Isolation Transformers 14-2 14-2 14-3 14-3 14-4 14-4 14-4 14-5 14-5 14-6 14-7
TRANSFORMERS
14-7
Miscellaneous
Enclosures and Accessories Lug and Terminal Block Cover Kits; Weathershields; Wall and Ceiling Mounting Brackets; Sound Levels 14-10 14-11
Industrial Control
Square D Type T and MultiTap Transformers Square D Type TF Transformers Accessories 14-14 14-16 14-17
Transformer Disconnects
Mini Power-Zone Transformer, see page 14-12 1H729A Transformer Disconnect, see page 14-18
14-18
14-1
14
Public Law 109-58 of the Energy Policy Act of 2005 requires the manufacturing of Energy Efficient Transformers after January 1, 2007 for all General Purpose Distribution applications. Energy Efficient Transformers meet Table 4-2 of The Guide for Determining Energy Efficiency for Distribution Transformers, published by the National Electrical Manufacturers Association (NEMA TP12002), set at 24-hour average loading of 35 percent. Table 14.1:
Catalog No.
Table 14.2:
EE Three-Phase Transformers
Degree Full Capacity C Weight Taps Temp. (lbs) d Rise Enclosure de 17D 17D 18D 20D 21D 22D 24D 25D 30D 31D f 17D 17D 18D 20D 21D 22D 24D 25D 30D 31D f 17D 17D 18D 20D 21D 22D 24D 25D 30D 17D 17D 18D 20D 21D 22D 24D 25D 25D
kVA
Catalog No.
$ Price
EE Single-Phase Transformers
Full Capacity Degree C Weight Temp. (lbs) a Taps Rise Enclosure ab
kVA
$ Price
Single Phase240 X 480 V Primary 120/240 V Secondary 60 Hz; cULus Listed through 167 kVA
15 25 37.5 50 75 100 167 250 333 EE15S3H EE25S3H EE37S3H EE50S3H EE75S3H EE100S3H EE167S3H EE250S3H EE333S3H 3072.00 4151.00 5534.00 6731.00 9128.00 15091.00 17333.00 35837.00 44586.00 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 150 150 150 150 150 150 150 150 150 215 275 340 395 619 682 982 1060 1854 17D 17H 18H 18H 21D 22D 24D 25D 31D
14
TRANSFORMERS
Single Phase600 V Primary 120/240 V Secondary 60 Hz; cULus Listed through 167 kVA
15 25 37.5 50 75 100 167 250 333 EE15S3534H EE25S3534H EE37S3534H EE50S3534H EE75S3534H EE100S3534H EE167S3534H EE250S3534H EE333S3534H 3733.00 5044.00 6723.00 8177.00 11089.00 18332.00 21056.00 43535.00 50383.00 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 62.5%2+4c 150 150 150 150 150 150 150 150 150 215 275 400 450 605 795 985 1065 1865 17D 17H 18H 18H 21D 22D 24D 25D 31D
Single Phase208 V Primary 120/240 V Secondary 60 Hz; cULus Listed through 167 kVA
15 25 37.5 50 75 100 167 EE15S60H EE25S60H EE37S60H EE50S60H EE75S60H EE100S60H EE167S60H 4506.00 5866.00 7818.00 9508.00 12890.00 19613.00 24484.00 2-5%FCBN 2-5%FCBN 2-5%FCBN 2-5%FCBN 2-5%FCBN 2-5%FCBN 2-5%FCBN 150 150 150 150 150 150 150 200 275 397 420 621 795 985 17D 17H 18H 18H 21D 22D 24D
Single Phase277 V Primary 120/240 V Secondary 60 Hz; cULus Listed through 167 kVA
15 EE15S61H 4506.00 2-5%FCBN 150 225 17D 25 EE25S61H 5866.00 2-5%FCBN 150 285 17H 37.5 EE37S61H 7818.00 2-5%FCBN 150 410 18H 50 EE50S61H 9508.00 2-5%FCBN 150 460 18H 75 EE75S61H 12890.00 2-5%FCBN 150 630 21D 100 EE100S61H 19613.00 2-5%FCBN 150 695 22D 167 EE167S61H 24484.00 2-5%FCBN 150 995 24D a Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. b For enclosure styles, see Dimensions on page 14-10. c When 240 V tap is used, there will be 35% taps: 1 above and 2 below. NOTE: FCBN = full capacity below normal Lugs are furnished by customer Refer to www.squared.com/eexfmr for additional information.
Three-Phase480 V Primary 240 V Delta Secondary w/120 Center Tap 60 Hz; cULus Listed
240 Delta with 120 center taps have historically been limited to 5% capacity on the center tap. The new units from Schneider Electric offer greater limits on 120 V center tap. Limits are determined by the total transformer loading and the following formula used to size new 120 V center tap units: (240 V balanced loads) + 2.5 x (120 V loads) = kVA required 15 EE15T151HCT 5117.00 25% 150 220 17D 30 EE30T151HCT 6726.00 25% 150 295 17D 45 EE45T151HCT 8093.00 25% 150 385 18D 75 EE75T151HCT 12193.00 25% 150 590 19D 112.5 EE112T151HCT 16243.00 25% 150 635 21D 150 EE150T151HCT 21202.00 25% 150 783 22D 225 EE225T151HCT 28266.00 25% 150 1080 24D 300 EE300T151HCT 36247.00 25% 150 1355 25D 500 EE500T151HCT 50691.00 25% 150 2137 30D 750 EE750T151HCT 98020.00 25% 150 2982 31D 1000 EE1000T151HCT 149905.00 25% 150 5800 f d Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. e For enclosure styles, see Dimensions on page 14-10. f Contact factory. NOTE: Lugs are furnished by customer
14-2
PE2E
Discount Schedule
Table 14.3:
kVA
Catalog No.
$ Price
EE Watchdog Transformers
$ Price Full Capacity Taps Weight Enclosure (lbs) f fg
Catalog No.
Three Phase480 V Delta Primary 240 V Delta Secondary 60 Hz; cULus Listed
15 EE15T6H 4651.00 62.5%2+4 150 220 17D 30 EE30T6H 6114.00 62.5%2+4 150 260 17D 45 EE45T6H 7357.00 62.5%2+4 150 368 18D 75 EE75T6H 11084.00 62.5%2+4 150 585 20D 112.5 EE112T6H 14766.00 62.5%2+4 150 620 21D 150 EE150T6H 19274.00 62.5%2+4 150 835 22D 225 EE225T6H 25696.00 62.5%2+4 150 1110 24D 300 EE300T6H 32951.00 62.5%2+4 150 1350 25D 500 EE500T63H 46082.00 42.5%2+2 150 1875 30D 750 EE750T63H 89109.00 42.5%2+2 150 2965 31D 1000 EE1000T78H 143091.00 25%1+1 150 5200 c a Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. b For enclosure styles, see Dimensions Table, on page 14-10. c Contact factory. NOTE: FCBN = full capacity below normal Lugs are furnished by customer
115 C Rise Three-Phase480 V Delta Primary 208Y/120 V Secondary 60 Hz; cULus Listed
15 30 45 75 112.5 150 225 300 500 EE15T3HF EE30T3HF EE45T3HF EE75T3HF EE112T3HF EE150T3HF EE225T3HF EE300T68HF EE500T68HF 4861.00 7292.00 8777.00 13222.00 17614.00 22993.00 30652.00 39094.00 54673.00 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 2 220 368 585 620 835 980 1349 2050 2330 17D 18D 20D 21D 22D 24D 25D 30D 30D
115 C Rise Three-Phase480 V Delta Primary 208Y/120 V Secondary 60 Hz; cULus Listed. Copper Windings
15 30 45 75 112.5 150 225 300 500 EE15T3HFCU EE30T3HFCU EE45T3HFCU EE75T3HFCU EE112T3HFCU EE150T3HFCU EE225T3HFCU EE300T68HFCU EE500T68HFCU 7292.00 10938.00 13164.00 19833.00 26421.00 34491.00 45978.00 58641.00 82010.00 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 4 62.5%2 + 2 260 420 642 675 741 1050 1220 2300 2409 17D 18D 20D 20D 21D 22D 24D 30D 30D
kVA
Catalog No.
$ Price
Three-Phase480 V Delta Primary 208Y/120 V Secondary 60 Hz; cULus Listed. Copper Windings
15 EE15T3HCU 5912.00 62.5%2 + 4 150 310 17D 30 EE30T3HCU 8261.00 62.5%2 + 4 150 340 17D 45 EE45T3HCU 9943.00 62.5%2 + 4 150 418 18D 75 EE75T3HCU 14979.00 62.5%2 + 4 150 642 20D 112.5 EE112T3HCU 19955.00 62.5%2 + 4 150 725 21D 150 EE150T3HCU 26049.00 62.5%2 + 4 150 915 22D 225 EE225T3HCU 34725.00 62.5%2 + 4 150 1125 24D 300 EE300T3HCU 44531.00 62.5%2 + 4 150 1535 25D 500 EE500T68HCU 62277.00 42.5%2 + 2 150 2350 30D 750 EE750T68HCU 114674.00 42.5%2 + 2 150 3485 31D d Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. e For enclosure styles, see Dimensions Table, on page 14-10. NOTE: FCBN = full capacity below normal Lugs are furnished by customer
80 C Rise Three-Phase480 V Delta Primary 208Y/120 V Secondary 60 Hz; cULus Listed. Copper Windings
15 EE15T3HBCU 7956.00 62.5%2 + 4 260 17D 30 EE30T3HBCU 11934.00 62.5%2 + 4 418 18D 45 EE45T3HBCU 14361.00 62.5%2 + 4 642 20D 75 EE75T3HBCU 21636.00 62.5%2 + 4 725 21D 112.5 EE112T3HBCU 28823.00 62.5%2 + 4 910 21D 150 EE150T3HBCU 36962.00 62.5%2 + 4 1125 24D 225 EE225T3HBCU 45143.00 62.5%2 + 4 1425 24D 300 EE300T68HBCU 64923.00 62.5%2 + 4 2400 30D 500 EE500T68HBCU 90797.00 62.5%2 + 2 2578 30D f Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. g For enclosure styles, see Dimensions Table, on page 14-10. h When 240 V tap is used, there will be 35% taps: 1 above and 2 below. NOTE: FCBN = full capacity below normal Lugs are furnished by customer
PE2E
Discount Schedule
14-3
14
Sealed Single- and Three-Phase; Export Model; Buck and Boost Class 7400 / Refer to Catalogs 7400CT9601, 7414CT0201
www.schneider-electric.us
kVA
.05 .10 .15 .25 .50 .75 1.0 1.5 2.0 3.0 e
Three Phase480 V Delta Primary 208Y/120 V Secondary; 60 Hz; UL/cULus Listed; Copper Windings
3 6 9 15 30 3T2F 6T2F 9T2F 15T2F 30T2F 2016.00 2310.00 3088.00 4644.00 8536.00 25%FCBN 25%FCBN 25%FCBN 25%FCBN 25%FCBN 115 115 115 115 115 120 145 235 300 660 12C 12C 14C 14C 16C
50SV43A 50SV46A 206.00 50SV82A 284.00 55 4.2 1A 100SV43A 100SV46A 246.00 100SV82A 344.00 55 4.5 2A 150SV43A 150SV46A 276.00 150SV82A 386.00 55 6.2 3A 250SV43B 250SV46B 328.00 250SV82B 460.00 80 10.5 4A 500SV43B 500SV46B 420.00 500SV82B 588.00 80 13.8 5A 750SV43F 750SV46F 552.00 750SV82F 774.00 115 15.5 6A 1S43F 1S46F 676.00 1S82F 948.00 115 21.2 7A 1.5S43F 1.5S46F 830.00 1.5S82F 1162.00 115 30.1 8A 2S43F 2S46F 1072.00 2S82F 1500.00 115 39.1 9A 3S43F 3S46F 1480.00 3S82F 2072.00 115 60 g Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. f For enclosure styles, see Dimensions Table, on page 14-10. g Dimensions: 14.50 (H) x 8.60 (W) x 6.50 (D).
Three Phase480 V Delta Primary 240 V Delta Secondary; 60 Hz; UL/cULus Listed; Copper Windings
3 6 9 15 30 a b 3T5F 2016.00 25%FCBN 115 120 12C 6T5F 2310.00 25%FCBN 115 145 12C 9T75F 3088.00 42.5%FCBN 115 235 14C 15T75F 4644.00 42.5%FCBN 115 300 14C 30T75F 8536.00 42.5%FCBN 115 660 16C Not for construction. Contact your local Schneider Electric sales office or your local Schneider Electric distributor. For enclosure styles, see Dimensions Table, on page 14-10.
14-4
PE2
Discount Schedule
Enclosure ef
14
TRANSFORMERS
Non-Ventilated Transformers
$ Price
3 5 7.5 10 15 25
25% FCBN 25% FCBN 25% FCBN 25% FCBN 25% FCBN 25% FCBN
30T3HNV 150 340 19E 8090.00 62.5%2 + 4 45T3HNV 150 510 19E 12396.00 62.5%2 + 4 75T3HNV 150 1025 22E 19118.00 62.5%2 + 4 112T3HNV 25848.00 62.5%2 + 4 150 1250 24E 150T3HNV 33348.00 62.5%2 + 4 150 2000 25E 225T3HNV 50238.00 62.5%2 + 4 150 2100 30E 300T3HNV 55152.00 62.5%2 + 4 150 3950 31E Not for construction. Contact your local Schneider Electric sales office for certified prints. For enclosure styles, see Dimensions on page 14-10. When 240 V tap is used, there will be 35% taps: 1 above and 2 below.
NOTE: FCBN = full capacity below normal Lugs are furnished by customer
NOTE: FCBN = full capacity below normal Lugs are furnished by customer
Additional voltages not listed below are available. Contact your nearest Schneider Electric sales office for details. Stainless steel is painted. Table 14.10:
kVA Catalog No.
Full Degree C Capacity Temp. Taps Rise Single-Phase480 V Primary, 120/240 V Secondary 60 Hz 1 1S40F4XSS 9920.00 25% FCBN 115 2 2S40F4XSS 10380.00 25% FCBN 115 3 3S40F4XSS 10816.00 25% FCBN 115 5 5S40F4XSS 12332.00 25% FCBN 115 7.5 7S40F4XSS 13426.00 25% FCBN 115 10 10S40F4XSS 14460.00 25% FCBN 115 15 15S40F4XSS 18496.00 25% FCBN 115 25 25S40F4XSS 27720.00 25% FCBN 115 Three-Phase480 V Delta Primary, 208Y/120 V Secondary 60 Hz 3 3T2F4XSS 12676.00 25% FCBN 115 6 6T2F4XSS 13906.00 25% FCBN 115 9 9T2F4XSS 17506.00 25% FCBN 115 15 15T2F4XSS 30540.00 25% FCBN 115 30 30T2F4XSS 41612.00 25% FCBN 115 NOTE: FCBN = full capacity below normal Lugs are furnished by customer
PE2
Discount Schedule
14-5
14
TRANSFORMERS
Enclosure cd
Transformers for High Harmonic Loads; NL and NLP Class 7400 / Refer to Catalog 7400CT0601
www.schneider-electric.us
480 Delta208Y/120 Aluminum or copper windings Electrostatic shield Class 220 insulation Double size neutral terminal for additional customer neutral cables Additional coil capacity to compensate for higher non-linear load loss cULus Listed EE NL and NLP Series Transformers
Weight (lbs) a Enclosure ab
kVA
Catalog No.
$ Price
Taps
Weight (lbs) a
NL Series for Typical Non-Linear Load Service K-4 RatedCopper Windings; 150 C Rise
15 30 45 75 112.5 150 225 300 EE15T3HISCUNL EE30T3HISCUNL EE45T3HISCUNL EE75T3HISCUNL EE112T3HISCUNL EE150T3HISCUNL EE225T3HISCUNL EE300T68HISCUNL 8838.00 13258.00 15957.00 24040.00 32025.00 41806.00 58073.00 80447.00 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 260 395 730 640 935 1300 1450 2450 17D 18D 20D 20D 22D 24D 24D 25D
Table 14.12:
kVA
Catalog No.
$ Price
Taps
NLP Series for More Severe Non-Linear Load ServiceK-13 RatedCopper Windings; 150 C Rise
15 30 45 75 112.5 150 225 300 EE15T3HISCUNLP EE30T3HISCUNLP EE45T3HISCUNLP EE75T3HISCUNLP EE112T3HISCUNLP EE150T3HISCUNLP EE225T3HISCUNLP EE300T68HISCUNLP 9744.00 14618.00 17594.00 26506.00 35310.00 46094.00 61448.00 81560.00 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 260 430 730 640 985 1135 1477 2650 17D 18D 20D 20D 22D 24D 25D 30D
NL Series for Typical Non-Linear Load Service K-4 RatedAluminum Windings; 150 C Rise
62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 42.5% 2+2
NL Series for Typical Non-Linear Load Service K-4 RatedCopper Windings; 115 C Rise
15 30 45 75 112.5 150 225 300 EE15T3HFISCUNL EE30T3HFISCUNL EE45T3HFISCUNL EE75T3HFISCUNL EE112T3HFISCUNL EE150T3HFISCUNL EE225T3HFISCUNL EE300T68HFISCUNL 8751.00 13127.00 15801.00 23799.00 31706.00 41388.00 57584.00 79769.00 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 260 395 730 640 935 1300 1450 2450 17D 18D 20D 20D 22D 24D 25D 25D
NLP Series for More Severe Non-Linear Load ServiceK-13 RatedAluminum Windings; 150 C Rise
15 30 45 75 112.5 150 225 300 500 EE15T3HISNLP EE30T3HISNLP EE45T3HISNLP EE75T3HISNLP EE112T3HISNLP EE150T3HISNLP EE225T3HISNLP EE300T68HISNLP EE500T68HISNLP 5976.00 8963.00 10789.00 17876.00 21650.00 28261.00 38507.00 51295.00 71277.00 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 42.5% 2+2 261 365 415 535 750 755 775 2350 3150 17D 18D 20D 21D 22D 24D 25D 30D 31D
NLP Series for More Severe Non-Linear Load ServiceK-13 RatedCopper Windings; 115 C Rise
15 EE15T3HFISCUNLP 9954.00 62.5% 2+4 260 17D 30 EE30T3HFISCUNLP 14931.00 62.5% 2+4 430 18D 45 EE45T3HFISCUNLP 17972.00 62.5% 2+4 730 20D 75 EE75T3HFISCUNLP 27072.00 62.5% 2+4 640 20D 112.5 EE112T3HFISCUNLP 36065.00 62.5% 2+4 985 22D 150 EE150T3HFISCUNLP 47079.00 62.5% 2+4 1135 24D 225 EE225T3HFISCUNLP 64146.00 62.5% 2+4 1477 25D 300 EE300T68HFISCUNLP 85449.00 42.5% 2+2 2650 30D a Not for construction. Contact your local Schneider Electric sales office for certified prints. b For enclosure styles, see Dimensions Table, page 14-10. NOTE: Available with optional 80 C temperature rise via product selector. Lugs are furnished by customer.
NL Series for Typical Non-Linear Load Service K-4 RatedAluminum Windings; 115 C Rise
15 30 45 75 112.5 150 225 300 500 EE15T3HFISNL EE30T3HFISNL EE45T3HFISNL EE75T3HFISNL EE112T3HFISNL EE150T3HFISNL EE225T3HFISNL EE300T68HFISNL EE500T68HFISNL 5834.00 8751.00 10533.00 15866.00 21137.00 27592.00 38389.00 53179.00 73483.00 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 42.5% 2+2 256 320 515 535 800 1110 1349 1750 2295 17D 18D 20D 21D 22D 24D 25D 30D 31D
NLP Series for More Severe Non-Linear Load ServiceK-13 RatedAluminum Windings, 115 C Rise
15 30 45 75 112.5 150 225 300 500 EE15T3HFISNLP EE30T3HFISNLP EE45T3HFISNLP EE75T3HFISNLP EE112T3HFISNLP EE150T3HFISNLP EE225T3HFISNLP EE300T68HFISNLP EE500T68HFISNLP 6636.00 9954.00 11981.00 18048.00 24043.00 31386.00 42764.00 56966.00 79157.00 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 62.5% 2+4 42.5% 2+2 42.5% 2+2 256 375 500 560 800 1110 1335 2350 3200 17D 18D 20D 21D 22D 24D 25D 30D 31D
14-6
PE2E
Discount Schedule
Enclosure ab
14
TRANSFORMERS
Transformers for High Harmonic Loads; DIT; HMT Class 7400 / Refer to Catalog 7400CT0301 Drive Isolation Transformers
Special design considerations must be made for the requirements of both adjustable frequency and dc motor drive power isolation. Allowance for high surge, harmonic and offset currents are taken into account in the design of Square D brand drive isolation transformers. Drive isolation transformers are not shielded isolation transformers, but act to lessen transient generation into the supply power and act as a buffer for SCR current surges. Table 14.14:
kVA
New!
Catalog No.
Catalog No.
0 Phase Shift, 130 C Rise 15 HM15T208NCU 12670.00 62.5% 2+4 310 17D 30 HM30T208NCU 19416.00 62.5% 2+4 340 17D 45 HM45T208NCU 23364.00 62.5% 2+4 418 18D 75 HM75T208NCU 35204.00 62.5% 2+4 642 20D 112.5 HM112T208NCU 46900.00 62.5% 2+4 725 21D 150 HM150T208NCU 61226.00 62.5% 2+4 915 22D 225 HM225T208NCU 81616.00 62.5% 2+4 1125 24D 300 HM300T208NCU 104664.00 62.5% 2+4 1535 25D +30 Phase Shift, 130 C Rise 15 HM15T255NCU 12670.00 35% 1+3 310 17D 30 HM30T255NCU 19416.00 35% 1+3 340 17D 45 HM45T255NCU 23364.00 35% 1+3 418 18D 75 HM75T255NCU 35204.00 35% 1+3 642 20D 112.5 HM112T255NCU 46900.00 35% 1+3 725 21D 150 HM150T255NCU 61226.00 35% 1+3 915 22D 225 HM225T255NCU 81616.00 35% 1+3 1125 24D 300 HM300T255NCU 104664.00 35% 1+3 1535 25D +15 Phase Shift, 130 C Rise 15 HM15T251NCU 12670.00 62.5% 2+4 310 17D 30 HM30T251NCU 19416.00 62.5% 2+4 340 17D 45 HM45T251NCU 23364.00 62.5% 2+4 418 18D 75 HM75T251NCU 35204.00 62.5% 2+4 642 20D 112.5 HM112T251NCU 46900.00 62.5% 2+4 725 21D 150 HM150T251NCU 61226.00 62.5% 2+4 915 22D 225 HM225T251NCU 81616.00 62.5% 2+4 1125 24D 300 HM300T251NCU 104664.00 42.5% 2+2 1535 25D -15 Phase Shift, 130 C Rise HM15T259NCU 12670.00 62.5% 2+4 310 17D 15 30 HM30T259NCU 19416.00 62.5% 2+4 340 17D 45 HM45T259NCU 23364.00 62.5% 2+4 418 18D 75 HM75T259NCU 35204.00 62.5% 2+4 642 20D 112.5 HM112T259NCU 46900.00 62.5% 2+4 725 21D 150 HM150T259NCU 61226.00 62.5% 2+4 915 22D 225 HM225T259NCU 81616.00 62.5% 2+4 1125 24D 300 HM300T259NCU 104664.00 42.5% 2+2 1535 25D a Not for construction. Contact your local Schneider Electric sales office for certified prints. b For enclosure styles, see Dimensions Table, page 14-10. NOTE: Lugs are furnished by customer.
PE2E
PE2
Discount Schedule
14-7
14
TRANSFORMERS
Three-Phase Transformers
Catalog Weight Enclosurea $ Price No. (lbs) See 14-10 oC Rise 2.4 kV and 5 kV Voltage Class 60 Hz 150 112.5 112T( )H 42603.00 1400 36D 150 150T( )H 52338.00 1600 37D 225 225T( )H 70422.00 1900 37D 300 300T( )H 84972.00 2100 37D 500 500T( )H 99231.00 3200 38D 750 b 750T( )H 124257.00 3900 39F 1000 b 1000T( )H 154230.00 7400 40F 1500 b 1500T( )H 185367.00 9000 40F 2000 b 2000T( )H 212721.00 10900 41F 2500 b 2500T( )H 257244.00 12200 34F 15 kV Voltage Class 60 Hz 150 oC Rise 112.5 112T( )H 48822.00 2000 30D 150 150T( )H 60033.00 2200 30D 225 225T( )H 81771.00 2800 31D 300 300T( )H 95448.00 3300 31D 500 500T( )H 116400.00 5000 32F 750 b 750T( )H 138225.00 6000 33F 1000 b 1000T( )H 175764.00 7400 33F 1500 b 1500T( )H 201081.00 9000 33F 2000 b 2000T( )H 235710.00 10900 34F 2500 b 2500T( )H 272958.00 12200 34F 3000 b 3000T( )H 351528.00 15400 35F a Enclosures for indoor use only. Letters in parenthesis refer to enclosure styles on page 14-10. Transformers suitable for outdoor use are available on special order. Adding a weather shield will not make medium voltage transformer suitable for outdoor use. b Dimensions and prices listed for 480 volt secondary only. For 240 V or 208 V, contact your local Schneider Electric sales office. NOTE: Lugs are furnished by customer
Catalog Weight Enclosure c kVA $ Price No. (lbs) See 14-10 o C Rise 2.4 kV Voltage Class 60 Hz 150 167 167S( )H 45444.00 1500 37D 250 250S( )H 59253.00 2200 38D 333 333S( )H 72783.00 3000 38D o C Rise 5 kV Voltage Class 60 Hz 150 167 167S( )H 48777.00 1500 37D 250 250S( )H 63312.00 2200 38D 333 333S( )H 77478.00 3200 38D oC Rise 15 kV Voltage Class 60 Hz 150 167 167S( )H 56136.00 2400 38D 250 250S( )H 72705.00 3400 38D 333 333S( )H 86835.00 5000 43F c Enclosures for indoor use only. Letters in parenthesis refer to enclosure styles on page 14-10. Transformers suitable for outdoor use are available on special order. Adding a weather shield will not make medium voltage transformer suitable for outdoor use. NOTE: Lugs are furnished by customer
14
TRANSFORMERS
Table 14.18:
kV Class 2.4 30 kV BIL 5 30 kV BIL
Table 14.16:
kV Class 2.4 30 kV BIL
Special Notes
1. Distribution class lightning arresters are recommended as good practice, but are not included in the above prices. Arrester addition may affect dimensions. Contact your nearest Schneider Electric sales office. 2. For 15 kV transformers requiring bottom entrance or exit, a separate compartment is required for adequate termination space and clearance. Transformers 1500 kVA and above with top entrance or exit may require a separate compartment to provide adequate wiring space. Contact your nearest Schneider Electric sales office for special requirements. 3. If the transformer requires a 94-inch high enclosure for a switchgear line-up, or if a special enclosure is required, contact your nearest Schneider Electric sales office. 4. For 95 kV BIL, consult your nearest Schneider Electric sales office. (May affect dimensions.)
5 30 kV BIL
15 60 kV BIL
Ordering Information
To complete the three- or single-phase catalog numbers on this page: 1. Select the voltage you require from the charts above. 2. Insert the voltage code number in place of the ( ) in the catalog number.
Example 1: 1000 kVA, 3, 60 Hz, 150 C temp. rise, 60 kV BIL, NEMA sound level, ventilated indoor enclosure, 13.2 kV delta 480Y/277, with 2-2.5% full capacity taps. 2AN and 2BN = 1000T51H . Example 2: 750 KVA 3, 60 Hz, 80 C temp. rise, 60 kV BIL, NEMA sound level, ventilated indoor enclosure, 4160 V Delta, 480Y/277, 2-2.5% full capacity taps. 2AN and 2BN = Part number 750T19HB. Add 20% to listed price. Example 3: 167 kVA, 2400/4160Y-120/240, 1 60 Hz unit is 167S13H. The unit would be supplied with 22.5% above and 22.5% full capacity below normal taps on the primary.
14-8
PE6D
Discount Schedule
New!
Ordering Information
To complete the three- or single-phase catalog numbers on this page: 1. Select the voltage you require from the charts above. 2. Insert the voltage code number (from page 14-8) in place of the ( ) in the catalog number.
Example 1: 1000 kVA, 3, 60 Hz, 150 C temp. rise, 60 kV BIL, NEMA sound level, ventilated indoor enclosure, 13.2 kV delta 480Y/277, with 2-2.5% full capacity taps. 2AN and 2BN = 1000T51H . Example 2: 750 KVA 3, 60 Hz, 80 C temp. rise, 60 kV BIL, NEMA sound level, ventilated indoor enclosure, 4160 V Delta, 480Y/277, 2-2.5% full capacity taps. 2AN and 2BN = Part number 750T19HB. Add 20% to listed price. Example 3: 167 kVA, 2400/4160Y-120/240, 1 60 Hz unit is 167S13H. The unit would be supplied with 22.5% above and 22.5% full capacity below normal taps on the primary.
EE Three-Phase Transformers
$ Price Weight (lbs) Enclosure See 14-10 36D 37D 37D 37D 38D 39F 40F 40F 42F 34F 38D 38D 38D 45D 44F 39F 40F 40F 41F 42F 42F
Catalog No.
2.4 kV and 5 kV Voltage Class, 60 Hz, 150 C Rise 112.5 EE112T( )H 51125.00 1540 150 EE150T( )H 62805.00 1760 225 EE225T( )H 84500.00 2090 300 EE300T( )H 101965.00 2310 500 EE500T( )H 119077.00 3520 750 EE750T( )H 149110.00 4290 1000 EE1000T( )H 185080.00 8140 1500 EE1500T( )H 222440.00 9900 2000 EE2000T( )H 255265.00 11990 2500 EE2500T( )H 308692.00 13420 15 kV Voltage Class, 60 Hz ,150 C Rise 112.5 EE112T( )H 58586.00 2200 150 EE150T( )H 72309.00 2420 225 EE225T( )H 98125.00 3080 300 EE300T( )H 137445.00 3630 500 EE500T( )H 139650.00 5500 750 EE750T( )H 165870.00 6600 1000 EE1000T( )H 210915.00 8140 1500 EE1500T( )H 241298.00 9900 2000 EE2000T( )H 282852.00 11990 2500 EE2500T( )H 327549.00 13420 3000 EE3000T( )H 421833.00 16940 NOTE: Lugs are furnished by customer See page 14-8 for voltage codes and Special Notes.
Table 14.21:
Single Phase
New!
KVA Efficiency % KVA Efficiency % 10 98.67 15 98.36 15 98.76 30 98.62 25 98.91 45 98.76 37.5 99.01 75 98.91 50 99.08 112.5 99.01 75 99.17 150 99.08 100 99.23 225 99.17 167 99.25 300 99.23 250 99.32 500 99.25 333 99.36 750 99.32 500 99.42 1000 99.36 667 99.46 1500 99.42 833 99.49 2000 99.46 2500 99.49 All Efficiency values are at 50% of nameplate-rated load, determined according to the DOE Test Procedure 10 CFR 431, Subpart K, Appendix A.
Table 14.22:
EE Single-Phase Transformers
$ Price Weight (lbs) Enclosure See 14-10 37D 38D 38D 37D 38D 38D 38D 38D 43F BIL kVA
Standard Levels for Medium Voltage Dry Type Distribution Transformers, Tabular Form b
Three Phase BIL kVA Efficiency (%) (in kV) Efficiency (%) (in kV)
Single Phase
Catalog No.
2.4 kV Voltage Class, 60 Hz, 150 C Rise 167 EE167S( )H 45444.00 1650 250 EE250S( )H 59253.00 2420 333 EE333S( )H 72783.00 3300 5 kV Voltage Class, 60 Hz, 150 C Rise 167 EE167S( )H 48777.00 1650 250 EE250S( )H 63312.00 2420 333 EE333S( )H 77478.00 3520 15 kV Voltage Class, 60 Hz, 150 C Rise 167 EE167S( )H 56136.00 2640 250 EE250S( )H 72705.00 3740 333 EE333S( )H 86835.00 5500 NOTE: Lugs are furnished by customer See page 14-8 for voltage codes and Special Notes.
20-45 46-95 96 20-45 46-95 96 15 98.1 97.86 15 97.5 97.18 25 98.33 98.12 30 97.9 97.63 37.5 98.49 98.3 45 98.1 97.86 50 98.6 98.42 75 98.33 98.12 75 98.73 98.57 98.53 112.5 98.49 98.3 100 98.82 98.67 98.63 150 98.6 98.42 167 98.96 98.83 98.8 225 98.73 98.57 98.53 250 99.07 98.95 98.91 300 98.82 98.67 98.63 333 99.14 99.03 98.99 500 98.96 98.83 98.8 500 99.22 99.12 99.09 750 99.07 98.95 98.91 667 99.27 99.18 99.15 1000 99.14 99.03 98.99 833 99.31 99.23 99.2 1500 99.22 99.12 99.09 2000 99.27 99.18 99.15 2500 99.31 99.23 99.2 b All Efficiency values are at 50% of nameplate-rated load, determined according to the DOE Test Procedure 10 CFR 431, Subpart K, Appendix A. NOTE: BIL = Basic Impulse Level
PE6D
Discount Schedule
14-9
14
TRANSFORMERS
The Department of Energy (DOE) has determined that energy conservation standards for MV Distribution Transformers will result in significant conservation of energy, so they have passed the DOE 10 CFR Part 431 Energy Conservation program for Commercial Equipment. Starting January 1, 2010, all medium voltage distribution transformers with ratings of 2500 KVA and below, 34.5 KV primary and below, and 600 V class secondary voltages must meet minimum efficiency requirements. Liquid Filled Padmounts, Liquid Filled Substations, Dry Type VPI, and Power Cast products shipped after January 1, 2010 will all be included. The minimum efficiency tables are listed below. Please contact your nearest Schneider Electric Sales Office for more information.
Miscellaneous
Enclosures; Accessories
Class 7400
www.schneider-electric.us
Height
In.
mm
In.
mm
In.
mm
18 19 20 21 22 23 24
25 26 28 29 30 31 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 a b c d e
A 5.00 127 4.47 114 3.44 87 Wall b c 105 A 5.50 140 4.47 114 3.44 87 Wall b c 105 A 5.00 127 4.85 123 3.75 95 Wall b c 105 A 5.50 140 5.23 133 4.06 103 Wall b c 130 A 6.19 157 6.19 157 4.69 119 Wall b c 130 A 6.69 170 6.19 157 4.69 119 Wall b c 180 A 8.13 270 6.94 176 5.31 135 Wall b c 180 A 8.25 210 8.68 220 6.56 167 Wall b c 180 A 9.56 243 8.68 220 6.56 167 Wall b c 180 A 10.50 267 8.62 219 6.50 165 Wall b c 180 A 12.56 319 8.62 219 6.50 165 Wall b c 180 C 13.50 343 14.75 375 9.00 229 Wall b c 180 B 14.75 375 9.75 248 11.75 298 Wall b c 180 C 14.75 375 19.10 485 12.25 311 Wall b c 180 B 20.00 508 15.00 381 13.50 343 Wall b c 180 C 22.00 559 25.00 635 13.50 343 Wall b c 180 D 27.00 686 20.00 508 16.00 406 Floor WS363 WMB361362 CMB363 220 E 27.00 686 20.00 508 16.00 406 Floor e WMB361362 CMB363 220 H 37.00 940 20.00 508 16.00 406 Floor WS363 WMB361362 CMB363 220 D 30.00 762 20.00 508 20.00 508 Floor WS363 WMB363364 CMB363 220 E 30.00 762 20.00 508 20.00 508 Floor e WMB363364 CMB363 220 H 37.00 940 20.00 508 20.00 508 Floor WS363 WMB363364 CMB363 220 D 30.00 762 30.00 762 20.00 508 Floor WS364 WMB363364 CMB364 220 E 30.00 762 30.00 762 20.00 508 Floor e WMB363364 CMB364 220 D 37.00 940 30.00 762 20.00 508 Floor WS364 WMB363364 CMB364 220 E 37.00 940 30.00 762 20.00 508 Floor e WMB363364 CMB364 220 D 37.00 940 30.00 762 24.00 610 Floor WS364 CMB364 220 E 37.00 940 30.00 762 24.00 610 Floor e CMB364 220 D 43.75 1111 32.00 813 27.00 686 Floor WS380 CMB380 220 E 43.75 1111 32.00 813 27.00 686 Floor e CMB380 220 E 48 1219 48 1219 29.5 749 Floor e 220 D 49.5 1257 35 889 28.5 724 Floor WS381 CMB381 220 E 49.5 1257 35 889 28.5 724 Floor Note 5 CMB381 220 D 49.5 1257 41 1041 32 813 Floor WS382 220 E 49.5 1257 41 1041 32 813 Floor e 220 D 57.5 1461 41 1041 32 813 Floor WS382 220 D 60 1524 56 1422 36 914 Floor WS370A 220 E 60 1524 56 1422 36 914 Floor e 220 D 68 1727 56 1422 36 914 Floor WS370A 220 D 71 1803 48 1219 36 914 Floor WS383 220 D 74 1880 56 1422 40.5 1029 Floor WS384 220 E 60 1524 56 1422 36 914 Floor e 220 F 91.5 2388 56 1422 54 1372 Floor d 220 F 94 2388 72 1829 54 1372 Floor d 220 F 94 2388 84 2134 54 1372 Floor d 220 F 94 2388 96 2438 54 1372 Floor d 220 D 40.5 1031 36 916 21.75 553 Floor d 220 D 51.5 1310 40.5 1031 26.5 674 Floor d 220 D 66 1679 50.5 1285 32 814 Floor d 220 F 90 2290 80 2036 50 1272 Floor d 220 F 90 2290 90 2290 50 1272 Floor d 220 F 100 2545 100 2545 60 1527 Floor d 220 F 108 2748 108 2748 60 1527 Floor d 220 F 90 2290 64 1628 44 1120 Floor d 220 F 90 2290 72 1832 50 1272 Floor d 220 D 80 2036 64 1628 44 1120 Floor d 220 These dimensions are not for construction. Contact your local Schneider Electric sales office for certified prints. Transformer is NEMA 3R Standard. Weathershield not required for outdoor use. Wall mounting brackets are a standard part of transformer enclosure. Accessory not required. Special outdoor construction required for NEMA 3R applications. Contact your local Schneider Electric sales office for details. Indoor/outdoor enclosure standard. Weathershield not required.
14
TRANSFORMERS Style FNEMA 1 Rated
NOTE: Wall mounting brackets can only be used with units weighing no more than 700 lbs. Ceiling mounting brackets can only be used with units weighing no more than 1200 lbs. Weathershields are only available for units 600 Volts and below. For 2.4 kV, 5 kV, and 15 kV units suitable for outdoor use, contact the factory.
14-10
Miscellaneous
www.schneider-electric.us
Lugs; Terminal Block Covers; Weathershields; Mounting Brackets Class 7400 / Refer to Catalog 7400CT0501
Lug Kits
$ Price Per Kit Lugs Per Kit Wire Range Cap Screws Wire Range
Lugs are not supplied with transformer units. They must be purchased separately. Table 14.24:
Catalog No. a
Current Range Bonding Lugs per Kit Single-Phase Primary, Single-Phase Secondary, Three-Phase Delta Primary, Three-Phase Delta Secondary DASKP100 28.00 3 1/014 STR. 1/4 x 1 in Up to 100 A DASKP250 51.00 3 350 kcmil6 STR. 1/4 x 1 in 101 to 250 A 600 kcmil4 STR. DASKP400 91.00 3 1/4 x 1 in 201 to 400 A (2) 250 kcmil1/0 STR. Not applicable 600 kcmil4 STR. DASKP600 182.00 6 1/4 x 1 in 601 to 800 A (2) 250 kcmil1/0 STR. DASKP1000 272.00 9 600 kcmil2 STR. 3/8 x 2 in 601 to 800 A DASKP1200 363.00 12 600 kcmil2 STR. 3/8 x 2 in 801 to 1200 A Single-Phase Primary and Secondary, Three-Phase Wye Secondary, Three-Phase Delta with Center Tap DASKS100 47.00 5 1/014 STR. 1/4 x 1 in Up to 100 A 1 DASKS250 109.00 5 350 kcmil6 STR. 1/4 x 1 in 101 to 250 A 1 600 kcmil4 STR. DASKS400 169.00 5 1/4 x 1 in 201 to 400 A 1 (2) 250 kcmil1/0 STR. DASKS600 320.00 10 600 kcmil2 STR. 1/4 x 1 in 601 to 800 A 1 DASKS1000 472.00 15 600 kcmil2 STR. 3/8 x 2 in 601 to 800 A 1 DASKS1200 622.00 20 600 kcmil2 STR. 3/8 x 2 in 801 to 1200 A 1 DASKS2000 774.00 25 600 kcmil2 STR. 3/8 x 2 in 1201 to 2000 A 1 a Subject to minimum billing and freight charges when not ordered with transformer.
Not applicable
214 STR. 214 STR. 1/014 STR. 250 kcmil6 STR. 250 kcmil6 STR. 250 kcmil6 STR. 350 kcmil6 STR.
Table 14.25:
VERSAtile Compression Lugs and Mechanical Set-Screw TypesUL Listed Lugs AL9CU (90 C Rated)
$ Price Per Kit 261.00 424.00 2407.00 2619.00 Qty. 8 5 13 3 26 34 Catalog No. VCEL02114S1 VCEL030516H1 VCEL030516H1 VCEL030516H1 VCEL07512H1 VCEL07512H1 Qty. 8 1 8 8 3 16 21 Cap Screws 1/4 x 1 in 1/4 x 2 in 1/4 x 1 in 1/4 x 2 in 1/4 x 3/4 in 3/8 x 2 in 3/8 x 2 in
Transformer kVA Sizes Kit Catalog No. 1537 1 1545 3 5075 1 75112 3 100167 1 150300 3 500 3 VCELSK1 VCELSK2 VCELSK3 VCELSK4
#4300 kcmil #4300 kcmil 500750 kcmil Al 500 kcmil Cu 500750 kcmil Al 500 kcmil Cu
Table 14.26:
Table 14.27:
Catalog No. WS363 WS364 WS370A WS380
Weathershields
b c
WS381 682.00 CMB363 300.00 WS382 1160.00 CMB364 300.00 WS383 2184.00 CMB380 748.00 WS384 2464.00 CMB381 748.00 Wall mounting brackets may be prohibited in some California areas requiring 12-inch spacing from wall. Wall mounting brackets can only be used with units weighing no more than 700 lbs. Base channels are supplied for ceiling mounting; trapeze hangers must be furnished by customer. Ceiling mounting brackets can only be used with units weighing no more than 1200 lbs.
Table 14.28:
Sound Levels
NEMA Standard Sound Level 40 dB 45 dB 50 dB 55 dB 60 dB 62 dB 64 dB
Square D brand transformers meet NEMA standards for sound level. Lower sound levels are available at an additional charge.
PE2E
PE2
Discount Schedule
14-11
14
Fingersafe terminal block cover kits for encapsulated transformers can be used to meet touch-safe requirements of EN60-204.
TRANSFORMERS
Terminal Lugs
Hardware Included
Mini Power-Zone
Class 7440 / Refer to Brochure 7440BR9401
www.schneider-electric.us
14
TRANSFORMERS
Output Single-Phase Panel Rated 120/240 5 MPZ5S40F 3890.00 480 25% FCBN 7.5 MPZ7S40F 4542.00 480 25% FCBN 10 MPZ10S40F 4938.00 480 25% FCBN 15 MPZ15S40F 6410.00 480 25% FCBN 25 MPZ25S40F 9560.00 480 25% FCBN Output Three-Phase Panel Rated 208Y/120 15 22.5 30 a
MPZ15T2F 10088.00 480 25% FCBN 710 44.6 1133 27.4 696 13.6 345 40 MPZ22T2F 12502.00 480 25% FCBN 725 44.6 1133 27.4 696 13.6 345 70 MPZ30T2F 15338.00 480 25% FCBN 755 44.6 1133 27.4 696 13.6 345 90 Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints.
60 80 100
24 or 8
Table 14.30: With QO Plug-On Feeder Circuit Breakers Interrupting Rating: 25 kAIC
kVA Catalog No. $ Price Input Voltage Full Capacity Taps Dimensions b Weight (lbs) H In. 12.0 12.0 12.0 17.4 17.4 W mm 305 305 305 442 442 In. 11.9 11.9 11.9 13.5 13.5 D Primary Secondary Main Circuit Main Circuit Breaker Breaker mm Rating (A) Rating (A) 302 302 302 343 343 15 20 30 60 100 30 40 60 80 125 Feeder Breakers Max. No. 1- or 2-Pole Max. A 20 30 40 60 100 Max. A 40 60 80
In. mm Output Single-Phase Panel Rated 120/240Interrupting Rating 25 AIC 5 MPZ5S40F25K 6197.00 480 25% FCBN 175 32.7 831 7.5 MPZ7S40F25K 6849.00 480 25% FCBN 200 32.7 831 10 MPZ10S40F25K 7245.00 480 25% FCBN 215 32.7 831 15 MPZ15S40F25K 8717.00 480 25% FCBN 390 42.9 1090 25 MPZ25S40F25K 11867.00 480 25% FCBN 390 42.9 1090 Output Three-Phase Panel Rated 208Y/120Interrupting Rating 25 AIC 15 22.5 30 b
MPZ15T2F25K 12395.00 480 25% FCBN 710 44.6 1133 27.4 696 13.6 345 40 MPZ22T2F25K 14809.00 480 25% FCBN 725 44.6 1133 27.4 696 13.6 345 70 MPZ30T2F25K 17645.00 480 25% FCBN 755 44.6 1133 27.4 696 13.6 345 90 Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints.
60 80 100
24 or 8
Table 14.31: With QOB Bolt-On Feeder Circuit Breakers Interrupting Rating: 18 kAIC
kVA Catalog No. $ Price Input Voltage Full Capacity Taps Dimensions c Weight (lbs) In. 175 200 215 390 390 41.0 41.0 41.0 51.0 51.0 H mm 1041 1041 1041 1295 1295 In. 12.0 12.0 12.0 17.4 17.4 W mm 305 305 305 442 442 In. 11.9 11.9 11.9 13.5 13.5 D Primary Secondary Main Circuit Main Circuit Breaker Breaker mm Rating (A) Rating (A) 302 302 302 343 343 15 20 30 60 100 30 40 60 80 125 Feeder Breakers Max. No. 1- or 2-Pole Max. A 20 30 40 60 100 Max. A 40 60 80
Output Single-Phase Panel Rated 120/240 5 MPZB5S40F 4860.00 480 25% FCBN 7.5 MPZB7S40F 5680.00 480 25% FCBN 10 MPZB10S40F 6170.00 480 25% FCBN 15 MPZB15S40F 8010.00 480 25% FCBN 25 MPZB25S40F 11950.00 480 25% FCBN Output Three-Phase Panel Rated 208Y/120
15 MPZB15T2F 12610.00 480 25% FCBN 710 48.6 1234 27.4 696 13.6 345 40 22.5 MPZB22T2F 15624.00 480 25% FCBN 725 48.6 1234 27.4 696 13.6 345 70 30 MPZB30T2F 19176.00 480 25% FCBN 755 48.6 1234 27.4 696 13.6 345 90 c Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints. NOTE: Other input voltages are available. Contact local Schneider Electric office for part numbers and quotations. Input voltages that are available: 600, 240, and 208, single- and three-phase. FCBN = full capacity below normal
60 80 100
24 or 8
14-12
PE2
Discount Schedule
Mini Power-Zone
Class 7440 / Refer to Brochure 7440BR9401
Table 14.32: With QOB Bolt-On Feeder Circuit Breakers Interrupting Rating: 25 kAIC
Dimensions a kVA Catalog No. $ Price Input Voltage Full Capacity Taps Weight (lbs) In. 175 200 215 390 390 41.0 41.0 41.0 51.0 51.0 H mm 1041 1041 1041 1295 1295 In. 12.0 12.0 12.0 17.4 17.4 W mm 305 305 305 442 442 In. 11.9 11.9 11.9 13.5 13.5 D Secondary Primary Main Main Circuit Circuit Breaker Breaker mm Rating (A) Rating (A) 302 302 302 343 343 15 20 30 60 100 30 40 60 80 125 Feeder Breakers Max. No. 1- or 2-Pole Max. A
Output Single-Phase Panel Rated 120/240 5 MPZB5S40F25K 7168.00 480 25% FCBN 7.5 MPZB7S40F25K 7987.00 480 25% FCBN 10 MPZB10S40F25K 8478.00 480 25% FCBN 15 MPZB15S40F25K 10317.00 480 25% FCBN 25 MPZB25S40F25K 14257.00 480 25% FCBN Output Three-Phase Panel Rated 208Y/120
15 MPZB15T2F25K 14917.00 480 25% FCBN 710 48.6 1234 27.4 696 13.6 345 40 22.5 MPZB22T2F25K 17931.00 480 25% FCBN 725 48.6 1234 27.4 696 13.6 345 70 30 MPZB30T2F25K 21483.00 480 25% FCBN 755 48.6 1234 27.4 696 13.6 345 90 a Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints. NOTE: FCBN = full capacity below normal
60 80 100
24 or 8
20 30 40 60 100 Max. A 40 60 80
Table 14.33: With QOB Bolt-On Feeder Circuit Breakers Interrupting Rating: 65 kAIC
kVA Catalog No. $ Price Input Voltag e Full Capacity Taps Dimensions b Weigh t (lbs) In. 175 200 215 390 390 41.0 41.0 41.0 51.0 51.0 H mm 1041 1041 1041 1295 1295 In. 12.0 12.0 12.0 17.4 17.4 W mm 305 305 305 442 442 In. 11.9 11.9 11.9 13.5 13.5 D Primary Secondary Main Circuit Main Circuit Breaker Breaker mm Rating (A) Rating (A) 302 302 302 343 343 15 20 30 60 100 30 40 60 80 125 Feeder Breakers Max. No. 1- or 2-Pole Max. A 20 30 40 60 100 Max. A 40 60 80
Output Single Phase Panel Rated 120/240 5 MPZB5S40F65K 7889.00 480 25% FCBN 7.5 MPZB7S40F65K 8708.00 480 25% FCBN 10 MPZB10S40F65K 9799.00 480 25% FCBN 15 MPZB15S40F65K 11038.00 480 25% FCBN 25 MPZB25S40F65K 14978.00 480 25% FCBN Output Three-Phase Panel Rated 208Y/120
15 MPZB15T2F65K 15638.00 480 25% FCBN 710 48.6 1234 27.4 696 13.6 345 40 22.5 MPZB22T2F65K 18652.00 480 25% FCBN 725 48.6 1234 27.4 696 13.6 345 70 30 MPZB30T2F65K 22204.00 480 25% FCBN 755 48.6 1234 27.4 696 13.6 345 90 b Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints. NOTE: FCBN = full capacity below normal
60 80 100
24 or 8
Output Single-Phase Panel Rated 120/240 5 MPZ5S40FSS 11030.00 480 25% FCBN 7.5 MPZ7S40FSS 12428.00 480 25% FCBN 10 MPZ10S40FSS 12920.00 480 25% FCBN 15 MPZ15S40FSS 14758.00 480 25% FCBN 25 MPZ25S40FSS 17266.00 480 25% FCBN Output Three-Phase Panel Rated 208Y/120 15 22.5 30 c
MPZ15T2FSS 20108.00 480 25% FCBN 710 44.6 1133 27.4 696 13.6 345 40 MPZ22T2FSS 23122.00 480 25% FCBN 725 44.6 1133 27.4 696 13.6 345 70 MPZ30T2FSS 24376.00 480 25% FCBN 755 44.6 1133 27.4 696 13.6 345 90 Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints.
60 80 100
24 or 8
Table 14.35: With QOB Bolt-On Feeder Circuit Breakers Interrupting Rating: 18 kAIC
kVA Catalog No. $ Price Input Voltage Full Capacity Taps Dimensions d Weight (lbs) In. 175 200 215 390 390 41.0 41.0 41.0 51.0 51.0 H mm 1041 1041 1041 1295 1295 In. 12.0 12.0 12.0 17.4 17.4 W mm 305 305 305 442 442 In. 11.9 11.9 11.9 13.5 13.5 D Primary Secondary Main Circuit Main Circuit Breaker Breaker mm Rating (A) Rating (A) 41.0 41.0 41.0 51.0 51.0 15 20 30 60 100 30 40 60 80 125 Feeder Breakers Max. No. 1- or 2-Pole Max. A 20 30 40 60 100 Max. A 40 60 80
Output Single-Phase Panel Rated 120/240 5 MPZB5S40FSS 13780.00 480 25% FCBN 7.5 MPZB7S40FSS 15542.00 480 25% FCBN 10 MPZB10S40FSS 16159.00 480 25% FCBN 15 MPZB15S40FSS 18442.00 480 25% FCBN 25 MPZB25S40FSS 21583.00 480 25% FCBN Output Three-Phase Panel Rated 208Y/120 15 22.5 30 d
MPZB15T2FSS 25135.00 480 25% FCBN 710 48.6 1234 27.4 696 13.6 48.6 40 MPZB22T2FSS 28896.00 480 25% FCBN 725 48.6 1234 27.4 696 13.6 48.6 70 MPZB30T2FSS 30476.00 480 25% FCBN 755 48.6 1234 27.4 696 13.6 48.6 90 Dimensions: DO NOT use for construction. Contact your local Schneider Electric sales office for certified prints.
60 80 100
24 or 8
NOTE: FCBN = full capacity below normal 2009 Schneider Electric All Rights Reserved Discount Schedule
PE2
14-13
14
TRANSFORMERS
Industrial Control
Class 9070 / Refer to Catalog 9070CT9901
www.schneider-electric.us
Type T transformers are designed with low impedance windings for excellent voltage regulation and can accommodate the high inrush current associated with contactors, starters, solenoids, and relays. As the most popular and complete line of control transformers with unmatched design innovations for top performance, Type Ts are manufactured using the most advanced insulating materials and are the best choice if size and cost are of concern. It is available in the MultiTap version, designed to respond to the increased need for voltage and stock flexibility. It combines multiple primary voltages with one or more secondary voltages, all in a single transformer. Table 14.36:
VA UL/ CSA/ NOM VA CE
CE
Catalog No.
$ Price
In.
mm
In.
mm
In.
mm
Type T Transformers
Catalog No. $ Price In. mm In. mm In. mm Weight (lbs) H W D
Primary 240 V x 480 V Secondary 120 V; Primary 230 V x 460 V Secondary 115 V; or Primary 220 V x 440 V Secondary 110 V 25 25 9070T25D1 111.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 50 50 9070T50D1 116.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D1 138.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D1 155.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D1 165.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D1 204.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D1 239.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D1 264.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D1 281.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D1 350.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D1 483.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D1 585.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D1 837.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D1 1017.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D1 1412.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D1 2373.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0 Primary 208 V Secondary 120 V 50 50 9070T50D3 135.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D3 162.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D3 182.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D3 230.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D3 293.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D3 363.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D3 372.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D3 432.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D3 471.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D3 665.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D3 837.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D3 1170.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D3 1358.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D3 1914.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D3 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0 Primary 600 V Secondary 120/240 V; Primary 575 V Secondary 115/230 V 50 50 9070T50D37 135.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D37 162.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D37 182.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D37 230.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D37 293.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D37 363.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D37 372.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D37 432.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D37 471.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D37 665.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D37 837.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D37 1170.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D37 1358.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D37 1914.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D37 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0 Primary 120 V Secondary 120 V; Primary 115 V Secondary 115 V; or Primary 110 V Secondary 110 V 2.5 50 50 9070T50D24 468.00 2.58 65.5 3.00 76.2 3.09 78.5 75 75 9070T75D24 486.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D24 489.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D24 522.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D24 713.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D24 716.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D24 722.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D24 725.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D24 747.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D24 840.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D24 891.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D24 1076.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D24 1394.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D24 2195.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D24 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0
Primary 277 V Secondary 120 V 50 50 9070T50D4 135.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D4 162.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D4 182.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D4 230.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D4 293.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D4 363.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D4 372.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D4 432.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D4 471.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D4 665.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D4 837.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D4 1170.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D4 1358.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D4 1914.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D4 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0 Primary 240 V x 480 V Secondary 120/240 V; Primary 230 V x 460 V Secondary 115/230 V; or Primary 220 V x 440 V Secondary 110/220 V 50 50 9070T50D31 188.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D31 197.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D31 207.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D31 273.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D31 353.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D31 372.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D31 435.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D31 455.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D31 509.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D31 710.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D31 837.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D31 1224.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D31 1358.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D31 2229.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D31 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0 Primary 120 V x 240 V Secondary 120/240 V; Primary 115 V x 230 V Secondary 115/230 V; or Primary 110 V x 220 V Secondary 110/220 V 50 50 9070T50D55 468.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D55 486.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D55 489.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D55 522.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D55 713.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D55 716.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D55 722.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D55 725.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D55 747.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D55 840.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D55 891.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D55 1284.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D55 1394.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D55 2382.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D55 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0 Primary 240 V X 480 V Secondary 24/120 V (24 V limited to 20% Capacity) 50 50 9070T50D15 135.00 2.58 65.5 3.00 76.2 3.09 78.5 2.5 75 75 9070T75D15 162.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 100 100 9070T100D15 207.00 2.89 73.4 3.38 85.8 3.34 84.8 3.8 150 150 9070T150D15 230.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 200 200 9070T200D15 293.00 3.20 81.3 3.75 95.3 3.59 91.2 5.5 250 160 9070T250D15 372.00 3.25 82.6 3.75 95.3 5.25 133.4 7.1 300 200 9070T300D15 435.00 3.80 96.5 4.50 114.3 4.70 119.4 8.5 350 250 9070T350D15 455.00 3.80 96.5 4.50 114.3 5.09 129.3 10.5 500 300 9070T500D15 509.00 3.80 6.5 4.50 114.3 5.46 138.7 11.9 750 500 9070T750D15 710.00 4.43 112.5 5.25 133.4 5.66 143.8 11.0 1000 630 9070T1000D15 837.00 4.43 112.5 5.25 133.4 6.04 153.4 20.6 1500 1000 9070T1500D15 1224.00 6.16 156.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070T2000D15 1358.00 6.16 156.5 7.06 179.3 7.04 178.8 47.0 3000 2000 9070T3000D15 2229.00 8.46 214.9 9.00 228.6 6.86 174.2 60.0 5000 3000 9070T5000D15 3015.00 8.46 214.9 9.00 228.6 8.73 221.7 89.0
14-14
CP8
Discount Schedule
Weight (lbs)
VA
VA
14
TRANSFORMERS
Industrial Control
Class 9070 / Refer to Catalog 9070CT9901
www.schneider-electric.us
VA VA Catalog $ Price UL/CSA/ No. CE NOM Primary 240 V x 480 V Secondary 24 V 50 50 9070T50D2 135.00 75 75 9070T75D2 162.00 100 100 9070T100D2 182.00 150 150 9070T150D2 230.00 200 200 9070T200D2 293.00 250 160 9070T250D2 363.00 300 200 9070T300D2 372.00 350 250 9070T350D2 432.00 500 300 9070T500D2 471.00 750 500 9070T750D2 471.00 1000 630 9070T1000D2 665.00 Primary 120 V Secondary 12/24 V 50 50 9070T50D13 135.00 75 75 9070T75D13 162.00 100 100 9070T100D13 182.00 150 150 9070T150D13 230.00 200 200 9070T200D13 293.00 250 160 9070T250D13 363.00 300 200 9070T300D13 372.00 350 250 9070T350D13 432.00 500 300 9070T500D13 471.00 750 500 9070T750D13 665.00 1000 630 9070T1000D13 837.00 Primary 120 V x 240 V Secondary 24 V 50 50 9070T50D23 135.00 75 75 9070T75D23 162.00 100 100 9070T100D23 182.00 150 150 9070T150D23 230.00 200 200 9070T200D23 293.00 250 160 9070T250D23 363.00 300 200 9070T300D23 372.00 350 250 9070T350D23 432.00 500 300 9070T500D23 471.00 750 500 9070T750D23 665.00 1000 630 9070T1000D23 837.00 Primary 208 V Secondary 24 V 50 50 9070T50D14 135.00 75 75 9070T75D14 162.00 100 100 9070T100D14 182.00 150 150 9070T150D14 230.00 200 200 9070T200D14 293.00 250 160 9070T250D14 363.00 300 200 9070T300D14 372.00 350 250 9070T350D14 432.00 500 300 9070T500D14 471.00 750 500 9070T750D14 665.00 1000 630 9070T1000D14 837.00 Primary 277 V Secondary 24 V 50 50 9070T50D25 468.00 75 75 9070T75D25 486.00 100 100 9070T100D25 489.00 150 150 9070T150D25 522.00 200 200 9070T200D25 713.00 250 160 9070T250D25 716.00 300 200 9070T300D25 722.00 350 250 9070T350D25 725.00 500 300 9070T500D25 747.00 750 500 9070T750D25 840.00 1000 630 9070T1000D25 891.00 Primary 600 V Secondary 12/24 V 50 50 9070T50D36 468.00 75 75 9070T75D36 486.00 100 100 9070T100D36 489.00 150 150 9070T150D36 522.00 200 200 9070T200D36 713.00 250 160 9070T250D36 716.00 300 200 9070T300D36 722.00 350 250 9070T350D36 725.00 500 300 9070T500D36 747.00 750 500 9070T750D36 840.00 1000 630 9070T1000D36 891.00
Weight (lbs)
In. 2.58 2.89 2.89 3.20 3.20 3.25 3.80 3.80 3.80 4.43 4.43 2.58 2.89 2.89 3.20 3.20 3.25 3.80 3.80 3.80 4.43 4.43 2.58 2.89 2.89 3.20 3.20 3.25 3.80 3.80 3.80 4.43 4.43 2.58 2.89 2.89 3.20 3.20 3.25 3.80 3.80 3.80 4.43 4.43 2.58 2.89 2.89 3.20 3.20 3.25 3.80 3.80 3.80 4.43 4.43 2.58 2.89 2.89 3.20 3.20 3.25 3.80 3.80 3.80 4.43 4.43
mm 65.5 73.4 73.4 81.3 81.3 82.6 96.5 96.5 6.5 112.5 112.5 65.5 73.4 73.4 81.3 81.3 82.6 96.5 96.5 6.5 112.5 112.5 65.5 73.4 73.4 81.3 81.3 82.6 96.5 96.5 6.5 112.5 112.5 65.5 73.4 73.4 81.3 81.3 82.6 96.5 96.5 6.5 112.5 112.5 65.5 73.4 73.4 81.3 81.3 82.6 96.5 96.5 6.5 112.5 112.5 65.5 73.4 73.4 81.3 81.3 82.6 96.5 96.5 6.5 112.5 112.5
In. 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25
mm 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4
In. 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04
mm 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4
In. 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 7.06 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 7.06 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 7.06 3.00 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25
mm 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 179.3 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 179.3 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 179.3 76.2 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4
In. 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 5.81 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 5.81 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 5.81 3.09 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04
mm 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 147.6 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 147.6 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 147.6 78.5 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4
2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6
Weight (lbs) 4.0 5.5 5.5 5.5 8.5 10.5 10.5 11.9 11.0 20.6 34.0 4.0 5.5 5.5 5.5 8.5 10.5 10.5 11.9 11.0 20.6 34.0 4.0 5.5 5.5 5.5 8.5 10.5 10.5 11.9 11.0 20.6 34.0 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 4.0 7.2 7.1 8.5 10.5 10.5 11.9 11.0 11.0 20.6 34.0 4.0 7.2 7.2 7.1 8.5 10.5 11.9 11.9 11.0 20.6 34.0
VA VA H Catalog $ Price UL/CSA/ No. CE In. mm NOM Primary 208/277/380 V Secondary 95/115 V 50 50 9070T50D18 188.00 2.89 73.4 75 75 9070T75D18 197.00 2.89 73.4 100 100 9070T100D18 207.00 3.20 81.3 150 150 9070T150D18 273.00 3.20 81.3 200 200 9070T200D18 353.00 3.25 82.6 250 160 9070T250D18 372.00 3.80 96.5 300 200 9070T300D18 435.00 3.80 96.5 350 250 9070T350D18 455.00 3.80 6.5 500 300 9070T500D18 509.00 4.43 112.5 750 500 9070T750D18 710.00 4.43 112.5 1000 630 9070T1000D18 837.00 6.16 156.5 Primary 208/230/460 V Secondary 115 V 50 50 9070T50D20 188.00 2.89 73.4 75 75 9070T75D20 197.00 2.89 73.4 100 100 9070T100D20 207.00 3.20 81.3 150 150 9070T150D20 273.00 3.20 81.3 200 200 9070T200D20 353.00 3.25 82.6 250 160 9070T250D20 372.00 3.80 96.5 300 200 9070T300D20 435.00 3.80 96.5 350 250 9070T350D20 455.00 3.80 6.5 500 300 9070T500D20 509.00 4.43 112.5 750 500 9070T750D20 710.00 4.43 112.5 1000 630 9070T1000D20 837.00 6.16 156.5 Primary 240/480/600 V Secondary 100/120 V 50 50 9070T50D32 188.00 2.89 73.4 75 75 9070T75D32 197.00 2.89 73.4 100 100 9070T100D32 207.00 3.20 81.3 150 150 9070T150D32 273.00 3.20 81.3 200 200 9070T200D32 353.00 3.25 82.6 250 160 9070T250D32 372.00 3.80 96.5 300 200 9070T300D32 435.00 3.80 96.5 350 250 9070T350D32 455.00 3.80 6.5 500 300 9070T500D32 509.00 4.43 112.5 750 500 9070T750D32 710.00 4.43 112.5 1000 630 9070T1000D32 837.00 6.16 156.5 Primary 380/400/415 V Secondary 115/230 V 50 50 9070T50D33 188.00 2.58 65.5 75 75 9070T75D33 197.00 2.89 73.4 100 100 9070T100D33 207.00 2.89 73.4 150 150 9070T150D33 273.00 3.20 81.3 200 200 9070T200D33 353.00 3.20 81.3 250 160 9070T250D33 372.00 3.25 82.6 300 200 9070T300D33 435.00 3.80 96.5 350 250 9070T350D33 455.00 3.80 96.5 500 300 9070T500D33 509.00 3.80 6.5 750 500 9070T750D33 710.00 4.43 112.5 1000 630 9070T1000D33 837.00 4.43 112.5 Primary 240/416/480/600 V Secondary 99/120/130 V; Primary 230/400/460/575 V Secondary 95/115/125 V Primary 220/380/440/550 V Secondary 90/110/120 V; Primary 208/360/416/520 V Secondary 85/104/115 V 50 50 9070T50D50 315.00 2.89 73.4 75 75 9070T75D50 341.00 2.89 73.4 100 100 9070T100D50 350.00 3.20 81.3 150 150 9070T150D50 366.00 3.20 81.3 200 200 9070T200D50 417.00 3.25 82.6 250 160 9070T250D50 455.00 3.80 96.5 300 200 9070T300D50 497.00 3.80 96.5 350 250 9070T350D50 512.00 3.80 6.5 500 300 9070T500D50 656.00 4.43 112.5 750 500 9070T750D50 761.00 4.43 112.5 1000 630 9070T1000D50 996.00 6.16 156.5 Primary 208/240/277/380/480 V Secondary 24 V 50 50 9070T50D19 188.00 2.89 73.4 75 75 9070T75D19 197.00 2.89 73.4 100 100 9070T100D19 207.00 3.20 81.3 150 150 9070T150D19 273.00 3.20 81.3 200 200 9070T200D19 353.00 3.25 82.6 250 160 9070T250D19 372.00 3.80 96.5 300 200 9070T300D19 435.00 3.80 96.5 350 250 9070T350D19 455.00 3.80 6.5 500 300 9070T500D19 509.00 4.43 112.5 750 500 9070T750D19 710.00 4.43 112.5 1000 630 9070T1000D19 837.00 4.43 112.5
3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 7.06 3.38 3.38 3.75 3.75 3.75 4.50 4.50 4.50 5.25 5.25 5.25
85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 179.3 85.8 85.8 95.3 95.3 95.3 114.3 114.3 114.3 133.4 133.4 133.4
3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 5.81 3.34 3.34 3.59 3.59 5.25 4.70 5.09 5.46 5.66 6.04 6.04
84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 147.6 84.8 84.8 91.2 91.2 133.4 119.4 129.3 138.7 143.8 153.4 153.4
CP8
Discount Schedule
14-15
14
TRANSFORMERS
Industrial Control
Class 9070 / Refer to Catalog 9070CT9901
www.schneider-electric.us
Schneider Electric offers Type TF transformers with factory-installed overcurrent protection fuse blocks. The Type TF transformer consists of two primary fuse blocks and one secondary fuse block, a configuration that meets the majority of overcurrent needs by panel builders and machinery OEMs. Since the fuse blocks are pre-wired and mounted on top of the transformer, the Type TF transformer has the same footprint as the Type T transformer. This design frees up space normally used for separate fuse blocks. Schneider Electric also offers an extensive fuse block offering for custom applications. Table 14.37:
VA VA
Type TF Transformers
Weight (lbs)
H W D Catalog $ Price UL/CSA/ No. CE In. mm In. mm In. mm NOM Primary 240 V x 480 V Secondary 120 V; Primary 230 V x 460 V Secondary 115 V; or Primary 220 V x 440 V Secondary 110 V 25 25 9070TF25D1 110.00 4.00 101.6 3.00 76.2 3.09 78.5 2.5 50 50 9070TF50D1 165.00 4.00 101.6 3.00 76.2 3.84 78.5 2.5 75 75 9070TF75D1 185.00 4.25 107.9 3.38 85.8 3.34 84.8 3.8 100 100 9070TF100D1 201.00 4.25 107.9 3.38 85.8 3.34 84.8 3.8 150 150 9070TF150D1 213.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 200 200 9070TF200D1 255.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 250 160 9070TF250D1 287.00 4.55 115.6 3.75 95.3 5.25 133.4 7.1 300 200 9070TF300D1 312.00 5.10 129.6 4.50 114.3 4.70 119.4 8.5 350 250 9070TF350D1 330.00 5.10 129.6 4.50 114.3 5.09 129.3 10.5 500 300 9070TF500D1 395.00 5.10 129.6 4.50 114.3 5.46 138.7 11.9 750 500 9070TF750D1 531.00 5.73 145.6 5.25 133.4 5.66 143.8 11.0 1000 630 9070TF1000D1 639.00 5.73 145.6 5.25 133.4 6.04 153.4 20.6 1500 1000 9070TF1500D1 884.00 7.46 189.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070TF2000D1 1065.00 7.46 189.5 7.06 179.3 7.04 178.8 47.0 Primary 208 V Secondary 120 V 50 50 9070TF50D3 185.00 4.00 101.6 3.00 76.2 3.84 78.5 2.5 75 75 9070TF75D3 230.00 4.25 107.9 3.38 85.8 3.34 84.8 3.8 100 100 9070TF100D3 276.00 4.25 107.9 3.38 85.8 3.34 84.8 3.8 150 150 9070TF150D3 287.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 200 200 9070TF200D3 293.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 250 160 9070TF250D3 381.00 4.55 115.6 3.75 95.3 5.25 133.4 7.1 300 200 9070TF300D3 426.00 5.10 129.6 4.50 114.3 4.70 119.4 8.5 350 250 9070TF350D3 522.00 5.10 129.6 4.50 114.3 5.09 129.3 10.5 500 300 9070TF500D3 696.00 5.10 129.6 4.50 114.3 5.46 138.7 11.9 750 500 9070TF750D3 807.00 5.73 145.6 5.25 133.4 5.66 143.8 11.0 1000 630 9070TF1000D3 906.00 5.73 145.6 5.25 133.4 6.04 153.4 20.6 1500 1000 9070TF1500D3 1209.00 7.46 189.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070TF2000D3 1352.00 7.46 189.5 7.06 179.3 7.04 178.8 47.0 Primary 240 V x 480 V Secondary 120/240 V; Primary 230 V x 460 V Secondary 115/230 V; or Primary 220 V x 440 V Secondary 110/220 V 50 50 9070TF50D31 548.00 4.00 101.6 3.00 76.2 3.84 78.5 2.5 75 75 9070TF75D31 560.00 4.25 107.9 3.38 85.8 3.34 84.8 3.8 100 100 9070TF100D31 563.00 4.25 107.9 3.38 85.8 3.34 84.8 3.8 150 150 9070TF150D31 581.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 200 200 9070TF200D31 779.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 250 160 9070TF250D31 792.00 4.55 115.6 3.75 95.3 5.25 133.4 7.1 300 200 9070TF300D31 795.00 5.10 129.6 4.50 114.3 4.70 119.4 8.5 350 250 9070TF350D31 804.00 5.10 129.6 4.50 114.3 5.09 129.3 10.5 500 300 9070TF500D31 821.00 5.10 129.6 4.50 114.3 5.46 138.7 11.9 750 500 9070TF750D31 875.00 5.73 145.6 5.25 133.4 5.66 143.8 11.0 1000 630 9070TF1000D31 951.00 5.73 145.6 5.25 133.4 6.04 153.4 20.6 1500 1000 9070TF1500D31 1320.00 7.46 189.5 7.06 179.3 5.81 147.6 34.0 2000 1500 9070TF2000D31 1409.00 7.46 189.5 7.06 179.3 7.04 178.8 47.0 Primary 208/277/380 V Secondary 95/115 V 50 50 9070TF50D18 548.00 4.00 101.6 3.00 76.2 3.84 78.5 4.0 75 75 9070TF75D18 554.00 4.25 107.9 3.38 85.8 3.34 84.8 5.5 100 100 9070TF100D18 588.00 4.25 107.9 3.38 85.8 3.34 84.8 5.5 150 150 9070TF150D18 624.00 4.55 115.6 3.75 95.3 3.59 91.2 5.5 200 200 9070TF200D18 833.00 4.55 115.6 3.75 95.3 3.59 91.2 8.5 846.00 4.55 115.6 3.75 95.3 5.25 133.4 10.5 250 160 9070TF250D18 300 200 9070TF300D18 855.00 5.10 129.6 4.50 114.3 4.70 119.4 10.5 350 250 9070TF350D18 957.00 5.10 129.6 4.50 114.3 5.09 129.3 11.9 500 300 9070TF500D18 1380.00 5.10 129.6 4.50 114.3 5.46 138.7 11.0 750 500 9070TF750D18 1580.00 5.73 145.6 5.25 133.4 5.66 143.8 20.6 1000 630 9070TF1000D18 1988.00 5.73 145.6 5.25 133.4 6.04 153.4 34.0
14-16
CP8
Discount Schedule
Weight (lbs) 4.0 5.5 5.5 5.5 8.5 10.5 10.5 11.9 11.0 20.6 34.0 4.0 5.5 5.5 5.5 8.5 10.5 10.5 11.9 11.0 20.6 34 2.5 3.8 3.8 5.5 5.5 7.1 8.5 10.5 11.9 11.0 20.6 4.0 7.2 7.1 8.5 10.5 10.5 11.9 11.0 11.0 20.6 34.0
Type TF Transformers
VA VA H W D Catalog $ Price UL/CSA/ No. CE In. mm In. mm In. mm NOM Primary 208/230/460 V Secondary 115 V 50 50 9070TF50D20 270.00 4.25 107.9 3.38 87.1 3.34 106.4 75 75 9070TF75D20 293.00 4.55 115.6 3.75 95.3 3.59 91.2 100 100 9070TF100D20 360.00 4.55 115.6 3.75 95.3 3.59 91.2 150 150 9070TF150D20 443.00 4.55 115.6 3.75 95.3 3.59 91.2 200 200 9070TF200D20 497.00 5.10 129.6 4.50 114.3 4.70 119.4 250 160 9070TF250D20 548.00 5.10 129.6 4.50 114.3 5.09 129.3 300 200 9070TF300D20 563.00 5.10 129.6 4.50 114.3 5.09 129.3 350 250 9070TF350D20 585.00 5.10 129.6 4.50 114.3 5.46 138.7 500 300 9070TF500D20 608.00 5.73 145.6 5.25 133.4 5.66 143.8 750 500 9070TF750D20 951.00 5.73 145.6 5.25 133.4 6.04 153.4 1000 630 9070TF1000D20 1320.00 7.46 189.5 7.06 179.3 5.81 147.6 Primary 230/460/575 V Secondary 95/115 V 50 50 9070TF50D32 600.00 4.25 107.9 3.38 87.1 3.34 106.4 75 75 9070TF75D32 617.00 4.55 115.6 3.75 95.3 3.59 91.2 100 100 9070TF100D32 620.00 4.55 115.6 3.75 95.3 3.59 91.2 150 150 9070TF150D32 624.00 4.55 115.6 3.75 95.3 3.59 91.2 200 200 9070TF200D32 833.00 5.10 129.6 4.50 114.3 4.70 119.4 250 160 9070TF250D32 846.00 5.10 129.6 4.50 114.3 5.09 129.3 300 200 9070TF300D32 866.00 5.10 129.6 4.50 114.3 5.09 129.3 350 250 9070TF350D32 866.00 5.10 129.6 4.50 114.3 5.46 138.7 500 300 9070TF500D32 869.00 5.73 145.6 5.25 133.4 5.66 143.8 750 500 9070TF750D32 1380.00 5.73 145.6 5.25 133.4 6.04 153.4 1000 630 9070TF1000D32 1380.00 7.46 189.5 7.06 179.3 5.81 147.6 Primary 600 V Secondary 120/240 V; Primary 575 V Secondary 115/230 V 50 50 9070TF50D37 195.00 4.00 101.6 3.00 76.2 3.09 78.5 75 75 9070TF75D37 384.00 4.25 107.9 3.38 85.8 3.34 84.8 100 100 9070TF100D37 394.00 4.25 107.9 3.38 85.8 3.34 84.8 150 150 9070TF150D37 452.00 4.55 115.6 3.75 95.3 3.59 91.2 200 200 9070TF200D37 498.00 4.55 115.6 3.75 95.3 3.59 91.2 250 160 9070TF250D37 564.00 4.55 115.6 3.75 95.3 5.25 133.4 300 200 9070TF300D37 570.00 5.10 129.6 4.50 114.3 4.70 119.4 350 250 9070TF350D37 570.00 5.10 129.6 4.50 114.3 5.09 129.3 500 300 9070TF500D37 638.00 5.10 129.6 4.50 114.3 5.46 138.7 750 500 9070TF750D37 668.00 5.73 145.6 5.25 133.4 5.66 143.8 1000 630 9070TF1000D37 920.00 5.73 145.6 5.25 133.4 6.04 153.4 Primary 240/416/480/600 V Secondary 99/120/130 V; Primary 230/400/460/575 V Secondary 95/115/125 V Primary 220/380/440/550 V Secondary 90/110/120 V; Primary 208/360/416/520 V Secondary 85/104/115 V 50 50 9070TF50D50 274.00 4.25 107.9 3.43 87.1 4.19 106.4 75 75 9070TF75D50 290.00 4.55 115.6 3.75 95.3 4.88 124.0 100 100 9070TF100D50 297.00 4.55 115.6 3.75 95.3 5.25 133.4 150 150 9070TF150D50 312.00 5.10 129.6 4.50 114.3 4.70 119.4 200 200 9070TF200D50 341.00 5.10 129.6 4.50 114.3 5.09 129.3 250 160 9070TF250D50 394.00 5.10 129.6 4.50 114.3 5.09 129.3 300 200 9070TF300D50 405.00 5.10 129.6 4.50 114.3 5.46 138.7 350 250 9070TF350D50 429.00 5.73 145.6 5.25 133.4 5.66 143.8 500 300 9070TF500D50 502.00 5.73 145.6 5.25 133.4 5.66 143.8 750 500 9070TF750D50 572.00 7.46 189.5 5.25 133.4 6.04 153.4 1000 630 9070TF1000D50 727.00 5.10 129.6 7.06 179.3 5.81 147.6
14
TRANSFORMERS
Industrial Control
Class 9070 / Refer to Catalog 9070CT9901
www.schneider-electric.us
Accessories
The Type T control transformers offer multiple field installable accessories: Table 14.38:
Type I
Table 14.44:
Type I
FSC1 T25T200 T25T150 2 covers per kit 21.00 10 210.00 FSC2 T250T5000 T250T5000 2 covers per kit 30.00 10 300.00 FSC23 T25T5000 2 covers per kit 30.00 10 300.00 a Kits must be ordered separately. Also supplied in bulk packages of 100 individual covers. Add B to Type number (available only on FSC1B and FSC2B).
Table 14.39:
Class 9991 Type UE7 LG1 SDG4
NOTE: User must drill mounting holes. See pages 16-106 and 16-107 for dimensions.
Table 14.40:
Catalog No. 3003302753
Jumper Kits
$ Price Each I II T25T150 III, IV Description Order Qty. Type Accessory Key Order $ Price
5.00
50
250.00
NOTE: Jumpers are supplied with voltage codes that require them. If additional kits are required, order per above chart.
Selection Guide
1. Determine inrush and sealed VA of each coil in the control circuit and VA of all other components. 2. Total all sealed VA of all operating coils and other loads VA (determines minimal VA size required for the circuit). 3. Total the inrush VA of all coils that are starting at the same time and all loads and coils that are running (using the regulation chart to give possible units to be used). 4. Take VA size from step two, go to standard VA size in chart. Make sure inrush VA from chart is greater than total VA from step three. (If not, go to next larger VA size and repeat.) If your supply voltage is stable and fluctuates less than 5%, Schneider Electric recommends you use the 90% secondary voltage column. If your supply voltage is not stable and fluctuates more than 10% we recommend you use the 95% secondary voltage column. We recommend that you never use the 85% secondary voltage column since magnetic devices lose life expectancy if they are continuously started at 85% of rated voltage. Table 14.45:
VA
Table 14.41:
Catalog No.
FB3A
25200
25150
87.00
87.00
FB3B
2502000
2002000 252000
87.00
87.00
Inrush VA @ 20% power factor 95% Secondary Voltage 193 271 339 666 588 1416 1634 1894 3197 3770 6587 19324 31384 26539 53111
Table 14.43:
Type I
Primary Fusing
$ Price Each II III, IV Description Order $ Price Order Qty.
Two pole fuse block for primary fusing, accommodates 1-1/2 x 13/32 inch midget fuse (2 rejection) Two pole fuse block for primary fusing, FB2B 2502000 2002000 252000 accommodates 1-1/2 x 13/32 inch midget fuse (2 rejection) FB2A 25200 25150
75.00
75.00
75.00
75.00
50 75 100 150 200 250 300 350 500 750 1000 1500 2000 3000 5000
CP8
Discount Schedule
14-17
14
TRANSFORMERS
Two jumpers per bag Minimum order 3003302754 T250T5000 T200T3000 T25T3000 of 50 kits T25T200
8.00
50
400.00
Secondary fuse block SF25A 25200 25150 accommodates 21.00 10 210.00 1-1/4 x 1/4 inch fuse Secondary fuse block SF25B 2502000 2002000 252000 accommodates 21.00 10 210.00 1-1/4 x 1/4 inch fuse Secondary fuse clip accommodates SF41A b 25200 25150 18.00 10 180.00 1-1/2 x 13/32 inch midget fuse Secondary fuse clip accommodates SF41B b 2502000 2002000 252000 18.00 10 180.00 1-1/2 x 13/32 inch midget fuse One pole fuse block for secondary fusing, accommodates FB1A 25200 25150 53.00 1 53.00 1-1/2 x 13/32 inch midget fuse (1 non-rejection) One pole fuse block for secondary fusing, accommodates 53.00 1 53.00 FB1B 2502000 2002000 252000 1-1/2 x 13/32 inch midget fuse (1 non-rejection) b SF41 can be installed on the following voltage codes: D1, D5, D24, D3, D4, D51, D2, D23, D14, D25, D20, D95, D19, D22, D36. c I = voltage codes D1, D2, D3, D4, D5, D12, D13, D14, D15, D23, D24, D25, D31, D32, D33, D36, D5 II = voltage codes D18, D20 III, IV= voltage codes D19, D50
Transformer Disconnects
Transformer Disconnects available in NEMA 1 Standard, NEMA 12 Standard, and NEMA 1 Mini
Table 14.46:
VA
14
TRANSFORMERS
In. mm NEMA 1 Enclosure, Primary 240 x 480 Secondary 120 (Compact Design) 100 9070MN100G0D1 1338.00 G0 7.00 178 250 9070MN250G0D1 1488.00 G0 7.00 178 500 9070MN500G0D1 1640.00 G0 7.00 178 750 9070SK750G3D1 1721.00 G3 13.40 340 1000 9070SK1000G3D1 2259.00 G3 13.40 340 1500 9070SK1500G3D1 3351.00 G3 13.40 340 2000 9070SK2000G3D1 2838.00 G3 13.40 340 3000 9070SK3000G3D1 3797.00 G3 13.40 340 NEMA 1 Enclosure, Primary 240 x 480 Secondary 120 250 9070SK250G1D1 1353.00 G1 9.40 239 500 9070SK500G1D1 1488.00 G1 9.40 239 750 9070SK750G1D1 1674.00 G1 9.40 239 1000 9070SK1000G1D1 2199.00 G1 9.40 239 1500 9070SK1500G2D1 3255.00 G2 13.40 340 2000 9070SK2000G2D1 3699.00 G2 13.40 340 3000 9070SK3000G2D1 4955.00 G2 13.40 340 NEMA 1 Enclosure, Primary 480 Secondary 120 5000 9070SK5000G4D9 7748.00 G4 16.90 429 NEMA 12 Enclosure, Primary 240 x 480 Secondary 120 250 9070SK250A2D1 3281.00 A2 16.50 419 500 9070SK500A2D1 3417.00 A2 16.50 419 750 9070SK750A2D1 3621.00 A2 16.50 419 1000 9070SK1000A2D1 3723.00 A2 16.50 419 1500 9070SK1500A2D1 4095.00 A2 16.50 419 2000 9070SK2000A2D1 4364.00 A2 16.50 419 3000 9070SK3000A2D1 5448.00 A2 16.50 419 NEMA 12 Enclosure, Primary 240 x 480 Secondary 120, Flange Switch 250 9070SK250A3D1 3281.00 A3 15.50 394 500 9070SK500A3D1 3417.00 A3 15.50 394 750 9070SK750A3D1 3621.00 A3 15.50 394 1000 9070SK1000A3D1 3723.00 A3 15.50 394 1500 9070SK1500A3D1 4095.00 A3 15.50 394 2000 9070SK2000A3D1 4364.00 A3 15.50 394
14-18
CP8
Discount Schedule
Transformer Disconnects
www.schneider-electric.us
Table 14.47:
VA
H W D Weight (lbs) In. mm In. mm In. mm NEMA 1 Enclosure, Primary 240 x 480 Secondary 120, Duplex Receptacle, Door-Mounted (Compact Design) 100 9070MN100G0D1G13 1659.00 G0 7.00 178 11.30 287 7.81 198 16 250 9070MN250G0D1G13 1808.00 G0 7.00 178 11.30 287 7.81 198 21 500 9070MN500G0D1G13 1961.00 G0 7.00 178 11.30 287 7.81 198 24 750 9070SK750G3D1G13 2007.00 G3 13.40 340 14.80 376 10.21 259 47 1000 9070SK1000G3D1G13 2546.00 G3 13.40 340 14.80 376 10.21 259 51 1500 9070SK1500G3D1G13 3638.00 G3 13.40 340 14.80 376 10.21 259 65 2000 9070SK2000G3D1G13 4088.00 G3 13.40 340 14.80 376 10.21 259 71 3000 9070SK3000G3D1G13 5562.00 G3 13.40 340 14.80 376 10.21 259 85 NEMA 1 Enclosure, Primary 240 x 480 Secondary 120, Duplex Receptacle, Door-Mounted 250 9070SK250G1D1G13 1674.00 G1 9.40 239 11.80 300 8.96 228 26 500 9070SK500G1D1G13 1808.00 G1 9.40 239 11.80 300 8.96 228 28 750 9070SK750G1D1G13 1994.00 G1 9.40 239 11.80 300 8.96 228 33 1000 9070SK1000G1D1G13 2520.00 G1 9.40 239 11.80 300 8.96 228 37 1500 9070SK1500G2D1G13 3576.00 G2 13.40 340 14.80 376 12.21 310 67 2000 9070SK2000G2D1G13 4020.00 G2 13.40 340 14.80 376 12.21 310 73 3000 9070SK3000G2D1G13 5274.00 G2 13.40 340 14.80 376 12.21 310 87 NEMA 1 Enclosure, Primary 480 Secondary 120, Duplex Receptacle, Door-Mounted 5000 9070SK5000G4D9 7748.00 G4 16.9 429 18.2 462 14.5 368 125 NEMA 12 Enclosure, Primary 240 x 480 Secondary 120, Duplex Receptacle, Door-Mounted 250 9070SK250A2D1G13 3216.00 A2 16.50 419 14.50 368 13.50 343 46 500 9070SK500A2D1G13 3738.00 A2 16.50 419 14.50 368 13.50 343 49 750 9070SK750A2D1G13 3941.00 A2 16.50 419 14.50 368 13.50 343 53 A2 16.50 419 14.50 368 13.50 343 58 1000 9070SK1000A2D1G13 4076.00 1500 9070SK1500A2D1G13 3942.00 A2 16.50 419 14.50 368 13.50 343 79 2000 9070SK2000A2D1G13 4685.00 A2 16.50 419 14.50 368 13.50 343 85 3000 9070SK3000A2D1G13 5769.00 A2 16.50 419 14.50 368 13.50 343 99 NEMA 12 Enclosure, Primary 240 x 480 Secondary 120, Flange Switch, Duplex Receptacle, Door-Mounted 100 9070MN100G0D1G13 1659.00 G0 7.00 178 11.30 287 7.81 198 16 250 9070SK250A3D1G13 3216.00 A3 15.50 394 17.00 432 10.00 254 48 500 9070SK500A3D1G13 3338.00 A3 15.50 394 17.00 432 10.00 254 53 750 9070SK750A3D1G13 3519.00 A3 15.50 394 17.00 432 10.00 254 57 1000 9070SK1000A3D1G13 4323.00 A3 15.50 394 17.00 432 10.00 254 61 1500 9070SK1500A3D1G13 3942.00 A3 15.50 394 17.00 432 10.00 254 75 2000 9070SK2000A3D1G13 4184.00 A3 15.50 394 17.00 432 10.00 254 86
Table 14.48:
Description 55 C rise transformer Electrostatically-shielded transformer Additional 1-1/2-inch x 13/32-inch secondary fuse block Primary fuse block5-inch x 13/16-inch Duplex receptacle, door-mounted Class A, GFI, duplex receptacle, door-mounted Two duplex receptacles, door-mounted ON red warning pilot light ON red warning pilot light, with strain relief
Contact your local Schneider Electric field sales office for other available features.
CP8
Discount Schedule
14-19
14
TRANSFORMERS
Voltage Transformers
Schneider Electric offers three models of voltage transformers, each suited for a particular application.
Model 450R is designed for applications requiring accurate voltage measurement within the 0.3% accuracy class. Model 450R is ideal for switchboard use with 1% instrumentation Model 460 is designed for voltage indication where accuracy is less critical or where burden requirements are low. Model 460R is ideally suited for use with transducers and panelboards and other monitoring applications. Model 470 is designed for extremely accurate voltage measurement where a very low burden is to be used. Examples of such applications include the input to PLC modules and other electronic devices with a high input impedance.
14
TRANSFORMERS
Current Transformers
Current transformers are low cost, compact units that offer good electrical performance in a general purpose transformer.
They are very easy to mount on the conductors. All current transformers feature permanent polarity marks molded into the case.
Type of CT available: General purpose Torroidal (single ratio) Rectangle window (single ratio) Split core Bushing (single ratio) (multi-ratio)
14-20
Table of Contents
Section 15
Medical Products
Line Isolation Monitor (LIM), Iso-Gard Series D Isolated Power Panels
Operating Room Panels ICU/CCU Panels Controlled Isolation Power Panels (For X-ray and Laser Receptacles) 15-1 15-2 15-2 15-2 15-2 15-3 15-3 15-3 15-4 15-4 15-4 15-5 15-6 15-6 15-6 15-6 15-6 15-6 15-6
Duplex Panels
Duplex Power Panels Power/Ground Modules
Accessories
Accessories Panels X-ray and Laser Receptacles Supervisory Modules Nurses Station Indicator-Alarm Annunciator Digital Clock/Timers Remote Alarm Indicators
The Square D brand Iso-Gard Series D microprocessor controlled line isolation monitor (LIM) is included as standard equipment in all Schneider Electric hospital isolation panels. This LIM is also available as a replacement unit for older LIMs, is a direct replacement for all previous Schneider Electric LIMs, and is electrically compatible with all hospital isolated power systems.
Standard Equipment
Table 15.1:
Specifications
85265 Vac, 50 or 60 Hz 2 or 5 mA (selectable) Single or three phase (selectable) 25 A or less
Operating Voltage Hazard Current Alarm Level Mode Monitor Hazard Current
NOTE: The National Electrical Code (NEC) requires audible and visual alarm indication where isolation power is used (NEC 517-160).
15-1
15
Automatic and manual self-test and self-calibration that reduces the frequency of required periodic testing Digital and analog display Unique audible alarm that will not be confused with other equipment UL component recognized and CSA classified Microprocessor controlled circuitry for highest accuracy and stability
MEDICAL PRODUCTS
All Square D brand Isolation Power Panels meet or exceed UL 1022 and 1047 and are cUL Listed. All products listed in this section are available through standard ordering procedures from authorized Schneider Electric distributors. For more information, contact your nearest Schneider Electric sales office or distributor. Call 1-888-Square D (778-2733) or visit www.schneider-electric.us.
Medical Products
Catalog Number Matrix (refer to Table 15.2 for the available options for each field)
Basic OR Panel ICU/CCU Panels Panel Type 5 Circuit Breaker Type 6 Total No. of Circuits 7 No. of 120 V Receptacles 8 Type of 120 V Receptacles 9 10 No. of Ground Jacks 11 Type of Control 8 Controlled Panels No. of Total No. of 'ON' Circuits Circuits 9 10 Output Amperes 11 Primary Voltage 3 Secondary Voltage 4
Panel Mounting 2
Table 15.2:
Options
ICU/CCU Panels Add these options to the basic OR panel for power / ground outputs. Number of 120 volt receptacles 8 8 maximum Type of 120 volt receptacles DR Duplex red DW Duplex white DI Duplex ivory 9-10 SR Single red SW Single white SI Single ivory HR Hospital-only (Hubbell 23000) TL L5-20 twist lock Number of ground jacks 11 6 Maximum Options for this section include a Music Center. The Music Center consists of an AM/FM radio with cassette, CD single player, or CD changer. Contact your nearest Schneider Electric sales office for this option. Controlled Panels Add these Control options to the basic OR panel. Type of control M Mechanical interlock P PLC interlock K Interposing contact (limit of four circuits) N Non-interposing contact D No controls or contactors Total number of circuits in the panel Enter 1 thru 8
3-4
6 7
Basic OR Panel Transformer kVA 3 3 (maximum 277 volt primary) 5 5 7 7.5 10 10 15 15 25 25 Panel mounting F Flush S Surface Main circuit breaker Primary and secondary voltage 5 kVA 7.5 kVA 10 kVA 1 120 60 A 80 A 100 A 2 208 30 A 45 A 60 A 3 240 30 A 40 A 60 A 4 277 25 A 35 A 45 A 5 480 15 A 20 A 30 A Type of panel A Low profile transformer (6 in.) T Standard transformer (8 in. or 12 in.) Type of panel circuit breakers S Plug-in QO B Bolt-on QOB Total number of circuits # 8 standard16 maximum
15
MEDICAL PRODUCTS
Schneider Electric has a variety of designs for Controlled Panels with more than 8 circuits. For more information, contact your nearest Schneider Electric sales office. Total number of circuits HOT at one time 1 Minimum Note: Recommended four maximum Output ampere 20 to 60 A maximum
10 11
For Chicago-code ground for ALL panels, add C as the Catalog No. suffix.
International and special voltage codes available. For other options including IN USE Light Control Panels, contact your nearest Schneider Electric sales office.
Table 15.3:
1 2 3 4 5 6 7 5 F 2 1 T S 12 5 kVA flush-mount, 208 V primary, 120 V secondary, standard transformer, snap-in, 12 circuits
15-2
Duplex Panels
Class 4800 / Refer to Catalog 4800CT0301 or Pricing Document 4800PL0301
www.schneider-electric.us
The Duplex Isolation Power Panel is a single enclosure containing two complete 120 V secondary hospital isolation systems. A divider in the units backbox separates the systems from top-to-bottom and front-to-back. Each system has its own set of equipment:
Primary circuit breaker Square D brand isolation transformer Reference ground bus bar Square D brand Iso-Gard line isolation monitor (LIM) Load center
Table 15.2:
1&2
Options
Transformer kVA 5 7 10 Panel mounting F S Primary and secondary voltage 1 2 3 4 5 Chicago-type ground C 120 208 240 277 480 Leave blank for standard ground 5 7.5 10 Flush Surface Main circuit breaker 7.5 kVA 80 A 45 A 40 A 35 A 20 A
4, 5, 6, & 7
5 kVA 60 A 30 A 30 A 25 A 15 A
10 kVA 100 A 60 A 60 A 45 A 30 A
15-3
15
MEDICAL PRODUCTS
Medical Products
Square D brand surgical facility panels combine several required operating room components in an economical, UL Listed package. Isolated power centers, power outlets, time clocks and controls, and X-ray film viewers are grouped together in one enclosure that can be easily installed and maintained. When installed separately, these items require expensive labor and take up valuable surgical suite space.
Standard Equipment
Square D brand Iso-Gard line isolation monitor (LIM) Primary main circuit breaker Secondary branch circuit breakers(16) 20 A, 2-pole Ground bar 5 kVA, 7.5 kVA, or 10 kVA isolation transformer AM/FM/cassette stereo system AM/FM/CD (single or multi-play) stereo system Twin X-ray film illuminator Portable X-ray film illuminator Portable X-ray receptacle Digital or dial clocks and timers Power receptaclessingle, duplex, or locking type Hospital Use Only Ground jacks
Optional Equipment
15
MEDICAL PRODUCTS
Table 15.2:
Table 15.3:
Isolation Transformers
Description Main Circuit Breaker 60 A 30 A 30 A 25 A 15 A 80 A 45 A 40 A 35 A 20 A 100 A 60 A 60 A 45 A 30 A
Position Qty. Description 1 1 5XR21 isolation transformer (5.0 kVA, 208120 V) 2 4 Duplex receptacles (specify color when ordering) 2 4 Ground jacks 3 1 MCT12B dual display digital clock/timer 3 1 MCTCT remote control 4 1 Double size film illuminator 4 1 AM/FM/CD single player c Note use of spacing and position numbering to complete the catalog number.
5XR11, 5.0 kVA, 120120 V 5XR21, 5.0 kVA, 208120 V 5XR31, 5.0 kVA, 240120 V 5XR41, 5.0 kVA, 277120 V 5XR51, 5.0 kVA, 480120 V 53040BB Backbox (42 in. H x 56 in. W x 8 in. D) 7XR11, 7.5 kVA, 120120 V 7XR21, 7.5 kVA, 208120 V 7XR31, 7.5 kVA, 240120 V 7XR41, 7.5 kVA, 277120 V 7XR51, 7.5 kVA, 480120 V 53032BB Backbox (42 in. H x 56 in. W x 12 in. D) 10XR11, 10.0 kVA, 120120 V 10XR21, 10.0 kVA, 208120 V 10XR31, 10.0 kVA, 240120 V 10XR41, 10.0 kVA, 277120 V 10XR51, 10.0 kVA, 480120 V 53059BB Backbox (42 in. H x 56 in. W x 12 in. D)
15-4
Medical Products
www.schneider-electric.us
The dual output voltage hospital isolation panel is a single ungrounded hospital isolation panel that can supply two different output voltages simultaneously. Similar to a standard distribution panel or load center, it can supply either 208/120 or 240/120 volts of ungrounded, isolated, Table 15.1: Interior
Description (1) Primary voltage 2 = 208 V 3 = 240 V 4 = 277 V 5 = 480 V (2) Output voltage A = 120/208 V B = 120/240 V (3) Size rating of 120 V secondary winding (kVA)a 5 = 5.0 kVA 7 = 7.5 kVA 1 = 10.0 kVA (4) Number of 30 A green ground receptacles 0 = None 1 = One 2 = Two 3 = Three 4 = Four 5 = Five 6 = Six (5) Number of 120 V power receptacles 0 = None 1 = One 2 = Two 3 = Three 4 = Four 5 = Five 6 = Six (6) Type of 120 V power receptacles 0 = No 120 V receptacles R = 20 A, red hospital grade duplex I = 20 A, ivory hospital grade duplex B = 20 A, black hospital grade duplex T = 20 A, brown hospital grade duplex L = 20 A, black hospital-only locking type receptacle (Hubbell #23000HG or equivalent) (7) Configuration of 208 or 240 V receptacle #1b 0 = No 208 or 240 V receptacle X = Hubbell #IN16 494 (equivalent to Hubbell #25603) A = NEMA Type #6-15R B = NEMA Type #6-20R C = NEMA Type #6-30R D = NEMA Type #6-50R E = NEMA Type #L6-15R F = NEMA Type #L6-20R G = NEMA Type #L6-30R (8) Configuration of 208 or 240 V receptacle #2b 0 = No 208 or 240 V receptacle X = Hubbell #IN16494 (equivalent to Hubbell #25603) A = NEMA Type #6-15R B = NEMA Type #6-20R C = NEMA Type #6-30R D = NEMA Type #6-50R E = NEMA Type #L6-15R F = NEMA Type #L6-20R G = NEMA Type #L6-30R a 120 V section of panel interior will be factory loaded with 8-20/2 branch breakers. This panel section is field expandable to 16 branch breakers by ordering additional circuit breaker catalog numbers QO220. b 208 V or 240 V section of panel interior will be factory loaded with the correct circuit breaker to match the selected receptacle. If no receptacle is selected, this section of the panel interior is field expandable to 2 branch breakers by ordering catalog number QO220 through QO260. Note: Total transformer kVA rating is the sum of the 120 V winding and the 208 V (or 240 V) winding.
single phase power using only one isolation transformer. Other hospital isolation panels can supply only one output voltage. The panel is ideally suited for renovation or surgical center projects. Transformer
Primary Voltage 208 208 240 240 277 277 480 480 208 208 240 240 277 277 480 480 208 208 240 240 277 277 480 480 Secondary Voltages 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 208/120 240/120 Catalog No. DVT522 DVT523 DVT532 DVT533 DVT542 DVT543 DVT552 DVT553 DVT722 DVT723 DVT732 DVT733 DVT742 DVT743 DVT752 DVT753 DVT122 DVT123 DVT132 DVT133 DVT142 DVT143 DVT152 DVT153
Table 15.2:
120 V Winding Rating (kVA) 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
Table 15.3:
Catalog No. DVC
Trim
Table 15.4:
Catalog No. DVBF DVBS
Backbox
Description flush mount surface mount Dimensions 62 in. H x 34 in. W x 12 in. D 64 in. H x 36 in. W x 12 in. D
NOTE: The NEC requires audible and visual alarm indication where isolation power is used (NEC 517-160).
15-5
15
MEDICAL PRODUCTS
Medical Products
Accessories Panel
The Accessories Panel accommodates options typically found in the operating room environment, including receptacles, clock/timers, and music centers. Other options include relays for controlling IN USE lights for laser and X-ray. Table 15.1: Ordering Information Table 15.3:
Catalog No. IA13C IA14CI IA15CI IA16CI IA17CI IA18CI IA19CI IA20CI IA21CI IA22CI IA23CI IA24CI
Accessories
Class 4800 / Refer to Catalog 4800CT0301 or Pricing Document 4800PL0301
www.schneider-electric.us
Unit Part Number Component Number Base Price Catalog Number AP Clock/timer CT MCT12B CR MCTCT CB MCTBP ST MCT14B SR MCT4RC Remote alarm indicator IA IA1C MA M5IAI MM MMIAI RA RA1 Music center RC AM/FM cassette RP AM/FM/CD single play CD player RM AM/FM/CD multi-play CD player Receptacles (Maximum of 8) A-# 520R (duplex red) B-# 520R (single red) C-# 620R D-# L620R E-# 630R F-# L630R G-# Hubbellock X-# X-ray S-# Special Ground jacks N-# 18 Relay (For use with controlled power panels only) R-# Ice cube relay (116)
53021BB
53011BB
Table 15.4:
Description 1/4 A fuse (Wickman TR5T) 2 mA meter 5 mA meter Fuseholder/cap (black) 1/4 A fuse (glass fuse) Green LED Red LED Yellow LED Interior only for 1A-1C (no trim) SAFE/SILENCE assembly for remote alarm HAZARD/PUSH-TO-TEST assembly for remote alarm HAZARD assembly for remote alarm SAFE/SILENCE replacement lens HAZARD/PUSH-TO-TEST replacement lens HAZARD replacement lens Buzzer only for remote alarm Accessory E booster power supply for three or more remote indicator alarms.
Table 15.5:
Digital
Clock/TimersUL
Listed
Catalog No.
Description
Instructions: Combine the unit part numbers to build the desired panel. The catalog number must begin with AP and corresponding number to follow. For example, APCTCRMARMA4N4 will produce a panel containing a MCT12B clock/timer with a MCTCT remote control, a M5IAI remote alarm indicator, a AM/FM/CD multi-play music center, four HBL8310R receptacles, and four SLR3 ground jacks. The purchase price includes the appropriate backbox. Some components may not be able to be installed with others, and may be considered as special items. Contact your nearest Schneider Electric sales office for all special item pricing. Table 15.2: X-ray Indicator/Receptacle Module Supervisory Module for Controlled Panels
Dimensions Catalog No. 13 in. H x 9.5 in. W Trim XRIAI 13 in. H x 9.5 in. W Trim XRIADI 12 in. H x 8 in. W x 4 in. D 53007BB 13 in. H x 11 in. W Trim 8CIIAI 12 in. H x 10 in. W x 6 in. D 53004BB
Dual display clock/timer Clock/timer with separate displays MCT12B Rechargeable battery pack for MCT12B (Optional) MCTBP Remote control unit w/ rechargeable battery pack for MCTCT MCT12B (Optional) Stainless steel trim plate MCTS95135 Backbox to be used with MCT95135 53007BB Clock/timer complete with backbox and trim MCT12BC Note: A complete clock/timer can be ordered using the catalog number MCT12BC. This includes the clock/timer, stainless steel trim and backbox. Remote control or battery pack must be ordered separately. Note: The battery pack and remote control do not work together. Surgical Chronometer Clock and three timers MCT14B Backbox 53006BB Auxiliary control MCT4RC Backbox 53008BB Chronometer complete MCT14BC Note: A complete surgical chronometer can be ordered using catalog number MCT14BC. This includes the chronometer, Remote control and both backboxes. All of these items are required for one complete unit.
15
MEDICAL PRODUCTS Surgical Chronometer MCT14B
Description Receptacle & indicator module Receptacle & indicator module w/ switch Backbox Remote push button station and alarm a Backbox
Table 15.6:
Receptacles quoted include a Hubbell 50/60 A, X-ray type 25000. For other receptacles, indicate the NEMA configuration after the Catalog Number. For example, XRIADINEMAL630R Table 15.3:
Catalog No. IA2CI IA3CI IA4CI IA5CI IA6CI IA7CI IA8CI IA9CI IA10CI IA11CI IA12CI
Single gang remote with meter display Included with all new panels
53007BB
53005BB
Green, amber, and red indicating lights and audible alarm mounted on front trim Green, amber, and red indicating lights, PUSH-TO-TEST button, audible alarm, and Panel-mounted ORICA5C in the room milliammeter mounted on front trim a Wall-mounted backbox not supplied. Panel-mounted IA1C Fits standard 2 gang box (3.5 in. deep) outside the room Wall-mounted 53008BB backbox required Panel-mounted M5IAI (backbox 4 in. H x 12 in. W x 4 in. D) a outside the room Wall mounted backbox not supplied. Panel-mounted M5IAI50 Fits standard 4 gang box (3.5 in. deep) a outside the room Note: PUSH-TO-TEST option for any of the above remotesadd PTT after the catalog number. a Includes meter for 5 mA LIM. For 2 mA LIM applications, change to catalog number ORICAC. 2 mA analog meter available. Contact Schneider Electric.
15-6
Table of Contents
Section 16
NEMA Contactors and Starters
NEMA AC Magnetic Contactors and Starter/Catalog
Numbering System 16-12
ContactorsNEMA Rated
Non-Reversing Class 8502 Reversing Class 8702 TeSys U Simple Motor Starter Vacuum, Low Voltage, Non-Reversing Class 8502 Vacuum, Low Voltage, Reversing Class 8702
NEMA Rated Type S Contactors and Starters (p. 16-13)
Duplex Motor Starters Class 8941 Enclosures Class 9991 External Reset Mechanisms Class 9065
Lighting Contactors (p. 16-64)
Factory Modifications (Forms) Lighting Contactors Class 8903 Manual Starters and Switches Class 2510, 2511, 2512 Multispeed Starters Class 8810 Overload Relays
Bimetallic Class 9065 Melting Alloy Class 9065 Motor Logic/Motor Logic Plus Class 9065 TeSys T Motor Management System
Pump Panels
Full Voltage Class 8940 16-81
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Additional Products
Electro-Mechanical Reduced Voltage Starter (see Supplemental Digest)
Accessories Class 9998, 9999 Renewal Parts Class 9998 Thermal Units Reversing Drum Switches Class 2601
16-1
16
Manual Starters
Fractional Horsepower Manual Starters with Melting Alloy Type Thermal Overload Relay
Table 16.1: Single-Unit TypesClass 2510Rated 16 A Thermal Units Prices shown do not include thermal units. Standard trip thermal units are $21.50 each. See page 16-125 for selection information.
NEMA 1 General Purpose Enclosure Surface Mounting No. of Poles Features Standard Oversized General Purpose Flush Mounting (Without Pull Box) Standard Stainless Steel Flush Plate Type $ Price Jumbo Stainless Steel Flush Plate Type $ Price NEMA Type 4a Watertight and Dusttight Enclosure NEMA Types 3R, 7 & 9 Hazardous Locations Div. 1 & 2 Class I Groups B, C, & D & Class II Groups E, F & G Enclosure Type $ Price
Open Type
Type of Operator
Type
$ Price
Type
$ Price
Type
$ Price
Type
Basic StarterClass 2510 Standard FG1 86.00 FGJ1 99.00 FF1 78.00 FS1 83.00 FO1 1 With Red Pilot Lightc FG1P 129.00 FGJ1P 143.00 FF1P 122.00 FS1P 129.00 FSJ1P 149.00 FO1P Toggle 99.00 FO2 Standard FG2 99.00 FGJ2 116.00 FF2 93.00 FS2 2 FO2P With Red Pilot Lightc FG2P 143.00 FGJ2P 158.00 FF2P 120.00 FS2P 143.00 FSJ2P 165.00 Standard FG3 116.00 FGJ3 129.00 FF3 107.00 FS3 114.00 FO3 1 With Red Pilot Lightc FG3P 158.00 FGJ3P 171.00 FF3P 149.00 FS3P 158.00 FSJ3P 179.00 FO3P Key Standard FG4 129.00 FGJ4 143.00 FF4 122.00 FS4 129.00 FO4 2 With Red Pilot Lightc FG4P 171.00 FGJ4P 185.00 FF4P 165.00 FS4P 171.00 FSJ4P 192.00 FO4P Starter with Handle Guard/Lock-OffClass 2510 Standard FG5 99.00 FGJ5 114.00 FW1 320.00 FR1 350.00 1 b With Red Pilot Light c FG5P 143.00 FGJ5P 158.00 FW1P 435.00 Order basic starter plus Toggle separate handle guard kit. Standard FG6 116.00 FGJ6 129.00 FW2 336.00 FR2 363.00 2 b With Red Pilot Lightc FG6P 158.00 FGJ6P 171.00 FW2P 449.00 a Furnished with one 3/4" pipe tap in bottom (reversible for top feed). To obtain 3/4" pipe tap top and bottom, add suffix letter H to type number and add $19.10 to price. b For replacement starter, order open type above. For NEMA 4 with pilot light, retain pilot light mounting bracket from original device.
1 1 1 1
1 1
Table 16.2:
Type of Operator
Features
One Starter in Duplex EnclosureClass 2510 Standard Toggle 2 With Red Pilot Light c Key 2 With Red Pilot Light c Two Starters in One EnclosureClass 2510 2 Standard Toggle Each Str. With Red Pilot Light on Eachc Key 2 Ea. Str. With Red Pilot Light on Eachc Starter and AUTO-OFF-HAND SPDT Selector Switch (AC Only)Class 2510 Standard 1 With Red Pilot Light c Toggle Standard 2 With Red Pilot Lightc Key 2 With Red Pilot Lightc
FG02 FG02P FG04P FG22 FG22P FG44P FG71 FG71P FG72 FG72P FG74P
FF22 FF22P FF44P FF71 FF71P FF72 FF72P FF74P
1 1
2 2
1 1 1 Replacement Starter Class 2510 86.00 129.00 129.00 99.00 143.00 143.00 2
Table 16.3:
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Type FG2P
Volts
115230 277
1 1
Table 16.4:
Enclosed Open (UL Listed) File E42243 (UL Component Recognized) CCN NLRV CSA Certified File LR25490 Class 3211-05
Type FO2
Table 16.5:
Class Number Type Number
How to Order
Catalog Number Class Type 2510 FG1
To Order Specify:
16-2
CP1
Discount Schedule
Manual Switches
www.schneider-electric.us
000
Table 16.6:
Non-ReversingClass 2510
NEMA 1 General Purpose Enclosure Surface Mounting Features Standard Oversized General Purpose Flush Mounting (Without Pull Box) Gray Flush Plate Standard Stainless Steel Flush Plate Jumbo Stainless Steel Flush Plate NEMA Type 4 a Watertight and Dusttight Enclosure NEMA Types 3R, 7 & 9 a Hazardous Locations Div. 1 & 2 Class I Groups B, C & D & Class II Groups E, F, and G Enclosure
Type of Operator
No. of Poles
Open Type
Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price Standard KG1 66.00 KGJ1 81.00 KF1 59.00 KS1 66.00 KW1 314.00 KR1 342.00 With Pilot Lightc 2 115 Vac KG1A 138.00 KGJ1A 153.00 KF1A 131.00 KS1A 138.00 KSJ1A 161.00 KW1A 428.00 230 Vac KG1B 138.00 KGJ1B 153.00 KF1B 131.00 KS1B 138.00 KSJ1B 161.00 KW1B 428.00 Standard KG2 149.00 KGJ2 165.00 KF2 143.00 KS2 149.00 KW2 386.00 KR2 442.00 With Pilot Lightc 3 208-277 Vac KG2B 221.00 KGJ2B 234.00 KF2B 215.00 KS2B 221.00 KSJ2B 243.00 KW2B 500.00 440-600 Vac KG2C 221.00 KGJ2C 234.00 KF2C 215.00 KS2C 221.00 KSJ2C 243.00 KW2C 500.00 Toggle Standard KG5 78.00 KGJ5 93.00 KW5 327.00 With Pilot Lightc 2 115 Vac KG5A 149.00 KW5A 440.00 230 Vac KG5B 149.00 KW5B 440.00 Standard KG6 162.00 KGJ6 176.00 KW6 396.00 With Pilot Lightc 3 208-277 Vac KG6B 233.00 KW6B 512.00 440-600 Vac KG6C 233.00 KW6C 512.00 Standard KG3 95.00 KGJ3 110.00 KF3 89.00 KS3 95.00 With Pilot Lightc 2 115 Vac KG3A 167.00 KGJ3A 179.00 KF3A 161.00 KS3A 167.00 KSJ3A 185.00 230 Vac KG3B 167.00 KGJ3B 179.00 KF3B 161.00 KS3B 167.00 KSJ3B 185.00 Key Standard KG4 179.00 KGJ4 192.00 KF4 171.00 KS4 179.00 With Pilot Lightc 3 208-277 Vac KG4B 251.00 KGJ4B 264.00 KF4B 243.00 KS4B 251.00 KSJ4B 270.00 440-600 Vac KG4C 251.00 KGJ4C 264.00 KF4C 243.00 KS4C 251.00 KSJ4C 270.00 a Furnished with one 3/4" pipe tap in bottom (reversible for top feed). To obtain 3/4" pipe tap top and bottom, add suffix letter H to type number and add $28.70 to price. b When replacing starter with pilot light in NEMA 4 enclosure, retain pilot light mounting bracket from original device.
Type KO1 KO1A b KO1B b KO2 KO2B b KO2C b KO5 KO5Ab KO5Bb KO6 KO6Bb KO6Cb KO3 KO3A KO3B KO4 KO4B KO4C
$ Price 52.00 125.00 125.00 120.00 207.00 207.00 64.00 120.00 120.00 147.00 219.00 219.00 81.00 153.00 153.00 165.00 234.00 234.00
Table 16.7:
Type of Operator
ReversingClass 2511
No. of Poles Motor Types for Which Suitable Features (Including Mechanical Interlock) Standard With Pilot Light:c 115 Vac 230 Vac Standard With Pilot Light:c 110120 Vac 208220 Vac 440600 Vac NEMA 1 General Purpose Enclosure Surface Mounting Type KG11 KG11A KG11B KG22 KG22A KG22B KG22C $ Price 287.00 399.00 399.00 441.00 557.00 557.00 557.00 With Flush Plate for Cavity Mounting (Without Pull Box) Type KF11 KF11A KF11B KF22 KF22A KF22B KF22C $ Price 270.00 386.00 386.00 428.00 543.00 543.00 543.00 Replacement Switch Class 2510 Type KO1T KO1AT KO1BT KO2T KO2AT KO2BT KO2CT $ Price 66.50 138.00 138.00 149.00 221.00 221.00 221.00
2 Toggle 3
Single 3-Lead Repulsion-Induction Three ; Also Single Capacitor, Split , or 4-Lead Repulsion-Induction
Table 16.8:
Type of Operator
Standard With 2 Pilot Lights:c 2 115 Vac 230 Vac Toggle Standard Three With 2 Pilot Lightsc: 3 Separate Winding 208240 Vac (Wye-Connected) 440600 Vac For green pilot light, add the letter G to the catalog number (i.e. 2510KW2CG). Single Two Winding (3-Lead)
Table 16.9:
Class 2510 KO1 KO3 KO2 KO4 KO5 KO6 No. of Poles
Table 16.11:
No. of Poles 2 3 2 Class 2512 3 3
115 230 460 575 90 115 230 Volts Volts Volts Volts Volts Volts Volts 2 2 2 2 2 7-1/2 3 7-1/2 3 10 7-1/2 15 3 10 10 20 1 1 1 1 2 2 2 2 1-1/2 1-1/2 1-1/2 1-1/2
Device
3 2 3
Class 2511
Table 16.10:
Class Number Type Number
How to Order
Catalog Number Class Type 2510 KO2
To Order Specify:
CP1
Discount Schedule
16-3
16
Single
OFF
.84 21 2.38 60
OFF
OFF
D
2.56 65
2.22 56 1.59 40
Types KO1, 1A, 1B, 2, 2B, 2C Types KO5, 5A, 5B, 6, 6B, 6C Motor Starting Switch
.75 .91 19 23
.50 13 .66 17
1.69 43
3 76 2.75 1.13 70 29
Table 16.13:
Device Type of Operator Toggle Dimensions Class 2510 Type FF1, 1P 2, 2P , FS1, 1P, 2, 2P FSJ1P, 2P FF3, 3P 4, 4P , FS3, 3P, 4, 4P FSJ3P, 4P A 1-7/16 1-7/16 1-7/16 1-7/16 1-3/4 1-3/4 1-3/4 1-3/4 B 2-3/4 3-1/2 2-3/4 3-1/2 2-3/4 3-1/2 2-3/4 3-1/2 C 4-1/2 5-1/4 4-1/2 5-1/4 4-1/2 5-1/4 4-1/2 5-1/4
OFF
.78 20
KF1, 1A, 1B, 2, 2B, 2C KS1, 1A, 1B, 2, 2B, 2C KSJ1A, 1B, 2B, 2C KF3, 3A, 3B, 4, 4B, 4C KS3, 3A, 3B, 4, 4B, 4C KSJ3A, 3B, 4B, 4C
Table 16.12:
Device Fractional Hp Starter Motor Starting Switch Class 2510 2510 Type FW1, 1P 2, 2P , KW1, 1A, 1B, 2, 2B, 2C
3.00 76
OFF
4.25 108
3.00 76
OFF
4.25 108
4.86 123
2.75 70 2.88 73 0.56 14 0.41 10 1.06 27 1.63 41 2.44 62
Pilot Light
1.63 41 2.88 73
0.71 18
3.28 83
Pilot Light
4.35 110
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
OFF
2.20 56
1.06 27
Pilot Light
3.09 78
16-4
2X .30 8
4.35 110
OFF
OFF
6.36 161
ON
2.56 65
PILOT LIGHT
5.75 146
OFF
D
1.19 30
.75 19 .91 23
Table 16.14:
Table 16.16:
Device
Type of Operator
3-3/4 5-1/4
Two Starters
PILOT LIGHT
OFF
OFF
2.75 70 2.88 73
.38 10
1.88 48
.56 14
3.81 97
2.56 65 2.63 67
Two Speed Toggle 2512 FF11, 11P, 22, 22P 5-1/4 3-3/4 5-1/4 Starter Two Speed KF11, 11A, 11B, Toggle 2512 5-1/4 3-3/4 5-1/4 Switch KF22, 22B, 22C c Dimensions include factory wired power connections. d Selector Switch is on left, extends 1-5/8" from mounting surface.
Table 16.15:
Device
16-5
16
Type of Class Type Operator Toggle 2510 FGO2, 02P One Starter Key 2510 FGO4P Toggle 2510 FG22, 22P Two Starters Key 2510 FG44P Toggle 2510 FG71, 71P, 72, 72P One Str. and One Sel. Sw. a Key 2510 FG74P Reversing Switchb Toggle 2511 KG11, 11A, 11B, 22, 22A, 22B, 22C Two Speed Starter Toggle 2512 FG11, 11P, 22, 22P Two Speed Switch Toggle 2512 KG11, 11A, 11B, 22, 22B, 22C a Selector switch is on left, increases overall depth to 3-1/2". b Only one pilot light (located on right) is used on Class 2511 switches.
Manual Starters
Types M and T integral horsepower manual starters provide convenient On-Off operation of small single phase, polyphase or DC motors. Typical applications include small machine tools, pumps, fans and conveyors.
Push button (M) or toggle (T) operators Reliable overload protection Pilot light and auxiliary contact available
Table 16.17: Integral Horsepower Manual Starters Note that the prices shown do not include thermal units. Standard trip thermal units are $21.50 each; see page 16-125 for selection information.
Non-Reversing Ratings No. of Poles NEMA Size NEMA 1 Surface Mounting Square Toggle P.B. Operator Operator Type MBG1 MCG1 MCG2 MBG2 MCG3 MBG4 MCG5 TBG1 TCG1 TCG2 TBG2 TCG3 TBG4 TCG5 Class 2510 NEMA 4/4X Watertight and Dusttight Enclosure Brushed Stainless Steel Type 264.00 MBW11b 336.00 491.00 MCW11 MCW12 $ Price Max. Voltage: 600 Vac a NEMA 4/4X NEMA 7 & 9 Watertight, For Hazardous Dusttight and Corrosion-Resistant Locations Class I Groups C, D Glass-Polyester Class II Enclosure Groups E, F & G Type $ Price 720.00 891.00 1089.00 770.00 941.00 720.00 891.00 Type $ Price NEMA 12 Dusttight and Driptight Industrial Use Enclosure Type $ Price 363.00 435.00 593.00 414.00 485.00 363.00 435.00 Open Type Square Toggle P.B. Operator Operator Type MBO1 MCO1 MCO2 MBO2 MCO3 MBO4 MCO5 TBO1 TCO1 TCO2 TBO2 TCO3 TBO4 TCO5 234.00 306.00 309.00 287.00 356.00 234.00 306.00
Motor Voltage
$ Price
$ Price
115 230 115 230 115 230 115 200-230 380-575 115 200-230 380-575 115 230 115 230
3 5 7-1/2 10
MBR1b 1004.00 MBA1b MCR1 MCR2 MBR2b MCR3 MCR5 1197.00 1382.00 MCA1 MCA2
DC 2Pole a b
NEMA 7 & 9 enclosures are cast-iron. NEMA 7 & 9 enclosures (cast aluminum) are available for outdoor use; to order these type of enclosures, replace the R in the catalog number with a T. For additional information, contact your local Square D Field Sales Office. Approved for group motor installations per NEC 430-53(c).
How to Order
Catalog Number Class Type 2510 MCA1
To Order Specify:
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-6
CP1
Discount Schedule
Manual Starters
www.schneider-electric.us
Table 16.19:
Class
Description
2511
Standard
3-Pole
Table 16.20:
Class
Description
Constant Hp 2
$ Price
Thermal Units
Starters will not operate without properly installed thermal units and device reset. Thermal unit must be installed so that markings face the front of starter.
OperatorAvailable with a push button or toggle operator in open and NEMA 1 versions. NEMA 4/4X (stainless) & 12 versions utilize a direct acting push button only. NEMA 4/4X (polyester) & 7/9 versions utilize an external toggle to actuate a push button device inside.
Application Data
SizeAvailable in NEMA Sizes M-0, M-1, and M-1P. PolesTwo poles single phase; three poles polyphase; 2 poles DC. Voltage600 volts AC max.; 250 volts DC max. Overload RelaysMelting alloy thermal overload relays have provisions for one Type B thermal unit for single phase starters and three Type B thermal units for three phase starters. All thermal units must be installed and the device reset before the starter contacts will operate. After overload relays have tripped, allow one or two minutes for the alloy to solidify before resetting.
Maintenance of Equipment
For proper performance, all equipment should be periodically inspected and maintained. Replacement contacts and interlocks are available in kit form to facilitate servicing and stocking. In addition, the service bulletin contains an exploded view of the device with components clearly marked for easy identification by description and part number. Mechanism Lock OffBoth open devices and starters in NEMA 1 surface and flush mounting, and NEMA 4, 4X, 7 & 9 and 12 enclosures can be locked in the OFF or STOP position. The NEMA 1 surface mounting, 4, 4X, 7 & 9 and 12 enclosures can also be locked closed to prevent unauthorized entry.
Table 16.21:
NEMA Size
2 or 3 2 or 3 2
CP1
Discount Schedule
16-7
16
A unique red pilot light assembly that clips into place is available factory installed on NEMA 1, 4, 4X, 12 and flush enclosures or as a field modification kit on the NEMA 1 surface or flush mounting enclosures. See page 16-9. The color cap assembly snaps into a knockout in the enclosure cover on the NEMA 1 enclosures. Pilot light kits are available for use on Various voltages (110-600 volts). Pilot light assemblies are not available for NEMA 7 & 9 enclosures.
Manual Starters
3.50 1.75 89
44 32
.28
7
4.03
102
1.25
START
5.13
130
STOP
RESET
1.13
29
5.72
145
.69
18
1.13
29
.44 Travel to
11 Reset
3.97
101
Class 2510 Type M Sizes M-0, M-1 and M-1P, Open Type Approximate Shipping Weight3 lbs.
.22
6
STOP
RESET
9.34
237
7.88
200
4.25
108
1.69 7.25
184
.75 8.94
227 19
3.38
86
43
1.28
33
.84
21
Classes 2511, 2512, Types M & T Sizes M-0 and M-1 NEMA 1 General Purpose Enclosure Approximate Shipping Weight9 lbs.
5.78 1.27
32 .75 Conduit Hub Top and Bottom
2.13
1.69
43 86
.88
22
.22
6
5.00
127
54
.22 1.06
27 6
3.91
99
1.02
26
3.25
83
147
1.31
33
.38
10
1.06
27
1.14
1.00
25
29
10.00
START
254
8.63
START
.47 10.75
273
RESET
12
219
STOP
STOP
RESET
8.13
207
RESET
5.75
146
10.00
254
10.92
277
1.44
1.00
25
1.00
25
37
.94
24
4.13 6.00
152 105 (1) .50 - .75 K.O. (2) .75 - 1.00 K.O. Top and Bottom
1.00
25
3.00 5.00
127 76
1.02
26
2.89
73
5.76
146
1.06
27
Class 2510 Type M & T Size M-1P NEMA 1 General Purpose Enclosure Approximate Shipping Weight5 lbs.
Class 2510 Types M & T Sizes M-0 and M-1 NEMA 1 General Purpose Enclosure Approximate Shipping Weight5 lbs.
Class 2510 Type M Sizes M-0, M-1 and M-1P NEMA 4/4X Watertight Stainless Steel Enclosure NEMA 12 Dusttight Industrial Use Enclosure Approximate Shipping Weight9 lbs.
5.78
147
6.50 .75
19 165 127
.75
19
6.41
163 33
6.00
152
5.00
1.28 1.69
43
.66
17
4.69
119
.34 9
6.13
156
R E ON S E T OFF
8.75
222
7.31 10.34
186 263 (2) .31 Dia. Mtg. Holes
(2) .31 Dia. Mtg. Holes
R ON E S E T OFF
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
.72
18
8.75
222
R ON E S E T OFF
10.50
267
9.94
252
12.13
308
3.69
94
.72
18
5.13
130
.81
21
1.69
43 .75 Conduit Hub In Top and Bottom
1.41
36
2.19
56
2.34
59
(1) .75 Conduit Top and Bottom (Std.) (1) 1.50 Conduit Top and Bottom (Max.)
Class 2510 Type M Size M-0 (ACDC) and Size M-1 (DC) NEMA 4/4X Watertight Corrosion-Resistant Glass Polyester Enclosure Approximate Shipping Weight6 lbs.
Class 2510 Type M Sizes M-1 and M-1P (AC) NEMA 4/4X Watertight Corrosion-Resistant Glass Polyester Enclosure Approximate Shipping Weight6 lbs.
Class 2510 Type M Sizes M-0, M-1 and M-1P NEMA 7 & 9 Hazardous Location Cast Iron Enclosure Approximate Shipping Weight18 lbs.
16-8
Table 16.22:
Description Handle Guard Kit with Padlock Provisiona Emergency Off Actuator Additional Key for Key Operated Devices a Standard on Type K devices.
Application
Type FF or FG, 115240 Vac/dc 9999PL10 9999PL10G 42.80 FWb b Lens cannot be replaced. Pilot light kits for NEMA 4 Enclosed Units are for replacement purposes only.
Table 16.24:
Description
Application
Nameplate Marking
1-3/4" x 2-13/16" Nameplate Standard commercial switch with Embossed Mounting box cover or flush plate, Holes for #6 Oval Head including Square D Screws stainless steel plates 1-29/32" x 3-27/32" Flat Nameplate with Mounting Holes for #6 Pan Head Screws Square D NEMA 1 surface mounted enclosure or gray flush plate
(Blank) (Special marking Specify marking desired.) (Blank) High Low Forward Reverse (Special marking Specify marking desired.)
Contact Kits
Table 16.25:
Description
See page 16-116 for Class 9998 Replacement Contact Kits. Table 16.27:
$ Price Description 71.00 Replacement Toggle Kits: Type FW and KW (NEMA 4) Type FR and KR (NEMA 7 & 9)
Factory Modifications and Forms Form Number P11f Price Addition 116.00
Replacement Parts
Class and Type 9998HW1 9998HR2 $ Price 29.30 30.90 57.00 57.00 57.00 57.00 57.00 14.30
Auxiliary X1 (1 N.O.) 158.00 99.00 Contactsd X2 (1 N.C.) Jumper N/A 9998SO31 14.30 Straps e Contactor Y76 No Charge N/A only c May only be field-added to NEMA 1 enclosures. For green pilot light, order 9999SPG1 additionally. d For proper operation, only one auxiliary contact kit per device may be added. e Used to control a single phase motor utilizing a three phase starter. f P11 Pilot Light Voltage Codes: 120 VV02 200/208 VV08 230 VV03 460 VV06 575 VV07 The pilot light Form P11 requires a voltage code. Catalog number example: 2510MBG1V02P11.
Replacement Handle Kits: NEMA 12 (Ser. B) Type MBA, MCA 9998HWA1 NEMA 4/4X (Stainless) (Ser. A & B) Type MBW, MCW 9998HWA1 NEMA 4/4X (Stainless) (Ser. C) Type MBW, MCW 31085-381-50 NEMA 4/4X (Polyester) Type MBW, MCW 9998HR3 NEMA 7 and 9 Type MBR, MCR 9998HR3 Internal Lever 9998IL1
Table 16.28:
Enclosures
Enclosure NEMA 1 Standard Catalog Number 9991EN1 9991MG1 9991MG2 9991FE1 9991KE1 9991KE2 9991KE3 $ Price 29.30 57.00 57.00 42.80 42.80 86.00 215.00
For use with Class 2510 Type F and K MSizes M0 & M1 MSize M1P FO1, FO1P, FO2, FO2P, FO3, FO3P , FO4, FO4P KO1, KO1A, KO1B, KO2, KO2B, KO2C, KO3, KO3A, KO3B, KO4, KO4B, KO4C, KO5, KO5A, KO5B, KO6, KO6B, KO6C
Table 16.26:
Class Number Type Number
How to Order
Catalog Number Class Type 9991 KE1
To Order Specify:
CP1
Discount Schedule
16-9
16
Type A and B
Class 2601 / Refer to Catalog 2510CT9701
www.schneider-electric.us
Class 2601 reversing drum switches may be used for across-the-line starting and reversing of AC polyphase, AC single phase or DC motors, where overload protection is not required or is provided separately. They are compact and inexpensive but ruggedly constructed. Drum switches are field convertible from maintained only to momentary only operation. This conversion consists of removing the handle screw and handle, turning the shaft 180 degrees, then replacing the handle and handle screw. Optional handles All devices offer as standard a one piece handle. An optional ball and shaft or fluted type handle is available. Drum switches with optional handles are available on a factory Quick-Ship basis only. To order, add the letter B or F to the type number, e.g., Class 2601 Type AW2B for a ball and shaft type, Class 2601 Type AW2F for a fluted type. Add $19.10 to the price for a fluted type, no adder for a ball and shaft type. (See photos below.) Table 16.29:
600 Vac Maximum Ratings NEMA 1 General Purpose Enclosure Type $ Price Class 2601 NEMA 4 Watertight and Dusttight Enclosure Type $ Price NEMA 3R Rainproof Outdoor Enclosure Type $ Price 360 Vdc Maximum NEMA 1 Maintained & Momentary a Type $ Price NEMA 13 Oiltight Flush Mounting Type $ Price
Type AG2
Voltage
Maximum Horsepower AC Single Phase 1-1/2 2 1-1/2 3 5 AC PolyPhase 2 2 5 7-1/2 DC 1/4 1/4 2 2
AG2
158.00
AW2
428.00
AH2
207.00
AG2S2
158.00
AF2
131.00
BG1
428.00
BW1
590.00
N/A
BG1S4
428.00
BF1
356.00
Approximate Dimensions
3.38
86
5.58
142
6.89
175
3.81
97
3.70
94
2.77
70
5.50
140
1.82
2.38
Type AW2
60
.20
5 (4) .17 Mounting Holes
3.20 .60
15 81
2.87
73
Optional Handles
4.50
114
2.68
3.26
2.91 4.61
4.86 3.53
5.12
130
3.25
83
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Fluted Type
2.94
75
4.00
102
.20
Table 16.30:
Class Number Type Number
How to Order
Catalog Number Class Type 2601 AG2
To Order Specify:
16-10
CP1
Discount Schedule
Motor Starters
www.schneider-electric.us
NEMA rated TeSys U motor starter is integrated, simple to choose and to install, consisting of a control unit snapped in a powerbase. NEMA rated TeSys U can be configured to fit specific applications as well. The NEMA Rated TeSys U uses the same optional accessories: reverser, current limiter, predictive maintenance options and communication options as the IEC TeSys U. To get details information about TeSys U, visit our web at www.us.schneider-electric.com/TeSysU.
Step 1
Power Base
Step 2
Control Unit
Step 3
Function Modules Auxiliary Contacts
Table 16.32:
Setting Range (Amps)
Power Base
Standard Advanced Advanced Advanced 3-phase $ Price 3-phase $ Price single-phase $ Price 3-phase $ Price Class 10 trip a Class 10 trip a Class 10 trip a Class 20 trip a 0.150.6 LUCAX6 120.00 LUCBX6 150.00 LUCCX6 150.00 LUCDX6 150.00 120.00 LUCB1X 150.00 LUCC1X 150.00 LUCD1X 150.00 0.31.4 LUCA1X 1.255.0 LUCA05 120.00 LUCB05 150.00 LUCC05 150.00 LUCD05 150.00 312 LUCA12 120.00 LUCB12 150.00 LUCC12 150.00 LUCD12 150.00 120.00 LUCB18 150.00 LUCC18 150.00 LUCD18 150.00 4.518 b LUCA18 832 b LUCA32 120.00 LUCB32 150.00 LUCC32 150.00 LUCD32 150.00 a Complete catalog number by adding appropriate code from voltage code table below. For example: LUCAX6FU. b Control units for 4.518 and 832 can be used ONLY with 32 amp rated power bases (LUB32 / LU2B32 / LUB32NR). c The control unit contains solid state overload relay and control power source for TeSys U. For more details on the different control units, their functions, and placement on the power base see page 18-29.
Table 16.33:
Voltage Codes
Volts 24 4872 110240 DC BLd AC B DC or AC ESe FU d DC voltage with range of 0.90 to 1.10 of nominal. e 4872 Vdc; 48 Vac
Table 16.34:
Control Unit
Terminals
Contact Indicates
Contact Normal Status N.O. N.C. N.O. N.O. 2 N.O. 1 N.O. and 1 N.C.
Off
Ready
Run
Catalog Number
$ Price
Auxiliary Contact
Ready condition Fault condition Ready condition Screw Fault condition Auxiliary Contact Function Modules Screw f g -
O I O O -
I I I O -
I I I O -
Accessories for LUB32/LUB32NR Current Limiter Reverser Line phase barrier Multifunction Control Unit Function modules Communication modules Soft Starter + TeSys U Powerbus Configuration and connection accessories
Quick Description Increases the breaking capacity to 130kA @ 460 V Stacked or side mounted Required for use as a self-protected combination starter (UL508E) Has functions for monitoring and predictive maintenance Fault differentiation, Thermal overload, Motor load indication Integrates into existing networks, major protocols available Use Altistart U01Soft Starter with TeSys U Use TeSys U with a prewired system PowerSuite software, busbar, external handle
For details & selection, see pages: 18-30 18-30 18-30 18-30 18-30 18-31 18-32 18-31 18-31
I11
Discount Schedule
16-11
16
2 N.C. Iindicates closed contact; Oindicates open contact Requires multifunction or advanced control unit plus fault differentiation module LUFDDA10.
Class 8536
General Classification 8502 8536 8538 8539 8702 8736 8738 8739 8810 8903 8940 8941 Contactor Page 16-13 Starter Page 16-17 Combination Starter with Disconnect Switch Page 16-30 Combination Starter with Circuit Breaker Page 16-34 Reversing Contactor Page 16-43 Reversing Starter Page 16-45
Type S C G - 3 V02
Numerals Used to designate specific, physical arrangements, such as number of poles, fuse clip size, etc.; but the numbering varies with Class of equipment. Consult Digest listings for specific device numbers.
Form S
Voltage Code AC operated devices without control transformer Code V01 V02 V06 V07 V08 Voltage/Frequency 24/60 120/60 or 480/60 or 600/60 or 208/60 110/50 440/50 550/50
Reversing Combination Starter with Disconnect Switch Page 16-50 Reversing Combination Starter with Circuit Breaker Page 16-52 Two Speed Starter Page 16-58 a Type S Lighting Contactors Page 16-65 a Pumping Plant Panel Page 16-81 a Duplex Controller Page 16-85 a
V81 - 480V Primary, 120V Secondary for units using a fused transformer control circuit Form (F4T). Design Type S NEMA Contactors and Starters Common Forms (factory modifications) Page 16-109 NEMA Size A B C D E F G H J Size 00 Size 0 Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 Size 7 M P Q V X Y Z J 30 Amperes 60 Amperes 100 Amperes 200 Amperes 300 Amperes 400 Amperes 600 Amperes 800 Amperes F4T FF4T H P1 8903 (only) A Bb C Start-Stop pushbuttons in the enclosure cover Bimetallic overload relays Hand-Off-Auto selector switch in the enclosure cover Fused transformer control circuit (primary fuses only) Fused transformer control circuit (primary & secondary fuses) Solid state overload relay Red ON pilot light in the enclosure cover This is only a partial listing consult Digest pages 16-13 and 16-110 for more information.
P2
S X01
Enclosure A F G H O R T W NEMA 12 Industrial Use NEMA 1 Flush Mounting General Purpose NEMA 1 General Purpose Surface Mounting NEMA 3R Rainproof Open Style Device (no enclosure) NEMA 7 & 9 Hazardous Environments, Spin Top NEMA 7 & 9 Hazardous Environments, Bolted NEMA 4 Watertight, 4X Corrosion Resistant
X10
Consult Digest pages 16-109 to 16-113 for additional form letters, When more than one form is applied to a single device, arrange Forms in alphabetical order.
Combination two speed starters will replace the S with a C, U or D. Pumping plant panels have Various leading characters. Not all use Type S contactors. Duplex controllers use N, C, U, and D. May also designate Motor Logic Plus overload relay
Table 16.35:
How to Order
To Order Specify: Catalog Number Class Number Voltage Class Type Form(s) Code Type Number Voltage Code Form(s) 8539 SCG44 V06 AH20P1X11 see pages 16-10916-113 Note: Description: NEMA Size 1, (10 Hp) Mag-Gard Combo Starter in a NEMA Type 1 enclosure with a 480V coil, start/stop pushbutton (A), class 20 SSOLR (H20), red pilot light (P1), 1 N.O. and 1 N.C. auxiliary contact (X11)
IMPORTANT - This information is intended for general interpretation of catalog numbers. Do not use to create catalog numbers for this product line. Note: The terms Type and Form do not appear in the catalog number.
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-12
General Information
Class 8502 / Refer to Catalog 8502CT9701
Class 8502 Type S magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Class 8502 contactors are available in NEMA sizes 00 through 7. Type S contactors are designed for operation at 600 Vac, 50 to 60 Hz. Table 16.36:
NEMA Size
Type 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 1-1/2 1-1/2 2 2 3 3 5 5 7-1/2 7-1/2 10 10 10 15 25 25 25 30 50 50 40 50 100 100 75 100 200 200 150 200 400 400 300 600 600
00
SAO12b
329.00
SAG12b
360.00
Use Size 0
SBO2b
414.00
SBG2b
446.00
SBW12b
945.00
27
SCO2b
485.00
SCG2b
518.00
SCW12b
1031.00
45
SDO2b
882.00
SDG2b
1031.00
SDW12b
1391.00
90
SEO2b
1425.00
SEG2b
1715.00
SEW12b
3167.00
135
SFO2b
3419.00
SFG2b
4022.00
SFW12b
6501.00
270
SGO2b
7451.00
SGG2b
8550.00
SGW12b
11685.00
540
SHO2b
20339.00
SHG2b
25172.00
SHW2b
32378.00
810
SJO2b
29028.00
SJG2b
33875.00
SJW2b
40995.00
a b
Size 6 and 7 are rated NEMA 4 only, painted sheet steel. Coil voltage code must be specified to order this product. Refer to standard voltage codes shown below.
Table 16.37:
60 Hz 24c 120d 208 240 277 480 600 Specify c
CP1
Discount Schedule
16-13
16
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8502SBO2V01S). d 120 Volt Polyphase contactors are wired for separate control Form S must be specified (i.e., order as 8502SCO2V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-109 Separate Enclosures (Class 9991). . . . . . . . . . . . . . . . . . . . . . . .page 16-102 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . .page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . .page 16-117
NEMA Size
Motor Voltage
Max. Hp
NEMA 7 & 9 Hazardous Locations Div. 1 & 2 Class I, Groups C & D Class II, Groups E, F, & G Bolted Type Cast Ironb Cast Aluminumd $ Price SPIN TOP Type $ Price
NEMA 12/3R a Dusttight & Driptight Industrial Use Enclosure Type $ Price
00
200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 a b c d
1-1/2 1-1/2 2 2 3 3 5 5 7-1/2 7-1/2 10 10 10 15 25 25 25 30 50 50 40 50 100 100 75 100 200 200 150 200 400 400 300 600 600
Use Size 0
Use Size 0
Use Size 0
Use Size 0
18
SBW22c
945.00
SBT2c
SBT42c
2070.00
SBR2c
2591.00
SBA2c
617.00
27
SCW22c
1031.00
SCT2c
SCT42c
2163.00
SCR2c
2705.00
SCA2c
689.00
45
SDW22c
2057.00
SDT2c
SDT42c
3482.00
SDR2c
4350.00
SDA2c
1344.00
90
SEW22c
3959.00
SET42c
5205.00
SER2c
2007.00
SEA2c
2084.00
135
SFW22c
8123.00
SFT42c
8415.00
SFR2c
10524.00
SFA2c
5247.00
270
SGT42c
18542.00
SGR2c
23178.00
SGA2c
11685.00
540
SHA2c
29016.00
810
SJA2c
37719.00
NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button. Coil voltage code must be specified to order this product. Refer to voltage codes shown on page 16-13. NEMA 7 and 9 bolted cast aluminum are not UL listed.
Auxiliary Units
Auxiliary contacts and power poles can be added by the factory or in the field on all Type S starters and contactors. The table below shows the maximum number of auxiliary units (in addition to the holding circuit contact) that can be added to a given size starter or contactor. In addition, it is possible to add a second internal contact on NEMA Size 0, 1, and 2 contactors and starters. Table 16.39:
NEMA Size 00 0, 1 and 2 Type SA SB SC SD SE SF SG SH SJ No. of Poles of Basic Contactor 23 1, 2 or 3 4 or 5 25 (Size 3 and 4) 23 (Size 5) 23 Maximum Number of External Auxiliary Units (In addition to holding circuit contact) 4 single circuit auxiliary contacts (N.O. or N.C.) if second internal auxiliary contact is not used. 4 single circuit auxiliary contacts (N.O. or N.C.) 2 single circuit auxiliary contacts (N.O. or N.C.) plus 1 power pole adder (1 or 2 poles, N.O. or N.C.). 2 single circuit auxiliary contacts (N.O. or N.C.) 3 single circuit auxiliary contacts (N.O. or N.C.) 2 single circuit auxiliary contacts (N.O. or N.C.) plus 1 NEMA Size 0-1 or Size 2 power pole adder (1 or 2 poles, N.O. or N.C.) 3 single circuit auxiliary contacts (N.O. or N.C.) 2 single circuit auxiliary contacts (N.O. or N.C.) plus 1 NEMA Size 01 or Size 2 power pole adder (1 or 2 poles, N.O. or N.C.)
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
3, 4 and 5 6 and 7
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Separate Enclosures (Class 9991) . . . . . . . . . . . . . . . . . . . . . . . page 16-102 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16-14
CP1
Discount Schedule
Table 16.40:
NEMA Size
1-Pole Single Phase 0 1 2-Pole Single Phase 00 0 1 2 3 4 5 6 7 4-Pole Polyphase 0 18 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 3 3 5 5 7-1/2 7-1/2 10 10 10 15 25 25 25 30 50 50 40 50 100 100 3 3 5 5 7-1/2 7-1/2 10 10 SBO3b 527.00 SBG3b 561.00 SBW13b 1074.00 9 18 27 45 90 135 270 540 810 SAO11b SBO1b SCO1b SDO1b SEO1b SFO1b SGO1b SHO1b SJO1b 287.00 372.00 441.00 827.00 1310.00 3162.00 6852.00 17433.00 25452.00 SAG11b SBG1b SCG1b SDG1b SEG1b SFG1b SGG1b SHG1b SJG1b 318.00 404.00 476.00 975.00 1601.00 3765.00 7952.00 22266.00 30285.00 Use Size 0 SBW11b SCW11b SDW11b SEW11b SFW11b SGW11b SHW1b SJW1b 903.00 989.00 1998.00 3054.00 6245.00 11087.00 29388.00 37407.00 18 27 SBO5b SCO5b 329.00 399.00 SBG5b SCG5b 360.00 432.00 SBW15b SCW15b 860.00 945.00
27
SCO3b
599.00
SCG3b
633.00
SCW13b
1146.00
45
SDO3b
1139.00
SDG3b
1287.00
SDW13b
2712.00
90
SEO3b
1823.00
SEG3b
2114.00
SEW13b
3965.00
4 5-Pole Polyphase 0
135
SFO3b
4757.00
SFG3b
5360.00
SFW13b
8864.00
18
SBO4b
684.00
SBG4b
719.00
SBW14b
1229.00
27
SCO4b
755.00
SCG4b
788.00
SCW14b
1301.00
a b
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-23 Factory Modifications (Forms). . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Separate Enclosures (Class 9991). . . . . . . . . . . . . . . . . . . . . . . page 16-102 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . page 16-117
CP1
Discount Schedule
16-15
16
200 10 230 15 SDO4b 1710.00 SDG4b 460 25 575 25 200 25 230 30 3 90 SEO4b 2735.00 SEG4b 460 50 575 50 200 40 230 50 4 135 SFO4b 6579.00 SFG4b 460 100 575 100 Size 6 and 7 are rated NEMA 4 only, painted sheet steel. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed on page 16-13. 2 45
1857.00
SDW14b
3281.00
3024.00
SEW14b
4877.00
7182.00
SFW14b
10688.00
www.schneider-electric.us
NEMA Size
Motor Voltage
Max. Hp
1-Pole Single Phase 0 1 18 27 115 230 115 230 1 2 2 3 SBT5c SCT5c SBT45c SCT45c 1979.00 2070.00 SBR5c SCR5c 2475.00 2591.00 SBA5c SCA5c 531.00 603.00
2-Pole Single Phase 00 0 1 2 3 4 5 6 7 9 18 27 45 90 135 270 540 810 115 230 115 230 115 230 115 230 1/3 1 1 2 2 3 3 7-1/2 Use Size 0 SBW21c SCW21c SDW21c 903.00 989.00 1998.00 SBT1c SCT1c SDT1c Use Size 0 SBT41c SCT41c SDT41c SET41c SFT41c 2021.00 2100.00 3402.00 5076.00 8139.00 Use Size 0 SBR1c SCR1c SDR1c SER1c SFR1c SGR1c 2528.00 2627.00 4257.00 6344.00 10175.00 22350.00 Use Size 0 SBA1c SCA1c SDA1c SEA1c SFA1c SGA1c SHA1c SJA1c 575.00 647.00 1287.00 1971.00 4991.00 11087.00 26112.00 34131.00
4-Pole Polyphase 0 18 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 3 3 5 5 7-1/2 7-1/2 10 19 10 15 25 25 25 30 50 50 40 50 100 100 3 3 5 5 7-1/2 7-1/2 10 10 10 15 25 25 25 30 50 50 40 50 100 100 a b c d SBW23c 1074.00 SBT3c 2199.00 SBR3c 2748.00 SBA3c 732.00
27
SCW23c
1146.00
2291.00
SCR3c
2867.00
SCA3c
804.00
45
SDW23c
2712.00
SDT3c
4199.00
SDR3c
5255.00
SDA3c
1601.00
90
SER3c
7604.00
SEA3c
2484.00
135
SFR3c
14283.00
SFA3c
7011.00
27
SCA4c
959.00
45
SDA4c
2169.00
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
90
SEA4c
3396.00
135
SFA4c
8837.00
NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Limited to 1 pilot light and a selector switch or Start-Stop push button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown on page 16-13. NEMA 7 and 9 bolted cast aluminum are not UL listed.
Coil Voltage Codes and page number reference for additional information are shown on page 16-13. For How to Order Information, see page 16-12.
16-16
CP1
Discount Schedule
General Information
Type S magnetic starters are used for full-voltage starting and stopping of AC squirrel cage motors. Motor overload protection is provided via melting alloy type thermal overload relays. Type S starters are available in NEMA Sizes 00 through 7, and are designed for operation at 600 Vac, 50 to 60 Hz.
These ambient insensitive overload relays are available on Sizes 00 through 6 and standard on size 7. They provide phase loss, phase unbalance protection. To order, add Form H10 (for Class 10), H20 (for Class 20), or H30 (for selectable trip class protection). For more information about MOTOR LOGIC, see pages 16-91, 16-111 and 16-112.
00
SAO12b
386.00
SAG12b
419.00
Use Size 0
Use Size 0
18
SBO2b
485.00
SBG2b
518.00
SBW12b
1017.00
SBW22b
1017.00
Schneider Electric offers express shipping for factory modified NEMA Type 1 and Type 12/3R Enclosed Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. Ask for Laser Delivery, then select the product and the modifications you need when you place your order. Its as easy as that!
27
SCO3b
557.00
SCG3b
590.00
SCW13b
1103.00
SCW23b
1103.00
45
SDO1b
1013.00
SDG1b
1160.00
SDW11b
2186.00
SDW21b
2186.00
90
SEO1b
1638.00
SEG1b
1929.00
SEW11b
3380.00
SEW21b
4226.00
135
SFO1b
3747.00
SFG1b
4350.00
SFW11b
6827.00
SFW21b
8535.00
270
SGO1b
9152.00
SGG1b
10254.00
SGW11b
15795.00
540
SHO2b
21756.00
SHG2b
28881.00
SHW2b
36003.00
810
SJO2b
31256.00
SJG2b
38381.00
SJW2b
45503.00
a b
Size 6 and 7 are rated NEMA 4 only, painted sheet steel. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below.
Table 16.43:
CP1
Discount Schedule
16-17
16
Code $ Price Adder 60 Hz 50 Hz 24c V01 No Charge 120d 110 V02 No Charge 208 V08 No Charge 240 220 V03 No Charge 277 V04 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 c 24 V coils are not available on Sizes 47. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8536SBO2V01S). d 120 Volt Polyphase contactors are wired for separate control. Form S (separate control) must be specified (i.e., order as 8536SCO2V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-109 Separate Enclosures (Class 9991). . . . . . . . . . . . . . . . . . . . . . . .page 16-102 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . .page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . .page 16-117
Voltage
Table 16.44: 3-Pole Polyphase600 Vac Maximum5060 Hz Note that prices shown do not include thermal units. Devices require 3 thermal units (Sizes 006). Standard trip thermal units are $21.50 each. See page 16-125 for selection information.
NEMA 7 & 9 For Hazardous Locations Div. 1 & 2 Class IGroups C, D Class IIGroups E, F, & G Bolted Type Cast Ironb 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 a b c d 1-1/2 1-1/2 2 2 3 3 5 5 7-1/2 7-1/2 10 10 10 15 25 25 25 30 50 50 40 50 100 100 75 100 200 200 150 200 400 400 300 600 600 Cast Aluminumd $ Price SPIN TOP Type $ Price NEMA 12/3Ra Dusttight & Driptight Industrial Use Enclosure
NEMA Size
Motor Voltage
Max. Hp
Type
$ Price
00
Use Size 0
Use Size 0
Use Size 0
18
SBT2c
SBT42c
2150.00
SBR2c
2690.00
SBA2c
689.00
27
SCT3c
SCT43c
2241.00
SCR3c
2804.00
SCA3c
761.00
45
SDT1c
SDT41c
3623.00
SDR1c
4527.00
SDA1c
1472.00
90
SET43c
5439.00
SER3c
6800.00
SEA1c
2298.00
135
SFT41c
8778.00
SFR1c
10971.00
SFA1c
5574.00
270
SGT41c
20970.00
SGR1c
26211.00
SGA1c
13386.00
540
SHA2c
32727.00
810
SJA2c
42227.00
NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Limited to 1 Pilot Light and Selector Switch or Start-Stop Push-Button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection Table 16.43 shown on page 16-17. NEMA 7 and 9 bolted cast aluminum are not UL listed.
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Separate Enclosures (Class 9991) . . . . . . . . . . . . . . . . . . . . . . . page 16-102 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
For How to Order Information, see page 16-12. Schneider Electric offers express shipping for factory modified NEMA Type 1 and Type 12/3R Enclosed Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. Ask for Laser Delivery, then select the product and the modifications you need when you place your order. Its as easy as that!
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-18
CP1
Discount Schedule
18
SBO3a
629.00
SBG3a
675.00
SBW13a
1229.00
SBW23a
1229.00
27
SCO4a
714.00
SCG4a
761.00
SCW14a
1301.00
SCW24a
1301.00
45
SDO2a
1283.00
SDG2a
1430.00
SDW12a
2910.00
SDW22a
2910.00
90
SEO2a
2096.00
SEG2a
2357.00
SEW12a
4206.00
135
SFO2a
5142.00
SFG2a
5715.00
SFW12a
9221.00
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed below.
Table 16.47:
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-109 Separate Enclosures (Class 9991). . . . . . . . . . . . . . . . . . . . . . . .page 16-102 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . .page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . .page 16-117
CP1
Discount Schedule
16-19
16
Code $ Price Adder 60 Hz 50 Hz 24b V01 No Charge 120c 110 V02 No Charge 208 V08 No Charge 240 220 V03 No Charge 277 V04 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 b 24 V coils are not available on Sizes 47. On sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8536SBO2V01S). c 120 Volt Polyphase starters are wired for separate control. Form S (separate control) must be specified (i.e., order as 8536SCO2V02S). Note: For voltage codes used with control transformers, see 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge.
NEMA Size
Motor Voltage
Max. Hp
Type
$ Price
NEMA Size
Motor Voltage
Max. Hp
Coil Voltage
$ Price
Type
$ Price
18
SBT3c
2348.00
SBR3c
2939.00
SBA3c
846.00
27
2433.00
SCR4c
3047.00
SCA4c
932.00
45
SDT2c
4797.00
SDR2c
6002.00
SDA2c
1742.00
90
135
SER2c
8679.00
SEA2c
2726.00
SFA2c
7370.00
NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Limited to 1 Pilot Light and Selector Switch or Start-Stop Push-Button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed on page 16-19.
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Separate Enclosures (Class 9991) . . . . . . . . . . . . . . . . . . . . . . . page 16-102 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16-20
CP1
Discount Schedule
SBTO2a
485.00
SCTO3a
557.00
SDTO1a
1011.00
Extra Capacity Single Phase Starters (Not NEMA Rated) 2-Pole Single Phase250 Vac Maximum5060 Hz
Table 16.51: Note that prices shown do not include thermal unit. Devices require 1 thermal unit. Standard trip thermal unit is $21.50 each. See page 16-125 for selection information.
Motor Voltage Max. Hp Open Type NEMA 1 General Purpose Enclosure Type SEG6a $ Price NEMA 3R Rainproof, Sleet Resistant, Outdoor Use Enclosure Type SDH8ab $ Price 1787.00 2091.00 NEMA 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure Type SEW16a $ Price 3176.00 NEMA 4X Watertight Corrosion Resistant Glass-Polyester Enclosure Type SEW26a $ Price 3969.00 NEMA 12/3R c Dusttight & Driptight Industrial Use Enclosure Type SEA6a $ Price 2091.00
1722.00 SEH6a
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. Uses a Size 3 overload relay. NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information.
Table 16.52:
Code $ Price Adder 60 Hz 50 Hz 24d V01 No Charge 120e 110 V02 No Charge 208 V08 No Charge 240 220 V03 No Charge 277 V04 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 d 24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified. e 120 Volt Polyphase starters are wired for separate control and must be ordered with Form S (i.e., 8536SCO2V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-23 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-109 Separate Enclosures (Class 9991). . . . . . . . . . . . . . . . . . . . . . . .page 16-102 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . .page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . .page 16-117
Voltage
CP1
Discount Schedule
16-21
16
NEMA Size
Load Voltage
Single Phase 115 200 230 380 460 575 115 200 230 380 460 575 115 200 230 380 460 575 115 230 1/2 1 1 2 2 3 3 5
PolyPhase 1-1/2 1-1/2 1-1/2 2 2 3 3 5 5 5 7-1/2 10 15 15 15 15 20 30 30 30 25 30 50 60 60 60 75 125 150 150 125 150 250 300 300 9 9 9 9 9 9 18 18 18 18 18 18 27 27 27 27 27 27 36 36 45 45 45 45 45 45 90 90 90 90 90 90 135 135 135 135 135 270 270 270 270 270 540 540 540 540 540 810 810 810 11 11 11 11 11 11 21 21 21 21 21 21 32 32 32 32 32 32 42 42 52 52 52 52 52 52 104 104 104 104 104 104 156 156 156 156 156 311 311 311 311 311 621 621 621 621 621 932 932 932 5 5 5 10 10 10 15 15 15 24 24
Single Phase 3 6 12 15
KVAR
00
1P
115 3 2 200 10 230 7-1/2 15 5 2 380 25 460 25 575 25 115 200 25 230 30 3 380 50 460 50 575 50 200 40 230 50 4 380 75 460 100 575 100 200 75 230 100 5 380 150 460 200 575 200 200 150 230 200 6f 380 300 460 400 575 400 230 300 460 600 7f 575 600 Tables and footnotes are taken from NEMA Standards. a
Ratings shown are for applications requiring repeated interruptions of stalled motor current or repeated closing of high transient currents encountered in rapid motor reversal, involving more than five openings or closings per minute and more than ten in a tenminute period, such as plug-stop, plug-reverse or jogging duty. Ratings apply to single speed and multi-speed controllers. Per NEMA Standards paragraph ICS 2-321.20, the service-limit current represents the maximum rms current, in Amperes, which the controller may be expected to carry for protracted periods in normal service. At service-limit current ratings, temperature rises may exceed those obtained by testing the controller at its continuous current rating. The ultimate trip current of over-current (overload) relays or other motor protective devices shall not exceed the service-limit current ratings of the controller. FLUORESCENT LAMP LOADS300 VOLTS AND LESSThe characteristics of fluorescent lamps are such that it is not necessary to derate Class 8502 contactors below their normal continuous current rating. Class 8903 contactors may also be used with fluorescent lamp loads. For controlling tungsten and infrared lamp loads, and resistance heating loads, Class 8903 AC lighting contactors are recommended. These contactors are specifically designed for such loads and are applied at their full rating as listed in the Class 8903 Section. Ratings apply to contactors which are employed to switch the load at the utilization voltage of the heat producing element with a duty which requires continuous operation of not more than five openings per minute. Class 8903 Types L and S lighting contactors are rated for resistance heating loads. When discharged, a capacitor has essentially zero impedance. For repetitive switching by a contactor, sufficient impedance should be connected in series to limit inrush current to not more than 6 times the contactor rated continuous current. In many installations, the impedance of connecting conductors may be sufficient for this purpose. When switching to connect additional banks, the banks already on the line may be charged and can supply additional available short-circuit current which should be considered when selecting the impedance to limit the current.
30 5 8.5 2.1 1.0 30 15.4 6.3 3.1 30 10 17 4.1 7.2 2.1 3.6 8 28 20 34 8.3 14 4.2 7.2 16 25 43 10.0 18 5.2 8.9 20 60 10 17 4.1 2.0 60 31 12 6.1 60 20 34 8.1 14 4.1 7.0 27 56 40 68 16 28 8.1 14 53 50 86 20 35 10 18 67 120 45 20 10 120 30 52 14 23 6.8 12 40 86.7 60 105 27 47 14 23 80 75 130 34 59 17 29 100 240 91 41 20 240 60 105 27 47 14 24 80 173 120 210 54 94 27 47 160 150 260 68 117 34 59 200 480 182 81 41 480 120 210 54 94 27 47 160 342 240 415 108 188 54 94 320 300 515 135 234 68 117 400 180 315 240 360 625 480 450 775 600 The ratings for capacitor switching above assume the following maximum available fault currents: NEMA Size 003: 5,000 A RMS Sym. NEMA Size 45: 10,000 A RMS Sym. NEMA Size 6: 18,000 A RMS Sym. NEMA Size 7: 30,000 A RMS Sym. Note: If available fault current is greater than these values, connect sufficient impedance in series as noted in the previous paragraph. f For NEMA Size 6 & 7, the operation rate is as follows: Continuous operation rate is 3 operations per minute maximum; Jogging or Plugging Duty operation rate is 15 operations per minute for a maximum of three minutes.
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
The motor ratings in Table 16.53 are NEMA standard ratings and apply only when the code letter of the motor is the same as or occurs earlier in the alphabet than is shown in the Table 16.54. Motors having code letters occurring later in the alphabet may require a larger controller. Consult Square D/ Schneider Electric CIC at 1-888-SquareD (1-888-778-2733). Table 16.54:
Motor Hp Rating 1-1/22 3571/2 & above Maximum Allowable Motor Code Letter L K H
16-22
Approximate Dimensions
Table 16.55:
NEMA Size 00 0 1 2 Type
A D E F C
G B
lbs. 4 4 4-1/2 6-3/4
H I
14
SEO
4 5 6 7
H B
RESET
Table 16.56:
00, 0, 1, 1P 0, 1 2 SAO SCO SBO SCO SDO
D E
SEO
F B
RESET
Pilot Light
4 5 6 7
62 85 140
G H I H
Figure 3
B E
Table 16.57:
NEMA Size 00 0 1 2 3 4 5 6 7 Type SAG SBG SCG SDG SEG SFG SGG SHG SJG
H
D 3 8-19/32 13 E 7/8 F 8-1/8 G 1 H I J 5 K L
15/16 4-1/8
G A
1-17/32 18-3/4 1-17/32 1-17/32 8-3/8 7-3/4 1-17/32 8-3/8 1-1/4 2-1/8 11 1-1/4 22-5/16 1-7/16 7/16 2-1/8 40 2-1/8 5-1/2 9/16
17-7/32 44-7/32 12-13/16 12-15/16 65-3/4 93 20-7/32 34-1/2 13-1/8 23-1/2 13-1/8 23-1/2
Figure 4
(4) I Dia. Mtg. Holes A H
64-1/2 2-5/16
Floor Mounting
B
RESET
Figure 5
16-23
16
Approximate Dimensions
Table 16.58:
NEMA Size Class
0 and 1
6-3/8 7-13/16 13-3/16 1-9/16 3-1/4 8-1/8 8-1/8 7-7/8 16-3/16 1-9/16 5 5 12
1-1/2'' Dia. Hub 2-1/2'' Dia. Hub 2-1/2" Dia. Hub 3-1/2" Dia. Hub (2) 3" Dia. Hub
I W X
J
3 and 4
18-5/32 8-3/4
3-11/16 26-23/32
2-9/16 3-3/16 7/16 3/4'' Dia. Hub 2-9/16 3-3/16 7/16 3/4" Dia. Hub 3-1/8 5-3/4 9/16 3/4" Dia. Hub
8536 SFW 8502 & SGW 8536 8502 & SHW 8536
All
12
30-1/2
7/8
4-1/2
26-23/32
All
46
5/8
4-19/32
28-5/16
6a 7a a
All
12
64
5/8
4-19/32 30-13/16 2-11/16 4-1/2 9/16 3/4" Dia. Hub Floor Mounting
H K
8502 & SJW All 34-1/2 23-1/2 101 8536 Size 6 and 7 are sheet steel enclosures, and are rated NEMA 4 only.
Table 16.59:
NEMA Size 0 and 1
13-1/2 19/32 3-3/16 18-13/16 1-21/32 2-5/16 5/16 13-1/2 19/32 15 15 3-7/8 18-13/32 1-21/32 2-5/16 5/16 20-7/8 20-7/8 2 2 2-5/8 2-5/8 5/16 5/16
12-5/8 7-13/16 14-11/16 2-9/16 7-1/2 14-7/8 14-7/8 7-9/16 8-1/4 16-5/16 16-5/16 2-9/16 9-3/4 2-9/16 9-3/4
2 8536 SEW 23 8502 Same as Standard NEMA 4 dimensions, see above. 3 SFW 23 and SEW 23 4 8536 Same as Standard NEMA 4 dimensions, see above. SFW 23 5 8502 & 8536 SGW All Same as Standard NEMA 4 dimensions, see above. 6b 8502 & 8536 SHW All Form F4T is supplied as standard. Refer to page 16-110. 7b 8502 & 8536 SJW All b Size 6 and 7 are sheet steel enclosures, and are rated NEMA 4 only.
Table 16.60:
Size Type SBW SCW SDW
0, 1 2
1-11/16 3-11/32
A D SIZE 2 ONLY E D G
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
F I C
(2) "L" DIA. MTG. HOLES (SIZE 1) (4) "L" DIA. MTG. HOLES (SIZE 2)
RESET
SIZE 2 ONLY G 1" CONDUIT HUB TOP & BOTTOM - SIZE 1 1 1/2" CONDUIT HUB TOP & BOTTOM - SIZE 2 3/4" CONDUIT HUB IN SIZE 1 & SIZE 2 H K
16-24
Approximate Dimensions
Table 16.61:
NEMA Size 0-2a 3-4b
A E
a With control power transformer (Form F4T) b Dimensions also for Form F4T. Note: Devices with Form F4T may use larger enclosure. Consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733) for dimensions.
.63 16
.63 16
12.70 322
8.25 210
(4) .42 Dia. Mtg. Holes 10 (1) 1-11 1/2 Pipe Tap at Bottom Standard
9.25 235
(4) .42 Dia. Mtg. Holes 10 (1) 1 1/2 - 11 1/2 Pipe Tap at Bottom Standard
Figure 2 Size 2
Table 16.62:
Conduit Sizes Loc. A, B, C & D NEMA Size 01 2 34 5 Std. 1-1/4 1-1/2 2-1/2 4
Top View
E Q R A Threaded Cover Enclosure Overload Reset Circuit Breaker Operator Handle - Combination Form Only (Add 1 IN to overall width) Space Required to Remove Bottom Cover G F B J T D M C
Rear Seal
K L
H S
16-25
16
Approximate Dimensions
Table 16.63:
NEMA Size 01 2 34 5 Type SBT SCT SDT SET SFT SGT
V U
L H N
Table 16.64:
NEMA Size 0 1 2 3 4 5 6 7 Type SBA SCA SDA SEA SFA SGA SHA SJA
A E
F C
30-1/2 1/2 46 64
Floor Mounting
Table 16.65:
NEMA Size 0 1 2 3 4 5 6 7
NEMA 12
Table 16.66:
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
D1
D2
G1
G2
H1
H2
All
8-27/32 12-9/32 7-1/8 1-3/8 1-7/16 6 7-1/2 2-19/32 2-3/16 2-1/16 2-5/8 14-9/32 1-3/8
1-3/8
1-7/8
4-3/8 1-27/32
F B
SDH
All
9-27/32 16-9/32 8-5/8 1-3/8 1-7/16 7 11-1/2 2-19/32 2-3/16 2-1/16 2-5/8 16-25/32 1-5/16 1-3/4
2-1/8
4-7/8 1-27/32
J X
M Y
SEH
All
12-27/32 25-9/32 8-5/8 1-3/8 1-7/16 10 20-1/2 2-19/32 2-3/16 2-1/16 2-5/8 19-25/32 1-5/16 1-15/16 2-7/16 6-3/8 1-27/32
X K L
H1 H2
NEMA 3R
SFH
All
12-27/32 40-9/32 9-1/8 1-3/8 1-7/16 10 35-1/2 2-19/32 2-3/16 2-1/16 2-5/8 20-9/32 1-5/16 2-5/16 2-11/16 6-3/8 1-27/32
16-26
600 Volt
Class 8502 / Refer to Catalog 8502CT9701
General Information
Class 8502 Type W non-reversing vacuum contactors used to switch capacitors, transformers and electric motors where overload protection is separately provided. Type W vacuum contactors are designed for operation at 600 Volts, 50/60 Hz. (See page 16-49 for Class 8702 Reversing Vacuum Contactors.) Table 16.67:
NEMA Size
200 230 4 135 1080 460 575 200 230 5 270 2160 460 575 200 230 6 540 4320 460 575 Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table below.
WFO3a
3965.00
WGO3a
8004.00
WHO3a
22383.00
Table 16.68:
Class 9998Replacement Coils for Class 8502 and 8702 Vacuum Contactors (Includes Rectifier)
Type Poles Class & Type 9998WF 9998WG 9998WH Suffix Number (Complete Coil Number Consists of Class and Type Followed by Suffix Number) 120 V 110 V 120 120 120 240 V 220 V 240 240 240 480 V 440 V 480 480 480 600 V 550 V 600 600 600 732.00 1724.00 1904.00 $ Price
Size
4 5 6
WF WG WH
3 3 3
Table 16.69:
Type WFWG WH WF WGWH WG WH
Table 16.70:
Volts 50 Hz 60 Hz 110 V02
3.60
Auxiliary Interlock 91
2.67 2.67
68 68
6.13
156 133 Line Term.
5.22
12.90
Overtravel Gauge
12.50 7.28
185 318
8.94
227
6.63
168
13.99
355
5.96
151
1.44 1.44
37
3.72
94
118
201
5.93
151
37
7.90
201
CP1
Discount Schedule
16-27
16
4.63
37
1.28
33
5.09
1500 Volt
Class 8502 / Refer to Catalog 8502CT9701
www.schneider-electric.us
The Class 8502 Type V vacuum contactor is a three-pole, 1500 V rated device which meets UL508 (1.5 kV) and CSA. Vacuum technology offers long life and low maintenance in a compact, lightweight design. The contactor is suitable for contaminated atmospheres because the main contacts are sealed in vacuum bottles. Also, since gravity is not used to assist contactor operation, the Class 8502 contactor may be mounted in any plane without special modifications. Type V vacuum contactors are designed for the control of inductive or non-inductive loads at voltages between 200 and 1500 Vac. Table 16.71:
NEMA Size
3.60
91
200 50 230 60 460 125 4 160 1080 575 150 VFO3a 800 200 1000 250 1500 400 200 100 230 125 460 250 5 320 2160 575 300 VGO3a 800 400 1000 1500 800 200 150 230 200 460 400 6 540 4320 575 400 VHO3a 800 1000 1500 1300 Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table below.
3965.00
8004.00
22383.00
Overtravel Gauge
Table 16.72:
Class 9998Replacement Coils for Class 8502 and 8702 (Contains Rectifier)
Type Poles Class & Type 9998WF 9998WG 9998WH Suffix Number (Complete Coil Number Consists of Class and Type Followed by Suffix Number) 120 Volts 110 Volts 120 120 120 240 Volts 220 Volts 240 240 240 480 Volts 440 Volts 480 480 480 600 Volts 550 Volts 600 600 600 $ Price
5.87
149 Front View Shown Without Overtravel Gauge
Size
4 5 6
VF VG VH
3 3 3
Table 16.73:
Type VFVG VH VF VGVH VG
6.63
168
1.44 1.44
37
VH
4.63
118
37
Table 16.74:
Volts 50 Hz 60 Hz 110 V02
550 V07
600 V07
7.00
178
14.00
1 Coil Terminal A 2 Coil Terminal C
6.75
356
8.00
203 Mtg.
8.94
227
171 Mtg. Line and Load Terminals: One .50 - 13 Tapped Hole Per Terminal
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
5.05 Load
128 1 2 Two Dual Circuit Auxiliary Contacts can be located on both sides of contactor. Coil Terminals B and D located on opposite side of contactor.
7.75
197
Two Dual Circuit Auxiliary Contacts can be located on both sides of contactor.
146 Std. 178 2 Coil Terminals B and D located on opposite side of contactor.
5.75
7.00
16-28
CP1
Discount Schedule
600 Volt
Class 8536 / Refer to Catalog 8538CT9701
General Information
Class 8536 Type W non-reversing vacuum starters are used to switch electric motors where overload protection is not separately provided. Type W vacuum starters are designed for operation at 600 Volts, 50/60 Hz. Starters are available exclusively with Motor Logic Feature Base Solid State Overload Relays. Table 16.75:
NEMA Size
200 40 230 50 4 135 1080 WFO3a 460 100 575 100 200 75 230 100 5 270 2160 WGO3a 460 200 575 200 200 150 230 200 6 540 4320 WHO3a 460 400 575 400 Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table at left.
10125.00
24008.00
Table 16.76:
Size
4 5 6
WF WG WH
Table 16.77:
Type WFWG WH WF WGWH WG
Table 16.78:
Volts 50 Hz 60 Hz 110 V02
8.59 1.13
29 218
4.30
109
3.28
83
8.59
218
.94
24
5.21
132
1.13
29
4.30
109
9.07
230
2.60
66
6.47
164
19.96
507
26.25
667 471
.42
11
18.56
17.77
13.06 12.21
310 332
451
11.20
284
16.37
416
Reset
Reset
.88 1.75
44 22
6 (Reset Travel)
.24
4.28
109
184
3.62 7.25
92
6 (Reset Travel)
.24
6 (Reset Travel)
7.84
199
8.74
222
CP1
Discount Schedule
16-29
16
.24
Class 8538 and 8539 Type S combination starters combine the requirements of motor overload and short circuit protection into one package. These starters are manufactured in accordance with NEMA standards and are UL Listed (although some Form numbers may not be listedcontact your local Square D representative for information). Class 8538 and 8539 combination starters are designed to operate at 600 Vac maximum, 50 to 60 Hzand are supplied with melting alloy overload relays as standard.
Fusible Full Voltage Type (Class H Fuse Clips), with Melting Alloy Overload Relays
NEMA 1 General Purpose Enclosure NEMA 4 & 4X Watertight and Dusttight Enclosure Stainless Steel (304) (Sizes 0-5)c Type SBW12a SCW12a SCW13a SDW12a SEW15a SEW12a SFW15a SGW15a SHW13a SBW12a SCW12a SCW13a $ Price 2712.00 2781.00 2811.00 4334.00 7425.00 7739.00 11898.00 28112.00 54077.00 2712.00 2781.00 2811.00 NEMA 4X Watertight, Dusttight and Corrosion Resistant Polyester Enclosure Type SBW22a SCW22a SCW23a SDW22a SEW25a SBW22a SCW22a SCW23a $ Price 3123.00 3195.00 3239.00 4778.00 8166.00 3123.00 3195.00 3239.00 NEMA 12/3Rb Dusttight and Driptight Industrial Use Enclosure With External Reset Type SBA22a SCA22a SCA23a SDA22a SEA25a SEA22a SFA25a SGA25a SHA23a SBA22a SCA22a SCA23a Without External Reset Type SBA12a SCA12a SCA13a SDA12a SEA15a SEA12a SFA15a SGA15a SHA13a SBA12a SCA12a SCA13a 1686.00 1758.00 1785.00 2712.00 4377.00 4692.00 8936.00 20336.00 47219.00 1686.00 1758.00 1785.00
NEMA Size 0 1 2 3 4 5 6 0 1
$ Price
Type 30 30 60 60 100 200 200 400 600 30 30 60 SBG12a SCG12a SCG13a SDG12a SEG15a SEG12a SFG15a SGG15a SHG13a SBG12a SCG12a SCG13a
$ Price 1344.00 1416.00 1443.00 2228.00 3752.00 4064.00 7199.00 16122.00 42305.00 1344.00 1416.00 1443.00
Schneider Electric offers express shipping for factory modified NEMA Combo Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. Ask for Laser Delivery, then select the product and the modifications you need when you place your order. Its as easy as that!
15 2 60 SDG12a 2228.00 SDW12a 4334.00 SDW22a 4778.00 SDA22a SDA12a 2712.00 230 25 100 SEG15a 3752.00 SEW15a 7425.00 SEW25a 8166.00 SEA25a SEA15a 4377.00 (240) 3 30 200 SEG12a 4064.00 SEW12a 7739.00 SEA22a SEA12a 4692.00 50 4 200 SFG15a 7199.00 SFW15a 11898.00 SFA25a SFA15a 8936.00 100 5 400 SGG15a 16122.00 SGW15a 28112.00 SGA25a SGA15a 20336.00 200 6 600 SHG13a 42305.00 SHW13a 54077.00 SHA23a SHA13a 47219.00 5 0 30 SBG13a 1344.00 SBW13a 2712.00 SBW23a 3123.00 SBA23a SBA13a 1686.00 10 1 30 SCG14a 1443.00 SCW14a 2811.00 SCW24a 3239.00 SCA24a SCA14a 1785.00 15 30 SDG16a 2241.00 SDW16a 4350.00 SDW26a 4791.00 SDA26a SDA16a 2712.00 2 25 60 SDG14a 2271.00 SDW14a 4377.00 SDW24a 4820.00 SDA24a SDA14a 2754.00 460 (480) 50 3 100 SEG13a 3824.00 SEW13a 7497.00 SEW23a 8244.00 SEA23a SEA13a 4449.00 100 4 200 SFG13a 7254.00 SFW13a 11955.00 SFA23a SFA13a 8991.00 200 5 400 SGG13a 16122.00 SGW13a 28112.00 SGA23a SGA13a 20336.00 400 6 600 SHG12a 42305.00 SHW12a 54077.00 SHA22a SHA12a 47219.00 5 0 30 SBG13a 1344.00 SBW13a 2712.00 SBW23a 3123.00 SBA23a SBA13a 1686.00 10 1 30 SCG14a 1443.00 SCW14a 2811.00 SCW24a 3239.00 SCA24a SCA14a 1785.00 15 30 SDG16a 2241.00 SDW16a 4350.00 SDW26a 4791.00 SDA26a SDA16a 2712.00 2 25 60 SDG14a 2271.00 SDW14a 4377.00 SDW24a 4820.00 SDA24a SDA14a 2754.00 575 (600) 50 3 100 SEG13a 3824.00 SEW13a 7497.00 SEW23a 8244.00 SEA23a SEA13a 4449.00 100 4 200 SFG13a 7254.00 SFW13a 11955.00 SFA23a SFA13a 8991.00 200 5 400 SGG13a 16122.00 SGW13a 28112.00 SGA23a SGA13a 20336.00 400 6 600 SHG12a 42305.00 SHW12a 54077.00 SHA22a SHA12a 47219.00 a Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown on page 16-31. b NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. c NEMA Size 6 starters are NEMA 4 painted sheet steel enclosures. Note: Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40.
Table 16.80:
Motor Voltage
Fuse Clip Max. Coil NEMA Size Hp Voltage Size Poles (A)
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
$ Price
Type 120 1 2 3 2 3 7-1/2 120 0 1 2 0 1 2 2 30 30 60 30 30 60 SBG62V02 SCG62V02 SDG62V02 SBG62V03 SCG62V03 SDG62V03
240 d e f
240
NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Single phase units require one thermal unit and are not available with Form HxxSolid State Overload Relays. Not included in Laser Delivery program.
16-30
CP1
Discount Schedule
Ratings Motor Voltage (Starter Voltage) Max. Hp Polyphase 3 7-1/2 10 25 40 75 150 3 7-1/2 15 30 50 100 200 5 10 25 50 100 200 400 5 10 25 50 100 200 400
$ Price 1643.00 1715.00 2654.00 4235.00 8693.00 19823.00 45710.00 1643.00 1715.00 2654.00 4235.00 8693.00 19823.00 45710.00 1643.00 1715.00 2654.00 4235.00 8693.00 19823.00 45710.00 1643.00 1715.00 2654.00 4235.00 8693.00 19823.00 45710.00
200 (208)
230 (240)
460 (480)
575 (600)
Table 16.82:
Motor Voltage Coil Voltage
Max. Hp 1 2 3
120
120
0 1 2 0 1 2
240 a b c d e Note:
2 3 240 7-1/2
NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. NEMA Size 6 starters are NEMA 4 painted sheet steel enclosure. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. Single phase units require one thermal unit and are not available with Form HxxSolid State Overload Relays. Not included in Laser Delivery program. Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40.
Table 16.83:
60 Hz 24gf 120g 208 240 277 480 600 Specify f g
CP1
Discount Schedule
16-31
16
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified(i.e., order as 8538SBG11V01S). These voltage codes must include Form S (supplied at no charge). When specifying Form S, please supply motor voltage when ordering (i.e., order as 8538SCG11V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge.
NEMA Size
Max. Hp Polyphase
$ Price
Type
$ Price
Type
$ Price
1709.00 3 0 30 SBG32b 1367.00 SBW32b 2732.00 SBW42b 3140.00 SBA42b SBA32b 1778.00 5 1 30 SCG32b 1436.00 SCW32b 2804.00 SCW42b 3225.00 SCA42b SCA32b 1808.00 7-1/2 1 60 SCG33b 1466.00 SCW33b 2834.00 SCW43b 3252.00 SCA43b SCA33b 2732.00 10 2 60 SDG32b 2249.00 SDW32b 4356.00 SDW42b 4791.00 SDA42b SDA32b 200 SEA35b 4419.00 20 3 100 SEG35b 3794.00 SEW35b 7469.00 SEW45b 8216.00 SEA45b (208) SEA32b 4734.00 25 3 200 SEG32b 4108.00 SEW32b 7781.00 SEA42b SFA35b 8978.00 40 4 200 SFG35b 7241.00 SFW35b 11942.00 SFA45b SGA35b 20435.00 75 5 400 SGG35b 16221.00 SGW35b 28214.00 SGA45b SHA33b 47696.00 150 6 600 SHG33b 42782.00 SHW33b 54176.00 SHA43b 1709.00 3 0 30 SBG32b 1367.00 SBW32b 2732.00 SBW42b 3140.00 SBA42b SBA32b SCA32b 1778.00 5 1 30 SCG32b 1436.00 SCW32b 2804.00 SCW42b 3225.00 SCA42b SCA33b 1808.00 7-1/2 1 60 SCG33b 1466.00 SCW33b 2834.00 SCW43b 3252.00 SCA43b SDA32b 2732.00 15 2 60 SDG32b 2249.00 SDW32b 4356.00 SDW42b 4791.00 SDA42b 230 SEA35b 4419.00 25 3 100 SEG35b 3794.00 SEW35b 7469.00 SEW45b 8216.00 SEA45b (240) SEA32b 4734.00 30 3 200 SEG32b 4108.00 SEW32b 7781.00 SEA42b SFA35b 8978.00 50 4 200 SFG35b 7241.00 SFW35b 11942.00 SFA45b SGA35b 20435.00 100 5 400 SGG35b 16221.00 SGW35b 28214.00 SGA45b SHA33b 47696.00 200 6 600 SHG33b 42782.00 SHW33b 54176.00 SHA43b 5 0 30 SBG33b 1394.00 SBW33b 2762.00 SBW43b 3176.00 SBA43b SBA33b 1736.00 10 1 30 SCG34b 1466.00 SCW34b 2834.00 SCW44b 3252.00 SCA44b SCA34b 1808.00 15 2 30 SDG36b 2262.00 SDW36b 4370.00 SDW46b 4805.00 SDA46b SDA36b 2748.00 460 25 2 60 SDG34b 2291.00 SDW34b 4400.00 SDW44b 4841.00 SDA44b SDA34b 2775.00 (480) 50 3 100 SEG33b 3866.00 SEW33b 7541.00 SEW43b 8294.00 SEA43b SEA33b 4491.00 100 4 200 SFG33b 7298.00 SFW33b 11997.00 SFA43b SFA33b 9035.00 200 5 400 SGG33b 16221.00 SGW33b 28214.00 SGA43b SGA33b 20435.00 400 6 600 SHG32b 42782.00 SHW32b 54176.00 SHA42b SHA32b 47696.00 5 0 30 SBG33b 1394.00 SBW33b 2762.00 SBW43b 3176.00 SBA43b SBA33b 1736.00 10 1 30 SCG34b 1466.00 SCW34b 2834.00 SCW44b 3252.00 SCA44b SCA34b 1808.00 15 2 30 SDG36b 2262.00 SDW36b 4370.00 SDW46b 4805.00 SDA46b SDA36b 2748.00 575 25 2 60 SDG34b 2291.00 SDW34b 4400.00 SDW44b 4841.00 SDA44b SDA34b 2775.00 (600) 50 3 100 SEG33b 3866.00 SEW33b 7541.00 SEW43b 8294.00 SEA43b SEA33b 4491.00 100 4 200 SFG33b 7298.00 SFW33b 11997.00 SFA43b SFA33b 9035.00 200 5 400 SGG33b 16221.00 SGW33b 28214.00 SGA43b SGA33b 20435.00 400 6 600 SHG32b 42782.00 SHW32b 54176.00 SHA42b SHA32b 47696.00 a NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. b Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. c NEMA Size 6 starters are NEMA 4 painted sheet steel enclosures. Note: Some control transformers may require the use of oversized enclosures. Refer to the control transformer selection table on page 16-40.
Table 16.85:
Motor Voltage Coil Voltage
Max. Hp 1 2 3
120
120
0 1 2 0 1 2
30 30 60 30 30 60
1367.00 SBW63V02 1436.00 SCW63V02 2249.00 SDW63V02 1367.00 SBW63V03 1436.00 SCW63V03 2249.00 SDW63V03
240 d e
2 3 240 7-1/2
Single phase units require one thermal unit and are not available with Form HxxSolid State Overload Relays. Not included in Laser Delivery program.
Table 16.86:
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
f
24 V coils are not available on Sizes 47. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8538SBG32V01S). g These voltage codes must include Form S (supplied at no charge). When specifying Form S, please supply motor voltage when ordering (i.e., order as 8538SCG32V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge.
16-32
CP1
Discount Schedule
NEMA Size
$ Price
Type
$ Price 1656.00 1728.00 2528.00 1656.00 1728.00 2528.00 1656.00 1728.00 2528.00 1656.00 1728.00 2528.00 1700.00 1772.00 1800.00 2583.00 1700.00 1772.00 1800.00
Class 8538 Non-Fusible Disconnect Switch TypeNEMA Size 02bg 3 0 N/A SBG11S8c 200 7-1/2 1 N/A SCG11S8c (208) 10 2 N/A SDG11S8c 3 0 N/A 7-1/2 1 N/A 15 2 N/A 5 0 N/A 460 10 1 N/A (480) 25 2 N/A 5 0 N/A 575 10 1 N/A (600) 25 2 N/A Class 8538 Fusible Disconnect Switch TypeNEMA Size 02bg 3 0 30 230 (240) 200 (208) 5 7-1/2 10 3 230 (240) 5 7-1/2 1 1 2 0 1 1 30 60 60 30 30 60 SBG11S8c SCG11S8c SDG11S8c SBG11S8c SCG11S8c SDG11S8c SBG11S8c SCG11S8c SDG11S8c SBG12S8c SCG12S8c SCG13S8c SDG12S8c SBG12S8c SCG12S8c SCG13S8c
15 2 60 SDG12S8c 2583.00 5 0 30 SBG13S8c 1728.00 460 10 1 30 SCG14S8c 1800.00 (480) 15 2 30 SDG16S8c 2597.00 25 2 60 SDG14S8c 2627.00 5 0 30 SBG13S8c 1728.00 575 10 1 30 SCG14S8c 1800.00 (600) 15 2 30 SDG16S8c 2597.00 25 2 60 SDG14S8c 2627.00 Class 8538 Fusible Disconnect Switch Type with Class R Fuse ClipsNEMA Size 02bg 3 0 30 SBG32S8c 1722.00 200 (208) 5 7-1/2 10 3 230 (240) 5 7-1/2 1 1 2 0 1 1 30 60 60 30 30 60 SCG32S8c SCG33S8c SDG32S8c SBG32S8c SCG32S8c SCG33S8c 1794.00 1821.00 2604.00 1722.00 1794.00 1821.00
15 2 60 SDG32S8c 2604.00 5 0 30 SBG33S8c 1751.00 460 10 1 30 SCG34S8c 1821.00 (480) 15 2 30 SDG36S8c 2619.00 25 2 60 SDG34S8c 2646.00 5 0 30 SBG33S8c 1751.00 575 10 1 30 SCG34S8c 1821.00 (600) 15 2 30 SDG36S8c 2619.00 25 2 60 SDG34S8c 2646.00 a NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-serviceTable entrance-rated applications; see page 16-104 for more information. b For NEMA Size 35 starters in oversized NEMA 1, 4 or 12 enclosures, contact factory for pricing and TAG number. c Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown to the right. Note: Some control transformers may require the use of oversized enclosures. Refer to the control transformer selection table on page 16-40.
.
16.89:
NEMA 12/3Ra Dusttight and Driptight Industrial Use Enclosure Fuse Clip Size (A) 30 60 30 60 With External Reset Type 1 1 SCA22S1d SCA23S1d SCA22S1d SCA23S1d Without External Reset Type SCA12S1d SCA13S1d SCA12S1d SCA13S1d 1754.00 1781.00 1754.00 1781.00
NEMA Size
$ Price
CP1
Discount Schedule
16-33
16
460 10 1 30 SCA24S1d SCA14S1d 1781.00 (480) 575 10 1 30 SCA24S1d SCA14S1d 1781.00 (600) d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection Table 16.89.
Table 16.88:
Voltage Code $ Price Adder 60 Hz 50 Hz 24fe V01 No Charge 120f 110 V02 No Charge 208 V08 No Charge 240 220 V03 No Charge 277 V04 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 e 24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8538SBG1158V01S). f These voltage codes must include Form S (supplied at no charge). When specifying Form S, supply motor voltage when ordering (i.e., order as 8538SCG1158V02S). g Not included in Laser Delivery program. Note: For voltage codes used with control transformers, see page 16-110.
Ratings
Circuit Breaker (See NEMA Bolted Page 7-32 Type $ Price Type $ Price Type $ Price SPIN TOP $ Price Type b $ Price Size Type for Breaker Adjustment Range) 1/43 0 HLL36030M71 SBG43d 1814.00 SBW43d 3182.00 \SBW53d 3653.00 1/45 HLL36030M71 SCG44d 1886.00 SCW44d 1 3252.00 SCW54d 3738.00 7-1/2 HLL36050M72 SCG45d SCW45d SCW55d 1-1/25 HLL36030M71 SDG42d 2669.00 SDW42d 2 4778.00 SDW52d 5255.00 7-1/210 HLL36050M72 SDG43d SDW43d SDW53d 1525 3 HLL36100M73 SEG42d 3879.00 SEW42d 7554.00 SEW52d 8310.00 3040 4 JLL36250M75 SFG44d 8508.00 SFW44d 13208.00 SFW54d 14534.00 5060 JLL36250M75 SGG44d 19724.00 SGW44d 31716.00 5 70 DJL36400M36 SGG45d SGW45d 100 DJL36400M36 SHG43d 42825.00 SHW43d 49946.00 6 125150 DJL36600M42 SHG45d SHW45d See Digest 175 Page 16-34Page 16-38 for 1/43 0 HLL36030M71 SBG43d 1814.00 SBW43d 3182.00 SBW53d 3653.00 catalog number contact CIC for pricing. 1/47-1/2 1 HLL36030M71 SCG44d 1886.00 SCW44d 3182.00 SCW54d 3738.00 1-1/27-1/2 HLL36030M71 SDG42d SDW42d SDW52d 10 2 HLL36050M72 SDG43d 2669.00 SDW43d 4778.00 SDW53d 5255.00 15 HLL36100M73 SDG44d SDW44d SDW54d 1530 3 HLL36100M73 SEG42d 3879.00 SEW42d 7554.00 SEW52d 8310.00 4050 4 JLL36250M75 SFG44d 8508.00 SFW44d 13208.00 SFW54d 14534.00 60 JLL36250M75 SGG44d 19724.00 SGW44d 31716.00 5 75100 DJL36400M36 SGG46d SGW45d 125150 DJL36600M42 SHG45d 42825.00 SHW45d 49946.00 6 SHG46d SHW46d 200 PLL34080M68 250300 7 PLL36100M69 SJA43d 57837.00 SJW43d 64958.00 NEMA Size 6 and 7 starters are NEMA 4 painted sheet steel enclosures. NEMAs 7 and 9 bolted are not UL Listed. NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40. Hp Range Polyphase
Table 16.91:
60 Hz 24fe 120f 208 240 277 480 600 Specify e
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8539SBG41V01S). f These voltage codes must include Form S (supplied at no charge). When specifying Form S, please supply motor voltage when ordering (i.e., order as 8539SCG41V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-41 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-34
CP1
Discount Schedule
Ratings
Hp Range Polyphase
NEMA Size
Type
$ Price
Type
$ Price
Type
Bolted Type b
$ Price
$ Price
1/45 0 HLL36030M71 SBG43d 1814. SBW43d 3182. SBW53d 3653. 1/410 1 HLL36030M71 SCG44d 1886. SCW44d 3252. SCW54d 3738. 515 HLL36030M71 SDG42d 2 2669. SDW42d 4778. SDW52d 5255. 2025 HLL36050M72 SDG43d SDW43d SDW53d 2025 HLL36050M72 SEG41d 3 3879. SEW41d 7554. SEW51d 8310. 3050 HLL36100M73 SEG42d SEW42d SEW52d 460 60100 4 JLL36250M75 SFG44d 8508. SFW44d 13208. SFW54d 14534. (480) 125 JLL36250M75 SGG44d 19724. SGW44d 31716. 5 150200 DJL36400M36 SGG45d SGW45d 250350 DJL36600M42 SHG45d 42825. SHW45d 49946. 6 400 PLL34080M68 SHG46d SHW46d 500 PLL36080M68 SJA42d 7 57837. SJW42d 64958. See Digest 175 Page 16-34Page 16-38 600 PLL36100M69 SJA43d SJW43d for catalog number contact CIC for pricing. 1/45 0 HLL36030M71 SBG43d 1814. SBW43d 3182. SBW53d 3653. 1/410 1 HLL36030M71 SCG44d 1886. SCW44d 3252. SCW54d 3738. 520 HLL36030M71 SDG42d 2 2669. SDW42d 4778. SDW52d 5255. 25 HLL36050M72 SDG43d SDW43d SDW53d 2530 HLL36050M72 SEG41d SEW41d SEW51d 3 3879. SEW42d 7554. SEW52d 8310. 4050 HLL36100M73 SEG42d 575 (600) 60100 4 JLL36250M75 SFG44d 8508. SFW44d 13208. SFW54d 14534. 125150 JLL36250M75 SGG44d 19724. SGW44d 31716. 5 200 DJL36400M36 SGG45d SGW45d 250 DJL36400M36 SHG43d 42825. SHW43d 49946. 6 300400 DJL36600M42 SHG45d SHW45d 500600 7 PLL34100M69 SJG41d 57837. SJW41d 64958. a NEMA Size 6 and 7 starters are NEMA 4 painted sheet steel enclosures. b NEMA 7 and 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. Note: Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40.
Table 16.93:
Voltage Code $ Price Adder 60 Hz 50 Hz 24fe V01 No Charge 120f 110 V02 No Charge 208 V08 No Charge 240 220 V03 No Charge 277 V04 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 e 24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8539SBG41V01S). f These voltage codes must include Form S (supplied at no charge). When specifying Form S, please supply motor voltage when ordering (i.e., order as 8539SCG41V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-41 Factory Modifications (Forms). . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . page 16-117
CP1
Discount Schedule
16-35
16
NEMA Size
$ Price
Type $ Price Type $ Price Type Type 1/43 0 HLL36030M71 SBG43S8c 2169.00 SBW43S8c 4248.00 SBA53S8c SBA43S8c 2798.00 1/45 HLL36030M71 SCG44S8c 2241.00 SCW44S8c SCA44S8c 200 1 4320.00 SCA54S8c 2867.00 71/2 HLL36050M72 SCG45S8c SCW45S8c SCA55S8c SCA45S8c (208) 1-1/25 HLL36030M71 SDG42S8c 3024.00 SDW42S8c SDA52S8c SDA42S8c 2 5844.00 SDA53S8c 3794.00 71/210 HLL36050M72 SDG43S8c SDW43S8c SDA43S8c 1/43 0 HLL36030M71 SBG43S8c 2169.00 SBW43S8c 4248.00 SBA53S8c SBA43S8c 2798.00 1/47-1/2 1 HLL36030M71 SCG44S8c 2241.00 SCW44S8c 4320.00 SCA54S8c SCA44S8c 3867.00 230 1-1/27-1/2 HLL36030M71 SDG42S8c SDW42S8c SDA52S8c SDA42S8c (240) 10 2 HLL36050M72 SDG43S8c 3024.00 SDW43S8c 5844.00 SDA53S8c SDA43S8c 3794.00 15 HLL36100M73 SDG44S8c SDW44S8c SDA54S8c SDA44S8c 1/45 0 HLL36030M71 SBG43S8c 2169.00 SBW43S8c 4248.00 SBA53S8c SBA43S8c 2798.00 460 1/410 1 HLL36030M71 SCG44S8c 2241.00 SCW44S8c 4320.00 SCA54S8c SCA44S8c 2867.00 (480) 515 HLL36030M71 SDG42S8c 3024.00 SDW42S8c SDA42S8c 2 5855.00 SDA52S8c 3794.00 2025 HLL36050M72 SDG43S8c SDW43S8c SDA53S8c SDA43S8c 1/45 0 HLL36060M71 SBG43S8c 2169.00 SBW43S8c 4248.00 SBA53S8c SBA43S8c 2798.00 1/410 1 HLL36030M71 SCG44S8c 2241.00 SCW44S8c 4320.00 SCA54S8c SCA44S8c 3867.00 575 (600) 520 HLL36030M71 SDG42S8c 3024.00 SDW42S8c SDA42S8c 2 5844.00 SDA52S8c 3794.00 25 HLL36050M72 SDG43S8c SDW43S8c SDA53S8c SDA43S8c a NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. b For NEMA Size 35 starters in oversized NEMA 1, 4 or 12 enclosures, contact factory for pricing and TAG number. c Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. Note: Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40.
Table 16.95:
60 Hz 24ed 120e 208 240 277 480 600 Specify d e
Voltage
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8539SBG41S8V01S). These voltage codes must include Form S (supplied at no charge). When specifying Form S, please supply motor voltage when ordering (i.e., order as 8539SCG41S8V02S). f Not included in Laser Delivery program. Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-41 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-36
CP1
Discount Schedule
Ratings
Max. Hp Polyphase 2 3 5 7-1/2 10 15 20 25 30 40 50 6075 100125 150 2 3 5 7-1/2 10 15 20 2530 40 50 60 75 100 125 150200 250300
NEMA Size
Circuit Breaker Type Type Ampere Rating 15 20 35 50 60 100 125 150 200 250 250 400 600 800 15 20 35 45 $ Price Type $ Price Type
Bolted Type b
$ Price
0 1 2 3 4 5 6 0 1 2 3 4 5 6 7
HLL36015 HLL36020 HLL36035 HLL36050 HLL36060 HLL36100 HLL36125 HLL36150 JLL36200 JLL36250 JLL36250 DLL36400E20 DLL36600E20 MJL36800 HLL36015 HLL36020 HLL36035 HLL36045
200 (208)
230 (240)
HLL36060 60 SDG1d SDA11d SDA1d 2255. SDW1d 4364. SDW11d 4805. HLL36090 90 SDG7d SDW7d SDW17d SDA17d SDA7d HLL36100 100 SEG3d SEA13d SEA3d 3879. SEW3d 7554. SEW13d 8310. HLL36150 150 SEG5d SEW5d SEW15d SEA15d SEA5d JLL36225 225 SFG1d SFW1d SFW11d SFA11d SFA1d 8508. SFW4d 13208. SFW14d 14534. JLL36250 250 SFG4d SFA14d SFA4d JLL36250 250 SGG6d SGW6d SGA16d SGA6d DLL36400E20 400 SGG4d 19724. SGW4d 31716. SGA14d SGA4d DLL36600E20 600 SGG2d SGW2d SGA12d SGA2d DLL36600E20 600 SHG4d 42825. SHW4d SHA14d SHA4d 49946. MJL36800 800 SHG5d SHW5d SHA15d SHA5d PLL36120 1200 SJG3d 57837. SJW3d 64958. SJA13d a NEMA Size 6 & 7 starters are NEMA 4 painted sheet steel enclosures. b NEMA 7 & 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed below. e Rated 250 Volts Max. Note: Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40.
Table 16.97:
CP1
Discount Schedule
16-37
16
Voltage Code $ Price Adder 60 Hz 50 Hz 24gf V01 No Charge 120g 110 V02 No Charge 208 V08 No Charge 240 220 V03 No Charge 277 V04 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 f 24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8539SBG1V01S). g These voltage codes must include Form S (supplied at no charge). When specifying Form S, please supply motor voltage when ordering (i.e., order as 8539SCG5V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-41 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-109 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . .page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . .page 16-117
Ratings
Max. Hp Polyphase 5 7-1/2 10 15 20 25 30 40 50 60 75 100 125150 200 250 300400 500600 5 7-1/2 10 15 20 25 30 40 50 6075 100 125150 200 250350 400 500600
NEMA Size 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
Circuit Breaker Type Type HLL36015 HLL36025 HLL36030 HLL36045 HLL36060 HLL36070 HLL36080 HLL36100 HLL36150 JLL36160 JLL36200 JLL36250 DLL36400E20 DLL36600E20 DLL36600E20 MJL36800 PLL36120 HLL36015 HLL36020 HLL36025 HLL36035 HLL36045 HLL36060 HLL36070 HLL36090 HLL36100 JLL36150 JLL36250 JLL36250 DLL36400E20 DLL36600E20 MJL36800 PLL36120 Ampere Rating 15 25 30 45 60 70 80 100 150 150 200 250 400 600 600 800 1200 15 20 25 35 45 60 70 90 100 150 250 250 400 600 800 1200 $ Price Type $ Price Type
Bolted Type b
$ Price
$ Price
460 (480)
575 (600)
Table 16.99:
NEMA Size
Poles
Ampere Rating
120 240
1 2 3 2 3 7.5
120 240
0 1 2 0 1 2
Type $ Price Type $ Price Type $ Price Type Type HLL26030 30 SBG72V02 1400.00 SBW72V02 2768.00 SBW75V02 3182.00 SBA75V02 SBA72V02 1742.00 2 HLL26050 50 SCG72V02 1474.00 SCW72V02 2840.00 SCW75V02 3267.00 SCA75V02 SCA72V02 1814.00 HLL26080 80 SDG71V02 2255.00 SDW71V02 4364.00 SDW74V02 4805.00 SDA74V02 SDA71V02 2739.00 1742.00 HLL26025 25 SBG71V03 1400.00 SBW71V03 2768.00 SBW74V03 3182.00 SBA74V03 SBA71V03 1814.00 2 HLL26035 35 SCG71V03 1474.00 SCW71V03 2840.00 SCW74V03 3267.00 SCA74V03 SCA71V03 SDA71V03 2739.00 HLL26080 80 SDG71V03 2255.00 SDW71V03 4364.00 SDW74V03 4805.00 SDA74V03 a NEMA Size 6 and 7 starters are NEMA 4 painted sheet steel enclosures. b NEMA 7 and 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed on page 16-37. e Single phase units require one thermal unit and are not available with Form HxxSolid State Overload Relays. f Not included in Laser Delivery program. Note: Some control transformers may require the use of oversized enclosures. Refer to control transformer selection table on page 16-40.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-38
CP1
Discount Schedule
Application Data
Table 16.100: Class 8539UL Listed Short Circuit Ratings
Motor Circuit Protector Type NEMA Size Amps Interrupting Capability Rating (AIC) 0, 1 480 Standarda 100,000 0, 1 481600 Standarda 35,000 2, 3, 4 480 Standarda 100,000 2, 3, 4 481600 Standarda 50,000 5, 6, 7 600 Standarda 22,000 Standard enclosure includes: NEMAs 1, 4 & 4X stainless and 12/3R. Voltage Enclosure
Note: The combination starter selection tables on pages 16-3516-36 are suitable for motors with Locked-Rotor Current letters per NEC Table 430-7(b) as listed in Table 16.104. For other motors a special thermal magnetic circuit breaker with adjustable magnetic trip settings for the specific motor is required. When ordering for these special applications, specify the motor horsepower, voltage, frequency, full load current and code letter (or locked rotor current) to assure proper protection.
2 2 2 2
16-39
16
selection. For electrical ratings of disconnect and circuit breaker interlocks, see Table 16.107 below. An electrical interlock may also be factory installed in either a disconnect switch or circuit breaker combination starter. Specify Form Y74 for single pole, or Form Y75 for two pole interlocks. For pricing see factory modifications (Forms).
SPDT (Y74) Class 9999 Type R6 R43 R45 R8 R41 R39 R35 R26 TC11 TC10 TC10 TC11 TC10 TC10 TC10 $ Price 116.00 116.00 107.00 131.00 131.00 135.00 435.00 131.00 120.00 120.00 120.00 120.00 120.00 120.00 120.00
DPDT (Y75) Class 9999 Type R7 R44 R46 R9 R42 R40 R36 R27 TC21 TC20 TC20 TC21 TC20 TC20 TC20 $ Price 221.00 221.00 207.00 243.00 243.00 243.00 521.00 243.00 239.00 239.00 239.00 239.00 239.00 239.00 239.00
a b
SBb, SCb, SDb (Series B) SD (Series C) SB, SC (Series C) 8538 SE, SF (Series A) & SE (Series B & C) 8738 SF (Series B & C) SG 8539, 8739 SB, SC, SD, SE, SF, SGa 8538 SBA, SCA, SBG, SCG (Series D) 8538 SBAS8, SCAS8, SBGS8, SCGS8 (Series D) 8738 SBAS8, SCAS8, SBGS8, SCGS8 (Series E) 8738 SBA, SCA, SBG, SCG (Series E) 8538 SDA, SDAb, SDG, SDGb (Series D) 8738 SDA, SDG (Series E) 8538, 8738 SEA, SEG (Series D) No interlocks available for the GJL circuit breaker. The internally mounted auxiliary switch (catalog number AAC) must be used. Class 8538 type numbers ending in suffix S8.
These 100 VA kits are designed specifically to allow for field modification of NEMA Size 0, 1 and 2 combination starters that require a control power transformer. The kit includes a 9070TF100 fused transformer on a special mounting plate for ease of placement and installation on the combo starter back pan. A wire harness (with wiring diagrams) is included to complete the kit. Table 16.108: Control Transformer Field Modification Kits
Catalog Number 9999CPT1D1 9999CPT1D3 Primary Voltage 240 x 480 208 Secondary Voltage 120 120 $ Price 447.00 447.00
NEMA Size
Starter Type
Class 9070 Class 9070 Class 9070 Class 9070 Type Type Type Type 0&1 SB & SC T100 T150 T200 T300c 2 SD T100 T150 T300d T300d 3 SE T150 T150 T300 T500 4 SF T300 T300 T500 T500 T50 and T100 and T150 and T300 and 5 SG 8501XO20 8501XO20 8501XO20 8501XO20 EO3S2 is EO3S2 and EO3S2 and EO3S2 and 6 SH standard T50 T100 T200 EO19S2 is EO19S2 and EO19S2 and EO3S2 and 7 SJ standard T50 T100 T200 c Requires oversized enclosure. (Size 2 reversing enclosure.) d Available in standard enclosure with Mag-Gard circuit breaker and non-fusible disconnect switch. Requires oversized enclosure with thermal-magnetic circuit breakers and fusible disconnect switches. (Size 2 reversing enclosure.) e Complete the contactor or starter Class and Type with Voltage Code, see page 16-110.
Internal Auxiliary SwitchCircuit breakers can be supplied with a factory installed auxiliary switch for remote indication of an open and/or tripped or a closed breaker. One (specify Form Y741) or two (specify Form Y751) auxiliary switches can be supplied. The switches are supplied with normally open and normally closed circuits with a common connection. Contacts must be used on the same polarity and are rated 15 Amps at 240 Vac. The auxiliary switches are located internally and are furnished with 19-20 inch long leads. Alarm SwitchThe alarm switch only operates when the breaker is tripped. It is used to actuate bell alarms and warning lights. The alarm switch is factory installed only (specify Form Y742) and consists of a single pole single throw switch which is normally open except when the breaker is tripped. The contacts are rated 4 Amps at 240 Vac. This switch is located in the breaker and is supplied with 19-20 inch long leads. Transformer SelectionSpace and drilling are provided in all disconnect switch and circuit breaker combination starters in NEMA 1, 4 & 4X stainless and polyester, 12 and 7 & 9 bolted enclosures for the field addition (or factory installation) of a Class 9070 control circuit transformer and Class 9999 Type SFR4 fuse holder. This kit can be either panel mounted or side mounted on the Type S starter. For standard control transformer selection in combination starters, see Table 16.109. Consult field office for transformer additions to NEMA 7 & 9 SPIN TOP enclosures. For secondary fuse holder order 9080PF1. Fuse Block Mounting BracketsThe standard capacity transformer, Class 9070 Type T100, for the Size 0 and 1 starters mounts to the right of the magnetic starter. StandardsMost combination starters and forms are UL Listed in file E152395, Category NKJH, and CSA File CR 584.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-40
CP1
Discount Schedule
Approximate Dimensions
Table 16.110: NEMA 1 EnclosureFigure 1
NEMA Size Class 8538 01 8539 2 8538 & 8539 Type SBG SCG SBG SCG SDG Dimensions in Inchesa A B C D E F G H I J K L M N O P Top & Bottom W 1/23/4 1/23/4 11-1/4 X 1/23/4 1/23/4 1/23/4 Sides Y 1/2 1/2 1/2 Wt. (lbs.) 38 38 54
6-3/8 20-1/2 14-21/32 1-13/16 1-11/16 3 2-5/16 1-1/16 6-3/8 20-1/2 14-21/32 1-13/16 1-11/16 3 2-5/16 1-1/16 7-3/8 24 16-29/32 2-1/8 2 4 2-5/16 1-1/16
Dimensions also for Form F4T (standard control transformer). Form F4T11 (100 VA extra capacity) and Form F4T12 (200 VA extra capacity) could require the use of an oversized enclosure. Refer to control transformer selection table on page 16-40. b Class 8538 Size 3 devices with 200 A fuse clips use dimensions for Class 8538 Size 4. Handle Swing c Left side only. Handle Swing A L C d DimensionsM include space for control circuit transformers. Handle Swing A D B Handle Swing D E N A A F e Size 6 enclosures are floor mounting. C K L B D H D E E F O H Note: Illustrations may not represent the actual enclosure; they are intended for dimensional information only. H Y f (4) .31 in (8 mm) dia. mtg. holesO sizes 0, 1, and 2, (4) .44 in (11 mm) dia. mtg. holes for sizes 3 and 4, (4) .56 in (14 mm) dia. mtg. holes located on external flanges for size 5. for
P E B G B G C G C Y
f
Y Cover Open 90 F W X W G J H I K M N F W X W J I I K
f f
Cover Open 90 Cover Open 90 J L W X J
f
Cover Open 90
16-41
16
Approximate Dimensions
Class 8538, 8539 / Refer to Catalog 8538CT9701
www.schneider-electric.us
A E
Type A B C E 0, 1 8538 SBW SCW 13.72 11.4 26.94 6.25 0, 1 8539 SDW 0, 1, & 2 8738, 8739 SBW SCW 25.25 11.4 27.00 17.88 2 8538, 8539 SDW 8538, 8738 SEW 34 26.31 11.4 33.50 18.50 8539, 8739 SFW b a Dimensions also for Form F4T (standard control transformer) and Form F4T10 (50 VA additional capacity). Other control transformers may require the use of oversized enclosures. refer to the control transformer selection table on page 16-40. b 8539 Size 4 only.
NEMA Size
Class
25.75 32.25
A D
Handle Swing L
Figure 2 Class 8538 and 8539 in Oversize Enclosures NEMA 1, 4 & 4X Stainless and 12
N M
500
B F
Note: Bolted enclosure comes equipped with 3 closing plates in the door.
15-1/4 8
.19 5
(2) "Z" Pipe Tap Top and Bottom 1/2" NPT for Breather and Drain
D
Information on Hubs
Hubs are supplied with each NEMA Type 4X combination starter as shown in the table below. Note that hubs are only installed in stainless steel enclosures; they are not installed in polyester enclosures. Table 16.118: Hub Sizes
NEMA Size 0&1 2 3&4 Quantity 1 2 1 2 1 2 Hub Size 0.75" 1.00" 0.75" 1.50" 0.75" 2.50"
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
TOP VIEW
E Q A C K B J D H M
Note: Illustrations may not represent the actual enclosure; they are intended for dimensional information only.
G F
Circuit Breaker Operating Handle Space Required to Remove Combination Form Only (Add 1.00 In. to Overall Width) Bottom Cover
16-42
Class 8702 Type S reversing magnetic contactors are used for starting, stopping, and reversing AC motors where overload protection is separately provided. Class 8702 reversing contactors consist of two Class 8502 contactors mechanically and electrically interlocked. Open type devices, Sizes 05, are available in either horizontal or vertical arrangements. Sizes 00, 6, and 7 are available as horizontal only. Enclosed devices, Size 007, use horizontally arranged components. Type S reversing contactors are designed for operation at 600 Vac, 5060 Hz. Table 16.120:
Continuous Current Ratings NEMA Type 1 General Purpose Enclosure NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Sizes 05)a Type $ Price NEMA 7 & 9 c Hazardous Locations, Div. 1 & 2 Class I, Groups C & D Class II, Groups E, F & G Bolted Type $ Price Aluminum Use Size 0 SPIN TOP Type NEMA 12/3Rd Dusttight & Driptight Industrial Use Enclosure
NEMA Size
Open Type Motor Voltage Max. Hp Vertical Horizontal $ Price Type Type 200 230 460 575 200 230 460 575 200 230 460 575 1-1/2 1-1/2 2 2 3 3 5 5
Type
$ Price
$ Price
Type
$ Price
00
SAO4b
855.00 SAG4b
917.00
Use Size 0
Use Size 0
Use Size 0
18
SBO12b SBO4b
27
SCO8b
200 10 230 15 SDO1b SDO2b 2222.00 SDG2b 2456.00 SDW11b 3936.00 SDT43b 6507.00 SDR3b 8139.00 SDA1b 2883.00 460 25 575 25 200 25 30 3 90 230 SEO1b SEO2b 3689.00 SEG2b 4094.00 SEW11b 6287.00 SEA1b 5034.00 460 50 575 50 200 40 50 4 135 230 SFO1b SFO3b 9201.00 SFG3b 9945.00 SFW11b 13820.00 SFA1b 11399.00 460 100 575 100 200 75 100 5 270 230 SGO1b SGO3b 16592.00 SGG3b 20885.00 SGW11b24017.00 SGA1b 24017.00 460 200 575 200 200 150 200 6 540 230 SHO1b 41489.00 SHG1b 48614.00 SHW1b 55736.00 SHA1b 52461.00 460 400 575 400 200 300 7 810 230 SJO1b 59372.00 SJG1b 66816.00 SJW1b 73619.00 SJA1b 70343.00 460 600 575 600 a NEMA 4 and 4X stainless steel enclosures (sizes 05) have a brushed finish. Sizes 6 and 7 are painted sheet steel and are rated NEMA 4 only. b Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table below. c NEMA 7 and 9 bolted are not UL listed. d NEMA 12 enclosure may be field modified for outdoor non-corrosive and non-service-entrance-rated application; see page 16-104 for more information. 2 45
CP1
Discount Schedule
16-43
16
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8702SAO4V01S). f These voltage codes must include Form S (supplied at no charge) (i.e., order as 8702SAO4V02S) Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-47 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-109 Separate Enclosures (Class 9991). . . . . . . . . . . . . . . . . . . . . . . . page16-102 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . .page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . .page 16-117
Max. Hp
NEMA 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure Type $ Price
NEMA 7 & 9 b Hazardous Locations, Div. 1 & 2 Class I, Groups C & D Class II, Groups E, F & G Bolted Type
$ Price SPIN TOP $ Price Type
NEMA 12/3Rc Dusttight & Driptight Industrial Use Enclosure Type $ Price
2-Pole Single Phase 00 0 1 9 18 27 115 230 115 230 115 230 115 230 115 230 115 230 115 230 115 230 115 230 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 1/3 1 1 2 2 3 1/3 1 1/3 1 1 2 1 2 2 3 2 3 SBO9a SCO1a SAO1a SBO1a SCO2a 827. 998. 1139. SAG1a SBG1a SCG2a 887. 1061. 1229. Use Size 0 SBW11a SCW11a 1715. 2142. Use Size 0 SBT46a SCT46a 3686. 3873. Use Size 0 SBR6a SCR6a 4613. 4841. Use Size 0 SBA1a SCA1a 1314. 1485.
3-Pole Single Phase 4-Wire Rep.-Ind. 4-Wire Split Ph. 4-Wire Rep.-Ind. 4-Wire Split Ph. 4-Wire Rep.Ind. 4-Wire Split Ph. SBO10a SBO11a SCO3a SCO5a SAO2a SAO3a SBO2a SBO3a SCO4a SCO6a 855. 855. 1026. 1026. 1169. 1169. SAG2a SAG3a SBG2a SBG3a SCG4a SCG6a 917. 917. 1088. 1088. 1259. 1259. Use Size 0 Use Size 0 SBW12a SBW13a SCW12a SCW13a 1742. 1742. 2169. 2169. Use Size 0 Use Size 0 SBT47a SBT48a SCT47a SCT48a 3716. 3716. 3900. 3900. Use Size 0 Use Size 0 SBR7a SBR8a SCR7a SCR8a 4649. 4649. 3227. 3227. Use Size 0 Use Size 0 SBA2a SBA3a SCA2a SCA3a 1344. 1344. 1515. 1515.
00
18
27
4-Pole Polyphase 0 18 3 3 SBO13a SBO5a 1310. SBG5a 1368. SBW15a 2028. SBR10a 5040. SBA5a 1629. 5 5 Consult 7-1/2 Square D/ 7-1/2 Electric SCR10a SCO9a SCO10a 1497. SCG10a 1557. SCW15a 2469. Schneider at 5297. SCA5a 1814. 10 CIC 10 1-888-SquareD (1-888-778-2733) 10 15 2 Phase SDO4a 2820. SDG4a 3054. SDW12a 4620. SDR4a 9071. SDA2a 3528. 25 4-Wire 25 25 30 SEO4a 4671. SEG4a 5103. SEW12a 7238. SEA2a 6017. 50 50 40 50 SFO4a 11879. SFG4a 12653. SFW12a 16556. SFA2a 14129. 100 100 a Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table on page 16-43. b NEMA 7 and 9 bolted are not UL listed. c NEMA 12 enclosure may be field modified for outdoor non-corrosive and non-service-entrance-rated application; see page 16-104 for more information.
27
45
90
135
Table 16.123: Auxiliary UnitsClass 8702, 8736 and 8810 The table below shows the maximum number of auxiliary units (in addition to the holding circuit and interlocking contacts) that can be added to either the forward or reverse contactor or starter.
NEMA Size (Type) 00 (SA) 0, 1 and 2 (SB, SC and SD) 3, 4, 5, 6, and 7 (SE, SF, SG, SH, and SJ) d No. of Poles of Basic Contactor 2 or 3 2 or 3 4 Any Maximum number of auxiliary units on each contactor, forward or reverse. (In addition to internal holding circuit and interlocking contacts.) 2 single circuit auxiliary contacts (N.O. or N.C.) 4 single circuit auxiliary contacts (N.O. or N.C.)d 2 single circuit auxiliary contacts (N.O. or N.C.) 2 single circuit auxiliary contacts (N.O. or N.C.)
When adding 4 external auxiliary contacts to one Size 0 or 1 contactor, remove one of the return springs.
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-47 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Separate Enclosures (Class 9991) . . . . . . . . . . . . . . . . . . . . . . . page 16-102 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-44
CP1
Discount Schedule
Class 8736 Type S reversing magnetic starters are used for full-voltage starting, stopping, and reversing AC squirrel cage motors. Class 8736 starters consist of one Class 8502 contactor and one Class 8536 starter mechanically and electrically interlocked. Open type devices, Sizes 05, are available in either horizontal or vertical arrangements. Sizes 00, 6, and 7 are available as horizontal only. Enclosed devices use horizontally arranged components. Type S starters are designed for operation at 600 Vac, 5060 Hz.
Overload Relays
Class 8736 Type S Size 006 reversing starters are provided with melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip Sizes 006, as are bimetallic overload relays. Ambient compensated and non-compensated versions are supplied with manual or automatic reset, trip current adjustment, and an alarm contact on Sizes 02. Quick trip is available on Sizes 004, and slow trip on Sizes 003. Single phase starters use one thermal unit; three phase starters use three thermal units. See page 16-125 for selection information.
These ambient insensitive overload relays are available on three phase sizes 00 through 6 and standard on size 7. They provide phase loss, phase unbalance protection. To order, add Form H10 (for Class 10), H20 (for Class 20), or H30 (for selectable trip class protection). For more information about MOTOR LOGIC overload relays, see page 16-91. Table 16.124:
Continuous Current Ratings NEMA Type 4 & 4X NEMA 1 Watertight, Dusttight General Purpose Brushed Enclosure Stainless Steel Enclosure (Sizes 05)a Type $ Price Type NEMA 7 & 9 c Hazardous Locations Class I, Groups C & D Class II, Groups E, F & G SPINTOP $ Price Type Use Size 0 NEMA Type 12/3Rd Dusttight & Driptight Industrial Use Enclosure Type $ Price
NEMA Size
Open Type Motor Voltage Max. Hp Vertical Horizontal $ Price Type Type 200 230 460 575 200 230 460 575 200 230 460 575 1-1/2 1-1/2 2 2 3 3 5 5 7-1/2 7-1/2 10 10 SBO10b
00
SAO16b
926. SAG16b
989.
Use Size 0
Use Size 0
Use Size 0
18
SBO4b
1097. SBG4b
1160.
SBW14b
1814. SBT49b
3794. SBR9b
4742. SBA4b
1416.
27
SCO7b
SCO8b
1241. SCG8b
1331. SCW14b
2241. SCT49b
3978. SCR9b
4976. SCA4b
1587.
7 a b c d
200 10 230 15 SDO1b SDO2b 2349. SDG2b 2583. SDW11b 4064. SDT43b 6642. SDR3b 8064. SDA1b 3011. 460 25 575 25 200 25 230 30 SEO1b SEO2b 3902. SEG2b 4307. SEW11b 6501. SEA1b 5247. 90 460 50 575 50 200 40 230 50 135 SFO1b SFO3b 9530. SFG3b 10274. SFW11b 14148. SFA1b 11727. 460 100 575 100 200 75 230 100 270 SGO1b SGO3b 18309. SGG3b 22602. SGW11b 25734. SGA1b 25734. 460 200 575 200 200 150 230 200 540 SHO1b 43205. SHG1b 50331. SHW1b 57452. SHA1b 54176. 460 400 575 400 200 230 300 75497. SJA1b 72221. 810 SJO1b 61250. SJG1b 68736. SJW1b 460 600 575 600 NEMA 4 and 4X stainless steel enclosures (sizes 05) have a brushed finish. Sizes 6 and 7 are painted sheet steel and are rated NEMA 4 only. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown on page 16-46. NEMA 7 and 9 bolted are not UL listed. NEMA 12 enclosure may be field modified for outdoor non-corrosive and non-service-entrance-rated application; see page 16-104 for more information. 45
CP1
Discount Schedule
16-45
16
Table 16.125: 600 Vac Maximum5060 Hz Note that prices shown do not include thermal units. Standard trip thermal units are $21.50 each. See page 16-125 for selection information.
NEMA Continuous Motor Current Size Voltage Ratings Open Type NEMA 1 General Purpose Enclosure Type $ Price NEMA 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure Type $ Price NEMA 7 & 9 b Hazardous Locations Class I, Groups C & D Class II, Groups E, F & G Bolted Type
$ Price SPIN TOP $ Price Type
Max. Hp
NEMA 12/3Rc Dusttight & Driptight Industrial Use Enclosure Type $ Price
2-Pole Single Phase1 Thermal Unit Required 115 1/3 00 9 SAO13a 863. SAG13a 923. Use Size 0 Use Size 0 Use Size 0 Use Size 0 230 1 Single 115 1 0 18 Phase SBO7a SBO1a 1034. SBG1a 1094. SBW11a 1751. SBT46a 3722. SBR6a 4656. SBA1a 1350. 230 2 3-Wire 115 2 1 27 SCO1a SCO2a 1175. SCG2a 1265. SCW11a 2177. SCT46a 3909. SCR6a 4883. SCA1a 1521. 230 3 3-Pole Single Phase1 Thermal Unit Required 115 1/3 4-Wire SAO14a 891. SAG14a 953. Use Size 0 Use Size 0 Use Size 0 Use Size 0 230 1 Rep.-Ind. 00 9 115 1/3 4-Wire SAO15a 594. SAG15a 635. Use Size 0 Use Size 0 Use Size 0 Use Size 0 230 1 Split Ph. 115 1 4-Wire SBO8a SBO2a 1062. SBG2a 1124. SBW12a 1778. SBT47a 3752. SBR7a 4692. SBA2a 1380. 230 2 Rep.-Ind. 0 18 115 1 4-Wire SBO9a SBO3a 1062. SBG3a 1124. SBW13a 1778. SBT48a 3752. SBR8a 4692. SBA3a 1380. 230 2 Split Ph. 115 2 4-Wire SCO3a SCO4a 1205. SCG4a 1295. SCW12a 2205. SCT47a 3942. SCR7a 4932. SCA2a 1551. 230 3 Rep.Ind. 1 27 115 2 4-Wire 3942. SCR8a 4932. SCA3a 1551. SCO5a SCO6a 1205. SCG6a 1295. SCW13a 2205. SCT48a 230 3 Split Ph. 4-Pole Polyphase2 Thermal Units Required 200 3 Contact your nearest 230 3 0 18 SBO11a SBO5a 1382. SBG5a 1443. SBW15a 2100. Square D/Schneider SBR10a 5133. SBA5a 1670. 460 5 Electric sales office. 575 5 200 7-1/2 Contact your nearest 230 7-1/2 1 27 SCO9a SCO10a 1566. SCG10a 1629. SCW15a 2541. Square D/Schneider SCR10a 5396. SCA5a 1886. 460 10 Electric sales office. 575 10 200 10 Contact your nearest 230 15 2 Phase 2 45 SDO4a 2948. SDG4a 3182. SDW12a 4748. Square D/Schneider SDR4a 9248. SDA2a 3609. 460 25 4-Wire Electric sales office. 575 25 200 25 230 30 3 90 SEO4a 4886. SEG4a 5318. SEW12a 7482. SEA2a 6228. 460 50 575 50 200 40 230 50 4 135 SFO4a 12207. SFG4a 12981. SFW12a 16883. SFA2a 14462. 460 100 575 100 a Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. b NEMA 7 and 9 bolted are not UL listed. c NEMA 12 enclosure may be field modified for outdoor non-corrosive and non-service-entrance-rated application; see page 16-104 for more information.
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8736SCO1U01S). e These voltage codes must include Form S (supplied at no charge) (i.e., order as 8736SBO7V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-47 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Separate Enclosures (Class 9991) . . . . . . . . . . . . . . . . . . . . . . . page 16-102 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . .page16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-46
CP1
Discount Schedule
Approximate Dimensions
Table 16.127: Open Type2 or 3-Pole Only
Class NEMA Size 00 0, 1 2 3 8702 4 5 6 7 00 0, 1 2 3 8736 4 5 6 7 a SFO SGO SHO SJO Horizontal Vertical Horizontal Vertical Horizontal Horizontal 2 2a 2 2a 2 1 14-1/4 14-19/32 7-31/32 26-13/16 19-5/16 20-29/32 10-3/4 39-5/32 22-3/8 24-1/4 28-3/64 37-1/4 7 7 9-3/8 9-3/8 9-33/64 13-13/16 13-1/4 7 18 9-1/2 18 19-3/4 1/2 31/64 21/32 21/32 44/64 1-33/64 1-27/32 1-27/32 1-9/32 1-9/32 3-53/64 12-1/4 24-1/2 19 371/4 21-3/16 30 12-1/4 19 37-1/4 3-1/32 13-1/4 4-3/64 18 9-1/2 18 6-1/4 6-1/4 6-5/8 6-5/8 49/64 1/2 31/64 5/8 5/8 13-1/4 7 18 9-1/2 48 48 115 115 200 315 SFO SGO SHO SJO SAO SBO, SCO SDO SEO Horizontal Vertical Horizontal Vertical Horizontal Horizontal Horizontal Horizontal Vertical Horizontal Vertical Horizontal Vertical 1 1a 1 1a 1 1 2 2 2a 2 2a 2 2a 14-1/4 11-11/16 7-31/32 23-29/32 19-5/16 16-3/16 10-3/4 34-13/32 22-3/8 24-1/4 7-1/8 28-3/64 37-1/4 6-29/32 7 7 9-3/8 9-3/8 9-33/64 13-13/16 5-5/16 5-5/16 5-5/16 6-1/32 6-1/32 7 7 13-1/4 7 18 9-1/2 18 19-3/4 5-1/32 6-1/4 11-3/4 6-1/4 1/2 31/64 21/32 5/8 40/64 1-33/64 7/32 1/4 31/64 31/64 3-13/32 3-13/32 4-1/2 1/2 1-13/16 1-1/32 1-1/4 3-53/64 15/32 15/32 39/64 3/8 25/32 31/64 1-1/64 8 20-1/4 14 32 21-3/16 30 4-11/32 1-27/32 1-3/16 1-5/32 1-5/32 3-1/32 6-7/32 13-1/4 7 18 9-1/2 18 4-17/32 4-17/32 2-33/64 5 3-1/8 11-3/4 6-1/4 1/2 31/64 21/32 5/8 49/64 5-1/16 5-1/16 5-1/16 5-5/32 5-5/32 6-1/4 6-1/4 21/32 21/32 7/32 1-1/2 1/4 31/64 31/64 5-1/32 6 11-3/4 6-1/4 45 45 98 98 195 310 13 13 13 18 18 38 38 Type Mounting Figure Number 1 1 1a 1 1a 1 1a DimensionsInches A 7-1/8 7-1/8 5-15/32 9 6-3/4 12-23/32 7-13/64 B 5 5 9-7/32 6-7/8 11-3/8 7-31/32 19 C 5-5/16 5-5/16 5-5/16 6-1/32 6-1/32 7 7 D 5-1/2 6-1/4 11-3/4 6-1/4 E 7/32 1/4 31/64 31/64 F 3-13/32 3-13/32 4-1/2 G 15/32 15/32 39/64 3/8 1/2 31/64 1-1/64 H 4-11/32 4-11/32 8 5-5/8 10-3/8 7 17 I 3/16 3/16 39/64 1/4 1/2 31/64 63/64 J 5-1/2 5-1/2 5-1/32 6 1/4 11-3/4 6-1/4 K 29/32 29/32 7/32 1-1/2 1/4 31/64 31/64 L M Weight (lbs.) 12 12 12 16 16 35 35
4-11/32 6-7/32 8 10-45/64 5-5/8 10-3/8 10-3/4 20-3/4 7-1/2 12-31/32 10-3/4
Vertical type design differs from that shown on the corresponding NEMA size horizontal type figure, but dimensions listed apply to that figure.
A D F E C G
A D F
E G C
H H B I
RESET
J J K I M
Figure 2 (Class 8736 Open Type) NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
A
8702 16 24 95 298 400 8736
17 25 98
18-5/32 29-5/32
B
35-7/32 46-7/32 12-13/16 12-15/16 36-7/32 62-7/32 34-1/2 93 19-15/32 23-1/2 315 405
RESET
Floor Mounting.
Figure 3NEMA 1
2009 Schneider Electric All Rights Reserved
16-47
16
Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices. 3-Pole only.
H D C
Approximate Dimensions
Table 16.129: NEMA 4 & 4XStainless Steelc
Hub Dia. NEMA Size Class Number A 0a 1a 2a 3b 4b 5 8736 6 7 a b c 35-7/32 12-15/16 49-7/32 70-1/8 Floor Mounting 8702 & 8736 34-1/2 23-1/2 101
H K
DimensionsInches B C D E F G H 3-7/8 3-7/8 I 18-13/32 20-7/8 J 1-21/32 1-23/32 2-9/16 2-9/16 2-31/32 2-31/32 K L W Bot. Only 3/4 3/4 3/4 3/4 3/4 3/4
Weight (lbs.) X Top & 8702 8736 Bot. 1 1-1/2 2-1/2 2-1/2 3-1/2 3-1/2 25 33 96 300 500 26 35 99 317 505
I
A E
F C
8702 & 8736 12-5/8 8702 & 8736 14-7/8 8702 8736 8702 18-5/32 18-5/32 35-7/32
7-13/16 14-11/16 8-1/4 8-3/4 9-9/16 12-1/8 15-3/4 32-7/32 32-7/32 49-7/32
2-9/16 7-1/2 13-1/2 19/32 2-9/16 9-3/4 3-5/64 3-5/64 4-7/64 4-7/64 12 12 27 27 15 30-1/2 30-1/2 48 48 3/8 7/8 7/8 5/8 5/8
2-5/16 5/16 2-5/8 5/16 3-3/16 7/16 3-3/16 7/16 3-1/2 9/16 3-1/2 9/16
W X J
Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices. 3-Pole only. Size 6 & 7 are sheet steel enclosures and are rated NEMA 4 only.
Table 16.130: NEMA 7 and 9 Bolted Enclosure See page 16-26 for drawing of enclosure.
NEMA Size 02 34 d Type SBT SCT SDT SET SFT DimensionsInchesd G 14-1/4 24-1/2 H 27-5/8 45-5/8 J 9-1/2 13-3/4 K 12-1/4 22-1/2 L 19-1/4 27-1/2 N 9-5/8 13-3/4 P 11-1/2 15-3/8 Q, R 2-3/8 3-7/16 S, T, U, V 3-1/8 4 Wt. (lbs.) 115 180
Table 16.131: NEMA 7 & 9 SPIN TOP Enclosure See page 16-25 for drawing of enclosure.
NEMA Size 0-1 2 3 e f Type SBR SCR SER Without control transformer. With control transformer (Form F4T). DimensionsInches A 12 Be Bf Ce Cf D Ee Ef F Ge Gf He 3 8 Hf 9 4-1/2 Je 24 25 Jf 24 30 K 8-1/2 12 L 2-1/16 2-5/8 M 9-3/8 11 N 5-1/4 5-1/2 P 1-1/2 2-1/2 R 3/8 3/8 Wt. (lbs.) 70 100
20-1/4 12-1/8
A E
3-21/32 18-1/8 3-21/32 21-1/4 3-11/16 26-23/32 4-1/2 26-23/32 5-5/16 45-7/8
Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices. 3-Pole only.
16
H
NEMA 12
16-48
Class 8702 Type W Reversing Vacuum Contactors are used to switch capacitors, transformers and electric motors where overload protection is separately provided. Type W reversing vacuum contactors are designed for operation at 600 Volts, 50/60 Hz. Auxiliary ContactsAn auxiliary contact block, Class 9999 Type WX11, with one normally open contact and one normally closed contact, is used with Size 4, 5 and 6 vacuum contactors. Additional auxiliary contact units may be added to the Size 4 and 5 reversing contactors in the field. A maximum of 2 units may be added to the Size 4; a maximum of 1 unit may be added to the Size 5. Termination MeansThe Size 4 reversing vacuum contactor is supplied with line and load side lugs. The Size 5 and 6 reversing vacuum contactors are supplied without line and load side lugs. Table 16.133: Class 8702 Full Voltage Reversing Vacuum Contactors (Horizontal Only) 3-Pole Polyphase600 Vac Maximum5060 Hz
NEMA Size Enclosed Ampere Rating Motor Voltage 200 230 380 460 575 200 230 380 460 575 200 230 380 460 575 Maximum Horsepower 40 50 75 100 100 75 100 150 200 200 150 200 300 400 400 Open Type Type $ Price
135
WFO3a
10659.00
270
WGO3a
18678.00
540
WHO3Va
45666.00
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed on page 16-50. Replacement coils are listed on page 16-27.
Table 16.134: Class 9998Replacement Coils for Class 8702 Reversing Contactors
Size Type Poles Class & Type 9998WF 9998WG 9998WH Suffix Number (Complete Coil Number Consists of Class and Type Followed by Suffix Number) 120 Volts 110 Volts 120 120 120 240 Volts 220 Volts 240 240 240 480 Volts 440 Volts 480 480 480 600 Volts 550 Volts 600 600 600 $ Price
4 5 6
WF WG WH
114.00 503.00
.60
5.81
4.00
2.50
275.00
2.75 .86 0.38 1.76
1 2 3
V07
4 5 6 7 8 9 0 1 2
14.00
18.00
Approximate Dimensions
4.88 3.50
.44
1.5 Name Plate Recess For Auxiliary Interlock 4.20 2.50 4.26 24.00
overtravel gauge
1.89
2.48 3.75
3.98
1.40
9.56
6.00
8.80 max
6.88
7.00
1.44 1.44
Front View
Side View
3.40
3.90
3.75
22.00 24.00
1.40
7.75
CP1
Discount Schedule
16-49
16
2.70 2.70
6.50
Class 8738 and 8739 Type S reversing combination starters combine the requirements of motor overload and short circuit protection into one convenient package. Type S reversing combination starters are manufactured in accordance with NEMA standards, and are UL Listed (although some Form numbers may not be listedcontact your nearest Square D/Schneider Electric sales office for further information). Class 8738 and 8739 reversing combination starters are designed to operate at 600 Vac, 5060 Hzand are supplied with melting alloy overload relays as standard. For Class J fuses, use form Y1072 (No Charge).
Table 16.137: Class 8738 Full-Voltage Type, Fusible (With Class H Fuse Clips) Reversing with Melting Alloy Overload Relays3-Pole Polyphase600 Vac Maximum5060 Hz
Ratings Motor Voltage (Starter Voltage) Max. Hp Polyphase 3 5 7-1/2 200 (208) 10 20 40 75 3 5 7-1/2 230 (240) 15 25 50 100 5 10 15 460 (480) 25 50 100 200 5 10 15 575 (600) 25 50 100 a b Fuse Clip Size Amps 30 30 60 60 100 200 400 30 30 60 60 100 200 400 30 30 30 60 100 200 400 30 30 30 60 100 200 NEMA 1 General Purpose Enclosure NEMA 4 & 4X Watertight and Dusttight Enclosure Stainless Steel (304) Type SBW12b SCW12b SCW13b SDW12b SEW15b SFW15b SGW15b SBW12b SCW12b SCW13b SDW12b SEW15b SFW15b SGW15b SBW13b SCW14b SDW16b SDW14b SEW13b SFW13b SGW13b SBW13b SCW14b SDW16b SDW14b SEW13b SFW13b $ Price 3909.00 4050.00 4077.00 6501.00 11001.00 19277.00 40589.00 3909.00 4050.00 4077.00 6501.00 11001.00 19277.00 40589.00 3936.00 4077.00 6515.00 6543.00 11087.00 19332.00 41187.00 3936.00 4077.00 6515.00 6543.00 11087.00 19332.00 NEMA 4X Watertight, Dusttight and Corrosion Resistant Polyester Enclosure Type SBW22b SCW22b SCW23b SDW22b SBW22b SCW22b SCW23b SDW22b SBW23b SCW24b SDW26b SDW24b SBW23b SCW24b SDW26b SDW24b $ Price 4491.00 4656.00 4692.00 7149.00 4491.00 4656.00 4692.00 7149.00 4527.00 4692.00 7163.00 7199.00 4527.00 4692.00 7163.00 7199.00 NEMA 12/3Ra Dusttight and Driptight Industrial Use Enclosure With External Reset Type SBA22b SCA22b SCA23b SDA22b SEA25b SFA25b SGA25b SBA22b SCA22b SCA23b SDA22b SEA25b SFA25b SGA25b SBA23b SCA24b SDA26b SDA24b SEA23b SFA23b SGA23b SBA23b SCA24b SDA26b SDA24b SEA23b SFA23b Without External Reset Type SBA12b SCA12b SCA13b SDA12b SEA15b SFA15b SGA15b SBA12b SCA12b SCA13b SDA12b SEA15b SFA15b SGA15b SBA13b SCA14b SDA16b SDA14b SEA13b SFA13b SGA13b SBA13b SCA14b SDA16b SDA14b SEA13b SFA13b 2654.00 2798.00 2825.00 4478.00 7182.00 15672.00 30990.00 2654.00 2798.00 2825.00 4478.00 7182.00 15672.00 30990.00 2682.00 2825.00 4491.00 4521.00 7268.00 15728.00 31589.00 2682.00 2825.00 4491.00 4521.00 7268.00 15728.00
NEMA Size 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4
$ Price
Type SBG12b SCG12b SCG13b SDG12b SEG15b SFG15b SGG15b SBG12b SCG12b SCG13b SDG12b SEG15b SFG15b SGG15b SBG13b SCG14b SDG16b SDG14b SEG13b SFG13b SGG13b SBG13b SCG14b SDG16b SDG14b SEG13b SFG13b
$ Price 2169.00 2313.00 2340.00 3851.00 6357.00 13409.00 25605.00 2169.00 2313.00 2340.00 3851.00 6357.00 13409.00 25605.00 2199.00 2340.00 3873.00 3893.00 6443.00 13464.00 26204.00 2199.00 2340.00 3873.00 3893.00 6443.00 13464.00
200 5 400 SGG13b 26204.00 SGW13b 41187.00 SGA23b SGA13b 31589.00 NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. For class J fuse clip, use Form Y1072 (no charge). Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below.
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-50
CP1
Discount Schedule
NEMA Size 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 a b
$ Price
200 (208)
230 (240)
460 (480)
575 (600)
Type $ Price Type $ Price Type $ Price Type Type None SBG11b 2127.00 SBW11b 3866.00 SBW21b 4442.00 SBA21b SBA11b 2613.00 None SCG11b 2271.00 SCW11b 4008.00 SCW21b 4607.00 SCA21b SCA11b 2754.00 None SDG11b 3794.00 SDW11b 6443.00 SDW21b 7083.00 SDA21b SDA11b 4419.00 None SEG11b 6287.00 SEW11b 10929.00 SEA21b SEA11b 7113.00 None SFG11b 13166.00 SFW11b 19034.00 SFA21b SFA11b 15431.00 None SGG11b 25691.00 SGW11b 40674.00 SGA21b SGA11b 31076.00 None SBG11b 2127.00 SBW11b 3866.00 SBW21b 4442.00 SBA21b SBA11b 2613.00 None SCG11b 2271.00 SCW11b 4008.00 SCW21b 4607.00 SCA21b SCA11b 2754.00 None SDG11b 3794.00 SDW11b 6443.00 SDW21b 7083.00 SDA21b SDA11b 4419.00 None SEG11b 6287.00 SEW11b 10929.00 SEA21b SEA11b 7113.00 None SFG11b 13166.00 SFW11b 19034.00 SFA21b SFA11b 15431.00 None SGG11b 25691.00 SGW11b 40674.00 SGA21b SGA11b 31076.00 4442.00 SBA21b SBA11b 2613.00 None SBG11b 2127.00 SBW11b 3866.00 SBW21b None SCG11b 2271.00 SCW11b 4008.00 SCW21b 4607.00 SCA21b SCA11b 2754.00 None SDG11b 3794.00 SDW11b 6443.00 SDW21b 7083.00 SDA21b SDA11b 4419.00 None SEG11b 6287.00 SEW11b 10929.00 SEA21b SEA11b 7113.00 None SFG11b 13166.00 SFW11b 19034.00 SFA21b SFA11b 15431.00 None SGG11b 25691.00 SGW11b 40674.00 SGA21b SGA11b 31076.00 None SBG11b 2127.00 SBW11b 3866.00 SBW21b 4442.00 SBA21b SBA11b 2613.00 None SCG11b 2271.00 SCW11b 4008.00 SCW21b 4607.00 SCA21b SCA11b 2754.00 None SDG11b 3794.00 SDW11b 6443.00 SDW21b 7083.00 SDA21b SDA11b 4419.00 None SEG11b 6287.00 SEW11b 10929.00 SEA21b SEA11b 7113.00 None SFG11b 13166.00 SFW11b 19034.00 SFA21b SFA11b 15431.00 None SGG11b 25691.00 SGW11b 40674.00 SGA21b SGA11b 31076.00 NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown on page 16-59.
Table 16.140: Fusible Disconnect Switch Type With Class R Fuse Clips100,000 AIC Rating
Ratings Motor Voltage (Starter Voltage) Max. Hp PolyPhase 3 5 7-1/2 10 20 40 75 3 5 7-1/2 15 25 50 100 5 10 15 25 50 100 200 5 10 15 25 50 100 200 Fuse Clip Size Amps NEMA 1 General Purpose Enclosure NEMA 4 & 4X Watertight and Dusttight Enclosure Stainless Steel (304) NEMA 4X Watertight, Dusttight and Corrosion Resistant Polyester Enclosuree NEMA 12/3Rc Dusttight and Driptight Industrial Use Enclosure With External Reset Without External Reset
NEMA Size 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 c d e
$ Price
200 (208)
230 (240)
575 (600)
CP1
Discount Schedule
16-51
16
460 (480)
Type $ Price Type $ Price Type $ Price Type Type 30 SBG32d 2192.00 SBW32d 3929.00 SBW42d 4521.00 SBA42d SBA32d 2676.00 30 SCG32d 2334.00 SCW32d 4071.00 SCW42d 4685.00 SCA42d SCA32d 2817.00 60 SCG33d 2363.00 SCW33d 4100.00 SCW43d 4706.00 SCA43d SCA33d 2847.00 60 SDG32d 3873.00 SDW32d 6521.00 SDW42d 7176.00 SDA42d SDA32d 4499.00 6399.00 SEW35d 11043.00 SEA45d SEA35d 7226.00 100 SEG35d 200 SFG35d 13451.00 SFW35d 19319.00 SFA45d SFA35d 15714.00 400 SGG35d 25707.00 SGW35d 40689.00 SGA45d SGA35d 31089.00 30 SBG32d 2192.00 SBW32d 3929.00 SBW42d 4521.00 SBA42d SBA32d 2676.00 30 SCG32d 2334.00 SCW32d 4071.00 SCW42d 4685.00 SCA42d SCA32d 2817.00 60 SCG33d 2363.00 SCW33d 4100.00 SCW43d 4706.00 SCA43d SCA33d 2847.00 60 SDG32d 3873.00 SDW32d 6521.00 SDW42d 7176.00 SDA42d SDA32d 4499.00 100 SEG35d 6399.00 SEW35d 11043.00 SEA45d SEA35d 7226.00 200 SFG35d 13451.00 SFW35d 19319.00 SFA45d SFA35d 15714.00 400 SGG35d 25707.00 SGW35d 40689.00 SGA45d SGA35d 31089.00 30 SBG33d 2219.00 SBW33d 3959.00 SBW43d 4548.00 SBA43d SBA33d 2705.00 30 SCG34d 2363.00 SCW34d 4100.00 SCW44d 4712.00 SCA44d SCA34d 2847.00 30 SDG36d 3893.00 SDW36d 6534.00 SDW46d 7191.00 SDA46d SDA36d 4514.00 60 SDG34d 3915.00 SDW34d 6564.00 SDW44d 7433.00 SDA44d SDA34d 4541.00 100 SEG33d 6485.00 SEW33d 11129.00 SEA43d SEA33d 7311.00 200 SFG33d 13508.00 SFW33d 19376.00 SFA43d SFA33d 15771.00 400 SGG33d 26303.00 SGW33d 41288.00 SGA43d SGA33d 31688.00 30 SBG33d 2219.00 SBW33d 3959.00 SBW43d 4548.00 SBA43d SBA33d 2705.00 30 SCG34d 2363.00 SCW34d 4100.00 SCW44d 4712.00 SCA44d SCA34d 2847.00 30 SDG36d 3893.00 SDW36d 6534.00 SDW46d 7191.00 SDA46d SDA36d 4514.00 60 SDG34d 3915.00 SDW34d 6564.00 SDW44d 7433.00 SDA44d SDA34d 4541.00 100 SEG33d 6485.00 SEW33d 11129.00 SEA43d SEA33d 7311.00 200 SFG33d 13508.00 SFW33d 19376.00 SFA43d SFA33d 15771.00 400 SGG33d 26303.00 SGW33d 41288.00 SGA43d SGA33d 31688.00 NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown on page 16-52. 5,000 AIC Rating
Ratings
Hp Range Polyphase 1/43 1/45 7-1/2 1-1/25 71/210 1525 3040 5060 75 100 125150 1/43 1/47-1/2 1-1/27-1/2 10 15 1530 4050 60 75100 125150 200
NEMA Size 0 1 2 3 4 5 6 0 1 2 3 4 5 6
Type
$ Price
Type
$ Price
Type
Bolted Type
$ Price
$ Price
200 (208)
230 (240)
HLL36030M71 SBG43d 2555. SBW43d 4292. SBW53d 4932. SBA53d SBA43d HLL36030M71 SCG44d SCW44d SCA54d SCA44d 2726. SCW45d 4463. SCW54d 5133. HLL36050M72 SCG45d SCW55d SCA55d SCA45d HLL36030M71 SDG42d SDA52d SDA42d 4350. SDW42d 6998. SDW52d 7695. HLL36050M72 SDG43d SDW43d SDW53d SDA53d SDA43d HLL36100M73 SEG42d 6501. SEW42d 11142. SEW52d 12254. SEA52d SEA42d JJL36250M75 SFG44d 14718. SFW44d 20586. SFW54d 22644. SFA54d SFA44d JLL36250M75 SGG44d 29808. SGW44d 44792. SGA54d SGA44d DJL36400M36 SGG45d SGW45d SGA55d SGA45d DJL36400M36 SHG43d 64274. SHW43d 71396. SHA53d SHA43d DJL36600M42 SHG45d SHW45d SHA55d SHA45d See Digest 175 Page 16-52Page 16-55 HLL36030M71 SBG43d 2555. SBW43d 4292. SBW53d 4932. for catalog number contact CIC for pricing. SBA53d SBA43d HLL36030M71 SCG44d 2726. SCW44d 4463. SCW54d 5133. SCA54d SCA44d HLL36030M71 SDG42d SDW42d SDW52d SDA52d SDA42d HLL36050M72 SDG43d 4350. SDW43d 6998. SDW53d 7695. SDA53d SDA43d HLL36100M73 SDG44d SDW44d SDW54d SDA54d SDA44d HLL36100M73 SEG42d 6501. SEW42d 11142. SEW52d 12254. SEA52d SEA42d JJL36250M75 SFG44d 14718. SFW44d 20586. SFW54d 22644. SFA54d SFA44d JLL36250M75 SGG44d 29808. SGW44d 44792. SGA54d SGA44d DJL36400M36 SGG45d SGW45d SGA55d SGA45d SHA55d SHA45d DJL36600M42 SHG45d 64274. SHW45d 71396. SHW46d SHA56d SHA46d PLL34080M68 SHG46d a NEMA Size 6 starters are NEMA 4 painted sheet steel enclosures. b NEMA 7 & 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed below.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-52
CP1
Discount Schedule
Ratings
Hp Range Polyphase 1/45 1/410 515 2025 2025 3050 60100 125 150200 250350 400 1/45 1/410 520 25 2530 4050 60100 125150 200 250 300400
NEMA Size 0 1 2 3 4 5 6 0 1 2 3 4 5 6
Type
$ Price
Type
$ Price
Type
Bolted Type
$ Price
$ Price
460 (480)
575 (600)
HLL36030M71 SBG43d 2555. SBW43d 4292. SBW53d 4932. SBA53d SBA43d HLL36030M71 SCG44d 2726. SCW44d 4463. SCW54d 5133. SCA54d SCA44d HLL36030M71 SDG42d SDA52d SDA42d 4350. SDW42d 6998. SDW52d 7695. HLL36050M72 SDG43d SDW43d SDW53d SDA53d SDA43d HLL36050M72 SEG41d SEW41d 11142. SEW51d 12254. SEA51d SEA41d 6501. SEW42d HLL36100M73 SEG42d SEW52d SEA52d SEA42d JLL36250M75 SFG44d 14718. SFW44d 20586. SFW54d 22644. SFA54d SFA44d JLL36250M75 SGG44d 29808. SGW44d 44792. SGA54d SGA44d DJL36400M36 SGG45d SGW45d SGA55d SGA45d DJL36600M42 SHG45d 64274. SHW45d 71396. SHA55d SHA45d PLL34080M68 SHG46d SHW46d SHA46d See Digest 175 Page 16-52Page 16-55 SHA56d for catalog number contact CIC for pricing. SBA53d HLL36030M71 SBG43d 2555. SBW43d 4292. SBW53d 4932. SBA43d HLL36030M71 SCG44d 2726. SCW44d 4463. SCW54d 5133. SCA54d SCA44d HLL36030M71 SDG42d SDA52d SDA42d 4350. SDW42d 6998. SDW52d 7695. HLL36050M72 SDG43d SDW43d SDW53d SDA53d SDA43d HLL36050M72 SEG41d SEW41d 11142. SEW51d 12254. SEA51d SEA41d 6501. SEW42d HLL36100M73 SEG42d SEW52d SEA52d SEA42d JLL36250M75 SFG44d 14718. SFW44d 20586. SFW54d 22644. SFA54d SFA44d JLL36250M75 SGG44d 29808. SGW44d 44792. SGA54d SGA44d DJL36400M36 SGG45d SGW45d SGA55d SGA45d SHG43d 64274. SHW43d 71396. SHA53d SHA43d DJL36400M36 DJL36600M42 SHG45d SHW45d SHA55d SHA45d a NEMA Size 6 starters are NEMA 4 painted sheet steel enclosures. b NEMA 7 & 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed below.
CP1
Discount Schedule
16-53
16
Ratings
Max. Hp Polyphase 2 3 5 7-1/2 10 15 20 25 30 40 50 6075 100125 150 2 3 5 7-1/2 10 15 20 2530 40 50 60 75 100 125 150200
NEMA Size
Bolted Type
$ Price
200 (208)
230 (240)
HLL36060 60 SDG1d SDA11d SDA1d 4022. SDW1d 6672. SDW11d 7340. 4649. HLL36090 90 SDG7d SDW7d SDW17d SDA17d SDA7d HLL36100 100 SEG3d SEW3d SEW13d SEA13d SEA3d 6501. SEW5d 11142. SEW15d 12254. 7326. HLL36150 150 SEG5d SEA15d SEA5d JLL36225 225 SFG1d SFA11d SFA1d 16982. 14718. SFW1d 20586. SFW11d 22644. JLL36250 250 SFG4d SFW4d SFW14d SFA14d SFA4d JLL36250 250 SGG6d SGW6d SGA16d SGA6d DLL36400E20 400 SGG4d 29808. SGW4d 44792. SGA14d SGA4d 35190. DLL36600E20 600 SGG2d SGW2d SGA12d SGA2d DLL36600E20 600 SHG4d SHW4d SHA14d SHA4d 68120. 64274. SHW5d 71396. MJL36800 800 SHG5d SHA15d SHA5d a NEMA Size 6 starters are NEMA 4 painted sheet steel enclosures. b NEMA 7 and 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information. d Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. e Rated 250 volts max.
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8739SBG1V01S). g These voltage codes must include Form S (supplied at no charge) (i.e., order as 8739SCG5V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-56 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-54
CP1
Discount Schedule
Ratings
NEMA Size
Bolted Type
460 (480)
CP1
Discount Schedule
16-55
16
15 HLL36035 35 SDG8d SDW8d SDW18d SDA18d SDA8t 20 2 HLL36045 45 SDG3d 4350. SDW3d 6998. SDW13d 7695. SDA13d SDA3d 25 HLL36060 60 SDG1d SDW1d SDW11d SDA12d SDA1d 30 HLL36070 70 SEG4d SEW4d SEW14d SEA14d SEA4d 575 40 3 HLL36090 90 SEG6d 6501. SEW6d 11142. SEW16d 12254. SEA16d SEA6d (600) 50 HLL36100 100 SEG3d SEW3d SEW13d SEA13d SEA3d 6075 JLL36150 150 SFG5d SFW5d SFW15d 22644. SFA15d SFA5d 4 14718. SFW4d 20586. SFW14d 100 JLL36250 250 SFG4d SFA14d SFA4d 125150 JLL36250 250 SGG6d SGA16d SGA6d 5 29808. SGW6d 44792. 200 DLL36400E20 400 SGG4d SGW4d SGA14d SGA4d 250350 DLL36600E20 600 SHG4d SHA14d SHA4d 6 64274. SHW4d 71396. 400 MJL36800 800 SHG5d SHW5d SHA15d SHA5d a NEMA Size 6 starters are NEMA 4 painted sheet steel enclosures. Table 16.149: Class 8739 UL Listed Short Circuit Ratings b NEMA 7 and 9 bolted are not UL Listed. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-serviceMotor Circuit Protector Type entrance-rated applications; see page 16-104 for more information. NEMA Amps Interrupting d Coil voltage code must be specified to order this product. Refer to standard coil voltage Voltage Enclosure Size Capability Rating (AIC) codes shown below. 0, 1 480 Standardh 100,000 Table 16.147: Class 8738 UL Listed Short Circuit Ratings 0, 1 481 600 Standardh 35,000 NEMA Fuse Clip Amps Interrupting 2, 3, 4, 5 480 Standardh 100,000 Enclosure Size Type Capability Rating (AIC) 2, 3, 4, 5 481 600 Standardh 50,000 0-3 Standard Standarde 5,000 6, 7 480 Standardh 65,000 0-3 Class R Standarde 100,000 6 600 Standardh 18,000 4-5 Standard Standarde 10,000 7 600 Standardh 30,000 4-5 Class R Standarde 100,000 Thermal Magnetic Circuit Breaker Type e Standard enclosure includes: NEMAs 1, 4 & 4X stainless, and 12/3R. 0, 1 480 Standardh 100,000 0, 1 481 600 Standardh 35,000 Table 16.148: Coil Voltage Codes 2, 3, 4, 5 480 Standardh 100,000 Voltage 2, 3, 4, 5 481 600 Standardh 50,000 Code $ Price Adder 60 Hz 50 Hz 6, 7 480 Standardh 65,000 24gf V01 No Charge 6 600 Standardh 18,000 120g 110 V02 No Charge 7 600 Standardh 30,000 208 V08 No Charge h Standard enclosure includes: NEMAs 1, 4 & 4X stainless, and 12/3R. 240 220 V03 No Charge 480 440 V06 No Charge 600 550 V07 No Charge Specify Specify V99 35.60 f 24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, For How to Order Information, see page 16-12. Form S (separate control) must be specified (i.e., order as 8739SBG2V01S). g These voltage codes must include Form S (supplied at no charge) (i.e., order as 8739SDG3V02S). Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge.
Approximate Dimensions
Table 16.150: NEMA 1 Enclosure (Size 02) Figure 1
NEMA Size 01 2 Class 8738 & 8739 8738 & 8739 Type SBG SCG SDG Dimensions (in inches)csee Figure 1 A 13-3/4 15 B 23 C D E 21 F 18-29/32 G 1-7/8 H 1-7/8 2 I J K L M N O 7/8 29/32 P Top & Bottom W X Sides Y 1/2 1/2 Wt. (lbs.) 49 80
8-11/32 10-5/8
3-3/4 2-5/16 1-1/16 3-1/4 2-3/16 1-1/4 4 2-9/16 1-1/4 3-1/4 2-3/16 1-1/4
10-19/32 12-1/2 15
2-11/16 5-3/8 1-7/32 29/32 2-11/16 5-3/8 1-7/32 29/32 2-11/16 5-3/8 1-7/32 29/32 3-3/16 3-3/16
51-1/2 10-17/32 44 77 65 90
4 8739 8738 5 8739 6 13-23/32 17-1/32 22 39-13/32 64 6-9/32 5 10-19/32 12-1/2 15-1/2 22 25-31/32 43-1/2 39-13/32 76
6-9/32 9-1/4
C B
NOTE: Illustrations may not represent the actual enclosure; they are intended for dimensional information only.
A D
M K
Handle Swing L
C N Y O
A D
Handle Swing L H
C O Y P A F E H
Handle Swing D
16
E B
G B G C
Y
Y
(4) .31 Dia. Mtg. Holes 8 (For Sizes 0, 1, and 2)
Cover Open 90 F W X W G J H I
Cover Open 90 F W X W J K M N
(4) .44 Dia. Mtg. Holes 11 (For Sizes 3 and 4) (4) .56 Dia. Mtg. Holes Located on 14 External Flanges (For Size 5)
Cover Open 90 J
(4) .31 Dia. Mtg. Holes 8 (For Sizes 0, 1, and 2) (4) .44 Dia. Mtg. Holes 11 (For Sizes 3 and 4) (4) .56 Dia. Mtg. Holes Located on 14 External Flanges (For Size 5)
16-56
Approximate Dimensions
Table 16.154: NEMA 4 & 4X Stainless Enclosure Figure 1
NEMA Size 01 2 3 4 8739 8738 5 8739 6 a 8739 SGW SHW 30 36 13-57/64 17-1/32 66-3/32 98 5 4 22 65 9/16 6-3/32 3 3-1/2 37-7/8 3/4 Hub 3-1/2 Hub SFW SGW 18-1/2 30 10-9/16 15-1/2 45-3/16 78-3/32 5 9-1/4 3 4 12-1/2 22 44 77 19/32 9/16 3-1/2 6-3/32 2-5/8 3 3-3/16 3-1/2 25-1/2 39-13/32 3/4 Hub 2-1/2 Hub 3/4 Hub 3-1/2 Hub Class 8738 & 8739 8738 & 8739 8738 & 8739 8738 Type A SBW SCW SDW SEW SFW 13-3/4 15 18-1/2 21 B 8-11/32 9-19/32 10-9/16 10-17/32 C 25-3/16 30-1/32 45-3/16 52-11/16 D 3-1/4 3-1/4 5 5 Dimensions (in inches)asee Figure 1 E 2-1/2 2-1/2 3 3 F 8-3/4 10 12-1/2 15 G 24 29-3/4 44 51-1/2 H 19/32 5/8 19/32 19/32 I 3 3 3-1/2 3-1/2 J 1-5/8 2 2-5/8 2-5/8 K 2-5/16 2-5/8 3-3/16 3-3/16 L 18-17/32 21-1/32 25-1/2 30-1/4 Bottom W 3/4 Hub Top & Bot. X 1 Hub Wt. (lbs.) 52 95 255
3/4 Hub 1-1/2 Hub 3/4 Hub 2-1/2 Hub 3/4 Hub 2-1/2 Hub
Above dimensions also for Form F4T (standard control transformer), Form F4T11 (100 VA extra capacity) and Form F4T12 (200 VA extra capacity).
NOTE: Illustrations may not represent the actual enclosure; they are intended for dimensional information only.
Information on Hubs
Hubs are supplied with each NEMA 4X combination starter as shown in the table below. Note that hubs are only installed in stainless steel enclosures; they are not installed in polyester enclosures. Table 16.157:
NEMA Size 0&1 2 3&4 Quantity 1 2 1 2 1 2 Hub Size 0.75" 1.00" 0.75" 1.50" 0.75" 2.50"
L H A F E H Handle Swing D B N
Top View
E Q
G C S G T J P (4) Mtg. for Bolts (4) .31 Dia. Mtg. Holes (for Size 0, 1, & 2) 8 Cover Open 90 (4) .44 Dia. Mtg. Holes (for Size 3 & 4) 11 (4) .56 Dia. Mtg. Holes Located on 14 External Flanges (for Size 5) W X J I K
Q .19 5
R (2) "Z" Pipe Tap Top and Bottom K 1/2" NPT for Breather and Drain
Circuit Breaker Operator Handle - Combination Form Only (Add 1 IN to overall width) Space Required to Remove Bottom Cover
16-57
16
Application Data
Multispeed motors are available in two basic versions: 1) Consequent pole, and 2) separate winding. A separate winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds (three speed motors have two windings). The motor connections (and thus the types of controllers) for two speed starters are exemplified by the schematic diagrams shown below. Note that consequent pole two speed controllers involve a 5-pole and a 3-pole starter while separate winding controllers have two 3-pole starters. The type of motor must be verified prior to ordering. Field modification of starters to match the motor may not be possible. Separate winding motors are usually chosen when flexibility is important, since the speeds of a consequent pole motor are usually limited to a 2/1 ratio; a broad range of speeds can be obtained on a separate winding motor. Table 16.159: Typical Schematic Diagrams
HIGH 4 LOW L 2 HIGH 3 L H L1 L2 L3
L1 L2 L3
Both consequent pole and separate winding motors are available in three types: 1) Constant horsepower, 2) Constant torque, and 3) Variable torque. Typical applications for these different types of motors are shown below. Note: For detailed information involving the technical aspects of flexibility of the starters used in the multispeed controllers, see Classes 8702, 8736 and 8810 application data. Table 16.158: Typical Applications
Constant Hp Constant Torque Variable Torque
1 STOP
5 H
OL OL
1 STOP
HIGH 4
LOW L
5 H
OL OL
1 STOP
H
HIGH 4
LOW 5 L
OLOL
HIGH 3 L H
HIGH L 3 H
L1
L OL H L L H H H
H OL
L2 L3
OL OL OL
OL OL L L
OL OL H
OL OL OL
OL OL OL
OL OL OL
T1
T1 T2 T3 T6 T4 T5
T1 T2 T3 T6 T4 T5
T2 T3
2-Speed Consequent Pole Constant Horsepower NEMA Size 0-4 Sizes 5, 6 & 7 Use Special Circuitry
2-Speed Consequent Pole Constant or Variable Torque NEMA Size 0-4 Sizes 5, 6 & 7 Use Special Circuitry
2-Speed Separate Winding Constant Hp, Constant Torque and Variable Torque NEMA Size 0-4 Sizes 5, 6 & 7 Use Special Circuitry
Form R3 Decelerating Relay/Timer. This is similar in action to Form R2 accelerating relays, except that they function to prevent immediate transfer from a higher to a lower speed. A definite time interval, preset on the timer, must elapse between each speed change. Form R10 Antiplugging Relays/Timers. This form imposes a time delay when transferring from the forward to the reverse direction or reverse to forward, for reversing multispeed starters. This provides up to a 60 second delay in the transfer of the direction of the motor, and can help prevent damage which could result from plugging. Overload Relay Modification. Form Y81 (Low Speed) For NEMA size 3 and 4, when the low speed full load current does not appear on the appropriate thermal unit selection tables, include Form Y81 (Low Speed) (No Charge for this form). This form modifies the overload relay block to accept Type B thermal units. Consult your nearest Square D/Schneider Electric sales office for assistance on thermal unit selection.
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-58
Multispeed motors are available in two basic versions: 1) Consequent pole, and 2) separate winding. A separate winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds (three speed motors have two windings).
Type of Motor
NEMA Size
Open Type
Type
$ Price
Type
$ Price
Type
$ Price
Type
$ Price
Constant Hp
SBG1c SCG1c SDG1c SEG1c SFG1c SGG1c SHG1c SBG2c SCG2c SDG2c SEG2c SFG2c SGG2c SHG2c SBG3c SCG3c SDG3c SEG3c SFG3c SGG3c SHG3c SJG3c SBG4c SCG4c SDG4c SEG4c SFG4c SGG4c SHG4c SJG4c
2199. 2370. 4307. 6501. 17352. 34286. 77286. 2199. 2370. 4307. 6501. 17352. 34286. 77286. 1571. 1772. 3167. 4962. 12168. 28718. 58755. 76032. 1571. 1772. 3167. 4962. 12168. 28718. 58755. 76032.
SBW1c SCW1c SDW1c SEW1c SFW1c SGW1c SHW1c SBW2c SCW2c SDW2c SEW2c SFW2c SGW2c SHW2c SBW3c SCW3c SDW3c SEW3c SFW3c SGW3c SHW3c SBW4c SCW4c SDW4c SEW4c SFW4c SGW4c SHW4c
Constant Hp b
Single Winding (Consequent Pole) 5-Pole3-Pole 3567. SBW51c 4100. SBA1c 3708. SCW51c 4278. SCR1c 5895. SCA1c 5958. SDW51c 6557. SDR1c 10947. SDA1c 8837. SEA1c 22365. SFA1c 46008. SGA1c 93308. SHA1c 3567. SBW52c 4100. SBA2c 3708. SCW52c 4278. SCR2c 5895. SCA2c 5958. SDW52c 6557. SDR2c 10947. SDA2c 8837. SEA2c 22365. SFA2c 46008. SGA2c 93308. SHA2c Two Winding (Separate Winding) 3-Pole3-Poleb 2939. SBW53c 3384. SBA3c 3110. SCW53c 3567. SCR3c 4968. SCA3c 3231. SDW53c 3564. SDR3c 5264. SDA3c 7412. SEA3c 17181. SFA3c 40440. SGA3c 66090. SHA3c SJA3c 2939. SBW54c 3384. SBA4c 3110. SCW54c 3567. SCR4c 4968. SCA4c 3231. SDW54c 3564. SDR4c 5264. SDA4c 7412. SEA4c 17181. SFA4c 40440. SGA4c 66090. SHA4c SJA4c
2640. 2811. 4932. 7925. 20172. 46008. 83753. 2640. 2811. 4932. 7925. 20172. 46008. 83753. 2015. 2213. 2529. 6386. 14988. 40440. 65195. 82826. 2015. 2213. 2529. 6386. 14988. 40440. 65195. 82826.
SBO1c SCO1c SDO1c SEO1c SFO1c SGO1c SHO1c SBO2c SCO2c SDO2c SEO2c SFO2c SGO2c SHO2c SBO3c SCO3c SDO3c SEO3c SFO3c SGO3c SHO3c SJ03c SBO4c SCO4c SDO4c SEO4c SFO4c SGO4c SHO4c SJO4c
2142. 2285. 4050. 6101. 15786. 31197. 70799. 2142. 2285. 4050. 6101. 15786. 31197. 70799. 1515. 1686. 1956. 4590. 11429. 26994. 51848. 69195. 1515. 1686. 1956. 4590. 11429. 26994. 51848. 69195.
Table 16.162: Class 8810Combination Circuit Breaker Type (Thermal Magnetic Breakers)ae
Single Winding (Consequent Pole) 5-Pole3-Pole 6429. CBW51c 6962. CBA1c 4676. 6566. CCW51c 7140. CCR1c 8757. CCA1c 4867. Constant 10089. CDW51c 10089. CDR1c 14705. CDA1c 7497. Hp 13836. CEA1c 10787. 29460. CFA1c 26753. 57816. CGA1c 56847. 68843. CHA1c 65841. 0 3 3 5 6429. CBW52c 6962. CBA2c 4676. Constant 1 7-1/2 7-1/2 10 6566. CCW52c 7140. CCR2c 8757. CCA2c 4867. Torque 2 10 15 25 10089. CDW52c 10089. CDR2c 14705. CDA2c 7497. or 3 25 30 50 13836. CEA2c 10787. Variable 4 40 50 100 29460. CFA2c 26753. Torque 5 75 100 200 57816. CGA2c 56847. 6 150 200 400 68843. CHA2c 65841. Two Winding (Separate Winding) 3-Pole3-Poleb 0 2 2 3 4050. CBG3c 3581. CBW3c 5801. CBW53c 6251. CBA3c 1 5 5 7-1/2 4248. CCG3c 3780. CCW3c 5972. CCW53c 6429. CCR3c 7830. CCA3c Constant 2 7-1/2 10 20 6357. CDG3c 5616. CDW3c 8379. CDW53c 8879. CDR3c 11429. CDA3c Hp 3 20 25 40 9248. CEG3c 7626. CEW3c 12297. CEA3c b 4 30 40 75 CFG3c 17040. CFW3c 16182. CFA3c 14379. 5 60 75 150 CGG3c 38190. CGW3c 52248. CGA3c 51278. 6 100 150 300 CHG3c 72629. CHW3c 84306. CHA3c 80199. 7 225 450 CJG3c 95358. CJA3c 103217. 0 3 3 5 CBG4c 3581. CBW4c 5801. CBW54c 6251. CBA4c 4050. Constant 1 7-1/2 7-1/2 10 CCG4c 3780. CCW4c 5972. CCW54c 6429. CCR4c 7830. CCA4c 4248. Torque 2 10 15 25 CDG4c 5616. CDW4c 8379. CDW54c 8879. CDR4c 11429. CDA4c 6357. or 3 25 30 50 CEG4c 7626. CEW4c 12297. CEA4c 9248. Variable 4 40 50 100 CFG4c 17040. CFW4c 16182. CFA4c 14379. Torque 5 75 100 200 CGG4c 38190. CGW4c 52248. CGA4c 51278. b 6 150 200 400 CHG4c 72629. CHW4c 84306. CHA4c 80199. 7 300 600 CJG4c 95358. CJA4c 103217. a The NEC 1300% maximum setting for instantaneous trip circuit breakers may be inadequate for multispeed motors. b Prices and type numbers shown for three phase, separate-winding motor starters apply only when motor windings are Wye connected. When motor windings are connected open delta, use the prices shown for three phase consequent pole motor starters. c Voltage code must be specified to order this product. Refer to standard voltage codes shown on page 16-60. d NEMA 4X hubs are included with each starter at no additional cost. e Not available in Mag-Gard versions. f NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See page 16-104 for more information. 0 1 2 3 4 5 6 2 5 7-1/2 20 30 60 100 2 5 10 25 40 75 150 3 7-1/2 20 40 75 150 300 CBG1c CCG1c CDG1c CEG1c CFG1c CGG1c CHG1c CBG2c CCG2c CDG2c CEG2c CFG2c CGG2c CHG2c 4206. 4377. 6758. 9162. 22224. 43758. 91229. 4206. 4377. 6758. 9162. 22224. 43758. 91229. CBW1c CCW1c CDW1c CEW1c CFW1c CGW1c CHW1c CBW2c CCW2c CDW2c CEW2c CFW2c CGW2c CHW2c
CP1
Discount Schedule
16-59
16
2 5 7-1/2 20 30 60 100
2 5 10 25 40 75 150
3 7-1/2 10 25 40 75 150
UBG1b DBG1b UCG1b DCG1b UDG1b DDG1b UEG1b DEG1b UFG1b DFG1b UGG1b DGG1b UHG1b DHG1b UBG2b DBG2b UCG2b DCG2b UDG2b DDG2b UEG2b DEG2b UFG2b DFG2b UGG2b DGG2b UHG2b DHG2b UBG3b DBG3b UCG3b DCG3b UDG3b DDG3b UEG3b DEG3b UFG3b DFG3b UGG3b DGG3b UHG3b DHG3b UBG4b DBG4b UCG4b DCG4b UDG4b DDG4b UEG4b DEG4b UFG4b DFG4b UGG4b DGG4b UHG4b DHG4b
None 30 None 1 5 5 7-1/2 30 None 2 7-1/2 10 20 Constant 60 Horsepower None 3 20 25 40 a 100 None 4 30 40 75 200 None 5 60 75 150 400 None 6 100 150 300 600 None 0 3 3 5 30 None 1 7-1/2 7-1/2 10 30 None Constant 2 10 15 25 60 Torque or None 3 25 30 50 Variable 100 Torque None 4 40 50 100 a 200 None 5 75 100 200 400 None 6 150 200 400 600 a Prices and type numbers shown for three phase, separate-winding motor starters apply only when motor windings are Wye connected. When motor windings are connected open delta use the prices shown for three phase consequent pole motor starters. b Voltage code must be specified to order this product. Refer to standard voltage codes shown below. c NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See page 16-104 for more information. 0 2 2 3 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-62 Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-117
Single Winding (Consequent Pole) 5-Pole3-Pole 3537.00 UBW1b 5759.00 UBA1b 3765.00 DBW1b 5988.00 DBA1b 3708.00 UCW1b 5903.00 UCA1b 3936.00 DCW1b 6129.00 DCA1b 6015.00 UDW1b 8751.00 UDA1b 6129.00 DDW1b 8864.00 DDA1b 8666.00 UEW1b 13337.00 UEA1b 8837.00 DEW1b 13508.00 DEA1b 19517.00 UFW1b 27693.00 UFA1b 20970.00 DFW1b 25964.00 DFA1b 39644.00 UGW1b 35799.00 UGA1b 40154.00 DGW1b 54212.00 DGA1b 87789.00 UHW1b 99824.00 UHA1b 91085.00 DHW1b 103121.00 DHA1b 3537.00 UBW2b 5759.00 UBA2b 3765.00 DBW2b 5988.00 DBA2b 3708.00 UCW2b 5903.00 UCA2b 3936.00 DCW2b 6129.00 DCA2b 6015.00 UDW2b 8751.00 UDA2b 6129.00 DDW2b 8864.00 DDA2b 8666.00 UEW2b 13337.00 UEA2b 8837.00 DEW2b 13508.00 DEA2b 19517.00 UFW2b 27693.00 UFA2b 20970.00 DFW2b 25964.00 DFA2b 39644.00 UGW2b 35799.00 UGA2b 40154.00 DGW2b 54212.00 DGA2b 87789.00 UHW2b 99824.00 UHA2b 91085.00 DHW2b 103121.00 DHA2b Two Winding (Separate Winding) 3-Pole3-Pole 2910.00 UBW3b 5133.00 UBA3b 3140.00 DBW3b 5360.00 DBA3b 3110.00 UCW3b 5304.00 UCA3b 3338.00 DCW3b 5531.00 DCA3b 4877.00 UDW3b 7640.00 UDA3b 4991.00 DDW3b 7754.00 DDA3b 7127.00 UEW3b 11798.00 UEA3b 7866.00 DEW3b 11969.00 DEA3b 15159.00 UFW3b 22509.00 UFA3b 17324.00 DFW3b 23021.00 DFA3b 34073.00 UGW3b 48131.00 UGA3b 34586.00 DGW3b 48644.00 DGA3b 69188.00 UHW3b 80868.00 UHA3b 72485.00 DHW3b 84164.00 DHA3b 2910.00 UBW4b 5133.00 UBA4b 3140.00 DBW4b 5360.00 DBA4b 3110.00 UCW4b 5304.00 UCA4b 3338.00 DCW4b 5531.00 DCA4b 4877.00 UDW4b 7640.00 UDA4b 4991.00 DDW4b 7754.00 DDA4b 7127.00 UEW4b 11798.00 UEA4b 7866.00 DEW4b 11969.00 DEA4b 15159.00 UFW4b 22509.00 UFA4b 17324.00 DFW4b 23021.00 DFA4b 34073.00 UGW4b 48131.00 UGA4b 34586.00 DGW4b 48644.00 DGA4b 69188.00 UHW4b 80868.00 UHA4b 72485.00 DHW4b 84164.00 DHA4b
4008.00 4235.00 4179.00 4406.00 6758.00 6870.00 10287.00 10458.00 24987.00 22500.00 34622.00 52446.00 95324.00 98621.00 4008.00 4235.00 4179.00 4406.00 6758.00 6870.00 10287.00 10458.00 24987.00 22500.00 34622.00 52446.00 95324.00 98621.00 3380.00 3609.00 3581.00 3807.00 5616.00 5732.00 8751.00 9491.00 19803.00 21852.00 50439.00 50952.00 76766.00 80063.00 3380.00 3609.00 3581.00 3807.00 5616.00 5732.00 8751.00 9491.00 19803.00 21852.00 50439.00 50952.00 76766.00 80063.00
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-60
CP1
Discount Schedule
Type of Motor
NEMA Size
Type SBO21c SCO21c SDO21c SEO21c SFO21c SGO21c SBO22c SCO22c SDO22c SEO22c SFO22c SGO22c SBO23c SCO23c SDO23c SEO23c SFO23c SGO23c SBO24c SCO24c SDO24c SEO24c SFO24c SGO24c
$ Price 3851. 4121. 6501. 9662. 19718. 42164. 3851. 4121. 6501. 9662. 19718. 42164. 3167. 3324. 5432. 8267. 15188. 33048. 3167. 3324. 5432. 8267. 15188. 33048.
Type SBO31c SCO31c SDO31c SEO31c SFO31c SGO31c SBO32c SCO32c SDO32c SEO32c SFO32c SGO32c SBO33c SCO33c SDO33c SEO33c SFO33c SGO33c SBO34c SCO34c SDO34c SEO34c SFO34c SGO34c
$ Price 4449. 4791. 8010. 11997. 24930. 52659. 4449. 4791. 8010. 11997. 24930. 52659. 4077. 4449. 7554. 11228. 20487. 43388. 4077. 4449. 7554. 11228. 20487. 43388.
0 2 2 3 3 SBO11c 2142.00 SBO13c 1515.00 1 5 5 7-1/2 7-1/2 SCO11c 2282.00 SCO13c 1686.00 Constant 2 7-1/2 10 20 20 SDO11c 4050.00 SDO13c 2939.00 Horsepower 3 20 25 40 40 SEO11c 6101.00 SEO13c 4563.00 4 30 40 60 75 SFO11c 15786.00 SFO13c 11429.00 Constant 0 3 3 5 5 SBO12c 2142.00 SBO14c 1515.00 Torque 1 7-1/2 7-1/2 10 10 SCO12c 2282.00 SCO14c 1686.00 or 2 10 15 25 25 SDO12c 4050.00 SDO14c 2939.00 Variable 3 25 30 50 50 SEO12c 6101.00 SEO14c 4563.00 Torque 4 40 50 75 100 SFO12c 15786.00 SFO14c 11429.00 a Prices and type numbers shown for three phase, separate winding motor starters apply only when motor windings are Wye connected. When motor windings are connected open delta use the prices shown for consequent pole motor starters. b Specify the speed which requires reversing by adding an L (low) or an H (high) after the type number, e.g., a Class 8810 Type SBG21 with reversing in low only would be ordered as a Class 8810 Type SBG21L. c Voltage codes must be specified to order this product. Refer to standard voltage codes listed below.
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-62 Factory Modifications (Forms). . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-109 Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . . . . page 16-114 Type S Accessories (Class 9999). . . . . . . . . . . . . . . . . . . . . . . . page 16-117
CP1
Discount Schedule
16-61
16
24 V coils are not available on Sizes 47. On Sizes 003, where 24 V coils are available, Form S (separate control) must be specified (i.e., order as 8810SCG21V01S). e These voltage codes must include Form S (supplied at no charge) (i.e., order as 8810SDG21V02S). f NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See page 16-104 for more information. Note: For voltage codes used with control transformers, see page 16-110. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge.
A D
GB
RESET
7/16 9/16
Consult Square D
SEW3 & 4 and SFW3 & 4 18-5/32 32-7/32 SEW1 & 2 and SFW1 & 2 22-5/32 42-7/32 SGW1, 2, 3, 4 35-7/32 49-7/32
D F
I H B
RESET
N L P J Travel M
7c SJO3, 4 Consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733). Consequent pole type starters consist of two 3-pole starters as pictured in Figure 4 and an additional 2-pole shorting contactor (not shown), all on a common base-plate, horizontally mounted. Current transformers used with Size 1 overload relay blocks. Solid state overloads and special current transformers.
NOTE: Illustrations may not represent the actual enclosure; they are intended for dimensional information only. Dimensions are shown in inches.
E .50 13 E .50 13 D K
RESET RESET
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
A C
7.00 178
A F
B B I
M K
16-62
8-1/4 10-5/8
3-19/64 2-3/16
15-5/32 28-29/32 9-9/16 11-5/8 26-1/4 21-13/16 22-1/8 22-1/8 42-5/8 10-1/8 18-5/8 40 29-1/8
1-21/64 3-19/64 2-7/32 1-17/64 29/32 1-1/4 1-5/16 3-19/64 3-19/64 2-1/4 2-1/4 7/8 7/8
Size 3 (5-Pole3-Pole) with FA, KA breaker or 100 A disconnect switch. Size 4 (5-Pole3-Pole) with KA breaker or 200 A disconnect switch. Size 3 & 4 (3-Pole3-Pole) enclosures may be smaller. Consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733) for additional dimensional information.
NOTE: Illustrations may not represent the actual enclosure; they are intended for dimensional information only.
A D M K
HANDLE SWING L
HANDLE SWING C N O Y A F E H D B A F E H
HANDLE SWING D B
G C
G C
COVER OPEN 90
F W X W G J H I
16-63
16
Lighting Contactors
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
30 A fluorescent lighting rating, 20 A tungsten lighting rating Electrically and mechanically held 2 through 12-pole versions Field-convertible contacts with N.O. and N.C. indicators (8 N.C. contacts maximumd) Silver-Cadmium-Oxide double break contacts
Type L
Type LX
Type
$ Pricea
Electrically Heldd 860.00 LO20c 404.00 2 LG20c 446.00 LF20c 689.00 LH20c 860.00 LWW20c 1146.00 LW20c 917.00 LA20c 903.00 LO30c 446.00 3 LG30c 489.00 LF30c 732.00 LH30c 903.00 LWW30c 1197.00 LW30c 959.00 LA30c 1031.00 LO40c 575.00 4 LG40c 617.00 LF40c 860.00 LH40c 1031.00 LWW40c 1358.00 LW40c 1088.00 LA40c 6 LG60c 890.00 LF60c 1031.00 LH60c 1202.00 LWW60c 1571.00 LW60c 1259.00 LA60c 1202.00 LO60c 746.00 30c 8 LG80c 1160.00 LF80c 1301.00 LH80c 1472.00 LWW80c 1908.00 LW80c 1529.00 LA80c 1472.00 LO80c 1017.00 10 LG1000c 1331.00 LF1000c 1472.00 LH1000c 1643.00 LWW1000c 2123.00 LW1000c 1700.00 LA1000c 1643.00 LO1000c 1188.00 12 LG1200c 1529.00 LF1200c 1673.00 LH1200c 1844.00 LWW1200c 2372.00 LW1200c 1899.00 LA1200c 1844.00 LO1200c 1386.00 Mechanically Helde 2 LXG20c 702.00 LXF20c 975.00 LXWW20c 1728.00 LXW20c 1728.00 LXA20c 1017.00 LXO20c 590.00 3 LXG30c 738.00 LXF30c 1008.00 LXWW30c 1764.00 LXW30c 1764.00 LXA30c 1052.00 LXO30c 624.00 4 LXG40c 761.00 LXF40c 1031.00 LXWW40c 1785.00 LXW40c 1785.00 LXA40c 1074.00 LXO40c 647.00 30c 1044.00 6 LXG60c 1160.00 LXF60c 1430.00 LXWW60c 2186.00 LXW60c 2186.00 LXA60c 1472.00 LXO60c 1173.00 8 LXG80c 1287.00 LXF80c 1557.00 LXWW80c 2313.00 LXW80c 2313.00 LXA80c 1601.00 LXO80c 1314.00 10 LXG1000c 1430.00 LXF1000c 1700.00 LXWW1000c 2456.00 LXW1000c 2456.00 LXA1000c 1742.00 LXO1000c 12 LXG1200c 1580.00 LXF1200c 1850.00 LXWW1200c 2604.00 LXW1200c 2604.00 LXA1200c 1893.00 LXO1200c 1466.00 a Price does not include holding circuit contact. b Separate enclosures are available for these devices. It may be possible to improve delivery by ordering an open type contactor and separate Class 9991 enclosure. c Coil voltage code must be specified to order this product. Refer to standard voltage codes listed below. All lighting contactors are provided with separate control as standard. d Factory conversion of N.O. contacts to N.C., order by catalog number and add $42.80 to price (i.e. For 6 N.O. and 2 N.C. poles on an 8 pole contactor, order as 8903LG62V02). Versions are available from the factory with up to 12 N.C. poles electrically held or 2, 4, 6 and 12 N.C. poles mechanically held. For field conversion, there is a maximum of eight N.C. poles for Type L and a maximum of six N.C. poles for Type LX contactors. e Cannot support control transformer forms. f NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See page 16-104 for more information.
Table 16.176: Power Poles for Type L or LX The kits below are used to add 30 Ampere power poles to existing Type L contactors when additional circuits are required. Type L lighting contactors are supplied with mounting brackets, so that adder poles may be mounted from the front by a single captive screw. Adder poles are supplied standard with N.O. contacts which are convertible to N.C.
Power Pole Adder Kitg Class 8903 Type Single Pole L1L L1R Double Pole 86.00 86.00 $ Price Can Only Be Added to Contactor Typeh LO60 LXO60 LO80 LXO80 LO1000 LXO1000
g h
L3L 171.00 L3R 171.00 8903LO (electrically held) devices can accommodate 10 or 12 N.C. contacts use only 120 V 60Hz coils. LO60 & LXO60add 1-pole kits only, 1 on each side, for converting to 8-pole. To maintain proper operation, it cannot be converted to greater than 8-pole contactor. LO80 & LXO80use single-pole kits, 1 on each side, for converting to 10-pole and use two-pole kits, 1 on each side, for converting to 12-pole. LO1000 & LXO1000remove existing single pole kit and install two-pole kits, 1 on each side, for converting to 12-pole.
Type L3L
Type LO80
Type L3R
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Type L1L
Type LO60
Type L1R
16-64
CP1
Discount Schedule
Lighting Contactors
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
Features Electrically and mechanically held 30800 A lighting ratings 2- through 5-pole versions (5-poles through 200 A)
Contact Ampere Ratings NEMA 1 Flush Mounting General Purpose Enclosure with Plaster Adjustment Type $ Priceb
UL Listed short-circuit rating up to 100,000 Amperes Factory wired controls and clearly marked termination points Quick ship on most items in 57 days
Open Type
Type
$ Priceb
Electrically Heldc 2 SMG1d 476. SMF1d 660. SMH1d 647. SMW21d 989. SMW1d 989. SMA1d 647. SMO1de 446. 518. SMF2d 689. SMH2d 689. SMW22d 1031. SMW2d 1031. SMA2d 810. SMO2de 488. 30 3 SMG2d 4 SMG3d 633. SMF3d 818. SMH3d 804. SMW23d 1146. SMW3d 1146. SMA3d 804. SMO3de 603. 5 SMG4d 831. SMF4d 1017. SMH4d 1002. SMW24d 1344. SMW4d 1344. SMA4d 1002. SMO4de 534. 2 SPG1d 975. SPF1d 1215. SPH1d 1287. SPW21d 1998. SPW1d 1998. SPA1d 1287. SPO1de 831. 1031. SPF2d 1272. SPH2d 1344. SPW22d 2057. SPW2d 2057. SPA2d 1344. SPO2de 890. 60 3 SPG2d 4 SPG3d 1287. SPF3d 1529. SPH3d 1601. SPW23d 2712. SPW3d 2712. SPA3d 1601. SPO3de 1146. 5 SPG4d 1857. SPF4d 2100. SPH4d 2142. SPW24d 3281. SPW4d 3281. SPA4d 2142. SPO4de 1715. 2 SQG1d 1601. SQF1d 2015. SQH1d 1971. SQW21d 3815. SQW1d 3054. SQA1d 1971. SQO1de 1314. 1715. SQF2d 2127. SQH2d 2084. SQW22d 3959. SQW2d 3167. SQA2d 2084. SQO2de 1430. 100 3 SQG2d 4 SQG3d 2114. SQH3d 2484. SQW3d 3965. SQA3d 2484. SQO3de 1827. 5 SQG4d 3024. SQH4d 3396. SQW4d 4877. SQA4d 3396. SQO4de 2739. 6245. SVA1d 4991. SVO1d 3167. 2 SVG1d 3765. SVH1d 4991. SVW1d 6501. SVA2d 5247. SVO2d 3423. 4022. SVH2d 5247. SVW2d 200 3 SVG2d 8864. SVA3d 7011. SVO3d 4761. 4 SVG3d 5285. SVW3d Electrically Held 10646. SVA4d 8793. SVO4d 6543. 5 SVG4d 7127. SVW4d 7952. SXW1d 11087. SXA1d 11087. SXO1d 6857. 300 2 SXG1d 3 SXG2d 8550. SXW2d 11685. SXA2d 11685. SXO2d 7455. 2 SYG1d 20813. SYW1d 27935. SYA1d 24659. SYO1d 16299. 400g 3 SYG2d 23534. SYW2d 30654. SYA2d 27378. SYO2d 19020. 25550. SZW1d 32670. SZA1d 29394. SZO1d 20879. 600g 2 SZG1d 3 SZG2d 28704. SZW2d 35825. SZA2d 32549. SZO2d 24026. 2 SJG1d 30285. SJW1d 37535. SJA1d 33845. SJO1d 25457. 800g 3 SJG2d 33875. SJW2d 40995. SJA2d 37719. SJO2d 29033. Mechanically Heldc 2 SMG10d 738. SMF10d 923. SMW31d 1251. SMW10d 1251. SMA10d 912. SMO10de 710. 782. SMF11d 966. SMW32d 1295. SMW11d 1295. SMA11d 953. SMO11de 752. 30 3 SMG11d 4 SMG12d 824. SMF12d 1008. SMW33d 1337. SMW12d 1337. SMA12d 995. SMO12de 795. 5 SMG13d 1025. SMF13d 1209. SMW34d 1538. SMW13d 1538. SMA13d 1196. SMO13de 995. 2 SPG10d 1485. SPF10d 1758. SPW31d 2511. SPW10d 2511. SPA10d 1800. SPO10de 1373. 3 SPG11d 1544. SPF11d 1814. SPW32d 2570. SPW11d 2570. SPA11d 1857. SPO11de 1430. Mechanically Held 60 4 SPG12d 1827. SPF12d 2100. SPW33d 3252. SPW12d 3252. SPA12d 2142. SPO12de 1715. 5 SPG13d 2399. SPF13d 2669. SPW34d 3824. SPW13d 3824. SPA13d 2712. SPO13de 2285. 2 SQG10d 2084. SQF10d 2241. SQW31d 4419. SQW10d 3537. SQA10d 2456. SQO10de 1827. 2199. SQF11d 2357. SQW32d 4563. SQW11d 3653. SQA11d 2570. SQO11de 1943. 100 3 SQG11d 4 SQG12d 2627. SQW12d 4478. SQA12d 2996. SQO12de 2370. 5 SQG13d 3537. SQW13d 5390. SQA13d 3909. SQO13de 3281. 2 SVG10d 5333. SVW10d 7811. SVA10d 6557. SVO10d 4505. 200 3 SVG11d 6015. SVW11d 8495. SVA11d 7241. SVO11d 4877. 4 SVG12d 7353. SVW12d 10859. SVA12d 9008. SVO12d 6215. 9320. SXW13d 12455. SXA13d 12455. SXO13d 7554. 300 2 SXG13d 10232. 3 SXG14d SXW14d 13365. SXA14d 13365. SXO14d 7811. 2 SYG16d 22593. SYW16d 29714. SYA16d 26441. SYO16d 18080. 400 3 SYG17d 25316. File E78427 SYW17d 32436. SYA17d 29160. SYO17d 20799. CCN NRNT SZW18d 34451. SZA18d 31175. SZO18d 22658. 600 2 SZG18d 27329. 3 SZG19d 30483. SZW19d 37605. SZA19d 34329. SZO19d 25806. a NEMA 4 & 4X enclosures are brush finished stainless steel for contactors sized 30 A through 300 A. Sizes 400800 A are painted sheet steel. b Price does not include holding circuit contact. File LR60905 c All lighting contactors are provided with separate control as standard, except electrically held 400, 600 and 800 A devices. Electrically held 400, 600 and (Open Devices Only) 800 A devices are provided with common control. d Voltage code must be specified to order this product. Refer to standard voltage codes above left. Class 3231 01 e Separate enclosures are available for these devices. It may be possible to improve delivery by ordering an open type contactor and separate Class 9991 enclosure from pages 16-102 and 16-103. f Cannot support control transformer forms. g Form F4T is provided as standard; include line voltage when ordering. Control voltage is 12060. For 400, 600 and 800 ampere devicesmust specify line voltage, not coil voltage. h NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See page 16-104 for more information.
One N.O. SB6 158.00 One N.C. SB7 158.00 30 One N.O. and One N.C. SB8 365.00 Two N.O. SB9 365.00 Two N.C. SB10 365.00 One N.O. SB21j 306.00 One N.C. SB22j 306.00 60 One N.O. and One N.C. SB23j 656.00 Two N.O. SB24j 656.00 Two N.C. SB25j 656.00 j When power pole is added to 60 Ampere contactor, a 4-pole coil is also required. Order from Coil Table page 16-114. 60 A power poles are suitable for use with copper or aluminum wire. Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-69 Replacement Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-114, 16-115 Replacement Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 16-116
CP1
Discount Schedule
16-65
16
A single-pole or double-pole kit can be added to any 2- or 3-pole 30 or 60 A Type S lighting contactor to make a 4- or 5-pole device. Factory assembled 4- and 5-pole contactors utilize the basic 3-pole device with a single or double-pole kit installed. Only one power pole can be added per contactor. Sufficient room is provided in all enclosure styles for the addition of a power pole kit.
Table 16.181:
The features include: disconnect switch and circuit breaker versions; rugged flange-mounted handle; easy installation; occupation of less space; increased operator protection; room to spare for modifications; Class R fuse clips standard; electrically and mechanically held; 30600 Amperes. It is desirable to install the branch-circuit protective device and lighting contactor, combining switching and over-current protection, in one enclosure. Combination lighting contactors are well suited for industrial, highway and area lighting applications, or where a lighting circuit may have to be disconnected for periodic maintenance. They may also be used for resistance heating loads. Table 16.182: Fusible or Non-Fusible Disconnect Switch (3-Pole, 5060 Hz)
Contactor Ampere Rating Fuse Clip Size (A) Fuse Clip Spacing (V) NEMA 1 General Purpose Enclosure Type SMG60d SMG61d SMG62d SPG60d SPG61d SPG62d SQG60d SQG61d SQG62d SVG60d SVG61d SVG62d SXG60d SXG61d SXG62d SMG70d SMG71d SMG72d SPG70d SPG71d SPG72d SQG70d SQG71d SQG72d SVG70d SVG71d SVG72d SXG70d SXG71d SXG72d $ Pricea 1301.00 1373.00 1344.00 2042.00 2142.00 2100.00 3396.00 3609.00 3537.00 6629.00 6926.00 6870.00 13905.00 14418.00 14418.00 1458.00 1529.00 1502.00 2583.00 2682.00 2640.00 3909.00 4121.00 4050.00 8081.00 8379.00 8324.00 14261.00 14774.00 14774.00 NEMA 4 & 4X b Watertight and Dusttight Enclosure Stainless Steel Type SMW60d SMW61d SMW62d SPW60d SPW61d SPW62d SQW60d SQW61d SQW62d SVW60d SVW61d SVW62d SXW60d SXW61d SXW62d SMW70d SMW71d SMW72d SPW70d SPW71d SPW72d SQW70d SQW71d SQW72d SVW70d SVW71d SVW72d SXW70d SXW71d SXW72d $ Pricea 2669.00 2739.00 2712.00 4149.00 4248.00 4206.00 7070.00 7284.00 7212.00 11327.00 11627.00 11570.00 25898.00 26411.00 26411.00 2825.00 2897.00 2867.00 4692.00 4791.00 4748.00 7583.00 7797.00 7725.00 12780.00 13080.00 13023.00 26253.00 26766.00 26766.00 NEMA 12/3Re Dusttight, Oiltight Driptight, Industrial Use Enclosure Type SMA60d SMA61d SMA62d SPA60d SPA61d SPA62d SQA60d SQA61d SQA62d SVA60d SVA61d SVA62d SXA60d SXA61d SXA62d SMA70d SMA71d SMA72d SPA70d SPA71d SPA72d SQA70d SQA71d SQA72d SVA70d SVA71d SVA72d SXA70d SXA71d SXA72d $ Pricea 1643.00 1715.00 1686.00 2528.00 2627.00 2583.00 4022.00 4235.00 4163.00 8366.00 8585.00 8607.00 18122.00 18635.00 18635.00 1800.00 1871.00 1844.00 3068.00 3167.00 3123.00 4535.00 4748.00 4676.00 9818.00 10116.00 10061.00 18477.00 18990.00 18990.00
Electrically Heldc None 30 30 30 None 60 60 60 None 100 100 100 None 200 200 200 None 300 400 400 Mechanically Heldc None 30 30 30 None 60 60 60 None 100 100 100 None 200 200 200 None 300 400 400
600 250 600 250 600 250 600 250 600 250 600 250 600 250 600 250 600 250 600 250
Ampere Rating
Maximum Volts
Electrically Heldc 30 30 600 SMG81d 1814.00 SMW81d 3182.00 SMA81d 2156.00 60 60 600 SPG81d 2541.00 SPW81d 4649.00 SPA81d 3024.00 100 100 600 SQG81d 3666.00 SQW81d 7340.00 SQA81d 4292.00 200 200 600 SVG81d 8181.00 SVW81d 12879.00 SVA81d 9918.00 300 300 600 SXG81d 18023.00 SXW81d 30014.00 SXA81d 21155.00 400 400 600 SYG81d 40085.00 SYW81d 47205.00 SYA81d 43929.00 600 600 600 SZG81d 45090.00 SZW81d 52212.00 SZA81d 48936.00 Mechanically Heldc 3338.00 SMA91d 2313.00 30 30 600 SMG91d 1971.00 SMW91d 60 60 600 SPG91d 3081.00 SPW91d 5189.00 SPA91d 3567.00 100 100 600 SQG91d 4179.00 SQW91d 7853.00 SQA91d 4805.00 200 200 600 SVG91d 9633.00 SVW91d 14333.00 SVA91d 11970.00 300 300 600 SXG91d 18378.00 SXW91d 30371.00 SXA91d 21510.00 400 400 600 SYG91d 41864.00 SYW91d 48986.00 SYA91d 45710.00 600 600 600 SZG91d 46728.00 SZW91d 53991.00 SZA91d 50715.00 a Price does not include holding circuit contact. b For NEMA 4 & 4X Watertight, Dusttight and Corrosion-Resistant Glass-Polyester enclosure pricing, multiply stainless steel enclosed price by 1.25 and add Form G18 (limited to 100 A max.). 400 & 600 A enclosures are painted sheet steel (NEMA Type 4 & 4X). c Control/coil voltage must be specified. d Coil voltage codes must be specified to order this product. Refer to standard voltage codes shown on page 16-65. e NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See page 16-104 for more information.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-66
CP1
Discount Schedule
Lighting Contactors
www.schneider-electric.us
NIGHT-MASTER Outdoor Combination Lighting Contactors offer disconnecting means, overcurrent protection and a lighting contactor in one NEMA 3R Rainproof enclosure. These combination units satisfy requirements of the National Electrical Code and UL 508 for service entrance equipment.
Features:
Solid neutral standard Grounding lug standard Padlocking provisions Short and long versions available Electrically held Type S lighting contactor Eliminates the need for separate mounted safety switches Additional panel space eliminates the need for external mounting of time clocks
Long Version
Short Version
Ampere Rating
Maximum Volts
30 30 600 SMC81c 2475.00 4050.00 SMC83c 60 60 600 SPC81c 3159.00 5175.00 SPC83c 100 100 600 SQC81c 4544.00 7425.00 SQC83c 200 200 600 SVC81c 8711.00 14175.00 SVC83c a Price does not include holding circuit contact. b All lighting contactors are provided with separate control as standard. c Coil voltage codes must be specified to order this product. Refer to standard voltage codes listed below.
24 volt coils are not available for 200 A devices. Contact your nearest Square D/Schneider Electric sales office for additional information.
CP1
Discount Schedule
16-67
16
Panelboard Lighting Contactors, sometimes called remote control switches, are designed for use with lighting panelboards and motor control centers where either panel or bus mounting is desirable. Type PB lighting contactors can be used in a retrofit or new project without increasing the panelboard depth. They can be used to directly replace many inoperative existing switches. Table 16.188: Class 8903 Type PB Lighting Contactors
Description Size (A) Bus Mount
The features include: mechanically held; compatible with Square D panelboards; short-circuit ratings to 100 kA; compact arc suppression; bus or panel mounted; fits in standard-depth lighting panelboards; easy manual operation; standard coil clearing contacts; and operates in any position.
Panel Mount (Includes Lugs) $ Price 2129.00 2403.00 2237.00 2573.00 2237.00 2573.00 2541.00 2978.00 3162.00 4055.00 3551.00 4496.00 3909.00 4958.00 Type PBM 10a PBM 11a PBP 10a PBP 11a PBN 10a PBN 11a PBQ 10a PBQ 11a PBR 10a PBR 11a PBV 10a PBV 11a PBW 10a PBW 11a $ Price 2640.00 2973.00 2762.00 3185.00 2762.00 3185.00 3119.00 3546.00 3897.00 4787.00 4409.00 5360.00 4964.00 5990.00
Panel Mount
Poles Type 2 PBM 10Ba 30 3 PBM 11Ba 2 PBP 10Ba 60 3 PBP 11Ba 2 PBN 10Ba 75 3 PBN 11Ba 2 PBQ 10Ba 100 3 PBQ 11Ba 2 PBR 10Ba 150 3 PBR 11Ba 2 PBV 10Ba 200 3 PBV 11Ba 2 PBW 10Ba 225 3 PBW 11Ba Voltage code must be specified to order this product. Refer to standard voltage codes listed below.
IN mm IN mm IN mm IN mm IN mm IN mm IN mm 30 11.75 298 7.50 191 3.88 98 2.25 57 7.38 187 2.25 57 9.25 235 100 150 14.50 368 7.50 191 3.88 98 2.88 73 8.50 216 3.00 76 10.50 267 225
B H
H E B
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
C W
16-68
CP1
Discount Schedule
Lighting Contactors
www.schneider-electric.us
Modifications (Forms)
Class 8903 / Refer to Catalog 8903CT9701R8/08
Table 16.197:
Description Form Letter A3 A3 A12 C NIGHTElec. Mech. Elec. Mech. MASTER a Held Held Held Held 1 Y Y 3R, 4, 12 Y Y Any Y Y Y 1 Y Yj Y Yj NEMA Enclosure Type Used On Std. Combo Type L 30 Amp 336. 336. 336. 336. 30 Amp 336. 336. 336. 336. 60 Amp 336. 336. 336. 336. 100 Amp 336. 336. 336. 336. 200 Amp 336. 336. 336. 336. 300 Amp 336. 336. 336. 336. 400 600 800 Amp 336. 336. 336. 336.
Voltage 60 Hz 12024 208120 24024 240120 277120 48024 480120 480240 600120
Code V89 V84 V82 V80 V85 V83 V81 V87 V86
Order Example
You have previously selected a Class 8903SMG2V02.
V02 means that you need a coil voltage of 120-60/110-50 wired for separate control. You would like to add form FF4T with the transformer voltages being 480 volt primary, 120 volt secondary. The new and complete Class, Type, Voltage Code and Form number: Class 8903 k Type SMG2 Voltage Code V81 Formk FF4T
CP1
Discount Schedule
16-69
16
ON-OFF push button (with holding circuit interlock) HANDOFFAUTO selector switch. To substitute a key operated selector switch, use Form C33 and specify positions, legend marking, and key removal. This form must be used with another selector switch C 3R, 4, 12 Y Yj Y Yj Y 336. 336. 336. 336. 336. 336. 336. form (example: CC33). Add $266. (C33) + $224. (C) = $490. ON-OFF selector switch. To substitute a key operated C6 1 Y Y Y Y 336. 336. 336. 336. 336. 336. 336. selector switch, use Form C33 and specify positions, legend marking, and key removal. This form must be C6 3R, 4, 12 Y Y Y Y Y 336. 336. 336. 336. 336. 336. 336. used with another selector switch form (example: C33C6). Add $266. (C33) + $224. (C6) = $490. Control circuit fuse (1 fuse) F Any Y Y Y Y Y 314. 314. 314. 314. 314. 314. 314. Control circuit fuses (2 fuses) F4 Any Y Y Y Y Y 314. 314. 314. 314. 314. 314. 314. Control circuit transformer standard capacity 50/60 Hz Fuses Transformer capacity Primary Secondary 2b 0 Std. F4T 1, 4, 12 Y Y Y Y Y 386. 386. 543. 797. 968. 1097. i 1097. c 2 1 Std. FF4T 1, 4, 12 Y Y Y Y Y 698. 698. 855. 1112. 1283. 1412. i 1412. c 2 1 100 VA Add. FF4T11 1, 4, 12 Y Y Y Y Y 975. 975. 1197. 1425. 1566. i 1710. i 1710. c 2 1 200 VA Add FF4T12 1, 4, 12 Y Y Y Y Y 1241. 1241. 1467. 1695. i 1839. i 1839. i 1839. c 2 1 300 VA Add FF4T13 1, 4, 12 Y Y Y Y Y 1481. i 1481. i 1737. i 1967. i 2109. i 2109. i 2109. c Noise reduced enclosure and shock mounted panel G4 Any Y 1389. 1389. 1596. 1674. 2307. 2921. 3924. Addition of photoelectric receptacle G10 1d, 3R, 12 Y Y Y 185. 185. 185. 185. 185. 185. 185. Addition of photoelectric receptacle with photo-cell G101 1d, 3R, 12 Y Y Y 399. 399. 399. 399. 399. 399. 399. Addition of photoelectric receptacle and relay (R6)e G10R6 1d, 12 Y Y 549. 912. 912. 912. 1326. 1467. 1467. With photo-cell installed e G101R6 1d, 12 Y Y 509. 750. 750. 750. 1026. 1121. 1121. Addition of terminal blocks (other than standard). xx Represents the number of terminals needed. Available in multiples of 5 only. (PER TERMINAL PRICE) WIRED G56xx Any Y Y Y Y Y 116. 116. 116. 116. 116. 116. 116. (PER TERMINAL PRICE) UNWIRED G50xx Any Y Y Y Y Y 57. 57. 57. 57. 57. 57. 57. Addition of 24 hour time clock (120-277 V only) K14 1, 4, 12 Y Y Y Y 1197. 1197. 1197. 1197. 1197. 1197. 1197. Addition of 24 hour time clock w/day omission (120-277 V) K141 1, 4, 12 Y Y Y Y 1197. 1197. 1197. 1197. 1197. 1197. 1197. Addition of 7 day time clock (120-277 V) K142 1, 4, 12 Y Y Y Y 1368. 1368. 1368. 1368. 1368. 1368. 1368. Addition of 24 hour time clock (120-277 V only) K14 3R Y N/A 783. 783. 783. 783. N/A N/A Addition of 24 hr time clock w/skip day (120-277 V) K141 3R Y N/A 783. 783. 783. 783. N/A N/A Addition of 7 day time clock (120-277 V) K142 3R Y N/A 954. 954. 954. 954. N/A N/A Addition of solid neutral terminal block N 1, 4, 12 Y Y Y Y Std. 116. 116. 116. 171. 342. 714. 855. Red Pilot Light P1 Any Y Y Y Y Y 336. 336. 336. 336. 336. 336. 336. Two or more lights f (each) P Any Y Y Y Y Y 336. 336. 336. 336. 336. 336. 336. Red Push-To-Test Pilot Light P21 Any Y Y Y Y Y 435. 435. 435. 435. 435. 435. 435. Interlock necessary for pilot light g Any Y Y Y Y Y h 158. 158. 158. 158. 158. 158. one needed for each additional pilot light Two Wire Interface for Mechanically Held e R6 Any Y Y 363. 728. 728. 728. 1139. 1283. 1283. Addition of under and overvoltage relay R46 Any Y Y Y Y Y 1463. 1463. 1463. 1463. 1463. 1463. 1463. Three wire control for long distance applicationse R62 Any Y Y 728. 1454. 1454. 1454. 2280. 2564. 2564. Auxiliary contacts (specify number of N.O. + N.C.) X Any Y Y Y Y Y h 158. 158. 158. 158. 158. 158. Addition of DC coil to Type L (7 poles max) Y48 Any Y 243. N/A N/A N/A N/A N/A N/A Auxiliary electrical interlock installed on disconnect switch Y74 Any Y Y Y N/A 158. 158. 158. 158. 414. 414. or circuit breaker operating mechanism Coil Transient suppressor (120 Vac Only) Y145 Any Y Y Y 158. 158. 158. 158. 158. 158. N/A Coil Transient suppressor (120 Vac Only) Y145 Any Y Y 314. 314. 314. 314. 314. 314. 314. Addition of lightning arrestor Y1532 Any Y Y Y Y Y 570. 570. 570. 570. 570. 570. 570. Substitute copper only lugs for standard Y157 Any Y Y Y Y Y N/A N/A N/C N/C N/C N/C N/C a NIGHT-MASTER maximum 200 A, minimum 30 A. b Transformer Voltage Codes. c Mechanically held only. Electrically held device has a control circuit requiring a 120 V secondary, therefore, a transformer is supplied. The transformer comes wired to L1 and L2 unless Form S is called for. It is supplied with two primary and one secondary fuse. d Photocell mounted on a NEMA 1 enclosure is designed for indoor areas which rely on natural light. Addition of the photocell does not make the enclosure suitable for outdoor (NEMA Type 3R) installations. e Available for 24 V, 120 V, 240 V, 277 V and 480 V applications only. f For electrically held enclosed devices, the first pilot is wired in parallel with the coil. Operating interlocks are required for all additional pilot lights. Mechanically held devices require operating interlocks for all pilot lights. g DO NOT use Form X for any interlock which is wired in series with pilot light, but DO specify how pilot light and interlock are to be wired into the circuit. h Electrically held 20 A multipole contactors cannot add interlocks. Additional poles can be used for the same function, however. Mechanically held (Type LX) provide one double throw auxiliary (or status) contact as standard. i Single primary voltage must be specified using the codes shown below: j Form R6 must be used with Form C on mechanically held devices.
Lighting Contactors
Field Modifications
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
Table 16.198:
Types L & LX Description 30 Amp Kit Auxiliary Contacts 1 N.O. LH or RH Mounting 1 N.C. LH or RH Mounting 1 N.C. & 1 N.O. Isolated LH or RH 1 N.O. Overlapping LH or RH 1 N.C. Overlapping LH or RH Control Circuit Fuse Holder Single Fuse Unit Two Fuse Unit 9999LLX and 9999SFR3 9999LLX and 9999SFR4 $ Price 30 Amp Kit $ Price 60 Amp Kit $ Price 86.00 86.00 116.00 116.00 116.00 100 Amp Kit 9999SX6 9999SX7 9999SX8 9999SX9 9999SX10 $ Price 86.00 86.00 116.00 116.00 116.00 Type S 200 Amp Kit 9999SX6 9999SX7 9999SX8 9999SX9 9999SX10 $ Price 86.00 86.00 116.00 116.00 116.00 300 Amp Kit 9999SX6 9999SX7 9999SX8 9999SX9 9999SX10 $ Price 86.00 86.00 116.00 116.00 116.00 400, 600, 800 Amp Kit 9999SX6 9999SX7 9999SX8 9999SX9 9999SX10 $ Form Price No. 86.00 86.00 116.00 116.00 116.00
9999SX6 9999SX7 9999SX8 9999SX9 9999SX10 23.70 9999SFR3 42.80 23.70 9999SFR4 57.00 9070T100
86.00 9999SX6 86.00 9999SX7 116.00 9999SX8 116.00 9999SX9 116.00 9999SX10
64.00 86.00
64.00 86.00
64.00 86.00
64.00 86.00
64.00 86.00
F F4 T
Transformers (For Prices 9070T50 See Class 9070 Section) Oversized Enclosures (Non-Combo) NEMA 1 9991SDG3 266.00 NEMA 4 9991SDW3 779.00 NEMA 12 9991SDA3 456.00 Standard Enclosures NEMA 1Surface Mount 9991LXG1 95.00 NEMA 3R 9991SDH1 323.00 NEMA 4Standard 9991SDW1 779.00 NEMA 4With 2 Cvr Mtd. Clsng 9991SDW11 798.00 Plts 9991SDW20 779.00 NEMA 4XGlass Polyester 9991SDA11 323.00 NEMA 12 NEMA 1FlushmountComplete NEMA 1Flush Mount Parts FLUSH PARTS 9991SDF13 114.00 StandardElec. held 9991SDF13 114.00 StandardMech. held 9991SDF2 66.00 Mounting Strap 9991SDF1 77.00 Pull Box
9991SDG3 339.00 9991SDG3 339.00 9991SDW3 1169.00 9991SDW3 1169.00 9991SDA3 684.00 9991SDA3 684.00
9991SCG7a 9991SCH2 9991SCW1 9991SCW11 9991SCW20 9991SCA11 9991SCF11 9991SCF13 9991SCF2 9991SCF1
57.00 372.00 684.00 714.00 684.00 372.00 57.00 201.00 71.00 86.00
9991SDG7a 143.00 9991SFG8 599.00 9991SDH1 485.00 9991SEH1 684.00 9991SDW1 1169.00 9991SDW11 1197.00 9991SEW11 1767.00 9991SDW20 1169.00 9991SDA11 485.00 9991SEA11 684.00 9991SEF11 882.00 9991SDF11 171.00 9991SDF13 171.00 9991SDF2 99.00 9991SDF1 116.00
9991SFG4 9991SFH1
1259.00 1853.00
9991SGG8 1241.00
Internal Operator 3010215901 26.10 3010215901 39.20 3010215901 39.20 3010215901 39.20 3010215901 39.20 3010215901 39.20 3010215901 39.20 G53 Mounting Bracket Solid Neutral 9999SN1 89.00 9999SN1 134.00 9999SN1 134.00 9999SN1 134.00 9999SN2 392.00 9999SN2 392.00 9999SN3b 624.00 N Combination Lighting Contactor Disconnect Interlock Kit Breaker Type 1-Pole 9999R26 131.00 9999R26 131.00 9999R26 131.00 9999R26 131.00 9999R26 131.00 9999R26 131.00 2-Pole 9999R27 243.00 9999R27 243.00 9999R27 243.00 9999R27 243.00 9999R27 243.00 9999R27 243.00 Disconnect Type 1-Pole 9999TC11 120.00 9999TC10 116.00 9999TC10 120.00 9999R8 131.00 9999R35 435.00 9999R26 131.00 2-Pole 9999TC21 239.00 9999TC20 221.00 9999TC20 239.00 9999R9 243.00 9999R36 521.00 9999R27 243.00 Y74 Lightning Arrestor 175 Vac to Ground Max SDSA1175 92.00 SDSA1175 92.00 SDSA1175 92.00 SDSA1175 92.00 SDSA1175 92.00 SDSA1175 92.00 SDSA1175 92.00 2 or 3 wire Grounded Y1532 650 Vac to Ground Max SDSA3650 248.00 SDSA3650 248.00 SDSA3650 248.00 SDSA3650 248.00 SDSA3650 248.00 SDSA3650 248.00 SDSA3650 248.00 3 or 4 wire Grounded VERSA CRIMP Lugs (Price Ea.) c Range #81/0 Al/Cu VCEL02114S1 7.70 #12/0 Al/Cu VCEL022516H1 12.20 2/04/0 Al/Cu VCEL024516H1 16.10 4300 kcmil Al/Cu VCEL030516H1 49.10 2/0500 kcmil Al/Cu VCEL05012H1 64.00 400600 kcmil Al VCEL06012H1 44.60 400500 kcmil Cu VCEL06012H1 44.60 500750 kcmil Al VCEL07512H1 58.00 500 kcmil Cu VCEL07512H1 58.00 400600 kcmil Al VCEL06012H2d 47.70 400500 kcmil Cu VCEL06012H2d 47.70 500750 kcmil Al VCEL07512H2d 48.20 500 kcmil Cu VCEL07512H2d 48.20 Hardware 2-Polec 9999AL13 143.00 Hardware 3-Pole Not Needed 9999AL14 179.00 9999AL11 53.40 9999AL12 116.00 Hardware 4-Pole 9999AL15 215.00 9999AL11 53.40 9999AL12 116.00 a For electrically held only. b Limited to 400 and 600 A versions. 800 A is a factory modification only. c VERSA CRIMP Lug prices subject to change. 9999AL hardware kit is also required. Two 1-pole kits required. d One or two lugs may be mounted on each terminal. Limited to 400 and 600 A versions. 800 A is factory modification only.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-70
CP1
Discount Schedule
Lighting Contactors
www.schneider-electric.us
Field Modifications
Class 8903 / Refer to Catalog 8903CT9701R8/08
A3
C6
35.60 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 116.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1
9999BLX 9999SC2
35.60 116.00
9001KN260 4.40 9001KN260 4.40 9001KN260 4.40 9001KN260 4.40 9001KN260 4.40 9001KN260 4.40 9001KS46BH2 138.00 9001KS46BH2 138.00 9001KS46BH2 138.00 9001KS46BH2 138.00 9001KS46BH2 138.00 9001KS46BH2 138.00
9001KN260 4.40 9001KS46BH2 138.00 R6 9999RLX CA2SK11g 35.60 95.00 8501XO11 201.00 8501XO11 201.00 8501XO11 201.00 8501XO11 201.00 8501XO11 201.00 8501XO11 201.00
Kit $ Price Kit $ Price Kit $ Price Kit $ Price Kit $ Price Kit $ Price Kit $ Price PILOT LIGHTS (RED and GREEN) c d d NEMA 1 Enclosure P1 9999SP28R 215.00 9999SP2R 215.00 9999SP3R 215.00 9999SP14R 215.00 9999SP28R 215.00 9999SP28R 215.00 9999SP28R 215.00 NEMA 3R, 4 or 12 9999SP28R 215.00 9999SP28R 215.00 9999SP28R 215.00 9999SP28R 215.00 9999SP28R 215.00 9999SP28R 215.00 Enclosure PUSH BUTTONSe 9999BLX 35.60 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 NEMA 1 Enclosure 9999SA10 116.00 9999SA10 116.00 9999SA10 116.00 A12 NEMA 3R, 4 or 12 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 9999SA3 215.00 Enclosure SELECTOR SWITCH 9999BLX 35.60 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 (2 POSITION) 9999SC22 116.00 9999SC22 116.00 9999SC22 116.00 9999SC22 116.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 NEMA 1 Enclosure C6 NEMA 3R, 4 or 12 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 9001KN244 4.40 Enclosure 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BM1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 9001KS11BH1 96.00 SELECTOR SWITCH 9999BLX 35.60 (3 POSITION) 9999SC2 116.00 9999SC2 116.00 9999SC2 116.00 9999SC8 215.00 9999SC8 215.00 9999SC8 215.00 9999SC2 116.00 NEMA 1 Enclosure C NEMA 3R, 4 or 12 9999SC8 215.00 9999SC8 215.00 9999SC8 215.00 9999SC8 215.00 9999SC8 215.00 9999SC8 215.00 9999SC8 215.00 Enclosure a No field installed kit available. b Mechanically held contactors need two distinct signals to operate. An N.O. contact block must be added to the Class 9999 Type SA3 push button kit. c Selection for 2- or 3-Pole only; for 4- or 5-Pole use Class 9999SP15R $215. d The coil voltage must be the same as the pilot light rating. Kit contains one (1) Class 9001, Type KP1R6 120 V/60 Hz red pilot light control unit. For other voltages, refer to the Class 9001, Type KP Control Section. e Requires holding circuit interlock for Type S or additional power pole on Type L devices. f Form R6 available for 24 V, 120 V, 240 V and 277 V only. g Insert CA2SK11( ) voltage code from page 23-20.
CP1
Discount Schedule
16-71
16
Lighting Contactors
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
Approximate Dimensions
Table 16.201: Open Type
Electrically Held Ampere Rating Type Number of Poles 24 30 LO 6 812 23 30 SMO 45 23 60 SPO 45 23 100 SQO 45 23 200 SVO 4 & 5a 300 400 600 800 a SXO SYO SZO SJO 23 23 23 Dimensions A 2.88 73 4.25 108 5.63 143 4.34 110 4.34 110 5.33 135 6.22 158 7.09 180 7.82 199 9.14 232 9.14 232 12.31 313 B 5 127 5 127 5 127 3.22 82 4.25 108 4.31 110 5.61 142 5.45 138 9.75 248 6.00 152 9.75 248 8.66 220 12.33 313 12.33 313 C 4.62 117 4.62 117 4.62 117 4.22 107 4.22 107 4.94 125 4.94 125 6.50 165 6.50 165 6.50 165 6.50 165 8.74 222 9.00 229 11.94 303 E 3.12 79 3.12 79 3.12 79 3.50 89 3.50 89 5.50 140 5.50 140 7.26 184 7.26 184 9.14 232 9.14 232 12.25 311 27.78 706 42.70 1085 Type A 2.88 73 4.25 108 5.63 143 7.15 182 7.15 182 8.25 210 8.70 221 10.13 257 10.56 268 11.35 288 11.55 293 12.31 313 Mechanically Held Dimensions B 3.79 96 4.54 115 4.61 117 5.90 150 5.94 151 9.75 248 6.00 152 9.75 248 8.66 220 8.66 220 C 4.68 119 4.68 119 5.23 133 5.23 133 6.72 171 6.72 171 6.72 171 6.72 171 10.50 267 10.50 267 D 8.81 224 8.81 224 8.81 224 E 3.25 83 3.25 83 3.25 83 6.04 153 6.04 153 7.81 198 7.81 198 7.26 184 7.26 184 9.14 232 9.14 232 12.31 313 21.00 533 F 7.70 196 7.70 196 7.70 196
B D
LXO
F Mtg.
SVO
A E
Open Type S
30
LG, LXG
Any
30
30
SMG
25
25 60 SPG 25 25
30
30
SMF
2&3
24.00 610
17.50 445
15.00 381
19.25 489
5.75 146
100
SQG
15.19 386
8.94 227
7.63 194
12.88 327
4&5
60
SPF
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
200 300 400 and 600 800 b SVG SXG SYG & SZG SJG
100
SQF
Enclosure
Saddle
16-72
Lighting Contactors
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
Approximate Dimensions
Table 16.204: NEMA 3R
Ampere Rating 30 30 60 100 Type Number of Poles All A 8.83 224 9.83 250 12.83 326 12.83 326 B 12.30 312 16.30 414 25.30 643 40.30 1024 C 7.12 181 8.62 219 8.62 219 9.12 232 D1 1.39 35 1.39 35 1.39 35 1.39 35 D2 1.44 37 1.44 37 1.44 37 1.44 37 E 6.00 152 7.00 178 10.00 254 10.00 254 F 7.50 191 11.50 292 20.50 521 35.50 902 G1 2.64 67 2.64 67 2.64 67 2.64 67 G2 2.16 55 2.16 55 2.16 55 2.16 55 H1 2.08 53 2.08 53 2.08 53 2.08 53 H2 2.62 66 2.62 66 2.62 66 2.62 66 J 14.28 363 16.78 426 19.78 502 20.28 515 K 1.37 35 1.31 33 1.31 33 1.31 33 L 1.37 35 1.75 44 1.94 49 2.31 59 M 1.88 48 2.13 54 2.44 62 2.69 68 N 4.38 111 4.88 124 6.38 162 6.38 162 P 1.83 46 1.83 46 1.83 46 1.83 46 K.O. X 1/2 3/4 1 1 1 1/4 1 1/2 1 1 1/4 2 2 1/2 1 1 1/4 2 2 1/2 K.O. Y 1/2 3/4 1 1/2 3/4 1/2 3/4 1/2 3/4
All
All
200
SVH
All
30
LW LXW
Standard, F, R6, Y48 Any A3, A12, C, C6, P T , Electrically Held Mechanically Held Std., A12, C, C6, P X , Std., F, X T N, R6 A3, C, C6, T, N, P, R6 Std., A12, C, C6, P X , Std., A3, C, C6, P, X T, N, R6 A3, C, C6, T, N, P, R6 Std., A12, C, C6, F, N, R6, P, T, T10-13, X Std., A3, C, C6, F, N, P, R6, T, T10-13, X Std., A12, C, C6, F, P, b Std., A3, C, C6, P, b N, R6, T, T10-13 N, R6, T, T10-13 Standard and All Forms Standard and All Forms Standard and All Forms
30
SMW
25
Electrically Held Electrically Held Mechanically Held Electrically Held Mechanically Held Electrically Held Mechanically Held Electrically Held
60
SPW
25
2&3 Mechanically Held 100 SQW 4&5 Electrically Held Mechanically Held Electrically Held Mechanically Held Electrically and Mechanically Held Electrically and Mechanically Held Electrically and Mechanically Held
3/4"
2 1/2"
34.50 23.50 101.00 Floor Mounting 876 597 2565 X hub is 1/4" left of center. W hub shown is another X hub. K dimension is distance between two X hubs. Actual W hub is located 3-3/16" to the right of X hub shown. All K forms. For glass polyester (through 100A), see Size 2 NEMA 4/4X dimensions on page 16-24. With or without any Forms
D1 N
A E
D2
C P
A E
G1 F C F B
J M X Y H1 H2 M X K L H
W X J K
NEMA 4 and 4X
NEMA 3R
16-73
16
Lighting Contactors
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
Approximate Dimensions
Table 16.206: NEMA 12/3R
Ampere Rating Type Number of Poles Form(s) Standard, F, R6, Y48 Any A3, A12, C, C6, P, T Electrically Held Mechanically Held 30 SMA 2-5 Electrically Held Electrically Held Mechanically Held Electrically Held Mechanically Held Electrically Held Mechanically Held Electrically Held 2&3 Mechanically Held 100 SQA 4&5 Electrically Held Mechanically Held Electrically Held Mechanically Held Electrically and Mechanically Held Electrically and Mechanically Held Electrically and Mechanically Held Std., A12, C, C6, P, X Std., F, P, X T N, R6 A3, C, C6, T, N, P R6 , Std., A12, C, C6, P, X Std., A3, C, C6, P X , T, N, R6 A3, C, C6, T, N, P R6 , Std., A12, C, C6, F, N, R6, P, T, T10-13, X Std., A3, C, C6, F, N, P, R6, T, T10-13, X Std., A12, C, C6, F, N, P b , Std., A3, C, C6, P b , N, R6, T, T10-13, b N, R6, T, T10-13, b Standard and All Forms Standard and All Forms Standard and All Forms Dimensionsa A 8.13 206 11.88 302 6.38 162 11.88 302 14.88 378 8.13 206 14.88 378 B 8.50 216 7.75 197 8.53 217 7.75 197 7.88 200 9.28 236 7.88 200 C 15.75 400 13.50 343 12.75 324 13.50 343 16.00 406 16.00 406 15.75 400 D 1.56 40 3.81 97 1.56 40 2.56 65 2.56 65 1.56 40 2.56 65 E 5.00 127 4.25 108 3.25 83 6.75 171 9.75 248 5.00 127 9.75 248 F 15.00 381 12.75 324 12.00 305 12.75 324 15.00 381 15.00 381 15.00 381 G .31 8 .38 10 .38 10 .38 10 .50 13 .50 13 .38 10 H 2.13 54 4.94 125 3.56 90 3.66 93 3.66 93 3.66 93 3.66 93 I 14.75 375 18.12 460 12.50 318 18.12 460 21.25 540 15.38 391 21.25 540 J .31 8 .31 8 .31 8 .31 8 .31 8 .31 8 .31 8
30
LA LXA
60
SPA
2-5
18.15 461
9.24 235
31.50 800
3.08 78
12.00 305
30.50 775
.50 13
3.67 93
26.71 678
.44 11
22.15 563 22.15 563 17.21 437 20.21 513 93.00 2362
10.24 260 10.24 260 13.33 339 13.00 330 34.50 876
41.50 1054 41.50 1054 47.00 1194 65.00 1651 23.50 597
Floor Mounting
See Figure 1 for all dimensions except 800 A; for 800 A dimensions, see Figure 2. All Type K Forms using Class 9001 Type K Control Units.
Disconnect Switch & Circuit Breaker Types Disconnect Switch & Circuit 60 Breaker Types Disconnect Switch & Circuit 100 Breaker Types Disconnect Switch Type 200 Circuit Breaker Type c Conduit size.
A E
H J
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
I
C B C E F A
Figure 3: NIGHT-MASTER
16-74
Lighting Contactors
Class 8903 / Refer to Catalog 8903CT9701R8/08
www.schneider-electric.us
Approximate Dimensions
Table 16.209: Combination Lighting ContactorsNEMA 1 Enclosure
Ampere Rating Type SMG6 & 8 30 SMG7 & 9 SPG6 & 8 60 SPG7 & 9 Dimensionsa (see Figure 1) A 9.50 241 B 22.50 572 C 8.37 213 D 6.38 162 E F G 20.50 14.68 1.81 521 373 46 H 1.69 43 1.88 48 I 3.37 86 3.76 96 4.00 102 4.00 102 J 3.38 86 2.06 52 2.06 52 2.56 65 K 1.06 27 1.06 27 1.06 27 1.31 33 L 3.25 83 3.25 83 3.25 83 3.25 83 M 2.18 55 2.18 55 2.18 55 2.18 55 N 1.25 32 1.25 32 1.25 32 1.25 32 O .87 22 .87 22 .87 22 .87 22 Top & Bot. W .50.75 .50.751.0 1.01.25 1.01.25 X .50.75 .50.751.0 .50.75 .50.75 Sides Y .50
A D
M K
Handle Swing L
C N Y
E B
13.75 23.00 349 584 10.50 26.00 267 660 15.00 28.75 381 730
9.62 7.37 24.00 17.00 2.12 2.00 244 187 610 432 54 51 9.62 11.62 26.25 21.50 2.18 2.00 244 295 667 546 55 51
G J H I
A D
C N Y
Cover Open 90 F W X W
(4) .44 Dia. Mtg. Holes 11 (For Sizes 100 & 200 A) (4) .56 Dia. Mtg. Holes Located on 14 External Flanges (For Size 300 A)
J K H I
G C
Cover Open 90
(4) .31 Dia. Mtg. Holes 8 (For Sizes 30 & 60 A) (4) .44 Dia. Mtg. Holes 11 (For Sizes 100 & 200 A) (4) .56 Dia. Mtg. Holes Located on 14 External Flanges (For Size 300 A)
X J
Handle Swing D
G C
Cover Open 90 L
(4) .31 Dia. Mtg. Holes 8 (For Sizes 30 & 60 A) (4) .44 Dia. Mtg. Holes 11 (For Sizes 100 & 200 A) (4) .56 Dia. Mtg. Holes Located on 14 External Flanges (For Size 300 A)
400 SYA81 & 91 Floor Mounting Enclosure 600 SZA81 & 91 a Dimensions are the same for Form F4T (standard control transformer), Form F4T11 (100 VA extra capacity) and Form F4T12 (200 VA extra capacity).
16-75
16
Definite purpose contactors are ideal for heating, air conditioning, refrigeration, data processing, and food service equipment. New compact 1 and 2-Pole contactors are available along with standard size 2, 3, and 4-Pole devices. They feature quick connect terminals and binder head screws for easy wiring. Box lugs are standard on 40 ampere contactors and larger. An exclusive DIN track mounting option may reduce installation costs. Coils can be changed on the Type DPA contactors quickly without a tool. Auxiliary contact modules snap on either side of the Type DPA contactors.
50 A Resistive, maximum 277 V. All others rated 40 A Resistive (above 277 V). Above 240 V, all lines must be switched. Voltage code must be specified to order this product. Refer to standard voltage codes listed below.
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-76
CP1B
Discount Schedule
Table 16.224: Factory Modifications Auxiliary contacts can be factory installed along with a DIN mounting bracket option. Special terminations are also available.
Modification Factory installed auxiliary contacts Pressure wire connectors (2030 A) Box lugs (2030 A) DIN mounting bracket attached (35 mm style)i Type DPA DP DPA DP DPA DP Form h Y122 Y124 Y135 Y248 U1 $ Price h 1.70 per pole 3.30 per pole 3.30 8.70 2.10 No Charge
Table 16.219: NEMA 1 General Purpose Enclosures for Type DP, DPA and SYD Contactors
Class 8910 Type DP DPA Full Load Amperes 2040 2040 50 DPA 2040 DPA 6075 DPA 90 CP1 discount schedule. Poles 1&2 2&3 2&3 4 2&3 2&3 Class 9991 Type DPG1 DPG1 DPG2 DPG3 DPG4 $ Price c 78.00 78.00 99.00 143.00 287.00
Contact your nearest Square D/Schneider Electric sales office. Available for 20 through 60 A only.
Coil Replacement
No tools required
CP1B
CP1
CP10
Discount Schedule
16-77
16
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Type DPA2 and 3-Pole 20 through 40 Full Load Amperes Type DPA4-Pole 20 through 40 Full Load Amperes
16-78
.23
6
2.11
54
.26
7
2.87
73 64
.51
13
1.54
39
.23
6
.07
2
.09
2
.44
11
2.50
.26
7
.06
2
3.27
83
4.06
103
3.72
94
4.44
113
4.63
118
5.20
132
5.12
130
2.56
65
.24
Provisions for (4) #10 or M5 Mounting Screws
3.67
93
3.39
86
4.37
Provisions for #10 or M5 Mounting Screws 111
.39
10
16-79
16
Class 8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. Definite purpose starters offer:
Low cost Small size Melting alloy overload block Trip-free reset mechanism Open type or enclosed 500,000 mechanical operations
Type DPSO23V02
115 V 230 V 230 V 460/575 V 1 1 3 3 20 1 1/2 3 2-Pole 25 2 5 Single 30 2 5 Phase 40 3 7 1/2 50 3 10 20 1 1/2 3 7 1/2 7 1/2 3-Pole 25 2 5 10 15/20 Poly30 2 5 10 15/20 Phase 40 3 7 1/2 10 20/25 50 3 10 15 30 a Prices do not include thermal units. Standard trip thermal units are priced at $21.50 each. See page 16-125 for selection information. b Holding circuit contacts are not provided as standard; refer to table below for kit. c Voltage code must be specified to order this product. Refer to standard voltage codes listed below.
Type DPSG23V02
Approximate Dimensions
3.50 89 1.60 41
4.00 102
Type DPSO2 and 3-Pole and DSO 2050 Full Load Amperes
6.00 152 3.00 76
Description Class & Type $ Price Start-Stop push button kitef 8911DPB1 134.00 Hand-Off-Auto selector switch kite 8911DSS1 134.00 Standard N.C. overload relay contact 9998SO1 42.80 N.C. and N.O. isolated overload relay 9999SO4 116.00 alarm contacts Overload relay jumper strap 9998SO31 14.30 e Use for 20 to 40 A starters. For 50 A starters, use the 9999BLX bracket. f Does not include holding circuit interlockorder auxiliary contact.
.88 22
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
.94 24 4.13 105
.94 24
1.00 25
DPSG33
16-80
CP1
CP1B
CP10
Discount Schedule
Class 8940 panels in NEMA 3R enclosures are specifically designed for pumping applications. Featuring IEC Style contactors and overload relays. Approved for submersible pump applications Class 10 overload relay through 100 hp480 V, 50 hp240 V Adjustable trip current All prices include a START push button and a HANDOFF-AUTO selector switch.
Ambient temperature compensated overload Phase failure sensitive through 100 hp480 V, 50 hp240 V Sizes closely matched to common motor sizes All devices are UL Listed, and marked SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT
240
24060 22050
Type NPF4030
48060 44050
a b c
60 75 100 Circuit breaker disconnect supplied. Fuse clips are sized for use with dual-element time-delay fuses. Coil voltage code must be specified to order this product. Refer to standard voltage codes listed below.
Type NPG4050
e
CP1
Discount Schedule
16-81
16
NOTE: Motor LogicSSOLR are designed to protect 50/60 hertz three-phase AC motors from overload and phase loss conditions. Open Delta systems or grounded B-phase systems are difficult to balance and could cause the Motor Logic SSOLR to trip. For applications of this nature, it is recommended that bi-metallic overload relays (Form B12) be used. Class 8940 Type NS, SS, and XS panels in NEMA 3R enclosures are specifically designed for pumping applications. Extra space is provided for field installation of auxiliary equipment. Type S Contactor provided as standard Approved for submersible pump applications Class 10 Motor Logic SSOLR through 200 hp480 V, 100 hp240 V, Type SS only (Includes rubber boot.) All prices include a START push button and a HAND-OFF-AUTO selector switch Adjustable trip current Phase failure sensitive through 200 hp480 V, 100 hp240 V, Type SS only Ambient temperature compensated overload All devices are UL Listed, and marked SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT NOTE: Class 10 Motor Logic SSOLR does not protect for phase imbalance. Table 16.238: 3-Pole Polyphase480 Vac Maximum (5060 Hz)Fusible or Thermal Magnetic Breakera
Volts Maximum Hp Polyphase 3, 5, 7-1/2 10, 15 20, 25, 30 40, 50 75 100 100 200 250, 300 3, 5, 7-1/2, 10 15, 20, 25 30 40, 50 60, 75, 100 150 200 200 300, 350, 400 500, 600 Coil Voltage Fuse Clip Amperesc 30 60 100 200 DLL36400E20e 400 DLL36600E20e MJL36800e PLL34120e 30 60 60 100 200 DLL36400E20e 400 DLL36600E20e MJL36800e PLL34120e Type SSC2007d SSD2015d SSE2030d SSF2050d XSG2075b SSG2100d XSG2100b XSH2200b XSJ2300b SSC4010d SSD4025d SSD4030d SSE4050d SSF4100d XSG4150b SSG4200d XSG4200b XSH4400b XSJ4600b $ Price 2003.00 2480.00 4194.00 7718.00 19890.00 16286.00 19890.00 58145.00 58145.00 2003.00 2480.00 3338.00 4194.00 7718.00 19890.00 16286.00 19890.00 58145.00 58145.00
24060 22050
240
Type SSD4030
48060 44050
480
Table 16.239: 3-Pole Polyphase480 Vac Maximum (5060 Hz)Circuit Breaker (MCP)
Max. Hp Coil Circuit Type $ Price Polyphase Voltageb Breakerf 30 HLL36100M73 XSE2030V03 4599.00 24060 240 40 22050 JLL36250M75 XSE2040V03 7650.00 50 JLL36250M75 XSF2050V03 8258.00 40 XSE4040V06 4599.00 HLL36100M73 50 XSE4050V06 4599.00 48060 480 44050 75 JLL36250M75 XSE4075V06 7650.00 100 JLL36250M75 XSF4100V06 8258.00 To substitute an IEC ambient compensated bimetallic overload relay (up to size 5) for the Motor Logic SSOLR, request Form B12 and state motor hp (no charge). This applies to the above (SSx) devices only. See page 16-81 for coil voltage codes and pricing. Fuse clips are sized for use with dual-element time-delay fuses. Voltage code not required for 240 V or 480 V common control with 8940SS controllers. Circuit breaker disconnect supplied. (See page 7-32 for circuit breaker adjustment range.) See page 7-32 for circuit breaker adjustment range. Volts
Type SSE4050
b c d e f
16
g
Table 16.241: Class 10 Pump Panel Replacement Motor Logic SSOLR (with rubber boot)
Description Pump Panel SSOLR 27A Special Pump Panel SSOLR 45A Special Pump Panel SSOLR 90A Special Pump Panel SSOLR 135A Special Pump Panel SSOLR 270A Special Pump Panel SSOLR 540A Special Pump Panel SSOLR 810A Special Catalog Number 3116154764 (Size 1) 3116154883 (Size 2) 3116155158 (Size 3) 3116155368 (Size 4) 3116118474 (Size 5) 3116118476 (Size 6) 3116118477 (Size 7) $ Price $192.00 270.00 329.00 477.00 221.00 221.00 221.00
16-82
CP1
Discount Schedule
Class 8940 S2 Pumping Plant Panels in NEMA 3R enclosures are specifically designed for oil field applications. All panels are supplied with a Mag-Gard circuit breaker or a visible blade, fused, disconnect switch. This line of pumping plant panels features: Rugged spring latches for easy access without a tool Side mounted control units for convenient operation Door retainer available for windy areas Price includes Hand-Off-Auto selector switch UL Listed for use as service equipment for motors Extra panel space for additional electrical controls All devices are UL Listed, and marked SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT Thermal units must be ordered separately at $21.50 each. See page 16-125 for selection information. NOTE: Overload relays are ambient temperature compensated. Table 16.238: 3-Pole Polyphase480 Vac Maximum (5060 Hz)
Type WC3S2V06
Volts Max. Hp Polyphase 7-1/2 10 240 15 30 50 10 15 480 25 50 a b 48060 44050 24060 22050 Coila Voltage NEMA Size 1 2 3 4 1 2 2 3 Fusible Disconnect Type Fuse Clip Amperesb 30 60 100 200 30 60 100 Type WC1S2V03 WD1S2V03 WE1S2V03 WF1S2V03 WC3S2V06 WD3S2V06 WE3S2V06 $ Price 2109.00 2880.00 4649.00 8724.00 2109.00 2919.00 4748.00 Frame Size HLL36030M71 HLL36050M72 HLL36100M73 HLL36100M73 JLL36250M75 HLL36030M71 HLL36030M71 HLL36050M72 HLL36100M73 Circuit Breaker Type Type XC1S2V03 XD1S2V03 XD2S2V03 XE1S2V03 XF2S2V03 XC4S2V06 XD3S2V06 XD4S2V06 XE3S2V06 XF4S2V06 $ Price 2228.00 2997.00 2997.00 4886.00 8963.00 2262.00 3036.00 3036.00 4986.00 9036.00
100 4 200 WF3S2V06 8801.00 JLL36250M75 Coil voltage code must be supplied to order this product. See Coil Voltage Codes table to the left for codes. Fuse clips are sized for use with dual-element time-delay fuses.
f g
CP1
Discount Schedule
16-83
16
Approximate Dimensions
Table 16.241:
Type NPD/E/F SSC SSD NPG/J SSE/F XSE/F WCS2 WDS2 XCS2 XDS2 WES2 WFS2 XES2 XFS2 SSG XSG XSH XSJ Fig. 1 1 A IN mm IN B mm IN C mm IN D mm IN E mm IN F mm 963 IN G mm IN H mm IN J mm IN K L M mm R Knockouts S 1-1/4 1-1/2 T IN V mm mm Conduit IN 2-1/2 2-1/2
6.67 169
839 37.93
7.00 178 2.41 61 3.00 76 3.00 76 7.00 178 2.17 55 2.69 68 3.44 87
2.41 61 1/23/4
1/23/4 1.41 36
2.57 65 1/23/4 11-1/4 11-1/4 1.41 36 12-1/2 1-1/22 2.12 54 1/23/4 11-1/4 1/23/4 1-1/2
7.29 185
864 37.38
949
1-1/2
1 1 2 2
2.68 68 1/23/4 11-1/4 11-1/4 1.50 38 22-1/2 1-1/22 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 1.50 38 N/A N/A N/A N/A
75.50 1892 22.00 559 13.80 351 17.55 446 73.00 1854 74.50
82.50 2096 36.00 914 20.00 508 23.25 591 80.00 2032 33.75 857 16.50 419 N/A N/A N/A N/A N/A N/A 92.50 2350 34.00 864 20.00 508 23.25 591 90.00 2286 31.75 806 16.50 419 N/A N/A N/A N/A N/A N/A
NOTE: Illustrations may not represent the actual enclosure; they are intended for dimensional information only.
Figure 2
Figure 1
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-84
Class 8941
Duplex Motor Controllers are used to control two motors, and consist of two starters in a common enclosure. Two separate disconnect switches or circuit breakers with operators are included with all combination devices. Unless Form Y68 is specified, an alternation circuit (a Class 8501 Type XO40 relay) is included, which alternately operates first one motor and then the other on each successive closing of a pilot device. Both motors will be energized should a second pilot device close. All devices incorporate a terminal block to simplify wiring of pilot devices A and B. Typical applications include pump motors where a second pump is required for peak demand periods yet alternation is desirable to equalize pump wear. Table 16.242: 3-Pole Polyphase600 Vac Maximum (5060 Hz) Non-Combination TypeWithout DisconnectWith Electric Alternation Note that the prices shown do not include thermal units. Devices require 6 thermal units. Standard trip thermal units are $21.50 each. See page 16-125 for selection information.
Maximum Rating Each Motor Voltage 0 1 2 3 4 200230 460575 200230 460575 200 230 460575 200 230 460575 200 230 460575 Hp Polyphase 3 5 7-1/2 10 10 15 25 25 30 50 40 50 100 NEMA 1 General Purpose Enclosure Type NBG10b NCG20b NDG30b NEG40b NFG50b $ Price 2322.00 2478.00 3731.00 5112.00 10440.00 NEMA 4/4X Watertight and Dusttight Enclosure Stainless Steel Type NBW10b NCW20b NDW30b NEW40b NFW50b $ Price 3105.00 3290.00 5427.00 8303.00 15881.00 NEMA 12 (NEMA 3 and 3R)a Dusttight and Driptight Industrial Use Enclosure Type NBA10b NCA20b NDA30b NEA40b NFA50b $ Price 2564.00 2721.00 4359.00 5925.00 13131.00 Type NBO10b NCO20b NDO30b NEO40b NFO50b Open Type
NEMA Size
Table 16.243: 3-Pole Polyphase600 Vac Maximum (5060 Hz) Combination Thermal Magnetic Circuit Breaker TypeWith Electric Alternation Note that the prices shown do not include thermal units. Devices require 6 thermal units. Standard trip thermal units are $21.50 each. See page 16-125 for selection information.
Motor Starter Voltage Max. Hp Polyphase 2 3 5 7-1/2 200 (208) 10 15 20 25 30 40 2 3 5 7-1/2 230 (240) 20860 Coil Voltage b Circuit Breaker Frame Size HLL36015 HLL36020 HLL36035 HLL36050 HLL36060 HLL36100 HLL36125 HLL36150 JLL36200 JLL36250 HLL36015 HLL36020 HLL36035 HLL36045 Ampere Rating 15 20 35 50 60 100 125 150 200 250 15 20 35 45 NEMA 1 General Purpose Enclosure Type CBG06b CBG08b CCG12b CCG15b CDG22b CEG32b CEG36b CEG38b CFG41b CFG44b CBG06b CBG08b CCG14b CCG16b $ Price 3945.00 4103.00 5826.00 9401.00 19584.00 3945.00 4103.00 NEMA 12 NEMA 4/4X (NEMA 3 Watertight and Dusttight and 3R)a Stainless Steel Enclosure Dusttight and Driptight Industrial Use Enclosure Type CBW06b CBW08b CCW12b CCW15b CDW22b CEW32b CEW36b CEW38b CFW41b CFW44b CBW06b CBW08b CCW14b CCW16b $ Price 6951.00 7109.00 10470.00 17490.00 29924.00 6951.00 7109.00 Type CBA06b CBA08b CCA12b CCA15b CDA22b CEA32b CEA36b CEA38b CFA41b CFA44 b CBA06b CBA08b CCA14b CCA16b CDA22b CDA24b CEA38b CFA43b CFA44b CBA10b CCA18b CCA20b CDA26b CDA28b CDA30b CEA39b CEA40b CFA45b CFA47b $ Price 4701.00 4859.00 6894.00 10782.00 23400.00 4701.00 4859.00 6894.00 10782.00 23400.00 5612.00 5769.00 7806.00 10782.00
NEMA Size
0 1 2 3 4 0 1
CP1
Discount Schedule
16-85
16
24060 10 HLL36060 60 CDG22b CDW22b 2 5826.00 10470.00 22050 15 HLL36090 90 CDG24b CDW24b 25 3 HLL36150 150 CEG38b 9401.00 CEW38b 17490.00 30 40 JLL36225 225 CFG43b 19584.00 CFW43b 4 29924.00 50 JLL36250 250 CFG44b CFW44b 5 0 HLL36015 15 CBG10b 4859.00 CBW10b 7862.00 7-1/2 HLL36025 25 CCG18b CCW18b 1 5013.00 8019.00 10 HLL36030 30 CCG20b CCW20b 15 HLL36045 45 CDG26b CDW26b 460 20 48060 2 HLL36060 60 CDG28b 6737.00 CDW28b 12881.00 (480) 25 44050 HLL36070 70 CDG30b CDW30b 30 HLL36080 80 CEG39b CEW39b 3 9401.00 17490.00 50 HLL36150 150 CEG40b CEW40b 75 JLL36200 200 CFG45b 19584.00 CFW45b 4 29924.00 100 JLL36250 250 CFG47b CFW47b a NEMA 12 enclosures may be field modified for outdoor applications. For details refer to Class 9991, page 16-104. b Coil voltage code must be specified to order this product. Refer to standard voltage codes listed on page 16-87. Note: For voltage codes used with control transformers, see page 16-110.
23400.00
Table 16.244: 3-Pole Polyphase600 Vac Maximum (5060 Hz) Combination Disconnect Switch TypeWith Electric Alternation Note that the prices shown do not include thermal units. Devices require 6 thermal units. Standard trip thermal units are $21.50 each. See page 16-125 for selection information.
Motor Voltage (Starter Voltage) Max. Hp Polyphase 3 Coil Voltage c NEMA Size Fuse Clip Size Ampsb NEMA 1 General Purpose Enclosure NEMA 4/4X Watertight and Dusttight Enclosure Stainless Steel NEMA 12 (NEMA 3 and 3R)a Dusttight and Driptight Industrial Use Enclosure
Type $ Price Type $ Price Type $ Price None UBG10c 3731.00 UBW10c 6737.00 UBA10c 4487.00 30 DBG08c 3816.00 DBW08c 6822.00 DBA08c 4572.00 None UCG20c 3888.00 UCW20c 6894.00 UCA20c 4644.00 7-1/2 1 60 DCG18c 3974.00 DCW18c 6980.00 DCA18c 4730.00 200 208-60 (208) None UDG30c 5642.00 UDW30c 10283.00 UDA30c 6708.00 10 2 60 DDG28c 5754.00 DDW28c 10398.00 DDA28c 6822.00 UEG40c 8798.00 UEW40c 16892.00 UEA40c 10184.00 None 25 3 DEG38c 9072.00 DEW38c 17163.00 DEA38c 10454.00 200 None UBG10c 3731.00 UBW10c 6737.00 UBA10c 4487.00 3 0 30 DBG08c 3816.00 DBW08c 6822.00 DBA08c 4572.00 None UCG20c 3888.00 UCW20c 6894.00 UCA20c 4644.00 7-1/2 1 60 DCG18c 3974.00 DCW18c 6980.00 DCA18c 4730.00 230 240-60 (240) 220-50 None UDG30c 5642.00 UDW30c 10283.00 UDA30c 6708.00 15 2 60 DDG28c 5754.00 DDW28c 10398.00 DDA28c 6822.00 None UEG40c 8802.00 UEW40c 16892.00 UEA40c 10184.00 30 3 200 DEG38c 9072.00 DEW38c 17163.00 DEA38c 10454.00 None UBG10c 3731.00 UBW10c 6737.00 UBA10c 4487.00 5 0 30 DBG10c 3833.00 DBW10c 6836.00 DBA10c 4586.00 None UCG20c 3888.00 UCW20c 6894.00 UCA20c 4644.00 480-60 10 1 30 DCG20c 3987.00 DCW20c 6993.00 DCA20c 4743.00 460 440-50 (480) 575 None UDG30c 5642.00 UDW30c 10283.00 UDA30c 6708.00 25 2 (600) 60 DDG30c 5796.00 DDW30c 10440.00 DDA30c 6866.00 None UEG40c 8802.00 UEW40c 16892.00 UEA40c 10184.00 50 3 100 DEG40c 9230.00 DEW40c 17319.00 DEA40c 10611.00 a NEMA 12 enclosures may be field modified for outdoor applications. For c Coil voltage code must be specified to order this product. Refer to details refer to Class 9991, page 16-104. standard voltage codes listed on page 16-87. b Hp rating applies only when dual element time delay fuses are used. Note: For voltage codes used with control transformers, see page 16-110. 0
1083.00 1596.00
FF4T 1395.00 FF4T11 1994.00 FF4T12 2478.00 F4T11 F4T12 G97 D R7 R8 S X10 X01 Y24 Y68 G56e G50e 1446.00 1853.00 1652.00 755.00 1454.00 2178.00 No Charge 315.00 315.00 314.00 869.00 116.00 57.00
1710.00 2222.00 2564.00 2393.00 2849.00 3135.00 g 2934.00 3392.00 g 3675.00 g 1767.00 2222.00 2303.00 2763.00 1652.00 1652.00 755.00 755.00 1454.00 1454.00 2178.00 2178.00 No No Charge Charge 315.00 315.00 314.00 869.00 116.00 57.00 315.00 315.00 314.00 869.00 116.00 57.00 f f 1652.00 755.00 1454.00 2178.00 No Charge 315.00 315.00 314.00 869.00 116.00 57.00
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Single primary voltage must be specified. These Forms are most commonly used. Other Forms may be available. Consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733) for additional information.
Table 16.246:
NEMA Size 0&1 2 3 4 Standard Capacity 100 VA Additional Capacity 200 VA Additional Capacity (Form F4T) (Form F4T11) (Form F4T12) Class 9070 Type T100 T100 T150 T300 Class 9070 Type T200 T200 T300 T500 Class 9070 Type T300 T300 T500 T500
16-86
CP1
Discount Schedule
Approximate Dimensions
Table 16.247: NEMA 1 EnclosureNon-Combination (Figure 1)
Starter Size 0, 1, or 2 3 or 4 A 20-1/2 22-1/8 B 24-1/8 34 C 8-11/16 9-3/4 D 17-7/8 16 E 21-1/2 35-1/2 F 1-5/16 3-1/16 G 1-5/16 3/4 H 5/16 Dia. 7/16 Dia.
A F D
G
9/16 Dia.
Figure 1
Handle Swing C
A H D J
E B
Figure 2
H G E G J Mtg. Holes
D F B
Figure 3
H G E G J Mtg. Holes
NOTE: Illustrations may not represent the actual enclosure; they are intended for dimensional information only. Dimensions are in inches.
D F
C Handle Swing
Figure 4
16-87
16
Reversing/Hoist, Type R
Class 8965 / Refer to Catalog 8910CT9301
www.schneider-electric.us
Class 8965 Reversing Hoist Contactors meet the small space requirements found in electrical hoists, light duty cranes, door operators, and related products. They are designed to perform in the short periods of jogging
experienced in hoist service. Note that these contactors must be mounted upright on the vertical plane; the contactors will not operate properly when mounted in any other position.
Type RO10V02
a b
Jumper straps connect the line side power terminals of the same phase between the forward (up) and reverse (down) contactors in common; i.e. L1 to L1, L2 to L2 and L3 to L3. Coils rated 120 Vac or less are supplied with quick connect terminals
Quick Connect RO10c RO11c 998.00 Pressure Wireb RO12c RO13c only. c Voltage code must be specified to order this product. Refer to standard voltage codes shown in the coil table below.
Table 16.255: Miscellaneous Hoist Contactor Kits For Use With Class 8965
Type Series Description Class Type RO10 Armature Kit 9998 RP1e RO11 A&B Contact Order as Part Number RO12 Carrier 3100206050 RO13 d CP10 discount schedule. e One armature per kit. Note: See page 16-116 for replacement contact kits. Series C Description Armature Kit Contact Carrier Class 9998 Type RP2e $ Priced 29.40 39.40
C G
50.00
F
D A
8965
8965
8965
8965
8965
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Application Data
Coils Burden Duty: Hoist Duty-H4 Intermittent Voltage Range: AC coils only +10%,-15% of nominal Inrush 76 VA, Sealed 27 VA
Approvals
UL Component Recognized: File E78351, CCN NLDX2 CSA Certified: File LR60905, Class 3211 04
16-88
CP1
CP10
Discount Schedule
Class 8965 Type DPR reversing/hoist contactors are designed for the control of motors in hoists, overhead doors, small elevators, commercial laundry equipment, and other related products which use reversing motors. They are rated to perform in the short periods of jogging experienced in hoist service. The coils are designed to operate on line voltages of 85% to 110% of rated voltage, and are for applications at 50 or 60 Hz only. Coils are easily replaced with external base removed. Auxiliary contacts may be easily fieldadded to any Class 8965 reversing contactor. Type DPR contactors accept one auxiliary contact module with up to two isolated circuits per side (two modules per device). When auxiliary contacts are ordered separately, two modules are normally used for each device; one for forward, one for reverse.
Type DPR23V02
For rapid operation (jogging duty), use the next larger size contactor. Order two replacement coils for reversing contactors. CP10 Discount Schedule, not CP1. See page 16-116 for replacement contacts. Voltage code must be specified to order this product. Refer to standard voltage codes listed below.
Approvals
UL Component RecognizedFile E42240, CCN NLDX CSA CertifiedFile LR25490, Class 3211 04
Approximate Dimensions
3.37
86
3.98
101
6.87
174
3.07
78
5.87
149
CP1
CP10
Discount Schedule
16-89
16
Melting Alloy
Class 9065 / Refer to Catalog 9065CT9701
www.schneider-electric.us
Exclusive One-Piece Thermal Unit Inverse Time Delay Trip Trip Free Reset Mechanism on Types G & S Replaceable Contact Units on Types G & S
Note that the prices shown on this page do not include thermal units. Standard trip thermal units are $21.50 each. Slow trip (Class 30) and quick trip (Class 10) melting alloy thermal units are available for all Size 1, 2, 5 and 6, and some Size 3 and 4 applications. Table 16.265: For Separate MountingMelting Alloy600 Volts Maximum, AC or DCa
NEMA Size Maximum Full Load Current (A) Open Type for Separate Panel Mounting Left Hand Type Right Hand Type $ Price For Terminal Block Channel Mounting Order Open Type Relay and Bracket Kit Below Type $ Price
Type CO1R
Single Pole Construction (One N.C. Contact)1 Thermal Unit Required 1 25 CO1b CO1Rb 64.00 2 45 TO1b TO1b 72.00 3 86 UO1b UO1b 122.00 4 133 FO1Lb FO1Rb 192.00 5 266 GO11Lb GO11Rb 777.00 Three Pole Construction (One Common N.C. Contact on Type S Only)3 Thermal Units Required 1 25 SEO5 129.00 SM2 35.60 2 45 SEO8 185.00 SM2 35.60 3 86 SEO12 243.00 4 133 SEO15 386.00 5 266 Use 3 Type GO11R Relays Listed Above a Maximum power circuit rating for separate mounting overload relays, Types C, F, G, T and U, is 600 Vac or Vdc; Type S is 600 Vac only. Maximum control circuit contact rating for Types C, F, G, T, U and SDO18 is 600 Vac and 250 Vdc; the remaining Type S versions are 600 Vac only b Not UL listed.
Table 16.266: Replacement Melting Alloy Overload Relays for Square D Class 8536 Starters
Locate Class 8536 Starter in this Column NEMA Size 00 Type SA Series A&B Number of Poles 2 3 2 35 2 35 2 2 35 2 3 4 5 3 4 5 Order Class 9065 Overload Relay from this Column Type $ Price Number of Thermal Units Required
Type SE05
SDO4 86.00 1 SDO5 149.00 3 SDO4 86.00 1 0 SB A SDO5 149.00 3c SDO4 86.00 1 1 SC A SDO5 149.00 3c 1P SC A SDO10 116.00 1 SDO7 116.00 1 2 SD A SDO8 207.00 3c SDO11 143.00 1 SDO12 264.00 3 3 SE A SDO13 264.00 2 SDO14 264.00 3 SDO15 414.00 3 4 SF A SDO16 414.00 2 SDO17 414.00 3 SDO18 Series A 777.00 1 5 SG A 3 Form Y500 and Series B use SEO5 129.00 3 6 SH A&B 3 SEO5 129.00 3 For 4-pole starters used on two phase systems order two thermal units plus one Class 9998 Type SO31 jumper strap kit for every two starters. Each kit includes two jumper straps.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-90
CP1
Discount Schedule
Solid State Overload Relay, Motor Logic and Motor Logic Plus
Class 9065 / Refer to Catalog 9065CT9701 Table 16.271: Feature Unit: Replacement SSOLR for Retrofit of Square D Type S Starter Solid State Overload Relay 600 Vac Maximum
Locate 8536 Starter in this column Order Class 9065 Overload Relay from this column NEMA Sizek Open Type $ Price Trip Class 10/20 00Bh 1.54.5 SFB20 221.00 00Ch 39 SFC20 221.00 0h 618 SF020 221.00 1h 927 SF120 221.00 2 1545 ST220 288.00 3 3090 ST320 351.00 4 45135 ST420 516.00 5i 90270 ST520 221.00 5j 90270 SF520 1074.00 6i 180540 ST620 221.00 7i 270810 ST720 221.00 Size 00B, 00C, 0, and 1 are supplied without lugs. Lower amperage loads can be protected by looping of power wires. Size 5, 6 and 7 Replacement Overloads are only for existing NEMA S starters with MOTOR LOGIC overload relay. External CTs and additional components are not included. Size 5 is a complete drop-in replacement for Square D NEMA S melting alloy, bimetallic, and Y500 overload relays only. NEMA Size 00B and 00C are not actual NEMA sizes. These designations are used to differentiate the lower FLA of these devices from the NEMA Size 00 Motor Logic Solid State Overload Relay. Full Load Current Range (Amperes)
Motor Logic
Base Unit relays feature: 3 to 1 adjustment for trip current; phase loss and unbalance protection; direct replacement for Type S melting alloy. They are ambient insensitive and selfpowered. Electrical remote reset is also available. NOTE: Motor Logic SSOLR are designed to protect 50/60 hertz three-phase AC motors from overload, phase unbalance and phase loss conditions. Open Delta systems or grounded B-phase systems are difficult to balance and could cause the Motor Logic SSOLR to trip. For applications of this nature, it is recommended that bi-metallic overload relays (Form B12) be used.
Motor Logic
Table 16.268: Base Unit: For Separate Mounting Solid State Overload Relay 600 Vac Maximum
Full Load Open Type NEMA Sizeg Current Range $ Price (3-Pole) Trip Class 10 Trip Class 20 (Amperes) 00Ca 39 SSC10 SSC20 192.00 0a 618 SS010 SS020 192.00 1a 927 SS110 SS120 192.00 2 1545 SS210 SS220 270.00 3 3090 SS310 SS320 329.00 4 45135 SS410 SS420 477.00 a Size 00C, 0, and 1 are supplied without lugs. Lower amperage loads can be protected by looping of power wires. Lugs are available, see page 16-120.
h i j k
Table 16.269: Base Unit: Replacement SSOLR for Retrofit of Square D Type S Starter Solid State Overload Relay 600 Vac Maximum
Locate 8536 Starter in this column Order Class 9065 Overload from this column
Full Load Open Type NEMA Sizeg Current Range $ Price Trip Class 10 Trip Class 20 (Amperes) 00Cb 3-9 SSC10 SSC20 192.00 0b 6-18 SS010 SS020 192.00 1b 9-27 SS110 SS120 192.00 2 15-45 SR210 SR220 251.00 3e 30-90 SR310 SR320 306.00 4e 45-135 SR410 SR420 449.00 5c 90-270 SR510 SR520 192.00 5d 90-270 SS510 SS520 1044.00 b Lug - Bar Kits are available for Size 00C, 0 and 1. Lower amperage loads can be protected by looping of power wires. See page 16-120. c Size 5 Replacement Overload is only for existing NEMA S starters with MOTOR LOGIC overload relay. External CTs and additional components are not included. d Size 5 is a complete drop-in replacement for Square D NEMA S melting alloy, bimetallic, and Y500 overload relays only. e Need 9999ER4 for reset bar.
Table 16.272:
Class 9065 SP Solid State Overload Relay $ Price Product Description Current Range SPB4 SPB6 0.52.3 A SPC4 SPC6 2.09.0 A SP14 SP16 6.027.0 A SP24 SP26 10.045.0 A 957.00 SP34 SP36 20.090.0 A SP44l SP46l 60.0135.0 A SP54m SP56m 120.0270.0 A SP64n SP66n 240.0540.0 A l Must use 150:5 external current transformer which is purchase separately. m Must use 300:5 external current transformer which is purchase separately. n Must use 600:5 external current transformer which is purchase separately. 200 to 480 V 600 V
Feature Unit relays include all of the features found on the Base Unit relays plus: switch selectable trip class; Class II ground fault detection; and direct replacement for Type S melting alloy. Electrical remote reset is also available. Table 16.270: Feature Unit: For Separate Mounting Solid State Overload Relay 600 Vac Maximum
NEMA Sizeg (3-Pole) Full Load Open Type Current Range $ Price Trip Class 10/20 (Amperes) 00B 1.54.5f SFB20 221.00 00C 39f SFC20 221.00 0 618f SF020 221.00 1 927f SF120 221.00 2 1545 SF220 309.00 3 3090 SF320 378.00 4 45135 SF420 545.00 Size 00B, 00C, 0, and 1 are supplied without lugs. Lower amperage loads can be protected by looping of power wires. Lugs are available. See page 16-120. NEMA Size 00B and 00C are not actual NEMA sizes. These designations are used to differentiate the lower FLA of these devices from the NEMA Size 00 Motor Logic Solid State Overload Relay.
Table 16.273: Forms for factory addition to 8536 Open Style only
Alpha Character B First Digit 2 3 4 5 6 7 8 9 Second Digit 0 2 4 6 MOTOR LOGIC Plus Overload Relay Current Ranges 0.52.3 A 2.09.0 A 6.027.0 A 10.045.0 A 20.090.0 A 60.0135.0 A 120.0270.0 A 240.0540.0 A Modifications No Modification for 200480 V Add Communication Module for 200480 V No Modification for 600 V Add Communication Module for 600 V
f g
Example
Form B 4 2 Motor Logic Plus overload relay with a current range of 627 A and modifications to add communication module for an open style starter package. See pages 16-10516-106 or dimensions. Accessories located on page 16-120.
CP1
Discount Schedule
16-91
16
Protection components
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T is a green motor management system with unique power monitoring capabilities for better energy management. TeSys T carries all appropriate and necessary third party certifications. See page 16-93. To get details information about TeSys T, visit our web at www.us.schneider-electric.com/TeSysT.
LMRR27EBD
Use the external current transformer for the 100 A to 1000 A range. See page 16-94 for details. For more information about the LTMR controller, see page 16-94. LTME Expansion Module The LTME expansion module, when added to the LTMR controller, provides power monitoring, energy management and voltage. The TeSys T expansion module makes the most of your energy. Table 16.276: New!
Input Voltage Catalog Number 24 Vdc LTMEV40BD 100240 Vac LTMEV40FM
LTMEV40FM
The LTME expansion module and the LTMR controller are connected side-by-side or remotely by cable. See page 16-94 for details. For more information about the LMTE expansion module, see page 16-94. LTMCU Compact Display The LTMCU compact display is an easy and intuitive way to connect to the TeSys T controller and allows full set-up through menus, full monitoring, full control and full commissioning. The LTMCU display allows you to make minor changes on the fly. For more flexibility, the LTMCU display is powered by the base unit and can be set up in multiple languages. Table 16.277: New!
Catalog Number LTMCU
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS LTMCU
The LTMCU compact display connects to the LTMR controller or the LTME expansion module with a cable, LU9R. See page 16-94 for details. For more information about LTMCU compact display, see page 16-94. For more information about TeSys T functionalities and communication capabilities, see page 16-93. Table 16.278: Configuration Tools and Accessories
Module Current transformers Ground sensor Thermistor probe Connecting cable Magelis compact display PowerSuite V2.6 or greater PowerLogic SMS 4.0 Quick Description Allows use of TeSys T up to 1000 A Measures ground currents Measure temperatures of motor windings Wire together the different modules Use only one HMI for up to 8 TeSys T controllers Configuration software for TeSys U and TeSys T Use with TeSys T power/energy management features Find out more and Select it... Page 16-95 Page 16-95 Page 16-95 Page 16-96 Page 16-94 Page 16-95 Page 16-95
16-92
I12
Discount Schedule
Protection components
www.schneider-electric.us
thermal overload phase imbalance and phase failure thermal motor protection via PTC probes phase reversal ground fault detection long starting times and motor stalling automatic load shedding and restarting load fluctuations (current, voltage, power) variations of Cos (power factor) Measurements (rms values):
current on the 3 phases voltage on the 3 phases (shedding) motor temperature ground fault sensing average current frequency Power factor, power, power consumption
Metering functions:
overload mode: monitoring of motors whose control is not managed by the controller (2 or 3 wire) independent mode: starting of full voltage non-reversing motors reverser mode: starting of full voltage reversing motors 2-step mode: 2-step starting of motors (star-delta, by autotransformer and by resistor) 2 or 3 wire 2-speed mode: 2-speed starting of motors (Dahlander, pole changer) 2 or 3 wire
Values calculated:
A custom mode is available to allow the user to create a specific motor control mode that is not predefined in the controller. Custom Logic has the basic functions of a small programmable logic controller (PLC). Programming can be done in Structured Text mode or in Block Diagrams through PowerSuite V2.6 software. To ensure consistency, the same software used to commission the TeSys T controller is used for Custom Logic programming. Statistical and diagnostic functions:
locally, using the logic inputs present on the product, or via the human machine interface (HMI) remotely, via the network
history of the last five detected faults motor statistics controller operations warning of pending faults
Possible Configurations: TeSys T controller is a flexible motor management system using PowerSuite V2.6 commissioning tool. PowerSuite is the configuration software for the TeSys T controllers. See page 16-95 for details.
LTM CU TeSys T PLC (automation platform)
PowerSuite
LTM CU
TeSys T
Network or bus
connector
PowerSuite LTMR
I12
Discount Schedule
16-93
16
PowerSuite
Protection Components
LTMR Controller:
The controller is the central component in the motor management system. It manages the basic functions such as:
measurement of 3-phase current via integral current transformers from 0.4 to 100 A (up to 1000 A by external current transformers) measurement of ground current internally or LMRR27EBD external ground sensors measurement of motor temperature inputs and outputs for the various motor control modes, detected fault management, and other functions
voltage measurement between phases up to 690 V nominal 4 additional inputs LTMEV40FM 4 discrete logic inputs (isolated) 2 types of power for the inputs: 24 Vdc and 100 to 240 Vac
A 24 Vdc LTMR controller can be assembled with a 240 Vac expansion module and vice versa
Inputs
Characteristics
As standard, the controller manages the following: Control Modes
The LTMVE must be connected to the LTMR controller by a connecting cable. Table 16.280: Expansion Module New!
Input Control Voltage 24 Vdc 100240 Vac Number of Inputs 4 4 Supply to the Electronics via the LTMR controller Catalog Number LTMEV40BD LTMEV40FM $ Price 300.00 300.00
overload mode independent mode reverser mode 2-speed mode 2-step mode Custom mode
Inputs/Outputs
6 discrete logic inputs 3 relay logic outputs (1 N.O.) 1 relay output for detected fault signalling (1 N.O. + 1 N.C.) overload relay
Measurements
connection for a thermistor probe connections for a ground sensor
24 Vdc 100240 Vac 24 Vdc 27 100240 Vac 24 Vdc 100 100240 Vac For EtherNet Modbus TCP 8 27 100 For CANopen 8 27 100 For DeviceNet 8 27 100 For Probibus DP 8 27 100 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac 24 Vdc 100240 Vac
Configure the parameters Display information Monitor the alarms and detected faults Local control of the motor via the local control interface (keys can be customized) Three different languages can be loaded into the LTMCU controller at the same time: English, French, Spanish are the defaults.
LTMCU
A language download utility (LangTool), together with all the other languages, are available on the website www.schneider-electric.com. This tool allows the languages present in the LTMCU control until to be adapted. The LTMCU HMI control unit has an additional front panel RJ45 port, protected by a flexible cover.
Magelis Display:
Two applications have been predefined for the TeSys T controller. Depending on the application loaded, the HMI terminal makes it possible to:
Configure and monitor a motor starter (LTM_1T1_V1.dop) Monitor and modify certain parameters up to 8 motor starters (LTM_1T8_X_V1.dop)
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
XBTL1000 programming software is needed for loading applications into the XBT HMI terminal. Table 16.281: HMI Modules and Software New!
Description Operator Control unit Magelis compact display Configuration software Windows 99, 2000, XP Supply Voltage via the LTMR controller 24 Vdc Catalog Number LTMCU XBTN410 VJD SND TMS V11M $ Price 265.00 300.00 161.00
16-94
I12
Discount Schedule
Protection Components
www.schneider-electric.us
LT6CT4001
DA1TT
Configuration with PowerSuite The TeSys T configurator is incorporated in the PowerSuite software application, versions 2.6 and higher. PowerSuite software allows configuration, commissioning and maintenance of motor starters protected by a TeSys T controller. A library containing predefined motor control mode functions is available in order to:
allow standardization avoid errors reduce motor starter setup times easily adapt these predefined motor control mode functions to the specific needs of your applications create new functions
The functions thus defined can be saved and used to build your function library for future applications. To create special functions, a logic editor is incorporated in the configurator and allows a choice of 2 programming languages:
TXSCUSB485
250.00
TeSys T and SMS PowerLogic: TeSys T is integrated in PowerLogic SMS Version 4.0. and will address energy management needs by fully utilizing the TeSys T power/energy management features. For more information on PowerLogic products, see Power Monitor Control Section 4.
I12
Discount Schedule
16-95
16
Interface for USB port (for use with cable W3A8106) Length: 1.8 m USB serial port cable for connecting a 1 USB/Serial Port Cable TeSys T controller to your PC
SR2CBL06
156.00
Protection Components
Shielded twisted pair cables, UL and CA 22.1 approved Cables fitted with 2 x RJ45 connectors for connection to terminal equipment Straight 2 (7) 5 (16) 12 (39) 40 (131) 80 (263) 0.3 (1) 1 (3) 3 (10) 0.3 (1) 1 (3) 490NTW00002U 490NTW00005U 490NTW00012U 490NTW00040U 490NTW00080U VW3A8306R03 VW3A8306R10 VW3A8306R30 VW3A8306TF03 VW3A8306TF10 VW3A8306R 48.00 57.00 75.00 159.00 258.00 20.00 25.00 30.00 75.00 85.00 N/A
Elbowed (90) Straight Elbowed (90) SUB-D 9-pin connector for connection to PC or diagnostic tool
For DeviceNet connection Cables 50 (164) 100 (328) 300 (984) TSXCANCA50 TSXCANCA100 TSXCANCA300 112.00 467.00 1323.00
For Profibus DP connection Cables Connectors With line terminator Without line terminator With line terminator and terminal port 100 (328) 400 (1313) TSXPBSCA100 TSXPBSCA400 490NAD01103 490NAD01104 490NAD01105 826.00 2990.00 73.00 62.00 101.00
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-96
I12
Discount Schedule
Protection Components
www.schneider-electric.us
LTMR controllers
122.5 5.2 91
30.2
30.2
61
23
117
92
61
50
a b 140 mm with RJ45 connector for connection to expansion module and to network, 166 mm with Profibus DP/CANopen connector. Leave a gap around the device of: 9 mm at 45 C, 9 to 40 mm from 45 to 50 C, 40 mm at 60 C. HMI Terminal XBTN410
35 107
42
70
45 132
25
35 95
25 5
2,5
42,5
42,5
6
c d
I12
Discount Schedule
16-97
16
2,5
104 mm with mounting clips (supplied with the product). 58 mm with SUB-D 25-pin elbowed cable XBTZ9680 for Twido, TSX Micro and Premium PLCs or XBTZ998 for Advantys STB distributed I/O system. 104 mm with SUB-D 25-pin cable XBTZ68/Z9681 for Twido, TSX Micro and Premium PLCs
10 10 20
30
74
Bimetallic
Class 9065 / Refer to Catalog 9065CT9701
www.schneider-electric.us
Bimetallic thermal overload relays feature Class 20 protection with automatic reset or hand reset and a trip-free mechanism. There are ambient temperature-compensated versions. Note that thermal units are not included in the shown prices. Standard trip thermal units are $21.50 each. Table 16.289: For Separate MountingBimetallic600 V Maximum AC or DCa
Description Size Maximum Full Load Current (Amperes) Open Type $ Price Bracket Kit for Terminal Block Channel Mounting Type Price Number of Thermal Units Required
Single Pole Construction (One N.C. Contact) 00, 0, 1 25 DA2 107.00 2 60 GA2 149.00 Compensated 1 3 100 HA2 261.00 4 180 JA2 306.00 Three Pole Construction (One Common SPDT Contact on Type S) Non1 26 SEO6B2 392.00 SM2 35.60 3 Compensated 2 45 SEO9B2 441.00 SM2 35.60 1 26 SEO6B 441.00 SM2 35.60 Ambient 3 2 45 SEO9B 441.00 SM2 35.60 TemperatureCompensated For additional selections see International Control Products. a Maximum power contact rating for separate mounting overload relays. Maximum control circuit contact rating for Type S versions is 600 Vac only.
Table 16.290: Replacement Overload Relay for Square D Class 8536 Bimetallic Overload Relay on an Existing Starter
Locate Class 8536 Starter in this Column NEMA Size Number of Poles Any Any Any 3 3 3 3 Y59c Order Class 9065 Overload Relay from this Column Form Bb B1b B2b Bb B1b B2b Bb B1b B2b Y59c Type SDO6B SDO5B1 SDO6B2 SDO6B SDO5B1 SDO6B2 SDO9B SDO8B1 SDO9B2 26005-11000 SHA01Y59 26005-11500 SJA01Y59 $ Price 441.00 392.00 392.00 441.00 392.00 392.00 512.00 464.00 464.00 243.00 1089.00 306.00 1431.00 Number of Thermal Units Required 3 2 3 3 2 3 3 2 3 1 3 1 3
Type
Series
0 1 2
SB SC SD
A&B A&B A A A B A A B
3e
SE
4e
SF
b c d e
B2d SEO6B2 392.00 3 5 SG A&B 3 Bd SEO6B 441.00 3 B SEO6B 441.00 3 6 SH A&B 3 B2 SEO6B2 392.00 3 B indicates ambient temperature-compensated bimetallic overload relay. B1 indicates single phase non-ambient temperature compensated bimetallic overload relay. B2 indicates polyphase non-ambient temperature compensated bimetallic overload relay. Y59 indicates single phase ambient temperature compensated bimetallic overload relay. B2Y500 indicates bimetallic overload relay with current transformer sensing. BY500 indicates ambient temperature compensated bimetallic overload relay with current transformer sensing. This part number does not include the current transformer assembly. Non-compensated Size 3 & 4 OLRs are no longer available. Select an ambient compensated OLR from appropriate table above.
Table 16.291: Replacement Overload Relay for Square D Class 8940 Pump Panel with IEC Style Bi-metallic Overload Relays Mounted on Current Transformers
Number of Form Series Typef Poles 40A-63A 3 B12 B TJF40 63A-100A 3 B12 B TJF63 100A-160A 3 B12 B TJF100 160A-250A 3 B12 B TJF160 f A retro-fit reset kit is required for pre-series B pump panels. See page 16-101 for selection. AMP Range $ Price 428.00 428.00 468.00 468.00
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-98
CP1
Discount Schedule
Approximate Dimensions
Table 16.292: Melting Alloy Type NEMA Style
Dimensions (IN) Type A SEO5 SEO8 SEO12 SEO15 35/16 35/16 B 519/32 631/32 C D E F G H I 25/16 25/16 39/16 39/16 J 1/2 1/2 3/4 3/4 K 1/2 1/2 9/16 9/16 L 1/2 1/8 7/8 7/8 M 27/32 27/32 N 1 1 O 1-3/8 1-3/8 2 2 P #10 #10 #1/4 #1/4 33215/32 31/32 17/32 13/16 7/32 11/16 3215/32 31/32 3-1/2 13/16 3/16 11/16 9/16 5-3/4 9/16 5-3/4 55/16 55/16 4-3/4 9/32 4-3/4 9/32 17/16 2-1/8 Shipping Weight (lbs.) 1 1-1/4 3
M K J L N O C D E F G H
A I B
Type SEO
.28 7.1 1.34 34 .69 17.5 0.66 16.8 0.5 12.7 (2) 8-32 Mtg Screws
0.22 5.6
0.31 7.9
RESET 1.38 35 Over Thermal Unit
.41 10.4
.25 6.4
.28 7
2.0 50.8
.44 11
4.75 120.7
6.19 157.23
.6 15.2
0.38 9.65
Reset Travel
3.25 82.5
Tripped
Reset Travel
Tripped
Reset Travel
0.94 23.8 (2) 5 Dia 16 Locating Dowels 1.0 25.4 1.0 25.4 2.75 69.85 0.125 3.18
3.25 82.5
Dimensions shown for Types TO1 and UO1 do not apply when Form Y342 or Y34 is supplied.
1.41 36
0.38 10
4.94 125
1.41 36
Alarm
O.L. C om
.
Terminal Connections 2.63 67
Tripped
0.22 5.59
Left Hand
1.00 25
Right Hand
Dual Dim
In. mm
1.00 25
Right Hand
Left Hand
0.47 12
16-99
16
Approximate Dimensions
Bimetallic Overload Relays
.50 13 3.75 95 2.81 71 .50 13 3.50 89 2.81 71
3.59 91 2.30 58
Reset
3.34 85 2.30 58
Reset
.80 20 .06 2 1.00 25 .31 8 .31 Reset Travel 8 Prov. for (4) #10 Mtg. Screws .06 2 1.00 25
.89 23
3.94 100
.89 23
3.94 100
Table 16.293:
Class Ampere 9065 Rating DA GA HA JA 25 60 100 180 Outline Dimensions A 3-1/2 4-7/8 4-7/8 5-15/16 B 7/8 7/8 1-1/4 1-1/4 C 3-3/16 3-3/16 3-3/16 3-3/16 Mtg. Dimensions D 3 3 3-1/2 3-1/2 E 1/2 1/2 1/16 1/2 Reset Dimensions K 3/8 3/8 1/2 3/16 L 1/8 1/8 1/8 1/8 Mtg. Approx. Screw Max. Wire Size Shipping Weight (lbs) G 10 10 10 10 8 1 00 250 MCM 2 2 3 4
J A D
G (2 Holes)
K E B
L Reset Travel C
.31 8
RESET
2.23 57
2.69 68
.89 23
.27 7 .28 7
NEMA Size 00B, 00C, 0, and 1 Devices Note: NEMA Size 00B and 00C are not actual NEMA sizes. These designations are used to differentiate the lower FLA of these devices from the NEMA size 00 Motor Logic Solid State Overload Relay.
4.28 109
3.91 99
1.70 1.84 43 47
RESET
2.19 56 3.24 82
3.51 89
16
5.32 135 3.25 83
Size 2 Devices
.29 7
1.50 38
.29 7
1.50 38
3.56 90
.31 8
3.56 90
.31 8
.24 6 Reset Travel .38 10 1.57 40 1.57 40 5.33 135 3.80 97 .32 8 .38 10 1.57 40 1.57 40 5.33 135
Size 3 Devices
Size 4 Devices
2009 Schneider Electric All Rights Reserved
16-100
Approximate Dimensions
Class 9065 / Refer to Catalog 9065CT9701
7.38 8.25
210
PWR
187
31161-184-51 SERIES B
A600 P300
AC 3 Ph
50-60HZ TRIP
90
5.88
149
SQUARE D COMPANY
LISTEDIND.CONT.EQ.A159
MADE IN USA
2.25
57
1.18
30
2.20
56
4.70
119
3.10
79
5.05 2.14
54 128
2.03
52
2.65
67
2.28
58
3.05
77
.70
18
3.60
91
.25 3.85
98 6
.20
5
.34
9
4.37
111
Type RB1
Type W1
Table 16.294:
Where Used Type of Enclosure NEMA 1, 12 NEMA 1, 12 NEMA 4 NEMA 1 with slip-on covers NEMA 3R Reset Mechanism Kit Description With 1 Rod With 2 Rods With 3 Rods Size 0 and 1 Size 2 W1 is a boot only and must be used with RA or RB Kit listed above Size 00, 0 and 1 Size 2 Size 3 Reset for use with 9065TJF Series B OLR Type RA1 RA2 RA3 RB1 RB2 W1 SC1 SD1 SE1 RTJF $ Price 57.00 71.00 86.00 42.80 42.80 28.70 7.20 12.00 14.30 42.80
OEM Kit for commercial enclosures Replacement on 8538, 8539 starters On commercial enclosures or Type S combination starters Replacement on Class 8536 Type S starters
Type SC1
CP1
Discount Schedule
16-101
16
Separate Enclosures
Separate enclosures can be used with open style devices for field assembly of enclosed controls. These enclosures, plus the open style components, are equivalent to a factory-assembled device. Separate enclosures are to be used only with the equipment listed below:
NEMA 4 and 12 Class 9991 separate enclosures for Type S devices are supplied as standard with closing plates. See selection chart below for specific number of closing plates on Various enclosures. For applications requiring enclosures without closing plates, contact your nearest Square D/Schneider Electric sales office. NEMA 3R enclosures for field assembly of equipment for outdoor applications are provided with three closing plates, a reset mechanism and predrilled panel as standard. For conduit connection to the top of these enclosures, select watertight hubs from listing on Digest page 3-9 in accordance with applicable code requirements. Square Ds NEMA 12 enclosures can also be modified for outdoor use. For details, refer to NEMA 12 enclosure modification information on page 16-104. NOTE: Not for use in highcorrosive outdoor locations or sea coast environments. NEMA 4X enclosures for Type S devices, Sizes 02 and 3060 Ampere, are provided as standard without closing plates. Cover mounted control units for NEMA 4X separate enclosures are available as a factory modification only.
When closing plates are removed from NEMAs 4, 12 & 3R enclosure covers, the openings can be used for easy installation of Class 9001 Type K or Type SK cover mounted control units. Convenient Class 9999 modification kits containing Class 9001 Type K control kits can be found on page 16-118. Table 16.295:
Enclosure Classification For Use With NEMA 4X Watertight, Dusttight and Corrosion-Resistant Glass-Polyester Type $ Price NEMA 4d Watertight and Dusttight Stainless Steel Number of Closing Plates NEMA 12/3R Dusttight and Driptight Number of Closing Plates NEMA 3R Rainproof, Sleet Resistant, Outdoor Use Type $ Price
Class
Type
$ Price
Type
$ Price
Manual Starters 2510 MBO, MCO MO M1 M1P MW1e 485.00 MW11 485.00 MA1 129.00
Magnetic Contactors SAO, SBO, SCO 00, 0, 1 SCW20 684.00 SCW11 714.00 2 SCA11f 372.00 3 SCH2 372.00 SDO 2 SDW20 1169.00 SDW11 1197.00 2 SDA11f 485.00 3 SDH1 485.00 8502a SEO 3 SEW11 1767.00 3 SEA11f 684.00 3 SEH1 684.00 SFO 4 SFW11 3119.00 3 SFA11f 1853.00 3 SFH1 1853.00 Magnetic Starters SAO, SBO, SCO 00, 0, 1 SCW21 684.00 SCW11 714.00 2 SCA11f 372.00 3 SCH2 372.00 SDO 2 SDW21 1169.00 SDW11 1197.00 2 SDA11f 485.00 3 SDH1 485.00 8536 SEO 3 SEW11c 1767.00 3 SEA11cf 684.00 3 SEH1 684.00 SFO 4 SFW11c 3119.00 3 SFA11cf 1853.00 3 SFH1 1853.00 Lighting Contactors, Non-Combination, Electrically and Mechanically Held LO, LXO 20 Amp SDW20 1107.00 SDW11 1197.00 2 SDA11f 485.00 3 SDH1 485.00 SMO 30 Amp SCW20b 684.00 SCW11 714.00 2 SCA11f 372.00 3 SCH2 372.00 8903a SPO 60 Amp SCW20b 1169.00 SDW11 1197.00 2 SDA11f 485.00 3 SDH1 485.00 SQO 100 Amp SEW11c 1767.00 3 SEA11cf 684.00 3 SEH1 684.00 SVO 200 Amp SFH1 1853.00 Reversing and Two Speed Horizontally Arranged Contactors and Starters 8702a SBO, SCO 0, 1 SCW12 1182.00 SCA12f 527.00 3 3 8736 SDO 2 SDW12 1754.00 SDA12f 728.00 8810 SBO & SCO 0, 1 SCW13 1610.00 3 SCA13f 714.00 3 a For contactors, replace reset assembly with proper closing plate; for NEMA 4 use Class 9001 Type K52, for NEMAs 3R and 12 use Class 9001 Type K51. Class 9991 Types SCW20 and SDW20 are designed for contactors only, reset closing plates not required. b For electrically held devices only. c Enclosure suitable for starter with melting alloy and solid state overload relays only. d The standard cabinet has a brushed finish. e Type MBO, Size MO only. f NEMA 12 enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 16-104 for more information.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Type SCH2 NEMA 3R Enclosure
16-102
CP1
Discount Schedule
Separate Enclosures
Class 9991
www.schneider-electric.us
Class
(with pullbox and plaster adjustment) (without pullbox but with mounting strap)
2510
Magnetic Contactors SBO & 0, 1 SCO 8502a SDO 2 SEO 3 Magnetic Starters 8536
SCF11
71.00 SCF1
86.00
SDF11 171.00 SDF12 386.00 SDF2 99.00 SDF1 116.00 SEF11 882.00 (Enclosure Complete)
SBO & 0, 1 SCF11 57.00 SCF12 201.00 SCF2 71.00 SCF1 86.00 SCO SDO 2 SDF11 171.00 SDF12 386.00 SDF2 99.00 SDF1 86.00 Lighting Contactors Non-Combination Electrically and Mechanically Held LO, LXO 20 Amp SDF13 171.00 SDF2 99.00 SDF1 86.00 SMO 14 30 Amp SCF11 57.00 SCF2 71.00 SCF1 86.00 SMO 1013 30 Amp SCF13 201.00 SCF2 71.00 SCF1 86.00 8903a SPO 14 60 Amp SDF11 171.00 SDF2 99.00 SDF1 86.00 SPO 1013 60 Amp SDF13 171.00 SDF2 99.00 SDF1 86.00 SQO 113 100 Amp SEF11 882.00 (Enclosure Complete) a For contactors, replace reset assembly with proper closing plate. For Flush Mounting use Class 9999 Type SG2 except for Class 9991 Type SDF11 which requires a Class 9001 Type K51 or K11 closing plate. Class 9991 Types SEF11 and LF1 are designed for contactors only, reset closing plates not required. b The standard cabinet has a brushed finish.
CP1
CP2
Discount Schedule
16-103
16
Flush Mounting Starter With Pull Box and Mounting Strap Having Plaster Adjustment Feature
SAO, SBO, 24 SCG7 57.00 SCO SDO 24 SDG7 143.00 8502 SEO 24 SEG7 287.00 SFO 24 SFG8 599.00 SAO, SBO, 24 SCG8 57.00 SCO SDO 24 SDG8 143.00 8536 SEO 24 SEG8d 287.00 SFO 24 SFG8d 599.00 SGO 3 SGG8dg 1241.00 SAO, SBO, SCO All SCG9e 171.00 8702, 8736 SDO All SDG9e 372.00 LO, LXO All LXG1h 143.00 SMO All SCG7f 57.00 8903 SPO All SDG7f 143.00 SQO All SFG8 599.00 SVO All SFG4 1259.00 DP 12 DPG1 78.00 DPA12, 13, 22, 23, 23 DPG1 78.00 32, 33, 42, 43 DPA14, 24, 34, 44, 24 DPG2 99.00 52, 53 8910 DPA62, 63 23 DPG3 143.00 DPA72, 73, 92, 93, 23 DPG4 287.00 122, 123 H, J, K, L & M All UE6 99.00 DPSO13, 23, 33, 43 3 DPSG1 59.00 8911 DPSO53 3 DPSG2 102.00 DPSO63, 73, 93 3 SEG8 287.00 AO All UE6 99.00 (Single Head) 9050 HO All UE6 99.00 EO51, EO61, EO71, K750, SDG4 458.00 K1000 EO2, EO3, EO4, EO15, EO16 9070 EO18, EO19, LG1 143.00 T75, T100, T150, T200, T250, T300, T350, T500 EO1, EO17, T50 UE7 99.00 c CP2 Discount Schedule, not CP1. d Enclosure suitable for starter with melting alloy or solid state overload relay only. e For horizontally arranged Class 8702 contactors replace reset assembly with a Class 9001 Type K51 closing plate. f For electrically held contactors only. See page 16-104 for mechanically held contactors. g Series B starter enclosure. h If cover mounted control units are required, select oversized enclosure listed on page 16-104.
Class
Type
No. of Poles
Type
VA
Magnetic Contactors and Starters SAO, 13 d SBO 00, 0 & 1 SCG1 270.00 8502 & 45 & SCO 8536 SDO 2 25 SDG4 458.00 Lighting Contactors, Non-Combination LO, LXO 8903 SMOf 20 A 30 A All
a b c d e f
13 SDG3 399.00 SDW3 1169.00 SDA3 45 T100 100 VA T150 T300 60 A 25 SPOf For mounting in SCG1 enclosure, a Class 9991 Type S1 adapter bracket is also required $44.00 NEMA 12 modified for outdoor use (see below). For price list and complete description, see the Class 9070 section. Note: Class 9991 Type SCG1 enclosure is provided with a Class 9999 Type SF4 fuse block as standard. For contactors (Class 8502), a separate closing plate is provided with each enclosure to replace the reset mechanism with the exception of Class 9991 Type SCG1 which requires a separate reset closing plate Class 9999 Type SG2 $14.30 The standard cabinet has a brushed finish. Mechanically held.
NEMA 12/3R Enclosures Modified for Outdoor Applications (not to be used in salt air or corrosive environments)
Type SCA11 NEMA 12 Enclosure
Field Modifications for NEMA 3 dusttight, raintight and sleet resistant outdoor applications are as follows: Watertight conduit hubs or equivalent provision for watertight connection at the conduit entrance shall be used. Field Modifications for NEMA 3R rainproof and sleet resistant outdoor applications are as follows:
1. 2. Watertight conduit hubs or equivalent provision for watertight connection at the conduit entrance, when the conduit enters at a level higher than the lowest live part, shall be used. Drain holes of 1/8 inch diameter shall be added to the bottom of the enclosure.
Class 9001 Type K oiltight/watertight control units can be easily installed in NEMAs 4, 12, and oversized NEMA 1 separate enclosures provided with closing plates. When installing control units simply remove the closing plates and install the proper Class 9001 Type K components. Convenient control unit kits complete with assembled and pre-wired operators for quick installation are available as Class 9999 user modification kits. See Table 16.300 for contents of each control unit kit. Class 9001 Type SK NEMA 4X corrosion resistant control units may be used as an alternate. Table 16.300: Control Unit Selection Table
Class 9999 Type Kit Contents Control Function Class & Type 1-9001 KR1B 1-9001 KR1R 1-9001 KN201 1-9001 KN202 2-9001 KA1 1-9001 KS43B 1-9001 KN260 1-9001 KA1 1-9001 KP1R31 Description Start Operator Stop Operator Start Legend Plate Stop Legend Plate Contact Block Selector Operator Switch Hand-Off-Auto Legend Plate Contact Block Red Pilot Light
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
SA3
SC8 SP28R
16-104
CP1
Discount Schedule
Separate Enclosures
www.schneider-electric.us
Approximate Dimensions
Class 9991
SCG8 DPG2 DPSG1 SDG7 SDG8 DPG3 DPSG2 SEG7 SEG8 DPG4
8536 8910 8911 8903 8502 8536 8910 8911 8502 8536 8911 8910 8502 8536
6.03 153 1 (4)1/4 7.81 198 12.69 322 6.31 160 8.00 203 8.38 213 8.99 228 8.60 218 1.25 32 1.25 32 22.31 567 1.42 36 .44 11 34 1.09 28 10.50 267 1.09 28 1.09 28 5.63 143 5.75 146 1.09 28 5.63 143 8
(4)3/8
11.44 291
21.81 554
1.53 39
18.75 476
1.53 39
1.53 39
8.38 213
7.75 197
1.53 39
8.38 213
23
SFO 4 All SFO 4 All 11.25 25.15 2 (4)7/16 286 639 SQO 8903 100 A All (E.H. & M.H.) SBO, 8702a 0&1 SCO 11.88 11.88 All 2 (4)5/16 SCG9 302 302 ETBC20, 8922 ETBC36 8702a SCO 2 14.88 14.13 SDG9 All 2 (4)5/16 378 359 8922 ETBC60 a Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 02. SFG8
1.06 27 1.06 27
1.06 27 1.06 27
1.06 27 1.06 27
.31 8 .31 8
16
24
8903 8502
7.56 192 2 (4)5/16 14.88 378 14.13 359 12.75 324 1.06 27 1.06 27 12.00 305 1.06 27 .31 8
SDG4
21
SCG1
8536 8903
H A D K L K E Pilot Light F B B
RESET RESET
C J
G G
G H I H E D F C
Figure 1
Figure 2
Figure 3
16-105
16
Separate Enclosures
Approximate Dimensions
Class 9991
www.schneider-electric.us
XO 4.87 7.79 7.53 3.50 6.38 XDO 124 198 191 89 162 EO1, EO17 9070 T25, & T50 EO2, EO3, EO4, EO15, EO16, EO18, EO19 7.53 9.78 5.91 6.13 8.38 LG1 9070 T75, T100, T150, 191 248 150 156 213 T200, T250, T300, T350, & T500 a Class 9991 UE1 has only (3) -H diameter mounting holes; 2 in the bottom as shown and 1 centered at the top. b Class 9999 LG1 has three knockouts, top and bottom. 8501 UE7
1.31 33
1.88 48
#10
1/23/4 in.
1.31 33
1.88 48
9/32 in.
1/23/41 in. b
10
SCH2
SEH1
12.63 321
25.30 643
8.62 219
1.39 35
1.44 37
10.00 254
20.60 523
2.61 66
2.19 56
2.08 53
2.62 66
19.78 502
1.31 33
2.31 59
2.69 68
6.38 162
1/2 3/4
All 2-3
SFH1
12.63 321
40.30 1024
9.12 232
1.39 35
1.44 37
10.00 254
35.50 902
2.61 66
2.19 56
2.08 53
2.62 66
20.28 515
1.31 33
2.31 59
2.69 68
6.38 162
1/2 3/4
A D1 N G1
A
D2
C P
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
M Y
X K L
F G 2
H1 H2
Figure 5 Figure 4
16-106
Separate Enclosures
www.schneider-electric.us
Approximate Dimensions
Class 9991
SDW21
SCW11
12
SDW11
3/4 in.
1-1/2 in.
18
SFW11
A E
D G B
A E
F C C
Figure 6
Figure 7
16-107
16
Separate Enclosures
Class 9991
www.schneider-electric.us
Approximate Dimensions
Table 16.308: NEMA 12/3RDusttight and Driptight Enclosures (Standard)
Class 9991 Type SCA11 For Use With Class 8502 8536 8903 8502 8536 8903 8903 8903 8502 8536 8536 8502 Type SBO, SCO SBO, SCO SMO SDO SDO LO, LXO SPO SQO SEO SEO SFO SFO No. of Poles 0, 1 All 0, 1 All 30 Amp All 2 All 2 All 20 Amp All 60 Amp All 100 Amp All 3 All 3 All 4 All Size 4 All A 6.38 162 B 8.53 217 Dimensions (see Figure 8) C 12.75 324 D 1.56 40 E 3.25 83 F 12.00 305 G .38 10 H 3.56 90 I 12.50 318 J .31 8 Weight (lbs.)
A E
F
10
SDA11
15
SEA11
SFA11
Figure 8
A E
F
18 19 24 27
I
All 27
SDA4
Figure 9
C
17
H E
H G
10
10.94 278
5.13 130
.38 10 .18 5
17
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Figure 10
48
SEF11
16-108
Factory installed modifications are available for the classes of control equipment listed in the respective tables. Prices shown are additions to standard equipment prices and are not to be used as separate selling prices. Kits are also available for many field modifications and normal parts replacement on most control items. Refer to Classes 9998 and 9999 for complete listings. Standard equipment dimensions and enclosure construction may not apply when certain special features are added. Such cases should be referred to the factory with complete description when accurate dimensions are required. NOTE: If UL label is required, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733). Some Forms are not UL Listed. Table 16.311: Full Voltage Starters
Factory Modifications Push Buttons a Start-Stop PILOT DEVICES IN COVER Full Voltage NonReversing Controllers Only Classes 8502 8536 8538 8539 Start-Stop (maintained contact)e Start-Stop push button and Hand-Off-Auto selector switch On-Off Single Oiltight Pushbutton (specify marking) Selector Switches Hand-Off-Auto On-Off NON-STANDARD markings for Pilot Devices Addition of padlock attachment to Class 9001 operators Pilot Lights (specify color/type) b See Table 16.312 below. With Operating Interlock: Add price of each interlock per light Push Buttons a Forward-Reverse-Stop High-Low-Stop PILOT DEVICES IN COVER Full Voltage Reversing and Multi-Speed Controllers Only Classes 8702 8736 8738 8739 8810 8811 8812 Fast-Off-Slow High-Low push button and Hand-Off-Auto selector Single Oiltight Pushbutton (specify marking) Selector Switches Hand-Off-Auto On-Off High-Off-Low Forward-Off-Reverse High-Low and Hand-Off-Auto Slow-Fast Forward-Reverse High-Low-Off-Auto 1g, 4, 4X, 12 7&9 1g, 4, 4X 7&9 1, 4, 12 1, 4, 4X, 12 7&9 1, 4, 12 1, 4, 4X, 12 1, 4, 4X, 12 1, 4, 12 C C C6 C6 C7 C14 CC17 C19 C20 C25 224.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 336.00 599.00 336.00 599.00 336.00 336.00 599.00 671.00 336.00 336.00 671.00 1g, 3R, 4, 4X, 12 7&9 1g, 3R, 4, 4X, 12 7&9 1, 3R, 4, 12 1, 3R, 4, 12 C C C6 C6 G12d G122 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 336.00 599.00 336.00 599.00 30.00 44.00 1g, 3R, 4, 4X, 12 7&9 1g, 3R, 4, 4X, 12 1g, 3R, 4, 4X, 12 1g, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 A A A16 AC A3 A11 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 336.00 599.00 378.00 671.00 336.00 336.00 Enclosure Type Form NEMA Size 00 0 1 2 3 4 5 6 7
1, 3R, 4, 4X, 12
Xf
158.00
158.00
158.00
158.00
158.00
158.00
158.00
158.00
158.00
1, 4, 4X, 12 7, 9 1, 4, 12 1, 4, 12 1, 4, 12 1, 4, 4X, 12
A1 A1 A2 A9 A10C A11
570.00 570.00 570.00 570.00 570.00 570.00 570.00 570.00 1017.00 1017.00 1017.00 1017.00 1017.00 1017.00 1017.00 1017.00 570.00 570.00 570.00 570.00 570.00 570.00 570.00 570.00 570.00 671.00 336.00 570.00 671.00 336.00 570.00 671.00 336.00 570.00 671.00 336.00 570.00 671.00 336.00 570.00 671.00 336.00 570.00 671.00 336.00 570.00 671.00 336.00
a b c d e f g
NON-STANDARD markings for Pilot Devices Any G12d 30.00 30.00 30.00 30.00 30.00 30.00 30.00 30.00 Pilot Lights b With Operating Interlock: 1, 4, 4X, 12 Xf 158.00 158.00 158.00 158.00 158.00 158.00 158.00 158.00 158.00 Add price of each interlock per light All push buttons are momentary contact unless specified otherwise. Indicate pilot light color as Form P1 (red) or Form P2 (green), etc. as shown in the table below. Unless otherwise requested, standard practice is to wire red pilot light to indicate device is energized. No additional auxiliary contact is required. Also, standard practice is to wire green pilot light to indicate device is de-energized. An additional normally closed auxiliary contact is supplied. A wiring diagram must be supplied for other pilot light colors and/or arrangements. Pilot lights available at 120 to 600 V only. Specify marking and/or Class 9001 Type KN or Type SKN legend plate required. Specify appropriate Class 9001 Type K or SK operator required. To determine the maximum number of auxiliary contacts which can be added to each Type S device and for the appropriate X Form, refer to the tables in the Class 8536 section on page 16-14 (for non-reversing single-speed devices) or the Class 8736 section on page 16-51 (for reversing or two-speed devices). For Class 8600 Reduced Voltage controllers, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733). Various form combinations selected may force the use of a larger enclosure.
CP1
Discount Schedule
16-109
16
Table 16.316:
AC-OPERATED DEVICES With Control Transformers Voltage 60 Hz (PrimarySecondary) 12012k 12024k 208120 24024k 240120 277120 48024k 480120 480240 600120 Specify 12 V coils are not available on Sizes 37. 24 V coils are not available on Sizes 47. Code V88 V89 V84 V82 V80 V85 V83 V81 V87 V86 V99
M10
See Below
Table 16.315:
Form M10 i j NEMA Sizei 00j 0j 1 338.00 2 450.00 3 720.00 4 1260.00 5 3015.00 6 4725.00 k
Not available for NEMA Size 7. Cannot be used with Marine controls.
To order, select the desired device with the appropriate transformer Form designation. Then convert the previously selected voltage code (V ) to reflect the desired primary/secondary voltage for the transformer. The secondary voltage should equal the previously selected coil voltage of the device. Example: You have previously selected a Class 8536SDG1V02S. V02S means that you need a coil voltage of 120-60/110-50 wired for separate control. You would like to add Form FF4T with the transformer voltages being 480 volt primary, 120 volt secondary with Solid State Overload Relay Protection Class 20 Trip Class (H20). The new and complete class, type, voltage code and form number will be:
Class Type Voltage Code Form l 8536 SDG1 V81 FF4H20T Form numbers should always be shown in alphabetical order. Each letter indicates the beginning of a new form and may be followed by one or more numbers.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-110
CP1
Discount Schedule
For Full Voltage Contactors & Starters and Solid State Overload Relays
Class 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 8810, 8811 and 8812
Any
B1
35.60
35.60
35.60
B1 B2 B2 B2
35.60 35.60
35.60 35.60
35.60 35.60
35.60
35.60
Overload Relays
B Y59 B B
64.00
64.00
64.00
64.00
a b c
Overload RelaysGeneral Any Y81 Modify Size 3 Type SE starters with melting alloy overload relays to accept Type FB quick trip or SB slow trip thermal units Substitute 9999 SO4 isolated alarm contact (N.O.) Any Y342 179.00 179.00 179.00 on melting alloy overload relay Substitute 9999 SO5 isolated alarm contact (N.C.) Any Y344 179.00 179.00 179.00 on melting alloy overload relay Size 7 uses a solid state overload relay as standard. See Class 8536 for complete details. Single phase bimetallic overload relays for Type S Sizes 02 require two (2) thermal units per starter. For Classes 8736, 8738 and 8739 Type SG, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733).
a a
Table 16.318: Classes 8536, 8538, 8539, 8736, 8738, 8739 and 8810
NEMA Size (Overload Current Range) Factory Modifications Base Unit, Trip Class 10 Base Unit, Trip Class 20 Feature Unit Base Unit, Trip Class 10 Base Unit, Trip Class 20 Feature Unit Form H10 H20 H30 H11 H21 H31 00 39 A MOTOR LOGIC Solid State Overload Relay MOTOR LOGIC Solid State Overload Relay with Auxiliary Contact 64.00 64.00 93.00 122.00 122.00 149.00 0 618 A 64.00 64.00 93.00 122.00 122.00 149.00 1 927 A 64.00 64.00 93.00 122.00 122.00 149.00 2 1545 A 64.00 64.00 102.00 122.00 122.00 161.00 3 3090 A 64.00 64.00 116.00 122.00 122.00 171.00 4 45135 A 64.00 64.00 131.00 122.00 122.00 188.00 5 90270 A 64.00 64.00 215.00 122.00 122.00 270.00 6 180540 A 215.00 270.00 7 Std. 56.00 270810 A
Table 16.319: Special Starter Combinations with MOTOR LOGIC Overload Relay Protection
NEMA Solid State Overload Relay Size Contactor 00C 0 1 2 00B Size 00 d Std 0 d d Std 1 d d d Std d Possible factory starter combinations available. 3 4 NEMA Contactor Size 2 3 4 Solid State Overload Relay Size 00B d n/a n/a 00C d n/a n/a 0 d n/a n/a 1 d n/a n/a 2 Std n/a n/a 3 Std d 4
Std
CP1
Discount Schedule
16-111
16
Table 16.320: MOTOR LOGIC Plus Factory ModificationsForm B For use with Class 8536 (Open Starters)
Factory Modification Form B No modification for 200480 V Add communication module for 200480 V No modification for 600 V Add communication module for 600 V Second Digit Designator 0 2 4 6 First Digit Designator - Starter Packages with MOTOR LOGIC Plus Current Ranges 2 .52.3 A 957.00 171.00 957.00 171.00 3 29 A 957.00 171.00 957.00 171.00 4 627 A 957.00 171.00 957.00 171.00 5 1045 A 957.00 171.00 957.00 171.00 6 2090 A 957.00 171.00 957.00 171.00 7 60135 A 1070.00 171.00 1070.00 171.00 8 120270 A 1070.00 171.00 1070.00 171.00 9 240540 A 1070.00 171.00 1070.00 171.00
Example: Form B 4 2 = MOTOR LOGIC Plus overload relay with a current range of 918 A and factory modifications to add A communication module for 200480 volt applications Table 16.321: Full Voltage Controllers Only
Classes 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 8810, 8811 and 8812 3 4 5 6 Addition of one NEMA Size 1, 30 A single pole N.O. unit Any Y428 287.00 287.00 287.00 b 287.00 287.00 287.00 287.00 Addition of one NEMA Size 1, 30 A single pole N.C. unit Any Y429 287.00 287.00 287.00 b 287.00 287.00 287.00 287.00 Addition of one NEMA Size 1, 30 A double pole N.O./N.O. unit Any Y430 441.00 441.00 441.00 b 441.00 441.00 441.00 441.00 Addition of one NEMA Size 1, 30 A double pole N.C./N.C. unit Any Y434 441.00 441.00 441.00 b 441.00 441.00 441.00 441.00 Addition of one NEMA Size 1, 30 A double pole N.O./N.C. unit Any Y435 441.00 441.00 441.00 b 441.00 441.00 441.00 441.00 Power Poles Addition of one NEMA Size 2 single pole N.O. unit Any Y436 414.00 b 414.00 414.00 414.00 414.00 Addition of one NEMA Size 2 single pole N.C. unit Any Y437 414.00 b 414.00 414.00 414.00 414.00 Addition of one NEMA Size 2 double pole N.O./N.O. unit Any Y438 698.00 b 698.00 698.00 698.00 698.00 Addition of one NEMA Size 2 double pole N.C./N.C. unit Any Y439 698.00 b 698.00 698.00 698.00 698.00 Addition of one NEMA Size 2 double pole N.O./N.C. unit Any Y440 698.00 b 698.00 698.00 698.00 698.00 158.00 158.00 158.00 158.00 158.00 158.00 158.00 158.00 Coil transient suppressor (120 Volt only). Per Coil. Any Y145 Miscellaneous Addition of terminal blocks (specify wired or unwired). 116.00 116.00 116.00 116.00 116.00 116.00 116.00 Wired, per terminal. Each 1, 4, 12 G56a 57.00 57.00 57.00 57.00 57.00 57.00 57.00 Unwired, per terminal. Each 1, 4, 12 G50a a Addition of terminal block type 9080CA or 9080GR6 only. Number of circuits is same as ending of form number. (Ex.: G505 is 5 wire terminal block.) Available in groups of 5 only. b When adding a power pole to a Size 2 device, also specify Form Y118 and add $140.00. Factory Modifications Enclosure Type Form NEMA Size 00 0 1 2 7 287.00 287.00 441.00 441.00 441.00 414.00 414.00 698.00 698.00 698.00 158.00 116.00 57.00
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-112
CP1
Discount Schedule
Pneumatic Timing Relay specify Class 9050 Type A or B 0.1 seconds to 1.0 minuteOn delay 0.1 seconds to 1.0 minuteOff delay 1.0 to 3.0 minuteOn delay 1.0 to 3.0 minuteOff delay
CP1
Discount Schedule
16-113
16
Solid State Timing Relay (specify timing range) and timer 1, 4, 4X, 7, 9, 12 K1070 449.00 449.00 449.00 449.00 449.00 449.00 449.00 449.00 (120 V control required) Motor driven timing relayac 1, 4, 12 K5 2507.00 2507.00 2507.00 2507.00 2507.00 2507.00 2507.00 2507.00 Phase failure and phase reversal relay with time delay option including under and over voltage protection. Addition of a protective relay with options of Phase Failure with Time Delay, Phase Reversal and Under/ 1, 3R, 4, 4X, 7/9, 12 R44 1463.00 1463.00 1463.00 1463.00 1463.00 1463.00 1463.00 1463.00 Over Voltage Protection. (RM3TR1). Both motor voltage and control voltage (V8 voltage code) must be specified with device even if Form S is specified. Form replaces Forms Y444, Y445, Y447, Y448 and Y449. For multispeed controllers: 1, 4, 7, 9, 12 R1 941.00 941.00 941.00 941.00 941.00 941.00 941.00 941.00 Compelling relay (requires motor to be started in low speed) Accelerating relay (provides timed acceleration to selected speed): For Class 8810 1, 4, 7, 9, 12 R2 2195.00 2195.00 2195.00 2195.00 2195.00 2195.00 2195.00 2195.00 For Class 8811 1, 4, 7, 9, 12 R2 4388.00 4388.00 4388.00 4388.00 4388.00 4388.00 4388.00 4388.00 For Class 8812 1, 4, 7, 9, 12 R2 6579.00 6579.00 6579.00 6579.00 6579.00 6579.00 6579.00 6579.00 Decelerating relay (imposes a timing delay during transfer from a higher to a lower speed): For Class 8810 1, 4, 7, 9, 12 R3 2195.00 2195.00 2195.00 2195.00 2195.00 2195.00 2195.00 2195.00 For Class 8811 1, 4, 7, 9, 12 R3 4388.00 4388.00 4388.00 4388.00 4388.00 4388.00 4388.00 4388.00 For Class 8812 1, 4, 7, 9, 12 R3 6579.00 6579.00 6579.00 6579.00 6579.00 6579.00 6579.00 6579.00 Antiplugging timers and relays 1, 4, 7, 9, 12 R10 3846.00 3846.00 3846.00 3846.00 3846.00 3846.00 3846.00 3846.00 Ammeter in cover (includes current transformer if required) 1, 12 G91 1994.00 1994.00 1994.00 1994.00 2820.00 2820.00 2820.00 2820.00 Ammeter and switch with two current transformers 1, 12 G92 4274.00 4274.00 4274.00 4274.00 4274.00 4274.00 4274.00 d Ammeter and switch with three current transformers 1, 12 G93 5270.00 5270.00 5270.00 5270.00 5270.00 5270.00 5270.00 Meters Voltmeter mounted 1, 12 G94 2820.00 2820.00 2820.00 2820.00 2820.00 2820.00 2820.00 and Voltmeter and switch mounted 1, 12 G95 4274.00 4274.00 4274.00 4274.00 4274.00 4274.00 4274.00 Metering Elapsed time meter 1, 12 G97 827.00 827.00 827.00 827.00 827.00 827.00 827.00 827.00 Operation counter 1, 12 G99 1425.00 1425.00 1425.00 1425.00 1425.00 1425.00 1425.00 1425.00 Additional starter (contactor) auxiliary contacts (Specify number of additional N.O. or N.C. contacts required Any Xe 158.00 158.00 158.00 158.00 158.00 158.00 158.00 158.00 per contactor.) Each will be X_ _ (2 digits) i.e. X01 Auxiliary contacts installed on disconnect switch or circuit breaker operating mechanism. Auxiliary Contacts SPDT 1, 4, 4X, 12 Y74 192.00 192.00 192.00 221.00 221.00 413.00 413.00 413.00 DPDT 1, 4, 4X, 12 Y75 386.00 386.00 386.00 441.00 441.00 570.00 570.00 570.00 (Note: Above contacts do not switch with automatic tripping of circuit breaker. If such operation is required, consult your nearest Square D/ Schneider Electric Sales Office.) Space heater with N.C. auxiliary contact 1, 4, 4X, 12 G51 386.00 386.00 684.00 1097.00 1767.00 2622.00 3987.00 3987.00 Function identification plate, with marking as specified Any G11 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 Drain and breather installed 7 & 9h Y41 372.00 372.00 372.00 372.00 372.00 372.00 372.00 Cover gaskets added to NEMA 1 enclosures: For Classes 8538 and 8539 1 Y47 143.00 143.00 Std. Std. Std. Std. For Classes 8738 and 8739 1 Y47 Std. Std. Std. Std. Std. Std. Enclosures For other full voltage controllers 1 Y47 143.00 143.00 215.00 320.00 534.00 1070.00 1710.00 1710.00 For reduced voltage controllers 1 Y47 143.00 143.00 215.00 320.00 534.00 1070.00 1710.00 1710.00 Brushed stainless steel watertight device (add to catalog price of sheet steel watertight device): Class 8606 Y56 1710.00 2138.00 3419.00 4773.00 8546.00 8546.00 Classes 8630 and 8640 Y56 Std. Std. Std. Std. 4773.00 8546.00 8546.00 a If controller has a control transformer, price that transformer with additional capacity for the relay provided. b This adder, used with a NEMA 4X enclosure, applies only to Classes 8538, 8539, 8738, 8739 and 8810 non-reversing. c Specify control and line voltage. d Motor hp and voltage required when placing order. Meters will be panel mounted in NEMA 12 enclosures. e To determine the maximum number of auxiliary contacts which can be added to each Type S device and for the appropriate X Form, refer to the tables in the Class 8536 section on page 16-14 (for non-reversing single-speed devices) or the Class 8736 section on page 16-44 (for reversing or two-speed devices). For Class 8600 Reduced Voltage controllers, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733). f Addition of control relay 18 poles. Number of poles is same as ending of form number. (Ex: R174 = 4-Pole relay). g NEMA 7 & 9 enclosures not available with Class 8600 devices. h Available only on SPIN TOP and cast aluminum NEMA 7/9 enclosures. Auxiliary Relays
Magnetic Coils
Class 9998
www.schneider-electric.us
Table 16.324: Replacement AC Magnet Coils for Magnetic Contactors and Starters (Refer to Table 16.326 on page 16-115 for listing of mechanically held unlatch coils.)
Equipment To Be Serviced Device Size Type Poles 26 Coils for Present Design Magnetic Contactors and Starters Classes 8502, 8536, 8538, 8539, 8606, 8630, 8640, 8647, 8650, 8651, 8702, 8736, 8738, 8739, 8810, 8811, 8812, 8903, 8910c and 8940 (except NP) 8911d 8965e L 30 Amp LX (Latch) 00 00 0, 1, 1P & 30 Amp 2& 60 Amp SAb (Series B) SA (Series A) SB, SC & SM 812 24 612 All All 2&3 SD & SP 4&5 DPA12_, SE, SQ & SYD138 2&3 4&5 All All All 23 23 31104-418 60 50 31063-400 31074-400 31091-400 31091-400 31096-400 31096-320 9998LH 9998L 9998LH 9998SAC 31041-400 31063-409 Coil Prefix or Class and Type 9998L Hz 24 V 23 24 23 24 23 24 23 24 23 20 22 16 17 16 17 16 17 Suffix Number (Complete Coil Number Consists of Prefix or Class and Type Followed by Suffix Number.) 110-115 V 44 44 44 44 a 45 a 42 a 38 a 38 a 38 a 38 a 38 a 09 50 50 120 V 44 45 44 45 44 45 44 45 45 42 43 38 39 38 39 38 39 38 39 38 39 09 10 50 50 208 V 50 52 50 50 52 50 52 48 44 44 44 44 44 15 51 220 V a 53 a 53 53 53 a 54 a 51 a 47 a 47 a 47 a 47 a 47 a 18 52 52 240 V 53 54 53 54 53 54 53 54 54 51 53 47 48 47 48 47 48 47 48 47 48 18 52 52 277 V 55 55 55 55 55 52 49 49 49 49 49 19 53 380 V 60 60 60 60 59 56 57 53 54 53 54 53 54 53 54 53 54 21 22 54 54 440 V 62 62 62 62 a 62 58 60 a 57 a 57 a 57 a 57 a 57 a 24 55 55 480 V 62 63 62 62 63 62 62 60 a 57 57 57 57 58 57 58 24 55 55 550 V 65 65 65 65 a 65 61 62 a 60 a 60 a 60 a 60 a 60 a 29 600 V 65 66 65 65 66 65 65 62 64 60 61 60 61 60 61 60 61 60 61 29 30 Coil VA $ Price Inrush 150 140 180 170 150 140 180 170 165 245 232 311 296 438 429 700 678 1185 1260 1185 1260 2970 2970 1300 1780 1960 a 24 24 a 29 29 1530 1250 Sealed 30 30 35 35 33 27 26 37 36 38 37 46 47 85 89 85 89 212 250 14 48 59 85.00 85.00 85.00 85.00 85.00 98.00 128.00 128.00 254.00 254.00 254.00 354.00 600.00 860.00 860.00
60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50
a b c d e
SF, SV & SYD230 SG, SX & SYD368 Series A 5 & 300 Amp SG, SX & SYD368 Series B 6&7 SH & SJ SY, SZ, SJ 400, 600 (Elect. Held) & 800 SY, SZ, SJ Amp (Mech. Held) Use next higher voltage, 60 Hz coil. Use on Type S Series B devices only. For 8910DPA1x to DPA9x, see page 16-77. For 8911, see page 16-80 For 8965, see page 16-88 and 16-89.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-114
CP10
Discount Schedule
Magnetic Coils
Class 9998 / Refer to Catalog 9065CT9701
www.schneider-electric.us
0
Table 16.326: Replacement AC Magnet Coils for Relays, Timers and Contactors
Equipment To Be Serviced Device Type Poles Coil Prefix or Class and Type Hz 24 V Suffix Number (Complete Coil Number Consists of Prefix or Class and Type Followed by Suffix Number) 110115 V 120 V 208 V 220 V 240 V 277 V 380 V 440 V 480 V 550 V 600 V Coil VA Inrush 148 143 74 68 165 155 $ Price Sealed
60 23 44 51 52 53 55 62 50 24 44 52 53 62 60 W25A W31B W32A W34A W34B W35A W35B W37B W38A A All 2959-S4950 W25B W32A W32B W34B W35A W35B W36A W38A W38B 9050 (Timer) 60 33 54 61 61 63 65 70 72 Bb All 31017-40050 34 55 63 64 72 73 Mechanically Held Unlatch CoilsClasses 8508 and 8903 Note: A latch coil is also used with mechanically held devices. For selection of latch coils for mechanically held relays, refer to page 16-114. 60 23 44 51 53 55 62 LX All 9998LX 50 44 53 62 60 W23B c W30B W33A c W33B W34A c W36B SM, SP All 2959-S13 8903 50 W24B W30B W31B W33B W34B W36A W36B (Lighting SQ, SV, SX, 60 03 c 09 15 c 18 20 c 24 Contactors) All 31096-416 SY, SZ 50 09 18 22 24 60 03 c 09 15 c 18 20 c 24 SJ All 31123-403 50 09 18 22 24 All 9998-Xa
65 W38B W39A 73 75
65 W39A W39B 75 76
23 25 17 17 27 27
65 c W37B c 28 c 28
65 W37B 28 28
25 80 550 2100
Table 16.327: Replacement DC Magnet Coils for Magnetic Relays and Timers
Equipment To Be Serviced Class 8501 (Relays) 9050 (Timers) Type XD XDL XUD C H Poles All All Coil Prefix or Class and Type 9998 XD 9998 XDL 9998 XUD 31018-4004491S1 Suffix Number (Complete Coil Number Consists of Prefix or Class and Type Followed by Suffix Number.) 6V 19 19 19 22 W21 12 V 28 28 28 31 W24 18 V 34 34B 24 V 37 37B 37 40 W27 32 V 40 40B 48 V 46 46B 46 49 W30 64 V 49 49B 72 V 52 52B 90 V 55 55B 110 V 115/ 125 V 220 V 58 58B 58d 61 W34 230/ 250 V 67 67B 67d 70 W37 Coil Burden Watts 18 50 16 14 14 $ Price 168.00 216.00 168.00 312.00 210.00
Table 16.328: Replacement Coil for 8903 Panel Board Lighting Contactors
Replacement Catalog Number $ Price e Solenoid 120 V 9998PBV02 428.00 208 V 9998PBV08 428.00 8903 PB 240/277 V 9998PBV39 428.00 480 V 9998PBV28 428.00 To order an unlatch coil add the letter L to the type number and the letter B to the suffix number. Example: For a 120 V 60 Hz unlatch coil order a Class 9998 Type XL44B. Price for the 9998 Type XL coil series is $114.00. Series C (Double Pole) and Series E (Single Pole). Use next higher voltage, 60 Hz coil. Not dual rated. 125 Vdc or 250 Vdc only. CP1 discount schedule. Class Type
a b c d e
CP10
CP1
Discount Schedule
16-115
16
Class 9998 replacement parts kits are available for servicing Square D relays, contactors, and starters as well as pressure, vacuum, and float switches. Each kit contains the necessary movable and stationary contacts, contact springs (when requiredNEMA Size 3 and above do not include contact springs, and springs are not available), and additional hardware required to service the devices listed below. When servicing devices having more poles than contained in the corresponding kit, it may be necessary to order an additional kit. Table 16.329: Magnetic Contactor and Starter Contact Kits for Present Designs
Equipment To Be Serviced Class SA-, (Series B) 8502 8536 8538 8539 8547 8549 8606 8630 8640 8647 8702 8736 8738 8739 8810 8811 8812 8940 SBSB-, SC-(Power Pole Adder) SCSDSD-(Power Pole Adder) SESFSGSHSJL (Series C) & LX (Series B) SMSPSQSVSX8903 SYSZSJPBM, PBP PBN, PBQ PBM, PBP PBN, PBQ PBR, PBV, PBW PBR, PBV, PBW Type NEMA Size or Amp Rating 00 0 0&1 1 & 1P 1 2 2 3 4 5 6 7 30 Amp 30 Amp 60 Amp 100 Amp 200 Amp 300 Amp 400 Amp 600 Amp 800 Amp 30, 60 A 75, 100 A 30, 60 A 75, 100 A 150, 200, 225 A 150, 200, 225 A No. of Class 9998 Poles Parts Kit in Kit Type No. 3 3 4 1 3 4 3 4 1 2 3 2 3 2 3 2 3 2 3 4 3 4 3 4 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 SJ1 SL2 SL12 SL22 SL3 SL13 SL4 SL14 SL24 SL6 SL7 SL8 SL9 SL10 SL11 SL25 SL26 SL30 SL31 RA5B SL3 SL13 SL4 SL14 SL6 SL7 SL8 SL9 SL10 SL11 SL25 SL26 SL32 SL33 SL30 SL31 PB2 PB3 PB14 PB15 $ Price
90.00 130.00 176.00 63.00 188.00 246.00 370.00 494.00 124.00 442.00 662.00 848.00 1270.00 2104.00 3120.00 3762.00 5606.00 5454.00 8162.00 174.00 188.00 246.00 370.00 494.00 442.00 662.00 848.00 1270.00 2104.00 3120.00 3762.00 5606.00 3762.00 5606.00 5454.00 8162.00 520.00 780.00 850.00 1276.00
Table 16.333: Replacement Control Transformers (150 VA) Class 8502, 8536 Type S Size 6
Voltage 60 Hz 240/480120 208120 277120 600120 120120 240120 50 Hz 220/440110 380110 550110 110110 220110 Part Number 3110451250 3110451252 3110451253 3110451254 3110451251 3110451255 3110451256 $ Price
188.00
Table 16.334: Replacement Control Transformers (200 VA) Class 8502, 8536 Type S Size 7
Voltage 60 Hz 240/480120 208120 277120 600120 120120 240120 50 Hz 220/440110 380110 550110 110110 220110 Part Number 3112350150 3112350152 3112350153 3112350154 3112350151 3112350155 3112350156 $ Price
236.00
Table 16.335: Class 8910, 8911 & 8965 Replacement Contact Kits
Device To Be Serviced Class 9998 3-Pole Type SL27 SL28 SL29 $ Price 662.00 1270.00 3120.00 24.80 22.80 24.80 29.00 52.00 59.00 100.00 132.00 222.00 Class 8910 Class 8911 Class 8965 1-Pole Series Type Type Type Type SYD138 SYD230 SYD368 DPA_20A DPSO1_ DPR1_ B DRC1 DPA_25A DPSO2_ DPR2_ B DRC2 DPA_30A DPSO3_ DPR3_ B DRC3 DPA_40A DPSO4_ DPR4_ B DRC4 DPA_50A DPSO5_ DPR5_ A, B DRC5 DPA_60Ac DPSO6_ DPR6_ A, B DRC6 DPA_75A DPSO7_ A DRC7 DPA_90A DPSO9_ A DRC9 DPA_120A A DRC12 c For class 8911, 60 A starter, use the 9998DRC7 contact kit.
Table 16.330: Magnetic Contactor and Starter Contact Kits for Obsolete Designs
Equipment To Be Serviced Class 8502 & 8536a 8903 a SA-, (Series A) Type NEMA Size 00 No. of Poles in Kit 3 4 Class 9998 Parts Kit Type No. SL2 SL12 $ Price 130.00 176.00
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
LL, L (Series A, B) & 20 4 RA5 174.00 LX (Series A) Amp Includes reversing, two speed and similar devices. Select coil based on NEMA size of basic starter or contactor.
16-116
CP10
Discount Schedule
Starter Accessories
Class 9998, 9999
Refer to page 16-119 for contact ratings. The Type SO1 is also the replacement contact unit for Class 9065 Type M melting alloy overload relays.
Overload Contact Unit Part No. 31102-514-50. Used on Size 5 Starter (8536SGO) with Melting Alloy Overload Relay.
No charge
L1
L2
L1
L2
Jumper strap kits are for use on three-phase manual or magnetic starters with melting alloy overload relays only, where a three-phase starter is used to control a single-phase motor. These kits will include two jumper straps, a wiring diagram showing how to wire a three-phase starter to control a single-phase motor, and single-phase (one thermal unit) selection tables. Table 16.339: Melting Alloy Overload Relay Jumper Strap Kits
T1 T1
T2 T2
T3
Class
For Starter Size 00, 0, 1, 2 and M0 & M1 3,4 5 Type SA, SB, SC, SD and M & T (Manual) SE, SF SG
How to Order
Table 16.340: How to Order
To Order Specify: Catalog Number Class 9998 Type UB01
CP10
CP1
Discount Schedule
16-117
16
Accessories
Class 9999
www.schneider-electric.us
$ StartStart-Stop Hand-Off- Price or 120 V 60 Hz Stop Auto or On-Off On-Off Type Type Type Type
SP28Rc 215.
All SP28Rc 23 SP28Rc 45 SP28Rc All SP28Rc All SP28Rc All SP12R All 6600 SP13R Volts SP14R All 5060 All SP15R Hz All SP28Rc All
215. SP3R 215. SA2 215. SP4R 215. 215. SP5R 215. 215. SP28Rc 215. SA3 215. SP28Rc 215. 215. SP12R 215. 215. SP13R 215. SA2 215. SP14R 215. 215. SP15R 215. 215. SP28Rc 215. SA3
SA10
SA3
SC8
SP28Rc 215.
SP28Rcb SC2 SC22 116. (incandescent) SPL28R (LEDRed) SPL28G SA3 SC8 215. (LEDGreen) SA10e SC22 116. e SA10
SA3a
SC8
SC9
215.
f SM 30 Amp All SP28Rc 215. SP2R 215. SA2a SA10a SC2 SC22 116. 8903 SP 60 Amp All SP28Rc 215. SP3R 215. (ElecSQ 100 Amp All SP28Rc 215. SP28Rc 215. SA3a SA3a SC8 215. trically Held) SJ, SV, 200800 SX All SP28Rc 215. SP28Rc 215. SA3a SA3a SC8 215. Amp SY, SZ a Also requires N.O. auxiliary contact for holding circuit contact when used on Class 8903 electrically held lighting contactors. b Each pilot light kit contains 1 red and 1green lens cap. c The coil voltage must be the same as the pilot light rating. Kit contains one Class 9001 Type KP1R31120V, 60 Hz red pilot light control unit. For other voltages, refer to Class 9001 Type KP. d User made openings are required in order to field install these modification kits on standard 8502, 8536 Type S Sizes 02, and 8903 Sizes 3060 A NEMAs 4 and 12 enclosures. e To mount control unit in a NEMA 1 enclosure, a Class 9999 Type BLX bracket is also required, $35.60. f For Class 8903 (mechanically held contactor) control unit kits, refer to the Class 8903 section, page 16-71. Note: There are no field modification kits available for the polyester enclosures.
SBSF
SBSF SMSV
04 30400
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Class 9999 Type SP2R Pilot Light Kit Class 9999 Type SA2 Push Button Kit Class 9999 Type SC2 Selector Switch Kit Class 9999 Type SA3 Push Button Kit
16-118
CP1
Discount Schedule
Accessories
www.schneider-electric.us
Auxiliary Contacts
Class 9999
External Contacts
Class 9999 Type SX6 external auxiliary contact is supplied as standard for the N.O. holding circuit contact on Type S Sizes 37 starters and contactors. Additional auxiliary contacts can be added to Type S contactors, starters External Single Circuit and lighting contactors. These Auxiliary Contact contacts mount on either side of the basic contactor and are available with convertible or non-convertible contacts. The contacts of the convertible version can be changed from N.O. to N.C. or vice versa in the field. The non-convertible version has fixed contacts, either N.O. or N.C. To determine the number of auxiliary contacts which can be added to each Type S contactor or starter, refer to the Class 8536 or Class 8736 section. See table below for electrical ratings.
Table 16.344: Maximum Ratings for Type S Auxiliary Contacts and Timers
Contact Ratings Class 9999 Type Volts AC 120 or Less 120-600 AC Only (35% Power Factor) Make 30 A 3600 VA Break 3A 360 VA Class 9999 Type SX6-SX10 SX13-SX17 Volts AC 120 or Less 120600 Contact Ratings AC Only (35% Power Factor) Make 60 A 7200 VA Break 6A 720 VA
Continuous 3A 3A
Continuous 10 A 10 A
SX11, SX12
ExternalField Convertible 1-N.O. Contact SX6 86.00 1-N.C. Contact SX7 86.00 SA-SJ 1-N.O. and 1-N.C. Isolated Contacts SX8 116.00 007 1-N.O. Overlapping Contact SX9a 116.00 1-N.C. Overlapping Contact SX10a 116.00 ExternalNon-Convertible 1-N.O. Contact SX13 99.00 1-N.C. Contact SX14 99.00 SA-SJ 007 1-N.O. & 1 N.C. Isolated Contacts SX15 134.00 1-N.O. Overlapping Contact SX16a 134.00 1-N.C. Overlapping Contact SX17a 134.00 InternalNon-Convertible Contact SX11b 99.00 SA-SD 002 1-N.O. Contact 1-N.C. SX12b 99.00 a Types SX9 and SX10 or Types SX16 and SX17 must be used together and mounted on the same side of the contactor. They are suitable for applications where it is necessary for a normally open contact to overlap a normally closed contact. b Types SX11 and SX12 are not applicable for use on NEMA Sizes 3 or larger. Internal contacts can also be used on Class 2510 Types M and T manual starters.
DPR RO2 & RG2 RO10 Form X1 RO11 Form X1 RO3 & RG3 RO10 Form X2 RO11 Form X2 RO5 & RG5 RO12 Form X1 RO13 Form X1 RO6 & RG6 RO12 Form X2 RO13 Form X2
Device To Be Serviced Class 8910 or 8911 Type DPAc DPS Contact Arrangement
1 N.O. D10 24.60 1 N.C. D01 1 N.O./1 N.C. D11 44.30 2 N.O. D20 Type DPA122 and DPA123 use same auxiliary contacts as Type SA-SJ above. (Example: Class 9999 Type SX6).
CP1
Discount Schedule
16-119
16
Table 16.346: Class 8910 and 8911 Definite Purpose Contactors and Starters Auxiliary Contacts
Accessories
Solid State Overload Relay, Motor Logic and Motor Logic Plus
Class 9999, 9065 / Refer to Catalog 9065CT9701
www.schneider-electric.us
DIN Adapter
The DIN adapter provides a method to mount the MOTOR LOGIC overload relay to a 35 mm DIN rail. Table 16.350:
For Use With Parts Kit Description Class & Type NEMA Sizec 9065 SS or SF 00B, 00C, 0, and 1 DIN Adapter Class 9999 Type DA01 $ Price 23.90
Software Kit
Solutions software program allows an IBM PC compatible computer (with Windows 95 or greater) to communicate with a Motor Logic Plus overload relay connected to an RS-485 network using Modbus protocol. Table 16.354:
For Use With Class & Type 8536 SA-SH 9065 SP NEMA Size 16 16 Parts Kit Description Software Kit Class 9999 Type MLPS $ Price 1295.00
Communication Module
This module allows the Motor Logic Plus overload relay to support RS-485 electrical communications standards. Up to 99 Motor Logic Plus overload relays can be controlled and monitored from one remote personal computer. Table 16.355:
For Use With Class & Type 8536 SA-SH 9065 SP NEMA Size 16 16 Parts Kit Description Modbus Communication Module Class 9999 Type MB22 $ Price 171.00
9065 SS or SF 00B, 00C, 0, and 1 Lug-Lug Kit for separate mounting Lug-Extender Kit for 9065 SS or SF 00B, 00C, 0, and 1 retrofitting existing NEMA S starters
16
NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-120
CP1
Discount Schedule
Accessories
Class 9999
www.schneider-electric.us
To add a power pole to a Size 0 and 1 device, remove return springs. When adding a power pole to a Size 2 or 60 A device, a coil change is required. Select a 4- and 5-Pole coil from the coil selection table on page 16-114, or specify Form Y118 as noted in the footnote below. When adding Sizes 02 power pole kits to a Size 37 or 100800 A device, an adapter bracket (9999 SBT1) is required. The Class 9999 Types SB6 through SB15 power pole kits are suitable for copper wire only. Types SB21 through 25 are supplied with lugs suitable for copper and aluminum wire. Table 16.357:
For Use With Power Pole Adder Kit Description Class 9999 Type $ Price
Type
Size
SB, SC & SM 0, 1 & 30 A SB6 158.00 One N.O. power pole SD 2 SB11a adder 287.00 SP 60 A SB21a SB, SC & SM 0, 1 & 30 A SB7 158.00 One N.C. power pole SD 2 SB12a adder 287.00 SP 60 A SB22a SB, SC & SM 0, 1 & 30 A SB8 365.00 One N.O. and one N.C. SB13a SD 2 power pole adder 656.00 SP 60 A SB23a SB, SC & SM 0, 1 & 30 A SB9 365.00 Two N.O. power pole SD 2 SB14a adders 656.00 SP 60 A SB24a SB, SC & SM 0, 1 & 30 A SB10 365.00 Two N.C. power pole SD 2 SB15a adders 656.00 SP 60 A SB25a SE-SJ 3-7 & & Adapter Bracket SBT1 26.10 SQ-SZ & SJ 100-800 A a To order a Size 2 or 60 A power pole kit complete with a new starter coil, specify Form Y118, voltage and frequency and add $140.00 to the price of the kit (e.g., Class 9999 Type SB11 Form Y118, 120 volts, 60 cycles. Priced at $426.00).
CP1
Discount Schedule
16-121
16
Accessories
Class 9999
www.schneider-electric.us
Type SO4
N.O. Isolated Alarm Contact Plus SO4 Standard N.C. Overload Contact 116.00 N.C. Isolated Alarm Contact Plus SO5 Standard N.C. Overload Contact Isolated alarm contacts cannot be added in the field to the Type S Size 5 starter. Current transformers and a Size 1 overload block must be used. For factory installation specify Form Y342. 00-6a SA-SH
Compression Lugs
A Class 9999 Type AL hardware kit is required to install Square D Versa-Crimp compression lugs on Class 8903 Type S, 100800 A lighting contactors. The lugs are suitable for both copper and aluminum wire. One VCEL lug is required for each line or load terminal. Each Class 9999 Type AL hardware kit includes mounting hardware for 3 terminals, line or load side. EXAMPLE: To install compression lugs on a 300 A 3-Pole device, line and load sides, order six VCEL06012H1 lugs and two Class 9999 Type AL11 hardware kits. Table 16.362:
For Use With Rating 100 Amp 200 Amp Class 8903 Type SQ SV VERSA-CRIMP Catalog Number VCEL02114S1 VCEL022516H1 VCEL024516H1 VCEL030516H1 VCEL05012H1 VCEL06012H1 VCEL07512H1 400 Amp or 600 Amp b SY or SZ VCEL06012H2b VCEL07512H2b Wire Range 81/0 Al/Cu 2-Pole 12/0 Al/Cu 3-Pole 2/04/0 Al/Cu 4-Pole 4300 kcmil Al/Cu 2/0500 kcmil Al/Cu 400600 kcmil Al 400500 kcmil Cu 500750 kcmil Al 500 kcmil Cu 400600 kcmil Al 400500 kcmil Cu 500750 kcmil Al 500 kcmil Cu Hardware Kit Class 9999 Type None Required AL132-pole AL143-pole AL154-pole $ Price 143.00 179.00 215.00
300 Amp
SX
AL11
55.00
AL12
107.00
Solid Neutral
The Class 9999 Type SN kit can be used on Class 8903 Type S lighting contactors and other controllers where field addition of a solid neutral is required. Each kit has lugs suitable for both copper and aluminum wire, and mounts with two screws. Table 16.363:
No. of Lugs 4 3 3 (Dual) 2 (Dual) Wire Capacity Per Lug (Cu/Al) 142/0 (1) 4600 MCM or (2) 1/0250 MCM (2) 2600 MCM (2) 6350 MCM Class 9999 Type SN1 SN2 SN3 SN4 $ Price 134.00 392.00 624.00 392.00
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-122
CP1
Discount Schedule
Accessories
www.schneider-electric.us
Mechanical Interlocks
Class 9999
Mechanical Interlock
General: Type S contactors or starters can be mechanically interlocked so that only one device is energized at a time. The mechanical interlock is an interference (non-jamming) type, locking at the beginning of the stroke of any starter or contactor. Type S Sizes 00, 0, 1 and 2The mechanical interlock is mounted on the underside of the reversing baseplate. Two pins extend from the mechanical interlock through openings in the baseplate and engage the contact carrier of each contactor. Two styles of mechanical interlocks are used: one version for three pole contactors, a different version for four or five pole contactors. When adding a power pole to the left-hand side of an existing Size 0, 1, or 2 threepole reversing contactor, a new mechanical interlock must also be installed. When added to the right-hand side only, the power pole will not be mechanically interlocked with the left-hand contactor. Type S Sizes 3 and 4The mechanical interlock is separate from the mounting pan on Sizes 3 and 4. Cams on the mechanical interlocks are operated by the contact carrier of each contactor. The mechanical interlock is attached to the underside of the two contactor baseplates on Sizes 3 and 4. Table 16.366: Mechanical Interlock for Two Contactors The following mechanical interlock kits can be used to interlock 25 pole contactors. Mechanical interlocks for horizontal and vertical arrangement are listed in Various pole arrangements.
Contactor NEMA Size Class 9999 Type $ Price
Type SM1
00, 0, 1 0, 1 0, 1 0, 1 Horizontal Type SM1 for Size 001 Type SM6 for Size 2 Type SM12 for Sizes 3 & 4 Horizontal Type SM2 for Size 0 or 1a Type SM7 for Size 2 Type SM12 for Sizes 3 & 4 Vertical Type SM2 for Size 0 or 1a Type SM10 for Size 2 Type SM11 for Size 3 Type SM13 for Size 4 0, 1
2 2 2 2 2 3 Horizontal Type SM3 for Size 0 or 1 Type SM8 for Size 2 Type SM12 for Sizes 3 & 4
257.00 Vertical Vertical 3, 4 SM12 257.00 Type SM4 for Size 0 or 1 Type SM5 for Size 0 or 1 Type SM9 for Size 2 Type SM11 for Size 3 4 SM13 257.00 Type SM11 for Size 3 Type SM13 for Size 4 Type SM13 for Size 4 The Type SM2 interlock is factory assembled for horizontal mounting, but can easily be converted to vertical mounting. Conversion instructions are included.
Table 16.367: Overload Relay Mounting Bracket Mechanical interlock Types SM1 through SM10 for Sizes 00-2 devices use overload relay mounting brackets to support the overload relay portion of the starter.
Kit Description Bracket for one overload relay used with horizontal mechanical interlocks, Types SM1 through SM10 Bracket for two overload relays used with vertical mechanical interlocks, Types SM2, SM4, SM5, SM9 and SM10 Class 9999 Type SO11 SO12 $ Price 14.30 42.80
Type SM12
CP1
Discount Schedule
16-123
16
Accessories
Class 8538 (Series D and newer), Class 8738 (Series E and newer), and Class 8903 (Series C and newer) Type S non-fusible combination starters and lighting contactors (sizes 02, 30 to 60 amps) can be converted to the fusible type by installing a Class 9422 Fuse Clip Kit. Both fusible and non-fusible combination devices have the same size enclosure in NEMAs 1, 4, and 12 construction, which permits this conversion. The 9422 Fuse Clip Kits contain line and load fuse clips, load base, and fuse pullers. Table 16.369: Class 9422 Replacement Fuse Clip Kits
Class R $ Price Fuse Clip Kits Class & Type Size or 250 V 600 V Ampere Rating Max. Max. 0, 1 & 30 A 30 030 9422TC30a 42.80 RFK03b 0, 1 & 30 A 30 3160 030 9422TC33a 71.00 RFK06b 2 & 60 A 60 3160 030 9422TC33 71.00 RFK06b 2 & 60 A 60 3160 9422TD63 99.00 RFK06Hb When using with a 9422FTCN or FTCF disconnect switch in 8538 or 8738 combination starters, remove and discard metal base plate. No Class Number required Discount Schedule DE1. Device Used on NEMA Class H, K, J, R Fuses Disconnect Ampere Rating Fuse Clip RatingsAmperes $ Price
a b
Table 16.370: Class 9999 Replacement Fuse Clip Kits (8538 Pre-Series D, 8738 Pre-Series E)
Fuse Clip Ratings Type $ Price Type $ Price Amperes Type Size or 250 V 600 V 250 V 600 V 600 V Ampere Rating Max. Max. Max. Max. Max. 030 S1 21.50 030 SR1 35.60 0, 1 & 30 A 30 030 S2 35.60 030 SR2 47.60 030 SJ2 3160 030 S2 35.60 3160 030 SR2 47.60 030 SJ2 3160 030 S2 35.60 3160 030 SR2 47.60 030 SJ2 2 & 60 A 60 3160 S3 50.00 3160 SR3 64.00 3160 SJ3 61100 61100 S4d 144.00 61100 61100 SR4c 47.60 61100 SJ4 3 & 100 A 100 101200 S5d 270.00 101200 SR4c 47.60 4 & 200 A 200 101200 101200 S5d 270.00 101200 101200 SR4c 47.60 5 & 300 A 400 201400 201400 SR5c 107.00 6 & 400, 600 A 600 401600 401600 SR5c 107.00 c Fuse clips are not provided in the Type SR4 and SR5 kits. On new installations Class 9999 Type S fuse clips must also be purchased. Three non-removable pins are supplied and can be installed only in the latest production devices, which have a hole in the lower fuse clips. d Cannot be used in Series B or newer 8538 devices. Disconnect Ampere Rating Device Used on NEMA Class H Fuses Fuse Clip RatingsAmperes NEMA Class R Fuses Fuse Clip RatingsAmperes NEMA Class J Fuses
$ Price
Table 16.371: Class 9999 Auxiliary Contact Kits for Disconnect Switches and Circuit Breakers
Class Type SPDT Type $ Price R45 R26 71.00 131.00 120.00 120.00 113.00 120.00 116.00 120.00 120.00 131.00 131.00 135.00 435.00 DPDT Type R46 R27 TC21 TC20 R7 TC20 R44 TC20 TC20 R42 R9 R40 R36 $ Price Class Type SPDT Type $ Price DPDT Type $ Price
8538, 8738 SB, SC (Series C) 8539, 8739 SB, SC, SD, SE, SF, SG 8538 8738 8538
SBA, SCA, SBG, SCG (Series D) TC11 SBA, SCA, SBG, SCG (Series E) TC10 SBe, SCe, SDe (Series B) R6 SBAS8, SCAS8, SBGS8, SCGS8, TC10 8538 (Series D) 8538, 8738 SD (Series C) R43 SDA, SDAe, SDG, SDGe 8538 TC10 (Series D) 8738 SDA, SDG (Series E) TC10 8538, 8738 SE (Series B & C) R41 8538, 8738 SE, SF (Series A) R8 8538, 8738 SF (Series B & C) R39 8538, 8738 SG R35 e Class 8538 type numbers ending in suffix S8.
207.00 Disconnect Switches BTCF, BTCN, BTDF, BTEF, 243.00 9422 BTEN 239.00 9422 TCF, TCN, TDF, TDN, TEF, TEN 239.00 9422 TF 221.00 Circuit Breaker Op. Mechs. LF, LK, LL, LM, LN, LP LR, LT, , 239.00 9421 LW 221.00 9422 RM, RN, RP RQ, RR, RT , 239.00 239.00 243.00 243.00 243.00 521.00 9422 CFA, CKA, CLA, CSF, CMP
TC21 TC11 R9
NOTE: No external auxiliary contacts are available for the following circuit breakers: GJL circuit breaker must use internal Catalog No. AAC. PowerPactTM D, H and J circuit breaker must use internal Catalog No. AAC.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-124
CP1
DE1
Discount Schedule
General
All tables are based on the operation of the motor and controller in the same ambient temperature, 40oC (104oF) or less. Always be certain the correct thermal units are installed in the starter before operating the motor. Each thermal unit shall be installed such that its catalog number is visible. See page 16-129, Figure 1 for complete thermal unit installation instructions. On melting alloy thermal units the ratchet wheel must engage the pawl assembly.
Selection Procedure
1. Determine motor data: a. b. Full load current rating Service factor Note: If motor full load current (FLC) is not known, a tentative thermal unit selection could be made, based on horsepower and voltage. Refer to page 16-129. 2. Motor and controller in same ambient temperature: a. All starter classes, except Class 8198: 1. 2. b. For 1.15 to 1.25 service factor motors use 100% of motor FLC for thermal unit selection. For 1.0 service factor motors use 90% of motor FLC for thermal unit selection.
Class 8198 only: 1. 2. For 1.0 service factor motors use 100% of motor FLC for thermal unit selection. For 1.15 to 1.25 service factor motors use 110% of motor FLC for thermal unit selection.
3.
Motor and controller in different ambient temperatures: a. Multiply motor FLC by the multiplier in Table A. Use the resultant full load current for thermal unit selection.
4.
Locate proper selection table from index, pages 16-126 and 16-127. a. The proper thermal unit number will be found adjacent, to the right of the range of full load currents in which the motor FLC or resultant full load current falls.
5.
Class of Controller
Full Load Current Multiplier All Classes, Except 8198 Class 8198 1.15 to 1.25 1.0 1.15 to 1.25 1.0 1.0 0.9 1.1 1.0 0.9 0.8 1.0 0.9 1.05 .95 1.15 1.05 1.0 0.9 1.1 1.0
Standard
Standard
Quick Slow
CP1
Discount Schedule
16-125
16
NOTE: For thermal unit selection tables for other devices including obsolete devices, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733).
M, T C, D E F G A (8536 only) SA SB SC SD SE SF SG SH SC
A B, C A, B A A A A A B A B A Bl A, B A A A B A B A A A A A A A B A A
SD 8998 8999 (Model 4 Control Center) SE SF SG SH SCk 8998 (Model 5 and Model 6 MCCs) SDk SEk SFk SGk SHk 8911 DPSG
Table continued on the next page; see page 16-127 for Footnotes.
NOTE: For thermal unit selection tables for other devices including obsolete devices, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733).
16
Thermal Unit Prices . . . . . . . . . . . . . . . . . page 16-125.
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-126
16-127
16
Standard Quick Trip Slow Trip NonCompensated Trip (10) (30) Compensated 8198 G, S 5 j 6 A (8536 only) B, C 00 14h 8536 SA A, B 00 53 j 55 25 (Starter Used in SB, NB A 0 15 78 j 64 33 Multi-Motor Panel) 8538 8904e SC, NC A 1 15 78 j 64 33 8539 8906 SD, ND A 2 58 79 j 57 70 8606 8907 A 3 16 80i 133ij 51 37g 8630c 8920 SE, NE 8640d 8922 B 3 141g 9089 8924 A 4 61 81i 35 29g 8647 8925 SF, NF B 4 143g 8650 8930 8736 8941 A 5 24 52 46 SG 8738 Bl 5 59 83 23 42 8739 SH A, B 6 20 j 48 47 CB, DB, SB, UB A 0 15 78 j 64 33 CC, DC, SC, UC A 1 15 78 j 64 33 AC CD, DD, SD, UD A 2 58 79 j 57 70 Magnetic CE, DE, SE, UE A 3 16 80i 133ij 51 37g Starters 8810 CF, DF, SF, UF A 4 61 81i 35 29g (Large 8811 SE B 3 141g Enclosure) 8812 SF B 4 143g A 5 24 52 46 CG, DG, SG, UG Bl 5 59 83 23 42 CH, DH, SH, UH A 6 20 j 48 47 WC, XC A 1 13 78 33 WD, XD, MD, RD, A 2 56 79 70 WE, XE, ME, RE, A 3 18 80i 37g 8940 WELL-GUARD PF, WF, XF, MF, RF, A 4 54 81i 29g Control A 5 46 XSG, NSG, MG,RG, VGh Bl 5 42 XSH, VH A 6 47 2030 A 136 40 A 147 8911 DPSO A 50 A 148 6090 A 150 SCk A 1 127 121 SDk A 2 128 122 AC 8998 SEk A 3 129 123g Magnetic (Model 5 and PartSF A 4 105 117g Model 6 MCCs) Winding A 5 115 118 SG Bl 5 CT 116 AF B 4(133 A) 30 AG A 5(266 A) 36 AR A 1(25 A) 32 AT A 2(45 A) 60 AU 3(86 A) 50 DA2 A 1(25 A) 140g GA2 A 2(60 A) 139g HA2 A 3(100 A) 138g Separately JA2 A 4(180 A) 137g Mounted 9065 C A 1(25 A) 44 82 j Overload F B 4(133 A) 19 85i Relays G A 5(266 A) 22 MEO A (32 A) 86 1(26 A) 59 83 j 23 42 2(45 A) 69 84 j 27 71 S A 3(86 A) 34 4(133 A) 28 T A 2(45 A) 31 j U 3(86 A) 40 a Series letters listed refer to the marking on the nameplate of the basic open type starter. When the starter is supplied in a controller containing other devices, the controller may have a different series letter marked on the enclosure nameplate. b Small enclosure tables apply for Class 8904 non-combination and non-reversing starters. For combination and reversing Class 8904 starters refer to the large enclosure selections, index above. c For Class 8630 starters divide the delta connected motor full load current by 1.73, and use this quotient to select thermal units. d For Class 8640 and Class 8940 (MD, PD, ME, PE, MF, PF, MG and PG) starters use the full load current of each motor winding as a basis for thermal unit selectionnormally one-half total motor current. e Large enclosure tables apply for Class 8904 combination and reversing starters. For non-combination and non-reversing Class 8904 starters refer to small enclosure selections, page 16-126. f Use for Autotransformer Starters (Fusible and Circuit Breaker). g Order Type E thermal units by number from Square D/Schneider Electric, Furnas Electric Company, Batavia, Illinois or a Furnas distributor at $13.50 each, subject to motor control discounts. h Type A thermal units for full load currents lower than those listed in this table are available. For complete information, consult Square D/Schneider Electric CIC at 1-888-SquareD (1-888-778-2733). i Form Y81 must be specified to use quick trip (Class 10) or slow trip (Class 30) thermal units on Size 3 starters and quick trip (Class 10) thermal units on Size 4 starters. j This device will accept Type SB slow trip (Class 30) thermal units. For selection, see page 16-125. k Refers to type number of starter in MCC, not actual type number of MCC. l Divide the motor FLC by 60 and use this quotient to select the appropriate thermal units.
Calculation Procedure
1. Use the selection table for the specific controller involved. 2. Find the minimum motor full load current listed for the thermal unit in question. 3. Multiply that current by 1.25 (1.15 for Class 8198). The result is the trip current rating. Example 1: Determine the thermal unit selection and trip current rating for thermal units in a Class 8536 Type SCG3 Size 1 magnetic starter used to control a three-phase, 1.15 service factor motor with a full load current of 17.0 Amperes, where the motor and controller are both located in a 40oC (104oF) ambient temperature. 1. From Table 13 the proper selection is B32. 2. The minimum motor full load current is 16. 0 Amperes. 3. Trip current rating is 16.0 x 1.25= 20.0 Amperes. Protection Level is the relationship between trip current rating and full load current. Protection level, in percent, is the trip current rating divided by the motor full load current times 100. In Example 1 the protection level for the B32 thermal unit is: 20.0/17.0 x 100=118%. National Electrical Code, Section 430-32, allows a maximum protection level of 125% for the motor in the above example. Minimum Trip Current (also called ultimate current) may vary from the trip current rating value, since ratings are established under standardized test conditions. Factors which influence variations include: the number of thermal units installed, enclosure size, proximity to heat producing devices, size of conductors installed, ambient (room) temperature, and others. Except for ambient temperature-compensated overload relays, an ambient temperature higher than 40oC would lower the trip current, and a lower temperature would increase it. This variation is not a factor in selecting thermal units for the average application, since most motor ratings are based on an ambient temperature of 40oC, and motor capacity varies with temperature in about the same proportion as the change in trip current. Temperature-compensated relays maintain a nearly constant trip current over a wide range of ambient temperature, and are intended for use where the relay, because of its location, cannot sense changes in the motor ambient temperature.
80 60
40
20 0 -20
0.2
0.4
0.6
0.8
1.0
1.2
1.4
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-128
Instructions:
1. 2. 3. Locate motor horsepower and voltage. Determine approximate full load current from the table below. Use approximate full load current in place of actual nameplate full load current and follow instructions on page 16-125.
Only Use This Table When Motor Full Load Current Is Not Known
Table 16.385:
Motor Full Load Current Motor Horsepower 200 V 1/20 1/12 1/8 1/6 1/4 1/3 1/2 3/4 1 1-1/2 2 3 5 7-1/2 10 15 20 25 30 40 50 60 75 100 125 150 200 0.39 0.55 0.74 0.90 1.22 1.52 2.07 2.88 3.68 5.18 6.67 9.66 15.4 22.6 29.7 43.6 57.4 70.9 84.3 111. 137. 163. 201. 265. 327. 389. 511. 230 V 0.34 0.48 0.64 0.78 1.06 1.32 1.80 2.50 3.20 4.50 5.80 8.40 13.4 19.6 25.8 38.0 49.9 61.7 73.3 96.4 119. 142. 175. 230. 284. 338. 445. Three 460 V 0.17 0.24 0.32 0.39 0.53 0.66 0.90 1.25 1.60 2.25 2.90 4.20 6.68 9.82 12.9 19.0 24.9 30.8 36.7 48.2 59.6 70.8 87.6 115. 142. 169. 222. 575 V 0.14 0.19 0.26 0.31 0.42 0.53 0.72 1.00 1.28 1.80 2.32 3.36 5.35 7.86 10.3 15.2 20.0 24.7 29.3 38.5 47.6 56.6 70.0 92.0 114. 135. 178. 115 V 1.30 1.90 2.60 3.24 4.40 5.47 7.45 10.1 12.6 17.2 21.4 29.1 42.9 58 Single 230 V 0.65 0.95 1.30 1.62 2.20 2.74 3.73 5.07 6.31 8.59 10.7 14.5 21.4 29.2 36.3 49.9
NOTE: These currents should not be used for selection of fuses, circuit breakers or wire sizes. See NEC tables 430-248 through 430-250. For motors rated 208-220 volts, use 230 V column. For motors rated 440 to 550 volts, use 460 and 575 V columns, respectively.
Always be certain the correct thermal units are installed in the starter before operating the motor. Thermal units should always be mounted so that their type designation can be read from the front of the starter (see Figure 1). Melting alloy thermal units should be mounted so that the tooth of the pawl assembly can engage the teeth of the ratchet wheel when the reset button is pushed. Mounting surfaces of starter and thermal units should be clean and care should be taken to insure that thermal unit mounting screws are fastened securely.
Figure 1
16-129
16
Table 1
Motor FLC (A) 1 T.U. 0.330.36 0.370.40 0.410.45 0.460.52 0.530.59 0.600.66 0.670.73 0.740.81 0.820.91 0.921.02 1.031.14 1.151.29 1.201.42 1.431.64 1.651.80 1.812.10 2.112.30 2.312.61 2.622.99 3.003.37 3.383.94 3.954.24 4.254.54 4.555.29 5.305.73 5.746.35 6.367.08 7.097.83 7.848.47 8.489.83 9.8410.5 10.611.4 11.512.8 12.913.9 14.016.1 16.218.0 3 T.U. Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0
Table 2
Motor FLC (A) 1 T.U. 3 T.U. Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0
Table 3
Motor FLC (A) 1 T.U. 3 T.U. Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0
Table 4
Motor FLC (A) 1 T.U. 0.320.33 0.340.38 0.390.41 0.420.50 0.510.61 0.620.68 0.690.74 0.750.83 0.840.93 0.941.05 1.061.21 1.221.34 1.351.50 1.511.70 1.711.93 1.942.12 2.132.38 2.392.61 2.622.99 3.003.53 3.543.80 3.814.21 4.224.49 4.505.10 5.115.66 5.676.03 6.046.79 6.807.84 7.858.96 8.979.82 9.8310.4 10.511.6 11.712.9 13.013.9 14.015.7 15.818.0 3 T.U. Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0
0.290.32 0.330.36 0.370.39 0.400.47 0.480.56 0.570.63 0.640.69 0.700.77 0.780.86 0.870.96 0.971.11 1.121.23 1.241.37 1.381.55 1.561.75 1.761.92 1.932.16 2.172.50 2.512.81 2.823.16 3.173.40 3.413.76 3.774.00 4.014.68 4.695.18 5.195.51 5.526.19 6.207.12 7.138.15 8.168.60 8.619.21 9.2210.1 10.211.2 11.312.0 Following Selections for Size M-1 & M-1P Only. 11.312.1 12.213.6 16.217.6 13.715.3 17.720.6 15.417.3 20.723.1 17.419.1 23.226.0 19.221.7 21.824.2 24.326.0 Following Selections for Size M-1P Only 23.227.1 27.229.2 29.333.0 33.136.0
B B B B B B B B
B B B B
0.350.38 0.300.32 0.390.43 0.330.37 0.440.48 0.380.39 0.490.56 0.400.48 0.570.63 0.490.57 0.640.71 0.580.64 0.720.78 0.650.70 0.790.88 0.710.78 0.890.99 0.790.87 1.001.15 0.880.98 1.161.23 0.991.13 1.241.43 1.141.25 1.441.51 1.261.40 1.521.75 1.411.58 1.761.93 1.591.79 1.942.25 1.801.91 2.262.47 1.922.20 2.482.81 2.212.55 2.823.20 2.562.87 3.213.63 2.883.24 3.644.19 3.253.48 4.204.53 3.493.85 4.544.89 3.864.10 4.905.68 4.114.79 5.696.27 4.805.31 6.286.85 5.325.65 6.867.73 5.666.35 7.748.50 6.367.31 8.519.29 7.328.34 9.3010.4 8.358.84 10.511.3 8.859.47 11.412.3 9.4810.4 12.413.9 10.511.5 14.015.0 11.612.0 15.118.0 Following Selections for Size M-1 & M-1P Only. 11.612.4 15.117.4 12.514.0 17.519.2 14.115.8 19.322.0 15.917.8 22.124.6 17.919.7 24.726.0 19.822.4 22.525.1 25.126.0 Following Selections for Size M-1P Only. 24.729.1 29.231.7 31.836.0
B B B B B B B B
0.290.31 0.280.29 0.320.36 0.300.33 0.370.39 0.340.36 0.400.47 0.370.44 0.480.56 0.450.52 0.570.63 0.530.59 0.640.69 0.600.64 0.700.77 0.650.71 0.780.86 0.720.80 0.870.97 0.810.90 0.981.12 0.911.03 1.131.24 1.041.14 1.251.39 1.151.27 1.401.57 1.281.44 1.581.78 1.451.63 1.791.96 1.641.79 1.972.20 1.802.01 2.212.41 2.022.19 2.422.75 2.202.52 2.763.25 2.532.95 3.263.50 2.963.17 3.513.87 3.183.50 3.884.13 3.513.73 4.144.69 3.744.22 4.705.20 4.234.68 5.215.53 4.694.98 5.546.23 4.995.59 6.247.18 5.606.43 7.198.20 6.447.41 8.218.98 7.428.02 8.999.63 8.038.59 9.6410.6 8.609.52 10.711.8 9.5310.5 11.912.7 10.611.2 12.814.3 11.312.0 14.416.1 16.218.0 Following Selections for Size M-1 & M-1P Only. 11.312.7 12.814.3 16.218.3 14.416.1 18.420.2 16.217.8 20.323.0 17.920.1 23.126.0 20.222.6 22.725.5 25.626.0 Following Selections for Size M-1P Only 25.929.0 29.130.8 30.932.7 32.836.0
B B B B B B B B
B B B B
0.290.30 0.310.35 0.360.37 0.380.45 0.460.54 0.550.61 0.620.66 0.670.74 0.750.83 0.840.93 0.941.07 1.081.19 1.201.33 1.341.51 1.521.70 1.711.87 1.882.10 2.112.29 2.302.63 2.643.09 3.103.32 3.333.67 3.683.91 3.924.43 4.444.91 4.925.23 5.245.88 5.896.77 6.787.90 7.918.44 8.459.05 9.069.99 10.011.0 11.111.9 12.012.0 Following Selections for Size M-1 & M-1P Only. 12.013.4 13.515.1 17.820.1 15.217.0 20.222.2 17.118.9 22.325.3 19.021.4 25.426.0 21.524.0 24.126.0 Following Selections for Size M-1P Only. 25.428.4 28.533.1 33.236.0
B B B B B B B
Table 5
Current Transformer Ratio 25/5 10.611.7 11.813.2 13.314.8 14.917.2 17.319.6 19.722.3 50/5 21.123.6 23.726.5 26.629.6 29.734.5 34.639.2 39.344.6 75/5 31.735.4 35.539.8 39.944.5 44.651.8 51.958.9 59.067.0 100/5 42.347.2 47.353.1 53.259.4 59.569.2 69.378.6 78.789.3 150/5 200/5 250/5 106.117. 118.132. 133.148. 149.172. 173.196. 197.223. 300/5 127.141. 142.159. 160.177. 178.207. 208.235. 236.267. 400/5 169.188. 189.212. 213.237. 238.276. 277.314. 315.357. 500/5 211.236. 237.265. 266.296. 297.345. 346.360. Thermal Unit Number B B B B B B 3.00 3.30 3.70 4.15 4.85 5.50
Motor FLC 63.470.9 84.594.6 71.079.7 94.7105. 79.889.1 106.118. 89.2103. 119.138. 104.117. 139.156. 118.133. 157.178.
Table 6
Current Transformer Ratio 25/5 10.611.9 12.013.4 13.515.0 15.116.6 16.718.7 18.820.7 20.822.8 50/5 21.223.9 24.026.9 27.030.0 30.133.4 33.537.5 37.641.4 41.545.7 75/5 31.835.9 36.040.3 40.445.1 45.250.1 50.256.3 56.462.2 62.368.5 100/5 42.447.9 48.053.8 53.960.1 60.266.9 67.075.1 75.282.9 83.091.4 150/5 200/5 250/5 106.119. 120.134. 135.150. 151.166. 167.187. 188.207. 208.228. 300/5 127.143. 144.161. 162.180. 181.200. 201.225. 226.248. 249.274. 400/5 170.191. 192.215. 216.240. 241.267. 268.300. 301.331. 332.365. 500/5 212.239. 240.269. 270.300. 301.334. 335.360. Thermal Unit Number AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4
Motor FLC 63.672.0 84.896.0 72.180.8 96.1107. 80.990.2 108.119. 90.399.9 120.133. 100.112. 134.149. 113.124. 150.165. 125.136. 166.182.
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-130
Table 8
Motor FLC (A) 2.T.U.1 0.370.39 0.400.42 0.430.46 0.470.50 0.510.54 0.550.59 0.600.65 0.660.71 0.720.78 0.790.86 0.870.94 0.951.04 1.051.14 1.151.25 1.261.42 1.431.62 1.631.75 1.761.91 1.922.07 2.082.25 2.262.47 2.482.73 2.742.99 3.003.31 3.323.71 3.724.15 4.164.65 4.665.11 5.125.68 5.696.24 6.257.15 7.167.84 7.858.56 8.579.40 9.4110.2 10.310.7 10.812.2 12.314.1 14.215.9 16.018.0 16.018.1 18.220.8 20.923.6 23.726.0 2 T.U.2 3 T.U. Thermal Unit Number AR .45 AR .49 AR .54 AR .59 AR .65 AR .71 AR .78 AR .86 AR .95 AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR AR AR AR AR AR AR AR AR 13.6 15.4 17.6 20.5 23.0 27.0 30.0 35.0 40.0
Table 9
Motor FLC (A) 15.316.7 16.819.8 19.922.8 22.925.8 25.930.4 30.531.9 32.034.2 34.338.8 38.944.2 44.350.2 50.357.1 57.263.2 63.368.6 68.778.6 78.786.9 87.0100.0 Thermal Unit Number C 20.0 C 22.0 C 26.0 C 30.0 C 34.0 C 40.0 C 42.0 C 45.0 C 51.0 C 58.0 C 66.0 C 75.0 C 83.0 C 90.0 C 103.0 C 114.0
0.370.39 0.300.31 0.400.42 0.320.34 0.430.46 0.350.37 0.470.50 0.380.41 0.510.54 0.420.45 0.550.59 0.460.49 0.600.65 0.500.54 0.660.71 0.550.56 0.720.78 0.570.62 0.790.86 0.630.68 0.870.94 0.690.75 0.951.04 0.760.82 1.051.14 0.830.91 1.151.25 0.921.00 1.261.42 1.011.18 1.431.62 1.191.30 1.631.75 1.311.41 1.761.91 1.421.53 1.922.07 1.541.69 2.082.25 1.701.79 2.262.47 1.802.02 2.482.73 2.032.19 2.742.99 2.202.43 3.003.31 2.442.81 3.323.71 2.823.12 3.724.15 3.133.47 4.164.65 3.483.89 4.665.11 3.904.30 5.125.68 4.314.69 5.696.24 4.705.19 6.257.15 5.205.93 7.167.84 5.946.45 7.858.56 6.467.08 8.579.40 7.097.71 9.4110.2 7.728.39 10.310.7 8.408.64 10.812.2 8.659.74 9.7511.0 11.112.0 Following Selections for Size 1 Only 10.812.2 12.314.1 14.215.9 11.112.4 16.018.1 12.513.9 18.220.8 14.015.9 20.923.6 16.017.7 23.726.0 17.820.3 20.422.8 22.926.0
Table 10
Motor FLC (A) 43.647.3 47.451.3 51.454.6 54.759.7 59.865.1 65.270.1 70.275.1 75.282.2 82.389.2 89.396.5 96.6104. 105.113. 114.123. 124.132. 133.150. Thermal Unit Number CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0
Table 11
Motor FLC (A) 2 T.U. 33.036.1 36.240.2 40.344.5 45.651.3 51.458.5 58.662.6 62.771.3 71.477.1 77.286.9 87.093.3 93.4102. 103.107. 108.112. 113.121. 122.123. 124.133. 3 T.U. 30.533.4 33.537.1 37.242.0 42.147.0 47.153.5 53.657.5 57.664.4 64.569.4 69.577.4 77.583.6 83.792.9 93.0100. 101.104. 105.115. 116.119. 120.123. 124.133. Thermal Unit Number AU 44.0 AU 50.0 AU 56.0 AU 64.0 AU 72.0 AU 81.0 AU 88.0 AU 99.0 AU 110.0 AU 123.0 AU 135.0 AU 152.0 AU 169.0 AU 183.0 AU 198.0 AU 217.0 AU 235.0
Table 12
Motor FLC (A) 92.100. 101.109. 110.119. 120.131. 132.139. 140.156. 157.166. 167.180. 181.189. 190.209. 210.225. 226.238. 239.263. 264.300. Thermal Unit Number DD 112.0 DD 121.0 DD 128.0 DD 140.0 DD 150.0 DD 160.0 DD 185.0 DD 213.0 DD 220.0 DD 230.0 DD 250.0 DD 265.0 DD 280.0 DD 300.0
16-131
16
Table 13
Motor FLC (A) 1.T.U. 2 T.U. 3 T.U. Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B B B B B B B B B 19.5 22.0 25.0 28.0 32.0 36.0 40.0 45.0 50.0
Table 15
Motor FLC (A) 1.T.U. 2 T.U. 3 T.U. Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B B B B B B B B B 17.5 19.5 22.0 25.0 28.0 32.0 36.0 40.0 45.0
Table 17
Motor FLC (A) 1.T.U. 0.420.46 0.470.50 0.510.55 0.560.62 0.630.67 0.680.73 0.740.81 0.820.89 0.900.98 0.991.12 1.131.20 1.211.34 1.351.41 1.421.51 1.521.62 1.631.73 1.741.86 1.872.02 2.032.25 2.262.46 2.472.77 2.782.99 3.003.26 3.273.59 3.603.99 4.004.42 4.434.61 4.625.23 5.245.39 5.405.88 5.896.56 6.577.18 7.197.80 7.819.00 2 T.U. 0.390.43 0.440.47 0.480.52 0.530.58 0.590.64 0.650.68 0.690.77 0.780.84 0.850.93 0.941.05 1.061.13 1.141.25 1.261.33 1.341.42 1.431.52 1.531.63 1.641.75 1.761.90 1.912.13 2.142.33 2.342.73 2.742.86 2.873.14 3.153.47 3.483.83 3.844.16 4.174.43 4.445.00 5.015.16 5.175.56 5.576.22 6.236.89 6.907.00 3 T.U. 0.380.40 0.410.44 0.450.49 0.500.55 0.560.60 0.610.65 0.660.72 0.730.79 0.800.88 0.890.98 0.991.07 1.081.17 1.181.25 1.261.33 1.341.44 1.451.53 1.541.65 1.661.79 1.801.99 2.002.18 2.192.45 2.462.65 2.662.90 2.913.19 3.203.56 3.573.83 3.844.08 4.094.64 4.655.00 5.015.36 5.375.87 5.886.43 6.446.79 6.807.00 Thermal Unit Number A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .95 A 1.02 A 1.16 A 1.25 A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 A 11.0
0.290.31 0.290.31 0.280.30 0.320.34 0.320.34 0.310.34 0.350.38 0.350.38 0.350.37 0.390.45 0.390.45 0.380.44 0.460.54 0.460.54 0.450.53 0.550.61 0.550.61 0.540.59 0.620.66 0.620.66 0.600.64 0.670.73 0.670.73 0.650.72 0.740.81 0.740.81 0.730.80 0.820.94 0.820.94 0.810.90 0.951.05 0.951.05 0.911.03 1.061.22 1.061.22 1.041.14 1.231.34 1.231.34 1.151.27 1.351.51 1.351.51 1.281.43 1.521.71 1.521.71 1.441.62 1.721.93 1.721.93 1.631.77 1.942.14 1.942.14 1.781.97 2.152.40 2.152.40 1.982.32 2.412.72 2.412.72 2.332.51 2.733.15 2.733.15 2.522.99 3.163.55 3.163.55 3.003.42 3.564.00 3.564.00 3.433.75 4.014.40 4.014.40 3.763.98 4.414.88 4.414.88 3.994.48 4.895.19 4.895.19 4.494.93 5.205.73 5.205.73 4.945.21 5.746.39 5.746.39 5.225.84 6.407.13 6.407.13 5.856.67 7.147.90 7.147.90 6.687.54 7.918.55 7.918.55 7.558.14 8.569.53 8.569.53 8.158.72 9.5410.6 9.5410.6 8.739.66 10.711.8 10.711.8 9.6710.5 11.913.2 11.912.0 10.611.3 13.314.9 11.412.0 15.016.6 16.718.0 Following Selections for Size 1 Only 11.913.2 13.314.9 11.412.7 15.016.6 12.814.1 16.718.9 16.718.9 14.215.9 19.021.2 19.021.2 16.017.5 21.323.0 21.323.0 17.619.7 23.125.5 23.125.5 19.821.9 25.626.0 25.626.0 22.024.4 24.526.0
0.310.33 0.310.33 0.290.31 0.340.36 0.340.36 0.320.36 0.370.40 0.370.40 0.370.38 0.410.48 0.410.48 0.390.46 0.490.57 0.490.57 0.470.55 0.580.64 0.580.64 0.560.61 0.650.70 0.650.70 0.620.66 0.710.77 0.710.77 0.670.75 0.780.85 0.780.85 0.760.83 0.860.99 0.860.99 0.840.93 1.001.10 1.001.10 0.941.06 1.111.28 1.111.28 1.071.18 1.291.41 1.291.41 1.191.31 1.421.58 1.421.58 1.321.47 1.591.80 1.591.80 1.481.67 1.812.03 1.812.03 1.681.83 2.042.25 2.042.25 1.842.04 2.262.51 2.262.51 2.052.38 2.522.83 2.522.83 2.392.60 2.843.29 2.843.29 2.613.13 3.303.75 3.303.75 3.143.59 3.764.22 3.764.22 3.603.94 4.234.65 4.234.65 3.954.19 4.665.16 4.665.16 4.204.72 5.175.53 5.175.53 4.735.21 5.546.09 5.546.09 5.225.51 6.106.80 6.106.80 5.526.17 6.817.60 6.817.60 6.187.07 7.618.35 7.618.35 7.088.05 8.369.04 8.369.04 8.068.69 9.059.99 9.059.99 8.709.32 10.011.1 10.011.1 9.3310.2 11.212.3 11.212.0 10.311.3 12.413.7 11.412.0 13.815.4 15.518.0 Following Selections for Size 1 Only 11.212.3 12.413.7 11.412.1 13.815.4 12.213.7 15.517.2 15.517.2 13.815.2 17.319.4 17.319.4 15.317.2 19.521.7 19.521.7 17.318.9 21.823.9 21.823.9 19.021.4 24.026.0 24.026.0 21.523.7 23.826.0
Table 18
Motor FLC (A) 1.T.U. 15.516.4 16.517.6 17.719.1 19.220.4 20.522.1 22.223.4 23.525.6 25.727.3 27.429.4 29.531.5 31.633.7 33.836.5 36.639.1 39.241.7 41.844.8 44.948.0 48.150.7 50.854.9 55.059.9 60.063.3 63.467.2 67.372.4 72.574.9 75.077.4 77.580.7 80.883.1 83.286.0 2 T.U. 14.415.3 15.416.4 16.518.4 18.519.6 19.721.0 21.122.7 22.824.2 24.325.9 26.027.8 27.929.8 29.931.7 31.834.2 34.336.9 37.039.8 39.942.3 42.445.3 45.447.9 48.051.9 52.056.5 56.660.7 60.864.8 64.967.1 67.270.1 70.272.9 73.074.9 75.077.9 78.080.9 81.082.9 83.086.0 3 T.U. 13.614.5 14.615.5 15.617.4 17.518.5 18.619.9 20.021.5 21.622.9 23.024.5 24.626.3 26.428.2 28.330.0 30.132.3 32.434.9 35.037.6 37.740.0 40.142.8 42.945.3 45.449.1 49.253.4 53.557.4 57.561.3 61.463.5 63.666.3 66.469.0 69.170.9 71.073.7 73.876.5 76.678.4 78.586.0 Thermal Unit Number CC 20.9 CC 22.8 CC 24.6 CC 26.3 CC 28.8 CC 31.0 CC 33.3 CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0
Table 14
Motor FLC (A) 1.T.U. 0.430.47 0.480.51 0.520.56 0.570.64 0.650.69 0.700.76 0.770.84 0.850.91 0.921.01 1.021.15 1.161.23 1.241.37 1.381.45 1.461.56 1.571.67 1.681.77 1.781.92 1.932.09 2.102.31 2.322.56 2.572.92 2.933.16 3.173.48 3.493.83 3.844.24 4.254.62 4.634.92 4.935.61 5.625.85 5.866.36 6.376.99 7.007.67 7.688.15 8.169.00 2 T.U. 0.410.45 0.460.50 0.510.55 0.560.62 0.630.67 0.680.72 0.730.81 0.820.88 0.890.97 0.981.08 1.091.18 1.191.32 1.331.40 1.411.48 1.491.60 1.611.72 1.731.84 1.852.00 2.012.22 2.232.45 2.462.82 2.833.08 3.093.39 3.403.75 3.764.16 4.174.51 4.524.83 4.845.49 5.505.67 5.686.16 6.176.75 6.767.00 3 T.U. 0.400.41 0.420.46 0.470.51 0.520.57 0.580.62 0.630.67 0.680.75 0.760.80 0.810.89 0.901.02 1.031.09 1.101.21 1.221.29 1.301.37 1.381.48 1.491.58 1.591.72 1.731.85 1.862.05 2.062.29 2.302.62 2.632.84 2.853.10 3.113.46 3.473.85 3.864.16 4.174.46 4.475.08 5.095.35 5.365.82 5.836.34 6.356.95 6.967.00 Thermal Unit Number A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .95 A 1.02 A 1.16 A 1.25 A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 A 11.0
Table 16
Motor FLC (A) 1.T.U. 16.217.5 17.618.8 18.920.5 20.622.2 22.323.7 23.825.4 25.527.3 27.429.3 29.431.5 31.633.9 34.036.2 36.339.3 39.442.3 42.445.3 45.448.3 48.452.0 52.154.9 55.059.7 59.865.4 65.569.6 69.774.8 74.979.7 79.883.1 83.286.0 2 T.U. 15.116.2 16.317.3 17.419.5 19.620.7 20.822.3 22.424.0 24.125.7 25.827.5 27.629.6 29.731.7 31.833.9 34.036.6 36.739.3 39.442.3 42.444.9 45.048.3 48.450.9 51.055.5 55.659.9 60.064.2 64.368.7 68.871.4 71.574.8 74.978.0 78.180.7 80.886.0 3 T.U. 14.315.4 15.516.4 16.518.5 18.619.6 19.721.1 21.222.7 22.824.4 24.526.1 26.228.1 28.230.0 30.132.1 32.234.7 34.837.3 37.440.1 40.242.6 42.745.8 45.948.3 48.452.6 52.756.8 56.960.9 61.065.1 65.267.7 67.870.9 71.073.9 74.076.5 76.680.2 80.383.1 83.286.0 Thermal Unit Number CC 20.9 CC 22.8 CC 24.6 CC 26.3 CC 28.8 CC 31.0 CC 33.3 CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-132
Table 19
Motor FLC (A) 43.647.3 47.451.3 51.454.6 54.759.7 59.865.1 65.270.1 70.275.1 75.282.2 82.389.2 89.396.5 96.6104. 105.113. 114.123. 124.133. Thermal Unit Number CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0
Table 23
Motor FLC (A) 2 or 3 T.U. Large Enclosure 0.310.32 0.330.36 0.370.39 0.400.43 0.440.47 0.480.52 0.530.58 0.590.60 0.610.62 0.630.69 0.700.76 0.770.84 0.850.93 0.941.03 1.041.23 1.241.35 1.361.47 1.481.61 1.621.76 1.771.93 1.942.12 2.132.35 2.362.61 2.622.79 2.803.14 3.153.48 3.493.89 3.904.30 4.314.73 4.745.20 5.215.95 5.966.49 6.507.08 7.097.77 7.788.48 8.499.15 9.1610.3 10.411.9 12.013.4 13.515.4 15.517.5 17.619.8 19.922.5 22.626.0 Small Enclosure 0.290.30 0.310.33 0.340.37 0.380.41 0.420.45 0.460.50 0.510.55 0.560.57 0.580.60 0.610.66 0.670.73 0.740.81 0.820.90 0.910.99 1.001.18 1.191.30 1.311.42 1.431.49 1.501.69 1.701.85 1.862.03 2.042.25 2.262.50 2.512.68 2.693.01 3.023.35 3.363.74 3.754.14 4.154.57 4.585.03 5.045.76 5.776.29 6.306.87 6.887.54 7.558.25 8.268.60 8.619.63 9.6411.1 11.212.5 12.614.3 14.416.1 16.218.2 18.320.6 20.723.4 23.526.0 Thermal Unit Number AR .45 AR .49 AR .54 AR .59 AR .65 AR .71 AR .78 AR .86 AR .95 AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0
Table 25
Motor FLC (A) 0.280.30 0.310.33 0.340.36 0.370.39 0.400.42 0.430.46 0.470.50 0.510.52 0.530.56 0.570.60 0.610.66 0.670.73 0.740.81 0.820.90 0.911.05 1.061.15 1.161.25 1.261.35 1.361.47 1.481.58 1.591.74 1.751.94 1.952.20 2.212.47 2.482.76 2.773.07 3.083.45 3.463.81 3.824.20 4.214.65 4.665.29 5.305.84 5.856.27 6.287.00 Thermal Unit Number AR .45 AR .49 AR .54 AR .59 AR .65 AR .71 AR .78 AR .86 AR .95 AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2
Table 20
Motor FLC (A) 133.148. 149.174. 175.195. 196.219. 220.239. 240.271. 272.308. 309.348. 349.397. 398.429. 430.495. 496.520. Thermal Unit Number B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85
Table 21
Motor FLC (A) 128.140. 141.163. 164.179. 180.201. 202.227. 228.251. 252.278. 279.308. 309.346. 347.380. 381.426. 427.454. 455.489. 490.520. Thermal Unit Load B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25
Table 26
Size 7 Type J 120/5 Motor FLC 166.187. 188.211. 212.232. 233.267. 268.301. 302.336. 337.383. 384.425. 426.466. 467.522. 523.587. 588.656. 657.764. 277.312. 313.352. 353.388. 389.445. 446.503. 504.561. 562.640. 641.708. 709.777. 778.870. 871.978. 979.1093. 1094.1215. B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 Size 8 Type K 2000/5 Thermal Unit Number Current Transformer Ratio
Table 24
Motor FLC (A) 88.295.1 95.2101. 102.111. 112.119. 120.131. 132.149. 150.170. 171.180. 181.197. 198.204. 205.213. 214.237. 238.243. 244.266. Thermal Unit Number DD 112.0 DD 121.0 DD 128.0 DD 140.0 DD 150.0 DD 160.0 DD 185.0 DD 220.0 DD 240.0 DD 250.0 DD 265.0 DD 280.0 DD 300.0 DD 320.0
Table 22
Motor FLC (A) 92.0100. 101.109. 110.119. 120.131. 132.139. 140.156. 157.166. 167.180. 181.189. 190.209. 210.225. 226.238. 239.266. Thermal Unit Number DD 112.0 DD 121.0 DD 128.0 DD 140.0 DD 150.0 DD 160.0 DD 185.0 DD 213.0 DD 220.0 DD 230.0 DD 250.0 DD 265.0 DD 280.0
Table 27
Motor FLC (A) 2 or 3 T.U. Large Enclosure 4.324.93 4.945.40 5.415.95 5.966.13 6.146.81 6.827.84 7.858.97 8.9810.1 10.211.6 11.713.2 13.315.0 15.117.1 17.219.6 19.721.9 22.023.8 23.925.6 25.727.9 28.030.5 30.633.0 33.135.7 35.839.5 39.641.5 41.645.0 Small Enclosure 4.144.71 4.725.18 5.195.74 5.755.98 5.996.47 6.487.42 7.438.46 8.479.56 9.5710.9 11.012.3 12.414.0 14.115.9 16.018.1 18.220.3 20.422.0 22.123.6 23.725.5 25.627.8 27.930.0 30.132.4 32.535.7 35.838.3 38.440.9 41.045.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0 AR 94.0
16-133
16
Table 28
Motor FLC (A) 2 or 3 T.U. Large Small Enclosure Enclosure 45.348.2 40.342.8 CC 64.3 48.352.4 42.946.2 CC 68.5 52.556.4 46.349.8 CC 74.6 56.561.2 49.954.9 CC 81.5 61.366.1 55.057.9 CC 87.7 66.271.4 58.062.5 CC 94.0 71.577.0 62.667.3 CC 103.0 77.180.7 67.473.4 CC 112.0 80.887.7 73.578.9 CC 121.0 87.894.9 79.084.9 CC 132.0 95.0102. 85.091.0 CC 143.0 103.110. 91.197.2 CC 156.0 111.117. 97.3104. CC 167.0 118.133. 105.121. CC 180.0 122.133. CC 196.0 Thermal Unit Number
Table 31
Motor FLC (A) 0.310.35 0.360.39 0.400.44 0.450.50 0.510.61 0.620.68 0.690.73 0.740.82 0.830.92 0.931.03 1.041.19 1.201.34 1.351.50 1.511.74 1.751.97 1.982.14 2.152.47 2.482.91 2.923.31 3.323.75 3.764.05 4.064.94 4.955.52 5.536.11 6.126.52 6.537.31 7.328.43 8.449.83 9.8410.7 10.811.6 11.712.9 13.014.3 14.415.7 15.817.8 17.920.3 20.423.3 23.426.6 26.730.3 30.435.3 35.441.5 41.645 Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0
Table 33
Thermal Motor FLC (A) Unit Number 0.280.30 AR .45 0.310.33 AR .49 0.340.36 AR .54 0.370.39 AR .59 0.400.42 AR .65 0.430.46 AR .71 0.470.50 AR .78 0.510.52 AR .86 0.530.56 AR .95 0.570.60 AR 1.05 0.610.66 AR 1.15 0.670.73 AR 1.26 0.740.81 AR 1.39 0.820.90 AR 1.53 0.911.05 AR 1.68 1.061.15 AR 1.85 1.161.25 AR 2.04 1.261.35 AR 2.24 1.361.47 AR 2.46 1.481.58 AR 2.71 1.591.74 AR 2.98 1.751.94 AR 3.28 1.952.20 AR 3.62 2.212.47 AR 3.98 2.482.76 AR 4.37 2.773.07 AR 4.80 3.083.45 AR 5.3 3.463.81 AR 5.8 3.824.20 AR 6.4 4.214.65 AR 7.0 4.665.29 AR 7.7 5.305.84 AR 8.5 5.856.27 AR 9.3 6.286.97 AR 10.2 6.987.59 AR 11.2 7.607.89 AR 12.4 7.908.95 AR 13.6 8.9610.3 AR 15.4 10.411.7 AR 17.6 11.812.0 AR 20.5 Following Selections for Size 1 Only 11.813.3 AR 20.5 13.415.2 AR 23.0 15.317.2 AR 27.0 17.319.7 AR 30.0 19.822.4 AR 35.0 22.526.0 AR 40.0
Table 36
Motor FLC (A) 90.697.4 97.5111. 112.129. 130.149. 150.163. 164.189. 190.213. 214.240. 241.266. Thermal Unit Number AF 110.0 AF 123.0 AF 135.0 AF 150.0 AF 159.0 AF 168.0 AF 188.0 AF 205.0 AF 220.0
Table 41
Motor FLC (A) 0.810.92 0.931.07 1.081.14 1.151.26 1.271.49 1.501.73 1.741.89 1.902.16 2.172.37 2.382.66 2.672.99 3.003.40 3.413.94 3.954.15 4.164.49 4.505.15 5.165.77 5.786.61 6.627.14 7.157.97 7.988.15 8.169.32 9.339.97 9.9810.7 10.812.0 12.113.9 14.015.7 15.818.4 18.521.6 21.724.0 24.128.6 28.730.7 30.833.5 33.636.0 Thermal Unit Number B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0
Table 37
Motor FLC (A) 27.130.0 30.133.2 33.335.7 35.839.4 39.543.4 43.546.9 47.051.5 51.657.0 57.162.8 62.969.1 69.275.0 75.183.3 Thermal Unit Number E 67 E 69 E 70 E 71 E 72 E 73 E 74 E 76 E 77 E 78 E 79 E 80
Table 29
Motor FLC (A) 50.055.9 56.060.9 61.065.9 66.069.9 70.075.9 76.081.9 82.086.9 87.092.9 93.097.9 98.0107.9 108.0113.9 114.0125.9 Thermal Unit Number E 88 E 89 E 91 E 92 E 93 E 94 E 96 E 97 E 98 E 99 E 101 E 102
Table 38
Motor FLC (A) 85.095.9 96.0108. 109.127. 128.136. 137.147. 148.162. 163.185. 186.202. 203.219. 220.233. 234.266. Thermal Unit Number AF 123.0 AF 135.0 AF 150.0 AF 159.0 AF 168.0 AF 188.0 AF 205.0 AF 220.0 AF 240.0 AF 260.0 AF 308.0
Table 42
Motor FLC (A) 0.280.30 0.310.33 0.340.36 0.370.39 0.400.42 0.430.46 0.470.50 0.510.52 0.530.56 0.570.60 0.610.66 0.670.73 0.740.81 0.820.90 0.911.05 1.061.15 1.161.25 1.261.35 1.361.47 1.481.58 1.591.74 1.751.94 1.952.20 2.212.47 2.482.76 2.773.07 3.083.45 3.463.81 3.824.20 4.214.65 4.665.29 5.305.84 5.856.27 6.286.97 6.987.59 7.607.89 7.908.95 8.9610.3 10.411.7 11.813.3 13.415.2 15.317.2 17.319.7 19.822.4 22.526.0 Thermal Unit Number AR .45 AR .49 AR .54 AR .59 AR .65 AR .71 AR .78 AR .86 AR .95 AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0
Table 30
Motor FLC (A) Large Enclosure 39.042.9 43.048.0 48.154.7 54.862.2 62.371.3 71.476.0 76.185.5 85.692.4 92.5103. 104.111. 112.123. 124.133. Small Enclosure 37.040.8 40.945.6 45.751.8 51.958.8 58.967.4 67.570.4 70.579.4 79.586.3 86.496.7 96.8105. 106.117. 118.133. Thermal Unit Number AU 44.0 AU 50.0 AU 56.0 AU 64.0 AU 72.0 AU 81.0 AU 88.0 AU 99.0 AU 110.0 AU 123.0 AU 135.0 AU 152.0
Table 32
Motor FLC (A) 0.330.35 0.360.39 0.400.42 0.430.46 0.470.51 0.520.56 0.570.62 0.630.68 0.690.75 0.760.83 0.840.91 0.921.00 1.011.10 1.111.21 1.221.33 1.341.47 1.481.62 1.631.77 1.781.96 1.972.16 2.172.37 2.382.62 2.632.88 2.893.17 3.183.48 3.493.83 3.844.20 4.214.62 4.635.08 5.095.57 5.586.13 6.146.83 6.847.41 7.428.05 8.068.98 8.999.93 9.9410.9 11.012.4 12.514.3 14.415.8 15.917.9 18.020.0 20.122.4 22.525.0 Thermal Unit Number AR .45 AR .49 AR .54 AR .59 AR .65 AR .71 AR .78 AR .86 AR .95 AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0
Table 39
Motor FLC (A) Thermal Unit Number AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8
Table 34
Motor FLC (A) 15.116.2 16.317.5 17.619.1 19.220.7 20.822.2 22.324.0 24.125.7 25.827.8 27.930.1 30.232.5 32.635.1 35.238.0 38.141.1 41.244.0 44.147.2 47.351.1 51.255.8 55.959.5 59.664.5 64.669.5 69.675.0 75.178.1 78.282.3 82.486.0 Thermal Unit Number CC 20.9 CC 22.8 CC 24.6 CC 26.3 CC 28.8 CC 31.0 CC 33.3 CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0
148.173. 174.189. 190.205. 206.222. 223.243. 244.261. 262.289. 290.324. 325.367. 368.389. 390.404. 405.451. 452.495. 496.520.
Table 40
Motor FLC (A) 15.316.7 16.819.8 19.922.8 22.925.8 25.930.4 30.531.9 32.034.2 34.338.8 38.944.2 44.350.2 50.357.1 57.263.2 63.368.6 68.778.6 78.786.0 Thermal Unit Number C 20.0 C 22.0 C 26.0 C 30.0 C 34.0 C 40.0 C 42.0 C 45.0 C 51.0 C 58.0 C 66.0 C 75.0 C 83.0 C 90.0 C 103.0
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
Table 35
Motor FLC (A) 2 T.U. 36.339.9 40.044.1 44.250.0 50.156.4 56.564.4 64.568.4 68.577.7 77.884.2 84.394.8 94.9101. 102.115. 116.122. 123.133. 3 T.U. 34.737.1 37.241.5 41.647.1 47.253.4 53.560.7 60.864.9 65.073.4 73.579.5 79.689.0 89.196.9 97.0108. 109.115. 116.120. 121.133. Thermal Unit Number AU 44.0 AU 50.0 AU 56.0 AU 64.0 AU 72.0 AU 81.0 AU 88.0 AU 99.0 AU 110.0 AU 123.0 AU 135.0 AU 152.0 AU 169.0 AU 183.0
16-134
Table 43
Motor FLC (A) 0.410.44 0.450.49 0.500.53 0.540.58 0.590.65 0.660.71 0.720.78 0.790.85 0.860.96 0.971.04 1.051.16 1.171.29 1.301.37 1.381.47 1.481.56 1.571.65 1.661.79 1.801.95 1.962.15 2.162.38 2.392.75 2.762.84 2.853.06 3.073.45 3.463.70 3.714.07 4.084.32 4.334.90 4.915.35 5.365.85 5.866.41 6.426.79 6.807.57 7.588.15 8.168.98 8.999.67 9.689.95 9.9610.8 10.912.1 12.213.1 13.213.9 14.015.0 15.116.0 Thermal Unit Number A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .95 A 1.02 A 1.16 A 1.25 A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9 A 19.8 A 21.3 A 25.2
Table 45
Size 7 Type J Size 8 Type K Thermal Unit Number
Table 49
Motor FLC (A) 82.588.2 88.395.9 96.0102. 103.109. 110.121. 122.139. 140.154. 155.163. 164.175. 176.184. 185.195. 196.215. 216.224. 225.243. 244.266. Thermal Unit Number DD 112.0 DD 121.0 DD 128.0 DD 140.0 DD 150.0 DD 160.0 DD 185.0 DD 220.0 DD 240.0 DD 250.0 DD 265.0 DD 280.0 DD 300.0 DD 320.0 DD 340.0
Table 53
Motor FLC (A) 1 T. U. 0.310.33 0.340.36 0.370.40 0.410.48 0.490.57 0.580.64 0.650.70 0.710.77 0.780.85 0.860.99 1.001.10 1.111.28 1.291.41 1.421.58 1.591.80 1.812.03 2.042.25 2.262.51 2.522.83 2.843.29 3.303.75 3.764.22 4.234.65 4.665.16 5.175.53 5.546.09 6.106.80 6.817.60 7.618.35 8.369.00 3 T. U. 0.290.31 0.320.36 0.370.38 0.390.46 0.470.55 0.560.61 0.620.66 0.670.75 0.760.83 0.840.93 0.941.06 1.071.18 1.191.31 1.321.47 1.481.67 1.681.83 1.842.04 2.052.38 2.392.60 2.613.13 3.143.59 3.603.94 3.954.19 4.204.72 4.735.21 5.225.51 5.526.17 6.187.00 Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8
Table 56
Motor FLC (A) 1 or 2 T. U. 3.293.74 3.754.23 4.244.68 4.695.22 5.235.67 5.686.13 6.146.91 6.927.70 7.718.56 8.579.39 9.4010.4 10.511.6 11.712.9 13.014.6 14.716.5 16.618.5 18.621.0 21.123.6 23.726.3 26.429.3 29.435.1 35.236.1 36.239.1 39.241.5 41.645.0 3 T. U. 3.183.40 3.413.76 3.774.00 4.014.57 4.585.03 5.045.32 5.335.97 5.986.88 6.897.82 7.838.47 8.489.15 9.1610.1 10.211.2 11.312.0 12.113.6 13.715.2 15.317.1 17.219.0 19.121.5 21.624.1 24.227.0 27.128.7 28.830.4 30.532.2 32.335.4 35.538.2 38.345.0 Thermal Unit Number B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0 B 88.0
Non-Compensated 136.150. 227.251. AR 1.05 151.165. 252.276. AR 1.15 166.183. 277.305. AR 1.26 184.202. 306.337. AR 1.39 203.224. 338.373. AR 1.53 225.267. 374.445. AR 1.68 268.293. 446.489. AR 1.85 294.319. 490.532. AR 2.04 320.349. 533.582. AR 2.24 350.381. 583.636. AR 2.46 382.418. 637.697. AR 2.71 419.459. 698.766. AR 2.98 460.509. 767.849. AR 3.28 510.565. 850.942. AR 3.62 566.604. 943.1007. AR 3.98 605.697. 1008.1133. AR 4.37 698.753. AR 4.80 Compensated 161.177. 268.295. AR 1.26 178.196. 296.327. AR 1.39 197.217. 328.363. AR 1.53 218.253. 364.423. AR 1.68 254.277. 424.463. AR 1.85 278.301. 464.503. AR 2.04 302.325. 504.543. AR 2.24 326.354. 544.592. AR 2.46 355.381. 592.635. AR 2.71 382.419. 636.699. AR 2.98 420.467. 700.779. AR 3.28 468.529. 780.883. AR 3.62 530.594. 884.991. AR 3.98 595.664. 992.1107. AR 4.37 665.738. 1108.1231. AR 4.80 739.829. AR 5.3
Table 50
Motor FLC (A) 14.416.1 16.218.6 18.720.5 20.623.4 23.526.9 27.028.3 28.430.8 30.935.0 35.138.8 38.944.3 44.449.3 49.455.5 55.661.0 61.168.6 68.776.3 76.486.0 Thermal Unit Number AU 20.0 AU 23.0 AU 26.0 AU 29.0 AU 33.0 AU 38.0 AU 40.0 AU 44.0 AU 50.0 AU 56.0 AU 64.0 AU 72.0 AU 81.0 AU 88.0 AU 99.0 AU 110.0
Table 57
Motor FLC (A)) 2 T. U. 3 T. U. 5.155.97 5.986.50 6.517.04 7.057.59 7.607.93 7.949.04 9.0510.2 10.311.5 11.613.2 13.314.9 15.016.9 17.019.3 19.421.7 21.825.0 25.127.0 27.129.1 29.230.8 30.932.9 33.035.0 35.137.1 37.239.1 39.241.5 41.645.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0
Table 54
Motor FLC (A) 2 T. U. 43.645.5 45.649.6 49.753.1 53.257.6 57.762.4 62.567.5 67.671.1 71.275.9 76.081.9 82.084.6 84.790.7 90.898.4 98.5105. 106.117. 118.123. 124.133. 3 T. U. 41.143.5 43.646.8 46.950.0 50.154.9 55.057.5 57.661.8 61.966.2 66.372.4 72.578.1 78.280.7 80.886.5 86.693.9 94.0100. 101.112. 113.117. 118.123. 124.133. Thermal Unit Number CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0 CC 208.0 CC 219.0
Table 51
Motor FLC (A) 15.717.7 17.819.9 20.022.7 22.825.7 25.829.1 29.230.8 30.934.3 34.438.3 38.442.3 42.447.5 47.653.0 53.160.5 60.664.9 65.071.5 71.677.3 77.486.0 Thermal Unit Number AU 20.0 AU 23.0 AU 26.0 AU 29.0 AU 33.0 AU 38.0 AU 40.0 AU 44.0 AU 50.0 AU 56.0 AU 64.0 AU 72.0 AU 81.0 AU 88.0 AU 99.0 AU 110.0
Table 46
Motor FLC (A) 105.116. 117.132. 133.148. 149.165. 166.184. 185.207. 208.229. 230.266. Thermal Unit Number AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4
Table 44
Motor FLC (A) 0.340.38 0.390.43 0.440.48 0.490.53 0.540.62 0.630.69 0.700.78 0.790.88 0.890.99 1.001.10 1.111.26 1.271.43 1.441.59 1.601.81 1.822.00 2.012.28 2.292.52 2.532.87 2.883.28 3.293.75 3.764.27 4.284.77 4.785.27 5.285.91 5.926.25 6.266.83 6.847.65 7.668.55 8.569.56 9.5710.3 10.411.3 11.412.4 12.514.1 14.215.7 15.817.9 18.020.1 20.222.5 22.625.0 Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.65 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0
Table 55
Motor FLC (A) 2 T. U. 0.380.40 0.410.43 0.440.48 0.490.52 0.530.56 0.570.61 0.620.67 0.680.73 0.740.81 0.820.89 0.900.97 0.981.07 1.081.17 1.181.31 1.321.49 1.501.69 1.701.83 1.842.00 2.012.17 2.182.35 2.362.60 2.612.87 2.883.14 3.153.47 3.483.90 3.914.36 4.374.88 4.895.37 5.385.97 5.986.55 6.567.50 7.518.23 8.249.00 3 T. U. 0.310.33 0.340.36 0.370.39 0.400.43 0.440.47 0.480.51 0.520.56 0.570.58 0.590.64 0.650.70 0.710.77 0.780.85 0.860.94 0.951.03 1.041.22 1.231.34 1.351.46 1.471.58 1.591.76 1.771.85 1.862.08 2.092.27 2.282.51 2.522.90 2.913.23 3.243.58 3.594.02 4.034.43 4.444.86 4.875.37 5.386.12 6.136.65 6.667.00 Thermal Unit Number AR .45 AR .49 AR .54 AR .59 AR .65 AR .71 AR .78 AR .86 AR .95 AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3
5.095.59 5.606.11 6.126.72 6.737.37 7.387.67 7.688.68 8.699.94 9.9511.1 11.212.9 13.014.7 14.816.9 17.019.2 19.321.9 22.024.4 24.526.3 26.428.0 28.130.3 30.432.2 32.334.4 34.536.6 36.739.5 39.645.0
Table 47
Motor FLC (A) 146.169. 170.185. 186.201. 202.217. 218.236. 237.253. 254.279. 280.311. 312.353. 354.396. 397.442. 443.492. 493.520. Thermal Unit Number AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3
Table 58
Motor FLC (A) 1 or 2 T. U. 3.373.82 3.834.33 4.344.79 4.805.33 5.345.79 5.806.27 6.287.03 7.047.88 7.898.73 8.749.55 9.5610.6 10.711.8 11.913.1 13.214.9 15.016.9 17.018.8 18.921.5 21.624.1 24.226.8 26.929.9 30.035.5 35.636.5 36.639.6 39.741.5 41.645.0 3 T. U. 3.283.51 3.523.89 3.904.14 4.154.73 4.745.22 5.235.53 5.546.21 6.227.17 7.188.19 8.208.90 8.919.57 9.5810.6 10.711.8 11.912.7 12.814.4 14.516.1 16.218.2 18.320.2 20.322.8 22.925.6 25.728.8 28.930.6 30.732.4 32.534.6 34.738.6 38.745.0 Thermal Unit Number B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0
Table 52
Motor FLC (A) 92.0103. 104.116. 117.139. 140.150. 151.167. 168.177. 178.205. 206.222. 223.232. 233.247. 248.266. Thermal Unit Number AF 123.0 AF 135.0 AF 150.0 AF 159.0 AF 168.0 AF 188.0 AF 205.0 AF 220.0 AF 240.0 AF 260.0 AF 308.0
Table 48
Motor FLC (A) 158.187. 188.206. 207.224. 225.244. 245.267. 268.289. 290.324. 325.361. 362.406. 407.445. 446.463. 464.520. Thermal Unit Number AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80
16-135
16
Table 59
Motor FLC (A) 1 or 2 T. U. 0.340.38 0.390.43 0.440.47 0.480.53 0.540.60 0.610.68 0.690.76 0.770.86 0.870.97 0.981.07 1.081.23 1.241.39 1.401.55 1.561.77 1.781.96 1.972.15 2.162.41 2.422.71 2.723.03 3.043.53 3.544.01 4.024.56 4.575.03 5.045.59 5.605.95 5.966.58 6.597.31 7.328.15 8.169.13 9.149.91 9.9210.7 10.812.1 12.213.5 13.615.1 15.217.0 17.118.9 19.021.5 21.624.0 24.126.0 3 T. U. 0.290.31 0.320.35 0.360.38 0.390.46 0.470.55 0.560.62 0.630.67 0.680.75 0.760.84 0.850.95 0.961.09 1.101.21 1.221.35 1.361.53 1.541.73 1.741.90 1.912.14 2.152.34 2.352.67 2.683.22 3.233.48 3.493.87 3.884.14 4.154.73 4.745.28 5.295.64 5.656.39 6.407.43 7.448.55 8.569.40 9.4110.0 10.111.2 11.312.5 12.613.5 13.615.4 15.517.5 17.619.9 20.022.2 22.325.5 25.626.0 Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0
Table 62
Motor FLC (A) 2 T. U. 4.835.33 5.345.84 5.856.43 6.447.03 7.047.30 7.318.29 8.309.49 9.5010.7 10.812.3 12.414.0 14.116.0 16.118.4 18.521.0 21.123.0 23.125.5 25.626.7 26.828.3 28.430.3 30.432.5 32.634.5 34.637.6 37.739.7 39.841.4 41.545.0 3 T. U. 4.905.68 5.696.19 6.206.71 6.727.14 7.157.49 7.508.48 8.499.66 9.6710.8 10.912.4 12.513.9 14.015.7 15.818.1 18.220.3 20.423.0 23.125.2 25.326.6 26.728.2 28.330.2 30.332.3 32.434.3 34.436.7 36.839.3 39.445.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0 AR 94.0
Table 64
Motor FLC (A) 2 T. U. 2 T. U. 3 T. U. 1 2 0.380.40 0.380.40 0.310.33 AR .45 0.410.43 0.410.43 0.340.36 AR .49 0.440.48 0.440.48 0.370.39 AR .54 0.490.52 0.490.52 0.400.43 AR .59 0.530.56 0.530.56 0.440.47 AR .65 0.570.61 0.570.61 0.480.51 AR .71 0.620.67 0.620.67 0.520.56 AR .78 0.680.73 0.680.73 0.570.58 AR .86 0.740.81 0.740.81 0.590.64 AR .95 0.820.89 0.820.89 0.650.70 AR 1.05 0.900.97 0.900.97 0.710.77 AR 1.15 0.981.07 0.981.07 0.780.85 AR 1.26 1.081.17 1.081.17 0.860.94 AR 1.39 1.181.31 1.181.31 0.951.03 AR 1.53 1.321.49 1.321.49 1.041.22 AR 1.68 1.501.69 1.501.69 1.231.34 AR 1.85 1.701.83 1.701.83 1.351.46 AR 2.04 1.842.00 1.842.00 1.471.58 AR 2.24 2.012.17 2.012.17 1.591.76 AR 2.46 2.182.35 2.182.35 1.771.85 AR 2.71 2.362.60 2.362.60 1.862.08 AR 2.98 2.612.87 2.612.87 2.092.27 AR 3.28 2.883.14 2.883.14 2.282.51 AR 3.62 3.153.47 3.153.47 2.522.90 AR 3.98 3.483.90 3.483.90 2.913.23 AR 4.37 3.914.36 3.914.36 3.243.58 AR 4.80 4.374.88 4.374.88 3.594.02 AR 5.3 4.895.37 4.895.37 4.034.43 AR 5.8 5.385.97 5.385.97 4.444.86 AR 6.4 5.986.55 5.986.55 4.875.37 AR 7.0 6.567.50 6.567.50 5.386.12 AR 7.7 7.518.23 7.518.23 6.136.65 AR 8.5 8.248.99 8.248.99 6.667.31 AR 9.3 9.009.86 9.009.86 7.327.96 AR 10.2 9.8710.7 9.8710.7 7.978.69 AR 11.2 10.811.2 10.811.2 8.708.99 AR 12.4 11.312.8 11.312.0 9.0010.1 AR 13.6 12.914.8 10.211.5 AR 15.4 14.916.7 11.612.0 AR 17.6 16.818.0 AR 20.5 Following Selections for Size 1 Only. 11.312.8 AR 13.6 12.914.8 AR 15.4 14.916.7 11.613.0 AR 17.6 16.819.0 16.819.0 13.114.6 AR 20.5 19.122.0 19.122.0 14.716.5 AR 23.0 22.124.9 22.124.9 16.618.5 AR 27.0 25.026.0 25.026.0 18.621.0 AR 30.0 21.123.6 AR 35.0 23.726.0 AR 40.0 Thermal Unit No.
Table 65
Motor FLC (A) Thermal Unit Number 0.310.35 B 0.44 0.360.39 B 0.51 0.400.44 B 0.57 0.450.50 B 0.63 0.510.58 B 0.71 0.590.65 B 0.81 0.660.73 B 0.92 0.740.82 B 1.03 0.830.92 B 1.16 0.931.03 B 1.30 1.041.19 B 1.45 1.201.34 B 1.67 1.351.50 B 1.88 1.511.67 B 2.10 1.681.89 B 2.40 1.902.14 B 2.65 2.152.36 B 3.00 2.372.65 B 3.30 2.662.97 B 3.70 2.983.47 B 4.15 3.483.94 B 4.85 3.954.44 B 5.50 4.454.94 B 6.25 4.955.52 B 6.90 5.535.88 B 7.70 5.896.52 B 8.20 6.537.31 B 9.10 7.328.21 B 10.2 8.229.18 B 11.5 9.199.90 B 12.8 10.011.0 B 14.0 11.112.4 B 15.5 12.513.9 B 17.5 14.015.7 B 19.5 15.817.8 B 22.0 17.920.0 B 25.0 20.122.9 B 28.0 23.025.0 B 32.0 Following Selections for Size 2 Only. 23.025.7 B 32.0 25.828.6 B 36.0 28.732.2 B 40.0 32.335.8 B 45.0 35.940.1 B 50.0 40.244.4 B 56.0 44.550.0 B 62.0
Table 63
Motor FLC (A) 1 or 2 T. U. 15.117.0 17.119.1 19.221.8 21.924.5 24.627.9 28.029.5 29.632.9 33.036.6 36.740.3 40.445.1 45.250.4 50.557.3 57.462.4 62.568.3 68.473.9 74.080.6 80.786.0 Thermal Unit Number 3 T. U. AU 20.0 AU 23.0 AU 26.0 AU 29.0 AU 33.0 AU 38.0 AU 40.0 AU 44.0 AU 50.0 AU 56.0 AU 64.0 AU 72.0 AU 81.0 AU 88.0 AU 99.0 AU 110.0 AU 123.0
Table 60
Motor FLC (A) 6.847.49 7.508.05 8.069.10 9.119.99 10.011.1 11.212.7 12.814.8 14.916.6 16.719.3 19.421.4 21.525.1 25.228.3 28.431.2 31.333.3 33.435.7 35.838.5 38.641.5 41.645.0 Thermal Unit Number AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0
Table 66
Motor FLC (A) 0.310.32 0.330.36 0.370.41 0.420.49 0.500.54 0.550.61 0.620.67 0.680.76 0.770.87 0.880.98 0.991.05 1.061.25 1.261.33 1.341.56 1.571.71 1.721.97 1.982.15 2.162.42 2.432.78 2.793.28 3.293.88 3.894.13 4.144.43 4.444.96 4.975.35 5.365.91 5.926.79 6.807.56 7.577.83 7.848.09 8.109.51 9.5210.1 10.211.3 11.413.1 13.214.9 15.016.1 16.217.8 17.919.1 19.222.4 22.523.5 23.626.0 Thermal Unit Number B 0.44 B 0.51 B 0.57 B 0.63 B 0.71 B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.5 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0
Table 61
Motor FLC (A) 2 T. U. 46.850.0 50.154.2 54.358.3 58.463.6 63.768.5 68.674.0 74.179.8 79.983.0 83.188.9 89.095.6 95.7102. 103.109. 110.119. 120.133. 3 T. U. 45.348.2 48.352.4 52.556.4 56.561.2 61.366.1 66.271.4 71.577.0 77.179.0 79.184.7 84.891.1 91.298.1 98.2104. 105.113. 114.123. 124.133. Thermal Unit Number CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-136
Table 67
Motor FLC (A) 3.794.14 4.154.44 4.455.22 5.235.29 5.305.99 6.006.82 6.837.68 7.697.92 7.938.47 8.489.99 10.010.8 10.912.3 12.412.9 13.015.1 15.216.7 16.817.9 18.020.1 20.223.8 23.925.8 25.928.3 28.429.6 29.732.1 32.234.4 34.538.3 38.439.9 40.045.0 Thermal Unit Number B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0 B 88.0
Table 70
Motor FLC (A) 4.244.62 4.635.05 5.065.54 5.556.13 6.146.44 6.457.48 7.498.55 8.569.74 9.7511.1 11.212.7 12.814.4 14.516.4 16.518.9 19.021.6 21.723.3 23.424.9 25.026.9 27.029.1 29.231.3 31.433.5 33.636.9 37.039.1 39.240.9 41.045.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0 AR 94.0
Table 72
Motor FLC (A) 1 T. U. 3 T. U. 2.382.62 2.382.62 FB 3.33 2.632.94 2.632.94 FB 3.71 2.953.31 2.953.31 FB 4.1 3.323.43 3.323.43 FB 4.5 3.443.81 3.443.81 FB 4.75 3.824.32 3.824.32 FB 5.3 4.334.75 4.334.75 FB 6.1 4.765.38 4.765.38 FB 6.75 5.395.75 5.395.75 FB 7.45 5.765.97 5.765.97 FB 7.8 5.986.30 5.986.30 FB 8.21 6.316.55 6.316.55 FB 8.6 6.566.89 6.566.89 FB 9.0 6.907.14 6.907.14 FB 9.5 7.157.36 7.157.36 FB 10.0 7.378.30 7.378.30 FB 10.6 8.318.59 8.318.59 FB 11.2 8.609.01 8.609.01 FB 12.1 9.029.68 9.029.68 FB 13.1 9.699.99 9.699.99 FB 13.9 10.010.9 10.010.9 FB 14.8 11.011.3 11.011.3 FB 15.6 11.412.4 11.412.0 FB 16.4 12.512.9 FB 17.6 13.014.0 FB 18.4 14.114.5 FB 19.4 14.615.7 FB 21.1 15.816.6 FB 22.6 16.718.0 FB 23.6 Following Selections for Size M1 & M1P Only. 11.412.4 FB 16.4 12.512.9 FB 17.6 13.014.0 FB 18.4 14.114.5 FB 19.4 14.615.7 FB 21.1 15.816.6 FB 22.6 16.717.6 16.717.6 FB 23.6 17.718.3 17.718.3 FB 24.8 18.419.4 18.419.4 FB 26.7 19.520.5 19.520.5 FB 28.3 20.621.7 20.621.7 FB 29.6 21.822.8 21.822.8 FB 30.5 22.924.3 22.924.3 FB 32.5 24.424.7 24.424.7 FB 34.1 24.825.4 24.825.4 FB 35.0 25.526.0 25.526.0 FB 36.6 Following Selections for Size M1P Only. 26.127.7 FB 38.3 27.828.9 FB 40.2 29.030.6 FB 42.0 30.732.5 FB 44.0 32.636.0 FB 46.0 Thermal Unit Number
Table 73
Motor FLC (A) Thermal Unit Number 1 T. U. 3 T. U. 2.422.67 2.422.67 FB 3.33 2.683.00 2.683.00 FB 3.71 3.013.36 3.013.36 FB 4.1 3.373.53 3.373.53 FB 4.5 3.543.91 3.543.91 FB 4.75 3.924.41 3.924.41 FB 5.3 4.424.83 4.424.83 FB 6.1 4.845.45 4.845.45 FB 6.75 5.465.89 5.465.89 FB 7.45 5.906.04 5.906.04 FB 7.8 6.056.55 6.056.55 FB 8.21 6.566.72 6.566.72 FB 8.6 6.737.00 6.737.00 FB 9.0 7.017.39 7.017.39 FB 9.5 7.407.54 7.407.54 FB 10.0 7.558.41 7.558.41 FB 10.6 8.428.91 8.428.91 FB 11.2 8.929.16 8.929.16 FB 12.1 9.1710.0 9.1710.0 FB 13.1 10.110.3 10.110.3 FB 13.9 10.411.4 10.411.4 FB 14.8 11.511.8 11.511.8 FB 15.6 11.912.9 11.912.9 FB 16.4 13.013.4 FB 17.6 13.514.2 FB 18.4 14.315.1 FB 19.4 15.218.0 FB 21.1 Following Selections for Size M1 & M1P Only. 11.511.8 FB 15.6 11.912.9 FB 16.4 13.013.4 FB 17.6 13.514.2 FB 18.4 14.315.1 FB 19.4 15.217.1 15.217.1 FB 21.1 17.218.0 17.218.0 FB 22.6 18.118.9 18.118.9 FB 23.6 19.019.7 19.019.7 FB 24.8 19.820.9 19.820.9 FB 26.7 21.021.9 21.021.9 FB 28.3 22.023.1 22.023.1 FB 29.6 23.224.3 23.224.3 FB 30.5 24.425.5 24.425.5 FB 32.6 25.626.0 25.626.0 FB 34.1 Following Selections for Size M1P Only. 26.126.8 FB 35.0 26.927.3 FB 36.6 27.428.7 FB 38.3 28.830.2 FB 40.2 30.331.9 FB 42.0 32.036.0 FB 44.0
Table 71
Motor FLC (A) 3.984.53 4.545.03 5.045.46 5.476.01 6.026.31 6.327.19 7.208.29 8.309.49 9.5011.0 11.112.6 12.714.3 14.416.5 16.619.2 19.321.9 22.023.8 23.925.5 25.627.7 27.830.1 30.232.5 32.634.8 34.938.5 38.641.5 41.645.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0
Table 68
Motor FLC (A) 14.916.1 16.217.3 17.419.5 19.620.7 20.822.4 22.523.9 24.025.8 25.927.6 27.729.7 29.831.8 31.934.2 34.337.0 37.139.6 39.742.5 42.645.0 45.148.6 48.751.2 51.356.0 56.160.1 60.264.3 64.468.9 69.071.9 72.075.4 75.578.9 79.082.1 82.286.0 Thermal Unit Number CC 20.9 CC 22.8 CC 24.6 CC 26.3 CC 28.8 CC 31.0 CC 33.3 CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0
Table 69
Motor FLC (A) 1 or 2 T. U. 3.463.90 3.914.44 4.454.91 4.925.51 5.525.84 5.856.54 6.557.33 7.348.31 8.329.22 9.2310.0 10.111.2 11.312.5 12.614.2 14.316.1 16.218.4 18.520.5 20.623.2 23.326.6 26.729.6 29.733.5 33.637.2 37.341.5 41.645.0 3 T. U. 3.383.65 3.664.07 4.084.36 4.375.19 5.205.59 5.605.98 5.996.78 6.797.91 7.929.12 9.1310.0 10.110.7 10.812.0 12.113.5 13.614.6 14.716.7 16.818.9 19.021.6 21.724.1 24.227.6 27.731.2 31.335.5 35.637.8 37.941.5 41.645.0 Thermal Unit Number B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0
16-137
16
Table 74
Motor FLC (A) 1 T. U. 3 T. U. 2.232.47 2.232.47 FB 3.33 2.482.76 2.482.76 FB 3.71 2.773.04 2.773.04 FB 4.1 3.053.24 3.053.24 FB 4.5 3.253.61 3.253.61 FB 4.75 3.624.19 3.624.19 FB 5.3 4.204.62 4.204.62 FB 6.1 4.635.14 4.635.14 FB 6.75 5.155.39 5.155.39 FB 7.45 5.405.69 5.405.69 FB 7.8 5.705.99 5.705.99 FB 8.21 6.006.29 6.006.29 FB 8.6 6.306.64 6.306.64 FB 9.0 6.656.99 6.656.99 FB 9.5 7.007.39 7.007.39 FB 10.0 7.407.79 7.407.79 FB 10.6 7.807.94 7.807.94 FB 11.2 7.958.49 7.958.49 FB 12.1 8.508.99 8.508.99 FB 13.1 9.009.59 9.009.59 FB 13.9 9.6010.1 9.6010.1 FB 14.8 10.210.6 10.210.6 FB 15.6 10.711.3 10.711.3 FB 16.4 11.412.0 11.412.0 FB 17.6 12.012.6 FB 18.4 12.713.8 FB 19.4 13.914.7 FB 21.1 14.815.2 FB 22.6 15.316.2 FB 23.6 16.318.0 FB 24.8 Following Selections for Size 1 Only. 12.012.6 FB 18.4 12.713.8 FB 19.4 13.914.7 13.914.7 FB 21.1 14.815.2 14.815.2 FB 22.6 15.316.2 15.316.2 FB 23.6 16.317.4 16.317.4 FB 24.8 17.518.5 17.518.5 FB 26.7 18.619.6 18.619.6 FB 28.3 19.720.2 19.720.2 FB 29.6 20.321.5 20.321.5 FB 30.5 21.622.4 21.622.4 FB 32.6 22.523.2 22.523.2 FB 34.1 23.324.3 23.324.3 FB 35.0 24.425.4 24.425.4 FB 36.6 25.526.0 25.526.0 FB 38.3 Thermal Unit Number
Table 76
Motor FLC (A) 19.920.8 20.922.2 22.323.8 23.925.4 25.527.2 27.329.2 29.331.9 32.033.8 33.936.1 36.238.5 38.641.4 41.543.6 43.745.9 46.048.2 48.350.7 50.853.9 54.056.7 56.860.8 60.967.6 67.773.6 73.782.9 83.086.0 Thermal Unit Number FB 26.7 FB 28.3 FB 29.6 FB 30.5 FB 32.6 FB 34.1 FB 38.3 FB 40.2 FB 42.0 FB 44.0 FB 46.0 FB 48.0 FB 50.5 FB 52.5 FB 55.5 FB 58.0 FB 60.0 FB 63.5 FB 69.0 FB 77.0 FB 84.0 FB 92.0
Table 79
Motor FLC (A) 3.313.67 3.684.23 4.244.69 4.705.21 5.225.49 5.505.74 5.756.07 6.086.35 6.366.71 6.727.03 7.047.53 7.547.91 7.928.53 8.549.14 9.159.71 9.7210.2 10.310.8 10.911.5 11.612.3 12.413.0 13.113.9 14.015.1 15.216.1 16.216.9 17.017.9 18.019.4 19.520.7 20.821.7 21.822.3 22.423.9 24.025.1 25.225.9 26.027.1 27.228.6 28.730.1 30.231.7 31.833.3 33.434.5 34.636.5 36.638.5 38.639.9 40.045.0 Thermal Unit Number FB 4.75 FB 5.3 FB 6.1 FB 6.75 FB 7.45 FB 7.8 FB 8.21 FB 8.6 FB 9.0 FB 9.5 FB 10.0 FB 10.6 FB 11.2 FB 12.1 FB 13.1 FB 13.9 FB 14.8 FB 15.6 FB 16.4 FB 17.6 FB 18.4 FB 19.4 FB 21.1 FB 22.6 FB 23.6 FB 24.8 FB 26.7 FB 28.3 FB 29.6 FB 30.5 FB 32.6 FB 34.1 FB 35.0 FB 36.6 FB 38.3 FB 40.2 FB 42.0 FB 44.0 FB 46.0 FB 48.0 FB 50.5 FB 52.5
Table 81
Motor FLC (A) 52.255.6 55.758.8 58.962.5 62.666.0 66.170.1 70.278.6 78.792.0 92.1102 103114 115123 124133 Thermal Unit Number FB 50.5 FB 52.5 FB 55.5 FB 58.0 FB 60.0 FB 63.5 FB 69.0 FB 77.0 FB 84.0 FB 92.0 FB 105.0
Table 82
Motor FLC (A) 2.362.63 2.642.96 2.973.23 3.243.45 3.463.86 3.874.44 4.454.95 4.965.47 5.485.75 5.766.09 6.106.42 6.436.75 6.767.16 7.177.43 7.447.99 8.008.46 8.479.19 9.209.74 9.7510.3 10.410.8 10.911.6 11.712.2 12.313.1 13.213.7 13.814.3 14.415.5 15.616.7 16.817.6 17.718.6 18.719.9 20.021.1 21.225.0 Thermal Unit Number FB 3.33 FB 3.71 FB 4.1 FB 4.5 FB 4.75 FB 5.3 FB 6.1 FB 6.75 FB 7.45 FB 7.8 FB 8.21 FB 8.6 FB 9.0 FB 9.5 FB 10.0 FB 10.6 FB 11.2 FB 12.1 FB 13.1 FB 13.9 FB 14.8 FB 15.6 FB 16.4 FB 17.6 FB 18.4 FB 19.4 FB 21.1 FB 22.6 FB 23.6 FB 24.8 FB 92.0 FB 105.0
Table 77
Motor FLC (A) 48.050.9 51.053.7 53.857.0 57.160.4 60.564.0 64.171.9 72.083.9 84.093.1 93.2104 105109 110123 124133 Thermal Unit Number FB 50.5 FB 52.5 FB 55.5 FB 58.0 FB 60.0 FB 63.5 FB 69.0 FB 77.0 FB 84.0 FB 92.0 FB 105.0 FB 115.0
Table 78
Thermal Unit 2 T. U. or Number 3 T. U. 2.262.51 2.262.51 FB 3.33 2.522.82 2.522.82 FB 3.71 2.833.09 2.833.09 FB 4.1 3.103.30 3.103.30 FB 4.5 3.313.69 3.313.69 FB 4.75 3.704.27 3.704.27 FB 5.3 4.284.72 4.284.72 FB 6.1 4.735.25 4.735.25 FB 6.75 5.265.53 5.265.53 FB 7.45 5.545.81 5.545.81 FB 7.8 5.826.14 5.826.14 FB 8.21 6.156.44 6.156.44 FB 8.6 6.456.81 6.456.81 FB 9.0 6.827.19 6.827.19 FB 9.5 7.207.59 7.207.59 FB 10.0 7.607.99 7.607.99 FB 10.6 8.008.17 8.008.17 FB 11.2 8.188.74 8.188.74 FB 12.1 8.759.31 8.759.31 FB 13.1 9.329.94 9.329.94 FB 13.9 9.9510.5 9.9510.5 FB 14.8 10.611.1 10.611.1 FB 15.6 11.211.9 11.212.0 FB 16.4 12.012.4 FB 17.6 12.513.1 FB 18.4 13.214.3 FB 19.4 14.415.3 FB 21.1 15.415.9 FB 22.6 16.018.0 FB 23.6 Following Selections for Size 1 Only. 12.012.4 FB 17.6 12.513.1 FB 18.4 13.214.3 FB 19.4 14.415.3 14.415.3 FB 21.1 15.415.9 15.415.9 FB 22.6 16.016.9 16.016.9 FB 23.6 17.018.3 17.018.3 FB 24.8 18.419.5 18.419.5 FB 26.7 19.620.5 19.620.5 FB 28.3 20.621.1 20.621.1 FB 29.6 21.222.6 21.222.6 FB 30.5 22.723.7 22.723.7 FB 32.6 23.824.3 23.824.3 FB 35.0 24.426.0 24.426.0 1 T. U. Motor FLC (A)
Table 80
Motor FLC (A) 20.521.7 21.823.1 23.224.8 24.926.5 26.628.4 28.530.4 30.532.8 32.934.9 35.037.3 37.439.8 39.942.5 42.645.8 45.948.2 48.350.6 50.753.1 53.256.5 56.659.4 59.563.4 63.571.0 71.178.8 78.986.0 Thermal Unit Number FB 26.7 FB 28.3 FB 29.6 FB 30.5 FB 32.6 FB 34.1 FB 38.3 FB 40.2 FB 42.0 FB 44.0 FB 46.0 FB 48.0 FB 50.5 FB 52.5 FB 55.5 FB 58.0 FB 60.0 FB 63.5 FB 69.0 FB 77.0 FB 84.0
Table 75
Motor FLC (A) 3.223.57 3.584.14 4.154.56 4.575.10 5.115.39 5.405.64 5.655.96 5.976.25 6.266.58 6.596.91 6.927.41 7.427.82 7.838.32 8.338.89 8.909.47 9.4810.0 10.110.5 10.611.1 11.212.0 12.112.7 12.813.5 13.614.6 14.715.7 15.816.5 16.617.4 17.518.8 18.920.1 20.221.0 21.121.6 21.723.3 23.424.3 24.425.0 25.126.3 26.427.6 27.729.1 29.230.4 30.532.0 32.133.3 33.435.2 35.337.0 37.138.5 38.640.7 40.845.0 Thermal Unit Number FB 4.75 FB 5.3 FB 6.1 FB 6.75 FB 7.45 FB 7.8 FB 8.21 FB 8.6 FB 9.0 FB 9.5 FB 10.0 FB 10.6 FB 11.2 FB 12.1 FB 13.1 FB 13.9 FB 14.8 FB 15.6 FB 16.4 FB 17.6 FB 18.4 FB 19.4 FB 21.1 FB 22.6 FB 23.6 FB 24.8 FB 26.7 FB 28.3 FB 29.6 FB 30.5 FB 32.6 FB 34.1 FB 35.0 FB 36.6 FB 38.3 FB 40.2 FB 42.0 FB 44.0 FB 46.0 FB 48.0 FB 50.5 FB 52.5 FB 55.5
Table 83
Motor FLC (A) 2.302.60 2.612.87 2.883.17 3.183.37 3.383.76 3.774.29 4.304.75 4.765.26 5.275.51 5.525.78 5.796.13 6.146.41 6.426.75 6.767.09 7.107.57 7.587.90 7.918.81 8.829.47 9.4810.0 10.110.7 10.811.4 11.512.1 12.213.1 13.213.7 13.814.7 14.816.0 16.117.3 17.418.2 18.319.4 19.520.7 20.822.3 22.423.5 23.624.2 24.326.0 Thermal Unit Number FB 3.33 FB 3.71 FB 4.1 FB 4.5 FB 4.75 FB 5.3 FB 6.1 FB 6.75 FB 7.45 FB 7.8 FB 8.21 FB 8.6 FB 9.0 FB 9.5 FB 10.0 FB 10.6 FB 11.2 FB 12.1 FB 13.1 FB 13.9 FB 14.8 FB 15.6 FB 16.4 FB 17.6 FB 18.4 FB 19.4 FB 21.1 FB 22.6 FB 23.6 FB 24.8 FB 26.7 FB 28.3 FB 29.6 FB 30.5
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-138
Table 84
Motor FLC (A) 3.383.78 3.794.37 4.384.87 4.885.51 5.525.73 5.746.09 6.106.44 6.456.75 6.767.15 7.167.57 7.588.07 8.088.47 8.488.81 8.829.46 9.4710.1 10.210.8 10.911.4 11.512.1 12.213.1 13.213.8 13.914.8 14.916.1 16.217.4 17.518.3 18.419.5 19.621.0 21.122.5 22.623.7 23.824.5 24.626.4 26.527.7 27.828.7 28.829.9 30.031.8 31.933.5 33.635.1 35.237.1 37.238.8 38.941.1 41.245.0 Thermal Unit Number FB 4.75 FB 5.3 FB 6.1 FB 6.75 FB 7.45 FB 7.8 FB 8.21 FB 8.6 FB 9.0 FB 9.5 FB 10.0 FB 10.6 FB 11.2 FB 12.1 FB 13.1 FB 13.9 FB 14.8 FB 15.6 FB 16.4 FB 17.6 FB 18.4 FB 19.4 FB 21.1 FB 22.6 FB 23.6 FB 24.8 FB 26.7 FB 28.3 FB 29.6 FB 30.5 FB 32.6 FB 34.1 FB 35.0 FB 36.6 FB 38.3 FB 40.2 FB 42.0 FB 44.0 FB 46.0 FB 48.0
Table 86
Motor FLC (A) 0.430.44 0.450.47 0.480.53 0.540.61 0.620.65 0.660.71 0.720.79 0.800.86 0.870.96 0.971.04 1.051.17 1.181.31 1.321.38 1.391.47 1.481.57 1.581.65 1.661.77 1.781.93 1.942.18 2.192.46 2.472.68 2.692.87 2.883.07 3.083.59 3.603.79 3.804.27 4.284.59 4.604.90 4.915.06 5.075.44 5.456.24 6.257.21 7.227.69 7.708.24 8.258.81 8.829.32 9.339.99 10.010.5 10.611.5 11.612.2 12.313.3 13.415.8 15.918.4 18.520.5 20.621.5 21.623.9 24.026.8 26.928.2 28.329.8 29.932.0 Thermal Unit Number A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .95 A 1.02 A 1.16 A 1.25 A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 A 11.0 A 11.9 A 132 A 14.1 A 14.8 A 16.2 A 17.9 A 21.3 A 25.2 A 27.1 A 29.5 A 31.9 A 33.8 A 35.9 A 40.0 A 42.3 A 44.7
Table 88
Motor FLC (A) 0.390.40 0.410.44 0.450.49 0.500.57 0.580.61 0.620.66 0.670.73 0.740.80 0.810.90 0.910.97 0.981.09 1.101.23 1.241.57 1.581.66 1.671.79 1.801.99 2.002.31 2.322.50 2.512.66 2.672.85 2.863.26 3.273.49 3.503.92 3.934.20 4.214.49 4.504.64 4.654.94 4.955.62 5.636.39 6.406.82 6.837.27 7.287.71 7.728.13 8.148.64 8.659.15 9.169.97 9.9811.0 Thermal Unit Number A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .95 A 1.02 A 1.16 A 1.25 A 1.39 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9
Table 91
Motor FLC (A) 4.805.07 5.085.73 5.746.48 6.496.90 6.917.25 7.267.81 7.828.29 8.308.81 8.829.40 9.4110.0 10.111.1 11.211.7 11.813.7 13.816.0 16.116.9 17.017.7 17.818.7 18.820.2 20.321.4 21.522.5 22.623.8 23.926.0 Thermal Unit Number A 7.65 A 8.38 A 9.25 A 9.85 A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9 A 21.3 A 25.2 A 27.1 A 29.5 A 31.9 A 33.8 A 35.9 A 40.0 A 42.3 A 44.7 A 48.0
Table 92
Motor FLC (A) 10.511.7 11.812.5 12.614.0 14.115.8 15.918.0 18.119.6 19.723.5 23.627.4 27.530.5 30.632.2 32.334.0 34.135.2 35.339.5 39.643.9 44.048.0 Thermal Unit Number B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0 B 88.0
Table 89
Motor FLC (A) 10.011.1 11.212.0 12.113.3 13.415.1 15.217.1 17.218.6 18.721.4 21.525.7 25.828.2 28.329.7 29.831.2 31.332.1 32.235.7 35.840.7 40.848.0 Thermal Unit Number B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0 B 88.0
Table 85
Motor FLC (A) 42.945.4 45.648.3 48.452.4 52.555.9 56.059.8 59.963.8 63.967.9 68.072.6 72.783.2 83.394.7 94.8105 106116 117121 122133 Thermal Unit Number FB 44.0 FB 46.0 FB 48.0 FB 50.5 FB 52.5 FB 55.5 FB 58.0 FB 60.0 FB 63.5 FB 69.0 FB 77.0 FB 84.0 FB 92.0 FB 105.0
Table 93
Motor FLC (A) 23.825.2 25.326.8 26.928.4 28.530.3 30.432.1 32.234.2 34.336.3 36.440.2 40.343.1 43.245.9 46.049.2 49.351.6 51.754.2 54.355.7 55.860.3 60.463.5 63.667.1 67.270.3 70.474.1 74.278.3 78.483.3 83.486.0 Thermal Unit Number CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0
Table 87
Motor FLC (A) 0.400.41 0.420.45 0.460.51 0.520.58 0.590.63 0.640.68 0.690.76 0.770.83 0.840.93 0.941.01 1.021.14 1.151.28 1.291.34 1.351.44 1.451.55 1.561.61 1.621.71 1.721.85 1.862.04 2.052.38 2.392.60 2.612.77 2.782.98 2.993.40 3.413.64 3.654.08 4.094.38 4.394.68 4.694.79 4.805.11 5.125.84 5.856.70 6.717.18 7.197.70 7.718.14 8.158.56 8.579.15 9.169.80 9.8110.6 10.711.0 Thermal Unit Number A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .95 A 1.02 A 1.16 A 1.25 A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9
Table 90
Motor FLC (A) 4.885.13 5.145.85 5.866.67 6.687.09 7.107.62 7.638.04 8.058.46 8.479.11 9.129.69 9.7010.5 10.611.6 11.712.3 12.414.6 14.716.8 16.917.9 18.018.7 18.819.8 19.921.4 21.522.8 22.923.8 23.926.0 Thermal Unit Number A 7.65 A 8.38 A 9.25 A 9.85 A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9 A 21.3 A 25.2 A 27.1 A 29.5 A 31.9 A 33.8 A 35.9 A 40.0 A 42.3 A 44.7
16-139
16
Table 94
Motor FLC (A) 25.827.5 27.629.4 29.531.4 31.533.2 33.336.2 36.338.8 38.941.6 41.744.7 44.847.9 48.050.9 51.054.4 54.557.4 57.560.6 60.763.9 64.068.4 68.573.4 73.578.7 78.883.8 83.986.0 Thermal Unit Number CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0
Table 97
Motor FLC (A) 0.570.60 0.610.66 0.670.73 0.740.81 0.820.90 0.911.05 1.061.15 1.161.25 1.261.35 1.361.47 1.481.58 1.591.74 1.751.94 1.952.20 2.212.47 2.482.76 2.773.07 3.083.45 3.463.81 3.824.20 4.214.65 4.665.29 5.305.84 5.856.27 6.286.97 6.987.59 7.607.89 7.908.95 8.9610.3 10.411.7 11.813.3 13.415.2 15.317.2 17.319.7 19.822.4 22.526.0 Thermal Unit Number AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0
Table 99
Motor FLC (A) 27.130.0 30.133.2 33.335.7 35.839.4 39.543.4 43.546.9 47.051.5 51.657.0 57.162.8 62.969.1 69.275.0 75.183.3 Thermal Unit Number E 67 E 69 E 70 E 71 E 72 E 73 E 74 E 76 E 77 E 78 E 79 E 80
Table 100
Motor FLC (A) 5055.9 5660.9 9165.9 6669.9 7075.9 7681.9 8286.9 8792.9 9397.9 98107.9 108113.9 114125.9 Thermal Unit Number E 88 E 89 E 91 E 92 E 93 E 94 E 96 E 97 E 98 E 99 E 101 E 102
Table 95
Motor FLC (A) 42.544.7 44.847.9 48.051.2 51.355.2 55.359.4 59.563.8 63.968.8 68.973.8 73.977.7 77.882.5 82.686.6 86.791.9 92.097.2 97.3104 105114 115123 124150 Thermal Unit Number CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0 CC 208.0 CC 219.0
Table 101
Motor FLC (A) 105116 117132 133148 149165 166184 185207 208229 230266 Thermal Unit Number AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4
Table 98
Motor FLC (A) 4.244.62 4.635.05 5.065.54 5.556.13 6.146.44 6.457.48 7.498.55 8.569.74 9.7511.1 11.212.7 12.814.4 14.516.4 16.518.9 19.021.6 21.723.3 23.424.9 25.026.9 27.029.1 29.231.3 31.433.5 33.636.9 37.039.1 39.240.9 41.045.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0 AR 94.0
Table 96
Motor FLC (A) 49.552.0 52.154.8 54.958.7 58.863.3 63.468.3 68.473.6 73.779.4 79.585.5 85.689.7 89.894.8 94.999.9 100105 106111 112126 127131 132141 142150 Thermal Unit Number CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0 CC 208.0 CC 219.0
Table 102
Motor FLC (A) 146169 170185 186201 202217 218236 237253 254279 280311 312353 354396 397442 443492 493520 Thermal Unit Number AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-140
Table 103
Motor FLC (A) 40.845.5 45.649.9 51.057.5 57.665.9 66.073.1 73.281.5 81.692.3 92.4104 105114 115128 129140 141160 161193 194209 210232 233248 249266 Thermal Unit Number B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90
Table 105
Motor FLC (A) 105112 113122 123131 132142 143153 154157 158169 170181 182195 196209 210227 228247 248266 Thermal Unit Number CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0 CC 196.0
Table 109
Motor FLC (A) 0.560.63 0.640.68 0.690.77 0.780.85 0.860.97 0.981.09 1.101.21 1.221.33 1.341.53 1.541.73 1.741.89 1.902.17 2.182.53 2.542.87 2.883.22 3.233.49 3.503.85 3.864.11 4.124.70 4.715.21 5.225.53 5.546.17 6.187.02 7.037.92 7.938.61 8.629.17 9.1810.0 10.111.0 11.111.8 11.913.5 13.615.3 15.417.4 17.519.4 19.522.2 22.325.1 25.227.0 Thermal Unit Number B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0
Table 104
Motor FLC (A) 0.650.73 0.740.82 0.930.91 0.921.04 1.051.16 1.171.26 1.271.47 1.481.65 1.661.89 1.902.17 2.182.49 2.502.79 2.803.13 3.143.36 3.373.69 3.703.92 3.934.42 4.434.99 5.005.27 5.285.84 5.856.61 6.627.42 7.438.02 8.038.53 8.549.34 9.3510.1 10.210.8 10.912.0 12.113.0 13.115.5 Thermal Unit No. B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 Max. Fuse Rating (A) 1.50 1.50 1.60 2.00 2.00 2.25 2.60 3.00 3.50 4.00 4.50 5.00 5.60 6.00 7.00 7.00 8.00 9.00 10.0 12.0 12.0 15.0 15.0 15.0 17.5 17.5 20.0 25.0 25.0 30.0 600 V 250 V Max. Max. 30 30 30 40 30 40 30 40
Table 110
Motor FLC (A) 3.944.45 4.464.97 4.985.28 5.295.97 5.986.89 6.907.92 7.938.71 8.729.27 9.2810.2 10.311.4 11.512.3 12.413.9 14.015.8 15.917.9 18.019.9 20.022.8 22.925.4 25.528.9 29.030.8 30.932.5 32.634.9 35.039.7 39.844.7 Thermal Unit Number B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0
16-141
16
Table 111
Motor FLC (A) 14.014.9 15.016.2 16.317.2 17.318.7 18.820.2 20.321.7 21.823.3 23.425.2 25.327.1 27.229.4 29.531.6 31.734.0 34.136.8 36.939.8 39.942.3 42.445.7 45.849.2 49.352.8 52.956.8 56.961.2 61.366.1 66.271.2 71.376.7 76.882.9 83.090.0 Thermal Unit Number CC 20.9 CC 22.8 CC 24.6 CC 26.3 CC 28.8 CC 31.0 CC 33.3 CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0
Table 114
Motor FLC (A) 133148 149174 175195 196219 220239 240271 272308 309348 349397 398429 430495 496520 Thermal Unit Number B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85
Table 115
Motor FLC (A) 176190 191203 203223 224239 240253 254299 300341 342361 362395 396409 410427 428475 476487 488532 Thermal Unit Number DD 112.0 DD 121.0 DD 128.0 DD 140.0 DD 150.0 DD 160.0 DD 185.0 DD 220.0 DD 240.0 DD 250.0 DD 265.0 DD 289.0 DD 300.0 DD 320.0
Table 112
Motor FLC (A) 44.046.8 46.950.6 50.754.5 54.658.4 58.562.9 63.067.7 67.872.9 73.078.1 78.283.9 84.091.1 91.297.5 97.6104 105113 114133 Thermal Unit Number CC 64.3 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0 CC 156.0 CC 167.0 CC 180.0
Table 116
Motor FLC (A)) 81.691.1 91.2101 102115 116131 132146 147163 164184 185209 210229 230257 258281 282321 322387 388419 420465 466497 496532 Thermal Unit Number B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.35 B 5.60 B 6.25 B 6.90
Table 113
Motor FLC (A) 88.295.1 95.2101 102111 112119 120131 132149 150170 171180 181197 198204 205213 214237 238243 244266 Thermal Unit Number DD 112.0 DD 121.0 DD 128.0 DD 140.0 DD 150.0 DD 160.0 DD 185.0 DD 220.0 DD 240.0 DD 250.0 DD 265.0 DD 280.0 DD 300.0 DD 320.0
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-142
Table 117
Motor FLC (A) 100111.9 112121.9 122131.9 132139.9 140151.9 152163.9 164173.9 174185.9 186195.9 196215.9 216227.9 228251.9 Thermal Unit Number E 88 E 89 E 91 E 92 E 93 E 94 E 96 E 97 E 98 E 99 E 101 E 102
Table 122
Motor FLC (A) 8.489.25 9.2610.11 10.1211.09 11.1012.27 12.2812.89 12.9014.97 14.9817.11 17.1219.49 19.5022.3 22.422.5 22.628.9 29.032.9 33.037.9 38.043.3 43.446.7 46.849.9 50.053.9 54.058.3 58.462.7 62.867.1 67.273.8 74.078.3 78.481.9 82.090.0 Thermal Unit Number AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0 AR 44.0 AR 47.0 AR 51.0 AR 55.0 AR 60.0 AR 66.0 AR 72.0 AR 79.0 AR 86.0 AR 94.0
Table 118
Motor FLC (A) 210233 234265 266297 298331 332369 370415 416459 460532 Thermal Unit Number AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.8 AR 5.3 AR 5.8 AR 6.4
Table 123
Motor FLC (A) 54.260.1 60.266.5 66.671.5 71.678.9 79.086.9 87.093.9 94.0103.1 103.2114.1 114.2125.7 125.8138.3 138.4150.1 150.2166.6 Thermal Unit Number E 67 E 69 E 70 E 71 E 72 E 73 E 74 E 76 E 77 E 78 E 79 E 80
Table 121
Motor FLC (A) 1.141.21 1.221.33 1.341.47 1.481.63 1.641.81 1.822.11 2.122.31 2.322.51 2.522.71 2.722.95 2.963.17 3.183.49 3.503.89 3.904.41 4.424.95 4.965.53 5.546.15 6.166.91 6.927.63 7.648.41 8.429.31 9.3210.59 10.6011.69 11.7012.55 12.5613.95 13.9615.19 15.2015.79 15.8017.91 17.9220.7 20.823.5 23.626.7 26.830.5 30.634.5 34.639.5 39.644.9 45.052.0 Thermal Unit Number AR 1.05 AR 1.15 AR 1.26 AR 1.39 AR 1.53 AR 1.68 AR 1.85 AR 2.04 AR 2.24 AR 2.46 AR 2.71 AR 2.98 AR 3.28 AR 3.62 AR 3.98 AR 4.37 AR 4.80 AR 5.3 AR 5.8 AR 6.4 AR 7.0 AR 7.7 AR 8.5 AR 9.3 AR 10.2 AR 11.2 AR 12.4 AR 13.6 AR 15.4 AR 17.6 AR 20.5 AR 23.0 AR 27.0 AR 30.0 AR 35.0 AR 40.0
Table 127
Motor FLC (A) 1.121.27 1.281.37 1.381.55 1.561.71 1.721.95 1.962.19 2.202.43 2.442.67 2.683.07 3.083.47 3.483.79 3.804.35 4.365.07 5.085.75 5.766.45 6.466.99 7.007.71 7.728.23 8.249.41 9.4210.43 10.4411.07 11.0812.35 12.3614.05 14.0615.85 15.8617.23 17.2418.35 18.3620.1 20.222.1 22.223.7 23.827.1 27.230.7 30.834.9 35.038.9 39.044.5 44.650.3 50.454.0 Thermal Unit Number B 0.81 B 0.92 B 1.03 B 1.16 B 1.30 B 1.45 B 1.67 B 1.88 B 2.10 B 2.40 B 2.65 B 3.00 B 3.30 B 3.70 B 4.15 B 4.85 B 5.50 B 6.25 B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0
16-143
16
Table 128
Motor FLC (A) 7.888.91 8.929.95 9.9610.57 10.5811.95 11.9613.79 13.8015.85 15.8617.43 17.4418.55 18.5620.5 20.622.9 23.024.7 24.827.9 28.031.7 31.835.9 36.039.9 40.045.7 45.850.9 51.061.7 61.865.1 65.269.9 70.079.5 79.689.4 Thermal Unit Number B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0
Table 133
Motor FLC (A) 4.605.23 5.245.86 5.876.25 6.267.09 7.108.25 8.269.49 9.5010.3 10.411.2 11.312.5 12.613.8 13.915.0 15.116.9 17.019.1 19.222.0 22.124.4 24.528.0 28.131.8 31.936.0 36.138.5 38.641.2 41.344.4 44.550.3 50.456.9 57.059.0 Thermal Unit Number B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0 B 88.0
Table 129
Motor FLC (A) 28.029.9 30.032.5 32.634.5 34.637.5 37.640.5 40.643.5 43.646.7 46.850.5 50.654.3 54.458.9 59.063.3 63.468.1 68.273.7 73.879.7 79.884.7 84.891.5 91.698.5 98.6105.7 105.8113.7 113.8122.5 122.6132.3 132.4142.5 142.6153.5 153.6165.9 166.0180.0 Thermal Unit Number CC 20.9 CC 22.8 CC 24.6 CC 26.3 CC 28.8 CC 31.0 CC 33.3 CC 36.4 CC 39.6 CC 42.7 CC 46.6 CC 50.1 CC 54.5 CC 59.4 CC 64.5 CC 68.5 CC 74.6 CC 81.5 CC 87.7 CC 94.0 CC 103.0 CC 112.0 CC 121.0 CC 132.0 CC 143.0
Table 134
Motor FLC (A) 4.304.98 4.995.57 5.585.94 5.956.71 6.727.79 7.808.93 8.949.77 9.7810.5 10.611.7 11.813.0 13.114.0 14.115.0 15.117.2 17.319.9 20.022.3 22.426.0 26.129.8 29.934.0 34.136.7 36.839.5 39.642.1 42.246.6 46.751.5 51.654.0 Thermal Unit Number B 6.90 B 7.70 B 8.20 B 9.10 B 10.2 B 11.5 B 12.8 B 14.0 B 15.5 B 17.5 B 19.5 B 22.0 B 25.0 B 28.0 B 32.0 B 36.0 B 40.0 B 45.0 B 50.0 B 56.0 B 62.0 B 70.0 B 79.0 B 88.0
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-144
Table 135
Thermal Unit Number 1 T. U. 3 T. U. 0.770.88 0.850.95 B 1.30 0.891.02 0.961.09 B 1.45 1.031.19 1.101.21 B 1.67 1.201.37 1.221.35 B 1.88 1.381.62 1.361.56 B 2.10 1.631.90 1.571.76 B 2.40 1.912.12 1.771.94 B 2.65 2.132.46 1.952.22 B 3.00 2.472.83 2.232.57 B 3.30 2.843.19 2.582.87 B 3.70 3.203.61 2.883.21 B 4.15 3.623.89 3.223.50 B 4.85 3.904.32 3.513.79 B 5.50 4.334.57 3.804.04 B 6.25 4.585.19 4.054.53 B 6.90 5.205.79 4.545.03 B 7.70 5.806.16 5.045.36 B 8.20 6.176.94 5.375.97 B 9.10 6.957.99 5.986.89 B 10.2 7.808.99 6.907.79 B 11.5 9.009.98 7.808.53 B 12.8 9.9910.6 8.549.09 B 14.0 10.711.6 9.109.99 B 15.5 11.713.1 10.010.9 B 17.5 13.214.2 11.011.7 B 19.5 14.315.4 11.813.4 B 22.0 15.517.6 13.515.4 B 25.0 17.720.0 15.517.9 B 28.0 18.020.0 B 32.0 For Type DPSG12 & DPSG13, 20 Ampere Starter. Select Thermal Units from above. 20.122.7 18.020.2 B 32.0 22.825.0 20.323.2 B 36.0 23.325.0 B 40.0 For Type DPSG22 & DPSG23, 25 Ampere Starter. Select any of the Thermal Units from above. 22.826.1 B 36.0 26.229.6 23.325.8 B 40.0 29.730.0 25.928.6 B 45.0 28.729.7 B 50.0 29.830.0 B 56.0 For Type DPSG32 & DPSG33, 30 Ampere Starter. Select any of the Thermal Units from above. Motor FLC (A)
Table 137
Motor FLC (A) 5055.9 5660.9 6165.9 6669.9 7075.9 7681.9 8286.9 8792.9 9397.9 98107 108113 114125 126138 139153 154163 164180 Thermal Unit Number E 88 E 89 E 91 E 92 E 93 E 94 E 96 E 97 E 98 E 99 E 101 E 102 E 103 E 104 E 106 E 107
Table 138
Motor FLC (A) 22.625.5 25.626.4 26.528.9 29.031.9 32.034.5 34.636.9 37.040.6 40.744.0 44.147.4 47.553.1 53.258.3 58.463.5 63.669.9 70.077.1 77.283.3 83.486.9 87.092.9 93.0100 Thermal Unit Number E 62 E 65 E 66 E 67 E 69 E 70 E 71 E 72 E 73 E 74 E 76 E 77 E 78 E 79 E 80 E 96 E 97 E 98
Table 139
Motor FLC (A) 13.715.2 15.316.8 16.918.7 18.820.0 20.122.5 22.623.3 23.425.5 25.627.9 28.030.8 30.933.2 33.336.6 36.738.9 39.043.1 43.247.4 47.550.0 50.155.2 55.360.0 Thermal Unit Number E 57 E 59 E 60 E 61 E 62 E 65 E 66 E 67 E 69 E 70 E 71 E 72 E 73 E 74 E 76 E 77 E 78
Table 136
Motor FLC (A) Thermal Unit Number 1 T. U. 3 T. U. 0.981.09 0.880.98 B 1.30 1.101.24 0.991.13 B 1.45 1.251.41 1.141.26 B 1.67 1.421.59 1.271.38 B 1.88 1.601.81 1.391.62 B 2.10 1.822.04 1.631.82 B 2.40 2.052.19 1.832.04 B 2.65 2.202.52 2.052.36 B 3.00 2.532.90 2.372.72 B 3.30 2.913.29 2.733.07 B 3.70 3.303.69 3.083.44 B 4.15 3.703.99 3.453.69 B 4.85 4.004.42 3.704.11 B 5.50 4.434.69 4.124.34 B 6.25 4.705.37 4.354.89 B 6.90 5.385.94 4.905.44 B 7.70 5.956.34 5.455.80 B 8.20 6.357.05 5.816.47 B 9.10 7.068.14 6.487.45 B 10.2 8.159.39 7.468.49 B 11.5 9.4010.3 8.509.29 B 12.8 10.411.1 9.309.99 B 14.0 11.212.2 10.010.8 B 15.5 12.313.5 10.912.1 B 17.5 13.614.7 12.213.1 B 19.5 14.816.1 13.214.6 B 22.0 16.218.3 14.716.4 B 25.0 18.420.0 16.518.9 B 28.0 19.020.0 B 32.0 For Type DPSO12 & DPSO13, 20 Ampere Starter. Select Thermal Units from above. 18.420.9 B 28.0 21.023.6 19.020.9 B 32.0 23.725.0 21.024.1 B 36.0 24.225.0 B 40.0 For Type DPSO22 & DPSO23, 25 Ampere Starter. Select any of the Thermal Units from above. B 36.0 23.727.2 24.227.2 B 40.0 27.330.0 27.330.0 B 45.0 For Type DPSO32 & DPSO33, 30 Ampere Starter. Select any of the Thermal Units from above.
16-145
16
Table 140
Motor FLC (A) 0.340.36 0.370.40 0.410.43 0.440.47 0.480.51 0.520.56 0.570.62 0.630.67 0.680.73 0.740.77 0.780.84 0.850.93 0.941.00 1.011.08 1.091.15 1.161.27 1.281.45 1.461.61 1.621.81 1.822.00 2.012.12 2.132.29 2.302.43 2.442.66 2.672.98 2.993.16 3.173.39 3.403.69 3.704.00 4.014.48 4.495.00 5.015.44 5.455.99 6.006.60 6.616.96 6.977.26 7.277.99 8.008.89 8.909.74 9.7510.50 10.611.5 11.612.3 12.413.4 13.515.2 15.317.2 17.318.4 18.520.6 20.721.3 21.423.4 23.524.0 Thermal Unit Number E3 E4 E5 E6 E7 E8 E9 E 11 E 12 E 13 E 14 E 16 E 17 E 18 E 19 E 23 E 24 E 26 E 27 E 28 E 29 E 31 E 32 E 33 E 34 E 36 E 37 E 38 E 39 E 41 E 42 E 44 E 46 E 47 E 48 E 49 E 50 E 51 E 52 E 53 E 54 E 55 E 56 E 57 E 60 E 61 E 62 E 65 E 66 E 67
Table 142
Motor FLC (A) 11.713.5 13.616.7 16.818.1 18.220.0 20.121.9 22.024.2 24.326.2 26.329.2 29.332.0 32.134.3 34.436.2 36.339.9 40.043.8 43.946.2 46.350.0 Thermal Unit No. E56 E57 E60 E61 E62 E65 E66 E67 E69 E70 E71 E73 E73A E74 E76 600 V Max. 100 100 100 100 100 100 100 100 Max. Fuse Rating (A) 25 30 35 40 40 45 50 50 60 70 70 80 90 90 100 250 V Max. 110 110 125 125 125 125 125 125
Table 143
Motor FLC (A) 18.920.0 20.122.8 22.924.7 24.826.9 27.029.2 29.332.8 32.934.9 35.037.5 37.639.6 39.746.1 46.249.9 50.056.3 56.461.0 61.164.0 64.166.0 66.172.4 72.578.2 78.383.9 84.086.0 86.192.8 92.997.9 98.0105.0 105.1117.0 117.1133.0 Thermal Unit No. E60 E61 E62 E65 E66 E67 E69 E70 E72 E73 E73A E74 E76 E77 E78 E79 E80 E94 E96 E97 E98 E101 E102 E103 Max. Fuse Rating (A) 40 45 50 50 60 60 70 70 80 80 100 110 125 125 125 125 150 175 175 175 200 200 200 200
Table 141
Motor FLC (A) 12.214.4 14.517.8 17.918.8 18.921.4 21.523.0 23.125.7 25.828.0 28.131.0 31.132.7 32.835.5 35.638.2 38.343.3 43.446.9 47.050.1 Thermal Unit No. E56 E57 E60 E61 E62 E65 E66 E67 E69 E70 E71 E73 E73A E74 600 V Max. 100 100 100 100 100 100 100 100 Max. Fuse Rating (A) 25 30 40 40 45 50 50 60 60 70 80 80 90 100 250 V Max. 110 110 125 125 125 125 125 125
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-146
Table 144
Motor FLC (A) 18.219.1 19.222.1 22.223.1 23.225.7 25.827.7 27.831.3 31.433.3 33.435.9 36.038.4 38.544.2 44.346.8 46.952.6 52.756.0 56.158.4 58.561.9 62.067.1 67.272.3 72.475.9 76.085.6 85.791.2 91.3100.0 100.1108.9 109.0119.9 120.0133.0 Thermal Unit No. E60 E61 E62 E65 E66 E67 E69 E70 E71 E73 E73A E74 E76 E77 E78 E79 E80 E94 E96 E98 E101 E102 E103 E104 Max. Fuse Rating (A) 40 40 45 50 50 60 70 70 80 80 90 100 110 125 125 125 150 150 150 175 200 200 200 200
Table 146
Motor FLC (A) Thermal Unit Number 1 T.U. 3 T.U. 3.904.22 3.603.89 B5.50 4.234.49 3.904.15 B6.25 4.505.14 4.164.76 B6.90 5.155.78 4.775.30 B7.70 5.796.23 5.315.70 B8.20 6.247.03 5.716.46 B9.10 7.048.23 6.477.65 B10.2 8.249.31 7.668.55 B11.5 9.3210.1 8.569.36 B12.8 10.210.7 9.379.9 B14.0 10.811.9 10.010.9 B15.5 12.013.1 11.012.0 B17.5 13.213.9 12.112.8 B19.5 14.015.9 12.914.2 B22.0 16.018.0 14.316.0 B25.0 18.120.8 16.118.5 B28.0 20.923.1 18.621.2 B32.0 23.226.9 21.324.9 B36.0 27.031.4 25.028.0 B40.0 31.536.0 28.131.7 B45.0 36.138.8 31.834.6 B50.0 38.941.7 34.737.4 B56.0 41.846.3 37.540.0 B62.0 46.450.0 40.146.4 B70.0 46.550.0 B79.0 For Type DPSG52 & DPSG53, 50 Ampere Starter. Select any of the Thermal Units from above.
Table 145
Motor FLC (A) 1 T.U. 3 T.U. 1.001.11 0.911.02 B1.30 1.121.27 1.031.15 B1.45 1.281.36 1.161.27 B1.67 1.371.53 1.281.39 B1.88 1.541.78 1.401.61 B2.10 1.792.02 1.621.84 B2.40 2.032.20 1.852.03 B2.65 2.212.52 2.042.34 B3.00 2.532.94 2.352.69 B3.30 2.953.30 2.703.02 B3.70 3.313.70 3.033.39 B4.15 3.714.02 3.403.65 B4.85 4.034.46 3.664.04 B5.50 4.474.69 4.054.28 B6.25 4.705.37 4.294.85 B6.90 5.385.94 4.865.38 B7.70 5.956.34 5.395.71 B8.20 6.357.09 5.726.39 B9.10 7.108.46 6.407.53 B10.2 8.479.32 7.548.34 B11.5 9.3310.2 8.359.14 B12.8 10.310.9 9.159.74 B14.0 11.012.1 9.7510.7 B15.5 12.213.4 10.811.8 B17.5 13.514.2 11.912.2 B19.5 14.316.0 12.314.4 B22.0 16.118.1 14.516.4 B25.0 18.220.5 16.518.9 B28.0 20.623.5 19.021.3 B32.0 23.627.2 21.423.3 B36.0 27.330.8 23.427.9 B40.0 30.935.0 28.031.4 B45.0 35.137.2 31.532.5 B50.0 37.340.0 32.636.5 B56.0 36.640.0 B62.0 For Type DPSG42 & DPSG43, 40 Ampere Starter. Select any of the Thermal Units from above. Thermal Unit Number
Table 147
Motor FLC (A) Thermal Unit Number 1 T.U. 3 T.U. 1.041.14 0.931.04 B1.30 1.151.29 1.051.18 B1.45 1.301.43 1.191.33 B1.67 1.441.56 1.341.43 B1.88 1.571.79 1.441.67 B2.10 1.802.03 1.681.88 B2.40 2.042.26 1.892.09 B2.65 2.272.51 2.102.41 B3.00 2.523.03 2.422.79 B3.30 3.043.31 2.803.15 B3.70 3.323.73 3.163.54 B4.15 3.744.07 3.553.75 B4.85 4.084.49 3.764.22 B5.50 4.504.76 4.234.46 B5.25 4.775.44 4.475.09 B6.90 5.456.04 5.105.61 B7.70 6.056.46 5.625.99 B8.20 6.477.24 6.006.70 B9.10 7.258.64 6.718.19 B10.20 8.659.59 8.208.79 B11.5 9.6010.5 8.809.66 B12.8 10.611.3 9.6710.2 B14.0 11.412.6 10.311.4 B15.5 12.713.9 11.512.6 B17.5 14.014.9 12.713.5 B19.5 15.016.5 13.615.1 B22.0 16.618.9 15.217.2 B25.0 19.022.2 17.319.9 B28.0 22.324.6 20.022.5 B32.0 24.728.6 22.626.2 B36.0 28.732.4 26.329.9 B40.0 32.537.3 30.034.0 B45.0 37.439.5 34.136.2 B50.0 39.640.0 36.338.7 B56.0 38.840.0 B62.0 For Type DPSO42 & DPSO43, 40 Ampere Starter. Select any of the Thermal Units from above.
16-147
16
Table 148
Motor FLC (A) 1 T.U. 3 T.U. 4.144.45 3.704.09 B5.50 4.464.88 4.104.35 B6.25 4.895.44 4.365.07 B6.90 5.456.08 5.085.79 B7.70 6.096.42 5.806.27 B8.20 6.437.28 6.287.16 B9.10 7.298.42 7.178.58 B10.2 8.439.64 8.599.55 B11.5 9.6510.4 9.5610.2 B12.8 10.511.2 10.310.9 B14.0 11.312.3 11.011.9 B15.5 12.413.7 12.013.1 B17.5 13.814.8 13.214.0 B19.5 14.916.5 14.114.8 B22.0 16.618.7 14.917.0 B25.0 18.821.4 17.119.6 B28.0 21.524.3 19.722.1 B32.0 24.428.0 22.226.0 B36.0 28.133.3 26.129.4 B40.0 33.437.6 29.534.0 B45.0 37.741.1 34.136.4 B50.0 41.244.1 36.539.2 B56.0 44.247.8 39.342.4 B62.0 47.950.0 42.549.3 B70.0 49.450.0 B79.0 For Type DPSO52 & DPSO53, 50 Ampere Starter. Select any of the Thermal Units from above. Thermal Unit Number
Table 150
Motor FLC (A) Max. Fuse Rating (Amp) 14.615.5 CC20.9 30 15.616.6 CC22.8 35 16.718.5 CC24.6 35 18.620.1 CC26.3 40 20.221.8 CC28.8 45 21.923.6 CC31.0 45 23.725.1 CC33.3 50 25.227.2 CC36.4 50 27.329.2 CC39.6 60 29.331.4 CC42.7 60 31.533.8 CC46.6 70 33.936.5 CC50.1 70 36.639.1 CC54.5 80 39.242.3 CC59.4 80 42.444.9 CC64.3 90 45.050.6 CC68.5 100 50.751.9 CC74.6 100 52.056.1 CC81.5 100 56.260.7 CC87.7 100 60.864.1 CC94.0 100 64.269.5 CC103.0 100 69.673.6 CC112.0 100 73.776.7 CC121.0 100 76.881.6 CC132.0 100 81.784.6 CC143.0 100 84.788.0 CC156.0 110 88.190.0 CC167.0 110 For Type DPSO60 to 90 Ampere Starter. Select any of the Thermal Units from above. Thermal Unit
Table 149
Motor FLC (A) Max. Fuse Rating (Amp) 14.615.3 CC20.9 30 15.416.2 CC22.8 30 16.318.0 CC24.6 35 18.119.5 CC26.3 40 19.621.0 CC28.8 40 21.123.0 CC31.0 45 23.124.2 CC33.3 50 24.326.0 CC36.4 50 26.127.9 CC39.6 50 28.029.9 CC42.7 60 30.032.6 CC46.6 60 32.734.6 CC50.1 70 34.736.5 CC54.5 70 36.640.0 CC59.4 80 40.142.4 CC64.3 90 42.548.1 CC68.5 90 48.248.6 CC74.6 100 48.752.6 CC81.5 100 52.756.5 CC87.7 100 56.659.5 CC94.0 100 59.664.4 CC103.0 100 64.567.4 CC112.0 100 67.569.6 CC121.0 100 69.774.2 CC132.0 100 74.378.0 CC143.0 100 78.182.1 CC156.0 100 82.287.5 CC167.0 110 87.690.0 CC180.0 110 For Type DPSG60 to 90 Ampere Starter. Select any of the Thermal Units from above. Thermal Unit
16
NEMA DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS
16-148
Table of Contents
Section 17
Model 6 Motor Control Centers
Structure and Unit Features Merchandised Units General Information Combination Starters with Motor Circuit Protector Disconnects Combination Starters with Fusible Switch Disconnects Compac
6 Combination Starters
Overview
Designed and manufactured to tackle the toughest power and process control challenges, the Model 6 Motor Control Center features industry-finest innovations that provide unmatched performance, high reliability, and low maintenance. The Model 6 Motor Control Center has integrated industry-leading components into the smallest and most flexible footprint possible to meet your power, control, and automation needs. The Model 6 provides superior performance, as well as long, reliable operation with enhanced safety features.
Model 6 Unit
17-1
17
Model 6 MCC
17
MOTOR CONTROL CENTERS Model 6 Motor Control Center Model 6
Model 6 Structure Features Horizontal main bus uses captive splice bar assembly; allows splicing without removing units Horizontal bus is located at the top of the structure for easy installation, inspection and maintenance
Available ampacity 600 A, 800 A, 1200 A, 2000 A and 2500 A Sliding non-conductive bus barrier 300 A and 600 A vertical bus Vertical bus openings built on 3-inch centers Optional automatic vertical bus shutters are available Mounting channel includes leveling notches for ease of alignment Full depth vertical wireway available, either 4-inch or 9-inch width Vertical ground bus is standard
Model 6 Unit Features Cast metal handle, color coded for clear indication of disconnect position (including Tripped) Twin-handle cam (Butterfly) mechanism standard on all plug-on units (except Compac 6) Rugged unit construction features solid rear, side and hinged bottom plates Forward tilted pull-apart control terminal blocks standard with NEMA Type B or C wiring Starter units available with Class 8536 Type S NEMA or D-Line IEC Available overload relays on starter include: melting alloy, bimetallic, Motor Logic, Motor Logic Plus , and Motor Logic Plus II Control station plate for pilot devices is mounted on front of unit (no cables across door hinge) Easily accessible control transformer Starter mounted on right-hand side of unit, adjacent to wireway, for ease of cable termination
Available units include:
Automation equipment Altivar AC drives Altistart soft starts TVSS units PowerLogic circuit monitor and power meter Compac 6 starters and branch feeders Reduced voltage starters Distribution transformers and panelboards Empty mounting units Master terminal compartments Automatic transfer switches Full voltage non-reversing Full voltage reversing Circuit breaker branch feeders Fusible switch branch feeders Full voltage 2-speed Programmable logic controllers Incoming devices
Transparent Ready
Motor Control Centers with PowerLogic circuit monitors and Web-enabled Ethernet communication devices are a part of Schneider Electrics Transparent Ready power equipment family. When specified as Transparent Ready, the power equipment is provided with a factory configured plug and play communications system that gives authorized users access to equipment status and monitoring information using only a standard Web browser. Ask your nearest Schneider Electric sales office for details about Transparent Ready power distribution equipment.
Merchandised Units
Model 6 Industrial Package units (white) are available for ordering by catalog number. A listing of types available by quick shipment may be found on the following pages. This limited offering includes popular combinations of types and options. Catalog numbers consist of class number (8998), disconnect and device types, horsepower or ampacity ratings and options (for example, 8998SBA001XFTMA). See table below. All units are UL Listed.
Model 6 Industrial Package, 480 V, 60 Hz, NEMA 12 enclosure Type 1B wiring, 100,000 AIR rating, 1 N.O./1 N.C. auxiliary interlock on each contactor
Table 17.1:
First 8998 Class
Numbering System
Third B Disconnect Fifth Sixth 005 A Motor Pilot Device Device Hp Function 001=1 hp 002=2 hp 003=3 hp 005=5 hp 007=7.5 hp 010=10 hp X=None A-FVNR C-FVRb 015=15 hpb A=Start-Stop PB, On/Off Lightsc 025=25 hpb C=HOA Sel.Switch, On/Off Lightsa 040=40 hpb 050=50 hpb 060=60 hpb 075=75 hpb 100=100 hpb Fourth A Seventh FT Control Power Eighth MA Overload Relay
Second S Type
8998
MA-Melting Alloy (Thermal Units not Included) SS-Motor Logic SSOL (Class 20 Base Unit)
a b c d
Not available with FVR Not available with Compac 6 Includes forward, reverse and stop push-buttons; and forward and reverse pilot lights with FVR starters Includes extra 50 VA CPT on Sz 1 FVNR (T1)
For more information, contact your nearest Schneider Electric sales office. Complete Model 6 Motor Control Centers are available from the factory. 17-2
2009 Schneider Electric All Rights Reserved
Model 6 MCC
www.schneider-electric.us
Combination Starters
Class 8998 / Refer to Catalog 8998CT9701
Model 6 NEMA-rated FVNR combination starters use PowerPact Motor Circuit Protectors. Ratings: 480 V, NEMA 12, Type 1B-D wiring, 100,000 AIR. Units include 1 N.O./1 N.C. auxiliary contacts. Units with pilot devices use 22 mm type. Units without pilot devices include a station plate with knockouts for five 22 mm devices. Thermal units are not included with melting alloy overloads. Table 17.2:
Ratings
NEMA Max. Space Catalog Number $ Price Catalog Number $ Price Size Hp (IN)
Full Voltage Non-Reversing (FVNR) Starters With Motor Circuit Protector Disconnect and Melting Alloy Overload Relay 1 SBA001XFTMA SBA001AFTMA SBA001CFTMA SBA001XFSMA SBA001AFSMA 2 SBA002XFTMA SBA002AFTMA SBA002CFTMA SBA002XFSMA SBA002AFSMA 3 SBA003XFTMA SBA003AFTMA SBA003CFTMA SBA003XFSMA BA003AFSMA 1 12 2988.00 3530.00 3530.00 2672.00 5 SBA005XFTMA SBA005AFTMA SBA005CFTMA SBA005XFSMA SBA005AFSMA 7.5 SBA007XFTMA SBA007AFTMA SBA007CFTMA SBA007XFSMA SBA007AFSMA 10 SBA010XFTMA SBA010AFTMA SBA010CFTMA SBA010XFSMA SBA010AFSMA 15 SBA015XFTMA SBA015AFTMA SBA015CFTMA SBA015XFSMA SBA015AFSMA 2 12 3322.00 3864.00 3864.00 3006.00 25 SBA025XFTMA SBA025AFTMA SBA025CFTMA SBA025XFSMA SBA025AFSMA 40 SBA040XFTMA SBA040AFTMA SBA040CFTMA SBA040XFSMA SBA040AFSMA 3 18 4798.00 5340.00 5340.00 4362.00 50 SBA050XFTMA SBA050AFTMA SBA050CFTMA SBA050XFSMA SBA050AFSMA 60 SBA060XFTMA SBA060AFTMA SBA060CFTMA SBA060XFSMA SBA060AFSMA 4 21 75 SBA075XFTMA 6644.00 SBA075AFTMA 7186.00 SBA075CFTMA 7186.00 SBA075XFSMA 6086.00 SBA075AFSMA 100 SBA100XFTMA SBA100AFTMA SBA100CFTMA SBA100XFSMA SBA100AFSMA Full Voltage Non-Reversing (FVNR) Starters With Motor Circuit Protector Disconnect and Solid State Overload Relay (Motor Logic) 1 SBA001XFTSS SBA001AFTSS SBA001CFTSS SBA001XFSSS SBA001AFSSS 2 SBA002XFTSS SBA002AFTSS SBA002CFTSS SBA002XFSSS SBA002AFSSS 3 SBA003XFTSS SBA003AFTSS SBA003CFTSS SBA003XFSSS SBA003AFSSS 1 12 3184.00 3726.00 3726.00 2868.00 5 SBA005XFTSS SBA005AFTSS SBA005CFTSS SBA005XFSSS SBA005AFSSS 7.5 SBA007XFTSS SBA007AFTSS SBA007CFTSS SBA007XFSSS SBA007AFSSS 10 SBA010XFTSS SBA010AFTSS SBA010CFTSS SBA010XFSSS SBA010AFSSS 15 SBA015XFTSS SBA015AFTSS SBA015CFTSS SBA015XFSSS SBA015AFSSS 2 12 3518.00 4060.00 4060.00 3202.00 25 SBA025XFTSS SBA025AFTSS SBA025CFTSS SBA025XFSSS SBA025AFSSS 40 SBA040XFTSS SBA040AFTSS SBA040CFTSS SBA040XFSSS SBA040AFSSS 3 18 5074.00 5616.00 5616.00 4638.00 50 SBA050XFTSS SBA050AFTSS SBA050CFTSS SBA050XFSSS SBA050AFSSS 60 SBA060XFTSS SBA060AFTSS SBA060CFTSS SBA060XFSSS SBA060AFSSS 4 75 21 SBA075XFTSS 6920.00 SBA075AFTSS 7462.00 SBA075CFTSS 7462.00 SBA075XFSSS 6362.00 SBA075AFSSS 100 SBA100XFTSS SBA100AFTSS SBA100CFTSS SBA100XFSSS SBA100AFSSS
3410.00
SBA001CFSSS SBA002CFSSS SBA003CFSSS SBA005CFSSS SBA007CFSSS SBA010CFSSS SBA015CFSSS SBA025CFSSS SBA040CFSSS SBA050CFSSS SBA060CFSSS SBA075CFSSS SBA100CFSSS
3410.00
Table 17.3:
Ratings NEMA Size Max. Hp
Full Voltage Reversing (FVR) Starters With Motor Circuit Protector Disconnect and Melting Alloy Overload Relay 1 SBC001XFTMA SBC001AFTMA SBC001XFSMA 2 SBC002XFTMA SBC002AFTMA SBC002XFSMA 3 SBC003XFTMA SBC003AFTMA SBC003XFSMA 1 18 3884.00 4494.00 5 SBC005XFTMA SBC005AFTMA SBC005XFSMA 7.5 SBC007XFTMA SBC007AFTMA SBC007XFSMA 10 SBC010XFTMA SBC010AFTMA SBC010XFSMA 15 SBC015XFTMA SBC015AFTMA SBC015XFSMA 2 18 4760.00 5370.00 25 SBC025XFTMA SBC025AFTMA SBC025XFSMA 40 SBC040XFTMA SBC040AFTMA SBC040XFSMA 3 27 6246.00 6856.00 50 SBC050XFTMA SBC050AFTMA SBC050XFSMA 60 SBC060XFTMA SBC060AFTMA SBC060XFSMA 4 75 33 SBC075XFTMA 9826.00 SBC075AFTMA 10436.00 SBC075XFSMA 100 SBC100XFTMA SBC100AFTMA SBC100XFSMA Full Voltage Reversing (FVR) Starters With Motor Circuit Protector Disconnect and Solid State Overload Relay (Motor Logic) 1 SBC001XFTSS SBC001AFTSS SBC001XFSSS 2 SBC002XFTSS SBC002AFTSS SBC002XFSSS 3 SBC003XFTSS SBC003AFTSS SBC003XFSSS 1 18 4160.00 4690.00 5 SBC005XFTSS SBC005AFTSS SBC005XFSSS 7.5 SBC007XFTSS SBC007AFTSS SBC007XFSSS 10 SBC010XFTSS SBC010AFTSS SBC010XFSSS 15 SBC015XFTSS SBC015AFTSS SBC015XFSSS 2 18 5116.00 5566.00 25 SBC025XFTSS SBC025AFTSS SBC025XFSSS 40 SBC040XFTSS SBC040AFTSS SBC040XFSSS 3 27 6682.00 7132.00 50 SBC050XFTSS SBC050AFTSS SBC050XFSSS 60 SBC060XFTSS SBC060AFTSS SBC060XFSSS 4 75 33 SBC075XFTSS 10102.00 SBC075AFTSS 10712.00 SBC075XFSSS 100 SBC100XFTSS SBC100AFTSS SBC100XFSSS
3568.00
SBC001AFSMA SBC002AFSMA SBC003AFSMA SBC005AFSMA SBC007AFSMA SBC010AFSMA SBC015AFSMA SBC025AFSMA SBC040AFSMA SBC050AFSMA SBC060AFSMA SBC075AFSMA SBC100AFSMA SBC001AFSSS SBC002AFSSS SBC003AFSSS SBC005AFSSS SBC007AFSSS SBC010AFSSS SBC015AFSSS SBC025AFSSS SBC040AFSSS SBC050AFSSS SBC060AFSSS SBC075AFSSS SBC100AFSSS
4178.00
3764.00
4374.00
PE4A
Discount Schedule
17-3
17
3214.00
SBA001CFSMA SBA002CFSMA SBA003CFSMA SBA005CFSMA SBA007CFSMA SBA010CFSMA SBA015CFSMA SBA025CFSMA SBA040CFSMA SBA050CFSMA SBA060CFSMA SBA075CFSMA SBA100CFSMA
3214.00
Model 6 MCC
Combination Starters
Class 8998 / Refer to Catalog 8998CT9701
www.schneider-electric.us
17
MOTOR CONTROL CENTERS
Full Voltage Non-Reversing (FVNR) Starters With Fusible Switch Disconnect and Melting Alloy Overload Relay 1 SFA001XFTMA SFA001AFTMA SFA001CFTMA SFA001XFSMA 2 SFA002XFTMA SFA002AFTMA SFA002CFTMA SFA002XFSMA 3 SFA003XFTMA SFA003AFTMA SFA003CFTMA SFA003XFSMA 1 12 2330.00 2872.00 2872.00 2014.00 5 SFA005XFTMA SFA005AFTMA SFA005CFTMA SFA005XFSMA 7.5 SFA007XFTMA SFA007AFTMA SFA007CFTMA SFA007XFSMA 10 SFA010XFTMA SFA010AFTMA SFA010CFTMA SFA010XFSMA 15 SFA015XFTMA SFA015AFTMA SFA015CFTMA SFA015XFSMA 2 12 2750.00 3292.00 3292.00 2434.00 25 SFA025XFTMA SFA025AFTMA SFA025CFTMA SFA025XFSMA 40 SFA040XFTMA SFA040AFTMA SFA040CFTMA SFA040XFSMA 3 18 3960.00 4502.00 4502.00 3524.00 50 SFA050XFTMA SFA050AFTMA SFA050CFTMA SFA050XFSMA 60 SFA060XFTMA SFA060AFTMA SFA060CFTMA SFA060XFSMA 4 75 30 SFA075XFTMA 6344.00 SFA075AFTMA 6886.00 SFA075CFTMA 6886.00 SFA075XFSMA 5786.00 100 SFA100XFTMA SFA100AFTMA SFA100CFTMA SFA100XFSMA Full Voltage Non-Reversing (FVNR) Starters With Fusible Switch Disconnect and Solid State Overload Relay (Motor Logic) 1 SFA001XFTSS SFA001AFTSS SFA001CFTSS SFA001XFSSS 2 SFA002XFTSS SFA002AFTSS SFA002CFTSS SFA002XFSSS 3 SFA003XFTSS SFA003AFTSS SFA003CFTSS SFA003XFSSS 1 12 2526.00 3068.00 3068.00 2210.00 5 SFA005XFTSS SFA005AFTSS SFA005CFTSS SFA005XFSSS 7.5 SFA007XFTSS SFA007AFTSS SFA007CFTSS SFA007XFSSS 10 SFA010XFTSS SFA010AFTSS SFA010CFTSS SFA010XFSSS 15 SFA015XFTSS SFA015AFTSS SFA015CFTSS SFA015XFSSS 2 12 2946.00 3488.00 3488.00 2630.00 25 SFA025XFTSS SFA025AFTSS SFA025CFTSS SFA025XFSSS 40 SFA040XFTSS SFA040AFTSS SFA040CFTSS SFA040XFSSS 3 18 4236.00 4778.00 4778.00 3800.00 50 SFA050XFTSS SFA050AFTSS SFA050CFTSS SFA050XFSSS 60 SFA060XFTSS SFA060AFTSS SFA060CFTSS SFA060XFSSS 4 75 30 SFA075XFTSS 6620.00 SFA075AFTSS 7162.00 SFA075CFTSS 7162.00 SFA075XFSSS 6062.00 100 SFA100XFTSS SFA100AFTSS SFA100CFTSS SFA100XFSSS
SFA001AFSMA SFA002AFSMA SFA003AFSMA SFA005AFSMA SFA007AFSMA SFA010AFSMA SFA015AFSMA SFA025AFSMA SFA040AFSMA SFA050AFSMA SFA060AFSMA SFA075AFSMA SFA100AFSMA SFA001AFSSS SFA002AFSSS SFA003AFSSS SFA005AFSSS SFA007AFSSS SFA010AFSSS SFA015AFSSS SFA025AFSSS SFA040AFSSS SFA050AFSSS SFA060AFSSS SFA075AFSSS SFA100AFSSS
2556.00
SFA001CFSMA SFA002CFSMA SFA003CFSMA SFA005CFSMA SFA007CFSMA SFA010CFSMA SFA015CFSMA SFA025CFSMA SFA040CFSMA SFA050CFSMA SFA060CFSMA SFA075CFSMA SFA100CFSMA SFA001CFSSS SFA002CFSSS SFA003CFSSS SFA005CFSSS SFA007CFSSS SFA010CFSSS SFA015CFSSS SFA025CFSSS SFA040CFSSS SFA050CFSSS SFA060CFSSS SFA075CFSSS SFA100CFSSS
2556.00
2752.00
2752.00
Table 17.5:
Ratings NEMA Size Max. Hp
Full Voltage Reversing (FVR) Starters With Fusible Switch Disconnect and Melting Alloy Overload Relay 1 SFC001XFTMA SFC001AFTMA SFC001XFSMA 2 SFC002XFTMA SFC002AFTMA SFC002XFSMA 3 SFC003XFTMA SFC003AFTMA SFC003XFSMA 1 18 3322.00 3932.00 5 SFC005XFTMA SFC005AFTMA SFC005XFSMA 7.5 SFC007XFTMA SFC007AFTMA SFC007XFSMA 10 SFC010XFTMA SFC010AFTMA SFC010XFSMA 15 SFC015XFTMA SFC015AFTMA SFC015XFSMA 2 18 4460.00 5070.00 25 SFC025XFTMA SFC025AFTMA SFC025XFSMA 40 SFC040XFTMA SFC040AFTMA SFC040XFSMA 3 27 6328.00 6938.00 50 SFC050XFTMA SFC050AFTMA SFC050XFSMA 60 SFC060XFTMA SFC060AFTMA SFC060XFSMA 4 75 39 SFC075XFTMA 10358.00 SFC075AFTMA 10968.00 SFC075XFSMA 100 SFC100XFTMA SFC100AFTMA SFC100XFSMA Full Voltage Reversing (FVR) Starters with Fusible Switch Disconnect and Solid State Overload Relay (Motor Logic) 1 SFC001XFTSS SFC001AFTSS SFC001XFSSS 2 SFC002XFTSS SFC002AFTSS SFC002XFSSS 3 SFC003XFTSS SFC003AFTSS SFC003XFSSS 1 18 3518.00 4128.00 5 SFC005XFTSS SFC005AFTSS SFC005XFSSS 7.5 SFC007XFTSS SFC007AFTSS SFC007XFSSS 10 SFC010XFTSS SFC010AFTSS SFC010XFSSS 15 SFC015XFTSS SFC015AFTSS SFC015XFSSS 2 18 4656.00 5266.00 25 SFC025XFTSS SFC025AFTSS SFC025XFSSS 40 SFC040XFTSS SFC040AFTSS SFC040XFSSS 3 27 6604.00 7214.00 50 SFC050XFTSS SFC050AFTSS SFC050XFSSS 60 SFC060XFTSS SFC060AFTSS SFC060XFSSS 4 75 39 SFC075XFTSS 10634.00 SFC075AFTSS 11244.00 SFC075XFSSS 100 SFC100XFTSS SFC100AFTSS SFC100XFSSS
3006.00
SFC001AFSMA SFC002AFSMA SFC003AFSMA SFC005AFSMA SFC007AFSMA SFC010AFSMA SFC015AFSMA SFC025AFSMA SFC040AFSMA SFC050AFSMA SFC060AFSMA SFC075AFSMA SFC100AFSMA SFC001AFSSS SFC002AFSSS SFC003AFSSS SFC005AFSSS SFC007AFSSS SFC010AFSSS SFC015AFSSS SFC025AFSSS SFC040AFSSS SFC050AFSSS SFC060AFSSS SFC075AFSSS SFC100AFSSS
3616.00
3202.00
3812.00
17-4
PE4A
Discount Schedule
Model 6 MCC
www.schneider-electric.us
NEMA-rated Compac 6, half-height FVNR combination starters use GJ frame Mag-Gard Motor Circuit Protectors. Ratings: 480 V, NEMA 12, Type 1B-D wiring, 100,000 AIR. Units include 1 N.O./1 N.C. auxiliary contacts. Units with pilot devices use 22 mm type. Units without pilot devices include a station plate with knockouts for four 22 mm devices. Thermal units are not included with melting alloy overloads. Table 17.6:
Ratings
Full Voltage Non-Reversing (FVNR) Starters With Motor Circuit Protector Disconnect and Melting Alloy Overload Relay 1 HBA001XFTMA HBA001AFTMA HBA001CFTMA HBA001XFSMA HBA001AFSMA 2 HBA002XFTMA HBA002AFTMA HBA002CFTMA HBA002XFSMA HBA002AFSMA 3 HBA003XFTMA HBA003AFTMA HBA003CFTMA HBA003XFSMA HBA003AFSMA 1 6 2860.00 3402.00 3402.00 2544.00 3086.00 5 HBA005XFTMA HBA005AFTMA HBA005CFTMA HBA005XFSMA HBA005AFSMA 7.5 HBA007XFTMA HBA007AFTMA HBA007CFTMA HBA007XFSMA HBA007AFSMA 10 HBA010XFTMA HBA010AFTMA HBA010CFTMA HBA010XFSMA HBA010AFSMA Full Voltage Non-Reversing (FVNR) Starters With Motor Circuit Protector Disconnect and Solid State Overload Relay (Motor Logic) 1 HBA001XFTSS HBA001AFTSS HBA001CFTSS HBA001XFSSS HBA001AFSSS 2 HBA002XFTSS HBA002AFTSS HBA002CFTSS HBA002XFSSS HBA002AFSSS 3 HBA003XFTSS HBA003AFTSS HBA003CFTSS HBA003XFSSS HBA003AFSSS 1 6 3056.00 3598.00 3598.00 2740.00 3282.00 5 HBA005XFTSS HBA005AFTSS HBA005CFTSS HBA005XFSSS HBA005AFSSS 7.5 HBA007XFTSS HBA007AFTSS HBA007CFTSS HBA007XFSSS HBA007AFSSS 10 HBA010XFTSS HBA010AFTSS HBA010CFTSS HBA010XFSSS HBA010AFSSS
HBA001CFSMA HBA002CFSMA HBA003CFSMA 3086.00 HBA005CFSMA HBA007CFSMA HBA010CFSMA HBA001CFSSS HBA002CFSSS HBA003CFSSS HBA005CFSSS HBA007CFSSS HBA010CFSSS
3282.00
Full Voltage Non-Reversing (FVNR) Starters with Fusible Switch Disconnect and Melting Alloy Overload Relay 1 HFA001XFTMA HFA001AFTMA HFA001CFTMA HFA001XFSMA 2 HFA002XFTMA HFA002AFTMA HFA002CFTMA HFA002XFSMA 3 HFA003XFTMA HFA003AFTMA HFA003CFTMA HFA003XFSMA 1 6 2492.00 3034.00 3034.00 2176.00 5 HFA005XFTMA HFA005AFTMA HFA005CFTMA HFA005XFSMA 7.5 HFA007XFTMA HFA007AFTMA HFA007CFTMA HFA007XFSMA 10 HFA010XFTMA HFA010AFTMA HFA010CFTMA HFA010XFSMA Full Voltage Non-Reversing (FVNR) Starters With Fusible Switch Disconnect and Solid State Overload Relay (Motor Logic) 1 HFA001XFTSS HFA001AFTSS HFA001CFTSS HFA001XFSSS 2 HFA002XFTSS HFA002AFTSS HFA002CFTSS HFA002XFSSS 3 HFA003XFTSS HFA003AFTSS HFA003CFTSS HFA003XFSSS 1 6 2688.00 3230.00 3230.00 2372.00 5 HFA005XFTSS HFA005AFTSS HFA005CFTSS HFA005XFSSS 7.5 HFA007XFTSS HFA007AFTSS HFA007CFTSS HFA007XFSSS 10 HFA010XFTSS HFA010AFTSS HFA010CFTSS HFA010XFSSS
HFA001AFSMA HFA002AFSMA HFA003AFSMA HFA005AFSMA HFA007AFSMA HFA010AFSMA HFA001AFSSS HFA002AFSSS HFA003AFSSS HFA005AFSSS HFA007AFSSS HFA010AFSSS
2718.00
HFA001CFSMA HFA002CFSMA HFA003CFSMA 2718.00 HFA005CFSMA HFA007CFSMA HFA010CFSMA HFA001CFSSS HFA002CFSSS HFA003CFSSS HFA005CFSSS HFA007CFSSS HFA010CFSSS
2914.00
2914.00
PE4A
Discount Schedule
17-5
17
Model 6 MCC
17
MOTOR CONTROL CENTERS
8998
B- Breaker (Thermal-Mag)
F- Feeder
Amps 15 20 30 40 50 60 70 80 100 125 150 200 250 15 20 30 40 50 60 70 80 100 125 150 200 250
Breaker Frame
Space (IN)
HL 6
JL
HL
12
JL
18
Catalog No. HBF015 HBF020 HBF030 HBF040 HBF050 HBF060 HBF070 HBF080 HBF100 HBF125 HBF150 HBF200 HBF250 SBF015 SBF020 SBF030 SBF040 SBF050 SBF060 SBF070 SBF080 SBF100 SBF125 SBF150 SBF200 SBF250
2300.00
2200.00
Table 17.9:
First Position 8998 Class 8998
a b
Amps Fuse Clips Space (IN) 30 6 60 Class J (Compac 6) 100 30 60 12 Class R 100 200 24 Class R except Compac 6, fuses not included. Not available with Compac 6.
17-6
PE4A
Discount Schedule
Table of Contents
Section 18
TeSys IEC Contactors and Starters
New!
Contactors
TeSys D TeSys D Reversing TeSys F TeSys K TeSys D and F Accessories TeSys K Accessories 18-4 18-6 18-5 18-24 18-8 18-27
18-34
Overload Relays
TeSys D TeSys F TeSys D and F Accessories TeSys K TeSys K Accessories TeSys T
GV7 Manual Motor Starters and Protectors (p. 18-35)
Wiring Systems
GV-Line Bus Bars TeSys D Quickfit AK5 18-37 18-38 18-39
GV3P (p.18-33)
Dimensions
GV2P21 (p.18-33)
18-40
For more information on lighting, definite purpose (DP), and elevator ratings for TeSys D and TeSys F contactors, please refer to catalog 8502CT9901. For more information on machine safety applications using TeSys D and TeSys F, please refer to catalog MKTED208051EN-US. See our website, www.schneider-electric.us, for UL 508A short circuit ratings (SCCR).
18-1
18
3 Pole Contactors
LC
Full Voltage, Non-Reversing Full Voltage, Reversing TeSys D 3 Pole Contactors 9A to 150A Contactor AC-3 Full Load Amps (FLA) 9A FLA 12A FLA 18A FLA 25A FLA 32A FLA 38A FLA (not marketed in US) 40A FLA 50A FLA 65A FLA 80A FLA 95A FLA (not marketed in US) 115A FLA 150A FLA
_____ 1 2
_____
_____
_____
_____
09 12 18 25 32 38 40 50 65 80 95 115 150 A Blank Blank 3 6 9 DC Coils low consumption available for 9 to 38 amp only 5V AL 12V JL 21V ZL 24V BL 48V EL 72V SL 96V DL 110V FL 220V ML 250V UL
18
IEC CONTACTORS AND STARTERS
s t
Everlink Power Connection (40A to 65A only) No Everlink Power Connection (9A to 32A, 80A to 150A) Termination Options (choose one) Screw Termination Spring Terminations s Ring Tongue Terminations t Slip-on Terminations (9A to 12A only) Coil Voltage (choose one) AC Coils (50/60 Hz) 12V 21V 24V 36V 42V 48V 60V 100V 110V 115V 120V 127V 200V 208V 220V 230V 240V 277V 380V 400V 415V 440V 480V 500V 575V 600V 660V J7 Z7 B7 C7 D7 E7 EE7 K7 F7 FE7 G7 FC7 L7 LE7 M7 P7 U7 W7 Q7 V7 N7 R7 T7 S7 SC7 X7 Y5 (50 Hz only)
DC Coils (standard) 12V 21V 24V 36V 48V 60V 72V 110V 125V 220V 250V 440V JD ZD BD CD ED ND SD FD GD MD UD RD
On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power terminations). No price adder for this modification. On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification.
18-2
LC
Full Voltage, Non-Reversing Full Voltage, Reversing TeSys F 2, 3, and 4 Pole Contactors 115A to 800A Contactor AC-3 Full Load Amps (FLA) 115A FLA 150A FLA 185A FLA 225A FLA 265A FLA 330A FLA 400A FLA 500A FLA 630A FLA 780A FLA 800A FLA Number of Poles
_____ 1 2
_____
_____
_____
_____
115 150 185 225 265 330 400 500 630 780 800 2 4 Blank
2 Poles (400A, 500A, and 630A only) 3 Poles (all sizes) 4 Poles (all sizes except 800A) Termination Options - Purchase Lugs Separately
Coil Voltage (choose one and note contactor size it can be used on) AC Coils 24V (50 Hz) 24V (60 Hz) 24V (40-400 Hz) 42V (50 Hz) 48V (50 Hz) 48V (60 Hz) 48V (40-400 Hz) 110V (50 Hz) 110V (60 Hz) 110V (40-400 Hz) 115V (50 Hz) 115V (40-400 Hz) 120V (60 Hz) 120V (40-400 Hz) 120V (40-400 Hz) 127V (60 Hz) 127V (40-400 Hz) 200/208V (60 Hz) 200/208V (40-400 Hz) 208V (40-400 Hz) 220V (50 Hz) 220V (60 Hz) 220V (40-400 Hz) 230V (50 Hz) 230V (40-400 Hz) 240V (50 Hz) 240V (60 Hz) 240V (40-400 Hz) 277V (50 Hz) 277V (40-400 Hz) 380V (50 Hz) 380V (60 Hz) 380V (40-400 Hz) 400V (50 Hz) 400V (40-400 Hz) 415V (50 Hz) 415V (40-400 Hz) 440V (50 Hz) 440V (40-400 Hz) 460/480V (60 Hz) 480V (40-400 Hz) 500V (50 Hz) 500V (40-400 Hz) 600V (40-400 Hz) 660V (60 Hz) B5 B6 B7 D5 E5 E6 E7 F5 F6 B7 FE5 FE7 G6 G7 F7 G6 G7 L6 L7 L7 M5 M6 M7 P5 P7 U5 U6 U7 W5 W7 Q5 Q6 Q7 V5 V7 N5 N7 R5 R7 Q6 N7 S5 S7 X7 Y6 For use on: LC1F115 - F225 LC1F115 - F225 LC1F225 - F400 LC1F115 - F225 LC1F115 - F225 LC1F115 - F225 LC1F115 - F630 LC1F115 - F225 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F400 LC1F500 - F780 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F265 - F780 LC1F115 - F225 LC1F115 - F225 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F800 LC1F115 - F225 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F800 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F115 - F780 LC1F115 - F225 LC1F780 LC1F115 - F225 LC1F115 - F780 LC1F500 - F630 LC1F115 - F225 DC Coils 24V 48V 110V 110V 125V 220V 220/240V 250V 380/400V 440V BD ED FD FW GD MD MW UD QW RD For use on: LC1F115 - F400 LC1F115 - F630 LC1F115 - F780 LC1F800 LC1F115 - F780 LC1F265 - F780 LC1F800 LC1F115 - F780 LC1F800 LC1F115 - F780
18-3
18
Blank
TeSys D Non-reversing
Refer to Catalog 8502CT9901
www.schneider-electric.us
LC1D09
LC1D093
LC1D40A
$ Price Catalog Number a Inductive Resistive AC3 AC1 N.O. N.C. N.O. N.C. 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes AC Coils DC Coils 94.00 119.00 0.5 1 2 2 5 7.5 9 3 LC1D09 cde 0 4 LC1DT20 c 94.00 119.00 20 1 1 2 2 LC1D098 c 94.00 119.00 119.00 149.00 1 2 3 3 7.5 10 12 3 LC1D12 cde 0 4 LC1DT25 c 25 1 1 119.00 149.00 119.00 149.00 2 2 LC1D128 c 1 3 5 5 10 15 18 3 LC1D18 cd 136.00 160.00 0 32 1 1 4 LC1DT32 c 149.00 183.00 149.00 183.00 2 2 LC1D188 c 2 3 7.5 7.5 15 20 25 3 LC1D25 cd 151.00 181.00 0 40 1 1 4 LC1DT40 c 193.00 240.00 193.00 240.00 2 2 LC1D258 c 2 5 10 10 20 30 32 50 3 0 1 1 LC1D32 cd 172.00 213.00 3 5 10 10 30 30 40 3 1 1 LC1D40A 218.00 275.00 60 0 4 0 0 LC1DT60A 296.00 353.00 3 7.5 15 15 40 40 50 3 LC1D50A 234.00 291.00 0 1 1 5 10 20 20 40 50 65 80 3 LC1D65A 322.00 379.00 4 0 0 0 LC1DT80A 446.00 503.00 7.5 15 25 30 60 60 80 3 1 1 LC1D80 363.00 420.00 0 125 4 LC1D80004 b 489.00 524.00 0 0 489.00 524.00 2 2 LC1D80008 b 30 40 75 100 115 3 LC1D115 479.00 479.00 1 1 40 50 100 125 150 200 3 0 LC1D150 696.00 696.00 4 0 0 LC1D115004 630.00 630.00 a Complete catalog number with coil voltage code from table on page 18-6; example, LC1D09G7. b For DC version of these devices replace the 'C' with 'P' (ex. LC1D80004** becomes LP1D80004**). This applies only to 80A 4 pole devices. c On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification. d On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power terminations). No price adder for this modification. e On LC1D09 and LC1D12 only, for slip-on connector versions add "9" to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D099G7). No price adder for this modification. Single Phase Three Phase
No of Poles
18
IEC CONTACTORS AND STARTERS
Table 18.2:
Current Setting Range Amperes
LC1D115
LRD22
Class 10 with Class 10 without Single Phase Single Phase Sensitivity Sensitivity 0.100.16 LRD01 LR3D01 0.160.25 LRD02 LR3D02 0.250.40 LRD03 LR3D03 0.400.63 LRD04 LR3D04 0.631 D09D32 LRD05 LR3D05 11.6 LRD06 LR3D06 1.62.5 LRD07 LR3D07 2.54 LRD08 LR3D08 46 LRD10 LR3D10 5.58 D09D32 LRD12 LR3D12 710 D09D32 LRD14 LR3D14 913 D12D32 LRD16 LR3D16 1218 D18D32 LRD21 LR3D21 1624 D25D32 LRD22 LR3D22 1725 D25D32 2332 D25D32 LRD32 LR3D32 2328 D25D32 2532 D25D32 3038 D32 LRD35 LR3D35 9-13 D40A-D65A f LRD313 LR3D313 12-18 D40A-D65A f LRD318 LR3D318 16-25 D40A-D65A f LRD325 LR3D325 23-32 D40A-D65A f LRD332 LR3D332 30-40 D40A-D65A f LRD340 LR3D340 37-50 D40A-D65A f LRD350 LR3D350 48-65 D40A-D65A f LRD365 LR3D365 17-25 D40-D80 g LRD3322 LR3D3322 23-32 D40-D80 g LRD3353 LR3D3353 30-40 D40-D80 g LRD3355 LR3D3355 37-50 D50-D80 g LRD3357 LR3D3357 48-65 D50-D80 g LRD3359 LR3D3359 5570 D65D80 LRD3361 LR3D3361 6380 D65D80 LRD3363 LR3D3363 80104 D80 LRD3365 80104 D115D150 LRD4365 95120 D115D150 LRD4367 110140 D150 LRD4369 f Overload relays with Everlink termination - direct mount to D40A to D65A only. g Direct mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only. TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91
...
Class 20 with Single Phase Sensitivity LRD1508 LRD1510 LRD1512 LRD1514 LRD1516 LRD1521 LRD1522 LRD1530 LRD1532 LRD313L LRD318L LRD325L LRD332L LRD340L LRD350L LRD365L LR2D3522 LR2D3553 LR2D3555 LR2D3557 LR2D3559 LR2D3561 LR2D3563
Class 20 without Single Phase Sensitivity LR3D1508A1 LR3D1510A1 LR3D1512A1 LR3D1514A1 LR3D1516A1 LR3D1521A1 LR3D1522A1 LR3D1530A1 LR3D1532A1 LR3D3522 LR3D3553 LR3D3555 LR3D3557 LR3D3559 LR3D3561 LR3D3563
$ Price
60.00
62.00
73.00
107.00
107.00
127.00
362.00
18-4
I12
Discount Schedule
TeSys F Non-reversing
Refer to Catalog 8502CT9901
Table 18.3:
Table 18.4:
Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 200 V 208 V HP 30 220 V 240 V HP 40 460 V 480 V HP 75 575 V 600 V HP 100
LC1F115
3 LC1F115 479.00 4 LC1F1154 630.00 3 LC1F150 696.00 40 50 100 125 150 250 4 LC1F1504 825.00 3 LC1F185 938.00 50 60 125 150 185 275 4 LC1F1854 1439.00 3 LC1F225 1059.00 Current Rated 225 315 4 LC1F2254 1935.00 3 LC1F265 1179.00 60 75 150 175 265 350 4 LC1F2654 1646.00 3 LC1F330 1621.00 75 100 200 250 330 400 4 LC1F3304 1846.00 2 LC1F4002 1521.00 100 125 250 300 400 500 3 LC1F400 1874.00 4 LC1F4004 2133.00 2 LC1F5002 4324.00 150 200 400 500 500 700 3 LC1F500 4970.00 4 LC1F5004 5617.00 2 LC1F6302 5917.00 250 300 600 800 630 1000 3 LC1F630 6474.00 4 LC1F6304 7582.00 3 LC1F780 7788.00 Current Rated 780 1600 4 LC1F7804 9940.00 450 800 900 800 1000 3 LC1F800 6676.00 a Complete part number by adding coil voltage code from table below. For example: LC1F115G7. All contactors (except F780) include 1 N.O. coil interlock contact.
b c d
Class 10 Trip c Class 20 c $ Price Catalog Number Catalog Number 3050 F115F185 LR9F5357 LR9F5557 298.00 4880 F115F185 LR9F5363 LR9F5563 298.00 60100 F115F185 LR9F5367 LR9F5567 298.00 90150 F115F185 LR9F5369 LR9F5569 298.00 132220 F185 d F265 LR9F5371 LR9F5571 298.00 200330 F265F500 LR9F7375b LR9F7575b 333.00 300500 F265F500 LR9F7379b LR9F7579b 737.00 380630 F400F630 LR9F7381b LR9F7581b 905.00 When mounting overload relays LR9F557 to LR9F571 directly beneath the contactor, supporting the relays with a mounting plate is recommended. With overload relays LR9F775 to LR9F781, use of a support mounting plate is mandatory. IEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current: Class 10 between 4 and 10 seconds Class 20 between 6 and 20 seconds Interconnection kit LA7F407 is required to mount an LR9F71 to an LC1F185. For Direct Mounting to Contactor LC1
Table 18.6:
Contactor D09D150 LC1D80LC1D150 only F115, F150, and F185 F265, and F330 F400 F780
e f g h i
D09-D32, DT20-D258 BL EL FL ML UL Low Consumption D09D150 BD ED FD GD MD UD RD F115-F330 BD ED FD GD MD UD RD F400F780 ED FD GD MD UD RD Not available for LC1D80 - LC1D150 Not available for LC1D115 or LC1D150 Not available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits. For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901. For use with F265F330 only.
Table 18.7:
Volts AC/DC 50/60 HZ
Coil Voltage Codes for AC and DC Voltages for F800 (includes built-in surge suppressor)
24 48 110 FW 120 FW 127 FW 208 220 MW 240 MW 277 380 QW 415 QW 440 QW 480 575 600 660
TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-11 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49
I12
Discount Schedule
18-5
18
Table 18.5:
Contactors
Each 3-pole device is pre-wired with line and load side power wiring for reversing applications. Each 4-pole device is pre-wired with load side power wiring Table 18.8:
Single Phase
LC2D09
Maximum Current Built In Auxiliary $ Price No. of N.O. Catalog Contacts Inductive Resistive Power Number (per contactor) AC DC AC3 AC1 Poles ab Control Control 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes N.O. N.C. 0.5 1 2 2 5 7.5 9 3 1 1 LC2D09c 234.00 317.00 20 4 1 1 LC2DT20 234.00 317.00 1 2 3 3 7.5 10 12 3 1 1 LC2D12c 317.00 368.00 25 4 1 1 LC2DT25 317.00 368.00 1 3 5 5 10 15 18 35 3 1 1 LC2D18c 344.00 400.00 32 4 1 1 LC2DT32 419.00 443.00 2 3 7.5 7.5 15 20 25 3 1 1 LC2D25c 374.00 436.00 40 4 1 1 LC2DT40 456.00 477.00 2 5 10 10 20 30 32 50 3 1 1 LC2D32c 415.00 503.00 3 5 10 10 30 30 40 60 3 1 1 LC2D40A 565.00 650.00 3 7.5 15 15 40 40 50 70 3 1 1 LC2D50A 596.00 680.00 5 10 20 20 50 50 65 80 3 1 1 LC2D65A 778.00 857.00 7.5 15 30 30 60 60 80 3 1 1 d 125 4 d 30 40 75 100 115 3 1 1 LC2D115 e 1165.00 1165.00 200 4 LC2D115004 e 1391.00 1391.00 40 50 100 125 150 200 3 1 1 LC2D150e 1598.00 1598.00 a Use voltage codes from the Voltage Codes table below to complete the catalog number. For example: LC2D09G7 b Includes mechanical interlock without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LAD8N auxiliary contact block. c For LC2D09LC2D32, electrical interlock can be included by adding a V to the end of the catalog number (ex: LC2DO9B7V). List price adder: $5.00. d For these items, order two non-reversing contactors and one mechanical interlock separately. See page 18-4 and 18-14 for selection. e Includes mechanical interlock (Type LA9D11502) with pre-wired electrical contacts for interlocking contactor operating coils.
18
IEC CONTACTORS AND STARTERS E164862 CCN NLDX LR43364 Class 3211 04
Table 18.9:
Contactor D09D150
LC1D80LC1D150
D09-D32, DT20-D258 BL EL FL ML UL Low Consumption D09D150 BD ED FD GD MD UD RD F115F330 BD ED FD GD MD UD RD F400F780 ED FD GD MD UD RD f Not available for LC1D80 - LC1D150. g Not available for LC1D115 or LC1D150. h Not available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits. i For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901. j For use with F265F330 only.
Table 18.10:
Volts AC/DC 50/60 Hz 24
Coil Voltage Codes for AC and DC Coil Voltages for F800 (includes built-in surge suppressor)
48 110 FW 120 FW 127 FW 208 220 MW 240 MW 277 380 QW 415 QW 440 QW 480 575 600 660
TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
18-6
I12
Discount Schedule
Contactors
www.schneider-electric.us
HOW TO ORDER:
Components are available for customer assembly of TeSys F reversing contactors. For example, the following components must be ordered to build a 75 hp @ 460 V reversing contactor with a 120 V/60 Hz coil: Table 18.11:
Quantity 2 6 2 1 1 Catalog Number LC1F115G6 DZ2FF1 LADN11 LA9FF976 LA9FF970 Description Contactors Lugs (page 18-12) Auxiliary contacts Power connections Mechanical interlock
LC1F265
Table 18.12:
3-Pole Contactors
Maximum Current Inductive AC3 Amperes Resistive AC1 Amperes Holding Circuit Contact Built Into Coil
Table 18.13:
For use with
Table 18.14:
LC1F115 LA9FF976 LC1F150 LA9F15076 LC1F185 LA9FG976 LC1F265 LA9FH976 LC1F330 LA9FJ976 LC1F400 LA9FJ976 LC1F500 LA9FK976 LC1F630, F800 LA9FL976 For two contactors of different size, refer to pages 18-15.
TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-11 TeSys F overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-42
I12
Discount Schedule
18-7
18
Catalog $ Price Numbera 230 V 460 V 575 V N.O. N.C. hp hp hp 40 75 100 115 200 1 0 LC1F115 479.00 50 100 125 150 250 1 0 LC1F150 696.00 60 125 150 185 275 1 0 LC1F185 938.00 75 150 200 265 350 1 0 LC1F265 1179.00 100 200 250 330 400 1 0 LC1F330 1621.00 125 250 300 400 500 1 0 LC1F400 1874.00 200 400 500 500 700 1 0 LC1F500 4970.00 300 600 800 630 1000 1 0 LC1F630 6872.00 Current rated 780 1600 0 0 LC1F780 7788.00 450 800 900 800 1000 0 0 LC1F800 6676.00 a Use coil voltage codes from the Voltage Codes table on page 18-6 to complete the contactor catalog number. 200 V hp 30 40 50 60 75 100 150 250
Contactor Accessories
Table 18.15:
Snap-On Mounting
4a
2 To front of LC D80 and D115 or To left side of LCF To side of LCD09 to D150 only (not for use on TeSys F)
1 1 LAD8N11 e 20.70 2 0 LAD8N20 e 20.70 For low consumption coils (LC1D09 to D32 only), only one front-mounted two-contact block allowed. No sidemounted contact blocks allowed. For spring terminal versions of these blocks, add a 3 to the end of the catalog number. (Ex. LADN223). No price adder for this modification. Including 1 N.O. + 1 N.C. make before break overlapping contacts. This block cannot be added to the LC1D 09 to D32 contactors; a maximum of 2 blocks can be mounted on the LC1D40A to LC1/LP1D80 contactors only. 1 block may be added to the left side of the LC1D 09 to D32, AC coils only; 1 block may be added to each side of the LC1D 40A to D80 contactors, AC coils only. Cannot be installed on TeSys D contactors with DC coils.
18
IEC CONTACTORS AND STARTERS E164862 CCN NLDX LR43364 Class 3211 04
Table 18.16:
N.O. To front of LP D40D80, LC DT20D258 (4P), 2 LC D09 to D80 1 or To right side of LC F f Device supplied with 4 ground terminal points.
Snap-On Mounting
Table 18.17:
Snap-On Mounting To front of LP D40D80, LC DT20D258 (4P), LC D09 to D150 or To right side of LC F g h i
0.1 to 3 sg LADT0 131.00 0.1 to 30 s LADT2 131.00 10 to 180 s LADT4 131.00 1 to 30 si LADS2 131.00 0.1 to 3 sg LADR0 131.00 On de-energization 0.1 to 30 s 1 1 LADR2 131.00 (off-delay) 10 to 180 s LADR4 131.00 Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. For spring terminal versions of these blocks, add a 3 to the end of the catalog number. (Ex. LADT23). No price adder for this modification. With switching time of 40 ms 15 ms between the opening of the N.C. contact to the closing of the N.O. contact. 1 1
Table 18.18:
For silent operation and energy LAD6K10jk conservation For silent operation and energy LC1 D80 to D150 LP1 D80 LA6DK20jk conservation j Does not include internal coil clearing contact. k Complete catalog number by adding coil voltage code. For example: LAD6K10F.
77.00 77.00
Table 18.19:
Volts AC or DC
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
18-8
I12
Discount Schedule
Contactor Accessories
www.schneider-electric.us
RC Coil Suppressor
Limitation of transient voltage to 300% of nominal voltage maximum Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times normal)
Table 18.20:
Installed by
LA4DA1U
Snap-on mounting and connection without tools to the contactor coil terminals
LA4DA2U
Limitation of transient voltage value to 200% of nominal voltage maximum Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times normal)
Table 18.21:
Installed by
Operating voltage 50/60 Hz 2448 V 50127 V Snapping into cavity on right side without toolsb 110250 V LC1D40A to LC1D65A (3P), 24-48 V Snap-on mounting and connection without tools to the LC1DT60A to LC1DT80A 50-127 V contactor coil terminals (4P) 110-250 V 2448 Vac LCD80 to D115 (3P or 4P) Screw connection to the contactor coil terminals 50127 Vac LCD12, D25 (4P) 110250 Vac 2448 Vdc Screw connection to the contactor coil terminals LCD80 (3P or 4P) 50127 Vdc 110250 Vdc a For DC coils 3-pole contactors are fitted with built-in surge suppression as standard.
No overvoltage or oscillating frequency Polarized component. Increased drop-out time (6 to 10 times normal)
Table 18.22:
Installed on the upper part by Snap-on mounting and connection w/o tools to the contactor coil terminals Clip-on front mounting
LA4DC3U
Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks
Table 18.23:
Operating Voltage 50/60 Hz and DC Catalog Number $ Price 24 (AC only) LAD4TB 26.20 Snapping into cavity on right side of contactor b 72 (AC only) LAD4TS 26.20 12 - 24 V LAD4T3B 26.20 25 - 72 V LAD4T3S 26.20 LC1D40A to LC1D65A (3P), Clip-on front mounting and connection without tools LC1DT60A to LC1DT80A 73 - 125 V LAD4T3G 26.20 to the contactor coil terminals c (4P) 126 - 250 V LAD4T3U 26.20 251 - 440 V LAD4T3R 26.20 24 (AC only) LA4DB2B 56.00 72 (AC only) LA4DB2S 26.20 Screw Mounting d LCD80 24 (DC only) LA4DB3B 56.00 72 (DC only) LA4DB3S 56.00 b Installing suppressor into the cavity makes the electrical connection. Overall width of contactor remains the same. c For LCD09 through LCD65A with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as standard. d Mounting at the top of the contactor on coil terminals A1 and A2.
Table 18.24:
Cabling Accessories
Usage Mounting on LC1D09 to D38 LC1DT20 to DT60 AC only Operating voltage 50/60 Hz Without coil suppression 24-48 V With coil suppression 50-127 V (varistor) 110-250 V Catalog Number LAD4BB LAD4BBVE LAD4BBVG LAD4BBVU LAD4BB3 $ Price 23.00 23.00 23.00 23.00 26.20
For adapting existing wiring to a new product or for use with top mount accessory.
For adapting existing wiring to a new product or for use with LC1D40A to LC1D65A top mount accessory (with no coil suppressor)
LAD4BB
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
I12
Discount Schedule
18-9
18
Contactor Accessories
The following accessories require use of cabling accessories (LAD4BB) for proper mounting. See page 18-9 for illustration.
On-delay a
0.12 s LA4DT0U 1.530 s LA4DT2U 25500 s LA4DT4U For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; ZD for DC.
Interface Modules b
These modules allow the contactor coils to be energized from low voltage and low current level signals. They come in mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manually turning the contactor on and off. When a module receives a low level signal, it allows the separate sourced control voltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays. Table 18.26:
24250 Vac LC1D09D150 Relay LC1D09D150 Relay Plus LC1D09D150 Manual Operation LC1D09D150 Solid State LC1D09D65 Adapter required for D09 - D65A, see table 18.24. Interface Type Operational Voltage 100250 Vac Input Voltage 24 Vdc 48 Vdc 24 Vdc 48 Vdc 24 Vdc Catalog Number LA4DFB LA4DFE LA4DLB LA4DLE LA4DWB $ Price 55. 55. 71. 71. 71.
18
IEC CONTACTORS AND STARTERS LA4DFB
b
LC1D80D115
LC1DB7 CADB7 LADLVRT24V c 124. CADG7 LADLVRT120V c 124. LC1DG7 CADLE7 LADLVRT208V c 124. LC1DLE7 Top mount bracket (required when using above modules) D09 - D32 LAD4BB c 23. Top mount bracket (required when using above modules) D40 - D65 LAD4BB3 c 23. Fuse LA9D941 120. c LAD4BB must be used when the low voltage ride through module is being used with contactors 32 A and less, and TeSys CAD Series of Control Relays. The LAD4BB3 must be used with the D40 - D65A. See table 18.24 on page 18-10. TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
LADLVRT
E1
E2
LADLVRT
A2
E1 E2
1.25 32
A1 A2
A1
A2
1.85 47
A1
LAD4BB
Contactors 40 A80 A
18-10
I12
Discount Schedule
Contactor Accessories
www.schneider-electric.us
Table 18.29:
LA9D1260
2 poles
LA9D2561
4 poles Second coil connection Control circuit take-off from main pole Spreaders for increasing pole pitch to 45 mm
Table 18.30:
For Marking
Description For use with contactors LC1/LP1 4-pole contactors D80 - D115 D09-D65A, DT20-DT80A, LADN, LADT, LADR For holder LA9D92 Sold in lots of 100 100 1 Catalog Number LA9D92 LAD90 LA9D93 $ Price each .06 .06 4.30
LA9D40961
Reference label holder snap-on 8 x 22 mm Reference label holder snap-on 8 x 18 mm 3 poles Sheet of 300 labels self adhesive 7 x 21 mm
Description Set of shims for mounting LAD8N and LA8DN Retrofit plate for replacement of LC1D40-D65 with LC1D40A-D65A 35 mm DIN Rail 2 meters long
Sold in lots of 1 1 10
Table 18.32:
LA9D6567
Three-pole Four-pole
Replacement contacts
For use with contactors LC1D115 LC1D150 LC1D115 Catalog Number LA5D1158031 LA5D150803 LA5D115804 $ Price 239.00 239.00 318.00
Table 18.33:
Arc chambers
For use with contactors LC1D115 LC1D150 LC1D115 Catalog Number LA5D11550 LA5D15050 LA5D115450 $ Price 90.00 90.00 119.00
Three-pole Four-pole
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
LA9D511
I12
Discount Schedule
18-11
18
Table 18.31:
For Mounting
Contactor Accessories
TeSys F Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.34:
LA9D09981
Description
Suppressor Blocks
$ Price 21.80 20.70 5.50
Operating limit: up to 220 V, 50/60 Hz coils For Use Catalog Number With coils LX1FF, FG, FH, F115, F150, F185, F225, F265, F330 LA9F980 With coils LX1FJ, FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F150, F185, F225, LA9D09980 F265, F330 Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block LA9D09981
Table 18.35:
LA9F980
Kit Catalog Cable Size AWG Contactor LugNumber Type LC1 Contactor Only range
14 to 2/0 6 to 3/0 6 to 300 MCM 4 to 500 MCM 2 x 2 to 600 MCM 3 x 2 to 600 MCM
LR9F557 to F569 LR9F557 to F571 LR9F571 LR9F775 to F779 LR9F775 to F781 LR9F775 to F781 LR9F781
F115 F150 to F185 F225, F265 F265 or F330 F400 F500 F630
18
IEC CONTACTORS AND STARTERS LA9F70
F630, F800
F780 DZ2FX6 4 x 1/0 to 750 MCM a Lug kits ending in the number 6 include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor will require a different size lug for your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws, washers, and nuts) are provided with the contactors and overload relays, not with the lugs. See Table 18.37 for pricing.
Table 18.36:
b c
F115 DZ2FF1 14 to 2/0 F150, F185 DZ2FG1 6 to 3/0 F225, F265, F330 DZ2FH1 6 to 300 MCM F400 DZ2FJ1 4 to 500 MCM F500 DZ2FK1 2 X 2 to 600 MCM F630 DZ2FLb 3 X 2 to 600 MCM F780 DZ2FX1 4 X 1/0 to 750 MCM For 2-pole F630 contactors, order 2 DZ2FL1 (L1 and T2), and 2 DZ2FL3 (L2 and T1). For 4-pole F6304, order 2 DZ2FL1 (L1 and T4), 4 DZ2FL2 (L2, T2, L3, T3) and 2 DZ2FL3 (L4 and T1). Lugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one (1) lug. Mounting hardware (screws, washers, nuts) are provided with the contactors, not the lugs. See Table 18.37 for pricing.
Table 18.37:
Lugs Pricing
$ Price 39.30 65.00 65.00 65.00 131.00 164.00 163.80 6.50 11.00 Lug Catalog Number DZ2FH1 DZ2FJ1 DZ2FK1 DZ2FL1 DZ2FL2 DZ2FL3 DZ2FR1 DZ2FX1 $ Price 11.00 11.00 21.80 27.30 55.00 27.30 173.30 27.30
Lug Catalog Number DZ2FF6 DZ2FG6 DZ2FH6 DZ2FJ6 DZ2FK6 DZ2FL6 DZ2FX6 DZ2FF1 DZ2FG1
These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits. Table 18.38: Power Terminal Protection Shrouds
For Use With 2-, 3-, And 4-pole Contactors LC1F115 LC1F150, F185 LC1F225, F265, F330, F400 and F4002, F500 and F5002 LC1F630, F6302 and F800 LC1F1154 LC1F1504 and F1854 LC1F2254, F2654, F3304, F4004, F5004 LC1F6304 Number of Shrouds Per Set 6 6 6 6 8 8 8 8 Catalog Number LA9F701 LA9F702 LA9F703 LA9F704 LA9F706 LA9F707 LA9F708 LA9F709 $ Price 42.40 61.00 82.00 93.00 58.00 80.00 111.00 120.00
For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used in place of lugs for power connections. Table 18.39: Insulated Terminal Blocks
For overload relay LR9 F557, F563, F567, F569 Maximum Cable Size 300 MCM Catalog Number LA9F103 $ Price 55.00
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47
18-12
I12
Discount Schedule
Replacement Parts
www.schneider-electric.us
Table 18.40:
Two-pole
Three-pole
LA5FG431
Four-pole
Table 18.41:
Arc chambers
$ Price 280. 305. 431. 90. 101. 179. 269. 287. 305. 341. 646. 431. 750. 119. 131. 248. 299. 414. 573. 610. 861. 431.
LA5F11550
a b c d
For use on contactors Catalog Number LC1F4002 2 poles LA5F400250 Two-pole LC1F5002 2 poles LA5F500250 LC1F6302 2 poles LA5F630250 LC1F115 3 poles LA5F11550 LC1F150 3 poles LA5F15050 LC1F185 3 poles LA5F18550 LC1F265 3 poles LA5F26550 LC1F330 3 poles LA5F33050 Three-pole LC1F400 3 poles LA5F40050 LC1F500 3 poles LA5F50050 LC1F630 3 poles LA5F63050 LC1F780 1 pole LA5F780150d LC1F800 3 poles LA5F80050 LC1F1154 4 poles LA5F115450 LC1F1504 4 poles LA5F150450 LC1F1854 4 poles LA5F185450 LC1F2654 4 poles LA5F265450 Four-pole LC1F3304 4 poles LA5F330450 LC1F4004 4 poles LA5F400450c LC1F5004 4 poles LA5F500450c LC1F6304 4 poles LA5F630450b LC1F7804 1 pole LA5F780150d Supplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers. Comprises single-pole components. Comprises 2-pole components. 2 identical components per pole are supplied.
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47
I12
Discount Schedule
18-13
18
Contactors Accessories
Table 18.42:
Contactors
Mechanical interlock Without electrical interlock With incorporated electrical interlock (2 N.C. contacts)
Set of power connections Reversing contactors for motor control Four pole contactors
Catalog Number LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 LC1DT20, LC1DT25, LC1DT32, LC1DT40 LAD9R1e
$ Price 32.10
$ Price
LADT9R1e 36.90 LADT9R1Ve 45.50 e Kit including mechanical interlock and wiring.
18
IEC CONTACTORS AND STARTERS
LC1D40, LC1D50, LC1D/LP1D65 LC1D40A, D50A, D65A LA9D50978 LAD4CM 31.70 45.00 LA9D4002 Not Available 45.90 LA9D6569 LA9D65A69 53.00 75.00 LA9D6570 Not Available 63.00 LC1D80 AC coil LC1D80 DC coil LA9D50978 LA9D80978 31.70 31.70 LA9D4002 LA9D8002 45.90 65.00 LA9D8069 LA9D8069 65.00 65.00 LA9D8070 LA9D8070 79.00 79.00 LC1D115 and LC1D150 Not Available LA9D11502 78.00 LA9D11569 129.00 LA9D11571 (3P) LA9D11570 (4P) (D115 only) 53.00 53.00 TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
18-14
I12
Discount Schedule
Contactors Accessories
www.schneider-electric.us
Table 18.43:
With 2 Identical Contactors a
LA9F970
LA9F976
Horizontal Mounting LC1F115 LC1F150 LC1F185 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 or F800 Vertical Mounting LC1F115 or F150 LC1F185 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 or F800 LC1F780
LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 LA9FF4F LA9FG4G LA9FH4H LA9FJ4J LA9FJ4J LA9FK4K LA9FL4L LA9FX970 b
53.00 53.00 53.00 76.00 76.00 76.00 76.00 76.00 97.00 113.00 126.00 149.00 149.00 149.00 149.00 508.00
LA9F977
Horizontal Mounting LC1F115/4 LC1F150/4 LC1F185/4 LC1F265/4 LC1F330/4 LC1F400/4 LC1F500/4 LC1F630/4 Vertical Mounting LC1F115/4 LC1F185/4 LC1F265/4 LC1F330/4 LC1F400/4 LC1F500/4 LC1F630/4 LC1F780/4
Set of Power Connections Three-Pole LA9FF982 LA9F15082 LA9FG982 LA9FH982 LA9FJ982 LA9FJ982 LA9FK982 LA9FL982 d d d d d d d b Four-Pole LA9FF977 LA9F15077 LA9FG977 LA9FH977 LA9FJ977 LA9FJ977 LA9FK977 LA9FL977 d d d d d d d c $ Price 53.00 53.00 53.00 83.00 113.00 113.00 154.00 233.00
Mechanical Interlock Kit Catalog Number LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 LA9FF4F LA9FG4G LA9FH4H LA9FJ4J LA9FJ4J LA9FK4K LA9FL4L LA9FX970 c
$ Price 53.00 53.00 53.00 76.00 76.00 76.00 76.00 76.00 97.00 113.00 149.00 149.00 149.00 149.00 149.00 508.00
LA9F4
Table 18.45:
Upper Contactor LC1F185 or 1854 LC1F265 or 2654 LC1F330 or 3304
LA9FX970
L1 A1 1 2 3 4 5 6 1 2 3 4 5 6 L2 L3 A1
A2
A2
LC1F115/150 or 1154/1504 LC1F115/150 or 1154/1504 LC1F185/1854 or 265/265A LC1F115/150 or 1154/1504 LC1F400 or 4004 LC1F185 or 1854 LC1F265/2654 or 330/330A LC1F115/150 or 1154/1504 LC1F185 or 1854 LC1F500 or 5004 LC1F265/2654 or 330/330A LC1F400 or 4004 LC1F115/150 or 1154/1504 LC1F185 or 1854 LC1F630, 6304 or LC1F265/2654 or 330/330A LC1F800 LC1F400 or 4004 LC1F500 or 5004 a With identical or different numbers of poles. b Double mechanical interlock with 2 mechanical links and 3 power connection bars. c Double mechanical interlock with 2 mechanical links and 4 power connection bars. d Power connection to be assembled by the customer, except for contactors LC1F780 and F7804. e Lower contactor must have equal or lower current rating. TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . . . . . . .pages 18-18 to 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-42 to 18-47
A2
L1 L2 L3 N
Transfer/Changeover Applications
I12
Discount Schedule
18-15
18
Table 18.44:
Component parts for the assembly of TeSys F 3-pole or 4-pole transfer contactors
Overload Relays
LA7D901
Table 18.47:
Accessories
Description For use with Standard Packaging 10 10 10 1 1 1 Catalog Number LAD7C1 LAD7C2 LA7D901 LAD703b LA7D03b LAD7305 $ Price 8.70 8.70 2.20 43.70 43.70 100.00
Pre wiring kit allows direct connection of the N.C. contact LC1D09 through D18 of relay LRD01D32 or LR3D01D32 to the contactor LC1D25, D32 All relays except LRD01D32, LR3D01D32 and Stop button locking device LR9D LRD01-D32, LRD3, LR3D01-D32, LR3D3 Remote stop/tripping or electrical resetc All relays except LRD01D32, LR3D01D31 Reset by flexible cable 500 mm (19.6 in.) LRD01-D32, LRD3, LR3D3 b Part number to be completed by adding coil voltage code. For example: LAD703F.
18
IEC CONTACTORS AND STARTERS LA7D03 LA7F90 LA9F70 LA7F701
Table 18.48:
Volts AC 50/60 Hz c d
DC J B E F M The time that the LA7D03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s rest time; maximum pulse duration of 20 s with rest time of 300 s. Consumption on inrush and sealed: < 100 VA Not available for LRD01-D32, LR3D01-D32.
For use with relays LR9F557, F563, F567, F569 and F571 LR9F775, F779 and F781
These clear plastic protective shrouds are an effective means to meet international finger-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits. Table 18.50: Power terminal protection shrouds, single-pole
For use with relays LR9F557 LR9F563, F5 67, F569 LR9F571 LR9F775, F779, F781 Catalog Number LA9F701 LA9F702 LA9F705 LA9F703 $ Price 42.40 61.00 86.00 82.00
Table 18.51:
Table 18.52:
For relays LR9F557, F563, F567, F569 LR9F557, F5 63 LR9F571 LR9F775, F7 79 LR9F781 LR9F775, F779, F781 LR9F781 e Mounting plate required.
Table 18.53:
Marking accessories
Sold in units of: 100 Catalog Number LA7D903 $ Price .03 each
Main overload selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-3 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-45 to 18-47 TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91
18-16
I12
Discount Schedule
Table 18.54:
Table 18.55:
Rated Nominal Voltage 12 21a 24 32 36 42 48 60 100 110 115 120 127 200 208 220/230 230 230/240 277 380/400 400 415 440 480 575 600 690 Specifications Average consumption - Inrush (inductance .75) - Sealed (inductance .3)
oC
For LC1D09, D12, D18For old D2 style contactors where the catalog number includes the auxiliary contact arrangement
Catalog Number 50 Hz LX1D2Z5 LX1D2B5 LX1D2C5 LX1D2D5 LX1D2E5 LX1D2F5 LX1D2G5 LX1D2M5 LX1D2P5 LX1D2U5 LX1D2W5 LX1D2Q5 LX1D2V5 LX1D2N5 LX1D2R5 LX1D2S5 LX1D2Y5 Catalog Number 60 Hz LX1D2Z6 LX1D2B6 LX1D2E6 LX1D2F6 LX1D2G6 LX1D2L6 LX1D2M6 LX1D2U6 LX1D2W6 LX1D2Q6 LX1D2R6 LX1D2T6 LX1D2S6 LX1D2X6 Catalog Number 50/60 Hz LX1D2Z7 LX1D2B7 LX1D2D7 LX1D2E7 LX1D2F7 LX1D2G7 LX1D2M7 LX1D2P7 LX1D2U7 LX1D2Q7 LX1D2V7 LX1D2N7 LX1D2R7 $ Price
26.20
26.20
26.20
26.20
LX1D2
26.20
52.40
26.20
Table 18.56:
For LC1D25, D32For old D2 style contactors where the catalog number includes the auxiliary contact arrangement
Catalog Number 50 Hz LX1D4Z5 LX1D4B5 LX1D4C5 LX1D4D5 LX1D4E5 LX1D4F5 LX1D4G5 LX1D4M5 LX1D4P5 LX1D4U5 LX1D4W5 LX1D4Q5 LX1D4V5 LX1D4N5 LX1D4R5 LX1D4S5 LX1D4Y5 50 Hz Catalog Number 60 Hz LX1D4Z6 LX1D4B6 LX1D4E6 LX1D4F6 LX1D4G6 LX1D4L6 LX1D4M6 LX1D4U6 LX1D4W6 LX1D4Q6 LX1D4R6 LX1D4T6 LX1D4S6 LX1D4X6 60 Hz Catalog Number 50/60 Hz LX1D4Z7 LX1D4B7 LX1D4D7 LX1D4E7 LX1D4F7 LX1D4G7 LX1D4M7 LX1D4P7 LX1D4U7 LX1D4Q7 LX1D4V7 LX1D4N7 LX1D4R7 50/60 Hz $ Price 21b 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660
72.00
72.00
72.00
72.00
72.00
Specifications
90 VA 7.5 VA
100 VA 8.5 VA
100 VA at 50 or 60 Hz 8.5 VA at 50 or 60 Hz
Operating range 80110% of 80110% of 85110% of at < 55oC / 131oF nominal voltage nominal voltage nominal voltage b For use in 24 volt applications involving serial timer modules refer to page 18-10. TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
I12
Discount Schedule
18-17
18
80110% of nominal @ 50 Hz, Operating range@ 60 85110% of nominal @ 60 Hz Voltage for special coils fitted in contactors with serial timer modules, with 24 V supply.
21 b 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Specifications Average 50 Hz 60 Hz consumption Inrush 60 VA 70 VA (inductance .75) Sealed 7 VA 7.5 VA (inductance .3) 80110 % of 80110% of Operating range at < 55oC / 131oF nominal voltage nominal voltage
52.40
Table 18.57:
Rated Nominal Voltage V 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660
Catalog Number 50 Hz LX1D6B5 LX1D6C5 LX1D6D5 LX1D6E5 LX1D6F5 LX1D6G5 LX1D6M5 LX1D6P5 LX1D6U5 LX1D6W5 LX1D6Q5 LX1D6V5 LX1D6N5 LX1D6R5 LX1D6S5 LX1D6Y5
For old style and new TeSys style contactors where the catalog number may or may not include the auxiliary contact arrangement.
Catalog Number 50 Hz LX1D8B5 LX1D8C5 LX1D8D5 LX1D8E5 LX1D8F5 LX1D8FE5 LX1D8FC5 LX1D8M5 LX1D8P5 LX1D8U5 LX1D8Q5 LX1D8V5 LX1D8N5 LX1D8R5 LX1D8S5
18
IEC CONTACTORS AND STARTERS
For old style and new TeSys style contactors where the catalog number may or may not include the auxiliary contact arrangement.
Specification
50 Hz
60 Hz
50/60 Hz
Specification
50 Hz
50/60 Hz
Specification
50 Hz 300 VA 22 VA
60 Hz 300 VA 22 VA
Average consumption: -inrush (inductance .75) 200 VA -sealed (inductance .3) 20 VA Operating range at < 55oC / 131oF
Average consumption: 220 VA 245 VA at 50 or 60 Hz -inrush (inductance .3) 160 VA 22 VA 26 VA at 50 or 60 Hz -sealed (inductance .3) 7.0 VA 85110% of nominal voltage Operating range at < 55oC / 131oF
Average consumption: 140 VA 140 Va (Inductance: .9) -inrush (inductance .3) 7.5 VA 7.5 Va (Inductance: .9) -sealed (inductance .3) 80115% of nominal voltage Operating range at < 55oC / 131oF
Table 18.60:
For LC1F115, F150, F185, F265, F330, F400, F500, F630, F780, F800 LX1 coils are the standard coils that are included when a voltage code is added to the contactor part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX1 and LX9 coils can be used on the previous F-line contactors.
Device Type Hz Catalog Number LX1FF LX1FF LX9FF LX1FG LX1FG LX9FG LX1FH LX9FH LX1FJ LX9FJ f LX1FK LX9FK f LX1FL LX9FL f LX1FX LX4F8 e 24 V 024 020 024 020 0242 910 910 910 48 V 048 040 048 048 040 048 0482 0482 048 917 048 917 048 917 110 V 110 092 110 110 092 110 1102 1102 110 925 110 925 110 924 110 FW 120 V 127 095 127 127 095 127 1272 1272 110 925 110 925 110 925 110 FW 208 V 200 162 200 200 162 200 2002 2002 200 930 200 930 200 930 200 Catalog Number Suffixg 220 V 240 V 277 V 380 V 220 184 220 220 184 220 2202 2202 220 931 220 931 220 930 220 MW 240 187 220 240 187 220 2402 2402 240 932 240 932 240 931 220 MW 264 220 260 264 220 260 2772 2772 280 932 280 932 260 932 280 380 316 380 380 316 380 3802 3802 380 936 380 936 380 935 380 QW 415 V 415 340 415 415 340 415 3802 3802 415 936 415 936 415 936 415 QW 440 V 415 360 415 415 360 415 4402 ... 415 937 415 937 415 936 415 QW 480 V 500 380 500 450 380 500 5002 5002 415 937 415 937 415 937 415 600 V 600 475 600 475 6002 600 600 600 $ Price 78.00 78.00 78.00 108.00 108.00 108.00 138.00 138.00 287.00 287.00 360.00 360.00 398.00 483.00 795.00 725.00
LX1D6
50 F115F150 60 40400 50 F185 60 F225 40400 40400 F265F330 40400 40400 F400d 40400 40400 F500d 40400 40400 F630d 40400 F780, FX c 40400 F800 50/60 c d e f g
LC1F780 contactors operate on 2 coils as a set. The LX1FX part number includes both coils. The 600 V coils for the F400, F500 and F630 do not include an auxiliary contact for holding circuits. If required, select appropriate contacts from page 18-8. Also requires rectifier DR5TE4U for 110 V240 V coils, DR5TE4S for 380 V440 V coils. See table below for pricing. Coil circuit requires a separately mounted rectifier. Order from Rectifier Table. Complete catalog number by adding suffix. For example: LX1FF024.
Table 18.61:
Coil LX9F910 LX9F917 LX9F925 LX9F926 LX9F931 LX9F936 LX9F937 LX9F938
Rectifier Table
Rectifier Catalog Number DR5TF4V DR5TF4V DR5TE4U DR5TE4U DR5TE4U DR5TE4S DR5TE4S DR5TE4S $ Price 75.00 75.00 75.00 75.00 75.00 75.00 75.00 75.00
Select a fast drop-out coil (LX9), or Use a maintained contact Stop button, or Use an interposing relay.
18-18
I12
Discount Schedule
Table 18.62:
Table 18.64:
124.00
124.00
124.00
Average consumption 22 W 23 W Operating range at 80110% 75120% < 55oC /131oF of nominal voltage of nominal voltage
Table 18.65:
Table 18.63:
Specifications Average consumption 11 W 13 W 80110% of nominal 70125% of nominal Operating range at oC / 131oF voltage voltage < 55 a For old style contactors where the catalog number includes the auxiliary contact arrangement (ex. LP1D2510). The new style TeSys DC controlled contactors (ex. LC1D25BD) do not have replaceable coils. b For use in 24 volt applications with serial timer modules. Refer to page 18-10. c No replacement DC coils for TeSys D contactors.
Specifications Average consumption 22 W 23 W Operating range 80110% 70120% oC / 131oF at < 55 nominal voltage nominal voltage d Wide range coils cannot be used with contactors utilizing both front and side mount auxiliaries.
Table 18.66:
Rated Nominal Voltage V 24 48 60 72 110 125 220 250 440 Average consumption Operating range at < 55oC / 131oF
78.00
Note: DC coils for LC1D09-D32, LC1DT20 - LC1DT40, and LCIDttA contactors are not replaceable. Specifications LC1D09-D32, LC1DT20 - LC1DT40 LCIDttA Average consumption Inrush 5.4 w Sealed 5.4 w Inrush 19 w Sealed 7.4 w Low consumption Inrush 2.4 w Sealed 2.4 w Operating range 70 - 125% @ 60oC 75 - 125% @ 60oC
78.00
70 - 125% @ 60oC
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
I12
Discount Schedule
18-19
18
134.00
134.00
134.00
TeSys F DC Coils
Refer to Catalog 8502CT9901
www.schneider-electric.us
LX4 coils are the standard coils when a voltage code is added to the part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX4 and LX9 coils can be used on previous F-line devices. Table 18.67:
Device Type F115, F150 F185, F225 F265, F330
LX4 coils for LC1F115, F150, F185, F265, F400, F500, F630, F780, F800
Catalog Number
Catalog Number Suffix 110 V 125 V 220 V 220 220 220 220 932 220 932 220 932 220 MW 250 V 250 250 250 250 250 250 250 440 V 440 440 440 440 938 440 938 440 938 440 QW $ Price 78.00 108.00 138.00 287.00 287.00 360.00 360.00 398.00 398.00 795.00 725.00
LX4FF 024 035 048 060 070 110 125 LX4FG 024 035 048 060 070 110 125 024 035 048 060 070 110 125 LX4FH LX4FJ 048 060 070 110 125 F400 LX9FJ c 918 926 927 048 060 070 110 125 LX4FK F500 LX9FK c 918 926 927 048 060 070 110 125 LX4FL F630 918 926 927 LX9FK c F780 LX4FX a 110 125 F800 LX4F8 b FW FW a LC1F780 contactors operate on 2 coils as a set. The LX4FX part number includes both coils. b Also requires rectifier DR5TE4U, $72.00 list price. c Coil Circuit requires a separately mounted resistor. Order from Table 18.68 below.
24 V
36V
48 V
60 V
72 V
18
IEC CONTACTORS AND STARTERS
Table 18.68:
Coil LX9FJ918 LX9FJ926 LX9FJ927 LX9FJ932 LX9FJ938 Resistor Catalog Number DR2SC0047 DR2SC0030 DR2SC0390 DR2SC1200 DR2SC4700 Qty. Required $ Price 1 1 1 1 1 13.70 13.80 13.70 13.70 13.70 Coil LX9FK918 LX9FK926 LX9FK927 LX9FK932 LX9FK938 Resistor Catalog Number DR2SC0039 DR2SC0220 DR2SC0330 DR2SC1000 DR2SC3300 Qty. Required 1 1 1 1 1 $ Price 13.70 13.70 13.70 13.70 13.70 Coil LX9FL918 LX9FL925 LX9FL926 LX9FL931 LX9FL937 Resistor Catalog Number DR2SC0047 DR2SC0270 DR2SC0330 DR2SC1000 DR2SC3900 Qty. Required 2 2 2 2 2 $ Price 13.70 13.70 13.70 13.70 13.70
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47
18-20
I12
Discount Schedule
Enclosed Starters
www.schneider-electric.us
TeSys D enclosed full voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The enclosed D-line accepts standard D-Line accessories and all Insta-Kits control units and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office. Table 18.69:
1 Phase 115
0.333 0.5
1 2 2 3 3 5 7.5
Table 18.70:
Max. Horsepower Ratings (AC3) 3 Phase 200V 2 3 5 5 7.5 10 12 20 30 230 V 2 3 5 7.5 10 10 15 20 30 460 V 5 7.5 10 15 20 30 40 40 60 575 V 7.5 10 15 20 25 30 40 50 60
Table 18.71:
iOverload
LE1D093A62 O G 7 1 07
Base Catalog Number Wiring Method Control Power Transformer f Contactor/Starter Coil Voltage g Coil Frequency h Overload Relay Type j Overload Relay Range i
fControl
Power Transformer Add price from page 18-23. Select letter for primary voltage of CPT:
Voltage No Transformer used 208 240 480 600 Code Oa L M T X a Letter O, not zero. Note: If control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. Also, DC voltages are not available when control power transformer is used. gContactor/Starter
hCoil
Frequency
Select: 7 = dual frequency coils (50/60 Hz.) 6 = 60 Hz. D=DC Note: For 9 to 65 A contactors, only dual frequency coils are available; 80 A contactors, the 24 V to 240 V coils are dual frequency only (50/60 Hz.). The 480 V to 600 V coils are 60 Hz. only. See catalog for other restrictions. jOverload
0.10.16 60. 0.160.25 60. 0.250.40 60. 0.400.63 60. 0.631.0 60. 1.01.6 60. 1.62.5 60. 2.54 60. 46 60. 5.58 60. 913 107. 710 62. 913 62. 1218 107. 1218 62. 1624 62. 22 1725 62. 1725 107. 25 1725 107. 30 23-28 73. 32 2332 73. 32 2332 107. 40 3040 107. 50 3750 107. 53 3038 107. 55 3040 107. 57 3750 107. 59 4865 107. 61 5570 107. 63 6380 107. 65 4865 107. b Available for Class 10 only. c Available for Class 20 only. Note: If no overload relay is required, leave this portion of the catalog blank. Add appropriate Price Adder to the base price of the starter. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48
relay type
I11
Discount Schedule
18-21
18
IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. All devices provide Type 2 Coordination through 30 hp at 460 V. Devices are available in Type 1 and Type 12/3R enclosures. The IEC combination starter line accepts standard TeSys D accessories and all Insta-Kits pilot devices and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office. NOTE: Use tables and notes from page 18-21 to complete the catalog numbers. Table 18.72: Enclosed full voltage non-reversing fusible combination starters
3 Phase 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 Fuse Clip Rating Amperes 30 A 30 A 30 A 30 A 60 A 60 A UL Class CC CC J J J J Auxiliary Contacts N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number Type 1 LE1D096B62 LE1D126B62 LE1D186B62 LE1D256B62 LE1D326C62 LE1D406C62 $ Price 426. 468. 484. 500. 653. 708. Catalog Number Type 12/3R LE1D096B72 LE1D126B72 LE1D186B72 LE1D256B72 LE1D326C72 LE1D406C72 $ Price 551. 592. 607. 623. 829. 877.
Table 18.73:
18
IEC CONTACTORS AND STARTERS
Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30
Table 18.74:
Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30
Table 18.75:
Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30
Table 18.76:
Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30
Table 18.77:
Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30
18-22
I11
Discount Schedule
Add the Factory Modification Code to the end of the catalog number created from page 18-21. With the use of INSTA-KITS, only one operator scheme is allowed. Only the combinations of operators and pilot lights shown below can be ordered. Pilot lights will be at the coil voltage indicated in the catalog number for the starter. Table 18.78:
Description Factory Modification Codea $ Price Insta-Kits (for field installation) $ Price
Start/Stop
L1 OFF 1 23 61 ON
L2
X1 PL 4 A M
X2 OLR B 95 96 X2 PL
62
X1
OFF
HAND AUTO 3 4
4 61 62 X1 PL X2
L1
L2
L3
13
B
M A
14 98 96
97
95
Control Units Only For-rev-stop Push Button A06L 131. LA9CA06LT 71.00 Start/Stop Push Button A06G 65. LA9CA06GT 32.80 I/O (Start/Stop) Push Button N/A N/A I/O Push Button (double touch) A06I 83. LA9CA06IO 41.50 Emergency Stop N/A N/A Hand-Off-Auto Selector Switch A06E 65. LA9CA06ET 32.80 On/off Selector Switch A06D 65. LA9CA06DT 41.50 Start/Mushroom Head Stop Push Button A06X 65. LA9CA06XT 63.00 Pilot Lights only LED Pilot light, 24, 120 or 240 V A16S 134. LA9CA16STd 66.00 Green-Red Pilot light, Direct supply, 24 or 120 V b A06S 112. LA9CA06STd 62.00 Green-Red Transformer Pilot Light, 120, 208/240, 480 A06F 207. LA9CA06FTd 113.00 or 600 V b Available combination of control units and pilot lights Hand-Off-Auto Selector Switch w/24, 120 or 240 V A16U 213. LA9CA16UTd 177.00 LED Pilot Light Start/Stop Push Button w/ 24, 120 or 240 V LED Pilot A16V 213. LA9CA16VTd 177.00 Light On/off Selector w/ 24, 120 or 240 V LED Pilot Light A16W 213. LA9CA16WTd 177.00 Start/Stop Push Button w/ Green-Red Transformer A06N 177. LA9CA06NTd 95.00 Pilot Light Start/Stop Push Button w/Green-Red Pilot Light A06V 177. LA9CA06VT 95.00 Hand-Off-Auto Selector Switch w/Green-Red Pilot A06U 273. LA9CA06UT 97.00 Light Hand-Off-Auto Selector Switch w/Green-Red 147.00 A06J 273. LA9CA06JTd Transformer Pilot Light On/off Selector w/Green-Red Pilot Light A06W 177. LA9CA06WT 95.00 On/off Selector w/Green-Red Transformer Pilot Light A06H 273. LA9CA06HTd 147.00 Control Power Transformer Standard VA, 2 fuses in Primary, 1 Fuse in secondary A206P 260. c 50 VA extra, 2 fuses in Primary, 1 Fuse in secondary A207P 456. c 100 VA extra, 2 fuses in Primary, 1 Fuse in secondary A208P 634. c a Add these forms to the catalog number selected on page 18-21. The numbers as shown are for use in NEMA 1 Enclosures. For uses in NEMA 12/3R change the 6 to a 7 (ex A06U becomes A07U). Price remains the same. The change DOES NOT apply to control power transformer forms. b Pilot lights are wired such that the light is on when the contactor is energized. For non-LED type pilot lights, a green lens is installed on the unit when shipped. A red lens is included for use as applicable. c Select Insta-Kits from table below.
Table 18.79:
T1 T2 T3
Total VA Insta-Kits Catalog Number $ Price 50 LA9TFD32d 140.00 100 LA9TFD80d 246.00 150 LA9TFD15d 343.00 Complete the part number for the Insta-Kits by selecting the voltage code from the appropriate tables below.
L1 L2 L3
Table 18.80:
Voltage (Vac) Code
21
21
B F A
+
22
B R A
+
22
Table 18.81:
Primary Voltage Secondary Voltage Code
97
95
98
96
"C"
T1 T2 T3
I11
Discount Schedule
18-23
18
Contactors
3-Pole Non-Reversing Mini-Contactors
Table 18.82:
1
AC operating coils
Maximum Current Type of Connection 3 Auxiliary Contacts N.O. Screw-clamp Screw-clamp Screw-clamp 1 1 1 N.C. 1 1 1 LC1K0610 a b LC1K0601 ab LC1K0910 ab LC1K0901 ab LC1K1210 ab LC1K1201 ab 57. 57. 75. 75. 86. 86. Catalog Number $ Price
Inductive Resistive AC3 AC1 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes 0.5 0.5 1.5 1.5 1.5 1.5 2 3 1.5 3 3 3 5 7.5 3 5 10 6 9 12 15 20 20
LC1K0610G7
0.5
Table 18.83:
Coil voltage codes for AC contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example J72. Price adder $10.00.
12 J7 24 B7 42 D7 48 E7 110 F7 120 G7 127 FC7 200/ 208 L7 220/ 230 M7 230 P7 230/ 240 U7 277 UE7 380/ 400 Q7 400/ 415 N7 440 R7 480 T7 660/ 690 Y7
Volts AC 50/60 Hz
18
0.5 0.5
Code
Table 18.84:
1.5 1.5 1.5
DC operating coils
1.5 2 3 1.5 3 3 3 5 7.5 3 5 10 6 9 12 15 20 20 Screw-clamp Screw-clamp Screw-clamp 1 1 1 1 1 1 LP1K0610 ab LP1K0601 ab LP1K0910 ab LP1K0901 ab LP1K1210 ab LP1K1201 ab 75. 75. 92. 92. 106. 106.
LP1K0610
0.5
Table 18.85:
Coil voltage codes for DC contactors Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price adder $10.00.
12 JD 20 ZD 24 BD 36 CD 48 ED 60 ND 72 SD 100 KD 110 FD 125 GD 200 LD 220 MD 230 MPD 240 MUD 250 UD
Volts DC Code
,
Table 18.86:
0.5 0.5 1.5 1.5 1.5
LP4K06105
0.5
Table 18.87:
a b
Volts DC 12 24 48 Code JW3 BW3 EW3 For TeSys K contactors with spring terminal clamps, add a 3 before the coil voltage code (ex. LC1K06103G7). For TeSys K contactors with solder pin terminals, add a 5 before the coil voltage code (ex. LC1K09105B7). For TeSys K contactors with slip-on terminals, add a 7 before the coil voltage code (ex. LC1K12107M7). Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
Table 18.88:
Class 10, Relay setting rangeA 0.1 to 0.16 0.16 to 0.23 0.23 to 0.36 0.36 to 0.54 0.54 to 0.8 0.8 to 1.2 1.2 to 1.8 1.8 to 2.6 2.6 to 3.7 3.8 to 5.5 5.5 to 8 8 to 11.5 10 to 14
LR2K0316
AC or DC protection Ambient compensated bimetallic Class 10 Single phase sensitivity Manual or auto reset Full load current dial
18-24
I11
Discount Schedule
Contactors
www.schneider-electric.us
AC operating coils
Maximum Current 575V hp 3 5 10 Inductive Resistive AC3 AC1 A A 6 9 12 15 20 20 Type of Connection 3 460V hp 3 5 7.5 Auxiliary Contacts N.O. Screw-clamp Screw-clamp Screw-clamp 1 1 1 N.C. 1 1 1 LC2K0610 ab LC2K0601 ab LC2K0910 ab LC2K0901 ab LC2K1210 ab LC2K1201 ab 130. 130. 167. 167. 191. 191. Catalog Number $ Price
LC2K09107
Table 18.90:
Coil voltage codes for AC contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example J72. Price adder $20.00.
12 J7 24 B7 42 D7 48 E7 110 F7 120 G7 127 FC7 200/2 08 L7 220/ 230 M7 230 P7 230/ 240 U7 277 UE7 380/ 400 Q7 400/ 415 N7 440 R7 480 T7 660/ 690 Y7
Table 18.91:
0.5 0.5 0.5 1.5 1.5 1.5
DC operating coils
1.5 2 3 1.5 3 3 3 5 7.5 3 5 10 6 9 12 15 20 20 Screw-clamp Screw-clamp Screw-clamp 1 1 1 1 1 1 LP2K0610 ab LP2K0601 ab LP2K0910 ab LP2K0901 ab LP2K1210 ab LP2K1201 ab 167. 167. 202. 202. 232. 232.
Table 18.92:
Coil voltage codes for DC contactors Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price adder $20.00.
12 JD 20 ZD 24 BD 36 CD 48 ED 60 ND 72 SD 100 KD 110 FD 125 GD 200 LD 220 MD 230 MPD 240 MUD 250 UD
LP2K0910
Volts DC Code
Table 18.93:
0.5 0.5 0.5 1.5 1.5 1.5
Table 18.94:
LP2K09105
a b
Volts DC 12 24 48 Code JW3 BW3 EW3 For TeSys K contactors with spring terminal clamps, add a 3 before the coil voltage code (ex. LP2K09103BD). For TeSys K contactors with solder pin terminals, add a 5 before the coil voltage code (ex. LP5K09105BW3). For TeSys K contactors with slip-on terminals, add a 7 before the coil voltage code (ex. LC2K06107B7). Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-24 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-27 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49
I11
Discount Schedule
18-25
18
Contactors
Table 18.95:
1 PH 115 V hp 230 V hp
AC Operating Coils
Maximum Horsepower Ratings 3 PH 200 V hp 230 V hp 460 V hp 575 V hp Maximum Current Inductive Resistive AC3 AC1 A A Type of Connection Power Poles N.O. N.C. Catalog Number $ Price
4-Pole Mini Contactor 0.5 1.5 2 3 5 5 10 5 10 9 12 9 12 15 20 20 20 Screw-clamp Screw-clamp Screw-clamp Screw-clamp 4 2 4 4 4 2 LC1K09004 ab LC1K09008 ab LC1K12004 ab LC2K09004 ab LC2K12004 ab 75. 81. 86. 167. 191.
LC2K090045
0.5 1.5 3 3 7.5 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5
Table 18.96:
Coil voltage codes for AC contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example J72. Price adder $10.00 ($20.00 for mechanically interlocked contactors)
12 J7 24 B7 42 D7 48 E7 110 F7 120 G7 127 FC7 200/208 220/230 L7 M7 230 P7 230/ 240 U7 277 UE7 380/400 400/415 Q7 N7 440 R7 480 T7 660/690 Y7
Volts AC 50/60 Hz
Code
Table 18.97:
DC operating coils
2 3 5 5 10 5 10 9 12 9 12 15 20 20 20 Screw-clamp Screw-clamp Screw-clamp Screw-clamp 4 2 4 4 4 2 LP1K09004 ab LP1K09008 ab LP1K12004 ab LP2K09004 ab LP2K12004 ab 92. 98. 106. 202. 232.
18
IEC CONTACTORS AND STARTERS
0.5 1.5 3 3 7.5 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5
Table 18.98:
Coil voltage codes for DC contactors Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price adder $10.00 ($20.00 for mechanically interlocked contactors)
12 JD 20 ZD 24 BD 36 CD 48 ED 60 ND 72 SD 100 KD 110 FD 125 GD 200 LD 220 MD 230 MPD 240 MUD 250 UD
Volts DC Code
Table 18.99:
0.5 1.5
0.5 1.5 3 3 7.5 4-Pole Mechanically Interlocked Contactors 0.5 0.5 1.5 1.5 2 3 3 3 5 7.5
5 10
9 12
20 20
Screw-clamp Screw-clamp
4 4
238. 274.
a b
Overload Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-24 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49
18-26
I11
Discount Schedule
LA1KN11
LA1KN22
LA2KT2U
I11
Discount Schedule
18-27
18
Timing Range Voltage (V) Type (S) 24 to 48 Vac or Vdc On-delay 1 to 30 110 to 240 Vac On-delay 1 to 30 Relay outputs, with single pole double throw, 240 Vac/dc, 2 A max. Maximum switching capacity 250 VA / 150 W Operating temperature: -10 to + 60C (14 to 140F) Reset time: 1.5 s during time delay, 0.5 after time delay
Motor Starters
The TeSys U motor starter is integrated, simple to choose and to install, consisting of a control unit snapped in a power base. TeSys U can be configured to fit specific applications as well. Optional accessories: reverser, current limiter, predictive maintenance options and communication options. To get details information about TeSys U, visit our web at www.us.schneider-electric.com/TeSysU.
1 Power Base
Control Unit
18
IEC CONTACTORS AND STARTERS Power Base Control Unit Auxiliary Contact E164862 CCN NLDX LR43364 Class 3211 08
Ready condition Fault condition Ready condition Screw Fault condition Auxiliary Contact Function Modules Screw Screw Screw Pole state Pole state
O I O O O O I O
I I I O O I I
I I I O I O O
Screw Pole state 2 N.C. 1 I O I a Iindicates closed contact; Oindicates open contact b Requires multifunction or advanced control unit plus fault differentiation module LUFDA10.
Accessory Current Limiter Reverser Line phase barrier Multifunction Control Unit Function modules Communication modules Soft Starter + TeSys U Powerbus Configuration and connection accessories
Quick Description Increases the breaking capacity to 130kA @ 460 V Stacked or side mounted Required for use as a self-protected combination starter (UL508E) Has functions for monitoring and predictive maintenance Fault differentiation, Thermal overload, Motor load indication Integrates into existing networks, major portocols are available Use Altistart U01Soft Starter with TeSys U Use TeSys U with a prewired system PowerSuite software, busbar, external handle
For details & selection, see pages: 18-30 18-30 18-30 18-30 18-30 18-31 18-32 18-31 18-31
18-28
I11
Discount Schedule
Control Units
www.schneider-electric.us
Standard Reference Protection type Class 10 Class 20 Class 530 Single Phase: LUCC Class 10 only Protection functions Short circuit Over current Thermal overload Phase loss Phase imbalance Ground fault Under load, long start, jam Control functions Manual reset Automatic or local/remote reset Fault differentiation Thermal alarm Motor load display Fault history Alarm Threshold adjustment Tripping test LUCA LUCB
Multifunction LUCM
= built-in the control unit = works with the related function modules (see Table 18.119 on page 30)
Control Unit or mMultifunction Control Auxiliary Function or Communication Module Auxiliary Contact Block
Side View
18-29
18
Accessories
For use as a self protected combination starter, UL508E, incoming line phase barrier must be used. a See page 18-29 for placement on the power base.
12 3 With screw terminations 32 10 b See page 18-29 for placement on the power base. c Voltage code required.
18
IEC CONTACTORS AND STARTERS
g h i
Increases the breaking capacity of the motor starter. See page 18-29 for placement on the power base.
615.00
l m
Alarm differentiation
Provides indication between an overload trip Advanced control units only and a short circuit trip.
Parallel wiring
Signals when the motor current reaches 1.05 of the full load setting on the control unit. Provides a signal proportional to the average currents in the three phases divided by the full Motor load indication load current setting of the control unit. The output corresponds to a load status of 02 times the full load setting of the control unit. Provides a convenient way to reduce control wiring and allow for connecting starters to a Parallel wiring communications network by providing 24 Vdc for the starters. n Offers customization for specific application requirements. o See page 18-29 for placement on the power base.
LUFV2
188.00
Advanced or multi-function control units(24 Vdc only) and LU9G02 LU9BN11C or LU9MRC pre- splitter box and PLC network wired connector
LUFC00
57.00
18-30
I11
Discount Schedule
Accessories
www.schneider-electric.us
AS-Interface
188.00
ASILUFC51
188.00
Modbus
LULC033
218.00
LULC15
218.00
DeviceNet
LULC08
218.00
LULC14
218.00
LULC07
218.00
LULC09
218.00
Operating handle (NEMA 12) Use with LU9AP00 Control circuit filters r Use with electronic or triac output controllers See page 29 for placement on the power base.
Powerbus
Table 18.122: GV2 Cabling AccessoriesBus Bars
Description Application For feeding 2 GV2 starters or TeSys U For feeding 3 GV2 starters or TeSys U For feeding 4 GV2 starters or TeSys U For feeding 5 GV2 starters or TeSys U Pitch 45 54 72 45 54 45 54 72 54 Standard Pack 1 1 1 1 1 1 1 1 1 Catalog Number GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 GV2G554 $ Price Each 23.30 23.30 23.30 28.70 28.70 34.20 34.20 34.20 34.20
For the complete line of TeSys U-Line motor starter accessories and all technical details (specifications, wiring diagrams, etc.) pertaining to the product line, refer to Catalog 8502CT0201.
I11
Discount Schedule
18-31
18
125.00
Profibus
Soft Starters
3-Phase supply voltage: 200 ... 480 V 50/60 Hz 1 2 6 1.5 3 2 5 9 3 7.5 12 5 10 22 7.5 15 10 20 32 a Standard motor power ratings, HP power ratings indicated according to standard UL 508.
18
IEC CONTACTORS AND STARTERS ATSU01
b
HP HP 1 2 ATSU01N206LT LUC05BL 1.5 3 ATSU01N206LT LUC12BL 2 5 ATSU01N209LT LUC12BL LUB 12 3 ATSU01N212LT LUC12BL 7.5 ATSU01N212LT LUC 18BL 5 10 ATSU01N222LT LUC18BL 7.5 15 ATSU01N222LT LUC32BL LUB 32 10 20 ATSU01N232LT LUC32BL Depending on the configuration of the chosen TeSys U starter, replace the with A for standard, B for advanced, and M for multifunction. See page 18-28 for a complete list of available control units. Control voltage must be 24 Vdc.
18-32
CP1G
I11
Discount Schedule
Starters
www.schneider-electric.us
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in one compact unit. Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220 amps. The GV family of products may also be used in group motor installations in accordance with National Electric Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts and less wiring necessary for installation when compared to conventional panel designs. The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter construction. These products have UL-listed short circuit current rating from 10100 KA depending on application size and voltage. See www.us.telemecanique.com for more information.
How to Order
GV2ME
To order the basic motor starter, select the model number (GV2ME, GV2P, or GV3P) with the appropriate thermal setting from the table below. The thermal trip range and setting should be determined from the motor nameplate fullload current. Table 18.126:
Maximum Horsepower Ratings Thermal Setting (A) 1 3 Group Motor Applications GV2/3M push button GV2/3P rotary handle $ Price 212. 212. 212. 233. 233. 233. 233. 233. 233. 233. 278. 278. 278. 278. 278. 404. 404. 404. 404. 504. 504. 504.
115 V 230 V 200 V 230 V 460 V 575 V Max. Fuse or Catalog Catalog $ Price hp hp hp hp hp hp Circuit Breaker Number Number 0.110.16 1200 A GV2ME01a 159. GV2P01 0.160.25 1200 A GV2ME02a 159. GV2P02 0.250.40 1200 A GV2ME03a 159. GV2P03 0.400.63 1200 A GV2ME04a 180. GV2P04 0.631 0.5 0.5 1200 A GV2ME05a 180. GV2P05 11.6 0.1 0.75 1 1200 A GV2ME06a 180. GV2P06 1.62.5 0.667 0.5 1 1.5 1200 A GV2ME07a 180. GV2P07 0.5 2.54 1/8 0.333 0.75 1 2 3 1200 A GV2ME08a 180. GV2P08 46.3 1/4 0.5 1.5 1.5 3 5 1200 A GV2ME10a 180. GV2P10 610 0.5 1.5 2 3 5 7.5 1200 A GV2ME14a 180. GV2P14 914 0.75 2 3 3 10 10 1200 A GV2ME16a 224. GV2P16 1318 1 3 5 5 10 15 1200 A GV2ME20a 224. GV2P20 1723 1.5 3 5 7.5 15 20 1200 A GV2ME21a 224. GV2P21 2025 2 3 5 7.5 15 20 1200 A GV2ME22a 224. GV2P22 2432 2 5 10 10 20 30 1200 A GV2ME32 224. GV2P32 913 0.5 1.5 3 3 7.5 10 GV3P13 New! 1218 0.75 2 5 5 7.5 10 GV3P18 1725 1.5 3 7.5 7.5 15 20 GV3P25 2332 2 3 10 7.5 20 25 GV3P32 3040 3 5 10 10 25 30 GV3P40 3750 3 7.5 15 10 30 40 GV3P50 4865 3 10 20 15 40 50 GV3P65 a For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
Table 18.127:
GV3P
Thermal Setting (A) 1 115 V hp 230 V hp 200 V hp 230 V hp 5 7.5 10 15 30 30 50 75 Maximum Horsepower Ratings 3 460 V hp 10 15 30 30 60 75 100 150 575 V hp 15 20 30 40 75 100 150 200 Catalog Number GV7RE20 GV7RE25 GV7RE40 GV7RE50 GV7RE80 GV7RE100 GV7RE150 GV7RE220 Toggle Operator Standard Interrupt $ Price 417. 417. 417. 417. 417. 456. 502. 502. High Interrupt Catalog Number GV7RS20 GV7RS25 GV7RS40 GV7RS50 GV7RS80 GV7RS100 GV7RS150 GV7RS220 $ Price 813. 813. 813. 813. 813. 891. 978. 978.
GV7RE20
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
I11
Discount Schedule
18-33
18
Starters Accessories
GVAU116
18
IEC CONTACTORS AND STARTERS GVAE11 GVAD0101 GVAN11
b c d e f g
Short circuit signaling contact Left Hand Side 1 SPDT 1 GV2 + GV3P Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P. Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted. The GVAD is always mounted next to the starter. For spring terminals add 3 to the catalog number. Example: GVAE113 One trip or one fault signaling can be fitted per GV3. Cannot be used with GV2GH7 insulator.
18-34
CP10
I11
Discount Schedule
Starters Accessories
www.schneider-electric.us
Table 18.132: Auxiliary contact blocks (auxiliary contact functions depends on location inside the device)
Description Standard Instantaneous Trip Indication Fault Indication Low Level Instantaneous Trip Indication Fault Indication Mounting Location Max. No. of Blocks 2 per device 1 per device 1 per device 2 per device 1 per device 1 per device Contact Type N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. Catalog Number $ Price
Inside Device
GV7AE11
35.70
Inside Device
GV7AB11
35.70
GV7AC01
Undervoltage Trip
Inside Device
1 per device
64.00
Shunt Trip
Inside Device
1 per device
64.00
Fault Indication
Inside Device
1 per device
72.00
GV7AD111
Operating Handles and Accessories Black rotary operating handle with black legend plate (mounts directly on device) Red rotary operating handle with yellow legend plate (mounts directly on device) Conversion accessory to mount device directly on panel door Black rotary operating handle with black legend plate and extension kit (185600 mm) Red rotary operating handle with yellow legend plate and extension kit (185600 mm) Padlocking device for toggle handle (max. 38 mm padlocks) i Wire size: GV7AC021#143/0; GV7AC022#14350 kcmil.
GV7AS055
GV7AP03
GV7AC021
GV7V01 GV7AE11
I11
Discount Schedule
18-35
18
Starters Accessories
45 mm wide (same dimensions as GV2ME) Available with screw clamp and spring type terminals Mounts directly to LC1D09D32 contactors (with use of GV2AF3 or GV2AF4) Meets application needs for fusible starter Uses GV2AE instantaneous contact blocks to open control circuits DIN rail mounted
Table 18.135:
IN mm Spring terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Screw clamp terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Spring terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Screw clamp terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Auxiliary main pole adder aM, gG 0.39 x 1.5 10 x 38 a Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block. Description Fuse Type Dimensions Use In US Markets US Markets European Markets European Markets European Markets Catalog Number LS1D303 LS1D30 LS1D323 LS1D32 LA8D324a $ Price 86. 86. 101. 86. 65.
90
18
IEC CONTACTORS AND STARTERS
Conforming to standards
LS1D30
Product approvals Protective treatment Ambient air temperature operation Wiring Number of conductors and cross sectional area (c.s.a.) Solid cable Flexible cable without cable end Flexible cable with cable end Resistance to mechanical impact conforming to IEC 60947-1 7-1-6 Tightening torque Sensitivity to phase failure
30
30
90
File LR81630 Class 3211 05 Shock resistance30 g (conforming to IEC 600 68-2-27) Vibration resistance5 g (5 to 150 Hz) (IEC 600 68-2-26) Ambient temperature: -40 to 176oF (-40 to +80oC) for storage -4 to 140oF (-20 to +60oC) open operation -4 to 104oF (-20 to +40oC) enclosed operation Maximum operating life25 operations per hour Operating current of magnetic trip is approximately 13 times maximum thermal trip (non-adjustable setting)
Rated voltage600 V Rated thermal current25 A (GV2), 63 A (GV3) Mechanical life: GV2:
100,000 operations
18-36
I11
Discount Schedule
Starters Accessories
www.schneider-electric.us
GV2GH7
1 5 10 1 10
LAD31
Protective end cover 3-pole flexible connector Conduit adapter (1 NPT) 2" Incoming line insulator For GV2P when used in UL 508 Type E applicationsa a Cannot be used with front-mounted auxiliary contact block.
LAD311
Key release (Ronis key no. 455) Turn to Release Latching / Padlockable Turn to Release Sealing kit For enclosures GV2MC01 and GV2MP01 110 V Green 110 V Red 110 V Orange 110 V White 220/240 V Green 220/240 V Red Pilot Light (neon) 220/240 V Orange 220/240 V White 380/440 V Green 380/440 V Red 380/440 V Orange 380/440 V White b Orders must specify multiples of quantities listed. c Supplied with IP55 sealing kit.
26.90
GV2AF3 / GV2AF4
I11
Discount Schedule
18-37
18
Application Top feed for use with bus bars Bottom feed, to be used with bus bars; can be fitted with GV1L3 current limiter To cover unused bus bar outlets For connecting a GV2 to an LC1D09 thru D25 contactor
Table 18.144: Splitter Boxes A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to create the desired line-up.
Description Type of Control-command Connection on Control System Side 1 x HE10 8I/8O 1 x HE10 16I and 1 x HE10 8O 50 A power and control splitter box Via module APP1C a AS-i a Connection to an APP1C module via APP2CX adaptor (LAD35). No. of I/O per Starter 1I/1O 2I/1O 2I/1O 1I/1O No. of Starters per Unit 2 4 4 4 2 4 2 4 Catalog Number LAD322 LAD324 APP2R4H1 APP2R4H2 APP2R2E APP2R4E APP2R2AS APP2R4AS $ Price 52.00 93.00 124.00 124.00 124.00 124.00 124.00 124.00
APP2R4H1
18
IEC CONTACTORS AND STARTERS LAD3B LAD33 APP2D1
Relay supplied mounted on the front panel of the control connection. The use of TeSys D low consumption contactors is recommended.
18-38
I11
Discount Schedule
Busbar Accessories
www.schneider-electric.us
The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tapoff are used. When using tap-offs, the nominal operating current of the bus bar (160 Amperes @ 35o) must not be exceeded. Table 18.149: 160 Ampere Three Phase Busbar System
Maximum number of mounting plates Tap-off IN mm 36 6 9 12 15 24 27 Standard Width Plate IN 2.13 4 6 8 10 16 18 mm 54 Extension Plate IN 2.80 2 3 4 5 8 9 mm 71 IN 13.39 17.64 21.85 26.05 38.69 42.90 mm 344 452 560 668 992 1100 AK5JB143 AK5JB144 AK5JB145 AK5JB146 AK5JB149 AK5JB1410 210.00 266.00 286.00 345.00 393.00 540.00 Length Catalog Number $ Price
AK5JB143
1.42
Table 18.150: Mounting Plate Tap-off Plugs into busbar mounted on AM1DL201 DIN rail.
Width
AK5PA231
mm 54 54 108
25 A 25 A 25 A
LUS or LUB 12 and 32 & GV2 GV2 & Contactor GV2 & Reversing Contactor
Table 18.151: Bus Tap-off Plugs into busbar for wiring to a separately mounted device.
Width
AK5PA232S
$ Price 23.00
IN 1.42 1.42
AK5PC33
Table 18.152: Extension Plates Used to mount wider components. Bolt to standard mounting plates (after DIN rails are removed).
Width Application IN 2.80 mm 71 GV & Reversing contactor AK5PE27 26.30 Catalog Number $ Price
Table 18.153: Mounting Rail Must be used for mounting plates with tap-offs.
Depth Description mm 75 mm Omega Rail 15 mm 2000 Length Catalog Number AM1DL201 $ Price 41.10
AM1DL201
I11
Discount Schedule
18-39
18
37.80
Application
Catalog Number
$ Price
Dimensions
.39 10
c c1 c2 c3
.39 10
.39 10
c c1 c2 c3
AC Coil
DC Coil
D09 to D18 IN (mm) 3.03 (77) D093 to D18 D099 to D189 IN (mm) 3.89 (99) IN (mm) 3.14 (80) D25 to D38 D183 and D323 DT20 and DT25 DT203 and DT253 DT32 to DT40 DT323 and DT403 IN (mm) 3.36 (85) IN (mm) 3.89 (99) 4.21 (107) 4.84 (123) a 5.19 (132) a 5.47 (139) a 3.54 (90) 3.62 (92) 3.89 (99) 3.97 (101) 4.84 (123) 5.19 (132) 5.31 (135) 5.66 (144) 5.62 (143) 5.78 (147) 5.98 (152) 6.14 (156) IN (mm) 3.34 (85) 3.85 (98) 4.48 (114) 5.02 (129) 7.48 (190) 3.54 (90) 3.62 (92) 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) IN (mm) 3.89 (99) 3.54 (90) 3.62 (92) 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) IN (mm) 3.58 (91) 3.85 (98) 3.93 (100) 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) IN (mm) 4.13 (105) 3.85 (98) 3.93 (100) 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155)
LC1 b
b1
c1 c2
c3 a b
AC coil, without add-on accessories DC coil AC coil, with LAD4BB b 3.70 (94) AC coil, with LA4D*2 b 4.33 (110) a AC coil, with LA4DF, DT b 4.68 (119) a AC coil, with LA4DR, DW, DL b 4.96 (126) a AC coil, without cover or add-on blocks 3.30 (84) AC coil, with cover, without add-on blocks 3.38 (86) DC coil, without cover or add-on blocks 3.66 (93) DC coil, with cover, without add-on blocks 3.76 (95) AC coil, with LADN or C (two or four contacts) 4.60 (117) DC coil, with LADN or C (two or four contacts) 4.96 (126) AC coil, with LAD6K10 5.07 (129) DC coil, with LAD6K10 5.43 (138) AC coil, with LADT,R,S 5.39 (137) AC coil, with LADT,R,S and sealing cover 5.55 (141) DC coil with LADT,R,S 5.76 (146) DC coil with LADT,R,S and sealing cover 5.90 (150) Including LAD4BB Not applicable to devices with DC coils
4.21 (107) 3.75 (95.5) 3.85 (98) 4.84 (123) a 4.30 (111.5) a 4.48 (114) a 5.19 (132) a 4.76 (120.5) a 4.84 (123) a 5.67 (139) a 5.0 (127.5) a 5.11 (130) a 3.30 (84) 3.30 (84) 3.54 (90) 3.38 (86) 3.38 (86) 3.62 (92) 3.66 (93) 3.66 (93) 3.89 (99) 3.76 (95) 3.76 (95) 3.97 (101) 4.60 (117) 4.60 (117) 4.84 (123) 4.96 (126) 4.96 (126) 5.19 (132) 5.07 (129) 5.07 (129) 5.31 (135) 5.43 (138) 5.43 (138) 5.66 (144) 5.39 (137) 5.39 (137) 5.62 (143) 5.55 (141) 5.55 (141) 5.78 (147) 5.76 (146) 5.76 (146) 5.98 (152) 5.76 (146) 5.76 (146) 6.14 (156)
5.20 (LA4 DA2, DE2) 132 5.59 (LA4 DF, DT) 142 5.91 (LA4 DM, DR, DW, DZ) 150
4.49 114
4.92 125
.51 13 (LA8)
.51 13 (LA8)
.51 13 (LA8)
.51 13 (LA8)
LC1 a with LA4 D2 with LA4 DB3 or LAD 4BB3 with LA4 DF, DT with LA4 DM, DW, DL without cover or add-on blocks c with cover, without add-on blocks with LAD N (1 contact) c1 with LAD N or C (2 or 4 contacts) c2 with LAD 6K10 or LA6 DK with LAD T, R, S c3 with LAD T, R, S and sealing cover b1
D40AD65A IN (mm) 2.17 (55) 5.35 (136) 6.18 (157) 6.54 (166) 4.65 (118) 4.72 (120) 5.91 (150) 6.42 (163) 6.73 (171) 6.89 (175)
DT60ADT80A IN (mm) 2.76 (70) 4.65 (118) 4.72 (120) 5.91 (150) 6.42 (163) 6.73 (171) 6.89 (175)
4.80 122
0.47 12
c1 c2 c3
18-40
4.61 117
b1
5.51 (LA4 DA2, DE2) 140 5.79 (LA4 DF, DT) 147 6.18 (LA4 DM, DR, DW, DZ) 157
5.00 127
5.00 127
18
IEC CONTACTORS AND STARTERS
D40008 IN (mm) 3.35 (85) 5.31 (135) 5.59 (142) 5.91 (150) 4.92 (125) 5.47 (139) 5.79 (147) 6.26 (159) 6.57 (167) 6.73 (171)
Dimensions
www.schneider-electric.us
5.20 (LA4 DC3) 132 5.47 (LA4 DF, DT) 139 5.75 (LA4 DM, DR, DW, DZ) 146
6.73 171
2.95(3P) 3.34(4P) 75 85
5.51 (LA4 DC3) 140 5.79 (LA4 DF, DT) 147 6.06 (LA4 DM, DR, DW, DZ) 154
.47 12
4.96 126
4.96 126
6.22 158
LA8
a b
6.85 (LA4D2, D3) 174 7.28 (DF, DT) 185 7.40 (DM, DR, DW, DL) 188
LA4
LR2D4 bimetallic overload relay Direct mounting beneath contactors LC1D115 and D150
LR9D solid-state overload relay Direct mounting beneath contactors LC1D115 and D150
10.51 267
7.44 189
5.91 150
5.20 132
4.72 120
AM1DE and ED .41 (10.5)
6.85 174
5.20 132
5.35 136
10.04 255
4.72 120
35 mm DIN rail dimensions AM1DP200 and DR200 d 0.10 (2.5) Note: All dimensions are in Inches (mm).
18-41
18
LC1D115, D150
= =
5.12 130
6.22 158
Dimensions
LC1F115 to F330
TeSys F Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
S
a
s1
All dimensions shown in mm. To convert to inches divide by 25.4. Table 18.158:
F115 F150 F185 F265 F330
LC1 a b b1 b2 c f G G1 J J1
433-Pole Pole Pole 4-Pole 163.5 200.5 163.5 200.5 162 162 170 170 137 137 137 137 265 265 301 301 165b 165b 165b 165b 131 131 131 131 106 143 106 143 80 80 80 80 106 106 106 106 120 120 120 120
343434Pole Pole Pole Pole Pole Pole 168.5 208.5 201.5 243.5 213 261 174 174 203 203 206 206 137 137 145 145 145 145 305 305 370 370 375 375 176 176 207 207 219 219 130 130 147 147 147 147 111 151 142 190 154.5 202.5 80 80 96 96 96 96 106 106 106 106 106 106 120 120 120 120 120 120 145 181 48 43 74 25 44.5 38 20.5 145 181 48 43 74 25 44.5 38 20.5
b2
P a
Q1 f
L 107 107 107 107 113.5 113.5 141 141 M 147 147 150 150 154 154 178 178 P 37 37 40 40 40 40 48 48 Q 29.5 29.5 26.5 26 29 29 39 34 Q1 60 60 57.5 55.5 59.5 59.5 66.5 66.5 S 15 15 20 20 20 20 25 25 S1 27 27 34 34 34 34 38 38 Y 44 44 44 44 44 44 38 38 Z 13.5 13.5 13.5 13.5 13.5 13.5 21.5 21.5 b +6 mm with time delay block (for F115 and F150). c Optimal terminal shroud Note: f = minimum distance required for coil removal.
J J1
b1
= Z
LC1F400 to F500
G1 G
= Y
8.23 209
b2
4.7 120
7.09 180
18
IEC CONTACTORS AND STARTERS
Table 18.159:
Voltage in V 220/380 415/440 500 660 1000 LC1F115, F150 20 25 30 40 20 LC1F185 20 25 30 40 30 LC1F265 20 25 40 50 40 LC1F330 25 35 40 50 50 Note: X1: Minimum clearance according to the operational voltage and the breaking capacity.
2.20 56
Table 18.160:
LC1 a b b2 c f F400 2-Pole 213 206 375 213 119 3-Pole 213 206 375 213 119 4-Pole 261 206 375 213 119 2-Pole 233 238 400 226 141 F500 3-Pole 233 238 400 226 141 80 66 120 170 156 210 39.5 146 208 55 46 77 30 4-Pole 288 238 400 226 141 140 66 175 230 156 265 34.5 146 208 55 46 77 30
L c
P a
Q1 f
8 X 8.5 dia.
Gd 80 80 80 80 G min. 66 66 66 66 G max. 102 102 150 120 G1d 170 170 170 170 G1 min. 156 156 156 156 G1 max. 192 192 240 210 d Supplied J 19.5 19.5 67.5 39.5 L 145 145 145 146 M 181 181 181 208 P 48 48 48 55 Q 69 43 43 76 Q1 96 74 74 102 S 25 25 25 30 e Protective cover. Note: f = Minimum distance required for coil removal.
Table 18.161:
Voltage in V 220/230 415/440 500 660 1000 LC1F400 30 40 40 50 60 LC1F500 40 45 50 60 60 Note: X1: Minimum clearance according to the operational voltage and the breaking capacity.
G .92 23.5 G1 J
Dual Dimensions:
INCHES Millimeters
18-42
Dimensions
www.schneider-electric.us
TeSys F Contactors
Refer to Catalog 8502CT9901
2.83 72 c =
1.57 40
2.52 64 6 x M12 x 45
Dual Dimensions:
INCHES Millimeters
4 x Dia. 10.5 mm = 11.97 304 10.39 264 11.02 280 18.28 464 =
X1 7.76 197
6.10 155
3.15 80
3.15 80 a
Q1
2.38 60
J1
9.84 250
7.13* 181
G max. IN 7.68 7.68 mm 195 195 275 IN 2.70 2.70 2.70 J1 mm 68.5 68.5 68.5 IN 4.02 2.36 2.36 Q mm 102 60 60 IN 5.00 3.50 3.50 Q1 mm 127 89 89 X1:Minimum clearance according to the operational voltage and the breaking capacity. Voltage in V X1 in mm 380 60 415/440 60 500 660 1000 60 70 80
LC1F630 IN * = minimum distance required for coil removal. c Protective terminal cover. LC1F780, F7804 2P 3P 4P 12.17 12.17 15.31 mm 309 309 389 IN 7.09 7.09 9.45 mm 180 180 240 IN 3.94 3.94 5.91 mm 100 100
150 10.83
.86 22
11.02 280
17.08 434
13.70 348
X1
6.30 160
X1: Minimum clearance according to the operational voltage and the breaking capacity. Voltage in V X1 in mm 380 90 415/440 100 660 120 1000 120
f Overall length (3 poles) a Overall length (4 poles) *minimum distance required for coil removal.
LC1F780 mounting
LC1F7804 mounting
5.00 127
8 x Dia. 10.5 mm
7.09 180
5.00 127
3.50 90
9.45 240
9.45 240
5.20 132
3.50 90
9.45 240
7.48 190
9.45 240
4.00 102
5.00 127
5.00 127
15.74 400
18-43
18
G supplied
G min.
7.09 180
Dimensions
G1
2xM0.16 2xM4
2.76 70
e2
G a
2.36 60
= c e2
1.57 40
G a
e2
1.57 40
IN (mm) DT20 and DT25 3.54 (90) DT32 to DT60 3.54 (90) c, e2: includes cabling.
LC2 or 2 x LC1
IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) D40 to D65 7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97) D80 and D95 8.14 (207) 5.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111) c, e1 and e2: includes cabling.
LC2 or 2 x LC1
e1
LC2D115 and D150 2 x LC1D115 and D150 Panel mounted with 1/4 screw Dimensions shown in millimeters (mm 25.4 = inches)
e1
6.22 158
e2
G a
c
LC2 or 2 x LC1 (3-pole) D115, D150 LC2 or 2 x LC1 (4-pole) D115 c, e1 and e2 includes cabling a 266 a 334 c 148 c 148
e1 56 e1
e2 18 e2 60
5.12 130
G 242/256 G 310/324
NOTE: For dimensions of TeSys F reversing contactors, please refer to Catalog 8502CT9901.
18-44
3.94 100
4.33 110
18
IEC CONTACTORS AND STARTERS
Dimensions
www.schneider-electric.us
LAD7B106
1.38 35
.39 10
.59 15
LAD7B106
1.81 46 =
=
3.15 80
1.97 50
1.50 38
3.15 80
.08 2
1.77 45
.24 6
.20 5
4.92 125
LAD703 a
3.54 90
DX1AP25
2x0.26 2x6.5
LRD, LR2D and LR9D Reset by flexible cable LA7D305 and LAD7305 Mounting with cable straight
4.33 110
Mounting with cable bent
1.26 32
e c e M10x0.04 M10x1
Separate mounting
LC1D pp A
7.28 185
3.43 87
4.57 116
2.17 55
4.84 123
2.17 55
LR2D2, LR3D2 Separate mounting at 50 mm (1.97) centers or on AM1DP200 or DE200 rail
2.17 55 1.57 40
LA7-D1064
1.77 45 1.38 35
LA7-D2064
3.11 79
0.16 4
1.97/2.56 50/65
3.54 90
0.12 3
1.48 43.5
3.86 98
2x0.18 2x4.5
0.31 8 0.67 17
3.86 98
1.71 43.5
1.97/2.56 50/65
2x0.18 2x4.5
0.51 0.87 13 22
= =
DX1AP25 LA7D1064
Mounting Holes
4.33 110
4.25 108
2 x 6.5 mm Screws
4.25 108
2 x 6.5 mm Screws
4.33 110
18-45
18
Dimensions
LC1 b c
D09D18 D25D38 4.84 (123) 5.39 (137) See Catalog 8502CT9901 pages 122, 123.
LC1 b c
18
IEC CONTACTORS AND STARTERS
a
LRD-3 Direct mounting beneath contactors LC1-D40 to D95 and LP1-D40 to D80 AM1 d DL201 0.28 (7) DL200 0.67 (17) b LC1D40 LC1D50 LC1D65 LC1D80 LC1D95 LC1D40, LP1D40 LC1D50 LC1D65, LP1D65 c e g(3P) 0.18 (4.5) 0.18 (4.5) 0.18 (4.5) 0.37 (9.5) 0.37 (9.5) 0.18 (4.5) 0.18 (4.5) 0.18 (4.5) g(4P) 0.51 (13) 0.51 (13) 0.87 (22) 0.51(13) 0.51(13) AC Control Circuit 4.37 (111) 4.69 (119) 2.85 (72.4) 4.37 (111) 4.69 (119) 2.85 (72.4) 4.37 (111) 4.69 (119) 2.85 (72.4) 4.55 (115.5) 4.88 (124) 3.03 (76.9) 4.55 (115.5) 4.88 (124) 3.03 (76.9) DC Control Circuit 4.37 (111) 6.93 (176) 2.85 (72.4) 4.37 (111) 6.93 (176) 2.85 (72.4) 4.37 (111) 6.93 (176) 2.85 (72.4)
3.03 (76.9)
0.37 (9.5)
0.87(22)
AM1DL200 and DR200 AM1DE200 and ED d 0.10 (2.5) 0.41 (10.5) For Additional characteristics and Catalog Number information, see Catalog 8502CT9901
18-46
Dimensions
www.schneider-electric.us
11
.22 6
.98 25
1.97 50
1.97 50 3.78 96
2.99 76
3.98 101
2.36 60
1.77 45
2.99 76
2.80 71
a b
4.53 115 1.85 .11 47 3 Terminal shroud LA9F70 6.5 x 13.5 for LR9F557 and 8.5 x 13.5 for LR9F563, F567, F569
4x5.5
4.53 115
.79 20
3.15 80 .79 20
3.15 80
.87 22
.55 14
13
.24 6
2.76 70
1.77 45
4.29 109
3.23 82
5.39 137
.24 6
5.94 151
1.57 40
P2 48 55
P1 48 55
3.03 77
7.60 193
3.03 77
H3
H3
H1
H2
d d LC1 contactors F115 F150 F185 F225 With LR9 relays F557, F563, F567, F569 F557, F563, F567, F569 F557, F563, F567, F569 F571 F775, F779 F265 F571 F775, F779 F330 F775, F779 F400 F775, F779, F781 F500 F775, F779, F781 F630 F781 Relay mounting plate, see page 18-16. Connection Accessories, see page 18-16. b 240 246 250 273 308 279 314 317 317 346 510 H1 30 30 30 40 50 40 60 60 60 70 110 H2 76 76 76 76 108.8 76 108.8 108.8 108.8 108.8 108.8 H3 120 120 120 120 120 120 120 120 180 180 180 LC1 contactors F115 F150 F185 F225 F265 F330 F400 F500 F630 With LR9 relays F557, F5 63, F567, F569 F557, F563, F567, F569 F557, F563, F567, F569 F571 F775, F779 F571 F775, F779 F775, F779 F775, F779, F781 F775, F779, F781 F781 b 279 283 285 319 360 332 363 364 364 390 509 H4 60 60 60 80 100 90 100 100 100 110 120 H2 76 76 76 76 108.8 76 108.8 108.8 108.8 108.8 108.8 H3 120 120 120 120 120 120 120 120 180 180 180
d e
H2
H4
18-47
18
2.05 52 2.60 66
9.02 229
7.44 189
2.44 62
1.57 40
7.87 200
2.80 71 4x5.5
2.36 60
.22 6
a q
2.24 57
1.89 48
1.89 48
4.72 120
b c
1.97 50 1.57 40
1.97 50 1.57 40
Dimensions
NEMA 1
D09-25 (FVNR)
10.00
254
5.00
127
7.50
191
8.00
203
3.00
76
7.50
191
18.00
356
.69
14.02
18
16.50
12.52
318
NEMA 12/3R
D09-25 (FVNR) D09-40 (FVR); D32-40 (FVNR)
10.00
254
5.00
127
419
457
18.88
480
14.88
18.00
378
14.00
15.63
356
19.63
397
499
.75
R C
19
F D/2
.56
18-48
14
457
18
IEC CONTACTORS AND STARTERS
8.00
203
7.75
197
3.00
76
7.75
197
Dimensions
www.schneider-electric.us
TeSys K Contactors
Refer to Catalog 8502CT9901
rail
1.97 50
4.57 116
2.56 65
Three-phase
1.77 45
2.28 58
3.15 80
1.50 38
.31 8
1.38 35
4 x 4
1.77 45
A1
13
14
A H
1 3 5 95 97
14
A2
Test Reset/Stop 2 97 4 95 6 98 96
KM1 A1
LA1-K
4 x 4
LA1-K
8 x 4
2.28 58
2.28 58
1.97 50
1.22 31
2.24 57
1.38 35 1.77 45
1.22 31
2.24 57
3.15 80
3.54 90
2.28 58
1.77 45
2.24 57
2.28 58
3.54 90
A1
.34 9 A1 A2
.34 A1 9
2.28 58
1.97 50 2.05 52
2.28 58
10 x .051 10 x 1.3
1.77 45
A2
20 x .051 20 x 1.3
1.77 45
1.77 45
Table 18.163:
LA2KT Electronic time delay contact blocks On mini-contactors or reversing mini-contactors
LA2-KT 1.06 27
2.28 58
1.97 50 2.05 52
A2
1.97 50
18-49
18
O
96 98 2 4 6
A2
96
95
13
Dimensions
Starter Controllers Non-reversing Rail Mounting Screw Mounting Reversing Rail Mounting Screw Mounting
126 4.96 X2
X1
29
30
1.18
1.14
4 .15
154 6.06
120/125 4.72/4.92
163 6.42
135a 5.31
45 X2 1.77
135a 5.31
X1
45 1.77
Note: Minimum electrical clearance: X1 = 35 mm for Ue = 440 V and 70 mm for Ue = 500 and 690 V, X2 = 0 a Maximum depth (with MODBUS communication module) Reversing block for mounting separately from power base Rail Mounting Screw Mounting
115 4.53
113 4.45
45 1.77
135a 5.31
a Door interlock mechanisms
45 1.77
154 6.06
93 3.66
LU9AP00
Door cut-out
43 1.69 = = 54 2.12
230 9.06
Dual Dimensions:
508 20.01
11.5 .45
8 .31
7 .27
18-50
= = 54 2.12
55 2.16
4x3.5 .13
INCHES Millimeters
233 9.17
18
IEC CONTACTORS AND STARTERS
Dimensions
www.schneider-electric.us
TeSys U combination (non-reversing power base) and ATSU 01N212LT Mounting on (35mm) rail with VW3 G4104 connector
TeSys U combination (non-reversing or reversing power base) and ATSU 01N2206LT to ATSU 01N212LT Side-by-side mounting
135 5.31 99 3.9
45 1.77
154 6.06
72.2 2.84
284 11.18
150 5.91
9 0.354
TeSys U combination (non-reversing power base) and ATSU 01N222LT to ATSU 01N232LT Mounting on (35mm) rail with VW3 G4104 connector
TeSys U combination (non-reversing or reversing power base) and ATSU 01N222LT to ATSU 01N232LT Side-by-side mounting
135 5.31
45 1.77
99 3.9
154 6.06
314 12.36
170 6.69
9 0.354
20 0.79
46.6 1.83
9 0.354
18-51
18
9 0.354
72.2 2.84
124 4.88
Dimensions
GV2M
GV2AE
15 .59
Mounting of GV2M
On 35 mm rail C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm) C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm)
89 3.5
10 .39
11 .43
9.3 .37
18 .71 c
GV2P
GV2AK00
Mounting of GV2P
On 35 mm rail C = 98.5 mm (3.88") on AM1DP200 (35 x 7.5 mm) C = 106 mm (4.17") on AM1DE200, ED200 (35 x 15 mm) 44.5 1.75
89 3.50
45 1.77 61 2.40
32 1.26
44.5 1.75
44.5 1.75
44.5 1.75
15 .59
9.3 .37
18 .71
44.5 1.75
44.5 1.75
26 1.02
50 1.97 82 3.23
44.5 1.75
13.5 .53
103 4.07
c1 c d1 d
45 1.77
191 7.50
c1 c
45 1.77
44 1.73
GV2ME + b c1 c d1 d
LC2D09 to D18 7.4 (188.6) 3.6 (92.7) 3.9 (98.2) 3.9 (98.3) 4.1 (103.8) Surface mounting enclosure GV2MC0 a
LC2D25 and D32 7.8 (199) 3.9 (99) 4.11 (104.5) 3.9 (98.3) 1.4 (103.8)
GV2P + b c1 c
(bracket cut-out)
2x5.3x6.3
b1
147 5.79
130 5.12
84 3.31
93 3.66
13 0.51
6.5 0.25
b1 mm 127 117
18-52
84 3.31
18
IEC CONTACTORS AND STARTERS
Dimensions
www.schneider-electric.us
35 1.38
152 6.0
152 6.0
135 5.31
55 2.17
45 1.77
79 3.11
45 1.77
90 3.54
24 .94
9.5 .37
54 2.13
7.5 mm height compensation plate GV1F03
Door cut-out
65 2.56
7 .276
5 .2
53 2.1
=
5.2 0.21 = =
= 54 2.13
80 3.15
35 1.38
13 0.51
35 1.38
Sets of bus bars, GV2G445, GV2G454, GV2G472 with terminal block GV2G05
2.5 63
1.2 30
.12 3
.71 18
1.8 45
I 7.0" (179 mm) 8.1" (206 mm) 10.2" (260 mm) P 1.8" (45 mm) 2.1" (54 mm) 2.8" (72 mm) GV3 P Dimensions Mounting on rail AM1 DE200 or AM1 ED201 I 3.5" (89 mm) 3.9" (98 mm) 4.6" (116 mm) 6.0" (152 mm)
0.08 x 1.8" (2 x 45 mm) 0.08 x 2.1" (2 x 54 mm) 0.08 x 2.8"(2 x 72 mm) 0.12 x 2.1" (3 x 54 mm)
(1)
X1
(2)
68
132
64
X1
136
55
144
18
X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V, 50 mm for Ue < 690 V Mounting on panel, using M4 screws
Blocks GV ANpp , GV ADpp , GV AM11 Block GV3 AUpp and GV3 ASpp Mounting on pre-slotted mounting plate AM1 PA
64
68
183
AF1 EA4
137,5
3x4
136
37,5
136
18,7 18,7
Note: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional sales office.
137,5
16
18-53
18
Dimensions
2x0.24 2x6 =
1.85 3.0 47 76
= 4.25 108
x2
4.92 125
1.14 29
3.46 88
== 1.14 29
3.27 83
= = 4.25 108
Minimum clearance Painted or insulated metal plate, insulation or insulated bar Bare metal plate U < 440 V 440 V < U < 600 V
x1
x1
Note: Minimum distance between 2 units mounted side by side = 0. Motor controllers GV7R Add-on auxiliary contacts, GV7AE11, GV7AB11
1/L1
5/L3
3/L2
14
12
94
92
84
82
x2
U > 600 V
0.79 (20)
1.38 (35)
11
91
81
Note: A self-adhesive label, supplied with the contact, can be affixed to the front face of the starter to allow personalized marking according to the function of the contact or contacts.
2/T1
GV7AU
4/T2
6/T3
GV7AS
GV7AD111, AD112
D1
C1
97
D4
C2
97
97
KA1 98 14 98
13
50 ms
50 ms
23
98
21
24
50 ms
22 A2 A1 22 21
KA1 24
A1
B1
KA1
KA1 A2
KM1
18-54
4.25 108
18
IEC CONTACTORS AND STARTERS
Dimensions
www.schneider-electric.us
GV7AC03 Spreaders
Smooth Terminals
0.41 10.5 a Z 0.75 19
Connectors
Z
2.76 70
2.76 70
Flush Mounting
1.77 2.87 45
DD
60
1.85 3.0 47 76
60
73
6.10 155
3.58 91
3.5 89
3.82 97
18-55
18
1.14 29
Dimensions
4.72 120
0.35 9
3.94 100
2.32 59
1.61 41
4.92 125
4.72 120
2.72 69
2.0 51
=
3.94 100
Door cutouts require a minimum distance between the center of the manual motor protector and the door hinge point (h) of d >/= 3.94 in (100 mm) + (h x 5)
60
0.35 9
=
=
60 l
= 2.95 75 Note: I: 7.28" (185 mm) minimum, 23.62" (600 mm) maximum. The shaft of the extended rotary handle GV7AP01 or GV7AP02 must be cut to length: I - 4.96" (126 mm)
18-56
2.95 75
18
IEC CONTACTORS AND STARTERS
Table of Contents
Section 19
Push Buttons and Operator Interface
Product Panorama
Push Buttons Control Stations Pendant Stations Tower Lights 19-2 19-4 19-5 19-6
19-8
16 mm Push Buttons
XB6 16 mm Push Buttons, selector switches, and pilot lights with a plastic bezel are intended for machine adjustment and setup.
22 mm XB4 (p. 19-23) 22 mm XB5 (p. 19-42)
19-12
22 mm Push Buttons
XB4 22 mm Push Buttons, selector switches, and pilot lights with a metal bezel are 19-23 designed for industrial applications. They combine ease of installation and robustness. XB5 22 mm, the plastic version of the XB4 unit, is particularly suited to applications 19-42 requiring a resistance to chemical agents and/or double electrical insulation. XB5 Biometric Switches 19-123
30 mm Push Buttons
Class 9001 Type K Heavy Duty Oiltight/Watertight Push Buttons are intended primarily for machine tool and industrial applications. Class 9001 Type SK Non-Metallic Watertight operators are designed for use in highly corrosive areas. Class 9001 Type KX operators are Square Multifunction Control Units that mount in a Type K mounting hole. This highly versatile line saves space by combining push buttons and pilot lights into one common operator. 19-63 19-73 19-90
PUSH BUTTONS AND OPERATOR INTERFACE
Tower Lights and Beacons. XVB, XVC, XVE, and XVP tower lights and beacons provide long distance indication of the operation status or sequences of a machine with with lights or buzzers.
19-107
Pendant Stations
Our full line of pendant stations for most crane and hoist applications range from the 19-113 light to medium duty BW and XAC pendants to the heavy duty SKYP pendants.
Foot Switches
Type A Foot Switch (p. 19-119) Rotary Cam Switch (p. 19-121)
The Type A foot switch is a heavy duty industrial foot switch which can be used in a variety of industrial applications.
19-119
19-1
19
Tower Lights
Selection Guide
Refer to Catalog 9001CT0001
www.schneider-electric.us
Type J
XB6
XVLA1
XVLA2
XVLA3
Type of Product Mounting Hole Diameter Mini Pilot Light 8 mm / 12 mm UL Recognized File E164353, CCN NKCR CSA File LR44078, Class 3211-03 Compact Pilot Light 17.5 mm (0.68 in) UL Recognized File E179183, CCN NKCR CSA File LR25490, Class 3211-03 Compact Pilot Light 17.5 mm (0.68 in) UL File E78403, CCN NKCR CSA File LR25490, Class 3211-03 16 mm Push Button (plastic) 16.2 mm UL File E164353, CCN NKCR CSA File LR44087 Class 3211-03 CE marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5 EN/IEC 60204-1 and EN/ISO 13850: 2006 (trigger action and mechanical latching Emergency Stop push buttons) JIS C 4520 and 853 UL 508 and CSA C22-2 no. 14 NEMA 13 NEMA 4, 13 IP65 NEMA 1, 4, 4X, 12
Approvals
Conforming to Standards
25 mA
6-30 Vac/Vdc: 15 mA 48120 Vac: 20 mA AC-15; B300 Ue = 240 Vac and le = 1.5A Ue = 120 Vac and le = 3 A Continuous 5 A DC-13; R300 Ue = 250 Vdc and le = 0.1 A Ue = 125 Vdc and le = 0.22 A
19
PUSH BUTTONS AND OPERATOR INTERFACE
Connection Type
Faston
Quick Connect/ Solder Tabs 0.11 x 0.02 in. (2.8 x 0.5 mm)
19-10
19-13
19-2
Selection Guide
Refer to Catalog 9001CT0001
XB5 9001K 9001SK 9001KX
Family
XB4
UL File E78403. CCN NKCR Approvals UL Recognized File E164353. CCN NKCR2 CSA File LR44087. Class 3211-03 CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, EN/IEC 60947-5-5 EN/IEC 60204-1 and EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push buttons) Conforming to Standards EN/IEC 60364-5-53 (emergency switching of mechanical latching push buttons) JIS C 4520 UL 508 CSA C22.2 No.14 IP65 Degree of Protection IP66 for booted NEMA 1, 2, 3, 4, 12, 13 Electric Shock Protection Electrical Consumption 24 Vac/Vdc: 18 mA LED 120 Vac: 14 mA 240 Vac: 14 mA AC-15; B600 Ue = 600 Vac and le = 1.2 A Ue = 240 Vac and le = 3A Ue = 120 Vac and le = 6A Continuous 10 A DC-13; Q600 Ue = 600 Vdc and le = 0.1 A Ue = 250 Vdc and le = 0.27 A Ue = 125 Vdc and le = 0.55 A Connection Type 24 Vac/Vdc: 18 mA 120 Vac: 14 mA 240 Vac: 14 mA AC-15; B600 Ue = 600 Vac and le = 1.2 A Ue = 240 Vac and le = 3 A Ue = 120 Vac and le = 6 A Continuous 10 A DC-13; Q600 Ue = 600 Vdc and le = 0.1 A Ue = 250Vdc and le = 0.27 A Ue = 125 Vdc and le = 0.55 A Class I UL Recognized File E164353., CCN NKCR2 CSA File LR44087. Class 3211-03 CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, EN/IEC 60947-5-5 EN/IEC 60204-1 and EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push button). EN/IEC 60364-5-53 (emergency switching of mechanical latching push buttons) EN81-1 (emergency stop trigger action and mechanical latching push buttons with mechanical state indicator) JIS C 4520 UL 508 CSA C22.-2 No.14 IP65 IP66 for Booted NEMA 1, 2, 3, 4, 4X, 12, 13 Class I Class II JIS C 4520 and 852 UL 508 CSA C22.2 No.14 IP66 NEMA 1, 2, 3, 3R, 4, 12, 13 CSA File LR25490. Class 3211-03 CE Marked EN/IEC 60947-1
EN/IEC60947-5-1
EN/IEC60947-5-1
EN/IEC60947-5-4
EN/IEC60947-5-4
IP66
IP66
Class II
Class II
DC-13; Q600 Ue = 600 Vdc and le = 0.1 A Ue = 250 Vdc and le = 0.27 A Ue = 125 Vdc and le = 0.55 A
DC-13; Q600 Ue = 600 Vdc and le = 0.1 A Ue = 250 Vdc and le = 0.27 A Ue = 125 Vdc and le = 0.55 A Screw Terminal
DC-13; Q600 Ue = 600 Vdc and le = 0.1 A Ue = 250 Vdc and le = 0.27 A Ue = 125 Vdc and le = 0.55 A
Screw or Spring Terminal Screw Terminal: 1 x 24 AWG (0.22 mm) min. 2 x 14 AWG (2.5 mm) max. 2 x 16 AWG (1.5 mm) max. 19-23 Spring Terminal: 1 x 24 AWG (0.22 mm) min. 2 x 14 AWG (2.5 mm) max. 2 x 16 AWG (1.5 mm) max. 19-42 1 x 24 AWG (0.22 mm) min. 2 x 16 AWG (1.5 mm) max 19-63
19-3
19
Control Stations
Selection Guide
Refer to Catalog 9001CT0001
www.schneider-electric.us
Family
XAL
XAP
9001B
9001KY/SKY
Type KY3
XAPA1100
XALD02
XAPA1104
XAPAglass filled polyester XAPGdie cast zinc XAPEanodized aluminum 0 to 16 XB5 (22mm) Yes No UL File E164353 CCN NKCR CSA File LR 44087 Class 3211-03 CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, JIS C 4520 UL 508 CSA C22.2 No.14 XAPAundrilled XAPGTapped 3/4NPT XAPEflush mount (n/a) 19-96
NEMA 4 9001BW
9001BGplastic cover 9001BFstainless steel 9001BWdie cast zinc 9001BRcast aluminum 1 to 3 Built in No Yes UL File E78403 CCN NKCR CSA File LR 25490 Class 3211-03 CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, JIS C 4520 UL 508 CSA C22.2 No.14 9001BG1/2 &3/4 knockout 9001BFN/A 9001BW1/2-14NPT 9001BR1/2-14NPT 19-99
Type KZ31
KYAFsheet steel KYSSstainless steel KYdie cast zinc KZdie cast zinc SKYPlastic 1 to 6 9001K/SK (30mm) Yes Yes UL File E78403 CCN NKCR CSA File LR 25490 Class 3211-03 CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, JIS C 4520 UL 508 CSA C22.2 No.14 KYAF KYSSG conduit hub KY KZ1/2 & 3/4 knockout SKYG conduit hub 19-101
Type SKY2
Type of Product/Material
XALDPolycarbonate XALKPolycarbonate
Number of holes Type of Operators Available without Operators Available with Operators
1 to 3 XB5 (22mm) Yes Yes UL File E164353 CCN NKCR CSA File LR 44087 Class 3211-03 CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, JIS C 4520 UL 508 CSA C22.2 No.14
19
PUSH BUTTONS AND OPERATOR INTERFACE
Approvals
Conforming to Standards
Cable Entry
Digest Page
19-96
19-4
Pendant Stations
www.schneider-electric.us
Selection Guide
Refer to Catalog 9001CT0001
Family
9001BW
XACA2
XACA0
9001SKYP
2-Button Pendant 2
General Purpose Pendant 2, 3, 4, 6, 8, 12 UL File E164353 CNN NKCR CSA File LR 44087 Class 3211-03 EN/IEC 60947-5-1, EN/IEC 60204-32, EN/IEC 60947-5-5, and EN/ISO 13850 (for versions with trigger action emergency stop) UL 508 CSA C22-2 No. 14 NEMA 1, 4, 4X, 5 IP65 IK08 Yellow Polypropylene AC-15: A600 or Ue = 600V, le = 1.2A or Ue = 240V, le = 3A DC-13: Q600 or Ue = 600V. le = 0.1A or Ue = 250V, le = 0.27A Continuous 10A 826 mm cable entry screw clamp terminals
Heavy Duty Pendant 2, 4, 6, 8, 10 UL File E78403 CNN NKCR CSA File LR25490 Class 3211-03
Approvals
UL File E164353 CNN NKCR CSA File LR 44087 Class 3211-03 EN/IEC 60947-5-1, EN/IEC 60204-32, EN/IEC 60947-5-5, and EN/ISO 13850 (for versions with trigger action emergency stop) UL 508 CSA C22-2 No. 14 NEMA 1, 4, 4X, 5 IP65 IK08 Yellow Polypropylene AC-15: A600 or Ue = 600V, le = 1.2A or Ue = 240V, le = 3A DC-13: Q600 or Ue = 600V. le = 0.1A or Ue = 250V, le = 0.27A Continuous 10A 826 mm cable entry screw clamp terminals 1 x 0.5 mm (20AWG) min. 2 x 1.5 mm (16AWG) max. 1 x 2.5 mm (14AWG) max. 19-114
Conforming to Standards
CE Marked
CE Marked
Degree of Protection
NEMA 1, 3, 3R, 4, 4X
Housing Material
Yellow Polycarbonate SKRU2-SKRU5 AC - B300 DC - P600 SKRU1, 10, 11 AC - A600 DC - P600 NPT threaded conduit entry screw clamp terminals
Cable Size
Digest Page a
19-113
19-114
19-117
OSHA Section 1910.179, Overhead and Gantry Cranes, limits voltage at pendant push buttons to 150 Vac or 300 Vdc max.
19-5
19
Selection Guide
Refer to Catalog 9001CT0001
www.schneider-electric.us
XVE
Beacon 70mm Product for Customer Configuration UL File E164353 CCN NKCR
Tower Light 70 mm Product for Customer Configuration UL File E164353 CCN NKCR
Tower Light 50 mm Product for Customer Configuration UL File E164353 CCN NKCR
Tower Light and Beacon 70 mm Product for Customer Configuration UR CE Marked IEC/EN 60947-5-1 UL 508 CSA 22.2 No 14 IP42 LED / Incandescent
CSA File LR 44087 Class 3211 03 CE Marked IEC/EN 60947-5-1 UL 508 CSA 22.2 No 14 IP65 LED / Incandescent
CSA File LR 44087 Class 3211 03 CE Marked IEC/EN 60947-5-1 UL 508 CSA 22.2 No 14 IP65 LED / Incandescent
Conforming to Standards
19
Degree of Protection Light Source
Electrical Consumption LED Steady LED Flashing with Buzzer 24 Vac/dc: < 30 mA 120230 Vac: < 30 mA 24 Vac/dc: < 40 mA 120230 Vac: < 15mA 24 Vdc: 5 Joules unit < 430 mA; 10 J unit: < 850 mA Strobe (Energized) 120 Vac: 5 Joules unit: < 130 mA; 10 J unit: < 260 mA 230 Vac: 5 Joules unit: < 105 mA; 10 J unit: < 210 mA 1248 Vac/dc: < 20 mA Audible Sounders 120230 Vac: < 50 mA Connection Type Cable Size Digest Page Screw Clamp 1 x 16 AWG (1.5 mm) With Cable End 19-106 Screw Clamp 1 x 16 AWG (1.5 mm) With Cable End 19-107 24 Vac/dc: < 80 mA 120230 Vac: < 30mA 24 V ac/dc: < 40mA 120230 Vac: < 15 mA 24 Vdc: 40mA 120 Vac: 20mA 230 Vac: 11mA 24 Vdc: 15 mA 120 Vac: 15 mA 230 Vac: 12mA Screw Clamp 2 x 16 AWG (1.5 mm) With Cable End 19-110 24V ac/dc: < 25mA 120230 Vac: |< 25 mA 24 V ac/dc: < 30mA 120230Vac: < 25 mA 24 Vdc: 85 mA 120 Vac: 35 mA 230 Vac: 25 mA Screw Clamp 2 x 16 AWG (1.5 mm) With Cable End 19-109
19-6
Selection Guide
Refer to Catalog 9001CT0001
XVC 1 XVS XVR
Family
XVC 4
XVC 6
Tower Light 40 mm
Tower Light 60 mm
Siren and Electronic Alarm Adjustable Tones XVS14BMW, 0 to 105 decibels, 43 tones XVS72BM, 0 to 90 decibels, 16 tones
Features
All devices are pre-assembled and pre-wired. XVR12 S includes buzzer: 70 to 90 decibels UL Recognized E164353 CNN NKCR CSA LR44087 Class 3211-03 CE Marked EN61000-6-2 EN61000-6-4 UL 508 CSA 22.2 No. 14 IP23 / IP65 / IP66 LED
UL Recognized E164353 CNN NKCR Approvals CSA LR44087 Class 3211-03 CE Marked EN61000-6-2 Conforming to Standards EN61000-6-3 UL 508 CSA 22.2 No. 14 Degree of Protection Light Source Electrical Consumption 24 V: 1 unit = 40mA; 2 unit = 80mA; 3 unit = 120mA 4 unit = 160mA; 5 unit = 200mA **24 V: 1 unit = 90 mA; 2 unit = 130 mA; 3 unit = 170 mA 4 unit = 210 mA; 5 unit = 250 mA IP54 LED
UL Recognized E164353 CNN NKCR CSA LR44087 Class 3211-03 CE Marked EN61000-6-2 EN61000-6-3 EN61000-6-4 UL 508 CSA 22.2 No. 14 IP54 LED
UL Recognized E164353 CNN NKCR CSA LR44087 Class 3211-03 CE Marked EN61000-6-2 EN61000-6-3 EN61000-6-4 UL 508 CSA 22.2 No. 14 IP54 LED
UL Recognized E164353 CNN UCST CSA LR44087 Class 3211-03 CE Marked UL 508 CSA 22.2 No. 14 IP53 / IP54
LED Steady
24 V: 1 unit = 150mA; 2 unit = 250mA; 3 unit = 350mA 4 unit = 450mA; 5 unit = 550mA
Strobe (Energized)
XVS14BMW 12 Vdc: 350mA 24 Vdc: 400 mA XVS72BM 12 Vdc: 280 mA 24 Vdc: 190 mA XVS14BMW Pre-Wired, Color-Coded Wires cable length: 500mm XVS14 XVS72BM Not Pre-Wired 19-112
Audible Sounders Pre-Wired, Color-Coded Wires cable length: 600mm XVC4B* 900mm XVC4B*K 500mm XVC4B*5S Pre-Wired, Color-Coded Wires cable length: 600mm XVC6B* 850mm XVC6B*K 550mm XVC6B*5S 850mm XVC6B*5SK 22 AWG (0.33 mm) 19-105 Pre-Wired, Color-Coded Wires cable length: 500mm XVC1B*K 500mm XVC1B*SK 550mm XVC6B*5S 850mm XVC6B*5SK 22 AWG (0.33 mm) 19-105
Pre-Wired cable length: 500mm XVR08* 400mm XVR10* 400mm XVR12* 400mm XVR13*
Connection Type
Cable Size Digest Page 2009 Schneider Electric All Rights Reserved
19-7
19
24 V: 1 unit = 100mA; 2 unit = 200mA; 3 unit = 300mA 4 unit = 400mA; 5 unit = 500mA
XVR08, XVR10, XVR12, and XVR13 (without buzzer) 12 Vac/dc: 360mA 24 Vac/dc: 180mA
22 mm Push Buttons
Table 19.1:
Operator Style XB4 Die Cast Chrome
Table 19.5:
Operator Style XB4 Die Cast Chrome
Description
Description
XB4BA21 1 N.O.
38.50 ZBY2303
3.40
XB4BL42 1 N.C.
38.50 ZBY2304
3.40
XB5AA21
38.50 ZBY2303
3.40
XB5AL42
38.50 ZBY2304
3.40
Table 19.2:
Operator Style
Table 19.6:
Operator Style
Description
Description
XB4BD21 1 N.O.
51.00 ZBY2367
3.40
XB4BD33 2 N.O.
68.00 ZBY2387
3.40
XB5AD21
51.00 ZBY2367
3.40
XB5AD33
68.00 ZBY2387
3.40
Table 19.3:
Operator Style
Table 19.7:
Operator Style XB4 Die Cast Chrome
Description
Description
72.00 ZBY2311
3.40
XB4BVG3
72.00 ZBY2312
3.40
19
PUSH BUTTONS AND OPERATOR INTERFACE
72.00 ZBY2311
3.40
XB5AVG3
72.00 ZBY2312
3.40
Table 19.4:
Operator Style XB4 Die Cast Chrome
Table 19.8:
Description
Operator Style
Description
XB4BT42 1 N.C.
68.00 ZBY9330
3.40 XB4 Die Cast Chrome 1 N.O. / 1 N.C. XB4BS8445 165.00 ZBY9330 3.40
XB5AT42
68.00 ZBY9330
3.40 XB5 Double Insulated 1 N.O./ 1 N.C. XB5AS8445 165.00 ZBY9330 3.40
19-8
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.9:
Table 19.13:
KR1BH13
89.
KN201
4.40
KR1RH13
89.
KN202
4.40
SKR1BH13
89. KN101SP
4.40
SKR1RH13
89. KN102RP
4.40
Table 19.10:
Table 19.14:
KS11BH13
106.
KN244
2.90
30 mm Industrial (Metal) 1 0 0 0 0 1
KS43BH13
106.
KN260
4.40
SKS11BH13
106. KN144SP
2.90
4.40
Table 19.11:
Operator Style 30 mm Industrial (Metal)
Table 19.15:
Operator Style 30 mm Industrial (Metal)
Description
KP1R31
153.
KN203
4.40
KP1G31
153.
KN204
4.40
KT1G31
197.
KN204
4.40
KT1R31
197.
KN203
4.40
SKT1R31
197. KN103SP
4.40
SKT1G31
197. KN104RP
4.40
CP1
Discount Schedule
19-9
19
SKP1R31
153. KN103SP
4.40
SKP1G31
153.
KN104SP
4.40
Style/Voltage Transformer, 110120 V, 5060 Hz Incandescent, 120 Vac/Vdc Incandescent, 2428 Vac/Vdc LED, 2428 Vac LED, 2428 Vdc LED, 120 Vac Red Replacement LED, Yellow 120 Vac Green
Table 19.18:
Style/Voltage
Transformer, 110120 V, 5060 Hz Incandescent, 120 Vac/Vdc Incandescent, 24-28 Vac/Vdc LED, 2428 Vac LED, 2428 Vdc LED, 120 Vac Red Replacement LED, Yellow 120 Vac Green
Table 19.19:
Color Red Green Amber Blue White Yellow
19
PUSH BUTTONS AND OPERATOR INTERFACE
a b
9.90
Table 19.20:
Legend Plates
Description Blank Special Marking (Specify Marking) Blank Special Marking (Specify Marking) Black Field Red Field Black Field Red Field Aluminum Field Aluminum Field 2 16 2 8 Maximum Number of Lines Maximum Number of Characters Catalog Numberb JN100 JN100R JN199 JN199R JN700 JN799 $ Price 4.40
Other voltages are available. Refer to Catalog 9001CT0001. To order, add prefix 9001 to the beginning of the catalog number.
19-10
CP1
Discount Schedule
28.70
Type O
Table 19.22:
XVLA1
Cabling
Table 19.24:
XVLA2
8 mm a with integral ballast resistor and reverse polarity protection diode Degree of protection IP40 LED pilot lights 8 mm, with black bezel, visible LED XVLA1
32.80
Table 19.25:
XVLA3
8 mma with integral ballast resistor and reverse polarity protection diode Degree of protection IP40 8 mm, with lens incorporated, LED XVLA2 12 mm b with integral ballast resistor and reverse polarity protection diode Degree of protection IP40 12 mm, with lens incorporated, LED XVLA3 a b Quick connects (2.8 x 0.5 mm). Screw termination.
32.80
24 V
12 V
52.00
24 V
Table 19.26:
XVLX
Accessories
Tightening tools (Sold singly) Description For 8 mm pilot lights For 12 mm pilot lights For 8 mm pilot lights For 12 mm pilot lights Catalog Number XVLX08 XVLX12 XVLZ911 XVLZ912 $ Price Each 18.60 24.00 0.65
CP1
Discount Schedule
19-11
19
XVLZ91
16 mm Push Buttons
Table 19.27:
Illuminated Push Buttons (1224 Vac/Vdc LED included) Complete Units with Quick Connectors/Solder Tabs
Type of Contact N.O. N.C.
Type of Operator
Color Rectangular
$ Price
XB6DWB
XB6CEB
XB6AFB
Square Round Catalog Number White XB6DW1B1B XB6CW1B1B XB6AW1B1B Green XB6DW3B1B XB6CW3B1B XB6AW3B1B 1 Yellow XB6DW5B1B XB6CW5B1B XB6AW5B1B Blue XB6DW6B1B XB6CW6B1B XB6AW6B1B 1 Red XB6DW4B2B XB6CW4B2B XB6AW4B2B Flush, spring return White XB6DW1B5B XB6CW1B5B XB6AW1B5B Green XB6DW3B5B XB6CW3B5B XB6AW3B5B 1 1 Red XB6DW4B5B XB6CW4B5B XB6AW4B5B Yellow XB6DW5B5B XB6CW5B5B XB6AW5B5B Blue XB6DW6B5B XB6CW6B5B XB6AW6B5B White XB6DF1B1B XB6CF1B1B XB6AF1B1B Green XB6DF3B1B XB6CF3B1B XB6AF3B1B 1 Yellow XB6DF5B1B XB6CF5B1B XB6AF5B1B Blue XB6DF6B1B XB6CF6B1B XB6AF6B1B 1 Red XB6DF4B2B XB6CF4B2B XB6AF4B2B Flush, maintained White XB6DF1B5B XB6CF1B5B XB6AF1B5B Green XB6DF3B5B XB6CF3B5B XB6AF3B5B 1 1 Red XB6DF4B5B XB6CF4B5B XB6AF4B5B Yellow XB6DF5B5B XB6CF5B5B XB6AF5B5B Blue XB6DF6B5B XB6CF6B5B XB6AF6B5B White XB6DE1B1B XB6CE1B1B XB6AE1B1B Green XB6DE3B1B XB6CE3B1B XB6AE3B1B 1 Yellow XB6DE5B1B XB6CE5B1B XB6AE5B1B Blue XB6DE6B1B XB6CE6B1B XB6AE6B1B 1 Red XB6DE4B2B XB6CE4B2B XB6AE4B2B Extended, spring return White XB6DE1B5B XB6CE1B5B XB6AE1B5B Green XB6DE3B5B XB6CE3B5B XB6AE3B5B 1 1 Red XB6DE4B5B XB6CE4B5B XB6AE4B5B Yellow XB6DE5B5B XB6CE5B5B XB6AE5B5B Blue XB6DE6B5B XB6CE6B5B XB6AE6B5B Note: Illuminated Push Buttons 120 Vac LED are available as Complete Units with Quick Connectors/Solder Tabs. Use 1224 V table above. Change Voltage Code (2nd B) to G. Example: XB6DW1B1B (White 24 V, 1 N.O.) becomes XB6DW1G1B.
44.40 44.40
52.00
44.40 44.40
52.00
44.40 44.40
52.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
19-12
Discount Schedule
16 mm Push Buttons
www.schneider-electric.us
Table 19.28:
Pilot Lights (1224 Vac/Vdc LED included) Complete Units with Quick Connectors/Solder Tabs
Color
$ Price Rectangular Square Catalog Number XB6CV1BB XB6CV3BB XB6CV4BB XB6CV5BB XB6CV6BB Round XB6AV1BB XB6AV3BB XB6AV4BB XB6AV5BB XB6AV6BB
XB6DVB
White Green Red Yellow Blue
27.30
XB6CVB
Table 19.29:
Pilot Lights (120 Vac LED) Complete Units with Quick Connectors/Solder Tabs
Color
$ Price
XB6AVB
White Green Red Yellow Blue
27.30
Table 19.30:
Type of Push
Color
Rectangular
Square Catalog Number XB6CA11B XB6CA21B XB6CA31B XB6CA51B XB6CA61B XB6CA22B XB6CA42B XB6CA15B XB6CA25B XB6CA35B XB6CA45B XB6CA55B XB6CA65B
Round XB6AA11B XB6AA21B XB6AA31B XB6AA51B XB6AA61B XB6AA22B XB6AA42B XB6AA15B XB6AA25B XB6AA35B XB6AA45B XB6AA55B XB6AA65B
$ Price
XB6DAB
26.20
26.20
XB6CAB
1 1
34.10
Table 19.31:
XB6AAB
Shape of Head
Trigger Action Emergency Stop Mushroom Head Push Buttons (Color Red)a
Type of Push Type of Contact N.O. Turn-to-release 1 1 30 XB6AS8345B 73.00 N.C. 1 Diameter of Head (mm) 30 Catalog Number $ Price
XB6AS8342B
65.00
Key release
30
XB6AS9342B
78.00
XB6AS9345B
a
30
XB6AS9345B
87.00
Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator.
Table 19.32:
Circular Legends, 45 mm
Color Yellow Text Blank Emergency stop Catalog Number ZB6Y7001 ZB6Y7330 $ Price 3.40
ZB6Y7330
Discount Schedule
19-13
19
XB6AS8345B
16 mm Push Buttons
Table 19.33:
Selector Switches (Switching Angle: Handle: 60 , Key: 70 ) Complete Units with Quick Connectors/Solder Tabs
Number and Type of Positions
Type of Operator
Type of Contact
XB6DDB
N.O. 1
XB6AD221B
29.70
XB6DD225B
XB6CD225B
XB6AD225B
37.60
XB6DD235B
XB6CD235B
XB6AD235B
37.60
XB6CDB
2 3-maintained XB6DD233B XB6CD233B XB6AD233B 37.60
Type of Operator
Rectangular
Round
$ Price
XB6ADB
1 Key 1
2-maintained
XB6DGC5B
XB6CGC5B
XB6AGC5B
68.00
2-maintained
XB6DGB5B
XB6CGB5B
XB6AGB5B
68.00
3-maintained
XB6DGH5B
XB6CGH5B
XB6AGH5B
68.00
2 Note:
3-maintained
XB6DGH3B
XB6CGH3B
XB6AGH3B
68.00
XB6DGB
Table 19.34:
19
XB6CGB
O X O X X O X O
XB6AGB
1 N.O. (left) 2 N.O. wired in parallel (side by side) 1 N.O. (right) 1 N.C. (right) 1 N.C. (left) 2 N.C. wired in series (side by side)
19-14
Discount Schedule
16 mm Push Buttons
www.schneider-electric.us
Table 19.35:
Description
Quick connectors/solder tabs 1 1 White Green Yellow Blue Red Yellow White Green Red Yellow Blue White Green Yellow Blue Red Yellow White Green Red Yellow Blue ZB6ZB11B ZB6ZB31B ZB6ZB51B ZB6ZB61B ZB6ZB42B ZB6ZB52B ZB6ZB15B ZB6ZB35B ZB6ZB45B ZB6ZB55B ZB6ZB65B ZB6ZG11B ZB6ZG31B ZB6ZG51B ZB6ZG61B ZB6ZG42B ZB6ZG52B ZB6ZG15B ZB6ZG35B ZB6ZG45B ZB6ZG55B ZB6ZG65B ZB6ZH01B ZB6ZH02B ZB6ZH05B 28.00 28.00
ZB6ZBB
1224 Vac/Vdc
1 Integral LED b 1
35.20
28.00 28.00
ZB6ZHB
120 Vac
1 1 1
1 1 1
< 24 Vac/Vdc
Table 19.36:
Description
Quick connectors/solder tabs ZB6Z1B ZB6Z2B ZB6Z3B ZB6Z4B ZB6Z5B 9.40 9.40 16.60 16.60 16.60
ZB6ZB
Table 19.37:
Description
1224 Vac/Vdc
16.60
ZB6EB
Integral LEDc 120 Vac
16.60
ZB6E0B
Table 19.38:
Contact Material
ZB6EB
Type of Contact Catalog Number $ Price N.O. N.C. 1 ZB6E1B 7.20 Silver alloy Quick connectors/solder tabs 1 ZB6E2B 7.20 1 ZB6E1E 12.40 Gold flashed Quick connectors/solder tabs 1 ZB6E2E 12.40 a Illuminated selector switches can be assembled by using a contact block/light module assembly in conjunction with a selector switch head, supplied without handle, and a transparent handle. See page 19-16. b The LED must be the same color as the push button cap. c The LED must be the same color as the lens. d Order bulbs separately. See page 19-22. e Neon bulb can only be used with a red, yellow, or white cap. f Electrical components with connection by printed circuit board pins are available. Refer to Catalog 9001CT0001 for details.
Discount Schedule
19-15
19
16 mm Push Buttons
Table 19.39:
Heads for Illuminated Push Buttons (To combine with complete bodies and contact blocks, see page 19-15)
Type of Push
Color Rectangular Round ZB6AW1 ZB6AW3 ZB6AW4 ZB6AW5 ZB6AW6 ZB6AW9 ZB6AF1 ZB6AF3 ZB6AF4 ZB6AF5 ZB6AF6 ZB6AF9 ZB6AE1 ZB6AE3 ZB6AE4 ZB6AE5 ZB6AE6 ZB6AE9
$ Price
ZB6DW
ZB6CE
ZB6AF
a
Square Catalog Number White ZB6DW1 ZB6CW1 Green ZB6DW3 ZB6CW3 Red ZB6DW4 ZB6CW4 Flush, spring return Yellow ZB6DW5 ZB6CW5 Blue ZB6DW6 ZB6CW6 5 colors a ZB6DW9 ZB6CW9 White ZB6DF1 ZB6CF1 Green ZB6DF3 ZB6CF3 Red ZB6DF4 ZB6CF4 Flush, maintained Yellow ZB6DF5 ZB6CF5 Blue ZB6DF6 ZB6CF6 5 colors a ZB6DF9 ZB6CF9 White ZB6DE1 ZB6CE1 Green ZB6DE3 ZB6CE3 Red ZB6DE4 ZB6CE4 Extended, spring return Yellow ZB6DE5 ZB6CE5 Blue ZB6DE6 ZB6CE6 5 colorsa ZB6DE9 ZB6CE9 Five different color caps included with head (white, green, red, yellow, and blue).
14.40
16.40
14.40
16.40
14.40
16.40
Table 19.40:
Heads for Pilot Lights (To combine with light modules, see page 19-15.)
ZB6DV
Color Square Catalog Number White ZB6DV1 ZB6CV1 Green ZB6DV3 ZB6CV3 Red ZB6DV4 ZB6CV4 Yellow ZB6DV5 ZB6CV5 Blue ZB6DV6 ZB6CV6 5 colors b ZB6DV9 ZB6CV9 Five different color caps included with head (white, green, red, yellow, and blue). Rectangular Round ZB6AV1 ZB6AV3 ZB6AV4 ZB6AV5 ZB6AV6 ZB6AV9
$ Price
8.20
ZB6CV
b
10.20
19
PUSH BUTTONS AND OPERATOR INTERFACE ZB6AV
19-16
Discount Schedule
16 mm Push Buttons
www.schneider-electric.us
Non-Illuminated Operators
Table 19.41: Heads for Push Buttons (To combine with complete bodies and contact blocks, see page 19-15.)
Type of Push
Color
Rectangular
Round
$ Price
ZB6DA
White Black Green Flush, spring return Red Yellow Blue 6 colorsa a ZB6DA1 ZB6DA2 ZB6DA3 ZB6DA4 ZB6DA5 ZB6DA6 ZB6DA9
ZB6CA
Five different color caps included with head (white, green, red, yellow, and blue).
ZB6AA
Table 19.42:
Shape of Head
Turn-to-release
Red
ZB6AS834
49.60
ZB6AS834
Table 19.43:
Description
Circular Legends, 45 mm
Color Yellow Emergency stop ZB6Y7330 Text Blank Catalog Number ZB6Y7001 3.40 $ Price
Circular legends, 45 mm b
Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator.
ZB6Y7330
Switching angle: maintained positions 60, spring return positions 45 2-maintained Black ZB6DD22 ZB6CD22 ZB6AD22
ZB6DD
2-maintained 3-maintained
Black Black
ZB6DD28b ZB6DD23
ZB6CD28b ZB6CD23
ZB6AD28b ZB6AD23
Black
ZB6DD24
ZB6CD24
ZB6AD24
17.60
ZB6CD
Black
ZB6DD25
ZB6CD25
ZB6AD25
Black
ZB6DD26
ZB6CD26
ZB6AD26
Black
ZB6DD27
ZB6CD27
ZB6AD27
For bodies with 2 contact blocks, maximum. Switching angle: maintained positions 90o. See selector switch sequence charts on page 19-19.
ZB6AD
Legends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19-20 and 19-22
Discount Schedule
19-17
19
16 mm Push Buttons
Table 19.45:
Heads for Non-Illuminated Selector Switchesac (To combine with complete bodies and contact blocks, see page 19-15.)
Color of Handle
Switching angle: maintained positions 60, spring return positions 45 2-maintained Black ZB6DD22 ZB6CD22 ZB6AD22
ZB6DD
2-maintained Black ZB6DD28b ZB6CD28b ZB6AD28b
3-maintained
Black
ZB6DD23
ZB6CD23
ZB6AD23
Black
ZB6DD24
ZB6CD24
ZB6AD24
17.60
ZB6CD
Black
ZB6DD25
ZB6CD25
ZB6AD25
Black
ZB6DD26
ZB6CD26
ZB6AD26
Black
ZB6DD27
ZB6CD27
ZB6AD27
ZB6AD
For bodies with 2 contact blocks, maximum. Switching angle: maintained positions 90o. See selector switch sequence charts on page 19-14.
19
PUSH BUTTONS AND OPERATOR INTERFACE
19-18
Discount Schedule
16 mm Push Buttons
www.schneider-electric.us
Table 19.46:
Heads for Ronis Key Operated Selector Switches a (To combine with complete bodies and contact blocks, see page 19-15.)
$ Price
Switching angle: maintained positions 70o, spring return positions 45o Right-hand position ZB6DGA ZB6CGA ZB6AGA
2-maintained
Center position
ZB6DGB
ZB6CGB
ZB6AGB
Both positions
ZB6DGC
ZB6CGC
ZB6AGC
ZB6DG
Center position Left-hand position Center position Left-hand and center positions
ZB6DGL ZB6DGD ZB6DGE ZB6DGF ZB6DGG ZB6DGH ZB6DGJ ZB6DGK ZB6DGQ ZB6DGR
ZB6CGL ZB6CGD ZB6CGE ZB6CGF ZB6CGG ZB6CGH ZB6CGJ ZB6CGK ZB6CGQ ZB6CGR
ZB6AGL ZB6AGD ZB6AGE ZB6AGF ZB6AGG ZB6AGH ZB6AGJ ZB6AGK ZB6AGQ ZB6AGR 45.60
3-maintained
ZB6CG
Left-hand and right-hand positions Right-hand and center positions Left-hand position Center position
ZB6DGS
ZB6CGS
ZB6AGS
Center position
ZB6DGT
ZB6CGT
ZB6AGT
ZB6AG
Table 19.47:
O X O X
X O X O
1 N.O. (left or right) 1 N.C. (left or right) 1 N.O. and 1 N.C. 3 Position Selector Switch Contact block guide b
1 N.O. (left) 2 N.O. wired in parallel (side by side) 1 N.O. (right) 1 N.C. (right) 1 N.C. (left) 2 N.C. wired in series (side by side)
Discount Schedule
19-19
19
Note: Indicates key withdrawal position. a Ronis 200 key standard. Other keys available, refer to Catalog 9001CT0001.
16 mm Push Buttons
XB6 Accessories
Refer to Catalog 9001CT0001
www.schneider-electric.us
Table 19.48:
ZB6YD20
Table 19.49:
Color
ZB6Y2178
STO
ZB6Y2304
Marking Catalog Number O-I ZB6Y2178 I-II ZB6Y2179 International I-O-II ZB6Y2186 O ZB6Y2190 HAND-O-AUTO ZB6Y2387 CLOSE ZB6Y2314 DOWN ZB6Y2308 FORWARD ZB6Y2305 FAULT ZB6Y2334 White Text Red Background (Stop and Fault) LEFT ZB6Y2310 Black Background (all others) OFF ZB6Y2312 English ON ZB6Y2303 OPEN ZB6Y2313 RESET ZB6Y2323 REVERSE ZB6Y2306 RIGHT ZB6Y2309 RUN ZB6Y2311 STOP ZB6Y2304 UP ZB6Y2307 a Additional legend plate sizes and markings are available in Catalog 9001CT0001.
1.60
19
PUSH BUTTONS AND OPERATOR INTERFACE
19-20
Discount Schedule
16 mm Push Buttons
www.schneider-electric.us
XB6 Accessories
Refer to Catalog 9001CT0001
Table 19.50:
Ink Marking Color: White on colored cap Black on white cap For non-illuminated push buttons 0
Color Rectangular Square Catalog Number ZB6YC100 ZB6YC200 ZB6YC101 ZB6YC201 ZB6YC102 ZB6YC202 ZB6YC103 ZB6YC203 ZB6YC104 ZB6YC204 ZB6YC105 ZB6YC205 ZB6YC106 ZB6YC206 ZB6YC107 ZB6YC207 ZB6YC108 ZB6YC208 ZB6YC109 ZB6YC209 ZB6YC117 ZB6YC317 ZB6YC224 ZB6YC424 ZB6YC111 ZB6YC311 ZB6YC210 ZB6YC410 ZB6YC226 ZB6YC626 ZB6YC140 ZB6YC340 ZB6YC241 ZB6YC441 ZB6YC112 ZB6YC212 ZB6YC113 ZB6YC213 ZB6YC114 ZB6YC214 ZB6YC115 ZB6YC215 ZB6YC127 ZB6YC227 ZB6YC128 ZB6YC228 ZB6YC132 ZB6YC232 ZB6YC119 ZB6YC219 ZB6YC120 ZB6YC220 ZB6YC121 ZB6YC221 ZB6YC122 ZB6YC222 Round
$ Price
ZB6YD10
1 2 3 4
ZB6YC10
5 6 7 8
ZB6YA10
9 ON OFF
ZB6YD17
I O R START
ZB6YD19
STOP II III +
UP DOWN
ZB6YA19
CLOSE
Discount Schedule
19-21
19
ZB6YC19
White Black White Black White Black White Black White Black White Black White Black White Black White Black White Black White Green Black Red White Green Black Red Black Blue White Green Black Red White Black White Black White Black White Black White Black White Black White Black White Black White Black White Black White Black
ZB6YD100 ZB6YD200 ZB6YD101 ZB6YD201 ZB6YD102 ZB6YD202 ZB6YD103 ZB6YD203 ZB6YD104 ZB6YD204 ZB6YD105 ZB6YD205 ZB6YD106 ZB6YD206 ZB6YD107 ZB6YD207 ZB6YD108 ZB6YD208 ZB6YD109 ZB6YD209 ZB6YD117 ZB6YD317 ZB6YD224 ZB6YD424 ZB6YD111 ZB6YD311 ZB6YD210 ZB6YD410 ZB6YD226 ZB6YD626 ZB6YD140 ZB6YD340 ZB6YD241 ZB6YD441 ZB6YD112 ZB6YD212 ZB6YD113 ZB6YD213 ZB6YD114 ZB6YD214 ZB6YD115 ZB6YD215 ZB6YD127 ZB6YD227 ZB6YD128 ZB6YD228 ZB6YD132 ZB6YD232 ZB6YD119 ZB6YD219 ZB6YD120 ZB6YD220 ZB6YD121 ZB6YD221 ZB6YD122 ZB6YD222
ZB6YA100 ZB6YA200 ZB6YA101 ZB6YA201 ZB6YA102 ZB6YA202 ZB6YA103 ZB6YA203 ZB6YA104 ZB6YA204 ZB6YA105 ZB6YA205 ZB6YA106 ZB6YA206 ZB6YA107 ZB6YA207 ZB6YA108 ZB6YA208 ZB6YA109 ZB6YA209 ZB6YA117 ZB6YA317 ZB6YA224 ZB6YA424 ZB6YA111 ZB6YA311 ZB6YA210 ZB6YA410 ZB6YA226 ZB6YA626 ZB6YA140 ZB6YA340 ZB6YA241 ZB6YA441 ZB6YA112 ZB6YA212 ZB6YA113 ZB6YA213 ZB6YA114 ZB6YA214 ZB6YA115 ZB6YA215 ZB6YA127 ZB6YA227 ZB6YA128 ZB6YA228 ZB6YA132 ZB6YA232 ZB6YA119 ZB6YA219 ZB6YA120 ZB6YA220 ZB6YA121 ZB6YA221 ZB6YA122 ZB6YA222
4.20
16 mm Push Buttons
XB6 Accessories
Refer to Catalog 9001CT0001
www.schneider-electric.us
Table 19.51:
Description Body
Accessories
Application Fitting contact blocks Fixing the switch and changing bulbs Fixing head to panel Flush mounting a circular head push button or pilot light in 22 mm cut-out Protecting contacts against touching Circular and square head push buttons and switches Rectangular head push buttons and switches Catalog Number ZB6Y009 ZB6Y905 ZB6Y019 ZB6Y002 ZB6YA002 ZB6Y001 ZB6YA001 ZB6YD001 ZB6Y004 ZB6Y005 ZB6Y007 ZB6YA006 ZB6YJ012 ZB6YB028 ZB6YG095 $ Price 2.00 4.20 12.40 2.00 6.20 3.40 16.60 16.60 0.42 4.20 6.20 2.00 2.00 2.00 4.20
ZB6Y002 ZB6Y009
Protective cover
Sold in lots of 100 pieces Plugging an unused knockout Key operated selector switches and emergency stop mushroom 6V
ZB6Y905
Blanking plug Ronis key, 2 pieces
12 V 28 Va
110/230 V b
Table 19.52:
ZB6YA001
ZB6YD001
ZB6YD20
Table 19.53:
Color
ZB6Y2178
P STO
ZB6Y2304
Marking Catalog Number O-I ZB6Y2178 I-II ZB6Y2179 International I-O-II ZB6Y2186 O ZB6Y2190 HAND-O-AUTO ZB6Y2387 CLOSE ZB6Y2314 DOWN ZB6Y2308 FORWARD ZB6Y2305 FAULT ZB6Y2334 White Text Red Background (Stop and Fault) LEFT ZB6Y2310 Black Background (all others) OFF ZB6Y2312 English ON ZB6Y2303 OPEN ZB6Y2313 RESET ZB6Y2323 REVERSE ZB6Y2306 RIGHT ZB6Y2309 RUN ZB6Y2311 STOP ZB6Y2304 UP ZB6Y2307 a Additional legend plate sizes and markings are available in Catalog 9001CT0001.
19
PUSH BUTTONS AND OPERATOR INTERFACE
1.60
Table 19.54:
Description
Circular Legends, 45 mm
Color Yellow Text Blank Emergency stop Catalog Number ZB6Y7001 ZB6Y7330 $ Price 3.40
ZB6Y7330
Circular legends, 45 mm
19-22
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.55:
Shape of Head
38.50 38.50
XB4BA31
Flush
56.00
XB4BA4322
Flush
I (white)
44.70
Flush
O (white)
(ZB4BZ102 + ZB4BA432) (ZB4BZ101 + ZB4BP2) (ZB4BZ101 + ZB4BP3) (ZB4BZ101 + ZB4BP5) (ZB4BZ101 + ZB4BP6) (ZB4BZ102 + ZB4BP4) (ZB4BZ102 + ZB4BL4) (ZB4BZ105 + ZB4BL4)
44.70
XB4BP51
1 1 1
Extended
Mushroom head 40 mm
Black
XB4BC21
(ZB4BZ101 + ZB4BC2)
56.00
XB4BL42
Table 19.56:
Shape of Head
XB4BC21
One flush green push (marked I) One extended red push (marked O)
IP40
XB4BL845
(ZB4BZ105 + ZB4BL8434)
69.00
XB4BL845
Discount Schedule
19-23
19
22 mm Push Buttons
Table 19.57:
Shape of Head
Non-Illuminated Emergency Stop and Emergency Off Mushroom Head Push Buttons, 40 mm, Red (screw clamp terminal connections)
Type of Push Type of Contact N.O. N.C. Catalog Number (Components) $ Price
XB4BT845
(ZB4BZ105 + ZB4BT84)
101.00
XB4BT845
Trigger action turn-to-releasea 1 1 1 2 XB4BS8445 XB4BS84441 (ZB4BZ105 + ZB4BS844) 165.00 (ZB4BZ141 + ZB4BS844)
XB4BS9445
(ZB4BZ105 + ZB4BS944)
165.00
XB4BS9445
Push-pull 1 XB4BT42 (ZB4BZ102 + ZB4BT4) 68.00
Turn-to-release
XB4BS542
(ZB4BZ102 + ZB4BS54)
110.00
XB4BS542
a
XB4BS142
(ZB4BZ102 + ZB4BS14)
147.00
Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator. For emergency stop applications, always use a trigger action push button (per EN/IEC 13850).
Table 19.58:
Shape of Head
Non-Illuminated Selector Switches and Key Switches (screw clamp terminal connections)b
Type of Operator Type of Contact N.O. 1 1 N.C. 1 Number and Type of Positions 2-maintained 2-maintained 3-maintained Catalog Number (Components) XB4BD21 XB4BD25 XB4BD33 XB4BD53 XB4BJ21 XB4BJ33 XB4BJ53 XB4BG21 2-maintained 1 2-momentary to left XB4BG41 XB4BG61 XB4BG03 2 3-maintained XB4BG33 (ZB4BZ103 + ZB4BG3) 141.00 (ZB4BZ101 + ZB4BG4) (ZB4BZ101 + ZB4BG6) (ZB4BZ103 + ZB4BG0) 123.00 123.00 141.00 (ZB4BZ101 + ZB4BD2) (ZB4BZ105 + ZB4BD2) (ZB4BZ103 + ZB4BD3) (ZB4BZ103 + ZB4BD5) (ZB4BZ101 + ZB4BJ2) (ZB4BZ103 + ZB4BJ3) (ZB4BZ103 + ZB4BJ5) (ZB4BZ101 + ZB4BG2) $ Price 51.00 68.00 68.00 75.00 51.00 68.00 75.00 123.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
XB4BD33
3-momentary to center
2-maintained 3-maintained
3-momentary to center
XB4BJ33
XB4BG33
Note: The symbol indicates key withdrawal position(s). b See page 19-29 for contact configurations.
19-24
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.59:
Shape of Head
24 Vac/Vdc
72.00
XB4BVB5
110120 Vac
72.00
Table 19.60:
Shape of Head
XB4BV64
Direct supply, for BA9s (incandescent, LED, neon) V < 250 V, 2.4 W bulb (bulb not included) White XB4BV61 Green XB4BV63 < 250 Vac/Vdc Red XB4BV64 Yellow XB4BV65 Transformer type with 1.2 VA, 6 V secondary. BA9s incandescent bulb included White XB4BV31 Green XB4BV33 110120 Vac 50/60 Hz Red XB4BV34 Yellow XB4BV35
51.00
117.00
XB4BV33
Table 19.61:
Shape of Head Flush
24 Vac/Vdc
XB4BW33B5
1 110120 Vac
XB4BW3465
Transformer type 1.2 VA, 6 V secondary. BA9s incandescent bulb included
White Green Red Yellow Blue White Green Red Yellow Blue White Green Red Yellow White Green Red Yellow White Green Red Yellow
XB4BW31B5 XB4BW33B5 XB4BW34B5 XB4BW35B5 XB4BW36B5 XB4BW31G5 XB4BW33G5 XB4BW34G5 XB4BW35G5 XB4BW36G5 XB4BW3165 XB4BW3365 XB4BW3465 XB4BW3565 XB4BW3135 XB4BW3335 XB4BW3435 XB4BW3535 XB4BW3145 XB4BW3345 XB4BW3445 XB4BW3545
(ZB4BW0B15 + ZB4BW313) (ZB4BW0B35 + ZB4BW333) (ZB4BW0B45 + ZB4BW343) (ZB4BW0B55 + ZB4BW353) (ZB4BW0B65 + ZB4BW363) (ZB4BW0G15 + ZB4BW313) (ZB4BW0G35 + ZB4BW333) (ZB4BW0G45 + ZB4BW343) (ZB4BW0G55 + ZB4BW353) (ZB4BW0G65 + ZB4BW363) (ZB4BW065 + ZB4BW31) (ZB4BW065 + ZB4BW33) (ZB4BW065 + ZB4BW34) (ZB4BW065 + ZB4BW35) (ZB4BW035 + ZB4BW31) (ZB4BW035 + ZB4BW33) (ZB4BW035 + ZB4BW34) (ZB4BW035 + ZB4BW35) (ZB4BW045 + ZB4BW31) (ZB4BW045 + ZB4BW33) (ZB4BW045 + ZB4BW34) (ZB4BW045 + ZB4BW35)
119.00
119.00
99.00
163.00
163.00
Extended
Discount Schedule
19-25
19
XB4BW3545
White XB4BW11B5 (ZB4BW0B15 + ZB4BW113) Green XB4BW13B5 (ZB4BW0B35 + ZB4BW133) 24 Vac/Vdc Red XB4BW14B5 (ZB4BW0B45 + ZB4BW143) 113.00 Yellow XB4BW15B5 (ZB4BW0B55 + ZB4BW153) Blue XB4BW16B5 (ZB4BW0B65 + ZB4BW163) 1 1 White XB4BW11G5 (ZB4BW0G15 + ZB4BW113) Green XB4BW13G5 (ZB4BW0G35 + ZB4BW133) 110120 Vac Red XB4BW14G5 (ZB4BW0G45 + ZB4BW143) 113.00 Yellow XB4BW15G5 (ZB4BW0G55 + ZB4BW153) Blue XB4BW16G5 (ZB4BW0G65 + ZB4BW163) For 240 V LED, replace the last B or G in the catalog number with an M. For example, XB4BVB1 (24 V) becomes XB4BVM1 (240 VAC only).
22 mm Push Buttons
XB4 Operators
Refer to Catalog 9001CT0001
www.schneider-electric.us
Table 19.62:
Shape of Head
ZB4BA0
11.00
ZB4BA0
Flush, with set of 6 color caps
ZB4BA4
Flush
ZB4BA38
ZB4BP18
Extended
ZB4BL1
Guarded Head
White Black Green Red Yellow Blue White Black Green Red Yellow Blue Gray White Green Red Yellow Blue White Black Green Red Yellow Blue White Green Red Yellow Blue White Black Green Red Yellow Blue White Black Green Red Yellow Blue
ZB4BA9
13.00
ZB4BA1 ZB4BA2 ZB4BA3 ZB4BA4 ZB4BA5 ZB4BA6 ZB4BA8 ZB4BA18 ZB4BA38 ZB4BA48 ZB4BA58 ZB4BA68 ZB4BP1 ZB4BP2 ZB4BP3 ZB4BP4 ZB4BP5 ZB4BP6 ZB4BP18 ZB4BP38 ZB4BP48 ZB4BP58 ZB4BP68 ZB4BL1 ZB4BL2 ZB4BL3 ZB4BL4 ZB4BL5 ZB4BL6 ZB4BA16 ZB4BA26 ZB4BA36 ZB4BA46 ZB4BA56 ZB4BA66
13.00
16.00
25.80
29.00
13.00
19
a b
35.00
Color cap to be ordered separately, see page 19-39. For legend ordering information, see page 19-39.
ZB4BA36
Table 19.63:
Shape of Head
ZB4BA331
ZB4BA334
ZB4BL432
c
Cap Color Green White Green START White Green ON White RESET Black JOG Black Flush Red O White Black Red STOP White Black Red OFF White Black Black White c White Black Red O White Black Red Extended STOP White Black Red OFF White Black Cap supplied not clipped-in, allowing orientation of arrow in any one of 4 directions:
18.60
18.60
19-26
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
XB4 Operators
Refer to Catalog 9001CT0001
Table 19.64:
Shape of Head
ZB4BC24
30 mm
29.40
40 mm
29.40
ZB4BC2
60 mm
35.00
Table 19.65:
Shape of Head
ZB4BR2
Flush
17.60
Extended
17.60
ZB4BH02
Table 19.66:
ZB4BA8134
Two flush
Premarked
ZB4BL8312
ZB4BL9312
Legends. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19-37 to 19-39
Discount Schedule
19-27
19
22 mm Push Buttons
Table 19.67:
Shape of Head
40 mm
Red
ZB4BT84
54.00
ZB4BS834
30 mm Trigger action Turn-to-release a 40 mm 60 mm Trigger action Key release (No. 455) a 30 mm 40 mm 60 mm 40 mm Push-pull 60 mm Red Red Red marked EMO Red Red Red Red Black Red Black Red ZB4BS834 ZB4BS844 ZB4BS84430 ZB4BS864 ZB4BS934 ZB4BS944 b ZB4BS964 ZB4BT2 ZB4BT4 ZB4BX2 ZB4BX4 112.00 112.00 118.00 112.00 112.00 112.00 112.00 40.40 46.00
ZB4BT4
ZB4BS64
ZB4BS74
a b
Black ZB4BS42 30 mm 78.00 Red ZB4BS44 Black ZB4BS52 78.00 Red ZB4BS54 Red marked EMO ZB4BS5430 85.00 Turn-to-release 40 mm Yellow ZB4BS55 78.00 Yellow marked ZB4BS5550 85.00 Robot Stop Black ZB4BS62 60 mm 90.00 Red ZB4BS64 Black ZB4BS72 30 mm 112.00 Red ZB4BS74 Black ZB4BS12 Key release 40 mm 112.00 (No. 455) Red ZB4BS14 b Black ZB4BS22 60 mm 112.00 Red ZB4BS24 Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator. For emergency stop applications, always use a trigger action push button (per EN/IEC 13850). Other key numbers: key no. 421E: add the suffix 12 to the catalog number. key no. 458A: add the suffix 10 to the catalog number. key no. 520E: add the suffix 14 to the catalog number. key no. 3131A: add the suffix 20 to the catalog number. Example: The catalog number for a head with key No. 421E for a 2 position maintained, lockable selector switch, with key withdrawal from the left-hand position, becomes: ZB4BG212.
19
PUSH BUTTONS AND OPERATOR INTERFACE ZBY9330
Table 19.68:
Diameter 60 mm 90 mm
3.40
19-28
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.69:
Color
Number and Type of Positions Standard Lever a Extended Lever Catalog Number
$ Price
Black
2-maintained 2-momentary from right to left 3-maintained 3-momentary to center 3-momentary from left to center 3-momentary from right to center
Black
For colored lever, add the following code to the end of part number: 01white, 03green, 04red, 05yellow, 06blue (Example: ZB4BD204).
Table 19.70:
Type of Operator
Key (No. 455) c Note: The symbol indicates the key withdrawal position(s).
90.00
ZB4BG8
3-maintained ZB4BG04 ZB4BG5 ZB4BG9 ZB4BG09 b c See Table 19.71 for contact configurations. Other key numbers: key no. 421E: add the suffix 12 to the catalog number. key no. 458A: add the suffix 10 to the catalog number. key no. 520E: add the suffix 14 to the catalog number. key no. 3131A: add the suffix 20 to the catalog number. ZB4BG1 3-momentary from left to center ZB4BG01 ZB4BG7 116.00 ZB4BG8 3-momentary from right to center Example: For a head with key no. 421E for a 2 position maintained, lockable selector switch, with key withdrawal from the left-hand position, order ZB4BG212. ZB4BG05 ZB4BG08
3-momentary to center
Table 19.71:
Unit Type
Note: L=Left, C=Center, R=Right, O=Open, X=Closed Up Operator Plunger Position Down Contact Block Location Contacts N/O N/C L O X
315
45
315
45
C O X
R O X
L X O
C X O
R X O
L X O
C X O
R O X
L O X
C O X
R O X
L O X
C X O
R X O
Discount Schedule
19-29
19
22 mm Push Buttons
Table 19.72:
Shape of Head
For shaft 1/4 in. (6.35 mm) For potentiometer with shaft length 1.73 to 1.97 in. (44 to 50 mm) (potentiometer not included)
ZB4BD922 142.00
ZB4BD922
ZB4BD912
Table 19.73:
Description
2 direction
4 direction
Table 19.74:
XD4PA12
4 direction
19
Table 19.75:
PUSH BUTTONS AND OPERATOR INTERFACE
Shape of Head
ZB4BD28
Table 19.76:
Shape of Head
30.10
30.10
XB4BA81
1.185.12 0.55 14 5.1210.12 130257 30130
36.10
45.10
19-30
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.77:
Shape of Head
7.60
ZB4BV063
Protected LED only Fresnel (jeweled) lens a
7.60
7.60
ZB4BV04
For BA9s incandescent bulb, neon or LED Fresnel (jeweled) lens b a For use in bright ambient conditions, for example, in sunlight.
7.60
ZB4BV043S
Table 19.78:
Complete Bodies (Mounting Collar + Light Module for BA9s Incandescent Bulb, Neon or LED)
Light Source BA9s bulb 2.4 W max. Not included b BA9s incandescent bulb included BA9s incandescent bulb included Supply Voltage (V) <250 24 v 2 Watt 120 v 2.4 Watt 110120 Vac 50/60 Hz 230240 Vac 50/60 Hz 40050 Hz 440480 Vac 60 Hz 550600 Vac 60 Hz Catalog Number ZB4BV6 ZB4BV624 ZB4BV6120 ZB4BV3 ZB4BV4 ZB4BV5 ZB4BV8 ZB4BV9 98.00 $ Price 38.60 49.20 49.20
Description Screw clamp terminal connections Direct supply Direct supply Direct supply
ZB4BV6
Order bulb separately; see page 19-40. For BA9 LED, see page 19-116.
Table 19.79:
ZB4BV
ZB4BV
c d
White ZB4BVJ1 Green ZB4BVJ3 Red ZB4BVJ4 Yellow ZB4BVJ5 Blue ZB4BVJ6 White ZB4BVB1 Green ZB4BVB3 24 Vac/Vdc Red ZB4BVB4 Yellow ZB4BVB5 Blue ZB4BVB6 White ZB4BVBG1 Green ZB4BVBG3 24120 Vac/Vdc Red ZB4BVBG4 Yellow ZB4BVBG5 Blue ZB4BVBG6 White ZB4BVG1 Green ZB4BVG3 110120 Vac Red ZB4BVG4 Yellow ZB4BVG5 Blue ZB4BVG6 White ZB4BV18B1 Green ZB4BV18B3 Flashing 24 Vac/Vdc Red ZB4BV18B4 Yellow ZB4BV18B5 Blue ZB4BV18B6 White ZB4BV18G1 Green ZB4BV18G3 110120 Vac Red ZB4BV18G4 Yellow ZB4BV18G5 Blue ZB4BV18G6 For 240 V LED, replace the last B or G in the catalog number with an M. For example, ZB4BVB1 (24 V) becomes ZB4BVM1 (240 V). For Quick-Connect version, add 3 to the end of the catalog number Example: ZB4BVJ13 (Quick-Connect size 1 x 1/40" or 2 x 0.110"). 12 Vac/Vdc
57.00
57.00
57.00
57.00
66.00
66.00
Discount Schedule
19-31
19
22 mm Push Buttons
Table 19.80:
Shape of Head
Flush
18.60
ZB4BW333
31.00
16.00
ZB4BW563
Extended
13.00
ZB4BW113
29.40
Only use with light modules for a BA9s incandescent bulb, neon or LED
Flush
18.60
ZB4BW33
Extended
13.00
Table 19.81:
19
ZB4BW14 PUSH BUTTONS AND OPERATOR INTERFACE ZB4BW643 ZB4BH033 ZB4BH63
46.00
Table 19.82:
Flush
24.80
Extended
19.60
19-32
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.83:
Shape of Head
Only use with Protected LED light modules (Protected LED determines pilot light color) Black Red Green Red White Black Black Red 1 flush Green 1 central pilot light Red 1 extended White Black Only use with Protected LED light modules (Protected LED determines pilot light color)premarked Black 1 flush Red (marked I) Green 1 central pilot light Red 1 flush (marked O) White Black Black 1 flush Red (marked I) Green 1 central pilot light Red 1 extended (marked O) White Black a For IP66 degree of protection, install clear sealing boot ZBW008, see page 19-41. 1 flush 1 central pilot light 1 flush ZB4BW812743 ZB4BW813743 ZB4BW811723 ZB4BW832743 ZB4BW833743 ZB4BW831723 29.00 29.00
ZB4BW812743
ZB4BW823743
Table 19.84:
ZB4BW841723
2-maintained 2-momentary from right to left 3-maintained 3-momentary to center 3-momentary from right to center 3-momentary from left to center b Designate color as follows: 1white, 3green, 4red, 5yellow, 6blue.
ZB4BK1343
Table 19.85:
Unit Type
315
45
315
45
Up Operator Plunger Position Down Contact Block Location N/C Note: L=Left, R=Right, O=Open, X=Closed Contacts N/O L O X R O X L X O R X O L X O R O X L O X R O X L O X R X O
Discount Schedule
19-33
19
51.00
22 mm Push Buttons
Table 19.86:
ZB4BZ101
Type of Contact Catalog Number N.O. N.C. 1 ZB4BZ101 1 ZB4BZ102 2 ZB4BZ103 Screw clamp terminal connections 2 ZB4BZ104 1 1 ZB4BZ105 1 2 ZB4BZ141 For Quick-Connect version add 3 to the end of the catalog number Example: ZB4BZ1013 (Quick-Connect size 1 x 0.250" or 2 x 0.110"). For Ring Tongue compatible blocks add 9 to the end of the catalog number (Example: ZB4BZ1029). Electrical components with connection by printed circuit board pins are available. Refer to Catalog 9001CT0001. Electrical components with connection by plug-in connector are available. Refer to Catalog 9001CT0001. Description
Table 19.87:
Complete Bodies (Mounting Collar + Single Contact Block + Light Module with Protected LED)
Type of Contact c Supply Voltage d Color 24 Vac/Vdc 110120 Vac $ Price Catalog Number
Light Source
N.O.
N.C.
Screw clamp terminal connections White ZB4BW0B11 ZB4BW0G11 Green ZB4BW0B31 ZB4BW0G31 1 Red ZB4BW0B41 ZB4BW0G41 Yellow ZB4BW0B51 ZB4BW0G51 Blue ZB4BW0B61 ZB4BW0G61 White ZB4BW0B12 ZB4BW0G12 Green ZB4BW0B32 ZB4BW0G32 1 Red ZB4BW0B42 ZB4BW0G42 Yellow ZB4BW0B52 ZB4BW0G52 Blue ZB4BW0B62 ZB4BW0G62 White ZB4BW0B13 ZB4BW0G13 Green ZB4BW0B33 ZB4BW0G33 2 Red ZB4BW0B43 ZB4BW0G43 Yellow ZB4BW0B53 ZB4BW0G53 Blue ZB4BW0B63 ZB4BW0G63 White ZB4BW0B15 ZB4BW0G15 Green ZB4BW0B35 ZB4BW0G35 1 1 Red ZB4BW0B45 ZB4BW0G45 Yellow ZB4BW0B55 ZB4BW0G55 Blue ZB4BW0B65 ZB4BW0G65 Can be fitted with additional contact blocks, see page 19-35. For 240V LED, replace the B or G with M. (Example: change ZB4BW0B11 (24V) to ZB4BW0M11 (240V))
73.00
73.00
ZB4BW03
90.00
90.00
ZB4BW06
c d
19
PUSH BUTTONS AND OPERATOR INTERFACE ZB4BW05
Table 19.88:
Supply
Mounting Collar, Contact Block and Light Module (with screw clamp terminal connections) e
Light Source Supply Voltage Type of Contact e N.O. 1 2 1 1 1 1 1 1 1 N.C. 1 1 1 1 1 Color of Light Source Catalog Number $ Price
Screw clamp terminal connections BA9s 2.4 W max. bulb Not included e < 250 Vac/Vdc 110120 Vac 50/60 Hz Transformer type 1.2 VA, 6 V secondary BA9s incandescent bulb included 230240 Vac 50/60 Hz 440480 Vac 60 Hz e f Order bulb separately, see page 19-40. Can be fitted with additional contact blocks, see page 19-35. ZB4BW061 ZB4BW062 ZB4BW063 ZB4BW065 ZB4BW031 ZB4BW035 ZB4BW041 ZB4BW045 ZB4BW081 ZB4BW085 55.00 55.00 71.00 71.00 114.00 130.00 114.00 130.00 114.00 130.00
Direct supply
19-34
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.89:
Body/Mounting Collar
Catalog Number ZB4BZ009 $ Price 5.40
Table 19.90:
Description
ZB4BZ009
Standard single contact blocksab Standard double contact blocksab Special contact blocks for low power switching c Low-power switching
ZBE101
Dusty environment c (IP5X, 50 m dust) Early make 1 ZBE201 N/O Late break 1 ZBE202 N/C Staggered contacts Overlapping 1 1 ZB4BZ106 N/O+N/C Staggered 2 ZB4BZ107 N/O+N/O a For Quick-Connect version add 3 to the end of the catalog number Example: ZBE1013 (Quick-Connect size 1 x 0.250" or 2 x 0.110"). b For Ring Tongue compatible blocks add 9 to the end of the catalog number (Example: ZBE1029). c Cannot stack additional contact blocks onto these blocks.
Table 19.91:
Description
ZBE203
12 Vac/Vdc
52.00
24 Vac/Vdc
52.00
110120 Vac
52.00
24120 Vac/Vdc
52.00
230240 Vac
52.00
ZBVB
Direct supply for BA9s ZBV6 2.4 W max. bulb < 250 Vac/Vdc Not included f d Electrical components with connection by printed circuit board pins are available. Refer to Catalog 9001CT0001 for more details. e Electrical components with connection by plug-in connector are available. Refer to Catalog 9001CT0001 for more details. f See page 19-40 for bulb information.
33.20
Discount Schedule
19-35
19
22 mm Push Buttons
Table 19.92:
Body/Mounting Collar
For use with Contact block or light module Catalog Number ZB4BZ009 $ Price 5.40
ZB4BZ009
Contact Blocks a
Spring Terminal Connections, Contacts for Standard Applications
Description
Catalog Number
$ Price
Contact blocks
ZBE1015
Light Modules a
Spring Terminal Connections Description Supply voltage Color of light source White Green 12 Vac/Vdc Red Orange Blue Catalog Number ZBVJ15 ZBVJ35 ZBVJ45 ZBVJ55 ZBVJ65 ZBVB15 ZBVB35 ZBVB45 ZBVB55 ZBVB65 ZBVG15 ZBVG35 ZBVG45 ZBVG55 ZBVG65 ZBVM15 ZBVM35 ZBVM45 ZBVM55 ZBVM65 $ Price 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00
ZB4BZ1015
Integral LED (to combine with heads for integral LED)
TM
White Green 24 Vac/Vdc Red Orange Blue White Green 110120 Vac Red Orange Blue
19
PUSH BUTTONS AND OPERATOR INTERFACE
a
Additional blocks cannot be attached to the back of these contact blocks or light modules. However, spring terminal contact blocks can be mounted behind screw terminal contact blocks.
19-36
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.93:
Description
ZBZ32
Without legend a With blank legend (for engraving) Custom Legend (Specify Engraving) 2 lines of 11 characters (including spaces) maximum per line
14.20
3.40
ZBY101
ZBY2303
With legend marked with English language Black or red backgroundb
3.40
Table 19.94:
Table 19.95:
ZBZ34 ZBYH101
Description c Without legend
Table 19.96:
Description c Without legend With blank legend
ZBZ35
ZBY6H10
c For custom Legends, see page 19-38.
Discount Schedule
19-37
19
ZBZ33
ZBY610
a b
For marked legends, see page 19-38. Start functions: white letters on black background. Stop functions: white letters on red background (unless otherwise specified above).
22 mm Push Buttons
Table 19.97:
Color
ZBY02178
ZBY02303
Text Catalog Number O (black background) ZBY02146 O (red background) ZBY02931 I ZBY02147 International II ZBY02148 O-I ZBY02178 I-II ZBY02179 I-O-II ZBY02186 AUTO ZBY02115 AUTO-HAND ZBY02364 AUTO-O-HAND ZBY02385 CLOSE ZBY02314 DOWN ZBY02308 EMERGENCY STOP ZBY02330 FAST ZBY02328 FORWARD ZBY02305 FOR-REV ZBY02371 HAND ZBY02316 HAND-OFF-AUTO ZBY02387 Black or red background a INCH ZBY02321 JOG ZBY02382 LEFT ZBY02310 English OFF ZBY02312 OFF-ON ZBY02367 ON ZBY02311 OPEN ZBY02313 POWER ON ZBY02326 RESET (red background) ZBY02323 RESET (black background) ZBY02322 REVERSE ZBY02306 RIGHT ZBY02309 RUN ZBY02334 SLOW ZBY02327 START ZBY02303 STOP ZBY02304 STOP-START ZBY02366 UP ZBY02307 a Start functions: white letters on black background. Stop functions: white letters on red background (unless otherwise specified above).
1.70
1.70
19
PUSH BUTTONS AND OPERATOR INTERFACE
Table 19.98:
Description 8 x 27 mm 18 x 27 mm
1.70
Table 19.99:
Description
8 x 27 mm Custom Legend/Insert Only (Specify Engraving) 2 lines of 11 characters (including spaces) maximum per line (Example: ZBY01002 marked Robot) 18 x 27 mm Custom Legend/Insert Only (Specify Engraving) 3 lines of 11 characters (including spaces) maximum per line (Example: ZBY05002 marked Robot)
12.20
30 x 50 mm legend holders
12.20
19-38
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
XB4 Accessories
Refer to Catalog 9001CT0001
Table 19.100: Sheets of Legends for Push Buttons, Switches, and Pilot Lights
Description Marking Blank Text O I II III STOP Catalog Number ZBY1101 ZBY1146 ZBY1147 ZBY1148 ZBY1149 ZBY1304 ZBY1912 HAND OFF English ON START Legend Design Software: English, French, German, Spanish, Italian ZBY1316 ZBY1312 ZBY1311 ZBY1303 XBY2U $ Price 6.20
10.40
10.40 104.00
ZBY1101
Flush
2.00
ZBA
ZB4BA0 push button heads
4.20
Extended
2.00
ZBL
4.20
Set of 6 different colored caps: white, black, green, red, yellow, blue.
ZBA33
Green
ZBA346
b c d
White ZBA334 d Black ZBA335 d Red ZBA432 Oc White Black ZBA232 Red ZBA434 STOP c White Black ZBA234 Red ZBA435 OFF White Black ZBA235 Rc White Blue ZBA639 Start functions: white letters on black background. Stop functions: white letters on red background (unless otherwise specified). Double injection molded marking. Cap supplied not clipped-in, allowing orientation of arrow in any one of 4 directions:
Discount Schedule
19-39
19
22 mm Push Buttons
XB4 Accessories
Refer to Catalog 9001CT0001
www.schneider-electric.us
Yellow
ZBZ3605
108.00
ZBZ3605
Metal guards Padlockable
Chromium Plated Black Red Yellow Blue Yellow Yellow Yellow Black Red
ZBZ1600 ZBZ1602 ZBZ1604 ZBZ1605 ZBZ1606 ZB4BZ1905 ZB4BZ2005 ZB4BZ2105 ZB4BZ62 ZB4BZ64 ZB4BZ011 ZB4SZ3 ZB5SZ3 Catalog Number ZBY9101T ZBY9330T
108.00
ZBZ160
ZB4BZ6
Plastic guardsb
25.80
Padlockable flaps Mounting kit Metal blanking plug, round chromium plated a Plastic blanking plug, round black with mounting nut Description
ZB4BZ011
ZB4SZ3
ZB5SZ3
Marking Color Without Yellow 60 mm Legend for padlocking device ZBZ3605 EMERGENCY STOP Yellow a Requires a ZB4BZ009 body/mounting collar for mounting, see page 19-35. b For additional information, refer to publication 9001DB0601R6/06. c Standard circular legends are not compatible with this product. Use special legends ZBY T listed above. d Maximum panel thickness is 2.5 mm.
DL1CE
DL1CF
11.00
19
XBFX13 ZBZ8 PUSH BUTTONS AND OPERATOR INTERFACE ZBZ8 ZBDD2 ZBG455 ZBG455P
Any Harmony XB4 metal, mushroom head push button d, 40 mm or 60 mm (except ZB4BR16)
Set of 2 keys
11.00
23.40
19-40
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
XB4 Accessories
Refer to Catalog 9001CT0001
ZBP0
13.00
Pilot lights
5.40
5.40
5.40
ZBV013
Pilot lights
5.40
ZBV01
5.40
5.40
Discount Schedule
19-41
19
22 mm Push Buttons
Table 19.111: Non-Illuminated Push Buttons, Momentary (screw clamp terminal connections)
Shape of Head Type of Push Type of Contact N.O. N.C. Marking Cap Color Black Green Yellow Blue Red Black Green Red Yellow Blue Green Catalog Number XB5AA21 XB5AA31 XB5AA51 XB5AA61 XB5AA42 XB5AA25 XB5AA35 XB5AA45 XB5AA55 XB5AA65 XB5AA3311 (Components) (ZB5AZ101 + ZB5AA2) (ZB5AZ101 + ZB5AA3) (ZB5AZ101 + ZB5AA5) (ZB5AZ101 + ZB5AA6) (ZB5AZ102 + ZB5AA4) (ZB5AZ105 + ZB5AA2) (ZB5AZ105 + ZB5AA3) (ZB5AZ105 + ZB5AA4) (ZB5AZ105 + ZB5AA5) (ZB5AZ105 + ZB5AA6) (ZB5AZ101 + ZB5AA331) $ Price
38.50 38.50
XB5AA31
Flush
56.00
Flush
I (white)
44.70
XB5AA4322
Flush 1 O (white) Red Black Green Yellow Blue Red Red Red XB5AA4322 XB5AP21 XB5AP31 XB5AP51 XB5AP61 XB5AP42 XB5AL42 XB5AL45 (ZB5AZ102 + ZB5AA432) (ZB5AZ101 + ZB5AP2) (ZB5AZ101 + ZB5AP3) (ZB5AZ101 + ZB5AP5) (ZB5AZ101 + ZB5AP6) (ZB5AZ102 + ZB5AP4) (ZB5AZ102 + ZB5AL4) (ZB5AZ105 + ZB5AL4) 44.70
1 1 1
XB5AP51
Extended
Mushroom head 40 mm
Black
XB5AC21
(ZB5AZ101 + ZB5AC2)
56.00
XB5AL42
Table 19.112: Two Button Push Buttons, Momentary (screw clamp terminal connections)
Shape of Head Type of Push One flush green push (marked I) One extended red push (marked O) Type of Contact N.O. N.C. Degree of Protection Catalog Number (Components) $ Price
IP40
XB5AL845
(ZB5AZ105 + ZB5AL8434)
69.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
XB5AC21
Legends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19-58 to 19-60
XB5AL845
19-42
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.113: Non-Illuminated Emergency Stop and Emergency Off Mushroom Head Push Buttons, 40 mm (Red) (screw clamp terminal connections)
Type of Contact Shape of Head Type of Push N.O. N.C. Catalog Number (Components) $ Price
XB5AS9445
Trigger action push-pulla
XB5AT845
(ZB5AZ105 + ZB5AT84)
101.00
1 2
XB5AS8445 XB5AS8444
XB5AT42
Trigger action Key release (No. 455)a 1 1 XB5AS9445 (ZB5AZ105+ ZB5AS944) 165.00
Push-pull
XB5AT42
(ZB5AZ102 + ZB5AT4)
68.00
XB5AS542
Turn-to-release
XB5AS542
(ZB5AZ102 + ZB5AS54)
110.00
XB5AS142
(ZB5AZ102 + ZB5AS14)
147.00
Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator. For emergency stop applications, always use a trigger action push button (per EN/IEC 13850).
Table 19.114: Non-Illuminated Selector Switches and Key Switches (screw clamp terminal connections) b
Shape of Head Type of Contact Type of Operator N.O. 1 1 Standard lever, black 3-maintained 2 3-momentary to center 1 2-maintained XB5AD53 (ZB5AZ103 + ZB5AD5) 75.00 XB5AD33 (ZB5AZ103 + ZB5AD3) 68.00 N.C. 1 Number and Type of Positions 2-maintained 2-maintained Catalog Number (Components) $ Price
XB5AD21 XB5AD25
51.00 68.00
XB5AD33
XB5AJ21
(ZB5AZ101 + ZB5AJ2)
51.00
XB5AJ33
(ZB5AZ103 + ZB5AJ3)
68.00
XB5AJ33
XB5AJ53 XB5AG21
2-maintained
2-momentary to left
XB5AG61
(ZB5AZ101 + ZB5AG6)
123.00
XB5AG03
(ZB5AZ103 + ZB5AG0)
141.00
XB5AG33
b See 19-49 for contact configurations. Note: The symbol indicates key withdrawal position(s) Legends. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19-58 to 19-60
Discount Schedule
19-43
19
XB5AG41
22 mm Push Buttons
LED
24 Vac/Vdc
72.00
XB5AVB1
110120 Vac
72.00
Table 19.116: Pilot Lights for BA9s Bulb (screw clamp terminal connections)
Shape of Head Supply Voltage Color Catalog Number (Components) (ZB5AV6 + ZB5AV01) (ZB5AV6 + ZB5AV03) (ZB5AV6 + ZB5AV04) (ZB5AV6 + ZB5AV05) (ZB5AV3 + ZB5AV01) (ZB5AV3 + ZB5AV03) (ZB5AV3 + ZB5AV04) (ZB5AV3 + ZB5AV05) $ Price Direct supply, for BA9s (incandescent, LED, neon) V < 250 V, 2.4 W bulb (bulb not included) b White XB5AV61 Green XB5AV63 < 250 Vac/Vdc Red XB5AV64 Yellow XB5AV65 Transformer type with 1.2 VA, 6 V secondary. BA9s incandescent bulb included White XB5AV31 Green XB5AV33 110120 Vac 50/60 Hz Red XB5AV34 Yellow XB5AV35
XB5AV63
51.00
117.00
Table 19.117: Illuminated Push Buttons, Momentary (screw clamp terminal connections) a
XB5AV34
Shape of Head Flush White Green Red Yellow Blue White Green Red Yellow Blue White Green Red Yellow White Green Red Yellow White Green Red Yellow XB5AW31B5 XB5AW33B5 XB5AW34B5 XB5AW35B5 XB5AW36B5 XB5AW31G5 XB5AW33G5 XB5AW34G5 XB5AW35G5 XB5AW36G5 XB5AW3165 XB5AW3365 XB5AW3465 XB5AW3565 XB5AW3135 XB5AW3335 XB5AW3435 XB5AW3535 XB5AW3145 XB5AW3345 XB5AW3445 XB5AW3545 (ZB5AW0B15 + ZB5AW313) (ZB5AW0B35 + ZB5AW333) (ZB5AW0B45 + ZB5AW343) (ZB5AW0B55 + ZB5AW353) (ZB5AW0B65 + ZB5AW363) (ZB5AW0G15 + ZB5AW313) (ZB5AW0G35 + ZB5AW333) (ZB5AW0G45 + ZB5AW343) (ZB5AW0G55 + ZB5AW353) (ZB5AW0G65 + ZB5AW363) (ZB5AW065 + ZB5AW31) (ZB5AW065 + ZB5AW33) (ZB5AW065 + ZB5AW34) (ZB5AW065 + ZB5AW35) (ZB5AW035 + ZB5AW31) (ZB5AW035 + ZB5AW33) (ZB5AW035 + ZB5AW34) (ZB5AW035 + ZB5AW35) (ZB5AW045 + ZB5AW31) (ZB5AW045 + ZB5AW33) (ZB5AW045 + ZB5AW34) (ZB5AW045 + ZB5AW35) Description Type of Contact N.O. N.C. Supply Voltage Color of Push Catalog Number (Components) $ Price
119.00
XB5AW31B5
Direct supply for BA9s 2.4 W max. bulb not included
119.00
19
PUSH BUTTONS AND OPERATOR INTERFACE XB5AW3465
Extended
99.00
163.00
163.00
XB5AW3335
a b
White XB5AW11B5 (ZB5AW0B15 + ZB5AW113) Green XB5AW13B5 (ZB5AW0B35 + ZB5AW133) 24 Vac/Vdc Red XB5AW14B5 (ZB5AW0B45 + ZB5AW143) Yellow XB5AW15B5 (ZB5AW0B55 + ZB5AW153) Blue XB5AW16B5 (ZB5AW0B65 + ZB5AW163) 1 1 White XB5AW11G5 (ZB5AW0G15 + ZB5AW113) Green XB5AW13G5 (ZB5AW0G35 + ZB5AW133) 110120 Vac Red XB5AW14G5 (ZB5AW0G45 + ZB5AW143) Yellow XB5AW15G5 (ZB5AW0G55 + ZB5AW153) Blue XB5AW16G5 (ZB5AW0G65 + ZB5AW163) For 240V LED, replace the B or G with M. (Example: XB5APVB1 (24 V) to XB5APVM1 (240 Vac only)) For bulb information, refer to page 19-61
113.00
113.00
19-44
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
6 colors b White Black Green Red Yellow Blue Gray White Green Red Yellow Blue White Black Green Red Yellow Blue White Black Green Red Yellow Blue White Green Red Yellow Blue White Black Green Red Yellow Blue White Black Green Red Yellow Blue White Black Green Red Yellow Blue White Black Green Red Yellow Blue White Black Green Red Yellow Blue
ZB5AA9 ZB5AA1 ZB5AA2 ZB5AA3 ZB5AA4 ZB5AA5 ZB5AA6 ZB5AA8 ZB5AA18 ZB5AA38 ZB5AA48 ZB5AA58 ZB5AA68 ZB5AL1 ZB5AL2 ZB5AL3 ZB5AL4 ZB5AL5 ZB5AL6 ZB5AP1 ZB5AP2 ZB5AP3 ZB5AP4 ZB5AP5 ZB5AP6 ZB5AP18 ZB5AP38 ZB5AP48 ZB5AP58 ZB5AP68 ZB5AA14 ZB5AA24 ZB5AA34 ZB5AA44 ZB5AA54 ZB5AA64 ZB5CA1 ZB5CA2 ZB5CA3 ZB5CA4 ZB5CA5 ZB5CA6 ZB5CL1 ZB5CL2 ZB5CL3 ZB5CL4 ZB5CL5 ZB5CL6 ZB5 AA16 ZB5 AA26 ZB5 AA36 ZB5 AA46 ZB5 AA56 ZB5 AA66 ZB5 CA16 ZB5 CA26 ZB5 CA36 ZB5 CA46 ZB5 CA56 ZB5 CA66
13.00
ZB5AA0
Flush
13.00
16.00
ZB5AA5
Extended
13.00
25.80
ZB5AL3
29.00
32.20
Extended
27.00
ZB5CA2
a b c
Order color cap separately, see page 19-60. Six colored caps included with head (white, black, green, red, yellow, blue). For legend ordering information see page 19-60.
Discount Schedule
19-45
19
32.20
ZB5AP1
Flush
27.00
22 mm Push Buttons
ZB5AA331
T Flush O STOP OFF UP
18.60
ZB5AA432
18.60
32.00 32.00
ZB5AL232
a
Flush
Cap supplied not clipped-in, allowing orientation of arrow in any one of 4 directions:
30 mm
29.40
19
PUSH BUTTONS AND OPERATOR INTERFACE ZB5AC2 ZB5AR4
40 mm
29.40
60 mm
35.00
19-46
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Flush
17.60
ZB5AH04
Extended
17.60
Flush
35.20
ZB5AL8334
ZB5AL8434
ZB5AL9334
Discount Schedule
19-47
19
22 mm Push Buttons
40 mm
Red
ZB5AT84
54.00
ZB5AS844
30 mm Trigger action Turn-to-release b 40 mm 30 mm Red Red Red Red Black Red Black Red Black Red Black Red Black Red Yellow Black Red Black Red Black Red Black Red ZB5AS844 ZB5AS934 ZB5AS944 a ZB5AS964 ZB5AT24 ZB5AT44 ZB5AT2 ZB5AT4 ZB5AX2 ZB5AX4 ZB5AS42 ZB5AS44 ZB5AS52 ZB5AS54 ZB5AS55 ZB5AS62 ZB5AS64 ZB5AS72 ZB5AS74 ZB5AS12 ZB5AS14 a ZB5AS22 ZB5AS24 112.00 112.00 112.00 112.00 40.40 40.40 46.00 78.00 78.00 90.00 112.00 112.00 112.00 Red ZB5AS834 112.00
ZB5AS934
40 mm 60 mm 30 mm
Push-pull
40 mm 60 mm
ZB5AT4
30 mm Turn-to-release 40 mm 60 mm 30 mm
ZB5AS54
40 mm 60 mm
Other key numbers: key no. 421E: add the suffix 12 to the catalog number. key no. 458A: add the suffix 10 to the catalog number. key no. 520E: add the suffix 14 to the catalog number. key no. 3131A: add the suffix 20 to the catalog number. Example: The catalog number for a 40 mm red mushroom head for a trigger action, maintained push button, with release by key no. 421E becomes: ZB5AS94412. Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator. For emergency stop applications, always use a trigger action push button (per EN/IEC 13850).
19
ZB5AS64 PUSH BUTTONS AND OPERATOR INTERFACE ZBY9330
Table 19.124: Circular Legends for Emergency Stop Mushroom Heads (yellow background)
Diameter 60 mm 90 mm Text Blank EMERGENCY STOP Blank EMERGENCY STOP Catalog Number ZBY9101 ZBY9330 ZBY8101 ZBY8330 $ Price
3.40
19-48
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Color
Number and Type of Positions Standard Lever a Extended Lever Catalog Number
$ Price
2-maintained 2-momentary from right to left 3-maintained 3-momentary to center 3-momentary from left to center 3-momentary from right to center
For colored lever, add the following code to the end of catalog number: 01white, 03green, 04red, 05yellow, 06blue (Example: ZB5AD204).
ZB5AG
90.00
116.00
Unit Type
315
45
315
45
Discount Schedule
19-49
19
22 mm Push Buttons
XB5AA
2 direction
4 direction
XD5PA12
19
PUSH BUTTONS AND OPERATOR INTERFACE
4 direction
XB5DS
Indication 09999.9
Supply Voltage 1224 Vdc or Vac, 50/60 Hz 120 Vac, 60 Hz 230240 Vac, 50 Hz
$ Price 383.00
XB5KS
c UR E191025, XHNR2 and XHNR8.
ZB5AD28
19-50
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
7.60
ZB5AV053
Protected LED only Fresnel (jeweled) lens a
7.60
7.60
ZB5AV01
For BA9s incandescent bulb, neon or LED Fresnel (jeweled) lens b
7.60
27.00
ZB5CV063
a b
For use in bright ambient conditions (i.e., sunlight). Order bulb separately; see page 19-40. For BA9 LED, see page 19-116.
Discount Schedule
19-51
19
22 mm Push Buttons
Table 19.137: Complete Bodies (Mounting Collar + Light Module for BA9s Incandescent Bulb, Neon or LED)
Description Screw clamp terminal connections Direct supply Direct supply Direct supply BA9s bulb 2.4 W max. Not included a BA9s incandescent bulb included BA9s incandescent bulb included <250 24 V 2 W 120 V 2.4 W 110120 Vac 50/60 Hz 230240 Vac 50/60 Hz 40050 Hz 440480 Vac 60 Hz 550600 Vac 60 Hz ZB5AV6 ZB5AV624 ZB5AV6120 ZB5AV3 ZB5AV4 ZB5AV5 ZB5AV8 ZB5AV9 98.00 38.60 49.20 49.20 Light Source Supply Voltage (V) Catalog Number $ Price
ZB5AV6
Transformer type 1.2 VA, 6 V secondary BA9s incandescent bulb included
Table 19.138: Complete Bodies (Mounting Collar + Light Module with Protected LED) bc
Light Source Supply Voltage Color of Light Source Catalog Number $ Price
ZB5AV3
Screw clamp terminal connections White ZB5AVJ1 Green ZB5AVJ3 12 Vac/Vdc Red ZB5AVJ4 Yellow ZB5AVJ5 Blue ZB5AVJ6 White ZB5AVB1 Green ZB5AVB3 24 Vac/Vdc Red ZB5AVB4 Yellow ZB5AVB5 Blue ZB5AVB6 White ZB5AVBG1 Green ZB5AVBG3 24120 Vac/Vdc Red ZB5AVBG4 Yellow ZB5AVBG5 Blue ZB5AVBG6 White ZB5AVG1 Green ZB5AVG3 110120 Vac Red ZB5AVG4 Yellow ZB5AVG5 Blue ZB5AVG6 White ZB5AV18B1 Green ZB5AV18B3 Flashing 24 Vac/Vdc Red ZB5AV18B4 Yellow ZB5AV18B5 Blue ZB5AV18B6 White ZB5AV18G1 Green ZB5AV18G3 110120 Vac Red ZB5AV18G4 Yellow ZB5AV18G5 Blue ZB5AV18G6 b For Quick-Connect version, add 3 to the end of the catalog number Example: ZB5AVJ13 (Quick-Connect size 1 x 0.250" or 2 x 0.110"). c For 240 V LED, replace the B or G with M. (Example: ZB5AVB1 (24V) to ZB5AVM1 (240V))
57.00
57.00
57.00
57.00
19
PUSH BUTTONS AND OPERATOR INTERFACE ZB5AV
66.00
66.00
19-52
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Flush
18.60
ZB5AW313
31.00
16.00
ZB5AW363
Extended
13.00
27.00
ZB5AW143
Extended
27.00
Only use with light modules for a BA9s incandescent bulb, neon or LED
Flush
18.60
ZB5CW313
Extended
13.00
ZB5AW33
Flush
24.80
Extended
19.60
Discount Schedule
19-53
19
22 mm Push Buttons
Table 19.141: Two Button with Clear Pilot Light, Momentary (IP40) a
Shape of Head Description Color of Pushers Catalog Number $ Price Only use with Protected LED light modules (Protected LED determines pilot light color) Black Red Green Red White Black Black Red 1 flush Green 1 central pilot light Red 1 extended White Black Only use with Protected LED light modules (Protected LED determines pilot light color)premarked Black 1 flush Red (marked I) Green 1 central pilot light Red 1 flush (marked O) White Black Black 1 flush Red (marked I) Green 1 central pilot light Red 1 extended (marked O) White Black a For IP66 degree of protection, install clear sealing boot ZBW008, see page 19-62. 1 flush 1 central pilot light 1 flush ZB5AW812743 ZB5AW813743 ZB5AW811723 ZB5AW832743 ZB5AW833743 ZB5AW831723 29.00 29.00
ZB5AW833743
ZB5AW823743
ZB5AW843743
63.00
Table 19.143: Emergency Stop, Trigger Action and Mechanical Latching Push Button with Mechanical State Indicator for Elevator Inspection Box ApplicationsHeads Only
Shape of Head Type of Reset Push-pull (40 mm) Color Red Catalog Number ZB5AT8643M $ Price 124.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
ZB5AW7
ZB5AT8643M
3-maintained
ZB5AK13b3
35.00
3-momentary to center
ZB5AK15b3
51.00
ZB5AK1213
ZB5AK18b3
51.00
3-momentary from left to center b Designate color as follows: 1white, 3green, 4red, 5yellow, 6blue
ZB5AK17b3
51.00
315
45
315
45
19-54
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
NOTE: For the Quick-Connect version, add the numeral 3 to the end of the catalog number. Example: ZB5AZ1013 (Quick-Connect size 1 x 0.250" or 2 x 0.110"). Table 19.146: Contact Blocks (Mounting Collar with Contact Blocks) abc
Type of Contact Catalog Number N.O. N.C. 1 ZB5AZ101 1 ZB5AZ102 2 ZB5AZ103 Screw clamp terminal connections 2 ZB5AZ104 1 1 ZB5AZ105 1 2 ZB5AZ141 a For Ring Tongue compatible blocks add 9 to the end of the catalog number (Example: ZB5AZ1029). b Electrical components with connection by printed circuit board pins are available. Refer to Catalog 9001CT0001 for more information. c Electrical components with connection by plug-in connector are available. Refer to Catalog 9001CT0001 for more information. Description $ Price 22.00 22.00 38.20 38.20 38.20 55.00
ZB5AZ101
Table 19.147: Complete Bodies (Mounting Collar + Single Contact Block + Light Module with Protected LED)
Type of Contact e Light Source N.O. Screw clamp terminal connections White Green Red Yellow Blue White Green Red Yellow Blue White Green Red Yellow Blue White Green Red Yellow Blue ZB5AW0B11 ZB5AW0B31 ZB5AW0B41 ZB5AW0B51 ZB5AW0B61 ZB5AW0B12 ZB5AW0B32 ZB5AW0B42 ZB5AW0B52 ZB5AW0B62 ZB5AW0B13 ZB5AW0B33 ZB5AW0B43 ZB5AW0B53 ZB5AW0B63 ZB5AW0B15 ZB5AW0B35 ZB5AW0B45 ZB5AW0B55 ZB5AW0B65 ZB5AW0G11 ZB5AW0G31 ZB5AW0G41 ZB5AW0G51 ZB5AW0G61 ZB5AW0G12 ZB5AW0G32 ZB5AW0G42 ZB5AW0G52 ZB5AW0G62 ZB5AW0G13 ZB5AW0G33 ZB5AW0G43 ZB5AW0G53 ZB5AW0G63 ZB5AW0G15 ZB5AW0G35 ZB5AW0G45 ZB5AW0G55 ZB5AW0G65 N.C. Color 24 Vac/Vdc Catalog Number Supply Voltage d 110120 Vac $ Price
73.00
73.00
ZB5AW01
90.00
90.00
For 240V LED, replace the B or G with M. (Example: change ZB5AW0B11 (24 V) to ZB5AW0M11 (240 V))
Table 19.148: Mounting Collar, Contact Block and Light Module (with screw clamp terminal connections) e
Supply Light Source Supply Voltage Type of Contact e N.O. N.C. 1 1 1 1 1 Color of Light Source Catalog Number $ Price
ZB5AW065
Direct supply
ZB5AW035
Discount Schedule
19-55
19
1 2 1 1 110120 Vac 50/60 Hz 1 Transformer type BA9s 1 230240 Vac 1.2 VA, 6 V incandescent 50/60 Hz 1 secondary bulb included 1 440480 Vac 60 Hz 1 e Can be fitted with additional contact blocks, see page 19-56. f Order bulb separately, see page 19-61. BA9s 2.4 W max. bulb Not included f < 250 Vac/Vdc
ZB5AW061 ZB5AW062 ZB5AW063 ZB5AW065 ZB5AW031 ZB5AW035 ZB5AW041 ZB5AW045 ZB5AW081 ZB5AW085
55.00 55.00 71.00 71.00 114.00 130.00 114.00 130.00 114.00 130.00
22 mm Push Buttons
Table 19.150: Add-On Contact Block (with screw clamp terminal connections) de
Description Type of Contact N.O. 1 2 1 1 1 N.C. 1 2 1 1 1 Catalog Number ZBE101 ZBE102 ZBE203 ZBE204 ZBE205 ZBE1016 ZBE1026 ZBE1016P ZBE1026P $ Price 16.40 16.40 33.20 33.20 33.20 32.80 32.80 32.80 32.80 16.40 16.40 32.80 32.80
ZB5AZ009
Standard single contact blocksab Standard double contact blocksab Special contact blocks for low-power switching c Low-power switching
ZBE101
Dusty environment c (IP5X, 50 m dust) Early make 1 ZBE201 N/O Late break 1 ZBE202 N/C Staggered contacts Overlapping 1 1 ZB4BZ106 N/O+N/C Staggered 2 ZB4BZ107 N/O+N/O a For Quick-Connect version add 3 to the end of the catalog number (Example: ZBE1013) (Quick-Connect size 1 x 0.250" or 2 x 0.110"). b For Ring Tongue compatible blocks add 9 to the end of the catalog number (Example: ZBE1029). c Cannot stack additional contact blocks onto these blocks.
12 Vac/Vdc
52.00
24 Vac/Vdc
52.00
110120 Vac
52.00
19
24120 Vac/Vdc
52.00
ZBVB
230240 Vac
52.00
Direct supply for BA9s ZBV6 < 250 Vac/Vdc (2.4 W max. bulb not includedsee page 19-61) d Electrical components with connection by printed circuit board pins are available. Refer to Catalog 9001CT0001 for more details. e Electrical components with connection by plug-in connector are available. Refer to Catalog 9001CT0001 for more details.
33.20
19-56
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
Table 19.152: Spring Terminal Products for XB5 22 mm Push Buttons Body/Mounting Collar
For Use With Contact block or light module Catalog Number ZB5AZ009 $ Price 5.40
ZB5AZ009
Contact Blocks a
Spring Terminal Connections, Contacts for Standard Applications
Description
Catalog Number
$ Price
Contact blocks
ZBE1015
Light Modules a
Spring Terminal Connections Description Supply Voltage Color of Light Source White Green 12 Vac/Vdc Red Orange Blue Catalog Number ZBVJ15 ZBVJ35 ZBVJ45 ZBVJ55 ZBVJ65 ZBVB15 ZBVB35 ZBVB45 ZBVB55 ZBVB65 ZBVG15 ZBVG35 ZBVG45 ZBVG55 ZBVG65 ZBVM15 ZBVM35 ZBVM45 ZBVM55 ZBVM65 $ Price 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00 57.00
ZB5AZ1015
Integral LED (to combine with heads for integral LED)
TM
White Green 24 Vac/Vdc Red Orange Blue White Green 110120 Vac Red Orange Blue White Green 230240 Vac Red Orange Blue a Additional blocks cannot be attached to the back of these contact blocks or light modules.
Discount Schedule
19-57
19
22 mm Push Buttons
14.20
ZBZ32
With international language marked legend Black or red backgroundb
3.40
ZBY101
ZBY2303
3.40
19
ZBZ33 PUSH BUTTONS AND OPERATOR INTERFACE ZBY610
a b Description c Without legend insert With blank legend insert For use with Circular and square heads Circular and square heads
For legends, see page 19-59. Start functions: white letters on black background. Stop functions: white letters on red background (unless otherwise specified above).
Table 19.155: 30 x 40 mm legend holder (flush mounting with bezel) for 8 x 27 mm legends
ZBZ34 ZBYH101
Description c Without legend With blank legend Color Black or red background White or yellow background Catalog Number ZBZ34 ZBY2H101 ZBY4H101 $ Price 2.00 3.40
Table 19.156: 30 x 50 mm legend holder (flush mounting with bezel) for 18 x 27 mm legends
Description c Without legend With blank legend Color Black or red background White or yellow background c For custom legends, please see page 19-59 Catalog Number ZBZ35 ZBY6H101 ZBY6H102 $ Price 4.20 5.40
ZBZ35
ZBY6H10
19-58
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
1.70
ZBY02178
ZBY02303
1.70
1.70
30 x 40 mm legend holders
12.20
30 x 50 mm legend holders
12.20
Discount Schedule
19-59
19
22 mm Push Buttons
XB5 Accessories
Refer to Catalog 9001CT0001
www.schneider-electric.us
Table 19.160: Sheets of Legends for Push Buttons, Switches, and Pilot Lights
Description Marking BlankRound BlankSquare legends Text Catalog Number ZBY1101 ZBCY1101 ZBY1146 ZBY1147 ZBY1148 ZBY1149 ZBY1304 ZBY1912 HAND OFF English ON START Legend Design Software: English, French, German, Spanish, Italian ZBY1316 ZBY1312 ZBY1311 ZBY1303 XBY2U $ Price 6.20 6.20
International
O I II III STOP
10.40
10.40 104.00
ZBY1101
Flush
2.00
ZBA
ZB5AA0 push button heads
4.20
Extended
2.00
4.20
ZBL
19
PUSH BUTTONS AND OPERATOR INTERFACE ZBA33
a b c
START b ON UP b DOWNb
Green White Black Red Black Red Black Red Black Blue
ZBA346 ZBA334c ZBA335c ZBA432 ZBA232 ZBA434 ZBA234 ZBA435 ZBA235 ZBA639
Rb White Set of 6 different colored caps: white, black, green, red, yellow, blue. Double injection molded marking. Cap supplied not clipped-in, allowing orientation of arrow in any one of 4 directions:
19-60
Discount Schedule
22 mm Push Buttons
www.schneider-electric.us
XB5 Accessories
Refer to Catalog 9001CT0001
um inim um mm 6 m maxim mm 8
Yellow
ZBZ3605
108.00
ZBZ3605
Metal guards Padlockable
Chromium Plated Black Red Yellow Blue Yellow Yellow Yellow Black Red Black Black Black Color Yellow Yellow
ZBZ1600 ZBZ1602 ZBZ1604 ZBZ1605 ZBZ1606 ZB4BZ1905 ZB4BZ2005 ZB4BZ2105 ZB4BZ62 ZB4BZ64 ZB5SZ3 ZB5SZ5 ZB5AZ31 ZB5AZ901 ZB5AZ905 ZB5AZ902 Catalog Number ZBY9101T ZBY9330T
108.00
ZBZ160
Plastic guardsb
25.80
Padlockable flaps Plastic blanking plug, rounda Plastic blanking plug, squarea Square insert Mounting nut Tool Plate Description
ZB4BZ6
ZB4SZ3
ZB5SZ3
For 22 mm units with round heads For 22 mm units with square heads To give square appearance to ZB5A round heads Operator For tightening mounting nut ZB5AZ901 Anti-rotation of head Marking Without 60 mm Legend for padlocking device ZBZ3605 EMERGENCY STOP a Mounting nut included with blanking plug. b For additional information, refer to publication 9001DB0601R6/06. c Standard circular legends are not compatible with this product. Use special legends ZBY T listed above. d Maximum panel thickness is 2.5 mm.
DLCE
DL1CF
11.00
ZBZ8
Bellows Seals for harsh environments (Humidity, dust, high-pressure cleaning) XB5 plastic mushroom head push button e, 40 mm or 60 mm
ZBDD2
$ Price 12.40
Set of 2 keys
11.00
ZBG455
Set of 2 keys, One of which is supplied booted (rubber boot)
23.40
ZBG455P
Discount Schedule
19-61
19
XBFX13
ZBZ8
22 mm Push Buttons
XB5 Accessories
Refer to Catalog 9001CT0001
www.schneider-electric.us
ZBP0
ZBW008
Pilot lights
5.40
5.40
ZBV013
Illuminated push buttons with extended push
5.40
ZBV01
Pilot lights
5.40
19
PUSH BUTTONS AND OPERATOR INTERFACE
5.40
5.40
Square lens caps for Protected LED light modules (ZB5C operators only) Pilot lights
9.40
9.40
9.40
19-62
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.171: Non-Illuminated Momentary Push Button OperatorsUL Types 4, 13/NEMA 4, 13 For use in hazardous locationsSee page 19-83. Contact blocks and legend plate not included unless otherwise noted.
Description Color Black Red Green Universal a Other b Black Red Green Universal a Other b Black Red Green Universal a Otherb Operator with 1 N.O. and 1 N.C. Contact (KA1) KR1BH13 KR1RH13 KR1GH13 KR1UH13 KR1bH13 KR3BH13 KR3RH13 KR3GH13 KR3UH13 KR3bH13 KR2BH13 KR2RH13 KR2GH13 KR2UH13 KR2bH13 $ Price Operator with 1 N.O. Contact (KA2) KR1BH5 KR1RH5 KR1GH5 KR1UH5 KR1bH5 KR3BH5 KR3RH5 KR3GH5 KR3UH5 KR3bH5 KR2BH5 KR2RH5 KR2GH5 KR2UH5 KR2bH5 Operator with 1 N.C. Contact (KA3) KR1BH6 KR1RH6 KR1GH6 KR1UH6 KR1bH6 KR3BH6 KR3RH6 KR3GH6 KR3UH6 KR3bH6 KR2BH6 KR2RH6 KR2GH6 KR2UH6 KR2bH6 $ Price Operator Only with No Contacts KR1B KR1R KR1G KR1U KR1b KR3B KR3R KR3G KR3U KR3b KR2B KR2R KR2G KR2U KR2b $ Price
Full Guard
9001KR1B
No Guard
89.00
66.00
38.60
9001KR3B
Extended Guard
9001KR2B
Snap-In Plastic Mushroom Button Black KR4BH13 KR4BH5 Red KR4RH13 KR4RH5 Red c KR4R05H13 KR4R05H5 138.00 Green KR4GH13 KR4GH5 Other d KR4dH13 KR4dH5 Screw-On Plastic Mushroom Button with Set Screw Security e Black KR24BH13 KR24BH5 Red KR24RH13 KR24RH5 138.00 Green KR24GH13 KR24GH5 Otherd KR24dH13 KR24dH5 Screw-in Metal Mushroom Button with Set Screw Security Black Red Green Snap-In Plastic Mushroom Button Black KR5BH13 KR5BH5 Red KR5RH13 KR5RH5 Red c KR5R05H13 c 138.00 KR5R05H5 c Green KR5GH13 KR5GH5 Otherd KR5dH13 KR5dH5 Screw-On Plastic Mushroom Button with Set Screw Securitye Black KR25BH13 KR25BH5 Red KR25RH13 KR25RH5 138.00 Green KR25GH13 KR25GH5 Otherd KR25dH13 KR25dH5 Screw-in Metal Mushroom Button with Set Screw Security Black Red Green
KR4B KR4R KR4R05 KR4G KR4d KR24B KR24R KR24G KR24d 9001KR24BM 9001KR24RM 9001KR24GM
112.00
81.00
90.00
9001KR5B
112.00
81.00
101.00
(KA1)
O X O
O O X
NOTE: To select and order contact blocks, light modules, and accessories, see pages 19-81 through 19-88.
CP1
Discount Schedule
19-63
19
9001KR25BM The universal push button operators contain one each of the following color inserts: black, red, green, yellow, orange, blue and white. See Table 19.172 for color code. Knob has the words Emergency Stop in raised letters highlighted in white for readability. See Table 19.172 for color code. See Table 19.172 for Metal button price adder.
30 mm Push Buttons
142.
86.
188.
129.
KR9R94H13
194.
KR9R94
134.
2 Position 1-1/2 in. (40 mm) Diameter Green 9001KR9RM94 Black Red 2 Position 2-3/8 in. (60 mm) Diameter Green 9001KR9RM95 Non-Illuminated Turn-to-Release Mushroom Operators Description Color With 1 N.O. & 1 N.C. Contact (KA1)
9001KR9GM94
9001KR9GM95
$ Price
$ Price
Red
KR16H13
172.
KR16H2
218.
KR16
113.
illuminated Push-Pull Mushroom Operators Description m Voltage With Red Knob and 2 N.C. Contacts (1 KA3, 1 KA5) KR8P1RH25 KR8PgRH25 KR8PgRH25 With Other Color Knob and 2 N.C. Contacts (1 KA3, 1 KA5) KR8P1fH25 KR8PgfH25 KR8PgfH25 $ Price With Other Color Knob Without Contacts j KR8P1f KR8Pgf KR8Pgf $ Price
19
PUSH BUTTONS AND OPERATOR INTERFACE
p
With Redl Knob With Other Color With Other Color and 1 N.O. & Knob and 1 N.O. 9001KR9P1 Description m Voltage $ Price Knob Without $ Price 1 N.C. Contact & 1 N.C. Contact 1.625 in. Diameter Knob Contacts (KA1) (KA1) For 1-3/8 in. or 2-1/4 in. Diameter Knob m Includes Type KN379 316. KR9P1f 243. 2 Position Illuminated 110120 V, 5060 Hz KR9P1RH13 KR9P1fH13 Legend Plate Marked 316. KR9Pgf 243. Maintained Pull OtherTransformer, LED, Flashing h KR9PgRH13 KR9PgfH13 Pull To Start Push To Stop 257. KR9Pgf 215. Maintained Push OtherFull Voltage, Resistor, Neon i KR9PgRH13 KR9PgfH13 f Choose one color from the Color Codes table below, and insert the color code in Type number. Example: KR9 with a yellow knob = KR9Y g Add the voltage assembly code as chosen from page 19-82. Example: KR8P with a 277 V 5060 Hz voltage = KR8P8 h The knob must be the same color as the LED light module chosen, for example, for a green LED, use a green knob. i On neon light modules, use clear knobs only. j These operators can be ordered complete with contact blocks. For maximum block usage, see page 19-84. Add the H number chosen from page 19-84 to the end of the operator Type number and add the cost of the H number to the operator cost. k KR11UH1 has 1 KA1 (1 N.O., 1 N.C.) and KR12UH1H1 has 2 KA1 (2 N.O., 2 N.C.). l To obtain a red knob with Push Emergency Stop printed on the red knobsubstitute R05 in place of R and add $2.10 to the price. m For 1-3/8 in. or 2-1/4 in. Dia. Knob: a) Order Type -20 or -21 knob from page 19-88. b) Order 9001K54 adapter (no charge)allows Type -20 or -21 knob to fit on push pull operators. Voids UL and NEMA 6 rating. c) Can order assembled operator by adding color code to Type -20 or -21. Example: 9001KR9R would be 9001KR9R20 or 9001KR9R21. No price adder. n See page 19-63 for contact sequences. o See Table 19.175 below.
NOTE: When ordering, add prefix 9001 to the catalog number. To select and order contact blocks, light modules, and accessories, see pages 19-81 through 19-88.
19-64
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.176: Illuminated Momentary Push Button OperatorsUL Types 4, 13/NEMA 4, 13 For use in hazardous locationsSee page 19-83. Legend plate and contact block not included unless otherwise noted.
Description Voltage and Frequency 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc Style Transformer Transformer Full Voltage Transformer or Flashing Full Voltage Resistor or Neonc LED d 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc Full Guard Illuminated Push Button Metal Top Transformer Transformer Full Voltage Transformer or Flashing Full Voltage Resistor or Neon c LED d With Red Color Cap and 1 N.O. and 1 N.C. Contact (KA1) K1L1RH13 K1L7RH13 K1L35RH13 K1LbRH13 K1LbRH13 K1LbRH13 K1LbRH13 K3L1RH13 K3L7RH13 K3L35RH13 K3LbRH13 K3LbRH13 K3LbRH13 K3LbRH13 K2L1RH13 K2L7RH13 K2L35RH13 K2LbRH13 K2LbRH13 K2LbRH13 K2LbRH13 K2L1R20H13 K2L7R20H13 K2L35R20H13 K2LbR20H13 K2LbR20H13 K2LbR20H13 K2LbR20H13 K2L1R21H13 K2L7R21H13 K2L35R21H13 K2LbR21H13 K2LbR21H13 K2LbR21H13 K2LbR21H13 With Green Color Cap and 1 N.O. and 1 N.C. Contact (KA1) K1L1GH13 K1L7GH13 K1L35GH13 K1LbGH13 K1LbGH13 K1LbGH13 K1LbGH13 K3L1GH13 K3L7GH13 K3L35GH13 K3LbGH13 K3LbGH13 K3LbGH13 K3LbGH13 K2L1GH13 K2L7GH13 K2L35GH13 K2LbGH13 K2LbGH13 K2LbGH13 K2LbGH13 K2L1G20H13 K2L7G20H13 K2L35G20H13 K2LbG20H13 K2LbG20H13 K2LbG20H13 K2LbG20H13 K2L1G21H13 K2L7G21H13 K2L35G21H13 K2LbG21H13 K2LbG21H13 K2LbG21H13 K2LbG21H13 $ Price g 231. 231. 198. 231. 198. 198. 231. 231. 231. 198. 231. 198. 231. 231. 217. 217. 184. 217. 184. 184. 217. 217. 217. 184. 217. 184. 184. 217. 217. 217. 184. 217. 184. 184. 217. With Other Color Cap Without Contact Block a K1L1e K1L7e K1L35e K1Lbe K1Lbe K1Lbe K1Lbe K3L1e K3L7e K3L35e K3Lbe K3Lbe K3Lbe K3Lbe K2L1e K2L7e K2L35e K2Lbe K2Lbe K2Lbe K2Lbe $ Price h 184. 184. 138. 184. 138. 138. 184. 184. 184. 138. 184. 138. 138. 184. 153. 153. 125. 153. 125. 125. 153.
9001K1L1
9001K3L1
110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc No Guard Illuminated Push Button Transformer Transformer Full Voltage Transformer or Flashing Full Voltage Resistor or Neon c LED d 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc 1-3/8 in. (35 mm) Illuminated Mushroom Transformer Transformer Full Voltage Transformer or Flashing Full Voltage Resistor or Neon c LED d 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc For other voltages see Table b Transformer Transformer Full Voltage Transformer or Flashing Full Voltage Resistor or Neon c LED d
9001K2L1
9001K2LR20
9001K2LR21
a b c d e f g h
These operators can be ordered complete with contact blocks. For maximum block usage, see page 19-84. Add the H number chosen from page 19-84 to the end of the operator type number and add the cost of the H number to the operator cost. Add the voltage assembly code as chosen from Table 19.228 or 19.229 on page 19-82. Example: K2La with 240 Vac/Vdc = K2L25 On neon light modules, use clear color caps only. The cap must be the same color as the LED light module chosen, e.g., for red LED, use red color cap. Add the color code as chosen from the color cap table. Example: K2L25c with a blue 138 mushroom button = K2L25L20 The only difference between a no guard (K2Lq) operator and mushroom button operator is the color cap. Price includes operator, light module, contact block, and color cap. Price includes operator, light module, and color cap.
NOTE: When ordering, add prefix 9001 to the catalog number. To select and order contact blocks, light modules, and accessories, see pages 19-81 through 19-88.
CP1
Discount Schedule
19-65
19
30 mm Push Buttons
NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.178: 2-Position Selector Switches
Contact Block Required Contact Block Position Quantity and Type KA1 or KA2 or KA3 KA3 KA1 or
Side 2 Side 1
Mount on Side KA1 or KA2 or KA3 Left KA3 #2 or KA2 #2 KA3 #1 or KA2 #1 0 E Cat. No. KS11 KS11* KS11K** KS11BH13 KS11BH1 KS11BH2 KS25 KS25* KS25K2 Cat. No. KS12 KS12* KS12K** KS34 KS34* KS34K1 Cat. No. K12J1 K12J1R K12Jbc K34J1 K34J1R K34Jbc 1 1 D Cat. No. $ Price 42.80 42.80 138.00 106.00 106.00 152.00 71.00 71.00 167.00 71.00 71.00 167.00 $ Price 158.00 167.00 167.00 185.00 197.00 197.00 185.00 197.00 197.00 0 0 1 1 0 1 Right 0 Left 0 Right 1
KA2
KA1 #2
KA3
Operator
Locating Notch
KA1 or KA2
Top View
KA1 #1
Cam (see page 19-69) Non-Illuminated Operators Manual Return a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from Table 19.179 below) Key Operated with E10 Key (Code1,2,3) Operator with Contact Blocks and Standard black knob With 1 KA1 on Side #2 With 1 KA1 on Side #1 With 1 KA1 on Side #1 and 1 KA1 on side #2 Spring Return from Left a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from Table 19.179) Key Operated with E10 Key (Code 2 only)d Spring Return from Right a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from Table 19.179 below) Key Operated with E10 Key (Code 1 only) Illuminated Operators
19
PUSH BUTTONS AND OPERATOR INTERFACE
Manual Return a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer K11J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer K11J1R With Other Color Knob and other voltage Light Module b c K11Jbc Spring Return from Left a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer K25J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer K25J1R With Other Color Knob and other voltage Light Module b c K25Jbc Spring Return from Right a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer With Standard Red Knob, 110-120V 50-60 Hz Transformer With Other Color Knob and other voltage Light Module b c a These operators can be ordered complete with contact blocks. Add the "H code" from page 19-84 as needed for your application. b Add the voltage assembly code as chosen from page 19-82. Example: K25Jb with 208 Vac = K25J3. c Add the knob color code from Table 19.179. For LED, knob color must match LED. d Add the key withdrawal code from Table 19.180.
Table 19.179: Selector Switch Assembly Code and Knob Cat. No.
Color Black Red Green Yellow Blue White Amber Clear Standard Knob c Knob Code B R G Y L W A C Cat. No. B11 R8 G8 Y8 L8 W8 A8 C8 Gloved Hand Knob c Knob Code FB FR FG FY FL FW FA FC Cat. No. B25 R24 G24 Y24 L24 W24 A24 C24 $ Price
Table 19.180:
Code
70
1 2 3
9.90
2 Position
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories, see pages 19-81 through 19-88.
19-66
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.181: 3-Position Selector Switches
Contact Block Required Center Contact Block Position Quantity and Type KA3 KA1 or
Side 2 Side 1
Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right KA3 #2 KA1 #2 or KA2 #2 KA3 KA1 or KA2 KA1 #1 or KA3 #1 KA2 #1 0 1 1 0 0 1 0 1 0 0 1 0 0 0 1 0 1 1 0 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 1 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 1 0
KA2
Operator
Locating Notch
0 0 1
1 0 0
0 0 1
1 0 0
0 1 0
0 0 1
1 0 1
0 0 1
0 1 1
Top View
1 1 0 B Cat. No.
0 0 1 C Cat. No.
1 0 0 M Cat. No. KS402 KS402c KS402Ke $ Price 43.00 53.00 138.00 106.00 106.00 152.00 71.00 81.00 167.00 71.00 81.00 167.00 71.00 81.00 167.00 $ Price 158.00 167.00 158.00 185.00 197.00 167.00 185.00 197.00 167.00 185.00 197.00 167.00
Manual Return, Operator Only (without contact blocks) a Without Knob KS42 KS43 With Knob (select style and color from table 19.168 below) KS42c KS43c Key Operated with E10 Key (Code 4 through 10) e KS42Ke KS43Ke Operator with Contact Blocks and Standard black knob d With 1 KA1 on Side #2 (H13) KS42BH13 KS43BH13 With 1 KA1 on Side #1 (H1) KS42BH1 KS43BH1 With 1 KA1 on Side #1 and 1 KA1 on side #2 (H2) KS42BH2 KS43BH2 Spring Return from Left to Center, Operator Only (without contact blocks) a Without Knob KS62 KS63 With Knob (select style and color from table 19.168 below) KS62c KS63c Key Operated with E10 Key (Code 5, 6 or 9 only)e KS62Ke KS63Ke Spring Return from Right to Center, Operator Only (without contact blocks) a Without Knob KS72 KS73 With Knob (select style and color from table 19.168 below) KS72c KS73c Key Operated with E10 Key (Code 4, 5 or 7 only) KS72Ke KS73Ke Spring Return from Both Sides to Center, Operator Only (without contact blocks) a Without Knob KS52 KS53 With Knob (select style and color from table 19.168 below) KS52c KS53c Key Operated with E10 Key (Code 4, 5 or 7 only) KS52Ke KS53Ke Illuminated Operators Cat. No. Cat. No. K43J1 K43J1R K42Jbc K63J1 K63J1R K62Jbc
KS44BH13 KS45BH13 KS46BH13 KS47BH13 KS49BH13 KS401BH13 KS402BH13 KS44BH1 KS45BH1 KS46BH1 KS47BH1 KS49BH1 KS401BH1 KS402BH1 KS44BH2 KS45BH2 KS46BH2 KS47BH2 KS49BH2 KS401BH2 KS402BH2 KS64 KS64c KS64Ke KS74 KS74c KS74Ke KS54 KS54c KS54Ke Cat. No. K44J1 K44J1R K44Jbc K64J1 K64J1R K64Jbc KS65 KS65c KS65Ke KS75 KS75c KS75Ke KS55 KS55c KS55Ke Cat. No. K45J1 K45J1R K45Jbc K65J1 K65J1R K65Jbc KS66 KS66c KS66Ke KS76 KS76c KS76Ke KS56 KS56c KS56Ke Cat. No. K46J1 K46J1R K46Jbc K66J1 K66J1R K66Jbc KS67 KS67c KS67Ke KS77 KS77c KS77Ke KS57 KS57c KS57Ke Cat. No. K47J1 K47J1R K47Jbc K67J1 K67J1R K67Jbc KS69 KS69c KS69Ke KS79 KS79c KS79Ke KS59 KS59c KS59Ke Cat. No. K49J1 K49J1R K49Jbc K69J1 K69J1R K69Jbc K79J1 K79J1R K79Jbc K59J1 K59J1R K59Jbc KS601 KS601c KS601Ke KS701 KS701c KS701Ke KS501 KS501c KS501Ke Cat. No. K401J1 K401J1R K401Jbc K601J1 K601J1R K601Jbc K701J1 K701J1R K701Jbc K501J1 K501J1R K501Jbc KS602 KS602c KS602Ke KS702 KS702c KS702Ke KS502 KS502c KS502Ke Cat. No. K402J1 K402J1R K402Jbc K602J1 K602J1R K602Jbc K702J1 K702J1R K702Jbc K502J1 K502J1R K502Jbc
Spring Return from Right to Center, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer K72J1 K73J1 K74J1 K75J1 K76J1 K77J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer K72J1R K73J1R K74J1R K75J1R K76J1R K77J1R With Other Color Knob and other voltage Light Module b c K72Jbc K72Jbc K74Jbc K75Jbc K76Jbc K77Jbc Spring Return from Both Sides to Center, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer K52J1 K53J1 K54J1 K55J1 K56J1 K57J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer K52J1R K53J1R K54J1R K55J1R K56J1R K57J1R With Other Color Knob and other voltage Light Module b c K52Jbc K53Jbc K54Jbc K55Jbc K56Jbc K57Jbc a These operators can be ordered complete with contact blocks.00 Add the "H code" from page 19-84 as needed for your application. b Add the voltage assembly code as chosen from page 19-82. Example: K25Jb with 208Vac = K25J3. c Add the knob color code from Table 19.182. For LED, knob color must match LED. d For other color knobs replace the B with knob color code from Table 19.182. e Add the key withdrawal code from table Table 19.183. Example: KS43Ke with key withdrawal in the right position only = KS43K6.
Table 19.182: Selector Switch Assembly Code and Knob Cat. No.
Color Black Red Green Yellow Blue White Amber Clear Standard Knob c Knob Code B R G Y L W A C Cat. No. B11 R8 G8 Y8 L8 W8 A8 C8 Gloved Hand Knob c Knob Code FB FR FG FY FL FW FA FC Cat. No. B25 R24 G24 Y24 L24 W24 A24 C24 $ Price
Table 19.183:
Code 4 5 6 7 8 9 10
Position Left Only Center Only Right Only Left and Center Left and Right Center and Right Left, Center, and Right
70
9.90
70
3 Position
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories, see pages 19-81 through 19-88.
Discount Schedule
19-67
19
Manual Return, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer K42J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer K42J1R With Other Color Knob and other voltage Light Module b c K42Jbc Spring Return from Left to Center, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer K62J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer K62J1R With Other Color Knob and other voltage Light Module b c K62Jbc
30 mm Push Buttons
NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.184: 4-Position Selector Switches
Contact Block Required Contact Block Position Quantity and Type KA1 or KA2 or KA3 KA3 KA1 or
Side 2 Side 1
KA2
KA1 #2
1 0
0 0
0 1
0 0
KA3
Operator
Locating Notch
KA1 or KA2
Top View
KA1 #1
Cam (see page 19-69) Non-Illuminated Operators Manual Return a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from table 19.168 below) Key Operated with E10 Key (Codes 11, 12, 13, 14, 15) Illuminated Operators
H Cat. No. KS88 KS88c KS88Kd Cat. No. $ Price 42.80 53.00 138.00 $ Price 158.00 167.00 158.00
Manual Return a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer KS88J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer KS88J1R With Other Color Knob and other voltage Light Module b c KS88Jbc a These operators can be ordered complete with contact blocks. Add the "H code" from page 19-84 as needed for your application. b Add the voltage assembly code as chosen from page 19-82. Example: K25Jb with 208Vac = K25J3. c Add the knob color code from table 19.185. For LED, knob color must match LED. d Add the key withdrawal code from Table 19.186.
Table 19.185: Selector Switch Assembly Code and Knob Cat. No.
Color Black Red Green Yellow Blue White Amber Clear Standard Knob c Knob Code B R G Y L W A C Cat. No. B11 R8 G8 Y8 L8 W8 A8 C8 Gloved Hand Knob c Knob Code FB FR FG FY FL FW FA FC Cat. No. B25 R24 G24 Y24 L24 W24 A24 C24 $ Price
Table 19.186:
Code
Position
46 47 47
19
PUSH BUTTONS AND OPERATOR INTERFACE
4 Position
2W
NEMA 4, 13
Rear 1 k 1 k For the complete part number, add the suffix from Table 19.188 to the catalog number from Table 19.187. Example: 9001K2105.
Note: Any potentiometer with a shaft 7/8" long and 1/4" diameter may be used with these operators
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories. See pages 19-81 through 19-88.
19-68
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Shown below is a simplified method of selecting a selector switch to meet almost any combination of contact sequences. Step No. 1 Determine the contact sequence(s) required. Set up a target table like the one shown for the example below.
1 0
0 1
Step No. 2 Look for a cam type common to all sequences in Table 19.189, Table 19.190, or Table 19.191. For the example above, Table 19.190 would be used. For the contact sequences A (1 0 0), B (0 1 0) and C (0 0 1) of the example above, cam types F and L are common to all three sequences. Step No. 3 Next, use the cam type common to all the sequences (if several cam types are common, choose one) to find the operator type number. Go to the proper page number as indicated in the table below:
Number of Push Button Line Positions 2 Type K, Type SK, Type KX 3 Type K, Type SK, Type KX 4 Type K, Type SK, Type KX
Page Number 19-66, 19-76, 19-84, 19-91, 19-93 19-67, 19-77, 19-84, 19-91, 19-93 19-68, 19-78, 19-93
If for the example above a manual return operator with a standard black knob is required and: The F cam type is chosen, the operator type number is:
Type KClass 9001 Type KS46B (from page19-67) Type SKClass 9001 Type SKS46B (from page 19-77) Type KXClass 9001 Type KXSDFB (from page 19-93) Type KClass 9001 Type KS401B (from page 19-67) Type SKClass 9001 Type SKS401B (from page 19-77) Type KXClass 9001 Type KXSDLB (from page 19-93)
The L cam type is chosen, the operator type number is: Table 19.191: 4 Position Selector Switch
If you require contact sequence
Step No. 4: Determine the contact blocks required by using the same table in Step No. 2. If, for the example above, the F cam type is chosen:
Use a 9001KA3 mounted on side no. 2 for sequence A (1 0 0). Use a 9001KA3 mounted on side no. 1 for sequence B (0 1 0). Use a 9001KA2 mounted on side no. 1 or 2 for sequence C (0 0 1). Use a 9001KA2 mounted on side no. 2 for sequence A (1 0 0). Use a 9001KA2 mounted on side no. 1 or a 9001KA3 mounted on side no. 2 for sequence B (0 1 0). Use a 9001KA3 mounted on side no. 1 for sequence C (0 0 1).
KA1
= =
KA3
+ +
KA2
CP1
Discount Schedule
19-69
19
One Type KA1 double circuit block can be used in place of one Type KA2 single circuit block plus one Type KA3 single circuit block mounted on the same side.
0 0 0 H (A) KA3 2 1 0 0 H (B) KA2 1 0 1 0 H (C) KA2 2 0 0 1 H (D) KA3 1 0 0 1 H A & D Wired in Parallel 1 0 0 H A & B Wired in Parallel 1 1 0 H B & C Wired in Parallel 0 1 1 H C & D Wired in Parallel 1 1 0 H A, B & C Wired in Parallel 1 1 1 H B, C & D Wired in Parallel 0 1 0 H A & C Wired in Parallel 1 0 1 H B & D Wired in Parallel 1 0 1 H KA5a 2 0 1 1 H KA5a 1 Type KA5 must be the last block on either side. If more than one KA5 is required on either sidecontact your local Square D sales office. Note: For Outline Dimensions see Catalog 9001CT0001
1 0 0 0 1 1 0 0 1 0 1 0 1 1 a
30 mm Push Buttons
Table 19.192: Pilot LightsUL Types 4, 13/NEMA 4 & 13 For use in hazardous locationsSee page 19-83. Legend plates not included.
Description Voltage 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc Style Transformer Transformer Full Voltage With Red With Green Fresnel Color Fresnel Color Cap Cap KP1R31 KP1G31 KP7R31 KP7G31 KP35R31 KP35G31 With Other Color Cap KP1b KP7b KP35b Without $ Price Color Cap $ Price 153. 153. 125. KP1 KP7 KP35 143. 143. 116.
KPaR31 KPaR31
KPaG31 KPaG31
KPab KPab
153. 125.
KPa KPa
143. 116.
KTaR31 KTaR31
KTaG31 KTaG31
KTab KTab
197. 167.
KTa KTa
185. 158.
KTR38R31 KTR35R31
KTR38G31 KTR35G31
KTR38b KTR35b
197. 197.
KTR38 KTR35
185. 185.
See page 19-82.e Full Voltage or Resistor e Remote Test Pilot Light (Glass Color Cap Shown) a Add the voltage assembly code as chosen from Table 19.228 or Table 19.229 on 19-82. EXAMPLE: KTaR31 with 208 Vac red LED = KT37LRR31 b Add the color code as chosen from Table 19.193. EXAMPLE: KP1b with a blue fresnel cap = KP1L31 c The cap must be the same color as the LED light module chosen, e.g., for green LED, use green color cap. d On neon light modules, use clear color caps only. e On remote test pilot lights use only full voltage or resistor voltage assembly codes. Do not choose LED, neon or transformer codes. For AC use only.
KTRaR31
KTRaG31
KTR ab
197.
KTRa
185.
L2
19
PUSH BUTTONS AND OPERATOR INTERFACE
Color b Plastic Fresnel A31 L31 C31 G31 R31 W31 Y31 b Glass A6 L6 C6 G6 R6 W6 Y6
L1
L1
L2 (TEST) C L2 L1 (SIG) M1
STOP
START
(TEST) C LSI
L2 L1 (SIG) M2
(TEST) C M3
L2 L1 (SIG) CR
19-70
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.194: Joy Stick OperatorsUL Types 4, 13/NEMA 4, 13 for use in hazardous locations See page 19-83. Contact blocks and legend plate not included unless noted.
Operator Operator $ Price Without Contacts a $ Price With Contacts Without Latch K71H7 K71 Momentary Contact Spring Return to Center With Latch K70H7 K70 3 Position 326. 252. Center Off Without Latch K73H7 K73 Maintained Contact With Latch K72H7 K72 Without Latch K31H8 K31 Momentary Contact Spring Return to Center With Latch K30H8 K30 3 Position 326. 252. Center Off Without Latch K33H8 K33 Maintained Contact With Latch K32H8 K32 Without Latch K35H2 K35 Momentary Contact Spring Return to Center With Latch K34H2 K34 5 Position 435. 309. Center Off Without Latch K37H2 K37 Maintained Contact With Latch K36H2 K36 These operators can be ordered complete with contact blocksa total of four (4) contact blocks can be used. Add the H number chosen from page 19-84 to the operator type number and add the cost of the H number to the operator cost. Description
Without Latch
With Latch
For use in hazardous locationsSee page 19-83. Legend plate and contact block not included. Inserts are field convertible. For colors not listed, order operator without insert, plus separate color insert from page 19-88. Up to two Type KA contact blocks can be mounted in tandem (total of four blocks). Selector push buttons cannot be illuminated. Table 19.196: Selector Push Button OperatorsUL Types 4, 13/NEMA 4, 13
Contact Block Required Two Position Operators 0Contact Open Left FD 0 0 0 1 0 0 #1 1 KA1 Cam c Color Insert 0 1 P Right FD 1 0 0 1 1 1 0 0 Left FD 0 0 0 1 0 0 0 1 R Right FD 1 0 0 0 1 0 0 0 Left FD 0 0 0 1 1 1 0 0 S Type KQ13 KQ13B 1Contact Closed Right FD 1 1 0 0 0 0 0 1 Left FD 1 1 0 0 1 0 0 1 T Type KQ14 KQ14B FD 1 0 0 1 1 1 0 0 FFree Left FD 1 0 0 1 1 1 0 0 Y Type KQ15 KQ15B $ Price 80. 81. DDepressed Right FD 0 0 Right
0 0 0 1
Type Type KQ11 KQ12 KQ11B KQ12B Order color inserts from page 19-88. Cams are not interchangeable.
For use in hazardous locations. See page 19-83. Key operated push buttons are used wherever unauthorized use of a push button is discouraged. Examples are locking a Start push button in the extended position or locking a Stop push button in the depressed position. The operator can also be locked in the flush positionholding all contacts open. Up to two Type KA contact blocks can be mounted in tandem (total of four blocks). Legend Plate and Contact Block Not Included (X = locked position) d Table 19.197: Key Operated Push Button UL Types 4, 13/NEMA 4, 13
Lockable Positions Type $ Price Extended Flush Depressed X KR131 X KR132 Push button operable only with key in lock. Key is removable in locked position only. X KR133 X X X KR137 X KR141 125. Push button operable with or without key in lock. Push button can be locked with key X KR142 only. Key removable in both locked or unlocked position. X KR143 X X X KR147 To lock the unit, rotate the key with the button in the extended position. Then, push the X KR152 button to lock it in the position indicated at right. Key is removable only in this position. X KR153 d All key operated push buttons are furnished as standard with Square D no. E10 key change. See catalog 9001CT0001 for other key changes. Description
CP1
Discount Schedule
19-71
19
30 mm Push Buttons
Table 19.198: Illuminated and Non-Illuminated Dual Operators Meets UL Type 13/NEMA 13 and UL Type 6/NEMA 6, which UL and NEMA consider an equivalent to UL Type 4/NEMA 4. For use in hazardous locationsSee page 19-83. Legend plate and contact blocks not included unless otherwise noted.
Description Momentary Dual Function Momentary Interlocked Dual Function Maintained Interlocked Dual Function Description Both Buttons Maintained Interlocked Assembly One Button Momentary One Button Maintained Interlocked Assembly Color Universal a Green-Red Other b Universala Green-Red Other b Universal a Green-Red Other b Color Universal c Other d Universal c Otherd With 2 N.O. Contacts (2 KA2) KR6UH7 KR6GRH7 KR6bH7 KR67UH7 KR67GRH7 KR67bH7 KR7UH7 KR7GRH7 KR7bH7 With 1 N.O. & 1 N.C. Contact (KA2, KA3) KR6UH37 KR6GRH37 KR6bH37 KR67UH37 KR67GRH37 KR67bH37 KR7UH37 KR7GRH37 KR7bH37 Contacts (KA1) KR11UH1 KR11dH1 KR12UH1H1 KR12dH1H1 $ Price Without Contacts d KR6U KR6GR KR6b KR67U KR67GR KR67b KR7U KR7GR KR7b Without Contacts d KR11U KR11d KR12U KR12d $ Price
9001KR7U
273.00
162.00
9001KR11U
a b c d
Universal for KR6, KR67, KR7 includes 2 inserts each of black, red and green. Choose one color for each button. R = red, G = green, B = Black. Example: A KR6 with left red and right black = KR6RB Universal for KR11, KR12 includes 2 each of black, red, green, yellow, orange, blue, white. Choose one color for each button from table and insert color code in type number. Example: A KR11 with top button gray and bottom button orange = KR11ES
19
Rocker Arm Operating Lever 9001K50 PUSH BUTTONS AND OPERATOR INTERFACE Push-on Push-off Module 9001K85 Time Delay Push Button 9001KRD
Allows two standard push buttons to be operated independently of each other. Price does not include push buttons or legend plates. Order push buttons and legend plates from pages 19-63, 19-85, and 19-86specify which marking is to be inverted.
KRD2UH1
KRD3UH1
277.00
Table 19.204: Wobble Stick For easy operation of any standard push button.
Type K8 $ Price 42.80
KRD1UH2
KRD2UH2
KRD3UH2
514.00
Timed Contact 2 N.O. and 2 N.C. Timing period is adjustable from 0.1 second to 60 seconds and begins after button has been released. Devices include a pack of seven color inserts for color coding the push button. See 19-88 for Universal color insert. Contacts are quick makequick break. Note: When mounted in top or bottom hole of a Type K enclosure, device requires one additional space below or above operator. When mounted other than in top or bottom hole, device may require two additional spaces, one above and one below operator. Closing plates must be installed on unused holes.
19-72
CP10
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.205: Non-Illuminated Momentary Push Button OperatorsUL Types 4, 4X, 13/NEMA 4, 4X, 13 For use in hazardous locationsSee page 19-83. Contact blocks and legend plate not included unless otherwise noted.
Description Color Black Red Green Universal a 9001SKR1B Full Guard Other b Black Red Green Universal a 9001SKR3B No Guard Other b Black Red Green Universal a 9001SKR2B Extended Guard Other b Operator with 1 N.O. and 1 N.C. Contact (KA1) SKR1BH13 SKR1RH13 SKR1GH13 SKR1UH13 SKR1bH13 SKR3BH13 SKR3RH13 SKR3GH13 SKR3UH13 SKR3bH13 SKR2BH13 SKR2RH13 SKR2GH13 SKR2UH13 SKR2b Operator with $ Price 1 N.O. Contact (KA2) 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 89.00 SKR1BH5 SKR1RH5 SKR1GH5 SKR1UH5 SKR1bH5 SKR3BH5 SKR3RH5 SKR3GH5 SKR3UH5 SKR3bH5 SKR2BH5 SKR2RH5 SKR2GH5 SKR2UH5 SKR2bH5 Operator with 1 N.C. Contact (KA3) SKR1BH6 SKR1RH6 SKR1GH6 SKR1UH6 SKR1bH6 SKR3BH6 SKR3RH6 SKR3GH6 SKR3UH6 SKR3bH6 SKR2BH6 SKR2RH6 SKR2GH6 SKR2UH6 SKR2bH6 Operator Only $ Price No Contacts e 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 66.00 SKR1B SKR1R SKR1G SKR1U SKR1b SKR3B SKR3R SKR3G SKR3U SKR3b SKR2B SKR2R SKR2G SKR2U SKR2b $ Price 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60 38.60
a b c d e
NOTE: When ordering, add prefix 9001 to the catalog number. To select and order contact blocks, light modules, and accessories, see pages 19-81 through 19-88.
CP1
Discount Schedule
19-73
19
Snap-In Mushroom Button Black SKR4BH13 138.00 SKR4BH5 Red SKR4RH13 138.00 SKR4RH5 Red c SKR4R05H13 142.00 SKR4R05H5 Green SKR4GH13 138.00 SKR4GH5 Other d SKR4dH13 138.00 SKR4dH5 Screw-On Mushroom Button with Set Screw Security Black SKR24BH13 138.00 SKR24BH5 Red SKR24RH13 138.00 SKR24RH5 Green SKR24GH13 138.00 SKR24GH5 Other d SKR24dH13 138.00 SKR24dH5 Snap-In Mushroom Button Black SKR5BH13 138.00 SKR5BH5 Red SKR5RH13 138.00 SKR5RH5 Red c SKR5R05H13 142.00 SKR5R05H5 Green SKR5GH13 138.00 SKR5GH5 Other d SKR5dH13 138.00 SKR5dH5 Screw-On Mushroom Button with Set Screw Security Black SKR25BH13 138.00 SKR25BH5 Red SKR25RH13 138.00 SKR25RH5 Green SKR25GH13 138.00 SKR25GH5 Other d SKR25dH13 138.00 SKR25dH5
SKR4BH6 SKR4RH6 SKR4R05H6 SKR4GH6 SKR4dH6 SKR24BH6 SKR24RH6 SKR24GH6 SKR24dH6 SKR5BH6 SKR5RH6 SKR5R05H6 SKR5GH6 SKR5dH6
112.00 112.00 119.00 112.00 112.00 112.00 112.00 112.00 112.00 112.00 112.00 119.00 112.00 112.00
SKR4B SKR4R SKR4R05 SKR4G SKR4d SKR24B SKR24R SKR24G SKR24d SKR5B SKR5R SKR5R05 SKR5G SKR5d
81.00 81.00 86.00 81.00 81.00 81.00 81.00 81.00 81.00 81.00 81.00 86.00 81.00 81.00
30 mm Push Buttons
9001SKR9R Non-Illuminated
1-5/8 in. Diameter Knob Includes Type KN179WP Legend Plate Marked Pull To Start Push To Stop
2 Positionf Red Maintained PullMaintained Push Green Other g SKR9RH13 SKR9GH13 SKR9gH13 188. SKR9R SKR9G SKR9g 129.
Non-Illuminated Turn-to-Release Mushroom Operators Description Color With 1 N.O. Contact (KA1) With 2 N.O. /2 $ Price N.C. Contacts (2 KA1) $ Price Without Contacts $Price
Red
SKR16H13
172.
SKR16H2
218.
SKR16
113.
9001SKR16H2
Illuminated Push-Pull Mushroom Operators Illuminated Description 3 POSITION 110120 V, 5060 Hz Momentary Pull- OtherTransformer, LED, Maintained NeutralFlashing i Momentary Push m OtherFull Voltage, Resistor, Neon j Description 2 POSITION Voltage SKR8P1RH25 SKR8PhRH25 SKR8PhRH25 SKR8P1gH25 SKR8PhgH25 SKR8PhgH25 267. 215. SKR8P1g SKR8Phg SKR8Phg 201. 171. $ Price Voltage With Red Knob and 2 N.C. Contacts (1 KA3, 1 KA5) With Other Color Knob and 2 N.C. Contacts $ Price With Other Color Knob Without Contacts k $ Price
19
PUSH BUTTONS AND OPERATOR INTERFACE 9001SKR9P1 Illuminated
1-5/8 in. Diameter Knob Includes Type KN179WP Legend Plate Marked Pull to Start Push To Stop f g h i j k l m (KA1) KA3 KA2
With Red f Knob and With Other Color With Other Color 1 N.O. & 1 N.C. Knob and 1 N.O. & 1 $ Price Knob Without Contact (KA1) N.C. Contact (KA1) Contacts SKR9P1RH13 SKR9PhRH13 SKR9PhRH13 SKR9P1gH13 SKR9PhgH13 SKR9PhgH13 316. SKR9P1g SKR9Phg SKR9Phg
243.
257.
215.
To obtain a red knob with Push Emergency Stop printed on the red knobsubstitute R05 in place of R and add $2.10 to the price. Choose one color from Table 19.208 and insert the color code in the Type number. Example: SKR9g with a yellow knob = SKR9Y Add the voltage assembly code as chosen from page 19-82. Example: SKR8Ph with 277 V 5060 Hz = SKR8P8 The knob must be the same color as the LED light module chosen; e.g., for green LED, use green knob. On neon light modules, use clear knobs only. These operators can be ordered complete with contact blocks. For maximum block usage, see page 19-84. Add the H number chosen from page 19-84 to the end of the operator type number and add the cost of the H number to the operator cost. SKR11UH1 has 1 KA1(1 N.O., 1 N.C.) and SKR12UH1H1 has 2 KA1 (2 N.O., 2 N.C.). For positions, refer to Tables 19.209 and 19.210.
NOTE: When ordering, add prefix 9001 to the catalog number. To select and order contact blocks, light modules, and accessories, see pages 19-81 through 19-88.
19-74
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.211: Illuminated Push Button OperatorsUL Types 4, 4X, 13/NEMA 4, 4X, 13 For use in hazardous locationsSee page 19-83. Legend plate not included unless otherwise noted.
Description Voltage and Frequency 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc Full Guard Illuminated Push Button Style Transformer Transformer Full Voltage Transformer, Flashing Full Voltage Resistor, Neon c LED e 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc No Guard Illuminated Push Button Transformer Transformer Full Voltage Transformer, Flashing Full Voltage Resistor, Neon c LEDe 9001SK2L1 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc 1-3/8 in. (35 mm) Illuminated Mushroom Transformer Transformer Full Voltage Transformer, Flashing Full Voltage Resistor, Neon c LED e 9001SK2L1R20 110120 V, 5060 Hz 220240 V, 5060 Hz 2428 Vac/Vdc Transformer Transformer Full Voltage Transformer, Flashing Full Voltage Resistor, Neon c SK2L1R21H13 SK2L7R21H13 SK2L35R21H13 SK2LbR21H13 SK2LbR21H13 SK2LbR21H13 SK2L1G21H13 SK2L7G21H13 SK2L35G21H13 SK2LbG21H13 SK2LbG21H13 SK2LbG21H13 217. 217. 184. 217. 184. 184. SK2L1R20H13 SK2L7R20H13 SK2L35R20H13 SK2LbR20H13 SK2LbR20H13 SK2LbR20H13 SK2LbR20H13 SK2L1G20H13 SK2L7G20H13 SK2L35G20H13 SK2LbG20H13 SK2LbG20H13 SK2LbG20H13 SK2LbG20H13 217. 217. 184. 217. 184. 184. 217. With Other Color With Red Color Cap and With Green Color Cap and Cap Without 1 N.O. and 1 N.C. Contact 1 N.O.and 1 N.C. Contact $ Price g Contact Blocks $ Price h (KA1) (KA1) a SK1L1RH13 SK1L7RH13 SK1L35RH13 SK1LbRH13 SK1LbRH13 SK1LbRH13 SK1LbRH13 SK2L1RH13 SK2L7RH13 SK2L35RH13 SK2LbRH13 SK2LbRH13 SK2LbRH13 SK2LbRH13 SK1L1GH13 SK1L7GH13 SK1L35GH13 SK1LbGH13 SK1LbGH13 SK1LbGH13 SK1LbGH13 SK2L1GH13 SK2L7GH13 SK2L35GH13 SK2LbGH13 SK2LbGH13 SK2LbGH13 SK2LbGH13 231. 231. 198. 231. 198. 198. 231. 217. 217. 184. 217. 184. 184. 217. SK1L1 SK1L7 SK1L35 SK1L b SK1L b SK1L b SK1L bd SK2L1 SK2L7 SK2L35 SK2L b SK2L b SK2L b SK2L bd 158. 158. 129. 158. 129. 129. 158. 143. 143. 116. 143. 116. 116. 143.
9001SK1L1
Order SK2Lbdf
Order SK2Lbdf
a b c d e f g h
NOTE: When ordering, add prefix 9001 to the catalog number. To select and order contact blocks, light modules, and accessories, see pages 19-81 through 19-88.
CP1
Discount Schedule
19-75
19
LED e SK2LbR21H13 SK2LbG21H13 217. 9001SK2L1R21 These operators can be ordered complete with contact blocks. For maximum block usage, see page 19-84. Add the H number chosen from page 19-84 to the end of the operator type number and add the cost of the H number to the operator cost. Add the voltage assembly code as chosen from page 19-82. EXAMPLE: SK2Lb with 240 Vac/Vdc = SK2L25. On neon light modules, use clear color caps only. The cap must be the same color as the LED light module chosen e.g., for red LED, use red color cap. Add the color code as chosen from the color cap table below. EXAMPLE: SK2L25e with a blue 1-3/8 in. mushroom button = SK2L25L20. The only difference between a no guard (SK2L) operator and mushroom button operator is the color cap. Price includes operator, light module, contact blocks and color cap. Price includes operator, light module and color cap.
30 mm Push Buttons
NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.213: 2-Position Selector Switches
Contact Block Required Quantity and Type KA1 or KA2 or KA3 KA3 KA1 or
Side 2 Side 1
1Contact Closed 0Contact Open Mount on Side KA1 or KA2 or KA3 KA3 #2 or KA2 #2 KA3 #1 or KA2 #1 0 E Type SKS11 SKS11c SKS11BH13 SKS11BH1 SKS11BH2 SKS25 SKS25c Type 1 1 D Type SKS12 SKS12c SKS34 SKS34c Type $ Price 42.80 53.00 106.00 106.00 152.00 71.00 81.00 71.00 81.00 $ Price 158.00 167.00 167.00 185.00 197.00 197.00 185.00 197.00 197.00 0 0 1 1 0 1 0 0 1
Left 1
Right 0
Left 0
Right 1
KA2
KA1 #2
KA3 KA1
Operator
Locating
or
KA2
KA1 #1
Top View Cam (see page 19-69) Non-Illuminated Operators Manual Return a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from Table 19.166 below) Operator with Contact Blocks and Standard black knob With 1 KA1 on Side #2 With 1 KA1 on Side #1 With 1 KA1 on Side #1 and 1 KA1 on side #2 Spring Return from Left a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from Table 19.166 below) Spring Return from Right a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from Table 19.166 below) Illuminated Operators
Manual Return a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer SK11J1 SK12J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK11J1R SK12J1R With Other Color Knob and other voltage Light Module b c SK11Jbc SK12Jbc Spring Return from Left a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer SK25J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK25J1R With Other Color Knob and other voltage Light Module b c SK25Jbc Spring Return from Right a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer SK34J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK34J1R With Other Color Knob and other voltage Light Module b c SK34Jbc a These operators can be ordered complete with contact blocks. Add the "H code" from page 19-84 as needed for your application. b Add the voltage assembly code as chosen from page 19-82. Example: K25Jb with 208Vac = K25J3 c Add the knob color code from Table 19.214. For LED, knob color must match LED.
19
PUSH BUTTONS AND OPERATOR INTERFACE
Table 19.214: Selector Switch Assembly Code and Knob Cat. No.
Color Black Red Green Yellow Blue White Amber Clear Standard Knob c Knob Code B R G Y L W A C Cat. No. B11 R8 G8 Y8 L8 W8 A8 C8 Gloved Hand Knob c Knob Code FB FR FG FY FL FW FA FC Cat. No. B25 R24 G24 Y24 L24 W24 A24 C24 $ Price
70
9.90
2 Position
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories. See pages 19-81 through 19-88.
19-76
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.215: 3-Position Selector Switches
CONTACT BLOCK REQUIRED Contact Block Position Quantity and Type KA3 KA1 or
Side 2 Side 1
1 Contact Closed Mount on Side KA3 #2 1 Center Center Center Center Center
KA2
KA3
Operator
Locating Notch
KA1 or KA2
Top View
KA1 or #1 KA2 #1 1 1 0 0 0 1 0 1 0 0 1 0 0 0 1 1 0 0 0 1 0 0 1 0 1 0 0
B Type
C Type
D Type
E Type
F Type
G Type
J Type
L Type
M Type $ Price 42.80 53.00 106.00 106.00 152.00 71.00 81.00 71.00 81.00 71.00 81.00 $ Price 158.00 167.00 167.00 185.00 197.00 197.00 185.00 197.00 197.00 185.00 197.00 197.00
Manual Return, Operator Only (without contact blocks) a Without Knob SKS42 SKS43 SKS44 SKS45 SKS46 SKS47 SKS49 SKS401 SKS402 With Knob (select style and color from table 19.168 below) SKS42c SKS43c SKS44c SKS45c SKS46c SKS47c SKS49c SKS401c SKS402c Operator with Contact Blocks and Standard black knob d With 1 KA1 on Side #2 (H13) SKS42BH13 SKS43BH13 SKS44BH13 SKS45BH13 SKS46BH13 SKS47BH13 SKS49BH13 SKS401BH13 SKS402BH13 With 1 KA1 on Side #1 (H1) SKS42BH1 SKS43BH1 SKS44BH1 SKS45BH1 SKS46BH1 SKS47BH1 SKS49BH1 SKS401BH1 SKS402BH1 With 1 KA1 on Side #1 and 1 KA1 on side #2 (H2) SKS42BH2 SKS43BH2 SKS44BH2 SKS45BH2 SSKS46BH2 SKS47BH2 SKS49BH2 SKS401BH2 SKS402BH2 Spring Return from Left to Center, Operator Only (without contact blocks) a Without Knob SKS62 SKS63 SKS64 SKS65 SKS66 SKS67 SKS69 SKS601 SKS602 With Knob (select style and color from table 19.168 below) SKS62c SKS63c SKS64c SKS65c SKS66c SKS67c SKS69c SKS601c SKS602c Spring Return from Right to Center, Operator Only (without contact blocks) a Without Knob SKS72 SKS73 SKS74 SKS75 SKS76 SKS77 SKS79 SKS701 SKS702 With Knob (select style and color from table 19.168 below) SKS72c SKS73c SKS74c SKS75c SKS76c SKS77c SKS79c SKS701c SKS702c Spring Return from Both Sides to Center, Operator Only (without contact blocks) a Without Knob SKS52 SKS53 SKS54 SKS55 SKS56 SKS57 SKS59 SKS501 SKS502 With Knob (select style and color from table 19.168 below) SKS52c SKS53c SKS54c SKS55c SKS56c SKS57c SKS59c SKS501c SKS502c Illuminated Operators Type Type Type Type Type Type Type SK49J1 SK49J1R SK49Jbc SK69J1 SK69J1R SK69Jbc SK79J1 SK79J1R SK79Jbc SK59J1 SK59J1R SK59Jbc Type SK401J1 SK401J1R SK401Jbc SK601J1 SK601J1R SK601Jbc SK701J1 SK701J1R SK701Jbc SK501J1 SK501J1R SK501Jbc Type SK402J1 SK402J1R SK402Jbc SK602J1 SK602J1R SK602Jbc SK702J1 SK702J1R SK702Jbc SK502J1 SK502J1R SK502Jbc
Table 19.216: Selector Switch Assembly Code and Knob Cat. No.
Color Black Red Green Yellow Blue White Amber Clear Standard Knob c Knob Code B R G Y L W A C Cat. No. B11 R8 G8 Y8 L8 W8 A8 C8 Gloved Hand Knob c Knob Code FB FR FG FY FL FW FA FC Cat. No. B25 R24 G24 Y24 L24 W24 A24 C24 $ Price
70
9.90
70
3 Position
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories. See pages 19-81 through 19-88.
Discount Schedule
19-77
19
Manual Return, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer SK42J1 SK43J1 SK44J1 SK45J1 SK46J1 SK47J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK42J1R SK43J1R SK44J1R SK45J1R SK46J1R SK47J1R With Other Color Knob and other voltage Light Module b c SK42Jbc SK43Jbc SK44Jbc SK45Jbc SK46Jbc SK47Jbc Spring Return from Left to Center, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer SK62J1 SK63J1 SK64J1 SK65J1 SK66J1 SK67J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK62J1R SK63J1R SK64J1R SK65J1R SK66J1R SK67J1R With Other Color Knob and other voltage Light Module b c SK62Jbc SK63Jbc SK64Jbc SK65Jbc SK66Jbc SK67Jbc Spring Return from Right to Center, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer SK72J1 SK73J1 SK74J1 SK75J1 SK76J1 SK77J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK72J1R SK73J1R SK74J1R SK75J1R SK76J1R SK77J1R With Other Color Knob and other voltage Light Module b c SK72Jbc SK73Jbc SK74Jbc SK75Jbc SK76Jbc SK77Jbc Spring Return from Both Sides to Center, Operator Only (without contact blocks) a Without Knob, 110-120V 50-60 Hz Transformer SK52J1 SK53J1 SK54J1 SK55J1 SK56J1 SK57J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK52J1R SK53J1R SK54J1R SK55J1R SK56J1R SK57J1R With Other Color Knob and other voltage Light Module b c SK52Jbc SK53Jbc SK54Jbc SK55Jbc SK56Jbc SK57Jbc a These operators can be ordered complete with contact blocks. Add the "H code" from page 19-84 as needed for your application. b Add the voltage assembly code as chosen from page 19-82. Example: K25Jb with 208Vac = K25J3. c Add the knob color code from Table 19.216. For LED, knob color must match LED. d For other color knobs replace the B with knob color code from Table 19.216.
30 mm Push Buttons
NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.217: 4-Position Selector Switches
CONTACT BLOCK REQUIRED Contact Block Position Quantity and Type KA3 KA1 or
Side 2 Side 1
1 Contact Closed 0 Contact Open Mount on Side KA3 #2 KA1 #2 or KA2 #2 KA3 #1 or KA2 #1 0 1 H Type SKS88 SKS88c Type $ Price 42.80 52.65 $ Price 158.00 167.00 167.00 0 0 0 0 1 0 1 0 0 0
KA2
KA3
Operator
Locating Notch
Top View
Cam (see page 19-69) Non-Illuminated Operators Manual Return a, Operator Only (without contact blocks) Without Knob With Knob (select style and color from table 19.168 below) Illuminated Operators
Manual Return a, Operator Only (without contact blocks) Without Knob, 110-120V 50-60 Hz Transformer SK88J1 With Standard Red Knob, 110-120V 50-60 Hz Transformer SK88J1R With Other Color Knob and other voltage Light Module b c SK88Jbc a These operators can be ordered complete with contact blocks. Add the "H code" from page 19-84 as needed for your application. b Add the voltage assembly code as chosen from page 19-82. Example: K25Jb with 208Vac = K25J3 c Add the knob color code from Table 19.218. For LED, knob color must match LED Standard Knob c Knob Code B R G Y L W A C Cat. No. B11 R8 G8 Y8 L8 W8 A8 C8 Gloved Hand Knob c Knob Code FB FR FG FY FL FW FA FC Cat. No. B25 R24 G24 Y24 L24 W24 A24 C24
$ Price
46 47 47
9.90
19
PUSH BUTTONS AND OPERATOR INTERFACE
4 Position
2W
NEMA 4, 13
Rear 1 k 1 k For the complete part number, add the suffix from Table 19.219 to the catalog number from Table 19.218. Example: 9001K2105.
Note: Any potentiometer with a shaft 7/8 in. long and 1/4 in. diameter may be used with these operators
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories. See pages 19-81 through 19-88.
19-78
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Table 19.220: Pilot LightsUL Types 4, 4X, 13/NEMA 4, 4X, 13 For use in hazardous locationsSee page 19-83. Legend plate not included.
Description Voltage 110120 V, 5060 Hz 220240 V, 5060 Hz Standard Pilot Light 2428 Vac/Vdc (Fresnel color cap shown) For other voltages see Table a 9001SKP1 110120 V, 5060 Hz Push-To-Test Pilot Light 2428 Vac/Vdc (Fresnel color cap shown) For other voltages see Table a 120 Vac Only Remote Test 2428 Vac Only Pilot Light (Fresnel color cap shown) For other voltages see Tables abe 220240 V, 5060 Hz Style Transformer Transformer Full Voltage Transformer, Flashing or LEDc Full Voltage, Neon or Resistord Transformer Transformer Full Voltage Transformer, Flashing or LEDc Full Voltage, Neon or Resistord Resistor Full Voltage With Red With Green Without Fresnel Color Fresnel Color With Other $ Price Color Cap $ Price Color Cap Cap Cap SKP1R31 SKP7R31 SKP35R31 SKPaR31 SKPaR31 SKT1R31 SKT7R31 SKT35R31 SKTaR31 SKTaR31 SKP1G31 SKP7G31 SKP35G31 SKPaG31 SKPaG31 SKT1G31 SKT7G31 SKT35G31 SKTaG31 SKTaG31 SKP1b SKP7b SKP35b SKPab SKPab SKT1b SKT7b SKT35b SKTab SKTab 153. 153. 125. 125. 125. 197. 197. 167. 197. 197. SKP1 SKP7 SKP35 SKPa SKPa SKT1 SKT7 SKT35 SKTa SKTa 143. 143. 116. 116. 116. 185. 185. 158. 158. 158. 185. 185.
9001SKT1
a b c d e
Full Voltage or Resistor SKTRaR31 SKTRaG31 SKTRab 197. SKTRa 185. e 9001SKTR38 Add the voltage assembly code as chosen from Table 19.228 or Table 19.229 on page 19-82. EXAMPLE: SKTqR31 with 208 Vac red LED voltage = SKT37LRR31. Add the color code as chosen from the color cap table below. EXAMPLE: SKP1c with a blue fresnel cap = SKP1L31. The cap must be the same color as the LED light module chosen, e.g., for a green LED, use a green color cap. On neon light modules, use clear color caps only. Use only full voltage or resistor voltage assembly codes on remote test pilot lights. Do not choose LED, neon or transformer codes. For AC use only.
A9 L9 C9 G9 R9 W9 Y9
TEST BUTTON
L2 (TEST) C L2 L1 (SIG) M1
STOP
START
(TEST) C M L2 LSI
L2 L1 (SIG) M2
R
C Test L1 M3 (TEST) C L2 L1 (SIG) CR
NOTE: When ordering, add prefix 9001 to the catalog number. To select and order contact blocks, light modules, and accessories, see pages 19-81through 19-88.
CP1
Discount Schedule
19-79
19
30 mm Push Buttons
Table 19.222: Multifunction OperatorsUL Types 4, 4X, 13/NEMA 4, 4X, 13 For use in hazardous locationsSee page 19-83. Legend plate and contact blocks not included unless otherwise noted.
Interlocked Assembly Description Interlocked Assembly Both Buttons Maintained Interlocked Assembly One Button Momentary Color Universal a Other b Universal a Contacts SKR11UH1 SKR11bH1 SKR12UH1H1 $ Price 178. Without Contacts SKR11U SKR11b SKR12U $ Price 120.
162.
9001SKR11U
a b Universal for SKR11,12 includes 2 each of black, red, green, yellow, orange, blue, white. Choose one color for each button from table and insert color code in type number, top button first. Example: An SKR11 with top button gray and bottom button orange = SKR11ES
19
PUSH BUTTONS AND OPERATOR INTERFACE
19-80
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
The Class 9001 Type KA contact blocks are Fingersafe contact blocks (meeting VDE 0106 Part 100). They have one screw mounting and captive (backed out) plus/minus terminal screws. These contact blocks are double-break, direct-acting contacts. Because of the wiping action of these contacts, they are suitable for use with programmable controllers. All contact blocks listed below accept up to 2 #12#24 AWG solid or stranded wires. Recommended tightening torque for screw terminals is 7 lb-in. Table 19.223: Standard Contact Blocks
Description Symbol Type $ Price
Symbol
Contact Blocks with Binder Head Screws (not Fingersafe) Type KA21 KA22 KA23 Quantityb 25Up 25Up 25Up $ Price 42.80 21.50 21.50
Gold Flashed Contacts with Standard Pressure Wire Terminals Type KA31 KA32 KA33 $ Price 71.00 35.60 35.60
KA1
42.80
25Up
42.80
KA34
71.00
21.50
KA25 25Up 21.50 KA35 35.60 N.C. Contact Late Opening b Minimum order quantity is 25. The price represents one individual contact block.
42.80
Terminals that accept ring tongue/fork tongue connectors Short single circuit contact blocks (0.75" deep vs. 0.97" deep on the Fingersafe) Same as old style Series G product available prior to March, 1989. For assembled operators, use form Y238 (add to catalog number as suffix, for example: 9001KRU1H13Y238)
(Clear Cover)
21.50
KA1G
KA4G
42.80
(Red Cover)
KA2G
21.50
KA5G
21.50
KA4 KA1 Overlapping a Order One N.O. Contact of KA4 closes Type KA4 and One 64.30 before N.C. Contact of KA5 Type KA5 Opens KA4 KA5 a For push buttons or two-position selector switches only. For sequencing or overlapping contacts on other operators, refer to catalog 9001CT0001.
35.60
AC Inductive (NEMA / UL Type A600) 35% Power Factor Make Amperes 120 240 480 600 60 30 15 12 VA Break Amperes 6.0 3.0 1.5 1.2 VA Continuous Carrying Amperes Resistive 75% Power Factor Make, Break and Continuous Amperes
DC Inductive and Resistive (NEMA Q600) Make and Break KA1 125 250 600 0.55 0.27 0.10 KA2 KA3 0.55 0.27 0.10 KA4 KA5 KA6 Continuous Carrying Amperes
Volts
7200
720
10
10
2.5
CP1
Discount Schedule
19-81
19
Table 19.227: Maximum Current Ratings for Control Circuit ContactsTypes KA1KA6, KA21KA25, KA31KA35, KA1GKA6G
(Green Cover)
30 mm Push Buttons
With neon type light modules, use a clear color cap only. With LED light modules, use either a clear color cap or a cap the same color as the LED.
Table 19.228: Standard Light Modules for Types K, SK, and KX Control Units b
Light Module Voltage All 6 Vac/Vdc 6 Vac/Vdc 6 Vac/Vdc 6 Vac/Vdc 1214 Vac/Vdc 1214 Vac/Vdc 1214 Vac/Vdc 1214 Vac/Vdc 18 Vac/Vdc 2428 Vac/Vdc 2428 Vac/Vdc 2428 Vac/Vdc 2428 Vac/Vdc 2428 Vac/Vdc 2428 Vac/Vdc 48 Vac/Vdc 110120 V, 5060 Hz 110120 V, 5060 Hz 110120 V, 5060 Hz 110120 V, 5060 Hz 110120 V, 5060 Hz 120 Vac/Vdc 120 Vac/Vdc 120 Vac/Vdc 120 Vac/Vdc 120 Vac/Vdc 120 Vac/Vdc 120 Vac/Vdc 120 Vac/Vdc 208220 V, 5060 Hz 208220 V, 5060 Hz 208220 V, 5060 Hz 208220 V, 5060 Hz 220240 V, 5060 Hz 220240 V, 5060 Hz 220240 V, 5060 Hz 220240 V, 5060 Hz 240 Vac/Vdc 240 Vac/Vdc 277 V, 5060 Hz 380480 V, 5060 Hz 480 Vac/Vdc 550600 V, 5060 Hz a b Description Full Voltage (without Bayonet Base Lamp) Full Voltage LED Red LED Green LED Yellow Full Voltage LED Red LED Green LED Yellow Resistor Full Voltage LED Red LED Green LED Yellow LED White LED Blue Full Voltage LED Red LED Green LED Yellow Transformer Flashing Resistor Full Voltage Neon a LED Red LED Green LED Yellow LED White LED Blue Transformer LED Red LED Green LED Yellow Transformer LED Red LED Green LED Yellow Resistor Neon a Transformer Transformer Neon a Transformer Type KM40 KM31 KM31LR KM31LG KM31LY KM32 KM32LR KM32LG KM32LY KM33 KM35 KM35LR KM35LG KM35LY KM35LW KM35LL KM36 KM1LR KM1LG KM1LY KM1 KMF1 KM38 KM38 KM11 KM38LR KM38LG KM38LY KM38LW KM38LL KM3 KM3LR KM3LG KM3LY KM7 KM7LR KM7LG KM7LY KM25 KM12 KM8 KM5 KM14 KM6 $ Price 78.00 86.00 116.00 116.00 116.00 86.00 116.00 116.00 116.00 86.00 86.00 116.00 116.00 116.00 116.00 116.00 86.00 143.00 143.00 143.00 116.00 116.00 86.00 86.00 86.00 116.00 116.00 116.00 116.00 116.00 116.00 143.00 143.00 143.00 116.00 143.00 143.00 143.00 86.00 86.00 116.00 116.00 86.00 116.00 Voltage Assembly Code 40 31 31LR 31LG 31LY 32 32LR 32LG 32LY 33 35 35LR 35LG 35LY 35LW 35LL 36 1LR 1LG 1LY 1 F1 38 38 11 38LR 38LG 38LY 38LW 38LL 3 3LR 3LG 3LY 7 7LR 7LG 7LY 25 12 8 5 14 6 Replacement Lamp Rating .9 VA Part Number b None 2550101020 6508805201 6508805203 6508805202 2550101037 6508805201 6508805203 6508805202 2550101037 2550101002 6508805210 6508805212 6508805211 6508805214 6508805213 2550101025 6508805201 6508805203 6508805202 2550101020 2550101036 2550101027 2550101027 2550101013 6508805210 6508805212 6508805211 6508805214 6508805213 2550101020 6508805201 6508805203 6508805202 2550101020 6508805201 6508805203 6508805202 2550101027 2550101013 2550101020 2550101020 2550101013 2550101020 $ Price 12.45 42.75 42.75 28.50 12.45 42.75 42.75 28.50 12.45 12.45 42.75 42.75 42.75 42.75 42.75 12.45 42.75 42.75 42.75 12.45 16.50 12.45 12.45 32.85 42.75 42.75 42.75 42.75 42.75 12.45 42.75 42.75 42.75 12.45 42.75 42.75 42.75 12.45 32.85 12.45 12.45 32.85 12.45
1.2 VA
2.4 VA .85 VA 3.0 VA 3.0 VA 0.2 VA 1.4 VA 1.4 VA 1.4 VA 1.4 VA 1.4 VA 2.5 VA
2.0 VA
19
PUSH BUTTONS AND OPERATOR INTERFACE
Not for use on KX operators. For use with all operators except KX and remote test pilot.
NOTE: Light modules are available in other voltages. For additional information, refer to Catalog 9001CT0001. For use in hazardous locationsSee page 19-83.
Reduces the depth of illuminated push buttons with contact blocks by over 33%. With LED light modules, use a cap that is the same color as the LED.
Table 19.229: Shallow Depth Light Modules For Types K and SK Control Units c
Type Full Voltage KM55 LED Red KM55LR 2428 Vac/Vdc LED Green KM55LG LED Yellow KM55LY Full Voltage KM58 LED Red KM58LR 110120 Vac/Vdc LED Green KM58LG LED Yellow KM58LY c For use with all operators except KX and remote test pilot. Voltage Description Light Module $ Price 86.00 116.00 86.00 116.00 Voltage Assembly Code 55 55LR 55LG 55LY 58 58LR 58LG 58LY Rating 1.2 VA 0.5 VA 3.0 VA 0.5 VA Replacement Lamp Part Number 2550101002 6508805204 6508805206 6508805205 2550101027 6508805204 6508805206 6508805205 $ Price 12.45 42.75 12.45 42.75
File CCN
E42259 NKCR
File Class
LR25490 3211 03
marked
19-82
CP10
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Hazardous locations do not always require the use of explosion-proof equipment like the Class 9001 Type BR control stations. Selecting the most appropriate device for the location can save you money. For more information on the types of hazardous locations, contact your local electrical inspector. Table 19.230: Square D Offering According to Class, Division, and Group
For Class Division Group(s) I 1 A 1. 1. 2. Use
Intrinsically Safe System 9001 BR station I 1 B, C, D Intrinsically Safe System control stations 1. 9001 K, SK, KX a with restrictions I 2 A 2. Intrinsically Safe System 1. 9001 BR station control stations I 2 B, C, D 2. 9001 K, SK, KX a with restrictions 3. Intrinsically Safe System 1. 9001 BR station II 1 E, F, G 2. Intrinsically Safe System 1. 9001 BR station control stations II 2 E, F 2. 9001 K, SK, KX a with restrictions 3. Intrinsically Safe System 1. 9001 BR station control stations II 2 G 2. 9001 K, SK, KX b with restrictions 3. Intrinsically Safe System 1. 9001 BR Station control stations III 1, 2 2. 9001 K, SK, KX b with restrictions 3. Intrinsically Safe System a Any Class 9001 Type K, SK or KX operator can be used in an area classified as Class I, Division 2 hazardous locations, if: 1. Only logic (KA40 series) or power (KA50 series) reed contact blocks are used. 2. All Type K and SK illuminated operators are UL approved for use in Class I Division 2 areas. c 3. Type KX illuminated operators do not use 4 lamp light modules, or 2 lamp light modules other than the transformer type. c 4. The operators are mounted in any NEMA 4 & 13 enclosures. b Any Class 9001 Type K, SK, or KX operator mounted in a Class 9001 Type KY, KYSS, KYAF, SKY enclosure may be used, except potentiometer operators. c Add Form Y243 to single lamp Push-To-Test pilot lights. Note: For a and b: UL Listed: File E10054(N), CCN NOIV.
KA42
42.80
KA43
42.80
KA44
86.00
KA45
86.00
The maximum number of logic and/or power reed contact blocks per operator is as indicated on individual selection tables for standard contact blocks, except:
On 3 position selector switches with cams C, D, E, F, G, L, or M, mount reed blocks on one side only (either side), maximum 2 in tandem. On 4 position selector switches, mount reed blocks on one side only (either side), maximum 2 in tandem. On joysticks or on Type KR8 or SKR8 push-pull operators, mount reed blocks on one side only (either side), maximum 2 in tandem.
KA53
101.00
KA54
143.00
KA55
143.00
AC NEMA C300 d Volts A 120 240 10.00 5.00 Make VA 1200 A 1.000 .500 DC NEMA Q150 e Continuous Carrying Amperes 115 .50 58 .50 58 3.0 Note: The power reed contact blocks can be used with standard industrial relays and starters through NEMA Size 4. Minimum voltage is 5 V and the minimum current is 1 mA. d Inductive Rating35% Power Factor. e Inductive and Resistive Ratings f Not for use in pendant stations. Volts A VA A VA Make Break Break VA 120 Continuous Carrying Amperes 3.0
CP1
Discount Schedule
19-83
19
143.00
30 mm Push Buttons
Example: A Type KR1B push button with 2 Type KA1 contact blocks would be Class 9001 Type KR1BH2.
The design of the Class 9001 Type KA contact blocks allows them to be mounted side by side and/or in tandem. This enables you to specify an operator and a particular arrangement of contact blocks (shipped completely assembled) with a single Type number. See page 19-78 for a description of contact blocks.
KA1 KA1
KA1
31 Preferred Cover Drilling
A30464-162
*1.22 Dia.
*1.22 Dia.
31
Dual Dimensions:
INCHES Millimeters
KA2 KA2
KA1 KA3
Hole Punch: Use Greenlee Tool #60242 to punch mounting hole and notch.
NOTE: For H Codes not shown in this table, contact your local Schneider Electric representative. Table 19.235: Dimensions When Using Contact Blocks
Panel Thickness .25 max. .06 min. 2 6 Panel Thickness 1/16 min.-1/4 max. 2.10 53
2 blocks mounted side by side only: Any 2, 3 or 4 position spring return selector switch (non-illuminated, illuminated or keyed). 2 blocks mounted in tandem on one side only: Any 2 operator interlocked push button. 2 blocks mounted in tandem (total of four blocks): Any selector push button, keyed push button, 2, 3, or 4 position maintained selector switch (non-illuminated, illuminated or keyed), push-pull operators (non-illuminated or illuminated), joy stick, dual push button. 3 blocks mounted in tandem (total of six blocks): Single momentary push buttons (non-illuminated or illuminated).
D D E F
B
1.60 41
Light KA Unit KA Unit KA Unit KA Unit Module
A
1.66 42 2.63 67 .97 25 0.56 14 3.66 93
KA Unit KA Unit KA Unit KA Unit Light Light
Module
Module
1.31
Standard Blocks
Reed Blocks
19
PUSH BUTTONS AND OPERATOR INTERFACE
1.13
D30052-287
Table 19.236: Basic Operators (Without Color Caps, Mushroom Buttons, Knobs, Selector Switch Cams, Contact Blocks, Light Modules, or Legend Plates)
Description For UL Types/NEMA $ Price 1, 3R, 4, 4, 4X, 13 12, 13 KR2 SKR2 38.55 KR3 SKR3 38.55
Non-Illuminated Push Button (Extended Guard) Non-Illuminated Push Button (No Guard) Non-Illuminated Push Button (Mushroom KR20 SKR20 38.55 Button/Screw-On) Non-Illuminated Dual Push Button (Momentary) KR6 78.00 Non-Illuminated Dual Push Button (Momentary KR67 121.50 Interlocked) Non-Illuminated Dual Push Button (Maintained KR7 121.50 Interlocked) Momentary PullMaintained Neutral KR8 ad SKR8 a 75.00 Momentary Push Maintained PullMaintained Push KR9 ad SKR9 a 120.00 Illuminated Push Button (Full GuardPlastic Top) K1L b SK1L b 42.75 Illuminated Push Button and Push-To-Test K2L bc SK2Lb c 28.65 (No Guard) Illuminated Push Button (Full GuardMetal Top) K3L b 42.75 Standard Pilot Light KP SKP 28.65 3 Position Maintained Selector Switch KS4 a SKS4 a 36.30 3 Position Spring Return Both Sides To Center KS5 a SKS5 a 64.80 Selector Switch 3 Position Spring Return Left To Center KS6 a SKS6 a 64.80 Selector Switch 3 Position Spring Return Right To Center KS7 a SKS7 a 64.80 Selector Switch a Operator can be converted to an illuminated operator by removing the liner (6512240601) and adding a light module. b Operator can be converted to a non-illuminated operator by adding liner (6512240601). c Operator includes jumper wires for push-to-test conversion. d These operators can be supplied with 1-3/8 in or 2-1/4 in dia. mushroom buttons. For 1-3/8 in.: add ( ) 20 to type number. The ( ) refers to the color chosensee page 19-88. For 2-1/4 in.: Add ( ) 21 to type number. The ( ) refers to the color chosensee page 19-88. Voids UL and NEMA 6 Rating.
19-84
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Silver White Black Silver White Black Silver White Black Legend with Legend with Legend with Legend with Legend with Legend with Legend with Legend with Legend with Black Letters Black Letters White Letters Black Letters Black Letters White Letters Black Letters Black Letters White Letters For Push Button or Pilot Light Blank KN200SP KN200WP KN200BP KN100SP KN100WP KN100BP Blank (red) KN200RP b KN200RP b KN200RP b KN100RP b KN100RP b KN100RP b Start KN201SP KN201WP KN201BP KN101SP KN101WP KN101BP Stop KN202RP b KN202RP b KN202RP b KN102RP b KN102RP b KN102RP b On KN203SP KN203WP KN203BP KN103SP KN103WP KN103BP Off KN204RP b KN204RP b KN204RP b KN104RP b KN104RP b KN104RP b Emerg. Stop KN205RP b KN205RP b KN205RP b KN105RP b KN105RP b KN105RP b Forward KN206SP KN206WP KN206BP KN106SP KN106WP KN106BP Reverse KN207SP KN207WP KN207BP KN107SP KN107WP KN107BP Close KN208SP KN208WP KN208BP KN108SP KN108WP KN108BP Open KN209SP KN209WP KN209BP KN109SP KN109WP KN109BP Down KN210SP KN210WP KN210BP KN110SP KN110WP KN110BP Up KN211SP KN211WP KN211BP KN111SP KN111WP KN111BP Fast KN212SP KN212WP KN212BP KN112SP KN112WP KN112BP Slow KN213SP KN213WP KN213BP KN113SP KN113WP KN113BP High KN214SP KN214WP KN214BP KN114SP KN114WP KN114BP Low KN215SP KN215WP KN215BP KN115SP KN115WP KN115BP Inch KN216SP KN216WP KN216BP KN116SP KN116WP KN116BP In KN217SP KN217WP KN217BP KN117SP KN117WP KN117BP Jog KN218SP KN218WP KN218BP KN118SP KN118WP KN118BP Jog For. KN219SP KN219WP KN219BP KN119SP KN119WP KN119BP Jog Rev. KN220SP KN220WP KN220BP KN120SP KN120WP KN120BP Lower KN221SP KN221WP KN221BP KN121SP KN121WP KN121BP Out KN222SP KN222WP KN222BP KN122SP KN122WP KN122BP Reset KN223SP KN223WP KN223BP KN123SP KN123WP KN123BP Run KN224SP KN224WP KN224BP KN124SP KN124WP KN124BP Start Jog KN225SP KN225WP KN225BP KN125SP KN125WP KN125BP Test KN226SP KN226WP KN226BP KN126SP KN126WP KN126BP Raise KN227SP KN227WP KN227BP KN127SP KN127WP KN127BP Decrease KN228SP KN228WP KN228BP KN128SP KN128WP KN128BP Increase KN229SP KN229WP KN229BP KN129SP KN129WP KN129BP Left KN230SP KN230WP KN230BP KN130SP KN130WP KN130BP Right KN231SP KN231WP KN231BP KN131SP KN131WP KN131BP KN232SP KN232WP KN232BP KN132SP KN132WP KN132BP Cycle Start Feed Start KN233SP KN233WP KN233BP KN133SP KN133WP KN133BP Cycle Stop KN234SP KN234WP KN234BP KN134SP KN134WP KN134BP Motor Run KN236SP KN236WP KN236BP KN136SP KN136WP KN136BP Motor Stop KN237SP KN237WP KN237BP KN137SP KN137WP KN137BP Power On KN238SP KN238WP KN238BP KN138SP KN138WP KN138BP Pull To Start N/A N/A N/A KN179SP KN179WP KN179BP Push To Stop For Selector Switch or Selector Push Button For.-Rev. KN239SP KN239WP KN239BP KN139SP KN139WP KN139BP Hand-Auto. KN240SP KN240WP KN240BP KN140SP KN140WP KN140BP High-Low KN241SP KN241WP KN241BP KN141SP KN141WP KN141BP Jog-Run KN242SP KN242WP KN242BP KN142SP KN142WP KN142BP Man.-Auto. KN243SP KN243WP KN243BP KN143SP KN143WP KN143BP Off-On KN244SP KN244WP KN244BP KN144SP KN144WP KN144BP On-Off KN245SP KN245WP KN245BP KN145SP KN145WP KN145BP Open-Close KN246SP KN246WP KN246BP KN146SP KN146WP KN146BP Raise-Lower KN247SP KN247WP KN247BP KN147SP KN147WP KN147BP Run-Jog KN248SP KN248WP KN248BP KN148SP KN148WP KN148BP Slow-Fast KN250SP KN250WP KN250BP KN150SP KN150WP KN150BP Start-Stop KN251SP KN251WP KN251BP KN151SP KN151WP KN151BP Up-Down KN253SP KN253WP KN253BP KN153SP KN153WP KN153BP Low-High KN254SP KN254WP KN254BP KN154SP KN154WP KN154BP Stop-Start KN255SP KN255WP KN255BP KN155SP KN155WP KN155BP Left-Right KN256SP KN256WP KN256BP KN156SP KN156WP KN156BP On-Auto KN276SP KN276WP KN276BP KN176SP KN176WP KN176BP Auto-Off-Hand KN258SP KN258WP KN258BP KN158SP KN158WP KN158BP For.-Off-Rev. KN259SP KN259WP KN259BP KN159SP KN159WP KN159BP Hand-Off-Auto. KN260SP KN260WP KN260BP KN160SP KN160WP KN160BP Man.-Off-Auto. KN262SP KN262WP KN262BP KN162SP KN162WP KN162BP Open-Off-Close KN263SP KN263WP KN263BP KN163SP KN163WP KN163BP Up-Off-Down KN264SP KN264WP KN264BP KN164SP KN164WP KN164BP Low-Off-High KN265SP KN265WP KN265BP KN165SP KN165WP KN165BP Jog-Stop-Run KN267SP KN267WP KN267BP KN167SP KN167WP KN167BP High-Low-Off KN270SP KN270WP KN270BP KN170SP KN170WP KN170BP High-Off-Low KN277SP KN277WP KN277BP KN177SP KN177WP KN177BP Auto-Man.-Off KN278SP KN278WP KN278BP KN178SP KN178WP KN178BP a Legend plate has red background with silver letters. b Legend plate has red background with black letters. For Pricing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 19-86 KN200 KN300 KN800 KN200 KN300 KN800 KN200R a KN300R a KN800R a KN201 KN301 KN801 KN202 a KN302 a KN802 a KN203 KN303 KN803 KN204 a KN304 a KN804 a KN205 a KN305 a KN805 a KN206 KN306 KN806 KN207 KN307 KN807 KN208 KN308 KN808 KN209 KN309 KN809 KN210 KN310 KN810 KN211 KN311 KN811 KN212 KN312 KN812 KN213 KN313 KN813 KN214 KN314 KN814 KN215 KN315 KN815 KN216 KN316 KN816 KN217 KN317 KN817 KN218 KN318 KN818 KN219 KN319 KN819 KN220 KN320 KN820 KN221 KN321 KN821 KN222 KN322 KN822 KN223 KN323 KN823 KN224 KN324 KN824 KN225 KN325 KN825 KN226 KN326 KN826 KN227 KN327 KN827 KN228 KN328 KN828 KN229 KN329 KN829 KN230 KN330 KN830 KN231 KN331 KN831 KN232 KN332 KN832 KN233 KN333 KN833 KN234 KN334 KN834 KN236 KN336 KN836 KN237 KN337 KN837 KN238 KN338 KN838 N/A KN379 N/A
KN779SP
KN779WP
KN779BP
KN739SP KN740SP KN741SP KN742SP KN743SP KN744SP KN745SP KN746SP KN747SP KN748SP KN750SP KN751SP KN753SP KN754SP KN755SP KN756SP KN776SP KN758SP KN759SP KN760SP KN762SP KN763SP KN764SP KN765SP KN767SP KN770SP KN777SP KN778SP
KN739WP KN740WP KN741WP KN742WP KN743WP KN744WP KN745WP KN746WP KN747WP KN748WP KN750WP KN751WP KN753WP KN754WP KN755WP KN756WP KN776WP KN758WP KN759WP KN760WP KN762WP KN763WP KN764WP KN765WP KN767WP KN770WP KN777WP KN778WP
KN739BP KN740BP KN741BP KN742BP KN743BP KN744BP KN745BP KN746BP KN747BP KN748BP KN750BP KN751BP KN753BP KN754BP KN755BP KN756BP KN776BP KN758BP KN759BP KN760BP KN762BP KN763BP KN764BP KN765BP KN767BP KN770BP KN777BP KN778BP
KN239 KN240 KN241 KN242 KN243 KN244 KN245 KN246 KN247 KN248 KN250 KN251 KN253 KN254 KN255 KN256 KN276 KN258 KN259 KN260 KN262 KN263 KN264 KN265 KN267 KN270 KN277 KN278
KN339 KN340 KN341 KN342 KN343 KN344 KN345 KN346 KN347 KN348 KN350 KN351 KN353 KN354 KN355 KN356 KN376 KN358 KN359 KN360 KN362 KN363 KN364 KN365 KN367 KN370 KN377 KN378
KN839 KN840 KN841 KN842 KN843 KN844 KN845 KN846 KN847 KN848 KN850 KN851 KN853 KN854 KN855 KN856 KN876 KN858 KN859 KN860 KN862 KN863 KN864 KN865 KN867 KN870 KN877 KN878
19-85
19
KN700SP KN700RP b KN701SP KN702RP b KN703SP KN704RP b KN705RP b KN706SP KN707SP KN708SP KN709SP KN710SP KN711SP KN712SP KN713SP KN714SP KN715SP KN716SP KN717SP KN718SP KN719SP KN720SP KN721SP KN722SP KN723SP KN724SP KN725SP KN726SP KN727SP KN728SP KN729SP KN730SP KN731SP KN732SP KN733SP KN734SP KN736SP KN737SP KN738SP
KN700WP KN700RP b KN701WP KN702RP b KN703WP KN704RP b KN705RP b KN706WP KN707WP KN708WP KN709WP KN710WP KN711WP KN712WP KN713WP KN714WP KN715WP KN716WP KN717WP KN718WP KN719WP KN720WP KN721WP KN722WP KN723WP KN724WP KN725WP KN726WP KN727WP KN728WP KN729WP KN730WP KN731WP KN732WP KN733WP KN734WP KN736WP KN737WP KN738WP
KN700BP KN700RP b KN701BP KN702RP b KN703BP KN704RP b KN705RP b KN706BP KN707BP KN708BP KN709BP KN710BP KN711BP KN712BP KN713BP KN714BP KN715BP KN716BP KN717BP KN718BP KN719BP KN720BP KN721BP KN722BP KN723BP KN724BP KN725BP KN726BP KN727BP KN728BP KN729BP KN730BP KN731BP KN732BP KN733BP KN734BP KN736BP KN737BP KN738BP
30 mm Push Buttons
19
Blank Legend Plates
Plate Color Yellow Green Blue Red Orange Burnt Orange Yellow Green Blue Red Orange Burnt Orange
1.7 in. Square 2.25 in. Square 2.5 in. Square $ Price KN200YP KN200GP KN200LP KN200CP KN200AP KN200HP KN299YP KN299GP KN299LP KN299CP KN299AP KN299HP KN100YP KN100GP KN100LP KN100CP KN100AP KN100HP KN199YP KN199GP KN199LP KN199CP KN199AP KN199HP KN700YP KN700GP KN700LP KN700CP KN700AP KN700HP KN799YP KN799GP KN799LP KN799CP KN799AP KN799HP
4.40
18.50
Table 19.240: Maximum Number of Lines and Characters for Type KN Legend Plates
Type KN100 KN200 KN300 KN400 KN500 KN600 KN700 KN800 KN900 Max. No. of 8 18 Characters 16 14 18 18 22 17 18 per field per pos. per Line Max. No. of 2 1 2 1 3 2 4 2 2 Lines per field per pos. Note: The maximum number of characters and lines is a practical maximum, based on a minimum size of characters to facilitate easy reading.
Table 19.241: Circular Legends for Emergency Stop Mushroom Heads (yellow background)
Diameter 60 mm 90 mm Text EMERGENCY STOP EMERGENCY STOP Catalog Number 9001KN9100 9001KN9330 9001KN8100 9001KN8330 $ Price
4.40
19-86
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
K4
42.80
Types K and SK selector switches and potentiometers (will not work with gloved-hand knob).
K7
42.80
K5 Types K and SK non-illuminated Holds button in push buttons with or depressed position without protective when padlocked. boots. K97
71.00
Types K and SK selector switches and Same as 9001K7 but potentiometers (will not with spring loaded work with gloved-hand lockout cover. knob).
K107
56.00
Type K5
42.80
Types K and SK illuminated push buttons (with or without guard) and key operated push buttons.
Cover type attachment that can be padlocked to keep unauthorized personnel from tampering with the operator.
K108
42.80
Type K97
Types K and SK non-illuminated push buttons, cover type attachment. KR, SKR
K6
42.80
Types K and SK illuminated push buttons Same as 9001K108 (with or without guard) but with spring loaded K109 and key operated push lockout cover. buttons.
57.00
Spring loaded cover Types K and SK cannot be push buttons, cover padlocked. Does not type attachment. hold button in depressed position.
K60
57.00
Types K and SK maintained push-pull operators using 1.375 in. dia. mushroom buttons (-20 series as shown on page 19-88).
Cover type attachment that holds mushroom button in K110 depressed position and can be padlocked.
54.00
Types K and SK push-pull operator and illuminated push buttons. KR8, KR9
K62
71.00
KR11U and KR12U Holds maintained button in depressed Interlocked position and can be Assembly padlocked.
K96
42.80
Note: These Type KU protective boots are recommended for very dirty environments or severe hose down, but they are not required for UL Type 4 rating on the Type K operators or UL Type 4 or 4X rating on the Type SK operators. The K1 wrench (see page 19-89) is required for installation of these boots. For Non-Illuminated Clear Color for Type $ Price Push Buttonsd Color Type $ Price Standard knob selector switch Black KU1 Gloved-hand cap for use on standard knob Red KU2 selector switch Blue KU3 28.70 Brown KU4 Standard pilot light and maintained contact Green KU5 push buttons Yellow KU6 Clear KU7 Push-to-test and illuminated push button Clear KU8 42.80 without guard (Provides Full Guard) Illuminated push button with guard d Use KU27 for maintained contact push buttons. KU17 KU18 42.80 42.80
KU37 KU47
42.80 57.00
Aluminum Mushroom Guard Yellow Plastic Extended Mushroom Aluminum Mushroom Guard for 1.375 in. Mushroom Button Guard for 1.375 in. and 1.625 in. for 2.25 in. Mushroom Button Operator (KR4, KR24) Mushroom Button Operators Operator Type $ Price Type Used On $ Price Type Used On $ Price KR4, K56b 57.00 K68 KR5 57.00 SKR4 K48 57.00 KR8, KR9, K56cMa SKR8, SKR9 68.00 K685 KR25 68.00 a The mushroom guard has finger holes for push-pull operators. b B=Black G=Green R=Red Y=Yellow c R=Red Y=Yellow
Description Type Gray K51e Black K52e Meets UL and NEMA 1, 2, 3, 4, 4X, 6, 12 and 13.
$ Price 14.30
CP1
Discount Schedule
19-87
19
Type KR9 & SKR9 Push-Pull Holds button in operators depressed position. Non-Illuminated Can be padlocked. and Illuminated
K162
59.00
KU27
42.80
KU1
KU17
KU37
KU27
30 mm Push Buttons
Table 19.249: Accessories
Description Color Black Blue Gray Green Orange Red Universal a White Yellow Black Blue Green Orange Red Red b Yellow Black Blue Green Orange Red Red b Yellow Black Blue Green Orange Red Yellow Black Blue Green Orange Red Yellow Amber Black g Blue Clear Green Orange g Red Red j White Yellow Black Green Red Universal h Amber Blue Clear Green Red White Yellow Red Red Green Black Red Green Black Red Green Black Red Green Black Type T8BK T8BE T8GY T8GN T8OE T8RD T8U T8WH T8YW K16B K16L K16G K16S K16R K16R05 K16Y K17B K17L K17G K17S K17R K17R05 K17Y K92B K92L K92G K92S K92R K92Y K93B K93L K93G K93S K93R K93Y A22 B23 L22 C22 G22 S23 R22 R2205 W22 Y22 B19 G19 R19 U19 A7 L7 C7 G7 R7 W7 Y7 R94 K92RM K92GM K92BM K93RM K93GM K93BM K94RM K94GM K94BM K95RM K95GM K95BM Package Qty. $ Price Each
Description
Color Amber Blue Clear Green Red White Yellow Amber Blue Clear Green Red White Yellow Amber Blue Clear Green Red White Yellow Amber Blue Clear Green Red White Yellow Amber Blue Clear Green Red White Yellow Amber Black g Blue Clear Green Orange g Red White Yellow Amber Black g Blue Clear Green Orange g Red White Yellow Black Blue Green Orange Red White Yellow Cam B C D E F G H J L M
Type A20 L20 C20 G20 R20 W20 Y20 A21 L21 C21 G21 R21 W21 Y21 A31 L31 C31 G31 R31 W31 Y31 A9 L9 C9 G9 R9 W9 Y9 A6 L6 C6 G6 R6 W6 Y6 A8 B11 L8 C8 G8 S11 R8 W8 Y8 A24 B25 L24 C24 G24 S25 R24 W24 Y24 T5BK T5BE T5GN T5OE T5RD T5WH T5YW Type K13B K13C K13D K13E K13F K13G K13H K13J K13L K13M
10
.72 1-3/8 in. Mushroom Knob for Illuminated Push Buttons K2L, SK2L i
9.90
Color inserts for KR1, KR2, KR3, SKR1, SKR2, SKR3, KR11, KR12, SKR11, SKR12, KRD, T, TRD
7 10
5.70 .70
9.90
2-1/4 in. Mushroom Knob for Illuminated Push Buttons K2L, SK2L i
9.90
Plastic Fresnel Pilot Light Lens for KP, KT, SKP, SKT
9.90
42.80
Domed Plastic Pilot Light Lens for KP, KT, SKP, SKT
9.90
9.90 1 15.80 9.90 1.40 10 8.60 Gloved-Hand Selector Switch Knob for K and SK Selector Switches 1 9.90 Standard Selector Switch Knob for K and SK Selector Switches
9.90
19
PUSH BUTTONS AND OPERATOR INTERFACE
a b c d e f g h i j
Color Inserts for Dual Function Operators KR6, KR7, KR67 Standard Color
9.90
Caps for Illuminated Push Buttons K1L, K2L, K3L, SK1L, SK2L Knob for KR9R94 Metal Knob for KR24 Metal Knob for KR25 Metal Knob for KR9 (40 mm) Metal Knob for KR9 (60 mm)
10
1.40
1 1 1 1 1
9.90 51.00 63.00 51.00 Selector Switch Cams 63.00 Color Inserts for KQ and TQ Selector Push Buttons
$ Price Each
6.30
Includes one each of the following color inserts: Black, Red, Green, Yellow, Orange, Blue, and White. EMERGENCY STOP is in raised letters and hot stamped white across the front of the mushroom button. The mushroom button cap listed here may be assembled to a 9001KR1U or SKR1U to form a 9001KR4 or SKR4. The mushroom button cap listed here may be assembled to a 9001KR1U or SKR1U to form a 9001KR5 or SKR5. The mushroom button cap listed here may be assembled to a 9001KR20 to form a 9001KR24 or SKR20 to form a 9001SKR24. The mushroom button cap listed here may be assembled to a 9001KR20 to form a 9001KR25 or a SKR20 to form a 9001SKR25. These color caps are opaque and are for use on non-illuminated operators only. Includes two of each of the following color inserts: Black, Red, and Green. May be used on KR8 and KR9 operators. Order mushroom button and K54 adapter (no charge) from page 19-84. Using the K54 adapter voids Type 6 rating. Red knob with Push Emergency Stop marked on top of knob.
19-88
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Type K69
$ Price 35.50
K95
Where Used For tightening ring nuts on 22 and 30 mm control units For protective cap kits Type K95 K1
K1
$ Price 42.75 71.40
CP1
Discount Schedule
19-89
19
NonIlluminated
Illuminated
Table 19.259: Push ButtonsDual with One Pilot Light and Contacts
1 2 3 Description Momentary Momentary Maintained a Top Button (#1) Start (Green) Start (Green) Start (Green) Middle Lens (#2) On (Red) On (Red) On (Red) Lower Button (#3) Stop (Red) Stop (Red) Stop (Red) Contacts 2 C/O 1 N/O, 1 N/C 1 C/O Voltage 110/120 110/120 110/120 Type KXRG117 KXRG137 KXRJ119 $ Price 314.00 270.00 329.00
Table 19.260: Push ButtonsDual with Two Pilot Lights and Contacts
Description 1 2 3 4 Momentary Momentary Momentary Momentary a b Top Button (#1) Start (Green) Start (Green) Start (Green) Start (Green) Left Lens (#2) On (Red) On (Red) On (Red) On (Red) Right Lens (#3) Off (Green) Off (Green) Off (Green) Off (Green) Lower Button (#4) Stop (Red) Stop (Red) Stop (Red) Stop (Red) Contacts 2 C/O 1 N/O, 1 N/C 2 C/O 1 N/O, 1 N/C Voltage 110/120 110/120 24 24 Type KXRL121 KXRL138 KXRL34GRGRH2 KXRL34GRGRH37 $ Price 485.00 441.00 451.00 494.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
19-90
CP1
Discount Schedule
1 2
Amber Red Green White Green Amber Red Green White Green Amber Amber Blue
CP1
Discount Schedule
19-91
19
19
PUSH BUTTONS AND OPERATOR INTERFACE
Momentary + Interlock
Maintained + Interlock
With Two Pilot Lights 24 Vac/dc Momentary 1 2 3 4 Momentary + Interlock 24 Vac/dc 110/120 Vac/dc 110/120 Vac/dc 24 Vac/dc 24 Vac/dc 110/120 Vac/dc 110/120 Vac/dc a Red Red Red Red Red Red Red Red White Red White Red White Red White Red White Green White Green White Green White Green Green Green Green Green Green Green Green Green KXRL35RWWG KXRL35GGRR KXRL38RWWG KXRL38GGRR KXRM35RWWG KXRM35RRGG KXRM38RWWG KXRM38RRGG 324.00 324.00 324.00 324.00 368.00 368.00 368.00 368.00
19-92
CP1
Discount Schedule
Selectors, 30 mm Square
www.schneider-electric.us
KA1
42.80
KA2
21.50
1 N/C
KA3
21.50
KA4
42.80
(Clear Cover)
KA5
21.50
(Red Cover)
KA6
21.50
(Green Cover)
CP1
Discount Schedule
19-93
19
(Red Cover)
30 mm Push Buttons
Type KX Accessories
Class 9001 / Refer to Catalog 9001CT0001
www.schneider-electric.us
1.23 31
1.23 31
1.23 31
0.56 14
0.56 14
0.48 12
0.26 7
0.43 11
B C (vertical)
$ Price
Table 19.271: Maximum Number of Lines and Characters For Type KXN Legend Inserts
Letter Number Height of in. mm Characters per Line 14 6 Lines per Legend Insert Characters per Line 3 16 4.75 Lines per Legend Insert Characters per Line 18 3 Lines per Legend Insert KXN199 7 4 9 5 14 8 KXN299 Horizontal 7 2 9 2 14 4 KXN299 Vertical 3 4 4 6 5 9 KXN399 7 1 9 2 14 3 KXN499 7 1 9 1 14 2 KXN599 3 1 4 2 6 3
A B C D E F KXRA, KXRB KXRN, KXRG, KXRP KXRH KXPA, KXRJ, KXPC KXRC, KXRG, KXRK KXTA, KXRD KXRH KXRL, KXRL, KXTB KXRE, KXPB KXRJ, KXRM KXRM Marking KXTE KXRF KXTD c KXRKa KXTC b KXTC a Blank KXN100 KXN200 KXN200 KXN300 KXN400 KXN500 Start KXN101 KXN201 KXN201V KXN301 KXN401 KXN501 Stop KXN102 KXN202 KXN202V KXN302 KXN402 KXN502 On KXN103 KXN203 KXN203V KXN303 KXN403 KXN503 Off KXN104 KXN204 KXN204V KXN304 KXN404 KXN504 Emerg. Stop KXN105 KXN205 KXN205V KXN305 KXN405 KXN505 Forward KXN106 KXN206 KXN206V KXN306 KXN406 KXN506 Reverse KXN107 KXN207 KXN207V KXN307 KXN407 KXN507 Close KXN108 KXN208 KXN208V KXN308 KXN408 KXN508 Open KXN109 KXN209 KXN209V KXN309 KXN409 KXN509 Down KXN110 KXN210 KXN210V KXN310 KXN410 KXN510 Up KXN111 KXN211 KXN211V KXN311 KXN411 KXN511 Jog KXN118 KXN218 KXN218V KXN318 KXN418 KXN518 Reset KXN123 KXN223 KXN223V KXN323 KXN423 KXN523 Run KXN124 KXN224 KXN224V KXN324 KXN424 KXN524 Cycle Start KXN132 KXN232 KXN232V KXN332 KXN432 KXN532 Motor Run KXN136 KXN236 KXN236V KXN336 KXN436 KXN536 Power On KXN138 KXN238 KXN238V KXN338 KXN438 KXN538 SpecialKXN199 KXN299 KXN299V KXN399 KXN499 KXN599 Marking a These legend inserts are for the pilot lights in the center of the operator. b These legend inserts are for the push button portion of the operator. c These legend inserts have vertical printing.
4.40
Table 19.272: Maximum Number of Lines and Characters for Type KXN699 and KXN799 Legend Plates
Letter Height 18.50 Position
B
in. 3 16
mm 4.75 3 4.75 3
18
3 16
C
(Pos. 1)
KXPB, KXTD
19-94
(Pos. 2)
19
PUSH BUTTONS AND OPERATOR INTERFACE
Marking Blank For.-Rev. Hand-Auto Man-Auto Off-On On-Off Open-Close Start-Stop Auto-Off-Hand Hand-Off-Auto Man-Off-Auto Special Marking
18
$ Price
KXSA, KXSB, KXSC, KXSD, KXSE, KXSF, KXSG, KXSH, KXSJ, KXSK, KXSL, KXSM, KXSN, KXSO, KXSP, KXSQ KXN600 KXN639 KXN640 KXN643 KXN644 KXN645 KXN646 KXN651 KXN658 KXN660 KXN662 KXN699
KXSR, KXSS, KXST, KXSV, KXSW, KXSX, KXSY, KXSZ KXN700 KXN739 KXN740 KXN743 KXN744 KXN745 KXN746 KXN751 KXN758 KXN760 KXN762 KXN799
All Type KX push buttons and pilot lights have a blank insert as standard. These blank inserts can be custom marked using a marking pen, a mechanical lettering set, press letters, or a tape lettering machine that marks a tape which can then be transferred to the blank insert. To have legend inserts installed into the operators, order the operator as normal and then indicate where to install the legend inserts using the numbered positions shown on the operator ordered.
9001KXRL1GRGRH2 with a 9001KXN 401 in position 1 9001KXN 503 in position 2 9001KXN 504 in position 3 9001KXN 402 in position 4
4.40
Example:
18.50
KXN200 (Pos. 1)
KXN400 (Pos. 1)
K X N 2 0 0
K X N 2 0 0
CP1
Discount Schedule
30 mm Push Buttons
www.schneider-electric.us
Type KX Accessories
Class 9001 / Refer to Catalog 9001CT0001
9.90
KXAK52 UL Types 4, 13/NEMA 4, 13 Square Closing Plate (Chrome Plated) Same size as KX bezel
14.30
Includes 2-KXN200
9.90
9.90
9.90
KXRA KXRB
6.60
17.10
9.90
KXALLRT Used to remove lamp and lens on all illuminated operators and pilot lights.
KXRG (Position 2) KXRH (Position 2) KXRJ (Position 2) KXRK (Position 2) KXRG (Position 1 & 3) KXRH (Position 1 & 3) KXRJ (Position 1 & 3) KXRK (Position 1 & 3) KXRL (Position 1 & 4) KXRM (Position 1 & 4)
9.90
9.90
Includes KXN400
9.90
Includes KXN500
9.90
a b c d e
9.90 Includes KXN100 Each KXAC28 includes a clear cover and 1 each of all colors. If the same color is required for position #1and #2 of the KXPB operator, order 2 of Type KXAC28. When specifying color codesthe first will be installed in #1 and the second in #2. The price for BOTH color codes is $6.60. Each KXAC48 includes a clear cover and 1 each of all colors. If the same color is required for position #1and #2 of the KXPC operator, order 2 of Type KXAC48. When specifying color codesthe first will be installed in #1, the second in #2, the third in #3 and the fourth in #4. The price for ALL FOUR color codes is $6.60. Two required per operator. When ordering an assembled operatorspecify two code numbers.The first code will be assembled into #1 and the second code will be assembled into #2.
CP1
Discount Schedule
19-95
19
Table 19.278: Start or Stop Function Polycarbonate; Light gray base, RAL7035; Dark gray lid, RAL7016
Description Type of Push Type of Contact N.O. 1 N.C. 1 Marking Catalog Number $ Price
XALD101
Marking on Legend Holder Flush black 1 momentary push button Flush red Marking on Legend Holder 1 mushroom head push button 40 mm, Red momentary
Start Stop
XALD101 XALD111
73.00 73.00
XALD164
84.00
Table 19.279: Emergency Stop or Emergency Off Function Polycarbonate; Light gray base, RAL7035; Yellow lid, RAL1012
Description 1 mushroom head push button 40 mm, red Turn-to-release 1 mushroom head push button 40 mm, red Key release (Key No. 455) 1 mushroom head push button 40 mm, red Push-pull a Emergency Off (IEC 60364-5-53) b Emergency Stop (EN / IEC 13850) Type Standard a Trigger action b Standard a Trigger action b Standard a Type of Contact N.O. N.C. 1 1 1 1 1 Catalog Number XALK174 XALK178 XALK184 XALK188 XALK194 $ Price 117.00 147.00 147.00 147.00 99.00
XALK174
Table 19.280: Start-Stop Function Polycarbonate; Light gray base, RAL7035; Dark gray lid, RAL7016
Description Type of Push 1 flush black 1 flush red 1 flush black 1 flush black Type of Contact N.O. 1 1 1 N.C. 1 Text Start Stop Forward Reverse Catalog Number XALD211 XALD221 $ Price 73.00 73.00
XALD211
Table 19.281: Three Function Polycarbonate; Light gray base, RAL7035; Dark gray lid, RAL7016
Description Type of Push Type of Contact N.O. 1 1 1 1 1 1 N.C. 1 1 1 Text Open Stop Close Forward Stop Reverse Up Stop Down Catalog Number XALD341 $ Price 143.00
19
PUSH BUTTONS AND OPERATOR INTERFACE XALD321
XALD311
143.00
XALD321
143.00
19-96
Discount Schedule
For normal environments, CSA approved and UL Listed (with stainless steel lid mounting screws) 1 2 Light gray base RAL7035 3 Dark gray lid RAL7016 4 5 Light gray base RAL7035 1 Yellow lid RAL1012
XALD02
Table 19.283: Electrical Block and Accessories (for mounting on metal plate at back of enclosure) a
Description Type Color White Green Red Yellow Blue White Green Red Yellow Blue White Green Red Yellow Blue Catalog Number ZENL1111 ZENL1121 ZALVB1 ZALVB3 ZALVB4 ZALVB5 ZALVB6 ZALVG1 ZALVG3 ZALVG4 ZALVG5 ZALVG6 ZALVM1 ZALVM3 ZALVM4 ZALVM5 ZALVM6 $ Price 16.60 16.40 Electrical blocks with screw clamp terminal connections N.O. contact Metal-plate-mounting contact blocks N.C. contact
ZENL1111
Light blocks with
24 Vac/Vdc
52.00
120 Vac
52.00
ZALV
230 Vac
52.00
For customer assembly using XB5 operators and standard screw-terminal contact blocks, see Push ButtonsZB5 22 mm starting on page 19-45. Either mounting method can be used: contact block ZENL mounting on metal plate, or contact block ZBE mounting on operator with mounting collar.
ZB5SZ3
ZB5AZ905
XAPA1100
XAPA1104
b
Uses standard XB5 products from pages 19-42 through 19-62. Do not use ZENL style contact blocks.
Discount Schedule
19-97
19
XAPG39400
Aluminum
2.93
XAPG29703
NEMA 4, 13 1.18 in. (30 mm) centerline spacing of holes for horizontal mount
1.93 NEMA 4, 13 1.58 in. (40 mm) centerline spacing of holes for vertical mount Zinc 2.93
1.93
74.5 74.5
XAPE302
XAPE303
Anodized Aluminum
19
PUSH BUTTONS AND OPERATOR INTERFACE
Insulating Fiberglass
32.80 60.00
19-98
Discount Schedule
86.00 BF101 86.00 BF102 99.00 129.00 83.00 BF107 86.00 86.00 83.00 86.00 BF201 107.00 99.00 129.00 116.00 107.00 107.00 107.00 BF208 107.00 86.00 BF210 107.00 BF211 78.00 129.00 BF215 129.00 BF216 122.00 171.00 171.00 171.00 BF303 171.00 171.00 BF305 171.00 162.00 314.00 BF308
On-Off Universal (w/o legend inserts) Start-Stop (Maintained Contact) On -Off (Maintained Contact) Universal (Maintained contact w/o legend inserts) Fast-Slow-Stop Forward-Reverse-Stop Opn-Close-Stop 3 Raise-Lower-Stop Up-Down-Stop Start-Jog-Stop Universal (w/o legend inserts) Start-Stop, Red Pilot Light: 120Vac/dc a b c
Pilot Light Lenses, NEMA 1 Flush Mount Replacement Covers for BW240 Replacement Covers for BW241 d Replacement Covers for BW242-BW260 d
CPI
Discount Schedule
19-99
19
See Table 19.294 on page 19-100. Uses standard 2.0 or 2.13 in. deep wall boxes, single gang for Types BF1 and BF2, two gang for Type BF3 Also rated for Class l, Division l and ll, Groups B, C, or D; Class ll, Division l and ll, Groups E, F, or G
Table 19.294: Replacement Interiors For Type B Standard Duty Push Button Stations
For Control Station Types BF101BF107 BF111BF114 BF121BF123 BF201BF214 BF215BF218 BF221BF224 BF225BF226 BF301BF307 BF308BF309 Contact Symbol 16 19 or 17 121 25 10 7 or 19 & 121 17 or 19 & 16 8 25 & 121 10 & 121 17 or 19 & 25 16 17 or 19 121 25 10 17 or 19 & 121 17 or 19 & 16 8 25 & 121 10 & 121 17 or 19 & 25 16 25 10 16 25 10 16 25 & & & & Contact Block Assembly q Type BOC107 BOC114 BOC123 BOC214 BOC218 BOC224 BOC226 BOC214 BOC107 BOC214 BOC123 BOC218 BOC123 BOC214 BOC114 BGC107 BGC114 BGC123 BGC214 BGC218 BGC224 BGC226 BGC307 BGC309 BGC313 BGC315 BOC107 BOC214 BOC218 BOC107 BOC214 BOC218 BOC360 BOC361 $ Price Terminal Block Wiring Receptacle Type 39.20 39.20 147.00 35.60 78.00 234.00 57.00 35.60 39.20 35.60 147.00 78.00 147.00 35.60 39.20 39.20 39.20 147.00 35.60 78.00 234.00 57.00 39.20 212.00 242.00 75.00 39.20 35.60 78.00 39.20 35.60 78.00 126.00 126.00 & & & & BFB107 BFB114 BFB123 BFB214 BFB214 BFB224 BFB226 BFB214 BFB107 BFB214 BFB123 BFB214 BFB123 BFB214 BFB114 BGB107 BGB114 BGB123 BGB214 BGB214 BGB224 BGB226 BGB307 BGB309 BGB309 BGB315 BFB107 BFB214 BFB214 BFB107 BFB214 BFB214 $ Price 42.80 42.80 42.80 42.80 42.80 64.00 64.00 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 42.80 64.00 64.00 57.00 86.00 86.00 86.00 42.80 42.80 42.80 42.80 42.80 42.80
Type BGC214
(Type BGC contact block assemblies include cover.) BF310BF313 BF314BF315 BG101BG107 BG111BG114 BG121BG123 BG201BG214 BG215BG218 BG221BG224 BG225BG226 BG301BG307 BG316BG326 BG308BG309 BG310BG313 BG314BG315 BR101BR107 BR202BR214 BR215BR219 BW101BW107 BW202BW214 BW215BW218 BW146BW159 BW240BW260
Type BGB214
19
PUSH BUTTONS AND OPERATOR INTERFACE BOC361
1 3
BW255BW258 10 BOC362 126.00 Note: Contact block assemblies for all Type BG stations include cover and contact block. Replacement contact block assemblies and terminal block wiring receptacles for push buttons have provision for 1 N.O. & 1 N.C. circuit on each button. Unneeded circuits need not be wired. a Order separate legend plates, if required, from listing on page 19-99. C Shaped Mounting Bracket for 9001BR Interior Catalog Number 3110112001 $ Price 8.70
120 30.5 3600 3.75 360 5 5 120 1.1 5 240 15 3600 1.5 360 5 5 240 0.55 5 480 7.5 3600 .75 360 5 5 600 0.2 5 600 6 3600 .6 360 5 5 b OSHA Regulation, Section 1910.70, Overhead and Gantry Cranes, limits the voltage of pendant push buttons to 150 Vac or 300 Vdc.
Contact Symbols
120 V 121 100 17 Com
10
16
19
25
109
145
146
NOTE: When ordering, add prefix 9001 to the catalog number 19-100
CP1
Discount Schedule 2009 Schneider Electric All Rights Reserved
30 mm Enclosures
www.schneider-electric.us
Sheet Steel No of Holes Type 1 2 3 4 6 a KYAF1 KYAF2 KYAF3 KYAF4 KYAF6 $ Price 143.00 158.00 185.00 228.00 287.00 KY1 KY2 a KY3 a KY4 a KY6
Die Cast Zinc Type $ Price 143.00 158.00 185.00 228.00 287.00
Stainless Steel (304) Type KYSS1 KYSS2 KYSS3 KYSS4 KYSS6 $ Price 257.00 270.00 372.00 485.00 714.00
Polymeric (Plastic) Type SKY1 SKY2 SKY3 SKY4 SKY6 $ Price 171.00 201.00 228.00 269.00 287.00
Only KN200 series legend plates will fit upright on these enclosures with their long axis vertical.
KYG1Y
No of Holes 1 2 3 4 b
Description 1 Hole flush plate, cover screws, insulating liners 2 Hole flush plate, cover screws, insulating liners 3 Hole flush plate, cover screws, insulating liners 4 Hole flush plate, cover screws, insulating liners K25 K26 K27 K28
Type
To be used with a standard 2 x 3 in. general purpose switch box. A 2.5 in. deep switch box should be used if two Type KA contact blocks are mounted side by side. If two Type KA contact blocks are mounted in tandem, a 3.5 in. deep box should be used.
K26
CP1
Discount Schedule
19-101
19
30 mm Control Stations
Table 19.299: Assembled Control Stations
No of Holes
Consists of Operator Style and Features Type $ Price Enclosure Operators Contact Blocks Legend Plates
UL Types 1, 3, 4 and 13/NEMA 1, 3, 4 and 13 Die Cast Zinc Enclosurea Selector Switch (3 Pos Maintained) Selector Switch (2 Pos Maintained) Push Button (Momentary) 1 Push Button (Momentary) Mushroom Button (Momentary) Push Button (with Lockout) Break Glass Operator Break Glass Operator (Red Enclosure) 2 Push Buttons (Lockout on Stop) 2 Push Buttons 2 Push Buttons 2 Push Buttons KYK111 KYK110 KYK11 KYK13 KYK14 KYK15 KYK116 KYK117 KYK224 KYK218 KYK26 KYK25 KYK21 KYK223 KYK23 KYK27 KYK22 KYK31 KYK326 KYK322 KYK33 KYK317 KYK32 KYK325 243. 243. 228. 228. 270. 270. 329. 329. 372. 329. 329. 329. 329. 527. 372. 329. 372. 441. 485. 783. 441. 471. 441. 485. KY1 KY1 KY1 KY1 KY1 KY1 KY1 KY1S1 KY2 KY2 KY2 KY2 KY2 KY2 KY2 KY2 KY2 KY3 KY3 KY3 KY3 KY3 KY3 KY3 KS43B KS11B KR1B KR1R KR4R KR3R, K4 K15 K15 KR1B, KR3R, K4 KR1B, KR3R KR1B, KR1B KR1B, KR1B KR1B, KR3R KR1B, KR3R KR1B, KR3R, K4 KR11GR KR1B, KR4R KR1B, KR1B, KR3R KR1B, KR1B, KR3R, K4 KR1B, KR1B, KR3R, K4 KR1B, KR1B, KR3R KP1R31, KR1B, KR3R KR1B, KR1B, KR3R KR1B, KR1B, KR3R, K4 KA1 KA1 KA1 KA1 KA1 KA1 KA1 KA1 KA1, KA1 KA1, KA1 KA1, KA1 KA1, KA1 KA1, KA1 KA51, KA51 KA1, KA1 KA1 KA1, KA1 KA1, KA1, KA1 KA1, KA1, KA1 KA51, KA51, KA51 KA1, KA1, KA1 KA2, KA3 KA1, KA1, KA1 KA1, KA1, KA1 Hand-Off-Auto Off-On Start Stop Stop Stop To StopBreak Glass To StopBreak Glass Jog-Stop On-Off Open-Close Up-Down Start-Stop Start-Stop Start-Stop Start-Stop Start-Stop Forward; Reverse; Stop Forward; Reverse; Stop Forward; Reverse; Stop Open; Close; Stop Start; Stop Up; Down; Stop Up ; Down; Stop
Type KYK31
2 Push Buttons 2 Push Buttons (with Sealed Contacts) d 2 Push Buttons (Lockout on Stop) 2 Push Buttons (Maintained/Interlocked) 1 Push Button, 1 Mushroom Button 3 Push Buttons 3 Push Buttons (Lockout on Stop) 3 Push Buttons (With Sealed Contacts & Lockout on Stop) d
3 Push Buttons Red 120v Pilot Light, 2 Push Buttons 3 Push Buttons 3 Push Buttons (Lockout on Stop)
UL Types 1, 3, 4 and 13/NEMA 1, 3, 4 and 13Stainless Steel (304) b Push Button (Momentary) 1 Push Button (Momentary) Selector Switch (2 Pos Maintained) Selector Switch (3 Pos Maintained) 2 Push Buttons KYSS101 KYSS103 KYSS110 KYSS111 KYSS201 KYSS203 KYSS210 KYSS205 342. 320. 356. 356. 422. 491. 441. 441. KYSS1 KYSS1 KYSS1 KYSS1 KYSS2 KYSS2 KYSS2 KYSS2 KR1B KR1B KS11B KS43B KR1B, KR3R KR1B, KR3R, K5 KR11U KR1B, KR1B KA1 KA3 KA1 KA1 KA1, KA3 KA1, KA3 KA1, KA1 KA1, KA1 Start Stop Off-On Hand-Off-Auto Start; Stop Start; Stop Start; Stop Up; Down
Type KYSS300
2 Push Buttons (Lockout on Stop) 2 Push Buttons (Maintained with Interlock) 2 Push Buttons
19
PUSH BUTTONS AND OPERATOR INTERFACE
UL Types 1, 3, 4. 4X and 13/NEMA 1, 3, 4, 4X and 13Stainless Steel (304) c Push Button (Momentary) 1 Push Button (Momentary) Selector Switch (2 Pos Maintained) Selector Switch (3 Pos Maintained) 2 Push Buttons 2 2 Push Buttons (Lockout on Stop) 2 Push Buttons (Maintained with Interlock) 2 Push Buttons KYSK101 KYSK103 KYSK110 KYSK111 KYSK201 KYSK203 KYSK210 KYSK205 342. 320. 356. 356. 422. 491. 441. 441. KYSS1 KYSS1 KYSS1 KYSS1 KYSS2 KYSS2 KYSS2 KYSS2 SKR1B SKR3R SKS11B SKS43B SKR1B, SKR3R SKR1B, SKR3R, K5 SKR11U SKR1B, SKR1B KA1 KA3 KA1 KA1 KA1, KA3 KA1, KA3 KA1, KA1 KA1, KA1 Start Stop Off-On Hand-Off-Auto Start; Stop Start; Stop Start; Stop Up; Down
UL Types 1, 3, 4. 4X and 13/NEMA 1, 3, 4, 4X and 13Polymeric (Plastic) c Selector Switch (3 Pos Maintained) Selector Switch (2 Pos Maintained) SKY111 SKY110 SKY122 SKY105 SKY201 SKY203 SKY223 SKY222 SKY205 SKY302 SKY303 SKY315A 270. 270. 372. 306. 350. 422. 570. 570. 372. 464. 464. 531. SKY1 SKY1 SKY1 SKY1 SKY2 SKY2 SKY2 SKY2 SKY2 SKY3 SKY3 SKY3 SKS43B SKS11B SKS11B SKR3R, K5 SKR1B, SKR3R SKR1B, SKR1R, K5 SKR1B, SKR3R SKR1B, SKR3R SKR1B, SKR1B SKR1B, SKR1B, SKR3R SKR1B, SKR1B, SKR3R SKP1R31, SKR1B, SKR3R KA1 KA1 KA51 KA3 KA1, KA3 KA1, KA3 KA51, KA51 KA51, KA51 KA1, KA1 KA1, KA1, KA3 KA1, KA1, KA3 KA1, KA3 Hand-Off-Auto Off-On Off-On Stop Start-Stop Start-Stop Start-Stop On-Off Up-Down Up-Down-Stop Open-Close-Stop Start-Stop
Type SKY201
Selector Switch (2 Pos Maintained with Sealed Contacts) d Push Button (with Lockout) 2 Push Buttons 2 Push Buttons (Lockout on Stop)
2 Push Buttons (With Sealed Contacts) d 2 Push Buttons (With Sealed Contacts) d 2 Push Buttons 3 Push Buttons 3 Push Buttons Red 120v Pilot Light, 2 Push Buttons
UL Types 1, 3, 4 and 13/NEMA 1, 3, 4 and 13 Die Cast Zinc Enclosures with Integral Guard Guarded Enclosure (grey) with 120V Red LED Pilot Light Guarded Enclosure (grey) with 120V Green LED Pilot Light 1 Guarded Enclosure (Yellow Cover) with Red Push-Pull Mushroom Guarded Enclosure (Yellow Cover) with Red Turn-To Release Mushroom a b c d KYG11 KYG12 KYG1Y1 KYG1Y2 250. 250. 275. 275. KYG1 KYG1 KYG1Y KYG1Y KP38LRR9 KP38LGG9 KR9R KR16 KA3 KA3 order separately order separately Emergency Stop Emergency Stop
Type KYG1Y2
Uses 9001K metal operators and metal legend plates. Uses 9001K metal operators and plastic legend plates. Uses 9001SK plastic operators and plastic legend plates. Control Station consists of components that are UL listed for use in Classi, Division 2, Groups A, B, C, or D.
19-102
CP1
Discount Schedule
Diameter (mm)
Sound Option
Enclosure Rating
Voltage
XVR 08ppp
12 Vac/Vdc 106
525875
Without buzzer
XVR 10ppp
12 Vac/Vdc 120 With buzzer IP 23 24 Vac/Vdc
525876
130
Without buzzer
IP 23 Resistant to vibration
12 Vdc 24 Vdc
Color Red Orange Green Blue Red Orange Green Blue Red Orange Green Blue Red Orange Green Blue Red Orange Green Blue Red Orange Green Blue Red Orange Green Blue Red Orange Green Blue Red Orange Red Orange
Catalog Number XVR 08J04 XVR 08J05 XVR 08J03 XVR 08J06 XVR 08B04 XVR 08B05 XVR 08B03 XVR 08B06 XVR 10J04 XVR 10J05 XVR 10J03 XVR 10J06 XVR 10B04 XVR 10B05 XVR 10B03 XVR 10B06 XVR 12J04 XVR 12J05 XVR 12J03 XVR 12J06 XVR 12B04 XVR 12B05 XVR 12B03 XVR 12B06 XVR 12J04S XVR 12J05S XVR 12J03S XVR 12J06S XVR 12B04S XVR 12B05S XVR 12B03S XVR 12B06S XVR 13J04 XVR 13J05 XVR 13B04 XVR 13B05
$ Price
120.
138.
132.
144.
180.
XVR 12ppp
Rubber base to increase the IP degree of protection Mount tube and base L-shape mounting bracket
24.
180. 18.
XVR 13ppp
XV
Discount Schedule
19-103
19
525877
Description
PF538692
Voltage Vac/Vdc
Catalog Number
$ Price
with support tube mounting XVC 4B1 XVC 4B2 XVC 4B3 XVC 4B4 XVC 4B5 XVC 4B15S XVC 4B25S XVC 4B35S XVC 4B45S XVC 4B55S XVC 4B1K XVC 4B2K XVC 4B3K XVC 4B4K XVC 4B5K 105. 132. 153. 189. 235. 160. 181. 206. 252. 294. 78. 103. 126. 170. 221.
Without buzzer
24
24
Without buzzer
24
XVC 4B5
XVC 4B35S
Die-cast metal mounting base (for use with XVC4B and 90 XVC4B 5S with support tube) Plastic mounting base (for use with XVC4, XVC4B and XVC4B 5S customer must 84 discard the support tube)
24.5
XVC Z01
43.
XVC Z11
Without buzzer
24
24
XVC 6B1 8 XVC 6B2 XVC 6B3 XVC 6B4 XVC 6B5 XVC 6B15S XVC 6B25S XVC 6B35S XVC 6B45S XVC 6B55S XVC 6B1K XVC 6B2K XVC 6B3K XVC 6B4K XVC 6B5K XVC 6B15SK XVC 6B25SK XVC 6B35SK XVC 6B45SK XVC 6B55SK
113. 141. 168. 202. 284. 168. 195. 210. 252. 315. 88. 109. 143. 189. 252. 137. 168. 189. 231. 284.
PF538684
PF538683
19
PUSH BUTTONS AND OPERATOR INTERFACE
Without buzzer
24
24
XVC 6B5K
Die-cast metal mounting base for XVC6B and XVC6B5S with 100 30 XVC Z02 18. support tube. XVC 6B55SK Stamped metal mounting base for 84 21.6 XVC Z12 30. XVC6B K and XVC6B5SK a Signaling colors: R = Red, G = Green, O = Orange, B = Blue, C = Clear. The colors are listed in the mounting order of the illuminated units from top to bottom. b Includes pre-wiring for steady or flashing lights.
19-104
XV
Discount Schedule
24
24
a b
Signaling colors: R = Red, G = Green, O = Orange, B = Blue, C = Clear. The colors are listed in the mounting order of the illuminated units from top to bottom. Included pre-wiring for steady or flashing lights.
PF538686
XVC Z13
PUSH BUTTONS AND OPERATOR INTERFACE
2009 Schneider Electric All Rights Reserved
XV
Discount Schedule
19-105
19
76.00
XVBL3
Color Green Red Amber Blue Clear Yellow Green Red Amber Blue Clear Yellow
Catalog Number XVBL4B3 XVBL4B4 XVBL4B5 XVBL4B6 XVBL4B7 XVBL4B8 XVBL4M3 XVBL4M4 XVBL4M5 XVBL4M6 XVBL4M7 XVBL4M8
$ Price
129.00
XVBL4B
Table 19.310: XVB Beacons with 10 Joule Strobe (2.75 in./70 mm diameter) a
Color Catalog Number b $ Price Green XVBL8B3 Red XVBL8B4 Amber XVBL8B5 Strobe 24 Vac/Vdc Blue XVBL8B6 Clear XVBL8B7 Complete unit, includes: Yellow XVBL8B8 1 lens unit 244.00 1 base unit (direct or tube Green XVBL8G3 mounting) Red XVBL8G4 Amber XVBL8G5 Strobe 120 Vac Blue XVBL8G6 Clear XVBL8G7 Yellow XVBL8G8 a Important: Discharge tube elements are not suitable for continuous-operation signaling due to temperature rise caused by the discharge tube. b For 5 Joule units, specify XVBL6, instead of XVBL8 ($190.00). Description Light Source and Voltage
19
XVBL6B 5 Joule PUSH BUTTONS AND OPERATOR INTERFACE XVBL8B 10 Joule
19-106
XV
Discount Schedule
XVBC8 XVBC081
40.40
Description
Light Source and Voltage Bulb (10 W max) not included 24 Vac 2448 Vdc
Color Green Red Orange Blue Clear Yellow Green Red Orange Blue Clear Yellow
Catalog Number XVBC4B3 XVBC4B4 XVBC4B5 XVBC4B6 XVBC4B7 XVBC4B8 XVBC4M3 XVBC4M4 XVBC4M5 XVBC4M6 XVBC4M7 XVBC4M8
$ Price
XVBC9
94.00
XVBC1
XVBC07 XVBC23
XVBZ0
209.00
XVBC12
a For 5 Joule units, specify XVBC6, instead of XVBC8 ($155.00). Note: There are no replacement lenses units for the XVBC strobe.
XV
Discount Schedule
19-107
19
XVBZ0
5.40
72.00
XVBC020
93.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
XVBC12
5.20 2.10
5 4
4 2
5 3 1 C 1
4 2
5 3 1
3 2 1
XVBL
XVBC
19-108
XV
Discount Schedule
24 Vac/Vdc Integral LED Illuminated units (separate bulb not requires) 120 Vac
XVEC21
Color of lens Green Red Orange Blue Clear Green Red Orange Blue Clear Green Red Orange Blue Clear
Catalog Number XVEC33 XVEC34 XVEC35 XVEC36 XVEC37 XVEC2B3 XVEC2B4 XVEC2B5 XVEC2B6 XVEC2B7 XVEC2G3 XVEC2G4 XVEC2G5 XVEC2G6 XVEC2G7
$ Price
16.00
40.00
XVEC9
Illuminated units Integral LED
24 Vac/Vdc
120 Vac
Green Red Orange Blue Clear Green Red Orange Blue Clear
XVEC5B3 XVEC5B4 XVEC5B5 XVEC5B6 XVEC5B7 XVEC5G3 XVEC5G4 XVEC5G5 XVEC5G6 XVEC5G7
60.00
70.00
8
Table 19.321: XVE Audible Sounder Units
Description Audible Sounder Units 85dB Supply Voltage Catalog Number XVEC9B XVEC9G XVEC9M Price 60.00
Mounting bases comprising: 25 mm aluminium support tube + black plastic mounting support Description Clear incandescent bulbs with BA 15d base fitting for lens units type XVE C3p
15.7 (400)
4.10
XV
Discount Schedule
19-109
19
XVPC09
Description Base unit and cover Base unit and cover Base unit and cover (with ring-tongue compatible terminal)
$ Price 32.00
XVPC3 XVC21
Black
(See Table 19.327 on page 19-111 and Table 19.328 on page 19-111 for LEDs and incandescent bulbs) Off-white
29.00
XVPC3
Strobe
Black Strobe 120 Vac 0.6 Joule Lens unit with integral strobe Strobe 24 Vdc 0.3 Joule Off-white Strobe 120 Vac 0.6 Joule
124.00
19
PUSH BUTTONS AND OPERATOR INTERFACE
104.00
Off-white
19-110
XV
Discount Schedule
24 Vac/Vdc
72.00
120 Vac
DL1BEJ
DL1BDB1
Flashing LEDs
24 Vac/Vdc
93.00
120 Vac
5.40
XVPC03T
Silver
XVPC02
Wall mounting bracket (metal) Bulb mounting and removal tool
Wiring Diagram
Cable Connections, Supply line maximum: 1.5 mm2 (16 AWG)
XVPC12 PUSH BUTTONS AND OPERATOR INTERFACE
+/4
wire 5 wire 4 wire 3 wire 2 wire 1 wire 6 green-yellow
+/5
+/3 +/2
12 0.47
+/1 /C
XVPC21
XV
Discount Schedule
19-111
19
XVS14BMW
Electronic alarms 90 dB, 16 tones Panel Mount DIN72 PNP White , 12/24 Vac/Vdc
XVS72BM
= 25 84 140 52 = 50
20
97 120 XVS 72BMpp 69,3 63,3 10,9 60,7 72
U 67,5
51
24
19-112
72
114
19
PUSH BUTTONS AND OPERATOR INTERFACE
XV
Discount Schedule
Pendant Stations
www.schneider-electric.us
BW70 / BW80
Table 19.332: BW90 and BW100 Pendant Stations with cord connector and strain relief
Up-Down Forward-Reverse On-Off a Start-Stop Start-Stop a Single Speed On-Off a Up-Down without Inserts without Inserts without Inserts a without Inserts Two Speed Up-Down Yes BW102Y BW100B BW102R 202.00 150 BOC367 150 Yes Yes Yes No Yes No Yes Yes No Yes Yes BW92Y BW93Y BW94Y BW95Y BW96Y BW97Y BW98Y BW90YU BW91YU BW94YU BW100YU BW92B BW93B BW94B BW95B BW96B BW97B BW98B BW90BU BW91BU BW94BU BW100BU BW92R 136.00 BW93R BW94R BW95R BW96R BW97R BW90RU 130.00 BW91RU BW94RU BW100RU 25 172.00 147 195.00 150 BOC359 BOC358 BOC367 25 147 150 158.00 90.00 146 180.00 10 136.00 145 180.00 10 136.00 146 147.00 100 147 BOC368 BOC358 BOC359 BOC358 BOC359 BOC366 25 146 147 90.00 25 147 25 146 BOC368 146
BW90 / BW100
Maintained Contact
Table 19.333:
Description
Hanger Brackets
Form Y236 B350 Price 10.50
Y236 B350
B251 B252
CP1
Discount Schedule
19-113
19
B258
Pendant Stations
XACA201a
150.00
XACA207a
222.00
XACA201
XACA205a
187.00
XACD21A0101b
167.00
XACD21A1231b
451.00
XACD21A0105b
202.00
XACD21A1241b
480.00
These units are available with factory installed E-stops. Add a 3 to the end of the catalog number for standard E-stop or add a 4 for a trigger action E-stop. Consult your local Schneider Electric sales office for price adder. These units are available with a factory installed E-stop. Use XACD22 for a standard E-stop or XACD24 for a trigger action E-stop.
XACA06
19
PUSH BUTTONS AND OPERATOR INTERFACE XACA03 with operators
19-114
Discount Schedule
Pendant Stations
www.schneider-electric.us
49.00
ZB2BE10
XENG37
XENG1191
XACS10
Wiring Diagrams
13 21 14 22 13 21 14 22 13 14 13 14 33 34 33 34 13 14 11 12
12
22
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
8.20
36.80
32
11
21
31
Mushroom Head
79.00
112.00
9.60
Wobble Stick
Discount Schedule
19-115
19
Pendant Stations
XACA971
XACB961
Replacement bulbs (Type BA9s) Incandescent Neon (use with direct supply light module)
Voltage 6 Vac/Vdc 12 Vac/Vdc 24 Vac/Vdc 48 Vac/Vdc 130 Vac/Vdc 120 Vac/Vdc 220 Vac/Vdc 380 Vac/Vdc
Catalog Number DL1CB006 DL1CE012 DL1CE024 DL1CE048 DL1CE130 NE51HRT120V NE51HRT220V NE51HRT380V
$ Price
11.00
15.20
DL1CJUS (LED)
LED, BA9s base for Direct Supply blocks
25.00
XACA983
19
PUSH BUTTONS AND OPERATOR INTERFACE
4.20
$ Price 4.20
17.80
19-116
Discount Schedule
Pendant Stations
www.schneider-electric.us
This line of pendant stations consists of polymeric enclosures (2 through 10 units), push button units (1 through 5 speed) and laminated legend plates. All enclosures have an extra single unit space near the top which permits the installation of a toggle switch, a Type SK operator or pilot light, or a warning label. All enclosures come with a stainless steel hanger bracket and internal strain relief post. Enclosures are yellow and have a threaded opening in the top. The complete line is UL Listed and CSA Certified with NEMA Type environmental ratings 1, 3, 4, 4X and 13. NOTE: To order, add prefix 9001 to the catalog number. Table 19.348: Enclosure Catalog Numbers
Number of Buttons 2 4 6 8 10 a b c Conduit Entrance Size
3/ "-14 NPT 3/4"-14 NPT 4 1"-111/2 NPT 11/4"-111/2 NPT 11/4"-111/2 NPT
$ Price
$ Price
SKYP2 189.00 SKYP20 SKYP4 239.00 SKYP40 SKYP6 287.00 SKYP60 c SKYP8 356.00 SKYP80 SKYP10 428.00 SKYP100 Class 9001 SK push-to-test pilot lights and remote test pilot lights will not fit in these enclosures. Assembled pendant stations consist of an enclosure, operators and legend plates. All custom orders must include the pendant key sheet available as shown on page 19-118. The price of an assembled pendant SKYP station includes the enclosure and components plus a 10% assembly charge. (Example: 9001 SKYP2 ($189), + SKRU1 ($129), + SKN201 ($8.60) = $326.60 + 10% = $360. Hanger bracket (Part no. 65091-061-01) Threaded conduit hole Space for toggle switch, a type SK operator or pilot light. Use appropriate legend plates.
Type SKYP enclosure Type SKRU1 through SKRU11 operators. Any Type SK pilot light or operator can be mounted in this enclosure. The enclosure depth will accommodate 1 Type KA1 thru KA6 (total of 2) contact blocks. Type SKN2 legend plate
8.60
4.40
18.50
Can be supplied by Square D as Class 9001 Type SKSTS1- includes boot for NEMA Type 4X. See 9001SK on pages 19-73 thru 19-80. Includes legend plate, gasket and ground plate to be used with toggle switch. Tri-laminated legend plate having a yellow or red background on a black core. 19 characters each side max.
Types SKRU 1, 10 and 11 use Type KA contact blocks. Types SKRU 2 thru 5 are factory enclosed contact blocks.
2 1 Terminals C 1 2
Terminals C 1 2
Terminals C 1 2 3
3 2 1
SK52
Terminals C 1 2 3
14.30
Figure 19.2:
2868-D30 87
2868-D29
88
Terminals C 1 2 3 4
4 3 2 1
Terminals C 1 2 3 4
Terminals C 1 2 3 4 5
7
Terminals C 1 2 3 4 5
10
2868-D31
2868-D32
89
90
CP1
Discount Schedule
19-117
19
Figure 19.1:
Cat. No.
$ Price
Pendant Stations
Control Products
KEY SHEET FOR ORDERING CLASS 9001 TYPE SKYP ASSEMBLED PENDANT CONTROL STATIONS
CUSTOMER ORDER NO. LIST PRICE EACH, CP1 QUANTITY Class
CUSTOMER DATE
9001
Type
SKYP -________
Space for toggle switch , a Type SK operator or pilot light, or a warning label. Use SKN-5 or SKN-1 legend plates.
1. 2. 3.
Operator or Closing Plate. Example - SKRU1 Legend Plate Type Number Example - SKN201
TYPE NUMBER KEY When operator and legend plate use 2 adjacent holes - specify same in both locations. Example:
B A C 1 SKRU1 2 SKN201 3 1 SKRU1 2 SKN201 3
1 2 3
Legend Plate Marking Used Only if Special Marking is Required Example: Line 2 - SKN299 Line 3 - A.) Hoist B.) FWD C.) REV
1 2 3 A) B) C)
1 2
Size
Hanger bracket Threaded conduit hole Space for toggle switch , a Type SK operator or pilot light or a warning label. Use SKN5 or SKN1 legend plates. Type SKYP enclosure Type SKRU1 through SKRU11 operators. Type SKN2 legend plate
LEGEND PLATES NEMA / UL 4X, 13
Where Used Marking Blank-Blank Hoist: Up-Down Trolley: East-West Trolley: Fwd.-Rev. Trolley: North-South Bridge: Fwd.-Rev. Bridge: East-West Bridge: North-South Start-Stop Reset-Stop Specify Marking Blank Off-On On-Off Specify Marking Blank On Off Emerg. Stop Run Power On Off-On Specify Marking Specify Marking (Red Background) Type SKN200 SKN201 SKN202 SKN203 SKN204 SKN205 SKN206 SKN207 SKN208 SKN209 SKN299 SKN500 SKN544 SKN545 SKN599 SKN100 SKN103 SKN104 SKN105 SKN124 SKN138 SKN144 SKN199 SKN199R
A) B) C)
1 2 3 A) B) C)
1 2 3 A) B) C)
1 2 3 A) B) C)
19
PUSH BUTTONS AND OPERATOR INTERFACE
1 2 3 A) B) C)
SKRU1 SKRU10 SKRU11 SKRU2 SKRU3 SKRU4 SKRU5 With Type SK Operator or Pilot Light in Top Space of Enclosure With Toggle Switch in Top Space of Enclosure For SKRU1 through SKRU11
Type SKRU1 through SKRU11 operators or Type SK operators and Type SKN-2 legend plate.
1 2 3 A) B) C)
1 2 3 A) B) C)
1 2 3 A) B) C)
CLOSING PLATE
Type SK52
Can be supplied by Square D as 9001SKSTS1 Includes legend plate, gasket and ground plate to be used with toggle switch. Tri-laminated legend plate having a yellow or red background on a black core. 19 characters each sides. Class 9001 Type SK Push-To-Test Pilot lights and Remote Test Pilot lights will not fit in these enclosures.
1 2 3 A) B) C)
19-118
CP1
Discount Schedule
Foot Switches
www.schneider-electric.us
Heavy Duty Industrial Foot SwitchesOiltight, Watertight, Dusttight and Driptight Enclosure, NEMA 2, 4 and 13
DANGER
HAZARDOUS APPLICATIONS Do not use foot switches on machines without point-of-operation protection. Failure to follow these instructions will result in death, serious injury, or equipment damage.
Type AW Foot Switch with Top Pedal Shield and Side Shields
Operating Temperature: 30 to +60 C (22 to +140 F) NOTE: To order, add prefix 9002 to the catalog number. Table 19.352: Foot Switch Catalog Numbers
Fully Shielded with Oversized Pedal Shield, Side Shields and Safety Door With Oversized Pedal Shield and Side Shields With Pedal Shield and Side Shields UNSHIELDED (See Warning noted)
Description
Features
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Single Poleb Spring Return AW117 750.00 AW132 750.00 AW2 363.00 AW1 396.00 Double Throw With Mechanical Latch AW7 527.00 Two Pole b Spring Return AW124a 903.00 AW133 903.00 AW14 527.00 AW13 575.00 Double Throw With Mechanical Latch AW15 692.00 Two Stage b Spring Return AW119 930.00 AW134 930.00 AW6 543.00 AW5 590.00 (One Pole Each With Mechanical Latch in 1st Stage AW9 705.00 Stage) Table 1 With Mechanical Latch in 2nd Stage AW10 705.00 Four Stage b AW21 995.00 (One Pole Each Spring Return AW123 1295.00 AW22 912.00 Stage) Table 2 Single Pole Maintained ContactPush On/Push Off AW12 527.00 AW11 575.00 Single Throw Replacement AC5 363.00 AC7 363.00 AC8c 140.00 AC1 153.00 Cover Assembly a 2 N.O. and 2 N.C. isolated, direct acting contacts. b A single pole snap switch that contains two double break contact elements (1 N.O. and 1 N.C.) must be used on circuits of same polarity. A double pole snap switch contains two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set that contains two double break contact elements (1 N.O. and 1 N.C.) must be used on circuits of same polarity. c For replacement cover drilled to accept latch. For Series C foot switches order AC9. Price is $182.00 No replacement cover available for Series A or B devices drilled to accept latch. AC8 is spring return only. d WARNING: These foot switches must not be used to operate machines or equipment where the possibility of operator injury exists. Typical uses include Emergency Stop functions, Dead Man controls, signal functions (lights, bells, etc.).
File CCN
E42259 NKCR
File Class
For replacement parts for Class 9002 Type AW: See instruction bulletin 65013-010-31. For contact symbol tables, see page 19-120
CP1
Discount Schedule
19-119
19
Foot Switches
Approximate Dimensions
(5) .34 Dia. Mtg. Holes 9
3.50 89 4.50
114
6.40
163
3.50 89 5.63
143
2.94
75
1.25
32
11.13
283
.38
10
.94
24
2.90
74
.94
24
5.02
128
8.56
217 3/4 14 Pipe Tap
5.38
137
3.50
89
Types AW117, AW119, AW123, AW124 Types AW132, AW133 and AW134 (without safety door)
1.44
37
AC Amperes Resistive Inductive 75% Power 35% Power Factor Factor Make AW1 through AW10, AW117, AW119, AW132 Break Make, Break and Continuous 125 250 600 125 250 600 125 250 120 240 600
DC Amperes Inductive and Resistive Make and Break Single Throw 2.0 0.5 0.1 1.0 0.3 0.1 2.2 1.1 1.1 0.55 0.2 Double Throw 0.5 0.2 0.02 0.2 0.1 Continuous 15 15 15 10 10 10 10 10 10
4.84
123
.94
24
Type
Volts
Volts
6.87
174
9.00
229
3/4-14 NPT
Types AW2, AW6, AW12, AW14 and AW22 PUSH BUTTONS AND OPERATOR INTERFACE
120 40 15 15 240 20 10 10 480 10 6 6 600 8 5 5 120 30 3 3 AW13, AW14, AW15, 240 15 1.5 1.5 AW133 480 7.5 0.75 0.75 600 6 0.6 0.6 115 36 6 AW11, AW12 230 18 3 120 15.0 1.5 10 AW21, AW22, 240 7.5 0.75 10 AW123 480 3.75 0.375 10 600 3.0 0.3 10 120 60 6 10 240 30 3 10 AW124 10 480 15 1.5 10 600 12 1.2 Note: Double throw switches are rated 250 Vdc maximum.
19
19-120
CP1
Discount Schedule
Off-On/On-Off switches Stepping switches Changeover switches Measurement switches Functions Reversing switches Reversing star-delta switches Pole change switches Conventional rated thermal current (Ith) Rated insulation voltage (Ui)
1 to 6-pole 2 to 12-position, 1 to 4-pole 1 to 5-pole Voltmeter and ammeter 2 and 3-pole Star-delta 2 and 3-speed 20 A 690 V AC-3 - 3-phase 230 V - 2.2 kW - 8.3 A AC - 15 230 V - 4 A IP 40 IP 65 (with seal) Complete switches and custom Adaptable sub-assemblies 22 control and signalling units Multi-fixing Single 22 hole Screw fixing, 4 holes on 36 mm centers 45 x 45 60 x 60 (adaptable sub-assemblies) Black and red standard and long handles Key operator Metallic head Metallic legend with black marking or black legend with white marking UL-CSA EN/IEC 60947-3 EN/IEC 60947-5-1 Type K2 Class 9003, K2
1 to 6-pole 1 to 4-pole 2 and 3-pole Star-delta 2-speed 32 A 690 V AC-3 - 3-phase 230 V - 5.5 kW AC - 15 230 V - 14 A IP 40 Complete switches By 4 holes on 48 mm centers Screw fixing, 4 holes on 48 mm centers 64 x 64 By 4 holes on 68 mm centers Screw fixing, 4 holes on 68 mm centers 88 x 88 50 A 690 V AC-3 - 3-phase 230 V - 7.5 kW AC - 15 230 V - 6 A 63 A 690 V AC-3 - 3-phase 230 V - kW 115 A 690 V AC-3 - 3-phase 230 V - 5 kW 150 A 690 V AC-3 - 3-phase 230 V - 22 kW
Front plate degree of protection Product composition Compatibility Mounting Front mounting Rear mounting Front plate dimensions (mm)
Operating heads
cULus EN/IEC 60947-3 Type K30K150 K30 K50 K63 K115 K150
NOTE: When indicating a contact closure, place X within the square as shown in the contact sequence example. Table 19.357: Switching Angle Chart
90 60 45 30
1
8
1 2 3 6 4 5
12 11 10 9 8
6
4 2
2
7
X X X X X X X X X X X X X
5
3
3 4
19-121
19
2.
xXSwitching AnglexX 90 60 45 30 Contact size Switching angle Operator/Handle type Separate legend
3. 4. 5. 6.
See Ordering xInstructions at LeftxX 2-3 4-5 6-7 8-12 Type Type
Type Type
T E R M I N A L S
1-2 3-4 5-6 7-8 9-10 11-12 13-14 15-16 17-18 19-20 21-22 23-24 25-26 27-28 29-30 31-32 33-34 35-36 37-38 39-40
19
PUSH BUTTONS AND OPERATOR INTERFACE
19-122
22 mm Push Buttons
www.schneider-electric.us
Maintained biometric switches, Type XB5S1B, with two fixed states Momentary biometric switches, Type XB5S2B, with pulse output The administrator who manages the registration and deletion of fingerprints The operator who, once registered, uses the product as a control unit
The product is of monolithic design (a single plastic housing) and is mounted by a nut (hand-tightened without the need for tools) in a standard 22 mm diameter hole. It operates on a 24 Vdc supply. The product connects to the power supply and to the control output (relay or PLC) with a 2 meter cable or with an M12 connector. It can be installed on a flat, horizontal, or vertical surface. Two protective covers are available (see table below)
One to protect the active face of the sensing screen. This cover is attached with a self-adhesive hinge One made of 12 gauge stainless steel designed to cover the entire switch which protects the entire switch from the outdoor environment (rain, sleet, snow, sunlight, UV protection). It also gives some protection from someone trying to break into the switch
Description
The product consists of a dark gray housing, with the following on its front face:
XB5 SB
A sensing screen (1) that allows the registration of fingerprints and subsequent recognition of the registered fingerprints A green LED output state indicator (2), which illuminates when the output is activated (N.O. solid state contact) An orange LED (3), indicating an administrators Registration mode An orange LED (4), indicating an operators Registration mode A red Reset LED (5), which indicates in Delete mode that the administrator is deleting all or part of the memory A red LED (6) which flashes to indicate an unrecognized fingerprint or incorrect operation
ZB5 SZ70
Mounting nut, 22 mm Legend plate, 28 x 7 mm, self-adhesive, blank, with black background, for engraving Mounting adapter Stainless-steel protective cover
ZB5SZ72
Discount Schedule
19-123
19
22 mm Push Buttons
Connections
1 (+) 3 (-) 4 Output Cable BU: Blue BN: Brown BK: Black PNP
+
BK/4
Figure 19.5:
Dimensions
39.7 1.56
22
54 2.13
mm Dim. = in.
0.057 1.45
42.3 1.67
19
PUSH BUTTONS AND OPERATOR INTERFACE
38.8 1.53
69.3 2.73
4.124 104.75
1.072 27.23
19-124
Table of Contents
Section 20
Electronic Sensors and Machine Cabling
Osisense Photoelectric Sensors
XUB Tubular Sensors
New! New!
XUBL Laser Sensors XUBT Sensors XUM Miniature XUK and XUX Compact XUN PhotoVirtu
New!
Ultrasonic Sensors
Accessories XUV Label Sensor XXV18 18mm 20-9 20-9 20-9 20-10 20-10 20-10 20-10 20-10 20-10 20-11
Osisense RFID
Radio Frequency Identification 20-12
20-1
20
Diffuse
Background suppression
For multi-mode models (XUM0, XUK0, XUX0, XUN0) programmable to function as Diffuse, Diffuse/Background Suppression, Polarized Retroreflective, or Thru-Beam Receivers, consult the factory.
Polarized retroreflective
Thru-beam
XUB Tubular Sensors Proximity diffuse Polarized retroreflective Retroreflective Thru-beam XUB XUB 18 plastic 18 metal 0.6 m (1.9 ft) 0.6 m (1.9 ft) 2 m (6.6 ft) 2 m (6.6 ft) 4 m (13.1 ft) 4 m (13.1 ft) 15 m (49 ft) 15 m (49 ft) M 18 x 1 M 18 x 1 P / M 18 x 46 P / M 18 x 46 Temperature range: -25 to +55 C (-13 to +131 F) Degree of protection (conforming to IEC 60529): IP65, IP67 (XUK: IP65)
Mounting (mm) Enclosure: M (metal), P (plastic) / Dimensions (mm) x L or W x H x D Setup LEDs Common characteristics
Sensors for DC Applications (Solid State Output: Transistor) Pre-cabled, PvR, L + (2 m) M12 connector Pre-cabled, PvR, L + (2 m) M12 connector Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price N.O. XUB5APANL2 93.00 XUB5APANM12 105.00 XUB5BPANL2 93.00 XUB5BPANM12 117.00 Proximity diffuse, adjustable N.C. XUB5APBNL2 93.00 XUB5APBNM12 105.00 XUB5BPBNL2 93.00 XUB5BPBNM12 117.00 N.O. XUB9APANL2 93.00 XUB9APANM12 105.00 XUB9BPANL2 103.50 XUB9BPANM12 117.00 Polarized retroreflective Receiver or N.C. XUB9APBNL2 93.00 XUB9APBN12 105.00 XUB9BPANL2 103.50 XUB9BPANM12 117.00 Transmitter/Receiver, N.O. XUB1APANL2 78.00 XUB1APANM12 88.50 XUB1BPANL2 87.00 XUB1BPANM12 99.00 3-wire PNP a Retroreflective N.C. XUB1APBNL2 78.00 XUB1APBN12 88.50 XUB1BPANL2 87.00 XUB1BPANM12 99.00 N.O. XUB2APANL2R 60.00 XUB2APANM12R 69.00 XUB2BPANL2R 67.50 XUB2BPANM12R 76.50 Thru-beam N.C. XUB2APBNL2R 60.00 XUB2APBN12R 69.00 XUB2BPANL2R 67.50 XUB2BPANM12R 76.50 Transmitter XUB2AKSNL2T 54.00 XUB2AKSNM12T 61.50 XUB2AKSNL2T 54.00 XUB2AKSNM12T 61.50 Supply voltage limits, min/max (V) including ripple 1036 1036 1036 1036 Switching frequency (Hz) 500 500 500 500 Common characteristics for DC versions Switching capacity, max (mA): 100 / Overload and short-circuit protection / LED output state a For version with NPN output, change P to N. For example: XUB1APANL2 would become XUB1ANANL2. Connection
Table 20.2:
Reflectors
Accessories
mm 24 x 21 80 50 x 50 Catalog No. XUZC24 XUZC80 XUZC50 $ Price 7.20 21.60 10.80
XUZC24
XUZC80
XUZC50
Catalog No.
$ Price
XUZA118
8.40
20
Plastic XUZA218 12.45
Cables
90
Straight
Suitable plug-in female connectors, including pre-wired versions 2 m long without LED Catalog No. XSZCS151 XSZCD111Y $ Price 25.50 Catalog No. XSZCS141 $ Price 22.50 21.00
M8 M12
21.00 XSZCD101Y
20-2
DS2
Discount Schedule
Table 20.3:
New!
Transmitter & Receiver Sensing Characteristics Sensing Range Sensing Frequency Power Requirements Supply Voltage Max. Load Environmental Operating Temperature Range Environmental Protection Ratings Construction Barrel Dimensions ( x L) Housing Material Connection Output Type Catalog No. PNP Programmable N.O./N.C. XUBLAPCNL2 NPN Programmable N.O./N.C. XUBLANCNL2 Transmitter Only PNP Receiver Only NPN Receiver Only Connection PNP Programmable N.O./N.C. XUBLAPCNM12 NPN Programmable N.O./N.C. XUBLANCNM12 Transmitter Only PNP Receiver Only NPN Receiver Only 18 mm x 66 mm, 18 mm x 72 mm
Transmitter
Receiver
Transmitter
Receiver
0 m to 100 m (0 m to 328 ft) 1500 12 Vdc to 24 Vdc 100 mA (10 to 30) / Reverse polarity overload, short circuit protection -10 to +45 C (14 to +113 F) IP67, NEMA 4X (indoor use only)
18 mm x 66 mm PBT Plastic
18 mm x 72 mm
18 mm x 66 mm, 18 mm x 72 mm
18 mm x 72 mm
Pre-cabled, PvC (2 m) $ Price Catalog No. 330.00 330.00 XUBLAKCNL2T $ Price XUBLBPCNL2 XUBLBNCNL2 200.00 200.00 M12 330.00 XUBLBPCNM12 330.00 XUBLBNCNM12 XUBLAKCNM12T 200.00 XUBLAPCNM12R 200.00 XUBLANCNLM12R 200.00 $ Price Catalog No. 330.00 XUBLAPCNL2R XUBLANCNL2R $ Price Catalog No. $ Price 330.00 330.00 XUBLBKCNL2T 200.00 Catalog No. XUBLBPCNL2R XUBLBNCNL2R $ Price 200.00 200.00
Table 20.4:
New!
Sensing Characteristics Sensing Range Sensing Frequency Power Requirements Supply Voltage Max. Load Environmental Operating Temperature Range Environmental Protection Ratings Construction Barrel Dimensions ( x L) Housing Material Connection Output Type 3-wire PNP Programmable N.O./N.C. 3-wire NPN Programmable N.O./N.C. Connection 3-wire PNP Programmable N.O./N.C. 3-wire NPN Programmable N.O./N.C. 0.0 mm to 1.4 mm (0 in. to 55.0 in.)
Polarized retroreflective 0.0 mm to 0.8 mm 0.0 mm to 1.4 mm (0 in. to 31.5 in.) (0 in. to 55.0 in.) 1000 12 Vdc to 24 Vdc 100 mA (10 to 30) / Reverse polarity, overload, short circuit protection 0 to +55 C (32 to +131 F) IP67 (cabled), IP65 NEMA 4X (indoor use only)
18 mm x 78 mm PBT Plastic
18 mm x 92 mm
DS2
Discount Schedule
20-3
20
Line of sight along case axis Line of sight 90 to case axis Line of sight along case axis Line of sight 90 to case axis Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price XUBTAPSNL2 189.00 XUBTAPSWL2 189.00 XUBTSPSNL2 215.00 XUBTSPSWL2 215.00 XUBTANSNL2 189.00 XUBTANSWL2 189.00 XUBTSNSNL2 215.00 XUBTSNSWL2 215.00 M12 XUBTAPSNM12 189.00 XUBTAPSWM12 189.00 XUBTSPSNM12 215.00 XUBTSPSWM12 215.00 XUBTANSNM12 189.00 XUBTANSWM12 189.00 XUBTSNSNM12 215.00 XUBTSNSWM12 215.00
Diffuse
For multi-mode models (XUB0) programmable to function as Diffuse, Diffuse/Background Background suppression Suppression, Polarized Retroreflective, or Thru-Beam Receivers, consult the factory.
Polarized retroreflective
Thru-beam
Sensors Usable Sensing Distance Mounting (mm) Enclosure: M (metal) P (plastic) / Dimensions (mm) x L or W x H x D Setup LEDs Common Characteristics Sensors for DC Applications (Solid State Output: Transistor) Connection Transmitter Proximity diffuse, adjustable b N.O. N.C. N.O. Polarized retroreflective Receiver or Transmitter/ Receiver, 3-wire PNP a Retroreflective N.C. N.O. Thru-beam N.C. Supply voltage limits, min/max (V) including ripple Switching frequency (Hz) Common characteristics for DC versions N.C. N.O. Pre-cabled, PvR, L=2 m XUM2AKSNL2T 96.75 XUM5APANL2 180.00 XUM5APBNL2 180.00 XUM9APANL2 180.00 XUM9APBNL2 180.00 XUM1APANL2 150.75 XUM1APBNL2 150.75 XUM2APANL2R 114.75 XUM2APBNL2R 114.75 1030 500 M8 connector XUM2AKSNM8T 110.25 XUM5APANM8 202.50 XUM5APBNM8 202.50 XUM9APANM8 202.50 XUM9APBNM8 202.50 XUM1APANM8 173.25 XUM1APBNM8 173.25 XUM2APANM8R 130.50 XUM2APBNM8R 130.50 1030 500 LED output state indicator and power on LED ( Catalog No. $ Price Pre-cabled, PvR, M12 connector Screw trmls, ISO L=2 m 16 chi.gland XUK2AKSNL2T XUK2AKSNM12T XUX0AKSAT16T 78.75 90.00 92.25 XUK5APANL2 XUK5APANM12 XUX5APANT16 157.50 180.00 225.00 XUK5APBNL2 XUK5APBNM12 XUX5APBNT16 157.50 180.00 225.00 XUK9APANL2 XUK9APANM12 XUX9APANT16 168.75 191.25 240.75 XUK9APBNL2 XUK9APBNM12 XUX9APBNT16 168.75 191.25 240.75 XUK1APANL2 XUK1APANM12 XUX1APANT16 141.75 162.00 202.50 XUK1APBNL2 XUK1APBNM12 XUX1APBNT16 141.75 162.00 202.50 XUK2APANL2R XUK2APANM12R XUX2APANT16R 121.50 137.25 168.75 XUK2APBNL2R XUK2APBNM12R XUX2APBNT16R 121.50 137.25 168.75 1030 1030 1036 500 500 500 indicator ( ): yes / power on LED ( ): yes Pre-cabled, L=2 m XUK2ARCNL2T 96.75 XUK5ARCNL2 186.75 XUK9ARCNL2 202.50 XUK1ARCNL2 168.75 XUK2ARCNL2R 144.00 20 / Screw trmls, ISO 16 chi.gland XUX0ARCTT16T 153.00 XUX5ARCNT16 216.00 XUX9ARCNT16 234.00 XUX1ARCNT16 195.75 XUX2ARCNT16R 162.00 20 / M12 connector XUX0AKSAM12T 110.25 XUX5APANM12 200.25 XUX5APBNM12 200.25 XUX9APANM12 213.75 XUX9APBNM12 213.75 XUX1APANM12 182.25 XUX1APBNM12 182.25 XUX2APANM12R 153.00 XUX2APBNM12R 153.00 1036 500 M12 connector XUN0AKSNM12T 200.25 XUN4APANM12 c 177.75 XUN9APANM12 177.75 XUN0APSNM12 200.25 XUN0ANSNM12 200.25 1036 500 ): yes Proximity diffuse Polarized retroreflective Retroreflective Thru-beam XUM Miniature Design 0.4 m (1.3 ft) 2 m (6.5 ft) 4 m (13.1 ft) 8 m (26.2 ft) direct: mounting centers 25.5, M3 screws P / 12 x 34 x 27 XUK Compact Design 50 x 50 1 m (3.2 ft) DC or AC 5 m (16.4 ft) DC or 4 m (13.1 ft)AC 9 m (29.5 ft) DC or 17 M (55.7 ft) AC 30 m (98 ft) DC or 20 m (65.6 ft) AC direct: mounting centers 40 x 40, M4 screws P / 18 x 50 x 50 XUX Compact Design 2.1 m (6.8 ft) 11 m (36 ft) 14 m (46 ft) 40 m (131.2 ft) direct: mounting centers 30/36 to 40/50/74, M5 screws P / 30 x 92 x 71 PhotoVirtu 0.3 m (1 ft) / 0.6 m (2 ft) 2 m (6.56 ft) 15 m (49.21 ft) M18 x 1 or direct centers 24.1, M3 screws P / 65 x 44 x18
Multi-current/multi-voltage sensors for AC/DC applications, 1036 Vdc / 20264 Vac including ripple on DC (relay output, 1 C/O, 3 A) Connection Transmitter Diffuse N.O. + N.C. N.O. + N.C. N.O. + N.C. N.O. + N.C. ) ) / power on LED (
20
ELECTRONIC SENSORS AND MACHINE CABLING
Receiver or T/R, Polarized retroreflective Transmitter/ Receiver Retroreflective Thru-beam Switching frequency (Hz) LED output state indicator( a b c
For version with NPN output, change P to N. For example: XUB1APANL2 would become XUB1ANANL2. XUN models are not adjustable. For versions with 0.6 m (2 ft) sensing distance, change 4 to 5. For example: XUN4APANM123 would become XUN5APANM12.
NOTE: M8 is not Snap-C compatible. See page 20-2 for suitable plug-in cables with female connectors.
20-4
DS2
Discount Schedule
XS Plastic Rectangular
Refer to Catalog 9006CT0101
Table 20.6:
Auto-Adaptable
A single product that automatically adapts to most environments. Accurate position detection via teach mode.
Sensors Nominal Sensing Distance Usable sensing distance S (mm) shielded/non-shielded Precision adjustment range (mm) shielded/non-shielded Mounting in metal Enclosure: M (metal) P (plastic) Temperature range Degree of protection (conforming to IEC 60529) Sensors for DC applications (3-wire) Dimensions (mm) H x W x L 3-wire PNP PNP NPN NPN N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C.
$ Price
Type C (40 x 40 mm) Catalog No. $ Price 25 mm 015 / 025 815 / 825 Shielded or non-shielded via Oscisense teach mode P -25 to 70 C (-13 to 158 F) Pre-cabled: IP68 (with connector: IP67)
$ Price
PNP PNP NPN NPN Supply voltage limits min/max (V) including ripple Switching capacity, max (mA) Reverse overload, short circuit protection LED output state indication / power on LED Voltage drop, closed state (V) at I nominal Switching frequency (Hz) 3-wire Sensors for AC or DC applications (2-wire) Dimensions (mm) H x W x L AC/DC without 2-wire short-circuit protection a
Connection: pre-cabled PvR (2 m) 26 x 26 x 13 40 x 40 x 15 XS8E1A1PAL2 120.00 XS8C1A1PAL2 XS8E1A1PBL2 120.00 XS8C1A1PBL2 XS8E1A1NAL2 120.00 XS8C1A1NAL2 XS8E1A1NBL2 120.00 XS8C1A1NBL2 Connection: M8 or M12 connector XS8E1A1PAM8 136.50 XS8C1A1PAM8 XS8E1A1PBM8 136.50 XS8C1A1PBM8 XS8E1A1NAM8 136.50 XS8C1A1NAM8 XS8E1A1NBM8 136.50 XS8C1A1NBM8 1036 1036 100 200 200 Vdc / 300 Vac 200 Vdc / 300 Vac yes / yes yes / yes <2 <2 200 1000
80 x 80 x 26 XS8D1A1PAL2 XS8D1A1PBL2 XS8D1A1NAL2 XS8D1A1NBL2 XS8D1A1PAM12 XS8D1A1PBM12 XS8D1A1NAM12 XS8D1A1NBM12 1036 200 200 Vdc / 300 Vac yes / yes <2 150
N.O. N.C.
N.O. AC/DC without short-circuit protection a N.C. Supply voltage limits min/max (V), including ripple on DC Switching capacity, max (mA) LED output state indication / power on LED Residual current, open state (mA) Voltage drop, closed state (V) at I nominal Switching frequency (Hz), AC / DC 2-wire
Connection: pre-cabled PvR (2 m) 26 x 26 x 13 40 x 40 x 15 XS8E1A1MAL2 132.00 XS8C1A1MAL2 XS8E1A1MBL2 132.00 XS8C1A1MBL2 Connection: 1/2" 20 UNF connector XS8E1A1MAL01U20 151.50 XS8C1A1MAL01U20 XS8E1A1MBL01U20 151.50 XS8C1A1MBL01U20 20264 20264 200 Vdc, 300 Vac 200 Vdc, 300 Vac yes / yes yes / yes < 1.5 < 1.5 < 5.5 < 5.5 50 / 1000 50 / 1000 a Requires a 0.4 A quick-blow fuse in series with the load.
80 x 80 x 26 XS8D1A1MAL2 XS8D1A1MBL2 XS8D1A1MAU20 XS8D1A1MBU20 20264 200 Vdc, 300 Vac yes / yes < 1.5 < 5.5 50 / 1000
Table 20.7:
Accessories
Straight Cat. No. XSZBE00 XSZBC00 $ Price 12.00 12.00 90o Cat. No. XSZBE90 XSZBC90 $ Price 12.00 12.00 Adapter plate for block-type sensors XSE / XSC / XSD Cat. No. XSZBE10 XSZBC10 XSZBD10 $ Price 12.50 15.00 16.50
DS2
Discount Schedule
20-5
20
XS Plastic Tubular
Refer to Catalog 9006CT0101
www.schneider-electric.us
Specifications Nominal Sensing Distance Usable sensing distance S (mm), shielded/non-shielded Precision adjustment range (mm), shielded/non-shielded Mounting in metal Enclosure: M (metal), P (plastic) Temperature range Degree of protection (conforming to IEC 60529)
18 mm 9 mm 06 / 09 36 / 39 Shielded or non-shielded via Oscisense teach mode M -25 to 70 C (-13 to 158 F) IP67
Sensors for DC applications (3-wire) Connection: M8 or M12 connector Catalog No. PNP N.O. XS612B2PAL01M12 a PNP N.C. XS612B2PBL01M12 a 3-wire NPN N.O. XS612B2NAL01M12 a NPN N.C. XS612B2NBL01M12 a Supply voltage limits min/max (V), including ripple 1036 Switching capacity max (mA) 100 Reverse polarity, overload, and short circuit protection yes LED output state indication / power on LED yes / yes Voltage drop, closed state (V) at I nominal <2 Switching frequency (Hz) 1000 a Pigtail cable (L + 0.25 m) with end-mounted remote control and M12 connector.
Catalog No. XS618B2PAL01M12 a XS618B2PBL01M12 a XS618B2NAL01M12 a XS618B2NBL01M12 a 1036 100 yes yes / yes <2 1000
Catalog No. XS630B2PAL01M12 a XS630B2PBL01M12 a XS630B2NAL01M12 a XS630B2NBL01M12 a 1036 100 yes yes / yes <2 1000
Table 20.9:
Accessories
Catalog No. $ Price
XSZBPM12
7.50
Mounting Bracket with Indexing Pin for Cylindrical Sensors M12 M18 M30
20
ELECTRONIC SENSORS AND MACHINE CABLING
Cables
90
Straight
Plug-in female connectors, including pre-wired versions 2 m long, without LED Catalog No. XSZCS111 XSZCD111Y XSZCK101Y $ Price 21.45 20.25 22.50 Catalog No. XSZCS101 XSZCD101Y XSZCK111Y $ Price 20.25 20.25 22.50
M8 M12 U20
20-6
DS2
Discount Schedule
XS Basic Series
Refer to Catalog 9006CT0101
Table 20.10:
Basic Series
Cylindrical, Stainless Steel Flush and Non-Flush Mountable Three-Wire, DC Supply, Solid-State Output Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Power Requirements Supply Voltage Max. Load Environmental Operating Temperature Range Environmental Protection Ratings Construction Output Type N.O. PNP N.O. NPN N.C. PNP N.C. NPN Pre-cabled (2 m) M8 connector M12 connector Pre-cabled (2 m) M8 connector M12 connector Pre-cabled (2 m) M8 connector M12 connector Pre-cabled (2 m) M8 connector M12 connector Housing Material -25 to 70 C (-13 to 158 F) IP67 Nickel Plated Brass Catalog No. XS106BLPAL2 XS106BLNAL2 XS106BLPBL2 XS106BLNBL2 $ Price 73.50 73.50 73.50 73.50 Catalog No. XS108BLPAL2 XS108BLPAM8 XS108BLPAM12 XS108BLNAL2 XS108BLNAM8 XS108BLNAM12 XS108BLPBL2 XS108BLPBM8 XS108BLPBM12 XS108BLNBL2 XS108BLNBM8 XS108BLNBM12 -25 to 70 C (-13 to 158 F) IP67 Nickel Plated Brass $ Price 82.50 88.50 88.50 82.50 88.50 88.50 82.50 88.50 88.50 82.50 88.50 88.50 Catalog No. XS208BLPAL2 XS208BLPAM8 XS208BLPAM12 XS208BLNAL2 XS208BLNAM8 XS208BLNAM12 XS208BLPBL2 XS208BLPBM8 XS208BLPBM12 XS208BLNBL2 XS208BLNBM8 XS208BLNBM12 $ Price 82.50 88.50 88.50 82.50 88.50 88.50 82.50 88.50 45.00 82.50 88.50 88.50 Catalog No. XS112BLPAL2 XS112BLPAM8 XS112BLPAM12 XS112BLNAL2 XS112BLNAM8 XS112BLNAM12 XS112BLPBL2 XS112BLPBM8 XS112BLPBM12 XS112BLNBL2 XS112BLNBM8 XS112BLNBM12 -25 to 70 C (-13 to 158 F) IP67 Nickel Plated Brass $ Price 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50 Catalog No. XS212BLPAL2 XS212BLPAM8 XS212BLPAM12 XS212BLNAL2 XS212BLNAM8 XS212BLNAM12 XS212BLPBL2 XS212BLPBM8 XS212BLPBM12 XS212BLNBL2 XS212BLNBM8 XS212BLNBM12 $ Price 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50 1224 (1036) Vdc w/reverse polarity, overload, and short circuit protection 50 mA 1224 (1036) Vdc w/reverse polarity, overload, and short circuit protection 50 mA 1224 (1036) Vdc w/reverse polarity, overload, and short circuit protection 100 mA 6.5 Plain Flush Mountable 1.5 mm (00.06 in.) 3000 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) M8 Flush Mountable 1.5 mm (00.06 in.) M8 Non-Flush Mountable 2.5 mm (00.10 in.) 3000 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) M12 M12 Flush Mountable Non-Flush Mountable 2.0 mm (00.08 in.) 4.0 mm (00.16 in.) 2000 Hz 1000 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz)
Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Power Requirements Supply Voltage Max. Load Environmental Operating Temperature Range Environmental Protection Ratings Construction Output Type Pre-cabled (2 m) N.O. M8 connector PNP M12 connector Pre-cabled (2 m) N.O. M8 connector NPN M12 connector Pre-cabled (2 m) N.C. M8 connector PNP M12 connector Pre-cabled (2 m) N.O. M8 connector NPN M12 connector Consult the factory for current pricing Housing Material
M18 M18 Flush Mountable Non-Flush Mountable 5.0 mm (00.20 in.) 8 mm (00.31 in.) 2000 Hz 250 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) 1224 (1036) Vdc w/reverse polarity, overload, and short circuit protection 100 mA -25 to 70 C (-13 to 158 F) IP67 Nickel Plated Brass Catalog No. XS118BLPAL2 XS118BLPAM8 XS118BLPAM12 XS118BLNAL2 XS118BLNAM8 XS118BLNAM12 XS118BLPBL2 XS118BLPBM8 XS118BLPBM12 XS118BLNBL2 XS118BLNBM8 XS118BLNBM12 $ Price 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50 Catalog No. XS218BLPAL2 XS218BLPAM8 XS218BLPAM12 XS218BLNAL2 XS218BLNAM8 XS218BLNAM12 XS218BLPBL2 XS218BLPBM8 XS218BLPBM12 XS218BLNBL2 XS218BLNBM8 XS218BLNBM12 $ Price 45.00 a 67.50 67.50 a 67.50 67.50 a 67.50 67.50 a 67.50
M30 M30 Flush Mountable Non-Flush Mountable 10 mm (00.39 in.) 15 mm (00.59 in.) 200 Hz 60 Hz 50 gn, duration 11 ms 26 gn, amplitude 2 mm (1055 Hz) 1224 (1036) Vdc w/reverse polarity, overload, and short circuit protection 100 mA -25 to 70 C (-13 to 158 F) IP67 Nickel Plated Brass Catalog No. XS130BLPAL2 XS130BLPAM8 XS130BLPAM12 XS130BLNAL2 XS130BLNAM8 XS130BLNAM12 XS130BLPBL2 XS130BLPBM8 XS130BLPBM12 XS130BLNBL2 XS130BLNBM8 XS130BLNBM12 $ Price 76.80 a 76.80 76.80 a 76.80 76.80 a 76.80 76.80 a 76.80 Catalog No. XS230BLPAL2 XS230BLPAM8 XS230BLPAM12 XS230BLNAL2 XS230BLNAM8 XS230BLNAM12 XS230BLPBL2 XS230BLPBM8 XS230BLPBM12 XS230BLNBL2 XS230BLNBM8 XS230BLNBM12 $ Price 76.80 a 76.80 76.80 a 76.80 76.80 a 76.80 76.80 a 76.80
Table 20.11:
Accessories
Sensor Body M8 M12 M18 M30 Catalog No. 9006PA08 9006PA12 9006PA18 9006PA30 $ Price 3.30 4.80 4.80 6.30
Cables 90 Plug-in female connectors, including pre-wired versions, 2 m long, without LED 2009 Schneider Electric All Rights Reserved Connector M8 M12 Catalog No. XSZCS111 XSZCD111Y $ Price 21.45 20.25 Straight Catalog No. XSZCS101 XSZCD101Y $ Price 20.25 21.00
DS2
Discount Schedule
20-7
20
Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Power Requirements Supply Voltage (w/protection against reverse polarity) Max. Load Environmental Operating Temperature Environmental Protection Construction Housing Material Output Type N.O., PNP Pre-cabled (2 m) M12 connector N.O., NPN Pre-cabled (2 m) M12 connector
M12 threaded M12 x 1 7 mm (00.28 in.) 2500 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) 1224 (1036) Vdc 200 mA -25 to 85 C (-13 to 185 F) IP67 (M12), IP68 (L2) Stainless Steel PPS
M18 threaded M18 x 1 12 mm (00.47 in.) 1000 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) 1248 (1058) Vdc 200 mA -25 to 85 C (-13 to 185 F) IP67 (M12), IP68 (L2) Stainless Steel PPS
M18 plain 12 mm (00.47 in.) 1000 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) 1224 (1036) Vdc 200 mA -25 to 85 C (-13 to 185 F) IP67 (M12), IP68 (L2) Stainless Steel
M30 threaded M30 x 1.5 22 mm (00.87 in.) 500 Hz 50 gn, duration 11 ms 25 gn, amplitude 2 mm (1055 Hz) 1248 (1058) Vdc 200 mA -25 to 85 C (-13 to 185 F) IP67 (M12), IP68 (L2) Stainless Steel
Catalog No. $ Price XS212SAPAL2 77.70 XS212SAPAM12 77.70 XS212AAPAL2 49.95 XS212AAPAM12 49.95 XS218SAPAL2 77.70 XS218SAPAM12 77.70 XS218AAPAL2 49.95 XS218AAPAM12 49.95 XS2L2SAPAL2 83.70 XS2L2SAPAM12 83.70 XS2L2SANAL2 83.70 XS2L2SANAM12 83.70 XS230SANAM12 86.55 XS230SANAL2 86.55 XS230SAPAM12 86.55 XS230SAPAL2 86.55
XS212SANAL2 XS212AANAL2 XS218SANAL2 XS218AANAL2 77.70 49.95 77.70 49.95 XS212SANAM12 XS212SANAM12 XS218SANAM12 XS218AANAM12 77.70 49.95 77.70 49.95
Table 20.13:
Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Power Requirements Supply Voltage (w/protection against reverse polarity) Max. Load Environmental Operating Temperature Environmental Protection Construction Housing Material Output Type N.O. Pre-cabled (2 m), non-flush mountable 1/2"-20 UNF connector, non-flush mountable
Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Power Requirements Supply Voltage Max. Load Environmental Operating Temperature Range Environmental Protection Ratings Connection Construction Housing Material Cable 3-wire / PNP / N.O. function / flush mountable 3-wire / NPN / N.O. flush mountable 4-wire / PNP / N.O./N.C. function / flush mountable Connector 4-wire / PNP / N.O./N.C. function / flush mountable
M12 threaded M12 x 1 M18 threaded M18 x 1 M30 threaded M30 x 1.5 2 mm (0.078 in.) 5 mm (0.197 in.) 10 mm (0.394 in.) 300 200 150 Conforming to IEC 60068-2-27: 30 gn, 11 ms Conforming to IEC 60068-2-6 10 gn, +/- 1 mm (f= 1055 Hz) 24 Vdc (10-30 Vac 200 mA -25 +70 C (-13 +158 F) IP67, NEMA 4x (Indoor Use Only), IP65 ( M12 and 18 PCM) Pre-cabled, PvC (2 m) Stainless Steel Catalog No. $ Price XT112S1PAL2 178.50 XT112S1NAL2 178.50 XT112S1PCL2 178.50 XT112S1PCM12 178.50 Nickel Plated Brass $ Price Catalog No. 186.00 XT130B1PAL2 186.00 XT130B1NAL2 186.00 XT130B1PCL2 186.00 XT130B1PCM12
20
ELECTRONIC SENSORS AND MACHINE CABLING
20-8
DS2
Discount Schedule
Ultrasonic Sensors
www.schneider-electric.us
Table 20.15:
New!
Table 20.16:
New!
75.00
Table 20.17:
Sensor Accessories
Teachable Pushbutton Accessory for Virtu Series Catalog No. XXZPB100 Python AC/DC Power Convertor Catalog No. XXZPM100M12 $ Price 148.50 $ Price 43.50
Table 20.18:
Mounting Brackets
Body Type M12 M18 M30 Catalog No. 9006PA12 9006PA18 9006PA30 $ Price 4.80 4.80 6.30
Table 20.19:
Type
Connector Cables
Sensor Suffix Connector Style Catalog No. $ Price Type Sensor Suffix Connector Style Straight 90 Straight 90 Straight 90 Straight 90 Straight 90 Catalog No. XSZCD101Y XSZCD111Y XSZCD1501Y XSZCD1511Y XSZCK111Y XSZCK101Y XSZCA101Y XSZCA111Y XSZCA901Y XSZCA911Y $ Price 20.25 20.25 33.75 33.75 22.50 22.50 27.00 27.00 24.75 24.75 Micro 6.6 ft (2 m) Cable, PVC Material DC 4 Pinwithout LED D, M12 DC 4 Pinwithout LED D, M12 DC 5 Pinwithout LED D, M12 DC 5 Pinwithout LED D, M12 AC/DC 3 Pinwithout LED K, U20 AC/DC 3 Pinwithout LED K, U20 Mini 6.6 ft (2 m) Cable, PVC Material DC 3 Pinwithout LED A, R3 DC 3 Pinwithout LED A, R3 AC/DC 3 Pinwithout LED A, R3 AC/DC 3 Pinwithout LED A, R3
DS2
Discount Schedule
20-9
20
NANO 6.6 ft (2 m) Cable, PVC Material Non-Locking DC 3 Pinwithout LED S, M8 DC 3 Pinwithout LED S, M8 Locking DC 3 Pinwithout LED S, M8 DC 3 Pinwithout LED S, M8 DC 4 Pinwithout LED S, M8 DC 4 Pinwithout LED S, M8 Self-assembled Connector Snap-C connector
Ultrasonic Sensors
Refer to Catalog 9006CT0101
www.schneider-electric.us
Table 20.20:
New!
Virtu VM1 and VM18 Sensing Characteristics Sensing Range 51508 mm (220 in.) Sensing 300 kHz Frequency Power Requirements Supply Voltage Supply Current 1224 Vdc 40 mA (excluding load)
Environmental Ratings Operating -30 to 70 C (-22 to 158 F) Temperature Environment NEMA 4X (indoor use only), IP67 Construction Barrel, xL Flat Profile, wxhxd Housing Material Transducer Output Type Output PNP Sourcing Proximity NPN Sinking PNP Sourcing NPN Sinking Output Off at LOE and P Dual-Level On at LOE Pump In Normally Open and P HLOE, Off at P Off at LOE and P Dual-Level On at LOE Pump Out Normally Open and P HLOE, Off at P PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. Cable VM1/18PNO VM1/18PNC VM1/18NNO VM1/18NNC VM1/VM18PTO VM1/VM18NTO Cable VM1/VM18PP10000 VM1/VM18NP10000 VM1/VM18PPI1000 VM1/VM18PPI1000 VM1/VM18PPI2000 VM1/VM18PPI2000 VM1/VM18PPO0000 VM1/VM18NPO0000 VM1/VM18PPO1000 VM1/VM18PPO1000 VM1/VM18PPO2000 VM1/VM18PPO2000 Quick Disconnect VM1/18PNOQ VM1/18PNCQ VM1/18NNOQ VM1/18NNCQ VM1/VM18PTOQ VM1/VM18NTOQ Quick Disconnect VM1/VM18PPI0000Q VM1/VM18NPI0000Q VM1/VM18PPI1000Q VM1/VM18PPI1000Q VM1/VM18PPI2000Q VM1/VM18PPI2000Q VM1/VM18PPO0000Q VM1/VM18NPO0000Q VM1/VM18PPO1000Q VM1/VM18PPO1000Q VM1/VM18PPO2000Q VM1/VM18PPO2000Q $ Price 18 x 1 x 77.62 mm (0.709 x 3.06 in.) 43.7 x 18 x 59.7 mm (1.72 x 0.70 x 2.35 in.) Valox Glass Epoxy
-30 to 70 C (-22 to 158 F) NEMA 4X (indoor use only), IP67 12 x 1 x 58 mm (0.47 x 2.3 in.) 7.62 x 33.0 x 19.05 mm (0.3 x 1.3 x 0.75 in.) ULTEM Glass Epoxy Catalog Number Cable Barrel a N.O. (PNP + NPN) SM300A46000 N.C. (PNP + NPN) SM300A46010 Connector - M8 N.O. (PNP + NPN) SM350A46000 139.50 N.C. (PNP + NPN) SM350A46010 Connector - M12 N.O. (PNP + NPN) SM380A46000 N.C. (PNP + NPN) SM380A46010 $ Price Cable Barrel a N.O., Pump-out, Off at LOE N.O., Pump-in, Off at LOE 208.50 N.O., Pump-out, Off at LOE N.O., Pump-in, Off at LOE N.O., Pump-out, Off at LOE N.O., Pump-in, Off at LOE SM302A42000 SM302A42010 Connector - M8 SM352A42000 SM352A42010 $ Price 238.50
0 to 60 C (32 to 140 F) NEMA 4X (indoor use only), IP67 18 x 1 x 79 mm (0.90 x 2.55 in.) 16.25 x 30 x 84.40 mm (1.182 x 0.640 x 3.322 in.) ULTEM Silicon Rubber Cable N.O. N.C. N.O. N.C. Barrel a SM600A21600 SM600A21610 Connector - M12 SM650A21600 SM650A21610 $ Price 487.50
253.50
520.50
253.50 $ Price Cable Pump-out latch Pump-out latch, HLOE 238.50 Pump-in latch Pump-in latch, HLOE Dual alarm, N.O. Dual alarm, N.O., HLOE Dual alarm, N.C. 169.00 Dual alarm, N.C., HLOE Connector - M12 Pump-out latch Pump-out latch, HLOE Pump-in latch 169.00 Pump-in latch, HLOE Dual alarm, N.O. Dual alarm, N.O., HLOE Dual alarm, N.C. Dual alarm, N.C., HLOE Barrel a SM602A60400 SM602A60403 SM602A60410 SM602A60413 SM602A60420 SM602A60423 SM602A60430 SM602A60433 Barrel a SM652A60400 SM652A60403 SM652A60410 SM652A60413 SM652A60420 SM652A60423 SM652A60430 SM652A60433 $ Price 502.50
618.00
$ Price
535.50
Output
Cable
Quick Disconnect
$ Price
Voltage 010 Vdc with Temperature Compensation For Direct/Inverse models, change VD or VI to VA. Dir, 0 V, LOEP Inv, 0 V, LOEP Dir, 10 V, LOEP Inv, 10 V, LOEP Dir, HLOE, 0 V, P Inv, HLOE, 0 V, P Dir, HLOE, 10 V, P Inv, HLOE, 10 V, P VM1/18VD0000 VM1/18PNO VM1/18VD1000 VM1/18VI1000 VM1/18VD2000 VM1/18VI2000 VM1/18VD3000 VM1/18VI3000 VM1/18VD0000Q VM1/18VI0000Q VM1/18VD1000Q VM1/18VI1000Q VM1/18VD2000Q VM1/18VI2000Q VM1/18VD3000Q VM1/18VI3000Q Cable Barrel a $ Price Current (available in Flat Profile only) Inverse slope SM606A44810FP Inverse slope, HLOE SM606A44813FP 702.00 Direct slope SM606A44811FP Direct slope, HLOE SM606A44816FP Connector - M12 Barrel a $ Price Voltage Inverse slope SM656A44800 Inverse slope, HLOE SM656A44803 619.50 Direct slope SM656A44801 Direct slope, HLOE SM656A44806 Voltage - Flat Profile Inverse slope SM656A44800FP Inverse slope, HLOE SM656A44803FP 619.50 Direct slope SM656A44801FP Direct slope, HLOE SM656A44806FP
20
ELECTRONIC SENSORS AND MACHINE CABLING
Analog a
208.50
Current 420 mA with Temperature Compensation For Direct/Inverse models, change CD or CI to CA Dir, 4 mA, LOEP VM1/18CD0000 VM1/18CD0000Q Inv, 4 mA, LOEP VM1/18CI0000 VM1/18CI0000Q Dir, 20 mA, LOEP VM1/18CD1000 VM1/18CD1000Q Inv, 20 mA, LOEP VM1/18CI1000 VM1/18CI1000Q 208.50 Dir, HLOE, 4 mA, P VM1/18CD2000 VM1/18CD2000Q Inv, HLOE, 4 mA, P VM1/18CI2000 VM1/18CI2000Q Dir, HLOE, 20 mA, P VM1/18CD3000 VM1/18CD3000Q Inv, HLOE, 20 mA, P VM1/18CI3000 VM1/18CI3000Q Flat profile models are available, add suffix FP to model. Consult the factory.
NOTE: LOE = at loss of echo, LOEP = at loss of echo and at power up, HLOE = hold on loss of echo, HLOEP = hold on loss of echo and at power up, Dir = direct, Inv = inverse, P = power up
2009 Schneider Electric All Rights Reserved
20-10
DS2
Discount Schedule
Ultrasonic Sensors
Refer to Catalog 9006CT0101
www.schneider-electric.us
Table 20.21:
New!
Virtu 30 mm Sensing Characteristics Sensing Range 1021000 mm (439 in.) Sensing 180 kHz Frequency Power Requirements Supply Voltage Supply Current 1224 Vdc, 1524 Vdc analog 60 mA (excluding load)
1224 Vdc discrete; 1524 Vdc analog 100 mA (excluding load) 0 to 50 C (32 to 122 F) discrete -20 to 60 C (-4 to 140 F) analog NEMA 4X (indoor use only), IP67 30 x 1 x 95 mm (1.18 x 3.74 in.) ULTEM Silicon Rubber or Fluorosilicone 1m/2m $ Price Description Connector Cable 253.50 2 m Connector Cable Cable 1 m a Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch Pump-in latch w/alarm Pump-in latch, w/setpoint 328.50 Dual setpoint Dual alarm Connector Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch Pump-in latch w/alarm Pump-in latch, w/setpoint Dual setpoint Dual alarm Cable 1 m a $ Price Voltage Auto slope Direct slope Inverse slope Current Auto slope Direct slope Inverse slope 358.50 Connector Voltage Auto slope Direct slope Inverse slope Current SM956A190000 SM956A130000 SM956A120000 SM956A180000 SM956A110000 SM956A100000 SM952A100000 SM952A150000 SM952A170000 SM952A110000 SM952A140000 SM952A160000 SM952A120000 SM952A130000 Catalog No. SM906A180000 SM906A110000 SM906A100000 SM906A190000 SM906A130000 SM906A120000 SM902A100000 SM902A150000 SM902A170000 SM902A110000 SM902A140000 SM902A160000 SM902A120000 SM902A130000 SM950A400000 SM900A400000 679.50 663.00 Catalog No. SM950A100000 SM900A100000
1224 Vdc discrete; 1524 Vdc analog 100 mA discrete; 80 mA analog (excluding load)
Environmental Ratings Operating 0 to 70 C (32 to 158 F) Temperature Environment NEMA 4X (indoor use only), IP67 Construction Barrel, xL 30 x 1 x 95.26 mm (1.18 x 3.75 in.) Housing Material PBT Valox 553 Transducer Glass Epoxy Output Type Description PNP Sourcing N.O. Proximity Output PNP Sourcing N.C. NPN Sinking N.O. NPN Sinking N.C. Connector Normally Open Hold on loss of echo; Off on power up PNP XX2V3A1PGM12 NPN XX2V3A1NGM12 Off on loss of echo; Off on power up PNP XX2V3A1PFM12 NPN XX2V3A1NFM12 Hold on loss of echo; Off on power up PNP XX2V3A1PJM12 NPN XX2V3A1NJM12 Off on loss of echo; Off on power up PNP XX2V3A1PHM12 NPN XX2V3A1NHM12 Catalog No. XX6V3A1PAM12 XX6V3A1PBM12 XX6V3A1NAM12 XX6V3A1NBM12
-20 to 60 C (-4 to 140 F) NEMA 4X (indoor use only), IP67 30 x 1 x 116 mm (9.18 x 4.58 in.) ULTEM Glass Epoxy 8m $ Price Description 633.00 Cable 616.50 Connector Catalog No. $ Price
Cable 8 m Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch 616.50 Pump-in latch w/alarm Pump-in latch, w/setpoint Dual setpoint Dual alarm Connector 633.00 Pump-out latch 880.50 Pump-out latch w/alarm Pump-out latch, w/setpoint 633.00 Pump-in latch Pump-in latch w/alarm 985.50 Pump-in latch, w/setpoint Dual setpoint 633.00 Dual alarm Cable 8 m $ Price Voltage 810.00 Auto slope Direct slope 705.00 Inverse slope Current Auto slope 705.00 Direct slope Inverse slope Connector Auto slope 720.00 Direct slope Inverse slope Current Auto slope 720.00 Direct slope Inverse slope SM956A890000 SM956A830000 1050.00 SM956A820000 SM956A880000 SM956A810000 1050.00 SM956A800000 Voltage SM906A890000 SM906A830000 1035.00 SM906A820000 Catalog No. $ Price SM952A800000 SM952A850000 SM952A870000 SM952A810000 988.50 SM952A840000 SM952A860000 SM952A820000 SM952A830000 SM902A800000 SM902A850000 SM902A870000 SM902A810000 972.00 SM902A840000 SM902A860000 SM902A820000 SM902A830000
Dual-Level Pump In
Quick Disconnect 020 mA Direct/Inverse slope Direct output Inverse output 420 mA Direct/Inverse slope Direct output Inverse output 05 VDC Direct/Inverse slope Direct output Inverse output 010 VDC Direct/Inverse slope Direct output Inverse output XX9V3A1F1M12 XX9V3A1G1M12 XX9V3A1H1M12 XX9V3A1F3M12 XX9V3A1G3M12 XX9V3A1H3M12 XX9V3A1A2M12 XX9V3A1D2M12 XX9V3A1E2M12 Catalog No. XX9V3A1A4M12 XX9V3A1D4M12 XX9V3A1E4M12
Analog
Auto slope Direct slope Inverse slope For the 2 m version, change model from SMxxxA1xxxxx to SMxxxA4xxxxx.
DS2
Discount Schedule
20-11
20
Electronic Tags Nominal Sensing Distance With Station XGCS49 With Station XGCS89 Dimensions (W x H x D) Memory Capacity Type of Memory Time (ms) Read a Write a Ordering Information 33 48
Cylindrical 18 20 M18 x 1 x 12 mm 256 EEPROM 12 + 0.825 x n 19 + 4.1 x n Catalog No. $ Price XGHB211345 52.50
9.25 + 375 x n 16.25 + 375 x n 12 + 0.825 x n 12 + 0.825 x n 12 + 0.825 x n 13 + 0.8 x n 20 + 0.8 x n 20 + 11.8 x n 12 + 5.6 x n 20 + 11.8 x n Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price XGHB444345 157.50 XGHB445345 195.00 XGHB90E340 15.00 XGHB320345 30.00 XGHB221346 67.50
Compact Stations, 13.56 MHz Dimensions (W x H x D) Protocols Normal Sensing Distance (depending on associated tag) Ordering Information
C Format 40 x 40 x 15
D Format 80 x 80 x 26 M12 Ethernet switch Catalog Number 20100 $ Price 900.00 Catalog Number XGCS8901201 $ Price 1185.00 TCSESU051F0 $ Price c
Connection boxes Protocols Associated compact stations Supply Voltage Ordering Information
Ethernet box Modbus TCP/IP XGCS49 and XGCS89 24 Vdc Catalog Number XGSZ33ETH $ Price 1312.50
Tap-off box Modbus, Uni-Telway and CANopen b XGCS49 and XGCS89 24 Vdc Catalog Number TCSAMT31FP $ Price c
Pre-Wired M12, 4-pin Female Connector, A Coding Size 2m Catalog No. XGSZX08L2 $ Price 15.00 30.00 22.50
5 m XGSZX08L5 10 m XGSZX08L10
For 13.56 MHz RFID diagnostics Read/Write operations on electronic tags and diagnostics on compact stations Microsoft Windows CE.NET Professional version 4.2 Catalog Number XGSTP401 $ Price 9075.00
Network T Connector M12, 1 Male/2 Female 5-pin, A Coding Catalog Number TCSCTN011M11F $ Price 67.50
20
ELECTRONIC SENSORS AND MACHINE CABLING
Table 20.23:
Ethernet Shielded Connecting Cable, ConneXium (2), Modbus Shielded Connection Cable, M12 Male D Coding/RJ45, 4-pin M12/SUB-D15, A Coding Length Catalog No. $ Price Length Catalog No. $ Price Length 1m TCSECL1M3M1S2 186.00 3m TCSECL1M3M3S2 240.00 5m TCSECL1M3M5S2 c 2m TCSMCN1FQM2 75.00 2m 10 m TCSECL1M3M10S2 450.00 40 m TCSECL1M3M40S2 1140.00 a n = number of 16-bit words b Uni-Telway and CANopen protocols available soon. c Call factory for current pricing.
$ Price
TCSMCN1F9M2P
97.50
20-12
DS2
Discount Schedule
Table of Contents
Section 21
Limit Switches
Encapsulated Miniature Industrial Snap Switches LIMIT SWITCHES
Part Numbers
9007A and 9007C
Basic Snap Switch without enclosures with or without operators Encapsulated switches with NEMA 6P rating and 10 A contacts Osisense Miniature metal modular Osisense Compact non-modular Osisense Compact metal modular Osisense Compact plastic modular Osisense Compact plastic with 2 side-cable entries and modular head Osisense Compact metal with manual reset Osisense Compact plastic with manual reset Osisense Component heads and lever arms Osisense Component bodies, cable plug assemblies, and cable glands Osisense Compact, plastic, non-modular
XCMD
9007MS, 21-8
9007A, p. 21-6
XCMN
XCKD
XCKP
XCKT
XCMD, 21-14
XCKD, 21-14
XCDR
XCPR
ZCE, ZCY
XCKP, 21-14
XCKT, 21-15
New! New!
21-18
XCKS
21-19
XCKL
Compact General Duty, metal, with direct opening contacts Oiltight, watertight switches, and compact types available Precision switches with direct acting contacts to meet most International standards Oiltight and foundry switches with 20 A contacts Oiltight mill and foundry switches with up to 3 circuits
XCKL, 21-20
9007C, p. 21-22
9007 Type C
21-31 21-33
L100/L300
XCKJ, 21-34
9007T, 21-31
L100, 21-33
21-1
21
21-14
Limit Switches
Product Panorama
Refer to Catalog 9006CT0101
www.schneider-electric.us
21
LIMIT SWITCHES
Features Head
Enclosure
Open, plastic A variety of operators are available. See page 21-6. Selected operators
Metal body, metal head Bottom or side cable entry. Full range of operating heads. See page 21-8. Operator
Metal
Metal
Metal 3 conduit entries Head, body, and lever 63 x 64 x 30 52 x 72 x 30 (2.48 x 2.52 x 1.18) (2.05 x 2.83 x 1.18) Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional a
Mounting by the body or by the head Head, body, lever, and connector CENELEC: EN 50047 31 x 65 x 30 (1.22 x 2.56 x 1.18)
40.1 x 44.4 x 15.8 30 x 50 x 16 (1.58 x 1.75 x 0.62) (1.18 x 1.97 x 0.63) Linear or rotary
Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional a Same heads for ranges XCMD, XCKD, XCKP and XCKT N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O. N.C. + N.C. + N.O. N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
Contact blocks 2 snap action contacts 2 snap action contacts 3 snap action contacts 3 snap action contacts 4 snap action contacts 4 snap action contacts 2 slow break contacts break before make 2 slow break contacts break before make 2 slow break contacts make before break 2 slow break contacts make before break 2 slow break contacts simultaneous 2 slow break contacts simultaneous 3 slow break contacts break before make 3 slow break contacts break before make 2 snap action contacts 4 snap action contacts N.C. + N.O., N.O. + N.O. N.C. + N.C., N.O. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
N.C. + N.C. + N.O. + N.O. N.C. + N.C. + N.O. + N.O. N.C. + N.O. N.C. + N.O. N.C. + N.C. + N.O. N.C. + N.C. + N.O. N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
Screw terminal: Screw terminal: Screw terminal Pre-cabled 400 V/6 A 2 contacts: 500 V/10 A 2 contacts: 500 V/10 A Insulation voltage (Ui) / 300 Vac/Vdc 2 contacts: 3 contacts: 400 V/6 A 3 contacts: 400 V/6 A See page 21-6 2 contacts: 10 A (standard) 3 contacts: 400 V/4 A Connector: Connector: thermal current (Ithe) 400 V/6 A 4 contacts: 400 V/3 A Integral M12, Integral M12, 4-pin: 250 V/3 A 5-pin: 60 V/4 A NEMA Types 1, 2, Enclosure rating NEMA Types 1, 2, 4, NEMA Types 1, 4X, 6, 12 NEMA Types 1, 2, 4, 6, NEMA Types 1, 2, 4, 6, None 6, 6P, 12, 13 2, 13 12, 13 12, 13 IP = IEC enclosure rating IP 66, IP 67, IP 68, 6P,66, IP 67, IK 04 IP67 IP 65, IK 04 IP IP 66, IP 67, IK 06 IK = EN shock test standard IK 06 Pre-cabled. Screw terminal: Pre-wired cable, Connector: M16, M20, PG 11, PG 13, 1/2" NPT, or PF 1/2 Screw terminal or M12 connector Pre-wired cable Integral or remote Electrical connection Faston connector option available M12 or remote 7/8" Connector: Integral M12 16UN a Flexible operators do not guarantee direct (positive) opening operation.
NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP 66, IK 06 Screw terminal: 3 entries for M20, PG 11, or 1/2" NPT Screw terminal: 1 entry incorporating cable entry or tapped 1/2" NPT
21-2
Limit Switches
www.schneider-electric.us
Product Panorama
Refer to Catalog 9006CT0101
Enclosure Features Modularity Conforming to standards / Product certifications Body dimensions (w x h x d), mm (in.)
Metal, diecast, zinc alloy Plug-in body Head, body, and lever UL 508, C22-2-14-95, NEMA 250, IEC 60947, EN 60947-1, EN 60947-5-1 Standard: 39 x 102 x 45 (1.54 x 4.02 x 1.77) Compact: 39 x 80 x 45 (1.54 x 3.15 x 1.77) Linear movement, plunger Rotary movement, lever Multi-directional movement (wobble stick, cat whisker) c
CENELEC: EN 50041
CENELEC: EN 50041
NEMA A600 UL508 UL Listed, CSA Certified 58.7 x 114.3 x 64.5 (2.31 x 4.5 x 2.54)
NEMA A600 UL508 UL Listed, CSA Certified 58.7 x 126 x 53.3 (2.31 x 4.95 x 2.10)
40 x 77 x 44 (1.57 x 3.03 x 1.73) 40 x 72.5 x 36 42.5 x 84 x 36 (1.67 x 3.31 x (1.57 x 2.85 x 1.42) 1.42) Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional c Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional c
Head Contact blocks 2 snap action contacts 2 snap action contacts 3 snap action contacts 3 snap action contacts 4 snap action contacts 4 snap action contacts 2 slow break contacts break before make 2 slow break contacts break before make 2 slow break contacts make before break 2 slow break contacts make before break 2 slow break contacts simultaneous 2 slow break contacts simultaneous 3 slow break contacts break before make 3 slow break contacts break before make 1 slow break contact Form Y1561 a 2 snap action contacts 4 snap action contacts
1 N.C 1 N.O. + 1 N.C. 2 N.O. + 2 N.C. ; 2 N.O. + 2 N.C. , neutral position; 2 N.O. + 2 N.C. , two stage Ui = 600 V, except: 9007C62, 9007C66, 9007C68 (Ui = 250 V) and 9007C84, 9007C86 (Ui = 125 V) Ithe = 10 A, except: 9007C84, 9007C86 (Ithe = 2.5 A)
N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.O. N.C. + N.O. N.O. + N.C. N.O. + N.C. N.C. + N.C. N.O. + N.O. N.C. + N.C. + N.O. ; N.C. + N.O. + N.O. N.C. + N.C. + N.O. ; N.C. + N.O. + N.O. 2 C/O Screw terminal 2 contacts: 500 V/10 A 3 contacts: 400 V/6 A Connector Integral M12, 5-pin: 60 V / 4 A Integral 7/8" 16UN: 250 V / 6 A NEMA Types 1, 2, 4, 12 IP 66, IK 07 Screw terminal 1 entry for ISO M20 or PG 13 conduit thread or 1/2" NPT
N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O. 2 C/O
600 V 20 A (AC/DC)
IP 67 conforming to IEC 60529, NEMA Types 2, 4, 6, 6P 12, 13 , Cable entry 1/2"-14 NPT, M20 x 1.5 ISO cable entry
IP 65, IK 03
NEMA Types 1, 4, 13 IP65, 66 Cable entry 1/2" NPT (metric available) Connector available
Electrical connection
a b c
Connector Connector 5-pin mini connector. Integral M12 or 7/8" 16UN Single pole only. Refer to page 21-26 for details. For other contact options, see catalog 9006CT0101. Flexible operators do not guarantee direct (positive) opening operation.
21-3
21
LIMIT SWITCHES
Application Data
Table 21.1:
Type 1 9007C 9007CR a a a a a a a a a a a a a a a 2 a a a 3 4 a a a a a a a a a a a a a a a a a a a a a a a a a a a a 4X 6 a a 6P a a a a 7 9 12 a a a 13 IP65 IP66 IP67 a a a a a a a a a a a a a a a a a a a a
Enclosure Ratings
NEMA Style IEC Style
21
LIMIT SWITCHES
9007FT L100/L300 9007MS/ML c 9007T XCKJ XCKL XCKN & XCNR XCKP & XCKT b XCKS, XCMN XCMD, XCKD a b c
Table 21.3: Ambient Temperature Ranges The low temperatures listed below are based on the absence of freezing moisture or water. Care should be taken to avoid sub-freezing temperatures where dripping or splashing water is present and to avoid bringing a cold switch into a warm humid atmosphere and then back into sub-freezing temperatures. The water or moisture can freeze around the switch lever arm or plunger and cause jamming
Type 9007 C Lever Type Plunger & Wobble Stick Type 9007 FTe, T HL100/HL300 L100/L300 9007 MS/ML XCKJ, XCKL, XCKP, XCKT XCMN, XCKN, XCNR XCKS XCMD e -20 F (-28.9 C) 0 F (-17.8 C) -10 F (-23 C) 0 F (-17.8 C) 0 F (-17.8 C) -4 F (-20 C) -13 F (-25 C) -13 F (-25 C) -13 F (-25 C) -13 F (-25 C) +185 F (+85 C) +185 F (+85 C) +185 F (+85 C) +350 F (+177 C) +200 F (+93 C) +221 F (+105 C) +158 F (+70 C) +158 F (+70 C) +158 F (+70 C) +158 F (+70 C) Low Temperature High Temperature at Full Rated Load
Indicates NEMA or IEC Type Rating available for each product. For indoor use onlynot UV protected. Enclosure ratings are NEMA 1, 2, 3, 4, 6, 6P, 12, and 13 except for option 21 (low force) which is NEMA 1 only. The 9007 MS/ML05 (omni-directional operation) enclosure ratings are NEMA 1, 2, 12, and 13.
The Type FT will withstand hot falling sand up to +300F (+149 C); however, ambient temperature for the FT switch is the same as the Type T above (+185 F, +85 C). Do not use in higher temperature ambients.
Table 21.2:
Type
Sealing
Material Standard shaft seals on lever types Viton fluorocarbon Neoprene d Nitrile (Buna N) d PVC Shaft seal Nitrile (Buna N) Nitrile (Buna N) Cellulose fiber laminate Nitrile (Buna N) Nitrile (Buna N) and silicon
Some switches are available with higher or lower temperature limits, by selecting special versions or special options. Refer to the respective product sections for further information. (Ex.: 9007MS/ML, see page 21-9.) Table 21.4: Electrical Contact Ratings
ACNEMA A600 Max. Current35% Power Factor Volts A 120 240 480 600 f 60 30 15 12 Make VA 7200 7200 7200 7200 Break A 6 3 1.5 1.2 VA 720 720 720 720 Continuous Volts Carrying Amperes 10 10 10 10 125 250 600 DC Maximum Current Make or Break A VA Continuous Carrying Amperes 5/2.5 f 2.5 2.5
9007C, CR R.B.Denison L
9007T and FT
Type C52 compact unit ratings at 125 Vdcsame ratings as C54, CF53 and CR53 at other voltages.
Table 21.5:
B
21 - 22 13 - 14 21 - 22 13 - 14
P
tripping resetting
21-22 13-14
0C
Make-before-break (overlapping) SPDT The normally open contact closes before the normally closed contact opens. Break-before-make (offset) SPDT The normally closed contact opens before the normally open contact closes. Simultaneous make and breakSPDT The normally closed contact opens at the same time as the normally open contact closes.
A=Maximum travel of the operator in mm or degrees. B=Tripping travel of the contact. C=Reset travel. D=B-C=Differential travel. P=Point from which positive opening is assured
Table 21.6:
Wiring Diagrams
Form A SPST-NO
Form B SPST-NC
Form C SPDT
Form AA DPST-NO
Form BB DPST-NC
Form CC DPDT
Form X SPSTNO-DB
Form Y SPSTNC-DB
Form Z SPDT-DB
Form XX DPSTNO-DB
Form YY DPSTNC-DB
Form ZZ DPDT-DB
21-4
Current Ratings
www.schneider-electric.us
Contact ConfigurationsDirect opening contacts meet IEC 60947-5-1 requirements. Table 21.7: Maximum Current Ratings for Control Circuit ContactsAll Types
AC50 or 60 Hz Switch Type Contacts Direct Opening Contacts Meet IEC 60947-5-1 Requirements a Inductive 35% Power Factor V A L100/L300 XCKD 2 Contacts XCKD 3 Contacts XCKJ Plug-in SPDT with 2 or 3 Contacts Form Z SPDT Form Zb 3 Pole Form Zb SPDT Form Z 2 SPDT Form ZZ SPDT Form Zb 2 SPDT Form ZZ SPDT Form Zb 2 Pole SPDT Form Zb 3 Pole Form Zb SPDT Form Zb 3 Pole Form Zb 2,3 or 4 Pole Form Zb SPDT Form Zb 2 Pole SPST, Form X or Y (rated 0.5 hp @ 110 and 200 Vac) SPDT, Form Z SPST, Form X or Y (rated 0.5 hp @ 110 and 200 Vac) SPDT, Form Z DPST Form AA or BB DPDT Form ZZ SPST Form Y1561 Slow break SPDT Form Z No 120 240 480 600 120 240 120 240 120 240 480 600 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 480 600 120 240 480 600 120 240 480 600 120 240 480 600 120 240 480 600 120 240 480 600 120 240 120 240 120 240 480 600 120 240 480 600 150 75 37.5 30 60 30 30 15 60 30 15 12 60 30 60 30 60 30 60 30 60 30 30 15 60 30 30 15 30 15 30 15 60 30 40 20 10 8 40 20 10 8 30 15 7.5 6 60 30 15 12 60 30 15 12 60 30 15 12 60.0 30.0 60.0 30.0 150 75 37.5 30 60 30 15 12 Make VA 18000 18000 18000 18000 7200 7200 3600 3600 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 3600 3600 7200 7200 3600 3600 3600 3600 3600 3600 7200 7200 4800 4800 4800 4800 4800 4800 4800 4800 3600 3600 3600 3600 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 7200 18000 18000 18000 18000 7200 7200 7200 7200 A 20 12.5 6.25 5 6 3 3 1.5 6 3 1.5 1.2 6 3 6 3 6 3 6 3 6 3 3 1.5 6 3 3 1.5 3 1.5 3 1.5 6 3 15 10 6 5 15 10 6 5 3 1.5 0.75 0.6 6 3 1.5 1.2 6 3 1.5 1.2 6 3 1.5 1.2 6.0 3.0 6.0 3.0 20 12.5 6.25 5 6 3 1.5 1.2 Break VA 2400 3000 3000 3000 720 720 360 360 720 720 720 720 720 720 720 720 720 720 720 720 720 720 360 360 720 720 360 360 360 360 360 360 720 720 1800 2400 2880 3000 1800 2400 2880 3000 360 360 360 360 720 720 720 720 720 720 720 720 720 720 720 720 720 720 720 720 2400 3000 3000 3000 720 720 720 720 Resistive 75% Power Factor Make and Break Amperes 6 3 1.5 1.2 6 3 3 1.5 6 3 1.5 1.2 6 3 6 3 6 3 6 3 6 3 3 1.5 6 3 3 1.5 3 1.5 3 1.5 6 3 15 10 6 5 15 10 6 5 3 1.5 0.75 0.6 6 3 1.5 1.2 6 3 1.5 1.2 6 3 1.5 1.2 20 12.5 6.25 5.0 6 3 1.5 1.2 V DC Inductive and Resistive Make and Break Amperes Single Pole 125 250 600 125 250 125 250 125 250 600 125 250 125 250 125 250 125 250 125 250 125 250 125 250 125 250 125 250 125 250 125 250 125 250 600 125 250 600 125 250 600 125 250 600 125 250 600 125 250 600 125 250 600 1.1 0.55 0.2 0.55 0.27 0.22 0.11 0.55 0.27 0.1 0.55 0.27 0.55 0.27 0.55 0.27 0.55 0.27 0.55 0.27 0.22 0.11 0.55 0.27 0.22 0.11 0.22 0.11 0.22 0.11 0.55 0.27 0.5 0.25 0.05 2.0 0.5 0.1 1.0 0.3 0.1 0.55 0.27 0.1 0.55 0.27 0.1 0.22 0.11 5.0 1.0 0.2 Double Pole 20/5 AC/DC Continuous Carrying Amperes
Yes Yes No No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes
0.25 0.1 0.5 0.2 0.02 0.2 0.1 0.22 0.11 0.22 0.11
10/2.5 5/1.0 10 10 10 10/2.5 10 10/2.5 10 10 10/2.5 10/2.5 5/1.0 10/2.5 5/1.0 5/1.0 5/1.0 10/2.5
XCKJ Non Plug-in XCKL XCKN XCKP 2 Contacts XCKP 3 Contacts XCKT 2 Contacts XCKT 3 Contacts XCMD 2-4 Contacts XCMN 2 Contacts XCNR
9007AO1, AC
No
15
No
15
No
10
No
10/2.5
9007C
No
10/2.5
DPDT Form ZZ 9007MS 9007ML SPDT Form C SPDT Form Z SPDT Quick Make and Break Form Z All Slow Make and Break Form Z
No
No No
No
9007T and FT
No
20
Simplified Version
Complete symbol
For contacts used in safety applications (end of travel, emergency stop device, etc.) the assurance of direct opening is required (see IEC 204, EN 60204 or NF C 79-130) after each test. The opening of the contact must be verified by testing with an impulse voltage (2500 V).
Note: Alternate Current RatingsSeveral product lines offer special versions or options with alternate contact configurations or contact materials, which may result in current ratings that differ from those listed above. Refer to the respective product sections for further information.
21-5
21
LIMIT SWITCHES
9007AO, 9007CO
Class 9007 / Refer to Catalog 9006CT0101
www.schneider-electric.us
21
Type AB21 LIMIT SWITCHES Type AO2 Type AP222 with 2358C22G6 mushroom button
Industrial snap switches have been incorporated in many Square D products such as timers, specialty push buttons, foot switches, operating mechanisms, door interlocks, motor control centers, limit switches, and many other control products. Recommended ActuatorAn adjustable actuator is recommended. If non-adjustable actuator is used, a resilient type or a mechanical stop should be used to prevent bottoming of button mechanism. Adjustable Actuator OvertravelMinimum recommended overtravel in both trip and reset directions is 0.015". Adjustable Actuator Total TravelMaximum differential limit plus 0.030" (Example: 0.076" for Type AO2). Non-Adjustable Actuator Total TravelFully retractedat least 0.139" for Type AO1 and 0.160" for Types AO2 and CO3 from mounting surface. Fully engagedat least 0.061" but not closer than 0.045" from mounting surface. Table 21.8:
Operator Style
CB35 (RH) 174.00 2 N.O. Operator Only AP202 c 60.00 2 N.C. CB36 (LH) 174.00 Single pole snap switches that contain two double break contact elements (1 N.O. and 1 N.C.) must be used on circuits of same polarity. Two pole snap switches contain two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of same polarity. Roller turned 90 from standard (perpendicular to mounting holes). For use with Type AO and CO basic switches.
Table 21.9:
Switch Type
Contacts d
Voltage A
Make VA A
Break VA
SPDT 120 40 4800 15 1800 15 125 15 Form Z 240 20 4800 10 2400 10 250 15 AO1, AC SPST e 480 10 4800 6 2880 6 600 15 Form X or Y 600 8 4800 5 3000 5 15 SPDT 120 40 4800 15 1800 15 125 15 AW, AO2, and AO6, Form Z 240 20 4800 10 2400 10 250 15 AB, AP SPST e 480 10 4800 6 2880 6 600 15 Form X or Y 600 8 4800 5 3000 5 15 DPDT 120 30 3600 3 360 3 125 10 AW, CO3, and CO6, Form ZZ 240 15 3600 1.5 360 1.5 250 10 CB, CC, CP DPST 480 7.5 3600 0.75 360 0.75 600 10 Form AA or BB 600 6 3600 0.6 360 0.6 10 d Do not meet IEC 60947-5-1 requirements for direct opening contacts. e Single-pole snap switches that contain two double-break contact elements (1 N.O. and 1 N.C.) must be used on circuits of the same polarity. Two-pole snap switches contain two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two doublebreak contact elements (1 N.O. and 1 N.C.) that must be used on circuits of the same polarity.
Acceptable Wire Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1422 AWG Recommended Terminal Clamp Torque . . . . . . . . . 69 lb-in (0.71.0 Nm)
21-6
CP1
Discount Schedule
0.19 4.8
0.19 4.8
2.5 63.5
.167 Max.
Mounting Surface
A B
1B 1A Pole 1
2A 2B Pole 2
Operating Data, in. (mm) AO1, 1A, 1B Pre-travel Differential Total travel Operating force 0.0570.074 (1.41.8) 0.0150.025 (0.60.6) 0.1030.125 2.63.2) 711 oz (0.050.08 N) AO2, 2A, 2B 0.0570.074 (1.41.8) 0.0350.046 (0.91.16) 0.1030.125 (2.63.2) 1014 oz (0.070.1 N) Pre-travel 1st stage Pre-travel 2nd stage Differential Total travel Operating force CO3
Operating Data, in. (mm) C07 0.0350.060 (0.91.5) 0.0600.085 (1.52.1) a 0.0100.020 (0.250.50) 712 oz (0.050.084 N)
a Separation between first and second stage trip points is 0.020.025 (0.50.6). Note: Shipping weight of Type AO and CO is 0.25 lb (0.11 kg).
9007AP301, 303, 304, 305, 321, 323, 324, 325, and CP321, 323, 324, 325
Note: Type AP321 shown.
Plunger to mount in 1/2" Dia. Hole in panels up to 0.38" (9.6mm) thick. .192
0.47" x 32 thread 2.20 55.9 0.39 9.9 A 2.5 63.5 .414 0.83 21.0 0.19 4.8 1.59 40.3
2.69 68.3
2.5 63.5
Dimension A 0.70 (17.8) 0.80 (20.3) Operating Data, in. (mm) AP221 CP221 0.0700.089 (1.82.2) 0.0250.046 (0.91.2) 0.1610.180 (4.14.6) 0.2310.269 (5.86.8) 712 oz (0.050.08 N)
Dimension A 0.70 (17.8) 0.80 (20.3) Operating Data, in. (mm) AP321, 324 AP323, 325 0.0600.150 (1.53.8) 0.0350.046 (0.91.2) 0.2000.340 (5.18.6) 28 oz (0.2 N) CP321, 324 0.0600.150 (1.53.8) 0.0250.046 (0.91.2) 0.2000.340 (5.18.6) 26 oz (0.18 N) CP323, 325 0.0600.150 (1.53.8) 0.0350.046 (0.91.2) 0.2000.340 (5.18.6) 28 oz (0.2 N)
0.0700.089 (1.82.2) 0.0350.046 (0.91.2) 0.1610.180 (4.14.6) 0.2310.269 (5.86.8) 1014 oz (0.070.1 N)
CP1
Discount Schedule
21-7
21
.330 .310
1.03 26.2
Mounting Surface
0.31 7.9
1.14 29.0
LIMIT SWITCHES
1.06 27.0
.167 Max.
Encapsulated Miniature
The heavy-duty, miniature MS limit switch is completely encapsulated and intended for difficult applications such as machine tools, earth moving equipment, and general transportation. The switch has 40 mm mtg hole centers. Table 21.10:
Temperature range Enclosure rating Vibration resistance Shock resistance Contact Characteristics Rated thermal current Rated insulation voltage Gold contact switching ratings Cable
9007MS/ML Miniature
Class 9007 / Refer to Catalog 9006CT0101
www.schneider-electric.us
21
LIMIT SWITCHES
Electrical Ratings/SPDT Form C (MS Type) MS Circuit - Form C 1 N.O.1 N.C. Silver Contacts Vac Make Break 120 60 A 6A 240 30 A 3A 10.0 Amperes Continuous DC Contact Rating: 5 A (Res), 28 Vdc Gold Contacts 100 mA @ 125 Vac 30 mA 28 Vdc
Specifications
-4 F to +221 F (-20 C to +105 C) The minimum temperatures listed are based on the absence of freezing moisture or water. For -40 F / -40 C minimum temperature, see Forms 21 and 80 in Table 21.13 on page 21-9. NEMA 1, 2, 4, 6, 6P 12, 13, IP67 , 10 G (751200 Hz) 35 G 10 A (standard) 300 Vac and Vdc (standard) 0.1A, 24 Vdc; 0.24 VA #18 AWG SJTO
Electrical Ratings/SPDT-DB Form Z (ML Type) Silver Contacts Vac Make Break 120 60 A 6A 240 30 A 3A 10.0 Amperes, Continuous DC Contact Rating: 5 A (Res), 28 Vdc
Table 21.11:
.070" max. Bk-Rd Bk-W Bk-Rd Bk-W 0 .004" max. .19" min. Bk-Rd Bk-W Bk-Rd Bk-W 0
.080" max.
80 oz 80 oz
.03" max.
.19" min.
80 oz
80 oz 80 oz
.03" max.
.19" min.
80 oz
80 oz 80 oz
.03" max.
.19" min.
80 oz
15 in-oz 15 in-oz
Silver Gold
MS05S0100 MS05G0100
172.00 186.00
80 oz 80 oz
.03" max.
.19" min.
80 oz
80 oz 80 oz
.03" max.
.19" min.
80 oz
80 oz 80 oz 80 oz
.03" max.
.19" min.
80 oz 80 oz
.03" max.
.19" min.
80 oz
a b
See available options on page 21-9. Add to the end of the catalog number. Up to three options may be added, if applicable. If the application includes oil, booted switches are recommended. See page 21-9.
File CCN
E42259 NKCR
File Class
LR 25490 3211-03
21-8
Discount Schedule
9007MS/ML Miniature
Class 9007 / Refer to Catalog 9006CT0101
Table 21.12:
.070" max. Bk-Rd Bk-W Bk-Rd Bk-W 0 .004" max. .19" min. Bk-Rd Bk-W Bk-Rd Bk-W 0
.080" max.
80 oz 80 oz
.03" max.
.19" min.
80 oz
80 oz 80 oz
.03" max.
.19" min.
80 oz
80 oz 80 oz
152.00
.03" max.
.19" min.
80 oz
194.00
a b
See available options below. Add to the end of the catalog number. Up to three options may be added, if applicable. See Table 21-9 for conductor length selection.
Table 21.13: Conductor Length and General Options Designators: 9007MS01Sxxyy Replace xx and yy in the catalog number above with the designators in the tables below. Some combinations of cable lengths and options are unavailable; consult Schneider Electric.
Conductor Length (xx)a No cable c 3 ftstandard 6 ft 9 ft 12 ft 18 ft 33 ft c Use with options 54, 55, 82 Designator $ Price Adder 00 01 02 03 04 05 13 8.60 19.60 28.40 48.00 130.00 General Options (yy) a #16 AWG SJTO cable (MS only) Side entrance #18 AWG SJTO cable Gray #18 AWG SJTO cable #18 AWG individual conductors Male 4 pin mini connector with 3 ft cable (MS only) Low force (18 oz), low temp (-40 F / -40 C ), NEMA 1 only High Pre-traveladds 0.030 Male 4 pin micro connector in housing (DC type) (MS only) Male 5 pin micro connector (DC type) (ML only) Low temperature (-40 F / -40 C), 9007MS04 (NEMA 1 only) Tapped holes in top of plunger housing (MS and ML) Male 4 pin micro connector in housing (AC type) (MS only) Black #18 AWG SJTO cable (ML only) Designator $ Price Adder 02 06 10 11 12 21 30 54 55 80 81 82 83 8.60 15.40 83.00 6.60 27.00 74.00 74.00 6.60 74.00
Table 21.14: Style 7 Levers.75" (19 mm) diameter, nylon or steel roller There are over 100 styles of levers to accommodate most of the industrial applications. They are made of zinc diecast. The roller levers are available with nylon rollers as standard and are also available with steel rollers or ball bearing roller (selected models only). Corrosion resistant models are also available. (9007 prefix is not required on lever catalog numbers)
Length Catalog Number 1/4" (6 mm) Wide Catalog Number 1/2" (13 mm) Wide Catalog Number 3/4" (19 mm) Wide Catalog Number 1" (25 mm) Wide Nylond 7J2N 7J3N 7J1N 7J7N 7J4N 7XJ2N 7XJ3N 7XJ1N 7XJ7N 7XJ4N List Price 19.60 19.60 19.60 19.60 32.80 19.60 19.60 19.60 19.60 32.80
inch (mm) Nylond Steel Nylond Steel Nylond 0.875 (22.23) 7A2N 7A2 7B2N 7B2 7F2N 1.375 (34.93) 7A3N 7B3N 7F3N 1.5 (38.10) 7A1N 7A1 7B1N 7F1N 1.75 (44.45) 7A7N 7B7N 7F7N 2.00 (50.8) 7A4N 7B4N 7F4N 0.875 (22.23) 7XA2N 7XA2 7XB2N 7XB2 7XF2N 7XB3N 7XF3N 1.375 (34.93) 7XA3N 1.5 (38.10) 7XA1N 7XA1 7XB1N 7XF1N 1.75 (44.45) 7XA7N 7XB7N 7XF7N 2.00 (50.8) 7XA4N 7XB4N 7XF4N d For corrosion-resistant nylon rollers, add S to the end of the catalog number. Price adder: 6.60. Note: Lever tightening torque for mounting the lever on the shaft: minimum 17 lb-in.
9007MS04S0084
Table 21.15:
Description Style 7D adjustable length 1-3/8" to 3-3/8"0.75" diameter, 1/4" wide, metal roller Style 7DN adjustable length 1-3/8" to 3-3/8"0.75" diameter, 1/4" wide, nylon roller Style 7S spring nylon, 6" rod, 0.3" diameter Style 7N nylon rod, 5" long, 0.3" diameter Note: Lever tightening torque for mounting the lever on the shaft: minimum 17 lb-in.
Discount Schedule
21-9
21
238.00
LIMIT SWITCHES
XCMD Modular
Refer to Catalog 9006CT0101
www.schneider-electric.us
21
LIMIT SWITCHES
1.
ZCE 63
ZCE F0
ZCE F2
ZCE G1
Spring rod
ZCE 08
Cats whisker
ZCE 06
ZCE 10
ZCE 11
ZCE 13
ZCE 14
Body with 2-pole N.C. + N.O. break before make, slow break contact
ZCM D25
Body with 3-pole N.C. + N.C. + N.O. break before make, slow break contact
ZCM D37
(1)
(1)
(1)
(1)
(1)
Pre-cabled connection components: replace the in the catalog number with the required cable length in meters, either: 1, 2, 3, 5, 7 or 10. Example: ZCMC21L becomes ZCMC21L7 for a 7 m (23.0 ft) cable. Note: only cable lengths of 1, 2 and 5 m (3.3, 6.6, and 16.4 ft) are available for pre-cabled connection components ZCMC37L and ZCMC39L.
21-10
XCMD Modular
Refer to Catalog 9006CT0101
Dimensions: mm (in.)
ZCY 53
ZCY 54
ZCY 55
ZCY 59
ZCY 22
ZCY 81
ZCY 91
ZCY 45
ZCY 46
ZCY 18
ZCY 19
ZCY 15
ZCY 16
ZCY 26
Pre-cabled bodies with 4-pole, N.C. + N.C. + N.O. + N.O. snap action contact
ZCM D41L1 ZCM D41L2 ZCM D41L5
Bodies with integral connector, with 2-pole snap action contact: N.C. + N.O., M12 5-pin connector
ZCM D21C12
Body with 7/8" 16UN 5-pin connector on 0.8 m (2.6 ft) flying lead, with 2-pole N.C. + N.O. snap action contact
ZCM D21L08U78
Body with M12 5-pin connector on 0.8 m (2.6 ft) flying lead, with 2-pole N.C. + N.O. snap action contact
ZCM D21L08R12
1.
Cannot be used on bodies ZCMD21, ZCMD29, ZCMD39, ZCMD41, ZCMD21C12, ZCMD21M12, ZCMD29C12, ZCMD21L08.
21-11
21
LIMIT SWITCHES
XCK Modular
Refer to Catalog 9006CT0101
www.schneider-electric.us
21
LIMIT SWITCHES
1. 2.
ZCE 21
ZCE 27
ZCE 28
ZCE 24
ZCE 62
ZCE 63
ZCE 64
ZCE 65
ZCE 66
ZCE H0
ZCE H2
Spring rod
Cats whisker
ZCE 02
ZCE 29
ZCE 07
ZCE 08
ZCE 06
ZCE 10
ZCE 11
ZCE 13
ZCE 14
ZCE 67
Plastic bodies with integral M12 connector, with: N.C. + N.O. snap action contact
Plastic bodies with contacts (1) for use with cable entry (see below)
ISO M16 x 1.5 Pg 11 1/2 NPT PG 11 conduit entries convert to 1/2" NPT using adapter DE9RA1012 (included)
ZCP EG11 Pg 11
For further details, see catalog 9006CT0101. Cannot be used on bodies: ZCD21, ZCP21, ZCT21, ZCD29, ZCP29, ZCD31, ZCP31, ZCD39.ZCP39, ZCD2M12, ZCP2M12.
21-12
XCK Modular
Refer to Catalog 9006CT0101
Dimensions: mm (in.)
ZCY 53
ZCY 54
ZCY 55
ZCY 59
ZCY 22
ZCY 81
ZCY 91
ZCY 49
ZCY 69
ZCY 44
Thermoplastic roller lever, track: 24/40 (0.94/1.57)
ZCE 01
ZCY 46
Steel ball-bearing mounted roller lever, track: 24/40 (0.94/1.57)
ZCY 48
Thermoplastic roller lever, track: 29/36 (1.14/1.42)
ZCY 39
Steel roller lever, track: 29/36 (1.14/1.42)
ZCY 18
Stay put, for actuation from left AND right (2) ZCE 09 Steel ball-bearing mounted roller lever, track: 29/36 (1.14/1.42)
ZCY 19
Thermoplastic roller lever, track: 21/44 (0.83/1.73)
ZCY 12
Steel roller lever, track: 21/44 (0.83/1.73)
ZCY 15
Steel ball-bearing mounted roller lever, track: 21/44 (0.83/1.73)
ZCY 16
ZCY 17
ZCY 25
Forked arm with rollers, 2 track, track: 25/39 (0.98/1.54)
ZCY 26
ZCY 23
Forked arm with rollers, 1 track, track: 32 (1.26)
ZCY 61
Metal bodies with integral M12 connector, with: N.C. + N.O. snap action contact ZCD 21M12 N.C. + N.C. snap action contact ZCD 29M12
ZCY 71
Metal bodies with contacts (1) for use in conjunction with cable entry (see below)
ZCD
ZCD EG11 Pg 11
21-13
21
LIMIT SWITCHES
BK
BU
BK BK WH BU BN
Actuation speed (in m/s) Switches conforming to IEC 60947-5-1 section 3 Degree of protection conforming to IEC 60529 Rated operational characteristics Cable entry Mounting holesin (mm) Body dimensionsin (mm) W x D x H
BK WH BN
13
14
22
21
13
14
Actuation speed (in m/s) 0.5 1 0.5 1.5 Switches conforming to yes yes yes yes IEC 60947-5-1 section 3 Degree of protection conforming to IP66 and IP67 IP66 and IP67 IP66 and IP67 IP66 and IP67 IEC 50 529 Rated operational Vac 15; A 300 (Ue = 240 V, Ie = 3 A) / Vdc 13; Q 300 (Ue = 250 V, Ie = 0.27 A) characteristics Cable entry 1 tapped entry for 1/2" NPT Mounting holes (mm) 20 20 M18 x 1 20 Body dimensions (mm) 30 x 30 x 73 30 x 30 x 73 30 x 30 x 73 30 x 30 x 73 WxDxH Ordering information Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
22
21
21
LIMIT SWITCHES
Miniature, Modular Limit Switches, Metal Table 21.16: XCMD Miniature Metal, Precabled
Steel Roller Plunger Plastic Roller Lever Variable Length Plastic Roller Lever M12 Head Steel Roller Plunger Cat Whisker End Plunger (not modular)
OsiSense
XCMD, XCMN
GN-YE
GN-YE
0.5 yes IP65 pre-cabled length = 1 m 0.79 (20) 1.18 x 0.63 x 2.32 (30 x 16 x 59) Cat. No. $ Price 92.00
Ordering information 2-pole, N.C. + N.O. XCMD2102L1 162.00 XCMD2115L1 snap action 2-pole, N.C. + N.O. XCMD2502L1 166.00 XCMD2515L1 break before make, slow break Exploded view, miniature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21-10
Vac 15; B 300 (Ue = 240 V, Ie = 1.5 A) / Vdc 13; R 300 (Ue = 250 V, Ie = 0.1 A) pre-cabled, adjustable direction, length = 1 m (other lengths available on request) 0.79 (20) 0.79 (20) 0.79 (20) 0.79 (20) 1.18 x 0.63 x 2.32 1.18 x 0.63 x 2.32 1.18 x 0.63 x 2.32 1.18 x 0.63 x 2.32 (30 x 16 x 59) (30 x 16 x 59) (30 x 16 x 59) (30 x 16 x 59) Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
0.79 (20) 1.18 x 0.63 x 2.32 (30 x 16 x 59) Cat. No. $ Price
142.00 XCMD2145L1 142.00 XCMD21F2L1 186.00 XCMD2106L1 144.00 XCMN2110L1 146.00 XCMD2545L1 146.00 XCMD25F2L1 186.00 XCMD2506L1 148.00
Compact, Modular Limit Switches, Metal or Plastic Table 21.17: XCKD and XCKP Compact, 30 mm Wide, Conforming to Standard EN 50047
Metal End Plunger Plastic Roller Lever Horizontal Actuation M18 Head Metal End Plunger Plastic Roller Lever Variable Length Plastic Roller Lever Rubber Roller Lever 50 mm Cat Whisker
OsiSense
XCKP
2-pole contact N.C. + N.O. snap action 2-pole contact N.C. + N.O. slow break
1.5 yes
1.5 yes
XCKD2510N12
83.00 XCKD2521N12 127.00 XCKD25H0N12 153.00 XCKD2518N12 101.00 XCKD2545N12 101.00 XCKD2539N12 107.00 XCKD2506N12 104.00
78.00 XCKP2545N12
78.00 XCKP2539N12
82.00 XCKP2506N12
80.00
21-14
Discount Schedule
OsiSense
XCKT 2-pole contact N.C. + N.O. snap action
13 21
Switches conforming to IEC 60947-5-1 section 3 Degree of protection conforming to IEC 60529 Rated operational characteristics Cable entry Mounting holesin (mm) Body dimensionsin (mm) W x D x H Ordering information Complete switch 2-pole, N.C. + N.O. snap action
Vac 15; A 300 (Ue = 240 V, Ie = 3 A) / Vdc 13; Q 300 (Ue = 250 V, Ie = 0.27 A) 2 tapped entries for 1/2" NPT 0.79 or 1.57 (20 or 40) 2.36 x 1.18 x 2.4 (60 x 30 x 61) Cat. No. XCKT2110N12 $ Price 62.00 0.79 or 1.57 (20 or 40) 2.36 x 1.18 x 2.4 (60 x 30 x 61) Cat. No. XCKT2102N12 $ Price 96.00 0.79 or 1.57 (20 or 40) 2.36 x 1.18 x 2.4 (60 x 30 x 61) Cat. No. XCKT2118N12 $ Price 76.00
OsiSense
XCDR and XCPR
Actuation speed (in m/s) Switches conforming to IEC 60947-5-1 section 3 Degree of protection conforming to IEC 60529 Rated operational characteristics Cable entry Mounting holesin (mm) Body dimensionsin (mm) W x D x H Ordering information
Vac 15; A 300 (Ue = 240 V, Ie = 3 A) / Vdc 13; Q 300 (Ue = 250 V, Ie = 0.27 A) 1 tapped entry for 1/2" NPT 0.79 (20) 0.79 (20) 0.79 (20)
1.18 x 1.18 x 3.74 (30 x 30 x 95) 1.18 x 1.18 x 3.74 (30 x 30 x 95) 1.18 x 1.18 x 3.74 (30 x 30 x 95) Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
XCDR Metal
2-pole, N.C. + N.O. snap action Complete switch 2-pole, N.C. + N.O. break before make, slow break XCDR2110N12 XCDR2510N12 143.00 143.00 XCDR2121N12 XCDR2521N12 143.00 153.00 XCDR2127N12 XCDR2527N12 143.00 153.00
Discount Schedule
21-15
21
0.5
0.5
1.5
LIMIT SWITCHES
14
22
21
LIMIT SWITCHES
Common Head and Levers for XCMD, XCKD, XCKP, XCKT Table 21.20: Metal Plunger and Multi-Directional Heads
Metal End Plunger with Elastomer Protective Boot Cat. No. ZCE11 $ Price 28.00
Plastic Roller Lever, Horizontal Actuation Cat. No. ZCE21 $ Price 52.00
Plastic Roller Lever, Vertical Actuation Cat. No. ZCE27 $ Price 52.00
Bushing Mounted
Bushing Mounted
Bushing Mounted
M12 Head Steel Roller Plungera Cat. No. ZCEF2 $ Price 72.00
M18 Head Steel Roller Plungera Cat. No. ZCEH2 $ Price 72.00
Spring Lever with Plastic End Cat. No. ZCE07 $ Price 34.00
Table 21.21:
Rotary Head without Lever, Spring Return, for Actuation from RH or LH Side Cat. No. ZCE01 $ Price 18.60
Rotary Head without Lever, Stay Put, for Actuation from RH or LH Side c Cat. No. ZCE09 $ Price 24.00
Plastic Roller Lever, Track: Steel Roller Lever, Track: Plastic Roller Lever, Track: Steel Roller Lever, Track: 24/31 mm (ZCMD) 24/31 mm (ZCMD) 16/39 mm (ZCMD) 16/39 mm (ZCMD) 29/36 mm (ZCD/P/T)b 29/36 mm (ZCD/P/T)b 21/44 mm (ZCD/P/T)b 21/44 mm (ZCD/P/T)b Cat. No. ZCY15 $ Price 14.00 Cat. No. ZCY16 $ Price 14.00 Cat. No. ZCY25 $ Price 14.00 Cat. No. ZCY26 $ Price 14.00
Plastic, Roller Lever, Track: 20/36 mm (ZCMD) 24/40 mm (ZCD/P/T)a Cat. No. ZCY18 $ Price 14.40
Steel Roller Lever, for Track: 20/36 mm (ZCMD) 24/40 mm (ZCD/P/T)a Cat. No. ZCY19 $ Price 14.00
Variable Length, Rigid Plastic Roller Lever Cat. No. ZCY45 $ Price 14.40
Variable Length, Bendable Plastic Roller Lever Cat. No. ZCY44 $ Price 14.00
Variable Length, Rigid Steel Roller Lever Cat. No. ZCY46 $ Price 14.00
Variable Length, Bendable Steel Roller Lever Cat. No. ZCY48 $ Price 14.00
$ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. 40.00 ZCY54 14.00 ZCY55 14.00 ZCY59 14.00 ZCY61 28.00 ZCY71 Recommended for use with body ZCD... / ZCP... / ZCT... Recommended for use with body: ZCMD... Cannot be used on bodies ZCMD21, ZCMD29, ZCMD39, ZCMD41, ZCMD21C12, ZCMD21M12, ZCMD29C12, ZCMD21L08.
21-16
Discount Schedule
NOTE: Metal components must be used with metal bodies. Plastic components must be used with plastic bodies. Table 21.22: Miniature, Metal Body/Contact Assemblies
LIMIT SWITCHES
Type of contact 2-pole N.C. + N.O. Snap action 2-pole N.C. + N.C. Snap action 3-pole N.C. + N.C. + N.O. Snap action 4-pole N.C. + N.C. + N.O. + N.O. Snap action 2-pole N.C. + N.O. Slow break 3-pole N.C. + N.C. + N.O. Slow break 2-pole N.C. + N.O. Snap action 5-pin connector 1 SPDT contact Snap action 4-pin connector
BU
BK
BU
BK
BU
RD
BU
RD
BU
BU
BK
BK
BK
BK
GN-YE
GN-YE
GN-YE
GN-YE
GN-YE
GN-YE
BK WH RD WH BN
BK WH RD WH BN
BK WH BN
BK WH BN
Metal body
$ Price 85.00
$ Price 85.00
BK WH BN
$ Price 86.00
$ Price Cat. No. $ Price Cat. No. $ Price 110.00 ZCMD21C12 124.00 ZCMD21M12 124.00
Table 21.23:
Specific pre-cabled connection components Length (m) 1 2 5
3
1
$ Price
Cat. No.
Table 21.24:
Type of contact
13
13
13
21
13
21
13
BK WH BN
13
21
13
31
21
31
21
14
14
14
22
14
22
21
14
14
22
14
22
32
Metal Plastic
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price ZCD21 54.00 ZCD29 54.00 ZCD39 76.00 ZCD25 62.00 ZCD37 87.00 ZCD21M12 122.00 ZCP21 33.90 ZCP29 33.90 ZCP39 45.90 ZCP25 37.70 ZCP37 52.00 ZCP21M12 57.00 ZCT21P16 44.00 ZCT25P16 50.00
Table 21.25:
Interchangeable cable entry
32
22
Metal Plastic
Note: Plastic conduit entries shown. Order plastic conduit entries for plastic bodies (XCKP/ZCP). Order metal conduit entries (chrome color) for metal bodies (XCKD/ZCD). Metal conduit entries do not fit on plastic bodies. Exploded view, compact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21-12
22
22
21
Discount Schedule
21-17
21
13
21 22
2 pole snap action Thermoplastic roller-lever plunger Plastic roller plunger Plastic roller plunger for lateral cam for cross cam Horizontal actuation Vertical actuation in approach approach in 1 direction 1 direction By 30 cam
14
13
21
2 pole break before make, slow break
Switch actuation
14
22
13
21
14
13
21
22
14
22
13
21
14
11
21
22
12
22
21
LIMIT SWITCHES
On end
Type of actuation
Maximum actuation speed Minimum force of torque For tripping For positive opening
Weight, kg (lb) Ordering Information (sold in packs of 20) 2 pole N.C. + N.O. snap action 2 pole N.C. + N.O., break before make, slow break 2 pole N.C. + N.C. snap action
0.5 m/s (1.64 ft/s) 15 N (3.37 lb) 30 N (6.75 lb) 0.065 (0.143) Cat. No. $ Price XCKN2110P20 29.00 XCKN2510P20 32.00 XCKN2910P20 29.00
0.3 m/s (0.99 ft/s) 12 N (2.70 lb) 20 N (4.50 lb) 0.065 (0.143) Cat. No. $ Price XCKN2102P20 46.00 XCKN2502P20 49.00 XCKN2902P20 46.00
0.065 (0.143) Cat. No. $ Price XCKN2103P20 46.00 XCKN2503P20 49.00 XCKN2903P20 46.00
0.1 m/s (3.28 ft/s) 6 N (1.35 lb) 10 N (2.25 lb) 0.070 (0.154) Cat. No. $ Price XCKN2121P20 46.00 XCKN2521P20 49.00 XCKN2921P20 46.00
0.070 (0.154) Cat. No. $ Price XCKN2127P20 46.00 XCKN2527P20 49.00 XCKN2927P20 46.00
Switch actuation
Rotary, Rotary, variable Multi-directional, thermoplastic length, thermoplastic spring rod roller-lever, 50 mm roller-lever, 50 mm By any moving part
Type of actuation
Maximum actuation speed For tripping Minimum force of torque For positive opening Weight, kg (lb) Ordering Information (sold in packs of 20) 2 pole N.C. + N.O. snap action 2 pole N.C. + N.O., break before make, slow break 2 pole N.C. + N.C. snap action
1.5 m/s (4.92 ft/s) 0.1 Nm (0.89 lb-in) 0.15 Nm (1.33 lb-in) 0.085 (0.187) 0.090 (0.198) 0.110 (0.243) 0.115 (0.254) Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price XCKN2118P20 36.00 XCKN2145P20 36.00 XCKN2139P20 38.00 XCKN2149P20 38.00 XCKN2518P20 XCKN2918P20 39.00 XCKN2545P20 40.00 XCKN2945P20 39.00 XCKN2539P20 41.00 XCKN2939P20 41.00 XCKN2549P20 41.00 XCKN2949P20
1 m/s (3.28 ft/s), any direction 0.13 Nm (0.11 lb-in) 0.085 (0.187) 0.075 (0.165) Cat. No. $ Price Cat. No. $ Price XCKN2108P20 37.00 XCKN2106P20 37.00 40.00 XCKN2506P20 40.00 XCKN2906P20 40.00 40.00
Table 21.27:
2 pole N.C. + N.C. Metal end plunger On end Plastic roller plunger By 30 cam
Switch actuation
Type of actuation
Maximum actuation speed Minimum force of torque For tripping For positive opening
Weight, kg (lb) Ordering Information (sold in packs of 20) 2 pole N.C. + N.O.snap action 2 pole N.C. + N.O. break before make, slow break 2 pole N.C. + N.C. snap action
0.5 m/s (1.64 ft/s) 15 N (3.37 lb) 30 N (6.74 lb) 0.080 (0.18) Cat. No. XCNR2110P20 XCNR2510P20 XCNR2910P20
0.3 m/s (0.99 ft/s) 12 N (2.70 lb) 20 N (4.50 lb) 0.080 (0.18) Cat. No. $ Price XCNR2102P20 35.00 XCNR2502P20 38.00 XCNR2902P20 38.00
0.1 m/s (3.28 ft/s) 6 N (1.35 lb) 10 N (2.25 lb) 0.085 (0.19) Cat. No. XCNR2121P20 XCNR2521P20 XCNR2921P20
0.090 (0.20) $ Price Cat. No. 55.00 XCNR2127P20 59.00 XCNR2527P20 59.00 XCNR2927P20
1.5 m/s (4.92 ft/s) 0.1 Nm (0.89 lb-in) 0.15 Nm (1.33 lb-in) 0.100 (0.22) Cat. No. $ Price XCNR2118P20 42.00 XCNR2518P20 47.00 XCNR2918P20 47.00
Table 21.28:
Cable entry
P20 PG 11 1/2 NPT Other cable entries Other Contact Configurations Function Diagrams
21-18
Discount Schedule
New!
Table 21.29:
Conforming to standards Approvals Ambient air temperature Vibration resistance Shock resistance Electric shock protection Degree of protection Repeat accuracy Cable entry Materials
Table 21.30:
13 21
14
13
21
22
14
11
21
22
2-pole N.C. + N.O. break before make, slow break Elastomer roller lever, 50 mm (1.97 in.) c Cat. No. XCKS139 $ Price 110.00 Variable length thermoplastic roller lever c Cat. No. XCKS141
12
Ordering Informationb
2-pole N.C. + N.O. snap action (XE2SP2151) 2-pole N.C. + N.O. break before make, slow break (XE2NP2151) 2-pole N.C. + N.C. snap action (XE2SP2141) 2-pole N.C. + N.C. simultaneous, slow break (XE2NP2141) Weight, kg (lb) Contact operation
22
$ Price 110.00
XCKS501
115.00
XCKS502
115.00
XCKS531
115.00
XCKS539
115.00
XCKS541
110.00
110.00
110.00
110.00
115.00
115.00
115.00
115.00
0.095 (0.209)
0.105 (0.231)
0.145 (0.320)
0.150 (0.331)
0.155 (0.342)
N.C. contact with positive opening operation, when properly mounted and using a conforming operator
Table 21.31:
Switch actuation
Specifications
On end By 30 cam
Type of actuation
Maximum actuation speed Minimum force or torque Cable entry a b c d e For tripping For positive opening
0.5 m/s (1.64 ft/s) 15 N (3.37 lb) 45 N (10.12 lb) 12 N (2.70 lb) 36 N (8.09 lb)
1.5 m/s (4.92 ft/s) 0.15 Nm (1.33 lb-in) 0.3 Nm (2.66 lb-in)
1 entry tapped M20 x 1.5 mm for ISO cable entry, clamping capacity 7 to 13 mm (0.28 to 0.51 in.) To convert PG 13 to 1/2" NPT, use adapter DE9RA1212. For ISO M20 x 1.5, add H29 to the end of the catalog number. Example: XCKS101 becomes XCKS101H29. Form conforming to EN 50041. See page 409 of catalog 9006CT0101R5/04. Switches with gold contacts or eyelet type connections: please consult your local sales office. Adjustable throughout 360 in 5 steps, or in 90 steps by reversing the notched washer. Adjustable throughout 360 in 5 steps, or in 45 steps by reversing the lever mounting. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
Discount Schedule
21-19
21
21
LIMIT SWITCHES XCKL110 XCKL10011 XCKL115 XCKL110 XCKL102
XCKL XCKL is a compact, general-duty limit switch for applications such as machine tools and material handling. Table 21.32: Specifications
-13 to +158 F (-25 to +70 C) The minimum temperatures listed are based on the absence of freezing moisture or water. NEMA Type 1, 2, 3, 4, 12 IP66 25 G (10500 Hz), conforming to IEC 68-2-6 50 G, conforming to IEC 68-2-27 0.002" (0.05 mm) 1/2" NPT standard Conforms to IEC 947-5-1 duty categories, AC15 and DC 13 10 A 300 Vac and dc (A300 and Q300) 25 m 2 x #16 AWG (1.5 mm2) per terminal 10 A fuse type SC. Outside U.S. use gl or N.
Temperature range Enclosure rating Vibration resistance Shock resistance Repeatability Cable entry Related Power Contact Characteristics Rated thermal current Rated insulation voltage Contact resistance (max.) Cable (max.) Short circuit protection (customer supplied)
Description a Programmable head CW and/or CCWsnap action DELRIN roller leveradjustable in 5 or 45 in increments (reversible mounting).
Operating Torque/Force 14.2 in-oz 14.2 in-oz 14.2 in-oz 14.2 in-oz 21.3 in-oz 21.3 in-oz 25.3 in-oz 25.3 in-oz
Contact Configuration SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow
Catalog Number XCKL10011 XCKL50011 XCKL10041 XCKL50041 XCKL115 XCKL515 XCKL121 XCKL521
58(P)
90
26
58(P)
Table 21.34:
Description a
Omnidirectional
Functional Diagram
30 21-22 13-14 21-22 13-14 0 14
Contact Configuration SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow
Table 21.35:
Plunger Operated
Functional Diagram
.07 .18(P) 21-22 13-14 21-22 13-14 0 .035 .217
Descriptiona
Contact Configuration SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow SPDT (N.O. + N.C.) snap SPDT (N.O. + N.C.) slow
Rod plunger
.07
.177(P)
Roller plunger
File CCN
E39281 NKCR
File Class
LR44087 3211-03
Acceptable Wire Sizes: 1424 AWG Recommended Terminal Clamp Torque: 13 lb-in
21-20
Discount Schedule
XCKL Components
Refer to Catalog 9006CT0101
Table 21.36:
BodiesElectric
Contacts Silver Gold Flashed Silver Catalog Number ZCKL1 ZCKL18 ZCKL5 $ Price 66.00 112.00 66.00
ZCKL1, ZCKL5
Table 21.37:
Rotary Heads
Components Contacts Catalog Number $ Price Programmable headb CW and/or CCW Select lever arm separately ZCKG00 66.00 Offset DELRIN roller levera ZCKD15 22.00 Offset steel roller levera ZCKD16 22.00 Offset ball-bearing roller levera ZCKD17 48.00 a Replacement arms are not available separately. Order complete head as a replacement. b See page 21-20.
Examples: Body Head ZCKL1 + ZCKD15 = XCKL115 Body Head ZCKL5 + ZCKD02 = XCKL502 Body Head Lever ZCKL1 + ZCKG00 + ZCKY11 = XCKL10011 Note: Some combinations are not available as complete switches.
ZCKG00 ZCKD15,16,17
ZCKD10 ZCKD02
Description Rod plunger Booted rod plunger Roller plunger Booted roller plunger One-way leverDELRIN roller Steel roller
Table 21.39:
Omnidirectional Heads
ZCKD21,23
Description Catalog Number $ Price Cat whiskersteel rodc ZCKD06 35.00 Wobble springsteel springc ZCKD08 35.00 c Replacement cat whiskers and wobble extensions are not available separately. Order complete head as a replacement.
Table 21.40:
ZCKY11 ZCKY43
Replacement Parts
Catalog Number XESP2151 XENP2151 XESP2158 $ Price 48.00 55.00 69.00
Description Contact block for ZCKL1 Contact block for ZCKL5 Gold flashed contact block for ZCKL18
Table 21.41:
ZCKY51 ZCKY71
Levers (For use with ZCKG00 heads only. These arms will not fit ZCKD___ heads.)
ZCKY81
ZCKY91
Description Size Adjustmente Increments Catalog Number $ Price DELRIN roller 0.9 in. diameter, 0.2 in. wide, 1.6 in. long 5 or 45 ZCKY11 15.40 Steel roller 0.9 in. diameter, 0.2 in. wide, 1.6 in. long 5 or 45 ZCKY13 15.40 Ball bearing roller 0.9 in. diameter, 0.2 in. wide, 1.6 in. long 5 or 45 ZCKY14 41.40 Adjustable length 0.74 in. diameter, 0.2 in. wide, 4.2 in. long (max.) 5 or 90 ZCKY41 15.40 DELRIN rollerd Steel roller 0.74 in. diameter, 0.2 in. wide, 4.2 in. long (max.) 5 or 90 ZCKY43 15.40 Steel rod, squared 1/8 in. side, 5.4 in. long (max.) 5 or 45 ZCKY51 15.40 Fiberglass rod, roundd 1/8 in. diameter, 5.4 in. long (max.) 5 or 45 ZCKY52 15.40 Steel rod, roundd 1/8 in. diameter, 5.4 in. long (max.) 5 or 45 ZCKY53 15.40 Plastic rod, roundd 1/4 in. diameter, 8.4 in. long (max.) 5 or 45 ZCKY59 15.40 Fork, 2 track DELRIN roller 0.9 in. diameter, 0.2 in. wide for ZCKE092 5 or 45 ZCKY71 28.40 Coil spring lever d 4.41 in. (112 mm) 5 or 45 ZCKY81 15.40 Spring rod leverd 7.05 in. (179 mm) 5 or 45 ZCKY91 15.40 d Flexible operators do not guarantee positive opening operation. e Reverse mounting (for ZCKG00 head)The higher increment (45 or 90) is a positive opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the N.C. contact even if the lever is loosely mounted on the head shaft. Acceptable Wire Sizes: 1424 AWG Recommended Terminal Clamp Torque: 13 lb-in
ZCKG00 Programming
The ZCKG00 head is field convertible to CW, CCW, or CW/CCW.
File CCN
42259 NKCR
File Class
LR25490 3211 03
Discount Schedule
21-21
21
Table 21.38:
Plunger Heads
LIMIT SWITCHES
Components Body Single pole, double break 1 N.O. + 1 N.C. Snap action, positive opening, same polarity Body 1 N.O. + 1 N.C., single pole double break Slow make, slow break isolated
9007C
Class 9007 / Refer to Catalog 9006CT0101
www.schneider-electric.us
CW
21
LIMIT SWITCHES
Oiltight, Watertight SwitchesStandard and Compact Bodies Table 21.42: All Type C Switches Are Rated NEMA 6P and UL Type 6P
Side Plunger Rotary Lever Arm Select Turret Head Standard Pre-travel Spring Return Low Differential Spring Return Neutral Position Standard Pre-travel Spring Return CW & CCW Type $ Price C68T10 266.00 CR67T10 473.00 T10 65.00 10 90 4 90 4 lb-in (0.45 Nm) 0.002" (0.05 mm) Low Differential Spring Return CW & CCW Type $ Price C68T5 287.00 CR67T5 485.00 T5 80.00 5 90 2 90 4 lb-in (0.45 Nm) 0.002" (0.05 mm) Light Operating Torque Spring Return CW & CCW a Type $ Price C54N2 255.00 C62N2 297.00 C66N2 341.00 C52N2 255.00 CR53N2 428.00 CR61N2 473.00 CR65N2 513.00 N 108.00 10 10 2-1/2 90 4 90 25 in-oz (0.18 Nm) 0.002" (0.05 mm) Side RollerPlunger Spring Return Vertical Roller b Type Side PushRod Plunger Spring Return Side PushRod Plunger Adjustablec Spring Return Side PushRod Plunger Maintained Contact
Maintained Contact
CW & CCW a Select Basic Switch Contacts 1 N.O. 1 N.C. 2 N.O. 2 N.C. 2 N.O.2 N.C. Neutral Position 2 N.O.2 N.C. Two Stage 1 N.O. 1 N.C. 1 N.O. 1 N.C. 2 N.O. 2 N.C. 2 N.O.2 N.C. Neutral Position 2 N.O. 2 N.C. Two Stage Type $ Price C54B2 210.00 C62B2 255.00 C66B2 297.00 C52B2 210.00 CR53B2 383.00 CR61B2 428.00 CR65B2 473.00 B 65.00 10 10 2-1/2 90 4 90 4 lb-in (0.45 Nm) 0.002" (0.05 mm)
CW & CCW a Type $ Price C54A2 225.00 C62A2 266.00 C66A2 333.00 C52A2 225.00 CR53A2 396.00 CR61A2 441.00 CR65A2 485.00 A 80.00 5 5 1-1/2 90 2 90 4 lb-in (0.45 Nm) 0.001" (0.03 mm)
CW (Trip) CCW (Reset) Type $ Price C54C 255.00 C62C 297.00 C52C 255.00 CR53C 428.00 CR61C 473.00 C 108.00 45 90 3 lb-in (0.34 Nm) 0.002" (0.05 mm) Type $ Price C54F 273.00 C62F 318.00 C66F 350.00 C52F 273.00 CR53F 449.00 CR61F 480.00 CR65F 521.00 F 131.00 Type $ Price C54G 248.00 C62G 291.00 C66G 315.00 C52G 248.00 CR53G 422.00 CR61G 462.00 CR65G 507.00 G 101.00 0.08" (2 mm) 0.08" (2 mm) 0.02" (0.5 mm) 0.25" (6.3 mm) 0.03" (0.8 mm) 4 lb (0.45 Nm) Type $ Price C54GD 260.00 C62GD 302.00 C66GD 350.00 C52GD 261.00 CR53GD 435.00 CR61GD 480.00 CR65GD 521.00 GD 116.00 Type $ Price C54H 291.00 C62H 333.00 C52H 291.00 CR53H 462.00 CR61H 507.00 H 144.00 0.14" (3.6 mm) 0.25" (6.3 mm) 7 lb (0.80 Nm)
Compact Box Plug-in UL Listed for Hazardous Location Division I Class I Groups B, C, D Class II Groups E, F, G
Head Only (Example: 9007B) Pre-travel First Stage First to Second Stage Total Travel Differential Reverse Overtravel Operating Torque/Force 1 Pole & 2 Pole Repeat Accuracy Linear travel of cam (1-1/2" lever arm) Pretravel Two Stage Nominal Operating Data
Acceptable Wire Sizes: 1222 AWG Recommended Terminal Clamp Torque: 7 lb-in (0.80 Nm)
To order basic switch and head less the plug-in receptacle base, substitute the letters CO for the first C in the type number. Example: Open type replacement for Type C54B2 is Type CO54B2. a These devices are factory set to operate the contacts in both the CW and CCW directions. Mode of operation is field convertible to CW only or CCW only. To order factory converted devicesfor CCW only operation, change the 2 at the end of the type number to 1 (Example: C54B2 becomes C54B1); for CW only operation, delete the 2 at the end of the type number (Example: C54B2 becomes C54B). b Can be converted to horizontal roller type in the field. To order horizontal roller version add the letter H at the end of the equivalent vertical roller version type number (Example: C54F would become C54FH). c To lock the nut in the desired position, crimp the slot near the bottom of the nut.
/CCW CW
CCW
CW
/C C W
Lever arms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 21-24, 21-25 Electrical ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 21-5 Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 21-25, 21-26
21-22
CP1
Discount Schedule
9007C
Class 9007 / Refer to Catalog 9006CT0101
Table 21.43:
Contacts 1 N.O. 1 N.C. 2 N.O. 2 N.C. 2 N.O.2 N.C. Neutral Position 2 N.O.2 N.C. Two Stage 1 N.O. 1 N.C. 1 N.O. 1 N.C. 2 N.O. 2 N.C. 2 N.O.2 N.C. Neutral Position 2 N.O.2 N.C. Two Stage
Type $ Price C54D 248.00 C62D 291.00 C66D 333.00 C52D 248.00 CR53D 422.00 CR61D 462.00 CR65D 507.00 D 101.00
Type $ Price C54E 233.00 C62E 273.00 C66E 318.00 C52E 233.00 CR53E 404.00 CR61E 449.00 CR65E 491.00
Type $ Price C54ED 248.00 C62ED 291.00 C66ED 333.00 C52ED 248.00 CR53ED 422.00 CR61ED 462.00 CR65ED 507.00
Type $ Price C54Ra 233.00 C62Ra 273.00 C66Ra 318.00 C52Ra 233.00 CR53Ra 404.00 CR61Ra 449.00 CR65Ra 491.00 Ra 87.00
Type $ Price C54JKC 203.00 C62JKC 255.00 C66JKC 297.00 C52JKC 210.00 CR53JKC 383.00 CR61JKC 428.00 CR65JKC 473.00 JKC 65.00
Type $ Price C54J 233.00 C62J 273.00 C66J 318.00 C52J 233.00 CR53J 404.00 CR61J 449.00 CR65J 491.00
Type $ Price C54K 233.00 C62K 273.00 C66K 318.00 C52K 233.00 CR53K 404.00 CR61K 449.00 CR65K 491.00
Type $ Price C54KC 233.00 C62KC 273.00 C66KC 297.00 C52KC 233.00 CR53KC 404.00 CR61KC 449.00 CR65KC 491.00 KC 87.00
Type $ Price C54L 174.00 C62L 216.00 C66L 273.00 C52L 174.00 CR53L 350.00 CR61L 390.00 CR65L 435.00 L 28.70 20 20 5 90 6 7 in-oz (0.05 Nm)
Type $ Price CO54 134.00 CO62 161.00 CO68 174.00 CO66 203.00 CO52 117.00
Type $ Price CT54 28.80 CT62 28.80 CT62 28.80 CT62 28.80 CT52 28.80
Compact Box Plug-in UL Listed for Hazardous Location Division I Class I Groups B, C, D Class II Groups E, F, G Head Only
Pre-travel First Stage First to Second Stage Total Travel Differential Reverse Overtravel Operating Torque/ Force 1 Pole and 2 Pole Repeat Accuracy Linear travel of cam Pretravel Two Stage Nominal Operating Data
E ED 87.00 101.00 0.08" (2 mm) 0.08" (2 mm) 0.01" (0.06 mm) 0.25" (6.3 mm) 0.02" (0.5 mm) 3 lbs. (0.34 Nm) 0.001" (0.03 mm)
Plug-in Replacement Units Acceptable Wire Sizes: 1222 AWG Recommended Terminal Clamp Torque: 7 lb-in (0.80 Nm)
To order the basic switch and head without the plug-in receptacle base, substitute the letters CO for the first C in the type number. Example: Open type replacement for Type C54D is Type CO54D. a Price does not include mushroom button. Must be ordered separately. See Table 21.44. b To lock the nut in the desired position, crimp the slot near the bottom of the nut. c DELRIN is a registered trademark of DuPont. Not for use outdoors. d Wobble stick extensions are available separately for the universal head or as replacements for complete devices.See Table 21.45.
Table 21.44:
Table 21.45:
1-3/8" Dia. Button Color Type No. Black 2358C6G3 Red 2358C6G2 Green 2358C6G6 Yellow 2358C6G8 Note: See Type C palm-operated switches.
Type C
File CCN
E42259 NKCR
File Class
LR25490 3211-03
Type CR
File CCN
E10054 NOIV
File Class
LR26817 3218-02
Compact Body
Hazardous Location
Standard Body
CP1
Discount Schedule
21-23
21
LIMIT SWITCHES
21
LIMIT SWITCHES
Lever Arms for 9007AW and 9007C Heavy Duty / Industrial Limit Switches Standard roller is hardened oil-impregnated sintered iron. Bold face Type numbers indicate the most commonly used lever arms. Table 21.46: Cast Zinc Lever Arms
Roller Length of Arm (A) 7/8" 1-3/8" 1-1/2" 2" 2-1/2" 3" Standard 3/4" Dia. (B) 1/4" Wide (C) Type BA11 MA11 CA11 DA11 EA11 $ Price 21.50 21.50 35.60 35.60 35.60 Standard 3/4" Dia. (B) 5/8" Wide (C) Type BA12 MA12 CA12 DA12 EA12 $ Price 35.60 35.60 35.60 35.60 35.60 Standard 5/8" Dia. (B) 1/4" Wide (C) Type AA1 BA1 MA1 CA1 DA1 EA1 $ Price 35.60 21.50 21.50 35.60 35.60 35.60 Standard 5/8" Dia. (B) 5/8" Wide (C) Type AA2 BA2 MA2 CA2 DA2 EA2 $ Price 35.60 35.60 35.60 35.60 35.60 35.60 Nylon 3/4" Dia. (B) 1/4" Wide (C) Type BA18 MA18 CA18 DA18 EA18 $ Price 21.50 21.50 35.60 35.60 35.60 Nylon 5/8" Dia. (B) 1/4" Wide (C) Type AA8 BA8 MA8 CA8 DA8 EA8 $ Price 35.60 21.50 21.50 35.60 35.60 35.60 Nylon 5/8" Dia. (B) 5/8" Wide (C) Type AA17 BA17 MA17 CA17 DA17 EA17 $ Price 35.60 35.60 35.60 35.60 35.60 35.60 Nylon a 1" Dia. (B) 5/8" Wide (C) Type BA13 MA13 CA13 DA13 EA13 $ Price 35.60 35.60 35.60 35.60 35.60
Standard 3/4" Dia. (B) 1/4" Wide (C) Roller on Opposite Side to Standard
Standard 5/8" Dia. (B) 1/4" Wide (C) Roller on Opposite Side to Standard
Standard 5/8" Dia. (B) 5/8" Wide (C) Roller on Opposite Side to Standard
Without Roller
Standard 3/4" Dia. (B) 1/4" Wide (C) (Countersunk Roller Pin)
Cable Operated With Eyebolt (3/8" I.D.) Instead of Roller Type MA22 $ Price 35.60
Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price 7/8" AA9 50.00 AA5 35.60 AA6 35.60 AA0 35.60 1-3/8" BA4 50.00 BA9 50.00 BA15 21.50 BA5 21.50 BA6 35.60 BA0 35.60 1-1/2" MA4 50.00 MA9 50.00 MA15 21.50 MA5 21.50 MA6 35.60 MA0 35.60 MA31 21.50 2" CA4 50.00 CA9 50.00 CA15 35.60 CA5 35.60 CA6 35.60 CA0 35.60 CA31 35.60 2-1/2" DA4 50.00 DA9 50.00 DA15 35.60 DA5 35.60 DA6 35.60 DA0 35.60 DA31 35.60 3" EA4 50.00 EA9 50.00 EA15 35.60 EA5 35.60 EA6 35.60 EA0 35.60 Recommended in place of Types BA7, CA7, DA7, EA7 and MA7 lever arms with steel rollers. If necessary, the latter arms can be furnished at $48.00 each.
Table 21.47:
Table 21.48:
0.156 3.96
0.09 2.29
LA6
LA3
LA18
LA12
35.60
LA9
50.00
Cast Zinc Lever Arm Dimensions A = Length of Lever Arm B = Roller Diameter C = Roller Width D = C + 5/16"
See price tables for A, B and C dimensions. Approximate shipping weights range from 1/8 to 1/4 lb. Table 21.49: One-Way Cast Zinc Roller Lever Arm
Roller, 1-1/4" Dia. (B) 1/4" Wide (C) Length of Arm 1-3/8" 1-1/2" 2" 2-1/2" 3" Cast Arm Type BA3 MA3 CA3 DA3 EA3 $ Price 64.00 64.00 64.00 64.00 64.00 Flat Steel Arm Type BA3S CA3S DA3S EA3S $ Price 64.00 64.00 64.00 64.00
Table 21.51:
Table 21.50:
Length of Arm
Table 21.52:
Type FA2
$ Price 71.00
1-1/2" 5"
RA11
Rod, in. (mm) 10 (254) Stainless Steel Rod 12 (304) Spring Rod, Steel 18 (304) Spring Rod, Steel 12 Spring Rod, DELRIN Looped Rod Arm 90 Forked Rod 2-1/2" Spring Rods, Steel
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21-25
21-24
CP1
Discount Schedule
Lever Arms
Standard roller is hardened oil-impregnated sintered iron. Bold face type numbers indicate the most commonly used lever arms. Table 21.53: Adjustable Length Lever Arms
Roller Standard Standard Nylon Ball Brg. Nylon a DELRIN Description Without 5/8" Dia. 5/8" Dia. 5/8" Dia. 1" Roller 1/4" Wide 5/8" Wide 1/4" Wide $ Price 11/16" Dia. 5/8" Dia. 1-5/8" Dia. $ Price 1/4" Wide Wide 1/4" Wide Type Non-bendable Bendable a HA0 HA9 Type HA1 HA5 Type HA2 HA6 Type HA4 HA8 35.60 35.60 Type HA24 HA25 Type HA22 HA23 Type HA20 50.00 Nylon 2" Dia. 1/4" Wide Rubber Tire 2-1/8" Dia. 1/2" Wide
C
3 _ _ _ _ _ _ _ _ _ _ 2 _ _ _ _ _ _ _ _ 1 _ _ _ _ _ _ _ _ _ _ 4
E D 0.35 9 A F
50.00 HA26
71.00 HA21
Recommended in place of Types HA3 and HA7 lever arms with steel rollers. If necessary these arms can be furnished at $50.00 each.
Table 21.54:
Length of Arm Roller Outside Type 7/8" 1-3/8" 1-1/2" 2" 2-1/2" 3" AA1M BA1M MA1M CA1M DA1M EA1M
0.87 22 0.67 17
0.38 10
1.05 0.84 27 21
Note: Roller can be changed in the field from roller outside to roller inside position or vice versa. Approximate shipping weights range from 1/8" to 1/4 lb.
Special Features
Table 21.55:
Description Conduit Seal Only Conduit seal fits in conduit entrance and excludes liquids Adapters Switch with adapter plate permitting substitution of any Type C switch with standard box for any Type T switch with Style B baseplate Adapter plate kit only (plate plus mounting screws) for above Adapter plate to allow direct substitution of Type C plunger switches for Type B plug-in plunger switches use only if there is a problem in lining up cam tracks Adapter plate kit permitting direct substitution of any Type C lever arm switch with standard box for ANY Type AW lever arm switch Metric conduit-connection adaptermale 1/2" NPT on one end, female 20 mm on the other end b c Dimensions: 0.22" x 2.94" x 1.54" Dimensions: 0.22" x 2.07" x 1.54" Standard Box Compact Box Form Y147 Class 9007 Type BT1 Class 9007 Type CT10 b Type CT13 c Class 9007 Type CT11 Class 9007 Type CT12 28.70 additional 18.90 18.90 18.90 35.60 52.00 5 hole seal 9 hole seal
9007LA19
2.06 52
0.13 3.3
0.58 15 1.24 31
2.35 60
(1) (2)
4.02 102
5.5 12.7
1.19 30
0.13 3.3
(3)
0.52 13
1.17 30 1.55 39
0.64 16 1.79 45
1.00 25
0.41 10
0.41 10
Dual dimensions:
1. 2. 3.
in. mm
2 x 0.20/5 x 0.22/6 HLS. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP. 1/2 14 NPT.
CP1
Discount Schedule
21-25
21
LIMIT SWITCHES
21
LIMIT SWITCHES
Table 21.56:
Special Features
Special Features (Do not apply to Type CR unless noted)Not Field Installable, Except Where Noted
Form Add S9 as a suffix to the catalog number Cat. No. 9007S9 $ Price Addition
Optional Shaft Equipped With 9007T / 9007FT Hub: Any lever arm Type C, CF or CR switch can be furnished with an optional shaft and hub combination which will accept the lever arms normally used with Type T and FT limit (position) switches. To order, add S9 as suffix to the device type number. For example, to order a 9007 C54B2 with this modification, order as a 9007 C54B2-S9. For details about the switches and lever arms that can be furnished with this modification, see catalog 9007CT0501. Hub Only: Can be field installed on any Type C lever type switch. LED Pilot Light, 24-120 Volts AC or DC on Plug-In Type Switch (Type C52, C54, C62, C64, C66, or C68): Addition of LED pilot light in parallel with N.O. contact (light normally on) Form P10 Form P5 Thru P9 L2 L1 Addition of LED pilot light in parallel with N.C. contact (light normally off) L2 Light Normally On L1 *Customer Addition of two LED pilot lights, one in parallel with N.O. contact (light normally on), Installed one in parallel with N.C. contact (light normally off) CR1 Jumper CR1 Addition of two LED pilot lights in parallel with N.O. contacts (lights normally on) B CR2 (Types C62, C64, C66 or C68 only) CR2 A Addition of two LED pilot lights in parallel with N.C. contacts (lights normally off) (Types C62, C64, C66, or C68 only) *Only one of the jumpers may be used Light Normally Off Pilot Light is ON when load is energized Addition of one isolated LED pilot light (light on when load is energized) (Type C54 only. Not available with Y1901.) Plug-in limit (position) switch furnished with pre-wired mini 5 pin male receptacle. For use with Pre-Wired Receptacle Brad Harrison female portable plug No. 41306, 41307, or 41308 (or equal). (Not available with P10 or for hazardous locations.) Single Pole Same as Y1901 but with different wire color coding Tamperproof ScrewsComplete Switch Only Same as Y1901 but with tamperproof screws on head and body Other versions with different wiring diagrams per automotive requirements are available. Contact your local Square D field office.
Wiring Diagrams Form Y190__ Forms Y1901 and Y1903 Form Y1905 WhiteOrange3 1 4 -Black 2 -Red
14.30
14.30
OrangeWhite-
3 1
4 2
-Red -Black
Green-
Green-
Potted Limit (Position) Switch Or Plug-In Receptacle Only: With Individual Wires Single pole plug-in limit (position) switch or receptacle pre-wired with five #16 wires 5 ft long and wire entry completely sealed with Epoxy Resin Two pole plug-in limit (position) switch or receptacle pre-wired with nine #16 wires 5 ft long and wire entry completely sealed with Epoxy Resin With STOWA Cord Single pole plug-in limit (position) switch or receptacle pre-wired with five conductor #16 STOWA cord 8 ft long and wire entry completely sealed with Epoxy Resin Y1855: Same as Y1851 but with different wire color coding Two pole plug-in limit (position) switch or receptacle pre-wired with nine conductor #16 STOWA cord 8 ft long and wire entry completely sealed with Epoxy Resin Y1856: Same as Y1852 but with different wire color coding Tamperproof ScrewsComplete Switch Only With Individual Wires Same as Y1841 but with tamperproof screws on head and body Same as Y1842 but with tamperproof screws on head and body With STOWA Cord Same as Y1851 but with tamperproof screws on head and body Same as Y1852 but with tamperproof screws on head and body Same as Y1855 but with tamperproof screws on head and body Same as Y1856 but with tamperproof screws on head and body Other versions with different wiring diagrams for automotive requirements are available.
Forms Y1851 and Y1853 RedWhite3 1 4 2
Forms Y1855 and Y1857 -Brown -Yellow -Blue -Pink White- 3 Orange- 1 Green4 2
-Orange -Black
-Black -Red
YellowBrownRedOrange-
4 3 2 1
8 7 6 5
Green-
Green-
Green-
Low TemperatureLever Types Only: Limit (Position) switch will operate in an ambient temperature range of -40 to +185 F (standard limit switch ambient temperature range is -20 to +185 F). Minimum temperature is based on the absence of freezing moisture or water. Viton Fluorocarbon Gaskets And Seals Substitute Viton fluorocarbon gaskets and seals on: Lever arm type, standard box (shaft seals on lever arm types are Viton fluorocarbon as standard) Lever arm type, compact box (shaft seals on lever arm types are Viton fluorocarbon as standard) Plunger type, standard box Plunger type, compact box Substitute Viton fluorocarbon boot only on plunger type switches Note: Viton fluorocarbon has been shown to resist sunlight aging problems. Direct Acting Contacts Substitution of direct acting contact unit for snap switch of single pole switch: One pole, normally closed, slow make-slow break, direct acting contact mechanism substituted for standard snap switch on Types C52, C54, CF53 and CR53 devices. This mechanism was designed for use in emergency overtravel applications. The movable contact of this basic switch unit is acted upon directly by the actuating mechanism of the limit switch and is not dependent upon the force exerted by a snap switch blade or spring to open the circuit. Because these contacts are slow make-slow break, they are best suited for applications where they are not actuated during normal operation, but only if abnormal overtravel is encountered. Note: Direct acting contacts described above are supplied on the 9007 CLS1 hoist overtravel switch as standard.
Y128
28.70
21-26
CP1
Discount Schedule
XCKJ precision switches have direct opening contact to meet most international standards. Table 21.57: Specifications
-13 to +158 F (-25 to +70 C); optional -40 to +248 F (-40 to +120 C). The minimum temperatures listed are based on the absence of freezing moisture or water. NEMA 1,2,3,4,12; IEC Type IP66 25 G (10-500 Hz), conforming to IEC 68-2-6 50 G, conforming to IEC 68-2-27 0.0004" (0.01mm) 1/2" NPT standard 10 A, conforming to UL 508, CSA C22-2 No.14, IEC 337-1, NFC 63-140, VDE 0660-200 Non-plug-in: 300 Vac (A300) and DC (Q300) Plug-in: 600 Vac (A600) and DC (Q600) Non plug-in: 25 m Plug-in: 45 m 2 x 16 AWG (1.5 mm2) per terminal1 x #16 AWG for 2 SPDT (2 N.O. - 2 N.C.) 10 A fuse type SC; Form I Class J or equivalent. Outside US use type gl or N.
Rated Power (Conforms to IEC 947-5-1, duty categories AC15 and DC13) Temperature range Enclosure rating Vibration resistance Shock resistance Repeatability (max.) Cable entry
XCKJ10511
Contact Characteristics Rated thermal current Rated insulation voltage Contact resistance (max) Cable (max.) Short circuit protection
Table 21.58:
XCKJ10541
Lever operated
23 21-22 13-14 21-22 13-14 0 11 90 58(P)
DELRIN roller lever adjustable in 5 or 45 increments (reversible mountings) 33.3 in-oz SPDT (N.O. + N.C.) Ya 33.3 in-oz 2 SPDT (2 N.O. + 2 N.C.) N Adjustable lengthDELRIN roller lever adjustable in 5 or 90 increments 33.3 in-oz SPDT (N.O. + N.C.) N 33.3 in-oz 2 SPDT (2 N.O. + 2 N.C.) N Adjustable length1/8" diameter steel rod adjustable in 5 or 45 increments 33.3 in-oz SPDT (N.O. + N.C.) N Adjustable length1/4" plastic rod adjustable in 5 or 45 increments 33.3 in-oz SPDT (N.O. + N.C.) N
XCKJ161
Neutral Position One SPDT contact switch per direction. Past 20 CW, contact 1 (11-12 / 13-14) switches. Past 20 CCW, contact 2 (21-22 / 23-24) switches. Levers not included.
20 11-12 13-14 11-12 13-14 0 11 20 90
26.6 in-oz
23-22 23-24 21-22 23-24
ZCKJ404
214.00
90"
11
Plunger Operater
.08 21-22 13-14 21-22 13-14 0 .035 .24 .185(P)
Rod plunger 48 oz
SPDT
(N.O. + N.C.)
Ya
XCKJ161
154.00
XCKJ110511
SPDT
(N.O. + N.C.)
Ya
XCKJ167
166.00
DELRIN roller lever adjustable in 5 or 45 increments (reversible mountings) 33.3 in-oz SPDT (N.O. + N.C.) N Adjustable length DELRIN roller lever adjustable in 5 or 90 increments 33.3 in-oz SPDT (N.O. + N.C.) N
XCKJ110511
168.00
XCKJ110541
168.00
Neutral Position One SPDT contact switch per direction. Past 20 CW, contact 1 (11-12 / 13-14) switches. Past 20 CCW, contact 2 (21-22 / 23-24) switches. Levers not included.
XCKJ1167
26.6 in-oz
2 SPDT
(2 N.O. + 2 N.C.)
ZCKJ4104
214.00
90"
11
Plunger Operated
.08" 11-12 13-14 11-12 13-14 035"
SPDT
(N.O. + N.C.)
XCKJ1161
154.00
SPDT
(N.O. + N.C.)
XCKJ1167
166.00
XCKJ167
24"
Direct opening contacts meet IEC 947-5-1 requirements for positive opening contacts.
Discount Schedule
21-27
21
LIMIT SWITCHES
6.5
76.5
60
41
(1) 33.5 44 = 30 40 =
File CCN
E39281 NKCR
File Class
LR44087 3211-03
Acceptable Wire Sizes: 1424 AWG Recommended Terminal Clamp Torque: 13 lb-in
21-28
63
21
LIMIT SWITCHES ZCKJ1 Non-plug-in ZCKJ11 Plug-in
Table 21.59:
1 Step 1 Step 1 Step 2 Step 1 Step 1 Step 1 Step 1 Step Neutral Position
Non-plug-in
Direct Opening SPDT SPDT 2 SPDT 2 SPDT SPDT 2 SPDT SPDT 2 SPDT 2 SPDT (N.O. + N.C.) (isolated N.O. + N.C.) (2 N.O. + 2 N.C.) (2 N.O. + 2 N.C.) (N.O. + N.C.) (2 N.O. + 2 N.C.) (N.O. + N.C.) (N.O. + N.C.) (2 N.O. + 2 N.C.) Snap action Slow break-before-make Snap action Snap action Snap action Snap action Snap action Snap action Snap action Ya Ya N N Ya N Ya N N Catalog Number ZCKJ1 ZCKJ5 ZCKJ2 ZCKJ4 ZCKJ18 ZCKJ28 ZCKJ15 ZCKJ25 ZCKJ4045 $ Price 94.00 112.00 124.00 136.00 140.00 146.00 120.00 124.00 240.00
Table 21.60:
1 Step 1 Step 2 Step 1 Step 1 Step Neutral Position
Plug-in
Direct Opening SPDT 2 SPDT 2 SPDT SPDT 2 SPDT 2 SPDT (N.O. + N.C.) (2 N.O. + 2 N.C.) (2 N.O. + 2 N.C.) (N.O. + N.C.) (2 N.O. + 2 N.C.) (2 N.O. + 2 N.C.) Snap action Snap action Snap action Snap action Snap action Snap action N N N N N N Catalog Number ZCKJ11 ZCKJ21 ZCKJ41 ZCKJ115 ZCKJ215 ZCKJ41045 $ Price 94.00 124.00 136.00 120.00 152.00 240.00
Table 21.61:
Wiring Options
Catalog Number Pins 5 pins 9 pins Suffix 547 947 $ Price Adder 136.00 204.00 ZCKJ1/J11/J5 ZCKJ2/J4/J21/J41
Table 21.62:
Description
Matching plug and cable assemblies for the mini style receptacle options may be ordered as follows:
947
Direct opening contacts meet IEC 947-5-1 requirements for positive opening contacts when using
62 57 5 41
Discount Schedule
Table 21.63:
Lever-Operated Heads
1 Step ZCKJ1a, J11, J2, J21
23 58(P) 21-22 13-14 0 0 11 90 33 90 21-22 13-14 21-22 13-14
1 Step ZCKJ5a
23 40(P)
Operating Force/Torque
Catalog Number
$ Price
23
33 in-oz, 0.25 N
ZCKE05
59.00
42
ZCKE05 Programming
CW and CCW
65 21-22 13-14 0 90
CW
CW and CCW
CCW
Maintained operation
65 21-22 13-14 90 0
33 in-oz, 0.25 N
ZCKE09
79.00
Note: Neutral position head ZCKE04 is not available separately. Order the head and body subassemblies from page 21-27.
Table 21.64:
Plunger-Operated Heads
1 Step ZCKJ1a, J11, J2, J21
.08 .185(P) 11-12 13-14 11-12 13-14 0 .035 .24 0 .035" .24" 21-22 13-14 21-22 13-14
1 Step ZCKJ5a
.08 .135(P)
Operating Force/Torque
Catalog Number
$ Price
.125
.24"
48 oz 18 N
ZCKE61
59.00
48 oz 18 N 48 oz 18 N
.114 21-22 13-14 0 .182 .193(P)
ZCKE66
72.00
Steel roller plunger One-way DELRIN roller based on actuation by 30 cam One way steel roller based on actuation by 30 cam
.114 21-22 13-14 21-22 13-14 0 .05" .261(P)
ZCKE67
72.00
48 oz 18 N 48 oz 18 N
ZCKE21
66.00
ZCKE23
66.00
.06"
.114 (P)
.217
48 oz 18 N
ZCKE63
72.00
Side steel roller plunger-horizontal based on actuation by 30 cam Side steel roller plunger-vertical based on actuation by 30 cam a Direct opening
.6
.107(P)
48 oz 18 N 48 oz 18 N
ZCKE64
85.00
.105
.035
ZCKE65
85.00
when used with any head on this page except ZCKE09 (maintained operation).
Discount Schedule
21-29
21
LIMIT SWITCHES
21
LIMIT SWITCHES Non-Plug in Style Contact Block XE2SP2151 ZCKY11/13/14 ZCKY43/41 ZCKY51/52/53/59 ZCKY61 ZCKY71 ZCKY81 ZCKY91
Table 21.65:
Omnidirectional Heads
1 Step ZCKJ1, J11,J2,J21
20 21-22 13-14 21-22 13-14 0 10 21-22 13-14 0 45
Contact Operation with Switch Bodies: Cat whisker-steela Wobble coil springsa a
1 Step ZCKJ5
20
$ Price
59.00 59.00
Table 21.66:
Description
Lever operated
85.00 106.00 85.00 98.00 98.00 92.00 92.00 98.00 112.00 74.00 85.00 85.00
Plunger operated
Omnidirectional b
The minimum temperatures listed are based on the absence of freezing moisture or water.
Table 21.67:
Replacement Parts
Direct Opening Y N N Y Y N N N N Catalog Number XE2SP2151 XESP2021 XESP2031 XE2NP2151 XE2SP2158 XESP2028 ZCKJ01 ZCKJ02 ZCKJ04 ZCKJ019 ZCKJ029 ZCKJ029 $ Price 47.60 59.00 94.00 54.00 79.00 59.00 72.00 124.00 114.00 72.00 41.40 41.40
Description (see page 21-28 for contact description) Contact block for ZCKJ1 Contact block for ZCKJ2 Contact block for ZCKJ4 Contact block for ZCKJ5 Contact block for ZCKJ18 (gold flashed) Contact block for ZCKJ28 (gold flashed) Plug-in module for ZCKJ11 (includes contact block) Plug-in module for ZCKJ21 (includes contact block) Plug-in module for ZCKJ41 (includes contact block) Base receptacle for ZCKJ11 Base receptacle for ZCKJ21 Base receptacle for ZCKJ41
Table 21.68:
Description
Lever Arms
Adjustment Increments Catalog Number $ Price
Adjustable or Flexible Operators c Adjustable DELRIN roller, 0.74 in. diameter, 0.2 in. wide, 3 in. long (max.) Adjustable steel roller, 0.74 in. diameter, 0.2 in. wide, 3 in. long (max.) Adjustable rod-square, steel, 1/8 in. side, 5.4 in. long (max.) Adjustable rod-round, fiberglass, 1/8 in. diameter, 5.4 in. long (max.) Adjustable rod-round, steel, 1/8 in. diameter, 5.4 in. long (max.) Adjustable rod-round, plastic, 1/4 in. diameter, 8.4 in. long (max.) Coil spring lever Spring rod lever Reverse Mounting DELRIN roller 0.9 in. diameter, 0.2 in. wide, 1.6 in. long Steel roller 0.9 in. diameter, 0.2 in. wide, 1.6 in. long Ball bearing roller 0.9' diameter, 0.2 in. wide, 1.6 in. long Fork, 2 track, DELRIN roller, 0.9 in.diameter, 0.2 in. wide for ZCK-E09 Fork, 1 track, DELRIN roller, 0.9 in. diameter, 0.2 in. wide for ZCK-E09 c d 5 or 45 d 5 or 45 d 5 or 45 d 5 or 45 d 5 or 45 d ZCKY11 ZCKY13 ZCKY14 ZCKY61 ZCKY71 15.40 15.40 41.40 28.40 28.40 5 or 90 5 or 90 5 or 45 5 or 45 5 or 45 5 or 45 5 or 90 5 or 90 ZCKY41 ZCKY43 ZCKY51 ZCKY52 ZCKY53 ZCKY59 ZCKY81 ZCKY91 15.40 15.40 15.40 15.40 15.40 15.40 15.40 15.40
Adjustable and flexible operators do not guarantee positive opening operation. Reverse mounting: The higher increment (45) is a direct (positive) opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the direct (positive) contact (N.C.) even if the lever is loosely mounted.
21-30
Discount Schedule
9007T, 9007FT
Class 9007 / Refer to Catalog 9006CT0101
Table 21.69:
Complete with Base Plate, Without Lever Arm (bold type numbers indicate the most commonly used switches)
No. 1 Single-Pole Double-Throw Spring-Return CW Only No. 2 Single-Pole Double-Throw Spring-Return CW Only No. 3d Single-Pole Double-Throw Maintained Contact Universal Type No. 4 Single-Pole Double-Throw Spring-Return Neutral Position No. 5 Single-Pole Double-Throw Spring-Return CCW Only No. 6 Single-Pole Double-Throw Spring-Return CCW Only No. 7d Single-Pole Double-Throw Maintained
Spring return of arm to initial position, contact position maintained until operated in reverse direction CCW CW
A B A B
Initial Position
A B
CW A B
CCW
A B
CW
A B
Intermediate Pos. CW A B
CCW
A B
Final Pos. CW A B
CW
A B
Base Plate A B Surface Mounting C D Pre-travel Total-travel Nominal Operating Differential Data Oper. Torque Repeat Accuracy b To convert sequences, remove base plate, pos. plate and latches. Reassemble pos. plate and latches as shown.
Type
$ Price
Type
$ Price
TUA2 428.00 TUB2 428.00 TUC2 428.00 TUD2 428.00 Int. Pos. 9, Final 16 88 5 12 lb-in 0.004 in.
A
TUA6 428.00 TUB6 428.00 TUC6 428.00 TUD6 428.00 Int. Pos. 9, Final 16 88 5 12 lb-in 0.004 in.
Universal Type No. 10 Single-Pole Double-Throw Spring-Return Slow Make Slow Break
No. 3 Single-Pole Double-Throw Spring-Return CW & CCW Slow Make Slow Break
Initial Position
A B
CCW
A B
Initial Position
A B
Initial Position
A B
Initial Position
A B
CCW
CW
A B
CCW
CW
A B
CW
A B
CW CCW
A B A B
CCW & CW
A B
CW & CCW
A B
Base Plate A B Surface Mounting C D Pre-travel Total-travel Nominal Operating Differential Data Oper. Torque Repeat Accuracy b To convert sequences, remove base plate, pos. plate and latches. Reassemble pos. plate and latches as shown.
Type
$ Price
TSA2 428.00 TSB2 428.00 TSC2 428.00 TSD2 428.00 Int. Pos. 9, Final 16 89 Int. Pos. 5.5, Final 7.5 10 lb-in 0.004 in.
A
Pre-travel listed may vary up to 5 additional for universal switches or up to 2 additional for standard switches due to free travel of lever arm at initial position. Linear travel of cam on 1-1/2 in. lever arm. Remove the spring from the positioning plate. Sequence 3, 7, and 8 devices are available but are not recommended where high speed cams or lever arm snap-back is present. The application should be checked and No. 12 sequence substituted where possible. Note: To obtain a Type FT Foundry Switch, change the T at the beginning of the equivalent type number to FT and add $169 to the list price. (Ex. FTUB1, $597.00) Lever arms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 21-32
CP1
Discount Schedule
21-31
21
LIMIT SWITCHES
9007T, 9007FT
Class 9007 / Refer to Catalog 9006CT0101
www.schneider-electric.us
21
LIMIT SWITCHES 9007TUB4 9007FTUB4
Lever Arms for Types T and FT Limit Switches or Type C with S9 Hub
Description Type Roller Width 1/4 1/2 1/4 1/2 None Roller Dia. (in.) 3/4 B1 B12 B7 B22 Without Roller B21 B19 R18 C1 D1 E4 F4 J1 K1 N1 X1 Y1 Z1 1 B2 B13 B8 B23 R19 C2 D2 E5 F5 J2 K2 N2 X2 Y2 Z2 Y3 B27 R16 R17 B16 G10 D4 R21 R22 1-3/8 B3 B14 B9 B24 R20 C3 D3 E6 F6 $ Price 38.10 38.10 59.00 59.00 59.00 45.00 59.00 39.60 59.00 38.10 38.10 138.00 138.00 138.00 138.00 138.00 138.00 138.00 59.00 81.00 81.00 143.00 23.90 187.00 153.00 153.00
Type of Arm
Roller Position Front or Back Front or Back Front or Back Front or Back None
Straight
Offset 1-7/8 120 Forked 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2-1/2 Adj. Adj. 1-1/2 3-1/2 1-1/2 8-7/16
90 Forked Cable Operated Rod Ball Bearing Weld-On 1-Way Roller Conveyor Side Guide
Front or Back 1/4 Does not include a lever arm clamp or rod. Lever arm clamp is requireduse 9007 R16 or R17, 1/4 plus a customer-supplied rod. Inside Offset 1/4 Outside Offset 1/4 Outside Offset 1/4 Inside Offset 1/4 Rollers on Same Side 1/4 LH Roller on Opposite Side 1/4 RH Roller on Opposite Side 1/4 Rollers on Same Side 1/4 RH Roller on Opposite Side 1/4 LH Roller on Opposite Side 1/4 None None With eyebolt (1/4 in. I.D.) instead of roller None Clamp for 3/16 in. Rod (rod not included) None Clamp for 1/4 in. Key Stock (key stock not included) None Center 9/32 None None Outside Offset 1/4 1-1/2 in. dia. 3-3/4 in. DELRIN roller. For use with Type T and FT only. 7/8 in. dia. 3-3/4 in. DELRIN roller. For use with Type T, FT, or C with S9.
Table 21.71:
Style
Part Number
A Nonea 2934D32G1 B End 2934D14G1 C Side 2934D33G1 D End 2934D34G1 a No mounting holes in base plate. Side mounting holes in switch case must be used. For all Type T and FT: Acceptable Wire Sizes: 1418 AWG Recommended Terminal Clamp Torque: 1316 lb-in
2.06 52
.75 19 .56 14
.21 5
2.25 57
.53 13 1.12 28
1.75 44
.53 13
2.62 66
4.31 109
2.25 57
Style B
Style C
Style D
21-32
CP1
Discount Schedule
L100/300
Refer to Catalog 9006CT0101
R.B.Denison Lox-Switch L
Table 21.72: General Specifications
0 to +200 F (-17 to +93 C) standard. For high and low temperature options, see Table 21.79 on page 21-34. Minimum temperatures are based on the absence of freezing moisture or water. NEMA 1, 4, and 13; IP 65, 66 30G max. (1055Hz) .03 1/2" NPT standard Double Circuit, 3/4" NPT Triple Circuit Contact characteristics Rated thermal current 20 A
Rated insulation voltage 600 Vac and Vdc Wire (max.) 1 x 12 AWG or 2 x 14 AWG per screw terminal
Table 21.73:
Contact Rating Designation
7200 138
720 138
L300WS2M1
Table 21.74: Type L Selection Other selections are available. Refer to catalog 9006CT0101.
Mounting Plates, L100 and L300 Models Description Contact Diagram Operating Torque 190 oz-in (1.34 Nm)
1 2 3 4 1 2 3 4
Cat. No. L100WS2M1 L300WS2M1 L100WS2M2 L300WS2M2 L100WS2M3 L300WS2M3 L100WDR2M4 L300WDR2M4 L100WNS2M26 L300WNS2M26 L100WNSL2M29 L300WNSL2M29
$ Price 298.00 328.00 298.00 328.00 298.00 328.00 328.00 354.00 298.00 324.00 332.00 358.00
Style 1
1 2
3 4
1 2
3 4
Style 2
1 2
3 4
1 2
3 4
5 6
3 4
5 6
3 4
1 2
3 4
1 2
3 4
1 2
3 4
Style 3
Neutral position a N.O.-CW, N.O.-CCW Maintained in CW only
1 2 3 4 1 2 3 4 1 2 3 4
5 6
3 4
5 6
3 4
5 6
3 4
L525WDR2M56
358.00
Style 4
1 2
5 6
1 2
5 6
1 2
5 6
L525WDL2M57
358.00
1 2
5 6
1 2
5 6
1 2
5 6
L525WDL2M58
358.00
5 6
3 4
5 6
3 4
5 6
3 4
L525WDR2M59
358.00
1 2
3 4
1 2
3 4
1 2
3 4
L100WS0S2M60
358.00
The lever must not be allowed to snap freely from any overtravel position.
Discount Schedule
21-33
21
(M=Make, B=Break)
LIMIT SWITCHES
L100/300
Refer to Catalog 9006CT0101
www.schneider-electric.us
21
LIMIT SWITCHES
L
.97 2.45
Use the table below to interpret the catalog numbers of the L100/L300 switches. Do not generate new catalog numbers from the table. If the required contact sequence is not listed, contact your local field office. The only modifications to the existing catalog numbers are:
Mounting PlatesStyle 1, 2, 3 or 4 Front CoversMetal, transparent plastic, or transparent plastic with a neon light. Special FeaturesSelect from catalog 90006CT0101 and add to the type number.
Style L 1 Housing 0 0 W Function S Mounting Plate 2 Front Cover P F Contact Arrangement
.50 12.
1 2 3 4 M PF GF
2.230
5.730 3.00
Rolling Pin
Table 21.75:
Steel Roller Lever Arms (0.25 in. wide, 0.75 in. dia.)
Length (L) Lever Number AA AH AO AK AB AM AR $ Price 19.20 24.60 24.60 24.60 24.60 35.40 41.00
Table 21.76:
Description
4.06 103
Adjustable Roller
1 in. diameter roller 1-1/4 in. diameter roller 1-1/2 in. diameter roller Nylon roller Ball bearing roller (3/4 in. diameter) Stainless steel roller pin nylon roller Ex: AB1; ABR
Table 21.77: Rolling Pin For use with 2 step switches for conveyor or belt applications
Length (L) In. (mm) 2.25 (75.1) 2.25 (75.1) (Teflon for high temperature applications) 3 (50.8) Lever Number AL1650 AL16501 AL1802 $ Price 82.00 152.00 132.00
Table 21.78: Roller, Adjustable from 2 to 4 in. (0.25 in. wide, 0.75 in. diameter)
Length (L) In. (mm) Adjustable 2 to 4 (50.8 to 101.6) Lever Number $ Price AL2820 82.00
Table 21.79:
Ministyle male receptacle
Housing options a
Examples L100WS2M1 changes to GL100WS2M1 L100WS2M1 changes to HL100WS2M1 L100WS2M1 changes to TL100WS2M1 L100WS2M1 changes to L526WS2M1 L300WS2M1 changes to L326WS2M1 L100WS2M1 changes to L522WS2M1 L300WS2M1 changes to L322WS2M1 Prefix Adder or Modifier $ Price Adder G H T 526/326 522/322 95.00 14.80 82.00 38.00
Description 3/4" conduit opening Available on 2 circuit switches. Standard on 3 circuit switches. High temperature 0 to +350 F d Metal front cover only Low temperature -20 to +200 F d High shock. Available only on operating sequences 1, 2, 4, 5, 7-11, 13, 14. Gold contacts
Table 21.80:
Description
Wiring
Examples L100WS2M1 changes to PL100WS2M1 L100WS2M1 changes to APL100WS2M1 L100WS2M1 changes to BL100WS2M1 L100WS2M1 changes to L100WS2M1P L100WS2M1 changes to L100WS2M1P12 L100WS2M1 changes to L100WS2M1P18 Prefix Adder or Modifier $ Price Adder P AP B B P P12 P18 84.00 152.00 132.00 132.00 84.00 95.00 106.00
Straight male receptacle 4 pin b Factory prewired 90 Angle male receptacle 4 pin b Factory prewiredfacing right 8 A max., 5 pin (double circuit) Ministyle male receptacle c 7 A max., 7 pin (triple circuit) 5 wires, 6 ft long Potted and prewired 5 wires, 12 ft long 5 wires 18 ft long
Table 21.81:
Description
Accessories
Catalog Number $ Price
Table 21.82:
Description Standard metal 1010004 1010006 10100010 172.00 204.00 268.00
Front covers
Designator M PF $ Price 6.40 6.40
Sealed female plug and cable for P and AP receptacles 4 pins, 16 AWG STO cable, 60 C 4 ft 6 ft 10 ft
Transparent plastic cover with metal frame Transparent plastic cover with metal frame and Neon indicator light (not connected)
GF
44.40
3 ft cable BH2053 122.00 5 pins, 16 AWG STO cable, 105 C 6 ft cable BH2056 166.00 Ex. L100WS2M1 changes to L100WS2PF1 12 ft cable BH20512 264.00 a Other options availablecontact your Square D/TE representative for details. b Receptacle is a 4 pin male APL/PL-SWTS, Cannon part # MS3102E20-4P-F79 or equal. c Ministyle male receptacles are: 5-pin, Brad Harrison #41310 (or equal); 7-pin, Brad Harrison #42805 (or equal) d The minimum temperatures listed are based on the absence of freezing moisture or water.
21-34
Discount Schedule
Table of Contents
Section 22
Pressure, Vacuum, and Float Switches
ElectronicIndustrial
New!
Pressure Sensors
XMLG
22-4
XMLF
22-6
ElectromechanicalIndustrial
XMLG Pressure Sensor p. 22-4 XMLF Electronic Pressure Switch p. 22-6
New!
Pressure Switches
22-8
9012G General Industrial 9012G Machine Tool 9012G Dual Stage and Differential Vacuum Switches 9016GAW, GAR
ElectromechanicalCommercial
9012G Industrial Pressure Switch p. 22-11 9012G Machine Tool Pressure Switch p. 22-12
22-17 22-18 22-19 22-20 22-21 22-22 22-22 22-23 22-24 22-24
Float Switches
Renewal Parts
Renewal Part Kits
9013F Water Pump Switch p. 22-19 9013G Air Compressor Switch p. 22-20
22-26
22-1
22
Selection Guide
Class 9012 / Refer to Catalog 9012CT9701 or 9014CT0201
www.schneider-electric.us
Electromechanical Control
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
Fluids Controlled
Air, water, hydraulic oils, corrosive fluids Pressure/vacuum switches and transmitters Pressure/vacuum switches and transmitters Configurable units with digital display Analog output 420 mA Regulation between 2 trip points (adjustable differential) -14.5 to 8700 psi Analog, 420 mA Digital, PNP or NPN, 200 mA, Relay output 2 A M12 connector, Snap-C compatible SAE 7/8-16 UN2A G 1/4" BSP internal, 1/4" NPT internal SAE 7/16"-20 UNF female Pressure/vacuum switches Detection of single trip point (non-adjustable differential) Regulation between 2 trip points (adjustable differential) -14.5 to 7250 psi Snap action contacts SPDT or DPDT 10 A continuous Cable entry for No. 13 (DIN PG13.5) Cable Gland G 1/4" BSP internal, 1/4" NPT internal 1/4"-18 NPT external Pressure switches Detection of single trip point (non-adjustable differential) Regulation between 2 trip points (adjustable differential) 2-stage 0.2 to 9000psi Snap action contacts SPDT or DPDT 10 A continuous 1/2" -14 NPT Cable entry 20 mm 1/4" - 18 NPTF internal 7/16"-20 UNF-2B internal G 1/4" BSP internal G 1/4"-19 BSP internal Hydraulic oils, air, fresh water, sea water, corrosive fluids from -26 to +120 C (-15 to +250 F) depending on model Vacuum switches Regulation between 2 trip points (adjustable differential) 0 to 29 inches of Hg Snap action contacts SPDT 10 A continuous DPST horsepower rated 1/2" -14 NPT Cable entry 20 mm G 1/4" BSP internal, 1/4" NPT internal 1/4" - 18 NPT external
-14.5 to 5800 psi Analog, 420 mA or 010 V Digital, PNP or NPN normally closed (NC) output M12 connector or Integrated quick connection G 1/4" BSP internal, 1/4" NPT internal SAE 7/16"-20 UNF female
Electrical Connection
Fluid Connection
Fluid Characteristics
Hydraulic oils, air, fresh water, sea water, corrosive fluids from -15 to +125 C (5 to +257 F)
Hydraulic oils, air, fresh water, sea water (0 to +160 C), Hydraulic oils, air, fresh water, depending on model sea water, corrosive fluids from Steam, corrosive fluids, viscous 15 to +80 C (5 to +176 F) products (0 to +160 C), depending on model IP67 conforming to IEC/EN 60529, NEMA 4/6/12/13 1.81 x 4.45 x 2.28 in. (46 x 113 x 58 mm) CE, IEC/EN 60947-1, IEC/EN 60947-5-1, EN 50081, EN 50082, EN 61000-6-2, EN 61000-4-2/3/4/5/6/8/11 UL Listed, CSA Certified Screw terminal models: IP 66 conforming to IEC 529 4.45 x 1.38 x 2.95 in. (113 x 35 x 75 mm) NEMA 4: 3.50 x 3.60 x 2.63 in. (89 x 91 x 67 mm) CE, IEC/EN 60947-5-1, VDE 0660-200, UL 508, CSA C22-2 No. 14
Hydraulic oils, air, fresh water, sea water, from -26 to +120 C (-15 to +250 F) depending on model
IP66, IP67 conforming to IEC/EN 60529, NEMA 4 dia. 90 x 2.762.95 (dia. 22.8 x 70.1mm)
NEMA 1: 2.06 x 5.03 x 2.75 in. (52 x 128 x 70 mm) Control circuit: same as 9012G NEMA 4: 3.50 x 3.60 x 2.63 in. Power circuit: same as 9013G (89 x 91 x 67 mm)
Conforming to Standards
CE, IEC/EN 60947-1, IEC/EN 60947-5-1, EN 50081-1, EN 50082-2, EN 61000-6-2 UL Listed, CSA Certified
Certifications
UL B300 - R300 Listed. UL Listed, CSA B300 - R300, (BV, GL, RINA, LROS pending) CSA Certified 9012GA, 9012GC,9012GG, 9012GH,9012GK, 9012GM, 9012GR, 9012GS, 9012GT, 9012GN,9012GP, 9012GQ
Catalog Number
XMLG
XMLF
9016GA, 9016GV
22-2
Selection Guide
Class 9013, 9036, 9037, 9038 / Refer to Catalog 9013CT9701 or 9034CT9701
Electromechanical Float
Application
Electromechanical Power
9013F Power circuits Fresh water, air Pressure switches Detection of single trip point (non-adjustable differential) Regulation between 2 trip points (adjustable differential) 6 to 200 psi
Fresh or sea water, hydraulic oils; suitable for corrosive fluids except for cast iron bushing (shown above) Pressure switches Regulation between 2 trip points (adjustable differential) 10 to 250 psi
2-pole, snap action contacts HP rated 2 1/2" NPT conduit entries Open tank
2-pole, snap action contacts HP rated 2 1/2" NPT conduit entries Closed tank
2 sets of 2-pole, snap action contacts HP rated 4 1/2" NPT conduit entries Open tank (9038A) Closed tank (9038C, D)
2-pole, snap action contacts 2-pole, snap action contacts 2-pole, snap action contacts HP rated HP rated HP rated 2 1/2" NPT conduit entries 1/4" NPSF internal, 1/4" NPT external, plus other options Fresh water, air NEMA Type 1 (NEMA Type 3R in the vertical position only) IP20 3.76 x 2.8 x 2.78 in. (95.5 x 71.12 x 70.6mm) NEMA A600 UL508 UL Listed, CSA Certified 9013FS, 9013FR, 9013FH, 9013FT, 9013FY NEMA Type 1, 3R, 7, 9 IP20 2 1/2" NPT conduit entries 1/4" NPSF internal, 1/4" NPT external 2 1/2" NPT conduit entries Open tank
Electrical Connection
Enclosure Rating
NEMA Type 1, 4 , 7, 9
NEMA Type 1, 4 , 7, 9
NEMA Type 1, 4 , 7, 9
NEMA Type 1, 4 , 7, 9
Dimensions of Case width x height x depth in. (mm) Conforming to Standards Certifications
3.68 x 3.85 x 3.44 in. (93.47 x 97.79 x 87.37mm) NEMA A600 UL508 UL Listed, CSA Certified
See pages 22-22, 22-23 NEMA A600 UL508 UL Listed, CSA Certified 9037EG, 9037EW, 9037ER,9037HG, 9037HW, 9037HR
NEMA A600 UL508 UL Listed, CSA Certified 9038AG, 9038AW, 9038AR, 9038CG, 9038CW, 9038CR, 9038DG, 9038DW, 9038DR
Catalog Number
22-3
22
Fresh water, sea water, hydraulic oils (and corrosive fluids, depending on model) with a density 0.8
Liquid level control in Open tanks either pumping in or pumping out of tank
Liquid level control in Open tanks either pumping in or pumping out of tank
Liquid level control in Closed tanks for condensate, return heating water, fuel oil, etc.
Liquid level control in Open or Closed tanks two pumps alternate, and both pumps run in peak demand
Pressure Sensors
New!
XMLG pressure transmitters and pressure switches are characterized by their ceramic pressure measuring cell. The deformation caused by the pressure is transmitted to the resistors of a Wheatstone bridge silk-screened on the ceramic. The change in resistance is then processed by the integrated electronics, providing either a digital or analog output signal. Table 22.1:
Enclosure Rating Ambient Temperature (Operation) Media Temperature Precision (Linearity, Repeat Accuracy, Hysteresis) Repeat Accuracy (PNP/NPN output) Maximum Load Current Rated Voltage Voltage Limits Fluids Controlled Materials in Contact with Fluid
Specifications
IP66, IP67 conforming to IEC/EN 60529, NEMA 4 -15 to +85 C (+5 to +185 F) -15 to +125 C (+5 to +257 F) Transmitters: <0.3%; pressure/vacuum switches: <1% 0.1% of the meauring range Transmitters: < 20 mA; pressure/vacuum switches: <4 mA 12/24 V for transmitters and pressure/vacuum switches 24 V for transmitters and pressure/vacuum switches Hydraulic oils, air, fresh/sea water, corrosive fluids from -15 to +125 C (+5 to +257 F) Ceramic Al2O3, stainless steel type AISI 303, Viton FPM, PPS (leakage protection for P> 40 bar) < 2 ms
22
PRESSURE, VACUUM, AND FLOAT SWITCHES XMLGD M12 Connector XMLGQ Quick Connect
Table 22.2:
XML
10
bar M01 001 010 025 100 250 400 -14.5 to 0 0 to 14.5 0 to 145 0 to 362.5 0 to 1450 0 to 3625 0 to 5800
D
Electrical connection D: M12 -1 to 0 Q: Integrated 0 to 1 0 to 10 quick connect 0 to 25 0 to 100 0 to 250 0 to 400
2
Output 1: DC Analog, 420 mA, shunt calibration 2: Analog, 420 mA 3: Solid state, NPN 4: Solid state, PNP 7: Analog, 010 V (bulk packs only) 11: DC Analog, 010 V shunt calibration
1
Fluid connection 1: G 1/4 A (BSP male) 3: 1/4" NPT male 7: 7/16-20 UNF male
TQ
Bulk pack
NOTE: Use this table only to interpret the catalog number. Some combinations are not available. Table 22.3:
Range -14.5 to 0 psi 0 to 14.5 psi 0 to 87 psi 0 to 145 psi 0 to 232 psi 0 to 362.5 psi 0 to 1450 psi 0 to 2320 psi 0 to 3625 psi 0 to 5800 psi a b -1 to 0 bar 0 to 1 bar 0 to 6 bar 0 to 10 bar 0 to 16 bar 0 to 25 bar 0 to 100 bar 0 to 160 bar 0 to 250 bar 0 to 400 bar 1/4" NPT Male M12
Selection
Catalog Number ab Fluid Connector Electrical Connector Analog Output, 420 mA XMLGM01D23 XMLG001D23 XMLG006D23 XMLG010D23 XMLG016D23 XMLG025D23 XMLG100D23 XMLG160D23 XMLG250D23 XMLG400D23 Analog Output, 010 Vdc XMLGM01D73 XMLG001D73 XMLG006D73 XMLG010D73 XMLG016D73 XMLG025D73 XMLG100D73 XMLG160D73 XMLG250D73 XMLG400D73 $Price 220. 220. 220. 220. 220. 220. 220. 220. 220. 220.
For devices with a switch output or 010 Vdc analog output, contact your local Schneider Electric field office . For a bulk package (25 units), add TQ to the end of the catalog number.The minimum order quantity is 50 units (two bulk packs). When ordering, specify the individual number of units, NOT the number of bulk packs. The bulk price per unit is $150 each. Minimum order quantity for factory ordered individual items (non-stock) is 48 pieces.
NOTE: For pressure sensors, settings must be specified for each order. Table 22.4:
Output Analog, 420 mA Analog, 010 Vdc Solid State, NPN Solid State, PNP
22-4
Discount Schedule
Pressure Sensors
www.schneider-electric.us
For connectors and cables, see Table 22-09 on page 22-7. Figure 22.1: Dimensions Dimension A
XMLGD21 XMLGD23 G 1/4 A (BSAP Male) 1/4" NPT Male 7/16-20 UNF Male
XMLGD27
A
12 (0.47) 2.1 (0.08)
8 (0.31) 56 (2.20)
8 (0.31) 64 (2.52)
Table 22.5:
Connector Wiring
Pressure Transmitters M12 Integrated Quick Connection M12 Electronic Pressure Switches Integrated Quick Connection
3-wire (PNP)
3-wire (PNP)
Input
+
1 4 3
+
1 3
Input
+
1 4
Output
+
1 3
GND
2
Output
3
GND Output
Output
3-wire (010 V)
Input
3-wire (010 V)
Input
3-wire (NPN)
Input
3-wire (NPN)
Input
+
1 4 3
GND
+
1 3
GND
+
1 4 3
Output GND
+
1 3
2
Output
GND
Output Output
Discount Schedule
22-5
22
22.8 (0.90)
XMLF is a user-friendly electronic pressure switch with an easy-to-read four digit display and finger-operated adjustment buttons for scrolling up and down through the menu functions. Burst pressure is six times the nominal pressure (up to 1,800 bar or 26,100 psi). DC versions protected against reverse polarity, short circuit, and overvoltage. DC versions are double insulated Response time display: 3 levels (slow-normal-fast) Available in four versions:
Universal sensor with 1 analog output (420 mA) and 1 digital output Universal sensor with 1 analog output (110 V) and 1 digital output Dual stage sensor, 2 digital outputs, 24 Vdc (17-33 Vdc) Electronic pressure switch with relay output, 120 Vac (102132 Vac)
The XMLF electronic pressure switch can be set without any tools once hooked up to a 24 Vdc power supply. It is ergonomically designed to be easy to hold and set in your hand. The pressure connection is on the bottom of the switch and the electrical connector on the top, giving a slim, straight-through profile to the switch. It has built-in water hammer resistance. It is available in AC and DC versions that both feature a 4-digit LED display. It is programmable to display either bar or psi. It also has a programmable feature for NPNPNP and N.O. or N.C. solid state outputs. Window mode (FEN) allows the switch to operate between a selected minimum and maximum range. Outputs change state when the pressures goes outside the window setting. Table 22.6:
Enclosure Rating Ambient Temperature Media Temperature Precision (Linearity, Repeat Accuracy, Hysteresis) Repeat Accuracy (PNP/NPN output) Maximum Load Current
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
Specifications
IP67 NEMA 4, 6, 12, 13 25 to +80 C (15 to + 176 F) 15 to +80 C (+5 to + 176 F) 2% of the nominal pressure 0.5% DC: 200 mA for 1733 Vdc; AC: 2.5A AC15 C300
Table 22.7:
XMLF
Configurable
100
Rated pressure Code M01 002 010 016 025 040 070 100 160 250 400 600 psi -14.5 to 0 0 to 36.25 0 to 145 0 to 232 0 to 362.5 0 to 580 0 to 1015 0 to 1450 0 to 2320 0 to 3625 0 to 5800 0 to 8700 bar -1 to 0 0 to 2.5 0 to 10 0 to 16 0 to 25 0 to 40 0 to 70 0 to 100 0 to 160 0 to 250 0 to 400 0 to 600
D
Electrical Connection D: M12 DC only E: 7/8-16 UN2A AC only
2
With Viewing Window
02
Output 01: DC Analog 420 mA, shunt calibration 02: DC Analog 420 mA, digital single stage 11: DC Analog 010 V, shunt calibration 12: DC Analog 010 V, digital single stage 03: DC digital dual stage 04: AC Relay 120 V
5
Fluid Connection 5: 1/4" BSP female 6: 1/4" NPTF female 9: SAE 7/16-20 UNF female
NOTE: Use this table only to interpret the catalog number. Some combinations are not available. Table 22.8:
AC Versions XMLF010E2046 XMLF070E2046 DC Versions XMLFM01D2026 XMLF010D2026 XMLF070D2029 XMLF400D2029 XMLF010D2039 XMLF070D2039 XMLF400D2039 XMLF010D2036 XMLF070D2036 -14.5 to 0 psi 0 to 145 psi 0 to 1015 psi 0 to 5800 psi 0 to 145 psi 0 to 1015 psi 0 to 5800 psi 0 to 145 psi 0 to 1015 psi Dual stage Analog with single stage 1/4" NPT Female 1/4" NPT Female SAE7/16-20 Female SAE7/16-20 Female SAE7/16-20 Female SAE7/16-20 Female SAE7/16-20 Female 1/4" NPT Female 1/4" NPT Female M12 M12 M12 M12 M12 M12 M12 M12 M12 500 500 500 500 500 500 500 500 500 0 to 145 psi 0 to 1015 psi Relay (2.5 A) Relay (2.5 A) 1/4" NPT Female 1/4" NPT Female SAE7/8-16UNF SAE7/8-16UNF 525 525
Selection
Range Output Pressure Connector Electrical Connector $ Price
Catalog Number
File
E164865
File
LR44087
CCN NKPZ
Class 3211-03
22-6
Discount Schedule
XZCP1141Lp
XZCP1241Lp
XZCP1764Lp
XZCC12FDM40V
XMLGZ001 5.00 2 (6.6) XZCP1141L2 115 (4.06) 13.50 Straight 5 (16.4) XZCP1141L5 270 (9.52) 18.00 black PVR 10 (32.8) XZCP1141L10 520 (18.34) 24.80 2 (6.6) XSZCD101Y 90 (3.17) 13.50 Pre-wired M12 Straight 5 (16.4) XSZCD102Y 190 (6.70) 18.00 female connector with cable yellow PVC 10 (32.8) XSZCD103Y 370 (13.05) 22.50 2 (6.6) XZCP1241L2 115 (4.06) 13.50 90 5 (16.4) XZCP1241L5 270 (9.52) 18.00 10 (32.8) XZCP1241L10 520 (18.34) 24.80 2 (6.6) XZCP1764L2 185 (6.53) 37.50 Pre-wired 7/8" 16UN, Straight 5 (16.4) XZCP1764L5 460 (16.23) 53.00 female connector with cable 10 (32.8) XZCP1764L10 900 (31.75) 40.00 1 (3.3) XZCR1511041C1 65 (2.29) 28.50 Straight female M12M12 jumper cables connector 2 (6.6) XZCR1511041C2 95 (3.35) 27.80 with straight male connector, 1 (3.3) XZCR1512041C1 65 (2.29) 26.30 90 female for splitter box connector 2 (6.6) XZCR1512041C2 95 (3.35) 27.80 a Connector incorporating IDCs (insulation displacement connectors) for quick, direct, in-line connection to cable without a screwdriver or soldering iron.
Table 22.10:
Description
Accessories
Catalog Number XMLZL010 XMLZL008 XMLZL009 Weight g (oz) 15 (0.48) 37 (1.19) 370 (11.90) $ Price 0.50 62.00 124.00
XZCR1511041Cp
Sealing gasket Mounting bracket Cooler for versions with 1/4" BSP fluid connection
XZCR1512041Cp
Table 22.11:
Version
Wiring Configurations
Pin 1 Power supply + Power supply + Power supply Pin 2 Power supply 420 mA Second stage Pin 3 Ground Power supply Power supply Pin 4 + Relay Single stage First stage Pin 5 Relay
AC (5-pin E) DC (4-pin D), analog or single stage DC (4-pin D), dual stage
Table 22.12:
Electrical Connections
AC Connector
1 5
DC Connector
Wiring
2 3 4
1. 2. 3. 4. 5.
Analog
2 1
Dual Stage 1. 2. 3. 4. + Power Supply 2nd Stage Solid-State Output Power Supply 1st Stage Solid-State Output
1. 2. 3. 4.
Display
24 Vdc (1733 Vdc), Analog PNPNPN, N.O. Outputs, 4 Wire 24 Vdc (1733 Vdc), Analog + Shunt Calibration, 4 Wire 24 Vdc (1733 Vdc), Dual Stage N.O. N.C., PNPNPN Outputs, 4 Wire The display shows the pressure in the circuit up to a value of twice the maximum pressure size of the device (for example, XMXF.6000 displays values up to 1200 bar). If the pressure is higher than 130% of the pressure range, the display blinks. The display shows two digits after the decimal point from 1 to 2.5 bar (14.5 to 36.25); one digit after the decimal from 10 to 70 bar (145 to 1015); and no digits after the decimal from 100 to 600 bar (1450 to 8700). In all cases, the display shows no values below 2% at the beginning of the scale. 120 Vac (102132 Vac), N.O. N.C. Relays, Output 2.5 A, 5 Wire
Figure 22.2:
XMLFD2
Figure 22.3:
XMLFE2
M12 x 1
142 (5.59) 10 (0.39) 7/8" 16 UN
129 (5.08)
88 (3.46)
113 (4.45)
164 (6.46)
(1)
15 (0.59)
27 (1.06)
15 (0.59)
46 (1.81)
(1) Female fluid entry: XMLF D25: G 1/4 A (BSP) XMLF D26: 1/4 NPTF XMLF D29: SAE 7/16-20UNF
58 (2.28) 138 (5.43) dimension with cover open (1) Female fluid entry: XMLF E25: G 1/4 A (BSP) XMLF E26: 1/4 NPTF XMLF E29: SAE 7/16-20UNF
(1)
88 (3.46)
27 (1.06)
46 (1.81)
Discount Schedule
22-7
119 (4.69)
16 (0.63)
22
Pressure Switches
New!
XML international pressure switches meet IEC, Cenelec, UL and CSA standards. They are CE marked. Fixed differential (XMLA), adjustable differential single-pole (XMLB) or double-pole (XMLC), and dual stage (XMLD) Range listed is on increasing pressure (psi, bar, kPa) External pressure setting window available 1 N.O.1 N.C. snap acting contacts standard Temperature range: 13 to +158 F (25 to +70 C) Enclosure rating: IP65 with plug-in connector, IP66 with terminal connections Operating rate: up to 120 operations per minute for diaphragm and 60 per minute for piston Media connection: 1/4" NPT Conduit connection: 1/2" NPT Table 22.13:
Enclosure Rating Ambient Temperature (Operation) Repeat Accuracy Fluids Controlled Operating Rate
Specifications
Screw terminal models: IP66 conforming to IEC/EN 60529 Connector models: IP65 conforming to IEC/EN 60529 25 to +70 C (13 to +158 F) < 2% Hydraulic oils, air, fresh/sea water (0 to +160 C) Steam, corrosive fluids, viscous products (0 to +160 C) Piston version switches: 60 cycles per minute above 0 C Diaphragm version switches: 20 cycles per minute above 0 C ~AC-15; B300 (Ue = 240 V, Ie = 1.5 A-Ue = 120 V, Ie = 3A) = DC-13; R300 (Ue = 250 V, Ie = 0.1) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1 Silver tipped contacts XMLA & XMLB: 1 C/O single-pole contact (4 terminal), snap action XMLC: 2 C/O single-pole contacts (8 terminal), simultaneous snap action XMLD: 2 C/O single-pole contacts (8 terminal), staggered snap action < 25 m conforming to NF C 93-050 method A or IEC 255-7 category 3 Conforming to CENELEC EN 50013 10 A cartridge fuse type gG (gI) recommended Screw clamp terminals Clamping capacity, min: 1 x 0.2 mm2, max: 2 x 2.5 mm2
22
PRESSURE, VACUUM, AND FLOAT SWITCHES XMLB XMLD
Operations Characteristics
Type of Contacts Resistance Across Terminals Terminal Referencing Short-Circuit Protections Connection
Table 22.14:
Pressure Switch Catalog Number XMLAM01V / XMLM02V XMLBM03S XMLM05A XMLBL05S XMLL35R XMLL35S XML001S XML002A XML002B XMLA004A XMLB004A XML004B XML010A XML010B XML020A / XML035A XML020B / XML035B XML070D / XML160D XML300D XML500D a X2GNiMo 17-12-2 (AISI 316L) b X8GNiS 18-09 (AISI 303)
S
Electrical Connection S Without connector (not available on solid-state devices) C Square / DIN 43650 D D12 Micro connector
Rated Pressure Code psi L05 0 to 0.725 L35 0 to 5.075 B Adjustable differential, M01 -14.5 to -4.06 single-pole contact M02 -14.5 to -2.03 M03 -2.9 to -.029 C 2 adjustable differential, M05 -7.25 to 72.5 single-pole contacts, 001 0 to 14.5 simultaneous 002 0 to 36.25 004 0 to 58 D 2 fixed differential, 010 0 to 145 single-pole contacts, 020 0 to 290 staggered 035 0 to 507.5 040 0 to 580 070 0 to 1015 160 0 to 2320 300 0 to 4350 500 0 to 7250
Actuator Scale Diaphragm 1 Without (XMLD only) A Hydraulic oil, air, fresh/sea water (0 to 70C) 2 With (not available B Hydraulic oil, air, fresh/sea water on solid state (0 to 160C) devices) C Corrosive fluids P Viscous fluids R Hydraulic oil, air (0 to 160C) S Fresh/sea water, corrosive fluids (0 to 160C) Vacuum V Hydraulic oil, air, fresh/sea water (0 to 70C) T Hydraulic oil, air, fresh/sea water (0 to 160C) Piston D Hydraulic oil E Fresh / sea water
Output Fluid Connection 1 Contacts Fluid Electrical 1 1/4 Gas Type 13 (PG 13,5)
2 1/4 Gas
ISO M20
NOTE: Use this table only to interpret the catalog number. Some combinations are not available.
22-8
Pressure Switches
www.schneider-electric.us
Table 22.16:
Fixed Single-Pole Contact (XMLA) -4.06 to -14.5 0.435 to 14.5 2.17 to 36.25 5.8 to 58 8.7 to 145 10.2 to 290 21.75 to 507.5 72.5 to 1015 145 to 2320 290 to 4350 435 to 7250 0.84 to 5.07 -1.74 to -14.5 1.74 to 14.5 4.93 to 36.25 5.8 to 58 17.4 to 145 2.14 to 20 63.8 to 507.5 136.3 to 1015 239.25 to 2320 522 to 4350 594.5 to 7250 3.5 0.29 low / 0.58 high 1.88 5.07 7.25 5.8 low / 14.5 high 18.12 43.5 low / 108.75 high 79.75 low / 261 high 239.25 low / 507.5 high 290 low / 652.5 high 0.44 1.45 0.44 low / 1.02 high 2.03 low / 2.76 high 2.18 low / 2.76 high 6.53 low / 8.7 high 10.15 low / 18.85 high 21.75 low / 37.7 high 72.5 low / 137.75 high 127.6 low / 290 high 246.5 low / 609 high 304.5 low / 942.5 high 130.5 32.62 130.5 130.5 326.25 652.5 1160 2320 5220 9787.5 16312.5 32.62 130.5 32.62 130.5 130.5 326.25 652.5 1160 2320 5220 9787.5 16312.5 XMLAM01V2S13 XMLA001S2S13 XMLA002A2S13 XMLA004A2S13 XMLA010A2S13 XMLA020A2S13 XMLA035A2S13 XMLA070D2S13 XMLA160D2S13 XMLA300D2S13 XMLA500D2S13 XMLDL35S1S13 XMLDM02V1S13 XMLD001S1S13 XMLD002B1S13 XMLD004B1S13 XMLD010B1S13 XMLD020B1S13 XMLD035B1S13 XMLD070D1S13 XMLD160D1S13 XMLD300D1S13 XMLD500D1S13 300.00 300.00 279.00 310.00 310.00 270.00 310.00 476.00 476.00 476.00 476.00 793.00 635.00 793.00 857.00 857.00 857.00 857.00 857.00 699.00 699.00 699.00 825.00
14
XMLC
2 C/O single-pole contacts, simultaneous snap action
13 11 23 24 21 22
14
12
12
XMLD
2 C/O single-pole contacts, snap action (1 per stage)
23 24 13 11 21 22
14
12
Table 22.17:
Adjustable Single-Pole Contact (XMLB) 0.038 to 0.72 0.65 to 5.07 -2 to -14.5 -0.29 to -2.9 -7.25 to 72.5 0.72 to 14.5 4.35 to 36.25 3.62 to 58 10.15 to 145 18.9 to 290 50.75 to 507.5 101.5 to 1015 145 to 2320 319 to 4350 435 to 7250 0.65 to 5.07 -2 to -14.5 -7.97 to 72.5 0.725 to 14.5 4.35 to 36.25 4.35 to 58 10.15 to 145 18.85 to 290 50.75 to 507.5 101.5 to 1015 174 to 2320 319 to 4350 435 to 7250 0.02 low / 0.06 high 0.6 low / 0.72 high 1.9 0.26 7.25 0.58 low / 0.87 high 2.32 low / 3.04 high 2.9 low / 3.62 high 8.26 low / 12.32 high 14.5 low / 23.2 high 24.65 low / 36.97 high 68.15 low / 127.6 high 134.85 low / 301.6 high 281.3 low / 536.5 333.5 low / 762.7 high 0.29 low / 0.51 high 1.89 low / 2.03 high 6.52 0.43 low / 0.58 high 1.89 low / 2.47 high 2.18 low / 2.47 high 6.53 low / 10.15 high 10.15 low / 14.5 high 14.5 low / 21.75 high 65.25 low / 129.05 high 130.5 low / 304.5 high 232 low / 507.5 high 275.5 low / 754 high 1.63 32.62 130.5 29 163.12 32.62 130.5 130.5 326.25 652.5 1160 2320 5220 9787.5 16312.5 32.62 130.5 163.12 32.62 130.5 130.5 326.25 652.5 1160 2320 5220 9787.5 16312.5 XMLBL05S2S13 XMLBL35R2S13 XMLBM02V2S13 XMLBM03S2S13 XMLBM05A2S13 XMLB001S2S13 XMLB002A2S13 XMLB004A2S13 XMLB010A2S13 XMLB020A2S13 XMLB035A2S13 XMLB070D2S13 XMLB160D2S13 XMLB300D2S13 XMLB500D2S13 XMLCL35S2S13 XMLCM02V2S13 XMLCM05S2S13 XMLC001S2S13 XMLC002B2S13 XMLC004B2S13 XMLC010B2S13 XMLC020B2S13 XMLC035B2S13 XMLC070D2S13 XMLC160D2S13 XMLC300D2S13 XMLC500D2S13 452.00 452.00 425.00 482.00 482.00 300.00 302.00 290.00 310.00 328.00 310.00 310.00 476.00 518.00 518.00 568.00 534.00 568.00 586.00 650.00 650.00 650.00 650.00 650.00 585.00 585.00 585.00 585.00
XMLZL006
XMLZL002
Table 22.18:
Description
XMLZL001
Rear fixing bracket For vibrations > 2 gn Additional top support bracket For vibrations > 4 gn
XMLZL002
41.40
XMLZL011
Lead sealable protective cover To prevent unauthorized access to the adjustment screws and the switch cover mounting screw Lead sealable protective cover To prevent unauthorized access to adjustment screws
XMLZL001 XMLZL011
41.40 41.40
Discount Schedule
22-9
22
Pressure Switches
Figure 22.4: Dimensions
(2)
37
37
113
(1) 56
23
20-22
120
(1) 1 fluid entry, tapped G 1/4 (BSP female) or 1/4 NPT (2) 1 electrical connections entry, tapped M20 x 1.5 or Pg 13.5, or 1/2 NPT : 2 elongated holes 5.2 x 6.7 XMLM02, XML002, XMLB004, XMLC004, XMLD004
XMLC / D: 90 XMLA / B: 77.5
55
XMLC / D: 46 XMLA / B: 35
5.2
106
17.5
158
34
(1) 30 122
13
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
= 37-40
(2)
(1) 1 fluid entry, tapped G 1/4 (BSP female) or 1/4 NPT (2) 1 electrical connections entry, tapped M20 x 1.5 or Pg 13.5, or 1/2 NPT : 2 elongated holes 10.2 x 5.2
22-10
Pressure Switches
www.schneider-electric.us
Industrial, Type G
Class 9012 / Refer to Catalog 9012CT9701
Table 22.19:
UL Listed and CSA Certified As Industrial Control Equipment Range On Decreasing Pressure psig
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing 0.210 140 1.575 3150 5250 13425 20675 0.4 0.1 1.2 0.3 2.2 0.4 4.2 1 7.4 2 13 3 19 5 100 100 240 475 750 850 2000 GRO1 GRO3 GRO4 GRO5 GRO6 GSO1 GSO2 378.00 341.00 300.00 261.00 300.00 378.00 378.00 GRG1 GRG3 GRG4 GRG5 GRG6 GSG1 GSG2 392.00 354.00 314.00 275.00 314.00 392.00 392.00
Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-Ring, Teflon Retaining Ring 201000 902900 1705600 2709000 49 10 141 15 200 40 350 45 10000 15000 20000 25000 GTO1 GTO2 GTO3 GTO4 590.00 590.00 590.00 590.00 GTG1 GTG2 GTG3 GTG4 606.00 606.00 606.00 606.00
NEMA 1
Table 22.20:
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing 0.210 140 1.575 3150 5250 13425 20675 0.40.9 1.23.6 2.26.6 4.213.2 7.433.6 1337.2 1958.8 100 100 240 475 750 850 2000 GNO1 GNO3 GNO4 GNO5 GNO6 GPO1 GPO2 390.00 354.00 318.00 278.00 318.00 390.00 390.00 GNG1 GNG3 GNG4 GNG5 GNG6 GPG1 GPG2 404.00 369.00 333.00 293.00 333.00 404.00 404.00
Open Type
Table 22.21:
Modification
Available Modifications
Applies to GNG, GNO, GRG, GRO1 only All other GNG, GNO, GPG, GPO, GRG, GRO, GSG, GSO Not available on GNG, GNO, GRG, GRO1. Available on all other GNG, GNO, GPG, GPO, GRG, GRO, GSG, GSO GNG, GNO, GRG, GRO1 only All other GNG, GNO, GPG, GPO, GRG, GRO, GSG, GSO GNG, GNO, GRG, GRO GNG, GNO, GRG, GRO GNG, GNO, GPG, GPO, GQG, GQO, GRG, GRO, GSG, GSO, GTG, GTO Form Q1 Q1 Q3 Q4 Q4 Z Z16 Z18 $ Price Addition 270.00 57.00 86.00 309.00 86.00 95.00
Standard Nitrile (Buna-N) diaphragm in #316 stainless steel housing Ethylene propylene diaphragm in #316 stainless steel housing Viton fluorocarbon diaphragm in #316 stainless steel housing 1 418 NPT external thread pressure connection 1214 NPT external thread, 1418 NPTF internal thread pressure connection. Standard actuator only. 7 1620 UNF-2B internal thread pressure connection
Table 22.22:
Description
Stainless steel surge reducer for use on oils, coolants, and hydraulic fluids (not recommended for air or water)
Acceptable Wire Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-22 AWG Recommended Terminal Clamp Torque. . . . . . . . . . . . . . . . . . . . . . . . . 7 lb-in Electrical Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-14 Temperature Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-14 Renewal Parts Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-26
File CCN
E12158 NKPZ
File Class
LR25490 3211-03
CP1
Discount Schedule
22-11
22
Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-Ring, Teflon Retaining Ring
Pressure Switches
Class 9012 single stage pressure switches are control circuit rated devices used in pneumatic or hydraulic systems on a wide variety of machine and process applications to protect the equipment and control or monitor the system pressure. Type G machine tool switches are available with NEMA Type 4, 4X, and 13 (IEC IP66) enclosure ratings. The NEMA 7 and 9 devices are UL listed for use in the following hazardous locations: Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Enclosure materials are cast aluminum. To ensure repeatability and minimize setting drift, pressure settings should fall within the middle 80 percent of the pressure range.
Table 22.23:
Table 22.25:
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
UL Listed and CSA Certified As Industrial Control Equipment Range on Decreasing Pressure psig cApproximate Differential at Mid-Range psig
UL Listed and CSA Certified As Industrial Control Equipment Range on Decreasing Pressure psig cAdjustable Differential Approximate at Mid-Range
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing .210 0.6 0.1 100 GDW1 414.00 GDW21 140 1.6 0.4 100 GDW2 359.00 GDW22 1.575 3.0 0.5 240 GDW4 359.00 GDW24 3150 6.0 0.8 475 GDW5 350.00 GDW25 5250 10.0 1.5 750 GDW6 350.00 GDW26 13425 16 3.5 850 GEW1 491.00 GEW21 20675 27 5 2000 GEW2 698.00 GEW22 Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring Viton 201000 59 9 10000 GFW1 741.00 GFW21 902900 170 15 15000 GFW2 741.00 GFW22 1705600 289 55 20000 GFW3 741.00 GFW23 2709000 495 70 25000 GFW4 851.00 GFW24
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing .210 0.62 100 GAW1 450.00 GAW21 140 1.68 100 GAW2 395.00 GAW22 1.575 3.515 240 GAW4 395.00 GAW24 3150 6.030 475 GAW5 386.00 GAW25 5250 10.049 750 GAW6 386.00 GAW26 13425 1690 850 GBW1 527.00 GBW21 20675 27130 2000 GBW2 734.00 GBW22 Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Retaining Ring Viton Fluorocarbon Diaphragm and O-ring, Teflon 201000 59200 10000 GCW1 777.00 GCW21 902900 170560 15000 GCW2 777.00 GCW22 1705600 2891260 20000 GCW3 777.00 GCW23 2709000 4951900 25000 GCW4 894.00 GCW24
Table 22.24:
Non-adjustable Differential NEMA 7 & 9 Enclosure Class I & II, Division 1 & 2, Groups C, D, E, F, G
Maximum Allowable Pressure psig Single Pole Double Throw Type $ Price Double Pole Double Throw Type $ Price
Table 22.26:
Adjustable Differential NEMA 7 & 9 Enclosure Class I & II, Division 1 & 2, Groups C, D, E, F, G
Maximum Allowable Pressure psig Single Pole Double Throw Type $ Price Double Pole Double Throw Type $ Price
UL Listed As Industrial Control Equipment b Range on Decreasing Pressure psig cApproximate Differential at Mid-Range psig
UL Listed As Industrial Control Equipmentb Range on Decreasing Pressure psig cAdjustable Differential Approximate at Mid-Range
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing 0.210 1.0 0.1 100 GDR1 1389.00 GDR21 1457.00 140 2.4 0.8 100 GDR2 1341.00 GDR22 1412.00 1.575 4.5 1 240 GDR4 1326.00 GDR24 1391.00 3150 9 1.5 475 GDR5 1290.00 GDR25 1355.00 5250 15 3 750 GDR6 1290.00 GDR26 1355.00 13425 25 7 850 GER1 1493.00 GER21 1560.00 20675 41 10 2000 GER2 1731.00 GER22 1799.00 Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 201000 89 18 10000 GFR1 1781.00 GFR21 1848.00 902900 255 30 15000 GFR2 1781.00 GFR22 1848.00 1705600 578 110 20000 GFR3 1781.00 GFR23 1848.00 2709000 788 140 25000 GFR4 1781.00 GFR24 1848.00 Acceptable Wire Sizes: 1222 AWG Recommended Terminal Clamp Torque: 7 lb-in Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-14 Temperature Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-14 Modifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-16 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-16 Renewal Parts Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-26 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-15
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing 0.210 1.02 100 GAR1 1431.00 GAR21 140 2.48 100 GAR2 1385.00 GAR22 1.575 4.515 240 GAR4 1368.00 GAR24 3150 935 475 GAR5 1332.00 GAR25 5250 1549 750 GAR6 1332.00 GAR26 13425 2590 850 GBR1 1535.00 GBR21 20675 41130 2000 GBR2 1769.00 GBR22 Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 201000 89200 10000 GCR1 1823.00 GCR21 902900 255560 15000 GCR2 1823.00 GCR22 1705600 5781260 20000 GCR3 1823.00 GCR23 2709000 7881900 25000 GCR4 1823.00 GCR24 a b c
For metric threads, add M after the W on all types. Price adder $8.50. UL Marine Listed for use on vessels greater than 65 feet long where ignition protection is required. Differential adds to range setting and determines operating point on rising pressure. Complies with IEC 60957.5.1, 5C8.3.4 when protected with a Bussman CCKTK-R-10 fuse. File E12443 Haz. Loc. File E12158 File E12158 CCN NOWT CCN NKPZ CCN NTHT G*R G*O, G*G, G*W Marine Use, G*W
22-12
CP1
Discount Schedule
Pressure Switches
www.schneider-electric.us
UL Listed and CSA Certified As Industrial Control Equipment a Working Pressure Range on Decreasing X (upper) Actuator
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing 075 0175 0500 0.2510 0.536 3175 15825 0.82 515 2290 80200 100 240 850 7500 GGW1 GGW4 GHW1 GJW1 894.00 788.00 917.00 1697.00 GGW21 GGW24 GHW21 GJW21 950.00 849.00 977.00 1758.00
9012GGW1
Piston Actuated#440 Stainless Steel Piston. #303 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring 05000
Type G dual stage pressure switches are designed for use in applications where two separate pressure operations must be controlled by a single pressure monitoring device. These controls are most commonly used where dual functions are required or in sequencing applications such as alarm, followed by shutdown. Table 22.28: Dual Stage Pressure Switch NEMA 4, 4X, 13 Enclosure
Add Adjustable Spread to Range Setting to Obtain Decreasing Operating Point of Stage 2 Fixed DifferentialAdd to Low (Decreasing) Operating Point to Obtain Approximate High (Rising) Operating Point of Each Stage Stage 1 Stage 2 Maximum Allowable Pressure psi SPDT Each Stage Type
UL Listed and CSA Certified As Industrial Control Equipment a Range Setting Limits of Pressure Between Which Stage 1 Can Be Adjusted to Operate on Decreasing Pressure
$ Price
Diaphragm ActuatedNitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing .210 140 1.575 3150 5250 13425 20675 201000 902900 1705600 2709000 a 15 420 630 1275 22110 40180 45250 50300 140800 3001700 5002500 1.0 0.2 4.0 1.0 5.0 1.5 8.0 2.0 14 3 20 4 30 6 50 10 140 30 275 60 400 80 1.5 0.4 6.0 1.5 8.0 2.0 12 3 21 5 30 7.5 45 11 75 19 210 52 400 100 800 150 100 100 240 475 750 850 2000 10000 15000 20000 25000 GKW1 GKW2 GKW4 GKW5 GKW6 GLW1 GLW2 GMW1 GMW2 GMW3 GMW4 635.00 579.00 579.00 567.00 567.00 590.00 590.00 773.00 773.00 773.00 773.00
Piston Actuated#400 Stainless Steel Piston. #300 Stainless Steel Housing, Viton Fluorocarbon Diaphragm and O-ring, Teflon Retaining Ring
9012GKW1
UL Marine Listed for use on vessels greater than 65 feet long where ignition protection is not required.
Ordering
1. Specify Class 9012 Type..., and indicate the high or low operating point for each stage within the limits shown in the above table. Example: Class 9012 Type GKW4 Set: Stage 1 at 30 psi decreasing pressure Stage 2 at 50 psi decreasing pressure (20 psi spread) Differential of each stage will be approximately as shown in the table above. For available modifications see page 22-16. If one or more of these modifications are desired, add the appropriate Form to the Class and Type. Arrange form letters in alphabetical order when ordering more than one modification.
2.
Acceptable Wire Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-22 AWG Recommended Terminal Clamp Torque. . . . . . . . . . . . . . . . . . . . . . . . . 7 lb-in Electrical Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-14 Temperature Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-14 Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-16 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-16 Renewal Parts Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-26 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-15
File LR25490
Class 3211-03
CP1
Discount Schedule
22-13
22
Pressure Switches
Table 22.29:
Contacts
Make VA 7200 7200 7200 7200 7200 7200 7200 7200 A 6 3 1.5 1.2 6 3 1.5 1.2
Break
SPDT
DPDT
Table 22.30:
Type G Industrial
Contact Arrangement 1 N.O. 1 N.C. (600 Vdc rating does not apply) Contact Symbol
Table 22.34:
Type
1 N.O.1 N.C.
Same Polarity
Media
+120C (+250F)
2 N.O.2 N.C.
Same Polarity
Figure 22.5:
Types GAW, GBW, GCW, GDW, GEW, GFW, GKW, GLW, and GMW Machine Tool Switches (except 1, 21)
3.50 89 Form K 1.13 29 0.88 22 Form K1 0.17 4 3.60 91 Forms G17, G18, G19, G20, G21, G22, & T4 0.27 7 Dia. (2) Mtg. Holes
Note: Snap switch contains two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of the same polarity.
Figure 22.6:
0.48 12
0.38 10
2.72 69 2.30 58
2.72 69
0.38 10 1/2 - 14 NPT Conduit Connection 1.22 31 1/4 - 18 NPTF Pipe Thread 0.58 15 1.61 41
X: Conduit connection: GW = 1/2-14 NPT; GWM = 20MMBGS4568, Form M12 = Pg13.5; DIN40430. Y: Pressure connection: GW = 1/4-18 NPTF; GWM = 8; Form M14 = G 1/4 BS 2779; RP1/4 ISO 711; R 1/4 DIN 2999; GJ 1/4 UN1339.
Table 22.32:
Type
Figure 22.7:
GAW, GDW, GKW 2, 4, 5, 6 22, 24, 25, 26, 52, 54, 55, 56 GBW, GEW, GLW 1, 2, 21, 22, 51, 52 GCW, GFW, GMW 1, 2, 3, 4 21, 22, 23, 24, 51, 52, 53, 54
Table 22.33:
Type / Tipo / Type GAR1, 2, 21, 22 GAR4, 5, 6, 24, 25, 26 GBR1, 2, 21, 22; GCR1, 21 GCR2, 3, 4, 22, 23, 24 GDR1, 2, 21, 22 GDR4, 5, 6, 24, 25, 26 GER1, 2, 21, 22; GFR1, 21 GFR2, 3, 4, 22, 23, 24
M 3/4-14 NPT
22-14
Same Polarity
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
Note: Contacts are single pole, double throwone circuit normally open and one circuit normally closed. These circuits are not electrically separate and can not be used on opposite polarities.
Note: Snap switch contains two double-break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of same polarity. Type Contact Arrangement Contact Symbol
Table 22.31:
Ambient
Temperature Ratings
Actuator All Diaphragm Piston All with Forms Q4 and Q14 Minimum -23 C (-10 F) -40 C (-40 F) -26 C (-15 F) -26 C (-15 F) Maximum +85C (+185F)
5.78 147
Pressure Switches
www.schneider-electric.us
Figure 22.8:
9012G Dimensions
GGW1, 21
2.31 59 5.05 128 4.38 111 1.44 37 X 7.98 203 X 1.89 A 48 A 3.50 89 2.72 69
GGW4, 24
Section AA 1.67 42 1/4 Bolt or Screw
7.52 195
M (4) 0.28 7
1.31 33
7.08 180
3.76 96
2.47 63 1.61 41
Y C
GJW1, 21
3.50 89 2.72 69 X 2.63 67 A Section AA 1.67 42 1/4 Bolt or Screw X 1.73 A 44 A 2.72 69 3.50 89
GHW1, 21
Section AA 1.67 42 1/4 Bolt or Screw
2.72 69
7.08 180
6.76 172
M (2)
0.27 7
3.20 81
Figure 22.9:
9012GNO1, GRO1
Type GNO, GRO 3, 4, 5, 6 GPO, GSO 1, 2, 3 GQO, GTO 1, 2, 3, 4 2009 Schneider Electric All Rights Reserved
22-15
22
Dim. =
in. mm
2.63 67
1.22 32
Pressure Switches
NOTE: Refer to discount schedule CP1 unless otherwise indicated. Table 22.35:
Modification Lock on rising pressure, manual reset only 120 Vac or Vdc neon pilot light 24 Vdc only LED 24 Vdc LED pilot light with green lens SPDT snap switch rated 1.1 A at 125 Vdc (minimum differential doubles) Prewired 5-pin Brad Harrison male receptacle #41310 or interchangeable Crouse-Hinds receptacle at our convenience. For use with Brad Harrison female portable plug #41306, 41307, 41308 or equal. Micro connector, 4-pin, for 24 Vdc pilot light External range adjustment (includes knob and range scale window) External range adjustment slotted for screwdriver (includes range scale window) Pg 13.5 conduit thread and 1/419 BSP pressure connection
Available on GAWGJW single pole devices only GW (single pole only), except GAW2 and Form B2. GAWGFW, GAWMGFWM, GKWGMW GAWGFW, GAWMGFWM, GKWGMW GWM only GGW1, GGW 21 only All other GGW, GHW only GAR, GAW, GDR, GDW, GAWM, GDWM, GKW1, 21 only All other GAR, GBR, GDR, GER, GAW, GBW, GDW, GEW, GAWM, GBWM, GDWM, GEWM, GKW, GLW Available on all GGW, GHW except GGW1, 21 Available on all GAR, GBR, GDR, GER, GAW, GBW, GDW, GEW, GAWM, GBWM, GDWM, GEWM, GKW, and GLW, except Types 1 and 21 GGW1, 21 only All other GGW, GHW GAR, GAW, GBR, GBW, GDR, GDW, GER, GEW, GAWM, GBWM, GDWM, GEWM, GKW1, 21 only All other GAR, GAW, GBR, GBW, GDR, GDW, GER, GEW, GAWM, GBWM, GDWM, GEWM, GKW, GLW GAWGMW, GAWMGFWM All 9012G GAR, GAW, GDR, GDW, GGW, GKW Not available in combination with Forms Q1, Q3, Q4. GAR, GAW, GDR, GDW, GGW, GKW Not available in combination with Forms Q1, Q3, Q4. GARGFR; GAWGMW Not available in combination with Forms Q1, Q3, Q4.
152.00 152.00 50.00 35.60 18.90 543.00 114.00 270.00 57.00 171.00 86.00 617.00 171.00 309.00 86.00 17.90 95.0
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
Range scale window (standard with Forms K and K1) Special setting specified (If indicating only one special setting, specify whether this setting is on increasing or decreasing pressure. ) 1/4"-18 NPT external thread pressure connection 1/2"-14 NPT external thread, 1/4"-18 NPTF internal thread pressure connection 7/16"-20 UNF-2B internal thread pressure connection
Table 22.36:
Modification
Factory Modifications for Renewal Parts Kits for Class 9012 Pressure Switches Suffixes for renewal parts kits, see page 22-26.
Applies to Parts Kit Type PC313 PC177179, PC268, 269 PC265267 b PC177178, PC268, 269 PC266, 267 b PC177178, PC268, 269 PC265267 PC265269 b PC265269 PC177, 178, PC265273 b Form H3 Q1 Q3 Q4 Z Z16 Z18 $ Price 64.00 57.00 86.00 28.70 86.00 35.60 96.00
SPDT snap switch rated 1.1 A at 125 Vdc (minimum differential doubles) Standard Nitrile (Buna-N) diaphragm in #316 stainless steel flange Ethylene propylene diaphragm in #316 stainless steel flange Viton fluorocarbon diaphragm in #316 stainless steel flange
1/4"-18 NPT external thread pressure connection 1/2"-14 NPT external thread, 1/4"-18 NPTF internal thread pressure connection 7/16"-20 UNF-2B internal thread pressure connection b Refer to discount schedule CP7G.
Table 22.37:
Description
Stainless steel surge reducer for use on oils, coolants, and hydraulic fluids (not recommended for air or water)
22-16
CP1
Discount Schedule
Vacuum Switches
www.schneider-electric.us
Table 22.39:
Description
Available Modifications
Form F V1 Z Z16 $ Price 24.60 17.90 64.00
Mounting feet (GAW1 and GAW21 only) Range scale window 1/4"-18 NPT external thread pressure connection 1/2"-14 NPT external thread, 1/4"-18 NPTF internal thread pressure connection (standard actuator only)
File E12443 Haz Loc CCN NOWT G*R File E12158 CCN NKPZ G*W CCN NTHT Marine Use, G*W File E12158
File LR25490 Type GAW only File LR26817 Type GAR only (NEMA 7 and 9 Haz Loc)
Table 22.40:
Cut-out Range (In. of Hg)
525 510 020 2 1/4"-18 NPSF Note: Maximum allowable positive pressure: 150 psig. In. of Hg = inches of mercury.
Table 22.41:
Description
Available Modifications
Form E F R Z $ Price 29.00 19.20 14.40
3-way levernameplate marked: Float onlyVacuum and FloatContinuous (factory modification only) Mounting bracket (for retrofit, order 9049A53 bracket kit) Reverse actionnormally open contacts 1/4" male pipe connection (1/4"-18 NPT, external thread) (for retrofit, use 1/4" pipe nipple)
Table 22.42:
Class 9016 Type GVG1 Forms E, F
Voltage
Electrical Ratings9016GVG
AC Single Phase Polyphase 3 hp 5 hp 5 hp DC 1 hp 1 hp 1/2 hp
Table 22.43:
Vacuum Codes
Code J09 J10 J11 J12 J13 J99 38
16.525 1722 1823 2025 Specify other setting (minimum order quantity is 4 pieces)
Ordering Information: Specify Class 9016 Type G. Give vacuum settings within the limits of the listings above. For Setting Codes, see table above. If special features are desired, add the appropriate Form letter to the Class and Type. Arrange the Form letters in alphabetical order when ordering more than one special feature.
File LR25490
CP7G
Discount Schedule
22-17
22
At Minimum Range: 0.89 1 N.O., 1 N.C. 1/4"-18 GAW1 309.00 GAR1 646.00 At Mid-Range: 1.37.4 025 520 1 N.O., 1 N.C. 1/4"-18 GAW2 270.00 N/A At Minimum Range: 19 028.3 2 N.O., 2 N.C. 1/4"-18 GAW21 338.00 GAR21 677.00 At Mid-Range: 1.77.4 025 520 2 N.O., 2 N.C. 1/4"-18 GAW22 330.00 N/A a Add Differential to Range to obtain the operating point on increasing vacuum (within vacuum limitations). The differential increases linearly over its range. b The minimum differential doubles with NEMA 7 & 9 enclosures.
Pressure Switch
Class 9013 Type FHG pressure switches are designed for the control of small electrically driven air compressors. Contacts open on pressure rise. Diaphragm actuated. For application data, see page 22-14. For repair parts kits, see page 22-26. Table 22.44:
Adjustable Cut-out Range Increasing Pressure (psig)
Selection Table
Description Approximate Differential Non-adjustable (psig) Pressure Connection 1/4" NPSF internal 3/8" NPSF internal 1/4" four way 1/4" NPT external 1/4" NPSF internal 3/8" NPSF internal 1/4" four way 1/4" NPT external 1/4" NPSF internal 1/4" four way 1/4" NPT external NEMA 1 Enclosure Lower hp Poles Type FHG2 FHG3 FHG4 FHG9 FHG12 FHG13 FHG14 FHG19 FHG42 FHG44 FHG49 $ Price 27.30 27.30 35.10 27.30 27.30 27.30 35.10 27.30 27.30 35.10 27.30 Higher hp Type FHG22 FHG24 FHG29 FHG32 FHG33 FHG34 FHG39 FHG52 FHG54 FHG59 $ Price 39.90 47.60 39.90 39.90 39.90 47.60 39.90 39.90 47.60 39.90
3.76 96
40-100
20
70-150
30
22
1.59 40 0.30 8
100-200
40
Table 22.45:
Description
2.80 2.50 71 64
Bulk pack Addition of a second ground screw Maintained manual cut-out lever (Auto-Off) Pulsation plugfactory order only (available only on 1/4-inch fittings, not to include 4-way) 1/2" conduit bushing1/2" long threadon left Slip-on connectors (load side terminals only) Slip-on connectors (line and load terminals) Factory sealed range stud Two-way pressure release valve Quick connect two-way pressure release valve (for use with Polyflow tubing) Black cover a b
Table 22.46:
Switch Type FHG2, 12, 22, 32, 42, 52 FRG2, FSG2, FYG2 FHG3, 13, 33 FRG3, FSG3, FYG3 FHG9, 19, 29, 39, 49, 59 FSG9, FYG9
For bulk package quantities and Form numbers, see Table 22.55 on page 22-19. Refer to discount schedule CP7. If Form is not specified, devices will be shipped individually packaged. Refer to discount schedule CP7I. Can be field installed. Nameplate should then be marked with the Form letter and maintenance and ordering records corrected.
Table 22.48:
Switch Type FHG2, 9, 12, 13, 14, 19, 42, 43, 44, 49 FSG, FSW FHG22, 29, 32, 33, 34, 39, 52, 54, 59 FYG, FYW FRG One Pole All Form H
Table 22.47:
Off at... 80 psi 100 psi 110 psi 115 psi 120 psi 125 psi 135 psi 140 psi 155 psi 150 psi 175 psi
A600
A300
A300
A600
A600
Specify other pressure J99 (minimum order quantity is 4 pieces) Note: The existence of a code does not imply that the code is available for any or all devices.
DC rating does not apply to Form M4. 1/4 hp with Form MI. See 1993 NEC Article 430-84
Ordering Information
File E12158 CCN NKPZ File LR25490
1. 2. 3.
Note: UL Listed control equipment. Type 4 must have Form T; otherwise these Types are component recognized. If conduit or pressure line is rigid, UL; if both are flexible, UR.
Specify Class 9013 Type FHG. Select pressure code from Table 22.47, and add the code designation to end of the Type number. Ensure that the pressure code falls within the limits of the device as shown in Table 22.44. To order special features, add the appropriate Form designation to the Class and Type. Arrange Forms in alphabetical order when specifying more than one special feature.
22-18
CP7
CP7I
Discount Schedule
Designed for the control of electrically driven water pumps. Diaphragm actuated. Type FSG is the standard water pump switch, suitable for all types of pumps: jets, submersible, reciprocating, etc. Type FYG is designed to meet higher horsepower and pressure requirements. Type FRG is reverse acting: contacts open on falling pressure.
Pressure Switch
1/4" NPSF internal FSG2 27.30 FSW2 1/4" NPT external FSG9 27.30 FSW9 2065 1530 545 1/4" bayonet (barbed) FSG10 27.30 FSW10 90 elbow 1/4" bayonet FSG20 30.00 FSW20 2050 1030 1030 1/4" NPSF internal FSG22 34.80 FSW22 2060 1030 1045 1/4" NPT external FSG29 34.80 FSW29 930 620 310 1/4" NPSF internal FSG42 34.80 FSW42 930 620 310 1/4" NPT external FSG49 34.80 FSW49 3465 1530 1945 (FSG1 through 20 with Form M4 Is only available in this range) 1/4" NPSF internal FYG2 39.90 FYW2 1/4" NPT external FYG9 39.90 FYW9 2580 2030 560 1/4" bayonet (barbed) FYG10 39.90 FYW10 90 elbow 1/4" bayonet FYG20 42.30 FYW20 3980 2030 1960 (FYG1 through 20 with Form M4 is only available in this range) 2050 1030 1030 1/4" NPSF internal FYG22 47.30 FYW22 2060 1030 1045 1/4" NPT external FYG29 47.30 FYW29 940 630 310 1/4" NPSF internal FYG42 47.30 FYW42 940 630 310 1/4" NPT external FYG49 47.30 FYW49 c Must be mounted in vertical position to maintain enclosure rating.
Table 22.49:
Settings 521 psi 820 psi 2040 psi 2050 psi 3050 psi 4060 psi 5070 psi 5585 psi 6080 psi
Pressure Codesa
Reverse Action Devices Settings Code Code J15 J16 J20 J18 J21 J24 J33 J34b J25
Table 22.51:
Cut-in Range (psig) 2365
8.55.5 psi J17 105 psi J36 2212 psi J22 2216 psi J19 3520 psi J70 4020 psi J23 5030 psi J35 8060 psi J32b 10080 psi J51b 150120 psi J64b Specify other pressure J99b Specify other pressure J99b a Existence of a code does not imply that the code is available for any or all devices. b Minimum order quantity is 4 pieces.
1045
620
425
614
5 Non-adjustable 2030
19
65150
3045
35120
Table 22.52:
Table 22.54:
Description
Special Features and Modifications for Type FSG, FYG & FRG Devices
Applies to Types All Type F FRG 2-Pole only FSG, FYG FRG2-59 only FSG, FYG Form d H M1 M3 M4 $ Price Addition 9.90 5.10 5.10 8.70
Type FHG, FSG, FYG, FSW, FYW, FRG GHB, GHG, GSB, GSG GMG, GSR, GSW GHR, GHW
Table 22.53:
Operation (Media) Storage Min. -36 C (-33 F) Min. -36 C (-33 F) Max. +125 C (+257 F) Max. +125 C (+257 F) Ordering Information Specify Class 9013 Type F. Select the pressure code from Table 22.49, and add the code designation to the end of the Type number. Ensure that the pressure code falls within the limits of the device as shown in Tables 22.50 and 22.51. To order special features, add the appropriate Form letter to the Class and Type. Arrange the Form letters in alphabetical order when ordering more than one special feature. Electrical Ratings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-18 Dimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22-18 Renewal Parts Kits: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-26
FRG2-59 only M5 5.10 FRG, FSG, FYG Pe 0.74 FSG, FYG, FRG Q8 Plastic flange (max. temp. 120F) (max. pressure 80 psi) 12.00 (available only on Types FSG2, FYG2, FRG2, FSG2, FYG2, FRG2) 1/4" NPSF internal only 1/2" conduit bushing, 1/2" long threadon left All Type F T 4.10 Slip-on connectors (load side terminals only) FSG, FYG U 0.48 Slip-on connectors (line and load terminals) FSG, FYG U2 0.96 Black cover FSG, FYG Z22 d For bulk package quantities and Form numbers, see Table 22.55. Refer to discount schedule CP7. If Form C is not specified, devices will be shipped individually packaged. Refer to discount schedule CP7I. e Nylon pulsation plug can be field installed on types having 1/4" NPSF internal connector. Part number 1530S6G1 is one bag of 50 plugs.
Bulk package One normally openone normally closed contact Maintained manual cut-out lever (Auto-Off) Momentary manual cut-in lever (Auto-Start) Low pressure cut-off (Auto-Start-Off) Operates at approximately 10 psig below cut-in and will turn off the pump Maintained manual cut-in lever (Auto-On) Pulsation plug (Type 2 & 9 only)
Table 22.55:
Description
File LR25490
Note: Products on this page are UL Listed, however type numbers ending in 8, 10 or 20 (non rigid pressure lines) must have Form T or TIotherwise these are UL component recognized.
Bulk Package Quantity 9013FHG (without 1/4" four-way) Product without 9013FHG4, 14, 24, 34, 44, 54 (with 1/4" four-way) Forms M1, M3, 9013FRG M4, M5, T, X1 9013FSG 9013FYG 9013FHG (without 1/4" four-way) 9013FHG4, 14, 24, 34, 44, 54 (with 1/4" four-way) Product with Forms M1, M3, 9013FRG M4, M5 9013FSG 9013FYG 9013FHG (without 1/4" four-way) 9013FHG4, 14, 24, 34, 44, 54 (with 1/4" four-way) Product with 9013FRG Forms T, X1 9013FSG 9013FYG 9013FHG9 Special with Extended Flange
CP7
CP7I
Discount Schedule
22-19
22
40100
2080
Pressure Switch
Class 9013 Type G Pumptrol pressure switches are designed to control electrically driven water pumps and air compressors. These devices cover higher electrical ratings for directly controlling motors in pump and compressor applications. Contacts open on pressure rise. Diaphragm actuated. For electrical ratings, see page 22-18. For repair parts kits, see page 22-26.
File E12158 CCN NKPZ File E12443 CCN NOWT Haz Loc File 25490 File 26817 Haz. Loc.
Table 22.56:
Code J20 J21 J23 J24 J25 J26 J28 J29 J30 J31 J50 J51 J53 J54 J56 J57 J58 J60 J61 J62 J63 J64 J65 J99
Pressure Codes
Table 22.57:
Cut-out Range (psig) 1035 2080 2080
Selection Tables
Cut-in Range (psig) Enclosure Poles 2 2 2 NPSF Internal Pressure Connection 1/4 1/4 1/8 1/4 3/8 1/8 1/4 3/8 1/8 1/4 3/8 1/4 1/8 1/4 3/8 1/8 1/4 3/8 1/8 1/4 3/8 1/4 1/8 1/4 3/8 1/8 1/4 3/8 1/8 1/4 3/8 Type GMG2 GSB2 GSG1 GSG2 GSG3 GSR1 GSR2 GSR3 GSW1 GSW2 GSW3 GHB2 GHG1 GHG2 GHG3 GHR1 GHR2 GHR3 GHW1 GHW2 GHW3 GHB5 GHG4 GHG5 GHG6 GHR4 GHR5 GHR6 GHW4 GHW5 GHW6 $ Price 153.00 149.00 86.00
Pressure Setting (Close-Open) psi 2040 3050 4020 (reverse action) 4060 6080 7090 70100 75100 80100 90120 135175 10080 (reverse action) 100125 110125 110150 120150 125150 125175 130175 140175 145175 150120 (reverse action) 215250 Specify the required setting
5.530.5 NEMA 1 (General Purpose) 560 NEMA 3R a (Rainproof) 560 NEMA 1 (General Purpose)
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
NEMA 7 & 9 (Hazardous Locations) 2080 2040 550 NEMA 4 (Watertight) 65200 65200 2040 2040 40170 40170 NEMA 3R a (Rainproof) NEMA 1 (General Purpose) 2 2 2
453.00
NEMA 7 & 9 (Hazardous Locations) 65200 3050 35150 NEMA 4 (Watertight) 80250 80250 2545 2445 32215 32215 NEMA 3R a (Rainproof) NEMA 1 (General Purpose) 2 2 2
453.00
Ordering Information Specify Class 9013 Type G. Select pressure code from Table 22.56 above, and add code designation to the end of the Type number. Ensure that pressure code falls within the limits of the device as shown in Table 22.57. To order special features, add the appropriate Form letter to the Class and Type. Arrange Form letters in alphabetical order when ordering more than one special feature. Electrical Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 22-18
3.44 87
NEMA 7 & 9 (Hazardous Locations) 80250 4060 30190 NEMA 4 (Watertight) a Must be mounted in vertical position to maintain enclosure rating. 2
453.00
473.00
2.47 63 2.09 53
3.85 98 0.73 18
3.68 99
Table 22.58:
Description
0.42 11
1 18 NPSF 4 Pipe Thread Note: The mounting bracket shown is available as kit 9049A52.
3.75 99
Standard pack of 10 switchesb All Type G 3-way lever (On-Auto-Off) (not compatible with Form X) GHG, GMG, GSG 1 N.O., 1 N.C. contact All Type G Pulsation plug (not field replaceable.) All Type G Reverse action All Type G (Select pressure code from reverse action table on page 22-19) Slip-on connectors (load side terminals only) All Type G Slip-on connectors (line and load terminals) All Type G GHB, GMG, GSB, GHG, GSG Two-way pressure release valve (Not compatible with Form E) GHR, GHW, GSR, GSW 1/4" male pipe thread on pressure connection All Type G 1/2"-14 NPT external All Type G 1/4"-18 NPT internalc b Available on GHB, GHG, GSB, and GSG. If Form C10 is not speciied, devices will be shipped individually packaged c UL Listed industrial control equipment.
Table 22.59:
Type
Description Two-way pressure release valve, replacement only. A12 Cannot be added to switch that originally had no valve. A52 Mtg. bracketreplacing obsolete 9013A with 9013G Mtg. bracketreplacing obsolete 9013A with 9013G, A53 or for current 9016GVG Two-way pressure release valve. Replacement only. A56 Cannot be added to switch that originally had no valve. d Refer to discount schedule CP7G. e Refer to discount schedule CP7.
22-20
CP7G
Discount Schedule
Float Switches
www.schneider-electric.us
Contact Operation
Type DG2
Close on liquid rise DG2 55.00 DW31 366.00 DR31 353.00 Open on liquid rise DG2R 60.00 DW31R 371.00 DR31R 357.00 Close on liquid rise GG2 105.00 GW1 617.00 GR1 603.00 Open on liquid rise GG2R 105.00 GW1R 627.00 GR1R 617.00 Order the universal mounting bracket and float accessory kits separately from the Class 9049 Accessories section on page 22-26. Types GW and GR use a center-hole float. Devices with Form C use a center-hole float. All others use a tapped-at-top float.
Table 22.61:
Description
Modifications
Factory Installed Form R C C CR C CR H CH R Field Installed $ Price 5.10 10.10 10.10 Not available 9049A13 9049A13 Not available Not available Not available 12.60 12.60 $ Price Class 9049 Kit 5.10 10.10 10.10 15.20 12.60 27.50 14.90 27.50 14.90 A58 A19 A20
Types DG, DW, DR Reverse action (Type DG) Compensating spring (Type DG) Compensating spring (Type DR, DW) Compensating spring and reverse action Types GG, GW, GR Compensating spring for Type GG2 Combination of compensating spring and reverse action (Type GG2) 1 N.O., 1 N.C. contact configuration Combination of comp. spring & 1 N.O., 1 N.C. contact for Type GG2 Reverse action (Type GR, GW)
Type GG
Table 22.62:
Table 22.63:
Type
Type (with or without Form H) DG2 9 8 60 GG2 DG2 Form R 8 8 60 GG2 DW31 8 8 66 GG2 Form R DW31 Form R 8 8 66 GG2 Form R DR31 8 8 66 GR1, GW1 GR1, GW1 DR31 Form R 8 8 66 GR1, GW1 c Compensating spring not effective in combination with Short lever length position.
2.53 64 1.44 37
4 Holes Dia. 0.28 7
1.31 33
3.61 97
0.87 Dia. Knockout for 0.50 Conduit in 3 Sides 0.41 Dia. Holes
5.56 141
3.50 89
0.73 19 Pin Position 1.09 "B" Contacts 26 1.87 1.87 Closed in 48 2.18 48 Up Position (Standard action) 55 2.62 67 Short Long
Float lever travel between closing and opening of contacts: short = 1 in. (25 mm), medium = 1.12 (28 mm), long = 1.25 in. (31.8)
Pin Position "A" Contacts Open in 1.12 1.12 Up Position 29 29 Form R 2.87 (Reverse action) 73 1.50 Lever arm travel between closing and opening of contacts Standard: short = 0.375 in. (10 mm), long = 0.625 in. (16 mm) 38 Form R: short = 0.5 in. (13 mm), long = 0.75 in. (19 mm) For Type GR/GW dimensions, see catalog 9034CT9701.
1.37 35
Table 22.64:
Applies to Class and Type 9036DG, DR, DW (2-pole), FG 9036GG, GR, GW (2-pole) 9036G Form H (1 N.O., 1 N.C.) 9037EG, ER, EW; HG, HR, HW (2-pole) 9038 All Devices (2-pole) d See 1993 NEC Article 430-84 2009 Schneider Electric All Rights Reserved
CP7G
Discount Schedule
22-21
22
Item Type A6 Type A6S Type A6C Type A6CS Type A6A Type A6CA Net buoyancyb (in water) 7" float 60a 60a 70a 70a 60a 70a Weight of 5 ft rod 18.5 16.9 18.5 16.9 6 6 Weight of extra ft of rod (per ft) 3.7 3.4 3.7 3.4 1.2 1.2 Total weight of stops 3 (2) 3 (2) 6 (4) 6 (4) 3 (2) 6 (4) a Net buoyancy of float has been calculated with float 80% submerged, thus allowing 20% factor of safety. b Buoyancy data is calculated for use in water. Consult factory for buoyancy data in media with different specific gravity than water. When ordering float accessories, first specify the desired float accessory package, such as 9049A6 or 9049A6CS, then as a second item give the number of additional rod kits required. For example, for a 9049A6 with 15 ft of rod, order as follows: Item A = 9049A6, quantity = 1; Item B = 9049T1, quantity = 4.
Float Switches
Open Tank or Sump Applications, Sumptrol Float Switch, Class 9036 Type FG
The Class 9036 Type FG30 pedestal style float switch is designed for liquid level control with electric motor operated pumps either directly or through a magnetic starter. It can also be used to activate alarms in liquid level control systems. The upward or downward movement of the lever arm of the Class 9036 Type FG30 float switch controls the On and Off positions corresponding to the water level changes required to turn the pump or alarm on and off. Ambient temperature ratings: Min. -30 C (-22 F); Max. +105 C (+220 F) Table 22.65: Type FG Float Switch and Accessories
Class 9036 9049 9049 Type FG30 A60 A61 $ Price 23.30 6.20 6.20
Description 2-pole, NEMA 1, contacts close on liquid rise Plastic center hole float (1 required) 33.75 inch aluminum rod, 2 float stop assemblies and attaching hardware (1 required)
Type FG
of Float
CL of Flange
CL of Flange
22
PRESSURE, VACUUM, AND FLOAT SWITCHES Type EG with 9049ER3 Rod Kit File No. E12158 and E12443 Haz Loc File 25490 except ER8, ER9
For minimum water level change For maximum water level change
Table 22.67:
Description #304 stainless steel #316 stainless steel
Table 22.68:
Type ER1 ER2 ER3 ER5 ER7 ER12 1.00 1.00 1.00 1.00 1.00 1.00
A (in.)
Figure 22.15: Type EG Dimensions For 9037ER/EW dimensions and rod positions, see catalog 9034CT9701
3.69 94 1.11 1.06 28 27 0.25 6 3.97 101 2.69 68 NEMA 1 Enclosure, 2.63 Post 67 2.5 64 Net Weight 4 lb (1.8 kg)
*
DIA. 3.63 92 F 0.97 25
* Short length
(Dimension L)
5.75 146
diameter
Shown with Rod Kit and Float Kit installed, with Pattern for hole in tank. Recommended hole size = 4.19 diameter. 106
22-22
CP7G
Discount Schedule
Float Switches
www.schneider-electric.us
Type H switches are attached to the tank by means of a 2-1/2 inch screw-in connection. An external pointer indicates the float position within the tank when the unit is mounted. Switches come complete with stainless steel float and rod. Buna N Quad-Ring seal is used between the float rod and sealing connector. Normal application is at atmospheric pressure, but where higher pressures are encountered, the switch will withstand tank pressures up to 50 psi at temperatures up to +220 F. Occasional replacement of the Quad-Ring seal may be necessary. Ambient temperature ratings: Min. -30 C (-22 F); Max. +105 C (+220 F) Table 22.69:
Float Position (viewed from front of switch, facing indicator scale)
Max. (in.) Type $ Price Type $ Price Type $ Price 5 HG33 149.00 HW33 462.00 HR33 449.00 5 HG35 149.00 HW35 462.00 HR35 449.00 Right 7 HG37 149.00 HW37 462.00 HR37 449.00 90 Offset 2 8-1/4 HG39 149.00 HW39 462.00 HR39 449.00 11-1/2 HG31 149.00 HW31 462.00 HR31 449.00 45 2 5 HG34 149.00 HW34 462.00 HR34 449.00 5 HG36 149.00 HW36 462.00 HR36 449.00 Left 7 HG38 149.00 HW38 462.00 HR38 449.00 90 Offset 2 HG30 149.00 HW30 462.00 HR30 449.00 8-1/4 11-1/2 HG32 149.00 HW32 462.00 HR32 449.00 Note: For replacement floats, see Class 9049 Type H on page 22-26. Types shaded in gray are available with Form Z19; see Table 22.71 below.
Minimum 6.22 (158) 2.25 (57) 3.00 (76) 4.25 (108) 2.75 (70) 4.25 (108) 5.50 (140) 3.50 (89) 90 offset 5.00 (127) 6.25 (159) 3.75 (95) 7.00 (178) 8.25 (210) 4.75 (121) a Clearance from the centerline of the hub to the side of the tank. 45
R in. (mm)
Ha in. (mm)
f1 in. (mm) Maximum 4.50 (114) 4.25 (108) 5.50 (140) 6.25 (159) 8.25 (210)
f2 in. (mm) Minimum 2.00 (52) 2.25 (57) 2.75 (70) 3.00 (76) 3.75 (95) Maximum 4.50 (110) 4.25 (108) 4.00 (102) 4.50 (110) 5.75 (146)
F in. (mm) Minimum 4.25 (108) 5.00 (127) 6.25 (159) 6.75 (171) 8.50 (216) Maximum 9.00 (229) 7.50 (191) 9.50 (241) 10.75 (273) 14.00 (356)
Table 22.71:
12.44 316
6 17 .94 6
3.86 98
6.22 158
4.44 113
0.38 10
6.22 158
6 17 .94 6
1. 27 06
12.44 316
R Bushing 2.0 Across Flats 51 C L 16.94 430 f2 C L f1 3.63 92 0.38 10 2.58 65 F 11.5 292
0.66 17
2 64 .5 D
ia
6.22 158
7.13 184
6.22 158
CP7G
Discount Schedule
22-23
22
File LR25490
Description Omit 2-1/2" tank connecting bushing Omit float Reverse action, contacts open on rise Viton packing: 5 oz. float (diesel fuel) for Types shaded in gray in Table 22.69 above. Viton packing (suitable for applications up to +250 F) #316 stainless steel float and Viton packing
Table 22.70:
Float Switches
Mechanical alternator AG1 192.00 float operated Note: For use with Class 9049 float accessories listed on page 22-26. Type AW and AR alternators must use center hole floats.
Table 22.73:
6.88 174.75
4.69 119.13
3.63 92.2
1.125 28.58 4.50 114.3 3.0 76.2 1.75 44.45 1.47 37.34 .84 21.34
0.75 19.05
1.25 31.7
Length of Rod That Can Be Maximum Weight of Rod Supported with the and Stops That Can Be Supported By Compensating Compensating Spring at the Type Max. Adjustment Spring (Form C) Force Force Note: AW1 and AR1 have Stainless Aluminum compensating spring standard. Brass a Steel a Upb Down a AG1 (min. lever ext.) 18 oz 20 oz 47 oz. 10 ft 12 ft 25 ft AG1 (max. lever ext.) 16 17 41 8 10 21 AG1 Form R (min. lever ext.) 14 16 33 7 8 17 AG1 Form R (max. lever ext.) 11 12 30 6 7 15 AR1, AW1 (standard lever) 74 16 20 41 AR1, Form R, AW1 Form R (std. lever) 85 19 23 47 a Rod length has been determined using the weight of the rod material furnished on Class 9049 accessories (3/8" O.D. tubing). Other types of rod should be weighed and compared to the Weight of Rod column above. b Add 2 oz for Form N5 High Water alarm.
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
Front
Float on left
Type CG36
File No. E12158 excludes NEMA 7 & 9 products (9038AR, CR, and DR)
Approx. Water Float Position Viewed R from Front of Switch in. (mm) Level Change Facing Indicator Scale Min. (in.) Max. (in.) Right 7 (178) 6.5 (165) 13 (330) Left 7 (178) 6.5 (165) 13 (330) Right 4.25 (108) 4 (102) 7.75 (197) Left 4.25 (108) 4 (102) 7.75 (197) Right 5 (127) 4.75 (121) 9.25 (235) Left 5 (127) 4.75 (121) 9.25 (235)
Table 22.75:
R in. (mm)
File LR25490 excludes NEMA 7 & 9 products (9038AR, CR, and DR)
Min. Max. 7 (178) c 2.5 (64) 5 (127) 5 (127) b 2.25 (57) 3.75 (95) 4.25 (108) a 2 (51) 3.5 (89) a b c
Min. Max. Min. Max. 5 (127) 7 (178) 2 (51) 4 (102) 4 (102) 5.25 (133) 2.75 (70) 3 (76) 3.5 (89) 4.75 (121) 2.5 (64) 3.75 (95)
Min. Max. Min. Max. 5 (152) 7 (178) 10 (254) 14 (495) 4 (102) 5.25 (133) 8 (203) 10.5 (267) 3.5 (89) 4.75 (121) 7 (178) 9.5 (241)
CG33, CG34, CW33, CW34, CR33, CR34 CG35, CG36, CW35, CW36, CR35, CR36 CG31, CG32, CW31, CW32, CR31, CR32
D A F C B 2.5 64
6.5 165 max.
2.63 2.63 67 67 To reverse the float, change the operating link in the holes of the adjusting plate.
22-24
CP7G
Discount Schedule
Float Switches
www.schneider-electric.us
Designed for applications where mounting is to be made at the top of a closed tank. Table 22.76: Class 9038 Type D Contacts Close On Liquid Rise
Hinge Post Dimension V (in.) 2-5/8 4-11/16 NEMA 1 Type DG7 DG8 DG9 DG10 $ Price 495.00 495.00 515.00 515.00 NEMA 4 Type DW7 DW8 $ Price 1026.00 1026.00 NEMA 7 and 9 Type DR8 $ Price 1013.00
Table 22.77:
Table 22.78:
Type ER1 ER2 ER3 ER5 ER7 ER12 R (in.) 1.75 2.50 3.25 5.25 7.25 12.25
File No. E12158 excludes NEMA 7 & 9 products (9038AR, CR, and DR)
Size and Material Diameter x Length (in.) 3.625 x 4.50, #304 stainless steel 3.625 x 4.50, #316 stainless steel 2.50 x 7, #304 stainless steel 2.50 x 7, #316 stainless steel
File LR25490 excludes NEMA 7 & 9 products (9038AR, CR, and DR)
Description Compensating spring (Type AG) Omit 2-1/2 in. connecting bushing (Type CG, CR, CW) Omit float (Type CG, CR, CW) Two-level non-alternating unit Addition of a third, high-water alarm circuit (Type AG, AR, AW, CG, DG only) High-water alarm circuit, 2-pole (Type CG only) Reverse action (contacts open on Rise) Viton packing, 5 oz. float (diesel fuel) (Type CG) Viton packing (Type CG, CR, CW) #316 stainless steel float and Viton packing (Type CG, CR, CW)
$ Price Difference add 40.10 deduct 8.10 deduct 29.30 add 56.00 add 134.00 add 173.00 add 152.00
5.59 142
C of L Flange
1.47(2) PLS 37 5.59 142 4 knockout holes for 0.50.75 (1319) conduit on each end 4.5 114
F 4.41 112
3.63 92
H 0.13 Wide Bead Note: Floats shown are Type EF, 4.5 (114) long. 3 The recommended size of the hole in the tank for the entry of the float and the mounting of the control is 4.19 (106). Add 2.5 (64) to "H" if using Type HF Floats, which are 7.0 (178) long.
Table 22.80:
Media
Ambient Temperature
CP7G
Discount Schedule
22-25
22
Table 22.79: Available Modifications for All Mechanical Alternators Consult the factory for use in media with a different specific gravity than water.
To order, specify the Class and Type number of the kit. Refer to discount schedule CP7G unless otherwise noted. Table 22.81:
Description Compensating Spring #304 stainless steel #316 stainless steel #304 stainless steel Dia. 2.5 in. (64 mm), length 7 in. (178 mm) #316 stainless steel Brass rod 7 in. tapped-at-top #304 stainless steel float, 5 ft rod, 2 stops Aluminum rod Brass rod 7 in. center-hole #304 stainless steel float, 5 ft rod, 4 stops Float Aluminum rod Kit 7 in. center-hole #316 stainless steel float, 5 ft stainless steel rod, 4 stainless steel stops 7 in. tapped-at-top #316 stainless steel float, 5 ft stainless steel rod, 2 stainless steel stops Replacement float7 in. round center-hole #304 stainless steel Lever Form R Replacing obsolete 9036A with 9036G Mounting Replacing 9036A (S or F1) with 9036G Bracket Universal Dia. 3.62 in. (92 mm), length 4.5 in. (114 mm) Float 1-3/4 in. long 2-1/2 in. long 3-1/4 in. long 5-1/4 in. long 7-1/4 in. long 12-1/4 in. long Brass rod Aluminum rod Stainless steel rod
22
PRESSURE, VACUUM, AND FLOAT SWITCHES
Rod
Stainless steel
Rod Kit a
9012GA, GD, GN, GR1, 21 Series C only PC265bc 75.00 9012GA, GD, GG, GK, GN, GR 2, 3, 22, 52 Series C only PC266bc 49.20 9012GA, GD, GG, GK, GN, GR4, 24, 54 Series C only PC267bc 49.20 Diaphragm Assembly Convoluted diaphragm assembly for 9013GHG, GSG: Series C PC208 14.40 9013GHW, GSW; and GSW, GHR: Series C PC211 10.10 9016 GAW-1, 21 PC233 36.20 Gasket Kit Contains all replaceable gaskets for all 9012 open, NEMA 1, 4, 4X, 13 devices PC184 47.60 Pilot Light, 24 Vdc 9012, 9016G Forms G7, G8, G9, G10, G21, G22 PC305c 69.00 9012GC, GF, GJ, GQ, GT1, 21, 31, 41, 51 Series C only PC270bc 492.00 Piston Assembly 9012GC, GF, GJ, GQ, GT2, 22, 32, 42, 52 Series C only PC271bc 492.00 9012GC, GF, GQ, GT4, 24, 34, 44, 54 Series C only PC273bc 492.00 Buna N, for Series A devices: 9037HG/HW/HR3039; 9038CG/CW/CR3136 PC337 14.40 Seal Kit PC338 15.80 Viton, for Series A devices with Form Z19 or Z20: 9037HG/HW/HR3039; 9038CG/CW/CR3136 Buna N Quad-Ring, for Series C devices: 9037HG/HW/HR312; 9038CG/CW/CR16 PC282 43.40 Seal Tube Kit Viton Quad-Ring, for Series C devices: 9 037HG/HW/HR312; 9038CG/CW/CR16 PC333 43.40 SPDT, for 9012GA, GB, GC, GD, GE, GF, GG, GH, GJ single pole; except Forms E2, E3, E4, H3: Series C only PC313bc 119.00 Snap Switch DPDT, for 9012GA, GB, GC, GD, GE, GF, GG, GH, GJ double pole; except Forms E2, E3, H6, H7: Series C only PC314bc 177.00 Switch 9036DR1, DW1 Series B PC285 95.00 Mechanism b If one of these Form designations appears on the pressure switch nameplate, the 9998 PC number must be completed by adding that same Form suffix from page 22-16, and the Form price must be added to the kit price. c Refer to discount schedule CP1. d Refer to discount schedule CP7.
22-26
CP1
CP7G
CP7
Discount Schedule
Table of Contents
Section 23
Relays and Timers
General Purpose Relays
New!
Zelio Plug-in Relays Square D Plug-in Square D Alternating Plug-in Square D Miniature Plug-in Square D Sockets Square D Power
RXM, RPM, RUM, RPF, RSB, RSL Class 8501 Type K Class 8501 Type KA Class 8501 Type R Class 8501 Type N Class 8501 Type C
RXM, p. 23-6
RSL, p. 23-45
Industrial Relays
TeSys IEC Style Relays TeSys D TeSys K TeSys SK CA2SKE Class 8501 Type X 23-15 23-18 23-20 23-20 23-21
Solid StateRelays
Panel Mount DIN Mount SSR Accessories SSRP SSRD SSRAH1, SSRAT1 23-43 23-43 23-43
Timers
Zelio IEC Style17.9 mm Zelio Panel Mounting Zelio Miniature Plug-in Zelio IEC Style22.5 mm Square D General Purpose Plug-in Square D Pneumatic RE11 RE48 REXL RE7, RE8, and RE9 Class 9050 Type JCK Class 9050 Types A and H 23-24 23-24 23-24 23-25 23-28 23-29
CAD32, p. 23-15
9050JCK, p. 23-29
RE7, p. 23-26
ABL8, p. 23-37
Zelio Temperature Controllers24x48 Zelio Temperature Controllers48x48 Zelio Temperature Controllers48x96 Zelio Current Measurement Relays Zelio Voltage Measurement Relays Zelio Phase Measurement Relays Zelio Level Control Relays Zelio Pump Control Relays Zelio Speed Control Relays Zelio Frequency Control Relays Zelio Temperature Control Relays Square D Phase Failure Relays Zelio Count Counters
REG24 REG48 REG96 RM17JC andRM35JA RM17U and RM35U RM17T and RM35T RM35L RM35BA RM35S RM35HZ RM35AT Class 8430 Type MP RC87610
23-44 23-44 23-44 23-30 23-32 23-31 23-33 23-33 23-34 23-34 23-34 23-35 23-36
CA2SKE, p. 23-20
Other Products
New!
Phaseo DC Power Supplies Zelio Analog Interface Modules Zelio Logic 2 Smart Relays Zelio Solid-State Interface Modules Zelio Electromechanical Interface Modules
23-1
23
RXM
Refer to Catalog 8501CT0601
www.schneider-electric.us
Mechanical indication of relay status (standard) Plug-in protection module to protect against electrical spikes Plug-in jumper bars for coil terminals to avoid timeconsuming wiring
RXM2AB1F7
Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 220 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 240 Vac
Catalog Number RXM2AB1JD RXM2AB1BD RXM2AB1ED RXM2AB1FD RXM2AB1B7 RXM2AB1E7 RXM2AB1F7 RXM2AB1P7
Table 23.2:
Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac
Catalog Number RXM2AB2JD RXM2AB2BD RXM2AB2ED RXM2AB2FD RXM2AB2B7 RXM2AB2E7 RXM2AB2F7 RXM2AB2P7
Table 23.3:
Miniature relays with LED without Push Button (sold in lots of 10)
Number and type of contacts - Thermal current (Ith) 2 C/O -12 A Res. 3 C/O - 10 A Res. $ Price ea. 6.80 6.80 6.80 6.80 6.80 6.80 6.80 6.80 Catalog Number $ Price ea. 4 C/O - 8 A Res. Catalog Number RXM4AB3JD RXM4AB3BD RXM4AB3ED RXM4AB3FD RXM4AB3GD RXM4AB3B7 RXM4AB3E7 RXM4AB3F7 RXM4AB3P7 $ Price ea. 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50
Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac
Catalog Number RXM2AB3JD RXM2AB3BD RXM2AB3ED RXM2AB3FD RXM2AB3B7 RXM2AB3E7 RXM2AB3F7 RXM2AB3P7
23
RELAYS AND TIMERS RXM4GB2F7
Table 23.4:
Miniature relays with low level contacts, without LED (sold in lots of 10)
4 C/O -3 A Res.
Table 23.6:
Number and type of contacts - Thermal current (Ith) Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac Catalog Number RXM4GB1JD RXM4GB1BD RXM4GB1ED RXM4GB1FD RXM4GB1B7 RXM4GB1E7 RXM4GB1F7 RXM4GB1P7 $ Price ea. 7.10 7.10 7.10 7.10 7.10 7.10 7.10 7.10
Miniature relays with low level contacts, with LED without Push Button (sold in lots of 10)
4 C/O -3 A Res.
Number and type of contacts - Thermal current (Ith) Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac Catalog Number RXM4GB3JD RXM4GB3BD RXM4GB3ED RXM4GB3FD RXM4GB3B7 RXM4GB3E7 RXM4GB3F7 RXM4GB3P7 $ Price ea. 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50
Table 23.5:
Miniature relays with low level contacts, with LED (sold in lots of 10)
4 C/O -3 A Res.
Number and type of contacts - Thermal current (Ith) Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 240 Vac Catalog Number RXM4GB2JD RXM4GB2BD RXM4GB2ED RXM4GB2FD RXM4GB2B7 RXM4GB2E7 RXM4GB2F7 RXM4GB2P7 RXM4GB2U7 $ Price ea. 8.10 8.10 8.10 8.10 8.10 8.10 8.10 8.10 8.10
RXM
Refer to Catalog 8501CT0601
Table 23.7:
Without LED 12 Vdc 24 Vdc 48 Vdc 110 Vdc 220 Vdc 24 Vac 48 Vac 120 Vac 230 Vac With LED 24 Vdc 24 Vac 230 Vac RXM2AB2B7TQ RXM2AB2P7TQ RXM4AB2BDTQ RXM4AB2B7TQ RXM4AB2P7TQ RXM2AB1BDTQ RXM2AB1B7TQ RXM2AB1F7TQ RXM2AB1P7TQ RXM4AB1JDTQ RXM4AB1BDTQ RXM4AB1EDTQ RXM4AB1FDTQ RXM4AB1MDTQ RXM4AB1B7TQ RXM4AB1E7TQ RXM4AB1F7TQ RXM4AB1P7TQ
Table 23.8:
Miniature relays with LED without Push Button (sold in lots of 100)
Number and type of contacts - Thermal current (Ith) 2 C/O - 12 A Res. Coil Voltage 24 Vdc 24 Vac 230 Vac Catalog Number RXM2AB3BDTQ RXM2AB3B7TQ RXM2AB3P7TQ $ Price ea. 6.80 6.80 6.80 4 C/O - 8 A Res. Catalog Number RXM4AB3BDTQ RXM4AB3B7TQ RXM4AB3P7TQ $ Price ea. 7.50 7.50 7.50
Table 23.9:
a b c
RXM2a RXZE2M114b RXM4a RXM2 Box lug connector RXZE2M114Mb RXM4 RXZE2S108Mc RXM2 Separate Box lug connector RXM3 RXZE2S111Mb RXM4 RXZE2S114Mb When mounting relay RXM2 on socket RXZE2M, the thermal current must not exceed 10 A. Thermal current Ith: 10 A Thermal current lth: 12 A Mixed
Table 23.10:
RXZE2S114M with relay RXM4AB2F7TQ
Table 23.11:
Description
RXM041BN7
Clip-in markers
RXZ400
File CCN
IEC 61810-1
RoHS Compliant
CP1
Discount Schedule
23-3
23
Metal hold-down clip Plastic hold-down clip Bus jumper, 2-pole (Ith: 5 A) Mounting adapter for DIN rail Mounting adapter for mounting directly to a panel
RPM
Refer to Catalog 8501CT0601
www.schneider-electric.us
Zelio RPM plug-in relays and sockets provide a comprehensive selection of relays responding to the most demanding standards at 15 A. Some of the features include: Spring return test button for testing the contacts (standard) Green LED indication of relay status (depending on version) Mechanical indication of relay status (standard) Plug-in protection module to protect against electrical spikes Table 23.12: Power relays without LED (sold in lots of 10)
Number and type of contacts - Thermal current (Ith) 1 C/O - 15 A Res. 2 C/O - 15 A Res. Catalog Number RPM21JD RPM21BD RPM21ED RPM21FD RPM21B7 RPM21E7 RPM21F7 RPM21P7 $ Price ea. 7.10 7.10 7.10 7.10 7.10 7.10 7.10 7.10 3 C/O - 15 A Res. Catalog Number RPM31JD RPM31BD RPM31ED RPM31FD RPM31B7 RPM31E7 RPM31F7 RPM31P7 $ Price ea. 9.60 9.60 9.60 9.60 9.60 9.60 9.60 9.60 4 C/O - 15 A Res. Catalog Number RPM41JD RPM41BD RPM41ED RPM41FD RPM41B7 RPM41E7 RPM41F7 RPM41P7 $ Price ea. 11.90 11.90 11.90 11.90 11.90 11.90 11.90 11.90 Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac Catalog Number RPM11JD RPM11BD RPM11ED RPM11FD RPM11B7 RPM11E7 RPM11F7 RPM11P7 $ Price ea. 5.40 5.40 5.40 5.40 5.40 5.40 5.40 5.40
RPM22F7
Table 23.13:
RPM32F7
Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac
Catalog Number RPM12JD RPM12BD RPM12ED RPM12FD RPM12B7 RPM12E7 RPM12F7 RPM12P7
$ Price ea. 6.30 6.30 6.30 6.30 6.30 6.30 6.30 6.30
Table 23.14:
Power relays with LED without Push Button (sold in lots of 10)
Number and type of contacts - Thermal current (Ith) 1 C/O - 15 A Res. 2 C/O - 15 A Res. Catalog Number RPM23JD RPM23BD RPM23ED RPM23FD RPM23B7 RPM23E7 RPM23F7 RPM23P7 $ Price ea. 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 3 C/O - 15 A Res. Catalog Number RPM33JD RPM33BD RPM33ED RPM33FD RPM33B7 RPM33E7 RPM33F7 RPM33P7 $ Price ea. 9.90 9.90 9.90 9.90 9.90 9.90 9.90 9.90 4 C/O - 15 A Res. Catalog Number RPM43JD RPM43BD RPM43ED RPM43FD RPM43B7 RPM43E7 RPM43F7 RPM43P7 $ Price ea. 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00
Coil Voltage 12 Vdc 24 Vdc 48 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac
Catalog Number RPM13JD RPM13BD RPM13ED RPM13FD RPM13B7 RPM13E7 RPM13F7 RPM13P7
$ Price ea. 5.90 5.90 5.90 5.90 5.90 5.90 5.90 5.90
23
RELAYS AND TIMERS RPZF2 + relay RPM22F7
File CCN
Table 23.15:
Mixed
IEC 61810-1
23-4
CP1
Discount Schedule
RPM
Refer to Catalog 8501CT0601
Table 23.16:
Description Diode
Protection modules
Voltage 6250 Vdc For use with RPZF1 RPZF2 RPZF3 RPZF4 RPZF1 RPZF2 RPZF1 RPZF2 RPZF3 RPZF4 RPZF1 RPZF2 RPZF1 RPZF2 RPZF1 RPZF2 RPZF3 RPZF4 RPZF3 RPZF4 Sold in lots of 20 10 20 20 10 20 20 20 10 10 Catalog Number RXM040W RUW240BD RXM041BN7 RXM041FU7 RUW241P7 RXM021RB RXM021BN RXM021FP RUW242B7 RUW242P7 $ Price ea. 2.30 2.60 2.30 2.60 2.60 2.30 2.30 2.30 3.20 3.20
RXM041BN7
2460 Vac RC circuit 110240 Vac
624 Vac/Vdc 2460 Vac/Vdc Varistor 110240 Vac/Vdc 24 Vac/Vdc 240 Vac/Vdc
Table 23.17:
Description Voltage Socket Type On-delay timer, interval timer, repeat cycle timer/starting on-delay, RPZF3 repeat cycle timer/starting off-delay, 24240 Vac/Vdc RPZF4 off-delay timer, one-shot timer, timing on de-energization, on-delay timer a See timer module description (selection of functions and time delays) in catalog 8501CT0601.
RUW101MW
56.00
Table 23.18:
RPZ1DA
Mounting adapters for mounting directly to a panel Clip-in markers (sheet of 108 markers) b Test button becomes inaccessible
RPZ3FA
CP1
Discount Schedule
23-5
23
RUM
Refer to Catalog 8501CT0601
www.schneider-electric.us
Zelio RUM plug-in relays and sockets provide a comprehensive selection of relays responding to the most demanding standards at 10 A. Some of the features include: Spring return test button for testing the contacts (standard) Green LED indication of relay status (depending on version) Mechanical indication of relay status (standard) Plug-in protection module to protect against electrical spikes Plug-in jumper bars for coil terminals to avoid time-consuming wiring Table 23.19:
Pins
RUMC2AB1BD
Cylindrical
Flat
Table 23.20:
Pins
Cylindrical
23
Flat
Table 23.21:
Pins
Relays for standard applications, with LED without Push Button (sold in lots of 10)
Number and type of contacts - Thermal current (Ith) Coil Voltage 2 C/O -16 A Res. Catalog Number 12 Vdc 24 Vdc 48 Vdc 60 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac RUMC2AB3JD RUMC2AB3BD RUMC2AB3ED RUMC2AB3FD RUMC2AB3B7 RUMC2AB3E7 RUMC2AB3F7 RUMC2AB3P7 RUMF2AB3JD RUMF2AB3BD RUMF2AB3ED RUMF2AB3FD RUMF2AB3B7 RUMF2AB3E7 RUMF2AB3F7 RUMF2AB3P7 $ Price ea. 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 12.40 4 C/O -16 A Res. Catalog Number RUMC3AB3JD RUMC3AB3BD RUMC3AB3ED RUMC3AB3ND RUMC3AB3FD RUMC3AB3GD RUMC3AB3B7 RUMC3AB3E7 RUMC3AB3F7 RUMC3AB3P7 RUMF3AB3JD RUMF3AB3BD RUMF3AB3ED RUMF3AB3FD RUMF3AB3GD RUMF3AB3B7 RUMF3AB3E7 RUMF3AB3F7 RUMF3AB3P7 $ Price ea. 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90 13.90
Cylindrical
Flat
IEC 61810-1
23-6
CP1
Discount Schedule
RUM
Refer to Catalog 8501CT0601
Table 23.22:
Mixed a
Relay type Catalog Number RUMC2 RUZC2M RUMC3 RUZC3M RUMC2 RUZSC2M Box lug connector RUMC3 RUZSC3M Separate b RUMF2 RUZSF3M RUMF3 a The inputs are mixed with the relay coil terminals, with the outputs located on the opposite side of the socket. b The inputs and outputs are separated from the relay coil terminals.
Table 23.23:
Description Diode RC circuit Varistor
All sockets
RUW241P7
Table 23.24:
RUW101MW
Description For use with Voltage On-delay timer, interval timer, repeat cycle timer/starting on-delay, repeat cycle timer/starting off-delay, All sockets 24240 Vac/Vdc off-delay timer, one-shot timer, timing on de-energization, on-delay timer. c See timer module description (selection of functions and time delays) in catalog 8501CT0601.
RUW101MW
56.00
Table 23.25:
RUZS2
Description Metal hold-down clip Bus jumper, 2-pole (Ith: 5 A) Clip-in markers
RPF Zelio plug-in power relays respond to the most demanding standards at 30 A. Some of the features include: Output contactsfour or six flat pins Coil terminalstwo flat pins Locating slot for mounting on DIN rail Two mounting holes for panel mounting Table 23.26:
Coil Voltage
RPF2AJD
Catalog Number 12 Vdc RPF2AJD 24 Vdc RPF2ABD 110 Vdc RPF2AFD 24 Vac RPF2AB7 120 Vac RPF2AF7 230 Vac RPF2AP7 a 30 A when mounted with 13 mm gap between two relays. 25 A when mounted side by side without a gap.
IEC 61810-1
CP1
Discount Schedule
23-7
23
RSB
www.schneider-electric.us
Zelio RSB plug-in relays and sockets provide a comprehensive selection of relays responding to the most demanding standards at 8 A, 12 A, and 16 A. Some of the features include: Plug-in protection module available to protect against electrical spikes Socket or printed circuit board installation Table 23.27: Relays for standard applications (sold in lots of 10)
Number and type of contacts - Thermal current (Ith) Coil Voltage 1 C/O -12 A Res. 1 C/O -16 A Res. 2 C/O -8 A Res. $ Price ea. 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 Catalog Numbera $ Price ea. Catalog Numbera $ Price ea. Catalog Numbera 6 Vdc RSB1A120RD 4.20 RSB1A160RD 5.00 RSB2A080RD 12 Vdc RSB1A120JD 4.20 RSB1A160JD 5.00 RSB2A080JD 24 Vdc RSB1A120BD 4.20 RSB1A160BD 5.00 RSB2A080BD 48 Vdc RSB1A120ED 4.20 RSB1A160ED 5.00 RSB2A080ED 60 Vdc RSB1A120ND 4.20 RSB1A160ND 5.00 RSB2A080ND 110 Vdc RSB1A120FD 4.20 RSB1A160FD 5.00 RSB2A080FD 24 Vac RSB1A120B7 4.20 RSB1A160B7 5.00 RSB2A080B7 48 Vac RSB1A120E7 4.20 RSB1A160E7 5.00 RSB2A080E7 120 Vac RSB1A120F7 4.20 RSB1A160F7 5.00 RSB2A080F7 220 Vac RSB1A120M7 4.20 RSB1A160M7 5.00 RSB2A080M7 230 Vac RSB1A120P7 4.20 RSB1A160P7 5.00 RSB2A080P7 240 Vac RSB1A120U7 4.20 RSB1A160U7 5.00 RSB2A080U7 a To order a relay complete with socket (sold in lots of 20): add suffix S to the catalog numbers selected above. Example: RSB 2A080RD + RSZ E1S48M becomes RSB 2A080RDS.
Table 23.28:
Relay type RSB1A120 Separate Box lug connector RSB1A160b RSB2A080 b When using the relay with socket RSZ E1S48M, terminals must be jumpered.
Table 23.29:
RSB2A080BD + RSZE1S48M
Description Diode RC circuit Diode + green LED
All sockets
23
Table 23.30:
RELAYS AND TIMERS
RZM modules are RoHS compliant as of date code 0610. For mounting track, see page 24-16.
23-8
CP1
Discount Schedule
Type K
Class 8501 / Refer to Catalog 8501CT0301
Table 23.31:
Table 23.32:
Table 23.35:
None Available
KL12b
45.00
DC
DPDT
None Available
KLD12b
45.00 AC 50/60 Hz
DPDT DPDT
Table 23.33:
Type 6
Voltage V35 V36 V14 V20 V24 Voltage Codes V50 V51 V53 V56 V60 V63 Codes KP12 S S S S S KPD12 S S S S S KP12P14 S S S S KPD12P14 S S S S KP13 S S S S KPD13 S S S S S KP13P14 S S S KPD13P14 S KU12 S S S S KUD12 S KU12M1 KUD12M1 S KU12P14 S S KUD12P14 S KU12M1P14 S S KUD12M1P14 S KU13 S S S S KUD13 S S S KU13M1 KUD13M1 KU13P14 S S KUD13P14 KU13M1P14 S S S KUD13M1P14 S S KF12 S S S KFD12 S S KF13 S S KFD13 S KL12 S S KLD12 S S Note: S = Stocked. Factory order items require a minimum order quantity of 25 and have a lead time of 12 weeks. b Voltage code must be specified to order this product. Refer to standard voltage codes listed in Table 23.33 and insert as shown in Table 23.37: How to Order.
DC
Table 23.36:
Resistive 75% PF DC Resistive Type Continuous Hp Volts Amperes Amperes 120 12 1/3 KP 28 12 240 12 1/2 120 12 1/3 KU 28 12 KF 240 12 1/2 120 12 1/3 KL 28 12 240 12 1/2 Note: All 8501 K relays have a B300 rating. c 3 pole devices have a 20 A max. total (sum of currents in all 3 poles), continuous rating. d 3 pole devices have a 30 A max. total (sum of currents in all 3 poles), continuous rating. e Socket is not required with Type KF relays. AC Volts
Table 23.37:
How to Order
Catalog Number Class 8501 Type KP12 Voltage Code V20
To Order Specify: Class Number Type Number Voltage Code (See Stocked Relay Table above)
For sockets and accessories, see page 23-13. For track, see page 24-16.
CP2
Discount Schedule
23-9
23
3PDT
24.60
8501KA
Refer to Catalog 8501CT9401
www.schneider-electric.us
8501KA alternating relay is designed to minimize pump and motor wear by equalizing run time between parallel components in a multi-pump system. The relay is controlled by an external control switch. The switch may be any type of contact closure; for example the contacts of a timing relay or the closure of a float switch. The 8501KA relay also has a toggle switch that allows the operator to lock one side of the duplex system in the on position.
12 amp Resistive Rating SPDT or DPDT Toggle switch for load control LED Load Indicators
Table 23.38:
AC & DC
DPDT (N.O.)
LED + Toggle
8501KA112A
95.00
Table 23.39:
Type Voltage Code 8501KA81 8501KA82 8501KA112 8501KA112A
Relay Availability
AC & DC Voltage 12 V36 24 V14 120 V20 S S S S AC Voltage 240 V24 Note: AC Voltage is 50/60 Hz S items have a 2 week lead time and no minimum order requirement. All other part numbers require a minimum order quantity of 100 and have a lead-time of 18 weeks.
Table 23.40:
Type
Contact Ratings
AC AC Volts 120 240 Resistive Amperes 12 12 HP 1/3 1/2 Pilot Duty B300 DC Volts 30 DC Resistive Amperes 12
8501KA81
Table 23.41:
Diagram A, C & D
Alternating Functions
Toggle Switch Position Detail S1 = Control Switch 1 S2 = Control Switch 2 LA = Load 1 LB = Load 2 Alternate Closing S1 alternates the loads between LA and LB. Lock 1 LA is ON and LB is OFF. S1 is not used in this mode. Lock 2 LA is OFF and LB is ON. S1 is not used in this mode. Alternate Closing S1 alternates the loads between LA an dLB. S2 will only control LA. Lock 1 S1 will control LA and S2 will control LB Lock 2 S1 will control LB and S2 will control LA. The cross wired option allows extra system load capacity through simultaneous operation of both motors when needed (LA and LB energize simultaneously when both S1 and S2 are closedrelay contacts are not isolated) Input voltage must applied at all times for proper alternation. Use of a solid state control switch for S1 or S2 may not initiate alternation corredtly. S1 or S2 voltage must be from the same supply as the units input voltage (see wiring diagrams). Loss of input voltage resets the unit; LA becomes the lead load for the next operation.
23
RELAYS AND TIMERS
ALL
8501KA81
8501KA112
B.
D.
8501KA82
8501KA112A
Approvals
File Class E78351 NLDX E78351 NLDX2 File Class 242675 3211-07 IEC 61810-1
23-10
CP2
Discount Schedule
Type R
Class 8501 / Refer to Catalog 8501CT0301
Table 23.44:
Table 23.42:
Type 8501RS41 a 8501RSD41a 8501RS42a 8501RSD42a 8501RS43a 8501RSD43a 8501RS44a 8501RSD44a a
Manual operator/ green LED pilot light options Silver tin oxide contacts
Table 23.45:
Table 23.46:
Table 23.43:
Type
Manual Operator and Pilot Light None DC Manual Operator Pilot Light
RSD44M1P14b 54.50 Manual Operator and Pilot Light Voltage code must be specified to order this product. Refer to standard voltage codes listed in Table 23.43 and insert as shown in Table 23.49: How to Order.
Table 23.48:
Class 8501 Type Operating Data
Application Data
Pick-Up Time Drop-Out Time Operating Temperature Duty Cycle Voltage Range AC CoilsInrush AC CoilsSealed DC Coils File CCN File Class RS41 RSD41 20 ms Maximum RS42 RSD42 RS43 25 ms Maximum 20 ms Maximum RSD43 RS44 RSD44 20 ms Maximum
-40oC to +70oC (-40oF to +158oF) Continuous AC coils +10%, -15% of nominal DC coils +10%, -20% of nominal Coil 9 VA 6.2 VA 1.5 VA 1.2 VA 0.9 watts 0.9 watts E78351 UR NLDX2, NLDX8 211268 CSA 3218 07 CE marked yes RoHS Compliant yes File E78351c UL Listed CCN NLDX, NLDX7 c When used with the appropriate 8501NR socket.
10.3 VA 1.7 VA
1.4 watts
11.9 VA 2.1 VA
1.5 watts
Table 23.49:
For sockets and accessories, see page 23-13. For track, see page 24-16. To Order Specify:
How to Order
Catalog Number Class 8501 Type RS42 Voltage Code V20
CP2
Discount Schedule
23-11
23
Voltage Code V35 V36 V14 V20 V24 Voltage Code V50 V51 V53 V60 RS41 S S RSD41 S S RS41M1 RSD41M1 RS41P14 S S RSD41P14 S RS41M1P14 S S RSD41M1P14 S RS42 S S S S RSD42 S S RS42M1 RSD42M1 RS42P14 S S RSD42P14 S S RS42M1P14 S RSD42M1P14 S RS43 S S RSD43 S RS43M1 RSD43M1 RS43P14 S RSD43P14 RS43M1P14 S RSD43M1P14 RS44 S S S RSD44 S S RS44M1 RSD44M1 RS44P14 S RSD44P14 S RS44M1P14 S RSD44M1P14 Note: S = Stocked. Factory order items require a minimum order quantity of 25 and have a lead time of 12 weeks.
Table 23.47:
Type R
Class 8501 / Refer to Catalog 8501CT0301
www.schneider-electric.us
Table 23.50:
8501RS14M1V14
Input 5A Options Voltage None For Manual Operator AC switching 50/60 Pilot Light inductive Hz loads Manual Operator and Pilot Light None Manual Operator Contacts: Silver Tin DC Pilot Light Oxide Manual Operator and Pilot Light
Continuous Horsepower Current Rating Rating 120/240 Vac 3 1/10 RS4 c RSD4c 30 Vdc 3 120/240 Vac 5 1/6 RS14c RSD14c 28 Vdc 5 120/240 Vac 1 1/16 (2.8 FLA) RS24 RSD24 30 Vdc 1 120/240 Vac 5 RS34 RSD34 30 Vdc 5 c RS4/RSD4, RS14/RSD14 have NEMA C300 pilot duty rating.
Table 23.55:
Type Voltage Code RS4 RS4M1 RS4P14 RS4M1P14 RS14 RS14M1 RS14P14 RS14M1P14 RS24 RS34
Table 23.51:
3A
3 A Version
Type RS4a RS4M1a RS4P14a RS4M1P14a RSD4a RSD4M1a RSD4P14a RSD4M1P14a $ Price 32.70 35.00 40.90 43.10 28.70 30.80 36.80 39.00
8501RSD34V51
Input Options Voltage None Manual Operator AC For low level 50/60 Pilot Light switching Hz Manual Operator and Pilot Light None Contacts: Manual Operator Fine Silver DC Pilot Light (Gold Flashed) Manual Operator and Pilot Light
Table 23.56:
Type
23
RELAYS AND TIMERS
Table 23.52:
1 A Version
Input Voltage AC 50/60 Hz DC Type RS24a RSD24a $ Price 53.00 53.00
Table 23.53:
5 A, Hermetically Sealed Input Voltage Type $ Price 5 Ampere Resistiveb AC 50/60 Hz RS34a 53.00 Silver Tin Oxide Contacts Suitable for Class I DC RSD34a 53.00 Division 2 Locations a Voltage code must be specified to order this product. Refer to standard voltage codes shown in Table 23.55. b Do not ground the frame.
Voltage Code V50 V51 V53 V56 V60 RSD4 S S RSD4M1 RSD4P14 S RSD4M1P14 S RSD14 S S S RSD14M1 S RSD14P14 S S S RSD14M1P14 S S RSD24 S RSD34 S S Note: S = Stocked. Factory Order items require a minimum order quantity of 25 and have a lead time of 12 weeks.
Table 23.57:
Application Data
Class 8501 Type RS4 RSD4 RS14 RSD14 RS24 RSD24 RS34 RSD34 Pick-Up Time 20 ms Maximum 13 ms Max. Operating Drop-Out Time 20 ms Maximum 6 ms Max. Data Operating Temperature -40oC to +70oC (-40oF to +158oF) -40oC to +70oC (-40oF to +158oF) Range Duty Cycle Continuous Voltage Range AC coils +10%, -15% of nominal and DC coils +10%, -20% of nominal Coil AC CoilsSealed 1.2 VA 1.2 VA 1.2 VA 1.2 VA AC CoilsInrush 6.2 VA 6.2 VA 6.2 VA 6.0 VA DC Coils 0.9 watt 0.9 watt 0.9 watt 0.9 watt UR File: E197072 CCN: NRNT2 N/A C UR US File: E197072 CCN: NRNT8 (Approved but not marked) File: E196809 CCN: NQMJ2, NQMJ8 CSA File: 211268 Class: 3218 07 File: 211268 Class: 3218 06 Approvals CE marked Yes RoHS Compliant Yes UL Listed File E78351 CCN NLDX, NLDX7d d When used with the appropriate 8501 NR Socket. For sockets and accessories, see page 23-13. For track, see page 24-16.
23-12
CP2
Discount Schedule
Type N
Class 8501 / Refer to Catalog 8501CT0301
Square D Sockets
8501NR sockets are designed for use with plug-in Class 8501 Type K, KA, and R relays, 8430MPS phase failure relays and 9050JCK timers. The 8501NR45 screw terminal sockets have pressure wire clamps that accept 1 or 2 #1622 wires. All other sockets have pressure clamps that will accept 1 or 2 #1222 wires. The recommended tightening torque for all terminals is 7-8 lb-in. All devices stocked in central warehouse DIN track mount or direct panel mount Tubular sockets available in easy-to-wire single tier or double tier versions RoHS compliant Table 23.58:
8501 Type KP12 KPD12 KA81 KA82
8501NR51
8501NR61
Snapmount Sockets
Socket Rating Description UL CSA 300 V, 10 A Type NR51 NR51B NR52c NR52Bc 9050 Type JCK1119 JCK3139 JCK5159 JCK60 JCK1 F JCK3 F JCK5 F JCK2129 JCK4149 JCK70 JCK2F JCK4F $ Price Std. ea. Qty.a 12.30 10.20 12.30 10.20 18.50 16.50 18.50 16.50 20.60 18.50 28.70 26.70 28.70 26.70 26.70 26.70 28.70 26.70 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 10
8501NR52
8501NR62
600 V, 10 A 8 Pin Tubular Single Tier Screw Terminal 300 V, 15 A 600 V, 5 A 8 Pin Tubular Double Tier Screw Terminal 300 V, 16 A
300 V, 10 A
8501NR82
8501NR45
600 V, 5 A NR61 11 Pin Tubular Single Tier Screw Terminal 300 V, 15 A 300 V, 10 A NR61B 600 V, 5 A NR62c 11 Pin Tubular Double Tier Screw Terminal 300 V, 16 A 300 V, 10 A NR62Bc NR82 11 Pin Spade 300 V, 15 A 300 V, 15 Ab Double Tier Screw Terminal NR82B NR41c 5 Pin Spade Double Tier Screw Terminal 300 V, 15 A 300 V, 15 A NR41Bc NR42 8 Pin Spade Double Tier Screw Terminal 300 V, 10 A 300 V, 10 A NR42B NR43 11 Pin Spade Double Tier Screw Terminal 300 V, 10 A 300 V, 10 A NR43B NR34 14 Pin Spade Double Tier Screw Terminal 300 V, 10 A 300 V, 10 A NR34B
8501NR41
8501NR42
RS4 RSD4 NR45 28.70 1 RS14 RSD14 14 Pin Spade 300 V, 10 A 300 V, 10 A RS24 Double Tier Screw Terminal RSD24 NR45B 26.70 10 RS34 RSD34 a Must be ordered in multiples of the quantity listed. Units provided in standard quantity of one are individually packaged; devices with B suffix have a standard quantity of 10 per bulk pack. b Rated for use with Class 8430 Type MPS at 480 Volts. Rated 10 A at 300 volts by CSA. c Finger Safe
For DIN 3 mounting track and end clamps, see page 24-16, or refer to: NEMA Style terminal block section of catalog 9080CT9601 IEC Style terminal block section of catalog 9080CT9901 Table 23.59:
Socket
Socket Accessories
Description Type NH51 NH7 NH7 NH52 NH7 NH7 NH61 NH7 NH52 NH7 NH82 NH7 Supplied with socket as standard 8501NH42 8501NH42 8501NH42 8501NH45 $ Price ea. Std. Pack d 1.00 8.30 8.30 1.00 8.30 8.30 1.00 8.30 1.00 8.30 1.00 8.30 1.00 1.00 1.00 1.00 10 1 1 10 1 1 10 1 10 1 10 1 10 10 10 10
8501NR34
8501NR43
How to Order
To Order Specify: Catalog Number Class 8501 Type NR51B
Approvals:
File CCN E66924 SW1V2 File Class 211268 3211 07 IEC61810-1 RoHS Compliant as of date code 0639
CP2
Discount Schedule
23-13
23
8501NH7
8501KP12, KPD12 Hold Down Clip 8501NR51 8430MPSV24 Hold Down Spring 9050JCK Hold Down Spring 8501KP12, KPD12 Hold Down Clip 8501NR52 8430MPSV24 Hold Down Spring 9050JCK Hold Down Spring 8501KP13, KPD13 Hold Down Clip 8501NR61 9050JCK Hold Down Spring 8501KP13, KPD13 Hold Down Clip 8501NR62 9050JCK Hold Down Spring 8501KU and KL Hold Down Clip 8501NR82 8430MPSV29 Hold Down Spring 8501NR41 8501RS41, RSD41 Hold Down Clip 8501NR42 8501RS42, RSD42 Hold Down Clip 8501NR43 8501RS43, RSD43 Hold Down Clip 8501NR34 8501RS44, RSD44 Hold Down Clip 8501RS4, RSD4 8501NR45 8501RS14, RSD14 Hold Down Clip 8501RS24, RSD24 8501RS34, RSD34 d Must be ordered in multiples of the quantity listed.
Type C
Class 8501 / Refer to Catalog 8501CT0301
www.schneider-electric.us
8501CDO6V51
Table 23.60:
Contact Arrangement
AC Rated Contacts SPST 1 0 CO6a 32.70 CDO6a 32.70 600 30 10 2 2 2 10 VA DPST 2 0 CO7a 51.30 CDO7a 51.30 600 30 5 1 1 1 10 VA SPST 0 1 CO8a 32.70 CDO8a 32.70 600 30 10 2 2 2 10 VA SPDT 1 1 CO15a 57.30 CDO15a 57.30 600 30 5 1 1 1 10 VA DPDT 2 2 CO16a 69.60 CDO16a 69.60 600 30 5 1 1 1 10 VA DC Rated Contacts 110 V 220 V SPST 1 0 CO21a 71.70 CDO21a 71.70 500 20 8 10 VA N.A. DPDT 2 2 CO22a 84.00 CDO22a 84.00 325 10 4 10 VA a Voltage codes must be specified to order this product. Refer to standard voltage codes listed in Table 23.63 and insert as shown in Table 23.65: How to Order.
Table 23.61:
Operating Data
AC 6 through 480 volts, + 10/-15% of nominal at 25 oC DC 6 through 110 volts, + 10/-20% of nominal at 25 oC 15 VA Duty: Continuous rated coils. (Non-replaceable) AC: -22 oF to +122 oF (-30 oC to +50 oC) DC: -22 oF to +140 oF (-30 oC to +60 oC)
Table 23.63:
Class 8501 Type 6
Operating Voltages/ Voltage Range Coil Inrush (Vac Coil) Coils Operating Temp. Range
Approvals:
File E78351 CCN NLDX File 218139 Class 3211 04
IEC 60947-4-1
Approximate Dimensions
A D C
Voltage Voltage V35 V36 V14 V20 V08 V24 V04 V29 V50 V51 V53 V60 Code Code CO6 S S S S S S S CDO6 S S CO7 S S S S S S S CDO7 S S CO8 S S S S S CDO8 CO15 S S S S S S CDO15 S CO16 S S S S S S S CDO16 S S S CO21 S CDO21 S S CO22 S CDO22 S S Note: S = Stocked. Factory order items require a minimum order quantity of 25 and have a lead time of 12 weeks.
23
RELAYS AND TIMERS
Enclosure
NEMA 1 sheet steel enclosure Table 23.64:
B E
Type UE1
Class 9991
$ Price 19.70
Table 23.62:
Catalog Number 8501 CO6, CO7, CO8, CDO6, CDO7, CDO8 CO15, CO21, CDO15, CDO21 CO16,CDO16 CO22, CDO22
Dimensions
A in. mm in. B mm in. C mm 8.0 8.0 8.0 8.0 in. D mm in. E mm in. F mm 9.5 9.5 9.5 9.5
9991UE1
2.43 61.7 2.50 63.5 0.31 2.43 61.7 2.50 63.5 0.31 3.12 79.2 2.50 63.5 0.31 3.12 79.2 2.50 63.5 0.31
0.81 20.6 2.25 57.2 0.37 0.81 20.6 2.18 55.4 0.37 1.5 1.5 38.1 2.31 58.7 0.37 38.1 2.53 64.3 0.37
Table 23.65:
How to Order
Catalog Number Class 8501 Type CO6 Voltage Code V20
To Order Specify: Class Number Type Number Voltage Code (See Stocked Relay Table above)
23-14
CP2
Discount Schedule
Industrial Relays
www.schneider-electric.us
CAD
Refer to Catalog 8501CT0101
Terminal Type
Number of Contacts
5 5 5 5
5 3 5 3 5 3
0 2 0 2 0 2
Add the proper voltage code from Table 23.69 to the end of catalog number (for example, CAD50B7).
Table 23.67:
Number of Contacts
CAD503
b c
Table 23.68:
Approvals:
File CCN E164353 NKCR Number of Contacts
Instantaneous Auxiliary Contacts with Dust and Damp Protected Contacts (for use in particularly harsh industrial environments)
Contact Composition
Catalog Number
$ Price
Sealed d Normal 2 2 1 2 2 2 2 2 4e 1 2 1 1 Grounding terminal points (2 terminals jumpered together; see diagram on page 8 of Catalog 8501CT0101). Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils.
Table 23.69:
AC 50/60 Hz Coil (for additional voltage code options see page 7 of Catalog 8501CT0101). Volts 12 24 48 120 208 240 277 Code J7 B7 E7 G7 LE7 U7 W7 DC Coil (coils have built in suppression as standard) Volts 12 24 36 48 60 72 110 Code JD BD CD ED ND SD FD DC Low Consumption Coil (coils have built in suppression as standard) Volts 5 12 24 48 72 Code AL JL BL EL SL f Add the proper voltage code to the end of catalog number.
For replacement AC coils, see page 18-16. DC coils are not replaceable.
I12
Discount Schedule
23-15
23
CAD323
2 0 1 1 0 2 1 2 0 2 Spring Terminal 1 1 0 2 2 0 1 Not for Screw Clamp 1 1 DC devices 0 2 4 0 3 1 Screw Clamp 2 2 1 3 0 4 4b 1 4 0 3 1 Spring Terminal 2 2 1 3 0 4 Screw Clamp 2c 2c 4b 1 Spring Terminal 2c 2c Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils. Includes 1 N.O. and 1 N.C. overlapping contact. Screw Clamp
CAD
Refer to Catalog 8501CT0101
www.schneider-electric.us
Catalog Number LADT0 LADT2 LADT4 LADS2 LADT03 LADT23 LADT43 LADS23 LADR0 LADR2 LADR4 LADR03 LADR23 LADR43
$ Price 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00 131.00
LADT
Screw Clamp Off-Delay
Spring Terminal (Lockout Cover, See page 7 of Catalog 8501CT0101.) a With extended scale from 0.1 to 0.6 s. b With switching time of 40 ms 15 ms between opening of the N.C. contact and closing of the N.O. contact.
Table 23.71:
LA6DK
d e
LA6DK10 ed 77.00 LAD6K10 e 77.00 Power should not be simultaneously applied or maintained to the mechanical latching block and the CAD relay. The duration of the control signal to the mechanical latching block and the CAD relay should be 100 ms. Repair part for the preceeding version (non-TeSys) of this product. Not for use on CAD devices. Complete the catalog number by adding coil voltage code from Table 23.73. (for example, LA6DK10B)
Table 23.72:
These modules clip onto the right hand side of the control relay and the electrical connection is instantly made. Adding an input module is still possible.
RC Circuits (Resistor-Capacitor)
Effective protection for circuits highly sensitive to high frequency interference. Voltage limited to 3 Uc maximum and oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times the normal time).
CAD (Vac) Operational Voltage 24 to 48 Vac 110 to 240 Vac Catalog Number LAD4RCE LAD4RCU $ Price 26.20 26.20
23
LAD4
Protection provided by limiting the transient voltage value to 2 Uc maximum. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time).
24 to 48 Vac 50 to 127 Vac 110 to 250 Vac LAD4VE LAD4VG LAD4VU 26.20 26.20 26.20
CAD (Vac)
Protection provided by limiting the transient voltage value to 2 Uc maximum. Maximum reduction of transient voltage peaks.
24 Vac 72 Vac LAD4TB LAD4TS 26.20 26.20
CAD (Vac)
Table 23.73:
Voltage Voltage Code
c c1 c2 c3
1.77 45
c c1 c2 c3
1.77 45
in. (mm) CAD b c Without cover or add-on blocks With cover, without add-on blocks 32 50 3.03 (77) 3.31 (84) 3.39 (86) 323 503 3.90 (99) 3.31 (84) 3.39 (86) CAD b c Without cover or add-on blocks With cover, without add-on blocks 32 50
in. (mm) 323 503 3.90 (99) 3.66 (93) 3.74 (95)
23-16
I12
Discount Schedule
Industrial Relays
www.schneider-electric.us
CAD
Refer to Catalog 8501CT0101
Table 23.75:
Mounted using adaptor LAD4BB, to be ordered separately, see listing above. On-delay Type Operational Voltage Time Delay 0.1 to 2 s 24 to 250 Vac 1.5 to 30 s 25 to 500 s a For 24 V operation, the relay must be fitted with a 21 V coil (code Z7). Catalog Number LA4DT0U LA4DT2U LA4DT4U $ Price 82.00 82.00 82.00
Table 23.76:
For local override operation tests with two-position Auto-Man switch and O-I switch Mounted using adaptor LAD4BB, to be ordered separately, see listing above. Operational Voltage 24 to 100 Vac
$ Price 35.00
Table 23.77:
For Connection Description
For Marking Sheet of 64 self-adhesive blank labels 8 x 33 Sheet of 112 self-adhesive blank labels 8 x 12 For Protection Lockout cover Relay cover preventing access to the moving contact carrier
CAD, LAD (4 contacts), LA6DK LAD (2 contacts), LADT LADT, LADR CAD
Table 23.78:
Application Data
Type CAD (Vac) 690 V 600 V 6 kV CAD (Vdc) 690 V 600 V 6 kV CAD (Vdc) Low Consumption Conforming to IEC 60947-1-1 Overvoltage category III and degree of pollution 3 Conforming to UL, CSA Conforming to IEC 60947-1-1 To IEC 536 and VDE 0106
600 V 6 kV
Rated Impulse Withstand Voltage (Uimp) Separation of Electrical Circuits Conforming to Standards Approvals Protective Treatment Degree of Protection
Reinforced insulation up to 400 V IEC 60947-1-1, N-F C 63-140, VDE 0660, BS 4794. EN 60947-5-15 UL: File: E164353 CCN: NKCR CSA: File: Class: 3211 03 LR43364 CE TH (Tropical Finish). See page 23 of Catalog 8501CT0101 for details. Front face protected against direct finger Protection against direct contact IP 2X finger contact
I12
Discount Schedule
23-17
23
690 V
Control Relays
NEMA A600, Q600 IEC AC15, DC13 Contact Configuration
Mounting on 35 mm DIN 3 track or 4 screw direct mounting. Screws in open ready-to-tighten position.
Control Circuit
Catalog Number a
$ Price
Supply
Consumption
CA2KN40
CA2KN403
4 0 CA2KN40 Screw clamp 3 1 CA2KN31 2 2 CA2KN22 4 0 CA2KN403 Spring Termination 3 1 CA2KN313 2 2 CA2KN223 AC 4.5 VA 4 0 CA2KN407 Faston 1 x 6.35 3 1 CA2KN317 or 2 x 2.8 2 2 CA2KN227 4 0 CA2KN405 Solder pins for printed circuit 3 1 CA2KN315 board 2 2 CA2KN225 4 0 CA3KN40 Screw clamp 3 1 CA3KN31 2 2 CA3KN22 4 0 CA3KN403 Spring Termination 3 1 CA3KN313 2 2 CA3KN223 DC 3W 4 0 CA3KN407 Faston 1 x 6.35 3 1 CA3KN317 or 2 x 2.8 2 2 CA3KN227 4 0 CA3KN405 Solder pins for printed circuit 3 1 CA3KN315 board 2 2 CA3KN225 Complete catalog number by adding proper voltage code from Table 23.81 or Table 23.82 (for example, CA2KN40G7).
35.50 35.50 35.50 35.50 35.50 35.50 35.50 35.50 35.50 35.50 35.50 35.50 49.20 49.20 49.20 49.20 49.20 49.20 49.20 49.20 49.20 49.20 49.20 49.20
Table 23.80:
Compatible with programmable controller outputs. LED indicator incorporated. Wide range coil (70 to 130% Uc), suppressor fitted as standard. Screw clamp
23
RELAYS AND TIMERS CA4KN405 CA3KN407
4 0 CA4KN40 3 1 CA4KN31 2 2 CA4KN22 4 0 CA4KN403 Spring Termination 3 1 CA4KN313 2 2 CA4KN223 DC 1.8 W 4 0 CA4KN407 Faston 1 x 6.35 3 1 CA4KN317 or 2 x 2.8 2 2 CA4KN227 4 0 CA4KN405 Solder pins for 3 1 CA4KN315 printed circuit board 2 2 CA4KN225 Complete catalog number by adding proper voltage code from Table 23.83 (for example, CA4KN40BW3).
Table 23.81:
Vac 50/60 Hz 12
Coil Voltage Codes for CA2K Control Relays (0.81.15 Uc) (0.851.1 Uc)
24 36 42 48 110 120 127 208 220/ 230 230 230/ 240 380/ 400 400 400/ 415 440 480 500 660/ 690 Y7
Voltage J7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 Q7 V7 N7 R7 T7 S7 Code Note: Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72. (Price Adder 9.50)
Table 23.82:
Vdc
Voltage Code JD ZD BD CD ED ND SD KD FD Note: Coil with integral suppression device available: add 3 to the code required. Example: JD3.
Table 23.83:
Vdc Voltage Code
Coil Voltage Codes for CA4K, Low Consumption Control Relays (Wide Range Coil: 0.71.3 Uc)
12 JW3 24 BW3 48 EW3 72 SW3
Approvals:
File CCN
164353 NKCR
23-18
I12
Discount Schedule
Industrial Relays
www.schneider-electric.us
LA1KN20
LA1KN40
Screw Clamp
Spring Termination
LA1KN403
LA1KN20 LA1KN02 LA1KN11 LA1KN40a LA1KN31a LA1KN22a LA1KN13a LA1KN04a LA1KN203 LA1KN113 LA1KN023 LA1KN403a LA1KN313a LA1KN223a LA1KN133a LA1KN043a LA1KN207 LA1KN027 LA1KN117 LA1KN407a LA1KN317a LA1KN227a LA1KN137a LA1KN047a
14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30 14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30 14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30
1.06
27
58
1.34
1.45
34
38
1.34
2.24
a b c
34
57
Not to be used on CA4KN relays. Clip-on front mounting, 1 block per control relay. Auxiliary contact module not suitable for safety circuits.
Table 23.85:
Approximate dimensions for CA2, CA3, CA4K control relays On panel
LA1-K 4x4
Relay output, with common point changeover contact Control voltage Maximum switching capacity Operating temperature Reset time
2.28 58
1.97 50
Table 23.86:
1.22 31
2.24 57
1.38 35 1.77 45
Table 23.87:
Description Marker holderg
100
LA9D90
1.97 50
1.77 45
A2
n AM1DP200 or AM1DE200 mounting rail35 mm DIN rail (see page 22-16 for additional DIN rail)
2.28
58
1.77
45
in. mm
Table 23.88:
C in. 2.22 2.60 mm 59 66 Product AM1DP200 AM1DE200
Environment
Conforming to Standards Approvals IEC 947, NF C 63-140, VDE 0660, BS 5424, CE UL, CSA, DEMKO, NEMKO, SEMKO, FI Protection against direct finger contact -58 to 176 oF (-50 to 80oC) -13 to 122 oF (-25 to 50oC) 6562 ft (2000 m)
Protective treatment Degree of protection Ambient air temperature Maximum operating altitude
Conforming to IEC 68 (DIN 50016) TC (Climateproof) Conforming to VDE 0106 Storage Operation Without derating
I12
Discount Schedule
23-19
23
10x1.3
AB1Rg 4 maximum per Strip of 10 identical numbers, 0 to 9 25 0.70 device Strip of 10 identical capital letters A to Z AB1Gg For AC and DC voltages 12 to 24 V (varistor) LA4KE1Bd LA4KE1Ed Clips onto front For AC and DC voltages 32 to 48 V (varistor) Suppressor of relay with For AC and DC voltages 50 to 129 V (varistor) LA4KE1FCd modules with locating device. For AC and DC voltages 130 to 250 V (varistor) 5 LA4KE1UG d 9.80 incorporated No tools LED indicator required for For DC voltages 12 to 24 V (diode + Zener diode) LA4KC1Be connection. For DC voltages 32 to 48 V (diode + Zener diode) LA4KC1Ee For AC voltages 220 to 250 V (RC) LA4KA1Uf d Protection by the limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1 to 1.5 times normal). e No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times normal). f Protection by limitation of the transient voltage to 3 Uc max. and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 times to twice normal). g See Clip-in Marker Strips in Catalog 8501CT0101 for information on completing the catalog number. Clip-on markersg
2.28 58
2.05 53
Voltage (V) Type Timing Range, s Composition C.O. AC or DC / 24 to 48 On-delay 1 to 30 1 AC / 110 to 240 Note: For other electronic timers see Type RE7 and 9050 Type JCK, pages 23-28 and 23-29.
$ Price
Industrial Relays
Miniature size saves space. Mounts on 35 mm DIN 3 track Up to 4 poles. Control Circuit Supply N.O. N.C. 1 1 AC 4.2 VA 2 0 Screw clamp 1 1 DC 2.2 W 2 0 Use the appropriate voltage code to complete the catalog number (for example: CA2SK11G7) Consumption Type of Termination Contact Configuration Catalog Number CA2SK11 a CA2SK20 a CA3SK11 a CA3SK20 a $ Price 43.70 51.00
CA2SK11G7
Table 23.90:
Type of Termination
Screw clamp
16.90
Dampens the voltage spike that may occur when the relay coil is de-energized. The spike may adversely affect solid state equipment near the relay. The transient suppressor module snaps into a cavity located in the side of the relay. These modules can be used with CA2SK and CA3SK relays. Table 23.91: Transient Suppressor Module
Catalog Number LA4SKEIE LA4SKEIU $ Price 21.80
Control Circuit Voltage 2448 Vac 50/60 Hz, 2448 Vdc 110250 Vac 50/60 Hz, 110250 Vdc
Table 23.92:
Voltage 12 24 36 48 72 110 120 220 50/60 Hz B7 b E7 b F7 G7 b M7 b DC JD BD CD ED SD b Alternating relays CA2SKE available in these voltages only. No other voltages are available.
2.20
56
23
RELAYS AND TIMERS CA2SKE20 Approvals:
File CCN E164353 NKCR File LR43364 Class 3211 03
Coil Voltage Type $ Price (Voltage-Hz) 2450/60 CA2SKE20a 120.00 Use the appropriate voltage code to complete the catalog number (for example, CAZSK11G7). Only available with voltages indicated above.
Table 23.94:
NEMA Rating
Make A 60 30 15 12 VA
A600
7200
720
10
10
1.06
27
2.19
56
.20
5
.16 (4)
#8 or 4mm
2.28 (58)
1.93 (49)
.14
4
Dual Dimensions:
INCHES Millimeters
1.77 (45)
2.68 (68)
1.36 (34.5)
23-20
I12
Discount Schedule
Type X Relays
Class 8501 / Refer to Catalog 8501CT9601 Table 23.99: AC Contact Ratings (for DC ratings, see page 23-22)
Inductive 35% Power Factor Type of Cartridge V Make NEMA Rating A VA Break A VA Resistive 75% Power Factor
AC Control Relays
Straight-through wiring Plug-in contact cartridges for easy contact conversion and replacement Contact conversion without removing terminal screws or wires Self-lifting pressure wire connectors Replaceable coil
Table 23.95:
AC Control Relays
Control Relay a
Typec $ Price 0 XO00 116.00 2 XO20 171.00 3 XO30 201.00 4 XO40 228.00 6 XO60 286.50 8 XO80 312.00 10 XO1000 399.00 12 XO1200 458.00 A maximum of 8 N.C. contacts is allowed on 912 pole relays.
60 6 3 A600 30 7200 1.5 720 10 10 15 12 1.2 cartridge above except Masterd A600 Same as standard the continuous ampere rating substitute 20 A for Logic Reed 150 Vac, 150 mA, 8 W Maximum d Maximum of six 8501 Type XC4 Master Cartridges may be used on only 7 and 8 pole AC Devices
AC Master Relays
20 ampere contact rating due to use of master contact cartridges. d Provisions for standard cartridges to be used in contact cavities not occupied by master cartridges in 2-8 pole AC relay.
Table 23.96:
AC Master Relays
Open Typeb $ Price 257.00 399.00 543.00
AC Timing Relays
Easily convertible On Delay or Off Delay Two adjustable timing ranges Repeat accuracy well above 10% Convertible 1 N.O. and 1 N.C. timed contacts Large knob for easy adjustment of time delay Off Delay mode times out even after loss of power.
3.50 89 3.12 79
Table 23.97:
Type XO40XTE1 Timing Relay
AC Timing Relays
Timing Relay 0.260 s Typec 5180 s Typec 513.00 570.00 629.00 513.00 570.00 629.00 $ Price
B30080-064 Prov. for (2) #8/#10 Mtg. Screws
0 2 4 0 2 4
1 1 1 1 1 1
1 1 1 1 1 1
XO00XTE1 XO00XTE2 XO20XTE1 XO20XTE2 XO40XTE1 XO40XTE2 XO00XTD1 XO00XTD2 XO20XTD1 XO20XTD2 XO40XTD1 XO40XTD2
AC Latching Relays
Table 23.98:
Type XO40XL Latching Relay
AC Latching Relays
Latching Relay Typec XO20XL XO30XL XO40XL XO60XL XO80XL $ Price 372.00 399.00 428.00 485.00 543.00
3.12 79
1.12 28
Millimeters
Voltage Code must be specified to order these products. Refer to Table 23.101 and insert the code as shown in Table 23.104: How to Order.
Approvals:
File Class
For replacement coils, see page 23-23. Table 23.104: How to Order
To Order Specify: Catalog Number Class 8501 Type XO40 Voltage Code V02
2009 Schneider Electric All Rights Reserved
CP1
Discount Schedule
23-21
23
Mechanical latch holds all contacts switched even after removal of power from replaceable latching coil. Provides sequence memory in the event of power loss. Ideal for press control, process control and punch presses. Replaceable unlatch coil to switch contacts back to original state.
.19 5
2.23 57
Timed N.O. Convertible Timing Convertible Mode Instantaneous Contacts Contacts N.O. N.C.
Type X Relays
Class 8501 / Refer to Catalog 8501CT9601
www.schneider-electric.us
DC Latching Relays
Replaceable, highly reliable pure DC power plant: no economizing resistors, overlapping contacts or dualwound coil. Utilizes the same Type XB adder decks and attachments as the AC version. Offers all the features of the AC relay. Available in up to 8 poles. All contact poles are usable since no overlapping contacts are needed.
Type XDO40 Control Relay
Type XDO40XDL Latching Relay
Mechanical latch holds all contacts switched even after removal of power from replaceable latching coil. Provides sequence memory in the event of power loss. Ideal for sequencing applications such as press control, process control and punch presses. Replaceable unlatch coil to switch contacts back to original state.
Latching Relay
3.12 79
24 68
3.56 90 3.12 79
DC Utility Relays
B30080-066 Prov. for (2) #8/#10 Mtg. Screws
DC Timing Relays
Ideal for utility plant applications where reliable performance and a pure DC power plant is required. In addition to the Type XDO relay features, the Type XUDO provides:
Type XDO40XTE2 Timing Relay
Easily convertible On Delay or Off Delay. Two adjustable timing ranges. Repeat accuracy well above 10%. Convertible 1 N.O. and 1 N.C. timed contacts. Large knob for easy adjustment of time delay. Off Delay mode times out even after loss of power.
Type XUDO40 Utility Relay
Up to 12 poles N.O. or N.C. Nominal 125 Vdc coil, capable of handling 140 Vdc continuously and picking up at 105 Vdc after having been operated at 140 Vdc continuously. Other voltages with comparable operating characteristics are available. Enclosed device capable of operating in 145F ambient.
23
RELAYS AND TIMERS
Timing Mode On Delay Off Delay
7.77 197
Timing Relay 0.260 s Type XDO00XTE1 e XDO20XTE1 e XDO40XTE1 e XDO00XTD1 e XDO20XTD1 e XDO40XTD1 e 5180 s Type XDO00XTE2 e XDO20XTE2 e XDO40XTE2 e XDO00XTD2 e XDO20XTD2 e XDO40XTD2 e $ Price 656.00 714.00 769.00 656.00 714.00 769.00
3.56 903.12 79
B30080-075 A
Voltage code must be specified to order these products. Refer to Table 23.113 and insert the appropriate code as shown in Table 23.114: How to Order.
For Replacement coils, see page 23-23 For UL and CSA approvals, see page 23-21
23-22
CP1
Discount Schedule
Type X Relays
Class 8501 / Refer to Catalog 8501CT9601
XLa XDLa
201.00 264.00
XJ1
10.70
XB20 XB40
57.00 116.00
XBR20 XBR11 XBR10 XBR01 XBR02 XC1 XC2 Form Y1591 Y1592 Y1593 Y1594
XC4
71.40
XA1
7.20
XS1
57.00
NEMA 1 EnclosureFormed from sheet steel to provide strength and rigidity. Two conduit knockouts are located in both the top and Class 9991 bottom of the enclosure. The enclosure is furnished with self tapping screws for mounting the relay inside the enclosure. Type Accommodates a single 4 or 8-pole AC or DC relay, 12-pole AC relay, 4-pole AC latching relay, and 4-pole AC timing relay. UE7 Note: The 4-pole DC latching relay, 4-pole DC timing relay, 8-pole AC and DC latching relays and 12-pole utility auxiliary relay will not fit. a See Mechanical Latch Attachment Voltage Codes table below:
99.00
DC
Device Type
110-115 120 V 208 V 220 V 240 V 277 V 380 V 440 V 480 V 550 V 600 V In-rush Sealed V 60 23 44 51 52 53 55 62 65 148 23 XO, AC 8501 9998 X b XMO 50 24 44 52 53 62 65 143 25 b To order an unlatch coil add the letter L to the type number and the letter B to the suffix number. Example: for a 120 V 60 Hz unlatch coil order a Class 9998 Type XL44B. c Not dual rated250 Vdc only d 125 Vdc only 24 V
74.70
CP1
Discount Schedule
23-23
23
RE11/RE48/REXL
Refer to Catalog 9050CT0001
www.schneider-electric.us
Table 23.119: RE11 Modular Timers17.9 mm wide (Multi-range timers offering 7 selectable ranges)
Functions Supply Voltages Rated Current Catalog Number $ Price Output 1 C/O contact On delay 24 Vdc, 24240 Vac 8A RE11RAMU 51.00 Interval 24 Vdc, 24240 Vac 8A RE11RHMU 51.00 Asymmetrical repeat cycle 24 Vdc, 24240 Vac 8A RE11RLMU 63.00 Asymmetrical repeat cycle 12 Vac/Vdc 8A RE11RLJU 89.00 One shot 24 Vdc, 24240 Vac 8A RE11RBMU 62.00 Off delay with control start 24 Vdc, 24240 Vac 8A RE11RCMU 62.00 Multi-function a 24 Vdc, 24240 Vac 8A RE11RMMU 74.00 Multi-function a 12240 Vac/Vdc 8A RE11RMMW 89.00 Multi-function a 12240 Vac/Vdc 8A RE11RMMWS 89.00 Multi-function a 12 Vac/Vdc 8A RE11RMJU 89.00 Multi-function b 24 Vdc, 24240 Vac 8A RE11RMEMU 89.00 Multi-function a 24 Vdc, 24240 Vac 8A RE11RMXMU 89.00 a Timing ranges: 0.11 s, 110 s, 0.110 min, 110 min, 0.11 hr, 110 hr, 10100 hr b Timing ranges: 0.11 s, 110 s, 0.110 min, 110 min, 0.11 hr, 110 hr IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC (CE marking) + Conforming to standards EMC directive (89/336/EEC + IEC 60669-2-3) cULus File: E173076 CNN: NRNT File: E173076 CNN: NRNT7 Approvals CSA File: 217698 Class 3211 07 CE GL except RE11 RMX MU and RE11 RME MU oF (oC) 22 to +140 (30 to +60) Ambient air temperature around the Storage device Operation oF (oC) 4 to +140 (20 to +60)
RE11RLMU
Table 23.120: RE11 Modular Timers17.9 mm wide (Multi-function, dual function or single function)
Functions Supply Voltages Rated Current 0.7A 0.7A 0.7A 0.7A 0.7A Catalog Number RE11LAMW RE11LHBM RE11LCBM RE11LLBM RE11LMBM $ Price 54.00 51.00 62.00 89.00 74.00 Solid state output On delay 24240 Vac/Vdc Interval 24240 Vac Off delay with control contact 24240 Vac Asymmetrical repeat cycle 24240 Vac Multi-function 24240 Vac Timing ranges: 0.11 s, 110 s, 0.110 min, 110 min, 0.11 hr, 110 hr, 10100 hr Conforming to standards
RE11LHBM
IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC (CE marking) + EMC directive (89/336/EEC + IEC 60669-2-3) cULus File: E173076 CNN: NRNT File: E173076 CNN: NRNT7 CSA File: 217698 Class: 3211 07 CE Storage oF (oC) 22 to 140 (30 to +60) Operation oF (oC) 4 to 140 (20 to +60)
Approvals
23
Ambient air temperature around the device
Table 23.121: RE48 Panel Mount Timers (For required socket, refer to the catalog section)
Functions Single function: on delay, two relay outputs Repeat cycle: two relay outputs Multi-function: on delay, one shot, off delay, repeat cycle Multi-function: on delay and interval, two relay outputs, of which one selectable and instantaneous Conforming to standards Supply Voltages 24240 Vac/Vdc 24240 Vac/Vdc 24240 Vac/Vdc 24240 Vac/Vdc Rated Current 2x5A 2x5A 2x5A 2 x 5A Catalog Number RE48ATM12MW RE48ACV12MW RE48AML12MW RE48AMH13MW $ Price 87.00 104.00 102.00 102.00
IEC 61812-1, EN 50081-1/2, EM 50082-1/2, LV directives (73/23/EEC + 93/68/EEC (CE marking) + ENC directive (89/336/EEC + IEC 60669-2-3) cURus File: E173076 CNN: NRNT2 File: E173076 CNN: NRNT8 File: 217698 Class: 3211 07
Approvals
CSA CE, C-Tick, GL RoHS compliant as of date code 0625 Storage oF (oC) 40 to 158 (40 to +70) Operation oF (oC) 4 to 122 (20 to +50)
Table 23.122: REXL Miniature Plug-in Timers (For required socket, refer to the catalog section)
4 pole Rated Rated Current Catalog Number $ Price Current 12 Vdc 3A REXL4TMJD 66.00 5A 24 Vdc c 3A REXL4TMBD 66.00 5A Single function (On-Delay 24 Vac 50/60 Hz c 3A REXL4TMB7 66.00 5A 120 Vac 50/60 Hz 3A REXL4TMF7 66.00 5A 230 Vac 50/60 Hz 3A REXL4TMP7 66.00 5A Timing Ranges 0.11 s, 110 s, 0.11 min, 110 min, 0.11 hr, 110 hr, 10100 hr For 48 Vac supply, additional resistor 390 ohm 4 W / 24 V c For 48 Vac supply, additional resistor 560 ohm 2 W / 24 V Function Supply Voltages 2 pole Catalog Number REXL2TMJD REXL2TMBD REXL2TMB7 REXL2TMF7 REXL2TMP7 $ Price 63.00 63.00 63.00 63.00 63.00
Approvals:
File Class
217698 321107
IEC 61812-1
23-24
CP1
Discount Schedule
Timers
www.schneider-electric.us
RE7
Refer to Catalog 9050CT0001
RE7MY
2 C/O, DPDT Same as 6 Function Timer a plus Timer for star-delta starting with double On-Delay timing with changeover contact to star connection 24 Vdc or Vac 110240 Vac 2 C/O, DPDT 24240 Vdc or Vac a Except control of partial stop of time delay for RE7MY13BU. RE7MY13MW 342.00 RE7MY13BU 311.00
On-Delay Timer On-Delay Timer External control possible for: start of time delay partial stop of time delay adjustment of time delay b On-Delay Timer Remote control possible for: adjustment of time delay b
RE7TL11BU
171.00
2 C/Oc, DPDT
RE7T
RE7TP13BU
343.00
1 C/O, SPDT
RE7M
Asymmetrical Timers: On and Off delay times are adjusted separately. On-Delay and Off-Delay Timer 1 C/O, SPDT External control possible for: 24 Vdc or Vac partial stop of time delay 4248 Vdc or Vac RE7MV11BU 264.00 adjustment of time delay b 110240 Vac Start control via external contact only b By external potentiometer, to be ordered separately (see page 3 of Catalog 9050CT0001 for specifications). If external potentiometer is used, the internal potentiometer is automatically disconnected. c A switch on the front face of the timer allows the second contact to be used in instantaneous mode.
Product Approvals
IEC 61812-1
RE7, RE8, and RE9 Timers conform to European regulations relating to CE Marking -40oF to +185oF (-40oC to +85oC) -4oF to +140oF (-20oC to +60oC)
I11
Discount Schedule
23-25
23
RE7MA11BU
240.00
RE7
Refer to Catalog 9050CT0001
www.schneider-electric.us
Catalog Number
$ Price
RE7RB11MWa
233.00
RE7RB13MWa
264.00
RE7R
RE7RA11BU
203.00
SPDT On opening of Low Level External Control Contact, Adjustable from 0.05 s to 300 h, in 10 Ranges 1 C/O Off-Delay Timer 24 Vdc or Vac External control possible for: 4248 Vdc or Vac partial stop of time delay 110240 Vac adjustment of time delay b SPDT 2 C/Oc, DPDT 24 Vdc or Vac Off-Delay Timer 4248 Vdc or Vac 110240 Vac
RE7RM11BU
218.00
RE7RL13BU
233.00
a If the device has been stored de-energized for more than a month, it must be energized for about 15 seconds to activate it. Subsequently, a time of > 1 s is enough to activate the time delay. Note: If this time is not complied with, the relay will remain energized indefinitely.
RE7P
23
RELAYS AND TIMERS RE7C
Interval Timer
23-26
I11
Discount Schedule
Timers
www.schneider-electric.us
RE8/RE9
Refer to Catalog 9050CT0001
SPDT
110240 Vac
0.330 s RE8RB31BUTQ SPDT Also available in pack of one; delete TQ from the end of the catalog number. Example: RE8TA11BU.
0.110 s
RE8CL11BUTQ
10
125.00
110240 Vac
0.051 s
RE8PT01BUTQ
10
132.00
SPDT For easier adjustment, it is preferable to set the time delay between the maximum value in the range and one tenth of this value. Example: RE8TA11BUTQ timing range 0.110 s, recommended use 110 s. Orders must specify standard pack quantity or multiples of that quantity.
On-Delay
I11
Discount Schedule
23-27
23
Function
10 10 10 10 10 10
Type JCK
Class 9050 / Refer to Catalog 9050CT9601
www.schneider-electric.us
Up to 0.1% repeat accuracy Timing from 0.05 seconds to 999 hours Available in 5 timing modes DPDT contacts (2 N.O. and 2 N.C.) 10 A contact rating Transient protected Hold down spring available Variable or fixed time delay Horsepower rated
RoHS compliant
0.110 seconds JCK11f 78.00 JCK21f 98.00 JCK21PTf 0.330 seconds JCK12f 78.00 JCK22f 98.00 JCK22PTf 0.660 seconds JCK13f 78.00 JCK23f 98.00 JCK23PTf 1.2120 seconds JCK14f 78.00 JCK24f 98.00 JCK24PTf 1.8180 seconds JCK15f 78.00 JCK25f 98.00 JCK25PTf 0.110 minutes JCK16f 87.00 JCK26f 107.00 JCK26PTf 0.330 minutes JCK17f 87.00 JCK27f 107.00 JCK27PTf 0.660 minutes JCK18f 87.00 JCK28f 107.00 JCK28PTf 1.2120 minutes JCK19f 87.00 JCK29f 107.00 JCK29PTf a Two dials are provided for independently adjustable repeat cycle timing ranges. b Initiating contact can be up to 50 feet from the timer.
120 240
30 15
3 1.5
10 10
10 10
23
RELAYS AND TIMERS
JCK60f 152.00
Type JCK70
Two 5 position rotary switches are used to select the timing mode and timing range. The three pushbutton thumbwheels are used to select the time value. Table 23.142: Selection and Pricing
Timing Timing Type $ Price Modes Range On Delay Off Delay Same as Interval JCK70f 173.00 JCK60 One Shot Repeat Cycleg g The repeat cycle mode utilizes the same on-time and off-time.
23-28
CP2
Discount Schedule
Timers
www.schneider-electric.us
Types A and H
Class 9050 / Refer to Catalog 9050CT9901
Square D Pneumatic One minute timing 10% repeat accuracy SPDT or DPDT instantaneous contacts (Type A only) On and Off Delay, convertible SPDT or DPDT timed contacts Small size Low cost
Table 23.145: Selection and Pricing
Number of Contacts Mode of Operation Time Delay Instantaneous AC Operated DC Operated
Type AO10E
Type HO10E
Open Type $ Price Open Type $ Price N.O. N.C. 0 0 AO10Ea 504.00 HO10Ea 777.00 1 1 1 1 AO11Ea 629.00 2 2 AO12Ea 675.00 On Delay Convertible 0 0 AO20Ea 549.00 HO20Ea 569.00 2 2 1 1 AO21Ea 675.00 2 2 AO22Ea 720.00 0 0 AO10Da 504.00 HO10Da 518.00 1 1 1 1 AO11Da 629.00 2 2 AO12Da 675.00 Off Delay Convertible 0 0 AO20Da 549.00 HO20Da 569.00 2 2 1 1 AO21Da 675.00 2 2 AO22Da 720.00 On and Off Delay 1 per Head 1 per Head 0 0 AO110DEa 818.00 Double Headed 2 per Head 2 per Head 0 0 AO220DEa 909.00 a Voltage code must be specified to order this product. Refer to standard voltage codes listed below and insert as shown in How To Order. N.O. N.C.
Types A and H
File CCN E78403 NKCR File Class 060905 3211 03
14
228.00
24 Vac 2959S49W25A 2959S49W25B 110/115 Vac 2959S49W31B 2959S49W32A 120 Vac 2959S49W32A 2959S49W32B 208 Vac 2959S49W34A 2959S49W34B 220 Vac 2959S49W34B 2959S49W35A 74 68 240 Vac 2959S49W35A 2959S49W35B 277 Vac 2959S49W35B 440 Vac 2959S49W37B 2959S49W38A 480 Vac 2959S49W38A 2959S49W38B 550 Vac 2959S49W38B 2959S49W39A c 6 to 24 Vac coils have VA ratings 120% of the values shown
CP1
Discount Schedule
23-29
23
17
144.00
Timing Modes: On Delay or Off Delay, convertible. On Delay types can be wired for interval-maintained start or repeat cycle (sequencing using two devices). Timed and Instantaneous Output Contacts: SPDT or DPDT snap switch. Contacts of each pole must be used on same polarity. Repeat Accuracy: Under constant temperature (Per NEMA Standard ICS 5-1993). 10% to 1 minute max. Timing Range: Type A: 0.1 second to 1 minute. Type H: 0.15 second to 1 minute. Reset Time: Type A: On Delay 29 ms, Off Delay 27 ms average. Type H: On Delay 50 ms, Off Delay 70 ms average. Operating Temperature Range: 20oC to 40oC (68oF to 104oF) Operating Voltages/Voltage Range: Type A6 through 600 volts AC, +10%, -15% of nominal Type H6 through 250 volts DC, +10%, -20% of nominal
Monitors a.c. currents Designed to monitor overcurrent Equipped with an integrated current transfmormer
Output 5Amps 1 C/O
Selection between overcurrent or undercurrent Automatic d.c. or a.c. recognition Selectable memory function
Table 23.151:
RM17JC00MW
Supply Voltage Measurement Range Rangea 220 A 220 mA 10100 mA 50500 mA 0.151.5 A 0.55 A 1.515 A Terminals N/A E1-M E2-M E3-M E1-M E2-M E3-M Width Inches 0.69 mm 17.50 Catalog Number RM17JC00MW RM35JA31MW 2 C/O 1.38 35.00 RM35JA32MW 210.00 $ Price 155.00 176.00
24240 Vac/dc
Above 15A, a current transformer can be connected (for RM35JA3MW). See page 57 of the catalog for suggested wiring.
RM35JA31MW
Approvals:
File CNN E173076 NRNT File Class 217698 3211 07 CE: 73/23/EEC and EMC 89/336/EEC GL, C-Tick, GOST, RoHS
90/3.54
1 C/O = 2 C/O =
76/2.99 72.5/2.85 2.8 0.11
12 11 14 22 21 24
101/3.98 97.5/3.84
2.8 0.11
Dual Dimensions:
INCHES Millimeters
23-30
CP1
Discount Schedule
90/3.54
23
RM35JA32MW RELAYS AND TIMERS
Approximate Dimensions
RM35JA3MW
72/2.83 35/1.38
A1 A2 E3 E2 E1 M
RM17JC00MW
97/3.82 17.5 0.69
10/0.39
RM17T00
Refer to Catalog 8430CT0601
New!
RM17TG0
208480 Vac
1 C/O
0.69
17.50
Table 23.155: RM17TT, RM17TA, RM17TU, and RM17TE multifunction control relays monitor the following on 3-phase supplies:
Function Sequence of phases L1, L2 and L3 Phase failure with regeneration (0.7 x selected voltage range) Asymmetry (phase imbalance) Undervoltage Overvoltage and undervoltage RM17TT Yes Yes No No No RM17TA Yes Yes Yes No No RM17TU Yes Yes No Yes No RM17TE Yes Yes Yes No Yes
RM17TA00
Table 23.157: RM35TM control relays monitor the following on 3-phase supplies:
RM17TE00
Function Sequence of phases L1, L2 and L3 Phase failure Motor temperature via PTC probe Selection (with or without memory) Test-reset button RM35TM50MW Yes Yes Yes No No RM35TM250MW Yes Yes Yes Yes Yes
RM35TF30 measurement and control relay is for monitoring of phase sequence, phase failure, asymmetry, undervoltage and overvoltage in window mode. Table 23.158: Multifunction 3-phase supply control relays
Supply Voltage 24240 Vac/Vdc Measurement Range 194528 Vac Output 5 Amps 2 C/O Width inch 1.38 mm 35.00 Catalog Number RM35TF30 $ Price 324.00
Approvals:
RM35TMMW
File CNN E173076 NRNT File Class 217698 3211 07 CE: 73/23/EEC and EMC 89/336/EEC GL, C-Tick, GOST, RoHS
RM35
RM17
72/2.83
35/1.38
72/2.83
17.5 0.69
90/3.54
2 C/O = 2 N/O =
2.8 0.11
76/2.99 72.5/2.85
76/2.99 72.5/2.85
Dual Dimensions: INCHES Millimeters
2.8 0.11
1 C/O =
CP1
Discount Schedule
23-31
90/3.54
RM35TF30
23
Approximate Dimensions
1 C/O
0.69
17.50
Provides overvoltage or undervoltage protection. Provides overvoltage and undervoltage protection in window mode.
Multifunction voltage control relays RM35UA1MW monitor both a.c. and d.c. voltages.
RM35UB3
186.00
24240 Vac/Vdc
2 C/O
1.38
35.00
RM35UA12MW
186.00
RM35UA13MW
186.00
Failure of one or more phases Voltage between phases Absence of neutral Voltage between phases and neutral Overvoltage and undervoltage
90/3.54
2.8 0.11
76/2.99 72.5/2.85
76/2.99 72.5/2.85
Dual Dimensions: INCHES Millimeters
23-32
2.8 0.11
CP1
Discount Schedule
90/3.54
23
RELAYS AND TIMERS RM35UA1MW 1 C/O = 2 C/O =
Provides overvoltage and undervoltage protection between phases. Provides overvoltage and undervoltage protection between phases and neutral and absence of neutral.
Approvals:
File CNN E173076 NRNT File Class 217698 3211 07 CE: 73/23/EEC and EMC 89/336/EEC GL, C-Tick, GOST, RoHS
Approximate Dimensions
RM35 RM17
72/2.83
35/1.38
72/2.83
17.5 0.69
RM35LMW, RM35BA10
Refer to Catalog 8430CT0601
New!
Liquids in the food-processing industry: milk, beer, coffee, etc. Chemically pure water Fuels, liquid gasses (inflammable) Oil, concentrated alcohol (>40%) Ethylene, glycol, paraffin, varnish and paints
RM35LM33MW
Detecting pump seal failures Spring, town, industrial and sea water Metallic salt, acid or base solutions Liquid fertilizers Non-concentrated alcohol (<40%)
RM35LM33MW RM35LV14MW
137.00 174.00
RM35LV14MW
Recommended for drink vending machines and where 3 176 80 installation space is limited (stainless steel)a Suitable for boilers, pressure vessels, and under high 1 392 25 temperature conditions (1) (304 stainless steel)a a 3/8 BSP mounting thread with hexagonal head. Use a 24mm spanner for tightening.
RM79696043
Pump control relay RM35BA10 can operate on a single-phase or 3-phase supply. It incorporates three functions in a signal unit:
It has two operating modes which are designed to control a pump via two external signal inputs (Y1 Y2). These two signals are controlled by volt-free contacts. Control inputs Y1 and Y2 can be connected to:
Level sensor
Level relay
Pressure sensor
Push button
Approvals:
File CNN E173076 NRNT File Class 217698 3211 07 CE: 73/23/EEC and EMC 89/336/EEC GL, C-Tick, GOST, RoHS
RM79696006
Approximate Dimensions
RM35LM33MW, RM35LV14MW
72/2.83 35/1.38 72/2.83
E1
RM35BA10
35/1.38
L1 L2 L3
90/3.54
>I <I
Def. Un R
1 C/O =
76/2.99
2.8 0.11
2.8 0.11
RM35BA10
Y1 Y2
12 11 14
76/2.99 72.5/2.85
90/3.54
2 C/O =
72.5/2.85
Dual Dimensions:
INCHES Millimeters
CP1
Discount Schedule
23-33
23
Zelio Speed Control Relays, Zelio Frequency Control Relays, and Zelio Temperature Control Relays
Zelio speed control relay RM35SOMW monitors underspeed and overspeed, with or without memory, with inhibition by an external contact. It operates with either N.O. or N.C. sensors. Adjustable time between impulses is 0.05s to 10m. Power-on inhibition time is adjustable from 0.6 to 60s. Inhibition is controlled by an external contact. Settings are protected by a sealable cover, control status is indicated by an LED, and it is DIN rail mountable. Table 23.167: Speed Control Relay
Function Time Delay 0.05s10min Measurement Input 3-wire PNP or NPN proximity sensor Namur proximity sensor 030 V voltage Volt-free contact Supply 24240 Vac/Vdc Output 1 C/O 5A Catalog Number RM35S0MW $ Price 258.00 Underspeed Overspeed
RM35S0MW
Zelio frequency control relay RM35HZ monitors its own supply voltage. Settings are protected by a sealable cover, control status is indicated by an LED, and it is DIN rail mountable. Table 23.168: Frequency Control Relay
Function Over frequency and under frequency (50 or 60 Hz) Controlled 4060 Hz (50 Hz) / 5070 Hz (60 Hz) Supply Voltage 120277 Vac Output 1 C/O + 1 C/O 5A Catalog Number RM35HZ21FM $ Price 264.00
RM35HZ21FM
Zelio temperature control relays are designed for monitoring the temperature in elevator (lift) pully rooms, in compliance with directive EN81. For use with PT100 input (customer supplied). Features adjustable control, control status is indicated by an LED, and it is DIN rail mountable. Table 23.169: Temperature Control Relays
Function Over temperature 93 to 114F (34 to 46C) Under temperature 30 to 51F (-1 to 11C) Over temperature 93 to 114 F (34 to 46C) Under temperature 30 to 51F (-1 to 11C) Phase sequence Phase failure Supply Voltage Vac 24240 Vac/Vdc 208480 Vac 2 N.O. 5A RM35ATW5MW 282.00 Output 1 C/O 5A 2 N.O. 5A Catalog Number RM35ATL0MW RM35ATR5MW $ Price 167.00 179.00
Approvals:
RM35AT0MW
File CNN E173076 NRNT File Class 217698 3211 07 CE: 73/23/EEC and EMC 89/336/EEC GL, C-Tick, GOST, RoHS
90/3.54
2.8 0.11
2.8 0.11
12 11 14 22 21 24
76/2.99 72.5/2.85
76/2.99 72.5/2.85
RM35ATMW
72/2.83 35/1.38
76/2.99 72.5/2.85
2.8 0.11
90/3.54
Dual Dimensions:
INCHES Millimeters
23-34
CP1
Discount Schedule
90/3.54
23
Approximate Dimensions
1 C/O = RELAYS AND TIMERS 2 N/O =
72/2.83
RM35S0MW
35/1.38
72/2.83
RM35HZ21FM
35/1.38
A1 A2
Type MP
Class 8430 / Refer to Catalog 8430CT9701
Yes
Yes
Yes
Yes
Phase Failure and Undervoltage Relay The Type MPS is a socket mounted, voltage sensing phase failure relay. The undervoltage setting is adjustable from 75% to 100% of normal voltage. The relay is UL Listed with the appropriate socket (see socket selection on page 23-13). The 240 V rated, SPDT output contacts change state upon phase failure, undervoltage, phase reversal or phase unbalance of 10% or greater. Response time delay is 3 seconds.
8430 MPS 12060 Phase Failure and Undervoltage Relay The Type MPD offers the same protection as the Type MPS plus the following features: DPDT 600 V rated output contacts, locking potentiometer undervoltage adjustment and an LED indicating relay energized. Can be mounted directly to a panel or to 8501 XM track (see page 23-23). 24060 DPDT 48060 60060 Note: For 8430 MPS Sockets, see page 23-13. MPDV29 MPDV32 MPDV20 MPDV24 732.00
Yes
Yes
Yes
Yes
8430 MPD
MPS:
File E78403 CCN NLDX provided the proper socket is used. 8430MPSV24 - 8501 NR51 or NR52 socket (see page 23-13). 8430MPSV29 - 8501 NR82 socket (see page 23-13).
MPD:
MPS MPD
SPDT DPDT
For Mounting Track for the 8430 MPS relays . . . . . . . . . . . . . . . . .page 23-23
3.39 86 3.98 101 1.73 44
2.20 56 1.10 28
2.36 60
2.36 60
3.50 89
3.11 79
3.35 85
2.75 70
4.09 104
3.50 89
Prov. for (2) #8 Mtg. Screws
Type MPD
23-35
23
RC87610
Refer to Catalog 9051CT0501
www.schneider-electric.us
This type of counter is typically used on simple machines to keep a running total of the number of cycles the machine has performed or the total amount of time that a machine has been running. This information can be very useful in a preventative maintenance program.
Totalizing Counters
RC87610050
A totalizing counter is used to count electrical pulses or contact closings. The display will show the value and update this value after each pulse. They count up only and can be reset on the front of the device or remotely. Table 23.174: Totalizing Counters
Description 8 Digit LCD, 40 Hz input 8 Digit LCD, 14 or 100 Hz input 8 Digit LCD, 14 Hz input 8 Digit LCD, 40 Hz or 7 kHz input Catalog Number RC87610050 RC87610240 RC87610250 RC87610340 $ Price 116.00 140.00 140.00 42.30
24 x 48 mm Totalizing Counter
Hour Counters
An hour counter is used to count the elapsed time and display the value. They count up only and can be reset on the front of the device or remotely.
RC87610340
Accessories
These adaptors are used to mount above counters in holes other than 24x48 mm. Table 23.176: Mounting Adapters
RC87610050
Description Adapters for panel cut-out in. 0.98x1.96 1.77x1.77 1.96 diameter Dimensions mm 25x50 45x45 50 diameter Catalog Number RC26546829 RC26546830 RC26546831 $ Price 5.00 5.00 9.90
File Class
217698 3211 07
IEC 61010
Approximate Dimensions
Table 23.178:
RC87610050
1.7 (44. 6 6)
0.94 (24)
210
0.86 (21.8)
0.94 (24)
1.8 (48)9
1.89 (48)
2 2.5 ) (64
0.1 (3)
RC87610150
RC87610340 / RC87610440
1.76 (44.6 )
0.94 (24)
210
0.86 (21.8)
0.94 (24)
1.8 (48)9
1.89 (48)
2 2.5 ) (64
0.1 (3)
Table 23.179:
RC26546830
Panel cut-out
+ 0,5 -0
23-36
0.79 (20)
0.89 - 0 (22)
1.77 (44.8)
1.18 (30)
+ 0,3
CP1
Discount Schedule
0.86 (21.8)
1.76 (44.6)
0.86 (21.8)
23
RELAYS AND TIMERS
RC87610240 / RC87610250
1.76 44.6
Other Products
www.schneider-electric.us
New!
Voltage holding during power outages Voltage holding during power supply equipment failure
Table 23.180: Modular, Single Phase Meets all the needs of simple automation systems with power ratings from 7 to 60 W and an output voltage of 5 Vdc, 12 Vdc, or 24 Vdc.
Input Voltage (Vac) Output Voltage (Vdc) 5 12 24 Nominal Current (I) 4 2 0.3 0.6 1.2 2.5 Protection Reset Catalog Number ABL8MEM05040 ABL8MEM12020 ABL8MEM24003 ABL8MEM24006 ABL8MEM24012 ABL7RM24025 $ Price 128. 132. 71. 105. 141. 180.
ABL8MEM12020
100240
Auto
Table 23.181: Optimum, Single Phase The low-cost solution for applications supplied at 12 Vdc, 24 Vdc, or 48 Vdc and requiring currents between 3 and 5 A.
Input Voltage (Vac) 100240 Output Voltage (Vdc) 12 24 48 Nominal Current (I) 5 3 5 3 Protection Reset Auto Catalog Number ABL7RP1205 ABL8REM24030 ABL8REM24050 ABL7RP4803 $ Price 360. 195. 300. 225.
ABL8REM24030
Table 23.182: Universal, Single Phase Adapts to the majority of power distribution systems with power ratings from 72 to 480 W at 24 Vdc. The same power supply can be connected phase-to-neutral (N-L1) or phase-to-phase (L1-L2) for line supplies ranging from 100 to 500 Vac nominal. Energy reserve, diagnostics, and choice of manual or auto reset are integrated into these units.
Input Voltage (Vac) 100120 / 200500 100120 / 200240 Output Voltage (Vdc) Nominal Current (I) 3 5 10 20 Auto-Protection Reset Catalog Number ABL8RPS24030 ABL8RPS24050 ABL8RPS24100 ABL8RPM24200 $ Price 270. 360. 525. 716.
24
Auto/Manual
ABL8RPS24100
Table 23.184: Dedicated, Single Phase Designed for integration into repetitive equipment with power ratings from 60 to 240 W and an output voltage of 12 Vdc or 24 Vdc.
.
ABL8WPS24200
Protection Reset
Catalog Number ABL1REM12050 ABL1REM24025 ABL1REM24042 ABL1REM24062 ABL1REM24100 ABL1RPM12083 ABL1RPM24042 ABL1RPM24062 ABL1RPM24100
$ Price 113. 93. 132. 143. 206. 150. 158. 173. 270.
100240a
24 24 12 24 24
Auto
Auto
ABL1RPM24042
a b
100120 / 200240b
Compatible input voltage 120-370 Vdc not indicated on the product. Compatible input voltage 180-370 Vdc not indicated on the product.
Approvals:
ABL1RPM24100
File CCN E164867, NMTR, NMTR7 File E164867, CCN NMTR2, NMTR8 File Class Class 238438 5311-87 5311-07 RoHS Compliant
See www.Schneider-Electric.com for UL and CSA compliances. For additional information, refer to Catalog #8440CT0601.
CP12
Discount Schedule
23-37
23
Table 23.183: Universal, Three Phase This three-phase, 480 to 960 W, 24 Vdc output offering is particularly suited for complex machines and processes. Energy reserve, diagnostics and choice of manual or auto reset are integrated into these units.
Interface Modules
Zelio Analog Interface Modules
RM
Refer to Catalog 8501CT0502
www.schneider-electric.us
The Zelio Analog range of converters is designed to convert signals emitted by sensors or electrical measurement devices, into standard electrical signals that are compatible with automation platforms and controllers. They also allow the connection distance between a sensor and a measurement device to be increased, for example, between a thermocouple and a programmable controller Table 23.185: Converters for Type J and K type thermocouplessupply voltage 24 Vdc 20%, non-isolated
Type Temperature Range F 32302 32572 321112 321112 322192 C 0150 0300 0600 0600 01200 Switchable Output Signals 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA Catalog Number RMTJ40BD RMTJ60BD RMTJ80BD RMTK80BD RMTK90BD $ Price 168.00 168.00 168.00 168.00 168.00
RMTJ40BD
Type J Type K
Table 23.186: Converters for Universal Pt100 probessupply voltage 24 Vdc 20%, non-isolated
Type Temperature Range F - 40104 - 148212 32212 32482 32932 C - 4040 - 100100 0100 0250 0500 Switchable Output Signals 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA 010 V, 020 mA, 420 mA Catalog Number RMPT10BD RMPT20BD RMPT30BD RMPT50BD RMPT70BD $ Price 168.00 168.00 168.00 168.00 168.00
RMTK90BD
Table 23.187: Converters for Optimum Pt100 probesasupply voltage 24 Vdc 20%, non-isolated
F C - 40104 - 4040 - 148212 - 100100 Pt100 2-wire, 3-wire, and 32212 0100 4-wire 32482 0250 32932 0500 a Converters dedicated to Zelio Logic smart relays. Type Temperature Range Switchable Output Signals 010 V or 420 mA 010 V or 420 mA 010 V or 420 mA 010 V or 420 mA 010 V or 420 mA Catalog Number RMPT13BD RMPT23BD RMPT33BD RMPT53BD RMPT73BD $ Price 134.00 134.00 134.00 134.00 134.00
RMPT70BD
23
RELAYS AND TIMERS RMPT13BD RMCN22BD
Approvals:
File CCN
E164353 NKCR
File Class
089150_S_000 3211 07
IEC 60947-1
RoHS Compliant
23-38
CP1
Discount Schedule
Other Products
www.schneider-electric.us
Zelio Logic 2 smart relays meet the demands of applications that require more flexibility than a simple relay, timer, or counter, but are too small or simple for the smallest Nano PLC. The Zelio Logic SR2 range is an exact replacement for the obsolete SR1 range, but with an expanded feature set. Designed to accept control outputs just like a relay, Zelio Logic 2 features dual language capability, using either Function Block Diagramming (FBD) or Ladder Logic Programming (LL), and can be programmed easily by using either the front panel or by using ZelioSoft software. Table 23.190: Compact Smart Relays with Display, DC Power Supply
Supply voltage Number of inputs/outputs Discrete inputs Number of inputs Including 0-10 V analog inputs Number of outputs Dimensions, W x D x H (mm) Clock Catalog Number 12 8 4 4 relay
12 Vdc 20 12 6 8 relay 124.6x59.5x107.6 yes SR2B201JD 398.00 no SR2A101BD c 232.00 10 6 4 relay 12 8 4 4 relay 71.2x59.5x107.6 yes SR2B121BD 282.00 yes SR2B122BD 276.00 12 8 4 4 transistor
24 Vdc 20 12 2 8 relay no SR2A201BD c 358.00 20 12 6 8 relay 124.6x59.5x107.6 yes SR2B201BD 398.00 yes SR2B202BD 392.00 20 12 6 8 transistor
$ Price 282.00 a Programming of smart relay in LADDER language only. b Please consult Schneider Electric representative for list prices.
Supply voltage Number of inputs/outputs Number of inputs Number of outputs Dimensions, W x D x H (mm) Clock Catalog Number $ Price c Programming of smart relay in LADDER language only. Discrete inputs 12 8 4 relay
24 Vac 20 12 8 relay 124.6x59.5x107.6 yes SR2B201B 398.00 no SR2A101FU a 258.00 10 6 4 relay 71.2 x 59.5 x 107.6 yes 12 8 4 relay
SR2B121FU 288.00
Table 23.192: Compact Smart Relays without Display and without Buttons, DC and AC Power Supply
Supply voltage Number of inputs/outputs Number of inputs Number of outputs Dimensions, W x D x H (mm) Clock Catalog Number no SR2D101BD d Discrete inputs Including 0-10 V analog inputs 12 6 4 relay
24 Vdc 20 8 4 4 relay yes SR2E121BD b 20 12 6 8 relay 124.6x59.5x107.6 yes SR2E201BD bc 10 6 4 relay no SR2D101FU d
$ Price 214.00 222.00 338.00 218.00 226.00 344.00 d Programming of smart relay in LADDER language only. e To order a smart relay for a 24 Vac supply (no analog inputs), delete the letter D from the end of the catalog number (SR2E121B and SR2E201B). f To order a smart relay without a clock, replace the letter E with the letter D (Example: SR2D201BD and SR2D201FU (these units can only be programmed in LADDER language.
Discount Schedule
23-39
23
20
20
Other Products
Table 23.193: Modular Smart Relays a with Display, DC and AC Power Supply
Supply voltage Number of inputs/outputs Number of inputs Number of outputs Dimensions, W x D x H (mm) Clock Catalog Number $ Price a b c Discrete inputs Including 0-10 V analog inputs
124.6x59.5x107.6 71.2x59.5x107.6
SR3B10pBD bc SR3B26pBD bc
380.00 282.00 476.00 292.00 486.00 The modular base can be fitted with one I/O extension module. The 24 Vdc modular base can be fitted with one communication module and/or one I/O extension module. Replace the p by the number 1 to order a smart relay with relay output or by 2 for a smart relay with transistor output (Example: SR3B101BD). Please consult local Schneider Electric representative for list prices.
23
Application Number of inputs/outputs Number of inputs Number of outputs Discrete inputs Analog (010 V, 020 mA, PT100) Relay Analog (0-10 V)
Discrete Inputs/Outputs 10 6 4 relay 72x59.5x107.6 14 8 6 relay 72x59.5x107.6 Cat. No. SR3XT141JD SR3XT141BD SR3XT141B SR3XT141FU $ Price 140.00 164.00 164.00 164.00
Dimensions, W x D x H (mm)
Voltage
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 12 Vdc SR3XT61JD 80.00 SR3XT101JD 100.00 24 Vdc SR3MBU01BD 200.00 SR3XT61BD 106.00 SR3XT101BD 126.00 24 Vac SR3XT61B 106.00 SR3XT101B 126.00 100-240 Vac SR3XT61FU 106.00 SR3XT101FU 126.00 a The power supply of the extension modules is provided via the Zelio Logic 2 modular relays. b max. 1 PT 100 input
Approvals:
File CCN E164866 NRAQ File Class LR217698 2252 01
23-40
Discount Schedule
Other Products
www.schneider-electric.us
ABS
Refer to Catalog 8501CT9401
ABS2EA01EM
5 to 48 Vdc 5 to 48 Vdc 5 to 48 Vdc 2/60 Vdc 2/60 Vdc 2/60 Vdc 1/50 mA 1/50 mA 1/50 mA Conforming to IEC 60947-1: 300 V Conforming to IEC 0110: 250 V group C UL E164353, CSA 081630, IEC 60947-1
Dimensions (W x D x H)a Control Circuit Characteristics Rated Voltage Us Maximum Voltage Maximum Current at Us Internal Protection against reverse polarity Output Circuit Characteristics Rated Operational Voltage Ve Maximum Voltage Internal Protection against reverse polarity
ABS2SA01MB
External Protection Rated insulation voltage Approvals a Dimensions mounted on DIN 3 (7.5 mm high) track. For Mounting Track, see page 24-16.
CP1
Discount Schedule
23-41
23
5 to 48 Vdc 24 to 240 Vac 24 to 240 Vac 57.6 Vdc 264 Vac 264 Vac Yes Yes Yes Against short-circuits for 1k, 1k (Ac) and <100 A (DC) Quick-blow fuse with very high breaking capacity: 3.15 A Conforming to IEC 60947-1: 300 V Conforming to VDE 0110: 250 V group C UL E164353, CSA 081630, IEC 60947-1
Other Products
ABR
Refer to Catalog 8501CT9401
www.schneider-electric.us
81.00
Manual Operator
LED Indication
23
ABR1S111F RELAYS AND TIMERS ABR2S102B
Maximum Voltage Pick-up Voltage Minimum Sealed Current Maximum Sealed Current
23-42
CP1
Discount Schedule
Type SSR
Refer to Catalog 8501CT0601
New!
Solid state relays do not have any moving parts to wear out. Combined with vibration resistance, arc-less switching and the lack of acoustical noise, you have the ideal product for switching applications that demand reliable execution. For added reliability the Zelio SSRP and SSRD solid state relays utilize Direct Copper Bonding (DCB) technology to decrease internal temperatures and improve the overall quality of the product. Key features include:
SSRPCDS25A1
Input voltage range 3 to 32 Vdc, 90 to 280 Vac Breaking capacities up to 125 A Zero voltage turn on, low EMI / RFI No moving parts Shock and Vibration resistant No acoustical noise Fast response Arc-less switching Long life (>109 operations)
SSRDCDS10A1
SSRDCDS45A1
90140 AC
SSRAH1
SSRAT1
CP1
Discount Schedule
23-43
23
Type REG
Refer to Catalog 8430CT0601
www.schneider-electric.us
The new Zelio REG temperature controllers offer seamless interfacing with solid state relays, electromechanical relays, PLCs, variable speed drives and HMI displays make them a key component to controlling the temperature in your process. Offer includes 3 versions:
REG24PTP1RHU
A 24x48 (1/32 DIN) cost effective solution for basic temperature control needs. A 48x48 mm (1/16 DIN) balanced version for optimal price and functionality. A 96x48 mm (1/8 DIN) full-featured version for complete performance and function. Modbus communication for easy data exchange with other automation products Simple parameter settings IP66 certification enables dust resistance Flash memory (saves configurations) Compatible with a wide range of sensors Advanced Functions (standard): PID, fuzzy logic, auto-tuning, soft start Optimized programming
Common software for all products in the temperature relay range (freely downloadable from schneider-electric.com). A single cable enables connection to both a computer and PLCs. Simple adjustment of parameters. Saving of configurations.
100/240 Vac Thermocouple PT100 Probe 24 Vac/Vdc 100/240 Vac Voltage/current 24 Vac/Vdc 48 x 48 Size 1/16 DIN Standard
23
Universal
100/240 Vac
1 solid state relay 1 solid state relay + 1 electromechanical relay 1 analog interface (420 mA) 1 solid state relay + 1 analog interface (420 mA) 1 electromechanical relay 2 electromechanical relays 1 solid state relay 1 solid state relay + 1 electromechanical relay 1 analog interface (420 mA) 1 solid state relay + 1 analog interface (420 mA) 1 electromechanical relay 2 electromechanical relays
REG96PUN1RHU
24 Vac/Vdc
100/240 Vac
1 solid state relay 1 solid state relay + 1 electromechanical relay 1 analog interface (420 mA) 1 solid state relay + 1 analog interface (420 mA) 1 electromechanical relay 2 electromechanical relays 1 solid state relay 1 solid state relay + 1 electromechanical relay 1 analog interface (420 mA) 1 solid state relay + 1 analog interface (420 mA)
Universal
24 Vac/Vdc
23-44
CP1
Discount Schedule
RSL
RSL 1PV
RSL 1PR
Catalog Numbera 12 12 RSL1PVJU 24 24 RSL1PVBU 48 48 RSL1PVEU 110 60 RSL1PVFU 230 60 RSL1PVPU Relays are mounted on sockets equipped with LED and protection circuit.
Table 23.211: Zelio RSL Slim Interface: Relay Only (sold in lots of 10)
Relay Coil Voltage (Vdc) 12 24 48 60 Catalog Number RSL1AB4JD RSL1AB4BD RSL1AB4ED RSL1AB4ND $ Price ea. 7.40 9.10 9.40 9.40
RSL 1AB
Table 23.212: Zelio RSL Slim Interface: Socket Only (sold in lots of 10)
Socket Supply Voltage (Vac/Vdc) 12 24 48 60 110 230 Socket Type For use with relays: RSL1AB4JD RSL1AB4BD RSL1AB4ED RSL1AB4ND RSL1AB4ND RSL1AB4ND Screw Connector Catalog Number RSLZVA1 RSLZVA2 RSLZVA3 RSLZVA4 $ Price ea. 8.50 8.50 8.80 8.80 Spring Terminal Catalog Number RSLZRA1 RSLZRA2 RSLZRA3 RSLZRA4 $ Price ea. 9.90 9.90 10.20 10.20
RSL ZVA
RSL ZRA
RSL Z2
CP1
Discount Schedule
23-45
23
www.schneider-electric.us
23
RELAYS AND TIMERS
23-46
Table of Contents
Section 24
Terminal Blocks
Track-Mounting Terminal Blocks & Prewired Connectors
Advantys TELEFAST 2 NEMA Style IEC Style
AB1RRN, p. 24-3 AB1AA, p. 24-10
Circuit Protectors
Class 9080 Type GCB GB2
AB1VV, p. 24-5 9080GR6, p. 24-13
24-17 24-17
Fuseholders
Panel Mounting NEMA Style IEC Style
GB2, p. 24-17 9080GCB, p. 24-17
Class 9080 Type FB Class 9080 Type GF6 AB1FU, AB1SF AB1AASF AB1RRNSF DF
AT1
Mounting Track
9080GH (Square D) 9080MH (DIN) 24-16 24-12
9080FB, p. 24-19
9080GF6, p. 24-14
DZ5, p. 24-20
24-1
24
TERMINAL BLOCKS
Selection Guide
Terminal Blocks
Refer to Catalog 9080CT9901R7/07 and 9080CT9601
www.schneider-electric.us
Table 24.1:
Mounting
DIN 3
DIN 3
600
600
600
600 b
115
375
22
255
UL File 164359 CCN XCFR2 Approvals c CSA File 702070 Class 6228 01 Gray Blue Green/Yellow Black
CSA File 702070 Class 6228 01 Gray Blue Green/Yellow Orange Red Green White Black
CSA File 702070 Class 6228 01 Gray Blue Green/Yellow Orange Red
CSA File 025490 Class 3211 07 Natural (White) Black Blue Green Gray Orange Red Yellow Brown
Color
a b c
9080GK6 can be mounted directly to a panel or on Square D track. 9080GT6 is 120 V. Refer to catalogs 9080CT9901 and 9080CT9601 for a complete list of certifications.
24
TERMINAL BLOCKS
24-2
CP5
Discount Schedule
Table 24.2:
Spring-Clip, AB1RRN
Description Maximum Maximum Current Voltage b Block Color Catalog Number $ Price Std. ea. Packa 1.40 100 Color End Barrierc Catalog Number $ Price Std. ea. Packa 0.60 10
Spring-Clip Style Block Two Terminals 600 V Solid or Stranded Copper Wire 2212 AWG 20 A
Gray
AB1RRN235U2GR
Gray
AB1RRNAC242GR
Blue
AB1RRN235U2BL
1.40
100
Blue
AB1RRNAC242BL
0.60
10
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
CP5
Discount Schedule
24-3
24
TERMINAL BLOCKS
Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 2212 AWG 5 mm (0.20 in.) wide Spring-Clip Style Grounding Block Four Terminals Solid or Stranded Copper Wire 2212 AWG
600 V
20 A
Green / Yellow
AB1RRNTP235U2
5.10
100
Green
AB1RRNTPAC242
0.60
10
600 V
20 A
Green / Yellow
AB1RRNTP235U4
7.50
100
Green
AB1RRNTPAC244
0.75
10
Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 2210 AWG 6 mm (0.24 in.) wide Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 248 AWG 8mm (0.31 in.) wide Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 166 AWG 10 mm (0.39 in.) wide Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 2210 AWG 12 mm (0.47 in.) wide Spring-Clip Style Diode/Fuseholder Block
600 V
30 A
Green / Yellow
AB1RRNTP435U2
6.20
100
Green
AB1RRNTPAC242
0.60
10
600 V
50 A
Green / Yellow
AB1RRNTP635U2
6.90
50
Green
AB1RRNTPAC642
0.83
10
600 V
60 A
Green / Yellow
AB1RRNTP1035U2
7.80
50
Green AB1RRNTPAC1042
0.90
10
600 V
85 A
Green / Yellow
AB1RRNTP1635U2
9.30
50
Green AB1RRNTPAC1642
1.20
10
300 V Solid or Stranded Copper Wire 2210 AWG Fuseholder 5x20 (Fuse not included) Fuseholder 5x20 + 24 V LED Fuseholder 5x20 + 220 V LED Holder for Diode (Diode not included) Holder with1N4007-1 Diode
10 A
Gray
Gray
AB1RRNAC442GR
0.60
10
Gray
Not applicable
Table 24.4:
Mounts on 15 mm DIN 2 track Miniature Block with Box Lug Solid or Stranded Copper Wire 2210 AWG Mounts on 15 mm DIN 2 track 150 V 10 A
24
5 mm (0.20 in.) wide
Gray
AB1VV415
1.70
100
Gray
AB1AC2
0.62
10
TERMINAL BLOCKS
Miniature Grounding Block with Box Lug Solid or Stranded Copper Wire 2214 AWG 150 V 10 A Green / Yellow AB1TP215 4.40 100 Gray AB1CT215 0.62 50
Mounts on 15 mm DIN 2 track 6 mm (0.24 in.) wide a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation, class and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. c One end-barrier is required for each assembly of like blocks. For track and accessories, see pages 24-11 and 24-12.
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
24-4
CP5
Discount Schedule
Table 24.5:
5 mm (0.20 in.) wide Gray Blue Orange Box-Lug Style Block Solid or Stranded Copper Wire 2210 AWG 6 mm (0.24 in.) wide Green White Gray Box-Lug Style Block Solid or Stranded Copper Wire 228 AWG 8 mm (0.31 in.) wide 600 V 50 A Blue Orange 600 V 30 A Black Red
Gray Box-Lug Style Block Solid or Stranded Copper Wire 166 AWG 10 mm (0.39 in.) wide Gray Box-Lug Style Block Solid or Stranded Copper Wire 124 AWG 12 mm (0.47 in.) wide Gray Box-Lug Style Block Solid or Stranded Copper Wire 102 AWG 16 mm (0.63 in.) wide Gray Box-Lug Style Block Solid or Stranded Copper Wire 62/0 AWG 24 mm (0.94 in.) wide Gray Box-Lug Style Block Solid or Stranded Copper Wire 2/0350 kcmil 28 mm (1.10 in.) wide a b c 600 V 335 A Blue 600 V 175 A Blue 600 V 95 A Blue 600 V 85 A Blue 600 V 65 A Blue
AB1VVN1035U
2.70
50
Gray
AB1ACN10
0.78
10
AB1VVN1035UBL
2.70
50
Blue
AB1ACN10BL
0.78
10
AB1VVN1635U
5.40
50
Gray
AB1ACN16
0.93
10
AB1VVN1635UBL
5.40
50
Blue
AB1ACN16BL
0.93
10
AB1VVN3535U
7.70
AB1VVN3535UBL
7.70
20
AB1VVN7035U
27.90
AB1VVN7035UBL
27.90
20
AB1VVN15035U
65.00
AB1VVN15035UBL
65.00
10
Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks.
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
CP5
Discount Schedule
24-5
24
TERMINAL BLOCKS
Grounding Block Solid or Stranded Copper Wire 2210 AWG 5.1 mm (0.20 in.) wide Grounding Block Solid or Stranded Copper Wire 2210 AWG 6 mm (0.24 in.) wide Grounding Block Solid or Stranded Copper Wire 228 AWG 8 mm (0.31 in.) wide Grounding Block Solid or Stranded Copper Wire 166 AWG 10 mm (0.39 in.) wide 600 V Green/Yellow AB1TP1035U 7.80 50 Not required for this block. 600 V Green/Yellow AB1TP635U 6.90 100 Not required for this block. 600 V Green/Yellow AB1TP435U 6.20 100 Not required for this block. 600 V Green/Yellow AB1TP235U 5.30 100 Green AB1AC25 0.83 10
Grounding Block Solid or Stranded Copper Wire 124 AWG 12 mm (0.47 in.) wide 600 V Green/Yellow AB1TP1635U 9.30 50 Not required for this block.
Grounding Block Solid or Stranded Copper Wire 102 AWG 16 mm (0.63 in.) wide 600 V Green/Yellow AB1TP3535U 13.20 20 Not required for this block.
Table 24.7:
a b
Standard two tier block Gray AB1ET435U 100 Standard two tier block Black AB1ET435U2 6.20 100 + upper-lower link Standard two tier block Green/Yellow AB1ET435UTP 18.60 100 + grounding Standard two tier block Red AB1ET435UBRO 17.10 100 + red 24 V LED Standard two tier block Red AB1ET435UBVE 17.10 100 + green 24 V LED Gray AB1TE 1.10 50 Standard two tier block Orange AB1ET435UBGE 17.10 100 + head to tail diodes (red) 6 mm (0.24 in.) wide Two Tier Blocks Standard two tier block Red AB1ET435UHBRO 10.80 100 Solid or Stranded + diode upper-lower Copper Wire Standard two tier block 2210 AWG Orange AB1ET435UBHGE 10.80 100 + diode lower-upper 300 V 20 A b Standard two tier block Red AB1ET435U2DRO 19.20 100 + 2 diodes Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. o These maximum current values assume the use of insulated copper conductors with 75 C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks.
24
TERMINAL BLOCKS
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
24-6
CP5
Discount Schedule
Table 24.8:
AB1DDP235ULP
10.10
100
AB1DDP235ULM 6 mm (0.24 in.) wide Solid or Stranded Copper Wire 2212 AWG Three Tier Block with ground AB1DDP235T Solid or Stranded Copper Wire 2212 AWG Three Tier Block with 24 V LED (+) and ground Solid or Stranded Copper Wire 2212 AWG Three Tier Block with 24 V LED (-) and ground 6 mm (0.24 in.) wide Solid or Stranded Copper Wire 2212 AWG Three Tier Block Solid or Stranded Copper Wire 2212 AWG Three Tier Block with 24 V LED (+) and ground Solid or Stranded Copper Wire 2212 AWG Three Tier Block with 24 V LED (-) and ground Solid or Stranded Copper Wire 2212 AWG Three Tier Block with ground Solid or Stranded Copper Wire 2212 AWG Gray AB1ET3235U
10.10
100
8.60
100
13.20
13.20
100
8.60
100
AB1ET3235UTLP
27.80
100
27.80
100
AB1ET3235UT
12.60
100
Table 24.9:
Green/ AB1ETNTP435U 12.20 100 Not required for this block. Yellow Solid or Stranded Copper Wire 2210 AWG a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. c One end-barrier is required for each assembly of like blocks.
CP5
Discount Schedule
24-7
24
TERMINAL BLOCKS
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
Block Description Color Without indicator lamp With 512 V LED indicator With 1224 V LED indicator With 110250 V neon indicator Without indicator lamp With 512 V LED indicator With 1224 V LED indicator With 110250 V neon indicator Without indicator lamp With 28 V yellow LED indicator With 250 V yellow LED indicator Gray Gray Gray Gray Gray Gray Gray Gray Gray Gray Gray Catalog Number AB1FUSE435U5X AB1FUSE435U5XJ AB1FUSE435U5XB AB1FUSE435U5XM AB1FUSE435U6X AB1FUSE435U6XJ AB1FUSE435U6XB AB1FUSE435U6XM AB1FU10135U AB1FU10135UB AB1FU10135UU $ Price ea. 7.80 16.10 16.10 16.10 14.40 18.60 18.60 18.60 10.80 26.40 26.40 Std. Pack a 100 50 Color
Fuse Block For 5x20 or 5x25 mm fuse Solid or Stranded Copper Wire 2210 AWG 8 mm (0.31 in.) wide Maximum Voltage600 V Maximum Current15 A b Fuse Block For 1/4 x 1-1/4 in. fuse Solid or Stranded Copper Wire 2210 AWG 10 mm (0.39 in.) wide Maximum Voltage600 V Maximum Current15 A b Fuse Block For 5 x 20 mm fuse Solid or Stranded Copper Wire 226 AWG Maximum Voltage600 V Maximum Current15 A b Fuse Block For 5 x 25 mm fuse Solid or Stranded Copper Wire 226 AWG Maximum Voltage600 V Maximum Current15 A b Fuse Block For 5 x 30 mm fuse Solid or Stranded Copper Wire 226 AWG Maximum Voltage600 V Maximum Current15 A b Fuse Block For 1/4 x 1-1/4 in. fuse Solid or Stranded Copper Wire 226 AWG Maximum Voltage600 V Maximum Current15 A b
Not required for these blocks. 50 50 100 50 Not required for these blocks. 50 50 50 50 50 Gray AB1TF 1.40 50
Gray
AB1FU10235U
14.00
50
Gray
AB1TF
1.40
50
Gray
AB1FU10335U
15.60
50
Gray
AB1TF
1.40
50
Without indicator lamp With 28 V yellow LED indicator With 110500 V red neon indicator
Fuse / Diode block Gray AB1SF435U 3.90 100 Gray AB1PS4 0.86 10 Removable fuse holder Gray AB1SF520 6.50 100 for 5x20 mm fuse Removable fuse holder Fuse / Diode Block for 5x20 mm fuse Gray AB1SF520B 20.30 100 with 24 V red LED indicator Solid or Stranded Copper Wire 2210 AWG Removable fuse holder N/A for 5x20 mm fuse Gray AB1SF520M 20.30 100 Maximum Voltage300 V with 220 V red LED indicator Maximum Current10 A b Removable diode Gray AB1SV1 6.20 100 or resistor holder 6 mm (0.24 in.) wide Removable holder Gray AB1SV2 15.60 100 With 1N4007.1 diode a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article File E164359 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable CCN XCFR2 current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. File 702070 c One end-barrier is required for each assembly of like blocks. Class 6228 01 d For additional information, refer to Catalog 9080CT9901 RoHS Compliant
Table 24.11:
24
TERMINAL BLOCKS DFCC1V
File CNN E310269 IZLT e f
2 Poles
DFCC2
36.00
DFCC3
54.00
12
DFCC1V
22.50
DFCC3V
2 Poles f
DFCC2V
45.00
3 Poles f For additional blocks and information, refer to Catalog 9080CT0801. With blown-fuse indicator.
DFCC3V
68.00
24-8
CP5
Discount Schedule
Table 24.12:
Block for Diodes (Diodes not included) Gray Solid or Stranded Copper Wire 2214 AWG 12 mm (0.47 in.) wide Circuit Isolation Block Solid or Stranded Copper Wire 2210 AWG 6 mm (0.24 in.) wide Maximum Voltage600 V Maximum Current20 Ab Box Lug / Slip-on Block Solid or Stranded Copper Wire 2212 AWG Maximum Voltage300 V Maximum Current10 Ab With two test sockets Box lug on one side. Slip-on access from top and side Box lug on one side. Slip-on access from top Slip-on connectors on both sides Gray AB1SC435U2PT 7.10 50 With no test sockets Gray AB1SC435U 7.10 50 Gray AB1PS4 0.86 10 AB1D11435U 12.50 50 Not required for this block.
Gray Gray
AB1TC01 AB1TC3
1.40 1.40
50 50
Table 24.13:
Lug/Lug Block Solid or Stranded Copper Wire 0 AWG350 kcmil 32 mm (1.26 in.) wide Lug/Lug Block Solid or Stranded Copper Wire 0 AWG 400 kcmil 42 mm (1.65 in.) wide Lug/Lug Block Solid or Stranded Copper Wire 0 AWG500 kcmil 42 mm (1.65 in.) wide Lug/Clamp Block Solid or Stranded Copper Wire 0 AWG350 kcmil 32 mm (1.26 in.) wide Lug/Clamp Block Solid or Stranded Copper Wire 0 AWG400 kcmil 42 mm (1.65 in.) wide
Gray
AB1BB9535
21.30
10
Gray
AB1CT1
2.40
50
Gray
AB1BB18535
27.30
10
Gray
AB1CT2
2.70
50
Gray
AB1BB24035
45.00
10
Gray
AB1CT2
2.70
50
Gray
AB1BC9535
31.10
10
Gray
AB1CT1
2.40
50
Gray
AB1BC15035
62.00
10
Gray
AB1CT2
2.70
50
Lug/Clamp Block Solid or Stranded Copper Wire 0 AWG500 kcmil 42 mm (1.65 in.) wide a b
Gray
AB1BC24035
86.00
10
Gray
AB1CT2
2.70
50
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
CP5
Discount Schedule
24-9
24
TERMINAL BLOCKS
Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks.
Insert wires without stripping Available for wire sizes 30-14 AWG DIN 3 rail mounting Finger safe connections
Table 24.14:
Description
3018 AWG 1814 AWG 3018 AWG 1814 AWG 3018 AWG 1814 AWG 3018 AWG 1814 AWG 3018 AWG 1814 AWG 3018 AWG 1814 AWG 3018 AWG
AB1AA135U2
Insulation Displacement Connector: Grounding Block
AB1AATP135U3
Two Tier Block
600 V 600 V
AB1AAET235
Fuse Block 600 V 6.3 A 3018 AWG
Gray
AB1AASF135UGR
5.00
50
Gray
AB1AAAC123GR
.78
10
AB1AASF135U
600 V
6.3 A
1814 AWG
Gray
AB1AASF235UGR
5.30
50
Gray
AB1AAAC123GR
.78
10
24
TERMINAL BLOCKS
Disconnect Block
600 V a b c
Gray AB1AASC235UGR 6.00 50 Gray AB1AAAC123GR .78 10 Blue AB1AASC235UBL 6.00 50 Blue AB1AAAC123BL .78 10 Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. oC temperature rating and are calculated based on NEC Article These maximum current values assume the use of insulated copper conductors with 75 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. One end-barrier is required for each assembly of like blocks. 10 A 1814 AWG 2
File CCN
E164359 XCFR2
File Class
702070 6228 01
RoHS Compliant
CP5
Discount Schedule
24-10
AB1 Markers
Refer to Catalog 9080CT9901R7/07
Table 24.15:
Markers, AB1
Marking Catalog Number $ Price Std. ea. Pack a Catalog Marking Number A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AB1GA AB1GB AB1GC AB1GD AB1GE AB1GF AB1GG AB1GH AB1GI AB1GJ AB1GK AB1GL AB1GM AB1GN AB1GO AB1GP AB1GQ AB1GR AB1GS AB1GT AB1GU AB1GV AB1GW AB1GX AB1GY AB1GZ $ Price Std. ea. Pack a
Blank AB1BV5 110 AB1B510 1120 AB1B520 2130 AB1B530 3140 AB1B540 4150 AB1B550 0.78 25 AB1B510 5160 AB1B560 6170 AB1B570 Black number on 7180 AB1B580 white background 8190 AB1B590 5 mm (0.20 in.) wide 91100 AB1B5100 Blank AB1BV6 110 AB1B610 1120 AB1B620 2130 AB1B630 3140 AB1B640 4150 AB1B650 5160 AB1B660 6170 AB1B670 0.78 25 7180 AB1B680 AB1B610 8190 AB1B690 91100 AB1B6100 Black number on L1 AB1B6L1 white background 6 mm (0.24 in.) wide L2 AB1B6L2 L3 AB1B6L3 + (Red) AB1BV6RP (Blue) AB1BV6BM Blank AB1BV8 110 AB1B810 1120 AB1B820 2130 AB1B830 3140 AB1B840 0.78 25 4150 AB1B850 AB1B810 5160 AB1B860 6170 AB1B870 Black number on 7180 AB1B880 white background 8190 AB1B890 8 mm (0.31 in.) wide 91100 AB1B8100 Blank AB1RV 1 AB1R1 2 AB1R2 3 AB1R3 4 AB1R4 2 2 2 5 AB1R5 2 2 2 2 2 6 AB1R6 2 2 0.78 25 7 AB1R7 AB1R2 8 AB1R8 9 AB1R9 Black number or symbol 0 AB1R0 on white background 09 AB1R11 + AB1R12 AB1R13 a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity.
1 2 3 4 5 6 7 8 9 10
A A A A A A A A A A
0.78
25
AB1GA
Black capital letters on white background
CP5
Discount Schedule
24-11
24
TERMINAL BLOCKS
10
AB1SR6
0.78
200
AB1SA1
0.18
500
10
AB1SA2
0.39
500
AB1SA3
0.78
500
AB1RT
0.78
500
AR1SB2
1.50
100
AR1SB3
1.35
50
RoHS Compliant
Table 24.17:
Description
$ Price Std.a ea. Pack 0.08 (3) MH203 3.20 0.10 (4) MH204 3.60 0.13 (5) MH205 4.10 0.15 (6) MH206 4.70 0.18 (7) MH207 5.10 0.20 (8) MH208 5.60 0.23 (9) MH209 6.20 0.25 (10) MH210 6.80 Galvanized 0.28 (11) MH211 7.20 steel, 0.30 (12) MH212 7.80 no mounting 0.33 (13) MH213 8.30 holes 0.36 (14) MH214 8.70 0.38 (15) MH215 9.30 0.41 (16) MH216 9.80 0.42 (17) MH217 10.20 0.46 (18) MH218 10.80 0.50 (19.68) MH220 11.60 Symmetrical rail 1 (39.37) MH239 19.70 35 x 7.5 mm 2 (78.74) MH279 29.60 (1.38 in. x 0.295 in.) 10 in compliance with 0.08 (3) MH303 3.50 EN 50022 standard 0.10 (4) MH304 3.90 (DIN 46277-3). 0.13 (5 in. MH305 4.70 0.15 (6) MH306 5.10 0.18 (7) MH307 5.70 0.20 (8) MH308 6.20 0.23 (9) MH309 6.90 0.25 (10) MH310 7.40 0.28 (11) MH311 8.10 Galvanized steel, 0.30 (12) MH312 8.60 prepunched 0.33 (13) MH313 9.20 0.36 (14) MH314 9.60 0.38 (15) MH315 10.20 0.41 (16) MH316 10.80 0.42 (17) MH317 11.60 0.46 (18) MH318 12.00 0.50 (19.68) MH320 13.10 1 (39.37) MH339 23.00 2 (78.74) MH379 32.70 High rise track Aluminum 1 (39.37) MH439 27.90 2 a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. Description
7.5 mm depth, 1 mm steel, zinc chromated EN 50022 & NF C63-015 2 (78.74) AM1DP200 7.80 10
2 (78.74)
DZ5MB201
23.20
10
15 mm steel, zinc chromated DIN 2 Symmetrical 15 mm track EN 50045 1 (39.37) AB1PC15 7.50 10
Dimensions
.98 .98 .98 25 25 25 .04 1
1.38 35
78.74 2000
1.06 27
.06 2 .59 15
1.38 35
.49 12 78.74 2000 .28 7 .59 15
1.06 27
.30 8
Dimensions
AM1DE200
.98 25 .25 6
AM1ED200
.71 18
.30 8
1.80 46 1.17 30
.04 1
1.38 35
.49 12 78.74 2000 .28 7 .04 1
1.06 27
.30 8
AM1DP200
9080MH3**
9080MHA10
Catalog Number $ Price Std.a Pack ea.
.20 5
.24 6
.59 15
For mounting 9080GH or MH track to a panel at 45o angle. Includes 2 brackets and hardware for mounting the track to the brackets. End Clamps Plastic end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide
AB1PC15
9080MH82c 7.20 1 End Clamps
DZ5MB201
Catalog Number $ Price ea. Std.a Pack
24
TERMINAL BLOCKS
AB1AB8P35
1.50
100
Plastic end clamp for 32 mm DIN 1 track, 7.5 mm (0.30 in.) wide
AB1AB7P32
2.60
100
AB1AB8M35
2.40
100
Metal end clamp for 32 mm DIN 1 track, 7.5 mm (0.30 in.) wide
AB1AB10M32
2.60
100
Polycarbonate end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide b Not RoHS Compliant
9080MHA10
2.40
50
Plastic end clamp for 15 mm DIN 2 track, 7.5 mm (0.30 in.) wide
AB1AB715
1.50
100
AB1AB8R35
1.50
100
RoHS Compliant
24-12
CP5
Discount Schedule
Type G
Class 9080 / Refer to Catalog 9080CT9601
Table 24.18:
Description
Selection Guide
Maximum Maximum Voltage Currentb Blocks Color Natural Black Blue Green Gray Orange Red Yellow Brown Type GR6 GRB6 GRL6 GRG6 GRE6 GRS6 GRR6 GRY6 GRN6 $ Price ea. Std. Packa Type GM6B GMB6B GML6B GMG6B GME6B GMS6B GMR6B GMY6B GMN6B End Barriersc $ Price ea. Std. Packa Blocks per ft Max. Wire Combinations Copper Wire (stranded or solid)
Solderless Box Lug for #22 to #8 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. 600 V 60 A
2.40
50
0.78
10
34
Similar to a 9080GR6 except with a 9080GH91 banana test plug adapter installed. Fingersafe per DIN 57470.
600 V
60 A
Natural
GR6T
2.90
50
GM6B
0.78
10
Solderless Box Lug for #22 to #10 AWG wire. Can be mounted directly to a panel or can be mounted on 9080GH track. 600 V 40 A
Natural Black Blue Green Gray Orange Red Yellow Natural Black Blue Green Gray Orange Red Yellow Brown
GK6 GKB6 GKL6 GKG6 GKE6 GKS6 GKR6 GKY6 GM6 GMB6 GML6 GMG6 GME6 GMS6 GMR6 GMY6 GMN6
2.40
50
GK6B
0.93
50
34
High Density Solderless Box Lug for #22 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. 600 V 30 A
1.80
50
0.78
10
51
Solderless Box Lug for #18 to #4 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. 600 V 85 A Natural GC6 5.00 50 GC6B 1.30 10 28
1 #4 1 #6 12 #8 14 #10
Solderless Box Lug for #12 to #1/0 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. 600 V 170 A Natural GD6 10.10 10 GD6B 1.70 10 17
1 1/0 1 #1 1 #2 12 #4
13 #6 15 #8 16 #10 17 #12
Solderless Box Lug for #6 AWG to 250 kcmil wire. d Mounts on standard 9080GH track or 35 mm DIN 3 track. 600 V 255 A Natural GE6 27.00 10 None Required 10
a b
c d
Orders must specify standard package quantity or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. The lower of the UL and CSA ratings are shown. One end-barrier is required for each assembly of like blocks. Terminals are tin plated, making them suitable for use with either copper or aluminum wire.
File CCN
E60616 XCFR2
File Class
025490 3211 07
For Standard or Custom Assemblies . . . . . . . . . . . . . . . . . . . . . . page 24-15 For Mounting Track and Accessories . . . . . . . . . . . . . . . . . . . . . . page 24-16 For DIN 3 track and end clamps . . . . . . . . . . . . . . . . . . . . . . . . . . page 24-12
CP5
Discount Schedule
24-13
24
TERMINAL BLOCKS
Type G
Class 9080 / Refer to Catalog 9080CT9601
www.schneider-electric.us
Blocks per ft
Max. Wire Combinations Copper Wire (stranded or solid) 1 or 2 1 or 2 1 or 2 1 or 2 #12 #14 #16 #18
Self-Lifting Pressure Wire Connector for #18 to #12 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track.
600 V
40 A
GP6
2.60
50
GP6B
1.00
10
32
Flat Terminal Connector for #22 to #12 AWG wire. Screws are #6-32 x 5/16 in. for ring or spade lugs, 5/16 in. wide maximum. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470.
600 V
40 A
GA6
1.80
50
GP6B
1.00
10
32
Circuit Isolating Switchd with self-lifting pressure connectors for #18 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track.
600 V
30 A
GG6
18.00
10
GF6B
4.80
10
16
1 1 1 14 14
Slip-on Connectors for #22 to #12 AWG wire. Tabs accept 0.250 x 0.032 in. slip-on connectors Mounts on standard 9080GH track or 35 mm DIN 3 track.
600 V
20 A
GS6
4.80
10
GF6B
4.80
10
16
12 12 12 12 12 12
Transient Voltage Suppressorsf with box lug connectors for #18 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track.
120 V
GT6
20.70
GT6B
1.70
10
24
1 1 1 12 14
Fuse Block for 13/32 in. Dia. x 1-1 2 in. ferrule fuse with self-lifting pressure connectors. Fuse puller is included as standard. Fuses are not included. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470.
600 V
30 A
GF6
11.70
10
GF6B
4.80
10
16
1 1 1 14 14
Fuse Pullere
GH63
2.40
50
N/A
N/A
N/A
Blown Fuse Indicator/ Pullers are neon pilot lights which plug on to the fuse in a standard Type GF6 fuse block.
120240 V
GLP3
11.90
10
277600 V
GLP6
11.90
10
N/A
a b
c d e
Orders must specify the standard package quantity or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. The lower of the UL and CSA ratings are shown below. One end-barrier is required for each assembly of like sections. Not intended to make or break a live circuit. Power must be disconnected from the circuit before operation of the switch. Fuse puller is supplied as standard with Class 9080 Type GF6 fuse block. The 9080GH63 is a replacement fuse puller.
VOLTS
Modules have RC circuitry for suppressing transient voltage, generated when opening a coil circuit, to approximately 200% of the peak line voltage, when used with 120 V coils. Type GT6 is suitable for use with Square D Class 8501 Type X, K, R and C relays or Square D Type S starters and contactors, Sizes 00-2.
24
TERMINAL BLOCKS
300
Terminal Blocks File CCN File Class E60616 XCFR2 025490 3211 07
0
TIME
Table 24.20:
To Order Specify
How to Order
Catalog Number Class 9080 Type GP6
Blown Fuse Indicator File CCN File Class E63698 JDV5 025490 3211 07
For Standard or Custom Assemblies page 24-15 For Mounting Track and Accessories page 24-16 For DIN 3 track and end clamps page 24-12
24-14
CP5
Discount Schedule
Type G
Class 9080 / Refer to Catalog 9080CT9601
Description Assembly of 188 Type GA6 Assembly of 204 Type GR6 Assembly of 94 Type GF6 Assembly of 296 Type GM6 Assembly of 188 Type GP6
Table 24.23:
Option Suffix Example Substitute slip-in end clamps C 9080GR625C Substitute snap-off channel B 9080GR625BC a For direct mount assembly of 9080GK6 blocks D 9080GK67D Add a blank vinyl marking strip M 9080GR625M Add pre-marked (125 only) marking strip MPO 9080GR625MPO Mount on 35 mm DIN 3 track instead of T 9080GR625T 9080GH track a The 9080GH10 screw-on end clamp is not recommended for use with snap-off channel. It is recommended that the 9080GH11 slip-in end clamp be used. Therefore, when the suffix B is used, it should be followed by the suffix C.
$ Price per block from Table 24.22 Number of blocks in the assembly x Subtotal (multiply # of blocks by price of blocks) Initial Charge for factory assemblies All except 9080GK6 direct mount ($7.00) OR for 9080GK6 direct mount ($3.60) Vinyl Marking Strips Adder for Suffix M$0.05 per block OR adder for Suffix MPO$0.24 per block Deduct for Suffix C$2.40 Total everything from Subtotal down Apply the following rounding rules to the total obtained: $1.00 through $50.00 over $50.00
Table 24.24:
To Order Specify
How to Order
Catalog Number Class 9080 Type GA612
CP5
Discount Schedule
24-15
24
TERMINAL BLOCKS
Type G
Class 9080 / Refer to Catalog 9080CT9601
www.schneider-electric.us
Table 24.27:
$ Price Std. ea. Packa 3 GH103 2.40 5 4 GH104 2.40 5 5 GH105 2.60 5 6 GH106 2.60 5 7 GH107 2.60 5 8 GH108 3.00 5 9 GH109 3.00 5 10 GH110 3.30 5 11 GH111 3.30 5 Standard 12 GH112 3.50 5 Track 13 GH113 3.50 5 14 GH114 3.80 5 Snap-Off Standard 15 GH115 3.90 5 Track Track 16 GH116 4.20 5 17 GH117 4.40 5 18 GH118 4.80 5 36 GH136 11.70 5 48 GH148 15.20 5 72 GH172 22.70 5 36 GH236 11.70 20 Snap-Off High Rise 48 GH248 15.20 20 Track 72 GH272 22.70 20 High Rise 36 GH336 29.00 2 Note: For additional track and appropriate end clamps, see page 24-12.
11.90
5 5 5
For GM6
Blank pin-feed marking tabs6 x 20 (total 120) marking tabs GH200 for GD6, GR6, and GT6 blocks
1.70
20
Pre-marked 01 to 50 (2 sets) plus 20 Various marking tabs (total 120 marking tabs) GH210 for GD6, GR6, and GT6 blocks
13.10
Table 24.26:
Accessories
Description Type $ Price Std. ea. Packa
GH40
8.00
12
End Clamps Screw-on End Clamp (Not recommended for use on snap-off mounting track)
Marking strip end plug for GK6, GR6, GM6, GA6, GP6, GC6, GD6, GE6, and GT6 blocks GH10 2.40 50
GH60
.39
50
Slip-in End Clamp (Not for use with 9080 GE6, GK6 blocks) Jumpers 2-pole jumper for GM6 6-pole jumper for GM6
GH11
.63
50
GH61
.98
50
GH700 GH710
.59 1.20 .62 1.80 2.30 4.30 3.20 8.70 1.20 2.00
20 10 20 10 10 10 10 10 10 10
.98
50
2-pole jumper for GK6, GR6 GH72 6-pole jumper for GK6, GR6 GH73 2-pole jumper for GC6 6-pole jumper for GC6 2-pole jumper for GD6 6-pole jumper for GD6 GH74 GH75 GH76 GH77
GH90
7.40
10
2-pole jumper for GA6, GP6 GH78 6-pole jumper for GA6, GP6 GH79 Fanning Strip
Test plug adapter for GR6T block (included as standard with GR6T) Angle bracket kitfor mounting 9080GH or MH track to panel at 45 angle. Includes 2 brackets and hardware for mounting the track to the brackets Polycarbonate end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide
GH91
1.20
50
GH51
3.00
10
MH82
7.20
24
Snap-together fanning strip GH52 section for GK6, GR6 blocks 3.30 10
MHA10
2.40
50
TERMINAL BLOCKS
Orders must specify the standard package quantity or multiples of that quantity.
Table 24.28:
To Order Specify
How to Order
Catalog Number Class 9080 Type GH10
24-16
CP5
Discount Schedule
Type GCB
Class 9080 / Refer to Catalog 9080CT9901
Table 24.29:
GCB100
Internal Resistance Maximum Voltage Catalog Numbera $ Price 0.1 133 GCB01 0.5 6.6 GCB05 0.8 2.55 GCB08 66.00 1.0 1.97 GCB10 1.2 1.22 GCB12 1.5 0.86 GCB15 250 Vac 65 Vdc 2.0 0.49 GCB20 2.5 0.31 GCB25 3.0 0.20 GCB30 4.0 0.10 GCB40 72.00 5.0 0.08 GCB50 7.0 0.03 GCB70 10.0 <0.02 GCB100 125 Vac 65 Vdc 15.0 <0.02 GCB150 o These maximum current values assume the use of insulated copper conductors with 75 C temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. Discount schedule CP5. Maximum Current (A)
Selection
To properly select a Class 9080 Type GCB circuit protector, follow these steps:
Table 24.30:
1. 2. 3. 4.
Determine the inrush correction factor from Table 24.30. Determine the temperature correction factor from Table 24.31. Determine the sealed current of the load that is being protected. Multiply the sealed current by the two correction factors and choose the closest circuit protector.
Note: For resistive loads, use inrush correction factor of 1.0. Inrush Ratio 1:1 to 1:4 1:5 1:6 Factor 1.3 1.4 1.5
Table 24.31:
Ambient Temperature Factor
Note: Choosing a circuit protector with a value lower than the calculated value might cause nuisance tripping, while choosing the larger might provide a protector that will not properly protect the load. File CCN File Class E152841 QVNU2 025490 3211 07 Example: Solenoid with sealed current of 0.75 A, an inrush ratio of 1:6, and in an ambient temperature of 85oF: 0.75 x 1.5 x 1.05 = 1.18 Choose the 1.2 A protector Tripping Time: Tripping time of the circuit protector is determined from Table 24.32. Divide the circuit protector value by the temperature correction factor from Table 24.31 to determine actual rated current referenced in Table 24.32.
(21.1 C) 1.0
Table 24.32:
Percent rated current Tripping Time (s)
Note: When several protectors are channel mounted adjacent to each other, the no trip current will be 80% of rated current at 70oF.
CP5
Discount Schedule
GB2CB06
8A 10 A 12 A
c Discount schedule I. d Must order in multiples of 6 Note: For markers, use AB1( )R and AB1( )G markers from page 24-16
File Class
081630 3215 30
File CCN
E113720 QVNU2
GB2CD
Discount Schedule
24-17
24
TERMINAL BLOCKS
GB2CD20
Type LB
Class 9080 / Refer to Catalog 9080CT9603
www.schneider-electric.us
These Power Distribution Blocks are listed to UL1953 and meet the feeder spacing requirements of UL508A. They carry a short circuit current rating (SCCR) according to the requirements of the 2005 National Electric Code (NEC and UL580A. For SCCRs, refer to the catalog, 9080CT9603R9/08. Table 24.34: Wire Range and Current Ratings
Wire Range AWG/kcmil Line 2/014 2/014 2/014 2/014 4006 6002 6002 Load (4) 4 -14 2/0 -14 1/4 - 20 stud (6) 4 -14 (6) 2 -14 (3) 1/0 -14 (6) 2 -14 (12) 4 -14 Current Amps CU 175 175 175 175 335 335 335 AL 135 135 135 135 270 335 335 $ Price 98.00 83.00 90.00 105.00 180.00 263.00 270.00
Catalog LBFA368104 LBFA368101 LBFA368101S LBFA368106 LBFA369106 File E323110 File 244651 Class 6228-01 CCN QPQS LBFA369136 LBFA369112
Table 24.35:
Lug Wire Rangea Main (1) #142/0 (1) #6350 kcmil (1) #4600 kcmil (2) #4350 kcmil (2) #6500 kcmil (1) #142/0 (1) #142/0 (1) #6400 kcmil (1) #6400 kcmil (1) #6400 kcmil (1) #4500 kcmil (1) #4500 kcmil (2) #142/0 (2) #6500 kcmil (2) #6500 kcmil Branch (1) #142/0 (1) #6350 kcmil (1) #4600 kcmil (2) #4350 kcmil (2) #4500 kcmil (4) #144 (6) #144 (4) #142 (6) #142 (8) #142 (6) #142/0 (12) #142 (6) #144 (8) #142/0 (12) #144
LBA365212
Table 24.36:
Lug Wire Rangea Main (1) #142 (1) #142 Branch (1) #142 (4) #1810
LBA161104
Table 24.37:
LBC165212
(1) #181/0 (1) #181/0 LBC162101 99.00 N/A (1) #6250 kcmil (1) #6250 kcmil LBC163101 125.00 N/A (1) #142/0 (4) #144 LBC162104 99.00 LBC262104 (1) #4500 kcmil (6) #142 LBC163106 153.00 LBC263106 (2) #142/0 (6) #144 LBC163206 134.00 LBC263206 (2) #4500 kcmil (8) #142/0 LBC165208 297.00 N/A (2) #6500 kcmil (12) #142 LBC165212 284.00 N/A a Lugs suitable for use with 75oC conductors. (#) indicates number of conductors. b Aluminum blocks will accept either Al or Cu conductors. c Cu blocks will accept copper conductors only.
LBC362101 201.00 LBC363101 233.00 147.00 LBC362104 248.00 228.00 LBC363106 354.00 201.00 LBC363206 269.00 LBC365208 593.00 LBC365212 567.00 d CE Marked. e Refer to catalog for dimensions. f UL component recognized (File E60616 CCN XCFR2). CSA certified (File LR70361, Class 070361).
24
Table 24.38:
TERMINAL BLOCKS
Application Data
Voltage RatingClass B & C600 V Blocks are rated based on NEC Table 310-16 using 75oC wire. Aluminum blocks are tin plated high conductive aluminum. Copper blocks are tin plated high conductive copper. Housing material:
Note: There are no covers for miniature blocks. For LBA Type Type $ Price ea. g LBA162, LBC162 LB21 11.30 LBA262, LBC262 LB22 13.50 LBA362, LBC362 h LB23 15.80 LBA163, LBC163 LB31 12.50 LBA263, LBC263 LB32 14.70 LBA363. LBC363 LB33 17.00 LBA164 LB41 13.50 LBA264 LB42 15.80 LBA364 LB43 18.00 LBA165, LBC165 LB51 14.70 LBA265, LBC265 LB52 17.00 LBA365, LBC365 g h LB53 19.20
Miniature Blocks are made from high impact thermoplastic rated at 125oC. max. & -40oC. min. Full Size Blocks are made from general purpose phenolic rated at 150oC. max. & -40oC. min.
All blocks have a flammability rating of UL 94V-0. Most blocks have a short circuit current rating for UL508A up to 200 kA for branch circuit applications. For the actual ratings, see catalog 9080CT9603R9/08. RoHS Compliant
These covers must be ordered in multiples of 5. Each cover comes with two self-tapping screws. Will not work on a 9080LBA362106 block.
24-18
CP1
Discount Schedule
Fuseholders
www.schneider-electric.us
Type FB
Class 9080 / Refer to Catalog 9080CT9603
Table 24.39:
Rating (A) f 30a No. of Poles 1 2 3 1 2 3 1 2 3
60a
100b
FB2221
FB3221R
Table 24.40:
Rating (A) f 30b No. of Poles 1 2 3 1 2 3 3
Table 24.42:
Rating (A) f 30b 100b
60b 100b
147.00 FB3631R
Table 24.41:
Rating (A) f 30a No. of Poles 1 2 3
Table 24.43:
Rating (A) f 30bg
600 VClass J
No. of Poles 1 2 3 1 2 3 Class J Type FB1611J FB2611J FB3611J FB1621Je FB2621Je FB3621Je $ Price 26.00 45.50 63.00 32.00 54.00 75.00 Lug Wire Range #214 AWG CuAl #214 CuAl
60b
Application Information:
Base material:
a b c Base is high impact thermoplastic maximum operating temperature 125oC Base is general purpose phenolic maximum operating temperature 150oC Base is high impact polyester maximum operating temperature 130oC
Table 24.44:
Track Adapter
Description Type $ Price Std. ea. Pack h
Clip material:
All 30 and 60 A fuse clips are copper alloy tin plated. All 100 and 200 A fuse clips are one piece aluminum with copper spring tin plated. All Class H, R and J fuses are standard with reinforced fuse clips. All 30 A blocks have pressure wire connectors. All 60, 100 and 200 A blocks have box lug connectors. The Type M fuseholders are UL component recognized (File E40747 CCN IZLT2). The Type H, R, J and CC are UL Listed (File E40747 CCN IZLT). All fuseholders are CSA certified (File 70360 Class 6225-01).
35 mm DIN 3 Track Adapter For 9080 FB*211, FBDIN3 FB*211R, e FB*611M, and FB*611CC Fuseholders
4.10
100
Table 24.45:
A 30 60 100 200 d
Lug termination:
Approvals:
Class H/R Class H/R Class M/CC Class J600 V 300 V 600 V 600 V 9/16 x 2 in. 13/16 x 5 in. 13/32 x 1-1/2 in. 13/16 x 2-1/4 in. 13/16 x 3 in. 1-1/16 x 5-1/2 in. N/A 1-1/16 x 2-3/8 in. 1 x 7-7/8 in. N/A N/A 1 x 7-7/8 in. 1-1/2 x 7-1/8 in. 1-3/4 x 9-5/8 in. N/A N/A
Class R and CC fuseholders accept current limiting Class R & CC fuses only. e Not in stock. Order pointRaleigh, NC. f Specified wire ranges are based on 75oC wire. Wires with temperature ratings other than 75oC are approved while observing NEC Article 310 wire tables for allowable ampacities of insulated conductors. Class R, J and CC fuse blocks are tested and approved for 200,000 AIC in accordance with UL 512. g Can be mounted directly to a panel or on 35 mm DIN 3 track. h Orders must specify the standard package quantity or multiples of that quantity. Sold in standard pack quanties.
Table 24.46:
To Order Specify
How to Order
Catalog Number Class 9080 Type FB1211
CP1
Discount Schedule
24-19
24
TERMINAL BLOCKS
Cable Ends
Strip the wire, insert it into the cable end and crimp it. Up to 7 markers can be used.
Table 24.47:
Wire Size AWG 26 24
DZ5CE005
22
0.50
White
20
0.75
Blue
B C A D
18 1.00 Red
16 14 14 12 10
DZ5CA007
Table 24.48:
26 24 22
B C D
20 18 16 14
22
Table 24.49:
12 10
DZ5CA042
2 B C D 4.5 D
8 6 4 2
A
0
Table 24.50:
24
AZ5DE010 TERMINAL BLOCKS
B C A D E
a b c d e
22 20 18 16
13
14 2.50 Gray 24 10 2.7 4.2 7.8 AZ5DE025 0.32 250 Bold faced catalog numbers are stocked in the United States. These catalog numbers are UL Component Recognized (File E164872 CCN ZMMT2) provided the AT1PA crimping tool is used to crimp the cable end. CE Marked. Order must specify the standard pack quantities or multiples of that quantity. Will accept an AR1SC03 cable marker from page 24-22.
RoHS Compliant
24-20
Discount Schedule
Cable Ends
www.schneider-electric.us
AR1SC01
AR1SC02
AR1SC03
Table 24.52:
Description
Cable end marker positioning tool Automatic stripping and cutting tool for 0.8 mm to 4 mm cable, AT1PA7 adjustable stripping length 2 2 Crimping tool for cable ends 0.5 mm to 16 mm AT1PA2 AT1PA4 Crimping tool for cable ends 10 mm2 to 35 mm2 Organizing case for cable endsholds AT1HB2 stripping tool and cable ends (not supplied) a Order must specify the standard pack quantities or multiples of that quantity. b Complete the catalog number by adding the number or letter desired. Examples: AR1 MA015 is a card of 200 yellow markers with a black 5 marked on them. R1 MB01T is a card of 200 yellow markers with a black T marked on them.
AT1PA1
AT1PA7
AR1MA019
Discount Schedule
24-21
24
TERMINAL BLOCKS
The TELEFAST 2 system is a set of products for the rapid connection of I/O modules (24 Vdc discrete, analog and counters) to Various control circuit components. These components act as a substitute for screw terminal blocks, remotely locating and partly eliminating the single wire connections. The system connects only to channels with HE10 and SUB-D connectors, or to standard terminal blocks with a cabled connector. Variations within the listing of modules include those with and without relays (electromechanical and solid state), analog and counter modules, and special function modules. Pre-wired cables available allow you to connect directly to:
Schneider Electric (Modicon family) TSX Premium TSX Micro TSX Series 7 Twido Quantum Compact April S5000/7000 NUM1020/1060 Siemens S7 200/300/400 S5 95U to 155U Allen-Bradley SLC500 I/O simulators Continuity blocks Label marking software Splitter bases (16, 23, and 32 channels) Mounting kits Detachable terminal strips Wiring pass-through connectors Fuses
35 mm DIN-rail Mounting
Custom Labeling of Channels (cover face) and Wiring Diagram (under cover)
24
TERMINAL BLOCKS
24-22
Table of Contents
Section 25
Safety PLC
XPSMF Safety PLC for use in safety systems where multiple functions are required, or where the interaction between the various components of the safety system is more complicated. MACHINE SAFETY PRODUCTS
25-4
Safety Controller
XPSMC safety controllers for use where multiple safety relays and multiple safety functions are required, or where there is a greater interaction between the various safety functions required on the machine.
25-4
XPS safety relays for controlling individual safety functions of the system. XPSMC Safety Controller (p. 25-4)
25-5
25-5
Light Curtains
XUSL light curtains for use in point of operation guarding and perimeter guarding. Available in 14 mm (finger) or 30mm (hand) minimum object sensitivity (MOS) as well as perimeter or body detection, all with a wide range of protected heights.
25-6
25-7
25-7
25-8
25-8
Palm Operators
9001 Type P palm operators for applications such as power operated presses, and two hand control applications.
25-1
25
Safety Relays
Introduction
Class 9007 / Refer to Catalog MKTED208051EN-US
www.schneider-electric.us
Safety systems are comprised of many components, and no one safety component will ensure the safety of the system. The design of the complete safety system and level of safety desired must be considered before choosing products. The whole safety system needs to be integrated as part of the initial design, not added on after the machine is built. Schneider Electric can provide a wide range of products for the protection of personnel for machine guarding applications and safety system architectures.
25
MACHINE SAFETY PRODUCTS
Safety PLCsXPSMF
Safety PLCs are used where the safety solution is complicated, or where there are a greater number of safety inputs or outputs required. They are also used where safety inputs and outputs need to be distributed around the machine or production area.
Safety ControllersXPSMC
Safety controllers are used in applications where multiple safety relays would be required to control the safety system, or where the interaction between the individual safety relays would require significant inter-wiring. The simple-to-use software allows the user to easily develop the safety control system, providing a cost effective solution.
Palm Buttons9001 P
Press applications demand two hand control units for operator protection that are large and easy to operate while wearing gloves. Other press applications, such as stop and inch, also need large buttons for operators wearing gloves. The 9001 P palm buttons offer a variety of operators to meet these needs.
Safety RelaysXPS
To tie the whole safety system together, XPS safety relays are used to monitor the safety inputs, outputs, and feedback from the system to determine when the system is safe to start and when the system should be shut down.
Light CurtainsXUSL
Some machine operations may not allow gates or guards to be used, and other applications require high visibility of the process or easy accessibility. For these applications, XUSL light curtains may be the best choice and are available in many protected heights, minimum object sensitivities, and configurations.
25-2
Safety Architectures
Class 9007 / Refer to Catalog MKTED208051EN-US
www.schneider-electric.us
Local diagnostics (LEDs) Remote diagnostics (solid-state outputs) Plug-in connectors simplify maintenance Select only the safety functions needed Simple installation Simple replacement Proven electromechanical reliability No software to learn or use
Increased productivity because of: Reduced machine down time Reduced overall engineering costs incurred during installation and maintenance Reduced system complexity by having a single network solution instead of many XPS-MF will simplify the entire system by: Saving space Reducing wiring Increasing overall system flexibility by use of programming and device placement (network capability) Providing complex diagnostics (network capability) Saving time and money due to reduced maintenance SafeEthernet protocol
AS-Interface
Provides diagnostics without additional wiring Lowers costs from design to operation All of our machine safety productssuch as safety interlocks, light curtains, and cable pull switchescan be used with any of the safety devices listed above. The final safety control system could meet the safety levels indicated in Table 25.1, depending upon how the safety circuit is designed. Table 25.1: Maximum Safety Levels of the Safety Architecture
Category 4 per EN 954-1 and ISO 13849-1 XPS Safety Relays XPSMC Safety Controllers XPSMF Safety PLCs AS-Interface Safety at Work Yes Yes Yes Yes SIL 3 Per IEC 61508 No Yes Yes Yes
25-3
25
Many different safety architectures are available in Schneider Electric's product offering, from safety relays to safety PLCs. The safety architecture can determine what SIL level or safety category can be achieved with the safety solution. Various architectures may have inherent benefits such as simple selection or increased levels of diagnostics, but their cost effectiveness can depend on the size and complexity of the safety system and the features and functions required. Some of the features and benefits of these Various architectures are:
25
MACHINE SAFETY PRODUCTS
XPSMF PLC
The XPSMF Safety PLCs are programmable logic controllers that can be interfaced with the machine control system to meet US, EN, and IEC safety requirements. All XPSMF Safety PLCs meet the requirements of SIL 3 per IEC 61508, Category 4 per EN 954-1 and ISO 13849-1, and performance level e per ISO 13849-1.The XPSMF can perform all of the various safety functions required in todays machinery. These functions can be programmed by using one or more pre-defined and certified function blocks (CFB) or by creating your own configuration and function blocks. Features and Benefits
The XPSMC safety controllers can be used for monitoring all of the different safety tasks for your applications in one safety controller. All of the functions of the various safety relays are built into the hardware and software. The XPSMC safety controllers meet SIL 3 per IEC 61508, Category 4 per EN 954-1 and ISO 13849-1, and performance level e per ISO 13849-1. The associated configuration software makes development of the safety solution simple, using drag and drop techniques to configure the safety system. Detailed diagnostics provide an in depth overview of the status of the inputs and outputs. Features and Benefits
Increased productivity because of: Reduced machine down time Reduced overall engineering costs incurred during installation and maintenance Reduced system complexity by having a single network solution instead of many Saving space, reducing complexity Reducing wiring Increasing overall system flexibility by use of programming and device placement (network capability) Providing complex diagnostics (network capability) Saving time and money due to reduced engineering and maintenance Certified to SIL 3 per IEC 61508, Category 4 per EN 954-1 and ISO 13849-1, and performance level e per ISO 13849 -1, UL/CSA Each Safety PLC contains two processors (redundancy) SafeEthernet protocol Standard bus communication using Ethernet 2 or 4 RJ45 connection points (depending on version) Connect hardware in any orientation LED diagnostics on PLC housing Removable terminals Compact range contain DIN rail attachment simplifying installation
Safety inputs 16 or 32 safety inputs Safety outputs Six safety semiconductor outputs Two safety relay outputs, with two relay contacts each (for a total of four relay outputs) One output for muting indicators
Control outputs Eight control outputs are used to supply the safety inputs in order to detect incorrect wiring or short circuits in the wiring. Configuration Software
Hardware
The wide device library of certified safety functions simplifies the development of safety applications. Using the simple to use XPSMCWIN software, the configuration can be developed without special training. Diagnostics with PC and Software Using the diagnostics mode, the XPSMCWIN software provides an exhaustive overview about the status of the safety functions. The status of the inputs, the safety devices and the outputs are indicated by various colored indicators. Diagnostics with LEDs in the Front Cover
6 LEDs indicate the status of the controller. 8 LEDs indicate the status of the safety outputs. 16 or 32 LEDs indicate the status of the safety inputs. Input/output errors are indicated by blinking of the corresponding LED.
25-4
ASISAFEMON1B Monitor
XPS safety relays monitor various safety inputs, start sequences, and feedback from starters and relays to allow machinery operation only when all safety controls are in their appropriate state and are functioning properly. Inputs can be from emergency stop push buttons, cable pull switches, limit switches, light curtains, safety interlock switches, or two hand control stations. XPS safety relays give users increased functionality and flexibility when designing equipment to meet safety requirements and standards in the U.S., for the European Safety Directive, IEC safety requirements and meet Category 4 of EN 954-1 and ISO 13849-1. Most devices can be configured for single or dual channel inputs, and for either monitored start, non-monitored start, or automatic start. Removable wiring terminals or non-removable wiring terminals are available on most module types. The XPS product family complements our broad safety product offering with modules for many specific safety functions and applications, as well as devices for use in general types of applications. There are even devices whose safety functions can be configured at the time of installation. PREVENTA XPS Includes the Following Types of Safety Relay Modules: Specific purpose modules such as limit switch monitoring, zero speed, timing, two-hand control, press control, and others Multifunctional configurable devices with multiple sets of inputs whose functions can be configured from 15 pre-defined functions, allowing greater flexibility and functionality Broad range of devices for emergency stop applications Expansion modules to increase the number of safety outputs Many devices compatible with light curtains Features and Benefits
AS-Interface, the recognized cabling system for sensors and actuators, has been enhanced. Standard process information and information relating to safety can now be transmitted over the same yellow cable. Certified to SIL 3 per IEC 61508, Category 4 per EN 954-1 and ISO 138491, and performance level e per ISO 13849-1, the ASInterface Safety at work system meets the needs of the most common safety applications, such as: Monitoring of emergency stops with instantaneous break contacts (stop category 0) Monitoring of emergency stops with delayed break contacts (stop category 1) Monitoring of safety interlocks and limit switches with and without interlocking Monitoring of light curtains Features and Benefits
Simplicity Just add the required safety devices to the standard AS-Interface network. Integration Standard data and safety relevant data is transmitted over the same communication busno need for a separate safety network. Flexibility Monitor multiple devices and control multiple safety sectors. Diagnose From one screen, see the status of the safety interfaces and the system. Safety Category 4 per EN 954-1 and ISO 13849-1 SIL 3 per IEC 61508 Multifunctional Monitor up to 31 safety interfaces. Available with 1 or 2 independent output groups. Segmentation of safety sectors Multiple safety monitors can be connected to the same AS-Interface network. Monitors can be configured to monitor different groups of safety interfaces.
LEDs are provided to indicate power, input, output, and feedback loop status. Solid state outputs provide compatibility with system controllers for diagnostics, troubleshooting, and correct system operation. Most devices are available with either removable or non-removable terminals. Most devices are available with a monitored start function to detect welded contacts or incorrect status in the start function and also to detect tampering with the start circuit. Dual voltage devices are available for use with either 120 V or 24 V power to reduce your inventory and increase flexibility.
45 mm wide housing ASISWIN2 Configuration Software Drag and drop methodology Predefined, certified safety functions for user selection On-line diagnostics of AS-Interface Safety System Password protection
25-5
25
Light Curtains
XUSL Type 4 light curtains provide point of operation protection for large areas without the need for gates or guards. They allow excellent visibility of the machine or process and free access to the machine while providing protection for personnel. Light curtains are made up of an array of infrared light beams to form a protected area. Whenever one or more of the light beams is broken, the light curtain sends a stop signal to the machine safety control circuit. XUSLB and XUSLD light curtains for point of operation safeguarding are available in either single or multiple segment configurations. Choose the one that best meets your application requirements. These versions are available in either 14 mm or 30 mm minimum object sensitivity (MOS). Fixed and floating blanking is standard on the XUSLD. XPSLP perimeter guard light curtains detect the presence of a body as it enters a protected area. They are available in single or multiple beam systems.
25
MACHINE SAFETY PRODUCTS XUSLB and XUSLD Light Curtain XUSLP Light Curtain XUSLP Light Curtain
Slim and rugged design results in an esthetically pleasing small mounting footprint suitable for aggressive environments. Broken Beam Indicators for EVERY beam on ALL devices (patented). Makes alignment easier, reducing installation time and cost. Identifies which beams are broken. Identifies exact channel (fixed blanking) select beams. Simplifies troubleshooting and re-adjustment, reducing downtime.
14 and 30 mm minimum object sensitivity (MOS) 14 mm MOS protection heights: 280 - 1360 mm (11.0 - 53.5 in.) 14 mm MOS sensing range: 7.0 m (22.9 ft.) 30 mm MOS protection heights: 320 - 2120 mm (12.6 - 83.5 in.) 30 mm MOS sensing range: 8 m or 20 m (26.2 or 65.6 ft.) 38 x 50 mm housing size (1.5 x 1.97 in.) 24 Vdc supply voltage Broken beam Indicators for EVERY beam on ALL devices Female connector cables sold separately (5 m, 10 m, 15 m, and 30 m) Configurable by hand held programming and diagnostic module (PDM) Cascadable devices available in the XUSLD versions - up to 4 segments
1 to 6 beams Sensing distance up to 70 m (230 ft.) depending upon configuration Height: 750 mm (29 in.) to 1800 mm (68 in.) Minimum object sensitivities: 300, 400, 500, or 600 mm (11.8, 15.75, 19.69, or 23.62 in.) and single beam Visible, red broken beam Indicators Short circuit protected IP67 Display for diagnosis and working mode No need of shielded wire up to 120 m (394 ft.) Restart and start interlock External device monitoring /machine primary control element monitoring (EDM/MPCE) Machine test signal (MTS) 3 types of coding (A, B, C) by internal switches
25-6
XCSMP
XCS safety interlock switches verify that the doors, gates, or guards are closed before a process which could be harmful to personnel can start up. The hazards to personnel can be mechanical, electrical, hydraulic, pneumatic, chemical, or thermal. The various sizes and shapes of safety interlock switches are designed for a wide variety of applications. These mechanical devices have two components: a switch and an actuating key. When the gate or guard is closed, the actuating key attached to the gate or guard is inserted into the switch, closing the safety contacts, allowing the machine to be started. When the gate or guard is opened, the actuating key is removed from the switch, and the safety interlock switch contacts open. XCS safety interlock switches are designed to meet demanding requirements in the US and Europe, as well as the rest of the world. The flexibility of the XCS line allows one XCS device to perform the same functions as several competitors devices. This means that fewer XCS devices may be required to cover your needs. Specifically designed for the protection of machine operators, maintenance and other personnel, the XCS switches can be used in a wide range of applications where a gate, door or guard is a part of the safety system. Features and Benefits Simple, rapid installation saves time and labor Device flexibility reduces stock requirements Wide variety of body styles, contact arrangement, and operators meet a variety of application requirements Bodies available in metal or plastic Switches are interchangeable between new and older devices, as well as with competitors devices A variety of actuating keys are suitable for all applications Pre-wired devices and many connector options available to make wiring and installation easier The Following Types of Safety Interlocks are Available:
XCSDM non-contact safety interlock switches are designed for the same functions as mechanical safety interlock switches. The difference is that the non-contact safety interlock switches are magnetically coded devices and require no contact between the switch and coded magnet. This is a benefit where door or guard misalignment is an issue, or where the machine designer does not want to use a mechanical device. Benefits of Non-contact Devices:
Food, beverage and pharmaceutical applications require that no contaminants be trapped in or around devices. Non-contact devices have no inherent operating force and are well-suited for applications such as lightweight or plexiglass doors, where cracking or breakage is prevalent with standard mechanical safety interlock switches. Wash down applications where a standard mechanical safety interlock switch would be more difficult to clean, especially in the actuating key receptacle. Where small size is critical or a slim profile is desired Features and Benefits of XCSDMC, XCSDMP, and XCSDMR
Tolerates gate or guard alignment problems Wider temperature range for a plastic bodied device than any competitors products Multiple coded-magnet approach directions allow for maximum flexibility of mounting options Suitable for Category 4 safety circuits Available with or without LEDs Connector and cabled versions available Features and Benefits of XCSDM3 and XCSDM4
Non-locking Locking with push button or key release Locking by electrical solenoid Rotary shaft operation, for use on hinges of doors Rotary lever for hinged guards Pre-wired compact body
Meets SIL 2 and 3 per IEC 61508, Category 3 and 4 per EN 954-1 and ISO 13849-1 without the need for a safety relay or safety controller Connector and cabled versions available Multicolor LEDs for diagnostics and status Multiple coded-magnet approach directions allow for maximum flexibility of mounting options
25-7
25
25
MACHINE SAFETY PRODUCTS
Meet US and European safety standards requiring that switches used in safety applications have positive opening contacts Tamper resistant covers over mounting screw and head adjustment to reduce potential for tampering Red color allows easy visibility and identification of safety related limit switches Two body styles available: Compact, pre-wired with cable Compact, with conduit entry
Cable lengths: XY2CE 165 ft. and XY2CH 50 ft. Emergency stop versions (available in XY2CE and XY2CH) The N.C. contact opens the control circuit and mechanically latches, and will remain latched in the open position until an operator manually resets it Emergency stop versions have positive/direct opening contacts as standard Device will not reset if out of adjustment Normal stop versions (available in XY2CE and XY2CH) Normal stop versions are used where a momentary, non-emergency signal is required Normal stop versions do not latch contacts open or include positive opening contacts Normal stop versions are provided with snap action contacts for momentary stop
Positive opening contacts standard in all devices Snap acting contacts Slow make/slow break contacts Several head types available Metal and Plastic body styles available Several conduit types available Tamper resistant cover
XY2CE
165 ft. maximum cable length Adjustable tripping force Available with 2 N.O. and 2 N.C. contacts XY2CH 50 ft. maximum cable length Two viewing windows to aid in adjusting the switch Manual tripping force adjustment Adjustment indicator Traction force indicator
Positive opening contacts standard in all devices Snap acting contacts Slow make/slow break contacts Several head types available Plastic body Pre-wired in various cable lengths Tamper resistant cover
25-8
Table of Contents
Section 26
AC Drives and Soft Starts
AC Drives and Soft Starts
For Variable Torque Applications For Constant Torque Applications For Reduced Voltage Control 26-2 26-3 26-3
AC Drives
Altivar 21
Altivar 31 (p. 26-5) Altivar 61/ Altivar 71 (p. 26-7)
26-4 26-4
Altivar Altivar
31 61/Altivar 71
26-6
Enclosed Drives
EFlex AC Drives SFlex AC Drives 26-12 26-14
AC DRIVES
AC Drives
E-Flex AC Drives (p. 26-14)
26-1
26
26-18
AC Drive Products for Variable Torque Applications Such as Centrifugal Pumps and Fan Applications
Altivar 21
Just the right features for unmatched value in energy saving applications with 230 Vac: 140 hp and 480 Vac: 1100 hp. Major building automation communication option cards available. See Pricing Guide 8800PL9701 for more pricing information.
Altivar 21
EFlexTM
Enclosed Altivar 61 drive package with 208/230 Vac: 150 hp and 480 Vac: 1100 hp. Ideal for education campuses, commercial, retail, and condo buildings. See following pages and brochure 8800BR0501 for more information.
EFlex
26
AC DRIVES Altivar 61 SFlex
Altivar 61
Easy to use while offering high functionality and flexibility in 230 Vac:1125 hp and 480 Vac: 1900 hp and 575 Vac range. Lonworks, BACnet, Metasys N2, and Apogee P1 communication option cards available. See following pages and brochure 8800BR0601 for more information.
MFlexTM
Enclosed Altivar 71 (or Altivar 61 VT) drive package with 208/230 Vac, 140 hp (50 hp VT) and 480 Vac, 1450 hp (500 VT). Widest selection of options, I/O, communication, and custom requirements. See Pricing Guide 8800PL9701 for more pricing information.
SFlexTM New!
Enclosed drive with 208/230 Vac 1 - 40 hp and 460 Vac 1 - 100 hp. Select sizes stocked for immediate availability. See Pricing Guide 8800PL9701 for more pricing information.
MFlex
PowerGardTM Series C
This enclosed package combines the Altivar 61 (or Altivar 71) and 18 pulse technology to provide harmonic mitigation. See Pricing Guide 8800PL9701 for more pricing information.
PowerGuard
For additional pricing information reference the AC Drives and Soft start Price Guide: 8800PL9701.
26-2
AC Drive Products for Constant Torque Applications such as Conveyors, Mixers, Extruders, and Material Handling Altivar 11
Compact nano drive with 115 Vac230 Vac single-phase and 230 Vac 3-phase input. hp range of 3 hp with sensorless vector control. See Pricing Guide 8800PL9701 for more pricing information.
AC Soft Start Products for Reduced Voltage Control for Use in Variable Torque or Constant Torque Applications. Altistart 01
Compact nano and mini soft start with 115 Vac230 Vac single-phase and 208690 Vac 3-phase input. hp range of 60 hp. See following information and brochure 8637BR0401for more information.
Altistart 01
Altivar 11
Altivar 31
High feature mini drive with 230 Vac 1 phase, 230, 480 and 575 Vac 3-phase input. hp range of 20 hp with built in Modbus / CANopen port. See the following pages and brochure 8800BR0401 for more information.
Altistart 48
Full feature soft start that offers unique torque control on starting and stopping. 208690 Vac 3-phase input with a hp range of 21200 hp. See following pages and brochure 8800SM0101S for more information.
Altistart 48 Altivar 31
Altivar 71
High performance drive with 230 Vac: 1100 hp and 480 Vac: 1700 hp and 575 Vac range. Wide selection of I/O and communication options. See following pages and brochure 8800BR0505 for more information.
Enclosed Altistart 48
Enclosed version of the Altistart 48 offered in 208575 Vac 3-phase input with a hp range of 3600 hp. See brochure 8800BR0402 for more information.
MFlexTM
Enclosed Altivar 71 (or Altivar 61 VT) drive package with 208/230 Vac, 140 hp (50 hp VT) and 480 Vac, 1450 hp (500 VT). Widest selection of options, I/O, communication, and custom requirements. See Pricing Guide 8800PL9701 for more pricing information.
MFlex
For additional pricing information reference the AC Drives and Soft start Price Guide: 8800PL9701.
26-3
26
AC DRIVES
AC Drives
Altivar 21/Altivar 31
Class 8800 / Refer to Brochure 8800BR0401
www.schneider-electric.us
Table 26.2:
1 0.75 4.6 ATV21H075M3X 309. 2 1.5 7.5 ATV21HU15M3X 400. 3 2.2 10.6 ATV21HU22M3X 454. 3 13.7 ATV21HU30M3X 555. 5 4 16.7 ATV21HU40M3X 618. 7.5 5.5 24.2 ATV21HU55M3X 799. 208/240 Vac Three Phase 10 7.5 32 ATV21HU75M3X 963. 15 11 46.2 ATV21HD11M3X 1225. 20 15 61 ATV21HD15M3X 1532. 25 18.5 74.8 ATV21HD18M3X 1795. 30 22 88 ATV21HD22M3X 2188. 40 30 117 ATV21HD30M3X 2806. 1 0.75 2.2 ATV21H075N4 400. 2.4 ATV21W075N4 500. 2 1.5 3.7 ATV21HU15N4 472. 4 ATV21WU15N4 590. 3 2.2 5.1 ATV21HU22N4 545. 5.6 ATV21WU22N4 681. 3 7.2 ATV21HU30N4 618. 7.9 ATV21WU30N4 772. 5 4 8.2 ATV21HU40N4 654. 10 ATV21WU40N4 817. 7.5 5.5 12 ATV21HU55N4 798. 13.2 ATV21WU55N4 998. 10 7.5 16 ATV21HU75N4 946. 17.6 ATV21WU75N4 1183. 15 11 22.5 ATV21HD11N4 1145. 24.8 ATV21WD11N4 1489. 400/480 Vac Three Phase 20 15 30.5 ATV21HD15N4 1425. 33.6 ATV21WD15N4 1853. 25 18.5 37 ATV21HD18N4 1705. 40.7 ATV21WD18N4 2131. 30 22 43.5 ATV21HD22N4 1856. 47.9 ATV21WD22N4 2412. 40 30 58.5 ATV21HD30N4 2284. 64.4 ATV21WD30N4 2855. 50 37 79 ATV21HD37N4 2686. 86.9 ATV21WD37N4 3358. 60 45 94 ATV21HD45N4 3372. 103.4 ATV21WD45N4 4215. 75 55 116 ATV21HD55N4 3883. 127.6 ATV21WD55N4 4853. 100 75 160 ATV21HD75N4 4433. 176 ATV21WD75N4 5541. a These horsepower, wattage and continuous ampere ratings apply to default switching frequency and maximum 40 C ambient. Refer to the installation manual for derating curves as a function of switching frequency, ambient temperature, and mounting conditions. b Open type Altivar 21 Drives can be installed as UL Type 1 with an optional conduit box when following instructions in the Installation Manual c For ATV21 with Class B EMC filter, add the letter "C" to the end of the standard catalog number and multiply $ Price by 1.3.
.
26
AC DRIVES ATV31H Open Type Drive ATV31C IP54 / UL Type 12
Table 26.3:
Input Line Voltage
0.18 0.25 1.5 ATV31H018M2 268. 308. 1.5 ATV31C018M2 362. 0.37 0.5 3.3 ATV31H037M2 287. 330. 3.3 ATV31C037M2 387. 0.55 0.75 3.7 ATV31H055M2 306. 352. 3.7 ATV31C055M2 413. 208/230 Vac 0.75 1 4.6 ATV31H075M2 335. 385. 4.6 ATV31C075M2 452. Single Phase 1.1 1.5 6.9 ATV31HU11M2 363. 418. 6.9 ATV31CU11M2 490. 1.5 2 8 ATV31HU15M2 402. 462. 8 ATV31CU15M2 543. 2.2 3 11 ATV31HU22M2 468. 539. 11 ATV31CU22M2 632. 0.18 0.25 1.5 ATV31H018M3X 258. 297. 0.37 0.5 3.3 ATV31H037M3X 287. 330. 0.55 0.75 3.7 ATV31H055M3X 306. 352. 0.75 1 4.8 ATV31H075M3X 325. 374. 1.1 1.5 6.9 ATV31HU11M3X 363. 418. 1.5 2 8 ATV31HU15M3X 421. 484. 208/230 Vac 2.2 3 11 ATV31HU22M3X 478. 550. Three Phase 3 4 13.7 ATV31HU30M3X 554. 638. 650. 748. 5 17.5 ATV31HU40M3X 5.5 7.5 27.5 ATV31HU55M3X 841. 967. 7.5 10 33 ATV31HU75M3X 1013. 1165. 11 15 54 ATV31HD11M3X 1338. 1539. 15 20 66 ATV31HD15M3X 1721. 1979. a These horsepower, wattage, and continuous ampere ratings apply to 4 kHz switching frequency and maximum 50 C ambient. Refer to the installation manual for derating curves as a function of switching frequency, ambient temperature, and mounting conditions. b Open type Altivar 31 Drives can be installed as UL Type 1 with optional conduit box when following instructions in the installation manual. c Add the letter A to the end of the standard open type catalog number for a drive controller with a reference potentiometer and RUN/STOP buttons. This does not apply to the IP54 / UL Type 12 products.
26-4
CP4B
Discount Schedule
AC Drives
www.schneider-electric.us
Altivar 31
Class 8800 / Refer to Brochure 8800BR0401 Altivar 31 Selection and Pricing (continued)
Open Drives b Aa Catalog Number Standard $ Price Local Control $ Price c Aa IP54 / UL Type 12 Enclosed Catalog Number Class A EMC $ Price
Table 26.2:
Input Line Voltage
Table 26.3:
User Interface Kits a Remote Keypad Display Mounting Kit Includes remote, keypad, remote mounting hardware, and 3 meter cable. Communication Card Kits LONWORKS The card is equipped with a removable 3-way screw terminal block. ATV21 all ranges METASYS N2 The card is equipped with a removable 4-way screw terminal block. ATV21 all ranges APOGEE FLN P1 The card is equipped with a removable 4-way screw terminal block. ATV21 all ranges BACnet The card is equipped with a remote 4-way screw terminal block. ATV 21 all ranges a Reference Catalog #8800PL9701R8/08 for communication cables, and additional options and accessories.
Table 26.4:
Multiple knockout sizes Installation of conduit entrance kit and retention of vent cover on top of drive controller provides the ATV21 and ATV 31 with UL Type 1 rating
ATV21HU30M3X, ATV21HU40M3X, ATV21HU30N4, ATV21HU40N4, ATV21HU55N4 ATV21HU55M3X, ATV21HU75M3X, ATV21HU75N4, ATV21HD11N4 ATV21HD11M3X, ATV21HD15M3X, ATV21HD18M3X, ATV21HD15N4, ATV21HD18N4 ATV21HD22M3X, ATV21HD22N4, ATV21HD30N4 ATV21HD37N4, ATV21HD45N4 ATV21HD30M3X, ATV21HD55N4, ATV21HD75N4
VW3A31815
45.
CP4B
Discount Schedule
26-5
26
AC DRIVES
0.37 0.5 1.5 ATV31H037N4 363. 418. 1.5 ATV31C037N4 490. 0.55 0.75 1.9 ATV31H055N4 392. 451. 1.9 ATV31C055N4 529. 0.75 1 2.3 ATV31H075N4 421. 484. 2.3 ATV31C075N4 568. 1.1 1.5 3 ATV31HU11N4 449. 517. 3 ATV31CU11N4 606. 1.5 2 4.1 ATV31HU15N4 497. 572. 4.1 ATV31CU15N4 671. 2.2 3 5.5 ATV31HU22N4 574. 660. 5.5 ATV31CU22N4 774. 400/480 Vac Three Phase 3 4 7.1 ATV31HU30N4 650. 748. 7.1 ATV31CU30N4 878. 5 9.5 ATV31HU40N4 688. 792. 9.5 ATV31CU40N4 929. 5.5 7.5 14.3 ATV31HU55N4 860. 989. 14.3 ATV31CU55N4 1162. 7.5 10 17 ATV31HU75N4 1052. 1209. 17 ATV31CU75N4 1420. 11 15 27.7 ATV31HD11N4 1386. 1594. 27.7 ATV31CD11N4 1733. 15 20 33 ATV31HD15N4 1721. 1979. 33 ATV31CD15N4 2151. 484. 0.75 1 1.7 ATV31H075S6X 1.5 2 2.7 ATV31HU15S6X 572. 2.2 3 3.9 ATV31HU22S6X 660. 575/600 Vac 3.7/4.0 5 6.1 ATV31HU40S6X 792. Three Phase 5.5 7.5 9 ATV31HU55S6X 989. d 7.5 10 11 ATV31HU75S6X 1209. 11 15 17 ATV31HD11S6X 1594. 15 20 22 ATV31HD15S6X 1979. a These horsepower, wattage and continuous ampere ratings apply to 4 kHz switching frequency and maximum 50 C ambient. Refer to the installation manual for derating curves as a function of switching frequency, ambient temperature, and mounting conditions. b Open type Altivar 31 drives can be installed as UL Type 1 with optional conduit box when following instructions in the installation manual c Add the letter A to the end of the standard open type catalog number for a drive controller with a reference potentiometer and RUN/STOP buttons. This does not apply to the IP54 / UL Type 12 products. d A minimum 3% line reactor is required on all 575 V drive installations.
AC Drives
Altivar 61/Altivar 71
Class 8800 / Refer to Brochure 8800BR0601
www.schneider-electric.us
Table 26.5:
$ Price
$ Price
$ Price
Catalog Number hp kW A Catalog Number Catalog Number to have ATV61 and Type 1 with LED Keypad with LCD Keypad conduit \entry kit shipped as (Nonstocked) (Stocked) one line item. Field installation required (Packaged as kit at warehouse). 0.5 0.37 3 ATV61H075M3 aeg 639. ATV61H075M3T1 e 684. ATV61H075M3Z 544. 1 0.75 4.8 ATV61HU15M3 aeg 663. ATV61HU15M3T1e 708. ATV61HU15M3Z 568. 2 1.5 8 ATV61HU22M3 aeg 764. ATV61HU22M3T1 e 809. ATV61HU22M3Z 669. 208/240 Vac Single 3 2.2 11 ATV61HU30M3 aeg 925. ATV61HU30M3T1 e 970. ATV61HU30M3Z 830. Phase 4 3 13.7 ATV61HU40M3 abeg 1035. ATV61HU40M3T1 be 1080. ATV61HU40M3Z b 940. 5 4 17.5 ATV61HU55M3 abeg 1292. ATV61HU55M3T1 be 1337. ATV61HU55M3Z b 1197. 7.5 5.5 27.5 ATV61HU75M3 abeg 1586. ATV61HU75M3T1 be 1631. ATV61HU75M3Z b 1491. ATV61H075M3T1 e 684. ATV61H075M3Z 544. 1 0.75 4.8 ATV61H075M3 aeg 639. 2 1.5 8 ATV61HU15M3 aeg 663. ATV61HU15M3T1e 708. ATV61HU15M3Z 568. 3 2.2 11 ATV61HU22M3 aeg 764. ATV61HU22M3T1e 809. ATV61HU22M3Z 669. 4 3 13.7 ATV61HU30M3 aeg 925. ATV61HU30M3T1e 970. ATV61HU30M3Z 830. 5 4 17.5 ATV61HU40M3 aeg 1035. ATV61HU40M3T1 e 1080. ATV61HU40M3Z 940. 7.5 5.5 27.5 ATV61HU55M3 aeg 1292. ATV61HU55M3T1 e 1337. ATV61HU55M3Z 1197. 10 7.5 33 ATV61HU75M3 aeg 1586. ATV61HU75M3T1 e 1631. ATV61HU75M3Z 1491. 15 11 54 ATV61HD11M3Xcegh 2011. ATV61HD11M3XT1 ce 2056. ATV61HD11M3XZ c 1916. 208/240 Vac 20 15 66 ATV61HD15M3Xcegh 2525. ATV61HD15M3XT1 ce 2570. ATV61HD15M3XZ c 2430. Three Phase 25 18 75 ATV61HD18M3X cegh 2943. ATV61HD18M3XT1ce 3008. 30 22 88 ATV61HD22M3X cegh 3586. ATV61HD22M3XT1 ce 3651. 40 30 120 ATV61HD30M3X cegh 4599. ATV61HD30M3XT1ce 4684. 50 37 144 ATV61HD37M3X cegh 5342. ATV61HD37M3XT1 ce 5427. 60 45 176 ATV61HD45M3X cegh 6326. ATV61HD45M3XT1 ce 6411. 75 55 221 ATV61HD55M3X cdegh 7806. ATV61HD55M3XT1 ce 8266. 100 75 285 ATV61HD75M3X cdegh 9379. ATV61HD75M3XT1 ce 9839. 125 90 359 ATV61HD90M3X cdegh 11954. ATV61HD90M3XT1 ce 12507. 1 0.75 2.3 ATV61H075N4 aeg 754. ATV61H075N4T1 e 799. ATV61H075N4Z 659. 2 1.5 4.1 ATV61HU15N4 aeg 857. ATV61HU15N4T1 e 902. ATV61HU15N4Z 762. 3 2.2 5.8 ATV61HU22N4 aeg 999. ATV61HU22N4T1 e 1044. ATV61HU22N4Z 904. 4 3 7.8 ATV61HU30N4 aeg 1125. ATV61HU30N4T1 e 1170. ATV61HU30N4Z 1030. 5 4 10.5 ATV61HU40N4 aeg 1158. ATV61HU40N4T1 e 1203. ATV61HU40N4Z 1063. 7.5 5.5 14.3 ATV61HU55N4 aeg 1299. ATV61HU55N4T1 e 1344. ATV61HU55N4Z 1204. 10 7.5 17.6 ATV61HU75N4 aeg 1578. ATV61HU75N4T1 e 1623. ATV61HU75N4Z 1483. 15 11 27.7 ATV61HD11N4 aeg 1868. ATV61HD11N4T1 e 1913. ATV61HD11N4Z 1773. 20 15 33 ATV61HD15N4 aeg 2322. ATV61HD15N4T1e 2367. ATV61HD15N4Z 2227. 25 18 41 ATV61HD18N4 aeg 2795. ATV61HD18N4T1 e 2840. ATV61HD18N4Z 2700. 30 22 48 ATV61HD22N4 aeg 3042. ATV61HD22N4T1 e 3107. ATV61HD22N4Z 2947. 40 30 66 ATV61HD30N4 aeg 3744. ATV61HD30N4T1 e 3809. ATV61HD30N4Z 3649. 400/480 Vac 50 37 79 ATV61HD37N4 aeg 4403. ATV61HD37N4T1 e 4468. ATV61HD37N4Z 4308. Three 60 45 94 ATV61HD45N4 aeg 5528. ATV61HD45N4T1 e 5663. ATV61HD45N4Z 5433. Phase 75 55 116 ATV61HD55N4 aeg 6365. ATV61HD55N4T1 e 6500. ATV61HD55N4Z 6270. 100 75 160 ATV61HD75N4 aeg 7267. ATV61HD75N4T1 e 7402. ATV61HD75N4Z 7172. 125 90 179 ATV61HD90N4 deg 7988. ATV61HD90N4T1 e 8448. 150 110 215 ATV61HC11N4 deg 9022. ATV61HC11N4T1 e 9575. 200 130 259 ATV61HC13N4 deg 10366. ATV61HC13N4T1 e 10939. 250 160 314 ATV61HC16N4deg 11711. ATV61HC16N4T1 e 12284. 350 220 427 ATV61HC22N4 deg 13993. ATV61HC22N4T1 e 14581. 400 250 481 ATV61HC25N4 defg 16475. 500 315 616 ATV61HC31N4 defg 23734. 600 400 759 ATV61HC40N4 dfg 31783. 700 500 941 ATV61HC50N4 dfg 44235. 900 630 1188 ATV61HC63N4 dfg 63935. a Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. Add S337 to the end of the catalog number and multiply the listed price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55 kW/75 hp @ 230 Vac and higher and 90 kW/125 hp @ 460 Vac and higher. b These products require a user supplied 3% line reactor when used with single-phase input. c Product does not contain an EMC filter. d Product ships with a DC choke that must be field mounted. A 5% line reactor may be purchased and installed in place of the DC choke. Add D to the end of the catalog number to receive just the AC drive and multiply the listed price by .96 to obtain new price. e These products can be ordered with LonWorks or BACnet communication option card shipped as one line item. Field installation required. Add LW to the end of the part number to receive a LonWorks option card. Add $550 to the list price. Add BN to the end of the part number to receive a BACnet option card. Add $225 to the list price. f These products do not contain a dynamic braking transistor. A separate transistor must be added for applications requiring dynamic braking. g When ordering replacements for Square D E-Flex, MCC, and M-Flex containing an Altivar 61 drive, identify the replacement catalog number by referring to the applicable instruction manual, the side nameplate on the power converter, or using the graphic keypad (menu 1.11 identification). h Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. Add 337 to the end of the catalog number and multiply the listed price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55 kW/75 hp @ 230 Vac and higher and 90 kW/125 hp @ 460 Vac and higher.
26
AC DRIVES
26-6
CP4C
Discount Schedule
AC Drives
www.schneider-electric.us
Altivar 61/Altivar 71
Class 8800 / Refer to Brochure 8800BR0601 (ATV 61) or 8800BR0505 (ATV 71) Altivar 61 Selection and Pricing (continued)
Variable Torque Three-Phase Motor Power Continuous Output Current
Table 26.5:
Input Line Voltage hp kW A Catalog Number with LCD Keypad (Stocked) ATV61HU30Y i ATV61HU40Y i ATV61HU55Y i ATV61HU75Y i ATV61HD11Y i ATV61HD15Y i ATV61HD18Y i ATV61HD22Y i ATV61HD30Y i ATV61HD37Y i ATV61HD45Y i ATV61HD55Y i ATV61HD75Y i ATV61HD90Y i ATV61HC11Y i j ATV61HC13Y i j ATV61HC16Y i j ATV61HC20Y i j ATV61HC25Y i j ATV61HC31Y i j ATV61HC40Y i j ATV61HC50Y i j j ATV61HC63Y i j ATV61HC80Y i j
$ Price
3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 350 450 550 700 800
3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 400 500 630 800
3.9 5.8 6.1 9 11 17 22 27 32 41 52 62 77 99 125 150 180 220 290 355 420 543 675 840
1889. 1990. 2099. 2380. 2799. 3380. 3979. 4790. 5780. 6999. 8579. 10379. 12199. 14399. 16899. 19179. 20795. 24290. 28950. 35950. 46750. 59590. 78490. 103390.
i j
Constant Torque
$ Price
$ Price
$ Price
Catalog Number ATV71 drive and Type 1 conduit entry kit 0.5 1 2 3 4 5 7.5 0.5 1 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 0.37 0.75 1.5 2.2 3 4 5.5 0.37 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18 22 30 7 45 55 75 3 4.8 8 11 13.7 17.5 27.5 3 4.8 8 11 13.7 17.5 27.5 33 54 66 75 88 120 144 176 221 285 ATV71H075M3 a ATV71HU15M3 a ATV71HU22M3 a ATV71HU30M3 a ATV71HU40M3 a c ATV71HU55M3 a c ATV71HU75M3 a c ATV71H037M3 a f ATV71H075M3 a f ATV71HU15M3 a f ATV71HU22M3 a f ATV71HU30M3 a f ATV71HU40M3 a f ATV71HU55M3 a f ATV71HU75M3 a f ATV71HD11M3X c e f ATV71HD15M3X c e f ATV71HD18M3X c e f ATV71HD22M3X c e f ATV71HD30M3X c e f ATV71HD37M3X c e f ATV71HD45M3X c e f ATV71HD55M3X c d e ATV71HD75M3X c d e 652. 684. 796. 984. 1150. 1458. 1790. 616. 652. 684. 796. 984. 1150. 1458. 1790. 2270. 2850. 3422. 4170. 5348. 6212. 7356. 8870. 10658. ATV71H075M3T1 ATV71HU15M3T1 ATV71HU22M3T1 ATV71HU30M3T1 ATV71HU40M3T1 c ATV71HU55M3T1 c ATV71HU75M3T1 c ATV71H037M3T1 ATV71H075M3T1 ATV71HU15M3T1 ATV71HU22M3T1 ATV71HU30M3T1 ATV71HU40M3T1 ATV71HU55M3T1 ATV71HU75M3T1 ATV71HD11M3XT1 c ATV71HD15M3XT1 c ATV71HD18M3XT1 c ATV71HD22M3XT1 c ATV71HD30M3XT1 c ATV71HD37M3XT1 c ATV71HD45M3XT1 c ATV71HD55M3XT1 c ATV71HD75M3XT1 c 697. 729. 841. 1029. 1195. 1503. 1835. 661. 697. 729. 841. 1029. 1195. 1503. 1835. 2315. 2895. 3487. 4235. 5433. 6297. 7491. 9330. 11211.
Catalog Number with LED Keypad (Nonstocked) ATV71H075M3Z ATV71HU15M3Z ATV71HU22M3Z ATV71HU30M3Z ATV71HU40M3Z c ATV71HU55M3Z c ATV71HU75M3Z c ATV71H037M3Z ATV71H075M3Z ATV71HU15M3Z ATV71HU22M3Z ATV71HU30M3Z ATV71HU40M3Z ATV71HU55M3Z ATV71HU75M3Z ATV71HD11M3XZ ATV71HD15M3XZ 557. 589. 701. 889. 1055. 1363. 1695. 521. 557. 589. 701. 889. 1055. 1363. 1695. 2175. 2755.
LCD Keypad
208/240 Vac Single Phase
LED Keypad
CP4C
Discount Schedule
26-7
26
Table 26.6:
AC DRIVES
AC Drives
Altivar 61/Altivar 71
Class 8800 / Refer to Brochure 8800BR0505
www.schneider-electric.us
Table 26.6:
$ Price
$ Price
$ Price
ATV71HC28N4
Catalog Number hp kW A to have ATV71 drive and Type 1 conduit entry kit Catalog Number Catalog Number shipped as one line item. with LED Keypad with LCD Keypad Field installation required (Nonstocked) (Stocked) (Packaged as kit at warehouse). 1 0.75 2.3 ATV71H075N4 a e 794. ATV71H075N4T1 839. ATV71H075N4Z 699. 2 1.5 4.1 ATV71HU15N4 a e 912. ATV71HU15N4T1 957. ATV71HU15N4Z 817. 3 2.2 5.8 ATV71HU22N4 a e 1110. ATV71HU22N4T1 1155. ATV71HU22N4Z 1015. 4 3 7.8 ATV71HU30N4 a e 1250. ATV71HU30N4T1 1295. ATV71HU30N4Z 1155. 5 4 10.5 ATV71HU40N4 a e 1316. ATV71HU40N4T1 1361. ATV71HU40N4Z 1221. 7.5 5.5 14.3 ATV71HU55N4 a e 1584. ATV71HU55N4T1 1629. ATV71HU55N4Z 1489. 10 7.5 17.6 ATV71HU75N4 a e 1924. ATV71HU75N4T1 1969. ATV71HU75N4Z 1829. 15 11 27.7 ATV71HD11N4 a e 2278. ATV71HD11N4T1 2323. ATV71HD11N4Z 2183. 20 15 33 ATV71HD15N4 a e 2832. ATV71HD15N4T1 2877. ATV71HD15N4Z 2737. 25 18 41 ATV71HD18N4 a e 3408. ATV71HD18N4T1 3453. ATV71HD18N4Z 3313. 30 22 48 ATV71HD22N4 a e 3710. ATV71HD22N4T1 3775. ATV71HD22N4Z 3615. 40 30 66 ATV71HD30N4 a e 4566. ATV71HD30N4T1 4631. ATV71HD30N4Z 4471. 400/480 Vac 50 37 79 ATV71HD37N4 a e 5370. ATV71HD37N4T1 5435. ATV71HD37N4Z 5275. Three 60 45 94 ATV71HD45N4 a e 6742. ATV71HD45N4T1 6877. ATV71HD45N4Z 6647. Phase 75 55 116 ATV71HD55N4 a e 7762. ATV71HD55N4T1 7897. ATV71HD55N4Z 7667. 100 75 160 ATV71HD75N4 a e 8862. ATV71HD75N4T1 8997. ATV71HD75N4Z 8767. 125 90 179 ATV71HD90N4 d e 9742. ATV71HD90N4T1 10202. 150 110 215 ATV71HC11N4 d e 11002. ATV71HC11N4T1 11555. 200 130 259 ATV71HC13N4 d e 12642. ATV71HC13N4T1 13215. 250 160 314 ATV71HC16N4 d e 14282. ATV71HC16N4T1 14870. 300 200 387 ATV71HC20N4 d e 16462. ATV71HC20N4T1 17066. 400 250 481 ATV71HC25N4 d e 19382. ATV71HC25N4T1 19986. 450 280 550 ATV71HC28N4 d e 23002. ATV71HC28N4T1 23606. 500 310 616 ATV71HC31N4 d e 27922. 600 400 759 ATV71HC40N4 d e 37392. 700 500 941 ATV71HC50N4 d e 52041. 2 2.2 2.7 ATV71HU22Y g 1889. 3 3 3.9 ATV71HU30Y g 1990. 4 4 5.8 ATV71HU40Y g 2099. 5 5.5 6.1 ATV71HU55Y g 2380. 7.5 7.5 9 ATV71HU75Y g 2799. 10 11 11 ATV71HD11Y g 3380. 15 15 17 ATV71HD15Y g 3979. 20 18.5 22 ATV71HD18Y g 4790. 25 22 27 ATV71HD22Y g 5780. 30 30 32 ATV71HD30Y g 6999. 40 37 41 ATV71HD37Y g 8579. 575/690 Vac 50 45 52 ATV71HD45Y g 10379. Three 60 55 62 ATV71HD55Y g 12199. Phase 75 75 77 ATV71HD75Y g 14399. 100 90 99 ATV71HD90Y g 16899. 125 110 125 ATV71HC11Y g 19179. 150 132 150 ATV71HC13Y g h 23795. 175 160 180 ATV71HC16Y g h 24290. 200 200 220 ATV71HC20Y g h 28950. 250 250 290 ATV71HC25Y g h 35950. 350 315 355 ATV71HC31Y g h 46750. 450 400 420 ATV71HC40Y g h 59590. 550 500 543 ATV71HC50Y g h 78490. 700 630 675 ATV71HC63Y g h 103390. a Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. Add S337 to the end of the catalog number and multiply the listed price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55 kW/75 hp @ 230 Vac and higher and 90 kW/125 hp @ 460 Vac and higher. b These products require a user supplied 3% line reactor when used with single-phase input. c Product does not contain an EMC filter. d Product ships with a DC choke that must be field mounted. A 5% line reactor may be purchased and installed in place of the DC choke. Add D to the end of the catalog number to receive just the AC drive and multiply the listed price by .96 to obtain new price. e Also possible for use with a synchronous motor. Add387 to the end of the catalog number and multiply the list price by 1.1 to obtain the price. f Option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. Add 337 to the end of the catalog number and multiply the listed price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55 kW/75 hp @ 230 Vac and higher and 90 kW/125 hp @ 460 Vac and higher. g Conformal coating is standard. h An AC 5% line reactor is mandatory.
26
AC DRIVES
26-8
CP4C
Discount Schedule
AC Drives
www.schneider-electric.us
2 3
Altivar 61/Altivar 71
Class 8800
Table 26.7:
OptionsField Installed
Description For Use on Drives Catalog No. VW3A1101 VW3A1102 VW3A1103 VW3A1104R10 VW3A1104R30 VW3A1104R50 VW3A1104R100 VW3A1105 Altivar AC drives Altistart 48 Tesys Uline any ATV61 any ATV71 any ATV61 any ATV71 any ATV61 any ATV71 any ATV61 any ATV71 any ATV61 any ATV71 VW3A8104 VW3A8106 VW3A8114 VW3A3101 VW3A3201 VW3A3202 VW3CANA71 VW3CANKCDF180T VW3A3401 VW3A3402 VW3A3403 VW3A3404 VW3A3405 VW3A3406 VW3A3407 VW3A3408 b VW3A3409 b VW3A3411 b VW3A3302 VW3A3303 VW3A3310D VW3A3304 VW3A3307 VW3A3307S371 VW3A3309 VW3A3316 VW3A3311 VW3A3312 VW3A3313 VW3A3314 VW3A3315 VW3A3501 a $ Price 115. 55. 45. 35. 35. 35. 45. 35. 150. 75. 125. 195. 165. 195. 45. 45. 85. 85. 85. 85. 85. 85. 85. 85. 85. 85. 550. 225. 275. 550. 550. 550. 225. 275. 550. 550. 225. 225. 225. 550. 650. LCD graphic keypad: IP54 rating Remote mounting kit: includes bezel and mounting hardware Door for use with remote mount kit for IP65 rating 1 meter Cable for remote mounting LCD graphic 3 meters keypad 5 meter RJ-45 connector on each end 10 meters RJ-45 femalefemale adaptor to connect LCD keypad and cable. Not required if using VW3A1102. PowerSuite software on CD for PC Cable connection kit for PC Modbus to Bluetooth Gateway and RS-485 converter 115 Vac logic input adaptor adapts 7 logic inputs for use with user supplied 115 Vac signals Basic I/O option card4 logic inputs, 2 logic outputs, 1 Form C relay output, an input for PTC motor probes, a 24 Vdc output, a 10 Vdc output Extended I/O option cardcontains all the I/O on the Basic I/O option card plus 2 analog inputs, 2 analog outputs, 1 pulse input This adaptor connects to the RJ-45 port and provides a 9pin male SUB D connector conforming to the CANopen standard (CIA DRP 3031) 9pin female SUBD with line terminator (can be disabled). 180 cable outlet CANH, CANL, CANGND connection
Operator Interface
4
CANopen Connector
with RS-422 outputs, 5 Vdc with RS-422 outputs, 15 Vdc with open collector outputs, 12 Vdc with open collector outputs, 15 Vdc Incremental with pushpull outputs, 12 Vdc Encoder Interface with pushpull outputs, 15 Vdc Option Cards with pushpull outputs, 24 Vdc Resolver Universal with SinCos, SinCos Hiperface, SinCos EnDat or SSI output incremental with RS422 outputs and encoder emulation Modbus Plus card Modbus / Unitelway card Modbus TCP/IP Daisy Chain Interbus S card Profibus DP card Profibus DPv1 card Communication DeviceNet card Option Cards Ethernet/IP card Fipio card Lonworks card MetaSYS N2 card APOGEE FLN P1 card BACnet card Controller Programmable option card, conforms with IEC611313 programming Inside standard. Option Card
any ATV71
any ATV61
Water Solutions This option card contains a variety of preprogrammed functions and any ATV61 VW3A3503a features to manage multipump installations. any ATV71 Card a The drive cannot support the VW3A3503 water solutions card and the VW3A3501 controller inside option card simultaneously. b For use with the ATV71H...383 drive ONLY.
CP4C
Discount Schedule
26-9
26
AC DRIVES
AC Drives
Altivar 61/Altivar 71
Class 8800
www.schneider-electric.us
Table 26.7:
Fan Kit
ATV61/71HD18M3X...HD22M3X, VW3A9404 ATV61/71HD22N4 ATV61/71HD30N4...HD37N4 VW3A9405 ATV61/71HD30M3X...HD45M3X VW3A9406 ATV61/71HD45N4...HD75N4 VW3A9407 ATV61: Options and Accessories Variable Torque Applications Description Reference Mounting ATV58 Drive Replaced bya Plate Mounting Kit includes: Mechanical adaptors required for Single-phase supply voltage: 200240V 50/60 Hz Plate Kit mounting and Altivar 61/71 drive in the place ATV58HU09M2ZU ATV61H075M3 VW3A9301 of an Altivar 58 or Altivar 58F drive using same ATV58HU18M2ZU ATV61HU15M3 VW3A9301 holes. ATV58HU29M2ZU ATV61HU22M3 VW3A9303 ATV58HU41M2ZU ATV61HU30M3 VW3A9303 ATV58HU72M2ZU ATV61HU40M3 VW3A9304 ATV58HU90M2ZU ATV61HU55M3 VW3A9306 ATV58HD12M2ZU ATV61HU75M3 VW3A9307 Three-phase supply voltage 200240 V 50/60 hz ATV58HU29M2ZU ATV61HU15M3 VW3A9302 ATV58HU41M2ZU ATV61HU22M3 VW3A9303 ATV58HU54M2ZU ATV61HU30M3 VW3A9304 ATV58HU72M2ZU ATV61HU40M3 VW3A9304 ATV58HU90M2ZU ATV61HU55M3 VW3A9306 ATV58HD12M2ZU ATV61HU75M3 VW3A9307 ATV58HD16M2XZU ATV61HD11M3X VW3A9309 ATV58HD16M2XZU ATV61HD15M3X VW3A9309 ATV58HD23M2XZU ATV61HD18M3X VW3A9310 ATV58HD28M2XZU ATV61HD22M3X VW3A9312 ATV58HD33M2XZU ATV61HD30M3X VW3A9312 ATV58HD46M2XZU ATV61HD37M3X VW3A9312 Three-phase supply voltage:380480V 50/60 Hz ATV58HU18N4ZU ATV61H075N4 VW3A9302 ATV58HU29N4ZU ATV61HU15N4 VW3A9302 ATV58HU41N4ZU ATV61HU22N4 VW3A9302 ATV58HU54N4XZU ATV61HU40N4 VW3A9304 ATV58HU72N4XZU ATV61HU55N4 VW3A9305 ATV58HU90N4XZU ATV61HU75N4 VW3A9305 ATV58HD12N4XZU ATV61HD11N4 VW3A9307 ATV58HD16N4XZU ATV61HD15N4 not available ATV58HD23N4XZU ATV61HD18N4 VW3A9308 ATV58HD28N4XZU ATV61HD22N4 VW3A9310 ATV58HD33N4XZU ATV61HD30N4 VW3A9310 ATV58HD46N4XZU ATV61HD37N4 VW3A9310 ATV58HD54N4XZU ATV61HD45N4 VW3A9312 ATV58HD64N4XZU ATV61HD55N4 VW3A9312 ATV58HD79N4XZU ATV61HD75N4 VW3A9312 ATV71: Options and Accessories Constant Torque Applications Reference Mounting ATV58 Drive Replaced by Plate Single-phase supply voltage: 200240V 50/60 Hz ATV58HU09M2ZU ATV71H075M3 VW3A9301 ATV58HU18M2ZU ATV71HU15M3 VW3A9301 ATV58HU29M2ZU ATV71HU22M3 VW3A9303 ATV58HU41M2ZU ATV71HU30M3 VW3A9303 ATV58HU72M2ZU ATV71HU40M3 VW3A9304 ATV58HU90M2ZU ATV71HU55M3 VW3A9306 ATV58HD12M2ZU ATV71HU75M3 VW3A9307 Three-phase supply voltage: 200240V 50/60 Hz ATV58HU29M2ZU ATV71HU15M3 VW3A9302 ATV58HU41M2ZU ATV71HU22M3 VW3A9303 ATV58HU54M2ZU ATV71HU30M3 VW3A9304 ATV58HU72M2ZU ATV71HU40M3 VW3A9304 ATV58HU90M2ZU ATV71HU55M3 VW3A9306 ATV58HD12M2ZU ATV71HU75M3 VW3A9307 ATV58HD16M2XZU ATV71HD11M3X VW3A9309 ATV58HD23M2XZU ATV71HD15M3X VW3A9309 ATV58HD28M2XZU ATV71HD18M3X VW3A9312 ATV58HD33M2XZU ATV71HD22M3X VW3A9312 ATV58HD46M2XZU ATV71HD30M3X VW3A9312 Three-phase supply voltage 380480 V 50/60 HZ ATV58HU18N4ZU ATV71H075N4 VW3A9302 ATV58HU29N4ZU ATV71HU15N4 VW3A9302 ATV58HU41N4ZU ATV71HU22N4 VW3A9302 ATV58HU54N4bZU ATV71HU30N4 VW3A9304 ATV58HU72N4bZU ATV71HU40N4 VW3A9304 ATV58HU90N4bZU ATV71HU55N4 VW3A9305 ATV58HD12N4bZU ATV71HU75N4 VW3A9306 ATV58HD16N4bZU ATV71HD11N4 VW3A9307 ATV58HD23N4bZU ATV71HD15N4 VW3A9308 ATV58HD28N4bZU ATV71HD18N4 VW3A9309 ATV58HD33N4bZU ATV71HD22N4 VW3A9310 ATV58HD46N4bZU ATV71HD30N4 VW3A9310 ATV58HD54N4bZU ATV71HD37N4 VW3A9312 ATV58HD64N4bZU ATV71HD45N4 VW3A9312 ATV58HD79N4bZU ATV71HD55N4 VW3A9312 a Verify motor/drive ratings and application for proper replacement selections. b Catalog number may or may not contain an X in this position.
26
AC DRIVES
26-10
CP4C
Discount Schedule
AC Drives
www.schneider-electric.us
Altivar 61/Altivar 71
Class 8800
Table 26.7:
Flange Kit
Kit includes: ATV61/71H037M3...HU15M3 a metal frame, seals, mounting hardware, ATV61/71H075N4...HU22N4 and bracket to mount fan kit so fan can be accessed from the front of the drive template ATV61/71HU22M3...HU40M3 ATV61/71HU30N4...HU40N4 Kit used to mount the heatsink of the drive ATV61/71HU55M3 outside of an enclosure. ATV61/71HU55N4, HU75N4 ATV61/71HU75M3 ATV61/71HD11N4 ATV61/71HD11M3X..HD15M3X ATV61/71HD15N4, HD18N4 ATV61/71HD18M3X..HD22M3X ATV61/71HD22N4, ATV61/71HU30Y...HD30Y ATV61/71HD30N4, HD37N4 ATV61/71HD30M3X..HD45M3X ATV61/71HD45N4...HD75N4, ATV61/71HD37Y...HD90Y ATV61HD55M3X...HD75M3X ATV61HD90N4...HC11N4 ATV71HD55M3X, ATV71HD90N4 ATV61HD90M3X, ATV61HC13N4 ATV71HD75M3X, ATV71HC11N4 ATV61HC16N4, ATV61HC20Y, ATV61/71HC11Y...HC16Y, ATV71HC13N4 ATV61HC22N4, ATV71HC16N4 ATV61HC25N4HC31N4 ATV61HC40Y ATV61/71HC25Y, HC31Y ATV71HC20N4...HC28N4 ATV71HC20Y ATV61HC25N4HC31N4 with VW3A7101 braking transistor ATV61HC40Y ATV61/71HC25Y, HC31Y ATV71HC20N4...HC28N4 with VW3A7101 braking transistor ATV71HC20Y Type 1 Kit includes: ATV61/71H037M3...HU15M3 Conduit Kit a metal box, with conduit knockouts Kit ATV61/71H075N4...HU22N4 provides conduit landing when wall mounting ATV61/71HU22M3...HU40M3 the drive ATV61/71HU30N4...HU40N4 ATV61/71HU55M3 ATV61/71HU55N4, HU75N4 ATV61/71HU75M3 ATV61/71HD11N4 ATV61/71HD11M3X..HD15M3X ATV61/71HD15N4, HD18N4 ATV61/71HD18M3X..HD22M3X ATV61/71HD22N4 ATV61/71HU30Y...HD30Y ATV61/71HD30N4, HD37N4 ATV61/71HD30M3X..HD45M3X ATV61/71HD45N4..HD75N4 ATV61/71HD37Y...HD90Y ATV61HD55M3X...HD75M3X ATV61HD90N4...HC11N4 ATV71HD55M3X, ATV71HD90N4, ATV61HC11N4 ATV61HD90M3X, ATV61HC13N4 ATV71HD75M3X, ATV71HC11N4 ATV61HC16N4, ATV71HC13N4 ATV61/71HC11Y...HC16Y ATV61HC20Y ATV61HC22N4, ATV71HC16N4 ATV61HC25N4...ATV61HC31N4 ATV71HC20N4...HC28N4 ATV71HC20Y ATV61/71HC25Y, HC31Y ATV61HC40Y ATV61HC25N4...HC31N4 with VW3A7101 braking transistor ATV71HC20N4...HC28N4 with VW3A7101 braking transistor ATV71HC20Y ATV61/71HC25Y, HC31Y ATV61HC40Y Profibus Option Type 1 cover for Profibus Option Card 230V Drive controllers 480V Drive controllers Card Cover ATV61H c ATV71H ATV61H ATV71H 075M3 037M3 075N4 075N4 U15M3 075M3 U15N4 U15N4 U15M3 U22N4 U22N4 U22M3 U22M3 U30N4 U30N4 U30M3 U30M3 U40N4 U40N4 U40M3 U40M3 U55M3 U55M3 U55N4 U55N4 U75N4 U75N4 U75M3 U75M3 D11N4 D11N4 D11M3X D11M3X D15N4 D15N4 D15M3X D15M3X D18N4 D18N4 c The symbol indicates the part of the number that varies with controller size or rating.
VW3A9515
1062.
VW3A9201 VW3A9202 VW3A9203 VW3A9204 VW3A9205 VW3A9206 VW3A9207 VW3A9217 VW3A9208 VW3A9209 VW3A9210 VW3A9211 VW3A9212
45. 45. 45. 45. 45. 65. 65. 85. 135. 460. 553. 573. 588.
VW3A9213
604.
VW3A9214
604.
VW3A9201PF
101.
CP4C
Discount Schedule
26-11
26
AC DRIVES
Enclosed Drives
EFlex AC Drives
Class 8839 / Refer to Brochure 8800BR0501
www.schneider-electric.us
Variable Torque AC Drive208, 230 V and 460 V Ratings hp 208 V 1 2 4.6 7.5 10.6 16.7 24.2 30.8 46.2 59.4 74.8 88 114 143 Modifications Control 8839 EFD 1 2 3 4 V 5 6 A07 7 8 9 Lights Misc Output Amperes 230 V 4.2 6.8 9.6 15.2 22 28 42 54 68 80 104 130 460 V 2.1 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124
AFC
AFC
3 5
7.5 10
Power Circuit W
Power Circuit Y
15 20 25 30
26
AC DRIVES
Note: Standard packages are rated 100 k AIC
Table 26.8:
2 hp Code
208/230 V
G=Type 1 A=Type 12K H=Type G=Type 1 A=Type 12K H=Type 3R 3R $ Price C=1 D=2 E=3 F=5 G = 7.5 H = 10 J = 15 K = 20 L = 25 M = 30 N = 40 P = 50 Q = 60 R = 75 S = 100 Included 155. 155. 155. 155. 155. 155. 362. 362. 362. 362. 362. 362. 1500. 1500. 1500. 1500. 1700. 1700. 2625. 2625. Included 2625. 3750. 3750. 3750. $ Price 155. 155. 155. 155. 155. 155. 155. 155. 155. 362. 362. 516. 516. 516. 516.
$ Price 216. 235. 235. 253. 298. 382. 394. 478. 478. 497. 560. 729.
26-12
CP4C
Discount Schedule
Enclosed Drives
www.schneider-electric.us
EFlex AC Drives
Class 8839 / Refer to Brochure 8800BR0501
7 Control Options A07fn HandOffAuto, Speed Pot. B07f C07a HandOffAuto, StartStop, Speed Pot. StartStop, Speed Pot. Included 100. 75. N/C 100.
8 Light Options A08bn Power On, Run, Fault, Auto Lights 80. 80. 65.
9 Miscellaneous Options A09 5% Line Reactor option See Table 26.8 See Table 26.8 180. -40. 80. 400. 150. N/C 140. 400. 165. 165. 165. 165.
B08 bc Power On, Run, Fault, Bypass Lights C08b j Power On, Run, Fault Lights
B09dp Line Contactor C09i D09l E09e F09m H09j J09k K09 L09m M09m O09m P09m Q09m R09m S09o T09 q U09 315 PSI Transducer Omit Keypad Smoke Purge (Firemans Override) Profibus DP I/O Extension Card, 020 mA Output Input programmed for 010 Vdc cUL Listing Certification LonWorks Card Modbus / Unitelway Card Apogee P1 Card Metasys N2 Card Ethernet TCP/IP BACnet Card End Damper Control Service entrance rating Seismic Qualification DeviceNet Option Card
D07fh HandOffComm, Speed Pot. E07fh HandOffComm, StartStop, Speed Pot. N07 a b c d e f g h i No operators; wired for remote operation
k 100. l m
Control Option C07 (StartStop, Speed Potentiometer) is not compatible with Power Circuit Y Bypass or Light Option A08 or B08. Light Options A08, B08 and C08 cannot be selected together. Select only one. Light Option B08 (Power On, Run, Fault, Bypass) is not compatible with Power Circuit W Without Bypass. Misc. Option B09 Line Contactor is not compatible with Power Circuit W (Without Bypass). Misc. Option E09 Smoke Purge (Firemans Override) permits motor to run at full speed. HandOff Auto switch must be placed in off position for AFC fault reset. When Power Circuit Y Bypass selected, AFC OffBypass switch and TestNormal switch is supplied. When communication options are selected, Control Option D07 or E07 must be selected for control. Misc. Option C09 315 PSI Transducer is not compatible with Control Options C07, D07 or E07, J09 010 Vdc Auto Speed Reference Option, H09 I/O Extension Card, F09, L09, M09, O09, P09, Q09, R09 Serial Communication Cards.
n o
p q
V09
CP4C
Discount Schedule
26-13
26
AC DRIVES
Misc. Option H09 I/O Extension Card is not compatible with C09 315 PSI Transducer or Serial Communications Cards F09, L09, M09, O09, P09, Q09, or R09. Misc. Option J09 input programmed for 010 Vdc is not compatible with Control Options C07, D07 or E07 Control Options or Misc. Option C09 315 PSI Transducer. Omit the Keypad Option D09 from Enclosure Door. User must buy a separate device to program the controller inside. Serial Communication Options F09, L09, M09, O09, P09, Q09, R09 cannot be selected together. Select only one. Serial Communications and Misc. Option H09 are not compatible. Control Option D07 or E07 must be selected for monitoring and control with Serial Communication Options. Light Option A08 is compatible with Control Options A07, B07, D07 and E07. Misc. Option S09 End Damper Control is not compatible with Control Options D07 Hand OffComm, Speed Pot. Or E07 HandOff Comm, StartStop, Speed Pot. Misc. Option B09 Line Contactor is not compatible with H03 Type 3R Enclosure. Option T09 service entrance rating and K09 (cUL) are mutually exclusive.
165.
Enclosed Drives
SFlex AC Drives
Class 8839 / Refer to Brochure 8800BR0501
www.schneider-electric.us
Table 26.9:
26
AC DRIVES
S-Flex 21 Enclosed Drive Controller Type 1 Rated +14 to +140 F (-10 to +40 C)
Table 26.10:
Miscellaneous Options a
Option Number $ Price
Description
BACnet Communication Card A06 185. LonWorks N2 Communication Card B06 375. Metasys N2 Communications Card C06 185. Apogee FLN P1 Communications Card D06 185. Modbus Monitoring N06 N/C Seismic Qualification S07 215. a Miscellaneous Options A06, B06, C06, and D06 are mutually exclusive. Add Misc. Option number to S-Flex 21 Catalog Number when ordering communications card factory installed.
Table 26.11:
Accessories
Catalog Number $ Price
Description
Altivar 21 PCSoft software PC Soft Test and Commissioning Software. For use with Microsoft Windows 95, 98, NT, VW3A2104 b XP, and Vista operating systems for PCs only. (Cable not included) PC Cable for Test and Commissioning Software Includes 3-meter (9.8 ft.) cable, VW3A8106 RS-485/RS-232C adaptor and connectors EZ-M Mounting Channel, 72" length EZM72MC b Free downloaded at www.us.telemecanique.com.
N/C
75. 42.
Altivar 21 power converter Square D circuit breaker disconnect (460 V version also includes power fuses) UL508C coordinated short circuit rating for 100,000 A Adjustable Frequency Controller-Off-Bypass selector switch Local/Remote configurable on controller Power On red LED Bypass Run green LED Fire/Freezestat interlock for Adjustable Frequency Drive and Bypass mode Form C Adjustable Frequency Controller fault auxiliary contact Modbus RJ-45 communication port Smoke purge Function Bypass Run Auxiliary Contact Drive Run Auxiliary Contact Full Voltage Bypass Power Circuit with overload relay 120 Vac fused control power transformer
26-14
CP4C
Discount Schedule
Table 26.12:
A 6 9 12 22 32
ATSU01N2 Family Selection and Pricing For use with TeSys Uline motor starter (24 Vdc control power)
Catalog Number ATSU01N206LT ATSU01N209LT ATSU01N212LT ATSU01N222LT ATSU01N232LT 0.751.1 kW 1.5 kW 2.23 kW 45.5 kW 7.5 kW 230 V Three-Phase Motor Power 400 V 11.5 hp 1.52.2 kW 2 hp 34 kW 3 hp 5.5 kW 57.5 hp 7.511 kW 10 hp 15 kW 460 V 23 hp 5 hp 7.5 hp 1015 hp 20 hp $ Price 133. 152. 175. 219. 300.
NOTE: The ATSU01N2 soft start must be externally supplied with 24 Vdc control power. If this is not available, select from the ATS01N2 table below. The ATSU01N2 soft start is shipped with a custom ATSU01N2 to TeSys Uline power connector. Table 26.13:
A
ATS01N2 Family Selection and Pricing For use with TeSys Uline a, GV2, GV3, and other motor starters
Catalog Number 230 V Three-Phase Motor Power 400 V 1 / 1.5 hp 2 hp 3 hp 5 / 7.5 hp 10 hp 1.5 / 2.2 kW 3 / 4 kW 5.5 kW 7.5 / 11 kW 15 kW 460 V 2 / 3 hp 5 hp 7.5 hp 10 / 15 hp 20 hp $ Price 133. 152. 175. 219. 300. 133. 152. 175. 219. 300. 133. 152. 175. 219. 300.
6 ATS01N206LU 0.75 / 1.1 kW 9 ATS01N209LU 1.5 kW 12 ATS01N212LU 2.2 / 3 kW 22 ATS01N222LU 4 / 5.5 kW 32 ATS01N232LU 7.5 kW 6 ATS01N206QN 9 ATS01N209QN 12 ATS01N212QN 22 ATS01N222QN 32 ATS01N232QN 6 ATS01N206RT 9 ATS01N209RT 12 ATS01N212RT 22 ATS01N222RT 32 ATS01N232RT a No separate control voltage is needed.
Table 26.14:
Accessory
Description Catalog No. VW3G4104 $ Price 10.
Custom power connector (between ATS01N2 and TeSys Uline motor starter)
CP1G
Discount Schedule
26-15
26
AC DRIVES
Single or three-phase motors rated for 3 to 12 A at 110, 208, 230, 400, and 460 volts
Soft start (no soft stop) Motor voltage Three-phase motor Single-phase motor External control power Internal shorting contactor Application Adjustments LED display Plugin control terminals 15 second ramp 110, 208, 230, 400, 460 1/2 to 7.5 hp 1/4 to 2 hp 24 Vac/dc or 110230 Vac 9 and 12 A modelscool, reliable operation Derate for temperature > 40C, altitude > 1000 m (see ATS01 Catalog 8637CT0401 for more detail) Start time (15 s) and initial (starting) voltage (3080%) Two: Power ON and Full Voltage (up to speed) 9 and 12 A modelsease of wiring
Table 26.15:
A
Catalog Number ATS01N103FT ATS01N106FT ATS01N109FT ATS01N112FT 110 V 1/4 hp 1/3 hp 1/2 hp
26
AC DRIVES
3 6 9 12
1/4 hp 1/2 hp 1 hp 2 hp
Table 26.16:
Accessory
Description Catalog No. RHZ66a $ Price 3.60
DZ5 MB DIN rail ( 4 ) adaptor for 3 and 6 A models (sold only in packages of 10) a Discount Schedule I.
Table 26.17:
A 32 44 72 85
Table 26.18:
Description
Accessories
Catalog No. LAD8N11b VY1H4101 $ Price 20.70 25.00
Up to Speed auxiliary relay contact (attaches to side of ATS01) DIN rail adaptor (32 and 44 A models) b Discount Schedule I12.
26-16
I12
CP1G
Discount Schedule
Open Style Soft Starts 5060 Hz, Three-Phase, 690 V MaximumAC3 Duty
The Altistart 48 soft start must be selected using the table below, based on nameplate full load ampere rating of the motor. The horsepower ratings shown in table are for reference only. Table 26.19:
208 V
NOTE: For severe duty or high inertia loads, derate by 1 hp size. Table 26.20: Altistart 48 Options
Description Remote Keypad Display Mounting Kit, including: Catalog Number $ Price
Keypad with 3character 7segment display IP65 cover and seal, mounting screws, and 3 meter cable to connect keypad display to Altistart 48
VW3G48101
165.
Cover for power terminalsSet of 6 for ATS48C14Y and ATS48C17Y Cover for power terminalsSet of 6 for ATS48C21Y, ATS48C25Y, and ATS48C32Y Ethernet Bridge DeviceNet Gateway Profibus DP Gateway FIPIO Gateway 1/3 meter connection cable (RJ45 to RJ45) 1 meter connection cable (RJ45 to RJ45) 3 meter connection cable (RJ45 to RJ45) 1/3 meter splitter cable (For RJ45 daisy chain connection) 1 meter splitter cable (For RJ45 daisy chain connection) RJ45 terminator (2 per package) Modbus hub (Eight RJ45 ports) Powersuite commissioning software on CDc PowerSuite upgrade CD from most recent to new versionc PC connection kit. To connect PC to Altistart 48 soft startc Pocket PC connection kit. To connect JORNADA or iPAQ PPC to Altistart soft start c Size M10 Bolt Kit Size M12 Bolt Kit c For more information, see Data Bulletin 8806DB0001. d Use discount schedule I12 e Use discount schedule PC41 f discount schedule I11 g discount schedule CP4C
LA9F702 d LA9F703 d 174CEV30020 e LUFP9 f LUFP7 f LUFP1 f VW3A8306R03 VW3A8306R10 VW3A8306R30 VW3A8306TF03 VW3A8306TF10 VW3A8306RC LU9GC3 f VW3A8104 g VW3A8105 g VW3A8106 g VW3A8111 g W808780210111 W808780220111
61. 82. 1027. 495. 495. 495. 20. 25. 30. 75. 85. 6. 208. 150. 98. 75. 95. 8. 10.
CP1G
I12
PC41
I11
CP4C
Discount Schedule
26-17
26
a b
3 5 5.5 10 15 5 7.5 7.5 15 20 7.5 10 11 20 25 10 15 25 30 15 18.5 30 40 15 20 22 40 50 20 25 30 50 60 25 30 37 60 75 30 40 45 75 100 40 50 55 100 125 50 60 75 125 150 60 75 90 150 200 75 100 110 200 250 100 125 132 250 300 125 150 160 300 350 150 220 350 400 200 250 400 500 200 250 315 500 600 250 300 355 600 800 350 350 400 800 1000 400 450 500 1000 1200 Motor full load amperage (FLA) must not exceed the ampere rating of the soft start. Low InertiaConnected motor load inertia equal or less than 10 times motor rotor inertia. High InertiaConnected motor load inertia greater than 10 times motor rotor inertia.
AC DRIVES
AC Drives
Information and Selection
For information and selection, contact your nearest Schneider Electric sales office or visit our website: www.schneider-electric.ussp
Technical Support
Drive Product Support Group When troubleshooting the Altivar 61/71 PowerGard drive controller, discuss the symptoms of the reported problems with operating personnel. Ask them to describe the problem, when they first observed the problem, and where the problem was seen. Observe directly the drive system and process. For support and assistance, contact the Drive Product Support Group. The Drive Product Support Group is staffed from 8:00 am until 6:00 pm Eastern time to assist with product selection, startup, and diagnosis of product or application problems. EMERGENCY Technical phone support is available 24 hours a day, 365 days a year.
Toll Free: Email: Fax:
26
AC DRIVES
Services (OnSite) Square D Services is your single source of service expertise for all major brands of electrical equipment. With our national network of service locations and qualified experts, Square D Services is capable of providing customerbased solutions anywhere in the United States. Services responds to your requests, seven day a week, 24 hours a day.
Toll Free:
888SquareD (8887782733)
Customer Training
Schneider Electric offers a variety of instructor-led, skill enhancing and technical product training programs for customers. For a complete list of drives/soft start training with dates, locations, and pricing, please call:
Phone: Fax:
978-975-9306 978-975-2821
Product Literature
To view or download product literature, visit the Schneider Electric web site: www.schneider-electric.us
26-18
Table of Contents
Section 27
Automation Products
Programmable Logic Controllers
Twido Modicon TSX Micro Modicon M340 Modicon Premium Modicon Quantum
Magelis XBTGT (p.27-3)
27-2 27-2 27-2 27-2 27-2 27-3 27-3 27-3 27-2 27-2 27-5
HMI/SCADA
New!
Magelis XBTN/R Magelis XBTRT Magelis XBTGT Magelis XBTGK Magelis XBTGTW Magelis Industrial PCs Magelis Smart Magelis Compact iPC
27-3 27-3 27-3 27-3 27-3 27-4 27-4 27-4 27-4 27-4 27-4
AUTOMATION PRODUCTS
New! New!
New! New!
Distributed I/O
Advantys OTB
New! New! New! New!
Advantys STB Advantys Telefast ABE7 Sub-bases, IP20 Advantys Telefast ABE9 Passive splitter boxes, IP67 Advantys FTB monobloc I/O splitter boxes, IP67 Advantys FTM modular I/O splitter boxes, IP67 Modicon Momentum
For more detailed information, please refer to the catalogs referenced with each product or the catalog Automation and Control The Essential Guide (DIA1ED2040506EN-US). You can also visit our website at http://www.schneider-electric.us.
27-1
27
Automation Products
www.schneider-electric.us
Modicon Quantum
The Quantum is our high-end, full function PLC designed for high I/O count industrial applications that require high performance such as Pharmaceutical, Petrochemical, Food & Beverage, Automotive, and others. Quantum also offers true bumpless hot standby. Quantum processors can be programmed with Unity Pro. Concept and ProWORX 32 are also supported on the Quantum platform.The Unity Quantum's onboard memory can exceed 3 Mbytes. The Unity Quantums can have more than 7 Mbytes of extended memory on a PCMCIA card for data and application storage combined. They can have over 8 Mbytes of just data storage. The newest offer in the Quantum product line is the SIL2 Quantum. This includes both standard and hot standby capability as well as redundant I/O. It also programs with Unity Pro XLS. The SIL2 offer stresses both high reliability as well as high availability. More details are available at www.Schneider-Electric.us or in catalog number MKTED204071EN. Information about the SIL2 Quantum is available in the brochure 8000BR0808.
Modicon M340
Our latest midrange PLC is the most integrated ever! Highly requested by OEMs, the all-power-inside concept boasts high-performance processing and small size to create a system that provides flexibility beyond any before. With up to 3 built-in CPU communication ports, large memory options, 64 channel high-density modules, and embedded web-servers, the Modicon M340 is a powerful solution for OEMs demanding more productivity in their PLCs. The Modicon M340 PLC is programmed with Unity Pro software, which allows users to dramatically reduce setup time and effort with features like drag 'n drop CANopen bus setup and standard IEC 61131-3 language selection. Designers gain fast, easy and efficient startups. More details are found on our website or in the latest Modicon M340 catalogs and brochures.More details are available at www.SchneiderElectric.us or in catalog DIA1ED2040506EN-US.
27
AUTOMATION PRODUCTS
New!
Modicon Premium
Ideally suited for discrete manufacturing and complex OEM applications, this costeffective PLC line features integrated functions such as weighing, interpolated motion control, and process loops. Using the built-in Ethernet port, user-customized web page capabilities, and a range of popular Open-standard fieldbus connections the Modicon Premium enables seamless communication with enterprise systems providing low-cost remote maintenance diagnostics. More details are available at www.Schneider-Electric.us or in catalog MKTED204072EN.
Unity Application Generator is an advanced design and generation software tool that integrates multiple PLCs and HMI/SCADA systems to provide an automation solution similar to a Distributed Control System. UAG supports structured project design by providing a software tool to bridge from the process engineer to the control/automation designer (from the P&ID to the automation system). UAG will capture and re-use the Customer's best practices within application-specific libraries that reduce the dependency on experts and enable standardization and increases software robustness. Single database entry avoids duplicate effort and resulting errors. Automatic Application Generation including the automatic configuration of networks in multi device systems increases efficiency, improves software quality, speeds commissioning while simultaneously reducing project risk. Integrated change tracking and automatic documentation generation reduces engineering effort and enables system validation. UAG integrates Unity PLCs (M340/Premium/Quantum), Vijeo Citect, Connectors for leading HMI/SCADA systems, Modbus TCP/IP communication and OFS/OPC. Additional information can be found at www.schneider-electric.us.
27-2
Automation Products
www.schneider-electric.us
Magelis XBTGT
Available in six sizes (3.8, 5.7, 7.4, 10.4, 12.1 and 15 inches) and 4 function levels, the Magelis XBTGT graphical touch screen terminals are designed to fit all your HMI application needs. Some offer: multimedia capability with a large processing capacity; openness with unequalled connectivity via numerous communication ports and multilink communication for simultaneous equipment control; ease-of-use with simple installation and simple configuration with Vijeo Designer software. The entire product range is RoHS compliant. More information is available by visiting http://www.us.schneider-electric.com/HMI.
ProWORX 32
ProWORX 32 is the simple programming solution to program your Modicon PLCs using 984 ladder logic programming. Compatible with 584, 984, Modicon Micro, Momentum, Compact, and Quantum. Schneider Electric Automation Services maintains the tools necessary to upgrade your ProWORX 32 application to a Unity Pro application with ladder logic that is designed to mirror the 984LL application. More information is available in catalog number DIA1ED2040506EN-US, Automation and Control The Essential Guide. Additional information can be found at www.Schneider-Electric.us.
Magelis XBTGK
With three models to choose from New! and two sizes screen sizes, 5.7 and 10.4 inches, the Magelis XBTGK offers a lot of flexibility. The XBTGK uses the same technology of the popular XBTGT but adds a keypad and industrial mouse pointer for extra control and data input that can be configured to operate simultaneously with or without the touchscreen. In a dusty or dirty environment, the keypad enables the use of the terminal, even while wearing gloves. There is an extra added safety feature where two keys can be simultaneously pressed to ensure command order security and the keys can be locked during delicate phases of an operation. Vijeo Designer, the single software package for the entire Magelis Advanced Panel range, ties the solution together. More information is available by visiting http://www.us.schneider-electric.com/HMI.
Magelis XBTN/R
The Magelis XBT-N and R matrix screen text display units accommodate up to four lines of large font (20 mm high) text for easy viewing. Rated for IEC 60529, NEMA 4X outdoor use, Class I Div II and UL508, the sturdy Magelis XBT-N and R displays feature an ergonomically designed keyboard with up to 20 keys and ports to handle either point-to-point or multipoint communications. A truly global solution, the XBT-N and R displays provide low-cost connectivity to all Schneider Electric PLCs using Modbus and Unitelway protocols, support Latin, Cyrillic, Katakana, Greek and Chinese fonts, and six languages. More information is available in catalog by visiting http://www.us.schneiderelectric.com/HMI.
Magelis XBTGTW
Available in two color touch New! screens sizes, 8.4 and 15 inches, the Magelis XBTGTW terminals offer a Windows environment open to the Web (local and remote diagnostic and maintenance functions) and multimedia applications (streaming video on IP, Webcam management, sound and an integrated video output). With this open platform, the XBTGTW allows you to enhance your HMI applications with Vijeo Designer, while providing total access to Microsoft Office software (Excel, Word, PowerPoint, etc) and data editing with Office Viewer or Acrobat Reader, two pre-installed applications. The front panel USB port provides connectivity for peripherals. Numerous communication interfaces such as dual-Ethernet, multiple USB ports and slots provided for PCMCIA (15) and Compact Flash slots are available. More information is available by visiting http://www.us.schneider-electric.com/HMI.
AUTOMATION PRODUCTS
Magelis XBTRT
New!
The Magelis XBT-RT semi-graphic touch screens accommodate up to ten lines of 33 characters of text. Rated for NEMA 4X, Class I Div II and UL508, the sturdy Magelis XBT-RT displays semi-graphic objects, bar graphs, curves, buttons, and bitmaps and has ports to handle either point-to-point or multipoint communications. With the ability to choose between touch screen and keypad combination or keypad only operation, the XBT-RT, is adaptable. Like the other Magelis small panels, the XBT-RT displays provide low-cost connectivity to all Schneider Electric PLCs using Modbus and Unitelway protocols and several major third party protocols and supports multiple languages, including Japanese, Cyrillic, Greek and Chinese. More information is available by visiting http://www.us.schneider-electric.com/HMI.
27-3
27
Automation Products
www.schneider-electric.us
Magelis Products
MagelisIndustrial PCs
The Magelis Industrial PC (iPC) range offers All-In-One or BOX industrial PC for autonomous or distributed applications. The Magelis iPC provides the openness and ergonomics of a Windows environment in a rugged PC that is ready for tough industrial environments. With the Magelis iPC range, you will be sure to find the PC that corresponds exactly to your specifications.
To complete the configuration: To convert the Flex PC BOX into an 'All-in-one' PC, add a 15 or 19" Front Panel in touch version or 12 or 15" Front Panel in touch/keyboard version To connect a remote screen to the PC BOX (Smart, Compact, or Flex), add a 15 or 19" iDisplay in touch version or 15" iDisplay in touch /keyboard version. More information is available by visiting http://www.us.schneider-electric.com/HMI.
Vijeo Designer
Vijeo Designer configuration software can be used to create HMI applications designed for controlling automation systems for the Magelis XBTGT/XBTGK/XBTGTW/iPC. Its the ideal design tool for the simplest control application right up to the most complex HMI installations. It offers advanced script functions for customizing your HMI to meet the strictest specifications. More information is available by visiting http://www.us.schneider-electric.com/HMI.
Vijeo Citect
The flexibility of Vijeo Citect supervisory control and data acquisition (SCADA) software enables users to achieve the solution that best suits their supervision requirements for installations. Vijeo Citect offers all the functions of a modern supervisor. Its distributed client-server architecture is applicable to a multitude of applications in the most varied domains: Energy and infrastructures: airports, roads and tunnels, water wastewater, oil and gas, etc. Industries: food and beverage, mining, metals, minerals, system integrator, etc.
New!
New!
Available in 8.4, 12, or 15 inches, the Magelis Compact iPC provides data storage adapted to industrial needs, Industrial HDD disk or 8 or 16 GB Flash disk (15) only. This panel PC has several extension options, including: 1 PCI slot, dual-Ethernet ports, one with gigabit support, 4 or 5 USB ports, 2 serial ports and a PCMCIA slot. Vijeo Designer HMI software transforms the iPC into an operator terminal with the advantages of Windows openness (HMI Edition).
27
AUTOMATION PRODUCTS
This development tool enables the development of any supervision application, from small stand-alone systems to large distributed redundant systems. More information is available by visiting http://www.us.schneiderelectric.com/HMI.
Vijeo Historian
New!
Vijeo Historian, a data logging and reporting software, collects, compares, and records the entire flow of data on a common platform. By establishing the communication between the supervisory systems (SCADA) and database systems, such as Oracle and SQL, Vijeo Historian enables collection and management of the production data and its availability for a vast range of client processing applications. More information is available by visiting http://www.us.schneider-electric.com/HMI.
Magelis Compact PC BOX: 1 PCI slot and the same qualities as the Compact IPC Magelis Flex PC BOX 2 or 4 PCI slots Industrial HDD 24/7 and/or 8 or 16 GB disk Intel Celeron M 440 with 1.86 GHz or Pentium Core Duo with 2 GHz 100-240 Vac or 24 Vdc power supply
27-4
Automation Products
www.schneider-electric.us
Advantys OTB
The open and modular new Advantys OTB distributed I/O system offers an ideal solution for IP20 optimizedtype distributed input/output requirements. Users can create I/O islands managed by a master controller, via a fieldbus or communication network. It includes three communication bases for the Various types of fieldbus: CANopen, Ethernet TCP/IP, or Modbus RS 485 serial. Discrete or analog I/O are available. More information is available in catalog number DIA3ED2040801EN-US.
Advantys STB
The Telemecanique Advantys STB is a highly modular distributed I/O platform, integrated wiring solution, and power management system that delivers the effective and targeted control available. With an open network adaptable to most major field buses, a flexible island I/O structure, and simple configuration via the STBSUP1000 software, Advantys STB is the right choice. More information is available in catalog number MKTED204101EN-US.
Modicon Momentum
The small footprint and open architecture of the Momentum PLC product line make it extremely versatile for a variety of automation applications. The Momentum PLC is ideal for PC-based control, distributed control, distributed I/O, and traditional, standalone PLC control. Momentum PLC options and accessories include: I/O bases, processor adapters, option adapters and communication adapters that are interchangeable and snap together to deliver optimal flexibility throughout the control system lifecycle. Using Ethernet as its communications backbone, the Modicon Momentum M1E Processor delivers all the performance benefits of real-time control. The open architecture of the M1E processor make it the first truly universal controller for distributed I/O, compatible with many of the major fieldbus and control network environments. An integral Ethernet port in the M1E allows users to perform a wide range of functions over Ethernet, including data acquisition, peer-to-peer communications, and I/O scanning. Five embedded web pages enable the use of a standard web browser to read status and diagnostic information from the processor. The most recent addition to the Momentum product offer is the Momentum M1E ConneXium switch. This model combines the power and functionality of the M1E processor with the communication versatility of four Modbus Ethernet TCP/IP ports. The award winning M1E not only seamlessly connects I/O and other control devices via open standards; it delivers the performance of a full function, real-time controller for stand-alone and distributed system configurations in one money-saving unit. Additional information can be found at www.Schneider-Electric.us or in catalog MKTED205061EN.
27-5
27
AUTOMATION PRODUCTS
Automation Products
ConneXium Ethernet Products
The ConneXium line of networking products offers a complete range of Ethernet switches (managed and unmanaged), hubs, transceivers, gateways, cabling, and diagnostic monitoring software for demanding industrial environments. With fiber and redundant capabilities, along with advanced filtering and security features, ConneXium improves the performance and safety of the network. More details can be found on our website www.transparent-ready.com or in catalog MKTED205102EN-US.
ConneXium Products
www.schneider-electric.us
TRANSPARENT READY
Transparent Ready products cover solutions in Industrial automation to electrical Distribution, and are based on universal Ethernet TCP/IP and Web technologies. They provide seamless communication between plant floor devices, like PLCs, drives, and MCCs, with corporate business systems. Use of the open Modbus TCP/IP protocol, which is the leading industrial Ethernet protocol, broadens the scope of dedicated machine diagnostics to remote management. Choosing Transparent Ready means opting for flexible, open automation architectures. More details can be found on our website www.transparent-ready.com or in catalog MKTED205102EN-US.
Increased overall productivity with easy-to-use diagnostics Expanded functionality offered with the Device Type Editor, including adding third-party devices to the library and adding unique device names for increased recognition An intuitive and ergonomic design that minimizes enduser training and decreases maintenance costs
27
AUTOMATION PRODUCTS
27-6
Automation Products
www.schneider-electric.us
The recognition of Ethernet TCP/IP, both in organizations and on the internet, has made it the communication standard of today. Its wide use is leading to a reduction in connection costs, increased performance and the addition of new functions, which all combine to ensure its durability. Ethernet TCP/IP meets the connection requirements of every application: Twisted pair copper cables for simplicity and low costs Optical fiber for immunity to interference and for long distances Communication redundancy, inherent in the IP (internet protocol) Remote point-to-point access via the telephone network or the Internet for the cost of a local call Ethernet TCP/IP, a truly open technology, supports all type of communication: Web pages File transfer Industrial messaging, etc. With its high speed, the network no longer limits the performance of the application. The architecture can evolve without any difficulty. The products or devices remain compatible, ensuring the long-term durability of the system. More information on Ethernet and Ethernet Products is available in catalog number MKTED204121EN.
27-7
27
AUTOMATION PRODUCTS
Automation Products
27
AUTOMATION PRODUCTS
27-8
SUBSTITUTION: Square D may furnish suitable substitutes for material unobtainable because of priorities or regulations established by governmental authority or nonavailability of materials from suppliers, provided such substitutions do not adversely affect the technical soundness of the equipment. Square D assumes no liability for deviation from published dimensions and descriptive information not essential to proper performance of the product. TAXES: Any manufacturer's tax, retailer's tax, occupation tax, use tax, sales tax, excise tax, (except federal excise tax on vehicles), duty, customs, inspecting or testing fee, or other tax, fee or charge of any nature whatsoever, imposed by any governmental authority or measured by any transaction between Square D and Purchaser, shall be paid by the Purchaser in addition to the prices quoted or invoiced, and such charges will appear as a separate line item on the invoice. In the event Square D will be required to pay any such tax, fee, or charge, Purchaser shall reimburse Square D or, in lieu of such payment, Purchaser shall supply Square D at the time the order is submitted with an exemption certificate or other document acceptable to the tax authority. Purchase Orders must state the existence and amount of any such tax, fee or charge for which Purchaser claims an exemption. TERMS OF PAYMENT: Acceptance of all Purchase Orders is subject to Purchaser meeting Square D credit standards. Terms are subject to change for failure to meet such standards. Terms are net thirty (30) days from date of invoice of each shipment, unless otherwise stated in Square D's quotation. For an authorized distributor or authorized reseller order, applicable terms of payment are stated in the quotation or applicable discount schedule. Square D reserves the right at any time to demand full or partial payment before proceeding with a contract of sale if, in its sole judgment, as a result of changes in the financial condition of the Purchaser the terms of payment originally specified are no longer justified. PAYMENTS: If delivery is delayed or deferred by the Purchaser beyond the scheduled date, payment shall be due in full when Square D is prepared to ship. The equipment may be stored at the risk and expense of the Purchaser. If the Purchaser defaults when any payment is due, then the whole contract price shall become due and payable upon demand, or Square D at its option, without prejudice to other lawful remedies, may defer delivery or cancel the contract for sale. If Purchaser become insolvent, or bankrupt or in the event any proceeding is brought against the Purchaser, voluntarily or involuntarily under the bankruptcy or any insolvency law, Square D may cancel any order then outstanding at any time and recover its proper cancellation charges from the Purchaser or the Purchaser's estate. DELIVERY: F.O.B. POINT OF SHIPMENT: When the Square D quotation is based on delivery F.O.B. point of shipment, freight prepaid and allowed for delivery within the continental United States, Product is sold F.O.B. point of shipment, freight prepaid and allowed for orders over $2000 net. Delivery by Square D to the point of shipment constitutes delivery to the Purchaser; and title and all risk of loss or damage in transit shall pass to the Purchaser at time of delivery at the F.O.B. point. Square D is not responsible for breakage or delays by carrier after having received in good order receipts from the carrier. Purchaser is responsible for pursuing any damage claims with the carrier. For orders under $2000 net the above terms apply except freight is prepaid not allowed. No allowance will be made in lieu of transportation if the Purchaser accepts shipment at factory, warehouse or freight station or otherwise supplies its own transportation. Freight prepaid is defined as: a) Shipments to destinations within the continental United States to the accessible common carrier point nearest the first destination. b) Shipments to U.S. destinations outside the continental United States shall be to the common carrier free delivery point in the United States nearest the original port of embarkation. All charges associated with F.A.S., C.I.F., or other charges such as pier transfer, lift, ocean freight, and marine or war insurance shall be paid by the Purchaser, unless otherwise specifically agreed in a specific Purchase Order. In no event will Square D be responsible for demurrage or detention charges. DELIVERY: F.O.B. DESTINATION: When the Square D quotation is based on delivery F.O.B. Destination, for shipments for delivery within the continental United States, Square D will retain title and all risk of loss or damage in transit to the common carrier free delivery point in the United States nearest the first destination for a price addition of 2% of the net price. If the Purchaser elects this Option, Purchaser's obligations shall be as follows: a) Purchaser shall have the responsibility of inspecting the equipment for apparent loss or damage immediately upon its arrival at the free delivery point. b) In the event of apparent shipping loss or damage, Purchaser shall make written notation of the loss on the carrier's delivery receipt and, within 72 hours of delivery shall notify the Square D Customer Information Center. Purchaser shall not remove product from the point of examination and shall retain the shipping container and packing material. Purchaser shall request the carrier to make an inspection and send Square D a copy of the carrier's inspection report. c) In the event of concealed damage which occurred during transit and is discovered by the Purchaser after delivery, Purchaser shall report such damage immediately, but in no event later than 15 days after delivery, to the delivering carrier, and within 72 hours of discovery, shall notify the local Square D field office. If such notification is not made, Square D shall not be liable for loss or damage in transit. SHIPMENT AND ROUTING: Square D shall select the point of origin of shipment, the method of transportation and the routing of the shipment. Purchasers that request expedited or special modes of transportation or routing involving air, premium or any other non-standard Square D shipping shall be assessed additional charges for shipping, handling, freight and expediting. Any rebates, allowances, discounts, or incentives received by Square D from its carriers shall be retained by Square D. All prices include domestic packaging only. When other than domestic packaging is required, contact your local Square D field office. Purchaser specified packaging and marking may be subject to additional charges. SHORTAGES: Claims for shortages or errors must be submitted to Square D within 30 days after invoice date, and failure to give such notice shall constitute unqualified acceptance and a waiver of all such claims by the Purchaser. INSTALLMENTS: Square D reserves the right to make shipments in installments, unless otherwise expressly stipulated in a specific Purchase Order; and all such installments when separately invoiced shall be paid for when due per invoice without regard to subsequent shipments. Delay in shipment of any installment shall not relieve Purchaser of its obligation to accept remaining shipments.
INTELLECTUAL PROPERTY: As to equipment proposed and furnished by Square D, Square D shall defend any suit or proceeding brought against Purchaser so far as based on a claim that such equipment constitutes an infringement of any copyright, trademark or patent of the United States.
Square D Conditions of Sale Standard NOTE:The following Conditions of Sale are subject to change. All transactions for products sold by Square D Company are subject to the latest published Conditions of Sale of the Square D Company and to any Special Conditions of Sale which may be contained in applicable Square D quotations and acknowledgments.
1. GOVERNING PROVISIONS AND ACCEPTANCE: All quotations are subject to these conditions of sale. Acceptance of an order by Square D shall be expressly conditioned on Purchaser's assent to these conditions. Purchaser's direction to proceed with engineering, manufacture or shipment by Square D shall be deemed evidence of this assent. No modified or other conditions will be applicable unless those conditions are so stated in Square D's proposal or are specifically agreed to in writing and signed by an authorized official of Square D. Failure to object to provisions contained in any Purchase Order or other communication from the Purchaser (including, without limitation, penalty clauses of any kind) shall not be construed as a waiver of these Conditions nor an acceptance of any other provisions. These terms are a complete statement of the parties' agreement and may only be modified in writing signed by both parties. These terms may not be modified by course of dealing, course of performance or usage of trade. These terms supersede all previous written or oral quotations, statements or agreements. Any contract for sale by and between the parties shall be governed by and construed according to the laws of the State of Illinois without regard to its rules on the conflict of laws. The Convention on the International Sale of Goods is expressly excluded. QUOTATIONS: Quotations shall be valid for no more than thirty (30) days from their date, unless otherwise stated in the quotation. All quotations are subject to change by Square D Company at any time upon notice to Purchaser. It is Purchaser's obligation to review the quotation carefully and to immediately advise Square D of any differing interpretation Purchaser has so any necessary change can be made. PRICE POLICY: All prices are subject to change without notice. In the event of a net price change and unless otherwise agreed to in writing, prices for orders scheduled for immediate release shall be those in effect at time of order entry. Prices for orders placed for future shipment without an agreed price and ship date will be billed at the pricing in effect as of the shipment date. All clerical errors are subject to correction. SUBSTITUTION: Square D may furnish suitable substitutes for material unobtainable because of priorities or regulations established by governmental authority or non-availability of materials from suppliers, provided such substitutions do not adversely affect the technical soundness of the equipment. Square D assumes no liability for deviation from published dimensions and descriptive information not essential to proper performance of the product. TAXES: Any manufacturer's tax, retailer's tax, occupation tax, use tax, sales tax, excise tax, (except federal excise tax on vehicles), duty, customs, inspecting or testing fee, or other tax, fee or charge of any nature whatsoever, imposed by any governmental authority or measured by any transaction between Square D and Purchaser, shall be paid by the Purchaser in addition to the prices quoted or invoiced, and such charges will appear as a separate line item on the invoice. In the event Square D will be required to pay any such tax, fee, or charge, Purchaser shall reimburse Square D or, in lieu of such payment, Purchaser shall supply Square D at the time the order is submitted with an exemption certificate or other document acceptable to the tax authority. Purchase Orders must state the existence and amount of any such tax, fee or charge for which Purchaser claims an exemption. TERMS OF PAYMENT: Acceptance of all Purchase Orders is subject to Purchaser meeting Square D credit standards. Terms are subject to change for failure to meet such standards. Terms are net thirty (30) days from date of invoice of each shipment, unless otherwise stated in Square D's quotation. For an authorized distributor or authorized reseller order, applicable terms of payment are stated in the quotation or applicable discount schedule. Square D reserves the right at any time to demand full or partial payment before proceeding with a contract of sale if, in its sole judgment, as a result of changes in the financial condition of the Purchaser the terms of payment originally specified are no longer justified. PAYMENTS: If delivery is delayed or deferred by the Purchaser beyond the scheduled date, payment shall be due in full when Square D is prepared to ship. The equipment may be stored at the risk and expense of the Purchaser. If the Purchaser defaults when any payment is due, then the whole contract price shall become due and payable upon demand, or Square D at its option, without prejudice to other lawful remedies, may defer delivery or cancel the contract for sale. If Purchaser becomes insolvent, or bankrupt or in the event any proceeding is brought against the Purchaser, voluntarily or involuntarily under the bankruptcy or any insolvency law, Square D may cancel any order outstanding at any time and recover its applicable cancellation charges from the Purchaser or the Purchaser's estate. DELIVERY: A: F.O.B. POINT OF SHIPMENT: When the Square D quotation is based on delivery F.O.B. point of shipment, freight prepaid and allowed for delivery within the continental United States, product is sold F.O.B. point of shipment, freight prepaid and allowed. A shipping and handling charge of twenty-five dollars ($25) will be added to all orders having a total net invoice price of less than one thousand dollars ($1,000). Delivery by Square D to the point of shipment constitutes delivery to the Purchaser; and title and all risk of loss or damage in transit shall pass to the Purchaser at time of delivery at the F.O.B. point. Square D is not responsible for breakage after having received "in good order" receipts from the carrier. Purchaser is responsible for pursuing any damage claims with the carrier. No allowance will be made in lieu of transportation if the Purchaser accepts shipment at factory, warehouse or freight station or otherwise supplies its own transportation. Freight prepaid is defined as: A) Shipments to destinations within the continental United States to the accessible common carrier point nearest the first destination. B) Shipments to U.S. destinations outside the continental United States shall be to the common carrier free delivery point in the United States nearest the original port of embarkation. All charges associated with F.A.S., C.I.F., or other charges such as pier transfer, lift, ocean freight, and marine or war insurance shall be paid by the Purchaser, unless otherwise specifically agreed in a specific Purchase Order. In no event will Square D be responsible for demurrage or detention charges. B: DELIVERY: F.O.B. DESTINATION: When the Square D quotation is based on delivery F.O.B. Destination, for shipments for delivery within the continental United States, Square D will retain title and all risk of loss or damage in transit to the common carrier free delivery point in the United States nearest the first destination for a price addition of 2% of the net price. If the Purchaser elects this option, Purchaser's obligations shall be as follows: A) Purchaser shall have the responsibility of inspecting the equipment for apparent loss or damage immediately upon its arrival at the free delivery point. B) In the event of apparent shipping loss or damage, Purchaser shall make written notation of the loss on the carrier's delivery receipt and, within 72 hours of delivery shall notify the Square D Customer Information Center. Purchaser shall not remove product from the point of examination and shall retain the shipping container and packing material. Purchaser shall request the carrier to make an inspection and send Square D a copy of the carrier's inspection report. C) In the event of concealed damage which occurred during transit and is discovered by the Purchaser after delivery, Purchaser shall report such damage immediately, but in no event later than 15 days after delivery, to the delivering carrier, and within 72 hours of discovery, shall notify the local Square D field office. If such notification is not made, Square D shall not be liable for loss or damage in transit. C: SHIPMENT AND ROUTING: Square D shall select the point of origin of shipment, the method of transportation and the routing of the shipment. Purchasers that request expedited or special modes of transportation or routing involving air, premium or any other non-standard Square D shipping shall be assessed additional charges for shipping, handling, freight and expediting. Any rebates, allowances, discounts or incentives received by Square D from its carriers shall be retained by Square D. All prices include domestic packaging only. When other than domestic packaging is required, contact your local Square D field office. Purchaser specified packaging and marking may be subject to additional charges. 9. SHORTAGES: Claims for shortages or errors must be submitted to Square D within 30 days after invoice date, and failure to give such notice shall constitute unqualified acceptance and a waiver of all such claims by the Purchaser. 10. INSTALLMENTS: Square D reserves the right to make shipments in installments, unless otherwise expressly stipulated in a specific Purchase Order; and all such installments when separately invoiced shall be paid for when due per invoice without regard to subsequent shipments. Delay in shipment of any installment shall not relieve Purchaser of its obligation to accept remaining shipments. 11. FORCE MAJEURE: Square D shall not be liable for any damages as a result of any delays due to any causes beyond Square D's control, including, without limitation, an act of God; act of Purchaser or Square D supplier; embargo or other governmental act; regulation or request; fire; accident; strike; slowdown; flood; fuel or energy shortage; sabotage; war; riot; delay in transportation and inability to obtain necessary labor, materials or manufacturing facilities from usual sources. In the event of any such delay, the date of delivery shall be extended for a period of time reasonably necessary to overcome the effect of such delay. 12. STANDARD WARRANTY: Square D warrants equipment manufactured by it and sold through authorized sales channels to be free from defects in materials and workmanship for eighteen (18) months from date of invoice by Square D or its authorized sales channel. If within such period any such equipment shall be proved to Square D's satisfaction to be non-conforming, such equipment shall be repaired or replaced at Square D's option. This warranty shall not apply (a) to equipment not manufactured by Square D, (b) to equipment that has been repaired or altered by other than Square D so as, in its judgment, to affect the same adversely, or (c) to equipment that has been subjected to negligence, accident, or damage by circumstances beyond Square D's control, or improper operation, maintenance or storage, or to other than normal use or service. With respect to equipment not manufactured by Square D, the warranty obligations of Square D shall in all respects conform and be limited to the warranty actually extended to Square D by its supplier. Non-conforming products must be returned at Square D's expense for evaluation unless this is waived in writing. Replacement products may be new or reconditioned. The foregoing warranties do not cover reimbursement for labor, transportation, removal, installation, temporary power, or any other expenses that may be incurred in connection with repair or replacement.
2.
3.
4.
5.
6.
7.
8.
17.
18.
19.
20.
21.
22. 23.
24.
25.
Numerics
1000 Vdc Photovoltaic Heavy Duty Disconnect Switch 3-23 14 inch wide panelboards 9-41 NQ Merchandise Panelboards 16 mm push buttons 19-12 19-22 22 mm Push Buttons 19-123 biometric switches 22 mm push buttons 19-8, 19-23 19-55, 19-57 19-62 2-box light curtain, XUSLT 25-6 16-19 16-20 2-Pole single phase full voltage starters 30 mm push buttons 19-9, 19-63 19-65, 19-69 19-75, 19-79 19-89 16-19 16-20 4-Pole, 2-Phase full voltage starters 19-106 70 mm XVB 8501 Type K and R relays 23-9 8M, 36M, 60M enclosure 5-20 25-2 9001 P palm buttons 9012G pressure switches 22-13 differential dual stage 22-13 industrial 22-11 machine tool 22-12 9013F commercial pressure switches 22-19 9013G commercial pressure switches 22-20 9016GAW vacuum switches 22-17 22-17 9016GVG vacuum switches 9036D float switches 22-21 9036FG float switch 22-22 22-21 9036G float switches 9038A, C mechanical alternators 22-24 9038D mechanical alternators 22-25
A
AB1 markers other blocks AB1AA insulation displacement blocks AB1DD, AB1ET three tier AB1ET two tier blocks AB1ETN two tier blocks AB1FU and AB1SF/SV fuseholders AB1RR spring clip blocks spring clip terminals AB1TP grounding blocks AB1VV and AB1TP miniature blocks AB1VV box lug blocks AC control relays AC drives Altivar 21 Altivar 31 Altivar 61 Altivar 71 documentation support training AC latching relays AC master relays 24-11 24-9 24-10 24-7 24-6 24-7 24-8 24-2 24-3 24-4 24-6 24-4 24-5 23-21 26-2 26-4 26-4 26-5 26-6 26-7 26-6 26-7 26-18 26-18 26-18 23-21 23-21
AC or DC operating coil AC timing relays Accessories accessories busbar C-Bus contactor contactors disconnect switch double throw safety switches F-Line float switches heavy duty safety switch I-Line panelboards insulation displacement style terminal blocks mechanical interlocks medical products meter centers meter sockets pressure switches machine tool proximity sensors QO and Homeline load center QO and QOB miniture circuit breaker QO load center QOU safety switches Sepam series solid neutral starters structured wiring system TeSys D-Line TeSys K-Line TeSys manual starters and protectors transformers transient suppression module Type K and SK Type KX
18-6 18-7 23-21 15-6 18-39 5-4 18-8 16-118, 18-14 8-23 3-16, 3-19 18-11 22-26 3-11 9-23 24-10 16-123 15-6 2-15 2-3
ALPHABETICAL LISTING
22-16 20-8 1-13 1-4 1-12 7-15 3-3 4-26 16-122 16-118, 18-34 5-31 18-11 18-27 18-36 14-10, 14-17 16-121 19-85 19-94 Whole House 6-7 XB6 19-20 accessories and modification kits, manual starters 16-7 accessories and modifications 16-9 manual starters and switches 12-8 accessories, Busway 13-6 accessories, Wall Duct AccuSine AHF 4-35 4-36 AccuSine AHF 4-35 4-36 dynamic VAR compensation Actuator Sensor Interface (AS-i) 27-7 27-8 adapter, I-Line to I-Line II 12-7 12-8 additions, Busway Advantys OTB automation products 27-5, 27-7 Advantys STB 27-5
Advantys TeleFast 2
prewired connection system alarm annunciator, medical products alternating industrial control relays Altistart 01, open soft starts Altistart 48, open soft starts Altivar 21 AC drives Altivar 31 AC drives Altivar 61 AC drives Altivar 71 AC drives analysis and consulting 24-22 15-6 23-20 26-15 26-17 26-4 26-4 26-5 26-6 26-7 26-6 26-7 4-20
Words in
i -1
3-10
B
backbox dual output voltage panels blank doors Model 6 MCC bodies, limit switches bolt-on remotely operated circuit breakers box lug blocks AB1VV bracket mounted disconnect devices brackets, transformers branch circuit power meter, branch current monitor, branch devices, meter centers branch feeder units, Model 6 MCC branch switches, QMB fusible branch units, meter centers buck and boost, transformers bus couplers, C-Bus busbar accessories busbar configuration code Busway accessories additions bussed transformer connection circuit breaker cubicle construction options elbows electrical data expansion fittings feeder finger protection to IP2X fused hangers high short circuit bracing 15-5 17-6 21-17 5-28 24-5 8-20 14-11
24-19 19-117 19-118 4-25 3-21 21-4 16-58 24-18 24-21 11-15 4-20 11-15 5-21
ALPHABETICAL LISTING
4-16 4-16
2-11, 2-13 17-6 9-34 2-8 14-4 5-15 18-39 12-3 12-1 12-8 12-8 12-7 12-7 12-16 12-6 12-8 12-7 12-6 12-7 12-7 12-6, 12-16 12-6 12-13 12-5 12-6, 12-11 12-6 12-7 12-14 12-6 12-3, 12-9 12-10 12-14 12-12 12-6 12-7 12-16 12-13 12-4 12-6 12-16 12-6 12-16 12-16 12-7 2-15 12-7 12-4
AS-i
Safety at Work 25-2 25-3, 25-5 AS-Interface safety AS-i 25-2 Safety at Work 25-3, 25-5 assemblies, terminal blocks 24-15 ATS01 higher horsepower, open soft starts 26-16 26-16 ATS01N1, open soft starts automatic-manual-stop control modules TeSys D-Line 18-10 automation power system 4-21 automation products 27-2 27-3 27-5 Advantys FTB Advantys OTB 27-5, 27-7 Advantys Telefast ABE7 27-5 Advantys Telefast ABE9 27-5 Concept 27-3 ConneXium ethernet products 27-6 ConneXium products 27-6 ConneXview industrial ethernet diagnostic software 27-6
Magelis
iPC M340
I-Line I-Line II
indoor drip resistant indoor tap boxes non-segregated bus outdoor construction plug-in units
Quantum
XBTF XBTGT XBTN/R PL7
Vijeo Designer
Vijeo Historian
27-4 27-2 27-2 27-5 27-2 27-4 27-5, 27-7 27-8 27-2 27-3 27-3 27-3 27-5, 27-7 27-3 27-3 27-3 27-6 27-2 27-2 27-4 27-4 27-4
Power-Zone
R-frame circuit breakers riser service heads space heaters special purpose plug-in units standard components standard straight lengths supports tee terminating accessories thermostats transformer taps transition section meter centers unfused reducer
Auxiliary contact kits for disconnect switches and circuit breakers auxiliary contacts manual and magnetic contactors and starters TeSys D-Line & F-Line auxiliary input unit auxillary gutter, QO load center
I-Line
i -2
Words in
C
C60N
Masterpact QO
7-16 7-17 24-21 24-20 8-16 25-8 25-8 25-2, 25-8 5-28 16-128 4-30 4-32 4-33 15-4 17-2 15-5 5-8 5-29 5-29 5-21 5-17 5-19 5-7 5-20 5-15 5-10 5-12 5-8 5-4 5-16 5-6 5-8 5-5 5-14 5-22 5-13 5-9 5-25 5-16 19-12
11-6
Multi 9 miniature circuit breakers cable ends AR1 and AT1 DZ5 and AZ5 cable operated disconnect switches cable pull switches emergency stop operation safety XY2 cables, Powerlink calculation of trip current rating thermal unit selection capacitor banks capacitor systems medium voltage catalog numbering example surgical facility panels catalog numbering system combination starters dual output voltage panels C-Bus Decorator Wall Plates Device Power Supply Device Router Devices Dimmers DLT Keypads Enclosures Input Sensors Multi Room Audio Neo Decorator Keypads Neo Keypads Relays RF Wireless Saturn Decorator Keypads Saturn Keypads Sensors Software Thermostats Touch Screens ceiling mount occupancy sensors changeover relay characteristics and complete devices XB6 circuit breaker ground fault circuit interrupter QWIK-GARD circuit breaker cubicle, Busway circuit breakers bolt-on remotely operated emergency lighting enclosures accessories dimensions enclosed walking beam mechanical interlock flexible cable mechanisms H- and J-frame I-Line panelboards I-Line switchboards I-Line panelboards I-Line switchboards
9-10 12-7 5-28 5-28 7-56 7-58 7-58 7-57 8-21 8-22 9-26 9-26 9-24 9-25 9-24 9-25
EPD 7-11 HM, high magnetic trip 7-11 K, key operated 7-11 SWN 7-11 QO enclosures 1-24 QO plug-on 1-2 sub-station 11-18 Tenant 2-6 Type FVR Powersub 11-18 UL Listed 500 Vdc 7-34 circuit meter 4-16 circuit monitor, PowerLogic 4-10 4-11 circuit protectors 24-17 thermal-magnetic closed tank float switches 9037E 22-22 9037H 22-23 9038C mechanical alternators with bushing 22-24 9038D mechanical alternators 22-25 coaxial video surge suppressor 6-7 coil replacement, definite purpose contactors 16-77 coil voltage codes 18-3, 18-5 18-6 combination 16-66 lighting contactors combination service entrance devices 1-22 accessories all-in-ones, rainproof 1-20 circuit breakers 1-22 dimensions 1-23 hubs 1-22 meter mains, rainproof 1-19 combination starters catalog numbering system 17-2 Compac 6 fusible switch disconnects 17-5 Model 6 MCC 17-3 NEMA rated 16-30 accessories 16-40 application data 16-39 control transformers 16-40 dimensions 16-41 fusible disconnect switch type 16-30 disconnect switch type with class R fuse clips 16-32 interlocks 16-40 MCP circuit breaker 16-34 16-35 non-fusible disconnect switch type 16-31 thermal magnetic circuit breaker 16-37 16-38 NEMA rated oversized enclosure MCP circuit breaker 16-36 two speed 16-58 commercial pressure switches 22-19 22-20 communications, wiring, busbar system 18-38
Compac 6
combination starters motor circuit protector Disconnects Model 6 MCC compact general duty limit switches compact height switches MiniBreak compact pilot lights complete devices XB4 XB5 complete switches, limit switches 17-5 17-5 17-5 21-20 11-7 19-10 19-23 19-42 21-14
Words in
i -3
ALPHABETICAL LISTING
components, Wall Duct 13-6 16-122 compression lugs Concept automation products 27-3 configuration code, busbar 12-3 21-17 connection components, limit switches ConneXium products, automation products 27-6 ConneXview Industrial Ethernet diagnostic software 27-6 12-16 construction options, Busway consulting, analysis 4-20 contact assemblies, limit switches 21-17 19-114 contact blocks XAC pendant station contact units for melting alloy type overload relays 16-117 replacement parts kits contactors 18-6 16-118, 18-8, 18-14 accessories control circuit fuse holder 16-121 cover-mounted control units 16-118 definite purpose 16-76, 16-88 power pole adders 16-121 replacement parts kits 16-116 reversing mini-contactors 18-25 TeSys 18-38 TeSys D- and F-Line AC coils repair parts 18-18 TeSys D-Line 3- and 4-pole reversing 18-6 TeSys D-Line AC coils repair parts 18-17 TeSys D-Line DC coils repair parts 18-19 TeSys D-Line non-reversing 18-2, 18-4 TeSys F-Line 18-12 TeSys F-Line 3-pole reversing 18-7 TeSys F-Line DC coils repair parts 18-20 TeSys F-Line non-reversing 18-3, 18-5 TeSys K-Line 18-27 4-pole 18-26 non-reversing contactors 18-24 reversing contactors 18-25 contactors and starters 16-12 NEMA, magnetic AC catalog numbering system Control and Measurement Relays 23-44 control and signaling units biometric switches 19-124 control circuit fuse holder contactors 16-121 starters 16-121 control stations enclosures 19-66 19-68, 19-76 19-78, 19-96 19-100 controlled panels 15-6 supervisory module X-ray indicator 15-6 15-6 controlled panels receptacle module 14-3 copper wound transformers corrosion resistant 19-74, 19-80 multifunction operators non-illuminated operators 19-73 pilot lights 19-79 23-36 counters, Zelio 3-13 cover viewing window for safety switches cover-mounted control units contactors 16-118 starters 16-118 Crouse-Hinds Arktite receptacle safety switches 3-10
3-10 4-15 9-40 23-30 21-5 9-40 14-20 11-11 24-15 20-8
ALPHABETICAL LISTING
D
DALI gateway data hubs structured wiring system DC control relays DC latching relays DC timing relays DC utility relays decorator face plates Decorator Saturn keypads decorator style cover plates, Neo definite purpose contactors reversing hoist device power supply
5-18 5-31 23-22 23-22 23-22 23-22 5-8 5-8 5-8 16-76 16-88 16-89
Powerlink 5-29 device routers, Powerlink 5-29 differential pressure switches 22-13 digital clock, medical products 15-6 dimensions Altistart U01 soft starters 18-51 definite purpose contactors 16-78, 16-80 disconnect switches 8-9, 8-14 double throw safety switches 3-8 3-9, 3-18, 3-20, 3-22 duplex motor controllers 16-87 enclosures 16-105, 16-108 lighting contactors 16-72 16-75 meter centers 2-16 meter sockets 2-4 pressure switches 9013G 22-15 XML international 22-10 XMLG electronic 22-5 reversing drum switches 16-10 safety switches 3-3, 3-14 TeSys D-Line combination and non-combination starters 18-48 contactors, AC coil 18-40 contactors, DC coil 18-41 overload relays 18-45 reversing contactors 18-44 thermal overload relays 18-46 TeSys F-Line overload relays 18-47 TeSys F-Line contactors 18-42
i -4
Words in
TeSys GV7
manual starters and protectors TeSys K-Line contactors TeSys Manual starters and protectors TeSys U-Line motor starters soft starters 18-54 18-49 18-52 18-50 18-51
Well-Guard
pump panels 16-84 dimensions and shipping weights 7-54 miniature and molded case circuit breakers molded case circuit breakers 7-55 3-23 dimensions, Disconnect Switches 5-17 dimmer unit, four channel DIN rail mounted Multi 9 surge protective devices 6-5 disconnect devices, bracket mounted 8-20 disconnect switch 8-23 accessories flange mounted 8-23 8-24 variable depth 8-23 8-24 disconnect switches cable operated 8-16 dimensions 8-9, 8-14 door mounted 8-12 door-mounted operating mechanisms 8-13 flange mounted 8-16 8-17 GS1 fusible 8-6, 8-10 IEC style 8-6, 8-9 LK3 non-fusible 8-6, 8-10 NEMA style 8-12 type T 8-20 variable depth 8-16 8-17 14-18 disconnects, transformers DLT keypads 5-7 documentation, AC drives 26-18 door closing mechanisms 8-25 8-26 Types M5, M6, M1, and M8 door mounted disconnect switches 8-12 operating mechanisms 8-14 dimensions 8-15 double throw safety switches 3-16 3-17 drive isolation transformers 14-7 14-8 14-9 dry type transformers dual output voltage panels 15-5 dual stage pressure switches 22-13 duplex 16-85 16-86 motor controllers 15-3 duplex panels, medical products 24-20 DZ5 and AZ5 cable ends
electrical components Type K, SK and KX XB4 XB5 XB6 electrical data I-Line II Busway electrical data, Busway electrical interlock kits safety switches electrical ratings pressure switches, 9012 and 9016 electronic pressure switches XMLF electronic timers IEC style 17.9 mm wide 22.5 mm wide plug-in timers electronic timers and interface modules TeSys D-Line electronic trip units Micrologic emergency lighting circuit breakers emergency stop operation cable pull switches emergency stop operators emergency stop XB4 operators Enclosed enclosed GFCI circuit breakers molded case switches enclosed combination starters enclosure modifications
23-24 23-25 23-28 18-10 7-43 5-28 25-8 19-48 19-28 7-57 1-24 1-24 18-23 18-23 18-23
Insta-Kits
overload relays
TeSys D-Line
circuit breaker 18-22 fusible disconnect switch 18-22 enclosed drives EFlex AC Drives 26-12 SFlex AC Drives 26-14 enclosed starters TeSys D-Line metal enclosures 18-21 enclosure 8M, 12M, 24M, 36MS, 36M, 60M 5-20 enclosure dimensions PFC capacitor banks 4-33 enclosure modifications 18-23 enclosed combination starters enclosures circuit breaker 7-56 control stations 19-66 19-68, 19-76 19-78, 19-96 19-99 dimensions 16-105, 16-108 flush mounting selection table 16-103 NEMA 1 selection table 16-103 NEMA 12/3R outdoor applications 16-104 NEMA type 1 and flush mounting 16-103 NEMA type 3R, 4, 4X, and 12 16-102 NEMA types 1, 4, and oversize 16-104 transformers 14-10, 14-18 XAC 19-114 enclosurescontrol stations 19-100 end clamps 24-12 4-15 energy meters energy profiler online service 4-18
E
EE harmonic mitigating transformers EE medium voltage, dry type transformers EE NL transformers EFlex AC Drives, enclosed drives elbows, Busway 14-7 14-9 14-6 26-12 12-6
Words in
i -5
ALPHABETICAL LISTING
engineering service, PowerLogic equipment grounding kits for safety switches Ethernet-Modbus/TCP networks expansion fittings, Busway export model transformers external reset mechanisms externally mounted surge protective devices extra capacity single phase starters full voltage starters
4-20 4-21 3-12 4-19 12-7 14-4 16-101 6-2 16-21 2-16 2-8 2-15 2-14
sump applications
Sumptrol
EZ Meter-Pak
meter center dimensions meter centers meter centers and accessories EZM main devices meter centers
F
face plates 5-8 decorator factory assembled enclosures, PowerLogic 4-22 factory assembled panelboards 9-18 factory modifications 21-26 limit switches pressure switches machine tool 22-16 factory modifications (forms) full voltage contactors & starters 16-109 full voltage contactors & starters and solid state overload relays 16-111 factory-installed accessories QO and QOB miniature circuit breakers 7-12 Features, Merchandised Units 17-2 feeder, Busway 12-6 F-frame 7-49 thermal-magnetic circuit breakers 12-7 finger protection to IP2X, Busway Fingersafe 7-15, 14-4, 14-17, 19-81, 24-13 19-81 Fingersafe contact blocks Fingersafe cover for 9001KM 19-89 fittings, Wall Duct 13-6 flange mounted 8-16 8-17 disconnect switches 8-21 8-22 flexible cable mechanisms, circuit breakers F-Line 18-11 accessories overload relay accessories 18-16 float switches 22-1 22-22 9036FG 9037E 22-22 9037H 22-23 9038A, C mechanical alternators 22-24 9038D mechanical alternators 22-25 accessories 22-26 closed tank 22-23 22-24 9037E 22-22 9038D mechanical alternators 22-25 open tank 22-21 22-22, 22-24 renewal parts 22-26
float switches, 9036D and 9036G flush mounting surge protective device food, beverage proximity sensors foot switches four channel dimmer unit fractional horsepower 16-2 manual starters Frequency Control Relays 23-34 full voltage contactors NEMA rated 3-pole polyphase 16-13 general information 16-13 solid state overload relay protection, Motor Logic 16-17 full voltage contactors & starters and solid state overload relays factory modifications (forms) 16-111 full voltage contactors and starters 16-109 factory modifications (forms) NEMA rated application data for selection 16-22 dimensions 16-23 16-26 full voltage reversing contactors and starters NEMA Rated solid state overload relay protection Motor Logic 16-45 NEMA rated 16-43 dimensions 16-47 16-48 full voltage reversing vacuum contactors NEMA rated approximate dimensions 16-49 16-17 16-18 full voltage starters 16-19 16-20 2-Pole single phase 4-Pole, 2-Phase 16-19 16-20 extra capacity single phase starters 16-21 NEMA rated 16-17 16-18 2-pole single phase 16-21 Types SBSD with auxiliary load terminals 16-21 full voltage vacuum contactors general information 16-27 16-28 16-29 full voltage vacuum starters 16-124 fuse block, replacement parts kits 3-11 fuse kits safety switches, class R fuse puller kits, safety switches 3-3 fuse selection tables 11-14 boric acid fuses, HVL DIN/E HVL 11-14 fused HVL/cc load interrupter switch 11-16 fused, Busway 12-7 fuseholders AB1FU and AB1SF/SV 24-8 application information 24-19 LS1 18-36 panel mounting 24-19 Type FB 24-19 Fuselogic 11-8, 11-11 3-16 fusible and non-fusible safety switches
22-21 22-22 22-21 22-22 22-21 6-2 20-8 19-119 19-120 5-17
ALPHABETICAL LISTING
G
G3 systems, Powerlink gateway, DALI Gen 3 products, lighting control systems 5-28 5-18 5-27
i -6
Words in
general duty safety switches general information full voltage vacuum contactors general purpose dry type transformers general purpose plug-in timers general thermal unit selection GFI, QO circuit breakers GFP ground fault protectors, Multi 9 ground-fault protection GC DSP display GC-200 ground-fault relay system sensors ground-fault relay system GC-200
HVL switchgear quick ship program 3-2 16-27 16-28 14-2 23-28 16-125 7-11 7-18 7-46 7-46 7-46 7-46 7-46 7-47 24-6 8-10 8-6 25-6
HVL/cc
ALPHABETICAL LISTING
medium voltage metal-enclosed metal-enclosed load interrupter switchgear switchgear switchgear quick ship program hybrid VAR compensator (HVC)
I
IEC IEC style disconnect switches industrial control relays terminal blocks IEC terminal blocks I-Line series ratings 24-10 8-6, 8-9 23-20, 23-43 24-2 24-9, 24-11 24-12 24-10 9-3
Vigirex
grounding blocks AB1TP GS1 fusible disconnect switches GS1/GS2 fusible disconnect switches guarding point, operation around machinery
I-Line
factory assembled panelboards 9-31 molded case circuit breakers 11-17 terminal data 9-39, 9-41 I-Line distribution 11-16 I-Line distribution bus 11-4 I-Line distribution section 11-5 I-Line II Busway 12-8 electrical data I-Line II, Busway 12-5 12-6, 12-11 I-Line panelboards 9-20 9-21 I-Line panelboards 9-33 pricing I-Line to I-Line II adapter 12-7 I-Line, Busway 12-13 illuminated beacons 19-103 19-112, 19-123 19-124 indicating banks illuminated operators 19-53 indicating banks 19-103 19-112 illuminated beacons 12-6 indoor drip resistant, Busway 2-8, 2-10, 2-12 indoor meter centers indoor tap boxes, Busway 12-7 indoor, 1 main circuit breaker, QO load center 1-6 1-5 indoor, main lug, QO load center industrial 21-22 limit switches snap switches 21-6 industrial control transformers 14-14 Industrial Energy Efficiency 4-21 22-11 industrial pressure switches input units, C-Bus 5-15 inserts legend 19-38 legends 19-59 18-23 INSTA-KITS 18-23 Insta-Kits enclosed combination starters instrument transformers 14-20 insulated case circuit breakers selection information 7-9 18-12 insulated terminal blocks overload relays insulation displacement blocks, AB1AA 24-10 integral horsepower 16-6 16-7 manual starters i -7
H
hangers, Busway Hard Bus TVSS hard-wired secondary surge arrester HCR-U heavy duty limit switches specialty operators heavy duty safety switches HID QO circuit breaker high ampere QOU circuit breakers High Density Meter Enclosures high harmonic loads, transformers high short circuit bracing, Busway HMIhuman machine interface holders legend 12-6, 12-16 9-12, 9-19 6-6 11-17 21-22 19-71 3-4 7-11 7-14 4-11 14-6 12-6 16-94 19-37, 19-58
Homeline
HOM-AFI circuit breaker 1-14 HOM-EPD circuit breaker 1-14 HOM-GFI circuit breaker 1-14 HOM-HM circuit breaker 1-14 HOMT, quad tandem circuit breaker 1-14 Homeline load center 1-16 convertable field-installable kits indoor, main circuit breaker 1-15 indoor, main lug 1-15 plug-on circuit breakers 1-14 rainproof main circuit breakers 1-16 rainproof, main lug 1-16 horizontal ganged meter sockets 2-3 horizontal ganged meter sockets 2-3 horsepower and voltage thermal unit selection 16-129 Hubbellock receptacle safety switches 3-10 11-11 HVL medium voltage metal-enclosed HVL metal-enclosed load interrupter switchgear 11-11 HVL switches, Power-Dry, Power-Cast, transformer 11-12 connections
Words in
integral switch surge protective device integrated equipment sample lineups Integrated Power and Control Solutions IPaCS equipment Integrated Power Center IPC layout lead time pricing shipping Integrated Power Center 2
6-2 10-6 10-2 10-3 10-2 10-3 10-3 10-3 10-3 10-3 10-2, 10-4 10-5 10-4 10-4
L
LA9D09980 LA9D09981 LA9F980 layout Integrated Power Center Integrated Power Center 2 lead time Integrated Power Center Integrated Power Center 2 legends holders inserts legends, inserts lever arms limit switches L-frame electronic trip circuit breakers thermal-magnetic circuit breakers life safety, medical products light curtains XUSL light level sensor lighting contactor multipole lighting lighting contactors combination dimensions mechanically held ASCO Type 920 modifications lighting contactors panelboards limit switches application data bodies common heads and levers miniature and compact bodies compact general duty complete switches connection components contact assemblies factory modifications heavy duty industrial industrial snap lever arms mill and foundry miniature oiltight 18-12 18-12 18-12 10-3 10-4 10-3 10-4 19-37, 19-58 19-38 19-59 21-9, 21-24
ALPHABETICAL LISTING
IPC2
layout lead time pricing
10-4 shipping 10-4 23-38 interface modules 23-42 electromechanical solid state 23-41 TeSys D-Line 18-10 interlock switches, safety 25-7 internal barrier kits for safety switches 3-11 internally mounted surge protective devices 6-4 22-8 22-9 international pressure switches, XML ION EEM enterprise energy management software 4-6 ION enterprise operations software, PowerLogic 4-4 4-4 ION enterprise software ordering information ION power and energy meter, PowerLogic 4-7 4-8 IPaCS equipment 10-2 IPaCS equipment 10-2 Integrated Power and Control Solutions 26-17 iPAQ PPC 10-2 10-3 IPC Integrated Power Center
7-52 7-35, 7-51 15-2 25-6 25-2, 25-6 5-14 16-64 16-64 16-65 16-66 16-72 16-75 9-37 16-69 16-71 16-68 21-4 21-17 21-16 21-20 21-14 21-17 21-17 21-26 21-22 21-23, 21-27 21-22 21-6 21-9, 21-24 21-31 21-32, 21-34 21-8 21-9 21-31 21-32 21-14 25-8 21-8 21-31 21-34 21-8 21-6 21-28 21-29 21-30 21-27 21-20 15-1
2009 Schneider Electric All Rights Reserved
IPC2
Integrated Power Center 2 transformer combo 10-2, 10-4 10-5 10-2 15-1 15-1 16-122 15-2
Iso-Gard
line isolation monitor standard equipment isolated alarm contacts melting alloy overload relays isolated power panels medical products
J
JORNADA 26-17
Osiswitch
K
K- and Q4-frame thermal-magnetic circuit breakers 7-50 K2 custom and K30K150 19-121 19-122 power switching 3-13 key interlock systems for safety switches keypads 5-4 5-8 C-Bus Decorator Saturn 5-8 DLT 5-7 Neo style 5-4 Saturn 5-5
safety selection severe duty specifications without enclosures XCKJ bodies and options operating heads operating heads, replacement parts, and levers XCKJ precision switches with direct acting contacts XCKL complete switches line isolation monitor
Iso-Gard
i -8
Words in
liquid level relays 23-34 LK3 non-fusible 8-6, 8-10 disconnect switches load center value pack, QO and Homeline load center 1-11 load interrupter switch 11-16 fused HVL/cc 11-11 load interrupter switchgear 3-13 lock-on provisions for safety switches low ampere QOU miniature circuit breakers 7-14 low voltage ride through module TeSys D-Line 18-10 low voltage switchgear Power-Zone 11-6 LS1 fuseholders 18-36 LTMCU compact display 16-94 LTME expansion module 16-94 16-94 LTMR controller lugs 16-122 compression safety switches 3-3, 3-13 3-14 transformers 14-11
M
machine safeguarding products Preventa machine tool pressure switches Magelis Display Magelis iPC automation products Magelis M340 automation products 25-2 22-12, 22-16 16-94 27-4 27-2 27-2 27-5 27-2 27-4 27-5 27-2 27-3 27-3 27-3 27-5, 27-7 27-3 27-4 27-4 27-3 27-3 27-3 7-30 7-30 16-34 16-83 16-114
Magelis Momentum
automation products
Magelis Premium
automation products
magnetic starters reversing two-speed two-speed main circuit breaker Speed-D switchboards without overload trip panelboards main circuit breaker kits, QO load center main devices, meter centers manual and magnetic contactors and starters auxiliary contacts manual starters accessories and modification kits fractional horsepower melting alloy type thermal overload relay general purpose enclosure (flush mount) dimensions general purpose enclosure (surface mount) dimensions integral horsepower dimensions open type dimensions reversing and two speed watertight die cast zinc enclosure dimensions manual starters and switches accessories and modifications manual switches general purpose enclosure (flush mount) dimensions general purpose enclosure (surface mount) dimensions non-reversing open type dimensions reversing two speed watertight die cast zinc enclosure dimensions markers, AB1 terminal blocks
16-61 16-59 9-40 9-37 1-5 2-12 16-119 16-2 16-7 16-2 16-2 16-4 16-4 16-6 16-7 16-8 16-4 16-7 16-4 16-9
ALPHABETICAL LISTING
16-4 16-4 16-3 16-4 16-3 16-3 16-4 24-11 11-15 11-15
Masterclad
medium voltage Metalclad switchgear
Magelis products
automation products
Magelis Quantum
automation products
Magelis XBTF
automation products
Magelis XBTGT
automation products
Magelis XBTN/R
automation products Magelis Compact iPC Magelis Smart Magelis XBTGK Magelis XBTGTW Magelis XBTRT Mag-Gard circuit breakers
Mag-Gard
motor circuit protectors (MCP) Mag-Gard combo starter Mag-Gard pump panel magnetic coils
circuit breakers 11-6 NT/NW circuit breakers 7-45 NW and NT circuit breakers 11-6 universal power circuit breakers 7-45 MasterPact NT circuit breaker 7-45, 11-3, 11-6 MasterPact NW circuit breaker 7-43, 7-45, 11-3, 11-6 MCP selection GJ-, LA-, and MA-frame 7-31 mechanical alternators 22-24 22-25 mechanical interlock accessories 16-123 18-8 mechanical latch TeSys D-Line & F-Line mechanisms 8-25 door closing medical products 15-1 15-6 accessories alarm annunciator 15-6 digital clock 15-6 duplex panels 15-3 isolated power panels 15-2 life safety 15-2 remote alarm indicators 15-6 replacement parts 15-6
Words in
i -9
surgical facility panels timers medium voltage capacitor systems medium voltage metal-enclosed HVL
15-4 15-6 4-33 11-11 11-8, 11-10 14-8 16-117 16-122 10-6 11-5 11-5 17-2 11-15
24-4 7-17 7-17 7-10 7-12, 7-14 7-14 7-2 21-8 21-9 11-7 11-7 8-3 17-6 17-6 17-6 17-3 17-4 17-3 17-5 17-2 17-2 16-69 16-71 6-2 10-3 10-2 10-3 7-52 7-55 1-11 7-30 17-1 17-2 17-2 17-2 17-2
ALPHABETICAL LISTING
HVL/cc
Medium Voltage transformers melting alloy overload relay jumper strap kits melting alloy overload relays isolated alarm contacts merchandise configurations transformer combo Merchandised merchandised service selection merchandised units Model 6 MCC Metalclad switchgear meter centers accessories branch device dimensions branch devices branch devices, NEMA 3R construction branch devices,NEMA 3R construction branch units dimensions
MiniBreak
compact height switches
EZ Meter-Pak
EZM main Busway tap EZM main devices indoor indoor Busway mains main devices
MP Meter-Pak
NEMA 3R construction rainproof ring and ringless devices selection information Tenant circuit breaker accessories Tenant circuit breakers meter centers, Busway transition section meter comparison chart meter door selection meter mains test block bypass, EUSERC meter sockets accessories dimensions horizontal ganged ring and ringless type, individual meter sockets test block bypass sockets metering
2-15 2-16 2-11, 2-13 2-13 2-14 2-11 2-8 2-16 2-8 2-14 2-14 2-8, 2-10, 2-12 2-14 2-12 2-5 2-8, 2-10 2-8, 2-10, 2-12 2-5 2-9 2-6 2-6 2-15 4-9 11-5 2-3 2-3 2-4 2-3 2-2 2-3 4-7
Compac 6
merchandised units motor control centers modifications lighting contactors modular external SPD surge protective device modular panelboard system MPS molded case circuit breakers dimensions and shipping weights Mono-Flat Front riser panels motor circuit protectors (MCP)
Mag-Gard
motor control centers Model 6 structure features unit features Model 6 MCC
Transparent Ready
motor controllers duplex motor disconnect switches
Micrologic
electronic trip units 7-43 accessories 7-44 adjustable rating plugs selection 7-44 trip system 7-52 trip unit accessories 7-53 trip units 11-6 21-31 21-32, 21-34 mill and foundry limit switches Mini Power-Zone transformers 14-12 miniature plug-in relays 23-11 miniature and molded case circuit breakers dimensions and shipping weights 7-54
16-85 16-86 8-2 Mini-Vario 8-3 Mini-Vario assembled and enclosed Switches 8-2 Vario assembled and enclosed switches 8-2 Vario switches 8-3 Motor Logic and Motor Logic Plus solid state overload relay accessories 16-120 16-91 Motor Logic Plus overload relay Motor Logic Plus solid state overload relay dimensions 16101 7-37 motor operators motor protection selection tables 7-32 motor protectors 18-38 spring terminals motor starters TeSys U-Line accessories 18-30 18-32 auxiliary contact blocks 18-30 18-32 function modules 18-29
i -10
Words in
Motorpact
medium voltage motor controllers vacuum substations mounting bases 11-18 11-18 7-13 7-13 24-12 2-5 2-7 2-7 10-2 10-3 7-20
Multi 9 QO
mounting track
MP Meter-Pak
meter centers meter centers dimensions meter centers knockouts MPS, modular panelboard system
Multi 9
C60 accessories C60N miniature circuit breakers DC telecommunication applications supplementary protectors GFP ground fault protectors miniature circuit breakers mounting bases NC100 miniature circuit breakers ground fault protectors
7-17 7-19 7-18 7-17 7-13 7-18 6-5 4-14 5-31 16-64 16-58 14-14 11-18
O
occupancy sensors auxiliary relay ceiling mount fixture mount power pack wall mount occupancy sensors, C-Bus oiltight limit switches open soft starts Altistart 01 Altistart 48 ATS01 higher horsepower ATS01N1 open tank float switches 9036D, G 9036FG 9038A mechanical alternators operating mechanisms door mounted operation around machinery, guarding point operators accessories, XAC standard duty emergency stop heavy duty specialty illuminated non-illuminated XB4 Specialty XB5 specialty optional equipment, surgical facility panels options Altivar 21 Altivar 31 Altivar 61 Altivar 71 options, surge protective devices Osisense photoelectric sensors 5-24 5-26 5-25 5-25 5-26 5-25 5-25 5-14 21-31 21-32 26-15 26-17 26-16 26-16 22-21 22-22 22-24 8-14 25-6 19-116 19-48 19-71 19-53 19-45 19-30 19-50 15-4 26-5 26-5 26-9 26-9 6-3 20-2
N
NEMA 3R construction meter centers NEMA 7 and 9 safety switches NEMA rated combination starters full voltage reversing contactors full voltage starters full voltage vacuum contactors NEMA style disconnect switches terminal blocks Type X industrial control relays NEMA type 1 and flush mounting enclosures NEMA type 3R, 4, 4X, and 12 enclosures NEMA Type 4, 4X, 5, 7, 9 and 12 safety switches NEMA types 1, 4, and oversize enclosures Neo decorator style cover plates Neo style decorator keypads network accessories, Powerlink network bridge, C-Bus network components, Web-enabled neutral assemblies for safety switches 2-8, 2-10 3-7 16-30 16-43 16-17 16-27 8-12 24-13, 24-15 23-21 16-103 16-102 3-15 16-104 5-8 5-8 5-29 5-18 4-19 3-12
Words in
i -11
ALPHABETICAL LISTING
power base accessories power bases reversing blocks motor starters PowerSuite software Motorpact
18-31 18-32 16-11, 18-28 18-32 18-30 18-32 18-31 18-32 11-18
NF panelboards 9-18 9-19 9-13 20" wide enclosures accessories 9-14 terminal data 9-38 Night-Master combination lighting contactors 16-67 NLP series transformers 14-6 non-automatic miniature switches 7-11 1-3 non-automatic miniature switches, QO, plug-on non-contact safety, interlock switches, XCSDM 25-2 non-illuminated operators 19-45 non-nodular external SPD 6-2 surge protective devices 16-3 non-reversing manual switches 12-14 non-segregated bus, Busway non-ventilated transformers 14-5 NQ 9-38 9-6 9-9 20" wide enclosures panelboards terminal data 9-38 9-6, 9-11 9-12 NQ panelboards 11-4 NQOD distribution bus nurses station indicator 15-6
Osisense proximity sensors Osisense RFID, radio frequency identification Osiswitch limit switches
other blocks, AB1 other products other products, safety systems outdoor construction, Busway overload relays enclosed combination starters insulated terminal blocks jumper strap kits, melting alloy TeSys D-Line accessories
ALPHABETICAL LISTING
20-5 20-6 20-9, 20-12 21-14 24-9 23-37 25-2 12-6 18-2 18-5 18-23 18-12 16-117 18-16
P
palm buttons, 9001 P panel mounting fuseholders panelboards factory assembled 25-2 24-19
9-18 9-20 9-21 NF circuit breakers 9-15 NF factory assembled 9-18 9-19 NQ 9-6, 9-11 9-12 circuit breakers 9-11 feed-thru lugs 9-12 sub-feed lugs 9-12 NQ/NF Merchandised Single Row (Column Width) Panelboards 9-16 9-17 NQOB applications data 9-16 9-17 QMB 9-20, 9-36 shunt trip circuit breakers 9-37 11-16 panelboards I-Line distribution 16-68 panelboards lighting contactors panels, dual output voltage 15-5 PC Interface (PCI), C-Bus 5-18 19-114 19-118 Pendant stations 19-117 19-118 ordering information, application PFC capacitor banks anti-resonant and filtering automatic, main lugs and circuit breaker 4-31 automatic, main lugs or main circuit breakers 4-30 enclosure dimensions 4-33 transient free reactive compensation 4-32 pharmaceutical / cylindrical stainless steel 20-8 phase failure relays 23-31, 23-35 23-37 Phaseo DC power suppies photoelectric sensors 20-2 Osisense 20-2 XUB tubular 20-2 XUM miniature, XUK and XUX compact 20-4 3-23 Photovoltaic Heavy Duty Disconnect Switch, 1000 Vdc 19-10 19-11 pilot lights 19-10 compact corrosion resistant 19-79 Type K Heavy Duty 19-70 XB4 19-31 XB5 19-51 PL7 automation products 27-3 PLCs XPSMF 25-4 Plug-In Relays Square D 23-9 12-3, 12-9 12-10 plug-in units, Busway pneumatic timers 23-29
I-Line
Pocket PC connection kit. Power power distribution blocks application data power meters energy meters power meters PowerLogic power pole adders contactors starters power relays enclosure power switching K2 custom and K30K150 power system automation Powerbus 225, Busway Powerlink breakers cables control bus controller misc. hardware power supply remote source controller
26-17 11-2 24-18 4-7 4-8 4-10 16-121 16-121 23-14 23-14 19-121 19-122 4-21 12-2 5-28 5-28 5-28 5-28 5-28 5-28 5-28 4-2 4-10 4-11 11-1 4-13 4-20 4-21 4-19 4-22 4-11 4-21 4-4 4-6 4-7 4-14 4-10 4-5 4-5 4-24 4-21 4-13 4-21
PowerLogic
circuit monitor circuit monitors E5600 socket meter engineering services Ethernet Gateways factory assembled enclosures high density meter enclosures industrial energy efficiency ION Enterprise software ION power and energy meters Multi circuit energy meter power meter powerview software scada software Sepam series system integration Tenant metering software total energy control
PowerPact
circuit breaker accessories 7-36 7-37 compression lugs 7-40 G-, H-, J-, Q-, D-, M-, P-, and R-frame circuit breakers locks 7-38 installation accessories 7-38 mechanical lugs 7-39 plug-in and drawout mountings 7-42 power distribution connectors (PDC) 7-40 rear connections 7-38 terminal nuts, terminal pads, terminal shields 7-41 circuit breakers D- and M-frame 7-25 G- and Q-frame 7-24 H- and J-frame 7-22 molded case 7-21 P-frame 7-26 R-frame 7-27 H- and J-frame electronic motor circuit protectors 7-28 molded case circuit breakers 11-16 Powerpact P circuit breakers 11-17 Powerpact R circuit breakers 11-17
2009 Schneider Electric All Rights Reserved
i -12
Words in
Power-Style
commercial multi-metering switchboards 11-3 11-2 11-3 11-3 11-2 11-18 11-18 18-31 18-32 26-17 4-5 11-6 11-17 11-16 11-16 12-14 22-1 22-16 22-19 22-20 22-13 22-15 22-10 22-7 22-5 22-13 22-16 22-11 22-12 22-20 22-26 22-8 22-9 22-6 22-7 22-4 22-4 25-2 25-4 25-4 25-5 24-22 10-3 9-18 9-5 9-5 5-17 27-3 20-5 20-8 20-8 20-8 20-7 20-5
QED-2
switchboard
20-6 23-33
ALPHABETICAL LISTING
QED-6
commercial multi-metering switchboard
Well-Guard
pump seal failure relays
Pumptrol
compressor pressure switches 22-18 pressure switches 22-20 water pump pressure switches 22-19 push buttons 16 mm 19-12 19-22 push buttons 22 mm 19-8, 19-23 19-55, 19-57 19-62 push buttons 30 mm 19-9, 19-63 19-65, 19-69 19-75, 19-79 19-89
QED-S
switchboard
Powersub
vacuum substation circuit breaker Powersub Vacuum Substation Circuit Breakers PowerSuite software motor starters PowerSuite upgrade CD Powerview software, PowerLogic
Power-Zone
low voltage switchgear Model III distribution section package unit substations unit substations Power-Zone, Busway pressure switches accessories machine tool commercial differential dimensions 9013G XML international XMLF XMLG electronic dual stage factory modifications machine tool industrial machine tool
Q
QED-2 Power-Style
switchboards QED-6 rear-connected switchboards QED-6 switchboards 11-2 11-3 11-3 11-2 1-24 9-35 9-39, 9-41 9-34 9-34 9-34 9-20, 9-36 7-11 15-2
QED-S Power-Style
switchboards Q-frame circuit breaker enclosures QMB fusible panelboards terminal data QMB fusible branch switches QMB/QMJ panelboards QMB/QMJ switchboards QMB panelboards QO circuit breakers
QO
circuit breakers accessories 7-12 arc fault 7-11 GFI 7-11 HID 7-11 HM, high magnetic trip 7-11 K, key operated 7-11 miniature 7-10 arc-fault circuit breaker 7-11 SWN 7-11 EPD circuit breakers 7-11 GFI 7-11 HID 7-11 mounting bases 7-13 plug-on non-automatic miniature switches 1-3 QO and Homeline load center 1-13 accessories indoor load centers dimensions 1-17 knockouts 1-17 rainproof dimensions 1-18 rainproof knockouts 1-18 rainproof, bolt-on hubs 1-18 load center value pack 1-11 riser panels 1-11 voltage testers 1-13 QO and Homeline load center panelboards-style covers riser 1-11 panels
Pumptrol
renewal parts XML international XMLF electronic XMLG electronic pressure transmitters, XMLG electronic Preventa machine safeguarding products Preventa XPS safety controller Safety PLC safety relays prewired connection system
Advantys TeleFast 2
pricing Integrated Power Center NF panelboards pricing procedure NF panelboards NQ panelboards professional dimmer, C-Bus ProWORX 32 automation products proximity sensors accessories food, beverage pharmaceutical / solid state ouput XS basic series XS plastic rectangular
Words in
i -13
1-4 7-12, 7-14 1-12 1-10 1-6 1-6 1-5 1-5 1-8 1-7 1-7 1-7 1-10 1-10 1-3 1-2 1-3 1-3 1-3 1-3 1-3 1-3 9-10 9-10 9-10 9-10 7-15 7-14 9-10 9-11 14-12 1-2 7-14
QO load center
accessories auxillary gutter convertable main lug kits indoor, 1 main circuit breaker indoor, main lug main circuit breaker kits main lugs, main circuit breaker rainproof metallic enclosure rainproof non-metallic enclosure rainproof, main lugs, main circuit breaker special applications tap kit QO plug-on arc-fault circuit breaker circuit breakers EPD, overload, short circuit class B ground fault protection circuit breaker GFI, Qwik-Gard class A ground fault protection circuit breaker HID, high intensity discharge lighting circuit breaker HM, high magnetic trip circuit breaker K, key operated circuit breaker SWN, switch neutral common trip circuit breaker QOB bolt-on circuit breakers Visi-Trip indicator NQ panelboards QOB-EPD QOB-HM QOB-VHGFI QOU accessories miniature circuit breakers QWIK-GARD circuit breaker ground fault circuit interrupter Qwik-Gard branch circuit breakers Qwik-Gard circuit breakers Qwik-Open QYU supplementary protectors
R
radio frequency identification Osisense RFID rainproof meter centers ratings, safety switches receptacle Crouse-Hinds Style 2 receptacle module, controlled panels receptacle switches, safety switches Relay relay sockets Square D relays 10 Amp 20 Amp 8-Channel Low Voltage AC control Type X AC latching Type X AC master Type X AC timing Type X 20-9, 20-12 2-8, 2-10, 2-12 3-6 Hubbellock 3-10 15-6 3-10 23-2 23-13 5-16 5-16 5-16 23-21 23-21 23-21 23-21
23-10 alternating changeover 5-16 current measurement 23-30 DC control Type X 23-22 DC latching Type X 23-22 DC timing Type X 23-22 DC utility Type X 23-22 liquid level 23-34 overload 18-2 18-5 phase failure 23-31, 23-35 Sepam series digital protective 4-24 snapmount sockets 23-13 solid state interface 23-41 utility auxiliary Type X 23-22 voltage measurement 23-32 remote alarm indicators medical products 15-6 5-12 remote controls, C-Bus 5-29 remote modem support, Powerlink 6-2 remote monitor, surge protective device (SPD) remote source controller, Powerlink 5-28 renewal parts 22-26 pressure, vacuum, and float switches replacement parts 15-6 medical products standard duty control stations 19-100 TeSys F-Line contact kits 18-13 contact kitsarc chambers 18-13 Type K and SK 19-89 replacement parts kits contact units for melting alloy type overload relays 16-117 contactors 16-116 fuse block 16-124 starter accessories 16-117 starters 16-116 replacement parts kits relays 16-116 reversing and two speed 16-7 manual starters reversing combination starters NEMA rated coil voltage codes 16-54 dimensions 16-56 16-57 fusible disconnect switch type 16-50 Mag-Gard circuit breaker 16-52 16-53 MCP circuit breaker 16-52 non-fusible and fusible disconnect switch type 16-51 thermal magnetic circuit breaker 16-54 16-55 reversing contactors TeSys D-Line 18-14 TeSys F-Line 18-15 16-10 reversing drum switches 16-10 dimensions NEMA 1, 3R, 4 & 13 without overload protection 16-10 reversing manual switches 16-3 reversing mini-contactors 18-25 reversing two-speed magnetic starters 16-61 2-5 ring and ringless devices meter centers ringless meter sockets 2-2 riser panels, QO and Homeline load center 1-11 12-6 riser, Busway rotary cam switches 19-121 rotary handles 7-37
ALPHABETICAL LISTING
i -14
Words in
Saturn keypads
SB/SF switchboards SCCR short circuit current rating sealed
S
safety cable pull switches interlock switches limit switvches safety architectures Safety at Work AS-i 25-8 25-7 25-8 25-3 25-2 25-3, 25-5 25-3, 25-5 25-2 25-4 25-7 25-2 25-7 25-7 25-8 25-2, 25-8 25-8 25-8 25-2 25-3
14-12 14-4 6-6 21-8 7-9 2-9 7-2 7-4 4-27 7-32 4-25 19-69 19-29 19-49 19-18 7-44 23-30 23-34 23-33 23-32 23-33 23-34 23-34 23-32 7-46 20-2 20-5 20-10 4-26 4-25 4-24 4-26 4-27 4-25 16-102 9-4 9-3 9-2 9-40 12-7
AS-i
AS-Interface safety controllers XPSMC safety interlock switch products safety interlock switches XCS xcs XCSDM non-contact safety limit switches XCS XCSM XCSP/XCSD safety PLCs XPSMF safety relays XPS safety relays XPS safety switches accessories
25-5 25-2 25-3 25-8 3-3 Appleton Powertite receptacle 3-10 class H, R, J, L fuse provisions 3-5 class R fuse kits 3-11 cover viewing window 3-13 Crouse-Hinds Arktite receptacle 3-10 dimension 3-3 dimensions 3-14 double throw 3-16 3-17 electrical interlock kits 3-3, 3-11 equipment grounding kits 3-12 fuse puller kits 3-3 fusible and non-fusible 3-16 general duty 3-2 heavy duty 3-4 316 grade stainless steel, NEMA 3, 3R, 4, 4X, 5, 12 3-7 applications 3-7 fiberglass reinforced polyester enclosures, NEMA 4X 3-7 Hubbellock receptacle 3-10 internal barrier kits 3-11 key interlock systems 3-13 Krydon enclosures, NEMA 4X 3-7 lock-on provisions 3-13 lug data 3-3, 3-14 lug kits 3-13 NEMA 7 and 9 3-7 NEMA Type 4, 4X, 5, 7, 9 and 12 3-15 neutral assemblies 3-12 ratings 3-6 receptacle switches 3-10 single throw non-fusible 3-6 special accessories 3-11 safety systems, other products 25-2
Words in
i -15
ALPHABETICAL LISTING
shipping Integrated Power Center Integrated Power Center 2 short circuit current rating, SCCR shunt trip circuit breakers panelboards single throw non-fusible safety switches single-phase transformers slow trip, thermal unit selection SMS ordering information Socket meter, E5600, PowerLogic soft starts Software, C-Bus solid neutral accessories Solid State Relays solutions, utilities space heaters, Busway special applications QO load center specifications limit switches
Sumptrol
10-3 10-4 7-28 9-37 3-6 14-2 16-125 4-13 26-2 5-22 16-122 23-43 4-17 12-16 1-10 21-8 11-4 9-40, 11-4 11-5 24-2 24-3 24-4 18-38 12-4 19-100 19-114 15-1 15-4 12-6 16-117 16-118, 18-34 16-121 16-118 18-33 16-121 16-116 16-117 13-6 5-31 5-31 5-31 5-31 5-31 5-31 5-31 5-30 5-30 9-18 4-15 11-18 22-21 22-22
Words in
Speed-D
SB/SF switchboards
Speed-D switchboards
spring clip blocks, AB1RR spring clip terminals, AB1RR spring terminals, motor protectors standard components, Busway standard duty control stations replacement parts standard duty pistol grips XAC standard equipment
Iso-Gard
surgical facility panels standard straight lengths, Busway starter accessories replacement parts kits starters accessories control circuit fuse holder cover-mounted control units GV2 and GV3 manual starter and protector power pole adders replacement parts kits universal baseplate straight sections, Wall Duct structured wiring structured wiring system accessories combination video/telephone hubs data hubs
open tank float switches 22-21 22-22 supervisory module controlled panels 15-6 supplementary protectors QYU 7-14 26-18 support, AC drives supports, Busway 12-16 surge arrester, hard-wired secondary 6-6 surge protective device (SPD) 6-2 flush mounting integral switch 6-2 modular and non-modular 6-2 remote monitor 6-2 surge protective devices 6-2 externally mounted non-modular external SPD 6-2 replacement modules 6-3 Surgebreaker Plus accessories 6-7 Surgebreaker Plus 6-7 accessories transient voltage surge suppressor 6-7 Surgelogic 11-16 Transient Voltage Surge Suppression, TVSS TVSS 9-12, 9-19, 9-33 Model IMA I-Line panelboards 9-33 switch enclosure, MiniBreak compact height 11-7 switch products, safety interlock 25-7 switchboards 11-1 Power-Style 11-2 switchboards, Speed-D 9-40 switches 19-119 19-120 foot industrial snap 21-6 rotary cam 19-121 switchgear 11-1 medium voltage metal-enclosed HVL 11-12 11-14 HVL/cc 11-9 MiniBreak 11-7 11-6 switchgear, low voltage metal-enclosed drawout 4-21 system integration, PowerLogic
ALPHABETICAL LISTING
T
tables 1150, thermal unit selection tap kit, QO load center tee, Busway telephone hubs structured wiring system temperature control relays Tenant circuit breakers meter center accessories meter centers Tenant Metering software (TMS) terminal block kits transformers terminal block, tie point terminal blocks assemblies terminal data 16-130 16-148 1-10 12-6 5-31 23-34 2-6 2-6 4-13 14-11 16-122 24-15 9-39, 9-41 9-38 9-38
Multi-Link
video hubs structured wiring system telephone hubs sub-feed circuit breaker cabinet data NF panelboards submetering sub-station circuit breakers sump application float switches 9036D, G 9036FG i -16
I-Line
NF NQ
TeSys
AK5 panel, busbar system 18-39 contactors 18-38 D-Line 3- and 4-pole reversing contactors 18-6 D-Line non-reversing contactors 18-2, 18-4 GV2 and GV3 manual starters and protectors, accessories 18-34 GV7 manual starters and protectors, accessories 18-35 IEC style industrial control relays 23-15 K-Line accessories 18-27 K-Line contactors 18-27 manual starters and protectors, accessories 18-36 Tesys D-line and F-line 7-28 TeSys D-Line 18-11 accessories automatic-manual-stop control modules 18-10 coil suppressors cabling accessories 18-9 electronic serial timer modules 18-10 electronic timers and interface modules 18-10 interface modules 18-10 low voltage ride through module 18-10 reversing contactors 18-14 TeSys D-Line & F-Line 18-8 auxiliary contacts mechanical latch 18-8 time delay 18-8 TeSys F-Line 3-pole reversing contactors 18-7 TeSys F-Line contactors 18-12 TeSys F-Line non-reversing contactors 18-3, 18-5 TeSys F-Line reversing contactors 18-15 TeSys GV2 manual starters and protectors accessories 18-37 TeSys T motor management system 16-93 configuration with PowerSuite 16-95 LTMCU compact display 16-94 LTME expansion module 16-94 LTMR controller 16-94 Magelis display 16-94 TeSys T and SMS PowerLogic 16-95 motor management systems HMIhuman machine interface 16-94 thermal overload relays NEMA rated bimetallic 16-98 dimensions 16-99 16-101 melting alloy 16-90 solid state overload relay 16-91 thermal unit selection 16-125 calculation of trip current rating 16-128 general 16-125 horsepower and voltage 16-129 slow trip 16-125 tables 1150 16-130 16-148 thermal units, mounting 16-129 thermal-magnetic circuit breakers 7-49 F-frame
15-6 23-28 23-29 26-1 5-9 19-7 19-6 26-18 10-2 10-6 12-7 14-1 14-8 14-8 14-10, 14-17 14-11 14-4 14-3 14-20 14-18 14-7 14-8 14-9 14-7 14-9 14-6 14-10, 14-18 14-4 14-2 14-6 14-7 14-7 14-14 14-20 14-11 14-12 14-14 14-6 14-5 14-9 11-12 14-4 14-12 14-2 14-11 14-9 14-2 14-14 14-16 11-12 14-20 14-3 16-121 11-16
IPC2
merchandise configurations transformer taps, Busway transformers 120115,000 volts single-phase indoor three-phase indoor accessories brackets buck and boost copper wound current disconnects drive isolation dry type EE harmonic mitigating EE medium voltage, dry type EE NL enclosures export model general purpose dry type high harmonic loads DIT HMT industrial control instrument lug
Power-Cast
sealed sealed Mini Power-Zone single-phase terminal block kits three- and single-phase, medium voltage three-phase Type T Type TF
Uni-Cast
voltage
Watchdog
transient suppression module accessories Transient Voltage Surge Suppression
Words in
i -17
ALPHABETICAL LISTING
QMB 9-39 terminal blocks IEC style 24-2 24-9, 24-11 24-12 NEMA style 24-13, 24-15 test block bypass sockets, meter sockets 2-3
L-frame Thermal-Magnetic Circuit Protectors thermal-magnetic circuit protectors thermostats, Busway three tier AB1DD, AB1ET three-phase transformers tie point terminal block time delay, TeSys D-Line & F-Line timers medical products plug-in electronic pneumatic TOC touch screens, C-Bus Tower Lights and Beacons tower lights and beacons training, AC drives transformer combo
Transparent Ready
automation products motor control centers trim, dual output voltage panels trip system, Micrologic trip units
ALPHABETICAL LISTING
6-7 11-1 27-6 17-2 15-5 7-52 11-6 11-16 12-13 9-12, 9-19, 9-33 27-2 24-6 24-7 16-59 16-59 16-62 16-60 16-3 16-59 24-19 11-18 19-70 19-69 19-85 19-9 19-89 19-82 19-94 8-20 14-14 14-16 16-29
V
vacancy sensors residential wall switch vacuum circuit breaker vacuum substations, Motorpact vacuum switches renewal parts Valox VAR compensator (HVC) hybrid variable depth disconnect switches Vario manual motor control switches Vario motor disconnect switches video hubs structured wiring system Vigirex ground-fault relay system Vijeo Designer automation products voltage measurement relays voltage testers QO and Homeline load center voltage transformers 5-24 11-15 11-18 22-1, 22-17 22-26 20-10 4-36 8-16 8-17 8-4 8-3 5-31 7-47 27-4 23-32 1-13 14-20
Micrologic
TVSS plug-in units, Busway Surgelogic Twido Nano, automation products two tier blocks AB1ET AB1ETN two-speed combination starters circuit breaker type dimensions disconnect switch manual switches non-combo starter Type FB fuseholders Type FVR Powersub circuit breakers Type K heavy duty pilot lights Type K, KX, and SK selector switch guide Type K, SK accessories common operators, contact blocks replacement parts Type K, SK and KX electrical components Type KX accessories type T disconnect switches transformers Type TF transformers Type W non-reversing vacuum starters
W
Wall Duct accessories components fittings straight sections Watchdog transformers Web-enabled ethernet communication devices Web-enabled network components WebPageGenerator Well-Guard pump panels Whole House NEMA 3R Wireless Control Systems, C-Bus wiring, structured 13-4 13-6 13-4, 13-6 13-6 13-6 14-3 11-1 4-19 4-19 16-81 16-83 6-7 5-6, 5-23 5-31
U
UL Listed 500 Vdc circuit breakers ULTEM ultrasonic sensors unfused reducer Busway 7-34 20-10 20-10 12-7 11-12 11-12 11-17 11-18 11-17 27-2 27-2 27-2 16-117 7-45 4-23 4-17 23-22
X
XAC contact blocks enclosures standard duty pistol grips XAC standard duty operators accessories XAL 22 mm control stations XAP 22 mm accessories enclosures 19-4 19-5, 19-66 19-68, 19-76 19-78, 99 XB4 accessories common operators, complete with contact blocks complete devices electrical components illuminated operators pilot lights selector switches specialty operators 19-114 19-114 19-114 19-116 19-96 19-98 19-98 19-
Uni-Cast
transformer connections transformers unit substation distribution section MV controllers transformer section Unity Application Generator unity application software automation products Unity Pro software for controllers universal baseplate starters universal power circuit breakers, Masterpact university, power management utilities, solutions utility auxiliary relays Type X
i -18
Words in
XB5 19-60 accessories common operators, complete with contact blocks 19-8 complete devices 19-42 electrical components 19-55 pilot lights 19-51 selector switches 19-49 specialty operators 19-50 XB5 20 mm 19-123 19-124 components XB6 accessories 19-20 characteristics and complete devices 19-12 electrical components 19-15 illuminated operators 19-16 keyed selector switches 19-19 non-illuminated operators 19-17 selector switches 19-18 XCKJ precision switches with direct acting contacts limit switches 21-27 XCKL Components 21-21 XCKS 21-19 XCS 25-2, 25-7 safety interlock switches safety limit switches 25-2, 25-8 25-7 XCSDM non-contact safety interlock switches 25-8 XCSM safety limit switches XCSP/XCSD 25-8 safety limit switches XML international pressure switches 22-8 22-10 XMLF electronic pressure switches 22-6 22-7 XMLG electronic pressure transmitters and switches 22-4 25-2 25-3, 25-5 XPS safety relays XPSMC safety controllers 25-2 25-4 XPSMF 25-4 PLCs safety PLCs 25-2 25-3 25-4 XPSMF Safety PLCs X-ray indicator controlled panels 15-6 20-7 XS basic series proximity sensors
XS plastic rectangular proximity sensors 20-5 20-6 XS plastic tubular proximity sensors XUB tubular photoelectric sensors 20-2 XUBL Laser Sensors 20-3 20-3 XUBT Sensors XUM miniature, XUK and XUX compact 20-4 photoelectric sensors XUSL light curtains 25-2, 25-6 XUSLP perimeter guard, body detection 25-6 XUSLT 2-box light curtain 25-6 19-106 XVB 70 mm 19-108 accessories components 19-107 XVDLS 45 mm mini beacons 19-104 19-105, 19-112 XVP 50 mm illuminated indicating banks 19-111 accessories components 19-110 19-103 XVR rotating lights 25-2, 25-8 XY2 cable pull switches
Z
ZCKD01 ZCKD02 ZCKD31 ZCKD39 ZCKD41 ZCKD49 ZCKD59 ZCKS 21-19 21-19 21-19 21-19 21-19 21-19 21-19 21-19 23-38 23-36 23-39 23-2
Zelio
analog interface modules counters Logic 2 smart relays plug-in relays
Words in
i -19
ALPHABETICAL LISTING
ALPHABETICAL LISTING
i -20
Words in
A100 thru A250............................................................. 1-22, 2-3 A200L thru A400L......................................................... 1-22, 2-3 A5J ........................................................................................ 2-3 AA...................................................................................... 21-34 AAC ..................................................................................... 7-36 AAP .............................................................................. 1-22, 2-3 AB...................................................................................... 21-34 AB1AA135U2BL thru AB1AATP235U4 ............................. 24-10 AB1AB10M32 thru AB1AB8R35........................................ 24-12 AB1AC2............................................................................... 24-2 AB1AC24 thru AB1ACN16BL.............................................. 24-5 AB1B510 thru AB1B890 .................................................... 24-11 AB1BB18535 thru AB1BC9535 ........................................... 24-9 AB1BV5 thru AB1BV8 ....................................................... 24-11 AB1CT1 and AB1CT2 ......................................................... 24-9 AB1CT215 ........................................................................... 24-4 AB1D11435U....................................................................... 24-9 AB1DDP235T thru AB1DDP235ULP .................................. 24-7 AB1ET3235U thru AB1ETNTP435U .......................... 24-6, 24-7 AB1FC335U ........................................................................ 24-9 AB1FF235U......................................................................... 24-9 AB1FU10135U thru AB1FUSE435U6XM............................ 24-8 AB1FV135U......................................................................... 24-9 AB1GA thru AB1GZ........................................................... 24-11 AB1PC15........................................................................... 24-12 AB1PS4 ...................................................................... 24-8, 24-9 AB1R0 thru AB1R13.......................................................... 24-11 AB1RRN1035U2BL thru AB1RRNTPAC642.............. 24-3, 24-4 AB1RT and AB1RV ........................................................... 24-11 AB1SA1 thru AB1SA3 ....................................................... 24-11 AB1SC435U and AB1SC435U2PT ..................................... 24-9 AB1SF435U thru AB1SF520M ................................... 24-4, 24-8 AB1SR6............................................................................. 24-11 AB1SV1 and AB1SV2 ................................................ 24-4, 24-8 AB1TC01 ............................................................................. 24-9 AB1TC3 ............................................................................... 24-9 AB1TE ................................................................................. 24-6 AB1TEN3 and AB1TEN4..................................................... 24-7 AB1TF ................................................................................. 24-8 AB1TP1035U thru AB1TP635U .......................................... 24-6 AB1TP215 ........................................................................... 24-4 AB1VV215 thru AB1VVN7035UBL............................. 24-4, 24-5 ABL1REM12050 thru ABL1REM24100............................. 23-37 ABL1RPM12083 thru ABL1RPM24100............................. 23-37 ABL7RM24025 thru ABL7RP4803 .................................... 23-37 ABL8MEM05040 thru ABL8REM24050 ............................ 23-37 ABL8RPM24200................................................................ 23-37 ABL8RPS24030 thru ABL8WPS24400 ............................. 23-37 ABR1E101M thru ABR1E418E ......................................... 23-42 ABR1S102B thru ABR1S618E .......................................... 23-42 ABR2E111M thru ABR2SB312B ....................................... 23-42 ABS2EA02EF thru ABS2SC02EB..................................... 23-41 ACE937 thru ACE990.......................................................... 4-26 ACE9492 ............................................................................. 4-26 ACF13EC thru ACF88WF ................................................... 12-5 ACP and ACPL............................................................. 1-22, 2-3 ACP1034CD thru ACP6034BC ........................................... 3-10 ACP2EC thru ACP4WF ....................................................... 12-4 ACPA and ACPLA ................................................................. 2-3 ACS ..................................................................................... 7-38 AF2308G10ST thru AF2540GLFM22.................................. 12-5 AH...................................................................................... 21-34 AHP ..................................................................................... 7-38 AK...................................................................................... 21-34 AK5JB143 thru AK5JB1410 .............................................. 18-39 AK5PA231 thru AK5PA232S............................................. 18-39 AK5PC33 and AK5PC33L ................................................. 18-39 AK5PE27 ........................................................................... 18-39 AL100FA..................................................................... 7-49, 9-23 AL100FD ............................................................................. 9-15 AL100TF.............................................................................. 7-49 AL1200P24K .............................................................. 7-39, 9-23 AL1200P25K and AL1200P25K4 ........................................ 7-39
2009 Schneider Electric All Rights Reserved
AL1200P6KU and AL1200P6KU4....................................... 7-39 AL1200P7KU and AL1200P7KU4....................................... 7-39 AL1200R53K .............................................................. 7-39, 9-23 AL150FA ............................................................................. 7-49 AL150HD and AL175JD ...................................................... 7-39 AL1650 thru AL1802 ......................................................... 21-34 AL20DTF ............................................................................. 3-13 AL2500RK ........................................................................... 7-39 AL250JD ............................................................................. 7-39 AL250KA and AL250KI ....................................................... 7-50 AL2820 .............................................................................. 21-34 AL30FD ............................................................................... 9-15 AL400LA .................................................................... 7-51, 9-23 AL400LH7 ........................................................................... 7-51 AL50FA ............................................................................... 7-49 AL600LI5 thru AL600LI35 ................................................... 7-51 AL800M23K and AL800M23K4........................................... 7-39 AL800P6K and AL800P6K4 ................................................ 7-39 AL800P7K and AL800P7K4 ................................................ 7-39 AL800SN ............................................................................. 7-58 AL900MA ............................................................................ 9-23 ALAM .................................................................................. 7-53 ALTI..................................................................................... 7-53 AM ..................................................................................... 21-34 AM1DE200 ............................................................. 23-19, 24-12 AM1DL201 ........................................................................ 18-39 AM1DP200 .................................................. 18-11, 23-19, 24-12 AM1ED200 ........................................................................ 24-12 AMT840............................................................................... 4-26 AO ..................................................................................... 21-34 AP2308G10ST thru AP2540G10ST.................................... 12-5 AP30210 thru AP506LTO ................................................... 12-4 APJ3485 thru APJ10487 ..................................................... 3-10 APP2D1 thru APP2R4H4 .................................................. 18-38 AR ..................................................................................... 21-34 AR1MA01 thru AR1MC019 ............................................... 24-21 AR1SB2 and AR1SB3....................................................... 24-11 AR1SC01 thru AR1SC03 .................................................. 24-21 ARP00026 .................................................... 1-22, 2-3, 2-6, 2-15 ARP00118 thru ARP00427 ................................................... 2-3 ARP040 thru ARP100 ......................................................... 7-53 ASILUFC5 and ASILUFC51 .............................................. 18-31 AT1HB2............................................................................. 24-21 AT1PA1 thru AT1PA7 ....................................................... 24-21 ATS01N103FT thru ATS01N285LY ....................... 26-15, 26-16 ATS48C11Y thru ATS48M12Y.......................................... 26-17 ATSU01N206LT thru ATSU01N232LT .................. 18-32, 26-15 ATV21H075M3X thru ATV21WU75N4 ............................... 26-4 ATV31C018M2 thru ATV31HU75S6X ....................... 26-4, 26-5 ATV58HD12M2ZU thru ATV58HU90N4ZU....................... 26-11 ATV61H075M3 thru ATV61HU75Y ............................ 26-6, 26-7 ATV71H037M3 thru ATV71HU75Y ............................ 26-7, 26-8 AZ5DE005 thru AZ5DE025 ............................................... 24-20 B075 thru B400 ........................................ 1-18, 1-22, 3-11, 3-19 BCAP ....................................................... 1-18, 1-22, 3-11, 3-19 BCH and BCHB................................................................... 7-15 BCM42 thru BCM42SRC1 .................................................. 4-16 BCMSC12 thru BCMSC42H ............................................... 4-16 BCPMA042D thru BCPMC184D ......................................... 4-16 BCV and BCVB ................................................................... 7-15 BH20512 thru BH2096 ........................................... 21-28, 21-34 BMK2Q400.......................................................................... 1-22 C125RB............................................................................... 1-19 C2M200S ............................................................................ 1-19 C4L200S ............................................................................. 1-19 CA2KN22 thru CA2KN407 ................................................ 23-18 CA2SK11 ............................................................... 16-71, 23-20 CA2SK11 thru CA2SKE20 ................................................ 23-20 CA3KN22 thru CA3KN407 ................................................ 23-18 CA3SK11 and CA3SK20................................................... 23-20 CA4KN22 thru CA4KN407 ................................................ 23-18 CAB12 and CAB30 ............................................................. 4-11 CAB4 ................................................................................... 4-11
i-21
ALPHA-NUMERIC LISTING
CAD32 thru CAD506 ......................................................... 23-15 CBTMB and CBTMBRK ...................................................... 7-53 CCA612 thru CCA785 ......................................................... 4-26 CCT640 ............................................................................... 4-26 CF2308G10ST thru CF2550GLFM21 ................................. 12-5 CGJD1 thru CGJD9............................................................. 8-22 CL0306F.............................................................................. 3-13 CL10F thru CL60F............................................................... 3-13 CLFSO................................................................................. 9-14 CM200S............................................................................... 1-19 CM3250 and CM3350 ......................................................... 4-10 CM4000T and CM4250 ....................................................... 4-11 CMB363 thru CMB381 ........................................... 14-10, 14-11 CMDLC and CMDVF ........................................................... 4-11 CMELK4 ............................................................1-22, 2-10, 2-12 CP2308G10ST thru CP2550G10ST.................................... 12-5 CP30210 thru CP506LTO ................................................... 12-4 CSH30 thru CSH200 ........................................................... 4-26 CT1000SC and CT3000SC ................................................. 4-36 CTC3610CU and CTC3612CU ........................................... 9-40 CTC364CU thru CTC368CU ............................................... 9-40 CTFCL500058 ..................................................................... 4-36 CU100FA and CU100TF ..................................................... 7-49 CU100FD............................................................................. 9-15 CU1200P24K....................................................................... 7-39 CU1200P25K and CU1200P25K4....................................... 7-39 CU1200R53K ...................................................................... 7-39 CU12L400CB thru CU12L400FN ........................................ 1-21 CU150HD and CU250JD..................................................... 7-39 CU250KA............................................................................. 7-50 CU250P1K........................................................................... 7-39 CU400LA ............................................................................. 7-51 CU600LI5 thru CU600LI35 .................................................. 7-51 CU800M23K and CU800M23K4 ......................................... 7-39 CU816D400CB thru CU816D400FN ................................... 1-21 CUM400CB ......................................................................... 1-21 CVM and CVMT .................................................................. 4-11 CYA060HD thru CYA1200R7.............................................. 7-40 D10S1 thru D12FR64 .......................................................... 8-12 D211N thru D326NTR ........................................................... 3-2 DASKP100 thru DASKS600 .............................................. 14-11 DASKP1000 thru DASKS2000 .......................................... 14-11 DFCC1 thru DFCC3V .......................................................... 24-8 DGL36150E20 thru DGL36600F60 ..................................... 7-25 DJL36000S40 and DJL36000S60 ....................................... 7-33 DJL36150E20 thru DJL36600F60 ....................................... 7-25 DL1BDB1 thru DL1BKG8 ................................... 19-10819-111 DL1BLB thru DL1BLM ..................................................... 19-108 DL1CB006 thru DL1CF220 .......................19-40, 19-61, 19-116 DL1CJUS0063 thru DL1CJUS1205 ................................ 19-116 DLL36150E20 thru DLL36600F60....................................... 7-25 DOCBINDERIE5 thru DOCUGUIDE205 ............................... 4-4 DR2SC0030 thru DR2SC4700 .......................................... 18-20 DR5TE4S thru DR5TF4V .................................................. 18-18 DRK30 thru DRK600 ............................................................. 3-2 DS200EK2D ........................................................................ 3-19 DS468GKD.......................................................................... 3-19 DSM303............................................................................... 4-26 DT100SG thru DT600NKD ......................................... 3-173-19 DTU222 thru DTU663AWK ........................................ 3-17, 3-18 DU221RB thru DU326 ........................................................... 3-2 DVBF and DVBS ................................................................. 15-5 DVC ..................................................................................... 15-5 DVT122 thru DVT753 .......................................................... 15-5 DX1AP25 and DX1AP26 ................................................... 18-16 DZ2FF1 thru DZ2FX6........................................................ 18-12 DZ5CA002 thru DZ5CE063............................................... 24-20 DZ5MB201 ........................................................................ 24-12 E480510SQD thru E488010SQD ........................................ 4-14 ECB14015G3 thru ECB34020G3 ........................................ 5-25 ECC21 ................................................................................. 4-11 ECT80200 thru ECT80800 .................................................. 4-14 EDB14015 thru EDB34125.................................................. 9-15
i-22
EDB14015EPD thru EDB14050EPD ...................................9-15 EDI32 ...................................................................................4-15 EDPA and EDPAF ...............................................................9-14 EE1000T151HCT thru EE1000T79H ...................................14-2 EE100S3534H thru EE100S61H ............................... 14-2, 14-3 EE112T151HCT thru EE112T67H ............................. 14-2, 14-3 EE112T3HFISCUNL thru EE112T3HISNLP ........................14-6 EE150T151HCT thru EE150T67H ............................. 14-2, 14-3 EE150T3HFISCUNL thru EE150T3HISNLP ........................14-6 EE15S3534H thru EE15T67H.................................... 14-2, 14-3 EE15T3HFISCUNL thru EE15T3HISNLP ............................14-6 EE167S13H thru EE167S62H .............................................14-9 EE167S3534H thru EE167S61H .........................................14-2 EE225T151HCT thru EE225T67H ............................. 14-2, 14-3 EE225T3HFISCUNL thru EE225T3HISNLP ........................14-6 EE250S13H thru EE250S62H .............................................14-9 EE250S3534H and EE250S3H............................................14-2 EE25S3534H thru EE25S61H ................................... 14-2, 14-3 EE300T151HCT thru EE300T68HFCU...................... 14-2, 14-3 EE300T68HFISCUNL thru EE300T68HISNLP ....................14-6 EE30T151HCT thru EE30T67H ................................. 14-2, 14-3 EE30T3HFISCUNL thru EE30T3HISNLP ............................14-6 EE333S13H thru EE333S62H .............................................14-9 EE333S3534H and EE333S3H............................................14-2 EE37S3534H thru EE37S61H ................................... 14-2, 14-3 EE45T151HCT thru EE45T67H ................................. 14-2, 14-3 EE45T3HFISCUNL thru EE45T3HISNLP ............................14-6 EE500T151HCT thru EE500T79H ............................. 14-2, 14-3 EE500T68HFISNL thru EE500T68HISNLP .........................14-6 EE50S3534H thru EE50S61H ................................... 14-2, 14-3 EE750T151HCT thru EE750T79H ............................. 14-2, 14-3 EE75S3534H thru EE75T67H.................................... 14-2, 14-3 EE75T3HFISCUNL thru EE75T3HISNLP ............................14-6 EGB14015 thru EGB34125..................................................9-15 EGB14015EPD thru EGB14050EPD ...................................9-15 EIK031 and EIK032...................................................... 3-3, 3-11 EIK1 and EIK2.......................................... 3-3, 3-11, 3-19, 16-81 EIK40601 and EIK40602......................................................3-11 EJB14015 thru EJB34125....................................................9-15 EJB14015EPD thru EJB14050EPD .....................................9-15 EK400DTU2 .........................................................................3-19 EMB1010 thru EMB3164 .....................................................4-15 EMBK3 .................................................................................4-15 EMBOND .............................................................................4-15 EMCB...................................................................................4-15 EMCT010 thru EME3164 .....................................................4-15 EMFP1 thru EMFP3 .............................................................4-15 EMT1225CB and EMT3225CB ..............................................2-3 ENA485................................................................................4-15 EXR......................................................................................15-6 EZM11000CB thru EZM11200TBU......................................2-10 EZM112225 thru EZM1225TB ................................... 2-102-11 EZM125QOA.............................................................. 2-16, 2-15 EZM1400CB thru EZM1800TBU..........................................2-10 EZM1600FTLK3...................................................................2-15 EZM1CORNER thru EZM1TRANR......................................2-15 EZM31000CB thru EZM3800TBU.............................. 2-122-14 EZM3BUSLB thru EZM72MC ..............................................2-15 EZMH112225 thru EZMH116125CUX .................................2-11 EZMH312225 thru EZMH316125CUX .................................2-13 EZMK111400 and EZMK112400 .........................................2-11 EZMK311400 thru EZMK332400 .........................................2-14 EZML111225 thru EZML114225D .......................................2-11 EZML311400 thru EZML334225D ............................. 2-13, 2-14 EZMPCP ..............................................................................2-15 EZMR112225 thru EZMR116125CUX .................................2-11 EZMR312225 thru EZMR334225CU ...................................2-13 EZMSK2...............................................................................2-15 EZMT111225 thru EZMT113225 .........................................2-11 EZMT311225 thru EZMT333225 .........................................2-13 FA100A thru FA100S ...........................................................7-56 FA14035A thru FA14100C...................................................9-24 FA24015AB thru FA24100BC ..............................................9-24
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
FA26015AB thru FA26100BC ............................................. 9-25 FA32015 thru FA32100 ....................................................... 9-24 FA34015 thru FA34100 ....................................................... 9-24 FA36015 thru FA36100 ....................................................... 9-25 FAL12015 thru FAL36100 ................................................... 7-49 FAO ..................................................................................... 9-14 FC1IMA12C thru FC4IMA24C............................................... 6-4 FH16015A thru FH16100C.................................................. 9-25 FH26015AB thru FH26100BC ............................................. 9-25 FH36015 thru FH36100....................................................... 9-25 FHL16015 thru FHL36100................................................... 7-49 FHL26000M......................................................................... 7-33 FHL36000M and FHL3600015M ......................................... 7-33 FHL3603013DC thru FHL3610016DC ................................ 7-34 FI1IMA12C thru FI8IMA24C .................................................. 6-4 FI26100AB thru FI26100CB ................................................ 9-25 FI36100 ............................................................................... 9-25 FIL26020 thru FIL36100 ...................................................... 7-49 FJA14015A thru FJA14070B............................................... 9-24 FK400 .................................................................................. 1-22 FPK03 and FPK0610............................................................. 3-3 FY14015A thru FY14030C .................................................. 9-24 G1414 and G1426 ............................................................... 13-6 G1500T12 thru G1500T36 .................................................. 13-6 G1735S ............................................................................... 13-6 G19103................................................................................ 13-6 GB2CB05 thru GB2CD20.................................................. 24-17 GC12 ................................................................................... 7-46 GC200A thru GC200E......................................................... 7-46 GC30 ................................................................................... 7-46 GC4 ..................................................................................... 7-46 GCDSP................................................................................ 7-46 GFI2PA......................................................................... 1-4, 7-12 GFM150HD and GFM250JD ............................................... 7-48 GFM25CT............................................................................ 7-48 GJL36003M01 thru GJL36075M06 ..................................... 7-30 GJL36015 thru GJL36100 ................................................... 7-24 GK2AF01........................................................................... 18-37 GLED................................................................................... 15-6 GS1200I .............................................................................. 15-3 GS1204NI............................................................................ 15-3 GS1AD10 .............................................................................. 8-8 GS1AE7 and GS1AE71......................................................... 8-7 GS1AH01 .............................................................................. 8-6 GS1AH101 and GS1AH102 .................................................. 8-7 GS1AN11 thru GS1AW903 ................................................... 8-8 GS1DDU3 thru GS1EERU30 ................................................ 8-6 GS2AD11 .............................................................................. 8-8 GS2AE2 thru GS2AHT440 .................................................... 8-7 GS2AM101 thru GS2AM110 ................................................. 8-8 GS2AP73............................................................................... 8-8 GS2EEU3 thru GS2TU3........................................................ 8-6 GS504NI.............................................................................. 15-3 GSA thru GSS ..................................................................... 7-36 GT1218 thru GT1530 .......................................................... 7-46 GT912 thru GT930 .............................................................. 7-46 GTK03 and GTK03C .................................................... 3-3, 3-12 GTK0610 and GTK0610C ............................................ 3-3, 3-12 GUA thru GUS..................................................................... 7-36 GV1F03 thru GV1L3.......................................................... 18-37 GV2AF01 thru GV2MC02.................................................. 18-37 GV2ME01 thru GV2ME32 ................................................. 18-33 GV2MP01 thru GV2MP04 ................................................. 18-37 GV2P01 thru GV2P32 ....................................................... 18-33 GV2SN13 thru GV2SN37 .................................................. 18-37 GV2V01 ............................................................................. 18-37 GV2V03 ............................................................................. 18-34 GV3G264 and GV3G364................................................... 18-34 GV3G66............................................................................. 18-34 GV3P13 thru GV3P65 ....................................................... 18-33 GV7AB11 thru GV7AU525 ................................................ 18-35 GV7RE100 thru GV7RS80 ................................................ 18-33 GV7V01 ............................................................................. 18-35
2009 Schneider Electric All Rights Reserved
GVAD0101 thru GVAD1010.............................................. 18-34 GVAE1 thru GVAN20 ........................................................ 18-34 GVAS025 thru GVAU505 .................................................. 18-34 GYR .................................................................................... 7-38 GYT ..................................................................................... 7-41 H050 thru H100CP ..................................................... 3-11, 3-19 H100XFA and H100XFA1212 ............................................... 3-7 H1200SNE4 ........................................................................ 3-12 H125 and H125CP ..................................................... 3-11, 3-19 H12LKE2 ............................................................................. 3-13 H150 thru H200CP ..................................................... 3-11, 3-19 H2212AWK thru H225R ........................................................ 3-4 H225XKA .............................................................................. 3-7 H226 thru H228R .................................................................. 3-4 H250........................................................................... 3-11, 3-19 H265 thru H268R .................................................................. 3-5 H300........................................................................... 3-11, 3-19 H321A thru H328R ................................................................ 3-4 H350........................................................................... 3-11, 3-19 H361 thru H368R ........................................................... 3-5, 3-7 H3612AWK and H3612RB .................................................... 3-5 H361AWA and H361AWC .................................................. 3-10 H361DSWA and H361DSWC ............................................. 3-10 H361WA and H361WC ....................................................... 3-10 H362AWA thru H362AWH .................................................. 3-10 H362DSWA and H362DSWC ............................................. 3-10 H362WA thru H362WH ....................................................... 3-10 H363AWA and H363AWC .................................................. 3-10 H363DSWA and H363DSWC ............................................. 3-10 H363WA and H363WC ....................................................... 3-10 H400........................................................................... 3-11, 3-19 H461 thru H466 ..................................................................... 3-5 H600J .................................................................................... 3-5 H600SN and H600SNC ...................................................... 3-12 H60XFA and H60XFA1212 ................................................... 3-7 H663AWK thru H664DS........................................................ 3-5 H800SNE4 .......................................................................... 3-12 H82254 thru H82455 .................................................. 3-17, 3-18 H8LKE2 ............................................................................... 3-13 HC2609DEXF and HC2609DEXS ...................................... 9-23 HC2609EXF and HC2609EXS............................................ 9-23 HC2652B thru HC2692B ..................................................... 9-21 HC2652WP thru HC2886WP .............................................. 9-21 HC2686DB .......................................................................... 9-21 HC2686TF4P and HC2686TS4P ........................................ 9-21 HC2686TFHR and HC2686TSHR....................................... 9-21 HC2SN ................................................................................ 9-23 HC3209EXF and HC3209EXS............................................ 9-23 HC3248B thru HC3291B ..................................................... 9-21 HC3248WP thru HC3291WP .............................................. 9-21 HC3273DB9 and HC3291DB9 ............................................ 9-21 HC4212DEXF and HC4212DEXS ...................................... 9-23 HC4250DB thru HC4486DB................................................ 9-22 HC4250WP thru HC4486WP .............................................. 9-23 HC4SN thru HC8SN............................................................ 9-23 HCM14482N thru HCM36918MP........................................ 9-21 HCM400VCA thru HCM800VCA ......................................... 9-23 HCM41914M ....................................................................... 9-21 HCM48TF and HCM48TS ................................................... 9-21 HCM48TFD and HCM48TSD.............................................. 9-21 HCM50912N thru HCM50918 ............................................. 9-21 HCM64TF thru HCM91TSD ................................................ 9-21 HCN09521MN thru HCN50926 ........................................... 9-21 HCN400VCA and HCN600VCA .......................................... 9-23 HCN52TF thru HCN92TSD ................................................. 9-21 HCP145012N thru HCP50868 ............................................ 9-22 HCP54868SU...................................................................... 9-21 HCPSU8SN and HCPSU8SNCT ........................................ 9-23 HCR12SNCT....................................................................... 9-23 HCR548612U ...................................................................... 9-22 HCR86TF thru HCR86TSD ................................................. 9-22 HCW12SN........................................................................... 9-23 HCW400VCA thru HCW1200VCA ...................................... 9-23
i-23
ALPHA-NUMERIC LISTING
HCW4SN thru HCW8SN ..................................................... 9-23 HCW50TF thru HCW86TS .................................................. 9-22 HCW50TFD thru HCW86TSD ............................................. 9-22 HCWM12SN ........................................................................ 9-23 HD100S ............................................................................... 7-56 HDA260151 thru HDA261506 ............................................. 9-26 HDA36015 thru HDA36150 ................................................. 9-26 HDF36000F06 and HDF36000F15 ..................................... 7-23 HDL26015(C) thru HDL36150(C) ........................................ 7-22 HDL36015T thru HDL36150T.............................................. 7-23 HDMCT050S1 thru HDMCT400S1...................................... 4-14 HDMCVRPLT ...................................................................... 4-14 HDMPMHKIT27................................................................... 4-14 HF13E thru HF88F .............................................................. 12-5 HFV ..................................................................................... 12-5 HGA26000S151 thru HGA26000S156 ................................ 9-26 HGA260151 thru HGA261506............................................. 9-26 HGA36000S15 .................................................................... 9-26 HGA36015 thru HGA36150................................................. 9-26 HGF36000F06 and HGF36000F15 ..................................... 7-23 HGL26000S15..................................................................... 7-33 HGL26015(C) thru HGL36150(C)........................................ 7-22 HGL36000S15..................................................................... 7-33 HGL36015T thru HGL36150T ............................................. 7-23 HGL36100 ............................................................................. 9-5 HJA260151 thru HJA261506............................................... 9-26 HJA36015 thru HJA36150................................................... 9-26 HJF36000F06 and HJF36000F15 ....................................... 7-23 HJL26015(C) thru HJL36150(C).......................................... 7-22 HJL36015T thru HJL36150T ............................................... 7-23 HJL36030M71 thru HJL36150M74...................................... 7-28 HLA26000S151 thru HLA26000S176.................................. 9-26 HLA260151 thru HLA261506 .............................................. 9-26 HLA36000S15 ..................................................................... 9-26 HLA36015 thru HLA36150 .................................................. 9-26 HLEN ................................................................................... 15-6 HLF36000F06 and HLF36000F15....................................... 7-23 HLL26000S15 ..................................................................... 7-33 HLL26015(C) thru HLL36150(C) ......................................... 7-22 HLL36000S15 ..................................................................... 7-33 HLL36015T thru HLL36150T............................................... 7-23 HLL36030M71 thru HLL36150M74 ..................................... 7-28 HLO1 ............................................................1-4, 7-12, 7-15, 9-9 HLW1BL and HLW4BL........................................................ 9-23 HM112T208NCU thru HM112T259NCU ............................. 14-7 HM150T208NCU thru HM150T259NCU ............................. 14-7 HM15T208NCU thru HM15T259NCU ................................. 14-7 HM225T208NCU thru HM225T259NCU ............................. 14-7 HM300T208NCU thru HM300T259NCU ............................. 14-7 HM30T208NCU thru HM30T259NCU ................................. 14-7 HM45T208NCU thru HM45T259NCU ................................. 14-7 HM75T208NCU thru HM75T259NCU ................................. 14-7 HNM1BL and HNM4BL ....................................................... 9-23 HNPSF ................................................................................ 1-25 HOM115 thru HOM2125............................................. 1-14, 1-22 HOM115CAFI and HOM120CAFI ....................................... 1-14 HOM115EPD thru HOM250EPD......................................... 1-14 HOM115GFI Thru HOM250GFI .......................................... 1-14 HOM115HM and HOM120HM............................................. 1-14 HOM1224L125RB and HOM1224M200TC ................ 1-15, 1-16 HOM12L125C thru HOM12M100RB .......................... 1-15, 1-16 HOM1624L125C thru HOM1632U200TC................... 1-15, 1-16 HOM1HT ............................................................................. 1-14 HOM1PA ............................................................................. 1-14 HOM1RK ............................................................................. 1-13 HOM2024L125TC thru HOM2040U200TC ................ 1-15, 1-16 HOM20L125C thru HOM20M100RB .......................... 1-15, 1-16 HOM2150BB thru HOM2200BB ................................. 1-14, 1-22 HOM2175SB ................................................................ 1-12, 6-8 HOM24L125TC thru HOM24M125RB........................ 1-15, 1-16 HOM2HBD........................................................................... 1-14 HOM2PAHA thru HOM2PAVHA.......................................... 1-14 HOM3040L200RB thru HOM3040U200TC ................ 1-15, 1-16
i-24
HOM30L150C thru HOM30M200RB.......................... 1-15, 1-16 HOM4060L200RB thru HOM4060M200RB ............... 1-15, 1-16 HOM40L200C thru HOM40M200RB.......................... 1-15, 1-16 HOM4252L200RB thru HOM4252M200RB ............... 1-15, 1-16 HOM42L225C thru HOM48L125GRB........................ 1-15, 1-16 HOM4RK2HA and HOM4RK2LA .........................................1-13 HOM5RK..............................................................................1-13 HOM612L100RB..................................................................1-16 HOM816L125C thru HOM816U200FTRB.................. 1-15, 1-16 HOMCGK2 ...........................................................................1-13 HOMCRBGK1 ......................................................................1-13 HOME250SPA .....................................................................1-24 HOMFP ...................................................................... 1-13, 1-22 HOML2125 and HOML2225 ................................................1-14 HOMQPA .............................................................................1-14 HOMRBGK2.........................................................................1-13 HOMT1515 thru HOMT3020................................................1-14 HOMT1515215 thru HOMT2020250....................................1-14 HOMTHT..............................................................................1-14 HOMVP1 thru HOMVP16.....................................................1-11 HOMVPL1 and HOMVPL2...................................................1-11 HOMVPRB1 .........................................................................1-11 HP2F thru HP5F...................................................................12-4 HPAFD .................................................................................5-25 HPB......................................................................................15-6 HPLEN .................................................................................15-6 HPPB ...................................................................................15-6 HQO206AB thru HQO206BC...............................................9-24 HQO306 ...............................................................................9-24 HRK1020.............................................3-2, 3-7, 3-11, 9-34, 12-9 HRK30..................................................................................9-34 HRK4060..............................................................................3-11 HT3015 thru HT3150 ...........................................................7-23 HU265 thru HU361AEI...........................................................3-6 HU361AWA and HU361AWC ..............................................3-10 HU361AWK thru HU361DSEI ........................................ 3-6, 3-7 HU361DSWA and HU361DSWC .........................................3-10 HU361DX thru HU361SS............................................... 3-6, 3-7 HU361WA and HU361WC ...................................................3-10 HU362 and HU362A ..............................................................3-6 HU362AWA thru HU362AWH ..............................................3-10 HU362AWK thru HU362DSEI ........................................ 3-6, 3-7 HU362DSWA and HU362DSWC .........................................3-10 HU362DX thru HU362SS............................................... 3-6, 3-7 HU362WA thru HU362WH...................................................3-10 HU363 and HU363A ..............................................................3-6 HU363AWA and HU363AWC ..............................................3-10 HU363AWK thru HU363DS ........................................... 3-6, 3-7 HU363DSWA and HU363DSWC .........................................3-10 HU363DX thru HU363SS............................................... 3-6, 3-7 HU363WA and HU363WC ...................................................3-10 HU364 thru HU664DS.................................................... 3-6, 3-7 HVDSA3 thru HVDSA15 ....................................................11-13 HVL305BG thru HVL317BW ..............................................11-11 HVL405BGL thru HVL515DEWR2H ..................................11-12 HVLC and HVLC2 ..............................................................11-13 HVLCCA14305D thru HVLCCMBB20B20 ............... 11-9, 11-10 HVLCCX3.............................................................................11-9 HVLX3................................................................................11-13 HVMB.................................................................................11-13 HVMB305200 and HVMB305200U......................................11-7 HVMH1 thru HVMX1 ............................................................11-7 IA10CI thru IA24CI ...............................................................15-6 IA1C thru IA9CI ....................................................................15-6 IANC.....................................................................................15-6 IK250AWK............................................................................7-56 IK250DS...............................................................................7-56 IOC44...................................................................................4-11 ION56UNLTD thru IONESQL2005CPU .................................4-4 IOX thru IOX2411.................................................................4-11 J250AWK thru J250S...........................................................7-56 JD250S ................................................................................7-56 JDA261501 thru JDA262506 ...............................................9-26
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
JDA36150 thru JDA36250................................................... 9-26 JDF36000F25...................................................................... 7-23 JDL26150(C) thru JDL36250(C).......................................... 7-22 JDL36150T thru JDL36250T ............................................... 7-23 JGA26000S171 and JGA26000S256.................................. 9-26 JGA261501 thru JGA262506 .............................................. 9-26 JGA36000S17 and JGA36000S25...................................... 9-26 JGA36150 thru JGA36250 .................................................. 9-26 JGF36000F25...................................................................... 7-23 JGL26000S17 and JGL26000S25....................................... 7-33 JGL26150(C) thru JGL36250(C) ......................................... 7-22 JGL36000S17 and JGL36000S25....................................... 7-33 JGL36150T thru JGL36250T............................................... 7-23 JGL37100D81 thru JGL37250D82 ...................................... 7-34 JJA261501 thru JJA262506 ................................................ 9-26 JJA36150 thru JJA36250 .................................................... 9-26 JJF36000F25....................................................................... 7-23 JJL26150(C) thru JJL36250(C) ........................................... 7-22 JJL36150T thru JJL36250T................................................. 7-23 JJL36250M75 ...................................................................... 7-28 JLA26000S251 thru JLA26000S256 ................................... 9-26 JLA261501 thru JLA262506 ................................................ 9-26 JLA36000S17 and JLA36000S25 ....................................... 9-26 JLA36150 thru JLA36250 .................................................... 9-26 JLF36000F25 ...................................................................... 7-23 JLL26000S17 and JLL26000S25 ........................................ 7-33 JLL26150(C) thru JLL36250(C)........................................... 7-22 JLL36000S17 and JLL36000S25 ........................................ 7-33 JLL36150T thru JLL36250T ................................................ 7-23 JLL36250M75...................................................................... 7-33 JT3150 thru JT3250 ............................................................ 7-23 KA225DS thru KA225S ....................................................... 7-58 KA250RWB and KA250SWB .............................................. 7-56 KAC1BZ thru KAG2XZ .......................................................... 8-4 KBD1PZ thru KBF3PZ........................................................... 8-4 KCC1LZ thru KCG2YZ .......................................................... 8-4 KDD1PZ thru KDF3PZ .......................................................... 8-4 KFP...................................................................................... 1-13 KHL26000M and KHL36000M............................................. 7-33 KHL3612517DC thru KHL3625025DC ................................ 7-34 KI26200AB thru KI26250BC................................................ 9-27 KI36200 thru KI36250.......................................................... 9-27 KIL26110 thru KIL26250...................................................... 7-50 KIL36110 thru KIL36250...................................................... 7-50 KZ100 thru KZ103 ................................................................. 8-5 KZ13 thru KZ16 ..................................................................... 8-5 KZ32 ............................................................................... 8-2, 8-5 KZ62 thru KZ67 ..................................................................... 8-4 KZ74 thru KZ83 ..................................................................... 8-5 L100WDR2M4 thru L100WS2M3 ...................................... 21-33 L111N thru L221N ................................................................. 3-2 L300WDR2M4 thru L525WDR2M59 ................................. 21-33 LA1DX20 thru LA1DZ40........................................... 18-8, 23-15 LA1KN02 thru LA1KN407....................................... 18-27, 23-19 LA1SK02 thru LA1SK20 .................................................... 23-20 LA26125AB thru LA26400BC.............................................. 9-28 LA2KT2E and LA2KT2U......................................... 18-27, 23-19 LA34200MC thru LA34400MC ............................................ 9-28 LA36125 thru LA36400........................................................ 9-28 LA400AWK thru LA400S ..................................................... 7-56 LA4DA2E thru LA4DE3U..................................................... 18-9 LA4DFB thru LA4DWB ...................................................... 18-10 LA4DMK ............................................................................ 23-17 LA4DT0U thru LA4DT4U................................................... 23-17 LA4KA1U thru LA4KE1UG ..................................... 18-27, 23-19 LA4SKEIE and LA4SKEIU ................................................ 23-20 LA5D115450 thru LA5D150803 ........................................ 18-11 LA5F115450 thru LA5FH441............................................. 18-13 LA6DK10 ........................................................................... 23-16 LA6DK20B thru LA6DK20S................................................. 18-8 LA7D03B thru LA7D03Q ................................................... 18-16 LA7D1064 thru LA7D3064 ................................................ 18-16 LA7D901 thru LA7D903 .................................................... 18-16
2009 Schneider Electric All Rights Reserved
LA7F401 thru LA7F902 ..................................................... 18-16 LA7K0064 ......................................................................... 18-27 LA8D324 ........................................................................... 18-36 LA9CA06DT thru LA9CA16WT ......................................... 18-23 LA9D09966 thru LA9D80978 ................................. 18-1118-14 LA9D90 .................................................................. 18-27, 23-19 LA9D901 ........................................................................... 23-17 LA9D92 and LA9D93 ........................................................ 18-11 LA9D941 ........................................................................... 18-10 LA9E01 and LA9E02......................................................... 18-27 LA9F103............................................................................ 18-12 LA9F15076 thru LA9F15082 ............................................. 18-15 LA9F701 thru LA9FF4F ......................................... 18-1218-16 LA9F702 and LA9F703 ..................................................... 26-17 LA9FF601 and LA9FF602................................................. 18-11 LA9FF970 thru LA9FF982 ....................................... 18-7, 18-15 LA9FG4F and LA9FG4G .................................................... 18-5 LA9FG601 and LA9FG602 ............................................... 18-11 LA9FG970 thru LA9FG982 ...................................... 18-7, 18-15 LA9FH4F thru LA9FH4H ................................................... 18-15 LA9FH601 and LA9FH602 ................................................ 18-11 LA9FH976 thru LA9FH982....................................... 18-7, 18-15 LA9FJ4F thru LA9FJ4J ..................................................... 18-15 LA9FJ970 thru LA9FJ982 ........................................ 18-7, 18-15 LA9FK4F thru LA9FK4K ................................................... 18-15 LA9FK601 and LA9FK602 ................................................ 18-11 LA9FK976 thru LA9FK982 ....................................... 18-7, 18-15 LA9FL4F thru LA9FL4L..................................................... 18-15 LA9FL601 and LA9FL602 ................................................. 18-11 LA9FL970 thru LA9FL982 ........................................ 18-7, 18-15 LA9FX970 ......................................................................... 18-15 LA9K0969 and LA9K0970................................................. 18-27 LA9RM201 ........................................................................ 23-33 LA9TFD25 thru LA9TFD80 ............................................... 18-23 LAD21 and LAD22 ............................................................ 23-17 LAD31 and LAD32 ................................................. 18-37, 18-38 LAD311 thru LAD351 ............................................. 18-37, 18-38 LAD3B ............................................................................... 18-38 LAD4BB thru LAD4BBVU ............................. 18-9, 18-10, 23-17 LAD4CM............................................................................ 18-14 LAD4D3U thru LAD4RC3U ................................................. 18-9 LAD4RCE thru LAD4RCU........................................ 18-9, 23-16 LAD4T3B thru LAD4T3U..................................................... 18-9 LAD4TB and LAD4TS .............................................. 18-9, 23-16 LAD4V3E thru LAD4V3U .................................................... 18-9 LAD4VE thru LAD4VU ............................................. 18-9, 23-16 LAD6K10B thru LAD6K10S ..................................... 18-8, 23-16 LAD703B thru LAD703Q ................................................... 18-16 LAD7305 ........................................................................... 18-16 LAD7B10 thru LAD7B106 ................................................. 18-16 LAD7C1 and LAD7C2 ....................................................... 18-16 LAD7X3 ............................................................................. 18-11 LAD8N02........................................................................... 23-15 LAD8N11....................................................... 18-8, 23-15, 26-16 LAD8N20.................................................................. 18-8, 23-15 LAD90 ............................................................................... 18-11 LAD92560 and LAD96560 ................................................ 18-11 LAD96570 ......................................................................... 18-34 LAD9ET1........................................................................... 23-17 LAD9P3 thru LAD9P33 ..................................................... 18-11 LAD9R1 and LAD9R1V..................................................... 18-14 LADC22........................................................... 18-7, 18-8, 23-15 LADC223........................................................................... 23-15 LADLVRT24V thru LADLVRT208V ................................... 18-10 LADN01...................................................................... 18-7, 18-8 LADN02 thru LADN40 ..................................... 18-7, 18-8, 23-15 LADN023 thru LADN403 ................................................... 23-15 LADR0 thru LADT4 .................................................. 18-8, 23-16 LADR03 thru LADT43 ....................................................... 23-16 LADT9R1 and LADT9R1V ................................................ 18-14 LAL26125 thru LAL26400 ................................................... 7-51 LAL34200MC thru LAL34400MC ........................................ 7-35 LAL36125 thru LAL36400 ................................................... 7-51
i-25
ALPHA-NUMERIC LISTING
LAL3640022M thru LAL3640036M...................................... 7-30 LC1D09 thru LC1DT80A ...............................18-4, 18-11, 18-46 LC1F115 thru LC1F800.............................................. 18-518-7 LC1K0601 and LC1K0610................................................. 18-24 LC1K09004 and LC1K09008............................................. 18-26 LC1K0901 and LC1K0910................................................. 18-24 LC1K12004 ....................................................................... 18-26 LC1K1201 and LC1K1210................................................. 18-24 LC26300AB thru LC26600BC ............................................. 9-28 LC2D09 thru LC2DT40........................................................ 18-6 LC2K0601 thru LC2K1210 ..................................... 18-25, 18-26 LC36300 thru LC36600 ....................................................... 9-28 LCL26300 thru LCL26600 ................................................... 7-51 LCL36300 thru LCL36600 ................................................... 7-51 LDB101 thru LDB8TF .......................................................... 13-2 LDRB410F thru LDRB8WH ................................................. 13-3 LE1D093A62 thru LE2D803A72............................. 18-21, 18-22 LE36100LI thru LE36600LSG ............................................. 9-29 LE4CT2 thru LE25CT2 ........................................................ 7-53 LEL36100LI thru LEL36600LSG ......................................... 7-52 LH26125AB thru LH26400BC ............................................. 9-28 LH34200MC thru LH34400MC ............................................ 9-28 LH36125 thru LH36400 ....................................................... 9-28 LHL26000M ......................................................................... 7-33 LHL26125 thru LHL26400 ................................................... 7-51 LHL34200MC thru LHL34400MC ........................................ 7-35 LHL36000M ......................................................................... 7-33 LHL36125 thru LHL36400 ................................................... 7-51 LHL3625025DC thru LHL3640030DC................................. 7-34 LI26300AB thru LI26600BC................................................. 9-28 LI36300 thru LI36600 .......................................................... 9-28 LIL26300 thru LIL26600 ...................................................... 7-51 LIL36300 thru LIL36600 ...................................................... 7-51 LJB12606 thru LJB8X.......................................................... 13-3 LK3AD30 ............................................................................... 8-8 LK3AP63 and LK3AP83 ........................................................ 8-8 LK3LK4DU3........................................................................... 8-6 LK3SU3 thru LK4QU3 ........................................................... 8-6 LK70AN thru LK225AN........................................................ 1-13 LP1K0601 thru LP5K1210...................................... 18-2418-26 LR2D3561 and LR2D3563 .................................................. 18-4 LR2K0301 thru LR2K0321 ................................................ 18-24 LR3D01 thru LR3D3563 ...................................................... 18-4 LR9D5367 thru LR9F7581 .................................................. 18-5 LRD01 thru LRD4369 .......................................................... 18-4 LS1D30 thru LS1D323 ...................................................... 18-36 LSDL .......................................................................... 1-12, 1-13 LT6CT1001 thru LT6CT8001 ............................................ 16-95 LTM9CE180T .................................................................... 16-96 LTMCC004 ........................................................................ 16-96 LTMCU ................................................................... 16-9216-94 LTMEV40BD and LTMEV40FM ............................. 16-9216-94 LTMR...................................................................... 16-9216-94 LTMR08CBD thru LTMR27PFM............................. 16-9216-94 LU2B12 and LU2B32......................................................... 18-30 LU3R10 ............................................................................. 16-96 LU9AP00 thru LU9AP12.................................................... 18-31 LU9GC3............................................................................. 26-17 LU9SP0 ............................................................................. 18-30 LUA1C11 and LUA1C20 ........................................ 16-11, 18-28 LUA4F11 thru LUA8E20.................................................... 18-31 LUALB1 and LUALF1 ........................................................ 18-30 LUB12 and LUB32.................................................. 18-28, 18-32 LUB32NR .......................................................................... 16-11 LUCA05B thru LUCA05FU ..................................... 18-28, 18-30 LUCA05B thru LUCDX6FU .........................16-11, 18-28, 18-30 LUCA05BL thru LUCM32BL.............................................. 18-32 LUCM05BL thru LUCMX6BL............................................. 18-30 LUFC00 ............................................................................. 18-30 LUFDA10 and LUFDH20................................................... 18-30 LUFN02 thru LUFN20............................................. 16-11, 18-28 LUFP1 thru LUFP9 ............................................................ 26-17 LUFV2 ............................................................................... 18-30
i-26
LUFW10 .............................................................................18-30 LULC033 thru LULC15.......................................................18-31 LUR03 ................................................................................16-96 LUS12 and LUS32 .............................................................18-32 LUS32NR ...........................................................................16-11 LX1D2B5 thru LX1D4Z7 ....................................................18-17 LX1D6B5 thru LX1D8W7 ...................................................18-18 LX1FF thru LX1FX .............................................................18-18 LX36100 thru LX36600G .....................................................9-29 LX40TS thru LX62TS ...........................................................9-16 LX4D2BD thru LX4D8UD...................................................18-19 LX4F8 thru LX4FX .............................................................18-20 LX600AWK...........................................................................7-56 LX9FF thru LX9FL.................................................. 18-18, 18-20 LXD1B7 thru LXD1Z7 ........................................................18-17 LXD3B7 thru LXD3YC7......................................................18-18 LXI36100 thru LXI36600G ...................................................9-29 LXIL36100 thru LXIL36600 ..................................................7-52 LXIL36100G thru LXIL36600G.............................................7-52 LXL36100 thru LXL36600 ....................................................7-52 LXL36100G thru LXL36600G...............................................7-52 M32515 and M32549 ...........................................................7-42 M5IAI and M5IAI50 ..............................................................15-6 M800AWK thru M800S .............................................. 7-56, 7-58 M9PAF .................................................................................7-20 MA1200S .............................................................................7-56 MA1IBA12 thru MA8IMA90LL ................................................6-3 MAL36600 thru MAL361000 ................................................7-30 MAL3660040M thru MAL3680045M ....................................7-31 MCC2IMA12C thru MCC8IMA24C.........................................6-4 MCM8364.............................................................................4-16 MCS025 ..................................................................... 4-26, 4-27 MCT12B thru MCT14BC ......................................................15-6 MCT4RC ..............................................................................15-6 MCTBP.................................................................................15-6 MCTCT.................................................................................15-6 MCTS95135 .........................................................................15-6 MD330MI4 thru MD560MI9....................................................3-8 MD4100MI5 thru MD5100MI9................................................3-8 ME330P4W thru ME560P9W.................................................3-8 ME4100P5W thru ME5100P9W.............................................3-8 MES114 thru MET1482........................................................4-26 MG10285 thru MG10287 .....................................................7-20 MG17402 thru MG17474 .....................................................7-19 MG24110 thru MG24562 ............................................. 6-5, 7-19 MG26925 thru MG27150 .....................................................7-20 MGA263002 thru MGA268005.............................................9-29 MGA36300 thru MGA36800.................................................9-29 MGL26300 thru MGL26800 .................................................7-25 MGL36300 thru MGL36800 .................................................7-25 MGN26380 and MGN26381 ................................................7-20 MGN61300 thru MGN61431 ................................................7-17 MGN61500 thru MGN61537 ................................................7-18 MH26 and MH86WP ...................................... 9-6, 9-7, 9-9, 9-13 MH50......................................................................................1-5 MH62......................................................................................1-6 MHL26000M thru MHL260008M..........................................7-33 MHL36000M thru MHL360008M..........................................7-33 MHL3645031DC thru MHL36120040DC .............................7-34 MHT2DH20 ..........................................................................9-14 MICROTUSEAL ......................................................... 7-44, 7-53 MJA263002 thru MJA268005...............................................9-29 MJA36300 thru MJA36800...................................................9-29 MJL26300 thru MJL26800 ...................................................7-25 MJL36300 thru MJL36800 ...................................................7-25 MM125MB..............................................................................2-6 MM200MB.................................................................... 2-6, 2-15 MMBLC ................................................................................2-15 MMHB ................................................................. 1-22, 2-6, 2-15 MMLK250 thru MMLK600 ............................................ 2-6, 2-15 MMLRK ...................................................................... 1-22, 2-15 MMS020...............................................................................4-27 MMSAMK .............................................................................2-15
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
MMSK2 and MMSK4 ............................................................. 2-6 MP12X11PEDEXT and MP12X8PEDEXT ............................ 2-6 MP22125 thru MP86200........................................................ 2-5 MP35X11PED thru MP43X8PED .......................................... 2-6 MPH22125 thru MPR86200 .................................................. 2-5 MPSF12 thru MPSF26 .......................................................... 2-6 MPX81542........................................................................... 9-16 MPZ10S40F thru MPZB7S40FSS.......................... 14-12, 14-13 MSA141...................................................................... 4-26, 4-27 MTMB .................................................................................. 7-53 MTX836 thru MTX866 ......................................................... 9-16 N100MFI.............................................................................. 9-13 N150MH ....................................................................... 9-5, 9-13 N250MJN250MKC............................................................... 9-13 N400M ................................................................................. 9-13 NC26F and NC50S................................................9-69-8, 9-13 NC26FHR and NC50SHR .....................................9-69-8, 9-13 NC50NQVF and NC50NQVS ................................................ 1-5 NC50VF thru NC62SHR........................................9-69-8, 9-13 NC62NQVF and NC62NQVS ................................................ 1-6 NC62VF thru NC86VSHR .....................................9-69-8, 9-13 NCTWIRING........................................................................ 7-44 NE51HRT120V thru NE51HRT380V............................... 19-116 NF1000 thru NFASBKG3 .................................................... 5-25 NF102OE............................................................................. 9-14 NF102S ............................................................................... 9-14 NF125FTL and NF125SFL .................................................. 9-14 NF204OE............................................................................. 9-14 NF204S ............................................................................... 9-14 NF250FTL thru NF250SFL.................................................. 9-14 NF400FTL and NF400SFL .................................................. 9-14 NF418L1 thru NF484L6C .................................................... 9-13 NF600SFBH thru NF600SFBJ ............................................ 9-14 NF8430L1C thru NF8442M2JDC ........................................ 9-16 NFALV1 thru NFALV6 ......................................................... 9-14 NFCUM1 thru NFCUM6 ...................................................... 9-14 NFCUV1 thru NFCUV6........................................................ 9-14 NFDP1120G3C thru NFDR277G3C .................................... 5-26 NFFP15 ............................................................................... 9-14 NFFPCG3 and NFSELG3 ................................................... 5-25 NFN1CU thru NFN6CU ....................................................... 9-14 NFNL1 thru NFNL4.............................................................. 9-14 NFSN06 thru NFSN50......................................................... 5-25 NJPAF ................................................................................. 7-38 NQ102OE .............................................................................. 9-9 NQ102S................................................................................. 9-9 NQ12RDE.............................................................................. 9-9 NQ18L1 and NQ18L1C .................................................. 9-6, 9-7 NQ18RDE.............................................................................. 9-9 NQ204OE .............................................................................. 9-9 NQ204S................................................................................. 9-9 NQ24RDE.............................................................................. 9-9 NQ30L1 thru NQ30L6C .................................................. 9-6, 9-7 NQ418L1 and NQ418L1C .............................................. 9-6, 9-7 NQ42L2 thru NQ42L6C .................................................. 9-6, 9-7 NQ430L1 thru NQ484L6C .............................................. 9-69-8 NQ6RDE................................................................................ 9-9 NQ72L2 and NQ72L2C .................................................. 9-6, 9-7 NQ820B1C and NQ830L2C ................................................ 9-16 NQ8430B1C thru NQ8442L2C ............................................ 9-16 NQ84L2 thru NQ84L6C .................................................. 9-6, 9-7 NQC20FWG and NQC30FWG............................................ 1-11 NQFP15................................................................................. 9-9 NQFTL2H thru NQFTL4L ...................................................... 9-9 NQMB2HJ thru NQMB4LA ............................................. 9-7, 9-8 NQN1CU thru NQN6CU ........................................................ 9-9 NQNL1 thru NQNL4 .............................................................. 9-9 NQSFB2HJ thru NQSFB4Q .................................................. 9-9 NQSFL1 thru NQSFL4 ................................................... 9-5, 9-9 NT08N1 ............................................................................... 11-6 NTX836 thru NTX866 .......................................................... 9-16 NW08H1 thru NW50L1........................................................ 11-6 OCIVF.................................................................................. 4-11
2009 Schneider Electric All Rights Reserved
OCK400 .............................................................................. 1-22 ORICA and ORICA5C ......................................................... 15-6 P1200AWK thru P1200S............................................ 7-56, 7-58 P751N and P753N .............................................................. 15-3 PAF361200DC thru PAF362000DC.................................... 7-34 PAK10C1 thru PAK1004CGFI ............................................ 1-25 PB100EC thru PB225WF .................................................... 12-2 PBCF3A100CR thru PBCF5A225TB .................................. 12-2 PBCP3A100ST048 thru PBCP5A225ST120 ...................... 12-2 PBFO100FA and PBFO100QO .......................................... 12-3 PBLA36300G thru PBLA36400GN ..................................... 12-9 PBLC34300G thru PBLC34600GN ................................... 12-10 PBLE36300GLI thru PBLE36600GNLSG ......................... 12-10 PBLH36300G thru PBLH36400GN ................................... 12-10 PBLI34300G thru PBLI36600GN ...................................... 12-10 PBLX36100G thru PBLX36400GN ................................... 12-10 PBLXI36300G thru PBLXI36600GN ................................. 12-10 PBP54100FA and PBP54100QO........................................ 12-3 PBPFA3A100 thru PBPFA5A100A100 ............................... 12-3 PBPIOCVR.......................................................................... 12-2 PBPQO3A100 thru PBPQO5A100...................................... 12-3 PBPQOR3A100 thru PBPQOR5A100M420B ..................... 12-3 PBPTB3A100 thru PBPTB5A100........................................ 12-3 PBQ3640G and PBQ3660G ............................................... 12-9 PBQ4060RMK..................................................................... 12-9 PBQ4640G and PBQ4660G ............................................... 12-9 PBRFLKIT ........................................................................... 12-3 PBTB306G and PBTB506G ................................................ 12-4 PCF260000M ...................................................................... 7-33 PCF360000M ...................................................................... 7-33 PCF362500DC .................................................................... 7-34 PCM4000 and PCM4000T .................................................. 4-11 PCS050D5CE305SC thru PCS300D5N16S ....................... 4-35 PCS101 ............................................................................... 5-25 PDC12DG4 ......................................................................... 7-40 PDC12P4 and PDC12P44 .................................................. 7-40 PDC3HD2 thru PDC6P204 ................................................. 7-40 PFA32015G thru PFA36100G ............................................ 12-9 PFA32015GN thru PFA34100GN ....................................... 12-9 PFCD4006 thru PFCDS4115 .............................................. 4-28 PFCD4006F thru PFCDS4115F.......................................... 4-29 PFH36015G thru PFH36100GN ....................................... 12-10 PFI34020G thru PFI34100GN........................................... 12-10 PGA36025(C)U31A thru PGA36080(C)U74AE1................. 9-30 PGA36100 thru PGA36120U74AE1 ................................... 9-30 PGL36025(C)U31A thru PGL36120(C)U74AE1 ................. 7-26 PGL36060 thru PGL36120.................................................. 7-26 PHD36015G thru PHD36150GN....................................... 12-11 PHF260000M ...................................................................... 7-33 PHF360000M ...................................................................... 7-33 PHG36015G thru PHL36150GN ....................................... 12-11 PIU2IMA16 thru PIU8IMA24 ............................................. 12-13 PIU2IMA16C thru PIU8IMA24C ............................................ 6-4 PJA26000S102 thru PJA26000S805 .................................. 9-30 PJA36000S10 thru PJA36000S80 ...................................... 9-30 PJA36025(C)U31A thru PJA36080(C)U74AE1................... 9-30 PJA36100 thru PJA36120U74AE1 ..................................... 9-30 PJD36175G thru PJJ36250GN ......................................... 12-11 PJL26000S10 thru PJL26000S80 ....................................... 7-33 PJL36000S10 thru PJL36000S80 ....................................... 7-33 PJL36025(C)U31A thru PJL36120(C)U74AE1 ................... 7-26 PJL36060 thru PJL36120.................................................... 7-26 PJL36060M68 thru PJL36120M70...................................... 7-30 PJL36175G thru PJL36250GN ......................................... 12-11 PK15GTAL thru PK23GTAL....................... 1-13, 1-16, 9-9, 9-14 PK27GTA ............................................................ 9-9, 9-14, 9-23 PK27GTACU ................................................................ 9-9, 9-14 PK2MB and PK3MB ............................................................ 1-12 PK2SCPV............................................................................ 1-22 PK32DGTA ......................................................................... 9-23 PK3GTA thru PK27GTA............................................... 1-51-16 PK3GTA1 .............................................................. 1-5, 1-15, 3-3 PK49SP............................................................... 1-22, 3-12, 9-9
i-27
ALPHA-NUMERIC LISTING
PK4DTIM4HA thru PK4DTIM4LAL........................................ 1-9 PK4FL thru PK8FL .............................................................. 1-13 PK4MB2HA and PK4MB2LA............................................... 1-12 PK5RK................................................................................. 1-12 PK7GTA .......................................................1-5, 1-9, 1-15, 5-18 PKA36025(C)U31A thru PKA36080(C)U74AE1.................. 9-30 PKA36100 thru PKA36120U74AE1..................................... 9-30 PKGTAB .....................................................1-13, 5-18, 9-9, 9-14 PKHB................................................................................... 1-24 PKI34125G thru PKI34250GN........................................... 12-10 PKL26000S10 thru PKL26000S80 ...................................... 7-33 PKL36000S10 thru PKL36000S80 ...................................... 7-33 PKL36025(C)U31A thru PKL36120(C)U74AE1 .................. 7-26 PKL36060 thru PKL36120................................................... 7-26 PKOGTA2...................................................3-3, 3-12, 3-19, 7-58 PKOGTA3.............................................................................. 3-3 PKOGTA4............................................................................ 7-58 PKOGTA7 and PKOGTA8................................................... 3-12 PKOGTC2 and PKOGTC3 .................................................. 3-12 PKOGTJ250 ........................................................................ 7-58 PLA36025(C)U31A thru PLA36080(C)U74AE1 .................. 9-30 PLA36100 thru PLA36120U74AE1 ..................................... 9-30 PLESH163155 thru PLESNS36005 .................................... 4-11 PLL24000S10 thru PLL24000S80....................................... 7-33 PLL34000S10 thru PLL34000S80....................................... 7-33 PLL34060M68 thru PLL34120M70...................................... 7-30 PLL36025(C)U31A thru PLL36120(C)U74AE1 ................... 7-26 PLL36060 thru PLL36120 ................................................... 7-26 PLVENGUS ........................................................................... 4-5 PM710 thru PM8MA ............................................................ 4-10 PQ3203G thru PQ4620G .................................................... 12-9 PS080.................................................................................. 4-11 PS24.................................................................................... 4-15 PS3220G thru PS4620G ..................................................... 12-9 PSDS................................................................................... 1-12 PTB302G thru PTB516GV ......................................... 12-4, 12-5 PTMA36100GH thru PTQ4680GV ........................... 12-9, 12-10 PTRG36060GHU31A thru PTRL36160GNVU44A ............ 12-12 PTT23WG thru PTT44WG .................................................. 12-4 Q1100AN...................................................................... 9-9, 9-14 Q1150AN............................................................................... 9-9 Q22200NRB thru Q23225NRB..........................1-24, 7-56, 7-58 Q22200NS.........................................................1-24, 7-56, 7-58 Q23225NF .................................................................. 7-56, 7-58 Q23225NFS and Q23225NFS............................................. 1-24 Q23225NRB and Q23225NS ..................................... 7-56, 7-58 Q2FP ................................................................................... 1-13 Q4L2250 thru Q4L3400....................................................... 7-50 QBA220701 thru QBA322256 ............................................. 9-25 QBL22000S22 ..................................................................... 7-33 QBL22070 thru QBL32250 ......................................... 1-24, 7-24 QBL32000S22 ..................................................................... 7-33 QBMIK ................................................................................. 7-38 QBP22070TM thru QBP22225TM................................ 2-6, 2-15 QBP32070TM thru QBP32225TM....................................... 2-15 QBPA and QBPAF .............................................................. 7-38 QC12L200C and QC12L200CH .......................................... 1-19 QC2442M150CH thru QC2442M200CH ............................. 1-20 QC816F100CH thru QC816F200CH................................... 1-19 QCGK3 ................................................................................ 1-22 QDA220701 thru QDA322256............................................. 9-25 QDL22070 thru QDL22250................................1-22, 1-24, 7-24 QDL32070 thru QDL32250..................................1-8, 1-24, 7-24 QDP22070TM thru QDP22225TM ............................... 2-6, 2-15 QDP32070TM thru QDP32225TM ...................................... 2-15 QGA220701 thru QGA322256 ............................................ 9-25 QGL22070 thru QGL22250 ........................................ 1-24, 7-24 QGL32070 thru QGL32250 .................................1-8, 1-24, 7-24 QGP22070TM thru QGP22225TM ............................... 2-6, 2-15 QGP32070TM thru QGP32225TM ...................................... 2-15 QH115 thru QH330....................................................... 1-2, 7-10 QHB115 thru QHB330......................................................... 9-10 QJA220701 thru QJA322256 .............................................. 9-25
i-28
QJL22070 thru QJL22250.......................................... 1-24, 7-24 QJL32070 thru QJL32250................................... 1-8, 1-24, 7-24 QJP22070TM thru QJP22225TM................................. 2-6, 2-15 QJP32070TM thru QJP32225TM.........................................2-15 QMB100R ............................................................................9-34 QMB1IMA12C thru QMB8IMA24C.........................................6-4 QMB200EK1 and QMB200EK2 ...........................................9-34 QMB221HW thru QMB264W ...............................................9-34 QMB300EK1 and QMB300EK2 ...........................................9-34 QMB30R ..............................................................................12-9 QMB321HW thru QMB367W ...............................................9-34 QMB36R .................................................................... 9-34, 12-9 QMB4060R ................................................................ 9-34, 12-9 QMB600T6...........................................................................9-34 QMB60R .................................................................... 9-34, 12-9 QMB60RQMB36R................................................................9-34 QMB610EK1 and QMB610EK2 ...........................................9-34 QMB800T6...........................................................................9-34 QMJ361T thru QMJ364T .....................................................9-34 QMJ365 and QMJ366 ..........................................................9-34 QO110 thru QO170............................................. 1-2, 1-22, 7-10 QO110K thru QO130K ................................................. 1-3, 7-11 QO11220M100C thru QO13040M200C...............................1-10 QO11224L125GC and QO13040L200GC ...........................1-10 QO11224L125WG thru QO13040L200WG .........................1-11 QO112L125G thru QO142L225G ..........................................1-5 QO112L125GC and QO120L125GC ...................................1-10 QO112L125GRB thru QO148L125GRB ................................1-7 QO112M100 thru QO142M225..............................................1-6 QO112M100C thru QO140M200C.......................................1-10 QO112M100RB thru QO142M225RB....................................1-7 QO11428MX150FTRB and QO11428MX200FTRB ..............1-9 QO11428UX200FTRB ...........................................................1-9 QO115CAFI and QO120CAFI...................................... 1-3, 7-11 QO115EPD thru QO260EPD ....................................... 1-3, 7-11 QO115GFI thru QO260GFI.......................................... 1-3, 7-11 QO115HID thru QO330HID ......................................... 1-3, 7-11 QO115HM and QO120HM........................................... 1-3, 7-11 QO115VH thru QO130VH................................... 1-2, 1-22, 7-10 QO115VHCAFI and QO120VHCAFI............................ 1-3, 7-11 QO115VHGFI thru QO130VHGFI................................ 1-3, 7-11 QO12436L200TFT .................................................................1-5 QO12436M200TFT ................................................................1-6 QO130L150TC.....................................................................1-10 QO13842MX150 thru QO13842MX225 .................................1-9 QO13842UX225.....................................................................1-9 QO1515 thru QO3020.................................................. 1-2, 7-10 QO1612M125FTRB ...............................................................1-7 QO1816M150FTRB and QO1816M200FTRB .......................1-7 QO1DM10020TRBR thru QO1DM10050TRBR .....................1-9 QO1HPL....................................................................... 1-4, 7-12 QO1HT.................................................................. 1-4, 7-12, 9-9 QO1LO......................................................................... 1-4, 1-14 QO1PA.................................................................. 1-4, 7-12, 9-9 QO1PAF................................................................ 1-4, 7-12, 9-9 QO1PL .................................................................. 1-4, 7-12, 9-9 QO1SE.................................................................................1-12 QO200 and QO2000 .................................................... 1-3, 7-11 QO2000NRB and QO2000NS ..................................... 1-24, 3-2 QO200TR..................................................................... 1-24, 3-2 QO200TRNM .......................................................................1-24 QO20303020................................................................ 1-2, 7-10 QO210 thru QO2200.................................... 1-2, 2-6, 2-15, 7-10 QO2100BNRB and QO3100BNRB ......................................1-24 QO210SWN thru QO350SWN ..................................... 1-3, 7-11 QO2125SL and QO2225SL ......................................... 1-4, 7-12 QO215H thru QO2100H............................................... 1-2, 7-10 QO215VH thru QO2200VH.................1-2, 1-22, 2-6, 2-15, 7-10 QO2175SB................................................................... 1-12, 6-8 QO24L50TTS.......................................................................1-10 QO24L60NRNM.....................................................................1-7 QO24L70RB...........................................................................1-7 QO24L70TS .........................................................................1-10
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
QO260NATR and QO260NATS ................................... 1-24, 3-2 QO2DTI and QO2DTIM.........................................1-4, 1-9, 7-12 QO2L30S............................................................................... 1-5 QO2L30TTS ........................................................................ 1-10 QO2L40RB ............................................................................ 1-7 QO2PAF ................................................................1-4, 7-12, 9-9 QO2TR ................................................................................ 1-24 QO300 and QO3000 .................................................... 1-3, 7-11 QO310 thru QO3100 .................................................... 1-2, 7-10 QO310SWN thru QO350SWN ..................................... 1-3, 7-11 QO3125SL.................................................................... 1-4, 7-12 QO312L125G thru QO342L225G.......................................... 1-8 QO312L125GRB thru QO342L225GRB................................ 1-8 QO315VH thru QO3100VH .................................1-2, 1-22, 7-10 QO327M100 .......................................................................... 1-8 QO327M100RB ..................................................................... 1-8 QO330MQ125 thru QO342MQ225........................................ 1-8 QO330MQ125RB thru QO342MQ225RB.............................. 1-8 QO3HT ......................................................................... 7-12, 9-9 QO403L60NRB ..................................................................... 1-8 QO48M30DSGP and QO48M60DSGP ................................. 1-9 QO60SL........................................................................ 1-4, 7-12 QO612L100RB and QO612L100RBCU ................................ 1-7 QO612L100TRB.................................................................... 1-7 QO70AN ....................................................................... 9-9, 9-14 QO816L100RB and QO816L100RBCU ................................ 1-7 QOB110 thru QOB170 ........................................................ 9-10 QOB110K thru QOB130K.................................................... 9-10 QOB115CAFI and QOB120CAFI ........................................ 9-10 QOB115EPD thru QOB260EPD.......................................... 9-10 QOB115GFI thru QOB260GFI ............................................ 9-10 QOB115HID thru QOB330HID ............................................ 9-10 QOB115HM and QOB120HM ............................................. 9-10 QOB115VH thru QOB130VH .............................................. 9-10 QOB115VHCAFI and QOB120VHCAFI .............................. 9-10 QOB115VHGFI thru QOB130VHGFI .................................. 9-10 QOB200 and QOB2000....................................................... 9-10 QOB210 thru QOB2125 ...................................................... 9-10 QOB210SWN thru QOB250SWN........................................ 9-10 QOB2125SL .......................................................................... 9-9 QOB215H thru QOB2100H ................................................. 9-10 QOB215VH thru QOB2150VH ............................................ 9-10 QOB300 and QOB3000....................................................... 9-10 QOB310 thru QOB3100 ...................................................... 9-10 QOB310SWN thru QOB350SWN........................................ 9-10 QOB3125SL .......................................................................... 9-9 QOB315VH thru QOB3150VH ............................................ 9-10 QOC12UF thru QOC42UF ......................................1-5, 1-6, 1-8 QOC12US thru QOC42US ......................................1-5, 1-6, 1-8 QOC20U100F and QOC20U100S ........................................ 1-6 QOC20UFWG and QOC30UFWG ...................................... 1-11 QOC342MQF and QOC342MQS .......................................... 1-8 QOC38MXUF ........................................................................ 1-9 QOCGK2 ............................................................................... 1-9 QOCRBGK1 .......................................................................... 1-9 QOE250GFINM ................................................................... 1-24 QOFP ................................................................1-13, 1-22, 2-15 QOGFI1PAF and QOGFI2PAF .............................1-4, 7-12, 9-9 QOGL20 .............................................................................. 1-10 QOH240 thru QOH2125 ...............................1-2, 2-6, 2-15, 7-10 QOHPL ......................................................................... 1-4, 7-12 QOL125 and QOL225 .................................................. 1-6, 1-16 QOL3125 and QOL3225 ....................................................... 1-8 QOM1FP and QOM2FP ...................................................... 1-13 QOM1PA and QOM2PA............................................. 1-13, 1-14 QOM2100MM thru QOM2200MM ......................................... 2-6 QOM2100MVH thru QOM2200MVH ..................................... 2-6 QOM2100VH thru QOM2225VH ..................1-5, 1-16, 1-22, 2-6 QOM22225NRB .................................................................. 1-24 QOM50VH thru QOM2225VH .............................1-5, 1-16, 1-22 QOMB1 thru QOMB3 .......................................................... 7-13 QON11224L125I thru QON12024L125I .............................. 7-13 QON112L125I thru QON142L225I ...................................... 7-13
2009 Schneider Electric All Rights Reserved
QON124L200DL ................................................................. 7-13 QON12L100 thru QON12L200FTL ..................................... 7-13 QON24L70 .......................................................................... 7-13 QON2L40 and QON2L70 .................................................... 7-13 QON312L125 thru QON342L225I....................................... 7-13 QON3B................................................................................ 7-13 QON403L60N ..................................................................... 7-13 QON612L100 ...................................................................... 7-13 QON816L100 ...................................................................... 7-13 QONQ30LS400 and QONQ42LS400 ............................ 1-5, 1-6 QORBGK2 ............................................................................ 1-9 QOSAMK ..................................................................... 1-12, 6-7 QOT1515 thru QOT2020 ............................................. 1-2, 7-10 QOTHPA ...................................................................... 1-4, 7-12 QOTHT......................................................................... 1-4, 7-12 QOU110 thru QOU3100...................................................... 7-14 QOU115HM and QOU120HM............................................. 7-14 QOU115VH thru QOU330VH.............................................. 7-14 QOU14100BAFB thru QOU16150JBAF ............................. 7-15 QOU1CMSB........................................................................ 7-15 QOU1PA ............................................................................. 7-15 QOU1PAFLA....................................................................... 7-15 QOU1PL.............................................................................. 7-15 QOU200 .............................................................................. 7-14 QOU2000 ............................................................................ 7-14 QOU20001 .......................................................................... 7-14 QOU215H thru QOU230H .................................................. 7-14 QOU2DTILA ........................................................................ 7-15 QOU2PAFLA....................................................................... 7-15 QOU300 .............................................................................. 7-14 QOU3000 ............................................................................ 7-14 QOU30001 .......................................................................... 7-14 QOUCP2 thru QOUCP6B ................................................... 7-15 QOUEC and QOUECB ....................................................... 7-15 QOUFR and QOUFRB ........................................................ 7-15 QOUHFSC1 and QOUHFSC1B .......................................... 7-15 QOULFSC1 and QOULFSC1B ........................................... 7-15 QOUMF1 thru QOUMFS1B ................................................ 7-15 QOURT and QOURTB ........................................................ 7-15 QOVP1 thru QOVP10 ......................................................... 1-11 QU12L400CL thru QU12L400SL ........................................ 1-21 QU816D400CK thru QU816D400SL................................... 1-21 QUM400CK and QUM400CL .............................................. 1-21 QYU110 thru QYU130 ........................................................ 7-14 R400L.................................................................................. 1-22 R417A thru R826A .............................................................. 7-46 RA1 thru RA1WM................................................................ 15-6 RC12L200C and RC12L200CH .......................................... 1-19 RC1624M100S and RC1624M125S ................................... 1-20 RC200S............................................................................... 1-19 RC2040M125CH thru RC2040M200CH ............................. 1-20 RC2040M200C ................................................................... 1-20 RC26546829 thru RC26546831........................................ 23-36 RC2M200S and RC2M200SH ............................................ 1-19 RC816D200CH ................................................................... 1-19 RC816F100CH thru RC816F200CH ................................... 1-19 RC816F150C and RC816F200C ........................................ 1-19 RC87610050 thru RC87610440........................................ 23-36 RC8L125S........................................................................... 1-19 RCGK2 ................................................................................ 1-22 RCP0624 thru RCP3024 ..................................................... 13-5 RDB102 thru RDB126 ......................................................... 13-3 RDB41 thru RDB86 ............................................................. 13-3 RE11LAMW thru RE11RMXMU........................................ 23-24 RE48ACV12MW thru RE48ATM12MW ............................ 23-24 RE7CL11BU thru RE7TP13BU .............................. 23-25, 23-26 RE8CL11BUTQ thru RE8TA61BUTQ ............................... 23-27 RE9RA11MW7 thru RE9TA51MW.................................... 23-27 REC06 thru REC30 ............................................................. 13-6 REXL2TMB7 thru REXL4TMP7 ........................................ 23-24 RFK03 ........................................................... 3-19, 8-16, 16-124 RFK03H ....................................................................... 3-2, 3-11 RFK03L ............................................................................... 3-11
i-29
ALPHA-NUMERIC LISTING
RFK06 and RFK06H..................... 3-7, 3-11, 3-19, 8-16, 16-124 RFK10 ................................................ 3-2, 3-7, 3-11, 3-19, 8-16 RFK26000S25 thru RKF26000S20 ..................................... 7-33 RG50 ................................................................................... 13-6 RGA36100CU31A thru RGA36120CU74AE1 ..................... 9-27 RGF36060(C)U31A thru RGF36300(C)U74AE1................. 7-27 RGF36120 thru RGF36250 ................................................. 7-27 RHV062100009 thru RHV302100033 ................................. 13-6 RHZ66 ............................................................................... 26-16 RJA36100CU31A thru RJA36120CU74AE1 ....................... 9-27 RJF36060(C)U31A thru RJF36300(C)U74AE1................... 7-27 RJF36120 thru RJF36250 ................................................... 7-27 RKA36100CU31A thru RKA36120CU74AE1 ...................... 9-27 RKF36000S12 thru RKF36000S30 ..................................... 7-33 RKF36060(C)U31A thru RKF36300(C)U74AE1.................. 7-27 RKF36120 thru RKF36250 .................................................. 7-27 RL3TB and RL3TB4 ............................................................ 7-41 RLA36100CU31A thru RLA36120CU74AE1....................... 9-27 RLED ................................................................................... 15-6 RLF26000S12 thru RLF26000S20 ...................................... 7-33 RLF36000S12 thru RLF36000S20 ...................................... 7-33 RLF36060(C)U31A thru RLF36300(C)U74AE1 .................. 7-27 RLF36120 thru RLF36250................................................... 7-27 RLK26000S25 thru RLK36000S30...................................... 7-33 RLTB and RLTB4 ................................................................ 7-41 RM1204NI ........................................................................... 15-3 RM17JC00MW .................................................................. 23-30 RM17TA00 thru RM17TU00.............................................. 23-31 RM17UAS14 thru RM17UBE16 ........................................ 23-32 RM35ATL0MW thru RM35ATW5MW................................ 23-34 RM35BA10 ........................................................................ 23-33 RM35HZ21FM ................................................................... 23-34 RM35JA31MW and RM35JA32MW .................................. 23-30 RM35LM33MW and RM35LV14MW ................................. 23-33 RM35S0MW ...................................................................... 23-34 RM35TF30......................................................................... 23-31 RM35TM250MW ............................................................... 23-31 RM35TM50MW ................................................................. 23-31 RM35UA11MW thru RM35UB3N30 .................................. 23-32 RM504NI ............................................................................. 15-3 RM79696006 thru RM79696044 ....................................... 23-33 RMC1000G3120 thru RMC500G3277 ................................ 5-26 RMCA61BD thru RMCV60BD ........................................... 23-38 RMDI1204NI........................................................................ 15-3 RMDI504NI.......................................................................... 15-3 RMDR1204NI ...................................................................... 15-3 RMDR504NI ........................................................................ 15-3 RMPT10BD thru RMTK90BD ............................................ 23-38 RPF2AB7 thru RPF2BP7 .................................................... 23-7 RPM11B7 thru RPM43P7.................................................... 23-4 RPZ1DA thru RPZ4FA ........................................................ 23-5 RPZF1 thru RPZF4.............................................................. 23-4 RPZR235............................................................................. 23-5 RRC06 thru RRC30............................................................. 13-6 RRV182100012LR and RRV182100012RR........................ 13-6 RSB06 thru RSB30.............................................................. 13-6 RSB1A120B7 thru RSB2A080U7........................................ 23-8 RSC16G3120 thru RSC16G3277........................................ 5-25 RSG4................................................................................... 2-15 RSV062100120 thru RSV122100120.................................. 13-5 RSV122ET and RSV122ST................................................. 13-6 RSV182100120 ................................................................... 13-5 RSV182ET and RSV182ST................................................. 13-6 RSV242100120 and RSV302100120.................................. 13-5 RSZE1S35M thru RSZR215................................................ 23-8 RTV062100011 thru RTV302100035 .................................. 13-6 RU3040D400CK thru RU3040D400FL................................ 1-21 RUC60................................................................................. 13-6 RUMC2AB1B7 thru RUMC2AB3P7 .................................... 23-6 RUMC3AB1B7 thru RUMC3AB3P7 .................................... 23-6 RUMF2AB1B7 thru RUMF2AB3P7 ..................................... 23-6 RUMF3AB1B7 thru RUMF3AB3P7 ..................................... 23-6 RUW101MW thru RUW242P7 ................................... 23-5, 23-7
i-30
RUZ420 thru RUZSF3M.......................................................23-7 RVE06 thru RVE30 ..............................................................13-6 RWT06ACP thru RWT18XES .................................... 13-4, 13-5 RWTBG100..........................................................................13-5 RWTCDO .............................................................................13-5 RWTDCOV60.......................................................................13-5 RWTP60...............................................................................13-5 RWTRC................................................................................13-5 RXM021BN thru RXM041FU7 ................................... 23-3, 23-5 RXM2AB1B7 thru RXM2AB3P7TQ............................ 23-2, 23-3 RXM3AB1B7 thru RXM3AB2P7...........................................23-2 RXM4AB1B7 thru RXM4AB3BDTQ ........................... 23-2, 23-3 RXM4GB1B7 thru RXM4GB3P7..........................................23-2 RXV062100012 thru RXV302100036 ..................................13-6 RXZ400 ................................................................................23-3 RXZE2DA and RXZE2FA .......................................... 23-3, 23-5 RXZE2M114 thru RXZE2S114M .........................................23-3 RXZL420 and RXZL520.................................... 23-3, 23-5, 23-7 RXZR335 .............................................................................23-3 RXZS2..................................................................................23-3 RZ1011 thru RZ1031 ...........................................................7-46 RZ511 thru RZ535 ...............................................................7-46 RZD60..................................................................................13-6 RZM021BN thru RZM041FU7..............................................23-8 S131A thru S174A ...............................................................7-43 S29273 thru S29287 ............................................................7-42 S29305 thru S29329 ............................................................7-38 S29337 thru S29346 ............................................................7-37 S29354 thru S29371 ............................................................7-38 S29382 thru S29414 ............................................................7-36 S29433 thru S29440 ............................................................7-37 S29450 thru S29452 ............................................................7-36 S31540 thru S31548 ............................................................7-37 S32631.................................................................................7-38 S33033 thru S33038 ............................................................7-37 S33098 thru S33171 .................................................. 7-427-44 S33575 thru S33595 ............................................................7-44 S33646.................................................................................7-41 S33658 thru S33685 .................................................. 7-36, 7-37 S33717 and S33718 ............................................................7-38 S33763 thru S33788 ............................................................7-42 S33801.................................................................................7-36 S33852 thru S33859 ............................................................7-42 S33890.................................................................................7-38 S33928.................................................................................7-41 S33929.................................................................................7-38 S33930 and S33931 ............................................................9-23 S33932 thru S33935 ............................................................7-38 S33937.................................................................................7-44 S33996 and S33997 ............................................................7-38 S33998.................................................................................7-41 S34036.................................................................................7-44 S37420.................................................................................7-37 S37422.................................................................................7-38 S37423 and S37424 ............................................................7-39 S37425 thru S37430 ............................................................7-41 S37432 thru S37440 ............................................................7-38 S37442 and S37443 ............................................................7-42 S37444 thru S37450 ............................................................7-41 S44936 thru S46998 ............................................................7-38 S47067.................................................................................7-44 S47390 thru S47398 ............................................................7-37 S48182 thru S48896 ............................................................7-44 S48899.................................................................................7-42 S48907 thru S48916 ............................................................7-44 S48933.................................................................................7-42 S6200A0A0B0A0A0R thru S6200T1A0B0A0A0R .................4-8 S64201 thru S64273 ............................................................7-44 S7300A0B0B0A0A0A thru S8600C0C0H6A0A0A......... 4-7, 4-8 SA10BL and SA10LW..........................................................11-5 SA26PS and SA26PSR .......................................................11-5 SA7PL ..................................................................................11-5 SA8LL ..................................................................................11-5
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
SAIF200............................................................................... 4-11 SAM..................................................................................... 4-11 SASFB100L thru SASFB225R ............................................ 11-5 SASFB100LAB thru SASFB225RBC .................................. 11-5 SB124IR thru SB348WS ..................................................... 11-4 SBA15D13MS thru SBAD800R........................................... 11-5 SBSAD800 and SBSAD800R.............................................. 11-5 SC12L200F and SC12L200S .............................................. 1-19 SC1624M100F thru SC3040M225F .................................... 1-20 SC1624M100S thru SC3040M200S.................................... 1-20 SC200F ............................................................................... 1-22 SC2040M200C .................................................................... 1-20 SC2636M200FPV and SC2636M225FPV........................... 1-20 SC40M200S ........................................................................ 1-20 SC816D150C thru SC816F200S......................................... 1-19 SC8L125F and SC8L125S .................................................. 1-19 SCBRLLOCK....................................................................... 1-22 SD12781.............................................................................. 3-10 SDAG26 .............................................................................. 1-10 SDGT30020 thru SDGT300C300C ..................................... 1-10 SDM10BW thru SDMSA4P ................................................. 5-28 SDSA1175 and SDSA3650 ........................1-12, 6-7, 6-8, 16-70 SDSA1AC and SDSA2V........................................................ 6-8 SDSA4P and SDSA4P2VR ................................................... 6-8 SDSB1175C and SDSB1175R.............................................. 6-8 SF124FR thru SF348WS..................................................... 11-4 SFCF12 ............................................................................... 7-42 SFT080................................................................................ 4-26 SFT2841KIT ............................................................... 4-26, 4-27 SK9795 thru SK9948BW ..................................................... 7-13 SL100 thru SL800................................................................ 9-23 SLC12MSG thru SLC36SC ................................................. 5-18 SLC4CSF8 ................................................................. 5-18, 5-26 SLC5000CT2FSS thru SLC5000CTL2SS ............................. 5-7 SLC5000SDHG104 thru SLC5000SDSPU4........................ 5-20 SLC5030URC...................................................................... 5-10 SLC5031PE and SLC5031PEWP ....................................... 5-12 SLC5050CT2FBK and SLC5050CTL2WE ............................ 5-7 SLC5050IS1 thru SLC5054NRP9 ......................................... 5-4 SLC5055DLBK thru SLC5055DLWE..................................... 5-6 SLC5058NLCM thru SLC5058NRP9..................................... 5-4 SLC5070THBBK thru SLC5070THPWE ............................. 5-11 SLC5080CT2FBK thru SLC5080CTL2WE ............................ 5-7 SLC5080LC8 thru SLC5084NLWE ....................................... 5-5 SLC5084TX ......................................................................... 5-10 SLC5085DLBK thru SLC5085DLWE..................................... 5-6 SLC5086F30 thru SLC5086NLWE........................................ 5-5 SLC5088TX ......................................................................... 5-10 SLC5100BCS thru SLC5100TUS........................................ 5-17 SLC5101TD20..................................................................... 5-15 SLC5102BCLEDL................................................................ 5-13 SLC5102TD10..................................................................... 5-15 SLC5104BCL....................................................................... 5-13 SLC5104TD5....................................................................... 5-15 SLC5500CN thru SLC5502DAL .......................................... 5-17 SLC5504HRVF thru SLC5512TRVFP........................ 5-14, 5-15 SLC560011............................................................................ 5-9 SLC5600ICK thru SLC5600ODPWE................................... 5-10 SLC5600P243750T thru SLC560884T.................................. 5-9 SLC5750WPL thru SLC5753PEIRL .................................... 5-12 SLC60MFG thru SLC60MSG .............................................. 5-18 SLC8M................................................................................. 5-18 SLCE5504TGI and SLCLE5504AUX .................................. 5-13 SLCLE5504HAMP and SLCLE5504TAMP ......................... 5-15 SLCU5100TB ...................................................................... 5-15 SLCZ00004DT thru SLCZ082000TP................................... 5-19 SLSBCB thru SLSBCW ....................................................... 5-21 SLSCDS2000 thru SLSCUS2000........................................ 5-22 SLSDWD1277UB thru SLSDWS1277UW........................... 5-21 SLSPCW001 ....................................................................... 5-23 SLSPIP210 thru SLSPIPBRACKET .................................... 5-23 SLSPP1277 ......................................................................... 5-22 SLSPSP101 and SLSPSP102............................................. 5-23
2009 Schneider Electric All Rights Reserved
SLSPWD1277UB thru SLSPWS1277UW ........................... 5-21 SLSSP24............................................................................. 5-22 SLSUWD1277UB thru SLSUWS1277UW........................... 5-21 SLSWDS1500 ..................................................................... 5-22 SLSWP2DBB thru SLSWP2DTW ....................................... 5-21 SLSWPS1500 and SLSWUS1500 ...................................... 5-22 SM300A46000 thru SM380A46010 .................................. 20-10 SM600A21600 thru SM656A44806FP .............................. 20-10 SM900A100000 thru SM956A890000 .............................. 20-11 SMD and SMDOEM ............................................................ 4-16 SMSDL thru SMSWXTR ....................................................... 4-4 SN03 and SN03C................................................................ 3-12 SN0310 and SN0310C........................................................ 3-19 SN0610 and SN0610C........................................................ 3-12 SN1000MA .......................................................................... 7-58 SN100FA............................................................................. 7-58 SN1200 ............................................................................... 7-58 SN12125 and SN12200 ...................................................... 7-13 SN20 ................................................................................... 7-13 SN20A ................................................................. 3-2, 3-12, 7-58 SN20C................................................................................. 3-12 SN20NI................................................................ 3-2, 3-12, 7-58 SN225KA ............................................................................ 7-58 SN30 ................................................................................... 7-13 SN400LA ............................................................................. 7-58 SN42 ................................................................................... 7-13 SNC400LX .......................................................................... 7-58 SNC800LX .......................................................................... 7-58 SO1020M100S and SO2040M200S ................................... 1-20 SP1T87A ............................................................................. 4-27 SQ1B21A thru SQ1T87A .................................................... 4-26 SR2A101BD thru SR2B202BD ......................................... 23-39 SR2CBL01 ........................................................................ 23-40 SR2CBL06 ............................................................. 16-95, 23-40 SR2COM01 ....................................................................... 23-40 SR2D101BD thru SR2E201FU ......................................... 23-39 SR2MEM01 thru SR2USB01 ............................................ 23-40 SR3B101B thru SR3XT61JD ............................................ 23-40 SRCTV12 ............................................................................ 7-42 SS03 thru SS20 ......................................................... 3-11, 8-16 SS0306SK.................................................................. 3-11, 8-16 SS10SK...................................................................... 3-11, 8-16 SS212AB thru SS212AC..................................................... 11-5 SS2PL ................................................................................. 11-5 SS312 ................................................................................. 11-5 SS4BLC .............................................................................. 9-40 SSLEN ................................................................................ 15-6 SSPB................................................................................... 15-6 STRM .................................................................................. 4-11 STS3000 ............................................................................. 4-11 SU2040M200C.................................................................... 1-20 SU2X6TRIM ........................................................................ 1-22 SU3040D300CB thru SU3040D400FN ............................... 1-21 SU3040M200R and SU3040M225R ................................... 1-20 SU816D200C ...................................................................... 1-19 T2A thru T9A ....................................................................... 7-46 T327N and T327NR .............................................................. 3-2 TCSAMT31FP thru TCSMCN1FQM2 ............................... 20-12 TIKFD .................................................................................. 9-15 TMSCE................................................................................ 4-13 TR5 ..................................................................................... 15-6 TSXCANCA50 thru TSXCANCA300 ................................. 16-96 TSXCANKCDF180T thru TSXCANKCDF90TP................. 16-96 TSXPBSCA100 and TSXPBSCA400 ................................ 16-96 TUSEAL .............................................................................. 7-53 TVS120LC5 thru TVS120LC20 ............................................. 6-7 TVS120XR40B and TVS120XR40S ..................................... 6-6 TVS120XRB and TVS120XRS ............................................. 6-6 TVS12FMK and TVS12RMU ................................................ 6-2 TVS1EBA12A thru TVS1EBA24SI ........................................ 6-2 TVS1EMA12A thru TVS1EMA48AI....................................... 6-2 TVS1HWA12X thru TVS1HWA80X ...................................... 6-6 TVS1IMA12O thru TVS1IMA24O.......................................... 6-5
i-31
ALPHA-NUMERIC LISTING
TVS1XW100C ....................................................................... 6-6 TVS20FMK ............................................................................ 6-2 TVS230LC5 thru TVS230LC20 ............................................. 6-7 TVS230XR40B and TVS230XR40S...................................... 6-6 TVS2EBA12A thru TVS2EBA24SI ........................................ 6-2 TVS2HWA12X thru TVS2HWA80X....................................... 6-6 TVS2IMA12O thru TVS2IMA24O .......................................... 6-5 TVS2MEMA12A thru TVS2MEMA36SSWT .......................... 6-2 TVS2XW100C ....................................................................... 6-6 TVS3EBA12A thru TVS3EBA24SI ........................................ 6-2 TVS3EMA12A thru TVS3EMA48AI ....................................... 6-2 TVS3HWA12X thru TVS3HWA80X....................................... 6-6 TVS3IMA12O thru TVS3IMA24O .......................................... 6-5 TVS3XW100C ....................................................................... 6-6 TVS4EBA12A thru TVS4EBA24SI ........................................ 6-2 TVS4EMA12A thru TVS4EMA48AI ....................................... 6-2 TVS4HEMA12A thru TVS4HEMA20SI.................................. 6-2 TVS4HWA12X thru TVS4HWA80X....................................... 6-6 TVS4IMA12O thru TVS4IMA24O .......................................... 6-5 TVS4MEMA12A thru TVS4MEMA36SSWT .......................... 6-2 TVS4XW100C thru TVS6XW100C........................................ 6-6 TVS8EBA12A thru TVS8EBA24SI ........................................ 6-2 TVS8EMA12A thru TVS8EMA48AI ....................................... 6-2 TVS8HEMA12A thru TVS8HEMA20SI.................................. 6-2 TVS8IMA12O thru TVS8IMA24O .......................................... 6-5 TVS8MEMA12A thru TVS8MEMA32SI ................................. 6-2 TVS8XW100C and TVS9XW100C........................................ 6-6 TXSCUSB485.................................................................... 16-95 U92197CCCPL...................................................................... 2-2 UAK7T ................................................................................... 2-2 UATRS101B thru UATRS213B ............................................. 2-2 UBHMRS212B....................................................................... 2-2 UFTL...................................................................................... 9-9 UGHTRS101L and UGHTRS111C........................................ 2-2 UHTRS101B thru UHTRS223A............................................. 2-2 UK7T ..................................................................................... 2-2 URS101BCPL thru URS212ADQ .......................................... 2-2 URTRS101B and URTRS213B ............................................. 2-2 US11220018 thru US36020018 .......................................... 7-13 USMBLK and USMBTC....................................................... 7-13 UT2R1121B thru UT6R2392TU ............................................ 2-3 UTH4203T thru UTH7300T ................................................... 2-2 UTRS101B thru UTRS213B .................................................. 2-2 UTS3 ................................................................................... 7-53 UTZRS101A .......................................................................... 2-2 V0 thru V6 ............................................................................. 8-4 VBD0 thru VBD2.................................................................... 8-3 VBDN12 and VBDN20........................................................... 8-2 VBF0 thru VBF6 .................................................................... 8-3 VC1GU thru VC6GU.............................................................. 8-3 VCCD0 thru VCCD2 .............................................................. 8-3 VCCDN12 and VCCDN20 ..................................................... 8-2 VCCF0 thru VCCF6............................................................... 8-3 VCD0 thru VCD2 ................................................................... 8-3 VCDN12 and VCDN20 .......................................................... 8-2 VCEL02114S1 thru VCEL07512H2...........14-11, 16-70, 16-122 VCELSK1 thru VCELSK4 .................................................. 14-11 VCF0 thru VCF6 .................................................................... 8-3 VCFN12GE and VCFN20GE................................................. 8-2 VJDSNDTMSV11M ................................................ 16-9216-94 VM118CD0000 thru VM1VM18PTOQ............................... 20-10 VN12 and VN20..................................................................... 8-2 VVD0 thru VVE4.................................................................... 8-3 VW3A1101 thru VW3A1103 ................................................ 26-9 VW3A1104R10 thru VW3A1104R50........................ 16-96, 26-9 VW3A1104R100.................................................................. 26-9 VW3A1105 .......................................................................... 26-9 VW3A21101 thru VW3A21315 ............................................ 26-5 VW3A3101 thru VW3A3503 ................................................ 26-9 VW3A31101 thru VW3A31817 ............................................ 26-5 VW3A8104 ....................................................18-31, 26-9, 26-17 VW3A8105 ........................................................................ 26-17 VW3A8106 .........................................16-95, 18-31, 26-9, 26-17
i-32
VW3A8111 ............................................................. 18-31, 26-17 VW3A8114 ...........................................................................26-9 VW3A8306R thru VW3A8306TF10....................................16-96 VW3A8306R03 thru VW3A8306TF10................................26-17 VW3A9201 thru VW3A9205PF ..........................................26-11 VW3A9206 thru VW3A9208..................................... 26-5, 26-11 VW3A9209 thru VW3A9217...............................................26-11 VW3A9301 thru VW3A9407...............................................26-10 VW3A9501 thru VW3A9515...............................................26-11 VW3CANA71 .......................................................................26-9 VW3CANKCDF180T............................................................26-9 VW3G4104............................................................. 18-32, 26-15 VW3G48101.......................................................................26-17 VY1H4101..........................................................................26-16 VZ0 thru VZ9..........................................................................8-5 VZ10 thru VZ31......................................................................8-5 VZN05 thru VZN30.................................................................8-2 W808780210111 and W808780220111 ............................26-17 WMB361362 thru WMB363364 ............................. 14-10, 14-11 WS363 thru WS384 ............................................... 14-10, 14-11 XACA009 .........................................................................19-116 XACA02 thru XACA207 ...................................................19-114 XACA9411 thru XACA9419 .............................................19-115 XACA971 thru XACB961 .................................................19-116 XACD21A0101 thru XACD21A1241 ................................19-114 XACS101 thru XACS105 .................................................19-115 XALD01 thru XALD05 ........................................................19-97 XALD101 thru XALD341 ....................................................19-96 XALK01 ..............................................................................19-97 XALK174 thru XALK194.....................................................19-96 XALZ09 ..............................................................................19-97 XAPA1100 thru XAPA4100................................................19-97 XAPE301 thru XAPE905....................................................19-98 XAPG19100 thru XAPG59505 ...........................................19-98 XAPZ100 thru XAPZ316 ....................................................19-97 XB4BA21 thru XB4BA65....................................................19-23 XB4BA821 thru XB4BA962................................................19-30 XB4BD21 thru XB4BVG6....................................... 19-2319-25 XB4BW11B5 thru XB4BW36G5.........................................19-25 XB5AA21 thru XB5AA65....................................................19-42 XB5AA831 thru XB5AA86202............................................19-50 XB5AC21 thru XB5AL45 ........................................ 19-42, 19-43 XB5AL84101 and XB5AL84201.........................................19-50 XB5AL845 ..........................................................................19-42 XB5AP21 thru XB5AVG6 ....................................... 19-4219-44 XB5AW11B5 thru XB5AW36G5.........................................19-44 XB5DSB thru XB5KSM ......................................................19-50 XB6AA11B thru XB6DW6B5B ............................... 19-1219-14 XBFX13.................................................................. 19-40, 19-61 XBTN410................................................................ 16-9216-94 XBTZ938 ............................................................................16-96 XBY2U ................................................................... 19-39, 19-60 XCDR2110N12 thru XCDR2527N12 ...................................21-5 XCKD2106N12 thru XCKD25H0N12 .................................21-14 XCKJ10511 thru XCKJ20541.............................................21-27 XCKL10011 thru XCKL50041 ............................................21-20 XCKL102 thru XCKL521 ....................................................21-20 XCKN2102P20 thru XCKN2949P20 ..................................21-18 XCKP2106N12 thru XCKP25H0N12..................................21-14 XCKS101 thru XCKS559 ...................................................21-19 XCKT2102N12 thru XCKT2118N12...................................21-15 XCMD2102L1 thru XCMN2110L1......................................21-14 XCNR2102P20 thru XCNR2927P20..................................21-18 XCPR2110N12 thru XCPR2527N12..................................21-15 XD4PA12 thru XD5PA24 ...................................................19-30 XE2NP2151 thru XE2SP2158............................................21-30 XENG1191 thru XENG3791.............................................19-115 XENP2151 .........................................................................21-21 XENT1192........................................................................19-115 XESP2021 thru XESP2031................................................21-30 XESP2151 and XESP2158 ................................................21-21 XGCS4901201 thru XGSZX08L5.......................................20-12 XMLA001S2S13 thru XMLDM02V1S13...............................22-9
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
XMLF010D2026 thru XMLFM01D2026 ............................... 22-6 XMLG001D23 thru XMLGM01D73...................................... 22-4 XMLGZ001 .......................................................................... 22-5 XMLZL001 thru XMLZL006 ................................................. 22-9 XMLZL008 thru XMLZL010 ................................................. 22-7 XMLZL011 ........................................................................... 22-9 XRIADI................................................................................. 15-6 XRIAI ................................................................................... 15-6 XS106BLNAL2 thru XS230SAPAM12........................ 20-7, 20-8 XS2L2SANAL2 thru XS2L2SAPAM12 ................................ 20-8 XS612B2NAL01M12 thru XS630B2PBL01M12 .................. 20-6 XS8C1A1MAL01U20 thru XS8E1A1PBM8 ......................... 20-5 XSZB108 thru XSZB130............................................. 20-6, 20-7 XSZBC00 thru XSZBE90..................................................... 20-5 XSZBPM12.......................................................................... 20-6 XSZCA101Y thru XSZCA911Y............................................ 20-9 XSZCD101Y and XSZCD111Y ................20-2, 20-7, 20-9, 22-5 XSZCD102Y and XSZCD103Y .................................. 22-5, 22-7 XSZCD1501Y and XSZCD1511Y ....................................... 20-9 XSZCK101Y and XSZCK111Y................................... 20-6, 20-9 XSZCS101 thru XSZCS151 ..............................20-2, 20-6, 20-9 XSZCS901 and XSZCS911................................................. 20-9 XT112S1NAL2 thru XT130B1PCM12 ................................. 20-8 XUB1APANL2 thru XUB9BPANM12 ................................... 20-2 XUBLAKCNL2T thru XUBTSPSWM12................................ 20-3 XUK1APANL2 thru XUK9ARCNL2...................................... 20-4 XUM1APANL2 thru XUM9APBNM8.................................... 20-4 XUN0AKSNM12T thru XUN9APANM12 ............................. 20-4 XUX0AKSAM12T thru XUX9ARCNT16 .............................. 20-4 XUZA118 thru XUZC80 ....................................................... 20-2 XVBC00 thru XVBZ04A...................................... 19-10619-109 XVC1B1K thru XVCZ23...................................... 19-104, 19-105 XVDC02........................................................................... 19-109 XVEC21 thru XVEZ13 ..................................................... 19-109 XVLA123 thru XVLZ912 .................................................... 19-11 XVPC02 thru XVPCX13 ..................................... 19-110, 19-111 XVR08B03 thru XVRZR3 ................................................ 19-103 XVS14BMW..................................................................... 19-112 XVS72BMBN thru XVS72BMWP .................................... 19-112 XX6V3A1NAM12 thru XX9V3A1H3M12............................ 20-11 XXZPB100........................................................................... 20-9 XXZPM100M12 ................................................................... 20-9 XZCC12FCM40B and XZCC12FDM40B............................. 22-5 XZCC12FDM40V...............................................20-9, 22-5, 22-7 XZCP1141L10 thru XZCP1241L5 .............................. 22-5, 22-7 XZCP1764L2 thru XZCP1764L10 ....................................... 22-7 XZCR1511041C1 thru XZCR1512041C2............................ 22-7 YA060HD............................................................................. 7-40 YA1200R3 thru YA1200R7.................................................. 7-40 YA150HD and YA150JD ..................................................... 7-40 YA2000R3 thru YA2500R7.................................................. 7-40 YA250J35 ............................................................................ 7-40 YA250P3 thru YA800P7 ...................................................... 7-40 YLED ................................................................................... 15-6 ZA2BB2 thru ZA2BV07.................................................... 19-115 ZALVB1 thru ZALVM6 ....................................................... 19-97 ZB2BE101 and ZB2BE102.............................................. 19-115 ZB2BP012 thru ZB2BP016..................................... 19-41, 19-62 ZB2BV006 and ZB2BV007.............................................. 19-115 ZB2BY2002 thru ZB2BY4101.......................................... 19-116 ZB2BY23 ......................................................................... 19-116 ZB2SZ3 ........................................................................... 19-116 ZB4B564............................................................................ 19-28 ZB4BA0 thru ZB4BC64 .......................................... 19-26, 19-27 ZB4BD2 thru ZB4BG9 ............................................ 19-29, 19-30 ZB4BH01 thru ZB4BH06 ................................................... 19-27 ZB4BH013 thru ZB4BH063 ............................................... 19-32 ZB4BH1 thru ZB4BH6 ....................................................... 19-27 ZB4BH13 thru ZB4BH63 ................................................... 19-32 ZB4BJ2 thru ZB4BJ8......................................................... 19-29 ZB4BK12 thru ZB4BK18.................................................... 19-33 ZB4BL1 thru ZB4BL6 ........................................................ 19-26 ZB4BL232 thru ZB4BL435 ................................................ 19-26
2009 Schneider Electric All Rights Reserved
ZB4BL8312 thru ZB4BL9434 ............................................ 19-27 ZB4BP1 thru ZB4BP68 ..................................................... 19-26 ZB4BR2 thru ZB4BR6 ....................................................... 19-27 ZB4BS12 thru ZB4BT84 ................................................... 19-28 ZB4BV01 thru ZB4BVJ6 ................................................... 19-31 ZB4BW031 thru ZB4BW0G65 .......................................... 19-34 ZB4BW11 thru ZB4BW663 ............................................... 19-32 ZB4BW811723 thru ZB4BW843743 ................................. 19-33 ZB4BX2 and ZB4BX4 ....................................................... 19-28 ZB4BZ009 thru ZB4BZ1055................................... 19-35, 19-40 ZB4BZ106 and ZB4BZ107 ..................................... 19-35, 19-56 ZB4BZ141 ......................................................................... 19-34 ZB4BZ1905 thru ZB4BZ905................................... 19-40, 19-61 ZB4SZ3 ............................................................................. 19-40 ZB5AA0 thru ZB5AA9234 ...................................... 19-4519-47 ZB5AC2 thru ZB5AC64 ..................................................... 19-46 ZB5AD2 thru ZB5AG9............................................ 19-49, 19-50 ZB5AH01 thru ZB5AH06 ................................................... 19-47 ZB5AH013 thru ZB5AH063 ............................................... 19-53 ZB5AH1 thru ZB5AH6 ....................................................... 19-47 ZB5AH13 thru ZB5AH63 ................................................... 19-53 ZB5AJ2 thru ZB5AJ8 ........................................................ 19-49 ZB5AK123 thru ZB5AK183 ............................................... 19-54 ZB5AL1 thru ZB5AL6 ........................................................ 19-45 ZB5AL232 thru ZB5AL435 ................................................ 19-46 ZB5AL8312 thru ZB5AL9434 ............................................ 19-47 ZB5AP1 thru ZB5AP68 ..................................................... 19-45 ZB5AR2 thru ZB5AR6 ....................................................... 19-46 ZB5AS12 thru ZB5AS964 ................................................. 19-48 ZB5AT2 thru ZB5AT84...................................................... 19-48 ZB5AT8643M .................................................................... 19-54 ZB5AV01 thru ZB5AV07S ................................................. 19-51 ZB5AV18B1 thru ZB5AV18G6 .......................................... 19-52 ZB5AV3 thru ZB5AVJ6 ..................................................... 19-52 ZB5AW031 thru ZB5AW0G65 .......................................... 19-55 ZB5AW11 thru ZB5AW563 ............................................... 19-53 ZB5AW713 thru ZB5AW843743 ....................................... 19-54 ZB5AX2 and ZB5AX4 ....................................................... 19-48 ZB5AZ009 .............................................................. 19-56, 19-57 ZB5AZ101 thru ZB5AZ105................................................ 19-55 ZB5AZ1015 thru ZB5AZ1055............................................ 19-57 ZB5AZ141 ......................................................................... 19-55 ZB5AZ31 ........................................................................... 19-61 ZB5AZ901 .............................................................. 19-61, 19-97 ZB5AZ902 ......................................................................... 19-61 ZB5AZ905 .............................................................. 19-61, 19-97 ZB5CA1 thru ZB5CA66 ..................................................... 19-45 ZB5CH01 thru ZB5CH06 .................................................. 19-47 ZB5CL1 thru ZB5CL6........................................................ 19-45 ZB5CV013 thru ZB5CV063 ............................................... 19-51 ZB5CW113 thru ZB5CW363 ............................................. 19-53 ZB5SZ3 ....................................................... 19-40, 19-61, 19-97 ZB5SZ5 ............................................................................. 19-61 ZB6AA1 thru ZB6AA9 ....................................................... 19-17 ZB6AD22 thru ZB6AD28 ........................................ 19-17, 19-18 ZB6AE1 thru ZB6AF9 ....................................................... 19-16 ZB6AGA thru ZB6AGT ...................................................... 19-19 ZB6AS834 ......................................................................... 19-17 ZB6AV1 thru ZB6AW9 ...................................................... 19-16 ZB6CA1 thru ZB6CA9 ....................................................... 19-17 ZB6CD22 thru ZB6CD28 ....................................... 19-17, 19-18 ZB6CE1 thru ZB6CF9 ....................................................... 19-16 ZB6CGA thru ZB6CGT ..................................................... 19-19 ZB6CV1 thru ZB6CW9 ...................................................... 19-16 ZB6DA1 thru ZB6DA9 ....................................................... 19-17 ZB6DD22 thru ZB6DD28 ....................................... 19-17, 19-18 ZB6DE1 thru ZB6DF9 ....................................................... 19-16 ZB6DGA thru ZB6DGT ..................................................... 19-19 ZB6DV1 thru ZB6DW9 ...................................................... 19-16 ZB6E1B thru ZB6EM0B .................................................... 19-15 ZB6Y001 thru ZB6Y019 .................................................... 19-22 ZB6Y2178 thru ZB6Y2387 ..................................... 19-20, 19-22 ZB6Y7001 ................................................... 19-13, 19-17, 19-22
i-33
ALPHA-NUMERIC LISTING
ZB6Y7330 ...................................................19-13, 19-17, 19-22 ZB6Y905 ........................................................................... 19-22 ZB6YA001 thru ZB6YA006................................................ 19-22 ZB6YA100 thru ZB6YA626................................................ 19-21 ZB6YB028 ......................................................................... 19-22 ZB6YC100 thru ZB6YC626 ............................................... 19-21 ZB6YD001 ......................................................................... 19-22 ZB6YD100 thru ZB6YD626 ............................................... 19-21 ZB6YD20 thru ZB6YD22 ........................................ 19-20, 19-22 ZB6YG095......................................................................... 19-22 ZB6YJ012.......................................................................... 19-22 ZB6Z1B thru ZB6ZH05B ................................................... 19-15 ZBA1 thru ZBA9 ..................................................... 19-39, 19-60 ZBA131 thru ZBA639 ............................................. 19-39, 19-60 ZBCV0113 thru ZBCW9363 .............................................. 19-62 ZBCY1101 ......................................................................... 19-60 ZBDD2.................................................................... 19-40, 19-61 ZBE101 thru ZBE1026P ..............................19-36, 19-36, 19-56 ZBE201 thru ZBE205 ............................................. 19-35, 19-56 ZBG2201 and ZBG2401......................................... 19-30, 19-50 ZBG3131A thru ZBG3131AP ................................. 19-40, 19-61 ZBG4201 and ZBG4401......................................... 19-30, 19-50 ZBG421E thru ZBG520EP ..................................... 19-40, 19-61 ZBL1 thru ZBL9 ...................................................... 19-39, 19-60 ZBP0 thru ZBV017 ................................................. 19-41, 19-62 ZBV6 ...................................................................... 19-35, 19-56 ZBVB1 thru ZBVB6................................................. 19-35, 19-56 ZBVB15 thru ZBVB65............................................. 19-36, 19-57 ZBVBG1 thru ZBVBG6 ........................................... 19-35, 19-56 ZBVG1 thru ZBVG6................................................ 19-35, 19-56 ZBVG15 thru ZBVG65............................................ 19-36, 19-57 ZBVJ1 thru ZBVJ6.................................................. 19-35, 19-56 ZBVJ15 thru ZBVJ65.............................................. 19-36, 19-57 ZBVM1 thru ZBVM6 ............................................... 19-35, 19-56 ZBVM15 thru ZBVM65 ........................................... 19-36, 19-57 ZBW008 thru ZBW937 ........................................... 19-41, 19-62 ZBY01001 thru ZBY05005 ..................................... 19-38, 19-59 ZBY1101 thru ZBY1912 ......................................... 19-39, 19-60 ZBY2002 thru ZBY2186 ......................................... 19-37, 19-58 ZBY2303 thru ZBY4H101....................................... 19-37, 19-58 ZBY5101 and ZBY5102.......................................... 19-38, 19-59 ZBY6101 thru ZBY6H102....................................... 19-37, 19-58 ZBY8101 thru ZBY9330 ............................................. 9-28, 9-48 ZBY9101T .............................................................. 19-40, 19-61 ZBY9330T thru ZBZ1606 ....................................... 19-40, 19-61 ZBZ28..................................................................... 19-40, 19-61 ZBZ32 thru ZBZ35.................................................. 19-37, 19-58 ZBZ3605 thru ZBZ8................................................ 19-40, 19-61 ZCD21 thru ZCDEP20....................................................... 21-17 ZCE01 thru ZCEH2 ........................................................... 21-16 ZCKD01 thru ZCKD59............................................ 21-1921-21 ZCKE05 thru ZCKE676 .......................................... 21-29, 21-30 ZCKG00............................................................................. 21-21 ZCKJ01 thru ZCKJ04 ........................................................ 21-30 ZCKJ1 thru ZCKJ5 ................................................. 21-27, 21-28 ZCKL1 thru ZCKL18 .......................................................... 21-21 ZCKS7 and ZCKS9 ........................................................... 21-19 ZCKY11 thru ZCKY91 ............................................ 21-21, 21-30 ZCMC21L1 thru ZCMC39L5.............................................. 21-17 ZCMD21 thru ZCMD41...................................................... 21-17 ZCP21 thru ZCP39 ............................................................ 21-17 ZCPEF12 thru ZCPEP20................................................... 21-17 ZCT21P16 and ZCT25P16................................................ 21-17 ZCY15 thru ZCY91 ............................................................ 21-16 ZENL1111 ......................................................................... 19-97 1.5S1F thru 1.5S8F ............................................................. 14-4 1000T13H thru 1000T62H................................................... 14-8 1003880A .............................................................................. 2-2 100S3HNV........................................................................... 14-5 100SNA and 225SNA................................................... 3-7, 7-58 100SV1A thru 100SV82A .................................................... 14-4 1010004 thru 10100010 .................................................... 21-34 10S1F thru 10S8F ...................................................... 14-4, 14-5
i-34
112T13H thru 112T62H .......................................................14-8 112T3HNV ...........................................................................14-5 118T144HDIT and 118T145HDIT ........................................14-7 11T144HDIT and 11T145HDIT ............................................14-7 12710 thru 12738 ...................................................................6-5 14210 and 14211 .................................................................7-20 145T144HDIT and 145T145HDIT ........................................14-7 1500T13H thru 1500T62H ...................................................14-8 150SV1A thru 150SV82A.....................................................14-4 150T13H thru 150T62H .......................................................14-8 150T3HNV ...........................................................................14-5 155DE175 thru 155DE360 .................................................11-10 15S1FSS thru 15S40FSS ....................................................14-5 15SM5010 thru 15SM5400 ................................................11-14 15T144HDIT and 15T145HDIT ............................................14-7 15T2F thru 15T75F .................................................... 14-4, 14-5 167S13H thru 167S62H .......................................................14-8 17400 ...................................................................................7-20 174CEV30020....................................................................26-17 175DE010 thru 175DE200 ..................................... 11-10, 11-14 175T144HDIT and 175T145HDIT ........................................14-7 1S1F thru 1S8F.......................................................... 14-4, 14-5 2000T13H thru 2000T62H ...................................................14-8 20T144HDIT and 20T145HDIT ............................................14-7 220T144HDIT and 220T145HDIT ........................................14-7 225T13H thru 225T62H .......................................................14-8 225T3HNV ...........................................................................14-5 2500T13H thru 2500T62H ...................................................14-8 250S13H thru 250S62H .......................................................14-8 250SV1B thru 250SV82B.....................................................14-4 2510FF1 thru 2510FF74P....................................................16-2 2510FG02 thru 2510FGJ6P.................................................16-2 2510FK1 thru 2510FL1 ........................................................16-9 2510FN1 thru 2510FN6 .......................................................16-9 2510FN10 thru 2510FN45 ...................................................16-9 2510FO1 thru 2510FO4P.....................................................16-2 2510FR1 thru 2510FR2 .......................................................16-2 2510FS1 thru 2510FSJ4P....................................................16-2 2510FW1 thru 2510FW2P ...................................................16-2 2510KF1 thru 2510KW6C ....................................................16-3 2510MBA1 thru 2510MCW5 ................................................16-6 2510PB1 ..............................................................................16-9 2510TBG1 thru 2510TCO5 ..................................................16-6 2511KF11 thru 2511KO2T ...................................................16-3 2511MBG1 thru 2511MCO1 ................................................16-7 2511TBG1 thru 2511TCO1 ..................................................16-7 2512FF11 thru 2512FS202P................................................16-2 2512KF11 thru 2512KO2T ...................................................16-3 2512MBG1 thru 2512MCO1 ................................................16-7 2512TBG1 thru 2512TCO1 ..................................................16-7 2540902240 .......................................................................19-72 2549909510 .........................................................................15-6 2550101002 .......................................................................19-82 2550101003 .......................................................................19-89 2550101013 .......................................................................19-82 2550101020 ................................................ 19-10, 19-82, 19-89 2550101024 .......................................................................19-10 2550101025 thru 2550101037 ...........................................19-82 2550101040 .......................................................................19-10 2550105003 thru 2550105005 ............................... 19-11, 19-89 2550105007 thru 2550105014 ...........................................19-89 25S1FSS thru 25S40FSS ....................................................14-5 2601AF2 thru 2601BW1.....................................................16-10 2640KIT................................................................................4-26 27105 thru 27118 .................................................................7-20 275T144HDIT and 275T145HDIT ........................................14-7 27T144HDIT and 27T145HDIT ............................................14-7 29007 .................................................................. 1-22, 2-6, 2-15 29008W........................................................ 1-22, 2-3, 2-6, 2-15 2920910001 ................................................. 1-22, 2-3, 2-6, 2-15 29273 ...................................................................................7-42 29286 and 29287 .................................................................7-42 29314 ...................................................................................7-41
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
29346................................................................................... 7-37 29348................................................................................... 7-39 2934D14G1 thru 2934D34G1............................................ 21-32 29375................................................................................... 2-15 29375 thru 32478 ................................................................ 7-38 2941101100....................................................................... 19-89 2959S49W25A thru 2959S49W39A .................................. 23-29 2S1F thru 2S8F .......................................................... 14-4, 14-5 2W485C............................................................................... 4-15 3000PLU1SEP thru 3000PMUSITE .................................... 4-23 3000T32H thru 3000T62H................................................... 14-8 3003302753 and 3003302754........................................... 14-17 300T13H thru 300T62H....................................................... 14-8 300T3HNV........................................................................... 14-5 3010215901....................................................................... 16-70 3020B012 thru 3020B244.................................................... 4-15 3020E012 thru 3020E244.................................................... 4-15 3052835850S and 3052836950S........................................ 8-16 3090SCCT022 thru 3090SCCT164..................................... 4-15 30T2F thru 30T75F..................................................... 14-4, 14-5 3100206050 thru 3100240340 .......................................... 16-88 3103248801....................................................................... 21-25 3103281501....................................................................... 21-25 3105204101....................................................................... 19-89 3105205901....................................................................... 19-89 3105206750....................................................................... 19-72 3105211101....................................................................... 19-72 3105217001....................................................................... 19-89 3105404408....................................................................... 19-89 3105406401....................................................................... 19-89 3110112001..................................................................... 19-100 3110251450 and 3110251451......................................... 16-117 3110440050..................................................................... 16-114 3110451250 thru 3110451256 ........................................ 16-116 3112350150 thru 3112350156 ........................................ 16-116 3116118474 thru 3116118477 .......................................... 16-82 3116154764 thru 3116155368 .......................................... 16-82 32508 and 32510................................................................. 7-39 32510................................................................................... 2-15 32514 and 32518................................................................. 7-42 32521 thru 32525 ................................................................ 7-42 32532 thru 32534 ................................................................ 7-42 32548................................................................................... 7-42 32553 thru 32562 ................................................................ 7-38 32562 and 32563................................................................. 7-42 32570................................................................................... 7-38 32597 thru 32606 ................................................................ 7-37 32614................................................................................... 7-38 32621................................................................................... 7-38 32642 thru 32649 ................................................................ 7-37 32839 thru 32847 ................................................................ 7-37 330T144HDIT and 330T145HDIT ....................................... 14-7 333S13H thru 333S62H ...................................................... 14-8 34T144HDIT and 34T144HDIT ........................................... 14-7 36940 thru 36945 ................................................................ 7-25 36950 thru 36967 ................................................................ 7-41 37S3HNV............................................................................. 14-5 3S1F thru 3S8F .......................................................... 14-4, 14-5 3T2F thru 3T5F........................................................... 14-4, 14-5 400SN.................................................................................. 7-58 405WBAF010 thru 415WBAF400...................................... 11-14 40T144HDIT thru 40T145HDIT ........................................... 14-7 41940................................................................................... 7-37 41950................................................................................... 7-38 42878................................................................................... 7-38 42888................................................................................... 7-37 4319900406......................................................................... 15-6 4319950001......................................................................... 15-6 43362................................................................................... 7-41 440T144HDIT thru 440T145HDIT ....................................... 14-7 4458D20X3........................................................................ 19-89 4487D63XI......................................................................... 19-89 4491S1W21 thru 4491S1W37........................................... 23-29
2009 Schneider Electric All Rights Reserved
45T3HNV ............................................................................ 14-5 490NAD01103 thru 490NAD01105 ................................... 16-96 490NTW00002 thru 490NTW00080U ............................... 16-96 500SV1B thru 500SV82B.................................................... 14-4 500T13H thru 500T62H ...................................................... 14-8 50437 thru 50442 ..................................................... 7-47, 16-95 50485 thru 50486 ..................................................... 7-47, 16-85 50S3HNV ............................................................................ 14-5 50SV1A thru 50SV82A........................................................ 14-4 515608 .............................................................................. 12-13 515614 .............................................................................. 12-13 51T144HDIT and 51T145HDIT ........................................... 14-7 53004BB thru 53021BB ...................................................... 15-6 550T144HDIT and 550T145HDIT ....................................... 14-7 55391 .................................................................................. 7-41 55DE010 thru 55DE600 ......................................... 11-10, 11-14 56053 thru 56058 ................................................................ 7-47 56300 thru 56363 ................................................................ 7-47 56370TD thru 56493TD ...................................................... 7-47 56400 thru 56463 ................................................................ 7-47 5GS010 thru 5GS200.......................................................... 11-7 5J ........................................................................ 1-22, 2-6, 2-15 5S1F thru 5S8F .......................................................... 14-4, 14-5 5SM5010 thru 5SM5400 ................................................... 11-14 60100 thru 60399 ................................................................ 7-16 60406 thru 60421 ................................................................ 7-17 60488 .................................................................................. 7-20 60949 thru 60999 ................................................................ 7-18 6301002350 ........................................................................ 15-6 6301060250 ........................................................................ 15-6 6382G3MODEM.................................................................. 5-26 6382RS485G3KIT ............................................................... 5-26 63T144HDIT and 63T145HDIT ........................................... 14-7 6508804101 ...................................................................... 19-89 6508805201 thru 6508805206 .......................................... 19-82 6508805207 thru 6508805209 .......................................... 19-10 6508805210 thru 6508805214 .......................................... 19-82 6509701801 thru 6509705001 .......................................... 19-89 6512231201 ...................................................................... 19-89 6512232801 ...................................................................... 19-72 6512240601 ...................................................................... 19-89 6512243201 ...................................................................... 19-89 6515802701 ...................................................................... 19-89 6516002379 thru 6516002390 ........................................ 19-116 685823 thru 685831 ............................................................ 7-44 6T2F thru 6T5F .......................................................... 14-4, 14-5 7400ENT9 thru 7400ENT13.............................................. 14-11 750SV1F thru 750SV82F .................................................... 14-4 750T13H thru 750T62H ...................................................... 14-8 75S3HNV ............................................................................ 14-5 75T144HDIT and 75T145HDIT ........................................... 14-7 7A1 thru 7S ......................................................................... 21-9 7S1F thru 7S8F .......................................................... 14-4, 14-5 7T144HDIT and 7T145HDIT ............................................... 14-7 7XA1 thru 7XJ7N ................................................................ 21-9 8011010401 and 8011010501 .............................................. 9-9 82254 thru 82455 ....................................................... 3-17, 3-18 82255R thru 82455R .................................................. 3-17, 3-18 8430MPDV20 thru 8430MPSV29 ..................................... 23-35 8501CDO15 thru 8501CO8............................................... 23-14 8501KF12 thru 8501KPD13P14.......................................... 23-9 8501KU12 thru 8501KUD13P14 ......................................... 23-9 8501NH7 thru 8501NH82.................................................. 23-13 8501NR34 thru 8501NR82B ............................................. 23-13 8501RS4 thru 8501RS44P14................................. 23-1123-13 8501RSD4 thru 8501RSD44P14 ........................... 23-1123-13 8501X011 .......................................................................... 16-71 8501XA1 ........................................................................... 23-23 8501XB20 thru 8501XBR20 .............................................. 23-23 8501XC1 thru 8501XC4 .................................................... 23-23 8501XDL ........................................................................... 23-23 8501XDO00 thru 8501XDO80XDL ................................... 23-22 8501XJ1 thru 8501XM8 .................................................... 23-23
i-35
ALPHA-NUMERIC LISTING
8501XMO20 thru 8501XMO60 .......................................... 23-21 8501XO00 thru 8501XO80XL............................................ 23-21 8501XS1............................................................................ 23-23 8501XTD1 and 8501XTD2 ................................................ 23-23 8501XTE1 and 8501XTE2................................................. 23-23 8501XUDO0012 thru 8501XUDO80.................................. 23-22 8502SAG11 thru 8502SJW2 .................................. 16-1316-16 8502VFO3 thru 8502WHO3 ................................... 16-27, 16-28 8536SAG11 thru 8536SJW2 .................................. 16-1716-21 8536WFO3 thru 8536WHO3 ............................................. 16-29 8538SBA11 thru 8538SHW33................................ 16-3016-33 8539SBA1 thru 8539SJW43................................... 16-3416-38 8702SAG1 thru 8702SJW1 .................................... 16-43, 16-44 8702WFO3 thru 8702WHO3 ............................................. 16-49 8736SAG13 thru 8736SJW1 .................................. 16-45, 16-46 8738SBA11 thru 8738SGW35................................ 16-50, 16-51 8739SBA1 thru 8739SHW7.................................... 16-5216-55 8810CBA1 thru 8810UHW4 ................................... 16-5916-61 8903L1L and 8903L3R ...................................................... 16-64 8903LA1000 thru 8903LXWW80....................................... 16-64 8903PBM10 thru 8903PBW11B ........................................ 16-68 8903PBX1 and 8903PBX2 ................................................ 16-68 8903SJA1 thru 8903SZW91................................... 16-6516-67 8910DP11 thru 8910DPA93 ................................... 16-76, 16-77 8910SYD138 thru 8910SYD368........................................ 16-76 8911DPB1 ......................................................................... 16-80 8911DPSG12 thru 8911DSO32 ........................................ 16-80 8911DSS1 ......................................................................... 16-80 8940SSC2007 thru 8940SSG4200 ................................... 16-82 8940WC1S2V03 thru 8940XF4S2V06 .............................. 16-83 8940XSE2025V03 thru 8940XSF4100V06 ....................... 16-82 8940XSG2075 thru 8940XSJ4600 .................................... 16-82 8941CBA06 thru 8941UEW40................................ 16-85, 16-86 8965DA1 and 8965DA2..................................................... 16-89 8965DPR13 thru 8965DPR63 ........................................... 16-89 8965RO10 thru 8965RO13................................................ 16-88 8998BA003AFSMA ............................................................. 17-3 8998CP03 thru 8998CP24 .................................................. 17-6 8998HBA001AFSMA thru 8998HBA010XFTSS.................. 17-5 8998HBF015 thru 8998HBF250 .......................................... 17-6 8998HFA001AFSMA thru 8998HFA010XFTSS .................. 17-5 8998HFF030 thru 8998HFF100 .......................................... 17-7 8998SBA001AFSMA thru 8998SBC100XFTSS.................. 17-3 8998SBF015 thru 8998SBF250 .......................................... 17-6 8998SFA001AFSMA thru 8998SFC100XFTSS .................. 17-4 8998SFF030 thru 8998SFF200........................................... 17-6 8CIIAI .................................................................................. 15-6 9001A20 thru 9001A24 ..................................................... 19-88 9001A29 ............................................................................ 19-10 9001A31 ............................................................................ 19-88 9001A6 thru 9001A9 ......................................................... 19-88 9001B11 thru 9001B25 ..................................................... 19-88 9001B301 thru 9001B342 ................................................. 19-99 9001BFB107 thru 9001BFB226 ...................................... 19-100 9001BGB107 thru 9001BGC315 ..................................... 19-100 9001BOC107 thru 9001BOC362..................................... 19-100 9001BWD219 and 9001BWD220...................................... 19-99 9001C20 thru 9001C31 ..................................................... 19-88 9001C6 thru 9001C9 ......................................................... 19-88 9001FB24 and 9001FB120 ............................................... 19-11 9001G19 thru 9001G31..................................................... 19-88 9001G6 thru 9001G9......................................................... 19-88 9001JN100 thru 9001JN799.............................................. 19-10 9001JP .............................................................................. 19-10 9001JT .............................................................................. 19-10 9001K1 .............................................................................. 19-89 9001K107 thru 9001K111 ................................................. 19-87 9001K13B thru 9001K13M ................................................ 19-88 9001K15 ............................................................................ 19-72 9001K162 .......................................................................... 19-87 9001K16B thru 9001K17Y................................................. 19-88 9001K1L thru 9001K2L ..................................................... 19-65 9001K20 thru 9001K23 .......................................... 19-68, 19-78
i-36
9001K3...............................................................................19-89 9001K30 thru 9001K37 ......................................................19-71 9001K3L thru 9001K3 ........................................................19-65 9001K4...............................................................................19-87 9001K40................................................................. 19-72, 19-89 9001K401J thru 9001K702J...............................................19-67 9001K41 thru 9001K49 ......................................................19-89 9001K42J thru 9001K79J...................................................19-67 9001K5...............................................................................19-87 9001K51 and 9001K52 ......................................................19-87 9001K54 and 9001K55 ......................................................19-89 9001K57.............................................................................19-72 9001K58.............................................................................19-89 9001K6...............................................................................19-87 9001K60 thru 9001K68 ......................................................19-87 9001K685...........................................................................19-87 9001K69.............................................................................19-89 9001K7...............................................................................19-87 9001K70 thru 9001K73 ......................................................19-71 9001K8...............................................................................19-72 9001K85.............................................................................19-72 9001K92B thru 9001K95RM ..............................................19-88 9001K96 and 9001K97 ......................................................19-87 9001KA1 thru 9001KA6 ......................................... 19-81, 19-93 9001KA12 thru 9001KA35 .................................................19-81 9001KA1G thru 9001KA6G................................................19-81 9001KA41 thru 9001KA55 .................................................19-83 9001KM1 thru 9001KMF1 ..................................................19-82 9001KN100AP thru 9001KN999 ............................ 19-85, 19-86 9001KP .................................................................. 19-70, 19-84 9001KQ11 thru 9001KQ15B ..............................................19-71 9001KR1 ............................................................................19-63 9001KR11 thru 9001KR12 .................................................19-72 9001KR131 thru 9001KR153 .............................................19-71 9001KR16 ..........................................................................19-64 9001KR2 ............................................................................19-84 9001KR2 thru 9001KR5 .....................................................19-63 9001KR20 ..........................................................................19-84 9001KR24 and 9001KR25 .................................................19-63 9001KR6 thru 9001KR7 .....................................................19-72 9001KR67 ..........................................................................19-72 9001KR8 thru 9001KR9 .....................................................19-64 9001KRD1 thru 9001KRD3................................................19-72 9001KS11BH13 ...................................................................19-9 9001KS11BM1 ...................................................................16-71 9001KS4 thru 9001KS7 .....................................................19-84 9001KS401 and 9001KS702..............................................19-67 9001KS42 thru 9001KS79 .................................................19-67 9001KS43BH13 ...................................................................19-9 9001KS46BH2 ...................................................................16-71 9001KT...............................................................................19-70 9001KTR ............................................................................19-70 9001KU1 thru 9001KU47 ...................................................19-87 9001KXA ............................................................................19-95 9001KXB ............................................................................19-91 9001KXN100 thru 9001KXN799 ........................................19-94 9001KXPA1A thru 9001KXPC34WAGR ............................19-91 9001KXRA133 thru 9001KXRL34GRGRH37 ....................19-90 9001KXSA125 thru 9001KXSVC5 .......................................9-91 9001L20 thru 9001L24 .......................................................19-88 9001L29 .............................................................................19-10 9001L31 .............................................................................19-88 9001L6 thru 9001L9 ...........................................................19-88 9001OA12 thru 9001OY24.................................................19-11 9001R19 thru 9001R24......................................................19-88 9001R29.............................................................................19-10 9001R31.............................................................................19-88 9001R6 thru 9001R9..........................................................19-88 9001R94.............................................................................19-88 9001S11 thru 9001S25 ......................................................19-88 9001SK1L thru 9001SK2L .................................................19-75 9001SK40 thru 9001SK49 .................................................19-89 9001SK401J thru 9001SK702J..........................................19-77
2009 Schneider Electric All Rights Reserved
ALPHA-NUMERIC LISTING
9001SK42J thru 9001SK79J ............................................. 19-77 9001SK52........................................................................ 19-117 9001SK88J ........................................................................ 19-78 9001SKN100 thru 9001SKN599...................................... 19-117 9001SKP ........................................................................... 19-79 9001SKR1 thru 9001SKR5................................................ 19-73 9001SKR11 thru 9001SKR12............................................ 19-80 9001SKR16 ....................................................................... 19-74 9001SKR20 ....................................................................... 19-84 9001SKR24 thru 9001SKR25............................................ 19-73 9001SKR8 thru 9001SKR9................................................ 19-74 9001SKRU1 thru 9001SKRU11 ...................................... 19-117 9001SKS11BH13 ................................................................ 19-9 9001SKS4 thru 9001SKS7 ................................................ 19-84 9001SKS401 thru 9001SKS702 ........................................ 19-77 9001SKS42 thru 9001SKS79 ............................................ 19-77 9001SKS88 ....................................................................... 19-78 9001SKT1A thru 9001SKT38Y.......................................... 19-79 9001SKTR25A thru 9001SKTR38Y .................................. 19-79 9001SKYP ....................................................................... 19-117 9001T5BE thru 9001Y9 ..................................................... 19-88 9001W29 ........................................................................... 19-10 9001Y29 ............................................................................ 19-10 9002AC1 thru 9002AW9.................................................. 19-119 9006PA12 thru 9006PA30................................................... 20-9 9007A ..................................................................... 21-2221-25 9007AA0 thru 9007AA9M....................................... 21-24, 21-25 9007AB21 thru 9007AP325................................................. 21-6 9007B ................................................................................ 21-22 9007B1 thru 9007B9.......................................................... 21-32 9007B12 thru 9007B27...................................................... 21-32 9007BA0 thru 9007BA9M....................................... 21-24, 21-25 9007BT1 ............................................................................ 21-25 9007C ................................................................................ 21-22 9007C1 thru 9007C3 ......................................................... 21-32 9007C52A2 thru 9007C68T5.................................. 21-22, 21-23 9007CA0 thru 9007CA9M ...................................... 21-24, 21-25 9007CB31 thru 9007CB36 .................................................. 21-6 9007CB4.............................................................................. 21-6 9007CC1 ............................................................................. 21-6 9007CO3 thru 9007CO7...................................................... 21-6 9007CO52 thru 9007CO68................................................ 21-23 9007CP221 thru 9007CP325 .............................................. 21-6 9007CR53A2 thru 9007CR67T5 ............................ 21-22, 21-23 9007CT10 thru 9007CT13................................................. 21-25 9007CT52 thru 9007CT62................................................. 21-23 9007D ................................................................................ 21-23 9007D1 thru 9007D4 ......................................................... 21-32 9007DA0 thru 9007DA9M ...................................... 21-24, 21-25 9007E ................................................................................ 21-23 9007E4 and 9007E6.......................................................... 21-32 9007EA0 thru 9007EA9M....................................... 21-24, 21-25 9007ED.............................................................................. 21-23 9007F ................................................................................ 21-22 9007F4 thru 9007F6 .......................................................... 21-32 9007FA1 thru 9007FA6 ..................................................... 21-24 9007G................................................................................ 21-22 9007G10............................................................................ 21-32 9007GD ............................................................................. 21-22 9007H ................................................................................ 21-22 9007HA0 thru 9007HA9 .................................................... 21-25 9007J................................................................................. 21-23 9007J1............................................................................... 21-32 9007J2............................................................................... 21-32 9007JKC............................................................................ 21-23 9007K ................................................................................ 21-23 9007K1 .............................................................................. 21-32 9007K2 .............................................................................. 21-32 9007KA1 thru 9007KB15................................................... 21-24 9007KC.............................................................................. 21-23 9007L................................................................................. 21-23 9007LA1 thru 9007LA9...................................................... 21-24 9007MA0 thru 9007MA9M...................................... 21-24, 21-25
2009 Schneider Electric All Rights Reserved
9007ML01S0100 thru 9007ML13S0100 .................... 21-8, 21-9 9007MS01G0100 thru 9007MS13S0100 ................... 21-8, 21-9 9007N................................................................................ 21-22 9007N1 and 9007N2 ......................................................... 21-32 9007R................................................................................ 21-23 9007R16 thru 9007R22 ..................................................... 21-32 9007RA9 thru 9007RA18 .................................................. 21-24 9007S9 .............................................................................. 21-26 9007T10 ............................................................................ 21-22 9007T5 .............................................................................. 21-22 9007TSA1 thru 9007TUD9................................................ 21-31 9007X1 thru 9007Z2 ......................................................... 21-32 9012GAR1 thru 9012GTO4 ................................... 22-1122-13 9013FHG12 thru 9013FYW9 ................................. 22-18, 22-19 9013GHB2 thru 9013GSW3.............................................. 22-20 9016GAR1 thru 9016GVG1 .............................................. 21-17 9036DG2 thru 9036DW31R .............................................. 22-21 9036FG30 ......................................................................... 22-22 9036GG2 thru 9036GW1R................................................ 22-22 9037EG10 thru 9037EW9 ................................................. 22-22 9037HG30 thru 9037HW39............................................... 22-23 9038AG1 thru 9038AW1 ................................................... 22-24 9038CG31 thru 9038CW36............................................... 22-24 9038DG10 thru 9038DW8................................................. 22-25 9049A12 thru 9049A20 .......................................... 22-20, 22-26 9049A26S .............................................................. 22-11, 22-16 9049A52 thru 9049A58 .......................................... 22-20, 22-26 9049A6 .............................................................................. 22-26 9049A60 and 9049A61 ..................................................... 22-22 9049A6A thru 9049AF1..................................................... 22-26 9049EF1 and 9049EF2 ............................... 22-22, 22-25, 22-26 9049ER1 thru 9049ER7 ......................................... 22-25, 22-26 9049HF3 and 9049HF4.......................................... 22-25, 22-26 9049T1 thru 9049T1S ....................................................... 22-26 9049UMS1 ........................................................................ 22-26 9050AO10D thru 9050AO22E........................................... 23-29 9050HO10D thru 9050HO20E .......................................... 23-29 9050JCK11 thru 9050JCK70 ............................................ 23-28 9065CO1 and 9065CO1R ................................................. 16-90 9065DA2 ........................................................................... 16-98 9065FO1L and 9065FO1R................................................ 16-90 9065GA2 ........................................................................... 16-98 9065GO11L and 9065GO11R .......................................... 16-90 9065HA2 ........................................................................... 16-98 9065JA2 ............................................................................ 16-98 9065SDO10 thru 9065SEO15........................................... 16-90 9065SDO4 thru 9065SEO8............................................... 16-90 9065SDO5B1 thru 9065SEO9B2 ...................................... 16-98 9065SF020 thru 9065SFC20 ............................................ 16-91 9065SHA01Y59 and 9065SJA01Y59 ............................... 16-98 9065SM2 ................................................................ 16-90, 16-98 9065SP14 thru 9065ST720............................................... 16-91 9065TJF40 thru 9065TJF160............................................ 16-98 9065TO1 and 9065UO1 .................................................... 16-90 9066RA1 thru 9066W1.................................................... 16-101 9070FB1A thru 9070FB3B ................................................ 14-17 9070FP1............................................................................ 14-17 9070FSC1 thru 9070FSC23.............................................. 14-17 9070LG1 ........................................................................... 14-17 9070MN100G0D1 thru 9070MN500G0D1G13 ...... 14-18, 14-19 9070SDG4 ........................................................................ 14-17 9070SF25A thru 9070SF41B ............................................ 14-17 9070SK1000A2D1 thru 9070SK750G3D1G13 ...... 14-18, 14-19 9070T1000D1 ........................................................ 14-14, 14-15 9070T100D1 thru 9070T75D55 ............................. 14-14, 14-15 9070TF1000D1 thru 9070TF75D50 .................................. 14-16 9070UE7 ........................................................................... 14-17 9080FB1211 thru 9080FB3631R ...................................... 24-19 9080FBDIN3 ..................................................................... 24-19 9080GA6 thru 9080GC6B ...................................... 24-13, 24-14 9080GA6188BC thru 9080GR6204BC ............................. 24-15 9080GCB01 thru 9080GCB70 .......................................... 24-17 9080GD6 thru 9080GG6 ........................................ 24-13, 24-14
i-37
ALPHA-NUMERIC LISTING
9080GH10 thru 9080GH91................................................ 24-16 9080GH103 thru 9080GH710............................................ 24-16 9080GK6 thru 9080GT6B....................................... 24-13, 24-14 9080LB21 thru 9080LB53 ................................................. 24-18 9080LBA161101 thru 9080LBC365212............................. 24-18 9080MH203 thru 9080MH439 ........................................... 24-12 9080MH82 .............................................................. 24-12, 24-16 9080MHA10............................................................ 24-12, 24-16 92251 thru 92451 ................................................................ 3-17 93T144HDIT and 93T145HDIT ........................................... 14-7 9421LC43 thru 9421LC48 ................................................... 8-13 9421LCP48 ......................................................................... 8-13 9421LF1 thru 9421LH8........................................................ 8-13 9421LHP48 ......................................................................... 8-13 9421LHP8 ........................................................................... 8-13 9421LJ1 thru 9421LX7 ........................................................ 8-13 9421NS16 ........................................................................... 8-13 9421NS336 ......................................................................... 8-13 9421NW3 and 9421NW3B .................................................. 8-13 9421V1A30 thru 9421V2W30................................................ 8-3 9422A1 thru 9422A10 ......................................................... 8-17 9422AM2 ............................................................................. 8-24 9422AP1 and 9422AP2 ....................................................... 8-17 9422ARG11 thru 9422ART21 ............................................. 8-23 9422ATCF301 thru 9422ATEN102 ..................................... 8-16 9422ATF11 thru 9422ATF23............................................... 8-17 9422BN1 thru 9422BR1 ...................................................... 8-20 9422BTCF30 thru 9422BTEN10 ......................................... 8-20 9422C1 ................................................................................ 8-24 9422CFA10 thru 9422CFA51 .............................................. 8-20 9422CFAL10 thru 9422CFAL50 .......................................... 8-22 9422CFT10 thru 9422CFT51 .............................................. 8-16 9422CGJ10 thru 9422CLA51 .............................................. 8-20 9422CMP10 thru 9422CSJ504............................................ 8-21 9422D2 thru 9422R2 ........................................................... 9-24 9422RG1 thru 9422RX1 ...................................................... 8-23 9422TC30 and 9422TC33 ...................................... 8-16, 16-124 9422TCF30 thru 9422TEN10C............................................ 8-16 9422TD63........................................................................ 16-124 9422TF1 thru 9422TF3........................................................ 8-17 9422TFB1 thru 9422TFB3................................................... 8-20 9422TG1 and 9422TG2....................................................... 8-17 9423M1 thru 9423M891 ............................................. 8-258-27 9789EPSSTSTRPT thru 9789SER ....................................... 4-4 9991DPG1 thru 9991DPG6.................................. 16-77, 16-103 9991DPSG1 and 9991DPSG2 ........................................ 16-103 9991EN1 ................................................................ 16-9, 16-103 9991FE1 .............................................................................. 19-9 9991KE1 thru 9991KE3....................................................... 16-9 9991LG1.......................................................................... 16-103 9991LXG1 ............................................................ 16-70, 16-103 9991MA1 ......................................................................... 16-102 9991MF1 and 9991MF2 .................................................. 16-103 9991MG1 and 9991MG2 ........................................ 16-9, 16-103 9991MW1 and 9991MW11.............................................. 16-102 9991NPD2003 thru 9991NPJ4100 .................................... 16-81 9991SCA11 thru 9991SGG8 ...................16-70, 16-10216-104 9991UE1 thru 9991UE7 ....................................... 16-103, 23-14 9998DA1 thru 9998DA3 ......................................... 16-77, 16-80 9998DRC1 thru 9998DRC9............................................. 16-116 9998HR2 and 9998HR3 ...................................................... 16-9 9998HW1 and 9998HWA1 .................................................. 16-9 9998IL1 ............................................................................... 16-9 9998ML1 and 9998ML2.......................................... 16-7, 16-116 9998PB14 and 9998PB15 ............................................... 16-116 9998PB2 and 9998PB3 ................................................... 16-116 9998PBV02 thru 9998PBV39 .......................................... 16-115 9998PC177 thru 9998PC338 ............................................ 22-26 9998RA5 thru 9998RA17 ................................................ 16-116 9998RP1 and 9998RP2..................................................... 16-88 9998SG120 thru 9998SG480 .......................................... 16-114 9998SJ1 .......................................................................... 16-116 9998SL2 thru 9998SL33 ................................................. 16-116
i-38
9998SO1 ............................................................................16-80 9998SO31 ................................................... 16-9, 16-80, 16-117 9998SO32 ........................................................................16-117 9998UB01 thru 9998UB14 ...............................................16-117 9998WF thru 9998WH ................................ 16-2716-29, 16-49 9999AC04 ........................................................................16-120 9999AL11 thru 9999AL15 .................................... 16-70, 16-122 9999BLX ............................................................................16-71 9999CPT1D1 and 9999CPT1D3........................................16-40 9999D01 thru 9999D20.................. 16-77, 16-80, 16-89, 16-119 9999DA01 ........................................................................16-120 9999DMB1 .........................................................................16-77 9999DPC1..........................................................................16-77 9999LB0 and 9999LL0.....................................................16-120 9999LLX.............................................................................16-70 9999LUW5 and 9999LUW6 ................................... 16-2716-29 9999LXPB ..........................................................................16-71 9999LXS ............................................................................16-71 9999MB22........................................................................16-120 9999MLPL and 9999MLPS ..............................................16-120 9999MP1 thru 9999MP3 ......................................................16-9 9999PL10 thru 9999PL13G .................................................16-9 9999R10 thru 9999R13........................................ 16-88, 16-119 9999R26 and 9999R27 ...........8-20, 8-23, 16-40, 16-70, 16-124 9999R33 and 9999R34 ......................................................23-29 9999R35 and 9999R36 .................... 8-17, 16-40, 16-70, 16-124 9999R39 thru 9999R46........................................ 16-40, 16-124 9999R47 and 9999R48 .......................................... 8-13, 16-124 9999R6 and 9999R7 ............................................ 16-40, 16-124 9999R8 and 9999R9 .................3-7, 8-17, 16-40, 16-70, 16-124 9999RB34 ........................................................................16-120 9999RLX ............................................................................16-71 9999RR04 ........................................................................16-120 9999S1 thru 9999S5 ........................................................16-124 9999SA10 ............................................................ 16-71, 16-118 9999SA13 ........................................................................16-118 9999SA2 ..........................................................................16-118 9999SA3 .............................................................. 16-71, 16-118 9999SB10 thru 9999SB25 ................................... 16-65, 16-121 9999SB6 thru 9999SB9 ....................................... 16-65, 16-121 9999SBT1 ........................................................................16-121 9999SC2 .............................................................. 16-71, 16-118 9999SC22 ............................................................ 16-71, 16-118 9999SC8 .............................................................. 16-71, 16-118 9999SC9 ..........................................................................16-118 9999SF3 thru 9999SF4....................................................16-121 9999SFR3 and 9999SFR4................................... 16-70, 16-121 9999SG1 thru 9999SG3...................................................16-118 9999SJ2 thru 9999SJ4.....................................................16-124 9999SM1 thru 9999SM9 ..................................................16-123 9999SM10 thru 9999SM13 ..............................................16-123 9999SN1 thru 9999SN4 ....................................... 16-70, 16-122 9999SO11 and 9999SO12...............................................16-123 9999SO4 and 9999SO5....................................... 16-80, 16-122 9999SP12R and 9999SP13R ..........................................16-118 9999SP14R and 9999SP15R .............................. 16-71, 16-118 9999SP28R.......................................................... 16-71, 16-118 9999SP2R and 9999SP3R .................................. 16-71, 16-118 9999SP4R and 9999SP5R ..............................................16-118 9999SR1 thru 9999SR3 ...................................................16-124 9999SR4 and 9999SR5 ......................................... 8-17, 16-124 9999ST1 and 9999ST2 ....................................................16-121 9999SX10 thru 9999SX17 ..................................... 16-9, 16-119 9999T7 .............................................................................16-122 9999TC10 and 9999TC20.........3-7, 8-16, 16-40, 16-70, 16-124 9999TC11 and 9999TC21................ 8-16, 16-40, 16-70, 16-124 9999WCX11 thru 9999WLX01.................... 16-2716-29, 16-49 9999WX11 .................................................. 16-2716-29, 16-49 9T2F thru 9T75F ........................................................ 14-4, 14-5
ALPHA-NUMERIC LISTING
AWG kcmil
Types TW, UF
Types TW, UF
AWG kcmil
Copper 18 16 14j 12j 10j 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 800 900 1000 1250 1500 1750 2000 .... .... 20 25 30 40 55 70 85 95 110 125 145 165 195 215 240 260 280 320 355 385 400 410 435 455 495 520 545 560 .... .... 20 25 35 50 65 85 100 115 130 150 175 200 230 255 285 310 335 380 420 460 475 490 520 545 590 625 650 665 14 18 25 30 40 55 75 95 110 130 150 170 195 225 260 290 320 350 380 430 475 520 535 555 585 615 665 705 735 750 .... .... .... 20 25 30 40 55 65 75 85 100 115 130 150 170 190 210 225 260 285 310 320 330 355 375 405 435 455 470
Aluminum or Copper-Clad Aluminum .... .... .... 20 30 40 50 65 75 90 100 120 135 155 180 205 230 250 270 310 340 375 385 395 425 445 485 520 545 560 .... .... .... 25 35 45 60 75 85 100 115 135 150 175 205 230 255 280 305 350 385 420 435 450 480 500 545 585 615 630 .... .... .... 12j 10j 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 800 900 1000 1250 1500 1750 2000
Correction Factors
Ambient Temp. C 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60 61-70 71-80 j See Section 240.4 (D). For ambient temperatures other than 30C (86F), multiply the allowable ampacities shown above by the appropriate factor shown below. 1.08 1.00 .91 .82 .71 .58 .41 .... .... .... 1.05 1.00 .94 .88 .82 .75 .67 .58 .33 .... 1.04 1.00 .96 .91 .87 .82 .76 .71 .58 .41 1.08 1.00 .91 .82 .71 .58 .41 .... .... .... 1.05 1.00 .94 .88 .82 .75 .67 .58 .33 .... 1.04 1.00 .96 .91 .87 .82 .76 .71 .58 .41 Ambient Temp. F 70-77 78-86 87-95 96-104 105-113 114-122 123-131 132.140 141-158 159-176
Ratings for 120/240 volts, 3-Wire, Single-Phase Dwelling Services See NEC Table 310.15 (B)(6) These are permitted ratings for Dwelling Unit service and feeder conductors which carry the total load of the dwelling.
Rating (amps) Copper Aluminum 100 4 2 110 3 1 125 2 1/0 150 1 2/0 175 1/0 3/0 200 2/0 4/0 225 3/0 250 4/0 300 350 400
250 kcmil 300 kcmil 350 kcmil 500 kcmil 600 kcmil
NEC 240.4 (D) Small Conductors Unless specifically permitted in (E) through (G), the overcurrent protection shall not exceed 15 amperes for #14 AWG, 20 amperes for #12 AWG, and 30 amperes for #10 AWG copper; or 15 amperes for #12 AWG and 25 amperes for #10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. NEC 210.19 Conductors Minimum Ampacity and Size The branch-circuit rating shall not be less than the noncontinuous load plus 125 percent of the continuous load. (See Exception for 100% rated devices) NEC 210.20 (A) Continuous and Noncontinuous Loads Where a branch-circuit supplies continuous loads or any combination of continuous and noncontinuous loads, the rating of the overcurrent device shall not be less than the noncontinuous load plus 125 percent of the continuous load. (See Exception for 100% rated devices) NEC 430.22 (A) Single Motor Circuit Conductors Branch-circuit conductors supplying a single motor shall have an ampacity not less than 125 percent of the motors full-load current rating. (See Exceptions)
Adjustment Factors See NEC Table 310.15 (B)(2)(a) Where the number of current-carrying conductors in a raceway or cable exceeds three, the allowable ampacities shall be reduced as shown in the following table:
Number of Current-Carrying Conductors 4 through 6 7 through 9 10 through 20 21 through 30 31 through 40 41 and Above See exceptions to NEC 310.15 (B)(2). Percent of Values in Tables as Adjusted for Ambient Temperature as Necessary 80 70 50 45 40 35
NEC 240.4 Protection of Conductors Conductors, other than flexible cords and fixture wires, shall be protected against overcurrent in accordance with their ampacities specified in NEC 310.15, unless otherwise permitted or required in parts (A) through (G) of NEC 240.4.
2007 Schneider Electric All Rights Reserved 3/07
www.schneider-electric.us