PLAN NORTH MECCA

TRUE NORTH

KEYPLAN

TRUE NORTH MECCA

0311 - 087

DRAWING NUMBER: 1861B-

A3

B3

C3

D3

1.8

2.4

2.6

2.8

3.2

3.5

3.8

4.2

4.5 4.6 4.7

5.2

5.6

7.5

8
A2 B2 C2 D2

A1

B1

C1

D1

GENERAL SHEET NOTES:


1. SEE SHEET 0301-004 AND 0301-005 FOR ABBREVIATIONS, TYPICAL INFO, INDICATION OF MATERIALS, SYMBOLS, GENERAL NOTES AND PROJECT INFORMATION. 2. SEE SHEET 0362-001 FOR MOUNTING HEIGHTS 3. SEE SHEET 0409-001 TO 0409-003 FOR CASEWORK KEYS AND CASEWORK FINISHES AND GENERAL NOTES 4. W1 AND W2 FRAME TYPES, SEE FRAME TYPES SHEET 0386-001. 5. SEE SHEET 0410-012 DETAILS 4,5 AND SHEET 0412-002 DETAIL 2. 6. SEE SHEET 0385-001 TO 385-004 FOR PARTITION TYPES 7. SEE SHEET 0418-002 FOR FLOOR DRAIN DETAILS. PROVIDE FIRE STOPPING TO MAINTAIN FIRE/SMOKE RATED CONDITIONS. 8. SEE SHEET 0416-001 FOR CONCRETE INFILL DETAIL AT FLOOR PLUMBING OPENINGS CONTRACTOR SHALL PROVIDE PIPE SLEEVE(S) AND FIRE STOPPING SYSTEM TO MAINTAIN FIRE/SMOKE RATED CONDITIONS. 9. SEE SHEET SERIES 0409 FOR HEADWALL ELEVATIONS, SECTIONS AND DETAILS.

7 7.2

10800

REMOVABLE PANELS FOR BINDING

KEO ACTION
A - APPROVED B - APPROVED WITH COMMENTS MATCH LINE A3 MATCH LINE B3 C - NOT APPROVED/REJECTED D - COMMENTED AND RESUBMIT E - SEE RESPONSE ENG. DATE: R.E. DATE:

8
10800

1' 2' 3' 4'

Checking is only with the design concept of project and compliance with the information given in the contract documents. Contractor is responsible for dimensions to be confirmed and corrected at the job site for the information that pertains solely to the fabrication process or to techniques of construction and the co-ordination of the work of all trades.

Transmittal No. 1861B/BP#9/TS/OHL-CON/KEO/

DATE:

Certified for co-ordination

Q
MECHANICAL
H5-94001
S4 S4 S4

DEPARTMENT HVAC PL & FF ELECTRICAL

COMPANY KVC KVC KVC

SIGNATURE

DATE

MECH SHAFT

S4

PROVIDE FLOATING FLOOR SYSTEM (FFS-01) AT MECHANICAL AND PTS ROOMS. SEE DETAILS ON SHEET 0416-001 AND MANUFACTURER DETAIL LITERATURE. PROVIDE 100mm HOUSE KEEPING PAD ON (FFS-01) FOR ALL MEP EQUIPMENT COORDINATE LOCATION AND SIZE OF ALL MEP EQUIPMENT PADS WITH MEP CONTRACTOR SEE DETAILS ON SHEET 0416-001. PROVIDE 200mm(H) x 150mm(W) CONC CURB ON ALL SIDES AT FLOOR OPENINGS AND WRAP WATER PROOFING MEMBRANE (TC-01) UP CURB 100mm MIN.
UP

TEL/BAS/FP MEP CIVIL STRUCTURAL LEAD ARCHITECT HOARE LEA PARSONS GES ELLERBE BECKET

10800

REFERENCE DRAWINGS
DRAWING NO. TITLE

9
UP

ALL FLOOR PENETRATIONS SHALL BE WATER TIGHT CONSTRUCTION. 2185


R6 R6 F4 R6 TD6 R6 F4 R6

0329-038

ON CALL
H5-70012

F2 F2

F2 TB4

700

P
MATCH LINE A3 MATCH LINE A2

R6

P
BOLD LINE DENOTES HOLD FOR AGV VENDOR INFO

TF4 TB4

TOILET ON CALL
H5-70012T

TOILET STUDENT/M
H5-70096T

80 0

C4

4'

TOILET TB4 STUDENT/F


H5-70033T

PRAYER/M
TB4

D4

H5-70019

LOCKER STUDENT CORRIDOR


H5-70013
1408 9480 1320 6200 1320 9480 1408 9392

SERVICE ELEVATOR
V-2 1
0348 - 009

H5-70033

AGV ELEVATOR
V-3
5400 5400

AGV CART ELEVATOR LOBBY


H5-70022

DRAWINGS
8
RE-ISSUED FOR COMMENTS (DD) RE-ISSUED FOR COMMENTS (DD/GA) D1 RE-ISUED FOR COMMENTS D0 ISSUED FOR COMMENTS REV. DESCRIPTION D3 D2 01/11/10 13/08/10 24/10/09 13/06/09 DATE
Executive Architect

3'

2'

1'

1.8

2 (H)2

2.4

2.6

2.8

3.2

3.5

3.8

4.2

4.5 4.6 4.7

5.2

5.6

7.5

JH JH

SC SC

EB EB

DD DD

JH SC EB DD SH CL EB SD DWN CHKD APPD APPD

E
Ellerbe Becket, Inc. Main Contractor Sub Contractor

800 LaSalle Avenue Minneapolis, Minnesota 55402 612 376 2000 612 376 2271 Fax http://www.ellerbebecket.com

FIFTH LEVEL - FLOOR PLAN AREA A3 1 : 100


TITLE

BP#9 - SIDRA MEDICAL & RESEARCH CTR HOSPITAL BUILDING FIFTH LEVEL - FLOOR PLAN AREA A3

CAD FILENAME:

SCALE 1:100 0 1000 2000 4000 10000

THIS IS A REVIT DRAWING AND MUST NOT BE ALTERED MANUALLY DRAWING NUMBER: SCALE: 1 : 100 ORIG. DWG SIZE: A0 REV.

1861B - 0311

Sht.

087

Con't. on

088

D3