Thread Starter: Shahid muhammed Started: 8/1/2011 11:53 AM Replies: 2 Previous thread Next thread Disable Notification Page 1 of 1 (3 items) 8/1/2011, 11:53 AM
Shahid muhammed

(0) Hai,

Joined 5/3/2011 Last visit: 8/1/2011 Posts: 1 Rating: (0)

This is kind of problem i faced while trying to do the program transfer in the 802D, the problem was some extra charecters are getting added up in the program received (Please find the Program attached which I have received from the machine.). Since some extra characters are getting added up machine is note receiving the program back (I have remove the extra characters and then send it back but thats some thing I don't want to do). Please help me on this. Thanks in advance

Attachment:
Private message

1000.zip (7 Downloads)
Edit Reply Quote Top

Inform Moderators

8/1/2011, 2:50 PM
Pee El Sea

(0) Rate Thank Hi,

Joined 1/19/2008 Last visit: 8/1/2011 Posts: 183 Rating: (6) Private message

I think you are outputting as a binary backup file Output in punch tape format with cr Pee
Inform Moderators Reply Quote Top

8/1/2011, 4:38 PM
rantu

(0) Rate Thank Hi

Joined 12/21/2005 Last visit: 8/1/2011 Posts: 19 Rating: (0)

Set Punch tape format in PC as well as CNC. Then you will get the exact program with out extra characters. The setting in CNC you can find in Press Shift key hold it & press Alarm key the Press Data I/O --> Settings. here you can change it. For PC side in WINPCIN you will find RS232 Settings. Hope this will solve your problem Rantu

1 of 2

8/2/2011 10:09 AM

Extra Characters While receiving program from Sinumerik 802D through...

https://www.automation.siemens.com/ww/forum/guests/PostShow.aspx?P...

Private message

Inform Moderators

Reply Quote Top

Page 1 of 1 (3 items) Actions Copy Link To conference New post

Siemens AG 2010 - Corporate Information - Privacy Policy - Terms of Use

2 of 2

8/2/2011 10:09 AM

Вам также может понравиться