Вы находитесь на странице: 1из 1

(0) Axial Duct: Comprising of one (1) rectnagular duct, one (1) transition piece from circular to rectangular,

one (1) dump tube connection

Dump Steam connection

Atmospheric Relief Valve

Rupture Disk

(6) Drain Header

(6) Flash Tank

Leyend (0) Steam Duct (1) Main Condenser (2) Condensate pumps (3) Vacuum Unit (4) Level Control valves (5) Gland Steam Condenser (6) Flash Tank and Drain Header (8) Interconnecting Piping
(1) Main Condenser: Axial Steam Entry Divided water boxes, two pass-design, flat water boxes covers at both ends

(5) Gland Steam Condenser

(3) Vacuum Unit: Steam-jet Ejector type, comprising of 2x100% 2-stages holding eyectors + 1 hogging eyector with silencer + 1 x 100 % inter-after condenser + valves + traps + piping; all arranged in a common base frame

(8) Interconnecting Piping: (4) Level Control Valve: Return condensate Hotwell

(4) Level Control Valve: Overboard (2) Condensate Pumps: 3 x 100% Motor driven mounted in baseframes

(8) Interconnecting Piping