specimen using sine bar. INSTRUMENTS REQUIRED: >. SURFACE PLATE > . SLIP GAUGE > . DEFELECTO METER SPECIFICATION: Dial Gauge: L.C=--------mm Slip Gauge: Range =-------------mm
PROCEDURE: > . Place the job on the sine bar such that the angle of the face which has to be measured is placed upwards. > .A gauge block of a slip gauge having small values is placed under one of the cylinder such that the taper face is made parallel to the surface plate. > . Using deflect meter, deflection reading is noted down at the end of the taper face. > .Check whether the two readings are equal. >. If the readings are not equal then add or subtract the values of slip gauge block. > . If the readings are equal then the taper face is said to be in the surface plate. > . After making the taper face use the height "h" can be calculated by summing the slip gauges > .The angle of taper can be calculated as Sin29=h/L RESULT: Thus the unknown angle is determined by using sine bar.