Вы находитесь на странице: 1из 86

FM/BM 1xxx/2xxx

FM 1000 MOVE Z-AXIS AS DOWN AS POSSBLE Cause: Effect: Remedy: Note: The brake test of Z-axis during teststop was not successful

FM 1001 Z-AXIS BRAKE TEST FAILED Cause: Effect: Remedy: Note: The brake test of Z-axis during teststop was not successful

FM 1002 CNC NOT READY "F1.7" Cause: Effect: Remedy: Note: The NC is not ready The Machine can not be turned ON See detailed Alarmlist (also Fanuc)

FM 1003 BATTERY STATUS LOW Cause: Effect: Remedy: Note: The Battery status is low Non While machine is turned ON replace battery DO NOT TURN OFF MACHINE - LOOSE REFERENCE POINT

FM 1004 FUSE TRIPPED "F10" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

Version F_02 / 13.08.2008 WeK 1 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1005 FUSE TRIPPED "F11" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1006 FUSE TRIPPED "F12" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1007 FUSE TRIPPED "F36" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1008 FUSE TRIPPED "F40" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

Version F_02 / 13.08.2008 WeK 2 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1009 FUSE TRIPPED "F44" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1010 FUSE TRIPPED "F32" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1011 FUSE TRIPPED "FA10" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1012 FUSE TRIPPED "FA1" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

Version F_02 / 13.08.2008 WeK 3 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1013 FUSE TRIPPED "FA8" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1014 FUSE TRIPPED "FA12" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1015 FUSE TRIPPED "FA16" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1016 FUSE TRIPPED "FA32" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

Version F_02 / 13.08.2008 WeK 4 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1017 FUSE TRIPPED "FA34" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1018 FUSE TRIPPED "FA36" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1019 FUSE TRIPPED "FA40" Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

FM 1020 FUSE TRIPPED Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock Insert fuse Check circuit / input

Version F_02 / 13.08.2008 WeK 5 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1021 MAX END POSITION AXES "" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1022 OVLD C/LUBE "ZS-Q12" Cause: Effect: Remedy: Note: Over-current trigger for lubrication has engaged Feed stop / spindle stop Start lock Check the circuits of the lubrication unit (motor may be blocked) Switch the trigger into the circuit

FM 1023 OVLD COOLANT "S271" Cause: Effect: Remedy: Note: Over-current trigger for coolant system has engaged Feed stop / spindle stop Start lock Check currents Switch the trigger into the circuit Compact system: all triggers for coolant. Systems with additional container (ASI): auxiliary drives except for coolant pumps (external/internal cooling)

FM 1024 OVLD HYDRAULIC "HY-Q10" Cause: Effect: Remedy: Note: Over-current trigger for hydraulic system has engaged Feed stop / spindle stop Start lock Check the circuits of the hydraulic unit Switch the trigger into the circuit

Version F_02 / 13.08.2008 WeK 6 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1025 OVLD HEAT EXCH "Q14/16" Cause: Effect: Remedy: Note: Over-current trigger for cooling system has engaged Feed stop / spindle stop Start lock

FM 1026 OVLD EXHAUSTSY "Q18" Cause: Effect: Remedy: Note: Over-current trigger for air exhaust system has engaged Feed stop / spindle stop Start lock Check the circuits Switch the trigger into the circuit

FM 1027 NO 24V FROM SW "S270" Cause: Effect: Remedy: Note: Coolant: 24 V power supply (outputs) not reporting Feed stop / spindle stop Start lock Check 24-V power supply Signal is only available if a coolant is turned on. Switch cabinet on the KLM

FM 1029 SERVO NOT RDY "SA#2" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 7 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1030 MAIN PWR MODUL NOT RDY "CX3:3" Cause: Effect: Remedy: Note: Drive train: supply/ monitoring module 1 not reporting ready for operation Feed stop / spindle stop Start lock Emergency STOP + RESET, then delete error(s) Look for other alarms

FM 1031 MAIN PWR MODUL NOT RDY Cause: Effect: Remedy: Note: Drive train: supply/ monitoring module 2 not reporting ready for operation Feed stop / spindle stop Start lock

FM 1032 ALARM SPINDLE 1 "ALMA" Cause: Effect: Remedy: Note: Fanuc Alarm Spindle 1 occured Feed stop / spindle stop Start lock RESET or turn OFF and ON the machine For further information see Fanuc "Maintance manual"

FM 1033 ALARM SPINDLE 2 "ALMB" Cause: Effect: Remedy: Note: Fanuc Alarm Spindle 2 occured Feed stop / spindle stop Start lock RESET or turn OFF and ON the machine For further information see Fanuc "Maintance manual"

Version F_02 / 13.08.2008 WeK 8 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1034 SERVO NOT RDY "SA" Cause: Effect: Remedy: Note: The Servo Modul is not ready Feed stop / spindle stop Start lock

FM 1035 POLE DETECT.SPDL NOT PROCESSED Cause: Effect: Remedy: Note: Pole detection on synchron spindle is not processed Feed stop / spindle stop Start lock

FM 1036 POLE DETECT.AXIS NOT PROCESSED Cause: Effect: Remedy: Note: Pole detection on ETEL axis is not processed Feed stop / spindle stop Start lock

FM 1037 BKW COOLER NOT RDY "S150" Cause: Effect: Remedy: Note: Cooling unit not ready for operation Feed stop / spindle stop Start lock JOG + error delete key Note any additional messages (check filling level of water)

Version F_02 / 13.08.2008 WeK 9 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1038 ELEC.CAB-COOLER NOT RDY Cause: Effect: Remedy: Note: Electrical cabinet cooler not ready for operation Feed stop / spindle stop Start lock

FM 1039 HYDR OIL MIN LEVEL "HY-B141" Cause: Effect: Remedy: Note: Hydraulics: oil level low Feed stop / spindle stop Start lock Fill up hydraulic oil

FM 1040 NO SYSTM HYDR PRS "HY-B130" Cause: Effect: Remedy: Note: Hydraulics: system pressure monitoring has engaged Feed stop / spindle stop Start lock Check hydraulics

FM 1041 HYDR RETURN FILTR DIRTY Cause: Effect: Remedy: Note: Hydraulics: return filter dirty Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 10 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1042 OVRHEATED HYDR TEMP "HY-B132" Cause: Effect: Remedy: Note: Hydraulics: temperature monitoring has engaged Feed stop / spindle stop Start lock Cool off hydraulics, find out reason for heating up

FM 1043 HYD FILTER DIRTY Cause: Effect: Remedy: Note: Hydraulics: filter dirty Feed stop / spindle stop Start lock Replace filter

FM 1044 MAGAZIN BALANCE N.OK "S416/417" Cause: Effect: Remedy: Note: Magazine has engaged out of neutral position Feed stop / spindle stop Start lock

FM 1045 TANKLOAD PRS NOT REACHED Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 11 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1046 NO SYSTM PNEUM PRS "PN-B122" Cause: Effect: Remedy: Note: Pneumatic system pressure has dropped Feed stop / spindle stop Start lock Check air supply Check pressure switch

FM 1048 MAINTENANCE DOOR NOT CLOSED Cause: Effect: Remedy: Note: Maintenance door is not closed Switch from maintenance door has no respond Feed stop / spindle stop Start lock Press "DELETE FAULT MESSAGE" button Check door switch

FM 1049 SETUP DOOR N.LOCKED "MA-7S1-4" Cause: Effect: Remedy: Note: Interlock switch for partition wall is not locked Feed stop / spindle stop Start lock Close partition wall, check interlock switch 2-slot machines only

FM 1050 LOAD DOOR N.UNLOCKED "MA-S401" Cause: Effect: Remedy: Note: Interlock switch for loading door is not unlocked Feed stop / spindle stop Start lock Interlock magnet feedback, loading door missing

Version F_02 / 13.08.2008 WeK 12 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1051 MAG DOOR N.LOCKED "MA-S411" Cause: Effect: Remedy: Note: Interlock switch for magazine door is not locked Feed stop / spindle stop Start lock Close magazine loading door, check lock switch of magazine loading door

FM 1052 LOAD DOOR N.OPENED "E363" Cause: Effect: Remedy: Note: Landert drive for loading door has error upon opening Feed stop / spindle stop Start lock Check Landert/loading door No loading enable with robot operation (loading from above)

FM 1053 LOAD DOOR N.LOCKED "MA-S401" Cause: Effect: Remedy: Note: Interlock switch for loading door is not locked Feed stop / spindle stop Start lock Check covering interlock

FM 1054 LOAD DOOR N.CALIBRATED "E364" Cause: Effect: Remedy: Landert drive for loading door is not calibrated Feed stop / spindle stop Start lock Close and open loading door with keys on control panel. Check to ensure input door calibrated Check Landert unit (mechanics, belt) Note: Do not activate the counter direction directly after opening / closing; this will interrupt the calibration process in some circumstances (wait 2-3 sec.)

Version F_02 / 13.08.2008 WeK 13 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1055 SAFETY SWITCH SIDE PAN Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1056 SAFETY SWITCH SIDE PAN Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1057 C/LUBE PRESSURE "ZS-B031" Cause: Effect: Remedy: Note: Lubrication pressure of central lubrication reporting incorrect Feed stop / spindle stop Start lock Check lines and pressure switch of central lubrication

FM 1061 SP/LUBE OIL PRESS. "ZS-B033" Cause: Effect: Remedy: Note: Grease pressure of spindle lubrication reporting wrong Feed stop / spindle stop Start lock Check lines and pressure switch for lubrication pressure in spindle lubrication

Version F_02 / 13.08.2008 WeK 14 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1062 SP/LUBE PNEU.PRESS "ZS-B032" Cause: Effect: Remedy: Note: Pneumatic pressure of spindle lubrication reporting wrong Feed stop / spindle stop Start lock Check lines and pressure switch for pneumatic pressure in spindle lubrication

FM 1064 FUSE TRIPPED Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock

FM 1065 FUSE TRIPPED Cause: Effect: Remedy: Note: Fuse has been tripped Feed stop / spindle stop Start lock

FM 1072 FAULT PROG NR CONVERSION Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 15 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1073 FAULT TRANSFER PROG NR TO CNC Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1080 COOLANT MIN LEVEL "S282" Cause: Effect: Remedy: Note: Coolant: clean water floater switch reporting MIN Feed stop / spindle stop Start lock Fill with clean water, check floater switch

FM 1081 OVERFLOW COOLANT SYSTEM "S291" Cause: Effect: Remedy: Note: Coolant: MAX clean water floater switch for belt filter system has engaged Feed stop / spindle stop Start lock Check MAX clean water floater switch, drain out clean water

FM 1082 COOLANT MAX LEVEL "S280" Cause: Effect: Remedy: Note: Coolant: swarf conveyor floater switch reporting MAX Feed stop / spindle stop Start lock Check lifting pump and floater switch

Version F_02 / 13.08.2008 WeK 16 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1083 CLEAN WATR MIN TURBO "S282" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1084 MUDY WATR MAX TURBO "S291" Cause: Effect: Remedy: Note: Coolant: MAX dirty water floater switch for turbo filter has engaged Feed stop / spindle stop Start lock Check dirty water floater switch, drain out dirty water

FM 1085 PROGR COOLANT PRESSURE >70 Cause: Effect: Remedy: Note: Coolant pressure was programmed higher than 70 bar Feed stop / spindle stop Start lock Check NC program #1132 < 70

FM 1086 MUDY WATR MIN TURBO "S303" Cause: Effect: Remedy: Note: Coolant: MIN dirty water floater switch for turbo filter has engaged Feed stop / spindle stop Start lock Check MIN floater switch, refill with water

Version F_02 / 13.08.2008 WeK 17 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1087 GREASE LUBRICATN MIN "B153" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1088 Q POSITIONING PMC N.FINISHED Cause: Effect: Remedy: Note: PMC positioning of rotary axis could not finished Feed stop / spindle stop Start lock

FM 1089 PAIRCHEK Q-AXIS "S070/071" Cause: Effect: Remedy: Note: Both limit switches of Q axis reporting (raised/lowered) Feed stop / spindle stop Start lock Check proximity switch

FM 1090 Q-AXIS N.ON 0 DEG "S390" Cause: Effect: Remedy: Note: Software cam does not match travel movement Feed stop / spindle stop Start lock Check soft cam(s) By authorized personnel only

Version F_02 / 13.08.2008 WeK 18 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1091 Q-AXIS N.ON 180 DEG "S391" Cause: Effect: Remedy: Note: Software cam does not match travel movement Feed stop / spindle stop Start lock Check soft cam(s) By authorized personnel only

FM 1092 Q-AXIS N.RAISED "S071" Cause: Effect: Remedy: Note: Limit switch for swivel table not reporting raised Feed stop / spindle stop Start lock Check proximity switch

FM 1093 Q-AXIS N.LOCKED "S070" Cause: Effect: Remedy: Note: Limit switch for swivel table not reporting lowered Feed stop / spindle stop Start lock Check proximity switch

FM 1095 Q-AXIS SIGNAL 0/180 (SOFTWARE) Cause: Effect: Remedy: Note: Rotary table is out of software limit switches Feed stop / spindle stop Start lock Check softcam positions for rotary table Move rotary table in singlemovement to defined position

Version F_02 / 13.08.2008 WeK 19 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1096 Q-AXIS NOT ON 0 DEGREE Cause: Effect: Remedy: Note: Rotary table is not on 0 degree Feed stop / spindle stop Start lock Check softcam positions for rotary table 0 degree Move rotary table in singlemovement to defined position

FM 1097 Q-AXIS NOT ON 180 DEGREE Cause: Effect: Remedy: Note: Rotary table is not on 180 degree Feed stop / spindle stop Start lock Check softcam positions for rotary table 180 degree Move rotary table in singlemovement to defined position

FM 1098 Q-AXIS N.IN DEFIND POSITION Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1100 PLEASE EXECUTE SAFE TEST Cause: Effect: Remedy: Note: A teststop has to executed fter Power ON or after 24h runtime Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 20 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1101 CNC ALARM PATH 1 Cause: Effect: Remedy: Note: PMC Alarm in Path 1 Feed stop / spindle stop Start lock

FM 1102 CNC ALARM PATH 2 Cause: Effect: Remedy: Note: PMC Alarm in Path 2 Feed stop / spindle stop Start lock

FM 1103 DCS ALARM Cause: Effect: Remedy: Note: PMC Alarm in Path Dual Check Safety Feed stop / spindle stop Start lock

FM 1104 A-POSITIONING PMC N.FINISHED Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 21 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1105 A-AXIS NOT RELEASED "HY-B101" Cause: Effect: Remedy: Note: Axis lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for A axis

FM 1106 A-AXIS NOT LOCKED "HY-B100" Cause: Effect: Remedy: Note: Axis lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for A axis

FM 1107 A-AXIS MOTOR OVERTEMP "X380" Cause: Effect: Remedy: Note: Axis has over temperature Feed stop / spindle stop Start lock

FM 1108 A-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position Feed stop / spindle stop Start lock Put A axis in homeposition Check soft cams for homeposition

Version F_02 / 13.08.2008 WeK 22 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1109 A-COUNTERB.N.RELEASD "HY-B103" Cause: Effect: Remedy: Note: Axis counterbearing lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for A counterbearing

FM 1110 A-COUNTERB.NOT LOCKD "HY-B102" Cause: Effect: Remedy: Note: Axis counterbearing lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for A counterbearing

FM 1113 U-POSITIONING PMC N.FINISHED Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock

FM 1114 U-AXIS NOT RELEASED "HY-B111" Cause: Effect: Remedy: Note: Axis lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

Version F_02 / 13.08.2008 WeK 23 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1115 U-AXIS NOT LOCKED "HY-B110" Cause: Effect: Remedy: Note: Axis lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

FM 1116 U-AXIS MOTOR OVERTEMP "X381" Cause: Effect: Remedy: Note: Axis has over temperature Feed stop / spindle stop Start lock

FM 1117 U-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position Feed stop / spindle stop Start lock Put A axis in homeposition Check soft cams for homeposition

FM 1118 U-COUNTERB.N.RELEASD "HY-B113" Cause: Effect: Remedy: Note: Axis counterbearing lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for U counterbearing

Version F_02 / 13.08.2008 WeK 24 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1119 U-COUNTERB.N.LOCKED "HY-B112" Cause: Effect: Remedy: Note: Axis counterbearing lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for U counterbearing

FM 1120 MAG POSITIONING NOT FINISHD Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock Try again / if necessary Reset / machine Off-On Watch for additional NC alarms and report them to the SW customer service if necessary

FM 1121 MAG POSITION NOT FOUND Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1123 FAULT COUNTING MODE MAG Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 25 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1127 SPINDEL TOOL NOT CLMPED CORRECT Cause: Effect: Remedy: Note: Spidle tool ist not correctly tightened Feed stop / spindle stop Start lock Tool in spindle Check tool clamping device See operating instructions

FM 1128 SPI 1 (A/D CONV) NO SIGNAL Cause: Effect: Remedy: Note: Analog digital converter for tool clamping device 1: no signal from Fanuc module Feed stop / spindle stop Start lock Check adapter for tool clamping device / check analog module By authorized personnel only

FM 1129 TL-CLMP SPI 1 NOT RELEASED Cause: Effect: Remedy: Note: Tool clamping device 1: unclamping error Feed stop / spindle stop Start lock Check tool / check tool clamping device signals See operating instructions and SW diagnostics

FM 1130 SPI 3 (A/D CONV) NO SIGNAL Cause: Effect: Remedy: Note: Analog digital converter for tool clamping device 3: no signal from Fanuc module Feed stop / spindle stop Start lock Check adapter for tool clamping device / check analog module By authorized personnel only

Version F_02 / 13.08.2008 WeK 26 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1131 TL-CLMP SPI 3 NOT RELEASED Cause: Effect: Remedy: Note: Tool clamping device 3: unclamping error Feed stop / spindle stop Start lock Check tool / check tool clamping device signals See operating instructions and SW diagnostics

FM 1133 LEAK DETECTION SP1 Cause: Effect: Remedy: Note: Spindle 1: leeking detection has engaged Feed stop / spindle stop Start lock

FM 1134 LEAK DETECTION SP3 Cause: Effect: Remedy: Note: Spindle 3: leeking detection has engaged Feed stop / spindle stop Start lock

FM 1136 SPI 2 (A/D CONV) NO SIGNAL Cause: Effect: Remedy: Note: Analog digital converter for tool clamping device 2: no signal from Fanuc module Feed stop / spindle stop Start lock Check adapter for tool clamping device / check analog module By authorized personnel only

Version F_02 / 13.08.2008 WeK 27 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1137 TL-CLMP SPI 2 NOT RELEASED Cause: Effect: Remedy: Note: Tool clamping device 2: unclamping error Feed stop / spindle stop Start lock Check tool / check tool clamping device signals See operating instructions and SW diagnostics

FM 1138 SPI 4 (A/D CONV) NO SIGNAL Cause: Effect: Remedy: Note: Analog digital converter for tool clamping device 4: no signal from Fanuc module Feed stop / spindle stop Start lock Check adapter for tool clamping device / check analog module By authorized personnel only

FM 1139 TL-CLMP SPI 4 NOT RELEASED Cause: Effect: Remedy: Note: Tool clamping device 4: unclamping error Feed stop / spindle stop Start lock Check tool / check tool clamping device signals See operating instructions and SW diagnostics

FM 1141 LEAK DETECTION.SP2 Cause: Effect: Remedy: Note: Spindle 2: leeking detection has engaged Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 28 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1142 LEAK DETECTION.SP4 Cause: Effect: Remedy: Note: Spindle 4: leeking detection has engaged Feed stop / spindle stop Start lock

FM 1144 PAIRCHK MAG SP 1 "PN-S010/011" Cause: Effect: Remedy: Note: Both limit switches of tool magazine 1 interlock are unlocked/locked have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1145 PAIRCHK MAG SP 2 "PN-S012/013" Cause: Effect: Remedy: Note: Both limit switches of tool magazine 2 interlock are unlocked/locked have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1147 PAIRCHK MAG-LOAD "PN-S042/043" Cause: Effect: Remedy: Note: Both limit switches of loading slot interlock are unlocked/locked have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 29 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1148 PAIRCHK MAG-LOAD 2 Cause: Effect: Remedy: Note: Both limit switches of loading slot interlock are unlocked/locked have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1149 PAIRCHK MAG-COVR "PN-S020/021" Cause: Effect: Remedy: Note: Both limit switches of the left magazine covering OPEN/CLOSED have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1150 PAIRCHK MAG-CVR 2 "PN-S022/023" Cause: Effect: Remedy: Note: Both limit switches of the right magazine covering OPEN/CLOSED have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1151 PAIRCHK MAG-COVR Cause: Effect: Remedy: Note: Both limit switches of the magazine forward / return have engaged Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 30 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1152 TL POS 1 NOT UNLOCKD "PN-S010" Cause: Effect: Remedy: Note: Limit switch tool slot 1 is not unlocked Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1153 TL POS 2 NOT UNLOCKD "PN-S012" Cause: Effect: Remedy: Note: Limit switch tool slot 2 is not unlocked Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1154 TL POS 1 NOT LOCKD "PN-S011" Cause: Effect: Remedy: Note: Limit switch tool slot 1 is not locked Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1155 TL POS 2 NOT LOCKD "PN-S013" Cause: Effect: Remedy: Note: Limit switch tool slot 2 is not locked Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 31 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1156 LOAD PL. N.UNLOCKD "PN-S042" Cause: Effect: Remedy: Note: Limit switch loading slot is not unlocked Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1157 LOAD PL.2 N.UNLOCKD Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1158 LOAD PL. N.LOCKD "PN-S043" Cause: Effect: Remedy: Note: Limit switch loading slot is not locked Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1159 LOAD PL. 2 N.LOCKD Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 32 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1160 MAG CVR NOT OPEN "PN-S020/022" Cause: Effect: Remedy: Note: Limit switch for magazine covering is not open Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1161 MAG CVR N.CLOSED "PN-S021/023" Cause: Effect: Remedy: Note: Limit switch for magazine covering is not closed Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1162 MAG N. ADVANCED Cause: Effect: Remedy: Note: Limit switch for magazine holder is not advanced Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

FM 1163 MAG N. RETURNED Cause: Effect: Remedy: Note: Limit switch for magazine holder is not retracted Feed stop / spindle stop Start lock Check proximity switch See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 33 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1164 TIMEOUT TOOLCHANGER Cause: Effect: Remedy: Tool change was not completed within the specified time frame Feed stop / spindle stop Start lock Move tool change to basic setting, basic setting key Move tool change to basic setting via single movement. Check temporary storage of tool management Note: For basic setting see the operating instructions

FM 1165 MAGAZINE LIST NOT EMPTY Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1168 NO TABLE CHOOSEN Cause: Effect: Remedy: Note: Either Table 1 or Table 2 is selected Feed stop / spindle stop Start lock Select a table in the SW-Menue (CUSTOM) NC-PROG, F=1

FM 1169 WRONG TABLE POSITIONG Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 34 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1170 Z-AXIS NOT START POS.(-50.0) Cause: Effect: Remedy: Note: The Z-axis is to START NC program not MIN. position (> -50 mm) Feed stop / spindle stop Start lock

FM 1171 NC-START W/ INVALID PROG DATA Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1172 MOVE Y-AXIS TO WORK AREA Cause: Effect: Remedy: Note: Dual check safty and spindle pole detection requires Y axis in working area Feed stop / spindle stop Start lock Move Y axis manual into working area

FM 1173 Y-AXIS IN COLLISION AREA Cause: Effect: Remedy: Note: Y axis is in the malfunction area of the Q axis Feed stop / spindle stop Start lock JOG: move axis out of malfunction area (>400) AUTO: machine must be in tool change area

Version F_02 / 13.08.2008 WeK 35 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1174 Z-AXIS IN COLLISION AREA Cause: Effect: Remedy: Note: Z axis is outside the working area Feed stop / spindle stop Start lock JOG: move axis out of malfunction area (>400) AUTO: machine must be in tool change area

FM 1175 A-AXIS LOCKED IN LOAD AREA Cause: Effect: Remedy: Note: Move command to axis in loading area Feed stop / spindle stop Start lock Check NC program

FM 1176 U-AXIS LOCKED IN LOAD AREA Cause: Effect: Remedy: Note: Move command to axis in loading area Feed stop / spindle stop Start lock Check NC program

FM 1177 A-AXIS NO M11 PROGRAMMED Cause: Effect: Remedy: Note: Interpolation programmed with A even though clamping monitoring of round axis is activated with M10 Feed stop / spindle stop Start lock Program M11/M12 M12 not possible for all machines

Version F_02 / 13.08.2008 WeK 36 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1178 U-AXIS NO M11 PROGRAMMED Cause: Effect: Remedy: Note: Interpolation programmed with U/B even though clamping monitoring of round axis is activated with M10 Feed stop / spindle stop Start lock Program M11/M12 M12 not possible for all machines

FM 1180 NO T-FUNCTION PROGRAMMED Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1181 TOOL NOT FOUND Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1182 SPINDLE CONTAINS A TOOL Cause: Effect: Remedy: Note: Tool managment: To unload or load a tool into the tool magazine is only possible when the spindle is empty Feed stop / spindle stop Start lock Put all tools out of spindle into magazine

Version F_02 / 13.08.2008 WeK 37 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1183 TOOL LIFE EXPIRED Cause: Effect: Remedy: Note: If "TOOL LIFE MANGAMENT" active tool life is expired Feed stop / spindle stop Start lock Exchange tool and reset tool life in "TOOL LIFE MANGEMENT" for expiered tool

FM 1184 TOOL NUMBER OUT OF RANGE Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1185 W-POSITIONING PMC N.FINISHED Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock

FM 1186 W-AXIS NOT RELEASED "HY-B053" Cause: Effect: Remedy: Note: Axis lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for W axis

Version F_02 / 13.08.2008 WeK 38 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1187 W-AXIS NOT LOCKED "HY-B052" Cause: Effect: Remedy: Note: Axis lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for W axis

FM 1188 W-AXIS MOTOR OVERTEMP "X383" Cause: Effect: Remedy: Note: Axis has over temperature Feed stop / spindle stop Start lock

FM 1189 W-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position Feed stop / spindle stop Start lock Put A axis in homeposition Check soft cams for homeposition

FM 1190 W-AXIS LOCKED IN LOAD AREA Cause: Effect: Remedy: Note: Move command to axis in loading area Feed stop / spindle stop Start lock Check NC program

Version F_02 / 13.08.2008 WeK 39 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1191 W-AXIS NO M15 PROGRAMMED Cause: Effect: Remedy: Note: Interpolation programmed with W even though clamping monitoring of round axis is activated with M13 Feed stop / spindle stop Start lock Program M11/M12 M12 not possible for all machines

FM 1192 FIX 1 T1 N.CLAMPED "HY-B080" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 1 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 1 table 1

FM 1193 FIX 2 T1 N.CLAMPED "HY-B082" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 1 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 2 table 1

FM 1194 FIX 3 T1 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 1 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 3 table 1

Version F_02 / 13.08.2008 WeK 40 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1195 FIX 4 T1 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 1 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 4 table 1

FM 1201 PAIRCHK SETUP DOOR "S392/S396" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1202 PAIRCHK SETUP DOOR "S394/S397" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1203 PAIRCHK SETUP DOOR "S393/S90" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 41 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1204 PAIRCHK SETUP DOOR "S395/S90" Cause: Effect: Remedy: Note: Feed stop / spindle stop Start lock

FM 1208 FIX 1 T2 N.CLAMPED "HY-B090" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 2 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 1 table 2

FM 1209 FIX 2 T2 N.CLAMPED "HY-B092" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 2 table 2 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 2 table 2

FM 1210 FIX 3 T2 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 3 table 2 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 3 table 2

Version F_02 / 13.08.2008 WeK 42 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1211 FIX 4 T2 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 4 table 2 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 4 table 2

FM 1214 FIX 5 T1 N.CLAMPED Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 5 table 1 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 5 table 1

FM 1215 FIX 5 T2 N.CLAMPED Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 5 table 2 not reporting Feed stop / spindle stop Start lock Check pressure and pressure switch for clamping circuit 5 table 2

FM 1220 W2-POSITIONING PMC N.FINISHD Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock

Version F_02 / 13.08.2008 WeK 43 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1221 W2-AXIS NOT RELEASED "HY-B053" Cause: Effect: Remedy: Note: Axis lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

FM 1222 W2-AXIS NOT LOCKED "HY-B052" Cause: Effect: Remedy: Note: Axis lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

FM 1223 W2-AXIS MOTOR OVERTEMP "X385" Cause: Effect: Remedy: Note: Axis has over temperature

FM 1224 W2-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position Feed stop / spindle stop Start lock Put A axis in homeposition Check soft cams for homeposition

Version F_02 / 13.08.2008 WeK 44 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1225 W2-AXIS NO M15 PROGRAMED Cause: Effect: Remedy: Note: Interpolation programmed with W2 even though clamping monitoring of round axis is activated with M13 Feed stop / spindle stop Start lock Program M11/M12 M12 not possible for all machines

FM 1226 W2-AXIS LOCKED IN LOAD AREA Cause: Effect: Remedy: Note: Move command to axis in loading area Feed stop / spindle stop Start lock Check NC program

FM 1230 C-POSITINING PMC N.FINISHED Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock

FM 1231 C-AXIS NOT RELEASED "HY-B051" Cause: Effect: Remedy: Note: Axis lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

Version F_02 / 13.08.2008 WeK 45 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1232 C-AXIS NOT LOCKED "HY-B050" Cause: Effect: Remedy: Note: Axis lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

FM 1233 C-AXIS MOTOR OVERTEMP "X382" Cause: Effect: Remedy: Note: Axis has over temperature

FM 1234 C-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position Feed stop / spindle stop Start lock Put A axis in homeposition Check soft cams for homeposition

FM 1235 C-AXIS LOCKED IN LOAD AREA Cause: Effect: Remedy: Note: Move command to axis in loading area Feed stop / spindle stop Start lock Check NC program

FM 1236 C-AXIS NO M15 PROGRAMMED Cause: Effect: Remedy: Note: Interpolation programmed with C/U even though clamping monitoring of round axis is activated with M10 Feed stop for all axes Program M11/M12 M12 not possible for all machines

Version F_02 / 13.08.2008 WeK 46 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1238 C2-POSITIONING PMC N.FINISHD Cause: Effect: Remedy: Note: PMC positioning of axis could not be finished Feed stop / spindle stop Start lock

FM 1239 C2-AXIS NOT RELEASED "HY-B051" Cause: Effect: Remedy: Note: Axis lock is not released Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

FM 1240 C2-AXIS NOT LOCKED "HY-B050" Cause: Effect: Remedy: Note: Axis lock is not clamped Feed stop / spindle stop Start lock Check pressure and pressure switch for U axis

FM 1241 C2-AXIS MOTOR OVERTEMP "X384" Cause: Effect: Remedy: Note: Axis has over temperature

Version F_02 / 13.08.2008 WeK 47 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1242 C2-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position Feed stop / spindle stop Start lock Put A axis in homeposition Check soft cams for homeposition

FM 1243 C2-AXIS LOCKED IN LOAD AREA Cause: Effect: Remedy: Note: Move command to axis in loading area Feed stop / spindle stop Start lock Check NC program

FM 1244 C2-AXIS NO M15 PROGRAMMED Cause: Effect: Remedy: Note: Interpolation programmed with C2 even though clamping monitoring of round axis is activated with M10 Feed stop / spindle stop Start lock Program M11/M12 M12 not possible for all machines

FM 1250 SPINDEL 1 NOT ORIENTATED Cause: Effect: Remedy: Note: Spindle 1: signal for spindle set up +/- monitoring limits missing Feed stop / spindle stop Start lock Check spindle control Spindle may be blocked or moving with difficulty

Version F_02 / 13.08.2008 WeK 48 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1251 SPINDEL 2 NOT ORIENTATED Cause: Effect: Remedy: Note: Spindle 2: signal for spindle set up +/- monitoring limits missing Feed stop / spindle stop Start lock Check spindle control Spindle may be blocked or moving with difficulty

FM 1252 SPINDEL 3 NOT ORIENTATED Cause: Effect: Remedy: Note: Spindle 3: signal for spindle set up +/- monitoring limits missing Feed stop / spindle stop Start lock Check spindle control Spindle may be blocked or moving with difficulty

FM 1253 SPINDEL 4 NOT ORIENTATED Cause: Effect: Remedy: Note: Spindle 4: signal for spindle set up +/- monitoring limits missing Feed stop / spindle stop Start lock Check spindle control Spindle may be blocked or moving with difficulty

FM 1260 BLUM LASER NOT OK Cause: Effect: Remedy: Note:

FM 1261 TOOL 1 BROKEN Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 49 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1262 TOOL 2 BROKEN Cause: Effect: Remedy: Note:

FM 1263 TOOL 3 BROKEN Cause: Effect: Remedy: Note:

FM 1264 TOOL 4 BROKEN Cause: Effect: Remedy: Note:

FM 1265 LEUZE LASER NOT OK Cause: Effect: Remedy: Note:

FM 1266 LEUZE LASER DIRTY Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 50 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1280 ARTIS CHANNEL 1 NOT READY Cause: Effect: Remedy: Note:

FM 1281 ARTIS CHANNEL 2 NOT READY Cause: Effect: Remedy: Note:

FM 1282 ARTIS CHANNEL 3 NOT READY Cause: Effect: Remedy: Note:

FM 1283 ARTIS CHANNEL 4 NOT READY Cause: Effect: Remedy: Note:

FM 1284 ARTIS PROGAM NUMBER WRONG Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 51 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1285 ARTIS PROGR.TRANSFORM.WRONG Cause: Effect: Remedy: Note:

FM 1290 FAULT MARPOSS 1 Cause: Effect: Remedy: Note:

FM 1291 BATTERY ALARM MARPOSS 1 Cause: Effect: Remedy: Note:

FM 1292 FAULT MARPOSS 2 Cause: Effect: Remedy: Note:

FM 1293 BATTERY ALARM MARPOSS 2 Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 52 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1300 BALLUFF SYSTEM NOT READY Cause: Effect: Remedy: Note:

FM 1301 BALLUFF CODETAG 1 NOT PRESENT Cause: Effect: Remedy: Note:

FM 1302 BALLUFF CODETAG 2 NOT PRESENT Cause: Effect: Remedy: Note:

FM 1303 TOOL NOT FOR MACHINE S/N Cause: Effect: Remedy: Note:

FM 1304 TOOL AND POCKET ID MISSMATCH Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 53 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1305 TOOL ID 1 AND ID 2 MISSMATCH Cause: Effect: Remedy: Note:

FM 1306 TOOL LENGTH DATA MISSMATCH Cause: Effect: Remedy: Note:

FM 1307 TOOL DATA OUT OF RANGE Cause: Effect: Remedy: Note:

FM 1310 MM-INCH - CHECK RESOLUTION Cause: Effect: Remedy: Note: Milimter or inch was changed check between SW option and Fanuc option does not match

FM 1311 SET SPINDLE DIRECTION Cause: Effect: Remedy: Note: The Spindle direction is not set Feed stop / spindle stop Start lock Set spindle direction as neccessary Turn OFF and ON the machine

Version F_02 / 13.08.2008 WeK 54 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
FM 1312 CHECK SPINDLE DIRECTION Cause: Effect: Remedy: Note: The Spindle direction has to be checked Feed stop / spindle stop Start lock Check changed spindle direction

FM 1313 PLEASE TURN OFF-ON MACHINE Cause: Effect: Remedy: Note: SW options were changed

FM 1314 MOVE SEL AXIS MIN 1 ROTATION Cause: Effect: Remedy: Note: During reference move selected axis minimum 1 motor rotation

BM 2001 MAGZN BALANCE TRIPPED Cause: Effect: Remedy: Note:

BM 2002 C/LUBE OIL PREWARN "ZS-B120" Cause: Effect: Remedy: Note: Oil level prewarning for lubrication unit None Fill lubricant unit oil to MAX

Version F_02 / 13.08.2008 WeK 55 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2003 C/LUBE MIN LEVEL "ZS-B121" Cause: Effect: Remedy: Note: Oil level minimum for lubrication unit Next Start lock Fill lubricant unit oil to MAX

BM 2004 SP/LUBE PREWRN LEVEL Cause: Effect: Remedy: Note: Oil level prewarning for spindle lubrication unit None Fill spindle lubricant unit oil to MAX

BM 2005 SP/LUBE MIN LEVEL Cause: Effect: Remedy: Note: Oil level minimum for spindle lubrication unit Next Start lock Fill spindle lubricant unit oil to MAX

BM 2006 HYDRAULIC OIL PREWRN Cause: Effect: Remedy: Note: Hydraulics: oil minimum level Next Start lock Fill oil until oil to MAX

BM 2007 HYDR RETRN FILTR DIRTY Cause: Effect: Remedy: Note: Hydraulics: return filter dirty Next Start lock Replace return filter

Version F_02 / 13.08.2008 WeK 56 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2008 HYDR FILTER DIRTY "HY-B143" Cause: Effect: Remedy: Note: Hydraulics: filter dirty Next Start lock Replace filter

BM 2010 FILTR AIR PURGE DIRTY Cause: Effect: Remedy: Note: Air purge filter for measuring system dirty

BM 2011 EXHAUSTSYSTEM DIRTY Cause: Effect: Remedy: Note: Filter for exhuast system dirty

BM 2012 MTR OVLD EXHAUSTSYSTEM "Q18" Cause: Effect: Remedy: Note: Over-current trigger for air exhaust system has engaged

BM 2016 TL SP 1 CLAMPED TO SHORT Cause: Effect: Remedy: Note: Tool clamping device 1: clamping error, too short Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 57 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2017 TL SP 1 CLAMPED TO LONG Cause: Effect: Remedy: Note: Tool clamping device 1: clamping error, too long Feed / spindle stop Tool / check tool clamping device signals / clamping jaw See operating instructions and SW diagnostics

BM 2018 TL SP 1 NOT SEATED CORRECT Cause: Effect: Remedy: Note: Tool clamping device 1: plane surface error Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

BM 2020 TL SP 2 CLAMPED TO SHORT Cause: Effect: Remedy: Note: Tool clamping device 2: clamping error, too short Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

BM 2021 TL SP 2 CLAMPED TO LONG Cause: Effect: Remedy: Note: Tool clamping device 2: clamping error, too long Feed / spindle stop Tool / check tool clamping device signals / clamping jaw See operating instructions and SW diagnostics

BM 2022 TL SP 2 NOT SEATED CORRECT Cause: Effect: Remedy: Note: Tool clamping device 2: error, no plane surface Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 58 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2024 MAGZIN NOT LOCKED "PN-S011/013" Cause: Effect: Remedy: Note: Limit switch tool slot 1/2 is not locked Tool change will not be performed any more Check proximity switch See operating instructions and SW diagnostics

BM 2025 NO ENABLE TURN MAGAZINE Cause: Effect: Remedy: Note:

BM 2028 COOLNT TEMP NOT REACHED Cause: Effect: Remedy: Note:

BM 2029 FAULT COOLNT HEATR "S260" Cause: Effect: Remedy: Note:

BM 2030 MIN LEVEL BKW COOLER "S151" Cause: Effect: Remedy: Note: MIN coolant for BKW cooler Start lock Fill with coolant to MAX

Version F_02 / 13.08.2008 WeK 59 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2031 OVRLOAD COOLANT "S271" Cause: Effect: Remedy: Note: Over-current trigger for coolant system has engaged Feed stop / spindle stop Start lock Check currents Switch the trigger into the circuit Compact system: all triggers for coolant. Systems with additional container (ASI): auxiliary drives except for coolant pumps (external/internal cooling)

BM 2032 OVRLOAD CHIPCNV "S272" Cause: Effect: Remedy: Note: Over-current trigger for chipconveyor has engaged Feed stop / spindle stop Start lock Check currents Switch the trigger into the circuit

BM 2033 DUBBEL FILTER DIRTY "S290" Cause: Effect: Remedy: Note: Coolant: double filter dirty Start lock Switch / replace filter

BM 2034 PAPER BAND FINISHED "S293" Cause: Effect: Remedy: Note: Coolant: fleece end Start lock Replace paper roll, check switch on the roll

BM 2035 RUN TIME PAPER BAND EXCEEDED Cause: Effect: Remedy: Note: Coolant: fleece drive runtime monitoring Start lock Check switch on belt drive, belt drive Intended to prevent unnecessary use of paper

Version F_02 / 13.08.2008 WeK 60 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2036 PRES SW TURBOFILTR "S291" Cause: Effect: Remedy: Note: Coolant: error in turbo filter system pressure switch Start lock Pressure switch reporting too long (> 15 sec.) during cleaning Clean turbo filter

BM 2037 PRES SW.TURBOFILTR ACCUMULATED Cause: Effect: Remedy: Note:

BM 2038 COOLANT MIN PREWRN "S273" Cause: Effect: Remedy: Note: Coolant: floater switch prewarning for belt filter system minimum Start lock Check floater switch, refill with water The message can be eliminated by the next end of program with the error delete key.

BM 2039 MUD WATR PREWARN TURBO "S273" Cause: Effect: Remedy: Note: Coolant: MIN dirty water floater switch prewarning for turbo filter has engaged Start lock Check MIN pre-warning floater switch, refill with water

BM 2040 COOLANT MIN LEVEL "S282" Cause: Effect: Remedy: Note: Coolant: floater switch minimum for belt filter system

Version F_02 / 13.08.2008 WeK 61 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2041 MUDY WATR MAX TURBO "S291" Cause: Effect: Remedy: Note:

BM 2042 COOLANT MAX LEVEL "S280" Cause: Effect: Remedy: Note: In the swarf conveyor is to much water

BM 2043 TL SP 3 CLAMPED TO SHORT Cause: Effect: Remedy: Note: Tool clamping device 3: clamping error, too short Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

BM 2044 TL SP 3 CLAMPED TO LONG Cause: Effect: Remedy: Note: Tool clamping device 3: clamping error, too long Feed / spindle stop Tool / check tool clamping device signals / clamping jaw See operating instructions and SW diagnostics

BM 2045 TL SP 3 NOT SEATED CORRECT Cause: Effect: Remedy: Note: Tool clamping device 3: plane surface error Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

Version F_02 / 13.08.2008 WeK 62 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2046 TL SP 4 CLAMPED TO SHORT Cause: Effect: Remedy: Note: Tool clamping device 4: clamping error, too short Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

BM 2047 TL SP 4 CLAMPED TO LONG Cause: Effect: Remedy: Note: Tool clamping device 4: clamping error, too long Feed / spindle stop Tool / check tool clamping device signals / clamping jaw See operating instructions and SW diagnostics

BM 2048 TL SP 4 NOT SEATED CORRECT Cause: Effect: Remedy: Note: Tool clamping device 4: error, no plane surface Feed / spindle stop Check tool / check tool clamping device signals See operating instructions and SW diagnostics

BM 2050 LOAD DOOR N.UNLOCKED "MA-S401" Cause: Effect: Remedy: Note: Interlock from loading door is not unlocked None Interlock magnet feedback, loading door missing

BM 2052 LOAD DOOR NOT OPENED "E363" Cause: Effect: Remedy: Note: Landert drive for loading door has error upon opening None Check Landert/loading door No loading enable with robot operation (loading from above)

Version F_02 / 13.08.2008 WeK 63 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2053 LOAD DOOR N.LOCKED "MA-S401" Cause: Effect: Remedy: Note: Interlock from loading door is not locked Machine not ready Check covering interlock

BM 2060 TOOL BROKEN ARTIS CHANNEL 1 Cause: Effect: Remedy: Note:

BM 2061 TOOL MISSING ARTIS CHANNEL 1 Cause: Effect: Remedy: Note:

BM 2062 TOOL WORN ARTIS CHANNEL 1 Cause: Effect: Remedy: Note:

BM 2063 TOOL BROKEN ARTIS CHANNEL 2 Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 64 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2064 TOOL MISSING ARTIS CHANNEL 2 Cause: Effect: Remedy: Note:

BM 2065 TOOL WORN ARTIS CHANNEL 2 Cause: Effect: Remedy: Note:

BM 2066 TOOL BROKEN ARTIS CHANNEL 3 Cause: Effect: Remedy: Note:

BM 2067 TOOL MISSING ARTIS CHANNEL 3 Cause: Effect: Remedy: Note:

BM 2068 TOOL WORN ARTIS CHANNEL 3 Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 65 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2069 TOOL BROKEN ARTIS CHANNEL 4 Cause: Effect: Remedy: Note:

BM 2070 TOOL MISSING ARTIS CHANNEL 4 Cause: Effect: Remedy: Note:

BM 2071 TOOL WORN ARTIS CHANNEL 4 Cause: Effect: Remedy: Note:

BM 2072 ARTIS REWORK ACTIVE Cause: Effect: Remedy: Note:

BM 2074 A-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position

Version F_02 / 13.08.2008 WeK 66 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2075 U-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position

BM 2076 C-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position

BM 2077 W-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position

BM 2078 C2-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position

BM 2079 W2-AXIS NOT IN HOME POSITION Cause: Effect: Remedy: Note: Axis is not in swiveling position

Version F_02 / 13.08.2008 WeK 67 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2108 EMERGENCY STOP "P1-S400" Cause: Effect: Remedy: Note: EMERGENCY STOP button pressed Machine cannot be turned on Free the EMERGENCY STOP button Check the EMERGENCY STOP circuit

BM 2111 SETUP DOOR NOT CLOSED "MA-7S1-4" Cause: Effect: Remedy: Note:

BM 2114 TLCHANGR NOT IN HOME POSITION Cause: Effect: Remedy: Note: Tool changer not in basic setting Feed stop, no tool change possible Move tool change to basic setting with basic setting key See operating instructions

BM 2115 FUSE TRIPPED Cause: Effect: Remedy: Note:

BM 2120 SINGLE STEP MODE ACTIVE Cause: Effect: Remedy: Note: Key "Single movement" is selected Only JOG or INCJ Mode is possible Additional movements are allowed Turn off "Singlemovement" Check key switch if working properly By authorized personnel only (JOG/REF: SK: user consent if everything is OK)

Version F_02 / 13.08.2008 WeK 68 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2121 ELEC.CABINT TEMP NOT OK "A11.6" Cause: Effect: Remedy: Note: The electrical cabinet temperature is to high None Check cooler in electrical cabinet Check adjusted temperature

BM 2122 MACHINING W/O COOLANT SYSTEM Cause: Effect: Remedy: Note: Option Bit for "No Coolant" is selected No coolant available Select with option bit the "Coolant System" See Keeprelais list or machine documentation

BM 2123 Q-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: Q axis absolute encoder not adjusted The axis can only be moved when the axis selection key is pressed to avoid collisions Calibrate the Q axis measuring system By authorized personnel only (JOG/REF: SK: user consent if everything is OK)

BM 2124 X-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: X axis absolute encoder not adjusted The axis can only be moved when the axis selection key is pressed to avoid collisions Calibrate the X axis measuring system By authorized personnel only

BM 2125 Y-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: Y axis absolute encoder not adjusted The axis can only be moved when the axis selection key is pressed to avoid collisions Calibrate the Y axis measuring system By authorized personnel only

Version F_02 / 13.08.2008 WeK 69 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2126 Z-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: Z axis absolute encoder not adjusted The axis can only be moved when the axis selection key is pressed to avoid collisions Calibrate the Z axis measuring system By authorized personnel only

BM 2127 A-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: A axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the A axis measurement system By authorized personnel only

BM 2128 U-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: U axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the U axis measurement system By authorized personnel only

BM 2129 MAGAZINE NOT REFERENCED Cause: Effect: Remedy: Note: MAG axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the MAG axis measurement system By authorized personnel only

BM 2130 C-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: C axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the C axis measurement system By authorized personnel only

Version F_02 / 13.08.2008 WeK 70 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2131 W-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: W axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the W axis measurement system By authorized personnel only

BM 2132 CABINT DOOR NOT CLOSED "KE14" Cause: Effect: Remedy: Note:

BM 2133 C2-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: C2 axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the C2 axis measurement system By authorized personnel only

BM 2134 W2-AXIS NOT REFERENCED Cause: Effect: Remedy: Note: W2 axis absolute encoder not adjusted The axis can only be moved with the axis selection key pressed to avoid collisions Calibrate the W2 axis measurement system By authorized personnel only

BM 2138 MAGAZINE LOAD DOOR NOT LOCKED Cause: Effect: Remedy: Note: Magazine loading door interlock switch closed not reporting Magazine cannot be moved Close magazine loading door, check lock switch of magazine loading door

Version F_02 / 13.08.2008 WeK 71 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2139 LOADG.UNIT AT TL MAGAZN ACTIVE Cause: Effect: Remedy: Note: Loading console for tool magazine turned on Machine control panel is locked Turn off tool magazine control panel Check tool magazine control panel switch

BM 2140 LOAD/UNLOAD ONLY IN JOG MODE Cause: Effect: Remedy: Note: Tool management: loading/unloading of tools only possible in JOG and RESET state No loading/unloading of tools possible JOG - RESET- new selection

BM 2141 LOAD/UNLOAG MAGAZINE ACTIVE Cause: Effect: Remedy: Note: Loading and unloading activated with key switch Control panel locked Complete load/unload tool function

BM 2148 NO PROGRAM MODE SELECTED Cause: Effect: Remedy: Note: No program operating mode selected (F/C) Start lock Select operating program (F/C) in JOG, MSST key Please note: in F mode, the selected program (SIEMENS selection) is started, not the program from the SW program list.

BM 2149 NO PROGRAM ENTRY Cause: Effect: Remedy: Note: SW menu: no program entry Start lock Select program in SW menu See operating instructions

Version F_02 / 13.08.2008 WeK 72 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2151 LOAD DOOR FAULT 1 (LANDERT) Cause: Effect: Remedy: Note: Landert drive for loading door reporting malfunction 1 (general malfunctions) Feed and spindle stop / start lock Check Landert/loading door

BM 2152 LOAD DOOR FAULT 2 (LANDERT) Cause: Effect: Remedy: Note: Check loading door for ease of motion Landert drive for loading door has malfunction: obstruction

BM 2155 SAFTY STRIP LOAD DOOR Cause: Effect: Remedy: Note:

BM 2156 LOAD DOOR NOT CLOSED Cause: Effect: Remedy: Note: Landert drive for loading door has error upon closing Start lock Check Landert/loading door

BM 2158 Q-AXIS NOT IN DEFINED POS. Cause: Effect: Remedy: Note: Table setting not correct No additional functions possible Check position of Q axis 0/180 degrees, check soft cam, cycle swivel carrier system, NCK reset if required By authorized personnel only

Version F_02 / 13.08.2008 WeK 73 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2164 FIXTURE T1 NOT IN LOAD/UNL.POS Cause: Effect: Remedy: Note: Table A is not in the unloading or loading position to open the clamping device Clamping mechanism for table A is not releasing Move table A to correct position, SW menu: setup axes basic setting value Basic setting / cycle key

BM 2165 FIXTURE T1 NOT CLAMPED Cause: Effect: Remedy: Note: Fixture table 1 not clamped No other functions are possible Clamp Fixture

BM 2166 FIX 1 T1 N.CLAMPED "HY-B080" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 1 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 1 table 1

BM 2167 FIX 2 T1 N.CLAMPED "HY-B082" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 2 table 1 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 2 table 1

BM 2168 FIX 3 T1 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 3 table 1 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 3 table 1

Version F_02 / 13.08.2008 WeK 74 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2169 FIX 4 T1 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 4 table 1 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 4 table 1

BM 2171 TOOL DETAIL - TOOL BLOCKED Cause: Effect: Remedy: Note:

BM 2172 TOOL DETAIL - PREWARN LIMIT Cause: Effect: Remedy: Note:

BM 2173 TOOL DETAIL Cause: Effect: Remedy: Note:

BM 2174 TOOL DETAIL Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 75 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2175 TOOL DETAIL Cause: Effect: Remedy: Note:

BM 2180 FIXTURE T2 NOT IN LOAD/UNL.POS Cause: Effect: Remedy: Note: Table U is not in the unloading or loading position to open the clamping device Clamping mechanism for table U is not releasing Move table U to correct position, SW menu: setup axes basic setting value Basic setting / cycle key

BM 2181 FIXTURE T2 NOT CLAMPED Cause: Effect: Remedy: Note: Fixture table 2 not clamped No other functions are possible Clamp Fixture

BM 2182 FIX 1 T2 N.CLAMPED "HY-B090" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 1 table 2 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 1 table 2

BM 2183 FIX 2 T2 N.CLAMPED "HY-B092" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 2 table 2 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 2 table 2

Version F_02 / 13.08.2008 WeK 76 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2184 FIX 3 T2 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 3 table 2 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 3 table 2

BM 2185 FIX 4 T2 N.CLAMPED "HY-B" Cause: Effect: Remedy: Note: Pressure switch for clamping circuit 4 table 2 not reporting Clamped message not reached Check pressure and pressure switch for clamping circuit 4 table 2

BM 2186 FAULT AIR CONTROL 1 TABLE 1 Cause: Effect: Remedy: Note:

BM 2187 FAULT AIR CONTROL 1 TABLE 2 Cause: Effect: Remedy: Note:

BM 2188 FAULT AIR CONTROL 2 TABLE 1 Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 77 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2189 FAULT AIR CONTROL 2 TABLE 2 Cause: Effect: Remedy: Note:

BM 2190 FIX 5 T1 N.CLAMPED Cause: Effect: Remedy: Note:

BM 2191 FIX 5 T2 N.CLAMPED Cause: Effect: Remedy: Note:

BM 2196 CONFIRM R/TABLE MISSING Cause: Effect: Remedy: Note: No acknowledgement of fitting Table not dividing, BSTQ lamp remains dark Confirm acknowledgement of fitting, check key Look for any additional messages, SPVO clamped, etc.

BM 2197 CONFIRM - NO TOOL IN MAGAZINE Cause: Effect: Remedy: Note:

Version F_02 / 13.08.2008 WeK 78 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2200 MAINTENANCE REQUIRED Cause: Effect: Remedy: Note:

BM 2201 MAINTENANCE OVERTIME Cause: Effect: Remedy: Note:

BM 2212 SPI 1 TOLERANCE BAND "SPALA" Cause: Effect: Remedy: Note:

BM 2213 SPI 1 SPEED NOT ZERO "SSTA" Cause: Effect: Remedy: Note: Spindle 1: standstill signal +/- monitoring limits missing Feed stop Check spindle control See Fanuc Spindle Manual

BM 2214 SPI 1 NO SPEED DETECT "SDTA" Cause: Effect: Remedy: Note: Spindle 1: No speed detected Feed stop Check spindle control See Fanuc Spindle Manual

Version F_02 / 13.08.2008 WeK 79 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2215 SPI 1 SPEED NOT REACHED "SARA" Cause: Effect: Remedy: Note: Spindle 1: Commanded spindle speed not reached Feed stop Check spindle control See Fanuc Spindle Manual

BM 2216 SPI 1 NOT ORIENTED "ORARA" Cause: Effect: Remedy: Note: Spindle 1: Spindle not orientated (M19) Feed stop Check spindle control See Fanuc Spindle Manual

BM 2220 SPI 2 TOLERANCE BAND "SPALB" Cause: Effect: Remedy: Note:

BM 2221 SPI 2 SPEED NOT ZERO "SSTB" Cause: Effect: Remedy: Note: Spindle 2: standstill signal +/- monitoring limits missing Feed stop Check spindle control See Fanuc Spindle Manual

BM 2222 SPI 2 NO SPEED DETECT "SDTB" Cause: Effect: Remedy: Note: Spindle 2: No speed detected Feed stop Check spindle control See Fanuc Spindle Manual

Version F_02 / 13.08.2008 WeK 80 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2223 SPI 2 SPEED NOT REACHED "SARB" Cause: Effect: Remedy: Note: Spindle 2: Commanded spindle speed not reached Feed stop Check spindle control See Fanuc Spindle Manual

BM 2224 SPI 2 NOT ORIENTED "ORARB" Cause: Effect: Remedy: Note: Spindle 2: Spindle not orientated (M19) Feed stop Check spindle control See Fanuc Spindle Manual

BM 2227 CONFIRMATION MODE ACTIVE Cause: Effect: Remedy: Note:

BM 2228 FEED OVERRIDE TO 0% Cause: Effect: Remedy: Note: Feed correction switch is set to 0% Axes not moving Set feed correction switch to greater than 0% Check switch Message pending. After Q axis move to single movement operating mode

BM 2229 TL-CLAMP MONITOR SWITCHED OFF Cause: Effect: Remedy: Note: Key switch "Bridge tool clamping device" turned on Tool clamping device monitoring is turned off; spindle limited to 150 rpm Turn off "Bridge tool clamping device" Check "Bridge tool clamping device" switch

Version F_02 / 13.08.2008 WeK 81 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2230 SPINDLE SPEED LIMIT TO 150 RPM Cause: Effect: Remedy: Note: Tool clamping device reporting not completely tightened (without tool); the spindle speed is limited to 150/rpm Spindle can only turn at max.150 rpm Tool in spindle Check tool clamping device See operating instructions

BM 2231 M39 / FEED LIMIT ACTIVE Cause: Effect: Remedy: Note:

BM 2232 ROB:FUSE TRIPPED Cause: Effect: Remedy: Note:

BM 2233 ROB: Cause: Effect: Remedy: Note:

BM 2234 ROB:LOAD DOOR N.OPN "S073/072" Cause: Effect: Remedy: Note: Robot: Additional switch for Load door is not open No enalbe for robot Open load door for robot Check additional load door switch

Version F_02 / 13.08.2008 WeK 82 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2235 ROB: Cause: Effect: Remedy: Note:

BM 2236 ROBOT SAFTY GUARD NOT CLOSED Cause: Effect: Remedy: Note: Robot: Safty guard around robot is not closed SW- Machine will not work in load area Close safty guard Check safty guard switch

BM 2237 ROBOT NOT READY Cause: Effect: Remedy: Note: Robot: Robot is not ready for operation Robot signals will not be transmitted See robot authorised personal

BM 2238 ROB: Cause: Effect: Remedy: Note:

BM 2239 ROBOT ON: CHECK PART STATUS Cause: Effect: Remedy: Note: Robot: Robot is new selected No enalbe for robot Check part status in SW-Menue

Version F_02 / 13.08.2008 WeK 83 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2240 ROB: EMPTY OUT MACHINE ACTIVE Cause: Effect: Remedy: Note: Robot: Empty out machine is selected Machine will not proceed with production Turn off selection "Empty Out Machine"

BM 2241 ROB: P/CHECK L-DOOR OPEN/CLOSE Cause: Effect: Remedy: Note: Robot: Both limit switches of load door open/close were engaged No enalbe for robot Check limit switches for load door open / close

BM 2242 SPI 3 TOLERANCE BAND "SPALC" Cause: Effect: Remedy: Note:

BM 2243 SPI 3 SPEED NOT ZERO "SSTC" Cause: Effect: Remedy: Note: Spindle 3: standstill signal +/- monitoring limits missing Feed stop Check spindle control See Fanuc Spindle Manual

BM 2244 SPI 3 NO SPEED DETECT "SDTC" Cause: Effect: Remedy: Note: Spindle 3: No speed detected Feed stop Check spindle control See Fanuc Spindle Manual

Version F_02 / 13.08.2008 WeK 84 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2245 SPI 3 SPEED NOT REACHED "SARC" Cause: Effect: Remedy: Note: Spindle 3: Commanded spindle speed not reached Feed stop Check spindle control See Fanuc Spindle Manual

BM 2246 SPI 3 NOT ORIENTED "ORARC" Cause: Effect: Remedy: Note: Spindle 3: Spindle not orientated (M19) Feed stop Check spindle control See Fanuc Spindle Manual

BM 2250 SPI 4 TOLERANCE BAND "SPALD" Cause: Effect: Remedy: Note:

BM 2251 SPI 4 SPEED NOT ZERO "SSTD" Cause: Effect: Remedy: Note: Spindle 4: standstill signal +/- monitoring limits missing Feed stop Check spindle control See Fanuc Spindle Manual

BM 2252 SPI 4 NO SPEED DETECT "SDTD" Cause: Effect: Remedy: Note: Spindle 4: No speed detected Feed stop Check spindle control See Fanuc Spindle Manual

Version F_02 / 13.08.2008 WeK 85 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

FM/BM 1xxx/2xxx
BM 2253 SPI 4 SPEED NOT REACHED "SARD" Cause: Effect: Remedy: Note: Spindle 4: Commanded spindle speed not reached Feed stop Check spindle control See Fanuc Spindle Manual

BM 2254 SPI 4 NOT ORIENTED "ORARD" Cause: Effect: Remedy: Note: Spindle 4: Spindle not orientated (M19) Feed stop Check spindle control See Fanuc Spindle Manual

Version F_02 / 13.08.2008 WeK 86 / 86 T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot

Вам также может понравиться