Вы находитесь на странице: 1из 13
AIVALDELK Engineers & Constructors ‘VALDEL ENGINEERS & CONSTRUCTORS PVT LTD. ‘MEGHDOOTH MANSION 9, CIVIL STATION HOSUR ROAD BANGALORE-560025 (INDIA) BHARUCH - JAMNAGAR PIPELINE PROJECT (RAJKOT JAMNAGAR SECTION) GUJARAT STATE PETRONET LIMITED ‘TRACTEBEL ENGINEERS & CONSTRUCTORS PVT. LTD MAYTAS NAFTOGAS BUD CONSORTIUM : VALDEL ENGINEERS & CONSTRUCTORS PVT. LTD 2 9468VE GSPL203 - 75-3510 CABLE SIZING CALCULATION-SV3 STATION @ BERAJA PASAYA DATE REVISION DFSCRIPTI VALDEL ENGINEERS & JPAGE No.2 of 6 ‘CONSTRUCTORS. REVISION STATUS SHEET [DOCUMENT No. GSPL203-75-3510 JDOCUMENT TITLE CABLE SIZING CALCULATION SVB Station (@ Beraja Pasaya) ‘DOL REV. | PAGENs. | REV] ADDL. PAGE No. m 7128) 7128) 730) 732, 134, 135, 136 138 730) “10 s|a|e/¢\e/sle/ale a2, 743, 144 45; 146. 407 18 749 TH IF REVISION REQUIRES ADDITIONAL PAGES TO BE INSERTED IN BETWEEN THE DOCUMENT, THE NUMBER OF THE PAGE AT INSERTION SHALL BE NUMBERED WITH DECIMAL (ag. INSERTION BETWEEN PAGE 10 AND 11 SHALL BE NUMBERED AS 1044, 102.) Fram {Waldeisbs68veoc\TO GLIENTICABLE SINGIREV OTGSPL209 75301452 MAYTAS NAFTOGAS BUD CONSORTIUM GSPL203-75-3510 Revo OBJECTIVE: ‘The purpose ofthis calculation is to determine the cross sections of the low voltage cable to be installed in SV3 Station @ Beraja Pasaya, ABBREVIATIONS: GEB = Gujarat Electricity Board 2) MEDB = Main Electrical Distribution board OLDB = Outdoor Lighting Distribution Board REFERENCE DOCUMENTS: @ | strtte3.0105 since LINE DIAGRAM: Sva STATION AT BERAIA PASAYA 2) 61111-C-14-0205 — PLOT PLAN SV3 STATION @ BERAJA PASAYA 3) GSPL203-753503 ELECTRICAL LOAD DATASV3 STATION @ BERAJA PASAYA 4) 61111-€-15-0804 CABLE TRENCH LAYOUT CONTROL ROOM BUILDING SV3 STATION @ BERAJA PASAYA 5) 61109/16/11/E/51/0006 -ELECTRICAL DESIGN BASIS. 4 INPUTS / ASSUMPTIONS: | CABLE DETAILS 1. Voltage Grade 1100V 2.Type ot Cable 1.1 kV PVC insulated, Extruded PVC inner sheath & PVC outer sheath, steelstripiwire armoured, outer sheath shall have FRLS characteristics 3, Power Cable ‘Stranded Annealed Copper Conductor up to 16 sq.mm Stranded Aluminium Conducta from 25 sq.mm and above 4. Permisible Vottage drop : 5% 5. The main incoming cable from GEB & DG set to MEDB shall be buried directly underground e All other cables are route in concrete trenches via cable trays 6. The Current ratings, rating factors, resistance & reactance values are taken from the cable manufacturer's catalogue (Refer Attachment) Ml Calculation of Combined Derating factor For calculating Derating factor, ground temperature is assumed as 35 degree celsius and thermal resistivity of soil is taken as 200 deg c.cm/w ‘A. Rating factor for variation in ground temperature 0.94 8 - Rating factor for variation in thermal resistivity of soil og C- Rating factor for variation in depth of faying 0.99 (for 800mm) D- Rating factor for laying cables in horizontal formation 0.79 (2 cables in groups touching) [DOC.NO.: GSPL203-75-35 10 VALDEL ENGINEERS |PROJECT: BHARUCH JAMNAGAR PIPELINE PROJECT & CONSTRUCTORS frifte : CABLE SIZING CALCULATION- 8V3 STATION @ BERAJA PASAYA Cable sizing Calculation 8V3 Station @ Beraja Pasaya Page 3 of 6

Вам также может понравиться