Вы находитесь на странице: 1из 6
2IVALDELEK Engineers & Constructors \VALDEL ENGINEERS & CONSTRUCTORS PVT LTD MEGHDOOTH MANSION 9, CIVIL STATION HOSUR ROAD BANGALORE-S60025 (INDIA) VALDEL_D.C COPY oare: (Ao 7407} BHARUCH - JAMNAGAR PIPELINE PROJECT (RAJKOT JAMNAGAR SECTION) GUJARAT STATE PETRONET LIMITED ‘TRACTEBEL ENGINEERS & CONSTRUCTORS PVT. LTD MAYTAS NAFTOGAS BUD CONSORTIUM : VALDEL ENGINEERS & CONSTRUCTORS PVT. LTD 9468VE, GSPL203 - 75-3520 EARTHING & LIGHTNING PROTECTION CALCULATION- RECEIVING STATION @ RELIANCE ee a ie paral I fimtena so peer ameanaeis | DATE TEVISION DESCRIPTION PAGE No 20f6 VALDEL ENGINEERS & (GE No.2 of CONSTRUCTORS. REVISION STATUS SHEET [CONTRACT No. 66 lev. 0 DATE: 17-07 07 [DOCUMENT No. GSPL203-75.3520 [SION DOCUMENT TITLE EARTHING AND LIGHTNING PROTECTION CALCULATION [sHT__1 OF Receiving Station @ Reliance ‘ADDL REV. | PAGE Wo, ] REV. | ADDL | REV. [PAGE No, PAGE No. $02 103 104 105) 106 134) 735) 736, 138 140 ar 168 te 77 46, a7, 96 “a6, 9 48 100) 150 INOTE: WF REVISION REQUIRES ADDITIONAL PAGES TO BE INSERTED IN BETWEEN THE DOGUMENT, THE NUMBER OF THE PAGE AT INSERTION SHALL BE NUMBERED WITH DECIMAL (eg. INSERTION BETWEEN PAGE 10.ANO 11 SHALL BE NUMBERED AS 10.1, 102...) Fisas Taide Ou 46d woe DetvarabieslDoninecsiearting Rov DIGSPLZ00 7S G520 6 MAYTAS NAFTOGAS BUD CONSORTIUM GSPL203-75-3520 Revo PURPOSE ‘This document provides the resistance calculation for the earthing grid. Earthing system is designed to limit the earth grid resistance to 1 ohm in accordance with the tender documents, BASIS FOR EARTHING SYSTEM DESIGN Soil resistivity varies with depth. The average value taken depth wise is 10 ohm metre. For Calculation a soll resistivity value of 15 ohm metre is considered, REFERENCE DOCUMENTS 4. 18:3043- Code of Practice for Earthing 2'18:2308- Code of Practice forthe Protection of Buildings & Alied Structures against Lighting 3. Eloctical Design Basis - 61 109/16'11/E/61/0006 44 PTS-Eloctical Package - 61109/16/2 76/21/0451 5. GTS- Electrical Grounding system - £102/2505, e@ 6. Overall earthing layout- Receiving station @ Reliance - 61111-€-15-0408 7 Earthing layout - Control room Dullng - Receiving station @ Reliance ~61111-£-16-0908 CALCULATION CONDUCTOR SELECTION ‘The mein earth grid shall be formed with 0 X 6 mm G. flat buried al the depth of 700mm over the area CALCULATION OF RESISTANCE CALCULATION OF RESISTANCE FOR PIPE ELECTRODE As per IS-3043, ‘The resistance of a pipe electrodes is given by RL tor xh 4%! hms ——) Zeal Where 1-length of pipe in em r ) d= diameter of pipe in cm _p- fesistivty ofthe soil in ohm-metre p15 ohm metre d= 6.5 em dia as per design basis 1-300 om as per design basis Substituting these values in the equation 1 10015 | 4*300 =x nol 2* 7300 6.5 nm R1=4.15 Ohms 10 electrodes are envisaged and they are connected in parallel Total resistance of the electrodes (R1) = 0.415 ohms. [CONTRACT NO: o480VE VALDEL ENGINEERS | PROJECT: BHARUCH JAMNAGAR PIPELINE PROJECT & CONSTRUCTORS [TITLE : EARTHING & LIGHTNING CALCULATION Earthing lightning calculation Recelving Station @ Reliance

Вам также может понравиться