ENGINEERING DESIGN CALCULATION - DENNIS KIRK SINGLE STAGE CENTRIFUGAL PUMP CALCULATION (Clean Water Use) Static Suction

Lift = Ls Pump Suction Diam = Ds Static Discharge Head = Ld Pump Discharge Diam = Dd Total Static Head Ltot = Ls + Ld Friction Head = Hfs and Hfd Inlet and Discharge Nozzle Losses = Hi and Ho Pou t Velocity Head = V2/2g [often included in pump curves] Pump Suction and Discharge Nozzle Elevations = Lns and Lnd Suction Pressure Head = Ps [if open tank = 0] Discharge Pressure Head = Pd [if open tank = 0]

denniskb@ozemail.com.au Version 1.001 SYSTEM CURVE


250.00

Pd

Nov-97

Ho
200.00

Ld
METRES HEAD

Vd

H f d L nd

150.00

C L

100.00

Lns Vs Ls Ps H i
Total Dynamic Suction Lift Total Dynamic Discharge Head Total Dynamic Head Hs = Ls - Ps + Hfs + Hi - Vs2/2g Hd = Ld + Pd + Hfd + Ho + Vd2/2g Htot = Hd + Hs Pout = Pd + Ld + Hfd + Ho - Lnd = Hd - Vd2/2g - Lnd

Lt t o
50.00

H fs
Pn i
Pin = Ps - Ls - Hfs - Hi + Lns = - Hs - Vs 2/2g + Lns
0.00 0 100 200 L/sec 300 400 500

2 Closed Tank: NPSHa(abs) = Ps + Patm - Ls - Hfs - Hi + Vs /2g - Pvap [where Pvap = Vapour Pressure(abs)] 2 Open Tank: or = Pamb - Ls - Hfs - Hi + Vs /2g - Pvap [NPSHa should exceed NPSHr by at least 0.5 m]

Dynamic Suction Lift (req'd) Hs(r) = Ls - Ps + Hfs + Hi Dynamic Discharge Head (req'd) Hd(r) = Ld + Pd + Hfd + Ho Dynamic Head (req'd) Htot(r) = Hd(r) + Hs(r) NPSHa(r) = NPSHa - Vs2/2g NPSHa(req'd) Provide this to pump vendor and use on pump curves where velocity head is included in vendors pump curves. PUMP SELECTION (Nominal) kPa(abs) kPa(abs) m/sec kPa(g) kPa kPa m/sec kPa(g) kPa kPa kPa kPa kPa(g) kPa(g) Pump Speed Impeller Diam Pump Head Hydraulic Power Pump Efficiency Motor Power Specific Speed 1483 0.449 61.95 117.12 83.8% 139.76 1069 2 1.666 m m rpm m m kW kW

Q SG Tfluid Pvap Ps Ls Hi Hfs Ds Lns Pd Ld Ho Hfd Dd Lnd

SYSTEM PROPERTIES 215 l/sec 0.2150 1 D 1000 16 0.19 m(abs) 1.9 0.00 m 0 0.930 m 9.1 0.000 m 0 2.039 m 20 0.250 m As 0.0491 0.3 m 2.943 0.00 m 0 -0.938 m -9.20178 0.000 m 0 52.090 m 511 0.200 m Ad 0.0314 -0.3 m -2.943

m3/sec kg/m3 o C kPa(abs) kPa(g) kPa kPa kPa m2 kPa kPa(g) kPa kPa kPa m2 kPa

Patm Pamb Vs Pinlet Hs Hs(r) Vd Poutlet Hd Hd(r) Htot Htot(r) NPSHa NPSHa(r)

SYSTEM CHARACTERISTICS 101.325 10.329 m 97.900 9.980 m 0.978 m 4.38 -2.669 m -26.180 1.991 m 19.531 2.969 m 29.123 2.387 m 6.84 51.452 m 504.741 53.539 m 525.216 51.152 m 501.798 55.53 54.12 7.79 6.82 m m m(abs) m(abs) 544.75 530.92 76.47 66.88

NPSHr Normally approx. 3% Htot =