FLUSHING GATES

*Estimation of Flushing gates Size based on Discharge* Assume Flushing flow =2X project flow Project Flow 20 cumecs Flow Depth Yo 4m 4 Discharge Qf Gate Width W Gate Height H 40 cumecs 4m 2m 2

Qf = 0.6 * 0.5 * (W)^2 * SQRT(2 * g * Yo)

Refer:-page 4 ,Standards Manuals/Guidelines for small hydro development,civil works (Guidelines for Hydraulic Design of small Hydro plants)

NO OF GATES
Max Flood Level MFL 103 Discharge Q 175 Width of gate W 5 Elevation of Gate sill 97.5 Zs Surcharge S 1.2 No of Length of over flow Section (m) gates 0 35 1 28 2 0 Cw for Gate Cw for Weir 1.7 1.8 m cumecs m m m QG QW QT

0 82.81565 82.81565 109.6385 66.25252 175.891 219.2769 0 219.2769