The stressing records are part of the structural design and serve as a basis for the stressing operation.

Besides the prestressing data, they contain sequence of stressing and directions for procedures directly connected with stressing operation, such as lowering of the formwork and releasing of bearings. calculation of strand tendon elongation at stressing The total elongation Itot which the tendon has to achieve during stressing should be calculated as:

Calculation Of Elongation

Itot = Ip + Ic + Isl + Ie

Ip = elongation of the strand tendon [mm]

Ip =

1 A p Ep

lp

lp

= length of tendon [m]


Po
1

lc
2

Px,0dx

Px,0 = P0 e- X = prestressing force at the stressing end [kN] P0


x

Px,0 = prestressing force of the tendon at any point distance x [kN]


Po Pe

= angle of deflection between the stressing end and at any point distance x [rad] =
180

aH2 + aV2 + | ]

Pe

= coefficient of friction (see p.5) = wobble angle (see p.5) = prestressing force at the stressing end after unintentional slip of elongation [kN]
le

Ic = elastic deformation of the concrete (shortening must be treated as a positive value) [mm]
cm l c

Ic =

Ec

cm

lc

= average stress in the concrete cross section at the centre of gravity of all tendons due to prestressing force [MN/m2] = length of the concrete member [m]

Isl = sum of anchor plates impressions and dead end wedge slip according anchorage type applied [mm]

lsl [mm]
accessible inaccessible

life end anchorage 1 -

dead end anchorage 4 3

Bond Head anchorage *)

Coupler R 3

Coupler D 6

Coupler M 3 -

*) see german approval Ie = elongation of the prestressing steel in the jack and seating device (if applicable) [mm] Calculation of life end prestressing force Pe [kN] and influence length le [m] due to life end wedge slip In [mm] at release of stressing jack In Ep Ap P0 1

Ie =

= average angle of deflection along the influence length l e of tendon


behind the life end [rad/m]

unintentional slip In [mm] Pe = P0 (1 - 2 le 1) at the life end anchorage at the coupler M

tendon type 6801 - 6807 6809 - 6827 6802 - 6812 *) with wedge seating standard case 4** 2* 8

jack type special case 2** 4 -

**) without wedge seating B 25 30,000 strand B 35 34,000 B 45 37,000 B 55 39,000

modulus of elasticity [N/mm2]

concrete class Ec

Ep = 195,000 [N/mm2] 12 24 16 32 20 40 24 48

required cube strength of the concrete at stressing acc. DIN 4227, part 1

partical prestressing full prestressing