HUAWEI BSC6000 Base Station Subsystem

BSC ALARMS LIST


155 All Ater LapdLink Faulty
Description This alarm is reported when all of the Ater Lapdlink are disrupted. Alarm ID Alarm Severity Alarm Type 155 Critical Fault

Possible Causes The E1/T1 links on the Ater interface are fault The interface boards are running abnormally. The configuration of the internal signaling links are modified.

160 HDLC Link Fault


Description This alarm is generated when the HDLC transmission is faulty. Attribute Alarm ID Alarm Severity Alarm Type 160 Minor Fault

Possible Causes The E1 port where the HDLC is configured is faulty. The board where the HDLC is configured is faulty. The interface board for BTS transmission is faulty.

Alcatel-Lucent Proprietary and Confidential

HUAWEI BSC6000 Base Station Subsystem

331 NSVC Faulty


Description The NSVC refers to the virtual connection at the NS layer of the Gb interface. This alarm is generated when the GEPUG is faulty, the NSVC is blocked, the bearer channel is inaccessible, or the configuration of the BSC and SGSN is faulty. Attribute Alarm ID Alarm Severity Alarm Type 331 Major Fault

Possible Causes The GEPUG is faulty. The NSVC is blocked. The bearer channel is inaccessible. The configuration of the BSC and SGSN is faulty.

332 NSVL Faulty


Description The NSVL refers to the virtual link on the IP NS layer of the Gb interface. This alarm is generated when the GFGUG is faulty, the network between the BSC and the SGSN is disconnected, or the configuration of the BSC and SGSN is faulty. Attribute Alarm ID Alarm Severity Alarm Type 332 Major Fault

Possible Causes The GFGUG is faulty; The IP communication between the BSC and the SGSN is disconnected; The configuration of the BSC and SGSN is faulty.

Alcatel-Lucent Proprietary and Confidential

HUAWEI BSC6000 Base Station Subsystem

333 NSE Faulty


Description NSE is the management entity on the NS layer. This alarm is generated when the Gb interface is abnormal. Attribute Alarm ID Alarm Severity Alarm Type 333 Critical Fault

Possible Causes The Gb interface is abnormal.

1000 LAPD OML Fault


Description The data link layer protocol between the BSC and the BTS is the LAPD protocol. To enable the communication between the data link layers of the BSC and the BTS through the LAPD protocol, the LAPD link should be established. The link carries operation and maintenance information is called OML, or LAPD_OML. This alarm is generated when the BSC detects the LAPD_OML disconnection between the BSC and the BTS or the BSC detects that the handshake with the BTS times out. Attribute Alarm ID Alarm Severity Alarm Type 1000 Critical Fault

Possible Causes The transmission device or transmission link between the BSC and the BTS is faulty. The Abis interfaced board of the BSC is faulty. The BTS experiences power failure. The TMU board or E1 lightning protection board of the BTS is faulty

Alcatel-Lucent Proprietary and Confidential

HUAWEI BSC6000 Base Station Subsystem

21002 Broken LAPD Link


Description This alarm is reported when the LAPD link cannot receive any message from the BTS or the PCU at the peer end. Attribute Alarm ID Alarm Severity Alarm Type 21002 Critical Fault

Possible Causes The network is unstable and the intermittent link is caused. The E1 cable is faulty. The BTS or the PCU at the peer end is faulty.

21205 Board Fault


Description This alarm is generated on the SCU in the GMPS when the communication between the board and the SCU in the GMPS is interrupted. Attribute Alarm ID Alarm Severity Alarm Type 21205 Critical Fault

Possible Causes If the GOMU is faulty, the possible causes are as follows: A pair of GOMUs is configured for the BSC, but only one GOMU is operating. A pair of GOMUs is configured for the BSC, but on the operating standby GOMU, the OMU software is stopped or the startup of the OMU software fails. A pair of GOMUs is configured for the BSC, but the standby GOMU is reset. A pair of GOMUs is configured for the BSC and the OMU software on the operating standby GOMU runs normally, but the communication link between the active GOMU and the standby GOMU is faulty. If the board other than the GOMU is faulty, the possible causes are as follows:

Alcatel-Lucent Proprietary and Confidential

HUAWEI BSC6000 Base Station Subsystem

If all boards in a subrack are faulty, the Ethernet cable between this subrack and the GMPS may be disconnected. If all boards in the TC subrack are faulty, the OML on the Ater interface may be disconnected or the Ethernet cable between the main subrack and the extension subrack may be disconnected. If an individual board in a subrack is faulty, the board may be manually removed from the subrack, switched over, or reset. If an individual board in a subrack is faulty, the board is reset because hardware or software fault occurs on the board.

21206 CPU Fault


Description This alarm is generated if the active CPU fails to detect the status of the standby CPU on a board that runs multiple CPUs, indicating that the CPU is not available. Attribute Alarm ID Alarm Severity Alarm Type 21206 Major Fault

Possible Causes The communication between the CPUs of the service boards is abnormal. The CPU is faulty.

21584 APS K1/K2 Mismatch Alarm


Description This alarm is reported when the ASP protection section uses different channels to send the K1 byte and to receive the K2 byte. Attribute Alarm ID Alarm Severity Alarm Type 21584 Major Fault

Alcatel-Lucent Proprietary and Confidential

HUAWEI BSC6000 Base Station Subsystem

Possible Causes This alarm is reported when the duration that ASP protection section uses different channels to send the K1 byte and to receive the K2 byte exceeds the five seconds.

21551 Ater OML Broken Alarm


Description This alarm is generated when the OML between the GEPS/GMPS and the GTCS is disconnected. Attribute Alarm ID Alarm Severity Alarm Type 21551 Critical Fault

Possible Causes The boards in the GTCS on the Ater interface are reset or faulty. The physical line carrying the OML on the Ater interface is faulty.

20087 High BER over the E1/T1 Link


Description This alarm is generated if the BSC detects that the bit error rate on the E1/T1 port is always greater than 5E-4 in one minute. This alarm is cleared if the BSC detects that the bit error rate on the E1/T1 port is always smaller than 1E-6 in one minute. Attribute Alarm ID Alarm Severity Alarm Type 20087 Major Fault

Possible Causes The link code of the port of the BSC interface board is inconsistent with that of the interface board of the peer NE. The E1/T1 cable of the BSC interface board is connected improperly. The clock source of the BSC and that of the peer equipment are different. The BSC subracks are grounded improperly.
Alcatel-Lucent Proprietary and Confidential

HUAWEI BSC6000 Base Station Subsystem

The transmission equipment or transmission link between the BSC and the peer equipment is faulty.

20231 Administration Unit Alarm Indication Signal (AUAIS)


Description Administration unit alarm indication. Attribute Alarm ID Alarm Severity Alarm Type 20231 Major Fault

Possible Causes No signal is detected between the peer equipment (BTS or BSC) and the transmission equipment, whereas the transmission equipment is normally connected with the local equipment.