IE RULES

RULE-29 COSTRUCTION, INSTALLATION, PROTECTECTION, OERATION AND MAINTENANCE OF ELECTRIC SYPPLY LINES AND APPARATUS. SUFFICIENT RATING, SUFFICIENT MECHANICAL STRANGTH UNDER EXISINT ENVIRONMENTAL CONDITION

BIS/ NATIONAL ELECTRIC CODE TO FOLLOWED FOR ALL OTHER ACTIVITIES.

BE

MATERIAL AND APPARATUS SHOULD BE IS MARK WHEREVER AVAILABLE.

SERVICE LINES AND APPARATUS ON CONSUMERS PREMISES.

RULE-31
CUT-OUT ON CONSUMERS PREMISES

RULE-32
IDENTIFICATION OF EARTHED AND EARTHED NEUTRAL CONDUCTORS AND POSITION OF SWITCHES AND CUTOUT THEREIN. PROPER IDENTI FICATION OF FARTH/NEUTRAL EARTHED CONDUCTOR REQUIRED NO ISOLATOR IN EARTH CONDUCTOR

RULE-33

EARTHED TERMINAL ON CONSUMERS PREMISES


RULE-34 ACCESSIBILITY OF BARE CONDUCTORS ENSURE THAT THEY ARE INACCESSIBLE PROVIDE ISOLATION SWITHES TO PRENDER THEM DEAD WYHENEVER REQUIRED RULE-35

DANGER NOTICES
FOR MEDIUM, HIGH EXTRA HIGH VOLTAGES IN HINDI & ENGLISH WITH A SIGN OF SKULL BONE

RULE-36
HANDLING OF ELECTRIC SUPPLY LINES AND APPARATUS FIRST EARTHING/ DISCHARGE ELECTRICITY BE FORE MAINTENANCE

NO UNAUTHORISED PERSON TO WORK ON LIVE LINE

RULE-37
SUPPLY TO VEHICLES, CRANES, ETC.

RULE-38 CABLES FOR APPARATUS PORTABLE OR TRANSPORTABLE

FLEXIBLE CABLE NOT TO BE USED FOR PORTABLE OR TRANSPORTABLE MOTORS, GENERATOR, TRANSPORMER, RECTIFIER, ELECTRICAL DRILL ETC. UNTILL HEAVILY INSULATED AND MECHANICALY PROTECTED METALLIC SHEATH OF CABLE SHALL BE CONNECTED WITH METALLIC FRAME 3 CORE CABLE FOR SINGLE PHASE CONNECTION AND 4 CORE CABLE FOR 3 PHASE CONNECTION

RULE-39
CABLES PROTECTED BY BITUMINOUS MATERIALS RULE-40

STREET BOXES

RULE-43
PROVISIONS APPLICABLE TO PROTECTIVE EQUIPMENT FIRST AID BOXES OR CUPBOARDS, CONSPICUOUSLY MARKED SHALL BE PROVIDED FOR ALL SUBSTATIONS.

RULE- 44
INSTRUCTIONS FOR RESTORATION SUFFEERING FROM ELECTRIC SHOCK OF PERSONS

INSTRUCTIONS IN (ENGLISH OR HINDI AND THE LOCAL LANGUAGE) FOR RESTORATION OF PERSONS SUFFERING FROM ELECTRIC SHOCK, SHALL BE AFFIXED IN A CONSPICUOUS PLACE IN EVERY GENERATING STATION, AND ENCLOSED SUB-STATION .

RULE-44A
INTIMATION OF ACCIDENT IF ANY ACCIDENT OCCURS IN ANY PART OF A ELECTRIC SUPPLY AND THE ACCIDENT RESULTS IN OR IS LIKELY TO HAE RESULTED IN LOSS OF HUMAN OR ANIMAL LIFE, OR IN ANY INJURY TO A HUMAN OR ANIMAL A TELEGRAPHIC REPORT WITHIN 24 HOURS AND A WRITTEN REPORT IN THE FORM SET OUT IN ANNEXURE XIII WITHIN 48 HOURS TO BE SEND TO THE LEECTRICAL INSPECTOR.

RULE- 61
CONNECTION OF EARTH THE FOLLOWING PROISIONS SHALL APPLY TO THE CONNECTION WITH EARTH FOR SYSTEMS AT LOW AND MEDIUM OLTAGE NEUTRAL CONDUCTOR OF A 3 PHASE, 4 WIRE SYSTEM SHALL BE EARTHED BY TWO SEPARATE AND DISTINCT CONNECTION WITH TWO DIFFERENT EARTH ELECTRODES

RULES- 61-A
EVERY ELECTRICAL INSTALLATION OTHER THAN LOW VOLTAGE INSTALLATION BELOW 2 KW SHALL BE CONTROLLED BY AN EARTH LEAKAGE PROTECTIVE DEVICE SO AS TO DISCONNECT THE SUPPLY INSTANTLY ON THE OCCURRENCE OF EARTH FAULT OR LEAKAGE OF CURRENT. THE FRAME, AND THE METALLIC PARTS (NOT INTENDED AS CONDUCTORS) OF ALL ELECTRICAL APPARATUS USED FOR REGULATING OR CONTROLLING ENERGY SHALL BE EARTHED BY TWO SPARATE AND DISTINCT CONNECTION WITH EARTH.