Вы находитесь на странице: 1из 119

SCANNER GUIDE

Version 6.00

2011 by Anite Finland Ltd. All rights reserved. This manual, as well as the software described in it, is furnished under license and may only be used or copied in accordance with the terms of such license. The information in this manual is intended for informational use only and is subject to change without notice. Anite Finland Ltd assumes no responsibility or liability for any errors or inaccuracies that may appear in this user manual. Except as permitted by such license, no part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Anite Finland Ltd. Windows, Windows XP, Windows Vista, Windows 7, Outlook, and Internet Explorer are registered trademarks of the Microsoft Corporation in the United States and other countries. MapInfo and MapX are registered trademarks of MapInfo Corporation. CDMA 2000 is a registered trademark of the Telecommunications Industry Association (TIA -USA). The license management portion of this Licensed Technology is based on SentinelLM* 1989-2003 Rainbow Technologies, Inc. All rights reserved.

Revision 6.00.01, Last edited July 2011

NEM O SCA NNER G UI DE


CONNECTING DEVICES Connecting Nemo FSR1 Scanner Connecting Anritsu Scanners Connecting the DRT Wimax 4301A+ Scanner 4 4 8 17 20

Connecting the PCTEL LX CDMA/EVDO/GSM/WCDMA Scanner Connecting PCTEL EX scanners 22

Connecting the PCTEL LX GSM/WCDMA Dual-Mode Scanner Connecting the PCTEL MX GSM/WCDMA Scanner Connecting PCTEL PCT Scanners 29 32

26

Connecting the Rohde & Schwarz TSMQ/TSML Scanner 35 Connecting the Rohde & Schwarz TSMW Scanner STARTING DEVICES Starting Nemo FSR1 Scanner Starting Anritsu Scanners Starting DRT Scanners Starting PCTEL Scanners Starting Rohde & Schwarz Scanners STARTING MEASUREMENT Nemo FSR1 Scanner Anritsu Scanners PCTEL Scanners DRT Scanners Rohde & Schwarz TSMQ/TSML/TSMW Scanners TROUBLESHOOTING SCANNERS 39 43 43 45 47 49 55 56 56 67 81 102 107 119

NEM O SCA NNER G UI DE

CONNECTING DEVICES
CONNECTING NEMO FSR1 SCANNER
Nemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone receiver is achieved by using the optional AC power supply. The AC power supply is designed to work with 100 - 240VAC 50/60Hz. For other voltages or line frequencies contact Anite for the correct supply.

The standard AC supply is rated at 130 Watts. Actual power requirements will vary depending number of downconverters installed and the receiver tasking. The maximum power requirement of the scanner is 50 Watts. DC operation for the standalone receiver can be achieved by connection to a vehicle 12-volt system. The following table is provided to budget the system current requirements for various configurations. Platform configuration/Module Basic system w/ single downconverter Two downconverter system 12 VDC current requirement 3.0 A 3.6 A

The estimates given for the scanner assume maximum utilization of the processing capabilities.

Connecting the Nemo FSR1:


1. Connect an antenna cable to scanner RF input. If you are measuring with two downconverters, connect an antenna in both RF inputs (see picture below).

NEM O SCA NNER G UI DE

2. Connect Ethernet cable(s) to the scanner Ethernet port(s) and to the Nemo Outdoor laptop. 3. Go to Control Panel | Network and Internet | Network and Sharing Center. Click on Change adapter settings.

4. Right-click on Local Area Connection and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol Version 4 (TCP/IPv4) and click Properties.

NEM O SCA NNER G UI DE

5. Select Use the following IP address and type in the IP address of the scanner in the IP address field. Click OK and Close.

Please note that by default the Nemo FSR1 is delivered with a fixed IP address. The IP address can be changed with a separate utility software. The following IP addresses are used in Nemo Outdoor: "Nemo Scanner LAN" = 192.168.3.253 "Nemo Scanner LAN 2" = 192.168.3.252 "Nemo Scanner LAN 3" = 192.168.3.251 "Nemo Scanner LAN 4" = 192.168.3.250

6. Connect the power cable to the scanner and to a power source. Switch power on. Fuse Fans

Power connector

Power switch

NEM O SCA NNER G UI DE

7. The default address and name settings of the scanner are generally suitable for most users. There is no need to configure these settings when using the Nemo FSR1 scanner with Nemo Outdoor. 8. The status LEDs at the front panel display how the scanner is functioning. LED Name RxA RxB Status Active All LEDs LED Color Green Amber Green Amber Green Amber Green Red Amber Description Receiver A enabled Receiver A disabled i.e. EEPROM not readable Receiver B enabled Receiver B disabled i.e. EEPROM not readable GPS Locked GPS Unlocked Ethernet link connected Ethernet link disconnected If all four LEDs are amber, the bootloader is running and the module needs to be reloaded

NEM O SCA NNER G UI DE

CONNECTING ANRITSU SCANNERS


These instructions apply to all Anritsu scanners, except Anritsu MS2721B DVB-H Analyzer. 1. Connect the antenna cable to scanner RF Input. If you are measuring with a dual-mode scanner that supports both GSM and WCDMA, use the RF1 input (see picture). RF2 input only supports WCDMA scanning.

2. Connect the battery cable to the battery and to a power source.

3. The Battery led of the scanner should turn green. The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12.

NEM O SCA NNER G UI DE

4. Connect the null modem cable to the scanner COM port that can be found below the power switch.

5. Connect the null modem to one of the PC COM ports 6. Turn the power on in the scanner. The Power led should light up. 7. The scanner should now start, wait until the scanner has started 8. Press the Menu button in the scanner. 9. Use the arrow keys and the Sel button to select Interface and Behavior. 10. Check that the settings are as follows. If not, change them using the arrow keys and the Sel button (note that the selected item will be underlined as soon as you use the arrow buttons to switch to another line). To exit the dialog without saving, press the F4 button (Cancel). To exit the dialog and save the modified settings, press the F5 button (OK). COM1 Protocol: Direct COM1 Baud Rate: 38400 or 57600 or 115200 COM1 Stop Bit(s): 1 COM1 Data Length: 8 COM1 Parity: None

The baud rate 115200 is the fastest option. Note! Memorize the baud rate. It is needed when starting the device. 11. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see the following steps.

NEM O SCA NNER G UI DE

10

12. Insert the Anritsu installation CD in your PC. 13. Connect the USB cable to the scanner USB port found in the front panel and to the PC. 14. Switch the scanner on. 15. The New Hardware Wizard will start automatically. Select the No, not this time option and click Next.

16. Select the Install the software automatically option and click Next.

NEM O SCA NNER G UI DE

11

17. If a warning message appears, click Continue Anyway. The installation will start. Please wait while the New Hardware Wizard installs the software. When the installation is complete, click Finish.

18. To check that the installation was successful, go to Device Manager (Start | Settings | Control Panel | System | Hardware | Device Manager). Expand the Universal Serial Bus controllers item. Area Scanner should be on the list.

NEM O SCA NNER G UI DE

12

19. Double-click on Area Scanner. Check that the Device Status field displays This device is working properly. Exit the dialog by clicking OK.

Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer Scanner
Installing the driver:
Please follow the following steps to install the NI-VISA 4.0 driver. 1. To install the driver the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Copy the executable file visa400full.exe to your local drive before installing the driver, and run the installation from the hard drive.

NEM O SCA NNER G UI DE

13

3. Double-click on the file and unzip the contents to your hard-drive. This may take a couple of minutes.

4. The installation starts automatically. 5. Click Next>> on the welcome page.

NEM O SCA NNER G UI DE

14

6. Select the destination folder for the driver and click Next>>.

7. Click Next>> in the Features dialog.

8. Select I accept the License Agreement(s) in the following page and click Next>>. 9. Click Next>> in the following dialog and wait for the installation to finish, and Finish in the Installation Complete dialog. Note that you may need to restart your computer for the installation to take effect.

NEM O SCA NNER G UI DE

15

10.Connect the scanner with your PC through a network cable. Insert one end of the network cable in the network cable connector in the scanner, and the other end to the network cable connector in your PC.

11.Next, you need to make some changes to your PCs network card properties. Go to Start | Control Panel | Network Connections, and right-click on Local Area Connection, and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) and click on Properties. Select Use the following IP address. You need to type in an IP address out of the range 192.168.0.11 - 192.168.0.14, as those addresses are reserved for the scanner. Type in, for example, 192.168.0.10. Next, type 255.255.0.0 in the Subnet mask field. Click OK and Close to exit the dialogs.

12. Next, start the scanner by pressing on the green On/Off button. 13. Press on Shift and then System (8) button on the scanner. 14. On the menu to the right of the screen, select System Options | Ethernet Config by using the grey buttons next to the screen.

NEM O SCA NNER G UI DE

16

15. Select the Set the IP Address Manually using the following Settings by pressing the topmost grey button immediately under the Esc button. 16. Type in the same IP address for both IP and Gateway from those reserved for the scanner (192.168.0.11 - 192.168.0.14). Here the selected IP address will be 192.168.0.14. You can move to different directions on the screen through the grey buttons. If the Subnet field is not automatically filled when filling the IP and Gateway fields, you can use, for example, 255.255.255.255 for it. Press Enter and restart the device by clicking twice on the On/Off button. 17. When the scanner has restarted, start Nemo Outdoor. Go to Measurement | Add device | Scanner, and select Anritsu MS2721B DVB-H or Anritsu MS2721B Spectrum Analyzer. Click Next. 18.In the Scanner Properties dialog that appears, select one of Anritsu LAN 1-4 ports depending on which IP address you entered on the device. If you entered 192.168.0.11, select Anritsu LAN 1, if you selected 192.168.0.12, select Anritsu LAN 2, etc. Since 192.168.0.14 was selected earlier, the Anritsu LAN 4 port will be used here.

Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so they can be left as they are. 19. Click OK. See page 77 for more information on how to perform DVB-H measurements. See page 77 for instructions regarding settings for the Spectrum Analyzer.

NEM O SCA NNER G UI DE

17

CONNECTING THE DRT WIMAX 4301A+ SCANNER


Note! The DRT 4301A+ scanner does NOT have an On/OFF switch. The unit is powered by connecting the power cable and powered off by disconnecting the power cable. When connecting cables to the unit, the power cable should be the last one connected and the first one disconnected. 1. Insert one end of the RJ-45 cable in the DATA jack in the scanner, and connect the other end with the PC. 2. Insert the power cable in the connector marked DC IN. 3. Plug the antenna cable in the FR IN B port in your DRT scanner. Note that you can only select one of the antennas, 2300/2500MHz or the 3500MHz antenna, and connect it with the scanner. You must select between the antennas at this point.

4. Connect the scanners GPS antenna cable to the scanners GPS port, and place the GPS antenna on a visible spot. 5. Go to Start | Control Panel | Network Connections on your PC. 6. Right-click on Local Area Connection and select Properties. 7. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) | Properties.

NEM O SCA NNER G UI DE

18

8. In the General tab, select Use the following IP address, and type 192.168.5.1 in the IP address field, and 255.255.255.0 in the Subnet mask field.

9. Click OK and Close to exit the dialogs. 10. Now connect the scanners power cable. The scanner is now on. A green light will turn on in the scanner.

11. Start Nemo Outdoor. Go to Measurement | Add New Device | Scanner. Select DRT WIMAX 2300, DRT WIMAX 2500 or DRT WIMAX 3500 depending on which band you choose to measure at the time.

NEM O SCA NNER G UI DE

19

12. In the Scanner Properties dialog, select DRT LAN in the Port drop-down menu.

Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so they can be left as they are. 13. Click OK to exit the dialog. 14. Go to page 102 for more information on conducting WIMAX measurements with the DRT scanner.

NEM O SCA NNER G UI DE

20

CONNECTING THE PCTEL LX CDMA/EVDO/GSM/WCDMA SCANNER


1. Connect the antenna cable to the scanner RF Input.

2. Connect the scanner GPS antenna cable to the scanner GPS input (above RF Input).

NEM O SCA NNER G UI DE

21

3. Connect the scanner power cable to the scanner serial port (Data).

4. The scanner cable is split into a serial cable connector and a power cable connector. Connect the serial cable to one of the COM ports in the PC. Connect the scanner power cable to a cigarette lighter in the car. 5. When connecting the scanner power cable, check the Power led: If the led is first orange for a while and then turns green, the scanner is working properly and using a baud rate of 38400 If the led blinks orange and black for a while and then turns green, the scanner is working properly and using baud rate of 115200 If the led is red, the scanner is not working properly. Switch the power off and on again. If this occurs after usage, the device may be overheated. Let it cool down for a while.

Note! Memorize the baud rate. It is needed when starting the device.

Connecting External GPS to PCTEL LX EVDO/GSM/WCDMA Scanner


Note that you cannot use both the integrated and an external GPS receiver at the same time. 1. Connect the GPS serial cable to a PC serial port.

If there is only one port in the PC by default, this port should be reserved for the scanner. In this case connect the GPS to the PCMCIA serial port adapter. 2. Connect the GPS power cable to a cigarette lighter.

NEM O SCA NNER G UI DE

22

CONNECTING PCTEL EX SCANNERS


Installing the SeeGull EX VCP Device Driver
Please follow the following steps to install the VCP device driver. 1. To install the driver the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Copy the folder /SeeGull EX VCP driver_v.2.0.0.46B to your local drive before installing the driver, and run the installation from the hard drive. Right click on the folder and select Properties. Clear the Read-only attributes and click OK. Select Apply changes to this folder, subfolder and files as below and click OK.

3. Double-click on the SeeGull EX VCP Device Driver.msi installer file to start the driver installation. 4. Click Next in the SeeGull Welcome window that appears. 5. Select the destination folder for the driver in the Destination Folder window, and Click Next, and click Install.

NEM O SCA NNER G UI DE

23

6. Click Finish in the InstallationShield Wizard Completed window to exit the wizard.

7. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front panel.

NEM O SCA NNER G UI DE

24

8. Connect the power cable to the Power connector in the front panel. Connect the other end of the cable to a cigarette lighter socket. The SYS indicator in the front panel will light up.

9. Connect the antenna cables. It does not matter which antenna cable goes to which RF connector.

NEM O SCA NNER G UI DE

25

10. Connect the GPS antenna to the connector marked GPS.

11. Connect the USB data cable to the USB port in the front panel. Connect the other end of the USB data cable to your PC.

12. Windows will automatically detect the device.

NEM O SCA NNER G UI DE

26

CONNECTING THE PCTEL LX GSM/WCDMA DUAL-MODE SCANNER


1. Remove the yellow plastic caps from the antenna and GPS connectors in the front panel.

2. Connect the power cable to the Power and Data connector in the front panel. Connect the other end to a USB port on your computer and to a power source. The green Power indicator in the scanner front panel will light up.

NEM O SCA NNER G UI DE

27

3. Connect the antenna cables. Note that the antenna cables and the connectors in the scanner front panel are color coded. The OP042 cable marked with yellow is connected to the RF1 connector marked with yellow (connector on the left). The OP039 cable marked with blue is connected to the RF2 connector marked with purple (connector in the middle).

4. Connect the GPS antenna to the connector marked GPS (connector on the right).

5. Windows will have detected the new device and will install the required drivers. Insert the PCTEL installation CD. 6. Select No, not this time in the Welcome dialog.

NEM O SCA NNER G UI DE

28

7. Select Install from a list of specific location and click Next.

8. Select Include this option in the search and browse to folder D:\EdgeportUSB\Edgeport Vendor Data\driver vx.x. Click Next to start the installation.

9. When the installation is finished, click Finish. Windows will automatically install some additional drivers and report when the device is ready to be used.

NEM O SCA NNER G UI DE

29

CONNECTING THE PCTEL MX GSM/WCDMA SCANNER


Installing the SeeGull MX Device Driver
Please follow the following steps to install the device driver. 1. To install the driver the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Browse to folder seegull mx driver\MX winusb driver. For 32-bit operating system run DPInst.exe from install x86 folder and for 64-bit operating system run DPInst.exe from install x64 folder. 3. The PCTEL USB Device Installer window will appear. Click Next. 4. If a Windows Security message appears, click Install. 5. Click Finish in the installation completed window. 6. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front panel.

NEM O SCA NNER G UI DE

30

7. Connect the power cable to the PWR connector in the front panel. Connect the other end of the cable to a cigarette lighter socket. The Status indicator in the front panel will light up.

8. Connect the antenna cables. The label on the scanner lists the frequencies of the radio modules connected to each specific port, labeled RF1 to RF8. The antenna ports that require antenna connections are identified by their frequency on the label. Since each SeeGull MX is configured to minimize the number of ports necessary for use, some ports may be inactive for a particular configuration and are indicated by a blank box.

NEM O SCA NNER G UI DE

31

9. Connect the GPS antenna to the connector marked GPS. 10. Connect the USB data cable to the USB port in the front panel. Connect the other end of the USB data cable to your PC.

11. Windows Vista and Windows 7 will automatically detect and install the device. 12. With Windows XP a Found new Hardware window will appear. Select No, not this time in the Welcome window. Select Install the software automatically (Recommended) and click Next. Finally click Finish. 13. Go to Start | Control Panel | System | Hardware | Device Manager and select Ports. Memorize the port number for the PCTEL Communications Port item, as you will need it later on.

NEM O SCA NNER G UI DE

32

CONNECTING PCTEL PCT SCANNERS


Installing PL2303 Prolific DriverInstaller Driver
1. Run the PL2303_Prolific_DriverInstaller_vx.x.exe (x refers to the version number) file on the installation CD. 2. Click Next in the Welcome window that appears. 3. Click Finish to finish the driver installation. 4. Next, remove the yellow plastic caps from the antenna and GPS connectors in the front panel of the PCTEL PCT scanner.

5. Connect the antenna cable in the RF Input connector.

NEM O SCA NNER G UI DE

33

6. Connect the data cable to the Data connector. Connect the other end of the USB data cable to your PC.

7. Connect the power cable to the Power connector in the front panel. Connect the other end of the cable to a cigarette lighter socket.

8. Windows automatically detects the new hardware.

NEM O SCA NNER G UI DE

34

9. Go to Start | Control Panel | System | Hardware | Device Manager and select Ports. Memorize the port number for the Prolific USB-to-Serial Comm Port item, as you will need it later on.

NEM O SCA NNER G UI DE

35

CONNECTING THE ROHDE & SCHWARZ TSMQ/TSML SCANNER


Note that your PC must have a FireWire (IEEE1394) port in it and a 32-bit PC FireWire controller card for you to be able to connect a Rohde & Schwarz TSMQ Scanner

Driver installation:
1. First, install the TSMxDriverInstall.exe file on the installation CD. 2. Click Run to run the installation file.

3. Click Next in the Welcome window that appears.

NEM O SCA NNER G UI DE

36

4. Next, connect the antenna cable to the RF Input connector in the Rohde & Schwarz scanner.

5. Connect the FireWire cable to one of the IEEE ports and the other end to your PC or a FireWire adapter in the PC.

NEM O SCA NNER G UI DE

37

6. Next, connect the power cable to the DC IN connector and the other end to a power source.

7. Windows automatically detects the new hardware. Select No, not this time and click Next in the Welcome window that appears.

NEM O SCA NNER G UI DE

38

8. Select Install the software automatically (Recommended), and click Next.

9. Click Finish to finish the installation. 10. Go to Device Manager from Start | Control Panel | System | Hardware | Device Manager. You should see the Rohde & Schwarz TSMx Devices item, and the applicable Rohde & Schwarz scanner model under it.

NEM O SCA NNER G UI DE

39

CONNECTING THE ROHDE & SCHWARZ TSMW SCANNER


1. First, connect antenna cables to the RF1 and RF2 input connectors. See chapter System Priority Order with R&S TSMW Scanners on page 41 for information on connecting the antennas to the correct ports.

NEM O SCA NNER G UI DE

40

2. Next, connect the network cable connector to the LAN connector in the scanner. Note that the network port in the computer to which the cable is connected should be at least 1 Gbps.

3. Connect the power cable to the DC IN port in the scanner, and the other end of the cable to a power source.Connect the power cable either to a Mascot power supply, or with the applicable cigarette lighter adapter, to a cigarette lighter socket.

NEM O SCA NNER G UI DE

41

4. Next, you need to make some changes to your PCs network card properties. Go to Start | Control Panel | Network Connections, and right-click on Local Area Connection, and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) and click on Properties. Select Use the following IP address. You need to type in an IP address within the range of 192.168.0.1 - 192.168.0.255. The default IP address for the scanner is 192.168.0.2, so it should be avoided. Next, type 255.255.255.0 in the Subnet mask field. Click OK and Close to exit the dialogs. 5. In Windows 7, go to Start | Control Panel | Network and Internet | Network and Sharing Center. Select Local Area Connection in the View your active networks list. In the Local Area Connection Status dialog, select Properties. In the Local Area Connection Properties dialog that opens, select the Networking tab, and Internet Protocol Version 4 (TCP/IPv4) in the This connection uses the following items view. Click on Properties. Select Use the following IP address. You need to type in an IP address within the range of 192.168.0.1 192.168.0.255. The default IP address for the scanner is 192.168.0.2, so it should be avoided. Next, type 255.255.255.0 in the Subnet mask field. Click OK and Close to exit the dialogs. 6. The device is now connected to the computer. See Starting Devices below for information on how to connect the scanner with Nemo Outdoor.

System Priority Order with R&S TSMW Scanners


Multiple cellular technologies (systems) are measured in a parallel manner. The different systems are arranged in a priority order as shown in Figure 4. The CDMA and EVDO systems are counted as one system. Nemo Outdoor handles priority and allocates the RF ports automatically. In this case priority refers to the order in which systems are allocated to RF port #1 and RF port #2. The resource slot number defines in how many processes one RF port is divided. Both ports, RF #1 and RF #2, have 100% of available resources. When only one system (except LTE) is measured, for example WCDMA, it is set to be measured via RF port #1 with 100% of its resources. When two systems are measured simultaneously, for example GSM and WCDMA, GSM has higher priority over WCDMA. GSM is set to be measured via RF port #1 with 100% of its resources, whereas WCDMA system is set to be measured via RF port #2 with 100% of its resources.

NEM O SCA NNER G UI DE

42

When three systems are measured simultaneously, for example GSM, WCDMA and CDMA, the systems are again allocated in the priority order for the two RF ports. In this case RF port #1 is shared by two systems: GSM and CDMA. Each system gets 50% of the RF port #1 resources. 100% of RF port #2 resources are allocated to WCDMA measurements. With LTE, individual carriers are allocated to the two RF ports. For example, when measuring two or more LTE carriers, carriers are arranged in order from lowest frequency number to the highest. After that, carriers (frequencies) are allocated to the RF ports so that the first carrier is allocated to RF port #1 and the second carrier to RF port #2, third carrier is again allocated to RF port #1 and the fourth carrier to RF port #2, etc. If the measurement setup includes an odd number of other systems in addition to LTE, the first LTE carrier is allocated to RF port #2. The second LTE carrier is allocated to RF port #1, etc. However, if the measurement setup includes only one other system in addition to LTE, the other system is allocated to RF port #1 and all LTE carriers are allocated to RF port #2. Spectrum scanning is counted as one of the systems. Spectrum scanning always has the highest priority and it is set to be measured via RF port #1. The resource slot number defines in how many processes one RF port is divided.

NEM O SCA NNER G UI DE

43

STARTING DEVICES
Starting Nemo Outdoor:
1. Start Nemo Outdoor from the Start menu, Nemo Tools submenu. 2. Do not load any previous device configuration if asked.

STARTING NEMO FSR1 SCANNER


1. From the Measurement menu, select Add New Device. 2. Click on Scanner. 3. From the list select Nemo FSR1 and click Next.

4. In the Scanner Properties dialog, select Nemo Scanner LAN as the Port and click OK.

NEM O SCA NNER G UI DE

44

5. If the dialog did not close, the startup did not succeed. Check the cable connections and the settings and try again. 6. If the Device Status window is not visible, open it from the View menu. A green light should be blinking. This means that the device is working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work Offline/Online button ). If the device is started but not scanning, check that you have selected channels to be scanned.

NEM O SCA NNER G UI DE

45

STARTING ANRITSU SCANNERS


1. From the Measurement menu, select Add New Device. 2. Click on Scanner. 3. From the list select: For Anritsu ML8720B: Anritsu ML8720B UMTS 2100 and click Next. For Anritsu ML8720C without the GSM option: Anritsu ML8720C UMTS 2100 and click Next. For Anritsu ML8720C with the GSM option: Anritsu ML8720C GSM/UMTS and click Next. For Anritsu ML8740A and Anritsu ML8740B without the GSM option: Anritsu ML8740A/ ML8740B UMTS 2100 and click Next. For Anritsu ML8740A and Anritsu ML8740B with the GSM option: Anritsu ML8740A/ML8740B GSM/UMTS and click Next. For Anritsu MS2721B DVB-H Analyzer: Anritsu MS2721B DVB-H, and click Next. For Anritsu MS2721B Spectrum Analyzer: Anritsu MS2721B Spectrum Analyzer, and click Next.

4. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to (ML8720B/ML8720C)/select the USB port (e.g., Anritsu USB1)/or select the Anritsu LAN 1-4 with Anritsu MS2721B DVB-H depending on which IP address was selected for the scanner. The next step is not valid for the Anritsu ML8740A, Anritsu ML8740B, Anritsu MS2721B DVB-H, or Anritsu MS2721B Spectrum Analyzer scanner.

NEM O SCA NNER G UI DE

46

5. Set the baud rate to the one used by the scanner and click OK. Note that the baud rate must be the same that you chose when you were connecting the scanner. The dialog will be closed and the scanner should now be connected to the system. 6. If the dialog did not close, the startup did not succeed. Check the cable connections and the settings and try again. 7. If the Device Status window is not visible, open it from the View menu. A green light should be blinking. This means that the device is working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work Offline/Online button ).

NEM O SCA NNER G UI DE

47

STARTING DRT SCANNERS


1. From the Measurement menu, select Add New Device. 2. Click on Scanner. 3. From the list select: DRT WIMAX 2300, if you want to make measurements with the 2300 MHz (WiMAX) band. DRT WIMAX 2500, if you want to make measurements with the 2500MHz (WiMAX) band. DRT WIMAX 3500, if you want to make measurements with the 3500MHz (WiMAX) band.

NEM O SCA NNER G UI DE

48

4. In the Scanner Properties dialog, set the COM Port to DRT LAN.

Note that the no changes need to be made to the Baud rate, Antenna gain, and Cable loss fields. See the next chapter for further instructions on how to make measurements.

NEM O SCA NNER G UI DE

49

STARTING PCTEL SCANNERS


Starting the GPS:
With the PCTEL LX WCDMA scanner you can use either the GSP receiver integrated into the scanner or an external GPS. See page 51 for instructions on how to enable the integrated GPS receiver. Note that you cannot use both the integrated and an external GPS receiver at the same time. Note that with the PCTEL LX GSM/WCDMA scanner the Internal GPS receiver should be activated only in UMTS mode. To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix at least 30 seconds before starting the Nemo Outdoor application in online mode. If the existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the configuration file in offline mode. If scanner does not send any results after 30 seconds, it is advised to send a reset command to the scanner via the user interface. 1. From the Measurement menu, select Add New Device. 2. Click on GPS. 3. From the list, select the GPS model that you have connected to the PC and click Next. 4. The GPS Properties dialog is opened. Set the parameters (see the GPS User Manual for instructions). They should be correct by default. Click OK. The view will return to the Nemo Outdoor main window. 5. In the Device Status window a green light should be blinking. This means that the GPS is working properly.

Starting the PCTEL LX/EX/PCT GSM/WCDMA/1xEV-DO/LTE Scanner:


1. From the Measurement menu, select Add New Device. 2. Click on Scanner. 3. From the list select: For PCTEL LX UMTS 1700/2100 scanner: PCTEL LX UMTS 1700/2100, and click Next. For PCTEL LX UMTS 1900 scanner: PCTEL LX UMTS 1900, and click Next. For PCTEL LX UMTS 2100 scanner: PCTEL LX UMTS 2100, and click Next. For PCTEL LX UMTS 850/1900 scanner: PCTEL LX UMTS 850/1900, and click Next.. For PCTEL LX UMTS 850 scanner: PCTEL LX UMTS 850, and click Next.. For PCTEL LX CDMA/EV-DO 850 scanner, select PCTEL LX EVDO 800, and click Next. For PCTEL EX WCDMA 2100 AWS&GSM 850/ 1900 scanner: PCTEL EX GSM 850/1900 UMTS AWS, and click Next. For PCTEL LX 1xEV-DO 450 scanner: PCTEL LX EVDO 450, and click Next.

NEM O SCA NNER G UI DE

50

For PCTEL LX 1xEV-DO 850 scanner: PCTEL LX EVDO 800, and click Next. For PCTEL LX 1xEV-DO 1900: PCTEL LX EDVO 1900, and click Next. For PCTEL EX CDMA/EV-DO 850/1900 scanner, select CDMA2000 850/1900 EVDO 850/1900, and click Next. For PCTEL EX GSM 850/1900 & WCDMA 850/1900 scanner: PCTEL EX GSM 850/1900 UMTS 850/1900, and click Next. For PCTEL EX GSM 900/1800 & WCDMA 900/2100 scanner: PCTEL EX GSM 900/1800 UMTS 900/2100, and click Next. For PCTEL PCTEL EX GSM 1900 & WCDMA 2100 AWS scanner: PCTEL EX GSM 1900 UMTS AWS, and click Next.. For PCTEL EX WIMAX scanner: PCTEL EX WIMAX, and click Next. For PCTEL EX 900/1800 WCDMA/TD-SCDMA 2000, select PCTEL EX 900/1800 UMTS TDSCDMA 2000, and click Next. For PCTEL EX LTE 1800/2600 scanner, select PCTEL EX LTE 1800/2600, and click Next. For PCTEL EX LTE 2100 scanner, select PCTEL EX LTE 2100, and click Next. For PCTEL EX LTE 2100/2600 scanner, select PCTEL EX LTE 2100/2600, and click Next. For PCTEL EX LTE 700ABC scanner, select PCTEL EX LTE 700ABC, and click Next. For PCTEL EX LTE 700C scanner, select PCTEL EX LTE 700C, and click Next. For PCTEL EX LTE AWS/700BC scanner, select PCTEL EX LTE AWS/700BC, and click Next. For PCTEL EX LTE AWS/700C scanner, select PCTEL EX LTE AWS/700C, and click Next. PCTEL EX mini series scanners: o o o o For WCDMA 2100, select PCTEL EX UMTS 2100, and click Next... For WCDMA 850/1900, select PCTEL EX UMTS 850/1900, and click Next... For WCDMA 900/2100, select PCTEL EX UMTS 900/2100, and click Next... For WCDMA AWS, select PCTEL EX UMTS AWS, and click Next...

For PCTEL MX scanners, select PCTEL MX and click Next. For PCTEL PCT GSM 900/1800 scanner, select PCTEL PCT GSM 900/1800, and click Next. For PCTEL PCT UMTS 2100 scanner, select PCTEL PCT UMTS 2100, and click Next.

NEM O SCA NNER G UI DE

51

4. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to. With MX scanners, select the PCTEL USB item. 5. Set the baud rate to the one used by the scanner and click OK. The dialog will be closed and the scanner should now be connected to the system. 6. If the dialog did not close, the start-up did not succeed. Check the cable connections and the settings and try again. 7. From the View menu activate Device Status. A check mark will appear next to the command when it is activated. 8. A green light on the PCTEL scanner in the Device Status window should be blinking. This means that the device is working properly and scanning using the default settings. See chapter Starting Measurement (page 56) for instructions on making your own scanner configuration.

Enabling integrated GPS receiver for PCTEL LX WCDMA/PCTEL EX WiMAX scanner


1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog click the Advanced button.

NEM O SCA NNER G UI DE

52

3. In the Advanced Properties dialog, select Yes for the Enable Integrated GPS Receiver option and click OK.

4. The integrated GPS receiver is now enabled. Note that you cannot use both the integrated and an external GPS receiver at the same time. Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be activated only with UMTS mode. To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix at least 30 seconds before starting the Nemo Outdoor application in online mode. If the existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the configuration file in offline mode. If scanner does not send any results after 30 seconds, it is advised to send a reset command to the scanner via the user interface.

NEM O SCA NNER G UI DE

53

Starting the PCTEL LX GSM/WCDMA dual-mode scanner


1. From the Measurement menu, select Add New Device. Click on Scanner. 2. From the list select PCTEL LX GSM 900/1800 and click Next.

3. In the Scanner Properties dialog, Port field you should see two consecutive COM ports (e.g., COM 3 and COM 4). Select the COM port with the smaller number and click OK. 4. From the Measurement menu, select Add New Device. Click on Scanner. 5. From the list select PCTEL LX UMTS 2100 and click Next. 6. In the Scanner Properties dialog, Port field you should see two consecutive COM ports (e.g., COM 3 and COM 4). Select the COM port with the bigger number and click OK. 7. A green light should be blinking in the Device Status for both devices. This means that the devices are working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work Offline/Online button ). 8. The GSM and UMTS scanners will appear as separate devices and must be configured individually.

Enabling integrated GPS receiver for PCTEL LX GSM/WCDMA dual-mode scanner


Note that with the PCTEL dual-mode scanner the integrated GPS receiver needs to be enabled only for one scanner. 1. After the PCTEL LX scanners are connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties.

NEM O SCA NNER G UI DE

54

2. In the Measurement Properties dialog click the Advanced button. 3. In the Advanced Properties dialog, select Yes in the Enable Integrated GPS Receiver option and click OK.

4. The integrated GPS receiver is now enabled. Note that you cannot use both the integrated and an external GPS receiver at the same time. Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be activated only with UMTS mode.

NEM O SCA NNER G UI DE

55

STARTING ROHDE & SCHWARZ SCANNERS


1. Start Nemo Outdoor. From the Measurement menu, select Add New Device. 2. Click on Scanner. 3. From the list select the applicable R&S scanner, and click Next..

4. In the Scanner Properties dialog, select R&S IEEE1394A in the Port drop-down menu. Click OK.

5. A green light should be blinking in the Device Status for both devices. This means that the devices are working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work Offline/Online button ).

NEM O SCA NNER G UI DE

56

STARTING MEASUREMENT
NEMO FSR1 SCANNER
Frequency Scanning
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog you can select the channels to be scanned. 3. On the Frequency scanning, GSM page, click the Select Channels button to select the GSM channels to be scanned.

Channel style defines the style of the measured channel. For GSM the option is 200 kHz. Data mode defines the type of measurement data computed from each sample. Note that the available selection depends on the scanner type. RX Level Average: the data reported is the average RX level, in dB, of the number of samples.

Measurement period defines the time in milliseconds for which the scanner measures and then reports the result.

NEM O SCA NNER G UI DE

57

Sample size defines the number of samples taken from each channel before a measurement result is written to file. Selecting the BSIC decoding option displays BSIC value in a measurement window. BSIC threshold defines the minimum BSIC level that the scanner reports. Select the BCCH C/I option to activate C/I measurements for the BCCH channel. 4. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - UMTS


Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N pilot mode/scanning.

To set pilot scanning settings:


1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are below the threshold, the pilots are not reported.

NEM O SCA NNER G UI DE

58

Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow Band (200kHz) and Wide Band (3.84MHz). Correlator affects how the scanner works. Bigger correlator size enables the scanner to detect and measure pilot channels with better dynamic but makes scanning speed slower. For example, when using correlator size 2048 versus 512, the dynamic range for pilot measurement changes from 21db to 17db. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Measurement period defines the time in milliseconds for which the scanner measures and then reports the result. Pilot measurement mode defines the measurement mode for pilot scanning. In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode, weak pilots may be undetected. In High dynamic mode scanning speed is lower but sensitivity is higher.

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. The maximum number is 32. Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID information can be decoded from BCCH messages. Note that this is only enabled in online mode and if the option has been purchased with the scanner. Cell information decoding is supported only in WCDMA. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning.

NEM O SCA NNER G UI DE

59

To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N Configuration button. The Select Channels dialog is opened.

2. The table displays the channel numbers, not the frequencies. 3. You can remove channels from the Selected list by selecting a channel and clicking the Remove button. 4. You can add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. 5. Click OK to return to the Measurement Properties dialog. 6. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 7. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 8. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

60

TOP-N Pilot Scanning - CDMA/EVDO


Note that the EVDO measurements can only be performed in a proper way when a CDMA2000 channel is measured as well. In this way, the time relationship between the different PN offsets is resolved. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning, CDMA page.

Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the threshold, the pilots are not scanned. Top-N mode option enables/disables TOP-N scrambling code scanning. Number of pilots field defines how many pilots are reported by the scanner in TOP-N mode. Overhead message decoding, when selected, enables the scanner to decode PCH messages. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. Note that the Nemo FSR1 scanner supports max 32 channels.

NEM O SCA NNER G UI DE

61

3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning LTE


1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.

Sync signal refers to the ratio between the synchronization channel, i.e., primary and secondary signal received power and the interference and noise from the same synchronization signal set. Reference signal refers to the ratio between the reference signal received power (RSRP) and the interference and noise from the same reference signal set.

NEM O SCA NNER G UI DE

62

The Select Channels button will open the Select Channels dialog where you can select channels for pilot scanning. When you select LTE channels, you can also define some channel-specific settings. In the LTE Channel Specific Settings dialog, select the channel from the Selected channels list and define the settings. Note that the available options are device specific.

Uplink-downlink configuration refers to LTE TDD frame structure. Frame structure type 2 is applicable to TDD. Each radio frame of length Tf 307200 Ts 10 ms consists of two half-frames of length 153600 Ts 5 ms each. Each half-frame consists of five subframes of length 30720 Ts 1 ms . The supported uplink-downlink configurations are listed in the table below where, for each subframe in a radio frame, D denotes the subframe is reserved for downlink transmissions, U denotes the subframe is reserved for uplink transmissions and S denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One radio frame , T f = 307200 T s = 10 ms One half -frame, 153600 Ts = 5 ms

One slot,

T slot=15360 Ts
Subframe #0 One subframe , 30720 Ts DwPTS

30720T s

Subframe #2

Subframe #3

Subframe #4

Subframe #5

Subframe #7

Subframe #8

Subframe #9

GP

UpPT S

D wPTS

GP

UpPT S

NEM O SCA NNER G UI DE

63

Frame structure type 2 (for 5 ms switch-point periodicity):


Uplink-downlink configuration 0 1 2 3 4 5 6 Downlink-to-Uplink Switch-point periodicity 5 ms 5 ms 5 ms 10 ms 10 ms 10 ms 5 ms 0 D D D D D D D 1 S S S S S S S 2 U U U U U U U Subframe number 3 4 5 6 7 U U D S U U D D S U D D D S U U U D D D U D D D D D D D D D U U D S U 8 U U D D D D U 9 U D D D D D D

3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

64

Spectrum Analyzer Measurements


1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page. Select the Enable spectrum scanning option and click on Add.

NEM O SCA NNER G UI DE

65

3. Define the start and stop frequencies within which the measurement will be performed. If you manually define the start and stop frequencies, you can either select to add the frequencies to the scanning list or save them as a predefined set. Select your option in the Add to scanning list menu. 4. Select Set center frequency and bandwidth to define the center frequency and the bandwidth to be measured. If you manually define the center frequency and bandwidth, you can either select to add them to the scanning list, or save them as a predefined set. Select your option in the Add to scanning list menu.

It should be noted that resolution bandwidths with FSR1 scanner devices are fixed. Currently supported values are: 1875, 3750, 7500, 15000, 30000, 60000 and 120000 kHz. 5. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in the Measurement Properties dialog can increase the scanners measuring sensitivity, hence slightly decreasing background noise. However, it is recommended that it is not selected when signal volume is higher than -50dBm.

NEM O SCA NNER G UI DE

66

6. You can add scanning sets in the Predefined scanning sets field through the Add to Scanning List button. Click the arrow in the button and select Save as Predefined Set. Define a name in the Enter Frequency Set Name field and click OK.

7. The name appears in the Predefined scanning sets field along with the chosen frequency and/or bandwidth information selected in the Reporting field. 8. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 9. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 10. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

67

ANRITSU SCANNERS
Frequency Scanning
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog you can select the channels to be scanned: If the scanner supports only one carrier, you can select either GSM or UMTS channels to be scanned. If the scanner supports two carriers, you can select for scanning both GSM and UMTS channels. If you select GSM channels, you can select a maximum of one UMTS channel. If you do not select GSM channels, you can select one or two UMTS channels.

3. On the Frequency scanning, GSM page, click the Select Channels button to select the GSM channels to be scanned. Note that the scanner reports the 32 strongest channels from the selected GSM channels.

Channel style defines the style of the measured channel. For GSM the options are 200 kHz and 30 kHz narrow.

NEM O SCA NNER G UI DE

68

Data mode defines the type of measurement data computed from each sample. Note that the available selection depends on the scanner type. RX Level Average: the data reported is the average RX level, in dB, of the number of samples. RX Level Maximum: the data reported is the maximum RX level, in dB, of the number of samples. RX Level Minimum: the data reported is the minimum RX level, in dB, of the number of samples. RX Level Standard Deviation: the data reported is the standard of deviation of the number of samples reported as an integer. RX Level 10%: the data reported is the 10th percentile RX level, in dB, of the number of samples. RX Level 50%: the data reported is the 50th percentile RX level, in dB, of the number of samples. RX Level 90%: the data reported is the 90th percentile RX level, in dB, of the Number of samples.

Measurement period defines the time in milliseconds for which the scanner measures and then reports the result. Sample size defines the number of samples taken from each channel before a measurement result is written to file. Selecting the BSIC decoding option displays BSIC value in a measurement window. BSIC Threshold defines the minimum BSIC level that the scanner reports. BCCH C/I option is available with PCTEL and Rohde&Schwarz GSM scanners only. 4. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

69

TOP-N Pilot Scanning - UMTS


Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode/Scanning.

To set pilot scanning settings:


1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page.

Note that some of the options are enabled/disabled in this dialog according to the selected scanner model. Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow Band (200kHz) and Wide Band (3.84MHz). For Anritsu scanners, only Wide Band is available. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Measurement period defines the time in milliseconds for which the scanner measures and then reports the result.

NEM O SCA NNER G UI DE

70

Number of fingers defines the maximum number of fingers used for RAKE in measurement. Selective level determines a valid path. Set a value (in dB) to decide a valid path from the noise floor (average value). Rake threshold determines a valid path (in dB). Subtracting the set value from a path with a maximum correlation value gives the lower limit of the valid path. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. Delay profile option enables/disables delay profile scanning. The Channel number field provides a list of channels that can be selected for scanning. Finger option enables and disables Finger measurements for the scanner. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. If you press the arrow, a drop-down menu will appear from where you can select Top-N Search Configuration.

Please note that the Top-N Search Configuration dialog is available for Anritsu UMTS scanners only.

NEM O SCA NNER G UI DE

71

In the Top-N Search Configuration dialog you can limit the search performed by the scanner and consequently speed up the search.

Group specifies the group number for the primary scrambling code in the range of 0 to 63. Cell specifies the cell number for the primary scrambling code in the range of 0 to 7. Secondary code specifies the secondary scrambling code. Limit range should be set from 0 to 0. Channelization code specifies the channelization code. Limit range should be set from 0 to 0. Search method defines how the search is performed. P-CPICH (primary common pilot channel) searches with P-CPICH. SCH performs a three-step search with P-SCH and S-SCH.

To select pilot parameters:


1. Select the TOP-N Mode option. 2. Set the Number of Scrambling codes value. This defines how many strongest pilots are to be reported by the scanner. The maximum is 32 pilots.

NEM O SCA NNER G UI DE

72

To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N Configuration button. The Select Channels dialog is opened.

2. The table displays the channel numbers, not the frequencies. With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be selected. 3. You can remove channels from the Selected list by selecting a channel and clicking the Remove button. 4. You can add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. 5. Click OK to return to the Measurement Properties dialog.

NEM O SCA NNER G UI DE

73

To select search parameters:


1. Open the Measurement Properties, Pilot scanning, UMTS page. Press down the Top-N Configuration button and select Top-N Search Configuration.

2. The Top-N Search Configuration dialog opens.

NEM O SCA NNER G UI DE

74

3. Set the Group search range. The group number is the scrambling code divided by 8. For example, SC (scrambling code) 12 = group 1, cell 4. 4. Set the Cell search range. The cell number is the division modulus. For example, SC (scrambling code) 12 = group 1, cell 4. 5. The Secondary Code and the Channelization Code ranges should be set from 0 to 0 for scanning only the P-CPICH. 6. Select the Search Method. SCH means that the P-CPICH are searched using P-SCH and S-SCH. P-CPICH means that the P-CPICH are searched without using P-SCH and S-SCH. Note that the P-CPICH method is much slower than the SCH method. 7. Click OK to accept the settings and to return to the Measurement Properties dialog. 8. Data processing method defines how the scanner will process samples before reporting. 9. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data processing method is used. In pilot scanning mode, the RSSI is always measured for each channel. In pilot scanning mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 10. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 11. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 12. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

75

Pilot Scrambling Code Scanning


Pilot Scrambling Code Scanning or Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal Pilot Mode. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Measurement Properties, Pilot scanning, UMTS page .

3. Clear the TOP-N mode option and click the Select Channels button. The Select Scrambling Codes dialog is opened. 4. Select channels in the Selected channel numbers table by clicking the Select button. With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be selected. 5. For each selected channel, select scrambling codes. Select a channel and click the Select button below the Selected scrambling codes table. 6. Click OK to return to the Measurement Properties dialog.

NEM O SCA NNER G UI DE

76

7. When using an Anritsu scanner in Pilot Scanning mode, you can define the measurement period. It defines the time period from which results are gathered and processed before reporting. 8. Data processing method defines how the scanner will process samples before reporting. In Pilot Scanning Mode the RSSI is always measured for each channel. In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 9. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 10. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 11. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

77

DVB-H Scanning
DVB-H scanning can be performed with the Anritsu MS2721B DVB-H Analyzer scanner. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties, Pilot scanning, DVB-H page, select a frequency to be measured. Anritsu MS2721B DVB-H Analyzer scans frequencies between (DVB-H) 474 850 MHz.

3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 5. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

78

Spectrum Analyzer Measurements


Spectrum scanning can be performed with the Anritsu MS2721B Spectrum Analyzer scanner. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page.

NEM O SCA NNER G UI DE

79

3. Select the Enable spectrum scanning option and click on Add.

4. Define the start and stop frequencies within which the measurement will be performed. If you manually define the start and stop frequencies, you can either select to add the frequencies to the scanning list or save them as a predefined set. Select your option in the Add to scanning list menu. 5. Select Set center frequency and bandwidth to define the center frequency and the bandwidth to be measured. If you manually define the center frequency and bandwidth, you can either select to add them to the scanning list, or save them as a predefined set. Select your option in the Add to scanning list menu. With Anritsu MS2721B spectrum analyzer the supported frequency range is from 9 kHz to 7.1GHz. The sample count is fixed to 551, and RBW is adjusted automatically. RBW is between 1 Hz - 3 MHz. It is automatically adjusted to the closest value of 1 Hz, 3 Hz, 10 Hz, 30Hz, 100 Hz ... 300 kHz, 1 MHz, 3 MHz. 6. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in the Measurement Properties dialog can increase the scanners measuring sensitivity, hence slightly decreasing background noise. However, it is recommended that it is not selected when signal volume is higher than -50dBm.

NEM O SCA NNER G UI DE

80

7. You can add scanning sets in the Predefined scanning sets field through the Add to Scanning List button. Click the arrow in the button and select Save as Predefined Set. Define a name in the Enter Frequency Set Name field and click OK.

8. The name appears in the Predefined scanning sets field along with the chosen frequency and/or bandwidth information selected in the Reporting field. 9. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 10. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 11. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

81

PCTEL SCANNERS
Frequency Scanning PCTEL GSM/UMTS Scanners
Frequency scanning can be used to scan band power. It is also useful for checking that the band is deselected and for finding out the center frequency. 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Frequency scanning, UMTS page.

3. In the Channel style field, select the channel width. The options are narrow band (200 kHz) and wide band (3.84 MHz). To find out the center frequency used, set the Channel Style to 200 kHz and select all the channels in the frequency region where the carrier should exist; for example, all channels allocated to an operator. The center frequency will stand out in Frequency Scanning mode. The received signal should be above the noise level in order to find out the center frequency.

NEM O SCA NNER G UI DE

82

4. Click the Select Channels button to open the Select Channels dialog.

5. The table displays the channel numbers, not the frequencies. 6. Remove channels from the Selected list by selecting a channel and clicking the Remove button. 7. Add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. 8. Click OK to return to the Measurement Properties dialog. 9. Click OK and OK to close the Measurement Properties dialog and to re-start the scanner with the new settings. 10. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 11. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

83

Frequency Scanning PCTEL EX LTE Scanner


1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. By clicking the Advanced button on the General page, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 2. On the Frequency scanning page, define the Channel style.

NEM O SCA NNER G UI DE

84

3. By clicking the Select Channels button, you can access the Select Channels dialog.

4. Select one band from the list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All | ...items from current band. The Available view provides a list of channels that are available for scanning. To add channels to the Selected list, click on a number in the Available list and then click the Add button or simply double-click a channel to add it to the Selected list. To select all available channels for scanning, click the Add All button. An alternative method to select channels is to type the channel numbers in the field at the bottom of the dialog and to click Add. To remove channels from the Selected list, click on the channel you want to remove and then click the Remove button or double-click the channel. To remove all channels, click the Remove All button. You can select several channels simultaneously by holding down the SHIFT key and clicking on the channels you want to add or remove. 5. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 6. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 7. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

85

Frequency Scanning PCT GSM Scanner


1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 3. Go to the Frequency scanning page.

Channel style refers to the style of the channel. Selecting the BSIC decoding option displays BSIC value in a measurement window. BSIC threshold defines the minimum BSIC level that the scanner reports. Select the BCCH C/I option to activate C/I measurements for the BCCH channel. This option is available with PCTEL GSM scanners only.

NEM O SCA NNER G UI DE

86

4. By clicking the Select Channels button, you can access the Select Channels dialog.

5. Select one band from the list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All | ...items from current band. The Available view provides a list of channels that are available for scanning. To add channels to the Selected list, click on a number in the Available list and then click the Add button or simply double-click a channel to add it to the Selected list. To select all available channels for scanning, click the Add All button. An alternative method to select channels is to type the channel numbers in the field at the bottom of the dialog and to click Add. To remove channels from the Selected list, click on the channel you want to remove and then click the Remove button or double-click the channel. To remove all channels, click the Remove All button. You can select several channels simultaneously by holding down the SHIFT key and clicking on the channels you want to add or remove. Note that Sample size and Data mode are not enabled with PCT GSM frequency scanning

NEM O SCA NNER G UI DE

87

6. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 7. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 8. Click the Start Recording button to start recording the results in an output file.

Frequency Scanning PCTEL EVDO Scanners


1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 3. Go to the Frequency scanning page.

Channel style refers to the style of the channel. For EV-DO scanners, the options are 1250 kHz Normal and 30 kHz Normal. Sample size defines the number of samples taken from each channel before a measurement result is written to file.

NEM O SCA NNER G UI DE

88

4. By clicking the Select Channels button, you can access the Select Channels dialog.

5. Select one band from the list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All | ...items from current band. The Available view provides a list of channels that are available for scanning. To add channels to the Selected list, click on a number in the Available list and then click the Add button or simply double-click a channel to add it to the Selected list. To select all available channels for scanning, click the Add All button. An alternative method to select channels is to type the channel numbers in the field at the bottom of the dialog and to click Add. To remove channels from the Selected list, click on the channel you want to remove and then click the Remove button or double-click the channel. To remove all channels, click the Remove All button. You can select several channels simultaneously by holding down the SHIFT key and clicking on the channels you want to add or remove. 6. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 7. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 8. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

89

TOP-N Pilot Scanning - UMTS


Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode. 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Pilot scanning page.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are below the threshold, the pilots are not reported. Channel style refers to the style of the channel. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Pilot measurement mode defines the measurement mode for pilot scanning. In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode, weak pilots may be undetected. In High dynamic mode scanning speed is lower but sensitivity is higher.

NEM O SCA NNER G UI DE

90

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. Time of arrival defines if the selected scanner will measure the time of arrival for each scrambling code. The time of arrival value is relative to GPS time and is measured in chips. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code.

To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N Configuration button. The Select Channels dialog is opened.

The table displays the channel numbers, not the frequencies. If you know the frequency but not the channel number, the channel number can be calculated by multiplying the frequency in MHz by five. The channel spacing is always 200 kHz. 2. Remove channels from the Selected list by selecting a channel and clicking the Remove button. 3. Add channels to the Selected list by selecting a channel from the Available list and clicking the Add button.

With a PCTEL LX scanner a maximum of 8 channels can be selected in the pilot mode. With a PCTEL EX scanner a maximum of 15 channels can be selected in the pilot mode. With a PCTEL MX scanner 1 channel can be selected in the pilot mode. With a PCTEL LTE EX scanner a maximum of 15 channels can be selected in the pilot mode. With a PCTEL PCT scanner a maximum of 4 channels can be selected in the pilot mode. 4. Click OK to return to the Measurement Properties dialog.

To select pilot parameters:


1. Select the TOP-N Mode option. 2. Set the Number of scrambling codes value. This defines how many strongest pilots are to be reported by the scanner. The maximum is 32 pilots.

Note that with the PCTEL PCT Scanner the maximum number of pilots to be selected for scanning is 8.

NEM O SCA NNER G UI DE

91

Note that the PCTEL EX WCDMA scanner only supports the TOP-N mode. You can select up to 32 pilots for scanning. 3. To improve on the accuracy of radio propagation models, High speed mode makes it possible to acquire more samples (max 32 pilots per channel), while High dynamic mode offers fewer samples (max 16 pilots per channel) with a larger dynamic range.

To set general parameters:


1. Data processing method defines how the scanner will process samples before reporting. 2. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data processing method is used.

To select measured values:


In Pilot Scanning Mode the RSSI is always measured for each channel. In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 1. In the Measurement Properties, Pilot scanning page: Select the P-SCH option to enable P-SCH Ec/N0 and RSCP measurement. Select the S-SCH option to enable S-SCH Ec/N0 and RSCP measurement. Select the Time of arrival option to enable time of arrival measurement. Select the Delay spread option to enable P-CPICH delay spread measurement. Select the SIR option to enable P-CPICH SIR measurement. Select the Delay profile option to enable P-CPICH Delay Profile measurement. In TOPN pilot scanning mode the scrambling code for delay profile measurement cannot be selected. 2. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 3. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 4. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - EVDO


Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode. 1. After the PCTEL LX/EX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data.

NEM O SCA NNER G UI DE

92

3. In the Measurement Properties dialog, go to Pilot scanning page.

Channel style refers to the style of the channel. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Pilot window mode defines the position of the chips that are searched for pilot across in regard to the ideal pilot position (0 chip delay for a given pilot). Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1, 1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every th th second sample is logged, with ratio 1:4 every 4 sample is logged, and with ratio 1:8 every 8 sample is logged. By decreasing the sampling ratio you can decrease the output file size, but the scanning accuracy will be diminished. Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the threshold, the pilots are not scanned. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode.

NEM O SCA NNER G UI DE

93

Delay option enables/disables delay profile scanning. Delay is defined as the measured difference between the expected arrival time (GPS time) and the actual arrival time of the maximum peak above the PN threshold. It is reported in chips. 4. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 5. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 6. Click the Start Recording button to start recording the results in an output file.

Spectrum Scanning
Spectrum scanning is enabled on PCTEL EX scanners only in online mode. Hence, the device needs to be added to Nemo Outdoor in online mode to activate the Spectrum scanning functionality 1. After the PCTEL EX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page.

NEM O SCA NNER G UI DE

94

3. Select the Enable spectrum scanning option, and click Add.

4. To create new scanning sets, define the scanning frequencies in the Reporting view. Set start and stop frequencies defines the frequency range that will be scanned. Set center frequency and bandwidth defines the frequency range that will be scanned. The Sample count field determines the sample count measured for the given frequency range. 5. The Add to Scanning List menu enables you to decide whether the new scanning set is added to the scanning list, or saved as a predefined set also for later use. 6. The Predefined scanning sets can be used to quickly select the frequency range to be scanned. Select a set from the list, and click on Add to Scanning List. With PCTEL EX scanning receivers, the internal frequency range is defined with start frequency, resolution bandwidth (RBW) and number of points. Stop frequency = start frequency + (frequency spacing) * (number of points 1). All the points need to be within the frequency range of the requested RF Band. Frequency spacing is between the center frequencies and spacing between points is half of the resolution bandwidth. The maximum number of samples (points) is 2560. As seen in the formula above, stop frequency is calculated based on start frequency and number of points. Stop frequency set by the user is only requested value but it is not necessarily used during the measurement.

NEM O SCA NNER G UI DE

95

If the requested frequency range is not supported by the device, Nemo Outdoor automatically adjusts the frequency range for the device, and only frequency ranges supported by the scanning receiver are used to make spectrum analyzer measurements. The number of samples is used only for the frequency range supported by the scanning receiver. Nemo Outdoor does not read the supported frequency range from the scanning receiver. For example, in the picture below the user has set start and stop frequencies as seen within the red area. However, the scanning receiver supports only frequency ranges shown by the green areas. The number of samples is used only for green areas and the correct RBW is selected accordingly.

7. Click OK to return to the Spectrum scanning page.

NEM O SCA NNER G UI DE

96

8. The added frequency ranges will be added to the Scanning list.

9. To remove items from the scanning list, select one or more, and select Remove All | Remove Selected Items. Alternatively, click on Remove All to remove every item from the list. 10. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 11. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 12. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

97

LTE OFDM Scanning


OFDM scanning can be used for scanning Reference signal / Sync signals with a PCTEL LTE scanner and Nemo Outdoor. 1. After the PCTEL LTE scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 3. In the Measurement Properties dialog, go to the Pilot scanning page.

Channel style refers to the style of the channel. Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect selected, the scanner will automatically detect the appropriate signal type. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

NEM O SCA NNER G UI DE

98

Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1, 1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every th th second sample is logged, with ratio 1:4 every 4 sample is logged, and with ratio 1:8 every 8 sample is logged. By decreasing the sampling ratio you can decrease the output file size, but the scanning accuracy will be diminished. RSSI threshold determines a valid path (in dB). Subtracting the set value from a path with a maximum correlation value gives the lower limit of the valid path. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best cells. Number of cells field indicates the number of best cells you want the scanning to notify you of. Up to 16 sectors are reported with specific cell ID. CINR option activates/deactivates Carrier to Interference and Noise Ratio measuring. Carrier refers to either reference signal power or sync signal power depending on the selected signal type. Time offset refers to the number of samples between P-SCH Primary Synchronization Signal arrival time with respect to receiver frequency reference that is derived from GPS reference time. Sync signal refers to the ratio between the synchronization channel, i.e., primary and secondary signal received power and the interference and noise from the same synchronization signal set. Reference signal refers to the ratio between the reference signal received power (RSRP) and the interference and noise from the same reference signal set. The Top-N Configuration button will open the Select Channels where you can select channels for pilot scanning. The maximum number of channels that can be selected is device specific.

NEM O SCA NNER G UI DE

99

4. When you select LTE channels, you can also define some channel-specific settings. In the LTE Channel Specific Settings dialog, select the channel from the Selected channels list and define the settings. Note that the available options are device specific.

Uplink-downlink configuration refers to LTE TDD frame structure. Frame structure type 2 is applicable to TDD. Each radio frame of length Tf 307200 Ts 10 ms consists of two half-frames of length 153600 Ts 5 ms each. Each half-frame consists of five subframes of length 30720 Ts 1 ms . The supported uplink-downlink configurations are listed in the table below where, for each subframe in a radio frame, D denotes the subframe is reserved for downlink transmissions, U denotes the subframe is reserved for uplink transmissions and S denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One radio frame , Tf = 307200 Ts = 10 ms One half -frame, 153600 Ts = 5 ms

One s lot,

Tslo t=15360 Ts
Subframe #0 One subframe , 30720 Ts D wPTS

30720 Ts

Subframe #2

Subframe #3

Subframe #4

Subframe #5

Subframe #7

Subframe #8

Subframe #9

GP

UpPT S

D wPTS

GP

UpPT S

Frame structure type 2 (for 5 ms switch-point periodicity):


Uplink-downlink configuration Downlink-to-Uplink Switch-point periodicity 0 1 2 Subframe number 3 4 5 6 7 8 9

NEM O SCA NNER G UI DE


0 1 2 3 4 5 6 5 ms 5 ms 5 ms 10 ms 10 ms 10 ms 5 ms D D D D D D D S S S S S S S U U U U U U U U U D U U D U U D D U D D U D D D D D D D S S S D D D S U U U D D D U U U D D D D U U D D D D D D

100

5. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 6. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 7. Click the Start Recording button to start recording the results in an output file.

Pilot Scrambling Code Scanning


Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal Pilot Mode. 1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page.

NEM O SCA NNER G UI DE

101

3. Clear the TOP-N mode option and click the Select Channels button. The Select Scrambling Codes dialog is opened. 4. Select channels in the Selected channel numbers table by clicking the Select button. With a PCTEL scanner a maximum of 8 channels can be selected in the pilot mode. 5. For each selected channel, select scrambling codes. Select a channel and click the Select button below the Selected scrambling codes table. 6. Click OK to return to the Measurement Properties dialog. 7. Data processing method defines how the scanner will process samples before reporting. 8. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data processing method is used. In Pilot Scanning Mode the RSSI is always measured for each channel. In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 9. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 10. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 11. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

102

DRT SCANNERS
Frequency Scanning
Frequency scanning can be used to scan band power. It is also useful for checking that the band is deselected and for finding out the center frequency. 1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. You can enable or disable the integrated GPS receiver through the Advanced button. It is also possible to use an external GPS device with the scanner. 3. In the Measurement Properties dialog, go to the Frequency scanning page.

4. In the Channel Style list box, select the channel width. The options are Wide Band (5000 kHz) and Wide Band 2 (10000 kHz).

NEM O SCA NNER G UI DE

103

5. Click the Select Frequencies button to open the Select Frequencies dialog.

6. The table displays the available frequencies. Select and add them in the Selected view by clicking on Add>>. 7. Remove frequencies from the Selected list by selecting a frequency and clicking the Remove button. 8. Add frequencies in the Selected list by selecting a frequency from the Available list and clicking the Add button. 9. Click OK to return to the Measurement Properties dialog. 10. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 11. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 12. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

104

Pilot Scanning
1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page.

Channel style refers to the style of the channel. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. Top-N option enables/disables TOP-N scrambling code scanning. If enabled, scanner will report results from N best preambles. Number of preambles field defines how many preambles are reported by the scanner in TOP-N mode. CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is based on the requested reuse factor. Preamble delay refers to the number of samples between expected arrival time and actual arrival time of preamble with respect to GPS time reference. The values range from 0 to 1023+32. Each sample corresponds to 89.285 nanoseconds.

NEM O SCA NNER G UI DE

105

Reuse factor refers to a system design parameter that can be manipulated to achieve the desired balance between the interference and the network coverage. The WiMAX air interface modulating waveform has been divided into three segments (Segment 0, 1 and 2). The allocation of frequency sub-carrier into these three segments is done in such a way that e.g. a downlink signal on segment 0 will not interfere with the downlink signal on segment 1. In a Reuse Factor 1 measurement, contributions from all the three segments are considered in the measured parameters, so that the CINRs are calculated from all the three segments. When Reuse Factor 3 is selected, only the contribution of the desired segment is considered, and the CINRs are calculated only from the same segment. As a broad guideline, measurements performed with Reuse Factor 1 will provide the signal quality of the all the detected preambles relative to each other, whereas the Reuse Factor 3 category of measurements will provide the signal quality of preambles within the same segment. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. 3. The Top-N Configuration button will open the Select Frequencies dialog where you can select frequencies for scanning. The maximum number of frequencies that can be selected is device specific.

NEM O SCA NNER G UI DE

106

4. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 5. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 6. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

107

ROHDE & SCHWARZ TSMQ/TSML/TSMW SCANNERS


With Rohde & Schwarz TSMQ, TSML and TSMW scanners you can perform GSM frequency scanning, GSM/UMTS scanning, CDMA TOP-N Pilot scanning, EVDO TOP-N Pilot scanning, UMTS TOP-N Pilot scanning, and Spectrum scanning. In addition, it is possible to perform CW scanning measurements with the TSMQ and TSML scanners and LTE measurements with the TSMW scanner. It is possible to perform any of the measurements introduced below separately, any combination of the measurements or all of them simultaneously.

Frequency Scanning
1. After the Rohde & Schwarz TSMQ/TSML scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties.

Selecting the BSIC decoding option displays BSIC value in a measurement window. BSIC threshold defines the minimum BSIC level that the scanner reports.

NEM O SCA NNER G UI DE

108

Select the BCCH C/I option to activate C/I measurements for the BCCH channel. This option is available with the PCTEL GSM scanner only. Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID information can be decoded from BCCH messages. Note that this is only enabled in online mode and if the option has been purchased with the scanner. When the System information decoding option is selected, L3 messages are written in the log file. 2. Click the Select Channels button to open the Select Channels dialog.

3. The table displays the channel numbers, not the frequencies. 4. Select one band from the Band list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All |...items from current band. 5. Remove channels from the Selected list by selecting a channel and clicking the Remove button. 6. Add channels to the Selected list by selecting a channel from the Available list and clicking the Add button.

NEM O SCA NNER G UI DE

109

7. Click OK to return to the Measurement Properties dialog. 8. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 9. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 10. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - UMTS


1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Pilot scanning, UMTS page to define UMTS-specific Pilot scanning settings.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are below the threshold, the pilots are not reported. Channel style refers to the style of the channel.

NEM O SCA NNER G UI DE

110

Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Pilot measurement mode defines the measurement mode for pilot scanning. In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode, weak pilots may be undetected. In High dynamic mode scanning speed is lower but sensitivity is higher.

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. Note that the Rohde & Schwarz TSMQ, TSML-W, TSML-GW and TSMW scanners support only TOP-N mode and High speed and High dynamic pilot measurement modes. In addition, Data processing method and CPICH Ec/N0 threshold are supported general settings, and P-SCH, S-SCH, Time of arrival, Delay spread and SIR are supported of the scanning options. Time of arrival defines if the selected scanner will measure the time of arrival for each scrambling code. The time of arrival value is relative to GPS time and is measured in chips. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. When the Missing neighbor detection option is selected, the missing neighbor information event (NMISS) is written in the log file. You can view the missing neighbor information, for example, in a grid view. When the Neighbor list decoding option is selected, the NLIST (neighbor list) event is written in the log file for both GSM and WCDMA. Delay profile option enables/disables delay profile scanning. The Channel number field provides a list of channels that can be selected for scanning. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code. When the System information decoding option is selected, L3 messages are written in the log file. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. Note that with UMTS the maximum number of channels that can be scanned is 32 channels, and the maximum number of pilots per each channel is 32.

NEM O SCA NNER G UI DE

111

3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - CDMA/EVDO


Note that the EVDO measurements can only be performed in a proper way when a CDMA 2000 channel is measured as well. In this way, the time relationship between the different PN offsets is resolved. 1. After the Rohde & Schwarz TSMQ scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot Scanning, CDMA page.

Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the threshold, the pilots are not scanned.

NEM O SCA NNER G UI DE

112

TOP-N mode option enables/disables TOP-N scrambling code scanning. Number of pilots field defines how many pilots are reported by the scanner in TOP-N mode. Overhead message decoding, when selected, enables the scanner to decode PCH messages. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. Note that the Rohde & Schwarz TSMQ scanner supports max 32 channels. 3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

113

TOP-N Pilot Scanning - LTE


1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.

CINR option activates/deactivates Carrier to Interference and Noise Ratio measuring. Carrier refers to either reference signal power or sync signal power depending on the selected signal type. Sync signal refers to the ratio between the synchronization channel, i.e., primary and secondary signal received power and the interference and noise from the same synchronization signal set. Reference signal refers to the ratio between the reference signal received power (RSRP) and the interference and noise from the same reference signal set.

NEM O SCA NNER G UI DE

114

The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. When you select LTE channels, you can also define some channel-specific settings. In the LTE Channel Specific Settings dialog, select the channel from the Selected channels list and define the settings. Note that the available options are device specific.

Uplink-downlink configuration refers to LTE TDD frame structure. Frame structure type 2 is applicable to TDD. Each radio frame of length Tf 307200 Ts 10 ms consists of two half-frames of length 153600 Ts 5 ms each. Each half-frame consists of five subframes of length 30720 Ts 1 ms . The supported uplink-downlink configurations are listed in the table below where, for each subframe in a radio frame, D denotes the subframe is reserved for downlink transmissions, U denotes the subframe is reserved for uplink transmissions and S denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One radio frame , T f = 307200 T s = 10 ms One half -frame, 153600 Ts = 5 ms

One slot,

T slot=15360 Ts
Subframe #0 One subframe , 30720 Ts DwPTS

30720T s

Subframe #2

Subframe #3

Subframe #4

Subframe #5

Subframe #7

Subframe #8

Subframe #9

GP

UpPT S

D wPTS

GP

UpPT S

NEM O SCA NNER G UI DE

115

Frame structure type 2 (for 5 ms switch-point periodicity):


Uplink-downlink configuration 0 1 2 3 4 5 6 Downlink-to-Uplink Switch-point periodicity 5 ms 5 ms 5 ms 10 ms 10 ms 10 ms 5 ms 0 D D D D D D D 1 S S S S S S S 2 U U U U U U U Subframe number 3 4 5 6 7 U U D S U U D D S U D D D S U U U D D D U D D D D D D D D D U U D S U 8 U U D D D D U 9 U D D D D D D

3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

116

Spectrum Scanning
1. After the Rohde & Schwarz scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page.

NEM O SCA NNER G UI DE

117

3. In the Measurement Properties dialog, select the Enable spectrum scanning option. Click Add.

4. To create new scanning sets, define the scanning frequencies in the Reporting view. Set start and stop frequencies defines the frequency range that will be scanned. Set center frequency and bandwidth defines the frequency range that will be scanned. The Sample count field determines the sample count measured for the given frequency range. With Rohde & Schwarz scanner receivers, the user can set the start and stop frequency between 80MHz and 3000MHz. Sample counts are divided to the frequency range defined by the user. The TSMx device has a native frequency resolution of 12.8 KHz. It should be noted that the frequency shift cannot be lower than 12.8kHz, which sets the number of sample count max. limit to 5000 samples. In case the selected frequency range and sample count require a frequency shift lower than 12.8kHz, the sample count is automatically decreased. The sweep speed, resolution bandwidth and sampling rate are fixed. The sweep speed is 1 GHz / 0.1 sec, the resolution bandwidth is fixed at 30 kHz. For example, if the start frequency is 80 MHz, and the stop frequency is 100 MHz, the total measured bandwidth is 20 MHz. If the sample count is set to 20, power (RMS) is measured from a 1 MHz bandwidth. With the frequency shift of 12.8 KHz ~ 78 samples are taken from each 1 MHz bandwidth.

NEM O SCA NNER G UI DE

118

The Add to scanning list menu enables you to decide whether the newly created scanning set is added to the scanning list, or saved as a predefined set also for later use. The Predefined scanning sets can be used to quickly select the frequency range to be scanned. Select a set from the list, and click on Add to scanning list. 5. Click OK to access the Scanning list view. 6. The added frequency ranges will be added to the Scanning list. 7. To remove items from the scanning list, select one or more, and select Remove all | Remove selected items. Alternatively, click on Remove all to remove every item from the list. 8. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 9. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 10. Click the Start Recording button to start recording the results in an output file.

NEM O SCA NNER G UI DE

119

TROUBLESHOOTING SCANNERS
If a Scanner synchronization failed error message appears in the Output window, the scanner is working properly, but the scanner did not find strong enough a CPICH in a short time period. Nevertheless, the measurement will go on normally. If a Scanner GPS locking failed error message appears in the Output window, the scanner is working properly, but the scanner GPS has no fix or is not connected. The measurement will go on normally, but the scanner accuracy is not as good as it is when the scanner GPS has a fix

Вам также может понравиться