Вы находитесь на странице: 1из 9

BAV99...

Silicon Switching Diode


For high-speed switching applications
Series pair configuration

BAV99
BAV99F
BAV99T
BAV99W

BAV99S
BAV99U

6
3

4
5

D 3
D 1

D 1

D 4

D 2

D 2

Type

Package

Configuration

Marking

BAV99
BAV99F*
BAV99S
BAV99T
BAV99U
BAV99W

SOT23
TSFP-3
SOT363
SC75
SC74
SOT323

series
series
dual series
series
dual series
series

A7s
A7s
A7s
A7s
A7s
A7s

* Preliminary

Mar-10-2004

BAV99...
Maximum Ratings at TA = 25C, unless otherwise specified
Parameter

Symbol

Value

Diode reverse voltage

VR

80

Peak reverse voltage

VRM

85

Forward current

IF

200

Non-repetitive peak surge forward current

IFSM
4.5

t = 1 ms

t = 1 s, single

0.5

t = 1 s, double

0.75

mA

mW

Ptot

BAV99, T S 28C

330

BAV99F, TS tbd

250

BAV99S, TS 85C
BAV99T, TS 104C

250

BAV99U, TS 113C

250

BAV99W, TS 110C

250

250

Junction temperature

Tj

Storage temperature

Tstg

Thermal Resistance
Parameter

Symbol

Junction - soldering point1)

RthJS

150

-65 ... 150

Value

Unit
K/W

BAV99

360

BAV99F

tbd

BAV99S

260

BAV99T

185

BAV99U

150

BAV99W

160

1For

t = 1 s

Total power dissipation

Unit

calculation of RthJA please refer to Application Note Thermal Resistance

Mar-10-2004

BAV99...
Electrical Characteristics at TA = 25C, unless otherwise specified
Symbol
Values
Unit
Parameter
min.
typ. max.
DC Characteristics
85
V
Breakdown voltage
V(BR)
I(BR) = 100 A
Reverse current

IR

VR = 70 V

0.15

VR = 25 V, TA = 150 C

30

VR = 70 V, TA = 150 C

50

Forward voltage

mV

VF

IF = 1 mA

715

IF = 10 mA

855

IF = 50 mA

1000

IF = 100 mA

1200

IF = 150 mA

1250

Electrical Characteristics at TA = 25C, unless otherwise specified


Symbol
Values
Unit
Parameter
min.
typ. max.
AC Characteristics
1.5 pF
Diode capacitance
CT
VR = 0 V, f = 1 MHz
Reverse recovery time

trr

ns

IF = 10 mA, IR = 10 mA, measured at IR = 1mA,


RL = 100
Test circuit for reverse recovery time
D.U.T.

Pulse generator: tp = 100ns, D = 0.05,


tr = 0.6ns, Ri = 50

Oscillograph

Oscillograph: R = 50, tr = 0.35ns


C 1pF

EHN00019

Mar-10-2004

BAV99...
Reverse current IR = (TA)

Forward Voltage VF = (TA)


IF = Parameter

VR = Parameter
10 5

BAV 99

1.0

nA

VF

EHB00078

F = 100 mA

10 4

IR

10 mA
10 3

1 mA

0.5

0.1 mA

70 V
25 V
10 2

10 1
0

25

50

75

100

150

TA

50

100

Forward current IF = (VF)

Forward current IF = (T S)

TA = 25C

BAV99

150

BAV 99

C
TA

150

250

EHB00076

mA

F mA
200
175

IF

100

typ

150
125

max

100

50

75
50
25

0.5

1.0

0
0

1.5

15

30

45

60

75

90 105 120 C

150

TS

VF

Mar-10-2004

BAV99...
Forward current IF = (T S)

Forward current IF = (T S)

BAV99S

BAV99T

250

250
mA

200

200

175

175

IF

IF

mA

150

150

125

125

100

100

75

75

50

50

25

25

0
0

15

30

45

60

75

90 105 120 C

0
0

150

15

30

45

60

75

90 105 120 C

TS

Forward current IF = (T S)

Forward current IF = (T S)

BAV99U

BAV99W

250

250

mA

mA

200

200

175

175

IF

IF

150

TS

150

150

125

125

100

100

75

75

50

50

25

25

0
0

15

30

45

60

75

90 105 120 C

0
0

150

TS

15

30

45

60

75

90 105 120 C

150

TS

Mar-10-2004

BAV99...
Permissible Puls Load RthJS = (tp)

Permissible Pulse Load

BAV99

IFmax / I FDC = (t p)
BAV99
10 2

I Fmax/IFDC

10

RthJS

10 2

D = 0,5
0,2
0,1
0,05
0,02
0,01
0,005
0

10 1

10 0

10 -1 -7
10

10

-6

10

-5

10

-4

10

-3

D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5

10 1

10

-2

10

10 0 -6
10

10

-5

10

-4

10

-3

10

-2

TP

10

10

TP

Permissible Puls Load RthJS = (tp)

Permissible Pulse Load

BAV99S

IFmax / I FDC = (t p)
BAV99S
10 2

10 3

IFmax/ IFDC

RthJS

K/W

10 2

D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5

10 1

0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0

10 1

10 0 -6
10

10

-5

10

-4

10

-3

10

-2

10

10 0 -6
10

tp

10

-5

10

-4

10

-3

10

-2

tp

Mar-10-2004

BAV99...
Permissible Puls Load RthJS = (tp)

Permissible Pulse Load

BAV99T

IFmax / I FDC = (t p)
BAV99T

10

10 2

I Fmax/ IFDC

RthJS

KW

10 2

10

10

D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0

10 0 -6
10

D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5

10

-5

10

-4

10

-3

10

-2

10

10 0 -6
10

10

-5

10

-4

10

-3

10

-2

tp

10

10

tp

Permissible Puls Load RthJS = (tp)

Permissible Pulse Load

BAV99U

IFmax / I FDC = (t p)
BAV99U
10 2

10 3

IFmax/ IFDC

RthJS

K/W

10 2

D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5

10 1

D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0

10 1

10 0 -6
10

10

-5

10

-4

10

-3

10

-2

10

10 0 -6
10

tp

10

-5

10

-4

10

-3

10

-2

tp

Mar-10-2004

BAV99...
Permissible Puls Load RthJS = (tp)

Permissible Pulse Load

BAV99W

IFmax / I FDC = (t p)
BAV99W

10

10 2

I Fmax/ I FDC

R thJS

K/W

10 2

D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5

10 1

0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0

10 1

10 0 -6
10

10

-5

10

-4

10

-3

10

-2

10

10 0 -6
10

tp

10

-5

10

-4

10

-3

10

-2

10

tp

Mar-10-2004

This datasheet has been download from:


www.datasheetcatalog.com
Datasheets for electronics components.

Вам также может понравиться