Вы находитесь на странице: 1из 4

DESIGN OF DEGASER

Client name :- CELARWATER


INPUT

LIQUID- Water
Date:- 19/06/12
D. TEMP (C)

50

Daimeter (m)
Height (m)
(L/D)
K2 value
K design factor

1.5
Volume (m3)
4
Density (kg/m3)
2.666666667
1.2 For PP put 1.2 else Range is 1.2 -2
9.801

Ul CSM (n/mm per kg/m2 glass)

20.40608101

Ul WR

30.60912

28

Us WR

32

Us CSM (n/mm per kg/m2 glass)


% CSM sterss

0.145757722

UL CSM (n/mm per kg/m2 glass)


UL WR (n/mm per kg/m2 glass)

20.40608101
23.32123544

P (n/mm2)
Q (n/mm)
put no of layers
N eq
CSM thickness (mm)
WR thickness (mm)
Total shell Thickness (mm)
Area of Shell
Area of bottom
Area of cover
Area of knucle
total area
CSM wt in(kg)
WR wt in (kg)
Shell stiffner CSM
Top stiffners CSM

% WR stress

7.065
1000

0.191307

0.043164
32.373
1
50.72368709 > Q check
3.96
0.66
4.62
18.84
2.8296
2.8296
2.826
30.1512
54.27216
18.09072
0
0

CSM wt (kg)
R wt (kg)

54.27216
135.6804

WR wt (kg)
R wt (kg)

18.09072
21.708864

0.6 knucle 0.4 mfor small t & 0.6 m For big

0 no of stiffners
0

C. B layer area for frvs

For FRVS CSM in (kg)


FRVS resin (kg)

0
0

C. B layer area for PP

24.499

24.4992 PUT FOR FRVS LAYER

24.4992 PUT FOR PP LAYER

COSTING
DESCRIPTION
CSM
WR
R
FRVS
PP
M.C.
P&L
NOZZLE & MANHOLE
NUT BOLT & GASKET
LADDER
MOLD
lugs and hook

QTY /RATE
PER
54.27216
18.09072
157.389264
0
24.499

TOTAL
120
95
135
230
430

0.95
15000
10000
10000
10000
0

6512.6592
1718.6184
21247.55064
0
10534.57
0
40013.39824
38012.72833

45000

GRAND TOTAL

empty vessle wt (kg)


liqid wt (kg)
total (wt)

123026.1266

229.752144 0.229752
7065
7.065
7.294752

DEGASER ASSEMBLY
DIMISTER PAD
HOLDING TANK
vol reqired (m3)

PPACKINGS

PP MADE 1250MM DAI 150 MM HEIGHT


10 min Residance time
80 flowrater (m3/hr)
13.33333333

SIZE & MOC


Packing height (m)
Packing volume
no of packing / m3
no of packing
no of packing /kg
kg of packing

3" PP

PUMP

80 M3 /HR

BLOWER

4000 M3/HR

3
5.29875
2360
12505.05
34
367.7955882

OUTLET

PUMP

COSTING
DISCRIPTION
DIMISTER PAD
HOLDING TANK
PACKING
PUMP
BLOWER
INLET DUCT
OUTLET DUCT
PIPING & DISRUBUTION

FINAL TOTAL OF SYSTEM

RATE
20000
185000
91948.89706
0
100000
10000
5000
15000
0
0
426948.8971

250 PUT RATE/KG

549975.0236

4m

1.5 m

Вам также может понравиться