CALC'N REFERENCE NO.

: 2012018-4-M
DATASHEET REFERENCE
: 08357-DS-7604-MV-1005
DESIGN CODES
: ASME V111 Div.1,2010, 2011a/AS1210-2010
PROJECT SPECIFICATION
: ED-1-1158-4-0101
============================================================================================
DESIGN DATA SUMMARY
============================================================================================
ITEM No.
= 1176 V 1005
DESCRIPTION
= PRIMARY AIR FILTER
DIMENSION
= 1810mm ID - 2130mm LENGTH (TL/TL)
POSITION
= VERTICAL
SOFTWARE USED FOR CALCULATION
= PV ELITE 2012
============================================================================================
DESIGN CRITERIA
============================================================================================
NAME OF FLUID
= AIR
DESIGN PRESSURE
= 810
kPa(g)
VACUUM CONDITION
= kPa(g)
OPERATING PRESSURE
= 665
kPa(g)
DESIGN TEMPERATURE (Min./Max.)
= 2/264
deg C
MDMT
= 2.0
deg C
CORROSION ALLOWANCE,CA
= 0
mm
JOINT EFFICIENCY(SHELL/HEAD)
= 0,85/1
SELECTED fh/f (lowest)
HYDROSTATIC TEST PRESSURE:
1.43 * D.P * fh/f

1158.3

RADIOGRAPHY
POST WELD HEAT TREATMENT
HARDNESS TESTING
IMPACT TESTING
IMPACT TESTING TEMPERATURE
FLANGE CLASS & TYPE USED

=
=
=
=
=
=

SPOT
NO
NO
NO
N/A
deg C
CLASS 150 & B16.5 RFWN

MATERIAL:
SHELL & HEAD
NOZZLE (PIPE/PLATE)
FLANGE/FORGING
FITTING
SUPPORT/EXT.ATTACHMENT
STUD BOLT/NUTS

=
=
=
=
=
=

SA
SA
SA
SA
SA
SA

kPa(g)

240M 304L
312M TP304L/SA 240M 304L
182 F304L
403M WP304L
240M 304L
193M B8 CL.2/SA 194M 8

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

NOTE :
1) fh= allowable stress @ hydrotest temperature, f= allowable stress @ design temperature

============================================================================================