Вы находитесь на странице: 1из 5

Multi-band Panel Dual Polarization Half-power Beam Width Adjust.

Electrical Downtilt Enhanced Sidelobe Suppression

1710 2690 X 65 0 12 18dB

1710 2690 X 65 0 12 18dB

Downtilt set by hand or by optional RCU (Remote Control Unit)


XXPol Panel 17102690/17102690 65/65 18/18dBi 012/012T ESLS
Type No. Frequency range 1710 1990 MHz Polarization Gain (dBi) Tilt Horizontal Pattern: Half-power beam width Front-to-back ratio (180 30) Cross polar ratio Sector Vertical Pattern: Half-power beam width Electrical tilt Sidelobe suppression for first sidelobe above main beam Impedance VSWR Isolation, between ports Intermodulation IM3 Max. power per input 0 ... 6 ... 12 T 18 ... 18 ... 18 dB 7.1 6.5 0 ... 6 ... 12 T 18 ... 18 ... 18 dB 50 < 1.5 > 30 dB < 150 dBc (2 x 43 dBm carrier) 300 W (at 50 C ambient temperature) 5.9 0 ... 6 ... 12 T 18 ... 17 ... 17 dB 5.7 0 ... 6 ... 12 T 18 ... 18 ... 17 dB 0 12, continuously adjustable 0 60 65 > 25 dB, avg. 28 dB Typically: 30 dB > 10 dB 65 > 26 dB, avg. 28 dB Typically: 30 dB > 10 dB 61 > 25 dB, avg. 27 dB Typically: 25 dB > 8 dB 61 > 25 dB, avg. 27 dB Typically: 25 dB > 10 dB +45, 45 17.4 ... 17.4 ... 17.3 0 ... 6 ... 12

80010622
17102690 1920 2200 MHz 2200 2490 MHz +45, 45 17.8 ... 17.6 ... 17.5 0 ... 6 ... 12 +45, 45 18.0 ... 17.9 ... 17.5 0 ... 6 ... 12 2490 2690 MHz +45, 45 18.0 ... 17.7 ... 17.3 0 ... 6 ... 12

1710 1990 MHz: +45/ 45 Polarization


125 65 7.1

10 3 0

10

dB

3 0

Horizontal Pattern

Vertical Pattern 0 12 electrical downtilt

dB

1710 2690 +45

1710 2690 45

1710 2690 +45

1710 2690 45

7-16

7-16

7-16

7-16

1920 2200 MHz: +45/ 45 Polarization


Mechanical specifications
125 65

Input
6.5

4 x 7-16 female Bottom 2 x, Position bottom continuously adjustable Frontal: Lateral: Rearside: 720 N (at 150 km/h) 165 N (at 150 km/h) 740 N (at 150 km/h) 200 km/h 1415 / 323 / 71 mm M (Medium) 17.5 kg / 19.5 kg (clamps incl.) 1706 x 337 x 112 mm Panel and 2 units of clamps for 50 115 mm diameter

Subject to alteration.

Connector position Adjustment mechanism Wind load

10 3 0

10

dB

3 0

Horizontal Pattern

Vertical Pattern 0 12 electrical downtilt

dB

2490 2690 MHz: +45/ 45 Polarization


110 61 5.7

Max. wind velocity Height/width/depth Category of mounting hardware Weight Packing size Scope of supply

936.3621/a

10 3 0

10

dB

3 0

Horizontal Pattern Internet: www.kathrein.de

Vertical Pattern 0 12 electrical downtilt

dB

80010622 Page 1 of 5

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

Accessories General Information


Accessories
20 Type No. 738546 85010002 85010003 737978 Description 1 clamp 1 clamp 1 clamp Remarks Mast: 50 115 mm diameter Mast: 110 220 mm diameter Mast: 210 380 mm diameter Weight approx. 1.0 kg 2.7 kg 4.8 kg 2.8 kg Units per antenna 2 (included in the scope of supply) 2 (order separately if required) 2 (order separately if required) 1 (order separately if required) 72 64 9 254 48 41 71 98 323 Bottom view 45 45 RCU +45 +45 17102690 Left Right 17102690 RCU Layout of interface Please note: The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues have now become invalid. Page 2 of 5 80010622
Internet: www.kathrein.de

1 downtilt kit Downtilt angle: 0 15

For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. Material: Reflector screen: Tin-plated copper. Radiator: Tin-plated zinc. Flat fiberglass radome: The max. radome depth is only 71 mm. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The colour of the radome is grey. All screws and nuts: Stainless steel. The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. 1415 1480 1520 Adjustment mechanism with integrated scale 30
936.3621/a Subject to alteration.

Grounding:

Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with regard to the following items: Low temperature: 55 C High temperature (dry): +60 C Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions. Environmental tests: Kathrein antennas have passed environmental tests as recommended in ETS 300 019-2-4. The homogenous design of Kathreins antenna families use identical modules and materials. Extensive tests have been performed on typical samples and modules.

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions.

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

Mounting Hardware Clamp included in the scope of supply

Suitable for mast diameter Antenna mast distance F Number of pieces Material of clamp and screws Weight

50 115 mm 18 26 mm 1 clamp Hot-dip galvanized steel / stainless steel 1.0 kg

Torque MA = G

Torque: M8 => MA = 20 Nm M6 => MA = 8 Nm

A 152 mm

B 40 mm

C 40 mm

D 50 115 mm

E 93 mm

F 18 26 mm

G 20 Nm

H 125 mm

Washer

936.3621/a

Subject to alteration.

Internet: www.kathrein.de

80010622 Page 3 of 5

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

General Instructions for Adjustment Mechanism

Description of the adjustment mechanism (protective cap removed):

2 2

Adjustment wheel with twist-lock function. Downtilt spindle with integrated scale.

Thread for fixing the protective cap or the RCU (Remote Control Unit). Gearwheel for RCU power drive.

To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment.

Manual adjustment procedure:

0 max.

max. 0

Remove the protective cap.

Set downtilt angle by rotating the adjustment wheel.

Screw on the protective cap again.

Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:


Subject to alteration.

For a description of RCU installation please refer to the respective data sheet.
Page 4 of 5 80010622
Internet: www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

936.3621/a

General Instructions for Feederline Installation on Panels with four Connectors arranged on two Levels
Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.

Description of connector arrangement:

There are four interfaces for feeding the antenna located at the bottom.

The connectors are mounted at two levels in order to facilitate feederline installation.

Attachment of the feederline connector and RCU (optional):


In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation!

Start with the rearside located interface no. 1. Place the connector carefully and fix the nut using a torque-wrench (according to the manufacturers guidelines). The further sequence for the installation is: feederlines no. 2, 3, 4.

After feederline installation the optional remote control units (RCU) can be mounted if required.

For a full description of RCU installation please refer to the respective data sheet.

936.3621/a

Subject to alteration.

Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required, nor is it recommended by the connector manufacturers.
80010622 Page 5 of 5

Internet: www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

Вам также может понравиться