Objective: Distillate should have below C9 components and should not contain C10 and higher components Defining Variables: Variable Name DISTIL C9 C10 Description Mole Flow rate of Distillate Mole Flow rate of C9 in Distillate Mole Flow rate of C10 in Distillate Units kmol/hr kmol/hr kmol/hr
Aim: To ensure more than 95% of C9 and less than 5% C10 of feed goes to Distillate Tolerance of 5% 95% of C9 in Feed 5% of C10 in Feed 13.66 0.82
To Vary: DISTIL from 0.015 kmol/hr to 0.025 kmol/hr in 10 steps Results of Senstivity Analysis as exported from Aspen Plus VARY 1 STRIPPER COL-SPEC MOLE-D KMOL/HR 1 2 3 4 5 6 7 8 9 10 11 15.00 16.11 17.22 18.33 19.44 20.33 20.56 21.67 22.78 23.89 25.00 Result: Run 6 & Run 7 Satisfy our Criteria
Run
C10 KMOL/HR 0.08 0.10 0.13 0.18 0.30 0.59 0.73 1.59 2.60 3.65 4.71
C9 KMOL/HR 8.99 10.07 11.15 12.21 13.20 13.79 13.89 14.13 14.22 14.27 14.30
Aim: To ensure more than 95% of C9 and less than 5% C10 of feed goes to Distillate Tolerance of 5% 95% of C9 in Feed 5% of C10 in Feed To Vary: STAGE from 20 to 50 in steps of 5 Run 1 2 3 4 5 6 7 VARY STRIPPER STAGE 20 25 30 35 40 45 50 C10 KMOL/HR 2.0607 1.3325 0.9588 0.5926 0.4151 0.2564 0.1774 C9 KMOL/HR 12.2011 13.0253 13.4204 13.7897 13.9681 14.1269 14.2059 13.66 0.82