AS 4250.

4—1995

Australian Standard
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

Liquid hydrocarbons—Dynamic
measurement—Proving systems
for volumetric meters

Part 4: Temperature corrections


in volumetric calibration by water
transfer method
This Australian Standard was prepared by Committee ME/49, Oil and Gas
Measurement. It was approved on behalf of the Council of Standards Australia on
30 November 1994 and published on 5 April 1995.

The following interests are represented on Committee ME/49:


Australian Customs Service
Australian Gas Association
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

Australian Institute of Petroleum


Australian Institute of Physics
Australian Liquefied Petroleum Gas Association
Australian Petroleum Exploration Association
CSIRO, Division of Applied Physics
Department of Primary Industries and Energy
Institute of Instrumentation and Control, Australia
Institution of Engineers, Australia
National Association of Testing Authorities
National Standards Commission
The Pipeline Authority

Review of Australian Standards. To keep abreast of progress in industry, Australian Standards are subject
to periodic review and are kept up to date by the issue of amendments or new edit ions as necessary. It is
important therefore that Standards users ensure that they are in possession of the latest edit ion, and any
amendments thereto.
Full detail s of all Australi an Standards and related publications will be found in the Standards Australi a
Catalogue of Publications; this information is supplemented each month by the magazine ‘The Australi an
Standard’, which subscribing members receive, and which gives details of new publications, new editi ons
and amendments, and of withdrawn Standards.
Suggesti ons for improvements to Australian Standards, addressed to the head off ice of Standards Australia,
are welcomed. Notif ication of any inaccuracy or ambiguit y found in an Australi an Standard should be made
without delay in order that the matter may be investigated and appropriate action taken.

This Standard was issued in draft form for comment as DR 93327.


AS 4250.4—1995

Australian Standard
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

Liquid hydrocarbons—Dynamic
measurement—Proving systems
for volumetric meters

Part 4: Temperature corrections


in volumetric calibration by water
transfer method

First publi shed as AS 4250.4—1995.

PUBLISHED BY STANDARDS AUSTRALIA


(STANDARDS ASSOCIATION OF AUSTRALIA)
1 THE CRESCENT, HOMEBUSH, NSW 2140
ISBN 0 7262 9540 X
AS 4250.4 — 1995 2

PREFACE

This Standard was prepared by the Standards Australia Committee on Oil and Gas
Measurement. It is Part 4 of a series of Standards dealing with petroleum liquid measurement
systems.
Other Standards or proposed Standards in this series are as follows:

Part 1: General principles


Part 2: Pipe provers
Part 3: Pulse interpolation
Part 5: Dynamic measurement
The objective of this Standard is to provide those involved in determining the volume of a
vessel used for measuring petroleum liquid with a method of calculating the volume
corrections for temperature required for calibration by the water transfer method.
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

The term ‘informative’ has been used in this Standard to define the application of the
appendix to which it applies. An ‘informative’ appendix is only for information and guidance.

 Copyri ght STANDARDS AUSTRALIA


Users of Standards are reminded that copyri ght subsists in all Standards Austr alia publi cati ons and software. Except where the
Copyri ght Act all ows and except where provided for below no publications or software produced by Standards Australi a may be
reproduced, stored in a retr ieval system in any form or transmitt ed by any means without prior permission in writ ing from
Standards Australi a. Permission may be conditi onal on an appropriate royalt y payment. Requests for permission and information on
commercial soft ware royalti es should be dir ected to the head off ice of Standards Australi a.
Standards Austr alia will permit up to 10 percent of the technical content pages of a Standard to be copied for use exclusively
in-house by purchasers of the Standard wit hout payment of a royalty or advice to Standards Austr alia.
Standards Austr alia wil l also permit the inclusion of its copyright material in computer soft ware programs for no royalt y
payment provided such programs are used exclusively in-house by the creators of the programs.
Care should be taken to ensure that materi al used is from the current editi on of the Standard and that it is updated whenever the
Standard is amended or revised. The number and date of the Standard should therefore be clearly identif ied.
The use of materi al in print form or in computer software programs to be used commercially, with or without payment, or in
commercial contracts is subject to the payment of a royalty. This policy may be vari ed by Standards Austr alia at any ti me.
3 AS 4250.4 — 1995

CONTENTS
Page

1 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . .. .. .. .. ... ........ ... 4


2 APPLICATION . . . . . . . . . . . . . . . . . . . . . . .. . .... .. ... ... .. ..... ... 4
3 REFERENCED DOCUMENTS . . . . . . . . . . . .. ..... ..... ..... ... .. .. . 4
4 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . .. ... ... .. .. .. .. ... ... ... 4
5 NOTATION . . . . . . . . . . . . . . . . . . . . . . . . .. . ... .. .. .. .. ... ..... ... 5
6 TEMPERATURES . . . . . . . . . . . . . . . . . . . .. ...... ... .. .. .. .. ... ... 5
7 CUBIC EXPANSION COEFFICIENTS . . . . . .. .. .. ... ............. ... 6
8 CALCULATIONS . . . . . . . . . . . . . . . . . . . . .. .... .... .. .. .. .. .... ... 6
9 ROUNDING OF NUMBERS . . . . . . . . . . . . .. ............. ... .. .. .. . 8
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

APPENDICES
A FLOW CHART FOR DETERMINING TEMPERATURE CORRECTION BY
ON-SITE COLLECTION OF DATA FOR LATER CALCULATION . . . . . . . 9
B FLOW CHART FOR DETERMINING VOLUME CORRECTION
BY SIMULTANEOUS CALCULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
C EXAMPLES OF CALCULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AS 4250.4 — 1995 4

STANDARDS AUSTRALIA

Australian Standard
Liquid hydrocarbons—Dynamic measurement—
Proving systems for volumetric meters

Part 4: Temperature corrections in volumetric calibration


by water transfer method

1 SCOPE This Standard specifies the corrections necessary to allow for changes in
volume due to differences in temperature between the water in a reference measure and that
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

in the vessel, and to allow for the differences between these temperatures and the reference
temperatures, when determining or checking the volume of a vessel.
This Standard does not set out a calibration procedure nor consider the uncertainties in
temperature measurement, for which reference should be made to other relevant Standards.

2 APPLICATION This Standard is applicable to any industry in which the determination


of the volume of a vessel, or the calibration of a tank or other container, is carried out by
transfer of water from or to a reference measure.
In particular, this Standard is intended for use in the calibration of a meter proving tank when
a reference measure is used to transfer water to, or from, a vessel.
Unless otherwise specified in the calibration procedure, the corrections apply for water
temperatures in the range 5°C to 40°C, but with a difference of not more than 5°C between
the water temperatures in the measure and in the vessel being calibrated.
The calculation procedure is accurate for water temperatures within the range 5°C to 40°C,
but the maximum difference of 5°C is specified between the temperatures in the measure and
in the tank in order to avoid other errors that could arise if the difference were greater, e.g.
water temperature gradients within the vessel being calibrated could lead to errors in the
determination of temperature.

3 REFERENCED DOCUMENTS The following documents are referred to in this


Standard:
AS
2649 Petroleum liquids and gases —Measurement — Standard reference conditions
2706 Numerical values —Rounding and interpretation of limiting values
2849 Density of water —Numerical value

4 DEFINITIONS For the purpose of this Standard, the definitions below apply.
4.1 Measure — a reference volume standard traceable to Australian National Standards.
4.2 Shall — indicates that a statement is mandatory.
4.3 Should — indicates a recommendation.
4.4 Tank (or prover) —a volumetric vessel to be calibrated.
4.5 Volumetric correction — the true volume of a vessel minus the indicated
volume (see Clause 8.6).

COPYRIGHT
This is a free preview. Purchase the entire publication at the link below:

AS 4250.4-1995, Liquid hydrocarbons - Dynamic


measurement - Proving systems for volumetric
meters Temperature corrections in volumetric
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.

calibration by water transfer method

Looking for additional Standards? Visit SAI Global Infostore


Subscribe to our Free Newsletters about Australian Standards® in Legislation; ISO, IEC, BSI and more
Do you need to Manage Standards Collections Online?
Learn about LexConnect, All Jurisdictions, Standards referenced in Australian legislation
Do you want to know when a Standard has changed?
Want to become an SAI Global Standards Sales Affiliate?

Learn about other SAI Global Services:

LOGICOM Military Parts and Supplier Database


Metals Infobase Database of Metal Grades, Standards and Manufacturers
Materials Infobase Database of Materials, Standards and Suppliers
Database of European Law, CELEX and Court Decisions

Need to speak with a Customer Service Representative - Contact Us

Вам также может понравиться