213.00
61066.04
42947.21
38081.04
942.00
54385.66
53005.00
52792.98
Contractor
) )
13.29 Providing and laying vibrated cement concrete M15 Proportionusing hard, granite or trap or Cum basalt jelly 20 mm and down size including mixing with machine mixer, laying vibrating, curing and smooth finishing to exposed faces with cement morter 1:3 proportion with necessary shoring, strutting, formwork including bailing out water with all lead and all lifts etc., complete as per specification for well steining.and as directed by the Engineer-incharge. 3.00 Providing and installing at site of work 90mm dia 6 KSC PVC Pipe including cost of pipe Rmt and specials and labour including lowering in to trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour and lift charges, handling charges with an initial lead of 5 Km including encasing the pipe all round to a depth not less than 15 cm with gravel or selected earth available from the excavation etc., complete.and as directed by the Engineer-in-charge. 10.37 Providing and filling with boulders or ruble of approved size and quality, including Cum hand packing, wedging, filling in voids with quarry spalls and clean sand etc.,complete with all leads and with all lifts.and as directed by the Engineer-in-charge. 1.01 Providing and laying granite or trap or basalt jelly cement concrete 40 mm CC M10 and Cum down size jelly for foundation laid in 15 cm thick layers and well compacted including machine mixing, curing etc., complete as per specification.and as directed by the Engineerin-charge. 4.90 Providing and laying granite or trap or basalt jelly cement concrete M10 proportion using 20 Cum mm and down size jelly including machine mixing, laying, tamping, curing and plastering for exposed faces with cement mortar 1:4 proportion and with necessary centering, form work etc., complete.and as directed by the Engineer-in-charge.
109602.63
489.00
779.00
8078.23
10
3292.00
Rupees: Three thousand two hundred ninty two only Rupees: Three thousand one hundred thirty two only
3324.92
11
3260.00
15974.00
Contractor
) )
12
1.00 Rcc Hume pipe circular pump house manufacturing and supplying precast spun Rcc conical roof as per specifications and drawings. The Rcc Hume pipe pump house should have in internal diameter of 1200 mm and a height of 2.5 m with wall thickness of 65 mm. the Rcc Hume pipe pump house should consists of 12 rods or 6 mm dia bound at 50 mm pitch (CC) with 2 extra turns at both ends. the reinforcement should be placed in the wall giving adequate cover for concrete at both sides throughout its length. The cement concrete should have cemen content of 360 Kg per cum of concrete. the concrete should be compacted at adequate speed such that resultant conceret is dense and homogenous. The door frame should be ISA 35 x 35 x 5 mm welded to the reinforcement cage. The doors size should be of 600 mm width and 1800 mm height. The shutter should be of 18 gauge MS sheet welded on a frame of ISA 25 x 25 x 150 mm at top of the shutter for ventilation purpose. Th e opening is to be of a frame ISA mesh as shown in drawing. The doors should be painted on either side with 2 coats of anti-corrosive paints with a primer coat of red-oxide paint. The roof is to be made of precast Rcc. slab of 1600 mm diameter rods and 50 mm thick. The reinforcement should be of 6 mm dia adequate cover at the top and bottom sides. The concrete should have a cement content of 400 Kg per cum of concrete be of soils 12 mm and below and good river sand should be used, finished smooth both sides. and as directed by the Engineer-in-charge. 1200.00 Providing and installing at site of work 110 mm dia 6KSC PVC Pipe including cost of pipe and specials and labour including lowering in to trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour and lift charges, handling charges with an initial lead of 5 Km including encasing the pipe all round to a depth not less than 15 cm with gravel or selected earth available from the excavation etc., complete.and as directed by the Engineer-in-charge.
Nos
12911.00
13
Rmt
228.00
273600.00
14
432.00 Refilling the basement and pipeline trenches with selected available earth from trench Cum excavation including watering, consolidation in layers of 15 cms thick including disposing of the surplas earth with a lead of 200 mtrs.and as directed by the Engineer-in-charge. 1.00 Supply and delivery at site 10 HP 80 x 50 size and 34.50 meter head with a discharge of 840 LPM suitable centrifugal pump confirming to latest IS standards as directed by the Engineer-in-charge. Nos
63.00
27216.00
15
33950.00
33950.00
Contractor
) )
16 17 18 19
1.00 Supply and delivery at site 10 HP starter suitable for centrifugal pump confirming to latest IS standards as directed by the Engineer-in-charge. 1.00 VI Earthing system confirming to IS 3049/1968 and as directed by the Engineer-in-charge. 20.00 Supplying and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets .as directed by the Engineer-in-charge. 1 Indoor type board Consists of 2 Units Meter Board unit and Panel board unit a) Meter board unit : One number MS box of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal scalable door and arrangements for mounting CTs (if any) to connect 3 PH/4 wire energy metre cable box etc., complete A transparent glass pieces should be provided for the protection where the energy meter reading could be read out. b) Panel Board unit : One number cubical type of control panel board of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal to operate on 3 PH/4 wire 50 Hz/400/440 volts AC supply. i) One number brand new best make flush type motor control switch as per IS:6875 with latest ammendments b) 6 to 35 Hp - 30 Amphs ii) One number of brand new best make voltameter of range 0.600/volts as per IS 1248 witrh latest ammendments iii) One number of brand new best make single phase preventer as per IS 3231 with latest ammendments. iv) One number of brand new best make ammeter as per IS 1248 with latest ammendments. v) Indicator lamps for visual indication of electrical power as per IS:9224-1979 with latest ammendements vi) One number of 30Amps DP switch of brand new best make as per IS:9224-1979 with latest ammendments vii) Earthing : The box shall be provided with plate bolt and nuts viii) Rewieable fuse units :
12500.00 Rupees: Twevel thousand five hundred only 1500.00 Rupees: One thousand five hungred only 215.00 Rupees: Two hundred fifteen only 11180.00 Rupees: Eleven thousand one hundred eighty only
Contractor
) )
0.00 b) 6 to 35 Hp - 30 Amphs ix) Danger board: Danger board confirming to KEB standards should be provided on the panel These 2 units (A & B) complete shall be mounted on extra sheet metal of 20mm thick and screwed on to the box with specified above proper space in between. This complete unit shall be mounted on the MS angle of size 65x65x8mm fabricated pedestal and epoxy painted with rust resistant primer and two coats of ash grey/olive green paints. these two units specified above with proper space in between the shall be provided and rubber bushed retained in position so that they could be used as and when required complete panel writing should be done with cable as per IS: 694/1990 with its latest amendments.Complete unit comprising of all the above items with one number best make brand new push button operated starter as per IS: 5124 and its latest ammendments with protective relay. b) 6-10 Hp and as directed by the Engineer-in-charge. 20 12.00 Supply and delivery at site 100 mm dia 14.70 Kg/m heavy duty GI pipes as per IS 1239 (Part-I) 1973 and 1239 (Part-II) 1968 threaded ends 2.00 Supply and delivery at site wrought mild steel fitting (galvanized) 100 mm dia bends confirming to IS 1239-11/ 91 with latest amendments if any 12.00 Laying and jointing 100 mm dia GI pipe without earthwork including aligning to line slope, fixing collars, elbows, bends, gland cocks and other fittings with cuts and threads wherever necessary, conveying the materials from stores to the workspot and returning surplus materials from workspot to stores with all lead (excluding cost of pipe and specials) Total Rmt 998.58 Rupees: Nine hundred ninty eight & fifty eight paisa only 323.00 Rupees: Three hundred twenty three only 39.00 Rupees: Thirty nine only 11982.96
21 22
Nos Rmt
646.00 468.00
815831.60
1 I/We hereby under take to execute the above at _______________________ % ABOVE the estimate rates. 2 I/We hereby under take to execute the above at _______________________ % LESS the estimate rates. 3 I/We hereby under take to execute the above at estimate rates. Note: 1) Please strikeout which over is not applicable 2) Each correction and over writing shall have signed by the contractor.
Contractor
) )
Executive Engineer KBJNL, MBC O& M Divn. Chigarahalli Executive Engineer . KBJNL,MBC O&M Division Chigarahalli .
Contractor
) )
PART 'A' 11 KV LINE Extension Sl No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Particulars RCC Pole 9 mtr long RCC Pole 8 mtr long PSC Pole 8 mtr long PCC Pole 8 mtr long 11 KV Horizontal Cross Arm with HT Single top support clamps, bolts, nuts and washers 11 KV Pin Insulators with GI Pin 45 KN Disc Insulator Guy sets complete q Rabbit ACSR Conductor with 1.5 % Sag Conductor Accessories at 3 % Spiral Earth Electrodes road guarding DP set Miscellaneous materials LABOUR CHARGES Erection of 9 mtr Pole Erection of 8 mtr Pole Fixing of Cross Arms Fixing Guy set Fixing of Spiral Earth Electrodes Fixing of road guarding Erection of DP set Stringing of conductor Misc. Labour charges Casual labour charges Contigencies @ 3 % on above EPF Charges @ 25.61 % on LC Service tax @ 10.34 % on LC Electrical Inspectorate Charges Loadinf & Unloading of RCC poles Loadinf & Unloading of PCC poles Unit Nos. Nos. Nos. Set Set Nos. Nos. Set Km Set /Span Set L/S TOTAL Nos. Nos. Set Set Set Set Set Km L/S Qty Rate Amount 4241.00 10 3011.00 30110.00 2214.00 1871.00 11 335.00 30 72.00 3 275.00 4 645.00 1.339 20240.00 10 190.00 1350.00 10942.00 3685.00 2160.00 825.00 2580.00 27101.00 813.00 1900.00
25.60 69199.60 466.00 373.00 44.00 156.00 24.00 466.00 1098.00 1147.00 Total
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
10 11 4 10
1.339
10
40/30 25 TOTAL
PART C : PROVIDING 2 POLE STRUCTURE Sl No Description Providing 2 pole structure at the tapping using 8 mtr with labour charges as per cost data 1 sheet No.15 2 EPF Charges @ 25.61 % on Labour Charges 3 Service tax @ 12.36 % on Labour Charges 4 Contigencies @ 3 % on above
Unit
Qty.
Rate
Amount
Sl No. Description Erection of 25/63/100 KVA 3 Phase Transformer with complete set including Labour charges EPF Charges @ 60 % on Labour Charges Service tax @ 10.30% on Labour Charges Contigencies @ 3 % on above Electrical Inspectorate Charges Loading and Unloading of DTC
Unit No
Qty
Rate
Amount
1 2 3 4 5 6
78340
Total
ABSTRACT
Sl No. 1 2 3 4 Description PART A : 11 KV LINE Extension Material PART B : LT Line Extension Material PART C : PROVIDING 2 POLE STRUCTURE PART D : Erection of 25/63/100 KVA DTC Amount 84187.00 20301.00 84362.00 TOTAL 188850.00
Name of work:-Providing irrigation facilities to SC farmers by construction of open well & pump house in Sy.No.18 & 19 of Chigarahalli Village of Jewargi Taluka SCHEDULE "B" RATE
SL NO 1 TOTAL QTY DESCRIPTION OF ITEM UNIT IN FIG IN WORDS AMOUNT 17843.61
20135.22
443.00
18787.63
7576.00
11591.28
53005.00
52050.91
Contractor
) )
13.99 Providing and laying vibrated cement concrete M15 Proportionusing hard, granite or trap or Cum basalt jelly 20 mm and down size including mixing with machine mixer, laying vibrating, curing and smooth finishing to exposed faces with cement morter 1:3 proportion with necessary shoring, strutting, formwork including bailing out water with all lead and all lifts etc., complete as per specification for well steining.and as directed by the Engineer-incharge. 6.00 Providing and installing at site of work 90 mm dia 6 ksc PVC Pipe including cost of pipe Rmt and specials and labour including lowering in to trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour and lift charges, handling charges with an initial lead of 5 Km including encasing the pipe all round to a depth not less than 15 cm with gravel or selected earth available from the excavation etc., complete.and as directed by the Engineer-in-charge. 45.78 Providing and filling with boulders or ruble of approved size and quality, including Cum hand packing, wedging, filling in voids with quarry spalls and clean sand etc.,complete with all leads and with all lifts.and as directed by the Engineer-in-charge. 0.86 Providing and laying granite or trap or basalt jelly cement concrete 40 mm and down size Cum jelly for foundation laid in 15 cm thick layers and well compacted including machine mixing, curing etc., complete as per specification.and as directed by the Engineer-in-charge. 3.74 Providing and laying granite or trap or basalt jelly cement concrete M10 proportion using 20 Cum mm and down size jelly including machine mixing, laying, tamping, curing and plastering for exposed faces with cement mortar 1:4 proportion and with necessary centering, form work etc., complete.and as directed by the Engineer-in-charge.
8322.00
116424.78
170.00
1020.00
943.00
43170.54
3748.00
3223.28
10
15801.50
Contractor
) )
11
1.00 Rcc Hume pipe circular pump house manufacturing and supplying precast spun Rcc conical roof as per specifications and drawings. The Rcc Hume pipe pump house should have in internal diameter of 1200 mm and a height of 2.5 m with wall thickness of 65 mm. the Rcc Hume pipe pump house should consists of 12 rods or 6 mm dia bound at 50 mm pitch (CC) with 2 extra turns at both ends. the reinforcement should be placed in the wall giving adequate cover for concrete at both sides throughout its length. The cement concrete should have cemen content of 360 Kg per cum of concrete. the concrete should be compacted at adequate speed such that resultant conceret is dense and homogenous. The door frame should be ISA 35 x 35 x 5 mm welded to the reinforcement cage. The doors size should be of 600 mm width and 1800 mm height. The shutter should be of 18 gauge MS sheet welded on a frame of ISA 25 x 25 x 150 mm at top of the shutter for ventilation purpose. Th e opening is to be of a frame ISA mesh as shown in drawing. The doors should be painted on either side with 2 coats of anti-corrosive paints with a primer coat of red-oxide paint. The roof is to be made of precast Rcc. slab of 1600 mm diameter rods and 50 mm thick. The reinforcement should be of 6 mm dia adequate cover at the top and bottom sides. The concrete should have a cement content of 400 Kg per cum of concrete be of soils 12 mm and below and good river sand should be used, finished smooth both sides. and as directed by the Engineer-in-charge. 350.00 Providing and installing at site of work 110mm dia6 ksc PVC Pipe including cost of pipe and specials and labour including lowering in to trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour and lift charges, handling charges with an initial lead of 5 Km including encasing the pipe all round to a depth not less than 15 cm with gravel or selected earth available from the excavation etc., complete.and as directed by the Engineer-in-charge.
Nos
12911.00
12
Rmt
82600.00
13
126.00 Refilling the basement and pipeline trenches with selected available earth from trench Cum excavation including watering, consolidation in layers of 15 cms thick including disposing of the surplas earth with a lead of 200 mtrs.and as directed by the Engineer-in-charge. 1.00 CENTRIFUGAL PUMPS AND ACCESSORIES 10 HP Centrifugal Pump 80*50 size 840 lpm and as directed by the Engineer-in-charge. Nos
70.00
8820.00
14
39178.30
39178.30
Contractor
) )
15
16
1.00 Supply and delivery at site the following accessories suitable for monoblock centrifugal pumps of different capacities,rates including. III) Starter Upto 10 HP and as directed by the Engineer-in-charge. 1.00 VI Earthing system confirming to IS 3049/1968 and as directed by the Engineer-in-charge. 20.00 VII LT Cable 4x25 Sq.mm and as directed by the Engineer-in-charge. 1 Indoor type board Consists of 2 Units Meter Board unit and Panel board unit a) Meter board unit : One number MS box of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal scalable door and arrangements for mounting CTs (if any) to connect 3 PH/4 wire energy metre cable box etc., complete A transparent glass pieces should be provided for the protection where the energy meter reading could be read out. b) Panel Board unit : One number cubical type of control panel board of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal to operate on 3 PH/4 wire 50 Hz/400/440 volts AC supply. i) One number brand new best make flush type motor control switch as per IS:6875 with latest ammendments b) 6 to 35 Hp - 30 Amphs ii) One number of brand new best make voltameter of range 0.600/volts as per IS 1248 witrh latest ammendments iii) One number of brand new best make single phase preventer as per IS 3231 with latest ammendments. iv) One number of brand new best make ammeter as per IS 1248 with latest ammendments. v) Indicator lamps for visual indication of electrical power as per IS:9224-1979 with latest ammendements vi) One number of 30Amps DP switch of brand new best make as per IS:9224-1979 with latest ammendments vii) Earthing : The box shall be provided with plate bolt and nuts viii) Rewieable fuse units :
Nos
14425.00 Rupees: Fourty thousand four hundred twenty fiveonly 1731.00 Rupees: One thousand seven hundred thirty one only Rupees: Two hundred twenty only Rupees: Seven thousand nine hundred ninty nine only
14425.00
Nos
1731.00
17 18
Rmt Nos
248.11 11110.00
4962.20 11110.00
Contractor
) )
0.00 b) 6 to 35 Hp - 30 Amphs ix) Danger board: Danger board confirming to KEB standards should be provided on the panel These 2 units (A & B) complete shall be mounted on extra sheet metal of 20mm thick and screwed on to the box with specified above proper space in between. This complete unit shall be mounted on the MS angle of size 65x65x8mm fabricated pedestal and epoxy painted with rust resistant primer and two coats of ash grey/olive green paints. these two units specified above with proper space in between the shall be provided and rubber bushed retained in position so that they could be used as and when required complete panel writing should be done with cable as per IS: 694/1990 with its latest amendments.Complete unit comprising of all the above items with one number best make brand new push button operated starter as per IS: 5124 and its latest ammendments with protective relay. b) 6-10 Hp and as directed by the Engineer-in-charge. 19 12.00 Supply and delivery at site 100 mm dia 14.70 Kg/m heavy duty GI pipes as per IS 1239 (Part- Rmt I) 1973 and 1239 (Part-II) 1968 threaded ends. and as directed by the Engineer-in-charge. 2.00 Supply and delivery at site wrought mild steel fitting (galvanized) 100 mm dia bends Nos confirming to IS 1239-11/ 91 with latest amendments if any. and as directed by the Engineer-in-charge. 12.00 Laying and jointing GI pipes without earthwork including aligning to line slope, fixing Rmt collars, elbows, bends, gland cocks and other fittings with cuts and threads wherever neccessarry conveying the materials from stores to the workspot and returning surplus materials from the workspot to the stores with all leads. 100 mm Dia GI pipes and as directed by the Engineer-in-charge. 1152.36 Rupees: Six hundred seventy only Rupees: Three hundred ninty eight only 13828.32
20
372.74
745.48
21
516.00
Contractor
) )
1 Errection of 3 ph 11000/433 v, 25 KVA, Distn Trans Center as per CDS no3 of 2010-2011 SR Nos. PART-C Extension of LT 3 ph,4 w Set Km
81797.00
1 2
1 RCC Pole 8 mtr long 2 Pin cross arms with clamps bolts and nuts complete set
3196.00 Rupees: Six hundred forty five only 175.00 Rupees: Twenty thousand two hundred forty one only 8.00 Rupees: One hundred ninty only 26.00 Rupees: Three hundred seventy three only
3196.00 350.00
3 4 5 6 7 8
8 8 Kv Strain Insulators 0 1.1 KV Pin Insulators with GI Pin 1 Guy sets complete set 1 Spiral Earth Electrodes 0.2 Weasel ACSR Conductor with 1.5 % Sag 1 Conductor accessaries at 3% on cost of conductor
635.00 Rupees: Fourty four only 204.00 Rupees: One hundred fifty six only 15316.00 Rupees: Twenty four only 91.90 Rupees: One thousand one hundred forty seven only 1400.00 Rupees: Thirty only
Nos.
1400.00
656289.15
1 I/We hereby under take to execute the above at _______________________ % ABOVE the estimate rates. 2 I/We hereby under take to execute the above at _______________________ % LESS the estimate rates. 3 I/We hereby under take to execute the above at estimate rates. Note: 1) Please strikeout which over is not applicable 2) Each correction and over writing shall have signed by the contractor.
Contractor
) )
Name of work:-Providing irrigation facilities to ST farmers by construction of open well & pump house in Sy.No.18 & 19 of Chigarahalli Village of Jewargi Taluka SCHEDULE "B" RATE
SL NO 1 TOTAL QTY DESCRIPTION OF ITEM UNIT IN FIG IN WORDS AMOUNT 125845.78
3748.00
3223.28
15843.75
Contractor
) )
1.00 Rcc Hume pipe circular pump house manufacturing and supplying precast spun Rcc conical roof as per specifications and drawings. The Rcc Hume pipe pump house should have in internal diameter of 1200 mm and a height of 2.5 m with wall thickness of 65 mm. the Rcc Hume pipe pump house should consists of 12 rods or 6 mm dia bound at 50 mm pitch (CC) with 2 extra turns at both ends. the reinforcement should be placed in the wall giving adequate cover for concrete at both sides throughout its length. The cement concrete should have cemen content of 360 Kg per cum of concrete. the concrete should be compacted at adequate speed such that resultant conceret is dense and homogenous. The door frame should be ISA 35 x 35 x 5 mm welded to the reinforcement cage. The doors size should be of 600 mm width and 1800 mm height. The shutter should be of 18 gauge MS sheet welded on a frame of ISA 25 x 25 x 150 mm at top of the shutter for ventilation purpose. Th e opening is to be of a frame ISA mesh as shown in drawing. The doors should be painted on either side with 2 coats of anti-corrosive paints with a primer coat of red-oxide paint. The roof is to be made of precast Rcc. slab of 1600 mm diameter rods and 50 mm thick. The reinforcement should be of 6 mm dia adequate cover at the top and bottom sides. The concrete should have a cement content of 400 Kg per cum of concrete be of soils 12 mm and below and good river sand should be used, finished smooth both sides. and as directed by the Engineer-in-charge. 1600.00 Providing and installing at site of work 110mm dia6 ksc PVC Pipe including cost of pipe and specials and labour including lowering in to trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour and lift charges, handling charges with an initial lead of 5 Km including encasing the pipe all round to a depth not less than 15 cm with gravel or selected earth available from the excavation etc., complete.and as directed by the Engineer-in-charge.
Nos
12911.00
Rmt
377600.00
576.00 Refilling the basement and pipeline trenches with selected available earth from trench Cum excavation including watering, consolidation in layers of 15 cms thick including disposing of the surplas earth with a lead of 200 mtrs.and as directed by the Engineer-in-charge. 1.00 CENTRIFUGAL PUMPS AND ACCESSORIES 10 HP Centrifugal Pump 80*65 size 840 lpm and as directed by the Engineer-in-charge. Nos
70.00
40320.00
39178.30
39178.30
Contractor
) )
1.00 Supply and delivery at site the following accessories suitable for monoblock centrifugal pumps of different capacities,rates including. III) Starter Upto 10 HP and as directed by the Engineer-in-charge. 1.00 VI Earthing system confirming to IS 3049/1968 and as directed by the Engineer-in-charge. 20.00 VII LT Cable 4x25 Sq.mm and as directed by the Engineer-in-charge. 1 Indoor type board Consists of 2 Units Meter Board unit and Panel board unit a) Meter board unit : One number MS box of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal scalable door and arrangements for mounting CTs (if any) to connect 3 PH/4 wire energy metre cable box etc., complete A transparent glass pieces should be provided for the protection where the energy meter reading could be read out. b) Panel Board unit : One number cubical type of control panel board of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal to operate on 3 PH/4 wire 50 Hz/400/440 volts AC supply. i) One number brand new best make flush type motor control switch as per IS:6875 with latest ammendments b) 6 to 35 Hp - 30 Amphs ii) One number of brand new best make voltameter of range 0.600/volts as per IS 1248 witrh latest ammendments iii) One number of brand new best make single phase preventer as per IS 3231 with latest ammendments. iv) One number of brand new best make ammeter as per IS 1248 with latest ammendments. v) Indicator lamps for visual indication of electrical power as per IS:9224-1979 with latest ammendements vi) One number of 30Amps DP switch of brand new best make as per IS:9224-1979 with latest ammendments vii) Earthing : The box shall be provided with plate bolt and nuts viii) Rewieable fuse units :
Nos
14425.00 Rupees: Fourty thousand four hundred twenty fiveonly 1731.00 Rupees: One thousand seven hundred thirty one only Rupees: Two hundred twenty only Rupees: Seven thousand nine hundred ninty nine only
14425.00
Nos
1731.00
10 11
Rmt Nos
248.11 11110.00
4962.20 11110.00
Contractor
) )
0.00 b) 6 to 35 Hp - 30 Amphs ix) Danger board: Danger board confirming to KEB standards should be provided on the panel These 2 units (A & B) complete shall be mounted on extra sheet metal of 20mm thick and screwed on to the box with specified above proper space in between. This complete unit shall be mounted on the MS angle of size 65x65x8mm fabricated pedestal and epoxy painted with rust resistant primer and two coats of ash grey/olive green paints. these two units specified above with proper space in between the shall be provided and rubber bushed retained in position so that they could be used as and when required complete panel writing should be done with cable as per IS: 694/1990 with its latest amendments.Complete unit comprising of all the above items with one number best make brand new push button operated starter as per IS: 5124 and its latest ammendments with protective relay. b) 6-10 Hp and as directed by the Engineer-in-charge. 12 12.00 Supply and delivery at site 100 mm dia 14.70 Kg/m heavy duty GI pipes as per IS 1239 (Part- Rmt I) 1973 and 1239 (Part-II) 1968 threaded ends. and as directed by the Engineer-in-charge. 2.00 Supply and delivery at site wrought mild steel fitting (galvanized) 100 mm dia bends Nos confirming to IS 1239-11/ 91 with latest amendments if any. and as directed by the Engineer-in-charge. 12.00 Laying and jointing GI pipes without earthwork including aligning to line slope, fixing collars, elbows, bends, gland cocks and other fittings with cuts and threads wherever neccessarry conveying the materials from stores to the workspot and returning surplus materials from the workspot to the stores with all leads. 100 mm Dia GI pipes and as directed by the Engineer-in-charge. Rmt 1152.36 Rupees: Six hundred seventy only Rupees: Three hundred ninty eight only 13828.32
13
372.74
745.48
14
516.00
Contractor
) )
1 Errection of 3 ph 11000/433 v, 25 KVA, Distn Trans Center as per CDS no3 of 2010-2011 SR Nos. PART-C Extension of LT 3 ph,4 w Set Km
81797.00
1 2
1 RCC Pole 8 mtr long 2 Pin cross arms with clamps bolts and nuts complete set
3196.00 Rupees: Six hundred forty five only 175.00 Rupees: Twenty thousand two hundred forty one only 8.00 Rupees: One hundred ninty only 26.00 Rupees: Three hundred seventy three only
3196.00 350.00
3 4 5 6 7 8
8 8 Kv Strain Insulators 0 1.1 KV Pin Insulators with GI Pin 1 Guy sets complete set 1 Spiral Earth Electrodes 0.2 Weasel ACSR Conductor with 1.5 % Sag 1 Conductor accessaries at 3% on cost of conductor
635.00 Rupees: Fourty four only 204.00 Rupees: One hundred fifty six only 15316.00 Rupees: Twenty four only 91.90 Rupees: One thousand one hundred forty seven only 1400.00 Rupees: Thirty only
Nos.
1400.00
1004780.21
1 I/We hereby under take to execute the above at _______________________ % ABOVE the estimate rates. 2 I/We hereby under take to execute the above at _______________________ % LESS the estimate rates. 3 I/We hereby under take to execute the above at estimate rates. Note: 1) Please strikeout which over is not applicable 2) Each correction and over writing shall have signed by the contractor.
Contractor
) )