Making sure the survey course and setting down the survey order with NT staff
Surveying on spot
Feeding back to the project leader or the network planner in time,then we make sure .
Making sure the site designing including the transmissionwith NT staff on spot
Making out the site survey report and list Delivering the site drawing to project department ,then begin to construct thesite equipment.
The precision of the GPS must be more than5~8meters ,when we note the longitude and the latitude,so we must wait a while after open the GPS.
General Principles
as close as possible to the planning sitemake for the network optimization later; distance between sites in dense urban area 200300mdeviation should be less than 50 m distance between sites in urban area 400500m deviation should be less than 100 m ; distance between sites in suburban or rural area 8001000m deviation should be less than 200 m . site position choice for early establishment should meet the coverage in hot area, such as highwaymarket or temple ; site position choice in dense urban buildings should avoid the tall buildings or the construction of tall buildings near the antenna
General Principles
Try to avoid large electromagnetic interference, the choice to the electromagnetic environment around the site should avoid radar stations, power stations or high voltage lines (> 30 m); Leasehold BTS room is the primary choicebuilding the roof top towerreducing investment attention to the building load-bearing; With transmission conditions.
Site Equipments
BTS Equipment Configuration
model Site type S444+S666 S444+S444 8018 indoor BTS S666 S444 S222(indoor) 8206 8202 S222(outdoor) O2 Rack Qty. Rack size per 1 rack 2 2 1 1 1 1 1 640x555x330 (mm) 580x400x284 (without base, mm) 1600x600x550(H*W*D mm)
Site Equipments
Power Products Configuration
Site Equipments
Antenna Products Configuration
GSM900M Dual Polarized Directional Antenna MB900-65-17DT/MB900-65-17DT3 (S444: 3 degree electronical Down Tilt) (S222: 0 degree electronical Down Tilt) SIZE:1600280100mm
Site Equipments
Antenna Products Configuration
GSM Dual Band Antenna 16 dBi, 65 degree ODP-065R17B6/18C6 6 degree electronical Down Tilt fixed SIZE:2345320195mm
Site Equipments
Antenna Products Configuration
WCDMA Antenna TypeMB3F-65-18DT2 electronical Down Tilt 2 degree Mechanical Down Tilt >12 degree
Transmission choice
Cable Transmission
Optical fiber transmission
SDH(1663E1N63E1)
PDH(416E1)
DDB
Transmission choice
Cable Transmission
IP transmission G.SHDSL
TC-200GT support DSL line distance of at least 3.3 km(0.4 mm cable) for E1 75 Ohms unbalanced impedance. -48V DC power Front Panel
Rear Panel
Transmission choice
Wireless transmission
Microwave
Antenna &ODU
Antenna &ODU
?
If there is no phone line or the distance of the line is more than 3Km,Microwave must be chosen.
Transmission choice
Wireless transmission
Centrol Room Microwave
sites
Transmission choice
Wireless transmission
Microwave
Microwave Equipment
Microwave Antenna
Site Equipments
Shelter
Shelter Dimension Height(mm) H 3 120 Width(mm) W 2 970 Length(mm) L 4 750 Square(m2) 14.1
Site Equipments
Tower
5m rooftop tower5M.pdf 8m rooftop tower8m.pdf 18m Ground tower18m 20m Ground tower20M
Ground System
Ground System
Site name
inside whole
REC
Battery 300AH/Group II
BTS
The maximal power of BTS B8018 is 3400W ,and the air switch we should select is 63A &32A The maximal power of BTS B8206/B8202 is 380W ,and the air switch we should select is 16A.
the antenna and the poles the outdoor ladder and the Router
Site name
inside whole
window
rooftop
Ground
building