Вы находитесь на странице: 1из 2

Detail Technical description & performance Charactristics SOLID POLYETHYLENE INSULATED FILLED SCREENED POLYETHYLENE SHEATHED ARMOURED CABL

E NAME OF MANUFACTURER : U M Cables Ltd, Silvassa, India MANUFACTURER'S Remarks Sl No. SPECIFICATION PARAMETER UNIT SPEC. VALUE (DESIGNED VALUE) 1 CONDUCTORS a Diameter of the conductor mm Nominal 0.5 b Ultimate elongation of conductor % Min 15% c TS of conductor containing a joint % Min 90% that of conducto r not containing a joint 2 INSULATION a Type of insulation HDPE ( Solid ) b Colour of insulation Easily identifiable under normal lightin g conditions BL , OR , GR , BR , SL , WH, RD c Spark Test (AC) KV 2 3 PAIRING a Lay length mm Max 150mm 4 STRANDING a Unit/Super Unit formation 10 pair unit b Super Unit formation N/A b Colour of Unit Binder Tape BL, OR, GR, BR, SL c Colour of Superunit Binder Tape N/A d Make up of cable 50 Pair : 5 x 10 pair unit 5 CORE FILLING Homogenous, Non toxic & Non dermatic water resis tant compound 6 CORE WRAPPING a Material Non hygroscopic & non-wicking polyester tape app lied longitudinally with a suitable overlap 7 MOISTURE BARRIER a Material Poly-AL. (Longitudinal application) b Overlap mm > 3 c Thickness-Aluminium(nominal) mm 0.2 0.02 8 INNER SHEATH a Material Black LDPE compound free from dirt, moisture and metallic particle b Nominal Thickness mm 2.0 c Average radial thickness of sheath mm 85% of Nominal Thickness d Minimum radial thickness of sheath mm 75% of Nominal Thickness e Spark Test (AC) KV 10 f Minimum Tensile Strength kg/cmsq 70 g Minimum Elongation at Break % 300 h Carbon Black content of sheath % 2.50.5% 9 ARMOUR a Bedding Tape thickness mm Min 0.05 b Steel Tape Thickness mm Nom 0.45 c Steel Tape Gap % 15 % ~ 35% 10 OUTER SHEATH a Material Black LDPE compound free from dirt, moisture and metallic particle b Nominal Thickness mm 1.4 c Average radial thickness of sheath mm 85% of Nominal Thickness

d Minimum radial thickness of sheath mm 75% of Nominal Thickness 8022448181 e Spark Test (AC) KV 10 f Minimum Tensile Strength kg/cmsq 70 g Minimum Elongation at Break % 300 h Carbon Black content of sheath % 2.50.5% i Marking At regular interval of 1 Meter with accuracy of length m easurement within 1% 11 ELECTRICAL PROPERTIES TEST: a Insulation resistance Mohm km 5000 b Electrical resistance of conductors at 20C Ohm/km Max 92.0 c Resistance unbalance % Max Ind.-2.5 Max Avg.-1.0 d Mutual capacitance Max Avg. nF/km 56 e Capacitance unbalance Pair to Pair pF/Km Max Ind.-200 AVG.-50 f Capacitance unbalance Pair to Ground pF/Km Max Ind.-3000 AVG.-750 f Dielectric Strength of insulation between conductors for 3 secs KV 2.4 g Dielectric Strength of insulation between shield and conductors for 3 se cs KV 5 h Packing Length m 1000M i Length Tolerance % +10% / -25% Note : We have considered conductor resistance as significant factor rather tha n conductor diameter We will maintain the conductor diameter accordingly as per the conductor resistance given in Sr No 11 (b)

Вам также может понравиться