Академический Документы
Профессиональный Документы
Культура Документы
Classification: INTERNAL
Deltatop Deltatop
DO62C
DO63C
DO61W
DO64P
DO65F
Classification: INTERNAL
primary type
generation
tapping
mounting
1 flange tap 2 corner tap single bore 3 corner tap annular chamber 4 plate tapping defined via rucksack 5 meter run corner tap / annular chamber 8 orifice solution 9 meter run solution
Classification: INTERNAL
F C W P S
Deltatop Deltatop
Classification: INTERNAL
primary type
profil shape
diamond
Classification: INTERNAL
Deltatop Deltatop
DN63S
Venturi Nozzle
Classification: INTERNAL
Deltatop Deltatop
Classification: INTERNAL
primary type
generation
version
mounting
1 venturi tube
solutions
Classification: INTERNAL
Deltatop Deltatop
DA6xC
DA6xV
DA63M
DA62P
DA63R
Classification: INTERNAL
Pitot Tubes
DP61D DP62D DP63D DP61B DP62B DP62B
av ail ab le
TS
va a
p
b le ila
ion at
pr re
Classification: INTERNAL
DA61C DA61V
ble aila av
DA63M DA63R
Accessories
APS
Advanced Product Structures
Classification: INTERNAL
Order code (max. 60digits) Root (max. 8digits) Must criteria Can criteria
Classification: INTERNAL
DO65F15FBBES..+A1C1C2
Order code for a typical steam application (old) DPO50E-E1C2E4F + DPC50-A1B4 + DPV50-124 + DPM50-1F25
Order code for a typical steam application (new) DO62C50-FBBESC2RAL3AEE2DEBCA2BCDD Order-Ident DO62C50-1082/xxx
Classification: INTERNAL
Guidance by Exclusions
Over 8000 exlusions implemented 8000 little helpers to avoid mistakes Example: Accessory connections
Only things come together which fit to each other
DO63C1F-FB###C1RAT2AVN3CVB
Classification: INTERNAL
Orifices
Classification: INTERNAL
Will be disassembled for welding Welding on site required PED difficult to handle
Deltatop DO61W
Classification: INTERNAL
Deltatop DO62C
Classification: INTERNAL
Deltatop DO63C
Classification: INTERNAL
Deltatop DO64P
Classification: INTERNAL
Deltatop DO65F
Advantages:
Same like DO63C Wet calibration possible Includes straight inlet and outlet run for small diameter step Inlet/outlet pipe compliant to ISO5167 For smallest diameters from DN10
Classification: INTERNAL
Deltatop DO65F
Classification: INTERNAL
Classification: INTERNAL
Pitot Tubes
Classification: INTERNAL
Deltatop DP61D, DP62D, DP63D Pitot Tube with diamond shaped sensor Profile
Classification: INTERNAL
USP
Limitations:
Classification: INTERNAL
Relatively low dp, therefore limited TD Not standardized Relatively high cost for small diameters
Classification: INTERNAL
Classification: INTERNAL
Feature Selection
Process connection Flowtap
Classification: INTERNAL
Feature Selection
Required space for Flowtap
Classification: INTERNAL
Feature Selection
Integrated temperature sensor
Classification: INTERNAL
Accessories
Classification: INTERNAL
Condensate Pots
E+H recommends strongly to use condensate pots in steam applications Condensate pots ensure a stable zero point Condensate pots avoid signal fluctuations
1 1 2 3 4 3 4
Steam enters from process Steam condensates on surface Condensate runs back Stable water level
Classification: INTERNAL
Classification: INTERNAL
Classification: INTERNAL
Classification: INTERNAL
DA63M Manifolds
For all primary elements Included in primary element structure 3-valve and 5-valve manifold For compact and remote versions For high temperature steam application
Classification: INTERNAL
Manifolds
manifold combination
milled milled
Classification: INTERNAL
forged forged
Manifolds
5-valve 5-valve manifold manifold
milled milled
Classification: INTERNAL
Manifolds
forged forged
Classification: INTERNAL
Classification: INTERNAL
Classification: INTERNAL
Classification: INTERNAL
Air