Вы находитесь на странице: 1из 6

HEMPEL

Product Data Sheet

Page 1/2

Product Data
Description: Recommended use: Service temperatures: Availability: PHYSICAL CONSTANTS: Colours/Shade nos: Finish: Volume solids, %: Theoretical spreading rate: Flash point: Specific gravity: Dry to touch: Fully cured: V.O.C.:

HEMPADURSEALER 05990
BASE 05999 with CURING AGENT 95040

HEMPADUR SEALER 05990 is a low viscosity, two pack epoxy varnish with good penetration properties. For saturation of well cleaned concrete surfaces before application of pigmented paints. Must be applied in such an amount that the surface is just saturated. The surface should not appear glossy in any way . Related to substrate and subsequent coat. Part of Group Assortment. Local availability subject to confirmation.

Transparent/00000 Flat 29 1 Not relevant (See REMARKS overleaf) 25C/77F 0.9 kg/litre - 7.5 lbs/US gallon 3-4 hours at 20C/68F 7 days at 20C/68F 610 g/litre - 5.1 lbs/US gallon
The physical constants stated are nominal data according to the HEMPEL Group's approved formulas. They are subject to normal manufacturing tolerances and where stated, being standard deviation according to ISO 3534-1. Further reference is made to "Explanatory Notes" in the HEMPEL Book.

APPLICATION DETAILS: Mixing ratio for 05990: Application method: Thinner (max.vol.): Pot life: Nozzle orifice: Nozzle pressure: Cleaning of tools: Indicated film thickness, dry: Indicated film thickness, wet: Recoat interval, min: Recoat interval, max: Safety:

Base 05999 : Curing agent 95040 4 : 1 by volume Airless spray Brush 08450 (up to 5%) 08450 (up to 5%) 8 hours (20C/68F) .017"-.021" 100 bar/1450 psi (Airless spray data are indicative and subject to adjustment) HEMPELS TOOL CLEANER 99610 Not relevant Not relevant (See REMARKS overleaf) 4 hours (20C/68F) None (See REMARKS overleaf) Handle with care. Before and during use, observe all safety labels on packaging and paint containers, consult HEMPEL Material Safety Data Sheets and follow all local or national safety regulations. Avoid inhalation, avoid contact with skin and eyes, and do not swallow. Take precautions against possible risks of fire or explosions as well as protection of the environment. Apply only in well ventilated areas.

Issued:

September 2002

HEMPEL
HEMPADUR SEALER 05990 SURFACE PREPARATION:

Product Data Sheet

Page 2/2

All possible slip agent, oil, grease and other contaminants must be removed by eg volatilizing by flame cleaning or treatment with suitable detergent. Last mentioned in the following way: Saturation of the surface with fresh water. Washing with detergent followed by fresh water hosing. Depending on construction and purpose, abrasive blast, high pressure water jet or treat the concrete with power tools to obtain a rough and firm surface free of scum layer and other contamination. Remove dust and loose material. If mechanical treatment is impossible, the surface may be treated with acid etching. For this purpose an approx. 5% w/w nitric or phosphoric acid solution is recommended. Note: Strong acids, take necessary precautions, make sure that safety regulations are obeyed! Prior to etching the concrete should be saturated with fresh water to prevent acid corrosion of the reinforcement bars. Leave the acid to act for 3-4 minutes and hose down the surface with fresh water - preferably first a 5% w/w sodium hydroxide solution - and scrub carefully. After that the surface must dry homogeneously and appear as an even, rough surface free of a loose outer layer. The surface must have a pH reaction of between 6.5 - 8.0. If any of these conditions are not fulfilled, the process must be repeated. The surface must be dried with good ventilation for at least 2 days (65% relative humidity and 20C/68F). The pretreatment is controlled by scraping with a strong knife. The surface shall feel solid and hard, and the knife must only leave a clear scratch mark. The concrete must be fully cured, eg 28 days for normal Portland cement, and completely dry with a humidity content in the surface below 4%. The concrete must also be controlled for absence of capillary water action or for subsoil water. Use only where application and curing can proceed at temperatures above 10C/50F. Apply only on a dry surface, free of dust, grease, oil and other contamination - as described above. Strongly absorbing surfaces may need repeated treatment . In any case a glossy surface must not appear and such a surplus of HEMPADUR SEALER 05990 must be removed by sanding , abrasive sweep-blasting or similar methods before painting takes place. In confined spaces provide adequate ventilation during application and drying. According to specification.

APPLICATION CONDITIONS:

SUBSEQUENT COAT: REMARKS: Film thicknesses/ consumption:

Appearance: Note: ISSUED:

HEMPADUR SEALER 05990 is used for saturation of the absorbent concrete surface. Application should be initiated by assessing the degree of dilution in order to obtain a correct result. The actual amount of thinner required will depend on temperatures, the surface and type of the concrete and the actual application technique. Furthermore, a practical theoretical spreading rate cannot be calculated. For practical purposes, approx. 10 m/litre (410 sq.ft./US gallon) is indicated depending on the surface roughness, porosity of the concrete, and the application method. In any case a glossy surface must not appear and such a surplus of HEMPADUR SEALER 05990 must be removed by sanding , abrasive sweep-blasting or similar methods before painting takes place. HEMPADUR SEALER 05990 is for professional use only. September 2002 - 0599000000CS004 HEMPELS MARINE PAINTS A/S

This Product Data Sheet supersedes those previously issued. For definition and scope, see explanatory notes to applicable Product Data Sheets. Data, specifications, directions and recommendations given in this data sheet represent only test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual conditions of any intended use of the Products herein must be determined exclusively by the Buyer and/or User. The Products are supplied and all technical assistance is given subject to HEMPEL's GENERAL CONDITIONS OF SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed in writing. The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed in said GENERAL CONDITIONS for all results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf or otherwise. Product data are subject to change without notice and become void five years from the date of issue.

HEMPEL

Product Data Sheet

Page 1/2

Product Data
Description: Recommended use: Availability: PHYSICAL CONSTANTS: Colours/Shade nos.: Finish: Volume solids, %: Theoretical spreading rate: Flash point: Specific gravity: Dry to touch: V.O.C.:

HEMPEL'S HI-VEELACQUER 06520

HEMPEL'S HI-VEE LACQUER 06520 is a non-yellowing, clear varnish based on acrylic resin dissolved in white spirit. Physically drying. The inclusion of a UV absorber serves to protect the preceding paint film against ultraviolet radiation. Further benefits are water and dirt repellent properties. For protection of HEMPEL'S HI-VEE 56540, especially in outdoor exposure, to maintain the high visibility (HI-VEE) of the fluorescent effect. Not recommended for surfaces subject to excessive wear. Part of Group Assortment. Local availability subject to confirmation. Transparent/00000 Glossy 27 1 10.8 m/litre - 25 micron 433 sq.ft./US gallon - 1 mil 32C/90F 0.9 kg/litre - 7.7 lbs/US gallon 1-2 hours at 20C/68F 580 g/litre - 4.8 lbs/US gallon

The physical constants stated are nominal data according to the HEMPEL Group's approved formulas. They are subject to normal manufacturing tolerances and where stated, being standard deviation according to ISO 3534-1. Further reference is made to "Explanatory Notes" in the HEMPEL Book.

APPLICATION DETAILS: Application method:

Best results are obtained with a flat varnish brush. Spray application is possible with most types of spray equipment after thinning with THINNER 08230, but this application method is mainly subject to specific local conditions, so no general guidelines can be given. THINNER 08230 25 micron/1 mil 100 micron/4 mils 3 hours (20C/68F) none (See REMARKS overleaf

Cleaning of tools: Indicated film thickness, dry: Indicated film thickness, wet: Recoat interval, min: Recoat interval, max:

Safety:

Handle with care. Before and during use, observe all safety labels on packaging and paint containers, consult HEMPEL Material Safety Data Sheets and follow all local or national safety regulations. This goes for personal protection such as, but not limited to, protection of lungs, eyes and of the skin, medical treatment in case of swallowing the paint or in case of other direct contact with the paint. Take necessary precautions against possible risks of fire or explosions as well as protection of the environment. Apply only in well ventilated areas and ensure that adequate forced ventilation exists when applying paint in confined spaces or when the air is stagnant.

Issued:

October 1999

HEMPEL
HEMPEL'S HI-VEE LACQUER 06520 APPLICATION CONDITIONS: PRECEDING COAT: SUBSEQUENT COAT: REMARKS: Note: ISSUED:

Product Data Sheet

Page 2/2

As dictated by normal good painting practice. In confined spaces provide adequate ventilation during application and drying. HEMPEL'S HI-VEE 56540. None. No maximum recoating interval, but after prolonged exposure to polluted atmosphere, remove accumulated contamination by (high pressure) fresh water cleaning and allow to dry. HEMPEL'S HI-VEE LACQUER 06520 is for professional use only. October 1999 - 0652000000CO007 HEMPELS MARINE PAINTS A/S

This Product Data Sheet supersedes those previously issued. For definition and scope, see explanatory notes to applicable Product Data Sheets. Data, specifications, directions and recommendations given in this data sheet represent only test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual conditions of any intended use of the Products herein must be determined exclusively by the Buyer and/or User. The Products are supplied and all technical assistance is given subject to HEMPEL's GENERAL CONDITIONS OF SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed in writing. The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed in said GENERAL CONDITIONS for all results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf or otherwise. Product data are subject to change without notice and become void five years from the date of issue.

HEMPEL

Product Data Sheet

Page 1/2

Product Data

HEMPELS THINNERS 08...

HEMPEL PAINT is produced and supplied in such a way that thinning is normally not necessary provided the paint is properly mixed/stirred. However, if the paint is to be applied in a low film thickness (for instance as a "sealer coat") or if the paint has become too thick, e.g. in cold weather, the HEMPEL THINNER(s) indicated on the product data sheet may be added to obtain a consistency most suitable for application. As a general rule, thinning should be kept at a minimum as the quality of the paint work will suffer from too liberal thinning. However, if application is to take place at high temperatures (air and/or steel), thinning may even beyond the limits mentioned on the data sheets exceptionally be necessary in order to avoid dry-spray and poor film formation. HEMPELS THINNERS are blended to give the best results with regard to brushability, spray properties, etc. In some cases ordinary solvents may substitute. As such products are beyond our control, we disclaim any responsibility for the results. In each case the respective product data sheet and - when available - the APPLICATION INSTRUCTIONS should be consulted. As regards the use of THINNERS for cleaning of tools, see REMARKS overleaf. FLASH POINT (Setaflash closed cup)

HEMPELS THINNER NO.

EXAMPLES OF GENERAL USE

08080

25C/77F

HEMPELS ANTIFOULINGS NAUTIC SP-ACEs, ECONOMIC SP-SEA and GLOBIC SP-ECO HEMPALIN DECKPAINT 53240. HEMPAQUICK qualities All-purpose thinner for HEMPATEX qualities. HEMPATHANE topcoats and enamels.

08230

32C/90F

Thinner for HEMPALIN qualities (except HEMPALIN DECKPAINT 53240 and HEMPAQUICK qualities) and other alkyd-based products.

08450

23C/73F

General purpose thinner for HEMPADUR qualities.

08510

3C/37F HIGHLY FLAMMABLE

Special purpose thinner for HEMPATHANE ENAMEL 55100 HEMPATHANE TOPCOAT 55210

08570

4C/39F

HEMPELS SHOPPRIMER E 15280 HEMPELS SHOPPRIMER ZS 15722 HEMPELS SHOPPRIMER ZS 15890

Issued:

October 1999

HEMPEL
HEMPELS THINNERS 08...

Product Data Sheet

Page 2/2

HEMPELS THINNER NO.

FLASH POINT (Setaflash closed cup)

EXAMPLES OF GENERAL USE

08700

24C/75F

HEMPELS GALVOSILs For HEMPADURs used as non-popping sealers on GALVOSILs.

REMARKS:

THINNER 08230 has a stronger thinning effect than white spirit or turpentine. Tools can usually be cleaned with the THINNER prescribed for the product. For cleaning of tools which have been used for HEMPADUR products, HEMPELS TOOL CLEANER 99610 is recommended. Do not use it for thinning, nor for cleaning after use of polyurethane products, HEMPATHANEs. HEMPEL'S THINNERS are for professional use only. October 1999 HEMPELS MARINE PAINTS A/S 0808000000CO004 0823000000CO005 0845000000CO009 0851000000CO002 0857000000CO007 0870000000CO006

Note: ISSUED:

This Product Data Sheet supersedes those previously issued. For definition and scope, see explanatory notes to applicable Product Data Sheets. Data, specifications, directions and recommendations given in this data sheet represent only test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual conditions of any intended use of the Products herein must be determined exclusively by the Buyer and/or User. The Products are supplied and all technical assistance is given subject to HEMPEL's GENERAL CONDITIONS OF SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed in writing. The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed in said GENERAL CONDITIONS for all results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf or otherwise. Product data are subject to change without notice and become void five years from the date of issue.