TMB Installation Guidelines

For more detailed information see TMB Technical user manual LG-MF00033.

WARNING DANGER FOR THE 115/230 VAC VERSION


High voltage 115 / 230 VAC Product must ONLY be installed by suitably qualified personnel.

HIGH LEAKAGE CURRENT FOR THE 115/230 VAC VERSION


Earth connection essential before connecting supply Notice! TMB START UP Install TMB grounding wire properly before connecting TMB to AC power line Notice! TMB SHUT DOWN Disconnect TMB from AC power line before removing ground wire

ATTENTION
Do not paint the heat sinks. Do not restrict free airflow from the heat sink. Remove the handle when not in use.

Lifting / hoisting the TMB Note: Be sure that the handle is locked correctly. Note: When hoisting a TMB it is strongly recommended to avoid collisions between TMB and tower by having a steering rope from the TMB and down to the ground.

Mounting the TMB on a wall

TMB packing list Standard package: 1. TMB unit 2. Mounting plate for the TMB 3. CIU incl. BTS interface cable 4. Mounting plate for the CIU 5. Power supply connector 6. Two TNC connectors 7. Test sheet incl.unit specific data 8. TMB Installation Guidelines 9. CIU cable (30 metres) 10. Two steel bands for mounting the CIU Extra: Handle/lifting wire, RS232 cable to the PC (4 metres), disk/CD containing PC software, Technical Product Manual

Figure 1

TMB with handle Figure 2 Mounting Plate

Step 1:
Handle / lifting wire is connected to the two bolts located on the big heat sink.

Fit the Mounting Plate on the wall. Hook the TMB on to the plate. Tighten the 4 screws.

Step 2: Step 3:

Pole mount.: Two inner clamp halves, two outer clamp halves, 4pcs M8 x 12 mm bolts , 4pcs M10 x 200 mm bolts, 4pcs M10 x 140 mm bolts Mounting the TMB on a vertical / horizontal pole Note: The TMB shall always be installed upright to ensure best cooling. If at all tilted make sure the TMB is tilted backwards and maximum 5 degrees.

Note: The handle should be removed after the installation.

Step 2: Join the inner clamp halves (c) and the mounting plate, using the four M8 x 12 mm bolts (d).

Step 5: Position the clamps around the pole and insert the two remaining bolts (M10x200 mm or M10x140 mm). Position (e) on figure 4. Tighten all four bolts, taking care to keep the two halves of each clamp parallel.

b e

Pole diameter: 60 90 mm Pole diameter: 90 140mm

Use bolt M 10 x 140 mm Use bolt M 10 x 200 mm


c

Figure 5

Step 1: Check that the four mounting screws (a) on the back of theTMB are loosened to enable slotting on to the mounting plate. The screws cannot drop out.
a a

Figure 4

Step 6: Position the TMB and tighten the four locking bolts (a).

Step 3: Then mount the outer clamps (b) loosely, each with one of the long bolts (e) (M10 x 200 mm or M10 x 140 mm). Check that there is enough space for the pole.

Step 4: Finally check that the two remaining long (e) bolts are accessible.
Figure 3 Figure 6
LG-MF:00069 Rev. D TMB Installation Guidelines

Mounting of the CIU The CIU mounting plate is prepared for wall mounting as well as pole mounting. Wall: Screw the mounting plate on to the wall. Use the holes located on the CIU mounting plate. Pole: Use a plastic strap or a steel band. Slide the CIU down on the mounting plate and lock it with the set screw found on the side of the CIU. Alarm output Relay #2 Alarm output Relay #1 A1-0 A1-1 A1-2 A2-0 A2-1 A2-2 A3-0 A3-1 A3-2 A4-0 A4-1 A4-2 Function Connection

Alarm interface cable to BTS and Alarm functionality Colour Red/Blue Red Blue Grey/Pink Grey Pink Black White Green Brown Violet Yellow Connection Alarm No Alarm

A1-1 to A1-0 A1-2 to A1-0

Closed Open

Open Closeed

A2-1 to A2-0 A2-2 to A2-0

Closed Open

Open Closed

Alarm output Relay #3

A3-1 to A3-0 A3-2 to A3-0

Closed Open

Open Closed

Figure 7

Alarm output Relay #4

A4-1 to A4-0 A4 -2 to A4-0

Closed Open

Open Closed

CIU/TMB Communication Cable - Recommended cable type: RG58 - Max. attenuation: 20dB @ 10 MHz - Max. DC resistance: 10 ohm - Recommended connector: Water proof TNC

Power Supply Cable Note: It is essential that the power supply cable is properly dimensioned and securely attached to the tower/building. Note: It is recommended that the main power supply cable for the TMB is connected to a separate circuit breaker at the base.
115/230 VAC The outer dimension of the power cable shall be 6-8 mm. The connector has three terminals.

Connecting the earth cable The TMB cabinet and CIU must be connected to a suitable earth point. Fit the lug of the earth cable over the bolt and then fit the locking washer. Secure the lug and washer with the outermost nut.

Note:

Connecting the cables Connect the RF feeder cables to the respective RF connectors at the bottom plate of the TMB. The RF connectors are clearly marked ANT and BTS.

They are clearly marked: N = Neutral L = Line (phase or positive) 0 = Earth (ground)
Ground Neutral

It is recommended to use a 16 mm cross section grounding wire.

G ro unding

Figure 9

Figure 11 View of the pin configuration of

CIU interface Fuse Antenna # 1 Antenna # 2

the power supply connector located in the bottom of the TMB.


Phase Line/phase Guide / grip

48 VDC

BTS # 1

BTS # 2

Note:

The voltage at the TMB must be at least 40 VDC. Please refer to the technical user manual for cable dimensions

ATTENTION! It is very important that + and - are connected correctly to the terminals of the power connector.

Power connector

Figure 8

On the drawings the Power connector is seen from the cable side. The connector is marked with numbers and ground symbol: Terminal 4 must be connected to the positive voltage. Terminal 5 must be connected to the negative voltage. Ground terminal must be connected to the ground.

Note:

Be sure always to connect the RF feeder cables and the grounding wire before the power cable. This is to ensure that the power plug is not damaged if knocked by the spanner while thightening the RF connectors. Please note that the 48 VDC version do not have any external fuse.

Note:

Inside the TMB + and - are isolated from ground. This makes it possible to provide the TMB with both +48 VDC or -48 VDC. LG-MF:00069 Rev. D TMB Installation Guidelines