Вы находитесь на странице: 1из 329

CALPEDA, 50 YEARS OF HISTORY

We want to continue that which was started many years ago by Vinicio Mettifogo,
founder and pioneer.
Today, we are a reality that has evolved over the years, always looking to the future
with a spirit that has brought us to being a respected reference point in the great
world of water.
A 50-year old history that has taken our tradition and strength to you,
acknowledged for our professionalism, quality, reliability and service.

CALPEDA TODAY
Employees: 250
Offices: Montorso V. (Vicenza) Italy
Main factory: 30,000 sq. metres (covered)
Types of pumps: more than 2,000
Power outputs: from 0.5 kW to 200 kW

INDEX
1

NM, NMD

MGP

pag. 7

pag. 79

Close coupled centrifugal pumps


with threaded ports

Horizontal multi-stage
close coupled pumps

NM

MXSU

pag. 17

pag. 81

Close coupled centrifugal pumps


with flanged connections

Vertical multi-stage close coupled


stainless steel pumps

10

NM4

MXV-B

pag. 29

pag. 83

Close coupled centrifugal pumps


n = 1750 rpm

Vertical multi-stage close coupled


stainless steel pumps

11

N, N4

MXV

pag. 43

pag. 89

End-suction centrifugal pumps


EN 733

Vertical multi-stage in-line


stainless steel pumps

NR, NR4

11.1

MXVL

pag. 53

pag. 105

In-line pumps

Vertical multi-stage in-line


stainless steel pumps AISI 316L

MXH 2,4,8,16
NEW

pag. 65

MXV-E

pag. 109
Variable speed multi-stage
vertical pumps

Horizontal multi-stage
stainless steel pumps

6.1

12

13

MXHL

SPA

Compact Spa

pag. 69

pag. 119

Horizontal multi-stage
stainless steel pumps AISI 316L

Self-draining whirpool pumps

6.2

MXH 32,48
NEW

pag. 73
Horizontal multi-stage
stainless steel pumps

MXP

14
pag. 121

MPC

Compact Pool

Self-priming swimming pool pumps


with built-in strainer (plastic pumps)

15

NMP

pag. 77

pag. 123

Horizontal multi-stage
close coupled pumps

Cast iron self-priming centrifugal pumps


with built-in strainer

INDEX
16

25

PF

MXA

pag. 127

pag. 161

Pre-filters in stainless steel

Horizontal multi-stage
Self-priming pumps

17

26

I, IR

pag. 129

pag. 163

Self-priming centrifugal pumps


with open impeller

Gear pumps

18

27

B-VT

pag. 133

pag. 165

Centrifugal pumps
with open impeller

Peripheral immersion pumps

19

28

CT 61

VAL, SC

pag. 137

pag. 167

Peripheral pump

Vertical submerged pumps


with free-flow impeller and open impeller

20

29

T, TP

GM 10

pag. 139

pag. 171

Peripheral pumps

Submersible drainage pump

21

CA

NEW

30

GXR, GXV

pag. 145

pag. 173

Self-priming liquid ring pumps

Submersible drainage pump


stainless steel pumps

22

NGL

31

GX 40

pag. 149

pag. 177

Self-priming jet pumps

Submersible stainless steel pumps

23

NGX

32

GM 50

pag. 153

pag. 179

Self-priming jet pumps

Submersible pumps with single-channel


or free-flow impeller

24

NG

33

GEO

NEW

pag. 157

pag. 183

Self-priming jet pumps

Automatic waste water collecting


and lifting station

INDEX
34

43

GM

AUE,
AUD, AUED

pag. 197

pag. 321

Submersible pumps

UNI-EN 12845 units for feeding


fire-extinguishing systems

35

44

MXS

Accessories

pag. 259

pag. 329

Stainless steel multi-stage submersible


clean water pumps

Accessories for pumps

TEMPERATURA ACQUA IN GRADI CENTIGRADI

SD, SDF, SDN

BATTENTE POSITIVO IN
ASPIRAZIONE (m.c.a.)

36

10

20

30

40

50

60

70

80

90

100

110

4
3
2

45

1
0
1

pag. 263

SDX

pag. 280
Stainless steel submersible bore-hole
pumps for 6 and 8 wells

38

SDS

pag. 289
Submersible bore-hole pumps
for 4 - 6 - 8 and 10 wells

39

CS

pag. 301
Submersible motors
for 4 - 6 - 8 and 10 wells

40

NC3, NCS3

pag. 305
Three speeds circulating pumps

41

IDROMAT

pag. 311
Electronic regulator for pumps

42
pag. 313

Pressure boosting
plants

Fixed speed pump units


Variable speed pump units with frequency converter

PREVALENZA MANOMETRICA IN
ASPIRAZIONE (m.c.a.)

Submersible bore-hole pumps


for 4and 6 wells

37

pag. 331

2
3
4
5

IC
AT
A PR
CURV

7
8
9

CURVA

TEO R

I CA

10
11

10

20

30

40

50

60

70

TEMPERATURA ACQUA IN GRADI CENTIGRADI

80

90

100

110

Technical
appendix

NM, NMD

60 Hz

Close Coupled Centrifugal Pumps


with threaded ports

Construction
Close-coupled, centrifugal pumps; electric motor with
extended shaft directly connected to the pump.
NM: single-impeller
NMD: with two back-to-back impellers (with axial thrust
balancing).
Connections: threaded ports ISO 228/1 (BS 2779).
The pumps in bronze are supplied fully painted.

Applications
- For clean liquids without abrasives, which are, non-aggressive
for the pump materials ( solids content up to 0.2%).
- For water supply.
- For heating, air-conditioning, cooling and circulation plants.
- For civil and industrial applications.
- For fire fighting applications.
- For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar
(16 bar for pumps NMD 25/190; NMD 32/210; NMD 40/180).
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
NM, NMD:
three-phase 220/380 V, 380/660 V.
NMM, NMDM: single-phase 220 V.
With thermal protector up to 1.1 kW.
Insulation class F.
Protection IP 54.
Constructed in accordance with IEC 60034.

Materials
Components
Pump casing
Lantern bracket
Impeller
NM 17

NM, NMD
B-NM, B-NMD
Cast iron
Bronze
G-Cu Sn 10 EN 1982
GJL 200 EN 1561
Brass P- Cu Zn 40 Pb 2 UNI 5705
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cr steel AISI 430
Cr Ni Mo steel
Cr Ni steel AISI 303
AISI 316
1,1 -1,5 - 2,2 kW
Carbon - Ceramic - NBR

Shaft

Mechanical seal

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


5
4

U.S. g.p.m.

10

Imp. g.p.m.

20

30

10

20

40
30

50

100

40

50

200
100

300
200

400
300

130

400
NMD 32/210

100

NM, NMD

300

NMD 25/190

NMD 40/180

200

NMD 20/140

50

NM 3

40

NM 25/20

ft

NM 12

30

NMD 20/110

NM 20/160 NM 25/160

NM 2

100
90
80
70
60

NM 11

20
NM 25/12

NM 1

NM 10

50
40

NM 17
10

30

20
5
4
1

m /h

Q l/min

30

40

3
50

6 7
100

8 9 10
150

200

20
300

400

30
500

40

50
1000

100
1500
72.823.C

NM, NMD

60 Hz

Close Coupled Centrifugal Pumps


with threaded ports

Performance n 3450 rpm

P2

NM

NM
NM
NM
NM
NMM
NM
NMM
NM
NM

1/AE-60
2/B-60/A
2/S-60/A
2/A-60/A
3/CE-60
3/CE-60
3/BE-60
3/BE-60
3/AE-60

B-NM

NM

B-NMD

NMD

B-NMD 20/110B-60/A
B-NMD 20/110Z-60/A
B-NMD 20/110A-60/A
B-NMDM 20/140BE-60
B-NMD 20/140BE-60
B-NMDM 20/140AE-60
B-NMD 20/140AE-60
B-NM
20/160BE-60
B-NM
20/160AE-60

NMD 20/110B-60/A
NMD 20/110Z-60/A
NMD 20/110A-60/A
NMDM 20/140BE-60
NMD 20/140BE-60
NMDM 20/140AE-60
NMD 20/140AE-60
NM
20/160BE-60
NM
20/160AE-60

B-NM

NM

B -NMD

NMD

B-NM
B-NM
B-NM
B-NM
B-NM
B-NM
B-NM
B-NMD
B-NMD
B-NMD

25/12B-60/A
25/12A-60/A
25/160BE-60
25/160AE-60
25/200BE-60
25/200AE-60
25/200SE-60
25/190CE-60
25/190BE-60
25/190AE-60

kW

HP

0,37
0,55
0,55
0,75
1,1
1,1
1,5
1,5
2,2

0,5
0,75
0,75
1
1,5
1,5
2
2
3

P2
kW

HP

0,45
0,55
0,75
1,1
1,1
1,5
1,5
0,75
1,1

0,6
0,75
1
1,5
1,5
2
2
1
1,5

kW

HP

NM 25/12BE-60/A 0,55
NM 25/12AE-60/A 0,75
NM 25/160BE-60 1,1
NM 25/160AE-60 1,5
2,2
NM 25/20BE-60
3
NM 25/20AE-60
4
NM 25/20SE-60
2,2
NMD 25/190CE-60
3
NMD 25/190BE-60
4
NMD 25/190AE-60

0,75
1
1,5
2
3
4
5,5
3
4
5,5

NM
NM
NM
NM
NMM
NM
NM
NM
NM
NM

10/FE-60
10/DE-60
10/AE-60
10/SE-60
11/BE-60
11/BE-60
11/AE-60
12/DE-60
12/CE-60
12/AE-60

1,2

1,5

1,89

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

l/min

16

20

25

31,5

40

50

60

70

80

90

100

110

125

140

22
27
32
36

21,8
26,5
31,5
35,5
39,5
40
45,5
47
55,5

21,5
26
31
35
39
39,5
45
46,5
55

21
25,5
30,5
34,5
39
39,5
45
46
54,5

20,3
25
30
34
38
39
44,5
45,5
54

19,4
24
28
32,5
37
38
44
45
53,5

18,1
23
25,5
31,5
36,5
37
43
44,5
53

16,3
22
23
30
35
36
42
43,5
52,5

14,2
20
19,5
28,5
33,5
34
41
42
52

32*
39*
40*
51*

29*
36*
37*
49*

32*
33,5*
46,5*

28*
42*

35*

H
m

P2
kW

HP

0,55
0,75
1,1
1,5
1,5
1,5
2,2
2,2
3
4

0,75
1
1,5
2
2
2
3
3
4
5,5

27

Q
m3/h

1,2

1,5

1,89

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

l/min

16

20

25

31,5

40

50

60

70

80

90

100

110

125

140

36,5
41
47
59
60
66,5
77

35,5
40
46,5
58,5
59,5
65,5
76,5

34
38
45
58
59
65
76

32
36
42,5
57
58
64
75
33
39

28,5
32,5
39
55
56
62,5
73,5
33
38,5

24
28
34
52
53
60
71
32
38

19*
23
29
47,5
49
57,5
69
31
37

45
55
66
30
36

51
63
28,5
35

47,5
59
26,5
34

54
25
33

23*
31*

4,8

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

250

280

H
m

Q
m3/h

P2

NM

Q
m3/h

l/min

2,4

3,6

17*
23,5*

40

50

60

80

100

110

125

140

160

180

200

220

20,8
24,5

20,8
24,6
32
38
46
53
60
67
80
97

20,7
24,6
31,5
37,5
45,5
52,5
59,5
65
78
95

20,3
24,3
31
37
45
52
59
60
73
92

19,6
23,6
30
36
44
51,5
58,5
53
67,5
87

19,2
23,1
29
35,5
43,5
48,5
58
50
64
84

18,4
22,4
28
34,5
42,5
50
57,5
42
58
79

17,6
21,6
26,5
33
41,5
49
56,5

16,1
20,4
23,5*
31
39
47,5
55

14,3
19

12
17

9,3
14,5

27,5
36,5
45,5
54

22,5*
33*
43
52

40*
50

51,5
72,5

41*
63*

H
m
69
81
98

45,5

Q
m3/h

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

l/min

110

125

140

160

180

200

220

250

280

315

350

400

450

500

13,5
19
24
26
29
30,5
36
38
44,5
56,5

13
19
24
25,5
28,5
30
35,5
37,5
44
56

12,5
18,5
23,5
25,5
28
29,5
35
36,5
43
55,5

12
18
23
25
27
29
34
35
42
55

11,5
17,5
22
24,5
26
28
33
34
41
54

10,5
16,5
21,5
24
25
27
32,5
32*
40
53

9
15,5
20
22,5
22,5
25
31

21
20
23*
29*

19

16,5

12,5

H
m

14
19,5
24,5
26
29,5
31
36,5
39
45
57

37
51

34*
49*

NM, NMD

60 Hz

Close Coupled Centrifugal Pumps


with threaded ports

Performance n 3450 rpm

1
P2

B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD

NMD

32/210DE-60
32/210CE-60
32/210BE-60
32/210AE-60
40/180DE-60
40/180CE-60
40/180BE-60
40/180AE-60

NMD
NMD
NMD
NMD
NMD
NMD
NMD
NMD

B-NM

B-NM
B-NM
B-NM
B-NM

32/210DE-60
32/210CE-60
32/210BE-60
32/210AE-60
40/180DE-60
40/180CE-60
40/180BE-60
40/180AE-60

kW

HP

4
5,5
7,5
9,2
4
5,5
7,5
9,2

5,5
7,5
10
12,5
5,5
7,5
10
12,5

P2

NM

17/HE-60
17/GE-60
17/FE-60
17/DE-60

NM
NM
NM
NM

17/HE-60
17/GE-60
17/FE-60
17/DE-60

kW

HP

1,1
1,5
2,2
3

1,5
2
3
4

Q
m3/h

5,4

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

l/min

90

100

110

125

140

160

180

200

220

250

280

315

350

400

68
89
110
121

67
88
109
120

65
87
108
119

63
85
106
118
60
68
86,5
93,5

60
83
104
117
58,5
67,5
86
92,5

55
79
100
114
57
66,5
84,5
91,5

50
74
96
110
55,5
65,5
83,5
90,5

45
68
91
105
53,5
64
82
89

40*
63
86
99
51,5
63
80
87

52*
78*
89*
47,5
59,5
77,5
84,5

43,5
57
74
83

38,5
50
68
75,5

33,5
47,5
65,5
73,5

58*
66*

54

60

66

75

84

96

1250

1400

1600

H
m

Q
m3/h

21

24

27

30

33

37,8

42

48

l/min

350

400

450

500

550

630

700

800

900

1000

1100

9,2
12

9
11,8
16

8,7
11,6
15,8
18

8,5
11,5
15,5
17,7

8
11
15
17,5

7,5
10,5
14,5
17

6,5
9,5
14
16,5

5
8
12,7
15,5

3,5*
6,5
11,5
14

4,5*
10
12,5

8*
11*

H
m

NM, NMD
Standard construction.
B-NM, B-NMD Bronze construction.

P2 Rated motor power output.


H Total head in m.

Rated currents
P2
kW

HP

220 V
1~
IN A

0,37
0,45
0,55
0,75
1,1
1,5

0,5
0,6
0,75
1
1,5
2

3,4
4,1
5,2
6,5
8,5
10,6

P2
IA/IN

kW

HP

2,3
2,5
3,1
2,9
3
3,8

0,37
0,45
0,55
0,75
1,1
1,5
2,2
3
4

0,5
0,6
0,75
1
1,5
2
3
4
5,5

5,5
7,5
9,2

7,5
10
12,5

220 V / 380 V Y
380 V / 660 V Y
IN A
IN A
IN A
3
2,6
3,3
4,5
5,7
9
10,7
13

IA/IN

1,7
1,5
1,9
2,6
3,3
5,2
6,2
7,5
11,3

6,5

3,8
3,5
4,3
5,2
5,3
6
5,9
9,5
9,8

14,5
18,2
21,5

8,4
10,5
12,4

8,2
9,5
8,2

P2
Rated motor power output.
IA/IN D.O.L. starting current / Rated current

With single-phase motor = NMM - NMDM.


Maximum suction lift 1-2 m.
Tolerances according to ISO 9906, annex A.

NM

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Characteristic curves n = 3450 rpm


25

0 U.S. g.p.m. 5
0 Imp. g.p.m. 5

10

A 113

15

10

43 45

46

15

0 U.S. g.p.m. 5
0 Imp.g.p.m. 5

30

45 50

20

10

A 143

70
ft
60

D 46,5%

46

40

80

NM 1

39 41

20

15

20

15

10
30

15

35 37.5
40

20

20

25

NM 2/A-B

120
ft
100

D 42%

B 124

80
60

40
10
0 Q m3/h 1
0.60

0.50
P
0.40
kW
0.30

0.20
6
NPSH
4
m
2
0

40

0 Q m3/h 1

0 U.S. g.p.m. 5
0 Imp. g.p.m. 5

H
m

S 135

3
10

30

35

30

4
15

10

15

40

0.6
P
0.5
HP
0.4

15
NPSH
10
ft
5
0

120

0.2
3
NPSH
2
m
1
0 Q m3/h 1

100
ft
80

6
1.2
1.0
P
HP
0.6
0.4

3
20

A 171 30

30

20

72.501

16
12
NPSH
ft
4
0

40

30

NM 3

34 35

180
160
ft
140

D 36%

B 3~ 158

35
34

B 1~ 156
C 3~ 1
47
C 1~
14

120

100

30

80
20

1.2
S 1.0
P
0.8
HP
0.6
0.4

0 U.S. g.p.m. 10
0 Imp. g.p.m. 10

40

72.502

0 Q m3/h 1

m
50

40
2

60

0 Q m3/h 1

0.2
6
NPSH
4
m
2

60

40

0.8
P
0.6
kW
0.4

20

D 41%

0.8
P
0.6
kW
0.4

NM 2/S

20

10

72.500

40

10
0 Q m3/h 1
1.0

0 Q m3/h 2

3
P
2
kW
1

A
C

0
6
NPSH
4
m
2

8
NPSH
ft
4
2
0

0
10

10

0 Q m3/h 2

4
P
3
HP
2
1
0
16
12
NPSH
ft
4
0
72.503 10

NM

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Characteristic curves n = 3450 rpm


30

H
m

20

0 U.S. g.p.m. 20
0 Imp.g.p.m. 20

40

40

S 116

58 61

A 114
D 103

60

80

60

63 64

100
80

40

NM 10

D 65%

6463

61

F 88

80
ft
60

58

30

0
8
6
NPSH
4
m
2
0
0 Q m3/h 5

70

60
m
50
40

0 U.S. g.p.m. 20
0 Imp.g.p.m. 20

10

15

25

20

A
D
F

40

15

40

A 178

60

45 47,5

20

60

50

C 164
D 153

20

2
P
HP
1

2.4
2.0
P
kW
1.2
0.8

80

D 52%

72.504

25

200
ft
150

50

100

20
10

15

15

20

110
ft
100
90
80
70

0 Q m /h
3

0
8
6
NPSH
4
m
2
0
0 Q m3/h
11

120

54
55
D 57%

10

15

20

B 3~
B 1~

10
200
100
50 55 60
62,5
64

3.5
3
P
HP
2
1.5
1

20
NPSH
10
ft
0
72.505 20

15

100

300

200

60

NM 17

D 65%

50
ft
40

62,5
60

30
20

55

10
20

40

80

60
D
F

3
P
2
kW
1

20
NPSH
10
ft
0
72.506 25

130

53

B 1~ 128

0
0 Q m3/h
4

25
6
P
HP
4
3
2
1
0

A
C

10

20

20

50

50

80

NM 11

B 3~ 131

0 U.S. g.p.m.
0 Imp. g.p.m.
20
D 110
F 105
15
H G 94
m
10 H 88

100
80

NM 12

20

A 146

8
6
NPSH
4
m
2
0
0 Q m3/h

20
NPSH
10
ft
0

30

10
0 Q m3/h 5
5
4
P
kW
2
1
0
8
6
NPSH
4
m
2
0
0 Q m3/h 5

10

60

25

20
0
0 Q m3/h 5
2
P
kW
1

40

m
35

40

10

0 U.S. g.p.m. 20
0 Imp.g.p.m. 20

20

40

60

5
4
P
3
HP
2
1
0

20
NPSH
10
ft
0
72.507 80

NM

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Characteristic curves n = 3450 rpm


   


 




B   

  




A   

NM 20/160





A  



 

 

B  


 







NM 25/12








D  






D 


















Q 

Q 

A
B







Q 

  











NM 25/160




A  

 

B   











Q 



 








D  

A




Q 



















 


 

 

Q 






S




A
B







Q 
















D 




















NM 25/20



B  





S   




















  


























A
B



12







Q 







NMD

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Characteristic curves n = 3450 rpm


60

0 U.S. g.p.m. 5
5
0 Imp.g.p.m.

 118/1
18
 111/1
11
 115/9
8

50

m
40

10

25

15

10

15

180



160
ft
140

30
D 33%

120

30

100

30

35

15

20

20

25

38

240
ft
200

D 39%

38 160
120

60
0

m /h 1
3

1.0
P
0.8
kW
0.6





0.4
6
NPSH
4
m
2
0

15

40

80

20
10

10
0 U.S. g.p.m. 5
10
0 Imp.g.p.m. 5
80
 143/14
3 - 3~ 30

m
 134/1
34 - 1~
 127/1
60
27 - 3~
 127
/127 - 1~

20

m3/h 1

72.540

40

20
0
2.5

1.4
1.2
P
1.0
HP
0.8
0.6

80

m /h 1
3

2
P
1.5
kW
1

0.5
6
NPSH
4
m
2

16
12
NPSH
ft
4
0

13

m3/h 1

6
 3~ 3
 1~ P
HP
2
1.5
1

72.541

16
NPSH
ft
8
4
0

NMD

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Characteristic curves n = 3450 rpm


0 U.S. g.p.m. 10
0 Imp.g.p.m. 10
110
A 162/166
100

m
80

20

30

20

30 32,5

B 150/150

30

35

60
50

80

200

35

34

40

12

A
C

1
8
NPSH
6
m
4
0 Q m3/h 2

0 U.S. g.p.m.
0 Imp.g.p.m. 20
100 A 172/156
B 156/156

40

40

8
60

60

40

45

80

C 142/142
m D 136/136
60

47

44

40

10
80

100

20
0 Q m3/h 3
12
10
P
kW
6
4
2
8
6
NPSH
4
m
2
0
0 Q m3/h 3

6
P
HP
4
3
2

25
NPSH
20
ft
15
10
72.542 12

100
80

NMD 40/180

300
ft

45

D 48%

200

40
100

20
0 Q m3/h 5
10
P
kW
5
0
8
6
NPSH
4
m
2
0
0 Q m3/h 5

10

15

20

A
B
C
D

26
10
P
HP
5
0

10

15

20

60
50

20
NPSH
10
ft
0
72.544 26
14

70
60
ft
400

NMD 32/210
35

320

36
D 36,5%

D 145/145

240

35

160

33

40

10

50
40

60

32,5
30

4
P
3
kW
2

300
ft

D 37%

36

30
0 Q m3/h 2
5

40

30
40
0 U.S. g.p.m. 20
30
20
0 Imp.g.p.m.
140
A 186/186
30
120
B 186/174
H
m
100
C 165/165

50

NMD 25/190

C 140/142

70

40

12

15
A
B
D

18

80
16
P
12
HP
8
4

12

15

25
20
NPSH
ft
10
5
0
72.543 18

NM

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Dimensions and weights

1
NMM
TYPE
NM 1/AE-60
NM 2/B-60/A
NM 2/S-60/A
NM 2/A-60/A
NM 3/CE-60
NM 3/BE-60
NM 3/AE-60
B- NM 20/160BE-60
B- NM 20/160AE-60
B- NM 25/12B-60/A
B- NM 25/12A-60/A
B- NM 25/160BE-60
B- NM 25/160AE-60
NM 25/20BE-60
NM 25/20AE-60
NM 25/20SE-60
B- NM 25/200BE-60
B- NM 25/200AE-60
B- NM 25/200SE-60
NM 10/FE-60
NM 10/DE-60
NM 10/AE-60
NM 10/SE-60
NM 11/BE-60
NM 11/AE-60
NM 12/DE-60
NM 12/CE-60
NM 12/AE-60
B- NM 17/HE-60
B- NM 17/GE-60
B- NM 17/FE-60
B- NM 17/DE-60

f
a

l1
DN2

l2

DN2

h3

DN1

h2

g1 h1
4.93.098

m2

n3

m1

b
n2

B-NM

kg

kg

kg

8,7
14
14,2
15,1
24
26

8,6
13,1
13,3
14,2
22,9
25,1
26,1
18,4
19,7
12,3
13,3
19,7
21,5
28,6
37,9
41,7

19,9
20,7
13,2
14,2
20,4
22,5

21
22,5
13,5
14,5
22,8
24

32,7
40,7
44,7
19,3
19,4
20,2
22,1
24,7

18,5
18,8
19,3
21,5
24,1
25,1
30,5
39
43
22,2
23,2
25,2
33,2

23
24,2

29,2
30,2
32,2
40,2

n1

mm

DN1
B-NM

NM

NM

NM 1/AE-60
NM 2/A-60/A,S-60/A,B-60/A
NM 3/AE-60,BE-60,CE-60
B-NM 20/160AE-60,BE-60 NM 20/160AE-60,BE-60
B- NM 25/12A-60/A,B-60/A NM 25/12A-60/A,B-60/A
B-NM 25/160AE-60,BE-60 NM 25/160AE-60,BE-60
NM 25/20BE-60
NM 25/20AE-60,SE-60
B-NM 25/200BE-60
B-NM 25/200AE-60,-SE-60
NM 10/SE-60,AE-60,DE-60,FE-60
NM 11/AE-60,BE-60
NM 12/DE-60
NM 12/AE-60,CE-60
B-NM 17/FE-60,GE-60,HE-60 NM 17/FE-60,GE-60,HE-60
B-NM 17/DE-60
NM 17/DE-60

DN2
ISO 228

h1

h2

h3

m1

m2

n1

n2

n3

l1

l2

G1
G1
G1
G 11/4
G 11/2
G 11/2

G1
G1
G1
G 3/4
G1
G1

40
45
50
53
56
56

80
95
112
100
90
100

132
150
180
150
140
160

176
207
240
228
199
228

40
32
40
32
55
43
37,5 27,5
37,5 27,5
37,5 27,5

170
190
245
190
170
190

140
160
205
150
130
150

9,5
9,5
11,5
9,5
9,5
9,5

77
87
110
102
85
102

81
90
113
102
88
102

G1

63

125

180

253

45

32,5

245

200

45

11,5

125

125

G 11/2

G1

63

125

180

253

45

32,5

245

200

45

11,5

125

125

G2
G2

G 11/4
G 11/4

63
70

100
112

150
170

228
240

50
50

35
35

190
210

140
160

50
50

13
15

90
103

97
110

G2

G 11/4

70

132

190

260

50

35

240

190

50

15

125

127

G 21/2

G 21/2

80

112

160

240

50

35

210

160

17
17
37
30
9
30
49
42
49
42
30
37
47
45
37
20

35
35
45
38
38
38

G 11/2

261
305
375
375
313
380
393
460
405
460
382
400
400
470
417
480

50

14

96

113

171
218
244
246
195
246
251
295
263
295
239
247
247
300
257
295

15

g1
10
10
12
10
10
10
11
11
14
14
14
14

NMD

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Dimensions and weights


NMD 20/140
NMD 25/190

NMD 20/110

f
l1

l2

325

4.93.179

36
46
8.5

4.93.005

17

9.5

38
130
170

188

m2

n3

B- NMD 20/110B-60/A
B- NMD 20/110Z-60/A
B- NMD 20/110A-60/A

NMDM
kg

NMD
kg

B-NMD
kg

13
14
15,1

12,1
13
14,2

13,4
14,2
17,4

n1

TYPE
BBBBB-

NMD 20/140BE-60
NMD 20/140AE-60
NMD 25/190CE-60
NMD 25/190BE-60
NMD 25/190AE-60

NMDM
kg

NMD
kg

B-NMD
kg

23,9
25,2

22,7
24,8
39
46,7
51

25,2
27,6
42,7
51
55

mm

DN1

DN2
ISO 228

NMD

B-NMD
B- NMD 20/140AE-60,BE-60
B- NMD 25/190CE-60
B- NMD 25/190BE-60
B- NMD 25/190AE-60

NMD 20/140AE-60,BE-60
NMD 25/190CE-60
NMD 25/190BE-60
NMD 25/190AE-60

n2

m1
w

TYPE

h1

h3

g1

10
95

DN1

204

132

G 1 1/4

G1

DN2

DN2

93

h2

93
G1

75

h1

h2

h3

m1

m2

n1

n2

n3

l1

l2

g1

G 11/4

G1

80

112

152

243

75

55

200

160

9,5

110

110

97

140

180

268

100

70

240

190

50

14

133

133

256
274
306
306

10

G1

37
50
49
49

38

G 11/2

417
447
500
500

13

NMD 32/210
NMD 40/180
f
a

l1

l2
DN2

DN2

DN1

h2

TYPE

h3
g1

h1

s
m2

n1

m1

B - NMD
B-NMD 32/210DE-60
B-NMD 32/210BE-60,CE-60
B-NMD 32/210AE-60
B-NMD 40/180DE-60
B-NMD 40/180BE-60,CE-60
B-NMD 40/180AE-60

NMD
NMD 32/210DE-60
NMD 32/210BE-60,CE-60
NMD 32/210AE-60
NMD 40/180DE-60
NMD 40/180BE-60,CE-60
NMD 40/180AE-60

g2

n2

DN1
DN2
ISO 228
G2

G 11/4

G2

G 11/2

B-NMD
kg

60
70
76,5
99
59
69
75,5
97

66
76
82
105
65
75
81
102

B- NMD 32/210DE-60
B- NMD 32/210CE-60
B- NMD 32/210BE-60
B- NMD 32/210AE-60
B- NMD 40/180DE-60
B- NMD 40/180CE-60
B- NMD 40/180BE-60
B- NMD 40/180AE-60

4.93.077

NMD
kg

mm
a

530
110 550
625
535
121 555
630

n1

n2

155
283 205 175 194
150 215 310 280 250 258
170
355 298 268 286
155
283 205 175 194
150 215 310 280 250 258
170
355 298 268 286

h1

h2

140
190
216
140
190
216

16

h3

m1

m2

z
15

15

54
68
70
54
68
70

10
12
12
10
12
12

l1

l2

139
150 150 108
152
133
145 145 102
145

g1

g2

38
38
38
38

6
6
-

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Construction
Close-coupled centrifugal pumps; electric motor with extended
shaft directly connected to the pump.
Pump casing with axial suction and radial delivery on top,
main dimensions and performance according to EN 733.
The pumps in bronze are supplied fully painted.
Connections: Flanges according to PN 10, EN 1092-2.
Counter-flanges (on request)
Sizes
Flanges
from NM 32/... to NM 50/...
Screwed flanges EN 1092-1, PN 16
from NM 65/... to NM 100/250 Flanges for welding
EN 1092-1, PN 10

Applications
- For clean liquids without abrasives, which are non-aggressive
for the pump materials (solids content up to 0.2%).
- For water supply.
- For heating, air conditioning, cooling and circulation plants.
- For civil and industrial applications.
- For fire fighting applications. - For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.

Motor

Materials
Components
Pump casing
Lantern bracket
Impeller

NM

2-pole induction motor, 60 Hz (n = 3450 rpm).


NM: three-phase 220/380 V, 380/660 V.
Insulation class F.
Protection IP 54.
Constructed in accordance with IEC 60034.

B-NM

Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
for NM 32/12-16-20, NM 40/20
B-NM 32/125-160-200, B-NM 40/200
Cr Ni steel
AISI 303 up to 2.2 kW
Cr Ni Mo steel
AISI 316
Cr steel AISI 430
from 3 kW to 75 kW
Carbon - Ceramic - NBR
Steel Fe 430B UNI 7070

Shaft

Mechanical seal
Counter-flanges

Special features on request


- Other voltages. - Protection IP 55.
- Bronze impeller. - Special mechanical seal.
- Packed gland (only for NM standard construction).
- Single-phase motor (NMM) up to 1.5 kW.
- Explosion proof construction in accordance with Directive
94/9 EEC (ATEX).
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


30
20

40
30

50
40

U.S. g.p.m.
50

100

Imp. g.p.m.

200
100

300
200

400
300

500
400

1000
500

2000
1000

130

400

100

NM

300

H
m

NM 40/25

NM 50/25

NM 32/20

NM 40/20

NM 50/20

NM 32/16

NM 40/16

NM 50/16

50
40

NM 65/250

NM 80/250

NM 100/250

200

NM
50M

ft

NM
80/200

NM 65/200

NM 100/200

30

NM 65/16
20
NM 32/12

NM 40/12

100
90
80
70

NM 80/16

NM
65/12

NM 50/12

60
50
40

10

30

20
5
5

6
100

9 10
150

m 3/h

Q l/min

20
300

30
400

500

40

50

200

100
1000

2000

3000

300
4000 5000

400

500
8000
72.824.C

17

NM

60 Hz

Close Coupled Centrifugal Pumps


with flanged connections

Performance n 3450 rpm


B-NM

B-NM 32/12F-60
B-NM 32/12D-60
B-NM 32/12A-60
B-NM 32/12S-60
B-NM 32/16B-60
B-NM 32/16A-60
B-NM 32/20D-60
B-NM 32/20C-60
B-NM 32/20A-60

B-NM

B-NM 40/12F-60
B-NM 40/12C-60
B-NM 40/12A-60
B-NM 40/16C-60
B-NM 40/16B-60
B-NM 40/16A-60
B-NM 40/20C-60
B-NM 40/200B-60/A
B-NM 40/200A-60/A
B-NM 4025/C-60/A
B-NM 4025/B-60/A
B-NM 4025/A-60/A

B-NM

B-NM 50/12F-60
B-NM 50/12D-60
B-NM 50/12A-60
B-NM 50/160B-60/A
B-NM 50/160A-60/A
B-NM 50/200B-60/A
B-NM 50/200A-60/A
B-NM 5025/C-60/A
B-NM 5025/B-60/A
B-NM 5025/A-60/A
B-NM 5025/65EE-60
B-NM 5025/65DE-60
B-NM 5025/65CE-60

B-NM

B-NM 65/125CE-60
B-NM 65/125AE-60
B-NM 65/160EE-60
B-NM 65/160DE-60
B-NM 65/160CE-60
B-NM 65/160BE-60
B-NM 65/160AE-60
B-NM 65/200CE-60
B-NM 65/200BE-60
B-NM 65/200AE-60
B-NM 65/250CE-60
B-NM 65/250BE-60
B-NM 65/250AE-60

P2

NM

NM 32/12FE-60
NM 32/12DE-60
NM 32/12AE-60
NM 32/12SE-60
NM 32/16BE-60
NM 32/16AE-60
NM 32/20DE-60
NM 32/20CE-60
NM 32/20AE-60

kW

HP

0,55
0,75
1,1
1,5
1,5
2,2
2,2
3
4

0,75
1
1,5
2
2
3
3
4
5,5

NM 40/12F-60/A
NM 40/12C-60/A
NM 40/12A-60/A
NM 40/16C-60/A
NM 40/16B-60/A
NM 40/16A-60/A
NM 40/20C-60/A
NM 40/20B-60/A
NM 40/20AR-60/A
NM 40/20A-60/A
NM 40/25C-60/A
NM 40/25B-60/A
NM 40/25A-60/A

kW

HP

1,1
1,5
2,2
2,2
3
4
4
5,5
5,5
7,5
9,2
11
15

1,5
2
3
3
4
5,5
5,5
7,5
7,5
10
12,5
15
20

P2

NM

NM 50/12F-60/A
NM 50/12D-60/A
NM 50/12A-60/A
NM 50/16B-60/A
NM 50/16A-60/A
NM 50/20B-60/A
NM 50/20A-60/A
NM 50/25C-60/A
NM 50/25B-60/A
NM 50/25A-60/A
NM 50M/EE-60
NM 50M/DE-60
NM 50M/CE-60

kW

HP

2,2
3
4
5,5
7,5
9,2
11
11
15
18,5
11
15
18,5

3
4
5,5
7,5
10
12,5
15
15
20
25
15
20
25

P2

NM

NM 65/12EE-60
NM 65/12CE-60
NM 65/12AE-60
NM 65/16EE-60
NM 65/16DE-60
NM 65/16CE-60
NM 65/16BE-60
NM 65/16AE-60
NM 65/20CE-60
NM 65/20BE-60
NM 65/200AE-60
NM 65/250CE-60
NM 65/250BE-60
NM 65/250AE-60

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

l/min

110

125

140

160

180

200

220

250

280

315

350

400

450

500

14
19,5
24,5
26
31
36,5
39
45
57

13,5
19
24
26
30,5
36
38
44,5
56,5

13
19
24
25,5
30
35,5
37,5
44
56

12,5
18,5
23,5
25,5
29,5
35
36,9
43
55,5

12
18
23
25
29
34
35
42
55

11,5
17,5
22
24,5
28
33
34
41
54

10,5
16,5
21,5
24
27
32,5
32
40
53

9
15,5
20
22,5
25*
31*

21*
23*
29*

19*

16,5*

12,5*

37
51

34*
49*

15

16,8

18,9

21

24

27

30

33

37,8

39

42

45

48

54

650

700

750

800

900

25,6

23

H
m

Q
m3/h

P2

NM

Q
m3/h

kW

HP

4
5,5
7,5
5,5
7,5
9,2
11
15
15
18,5
22
22
30
37

5,5
7,5
10
7,5
10
12,5
15
20
20
25
30
30
40
50

l/min

H
m

250

280

315

350

400

450

500

550

630

15,4
18,5
22,5
25,5
31
37,1
44
52
56,5
59,5
65,4
71,5
90,4

14,9
18,1
22,3
25,1
30,6
36,9
43
51,5
56
59
65
71,3
90,2

14,3
17,6
21,9
24,4
30,3
36,5
42
50,5
55
58,5
64,4
70,8
89,7

13,4
17
21,4
23,6
29,6
36,1
41
49,5
54
58
63,5
70,3
89,1

11,8
15,8
20,6
22,1
28,5
35,2
39
47,5
52
56
61,5
68,9
88,5

10
14,2
19,6
20,1
27,1
34,3
36
44,5
49
53,5
58,6
66,4
87,3

7,8
12,4
18,3
17,8
25,4
33,2

5,6
10,5
16,7
15,4
23,2
31,8

6,9
13,7
10,6
19,2
28,8

40

35

50,5
54,2
63,3
86,1

47
49
59,2
83,8

12,9
18,1
27,9

38,5
50
78

76

Q
m3/h

24

27

30

33

37,8

42

48

54

60

66

69

72

75

84

l/min

400

450

500

550

630

700

800

900

1000

1100

1150

1200

1250

1400

16,1
19,4
24,8
35,3
42,7
50,4
57,3
60,3
73,2
86,9
47,5
58
69

15,4
19
24,6
34,9
41,6
49,8
56,9
59,3
72
86,2
47
57,5
68,5

14,2
18
24
33,6
41,2
48,5
55,7
57,2
70,1
84,7
46
56
67,5

13
17
23,4
32,4
40,3
47,1
54,6
55
68,1
83
45
55
66,5

11,1
15,5
22,3
30,1
38,5
44
52,2
50
64,3
79,8
42
53
64,5

8,6
13,5
20,8
27,5
36,3
40,5
49,5
44
59,3
76
38,5
50,5
62,5

5,8
11,1
19
24,5
33,8
36
46
36,5
52,8
72
34
47,5
60,5

8,4
17
20,9
30,9
30,2
41,8

16
19
29,4
27,3
39

14,8
17,1
27,8

13,6
15,1
26,1

20,4

36,2

33,2

43,8
66,9
29
44
57,5

26
42
56

24
40
54

20
36,5
51

25*
42*

42

48

54

60

66

75

84

96

108

120

132

150

168

2000

2200

2500

2800

13*
18*
22,5*
27*
31*
38,5*
45*

27*
35*
41*

H
m

51
57,6
61,9
74,6
87,6

50,6
57,7
61,2
73,9
87,3

Q
m3/h

37,8

l/min

630

700

800

900

1000

1100

1250

1400

1600

1800

19
23
27

18,5
22,5
26,5

18
22
26
20
26
30
33,5
37,5
44
49,5
56
64
79,5
90

17
21,5
25,5
19,5
25,5
29,5
33
37
43,5
49
55,5
63
79
89,5

16
21
25
19
25
29
32,5
37
43
48,5
55
62,5
78,5
89

15
19,5
24
18
24,5
28,5
32
36,5
42,5
48
54,5
61,5*
78*
88,5*

13*
17,5
22
17
23,5
27,5
31
36
41
47,5
54
60*
77*
87*

15*
19,5*
15
22
26,5
29,5
34,5
40
46,5
53,5
57,5*
75*
86*

13*
19,5*
24*
28*
33*
37,5*
44,5*
51*
54,5*
71*
83*

10*
16,5*
21*
25*
30*
35*
42*
48*
50*
66,5*
78,5*

H
m

18

NM

60 Hz

Close Coupled Centrifugal Pumps


with flanged connections

Performance n 3450 rpm


P2

NM

B-NM

B-NM 80/160EE-60
B-NM 80/160DE-60
B-NM 80/160CE-60
B-NM 80/160BE-60
B-NM 80/160AE-60

NM 80/16EE-60
NM 80/16DE-60
NM 80/16CE-60
NM 80/16BE-60
NM 80/16AE-60
NM 80/200BE-60
NM 80/200AE-60
NM 80/250EE-60
NM 80/250DE-60
NM 80/250CE-60
NM 80/250BE-60
NM 80/250AE-60
NM 100/200EE-60
NM 100/200DE-60
NM 100/200CE-60
NM 100/200BE-60
NM 100/200AE-60
NM 100/250BE-60
NM 100/250AE-60

kW

HP

7,5
9,2
11
15
18,5
22
30
22
30
37
45
55
18,5
22
30
37
45
55
75

10
12,5
15
20
25
30
40
30
40
50
60
75
25
30
40
50
60
75
100

NM Standard construction.
B-NM Bronze construction.

Q
m3/h

75

84

96

l/min

1250

1400

1600

19,5
23
27,5
34
38,5
46,5
56
51
65
73,5
84
94,5

19
22,5
27
33,5
38
46
55,5
50
64
73
83,5
94

18
22
25,5
33
37,5
45,5
55
48,5
62,5
72
82,5
93

H
m

108

120

132

150

168

180

192

210

240

270

300

1800

2000

2200

2500

2800

3000

3200

3500

4000

4500

5000

17,5*
21*
25*
32,5*
37*
44,5
54
46,5
61
70,5
81
92,5
30
36
45
54
61,5
73,5
90,5

16,5*
19,5*
24,5*
31,5*
36,5*
43,5*
53,5*
44,5*
59*
69*
80*
91,5*
29,5
35,5
44,5
53,5
61
73
90

15*
18*
23*
31*
36*
42*
52*
42*
56,5*
67*
78*
90*
29
35
44
53
60,5
72,5
90

13*
15*
20*
28*
33*
39*
49*
38*
53*
63*
74*
87,5*
28
34
43
52,5
60
71,5
89

16*
22,5*
28,5*
35*
46*
33*
49*
59*
70*
84*
27
33
42,5
51,5
59,5
70
88,5

18*
24*
32*
43*
29*
45*
55*
67*
80*
26*
32*
41*
50*
59*
69*
87,5*

41*
51*
62,5*
76,5*
24,5*
31*
40*
49*
58*
67*
87*

22,5*
29*
39*
47,5*
56*
65*
85*

19*
24*
34*
43*
52,5*
60*
81*

28*
38*
48*
55*
75*

42
48
67

P2 Rated motor power output.


H Total head in m.

Maximum suction lift 1-2 m.

With 1 m suction head.


Tolerances according to ISO 9906, annex A.

Rated currents
P2
kW
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
75

HP
0,75
1
1,5
2
3
4
5,5
7,5
10
12,5
15
20
25
30
40
50
60
75
100

220V / 380V Y
380V / 660V Y
IN A
IN A
IN A
4,5
2,6
4,5
2,6
5,7
3,3
9
5,2
10,7
6,2
13
7,5
11,3
6,5
14,5
8,4
18,2
10,5
21,5
12,4
25
14,4
32,5
18,5
40,7
23,5
50,5
29,1
65
37,5
82
47
97
56
119
68,5
157
90

IA/IN
5,2
5,2
5,3
6
5,9
9,5
9,8
8,2
9,5
8,2
8,1
8,8
9,7
9
9
8,5
8
7,2
6

P2
Rated motor power output.
IA/IN D.O.L. starting current / Rated current

19

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 3450 rpm


0 U.S. g.p.m. 20

40

60

0 Imp.g.p.m. 20

80

40

0 U.S. g.p.m. 20

100

60

0 Imp.g.p.m.

80

40

60

20

80

40

60

40

30

S 116

H
m

58 61

63

A 114

80

65%

NM 32/16

120

m
35

ft

D 103

20

NM 32/12
64

130

A 146

50

110

63
60

61

B 131

ft
100

53

58

F 88

30
54

40

90

55

10

57%

25
20

80
70

20

0
0

Q m /h 5
3

10

15

26

20

10

20

15

A
D

2.0

3
P
HP

P
kW
1.2

HP
0

3.5

2.4

P
kW

Q m /h
3

2
1.5

0.8

0
8
20
10
ft

Q m /h 5
3

0 U.S. g.p.m. 20
0

10

15

40

20

60

Imp.g.p.m. 20

80

40

72.514

0
26

100

60

NPSH
10
ft

Q m3/h

0 U.S. g.p.m.

10

50

25

80

H
40

45 47,5

20

NM 32/20
50

ft
150

C 164
D 153

40

150

80

NM 40/12

70

C 108

60

F 100

15

52%

50

0
20

200

H (m)

A 178

60

100
A 118

70

72.515

15

50
40

10

30

50

20

100

30

10
0

20
50
10
5

Q m /h
3

10

15

25

20

6
P
HP
4

4
P
kW

C
D

P (kW)

(%)

10

15

20

72.516

l/min

30

40

400

600

3
A

B
C

1
0

40

20

0
10
8

30

20

NPSH (m)

10

Q m3/h 5

20
200

20

NPSH

10

8
6
NPSH
4
m
2

Q m /h

60

2
1

2,4
2,0
1,6
1,2
0,8
0,4
0,0
80

0
0

P (HP)

20

6
NPSH
4
m
2

NPSH

ft

25

10
0
0

20

Q m3/h

10

20

30

72.517N

40

NPSH (ft)

6
NPSH
4
m
2

H (ft)

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 3450 rpm


50

100

40

150

NM 40/16

A 144

35

0 U.S. g.p.m. 40

200

B 132

30
C 121

H (m)

25
20
15
10
5
0
5

0
0

3
10
Q m /h
200
l/min

20

30
400

40

50
800

600

P (kW)

3
C

2
1
0
80

0 Imp.g.p.m.

80
40

160

80
50

A 178

60

120

200

NM 40/20

55

AR 174

57,5

H
B 168

120

ft

58%

50
55

C 160

150
57

50

40
54
100

30

6
5
4
3
2
1
0

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0

H (ft)

0 U.S. g.p.m.

P (HP)

45

Q m3/h

10

20

40

30

10
P
kW
6

12

A
AR

P
8

HP
4

(%)

60

2
0

20
6

12

10
2
0

Q m3/h 10

0 U.S. g.p.m.
100

20

30

50

100

A 218

90

72.518N

40

50

150

28

NM 40/25

300

B 198

200

72.519

30

200

40

40

90

NM 50/12

80
70

D 114

60
F 106

16

50

14

40

12

100

10

20

300

A 127

18

H (m)

50

H (ft)

30

20

0
10

20
200

l/min

30

40

400

600
A

14
B

10

20

16
12

24

2
60

P (kW)

Q m /h

P (HP)

0
0

0
0

Q m /h

20

30

40

400

l/min

50
800

60

1
0
80

6
5
4
3
2
1
0

80

70
1200

P (HP)

10

60

(%)

40
20

40

10
2
0

Q m /h

10

20

30

72.520N

40

NPSH (ft)

0
6

NPSH (m)

20
0
8

20

6
4

10
2
0

21

Q m3/h

20

30

40

50

60

70

72.521N

80

NPSH (ft)

H (m)

100

20

30

P (kW)

20

22

C 188

60

(%)

0 U.S. g.p.m.

10

26

70

NPSH (m)

Q m3/h

24

80

18

30
NPSH
20
ft
10

H (ft)

NPSH
8
m

NPSH (ft)

NPSH (m)

40

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 3450 rpm


300

NM 50/16

B 144

35
30

H (m)

25
20
15
10
5
0
10

0
0

Q m /h

l/min

20
30
400

40

50
800

60

70
1200

80

12
10
8
6
4
2
0

P (kW)

90

6
4
2
0
80

0 U.S. g.p.m.

100

200

300

A174

NM 50/20

B 164

50

150

40
H (ft)

40

60

100

30
20

50

10
0
14
12
10
8
6
4
2
0
80

0
0

Q m /h

20

30

40

400

l/min

50
800

60

70
1200

80

15

10
5

P (HP)

A 156

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0

H (m)

200

P (kW)

100

H (ft)

0 U.S. g.p.m.

P (HP)

45

(%)

(%)

(%)

70
60

60

10
2
0

90

Q m 3/h

U.S. g.p.m.

20

30

40

50

100

60

70

80 72.522N 90

200

4
10

2
0

Q m3/h

20

30

0 U.S. g.p.m. 100


0 Imp.g.p.m.

280

40

50

200

100

60

B 200

300

400

200

300

80

240

200

60

C 190

220
C 186

45

50

ft

55%

D 178

60

200
50

E 165

160

3
Q m /h
l/min

20

30

40

400

50
800

60

70

35
A
B

15

30
20

10

10

80
20
0
P (HP)

P (kW)

120

100
0
0

20

24

Q m3/h 20

40

60

100

80

32

28
P
HP
20

20

P
kW
12

0
70

(%)

40

40

120

60

16
12

50

40
8

10
20

6
4

10

Q m /h

20

30

40

50

60

72.524N

70

30
NPSH
25
ft
20

NPSH
8
m

NPSH (ft)

NPSH (m)

160

45

140
40

240

NM 50M

50

180

30

70 72.523N 80

260

70

H (m)

20

300

NM 50/25

A 216
80

40
8

NPSH (ft)

NPSH (ft)

20

NPSH (m)

40
8

H (ft)

NPSH (m)

50

15

22

Q m3/h 20

40

60

80

72.525

10

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 3450 rpm



0 U.S. g.p.m. 100


0 Imp.g.p.m. 100

200

 



 

 

200


300

400

300

 








m3/h 20

40

60














8
NPSH
6
m
4









   
  
  
  









m /h


















 




  


















  




 

 



D 



















25
20
NPSH
15
ft



m3/h



 

















 







 




m /h
3

 








D 







 

 







  



100

80






















D 










 








 












  












  

 


  

 



D 



 

  














m3/h

 




 































m3/h 















m /h
3









 




 




 

23











 





 




m /h
3
















NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 3450 rpm


0 U.S. g.p.m. 200
0 Imp.g.p.m. 200
40
A 155
H B 145
50
m
30

20

60

400
60 65
70

800

600

60

NM 80/16

120

65

ft
100

70

71
D 73%

D 133
E 125

60

50

m
40

80

B 217

80

80

120

400

600

400
55 60 65 68
70

600

800

1000
800

NM 80/250
D 73%

C 205
D 195

70

E 178

20
0 Q m3/h 40
60

68
80

120

40
P
kW
20
0
10
8
NPSH
6
m
4
2
0 Q m3/h 40

320
280
ft
240
200

120
160

200

A
B
C
D

80
240
80
60
P
40
HP
20
0

80

120

160

400
65 67.5

B 172

0
10
8
NPSH
6
m
4
2
0 Q m3/h 40

160

40

60

600

600

800

NM 80/200

70

D 72%

67.5

190
ft
150

100

80

120

30
NPSH
20
ft
10
200 72.532 240
24

70
200

160
A
B

30
P
20
kW
10

160

A 185

20
0 Q m3/h 40
40

30
NPSH
20
ft
10
72.530
200

400

30

40
200
160
32
A
28
P
HP
B
20
C
16
D
12
E
8

120

0 U.S. g.p.m. 200


0 Imp.g.p.m. 200

65

60

0 U.S. g.p.m. 200


0 Imp.g.p.m. 200
100
A 228
m
80

600

C 139

10
0 Q m3/h 40
24
20
P
kW
12
8
4
10
8
NPSH
6
m
4
2
0 Q m3/h 40

400

40
P
HP
20
0

80

120

160

30
NPSH
20
ft
10
72.531
200

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 3450 rpm


0 U.S. g.p.m.

400

0 Imp.g.p.m. 200

600

1000

800
600

400

0 U.S. g.p.m.

1200

800

0 Imp.g.p.m. 200
100

1000

70

60

A 187

60

65 68
70

NM 100/200

200

C 168
40

1200

NM 100/250

60

1000

300

65

ft

B 212

150

250

70

D 155
E 145

30

1000
800

80

70

73%

50 55

800
600

ft
72

600
400

90

B 180

50

A 229

400

100

66

60

66

200
67,5%

20

50
150

50
10

40
0

60

Q m3/h

100

200

300
80

0
100

Q m3/h

100

200

300

A
40
P
kW
20

B
D
E

80
P
60
kW
40

60
P
40
HP
20

120
P
HP

80

60
40

20

10

10
30
NPSH
25
ft
20

NPSH
8
m
6

15

4
0

Q m /h
3

100

200

72.533

30
NPSH
25
ft
20

NPSH
8
m

15

300

25

Q m /h
3

100

200

72.534

300

NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Dimensions and weights

f
l1

l2

DN2

l1

DN2

l2

DN2

DN2

h2
DN1

DN1

h2
h3
g1

h3
g1

h1

4.93.083.1

m2

n3

m1

m2

n2

n2

Flanges
EN 1092-2

mm
kg
DN1 DN2

h1

h2

h3

m1 m2

n1

n2

n3

g1

l1

l2

97 245 12

NM 32/12SE-60, AE-60, DE-60, FE-60 50

32

80 405 112 140 222 100 70 190 140 37

50

14

93

50

32

80 410 132 160 242 100 70 240 190 47

50

14

120 120 250 12

36-34

NM 32/20DE-60
NM 32/20CE-60
NM 32/20AE-60

50

32

410
270
62
80 475 160 180 288 100 70 240 190 60
475
288
60

50

14

250
140 140 295 12
295

39
49
52

NM 40/12A-60/A, C-60/A, F-60/A

65

40

80 410 112 140 222 100 70 210 160 37

50

14

100 113 250 12

31-29-27

65

40

410
242
47
80 475 132 160 260 100 70 240 190 45
475
260
45

50

14

27-25-24-24

250
119 119 295 12
295

36
45
49
55
72-65-65

65

495
288
60
40 100
160 180
100 70 265 212
525
320
49

50

14

295
12
140 140
320

NM 40/25B-60/A, C-60/A
NM 40/25A-60/A

65

640
40 100
180 225 365 125 95 320 250 50
690

65

14

175 175

NM 50/12F-60/A
NM 50/12D-60/A
NM 50/12A-60/A

65

430
242
47
50 100 495 132 160 260 100 70 240 190 45
495
260
45

50

14

250
121 137 295 12
295

38
47
51

NM 50/16A-60/A, B-60/A

65

50 100 525 160 180 320 100 70 265 212 49

50

14

127 141 320 14

70-64

NM 50/20A-60/A, B-60/A

65

50 100 640 160 200 345 100 70 265 212 40

50

14

140 153 410 15

106-100

NM 50/25C-60/A
NM 50/25B-60/A
NM 50/25A-60/A

65

645
50 100 695 180 225 365 125 95 320 250 50
720

65

14

415
175 175 465 15
465

126
132
147

NM 50M/EE-60
NM 50M/DE-60
NM 50M/CE-60

65

700
50 100 750 192 225 377 298 258 262 216
775

135
151
165

NM 65/12EE-60
NM 65/12AE-60, CE-60

80

65 100

NM 65/16DE-60, EE-60
NM 65/16BE-60, CE-60
NM 65/16AE-60

6*

116-110
133

69

12

175 175 239

495
288
60
125 95 280 212
160 180
320
49
525

65

14

134 156

80

525
320
49
65 100 640 160 200 345 125 95 280 212 40
690
345
40

65

14

320
150 172 410 15
460

75-70
106-100
121

NM 65/20CE-60
NM 65/20BE-60

80

65 100

690
180 225 365 125 95 320 250 50
715

65

14

155 175 460 15

127
139

NM 65/200AE-60

80

65 100 825 202 225 408 400 360 344 254

20

90

14

155 175 245 42

164

NM 65/250BE-60, CE-60
NM 65/250AE-60

80

65 100

825 202
408 400 360 344 254
250
945 245
- 475 425 408 318

20
25

90
90

14
245 42
175 190
18 290
263 45

NM
NM
NM
NM

100

80 125

545
340
60
670
365
50
180 225
125 95 320 250
720
365
50
745
365
50

65

14

165 193

320
415
15
465
465

83
113-108
130
144

170 194 245 42

194-173

80/16EE-60
80/16CE-60, DE-60
80/16BE-60
80/16AE-60

410
15
460

20

NM 80/200AE-60, BE-60

NM 32/16AE-60, BE-60

NM 40/20C-60/A
NM 40/20A-60/A, AR-60/A, B-60/A

g1*

n1

NM

NM 40/16C-60/A
NM 40/16B-60/A
NM 40/16A-60/A

m1

n1

Picture

h1

4.93.082

295
15
320

55
73-67

195-174
299

100

80 125 850 202 250 408 400 360 344 254

20

90

14

NM 80/250DE-60, EE-60
NM 80/250AE-60, BE-60, CE-60

100

850 202
408 400 360 344 254
80 125
280
970 245
- 475 425 408 318

20
25

90
90

14
245 42
191 210
18 290
263 45

203-182
377-361-331

NM 100/200EE-60
NM 100/200CE-60, DE-60
NM 100/200AE-60, BE-60

800 192
377 298 258 262 216
125 100 125 850 202 280 408 400 360 344 254
970 245
- 475 425 408 318

20
20
25

69
90
90

12
239 6*
14
- 180 212 245 42
18 290
263 45

173
195-174
355-323

NM 100/250BE-60
NM 100/250AE-60

125 100 140

25

90
290
263 45
18
205 233
104
330
305 50

980 245
280
1050 275

475 425 408 318


480 430 460 356

Pumps with packed gland, dimensions available on request.

26

386
478

g2

DN
K
D

4.93.094

mm

Holes

DN

g2

32

76 100 140

19

18

40

84 110 150

19

18

50

99 125 165

19

20

65 118 145 185

19

20

80 132 160 200

19

22

100 156 180 220

19

24

125 184 210 250

19

24

B-NM

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Dimensions and weights

2
3

l1

l2

l1

DN2

DN2

DN2

DN2

l2

h2
DN1

DN1

h2
h3

h3

g1 h1

g1 h1

4.93.099

4.93.078

m2

n3

m1

b
w

n2

m2

n1

n1

Flanges
mm
Picture

B-NM 32/12S-60, A-60


B-NM 32/12D-60, F-60

50

B-NM 32/16B-60
B-NM 32/16A-60

50

B-NM 32/20D-60
B-NM 32/20C-60
B-NM 32/20A-60
B-NM 40/12F-60
B-NM 40/12A-60, C-60

50

h1

h2

h3 m1 m2 n1

n2

n3

l1

l2

g1

B-NM

32

80 405 112 140 222 100 70 190 140 37

50

14

93

97 245 12

33-32
31-29

32

80 410 132 160 242 100 70 240 190 47

50

14

120 120 250 12

44
45

32

410
270
45
80 475 160 180 288 100 70 240 190 60
475
288
60

250
140 140 295 12
295

49
57
61

100 113 250 12

33
37-35

14

250
119 119 295 12
295

45
53
57

295
140 140
12
375

63
80-74
130-124
147

50

14

40

80 410 112 140 222 100 70 210 160 37

65

40

410
242
47
80 475 132 160 260 100 70 240 190 45
475
260
45

B-NM 40/20C-60
B-NM 40/200A-60/A, B-60/A

65

495
288
60
40 100
160 180
100 70 265 212
580
320
49

B-NM 4025/B-60/A, C-60/A


B-NM 4025/A-60/A

65

40 100

B-NM 50/12F-60
B-NM 50/12D-60
B-NM 50/12A-60

65

430
242
47
50 100 495 132 160 260 100 70 240 190 45
495
260
45

B-NM 50/160A-60/A, B-60/A

65

50 100 580 160 180 320 100 70 265 212 49

50

14

B-NM 50/200A-60/A, B-60/A

65

50 100 695 192 200 377 298 258 262 216

20

69

12

B-NM 5025/C-60/A
B-NM 5025/B-60/A
B-NM 5025/A-60/A

65

635
50 100 685 192 225 377 298 258 262 216
710

20

69

12

B-NM 5025/65EE-60
B-NM 5025/65DE-60
B-NM 5025/65CE-60

65

635
50 100 685 192 225 377 298 258 262 216
710

20

69

B-NM 65/125AE-60, CE-60

65

B-NM 40/16C-60
B-NM 40/16B-60
B-NM 40/16A-60
3

65

635
192 225 377 298 258 262 216
685

80

65 100 580 160 180 320 125 95 280 212 49

B-NM 65/160DE-60, EE-60


B-NM 65/160CE-60

80

575
320
49
65 100
160 200
125 95 280 212
660
345
40

B-NM 65/160BE-60
B-NM 65/160AE-60

80

65 100

695
192 200 377 298 258 262 216
745

B-NM 65/200CE-60
B-NM 65/200BE-60
B-NM 65/200AE-60

80

B-NM 65/250BE-60, CE-60


NM 65/250BE-60
B-NM 65/250AE-60

50

50

14

g2

DN
K
D

4.93.094

mm

Holes

DN

g2

32

76 100 140

19

18

40

84 110 150

19

18

50

99 125 165

19

20

65 118 145 185

19

20

50

14

20

69

12

175 175 174

250
121 137 295 12
295

49
58
63

127 141 375 14

80-74

80 132 160 200

19

22

140 153 234

128-121

100 156 180 220

19

24

19

24

175 175 174

135
144
155

125 184 210 250

12

175 175 174

135
144
155

14

134 156 375 15

93-72
83-78
108
149
166

50

14

65

14

20

69

12

150 172 234

750 192
377 298 258 262 216
65 100 775 192 225 377 298 258 262 216
825 202
408 400 360 344 254

20

69
69
90

12
12
14

239 6
155 175 239 6
245 42*

80

825 202
408 400 360 344 254
65 100 840 222 250 - 387 347 369 279
945 245
- 475 425 408 318

20
20
25

90
90
90

14 245 42*
14 270 175 190 258 42*
18 290
263 45*

B-NM 80/160EE-60
B-NM 80/160DE-60

100

605
340
60
80 125
180 225
125 95 320 250
685
365
50

65

14

375
15
165 193
430

108
116

B-NM 80/160CE-60
B-NM 80/160BE-60
B-NM 80/160AE-60

100

725
80 125 775 192 225 377 298 258 262 216
800

20

69

12

165 193 239

155
163
166

375
150 172
15
430

EN 1092-2

kg

B- NM
DN1 DN2

g1*

n2

m1

27

157
177
179
210-189
350

NM4

60 Hz

Close Coupled Centrifugal Pumps


Construction
Close-coupled centrifugal pumps; electric motor with extended
shaft directly connected to the pump. Pump casing with axial
suction and radial delivery on top, main dimensions and performance according to EN 733 with additional sizes for completion.
The pumps in bronze are supplied fully painted.
Connections
Sizes
Connections
NM4 25/125, 25/160, 25/200
Threaded ports ISO 228
from NM4 32/16 to NM4 150/400 Flanges according to PN 10, EN 1092-2

Counter-flanges (on request)


Sizes
Flanges
from NM4 32/16 to NM4 50/25. Screwed flanges EN 1092-1, PN 16
from NM4 32/16 to NM4 150/400 Flanges for welding EN 1092-1, PN 10

Applications
- For clean liquids without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
- For water supply.
- For heating, air conditioning, cooling and circulation plants.
- For civil and industrial applications.
- When low noise operating is required.
- For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.

Materiali
Components
Pump casing
Lantern bracket
Impeller

NM4
Cast iron
GJL 200 EN 1561

B-NM4
Bronze
G-Cu Sn 10 EN 1982

Motor
4-pole induction motor, 60 Hz (n = 1750 rpm).
NM4: three-phase 220/380 V, 380/660 V.
Insulation class F.
Protection IP 54.
Constructed in accordance with IEC 60034.

Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
For NM4 25/125 - 25/160 - 25/200
NM4 32/16 - 32/20 - 40/20
Cr Ni steel
AISI 303 up to 1,1 kW
Cr Ni Mo steel
AISI 316
Cr steel AISI 430
from 1,5 kW to 75 kW
Carbon - Ceramic - NBR
Steel Fe 430B UNI 7070

Shaft

Mechanical seal
Counter-flanges

Special features on request


- Other voltages. - Protection IP 55.
- Bronze impeller.
- Special mechanical seal.
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 1750 rpm


10 U.S. g.p.m. 20

30

10 Imp. g.p.m. 20

40
30

50
40

100
50

200
100

300
200

400 500
300

1000

400 500

2000

1000

3000

2000

70
200

NM4

50

NM4 80/400
NM4 100/400 NM4 125/400

40

ft
NM4 150/400

30

NM4 80/315

NM4 65/31

100
NM4 100/315
NM4 125/315

20

NM4 40/25

NM4 50/25

NM4 65/25

NM4 150/315

NM4 80/25

50

NM4 100/25

NM4 25/200
NM4 32/20

10

NM4 50/20

NM4 40/20

40
NM4 65/20

NM4 125/250
NM4 80/20

NM4 25/160

30
NM4 100/20

NM4 32/16

NM4 50/16

NM4 40/16

NM4 65/16

20
NM4 80/16

NM4 25/125

4
10

2
1.5

m3/h 3
Q l/min
30
50

6 7 8 9 10

80 100

150

20
300

30
400 500

40

50

100
1000

2000

200

300

3000 4000 5000

400 500

7
700

10000
72.822.C

29

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Performance n 1750 rpm

B - NM4

kW
B- NM4 25/160BE-60
B- NM4 25/160AE-60
B- NM4 25/200CE-60
B- NM4 25/200BE-60
B- NM4 25/200AE-60

B - NM4
B-NM4 32/16B-60
B-NM4 32/16A-60
B-NM4 32/20B-60
B-NM4 32/20A-60
B-NM4 40/16C-60
B-NM4 40/16B-60
B-NM4 40/16A-60
B-NM4 40/20B-60
B-NM4 40/20A-60
B-NM4 4025/C-60/A
B-NM4 4025/B-60/A
B-NM4 4025/A-60/A

B - NM4
B-NM4 50/16B-60
B-NM4 50/16A-60

B-NM4 5025/C-60/A
B-NM4 5025/B-60/A
B-NM4 5025/A-60/A
B-NM4 65/16C-60
B-NM4 65/16B-60
B-NM4 65/16A-60

NM4 25/12A-60/A
NM4 25/160BE-60
NM4 25/160AE-60
NM4 25/200CE-60
NM4 25/200BE-60
NM4 25/200AE-60

1,5

1,89

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16

20

25

31,5

40

50

60

70

80

90

100

110

125

140

160

180

200

220

250

24

27

30

P2

Q
m3/h

2,4

3,6

4,2

4,8

5,4

l/min

40

50

60

70

80

90

kW

HP

0,37
0,37
0,55
0,75
0,37
0,55
0,75
1,1
1,1
1,5
2,2
3

0,5
0,5
0,75
1
0,5
0,75
1
1,5
1,5
2
3
4

P2
kW

HP

1,1
1,1
1,1
1,5
2,2
2,2
3
4
1,1
1,1
1,5
2,2
3
4
5,5
5,5
7,5
9,2

1,5
1,5
1,5
2
3
3
4
5,5
1,5
1,5
2
3
4
5,5
7,5
7,5
10
12,5

P2

NM4
NM4 80/16CE-60
NM4 80/16BE-60
NM4 80/16AE-60
NM4 80/20CE-60
NM4 80/20BE-60
NM4 80/20AE-60
NM4 80/25CE-60
NM4 80/25BE-60
NM4 80/25AE-60
NM4 80/31CE-60
NM4 80/315BE-60
NM4 80/315AE-60
NM4 80/400CE-60
NM4 80/400BE-60
NM4 80/400AE-60

l/min

1,2

H
m

NM4
NM4 50/16B-60/A
NM4 50/16A-60/A
NM4 50/20C-60/A
NM4 50/20B-60/A
NM4 50/20A-60/A
NM4 50/25C-60/A
NM4 50/25B-60/A
NM4 50/25A-60/A
NM4 65/16CE-60
NM4 65/16BE-60
NM4 65/16AE-60
NM4 65/20BE-60
NM4 65/20AE-60
NM4 65/25BE-60
NM4 65/25AE-60
NM4 65/31CE-60
NM4 65/31BE-60
NM4 65/31AE-60

HP

0,25 0,34
0,37 0,5
0,37 0,5
0,37 0,5
0,55 0,75
0,75
1

NM4
NM4 32/16BE-60
NM4 32/16AE-60
NM4 32/20BE-60
NM4 32/20AE-60
NM4 40/16C-60/A
NM4 40/16B-60/A
NM4 40/16A-60/A
NM4 40/20BE-60
NM4 40/20AE-60
NM4 40/25C-60/A
NM4 40/25B-60/A
NM4 40/25A-60/A

Q
m3/h

P2

NM4

kW

HP

1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
9,2
11
15
18,5
22
30

1,5
2
3
3
4
5,5
5,5
7,5
10
12,5
15
20
25
30
40

H
m

6,25 6,2 6,1 6,1


6
5,7 5,4
5
4,6 4,1 3,6
7,95 7,9 7,85 7,8 7,7 7,5 7,2 6,9 6,5 5,8
5
9,9 9,9 9,8 9,75 9,7 9,4 9,3
9
8,5
8
7,2 6,5
12,4 12,3 12,2 12 11,8 11,5 11,2 10,8 10,4 9,8
9
8
6
4*
15,5 15,5 15,4 15,2 15 14,7 14,5 14 13,5 13 12,4 11,6 9,8 7,5*
18,3 18,3 18,3 18,3 18,2 18,1 18 17,7 17,4 17 16,5 15,3 13,9* 11*

12

13,2

l/min

180

200

9
10,55
11,2
12,8
16,7
18,9
23,1
24,1

9
10,6
11,2
12,8
16,8
18,9
23,1
24,1

15

16,8 18,9

220

250

280

9
10,6
11,1
12,8
16,9
18,9
23,1
24,1

8,95
10,6
11
12,75
16,9
18,8
23
24

8,8
10,6
10,8
12,6
16,9
18,5
22,8
23,8

8,4

6,6
8,3
11,4
13,6
6,65
8
9,65
13,1
15,1
18,1
22,7
25

6,1
7,8
10,8
13,2
6,53
7,95
9,6
13
15
18
22,6
24,9

21

24

27

315

350

400

8,55
10,5
10,4
12,3
16,8
18,2
22,6
23,6

8,25
10,3
10
11,9
16,6
17,8
22,2
23,2
6,6
7,9
9,3
12,5
14,5
19
23,2
27
32
36

7,7
9,9
9,1
11,3
16,3
17,1
21,5
22,6
6,6
7,8
9,3
12,4
14,4
19
23,1
27
32
36

60

66

H
m

9,6 10,8

12

13,2

15

16,8 18,9

21

100 125 140 160 180 200 220 250 280 315 350 400 450 500

7,6 7,6 7,5 7,4 7,4 7,3 7,1


9,2 9,2 9,1 9,1
9
9
8,8
13,1 13 12,9 12,8 12,6 12,4 12,2
14,9 14,8 14,7 14,6 14,5 14,3 14,1
6,75 6,75
8,1 8,1
9,7 9,7
13,3 13,2
15,3 15,2
18,3 18,2
22,7 22,7
25,1 25

Q
10,8
m3/h

7,5

5,3
7,2
9,8
12,4
6,35
7,8
9,5
12,7
14,7
17,9
22,6
24,9

4,4
6,4
8,7
11,4
6,15
7,6
9,37
12,5
14,5
17,6
22,5
24,8

5,4*
7,3*
10*
5,9
7,4
9,2
12
14
17,3
22,3
24,6

30

33

450

500

7
9,3
8
10,5
15,74
16,2
20,5
21,9
6,5
7,7
9,2
12,3
14,3
18,8
23
26,5
31,5
35,5

6,25
8,6
6,8
9,4
15,2
15,1
19,5
21
6,4
7,7
9,2
12,2
14,2
18,7
23
26
31
35

75

84

5,7*
8,5*
5,53
7,2
9
11,5
13,7
16,8
22,1
24,4

4,9
6,75
8,7
10,5
13
15,7
21,6
24

4,2
6,25
8,3
9,5
12,2
14,2
20,6
23,6

3,2
5,5
7,8
7,8
10,8
11,8
19,2
22,6

4,6
7

5,8

9,3
8,9 4,4
17,5 14,2 10,1
21,3 18,5 15 10,7*

37,8

42

48

54

60

66

75

84

550

630

700

800

900 1000 1100 1250 1400

5,4
7,9
5,3
8,1
14,4
13,3
18,2
19,7
6,3
7,5
9,1
12,1
14,1
18,6
22,8
26
31
35

3,8*
6,6*
2,7
5,8
13
10,3
15,3
17
6
7,2
8,9
11,7
13,9
18,3
22,6
25,5
30,5
34,5

3,4
11,2
7,2*
12*
14*
5,7
7
8,6
11,4
13,6
18
22,4
25
30
34

8,5

5,4

5,2
6,5
8,1
10,8
13,1
17,5
21,8
24,5
29,5
33,5

4,5 3,7
5,8
5
4,1*
7,5 6,8
6* 4,5*
10
9,2 8,3* 6,6*
12,5 11,8 11* 9,5* 8*
16,8 15,6 14,2* 11,8* 9*
21,2 20,4 19,2* 17* 14*
23,5 22 20* 17* 13*
29
28 26,5* 24* 20,5*
33
32 31* 29* 26,5*

96

108

120

132

150

5,3*

Q
m3/h

30

33

37,8

42

48

54

l/min

500

550

630

700

800

900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500

H
m

5,3
6,6
8,6
10,9
12,5
14,2
17,4
20,8
24,2
28,5
32,5
37,5
49,5
56,5
63,5

5,2
6,5
8,5
10,8
12,5
14,1
17,3
20,8
24,2
28,5
32,5
37,5
49,5
56,5
63,5

5,1
6,4
8,4
10,7
12,4
14
17,1
20,7
24,1
28,5
32,5
37,5
49
56
63

5
6,3
8,3
10,6
12,3
14
17
20,7
24
28
32
37
49
55,5
63

4,9
6,1
8,1
10,5
12,1
13,9
16,6
20,5
24
27,5
32
37
48
55
62,5

4,5
5,9
7,9
10,3
12
13,8
16,1
20,1
23,9
27,5
31,5
36,5
47
54,5
62

30

4,1
5,5
7,6
10
11,7
13,5
15,8
19,8
23,4
27
31,5
36,5
46
53
61

3,8
5,2
7,3
9,7
11,4
13,4
15,2
19,4
23
27
31
36
44
52
60

3
4,6
6,9
9,1
10,6
12,8
14,1
18,3
22
26
30,5
35,5
41
49,5
58

3,7
6,1 4,5
8,2 6,7
9,8 8,5 6,5*
12
11 9,2* 7,4*
13 11,3 9,5*
17,3 15,7 13,8* 11,5*
21,1 19,4 17,5* 15,2* 12,7*
25
23 21* 18*
29,5 28 25,5* 23* 21*
35
33 31,5* 29,5* 27*
37,5 32 25*
47
41 35* 27*
55,5 52 46* 40* 33,5*

168

180

192

210

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Performance n 1750 rpm

P2

NM4
NM4 100/20CE-60
NM4 100/20BE-60
NM4 100/20AE-60
NM4 100/25BE-60
NM4 100/25AE-60
NM4 100/315CE-60
NM4 100/315BE-60
NM4 100/315AE-60
NM4 100/400CE-60
NM4 100/400BE-60
NM4 100/400AE-60

kW

HP

3
4
5,5
7,5
9,2
11
15
18,5
22
30
37

4
5,5
7,5
10
12,5
15
20
25
30
40
50

NM4 125/25EE-60
NM4 125/25DE-60
NM4 125/25CE-60
NM4 125/250BE-60
NM4 125/250AE-60
NM4 125/315CE-60
NM4 125/315BE-60
NM4 125/315AE-60
NM4 125/400CE-60
NM4 125/400BE-60
NM4 125/400AE-60
NM4 150/315DE-60
NM4 150/315CE-60
NM4 150/315BE-60
NM4 150/315AE-60
NM4 150/400CE-60
NM4 150/400BE-60
NM4 150/400AE-60

kW

HP

5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
18,5
22
30
37
45
55
75

7,5
10
12,5
15
20
25
30
40
50
60
75
25
30
40
50
60
75
100

NM4 Standard construction.


B-NM4 Bronze construction.

48

54

l/min

800

900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500

H
m

9,4
11,7
14
19,4
22,4
28
32,5
38,5
43
51,5
59,5

9,4
11,7
14
19,4
22,4
28
32,5
38,5
42,8
51,3
59,3

9,2
11,6
13,9
19,3
22,2
27,9
32,4
38,3
42,5
51
59

9,1
11,5
13,9
19,2
22,1
27,9
32,3
38,3
42,5
50,8
58,8

8,9
11,4
13,8
19
21,9
27,5
32
38
42
50,5
58,5

8,5
8
7,2 6,4 5,5
4*
11,2 10,8 10
9,2 8,3 6,5* 4,6*
13,7 13,3 12,7 12 11,3 9,8* 8,2* 7*
18,6 18 17,4 16,5 15,5 13,8* 11,5* 10*
21,4 21 20,4 19,6 18,8 17* 15* 13,3*
27
26
25 23,5 22 19,5* 15,5* 13*
31,5 31 30,5 29,5 28,5 26* 22,5* 20*
37,9 37,5 37
36
35 32,5* 30* 28*
42
41
40 38,5 37 34* 30,5* 28*
50,3 50
49
48
46 44* 41* 39*
58,3 58 57,7 57
56 53,5* 51* 49*

84

96

108

120

132

150

Q
m3/h

P2

NM4

Q
m3/h

60

66

75

84

96

168

108

180

120

192

132

210

240

168

270

180

300

192

210

5,5*
8,2*
11,6*
10*
17,5*
26*

13,5*
21*

37*
47*

33*
44*

330

360

240

270

300

330

5,5*
8,8*

390

420

450

480

l/min 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

H
m

11,2
14
16,8
19,4
23
28
32
37
45,5
51,7
59,5

11
13,9
16,6
19,2
22,9
27,8
31,7
36,7
45
51,5
59,3

10,7
13,7
16,4
19
22,8
27,5
31,5
36,5
44,8
51,3
59

10,4
13,4
16,1
18,8
22,7
27,3
31
36
44,6
51
58,8

10
13
15,8
18,6
22,5
27
30,8
35,8
44,5
50,7
58,7
22,8
25,8
30,5
35,6
45,5
51
59

9,4
12,4
15,2
18
22
26,5
30,5
35,5
44,3
50
58
22,6
25,6
30,4
35,5
45
50,5
58,5

8,5
11,6
14,6
17,4
21,5
25,5
29,5
35
43,5
49,5
57,5
22,3
25,4
30,2
35,4
44,5
50
58,3

8
11
14
17
20,9
25
29
34,5
43
49
57
22
25,2
30,1
35,3
44
49,5
58

P2 Rated motor power output.


H Total head in m.

7,3
10,4
13,3
16,3
20,3
24
28,5
34
42
48
56,5
21,8
24,9
30
35,2
43,8
49,3
57,8

6,2
9,3
12,3
15,2
19,2
23
27
32,5
40
46,5
55,5
21,2
24,4
29,8
35
43,5
49
57,5

Rated currents
220 V / 380 V Y

P2

150

380 V / 660 V Y

P2

kW

HP

IN A

IN A

IA/IN

kW

HP

IN A

IN A

IA/IN

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3

0,34
0,5
0,75
1
1,5
2
3
4

1,7
2
3,1
4
6
7,3
10,4
13,1

1
1,1
1,8
2,3
3,5
4,2
6
7,6

3,5
4,1
4,5
5
4,7
5,9
6,8
9,5

4
5,5
7,5
9,2

5,5
7,5
10
12,5

10,2
14,9
19
22,8

5,9
8,6
11
13,2

9,8
8
9,9
9,8

11
15
18,5
22
30
37
45
55
75

15
20
25
30
40
50
60
75
100

28
34,8
42
49,6
64,5
84
95,5
120
166

16,2
20,1
24,2
28,5
37,2
48,5
55
69
95,5

7,2
7
7,3
7,5
7,5
6
6,4
7,3
6

Rated motor power output.


P2
IA/IN D.O.L. starting current / Rated current

31

7,3*
10,3*
13,2*
17,2*
20*
25*
30,5*
36,5*
43,5*
53*
20
23,2
29
34,4
42
48
57

5*
8*
10,8*
14,9*
17*
22*
28*
32,5*
40*
50*
18,5
21,9
27,9
33,7
40,5
46,5
55,5

5,4*
8*
12,2*
13*
18,5*
25*
28*
35,5*
46*
16,7
20,2
26,5
32,5
38,5
44,5
54

9*
14,5*
21,5*
31*
41,5*
14,7
18,4
24,8
30,9
36
42,5
52

12,4 10* 7,4*


16,2 14* 11,4*
22,8 20,7* 18,2* 15,4*
29 26,8* 24,4* 21,8*
33 30* 27*
40 37,5* 34,5* 31,5*
49,5 47* 44* 41* 37,5*

Maximum suction lift 1-2 m.


Tolerances according to ISO 9906, annex A.

NM4

Close Coupled Centrifugal Pumps

60 Hz

with threaded ports

Characteristic curves n = 1750 rpm


10

0 U.S. g.p.m.
10

0 Imp. g.p.m.

20

30

10

0 U.S. g.p.m.

20

12

NM4 25/12

30
ft

A 114

m
6

45

50

52.5
52.5

20
10

A 144

40

30
20

NM4 25/160
45

35

50
30
ft

52%

m
8

20

54%

0 Imp. g.p.m.

10

25

10

B 130

50

25

47.5
15

50

20

6
10

0
0.20

Q m3/h

2
0.4

0.25

0.05

Q m /h

0 U.S. g.p.m. 10
0 Imp.g.p.m.

A 194

20

30

10
30

40

20
35

30

40

B 175

15

NM4 25/200

60
ft
50

40

42
43.5

C 157

72.550

35
40

10

30

30
20

5
10
0
1.0

Q m3/h 2

10

P
kW
0.4

1.0
P
HP
0.6

B
C

0.4

0.2

0.2
0

0
10

30

8
NPSH
6
m
4
2

0
1.2

0.8

NPSH
20
ft
10

Q m3/h 2

72.552

0.5
0.4
P
0.3
HP
0.2

A
B

0.1
0
15

4
NPSH
3
m
2

NPSH
10
ft

15

4
NPSH
3
m
2

Q m3/h

0.3
P
0.2
kW
0.1

0.20
P
0.15
HP
0.10

20

10

0.15
P
0.10
kW
0.05

15
4

10

32

NPSH
10
ft
5

Q m /h
3

72.551

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


0 U.S. g.p.m.
10

20

30

0 Imp.g.p.m. 10

20

A 143

50

55

50

30

40

60

0 U.S. g.p.m.

50

0 Imp.g.p.m. 10

20

NM4 32/16

60

30

40

20

50

30

25
55

60

40

50

NM4 32/20
A 178

15

60

m
6

20

30
ft

62.5%

B 131

40

20

35

40

50

45

B 170

50
51.5

50

40

50

10

15

60
ft

52.5%

45

30

40

20

10
5

0
0.4

Q m3/h

15

10

0.8

0.1

10
5

0 U.S. g.p.m.

10

25

50

75

A 144
B 132

72.553

15

NM4 40/16

30

20

0.8
P
0.6
HP
0.4

30

NPSH
20
ft
10
5

Q m3/h

0 Imp.g.p.m.

40
20

60
40

80

15

100

60

80

NM4 40/20

20

A 178

15

H (ft)

72.554

10

1.0

45

50 52.5

55

B 168

60
ft
50

57.5
58%

10

40
55

10

0,8

Q m /h

l/min

5
100

10

15
200

20
300

0,8

P (kW)

0,6

0,4

20

0,4

0,2

5
1.2

Q m3/h 4

12

16

60

1.5

A
B

P
kW
0.6

24

20

1.0

0,2

0
80

1
P
HP
0.5

0.4

40

0.2

20
6

10
2
0
0

Q m3/h

10

15

20

72.555N

25

20

6
NPSH
4
m
2

NPSH (ft)

(%)

30

25
400

0,6

NPSH (m)

52.5
50

0
0
0

P (HP)

0.2

0 U.S. g.p.m. 20

100

C 121

H (m)

8
NPSH
6
m
4

NPSH
20
ft

Q m3/h

15

10

10

30

Q m3/h

8
NPSH
6
m
4

0.6
P
0.4
kW
0.2

0.4
P
0.3
HP
0.2

10

10

0
0.5

0.3
P
O.2
kW
0.1

10

33

NPSH
10
ft

Q m3/h 4

12

16

20

72.556

24

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


50

100

150

12

100

150

200

A 156
10

80

B 216
C 194

NM4 50/16

B 144

30

70

8
60

H (m)

H (m)

50

H (ft)

20

50

90

NM4 40/25

A 227

0 U.S. g.p.m.

40
10

20

H (ft)

0 U.S. g.p.m.
30

30

10

20

10
15
200

l/min

20
300

25
400

30
500

2,0

35

1,0

1
0

0,0
80

20

30
400

40

50
800

600

1,5

A
B

1,0
0,5
0

50

0
8

40
10
8

30

20

20

6
4

10

2
0

10

Q m3/h

15

0 U.S. g.p.m.50

20

100

25

150

30

200

72.557N

NPSH (m)

20

10

35

Q m3/h 10

0 U.S. g.p.m.

250

20

50

A 188

72.558N

40

150

50

200

80

A 225

60

NM4 50/20

30

100

25

20

NM4 50/25

B 220

70

C 201

20

15

60

B 164

40

50

15

H (m)

H (ft)

H (m)

C 154
10

NPSH (ft)

60

40
10

H (ft)

(%)

40

NPSH (ft)

(%)

10
200
l/min
3

Q m /h

70

60

NPSH (m)

1,2
1,0
0,8
0,6
0,4
0,2
0
80

0
0
0

P (HP)

10

Q m /h

P (kW)

P (kW)

0
0
3,0

P (HP)

30

20
5

20

10
3

10

Q m /h 200
l/min

20

30
400

40

50
800

600

1,5

1,0

0,5

10
200
l/min
3

Q m /h

20

30
400

40

50
800

600

A
B

3
2

0
70

60

(%)

60
40

50
40

10
2
0

Q m3/h 10

20

30

40

50

72.559N

60

30
8
20

6
4

10

2
0

34

Q m3/h 10

20

30

40

72.560N

50

NPSH (ft)

NPSH (m)

20
6

NPSH (ft)

(%)

0,0
80

NPSH (m)

0
0

2,0

P (kW)

60
1000

P (HP)

0
0

P (kW)

2,5

P (HP)

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


0 U.S. g.p.m.

100

0 Imp. g.p.m.

200
100

0 U.S. g.p.m. 100

300
200

200

0 Imp.g.p.m.

100

A 182

45 50 55 60

400

300
200

300

16

12

NM4 65/16
10
m
8

65

55 60 65

A 148

35

70

B 137

69

40
67.5
65

32

70

75

20

65

48
ft

69,5%

12

25

72.5

77.5

C 129

67.5

B 171

30
ft

72.5

NM4 65/20

60

78%

8
75

24

15

4
10

16
4

2
0
1.6

Q m3/h

20

40

80

60

1.2
P
0.8
kW
0.4

0
4

40

60

100

80

2.0

0.4

5
P
HP

3
P
2
kW
1

1.6
P
1.2
HP
0.8

Q m3/h 20

3
2
1

8
15

4
NPSH
3
m
2

25

NPSH
6
m

NPSH
10
ft

20
NPSH
15
ft
10

5
1
0

Q m3/h

20

40

0 U.S. g.p.m. 100


0 Imp.g.p.m.

200

100

72.561

60

300

2
80

40

0 U.S. g.p.m. 100

400

200

Q m3/h 20

0 Imp.g.p.m.

300

28

60

200

100

72.579

80

300
200

100

400
300

40
ft

A 224

24

50

55

H
m
20

B 213

NM4 65/25
60 62.5

64%
62.5

50

55
60

B 266

NM4 65/31

100
63%

C 245

60

55

16

80

48

50

120
ft

62

30

64

60

A 283

80

12

20

55

60

32
8

40

16

4
0
8

Q m3/h 20

40

60

100

80

6
P
4
kW
2

10

10
P
HP

40

60

100

80

10

P
kW
6

14
P
HP
10

8
6

Q m3/h 20

25

NPSH
6
m
4
2
0

Q m3/h 20

40

60

80

72.567

20

6
NPSH
4
m
2

20
NPSH
15
ft
10

NPSH
10
ft

0
100

35

Q m3/h 20

40

60

80

72.564

0
100

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


10
8

H
m
6

0 U.S. g.p.m. 100


0 Imp.g.p.m. 100

200

A 154

300

200

60 65
67.5

300

400

NM4 80/16

D 69%

67.5
65

B 139
C 128

500
400

60

55

10

A 183

B 174

300

200
60 65 70

75

C 164

300

400

500
400

600
500

NM4 80/20
D 76%

70

65

40

60

80

10

0
6
5
NPSH
4
m
3
2
0 Q m3/h 20
0 U.S. g.p.m.
0 Imp. g.p.m.
A 228

0
0 Q m3/h
5
4
P
kW
2
1
0
6
5
NPSH
4
m
3
2
0 Q m3/h

0
120
5
P
HP
2.5

100
A

40
200

60
300

200

50 55 60

300

65 67.5

B 217

18
NPSH
14
ft
10
100 72.565 120

80
400

500
400

67.5

C 200

70
10

600
500

NM4 80/25

71

65

D 72%

60

80
ft
60
40
20

0
0 Q m3/h
10
8
P
kW
4
2
0
8
6
NPSH
4
m
2
0
0 Q m3/h

50

100
B

0
150
12
P
8
HP
4
0

50

100

72.563

40
ft
30
20

3
P
2
kW
1

20

10

0
0 Q m3/h 20
4

200

15

30
25
ft
20

30

15

0 U.S. g.p.m.
0 Imp. g.p.m.

20
NPSH
10
ft
0
150
36

50

0
150
6
P
4
HP
2

100

0
NPSH
15
ft
10
50

100

72.566

150

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


0 U.S. g.p.m.
0 Imp. g.p.m.
40
 288


m

 270

30

 257

200

200
50 55

300

300

400

60 63
65

500
400



D 67%

500
0 U.S. g.p.m.
200
300
400
600
500
0 Imp.g.p.m. 200
200
300
400
70
 355 40 45 50

55
60
 335
D 56%
m


316
50
50
54
45
40
40
30

600
500

65

63

60




120
ft
100
80

20

10
0
20
16
P
kW
8
4
0
10
8
NPSH
6
m
4
2
0

60

m3/h

50

100




20

40
150
24
P
16
HP
8

10
0
30

m3/h

50

100

72.568

m3/h

50

100

0
8
NPSH
6
m
4

30
NPSH
20
ft
10
150

37

ft
150
100
50

20
P
kW
10

200

150
40
30
P
20
HP
10
0

m3/h

50

100

72.569

25
NPSH
20
ft
15
10
150

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


0 U.S. g.p.m. 200
400
600
400
0 Imp.g.p.m. 200
15
70 75
A 185
H
60 65
m B 170
D 79%
10 C 157

800

600

25

NM4 100/20
75

70

H A 229

40
ft

m
20 B 216

6
P
4
kW
2
0
10
8
NPSH
6
m
4
2
0 Q m3/h

40

50

100

0 U.S. g.p.m. 250


0 Imp.g.p.m. 250

A 286
H B 267
m
30 C 250

A 8P
HP
4

500

55 60 65

70

150
750

500
D 72%

72.570

NM4
100/315
70
65
60

20

30
NPSH
20
ft
10
200

55
50

60

A 347

m
50

B 323

100
ft

80

1000
800

NM4 100/25

75

75

120

70

160

65

60

100

150

200

20

15
P
10
kW
5

16
12
NPSH
8
m
4
0
0 Q m3/h 50

100

150

200

24

0
250
30
P
20
HP
10

80

120
500

55 60

160
750

500

20
240
10
P
HP
5

1000

750

NM4 100/400

65 66

D 67.5%

66

67

200
ft

65

62.5

150

100
0 Q m3/h 50

100

150

200
A
B

30
P
20
kW
10
10
8
NPSH
6
m
4
2
0 Q m3/h 50
38

30

18
NPSH
14
ft
10
200 72.571 240

40

40
NPSH
20
ft
0
72.572
250

55

30
0 Q m3/h 50

70
ft
60

40

200

40

50

80

50

A
B

C 297

10
0

600

800

D 78%

0 U.S. g.p.m. 250


0 Imp.g.p.m. 250

1000

750

400

74

5
0 Q m3/h 40
10
8
P
6
kW
4
2
0
6
5
NPSH
4
m
3
2
0 Q m3/h 40

0
200

150

600

10

10
100

55 60 65 70

15

20

50

400

30

65

0
0 Q m3/h
8

0 U.S. g.p.m. 200


0 Imp.g.p.m. 200

100

150

200

250
60
P
40
HP
20
30
NPSH
20
ft
10
72.573
250

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


600
0 U.S. g.p.m. 300
600
0 Imp.g.p.m. 300
25
60
65 70
 233
75
m
20  217

900

900

1500
1200


 
75

 189

70

 175

65

10

m
30

0 U.S. g.p.m. 400


0 Imp.g.p.m. 400
 288

65 70

 271

800

800

40

1200

1600


 

75

D 78%

 258

75

50
60

1200

70

20

100

 354

m
50

 333

300

200




10
0  m3/h
40

0
10
8
NPSH
6
m
4
2
0  m3/h

20
NPSH
ft
10
100

200
600

600

60 65

900

70

300

900

1200

72.574

1500
1200




D 73%

70

 318

0
360

40

200
180
160

65

140
ft
120
100

30
0  m3/h

0
10
8
NPSH
6
m
4
2
0  m3/h

100

200

300


80
360
 80
 60
P
40
HP
20
0
30
NPSH
ft
20

100

200

300

72.576

10
360
39

ft
100

60

100

200

30
P
20
kW
10

20
P
HP
10

0 U.S. g.p.m. 300


0 Imp.g.p.m. 300
60

20
360

120

80

65

30

5
0  m3/h
20
16
P
kW
8
4
0
8
6
NPSH
4
m
2
0
0  m3/h

60
P
40
kW
20

40

80
70
ft
60

D 78%

 203

15

1200

40
400

300




40
P
HP
20
0

100

200

300

72.575

30
NPSH
20
ft
10
400

NM4

Close Coupled Centrifugal Pumps

60 Hz

with flanged connections

Characteristic curves n = 1750 rpm


40
m
30
20

0 U.S. g.p.m. 500


0 Imp.g.p.m. 500
 288

1000

55 60 65 70

1000

1500

1500

0 U.S. g.p.m. 500


0 Imp.g.p.m. 500

2000



D 77%

75

 272
 253
 244

100
ft

75

70

 357

m
50

 335

65

60 65
70

1500

1000
75

10

1500

2000

 

 318

ft
150

75

76

70
100

30
0  m3/h 100

200

300

400

40
30
P
20
kW
5
8
6
NPSH
4
m
2
0
0  m3/h 100




200

300

400

24
0  m3/h 100
80

0
500
60

P
 40
HP
20

72.577

200

300

20
NPSH
10
ft
0
500

40

500

400

60
P
40
kW
20
0
10
8
NPSH
6
m
4
2
0  m3/h 100

200

D 77%

40

50

60

1000

 100


200

300

400

80
P
HP
40
20
0

30
NPSH
20
ft
10
72.578
500

NM4

60 Hz

Close Coupled Centrifugal Pumps

Dimensions and weights


1
f
a

l1
DN2

l2

DN2

h3

DN1

h2

g1 h1
4.93.098

m2

n3

m1

b
n2

n1

Standard construction
NM4

Picture

mm

DN1 DN2
DN1

kg
a

ISO 228
1

NM4 25/12A-60/A
G 11/2 G 1
NM4 25/160AE-60,BE-60
NM4 25/200AE-60,BE-60,CE-60

h1

h2

h3

m1 m2

n1

n2

n3

56 313 90 140 199 37,5 27,5 170 130 9


56 380 100 160 228 37,5 27,5 190 150 30
63 385 125 180 253 45 32,5 245 200 49

l1

l2

38 9,5 85 88 250 10
38 9,5 102 102 250 10
45 11,5 125 125 250 11

13,5
17,5
25-23-21,5

Bronze construction B-NM4


B-NM4

Picture

mm

DN1 DN2
DN1

kg
a

ISO 228
1

B-NM4 25/160AE-60,BE-60
G 11/2 G 1
B-NM4 25/200AE-60,BE-60,CE-60

h1

h2

h3

m1 m2

n1

n2

n3

56 380 100 160 228 37,5 27,5 190 150 30


63 400 125 180 253 45 32,5 245 200 49

l1

l2

38 9,5 102 102 250 10


45 11,5 125 125 250 11

19-19
27-25-23

l1

l1

l2

l2

a
DN2

DN2

DN2

DN2

h2
DN1

DN1

h2

h3

h3

g1 h1

4.93.061.2

h1

4.93.059

g1
n3

m2

n2

m1
w

m2

m1

n1

n2
n1

Flanges EN 1092-2
C

Bronze construction B-NM4

g2

DN

mm
Picture

B-NM4

kg
DN1 DN2

h1

h2

h3 m1 m2 n1

n2

n3

l1

l2

g1

132
160
132
160

160
180
160
180

260
288
260
288

190
190
190
212

47
62
47
62

50
50
50
50

14
14
14
14

120
140
119
140

120
140
119
140

255
255
255
255

12
12
12
12

38-38
43-41
41-40-38
52-52

15

54
60

10
12

175 175

156
125

73-70
89

50

14

127 141 255 12

52-52

15

54
60

10
12

156
175 175
125

77
105-92

65

14

B-NM4 32/16A-60,B-60
B-NM4 32/20A-60,B-60
B-NM4 40/16A-60,B-60,C-60
B-NM4 40/20A-60,B-60

50
50
65
65

32 80
32 80
40 80
40 100

410
410
410
430

B-NM4 4025/B-60/A,C-60/A
B-NM4 4025/A-60/A

65

40 100

535
318 205 175 190 140
190 225
560
350 280 250 230 190

B-NM4 50/16A-60,B-60

65

50 100 430 160 180 288 100 70 265 212 62

B-NM4 5025/C-60/A
B-NM4 5025/A-60/A,B-60/A

65

535
318 205 175 190 140
50 100
190 225
560
350 280 250 230 190

B-NM4 65/16B-60,C-60
B-NM4 65/16A-60

80

65 100

100
100
100
100

70
70
70
70

240
240
240
265

430
288
62
160 200
125 95 280 212
495
306
60

41

150 172

255
15
300

4.93.094

60-60
68

mm
Holes
DN

g2
N

32

76 100 140

19

18

40

84 110 150

19

18

50

99 125 165

19

20

65 118 145 185

19

20

80 132 160 200

19

22

NM4

60 Hz

Close Coupled Centrifugal Pumps

Dimensions and weights

l1

l1

l2

l2

l
DN2

DN2

DN2

DN2

h2
DN1

DN1

h2

h3

h3

g1 h1

4.93.061.2

g1

h1

4.93.100

n3

m2

m2

n2

m1

s
n2

m1

n1

n1

Standard construction

Flanges

EN 1092-2

mm
NM4

Picture

kg
DN1 DN2

NM4
NM4
NM4
NM4

32/16AE-60,BE-60
32/20AE-60,BE-60
40/16A-60/A,B-60/A,C-60/A
40/20AE-60,BE-60

h1

h2

h3

m1 m2

n1

n2

n3

l1

l2

g1

132
160
132
160

160
180
160
180

260
288
268
288

100
100
100
100

240
240
240
265

190
190
190
212

120
140
119
140

255
255
255
255

12
12
12
12

70
70
70
70

50
50
65
65

32 80
32 80
40 80
40 100

410
410
410
430

47
62
47
62

50
50
50
50

14
14
14
14

120
140
119
140

NM4 40/25B-60/A,C-60/A
NM4 40/25A-60/A

65

40 100

495
308
180 225
125 95 320 250 60
525
340

65

14

175 175

NM4 50/16A-60/A,B-60/A

65

50 100 430 160 180 288 100 70 265 212 62

50

14

127 141 255 12

NM4 50/20C-60/A
NM4 50/20A-60/A,B-60/A

65

50 100

440
62
160 200 288 100 70 265 212
505
60

50

14

140 153

265
14
310

44,5
54,5-49,5

NM4 50/25C-60/A
NM4 50/25A-60/A,B-60/A

65

50 100

308
490
125 95 320 250 60
180 225
530
340

65

14

175 175

300
15
330

65,5
85,5-77,5

NM4 65/16BE-60,CE-60
NM4 65/16AE-60

80

65 100

62
430
160 200 288 125 95 280 212
495
60

65

14

150 172

255
15
300

46-46
51,5

NM4 65/20BE-60
NM4 65/20AE-60

80

65 100

505
308
180 225
125 95 320 250 60
525
340

65

14

155 175

310
15
330

58,5
73,5

NM4 65/25BE-60
NM4 65/25AE-60

80

540
360
65 100
200 250
160 120 360 280 60
645
385

345
175 190
18
415

NM4 65/31BE-60,CE-60
NM4 65/31AE-60

80

65 125

670
225 280 410 160 120 400 315 75
720

100

455
290
62
80 125
180 225
125 95 320 250
520
308
60

NM4 80/20CE-60
NM4 80/20AE-60,BE-60

100

540
308
80 125
180 250
125 95 345 280 60
560
340

65

NM4 80/25CE-60
NM4 80/25AE-60,BE-60

100

80 125

565
360
200 280
160 120 400 315 60
670
385

NM4 80/31CE-60
NM4 80/315AE-60,BE-60

100
100

80 125 720 250 315 435 160 120 400 315 90


80 125 850 260 315 466 435 395 314 254 -

NM4 80/400CE-60
NM4 80/400BE-60
NM4 80/400AE-60

125

80

NM4 100/20BE-60,CE-60
NM4 100/20AE-60

125 100 125

NM4 100/25BE-60
NM4 100/25AE-60

80

415
20
465

DN
K
D

4.93.094

40-39,5

mm

Holes

DN

g2

32

76 100 140

19

18

97
116

40

84 110 150

19

18

50

99 125 165

19

20

164-153
176

65 118 145 185

19

20

80 132 160 200

19

22

100 156 180 220

19

24

255
165 193
15
300

53
63-58

19

24

72
91-82

125 184 210 250

14

320
170 194
15
340

150 211 240 285

23

26

80

18

191 210

335
20
415

102
135-124

200 266 295 340

23

30

20

80
74

18
14

220 232 465 20


220 232 210 6

181
250-227

25

78
78
84

14 270
216
14 270 268 268 216
18 290
233

565
360
200 280
160 120 360 280 60
665
385

80

18

180 212

330
20
410

99-90
109

125 100 140

685
225 280 410 160 120 400 315 75
735

80

18

205 233

415
20
465

143
152

NM4 100/315BE-60,CE-60
NM4 100/315AE-60

125 100 140

865 260
466 435 395 314 254
315
880 250
- 432 382 350 279

20
25

74
78

14

210
230 250
270
223

261-240
313

NM4 100/400CE-60
NM4 100/400AE-60,BE-60

125 100 140

920
290 355
980

20
25

78
84

221
14 270
268 280
233
18 290

368
450-427

NM4 125/25DE-60,EE-60
NM4 125/25CE-60

150 125 140

685
250 355 435 160 120 400 315 90
735

80

18

235 268

415
20
465

161-149
173

20

74

14

235 268 210

242-222

14 270
216
14 270 247 278 216
18 290
233

331
365
414

865 270
125 905 270 355
970 290

482 397 350 279


520 435 350 279
540 455 396 318

435 395 350 279


540 455 396 318

NM4 125/250AE-60,BE-60

150 125 140 865 260 355 466 435 395 314 254

NM4 125/315CE-60
NM4 125/315BE-60
NM4 125/315AE-60

880
150 125 140 920 270 355
980

NM4 125/400CE-60
NM4 125/400AE-60,BE-60

150 125 140

65

18

64-59
78

g2

220 220

80

18

300
15
330

30,5-30
36-34,5
35-33-31
41-40,5

NM4 80/16CE-60
NM4 80/16AE-60,BE-60

14

336
365
436

482 397 350 279


520 435 350 279
540 455 396 318

25

78
78
84

980 300
400
1045 325

540

455 396 318


461 440 356

25

84
92

18

290
233
280 305
330
274

6
8

459
585-550

NM4 150/315DE-60
NM4 150/315CE-60
NM4 150/315AE-60,BE-60

900
200 150 160 940 290 400
1000

435 395 371 300


435 395 371 300
540 455 396 318

20
20
25

78
78
84

229
14 270
14 270 260 298 248
233
18 290

363
372
437-424

NM4 150/400BE-60,CE-60
NM4 150/400AE-60

200 150 160

1065 325
450
1145 320

540 461 440 356


625 535 500 406

25 92 18 330
274
295 328
45 104 22 355
290

590-555
614

42

N, N4

60 Hz

End-Suction Centrifugal Pumps


Construction
Single-stage end-suction centrifugal pumps, with bearing
bracket.
Nominal duty points and main dimensions in accordance
with EN 733 (DIN 24255).
Back Pull-Out construction, for simple and quick dismantling
and reassembly.
The pumps in bronze are supplied fully painted.
Rated speed of rotation (60 Hz): N = 3450 rpm
N4 = 1750 rpm
Connections: PN 10 flanges EN 1092-2.
Counter-flanges (on request)
Sizes
Flanges
from 32-160 to 50-250
Screwed flanges PN 16 EN 1092-1
from 65-125 to 150-400 Flanges for welding
PN 10 EN 1092-1
Shaft sealing
Standardized mechanical seal in accordance with ISO 3069.
Stuffing box seal (on request).

Applications
- For clean liquids, without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
- For water supply.
- For heating, air conditioning, cooling and circulation plants.
- For civil and industrial applications and for agriculture.
- For fire fighting applications.
- For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Maximum permissible rotation speed: see table on page 46.

Pump-Motor unit
Materials
Components
Pump casing
Lantern bracket
Impeller

Shaft
Shaft sleeve
Mechanical seal
Counter-flanges

N, N4
N, N4
B-N, B-N4
Mechanical seal
Stuffing box
Mechanical seal
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
For 32-125, 32-160, 32-200, 40-200
Chrome steel
Cr-Ni-Mo steel
Carbon steel
1.4104 EN 10088
1.4401 EN 10088
C
40
UNI
7845
(AISI 430)
(AISI 316)
Bronze
_
_
G-Cu Sn5 Zn5 Pb5 EN 1982
with chromate surface
_
Carbon - Ceramic - NBR
Carbon - Ceramic - NBR
Steel Fe 430B UNI 7070

43

N,N4 pump connected to a standard electric motor in B3


construction form (IEC 72), classification scheme EFF2 or
EFF1 (High efficiency) on request, IP 55 protection, threephase 380-415 V , 60 Hz by means of a baseplate, driven by
a flexible coupling and with coupling protection.

Special features on request


- Special mechanical seal.
- Chrome-nickel steel AISI 316 pump-shaft.
- Higher or lower liquid or ambient temperatures.
- Other motor protection.
- Explosion proof construction in accordance with Directive
94/9 EEC (ATEX).
- Motor for other voltage.

60 Hz

End-Suction Centrifugal Pumps

Coverage chart n = 3450 rpm


30
20

40

50

30

40

U.S. g.p.m.
50

100

200

Imp. g.p.m.

100

300
200

500

400
300

400

1000
500

2000
1000

130

400

100

300

H
m

N 40-250

N 65-250

N 50-250

50
40

N 32-200

N 40-200

N 50-200

N 32-160

N 40-160

N 50-160

N
50M

N 80-250

N 100-250

200

H
ft

N
80-200

N 65-200

N 100-200

30

N12 65-160
N 50-125

N 40-125

N 80-160

N
65-125

20
N 32-125

100
90
80
70
60
50
40

10

30

20
5
5

100

9 10
150

m 3/h

Q l/min

20
300

30
400

40

500

50

200

100
2000

1000

3000

300

500

400

8000

4000 5000

72.843.C

Performance n 3450 rpm


B-N
B-N 32/125F-60/A
B-N 32/125D-60/A
B-N 32/125D-60/A
B-N 32/125A-60/A
B-N 32/125A-60/A
B-N 32/125S-60/A
B-N 32/160B-60/A
B-N 32/160B-60/A
B-N 32/160A-60/A
B-N 32/160A-60/A
B-N 32/200D-60/A
B-N 32/200D-60/A
B-N 32/200C-60/A
B-N 32/200A-60/A
B-N 32/200A-60/A

B-N 40/125F-60/A
B-N 40/125C-60/A
B-N 40/125A-60/A
B-N 40/160C-60/A
B-N 40/160C-60/A
B-N 40/160B-60/A
B-N 40/160B-60/A
B-N 40/160A-60/A
B-N 40/160A-60/A
B-N 40/200C-60/A
B-N 40/200C-60/A
B-N 40/200B-60/A
B-N 40/200AR-60/A
B-N 40/200AR-60/A
B-N 40/200A-60/A
B-N 40/250C-60/A
B-N 40/250B-60/A
B-N 40/250A-60/A

N 32/125F-60/A
N 32/125D-60/A
N 32/125D-60/A
N 32/125A-60/A
N 32/125A-60/A
N 32/125S-60/A
N 32/160B-60/A
N 32/160B-60/A
N 32/160A-60/A
N 32/160A-60/A
N 32/200D-60/A
N 32/200D-60/A
N 32/200C-60/A
N 32/200A-60/A
N 32/200A-60/A

kW
0,55
0,75
1,1
1,1
1,5
1,5
1,5
2,2
2,2
3
2,2
3
3
4
5,5

HP
0,75
1
1,5
1,5
2
2
2
3
3
4
3
4
4
5,5
7,5

kW
1,1
1,5
2,2
2,2
3
2,2
3
4
5,5
4
5,5
5,5
5,5
7,5
7,5
9,2
11
15

l/min

H
m

Q
m3/h

P2

N 40/125F-60/A
N 40/125C-60/A
N 40/125A-60/A
N 40/160C-60/A
N 40/160C-60/A
N 40/160B-60/A
N 40/160B-60/A
N 40/160A-60/A
N 40/160A-60/A
N 40/200C-60/A
N 40/200C-60/A
N 40/200B-60/A
N 40/200AR-60/A
N 40/200AR-60/A
N 40/200A-60/A
N 40/250C-60/A
N 40/250B-60/A
N 40/250A-60/A

Q
m3/h

P2

HP
1,5
2
3
3
4
3
4
5,5
7,5
5,5
7,5
7,5
7,5
10
10
12,5
15
20

l/min

H
m

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

110
14
19,5
19,5
24,5
24,5
26
31
31
36,5
36,5
39
39
45
57
57

125
13,5
19
19
24
24
26
30,5
30,5
36
36
38
38
44,5
56,5
56,5

140
13
19
19
24
24
25,5
30
30
35,5
35,5
37,5
37,5
44
56
56

160
12,5
18,5
18,5
23,5
23,5
25,5
29,5
29,5
35
35
36,9
36,9
43
55,5
55,5

180
12
18
18
23
23
25
29
29
34
34
35
35
42
55
55

200
11,5

220
10,5

250
9

280

315

350

400

450

500

17,5

16,5

15,5

22
24,5

21,5
24

20
22,5

21*

19*

16,5*

12,5*

28
33
33

27

25*

23*

32,5

31*

29*

34
41
54
54

32
40
53
53

37

34*

51

49*

15

16,8

18,9

21

24

27

30

33

37,8

39

42

45

48

54

250
15,4
18,5
22,5
25,5
25,5
31
31
37,1
37,1
44
44
52
56,5
56,5
59,5
65,4
71,5
90,4

280
14,9
18,1
22,3
25,1
25,1
30,6
30,6
36,9
36,9
43
43
51,5
56
56
59
65
71,3
90,2

315
14,3
17,6
21,9
24,4
24,4
30,3
30,3
36,5
36,5
42
42
50,5
55
55
58,5
64,4
70,8
89,7

350
13,4
17
21,4
23,6
23,6
29,6
29,6
36,1
36,1
41
41
49,5
54
54
58
63,5
70,3
89,1

400
11,8
15,8
20,6
22,1
22,1
28,5
28,5
35,2
35,2

450
10
14,2
19,6

500
7,8
12,4
18,3

550
5,6
10,5
16,7

630

650

700

750

800

900

6,9
13,7

12,9

20,1
27,1
27,1
34,3
34,3

17,8

15,4

10,6

25,4
33,2
33,2

23,2
31,8
31,8

19,2

18,1

28,8

27,9

25,6

23

39
47,5
52
52
56
61,5
68,9
88,5

36
44,5

40

35

49
53,5
58,6
66,4
87,3

50,5
54,2
63,3
86,1

47
49
59,2
83,8

44

38,5
50
78

76

60 Hz

End-Suction Centrifugal Pumps

Performance n 3450 rpm


B-N

B-N 50/125F-60/A
B-N 50/125D-60/A
B-N N 50/125A-60/A
B-N 50/125A-60/A
B-N 50/160B-60/A
B-N 50/160B-60/A
B-N 50/160A-60/A
B-N 50/200B-60/A
B-N 50/200A-60/A
B-N 50/250C-60/A
B-N 50/250B-60/A
B-N 50/250A-60/A
B-N 50M/E-60/A
B-N 50M/D-60/A
B-N 50M/C-60/A

B-N

B-N 65/125E-60/A
B-N 65/125C-60/A
B-N 65/125A-60/A
B-N 65/160E-60/A
B-N 65/160D-60/A
B-N 65/160C-60/A
B-N 65/160B-60/A
B-N 65/160A-60/A
B-N 65/200C-60/A
B-N 65/200B-60/A
B-N 65/200A-60/A
B-N 65/250C-60
B-N 65/250B-60
B-N 65/250A-60

B-N

B-N 80/160E-60/A
B-N 80/160E-60/A
B-N 80/160D-60/A
B-N 80/160C-60/A
B-N 80/160B-60/A
B-N 80/160A-60/A
B-N 80/200B-60
B-N 80/200A-60
B-N 80/250E-60
B-N 80/250D-60
B-N 80/250C-60
B-N 80/250B-60
B-N 80/250A-60
B-N 100/200E-60
B-N 100/200D-60
B-N 100/200C-60
B-N 100/200B-60
B-N 100/200A-60
B-N 100/250B-60
B-N 100/250A-60

P2

N 50/125F-60/A
N 50/125D-60/A
N 50/125A-60/A
N 50/125A-60/A
N 50/160B-60/A
N 50/160B-60/A
N 50/160A-60/A
N 50/200B-60/A
N 50/200A-60/A
N 50/250C-60/A
N 50/250B-60/A
N 50/250A-60/A
N 50M/E-60/A
N 50M/D-60/A
N 50M/C-60/A

kW

HP

2,2
3
4
5,5
5,5
7,5
7,5
9,2
11
11
15
18,5
11
15
18,5

3
4
5,5
7,5
7,5
10
10
12,5
15
15
20
25
15
20
25

P2

N 65/125E-60/A
N 65/125C-60/A
N 65/125A-60/A
N 65/160E-60/A
N 65/160D-60/A
N 65/160C-60/A
N 65/160B-60/A
N 65/160A-60/A
N 65/200C-60/A
N 65/200B-60/A
N 65/200A-60/A
N 65/250C-60
N 65/250B-60
N 65/250A-60

kW

HP

4
5,5
7,5
5,5
7,5
9,2
11
15
15
18,5
22
22
30
37

5,5
7,5
10
7,5
10
12,5
15
20
20
25
30
30
40
50

P2

N 80/160E-60/A
N 80/160E-60/A
N 80/160D-60/A
N 80/160C-60/A
N 80/160B-60/A
N 80/160A-60/A
N 80/200B-60
N 80/200A-60
N 80/250E-60
N 80/250D-60
N 80/250C-60
N 80/250B-60
N 80/250A-60
N 100/200E-60
N 100/200D-60
N 100/200C-60
N 100/200B-60
N 100/200A-60
N 100/250B-60
N 100/250A-60

N Standard construction.
B-N Bronze construction.

kW

HP

7,5
9,2
9,2
11
15
18,5
22
30
22
30
37
45
55
18,5
22
30
37
45
55
75

10
12,5
12,5
15
20
25
30
40
30
40
50
60
75
25
30
40
50
60
75
100

Q
m3/h

24

27

30

33

37,8

42

48

54

60

66

69

72

75

84

l/min

400

450

500

550

630

700

800

900

1000

1100

1150

1200

1250

1400

16,1
19,4
24,8
24,8
35,3
35,3
41,7
50,4
57,3
60,3
73,2
86,9
47,5
58
69

15,4
19
24,6
24,6
34,9
34,9
41,6
49,8
56,9
59,3
72
86,2
47
57,5
68,5

14,2
18
24
24
33,6
33,6
41,2
48,5
55,7
57,2
70,1
84,7
46
56
67,5

13
17
23,4
23,4

11,1
15,5
22,3
22,3

8,6
13,5

5,8
11,1

8,4

20,8

19

17

16

14,8

13,6

32,4
40,3
47,1
54,6
55
68,1
83
45
55
66,5

30,1
38,5
44
52,2
50
64,3
79,8
42
53
64,5

27,5
36,3
40,5
49,5
44
59,3
76
38,5
50,5
62,5

24,5
33,8
36
46
36,5
52,8
72
34
47,5
60,5

20,9
30,9
30,2
41,8

19
29,4
27,3
39

17,1
27,8

15,1
26,1

36,2

33,2

43,8
66,9
29
44
57,5

26
42
56

24
40
54

20
36,5
51

25*
42*

42

48

54

60

66

75

84

96

108

120

132

150

168

2000

2200

2500

2800

13*
18*
22,5*
27*
31*
38,5*
45*

27*
35*
41*

H
m

51
57,6
61,9
74,6
87,6

50,6
57,7
61,2
73,9
87,3

Q
m3/h

37,8

l/min

630

700

800

900

1000

1100

1250

1400

1600

1800

19
23
27

18,5
22,5
26,5

18
22
26
20
26
30
33,5
37,5
44
49,5
56
64
79,5
90

17
21,5
25,5
19,5
25,5
29,5
33
37
43,5
49
55,5
63
79
89,5

16
21
25
19
25
29
32,5
37
43
48,5
55
62,5
78,5
89

15
19,5
24
18
24,5
28,5
32
36,5
42,5
48
54,5
61,5*
78*
88,5*

13*
17,5
22
17
23,5
27,5
31
36
41
47,5
54
60*
77*
87*

15*
19,5*
15
22
26,5
29,5
34,5
40
46,5
53,5
57,5*
75*
86*

13*
19,5*
24*
28*
33*
37,5*
44,5*
51*
54,5*
71*
83*

10*
16,5*
21*
25*
30*
35*
42*
48*
50*
66,5*
78,5*

H
m

4
20,4

Q
m3/h

75

84

96

108

120

132

150

168

180

192

210

240

270

300

l/min

1250

1400

1600

1800

2000

2200

2500

2800

3000

3200

3500

4000

4500

5000

19,5
19,5
23
27,5
34
38,5
46,5
56
51
65
73,5
84
94,5

19
19
22,5
27
33,5
38
46
55,5
50
64
73
83,5
94

18
22
25,5
33
37,5
45,5
55
48,5
62,5
72
82,5
93

17,5*
21*
25*
32,5*
37*
44,5
54
46,5
61
70,5
81
92,5
30
36
45
54
61,5
73,5
90,5

16,5*
19,5*
24,5*
31,5*
36,5*
43,5*
53,5*
44,5*
59*
69*
80*
91,5*
29,5
35,5
44,5
53,5
61
73
90

15*
18*
23*
31*
36*
42*
52*
42*
56,5*
67*
78*
90*
29
35
44
53
60,5
72,5
90

13*
15*
20*
28*
33*
39*
49*
38*
53*
63*
74*
87,5*
28
34
43
52,5
60
71,5
89

16*
22,5* 18*
28,5* 24*
35*
32*
46*
43*
33*
29*
49*
45*
59*
55*
70*
67*
84*
80*
27
26*
33
32*
42,5
41*
51,5
50*
59,5
59*
70
69*
88,5 87,5*

41*
51*
62,5*
76,5*
24,5*
31*
40*
49*
58*
67*
87*

22,5*
29*
39*
47,5*
56*
65*
85*

19*
24*
34*
43*
52,5*
60*
81*

28*
38*
48*
55*
75*

42
48
67

H
m

P2 Rated motor power output.


H Total head in m.

45

Maximum suction lift 1-2 m.


With 1 m suction head.
Tolerances according to ISO 9906, annex A.

N4

60 Hz

End-Suction Centrifugal Pumps

Coverage chart n = 1750 rpm


10 U.S. g.p.m. 20

30

10 Imp. g.p.m. 20

40
30

50

100

40

50

200
100

400 500

300
200

1000

400 500

300

2000

1000

3000

2000

70
200

N4

50

N4 80-400
N4 100-400

40

N4 125-400

ft
N4 150-400

30

N4 80-315

N4 65-315

100
90
80
70
60

N4 100-315
N4 125-315

20

N4 40-250

N4 65-250

N4 50-250

N4 150-315

N4 80-250

50

N4 100-250

m
N4 32-200

N4 40-200

40

N4 50-200

N4 65-200

10

N4 125-250
N4 80-200

30
N4 100-200

N4 40-160

N4 32-160

N4 50-160

N4 65-160

20
N4 80-160

5
N4 65-125

N4 32-125

N4 40/125

N4 50-125

10

2
1.5

2
30

3
40

50

5
80

7 8 9 10

100

150

20
30
m3/h
Q l/min
300 400 500

40

50

200

100

3000 4000 5000

2000

1000

7
700

400 500

300

10000
72.838.C

Performance n 1750 rpm

B-N4 32/160B-60/A
B-N4 32/160A-60/A
B-N4 32/200B-60/A
B-N4 32/200A-60/A
B-N4 40/160C-60/A
B-N4 40/160B-60/A
B-N4 40/160A-60/A
B-N4 40/200B-60/A
B-N4 40/200A-60/A
B-N4 40/250C-60/A
B-N4 40/250B-60/A
B-N4 40/250A-60/A

B - N4
B-N4 50/160B-60/A
B-N4 50/160A-60/A
B-N4 50/200C-60/A
B-N4 50/200B-60/A
B-N4 50/200A-60/A
B-N4 50/250C-60/A
B-N4 50/250B-60/A
B-N4 50/250A-60/A
B-N4 65/160C-60/A
B-N4 65/160B-60/A
B-N4 65/160A-60/A
B-N4 65/200B-60/A
B-N4 65/200A-60/A
B-N4 65/250B-60
B-N4 65/250A-60
B-N4 65/315C-60
B-N4 65/315B-60
B-N4 65/315A-60

N4 32/160B-60/A
N4 32/160A-60/A
N4 32/200B-60/A
N4 32/200A-60/A
N4 40/160C-60/A
N4 40/160B-60/A
N4 40/160A-60/A
N4 40/200B-60/A
N4 40/200A-60/A
N4 40/250C-60/A
N4 40/250B-60/A
N4 40/250A-60/A

kW

HP

0,37
0,37
0,55
0,75
0,37
0,55
0,75
1,1
1,1
1,5
2,2
3

0,5
0,5
0,75
1
0,5
0,75
1
1,5
1,5
2
3
4

P2

N4
N4 50/160B-60/A
N4 50/160A-60/A
N4 50/200C-60/A
N4 50/200B-60/A
N4 50/200A-60/A
N4 50/250C-60/A
N4 50/250B-60/A
N4 50/250A-60/A
N4 65/160C-60/A
N4 65/160B-60/A
N4 65/160A-60/A
N4 65/200B-60/A
N4 65/200A-60/A
N4 65/250B-60
N4 65/250A-60
N4 65/315C-60
N4 65/315B-60
N4 65/315A-60

Q
m3/h

P2

N4

kW

HP

1,1
1,1
1,1
1,5
2,2
2,2
3
4
1,1
1,1
1,5
2,2
3
4
5,5
5,5
7,5
9,2

1,5
1,5
1,5
2
3
3
4
5,5
1,5
1,5
2
3
4
5,5
7,5
7,5
10
12,5

l/min

H
m

2,4

3,6

4,2

4,8

5,4

40

50

60

70

80

90

12

13,2

l/min

180

200

9
10,55
11,2
12,8
16,7
18,9
23,1
24,1

9
10,6
11,2
12,8
16,8
18,9
23,1
24,1

15

16,8 18,9

220

250

280

9
10,6
11,1
12,8
16,9
18,9
23,1
24,1

8,95
10,6
11
12,75
16,9
18,8
23
24

8,8
10,6
10,8
12,6
16,9
18,5
22,8
23,8

H
m

46

8,4

9,6 10,8

12

13,2

15

16,8 18,9

21

24

27

30

100 125 140 160 180 200 220 250 280 315 350 400 450 500

7,6 7,6 7,5 7,4 7,4 7,3 7,1


9,2 9,2 9,1 9,1
9
9
8,8
13,1 13 12,9 12,8 12,6 12,4 12,2
14,9 14,8 14,7 14,6 14,5 14,3 14,1
6,75 6,75
8,1 8,1
9,7 9,7
13,3 13,2
15,3 15,2
18,3 18,2
22,7 22,7
25,1 25

Q
10,8
m3/h

7,5

6,6
8,3
11,4
13,6
6,65
8
9,65
13,1
15,1
18,1
22,7
25

6,1
7,8
10,8
13,2
6,53
7,95
9,6
13
15
18
22,6
24,9

21

24

27

315

350

400

8,55
10,5
10,4
12,3
16,8
18,2
22,6
23,6

8,25
10,3
10
11,9
16,6
17,8
22,2
23,2
6,6
7,9
9,3
12,5
14,5
19
23,2
27
32
36

7,7
9,9
9,1
11,3
16,3
17,1
21,5
22,6
6,6
7,8
9,3
12,4
14,4
19
23,1
27
32
36

5,3
7,2
9,8
12,4
6,35
7,8
9,5
12,7
14,7
17,9
22,6
24,9

4,4
6,4
8,7
11,4
6,15
7,6
9,37
12,5
14,5
17,6
22,5
24,8

5,4*
7,3*
10*
5,9
7,4
9,2
12
14
17,3
22,3
24,6

30

33

450

500

7
9,3
8
10,5
15,74
16,2
20,5
21,9
6,5
7,7
9,2
12,3
14,3
18,8
23
26,5
31,5
35,5

6,25
8,6
6,8
9,4
15,2
15,1
19,5
21
6,4
7,7
9,2
12,2
14,2
18,7
23
26
31
35

5,7*
8,5*
5,53
7,2
9
11,5
13,7
16,8
22,1
24,4

4,9
6,75
8,7
10,5
13
15,7
21,6
24

4,2
6,25
8,3
9,5
12,2
14,2
20,6
23,6

3,2
5,5
7,8
7,8
10,8
11,8
19,2
22,6

4,6
7

5,8

9,3
8,9 4,4
17,5 14,2 10,1
21,3 18,5 15 10,7*

37,8

42

48

54

60

66

75

84

550

630

700

800

900 1000 1100 1250 1400

5,4
7,9
5,3
8,1
14,4
13,3
18,2
19,7
6,3
7,5
9,1
12,1
14,1
18,6
22,8
26
31
35

3,8*
6,6*
2,7
5,8
13
10,3
15,3
17
6
7,2
8,9
11,7
13,9
18,3
22,6
25,5
30,5
34,5

8,5

5,4

5,2
6,5
8,1
10,8
13,1
17,5
21,8
24,5
29,5
33,5

4,5 3,7
5,8
5
4,1*
7,5 6,8
6* 4,5*
10
9,2 8,3* 6,6*
12,5 11,8 11* 9,5* 8*
16,8 15,6 14,2* 11,8* 9*
21,2 20,4 19,2* 17* 14*
23,5 22 20* 17* 13*
29
28 26,5* 24* 20,5*
33
32 31* 29* 26,5*

5,3*
3,4
11,2
7,2*
12*
14*
5,7
7
8,6
11,4
13,6
18
22,4
25
30
34

N4

60 Hz

End-Suction Centrifugal Pumps

Performance n 1750 rpm


B-N4

B-N4 80/160C-60/A
B-N4 80/160B-60/A
B-N4 80/160A-60/A
B-N4 80/200C-60
B-N4 80/200B-60
B-N4 80/200A-60
B-N4 80/250C-60
B-N4 80/250B-60
B-N4 80/250A-60
B-N4 80/315C-60
B-N4 80/315B-60
B-N4 80/315A-60
B-N4 80/400C-60
B-N4 80/400B-60
B-N4 80/400A-60

B-N4

B-N4 100/200C-60
B-N4 100/200B-60
B-N4 100/200A-60
B-N4 100/250B-60
B-N4 100/250A-60
B-N4 100/315C-60
B-N4 100/315B-60
B-N4 100/315A-60
B-N4 100/400C-60
B-N4 100/400B-60
B-N4 100/400A-60

B-N4

B-N4 125/250E-60
B-N4 125/250D-60
B-N4 125/250C-60
B-N4 125/250B-60
B-N4 125/250A-60
B-N4 125/315C-60
B-N4 125/315B-60
B-N4 125/315A-60
B-N4 125/400C-60
B-N4 125/400B-60
B-N4 125/400A-60
B-N4 150/315D-60
B-N4 150/315C-60
B-N4 150/315B-60
B-N4 150/315A-60
B-N4 150/400C-60
B-N4 150/400B-60
B-N4 150/400A-60

P2

N4
N4 80/160C-60/A
N4 80/160B-60/A
N4 80/160A-60/A
N4 80/200C-60
N4 80/200B-60
N4 80/200A-60
N4 80/250C-60
N4 80/250B-60
N4 80/250A-60
N4 80/315C-60
N4 80/315B-60
N4 80/315A-60
N4 80/400C-60
N4 80/400B-60
N4 80/400A-60

kW

HP

1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
9,2
11
15
18,5
22
30

1,5
2
3
3
4
5,5
5,5
7,5
10
12,5
15
20
25
30
40

P2

N4
N4 100/200C-60
N4 100/200B-60
N4 100/200A-60
N4 100/250B-60
N4 100/250A-60
N4 100/315C-60
N4 100/315B-60
N4 100/315A-60
N4 100/400C-60
N4 100/400B-60
N4 100/400A-60

kW

HP

3
4
5,5
7,5
9,2
11
15
18,5
22
30
37

4
5,5
7,5
10
12,5
15
20
25
30
40
50

N4 125/250E-60
N4 125/250D-60
N4 125/250C-60
N4 125/250B-60
N4 125/250A-60
N4 125/315C-60
N4 125/315B-60
N4 125/315A-60
N4 125/400C-60
N4 125/400B-60
N4 125/400A-60
N4 150/315D-60
N4 150/315C-60
N4 150/315B-60
N4 150/315A-60
N4 150/400C-60
N4 150/400B-60
N4 150/400A-60

N4 Standard construction.
B-N4 Bronze construction.

30

33

37,8

42

48

54

l/min

500

550

630

700

800

900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500

H
m

5,3
6,6
8,6
10,9
12,5
14,2
17,4
20,8
24,2
28,5
32,5
37,5
49,5
56,5
63,5

5,2
6,5
8,5
10,8
12,5
14,1
17,3
20,8
24,2
28,5
32,5
37,5
49,5
56,5
63,5

5,1
6,4
8,4
10,7
12,4
14
17,1
20,7
24,1
28,5
32,5
37,5
49
56
63

5
6,3
8,3
10,6
12,3
14
17
20,7
24
28
32
37
49
55,5
63

4,9
6,1
8,1
10,5
12,1
13,9
16,6
20,5
24
27,5
32
37
48
55
62,5

4,5
5,9
7,9
10,3
12
13,8
16,1
20,1
23,9
27,5
31,5
36,5
47
54,5
62

4,1
5,5
7,6
10
11,7
13,5
15,8
19,8
23,4
27
31,5
36,5
46
53
61

3,8
5,2
7,3
9,7
11,4
13,4
15,2
19,4
23
27
31
36
44
52
60

3
4,6
6,9
9,1
10,6
12,8
14,1
18,3
22
26
30,5
35,5
41
49,5
58

3,7
6,1 4,5
8,2 6,7
9,8 8,5 6,5*
12
11 9,2* 7,4*
13 11,3 9,5*
17,3 15,7 13,8* 11,5*
21,1 19,4 17,5* 15,2* 12,7*
25
23 21* 18*
29,5 28 25,5* 23* 21*
35
33 31,5* 29,5* 27*
37,5 32 25*
47
41 35* 27*
55,5 52 46* 40* 33,5*

Q
m3/h

48

54

60

66

75

84

96

108

120

132

l/min

800

900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500

H
m

9,4
11,7
14
19,4
22,4
28
32,5
38,5
43
51,5
59,5

9,4
11,7
14
19,4
22,4
28
32,5
38,5
42,8
51,3
59,3

9,2
11,6
13,9
19,3
22,2
27,9
32,4
38,3
42,5
51
59

9,1
11,5
13,9
19,2
22,1
27,9
32,3
38,3
42,5
50,8
58,8

8,9
11,4
13,8
19
21,9
27,5
32
38
42
50,5
58,5

8,5
8
7,2 6,4 5,5
4*
11,2 10,8 10
9,2 8,3 6,5* 4,6*
13,7 13,3 12,7 12 11,3 9,8* 8,2* 7*
18,6 18 17,4 16,5 15,5 13,8* 11,5* 10*
21,4 21 20,4 19,6 18,8 17* 15* 13,3*
27
26
25 23,5 22 19,5* 15,5* 13*
31,5 31 30,5 29,5 28,5 26* 22,5* 20*
37,9 37,5 37
36
35 32,5* 30* 28*
42
41
40 38,5 37 34* 30,5* 28*
50,3 50
49
48
46 44* 41* 39*
58,3 58 57,7 57
56 53,5* 51* 49*

84

96

108

120

132

150

Q
m3/h

P2

N4

Q
m3/h

kW

HP

5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
18,5
22
30
37
45
55
75

7,5
10
12,5
15
20
25
30
40
50
60
75
25
30
40
50
60
75
100

60

168

66

180

75

84

192

210

96

150

240

108

168

270

120

180

300

132

192

150

168

180

192

210

210

5,5*
8,2*
11,6*
10*
17,5*
26*

13,5*
21*

37*
47*

33*
44*

330

360

240

270

300

330

5,5*
8,8*

390

420

450

480

l/min 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

H
m

11,2
14
16,8
19,4
23
28
32
37
45,5
51,7
59,5

11
13,9
16,6
19,2
22,9
27,8
31,7
36,7
45
51,5
59,3

10,7
13,7
16,4
19
22,8
27,5
31,5
36,5
44,8
51,3
59

10,4
13,4
16,1
18,8
22,7
27,3
31
36
44,6
51
58,8

10
13
15,8
18,6
22,5
27
30,8
35,8
44,5
50,7
58,7
22,8
25,8
30,5
35,6
45,5
51
59

9,4
12,4
15,2
18
22
26,5
30,5
35,5
44,3
50
58
22,6
25,6
30,4
35,5
45
50,5
58,5

8,5
11,6
14,6
17,4
21,5
25,5
29,5
35
43,5
49,5
57,5
22,3
25,4
30,2
35,4
44,5
50
58,3

P2 Rated motor power output.


H Total head in m.

47

8
11
14
17
20,9
25
29
34,5
43
49
57
22
25,2
30,1
35,3
44
49,5
58

7,3
10,4
13,3
16,3
20,3
24
28,5
34
42
48
56,5
21,8
24,9
30
35,2
43,8
49,3
57,8

6,2
9,3
12,3
15,2
19,2
23
27
32,5
40
46,5
55,5
21,2
24,4
29,8
35
43,5
49
57,5

7,3*
10,3*
13,2*
17,2*
20*
25*
30,5*
36,5*
43,5*
53*
20
23,2
29
34,4
42
48
57

5*
8*
10,8*
14,9*
17*
22*
28*
32,5*
40*
50*
18,5
21,9
27,9
33,7
40,5
46,5
55,5

5,4*
8*
12,2*
13*
18,5*
25*
28*
35,5*
46*
16,7
20,2
26,5
32,5
38,5
44,5
54

9*
14,5*
21,5*
31*
41,5*
14,7
18,4
24,8
30,9
36
42,5
52

12,4 10* 7,4*


16,2 14* 11,4*
22,8 20,7* 18,2* 15,4*
29 26,8* 24,4* 21,8*
33 30* 27*
40 37,5* 34,5* 31,5*
49,5 47* 44* 41* 37,5*

Maximum suction lift 1-2 m.


Tolerances according to ISO 9906, annex A.

N, N4

60 Hz

End-Suction Centrifugal Pumps

Interchangeability of parts
Bearing housing

Pump shaft

Ball bearings

Shaft sealing

TYPE
1

N, N4 32-125
N, N4 32-160
N, N4 32-200
N, N4 40-125
N, N4 40-160
N, N4 40-200C
N, N4 40-200A-AR-B
N, N4 40-250
N, N4 50-125
N, N4 50-160
N, N4 50-200
N, N4 50-250
50M
N
N, N4 65-125E
N, N4 65-125A-C
N, N4 65-160
N, N4 65-200
N, N4 65-250
N4 65-315
N, N4 80-160
N, N4 80-200
N, N4 80-250
N4 80-315
N4 80-400
N, N4 100-200
N, N4 100-250
N4 100-315
N4 100-400
N4 125-250
N4 125-315
N4 125-400
N4 150-315
N4 150-400

ll

lll

lV

6207 Z
6306 Z

6207 Z
3306

6309 Z
3309

6311 Z
3311

3600 rpm
32-160
40-160
50-160

65-125

65-160

3450 rpm
32-200
40-200
50-200

65-200
80-200
100-200

80-160

2000 rpm
40-250
50-25
50M
65-250
80-250
100-250
125-250

65-315
80-315
100-315
125-315
150-315

80-400
100-400
125-400
150-400

Suction pipe: recommended minimum inside diameter (DN) for different capacities (Q)
Threaded pipe

G2

G 2 1/2

DN

mm

50

65

80

100

125

150

200

250

300

Q max

m /h

10.5

19

28.8

45

75

108

215

350

508

48

Maximum permissible rotation speed


32-125
40-125
50-125

50

40

32

N, N4

End-Suction Centrifugal Pumps


standardized EN 733

60 Hz

Dimensions and weights

f
DN2

l1

l2

h1

DN1

h2

4.93.113

m2

s1

14

m1

110
w

n2
n1

Flanges

Shaft extension ISO 775 Parallel key UNI 6604

PN 10, EN 1092-2
mm

mm

24 j6
32 k6
42 k6

4.93.114

8
50
80 10
110 12

t
27
35
45

g2

DN

4.93.094

32
40
50
65
80
100
125
150
200

76
84
99
118
132
156
184
211
266

100
110
125
145
160
180
210
240
295

140
150
165
185
200
220
250
285
340

Holes

rpm

4
4
4
4
8
8
8
8
8

N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N
N, N4
N, N4
N, N4
N, N4
N4
N, N4
N, N4
N, N4
N4
N4
N, N4
N, N4
N4
N4
N4
N4
N4
N4
N4

32-125
32-160
32-200
40-125
40-160
40-200
40-250
50-125
50-160
50-200
50-250
50M
65-125
65-160
65-200
65-250
65-315
80-160
80-200
80-250
80-315
80-400 (1
100-200
100-250
100-315
100-400
125-250
125-315
125-400
150-315
150-400

19
19
19
19
19
19
19
23
23

g2

18
18
20
20
22
24
24
26
30

rpm
mm

TYPE
TIPO
B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N,
B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N4 B-N4 B-N, B-N4 B-N, B-N4 B-N4 B-N4 B-N4 B-N4 B-N4 B-N4 B-N4 -

N n = 3450
N4 n = 1750

DN

DN1

DN2

50

32

80

360

65

40

80
360
100

65

50

100

360

h1

h2

l1

l2

112
132
160
112
132
160
180
132

140
160
180
140
160
180
225
160
180
200

93
120
140
100
119
140
175
121
127
140

97
120
140
113
119
140
175
137
141
153

225

175

175

180
200
225
250
280
225
250
280
315
355

134
150
155
175
220
165
170
191
220
268
180
205
230
268
235
247
280
260
295

155
172
175
190
220
193
194
210
232
268
212
233
250
280
268
278
305
298
328

160
180

80

65

100
125

360
470
360

100
125
125

80
80
100

125
125
125

470
530
470

140
530
470

150
200

125
150

140
160

530
530

160
180
200
225
180
200
250
280
200
225
250
280
250
280
315
280
315

280
315
355
355
400
400
450

1) Additional size

49

m1

m2

100

70

100

70

125

95

100

70

125

95

125

95

n1

n2

s1

50

14

24

260

100

14

24

260

100

14

24

260

100

65

14

24

260

80

18

32

340

65

14

24

260

190

140

240

190

210
240
265
320
240

160
190
212
250
190

265

212

50

320

250

65

280

212

320
360
400
320
345

250
280
315
250
280

50
65

160

120

125

95

160

120

400

315

80

18

32

340

160

120

435
360

355
280

80

18

42

370

160

120

400

315

80

18

32

340

200
160

150
120

500
400

400
315

100
80

22
18

42
32

370
340

200

150

500

400

100

22

42

370

200

150

550

450

100

22

42

370

100
140

140

140
140

140
140

kg
B-N
N
B-N4 N4
30,7
38,2
44,8
34,1
40
48,5
62,3
44
45,8
52,3
64,4
66
51,6
52,5
60
95,5
136
63
90,5
112
139,5
202
102
121,5
151,5
211,5
140
198
232
213
262

60 Hz

End-Suction Centrifugal Pumps


standardized EN 733

Dimensions
T
a

n=

f
DN2

3450 rpm

h3

h3

DN1

h2

d
4.93.070

L3

L2

L3

L1

TYPE
POMPA
B-N, N 32-125

B-N, N 32-160

B-N, N 32-200

B-N, N 40-125

B-N, N 40-160

B-N, N 40-200

B-N, N 40-250

B-N, N 50-125

B-N, N 50-160
B-N, N 50-200
B-N, N 50-250

B-N, N 50 M

B-N, N 65-125

B-N, N 65-160

B-N, N 65-200

B-N, N 65-250

B-N, N 80-160

B-N, N 80-200
B-N, N 80-250

B-N, N 80-250
B-N, N 100-200

B-N, N 100-200
B-N, N 100-250

MOTOR
MOTORE
-

71 B2
80 A2
80 B2
90 S2
90 S2
90 L2
100 L2
90 L2
100 L2
112 M2
132 SA2
80 B2
90 S2
90 L2
90 L2
100 L2
112 M2
112 M2
132 SA2
132 SB2
132 MA2
160 MA2
160 MB2
90 L2
100 L2
112 M2
132 SA2
132 SB2
132 MA2
160 MA2
160 MA2
160 MB2
160 L2
160 MA2
160 MB2
160 L2
112 M2
132 SA2
132 SB2
132 SA2
132 SB2
132 MA2
160 MA2
160 MB2
160 MB2
160 L2
180 M2
180 M2
200 LA2
200 LB2
132 SB2
132 MA2
160 MA2
160 MB2
160 L2
180 M2
200 LA2
180 M2
200 LA2
200 LB2
225 M2
250 M2
160 L2
180 M2
200 LA2
200 LB2
225 M2
250 M2
280 S2

B3

B3

B2

B2

B2 < 400

B2 > 480
mm

kW
0,55
0,75
1,1
1,5
1,5
2,2
3
2,2
3
4
5,5
1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
9,2
11
15
2,2
3
4
5,5
7,5
9,2
11
11
15
18,5
11
15
18,5
4
5,5
7,5
5,5
7,5
9,2
11
15
15
18,5
22
22
30
37
7,5
9,2
11
15
18,5
22
30
22
30
37
45
55
18,5
22
30
37
45
55
75

DN1

50

50

50

DN2

32

32

32

80

80

80

360

360

360

h2

197

140

217

160

245

180

260

L1

780

780

L2

750

750

780

750

880

850

L3

15

15

15

B2

240

240

B3

180

180

90

90

h3

85

85

240

180

90

85

300

240

100

100

14

715

132
144

144
165
180
180

915

205

955

205

1060

250

14

785
835
855

144
165
180

14

14

40

80

360

197

140

780

750

15

240

180

90

85

14

65

40

80

360

217

160

780

750

15

240

180

90

85

14

65

40

100

360

260

180

880

850

15

300

240

100

100

14

40

100

360

280

225

65

50

100

360

217

160

65

50

100

360

260

65

50

100

360

260

65

50

100

360

280

880

850

1020

990

15

350

290

100

90

100

85

l
110

740
740
765
815
765
815
835
895
715
740
765
765
815
835
855

65

65

T
685

14

144
165
144
165
180
205
132
144

780

750

15

240

180

180

880

850

15

300

240

100

100

14

915

205

200

880
1020

850
990

15

300
350

240
290

100

100

14

955
1060

205
250

225

1020

990

15

350

290

100

100

14

1060

250

1100
65

50

100

360

280

225

80

65

100

360

260

180

80

65

100

360

260

200

1020

880

850

880

850

80

65

65

100

100

360

470

280

225

310

250

80

125

360

280

15

990

1020

990

1140

1110

1230
880

100

15

350

290

300

240

300

240

15
1020

80

990

1190

350

100

14

100

100

14

100

100

14

180

915

205

15

20

350

400

290

340

100

130

100

110

14

18

15

350

290

100

100

14

990

125

470

280
310

250

1140
1230

1110
1190

15
20

350
400

290
340

100
130

100
110

14
18

100

80

125

470

310

280

1230

1190

20

400

340

130

110

18

280

1250

840

205

480

430

90

20

24

100

80

125

470

385
415

125

100

125

470

310

280

1230

1190

20

400

340

130

110

18

125

100

125

470

280

470

205
205
230

480
480
510

430
430
450

24

140

840
840
940

20

100

1250
1250
1400

90

125

385
415
505

90

20

24

205

955

1060

80

50

250

1100
855

1060

290

100

280

1060

915

850

225
1020

100

1100

250
250

1235

270
270

1335

290

940
980

205

1085

250

1125
1260
1360
1260

270
290
270

1360

290

1400
1515
1235
1260

320
355
250
270

1360

290

1400
1530
1620

320
355
390

N4

End-Suction Centrifugal Pumps


standardized EN 733

60 Hz

Dimensions
n=
TYPE
POMPA
B-N4 - N4 32-125

B-N4 - N4 32-160
B-N4 - N4 32-200
B-N4 - N4 40-125

B-N4 - N4 40-160

B-N4 - N4 40-200
B-N4 - N4 40-250

B-N4 - N4 50-125

B-N4 - N4 50-160
B-N4 - N4 50-200

B-N4 - N4 50-250

B-N4 - N4 65-125

B-N4 - N4 65-160

B-N4 - N4 65-200
B-N4 - N4

65-250

B-N4 - N4

65-315

B-N4 - N4 80-160

B-N4 - N4

B-N4 - N4

80-200

80-250

B-N4 - N4

80-315

B-N4 - N4

80-400

B-N4 - N4 100-200

B-N4 - N4 100-250
B-N4 - N4 100-315

B-N4 - N4 100-400

B-N4 - N4 125-250

B-N4 - N4 125-315

B-N4 - N4 125-400

B-N4 - N4 150-315

B-N4 - N4 150-400

MOTOR
MOTORE
-

71 A4
71 A4
71 A4
71 B4
71 B4
80 A4
80 B4
71 A4
71 B4
71 B4
71 B4
80 A4
80 B4
90 S4
90 S4
90 L4
100 LA4
100 LB4
71 B4
80 A4
80 B4
90 S4
90 S4
90 S4
90 L4
100 LA4
100 LA4
100 LB4
112 M4
80 B4
80 B4
90 S4
90 S4
90 S4
90 L4
100 LA4
100 LB4
112 M4
132 S4
132 S4
132 MA4
132 MB4
90 S4
90 L4
100 LA4
100 LA4
100 LB4
112 M4
112 M4
132 S4
132 MA4
132 MB4
160 M4
160 L4
180 M4
180 L4
200 L4
100 LB4
112 M4
132 S4
132 MA4
132 MB4
160 M4
160 L4
180 M4
180 L4
200 L4
225 S4
132 S4
132 MA4
132 MB4
160 M4
160 L4
180 M4
180 L4
200 L4
225 S4
225 M4
250 M4
180 M4
180 L4
200 L4
225 S4
225 M4
250 M4
280 S4

1750 rpm

mm

kW
0,25
0,25
0,25
0,37
0,37
0,55
0,75
0,25
0,37
0,37
0,37
0,55
0,75
1,1
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,1
1,1
1,5
2,2
2,2
3
4
0,75
0,75
1,1
1,1
1,1
1,5
2,2
3
4
5,5
5,5
7,5
9,2
1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
9,2
11
15
18,5
22
30
3
4
5,5
7,5
9,2
11
15
18,5
22
30
37
5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
18,5
22
30
37
45
55
75

DN1

DN2

h2

L1

L2

50

32

80

360

197

140

780

750

50

32

80

360

217

160

780

750

50

32

80

360

245

180

780

750

65

40

80

360

197

140

780

65

40

80

360

217

160

65

40

100

360

260

65

40

100

360

280

L3

B2

B3

h3

15

240

180

90

85

14

685

110

15

240

180

90

85

14

685

110

15

240

180

90

85

14

715

132

750

15

240

180

90

85

14

685

110

685

110

780

750

15

240

180

90

85

14

180

880

850

15

300

240

100

100

14

225

880

850

15

350

290

100

100

14

715

132

760

144

785

144

835

165

705

110

735

132

65

50

100

360

217

160

780

750

15

240

180

90

85

14

65

50

100

360

260

180

880

850

15

300

240

100

100

14

760

144

14

760
785
835

144

14

835

165

65

65

50

50

100

100

360

360

260

200

280

225

880

880

850

850

15

15

300

350

240

290

100

100

100

100

80

65

100

360

260

180

880

850

15

300

240

100

100

14

80

65

100

360

260

200

880

850

15

300

240

100

100

14

165

855

180

735

132

760

144

760

144

785
80

65

100

360

280

225

880

850

15

350

290

100

100

14

80

65

100

470

310

250

1030

990

20

400

340

130

110

18

80

65

125

470

335

280

1030

990

20

400

340

130

110

18

100

80

125

360

280

225

880

850

15

350

290

100

100

100

80

125

470

280

250

1020

990

15

350

290

100

100

100

80

125

470

310

280

100

80

125

470

360

315

125

80

125

530

445

355

1030

990

1030

990

1230

1190

1250

840

20

400

340

130

110

835

165

965
1025
1050

180
205

1090

205

14

785
810
860

144

14

970

165

990
990
1050
1090
1090
1195
1235
1320
1360
1420
970
990
1050

180
180

18

20

400

340

130

110

18

205

480

430

110

20

24

125

100

125

470

310

280

1030

990

20

400

340

130

110

18

125

100

140

470

335

280

1030

990

20

400

340

130

110

18

125

100

140

470

360

315

125

100

140

530

445

355

150

125

140

470

360

355

150

150

125

125

140

140

530

530

445

355

480

400

540
200

150

160

530

200

150

160

530

445

400

480
450

540

51

1230

1190

1250

840

1030

990

20

400

340

130

110

18

205

480

430

110

20

24

20

400

340

130

110

18

1230

1190

1250

840

205

480

430

1250

840

205

480

430

1400

940

230

510

450

1250

840

205

480

430

1250

840

205

480

430

1400

940

230

510

450

110

110

20

20

24

24

110

20

24

110

20

24

1105
1210
1250
1275
1375
1435
1480
1065
1105
1210
1250
1335
1375
1435
1480
1510
1590
1355
1395
1455
1500
1530
1610
1700

165

205
205
250
270
290
165
180
205
205
250
270
270
290
320
205
250
270
290
320
355
270
290
320
320
355
390

NR, NR4

60 Hz

In-line Pumps
Construction
Close-coupled, single-impeller, centrifugal pumps; electric
motor with extended shaft directly connected to the pump.
Pump casing with suction and delivery connections with the
same diameter and on the same axis (in-line).
Connections: Flanges PN 10, EN 1092-2.
Counterflanges (on request)
Sizes
Flanges
NR,NR4 50, NR,NR4 65 Screwed flanges PN 16, EN 1092-1
NR4 80, NR4 100,
Flanges for welding
NR4 125
PN 10, EN 1092-1

Applications
For clean liquids, without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n = 1750 rpm).

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.

Materials
Component
Pump casing
Lantern bracket
Impeller
Shaft
Mecanical seal
Counterflanges

Material

Motor

Cast iron GJL 200 EN 1561

4-pole induction motor, 60 Hz (n = 1750 rpm).


NR4: three-phase 220/380 V.
NRM4: single-phase 220 V.

Cast iron GJL 200 EN 1561


(Brass P-Cu Zn Pb 2 EN 1982 for NR-NR4 50, NR-NR4 50/200)
Chrome-nickel steel AISI 303 for pumps up to 1.1 kW
Chrome steel AISI 430 for pumps from 1.5 to 4 kW
Carbon - Ceramic - NBR
Steel Fe 42 UNI 7070

2-pole induction motor, 60 Hz (n = 3450 rpm).


NR:
three-phase 220/380 V, 380/660 V.
NRM: single-phase 220 V, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with IEC 60034.

Special features on request


- Other voltages. - Protection IP 55.
- Special mechanical seal. - Higher or lower liquid or ambient temperatures.

Coverage chart
100

50

NR

NR4

40

n = 3450 rpm

NR 50/250

NR 65/250

n = 1750 rpm

30

50
NR 50/200

40

NR 65/200

20
NR4 50/250

30

NR4
65/250

NR 65/160
NR 50/160

10

NR4 50/200

20
NR 65/125

NR4 50/160

NR4
65/200

NR4 125

NR4 65/160 NR4 100

NR 50/125

10

4
NR4 50
NR 50

NR4 65

3
NR4 80

3
6
10
Q m /h
100 l/min
200

15

20
30
300
400 500

40

50
1000

100
1500

53

/h
Qm
l/min

5
100

10
150 200

20
30
300 400 500

40 50
1000

100
1500

NR

60 Hz

In-line Pumps

Performance n 3450 rpm


3~

220V 380V
A

NR 50D-60/A
NR 50C-60/A

3~

1,5 3,5 NRM 50D-60/A


2,6 4,5 NRM 50C-60/A

3~

IA/IN kW HP l/min

4,1 2,5 0,45 0,6


6,9 3,1 0,75 1

A IA/IN
3,3
5,2
6,2
6,2
7,5
11,3
11,3
14,5
18,2
21,5
25
32,5

5,3
6
5,9
5,9
9,5
9,8
9,8
8,2
9,5
8,2
8,1
8,8

A IA/IN

10,7 6,2 5,9


13 7,5 9,5
11,3 9,8
14,5 8,2
18,2 9,5
21,5 8,2
25 8,1
25 8,1
32,5 8,8
40,7 9,7

P1 Max. power input.

m3/h

H
m

0
0

6,6

7,5

8,4

100 110 125 140

9,6 10,8

12

13,2

15

16,8 18,9

160 180 200 220 250 280

12 11,7 10,8 10,5 10,2 9,5 8,5


17,3 17,4 15,9 15,8 15,7 15,3 14,6

315

7
14

6
13

11

5,5

30

33

37,8

39

42

Q
P2

220V 380V
A

NR 65/125F-60
NR 65/125D-60
NR 65/125A-60
NR 65/160B-60
NR 65/160A-60
NR 65/200B-60
NR 65/200A-60
NR 65/250C-60
NR 65/250B-60
NR 65/250A-60

P2

220V 380V

5,7
9
10,7
10,7
13

220V

A IA/IN

2,6
4,5

A
NR 50/125F-60
NR 50/125C-60
NR 50/125A-60
NR 50/160C-60
NR 50/160B-60
NR 50/160A-60
NR 50/200C-60
NR 50/200B-60
NR 50/200A-60
NR 50/250C-60
NR 50/250B-60
NR 50/250A-60

1~

P2 Rated motor power output.

m3/h

kW HP l/min
1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
9,2
11
15

1,5
2
3
3
4
5,5
5,5
7,5
10
12,5
15
20

H
m

15

16,8 18,9

21

24

27

250 280 315 350 400 450 500 550 630 650 700 750

15,2
17,9
21,3
23,1
29,9
36,1
48,4
53,4
60
68,9
76,4
92,6

14,7
17,8
21,7
24,4
29,9
36,5
45,4
50,8
57,8
65,5
73,5
90,2

14,2
17,3
21,4
23,9
29,4
36,1
44,4
50
57
64,5
72,8
89,5

13,4
16,7
20,9
23,1
28,8
35,5
43,2
48,6
56
63,3
71,5
88,6

12,5
15,9
20,4
22,2
28,1
34,9
41,7
47,3
54,8
62,3
70,5
87,6

11,1
14,7
19,4
20,6
26,9
33,7
39,4
45,4
53
60,3
68,8
86,4

9,5
13,4
18,3
19
25,5
32,1
37
43,3
51,1
58,1
66,8
84,5

7,6
11,8
17
17,1
23,9
30,4
34
40,7
48,8
55,3
64,3
82,6

5,5
10,1
15,6
14,9
22,1
28,6

21

24

27

30

33

37,8

42

48

13
10,7
18,9
25,3

45

12,2*
9,4*
18*
24,3* 22*

37,5
46,2 41,4
52,5
61,5 56,9
80,6 76,7 75,4

Q
P2

m3/h

kW HP l/min
2,2
3
4
5,5
7,5
9,2
11
11
15
18,5

3
4
5,5
7,5
10
12,5
15
15
20
25

H
m

0
16,9
19,7
24,3
34,8
41
51,2
57,6
63,2
73,1
85,3

54

60

66

69

72

75

84

350 400 450 500 550 630 700 800 900 1000 1100 1150 1200 1250 1400
16,7
19,7
24,7
35,5
41,8
50,5
57,4
63
73,4
86,1

16,3
19,4
24,6
35,1
41,6
49,9
57
62,3
72,8
85,7

15,9
19
24,3
34,7
41,4
49,1
56,2
61,5
72,3
85,3

IA/IN = D.O.L. starting current / Rated current

54

15,3
18,6
24
34,3
41
48,3
55,5
60,6
71,5
84,8

14,6
18
23,7
33,8
40,6
47,3
54,5
59,6
70,8
84

13,4
17
22,9
32,6
39,8
45,4
52,9
57,6
69,1
82,5

12,2
16
22,2
31,5
38,9
43,9
51,4
55,6
67,4
81,2

10,1
14,3
20,9
29,2
37,3
41,5
49,1
52,8
64,8
79

7,6*
12,2*
19*
26,7
35,4
38,6
46,8
49,4
61,8
76,5

4,8*
9,8*
17,6*
23,7*
32,8* 30,1*
35,1 30,9
43,9 40,5
58,4
73,6 70,3

Tolerances according to ISO 9906, annex A.

NR4

60 Hz

In-line Pumps

Performance n 1750 rpm


3~

220V 380V
A

NR4 50C-60/A
NR4 50B-60/A
NR4 50A-60/A
NR4 65C-60/A
NR4 65B-60/A
NR4 65A-60/A

3~

1,7 1 3,5
1,7 1 3,5
1,7 1 3,5
1,7 1 3,5
2,4 1,4 3,6
2,4 1,4 3,6

3,8
3,8
3,8
3,8

0,25
0,25
0,25
0,25
0,37
0,37

3,5
3,5
3,5
4,2
6
6
7,6
10,2

4,1
4,5
5
4,7
4,7
5,9
6,8
9,5

P1 Max. power input.

l/min

33

67

H
m

3,9
4,7
5,6
3,8
4,7
5,6

4
5
6

3,9
4,9
5,9

5,4

10

12

16

14

18

20

25

100 133

167 200 233 267 300 333

417

3,7
4,7
5,8
4,2
5,1
6

2,7
3,8
5,2
4,2
5
5,9

2,5
4,1
4
4,9
5,8

2,6
3,6
4,6
5,5

3
4,2
5,2

2,4
3,7
4,7

2,9
4,1

7,5

8,4

9,6 10,8

12

13,2

15

5
3,2

m3/h

0,37
0,55
0,75
1,1
1,1
1,5
2,2
3

0,5
0,75
1
1,5
1,5
2
3
4

H
m

90

6,4
7,6
9,2
13,3
14,9
18,5
23
25,4

6,5
7,8
9,4
13,1
14,8
18,5
23
25,4

6,5
7,8
9,4
13
14,7
18,4
22,9
25,3

6,3
7,7
9,3
12,7
14,4
18,1
22,7
25,2

6,2
7,6
9,1
12,4
14,1
17,9
22,6
25

6
7,5
9
12
13,8
17,6
22,4
24,8

10,8

12

13,2

15

16,8 18,9

180 200 220 250

16,8 18,9

100 125 140 160 180 200 220 250


5,7
7,3
8,7
11,6
13,4
17,2
22,1
24,6

5,5
7
8,5
11,2
13,1
16,9
21,8
24,3

5,1
6,8
8,2
10,7
12,7
16,5
21,4
24

21

24

21

24

27

30

280 315 350 400 450 500

4,5 3,9
3
6,3 5,8 5,1 4,3*
7,7
7
6,2 5,3* 3,8*
9,9 8,9 7,8
12,0 11,1 10
9
15,8 15 13,4 11,3 7,2
20,9 20,3 19,4 18,4 16,3 13
23,5 23 22,2 21,4 19,9 17,5 14

4,7
4,7
4,7
5,9
6,8
6,8
9,5
9,8

4,5
4,5
5
4,7
4,7
5,9
6,8
9,5
9,8

P2 Rated motor power output.

m3/h

kW HP l/min
1,1
1,1
1,1
1,5
2,2
2,2
3
4

1,5
1,5
1,5
2
3
3
4
5,5

P2

A IA/IN
1,8
1,8
2,3
3,5
3,5
4,2
6
7,6
10,2

kW HP l/min

P2

220V 380V

3,1
3,1
4
6
6
7,3
10,4
13,1
17,6

Q
m3/h

A IA/IN

6
6
6
7,3
10,4
10,4
13,1
17,6

0,34
0,34
0,34
0,34
0,5
0,5

P2

220V 380V

A
NR4 80CE-60
NR4 80BE-60
NR4 80AE-60
NR4 100CE-60
NR4 100BE-60
NR4 100AE-60
NR4 125CE-60
NR4 125BE-60
NR4 125AE-60

2,5
2,5
2,5
2,5

A IA/IN

3~

IA/IN kW HP

A
NR4M 50C-60/A
NR4M 50B-60/A
NR4M 50A-60/A
NR4M 65C-60/A

P2

220V 380V

2 1,1
NR4 50/160C-60
NR4 50/160B-60 3,1 1,8
4 2,3
NR4 50/160A-60
6 3,5
NR4 50/200B-60
6 3,5
NR4 50/200A-60
NR4 50/250C-60 7,3 4,2
NR4 50/250B-60 10,4 6
NR4 50/250A-60 13,1 7,6

NR4 65/160B-60
NR4 65/160A-60
NR4 65/200C-60
NR4 65/200B-60
NR4 65/200A-60
NR4 65/250C-60
NR4 65/250B-60
NR4 65/250A-60

220V

A IA/IN

3~

1~

H
m

0,75
0,75
1
1,5
1,5
2
3
4
5,5

280 315 350 400 450 500


8,8
10,6
10,1
11,8
16,2
18,5
22,7
23,9

8,6
10,4
9,6
11,5
16
18,1
22,3
23,6

8,3
10,2
9,1
11
15,7
17,7
22
23

7,8
9,8
8,3
10,3
15,2
16,9
21,5
22,7

7,2
9,3
7,2
9,4
14,6
16
20,8
22

6,6
8,8
5,8
8,4
13,8
15,1
19,9
21,2

33

37,8

42

48

550 630 700 800


5,8
8,2
4,3
7,1
13
14,1
19
20,4

4,4*
7* 5,8*

8,9
10,5
11,1
12,6
16,6
18,9
22,7
23,7

9,2
10,8
10,9
12,6
16,8
19,2
23,1
24,2

9,1
10,8
10,8
12,4
16,7
19,1
23,1
24,2

9,1
10,8
10,6
12,3
16,6
19
22,95
24,2

8,9
10,7
10,4
12,1
16,4
18,8
22,9
24,1

12

14

16

18

200 233 267 300 333 417 500 583 667 833 1000 1167 1333 1500 1667 1840

4,7
11,6
12,3
17,5
18,9

9,9
10,4
16
17,4

Q
m3/h

kW HP l/min
0,55
0,55
0,75
1,1
1,1
1,5
2,2
3
4

30

27

H
m

4,2 4,2
4,7 4,8
5,5 5,7
6,75
7,7
9,5
10,8
12,4
13,9

4,1
4,8
5,7

4
4,7
5,6

IA/IN = D.O.L. starting current / Rated current

55

3,9
4,6
5,5

20

3,8
4,5
5,4
6,75
7,7
9,4

25

3,4
4
4,8
6,7
7,6
9,3

30

2,5
3,2
4
6,6
7,5
9,2
10,9
12,7
13,9

35

2,2
3,1
6,3
7,2
9
10,8
12,6
13,8

40

1,9
6
6,9
8,6
10,7
12,5
13,8

50

4,9
6
7,7
10,5
12,4
13,7

60

70

80

90 100 110

3,5
4,5
6,5 5
9,7 8,9 7,7 5,7
12 11,2 10,2 8,8 7
13,5 12,9 12 10,9 9,4 7,7

Tolerances according to ISO 9906, annex A.

NR

60 Hz

In-line Pumps

Performance n 3450 rpm


0 U.S. g.p.m. 20
0 Imp.g.p.m.

40

60

80

40

20

60

20
45 50

C 100

H
m
15

55

60

60

NR 50
n = 3450 rpm

63%

50
ft

D 86

60

40
55

10

50
45

30
20

5
10
0

0
0
1.0

Q m3/h

10

20

15

C
0.8

1.0
P
HP

0.6

P
kW
0.2

0.5

0
0

Q m3/h

10

15

72.590

20

56

NR

60 Hz

In-line Pumps

Performance n 3450 rpm


50

U.S.g.p.m.

100

150

200

0
40

80

NR 50/125

A118

U.S.g.p.m.

50

100

50
40

B 132

100

C 121

80

20
60

H ft

10

120

F100

30

60

Hm

C108

200

NR 50/160

70

20

15

150

A 144

H ft

0
25

30

40

10

20

5
20

10

0 Q m 3/h

10

0 Q l/min

20

30

200

40

400

50

600

800

2,5

0,5

600

800
6
5
4
3
2
1
0

A
B

40

20

20

NPSH ft

4
10

2
0 Q m 3/h

10

20

50

U.S.g.p.m.

30

75

100

40

125

0
50

72.1211

150

20

6
4

10
2
0

175

0 Q m 3/h

10

20

50

U.S.g.p.m.

30

75

100

72.1212

40

125

150

0
50

175

100

NR 50/200

A 178

60

A 218

200

C 160

80

H
100

70

250

C 188

200

60

20

H ft

30

300

B 198

150

40

NR 50/250

90

H ft

B 168

50

50

150

50

10

40

300

30
400

40

500

P kW

20

B
C

0 Q m 3/h

600

2
0
80

12
10
8
6
4
2
0

30
400

40

500

600
A

12

B
C

0
80

24
20
16
12
8
4
0

60

300

40
20

40
20
0

8
20

6
4

10

2
0 Q m 3/h

10

20

30

72.1213

NPSH m

NPSH ft

NPSH m

20
200

16

60

10

0 Q l/min

P HP

20
200

P kW

10

0 Q l/min

P HP

0 Q m 3/h
10

NPSH ft

NPSH m

8
20

70

400

50

4
10

2
0

0
40

57

20

0 Q m 3/h

10

20

30

72.1213

0
40

NPSH ft

200

40

60

40

30

0
80

60

NPSH m

0 Q l/min

20

0
80

10

P kW

1,5

P HP

P kW

0 Q m 3/h

P HP

NR

60 Hz

In-line Pumps

Characteristic curves n 3450 rpm


0
30

100

U.S.g.p.m.

150

200

250

300

350
50

100

150

200

250

300

350
160

90

NR 65/125

A127

0 U.S.g.p.m.

NR 65/160

A156

80

140

40
70

10

100

H ft

30

H ft

50
40

120

60

F 106

B144

D114

20

80

30

20
60

20
10

40

0 Q l/min

30
400

40
600

50
800

60
1000

6
5
4
3
2
1
0

D
F

2
1
0
80

1000

80

1200
12
10
8
6
4
2
0

A
B

6
4

60

70

0
80

40

40
20
0

10

10

30

10

NPSH ft

20

NPSH m

30

8
20

6
4

10

2
0 Q m 3/h

U.S.g.p.m.

20

30

100

40

150

50

200

70 72.1213

60

250

300

0
80

350

0 Q m 3/h

70

U.S.g.p.m.

20

30

100

40

150

50

200

60

70

250

72.1214

300

0
80

350

100

60

NR 65/200

200

B 164

NR 65/250

90

H ft

A 174

50

80
250

B 200

40

300

A 216

150

800

60

600

50

20

NPSH m

400

40

10

60

30

NPSH ft

P kW

20

0 Q l/min

1200

10
0 Q m 3/h

0
80

70

P kW

20

P HP

0 Q m 3/h

P HP

70
C 186

100

200

60

20

H ft

30

50

150

50

10

40

600

60
800

80

1000

0 Q m 3/h

1200
A
B

15
10
5
0

40

600

60
800

80

1000

1200
30

A
B

20

10
0

40

8
20

6
4

10

2
0 Q m 3/h

20

40

60

72.1213

NPSH m

4
10

2
0

0
80

58

20

0 Q m 3/h

20

40

60

72.1213

0
80

NPSH ft

20

NPSH ft

NPSH m

20

40
400

60

60

28
24
20
16
12
8
4
0
80

20

0 Q l/min

P HP

40
400

P kW

14
12
10
8
6
4
2
0
80

20

0 Q l/min

P HP

P kW

0 Q m 3/h

NR4

60 Hz

In-line Pumps

Characteristic curves n 1750 rpm


0 U.S. g.p.m.

20

30

0 Imp.g.p.m.10

20

40

50

30

0 U.S. g.p.m. 20

60

40

50

0 Imp.g.p.m.

40

60

20

80

40

60

A 114

55

60
65%

B 105

5
m

NR4 50
60

C 97

20

ft

15

5
m

55

55

A 118

60

65 68
70

B 110

NR4 65

20

73%

ft

C 104

70
68
65

4
50
10

60

15

10

55

2
5

0
0

0.4

Q m3/h

15

10

0.4

0.5
P
HP

0.3
P
0.2
kW
0.1

0.2
0.1

0
0

Q m3/h

10

72.591

15

Q m3/h

10

A
B

0.2
0.1
0

59

0.5
P
HP
0.3

20

15

0.3
P
0.2
kW
0.1

0.3

0
0

Q m3/h

10

15

72.592

20

NR4

60 Hz

In-line Pumps

Characteristic curves n 1750 rpm


0
10

40

U.S.g.p.m.

60

80

100

120

25

U.S.g.p.m.

50

75

100

20

A144

NR4 50/160

30

NR4 50/200

60

B132

25

C121

5
15

40

H ft

B 168

50

A 178

15
20

4
10

10

30

2
5

20

10
100

15
200

20

25

300

0,7
0,6
0,5
0,4
0,3
0,2
0,1
0
80

400

0,8
0,6

B
C

0,4
0,2
0

20

10

NPSH m

20

NPSH ft

NPSH m

0 Q m 3/h

10

15

40

U.S.g.p.m.

60

20

80

25

100

72.1215

0
30

90
80

B 216

70

C 194

60

50

H ft

20

40

10

30
20
10

0 Q l/min

10
100

15
200

20
300

25

30

400

500
4

P HP

0 Q m 3/h

P kW

1,5

A
1

0,5
0

40

0
80

60
40
20
0

20

6
4

10
2

0 Q m 3/h

NPSH ft

10

15

20

25

72.1215

30

60

20

6
4

10
2
0

120

NR4 50/250

A 227

25
400

30

NPSH m

20
300

10

15
200

20

10
100

60

40

30

1,2
1
0,8
0,6
0,4
0,2
0
80

60

0 Q m /h
0 Q l/min

500

0 Q m 3/h

10

15

20

72.1216

0
25

NPSH ft

P kW

0 Q l/min

P HP

0 Q m /h

0
30

P kW

P HP

NR4

60 Hz

In-line Pumps

Characteristic curves n 1750 rpm


0

U.S.g.p.m.

50

100

150

200

12

U.S.g.p.m.

50

100

150

200

20

NR4 65/160

35

60

NR4 65/200

A 188

10

B144

50

15

30

B 164
8
7

40

C 154

H ft

25

10

30

H ft

A156

11

20

20

5
15

4
10
10

10
200

30
400

40

50

600

1,2
1
0,8
0,6
0,4
0,2
0
80

0 Q l/min

800
1,5

A
B

1
0,5
0

20

10

600

800
1,5

A
1

B
C

0,5
0

40

15

10

3
2

0 Q m3/h

U.S.g.p.m.

10

20

50

30

100

40

72.1216

150

0
50

200

A 225

80

NR4 65/200

B 220

70

C 201

20

50

15

H ft

60

NPSH m

20

NPSH ft

NPSH m

25

40

10

30

20

0 Q m 3/h
0 Q l/min

10

20
200

30
400

40

50

600

800

A
B
C

3
2

2
1

1
0
80

P HP

P kW

400

30

60

0
50

40

10

40
20
0
5

15

10

3
2

NPSH ft

NPSH m

200

30

20

1
0

20

60

40

10

2,4
2
1,6
1,2
0,8
0,4
0
80

60

0 Q m 3/h

0 Q m3/h

10

20

30

40

72.1216

50

61

0 Q m 3/h

10

20

30

40

72.1216

50

NPSH ft

P kW

0 Q l/min

20

P kW

0 Q m 3/h

P HP

P HP

NR4

60 Hz

In-line Pumps

Characteristic curves n 1750


0 U.S. g.p.m. 40
0 Imp.g.p.m.

80

120

40

160

80

0 U.S. g.p.m.

120

100

0 Imp. g.p.m.

100

10

A 115 60

H
5
m

65

NR4 80

70%

50

A 150

20
8

B 140

B 110

C 130

C 103

m
6

ft
15

65

60

200

55

300
200

60

65
67.5
68

69%

25
65

ft
60

20
55

55

15

10

50

30

NR4 100

4
10

2
5

2
5

1
0

0
0

0.8

Q m3/h

10

20

40

30

0.2

Q m3/h

10

20

0 U.S. g.p.m. 100

200

0 Imp.g.p.m. 100

300
200

30

72.593

400

500

300

40

A 183

50 55

65

400

NR4 125

B 174

40

12

65

C 164

ft

60

10
67.5

30

55

70%

20

H
m

10

2
0
0

Q m3/h 20

40

60

80

0
120

100

4
P
3
kW
2

6
P
HP
4

3
2

1
0

Q m3/h 20

40

60

80

100

72.595

2.5

120

62

2
P
1.5
HP
1

B
C

0.5
0

50
60

80

60

16
14

40

0.4

20

1.5
P
1
kW
0.5

0.6

Q m3/h

1.0
P
A HP

0.6
P
0.4
kW
0.2

0
0

Q m3/h

20

40

60

72.594

0
80

NR,NR4

60 Hz

In-line Pumps

Dimensions and weights


x

mm

DN
h1

DN

h2

TYPE
NR 50D-60/A, C-60/A
NR 50/125A-60, C-60, F-60
NR 50/160C-60
NR 50/160A-60, B-60
NR 50/200C-60
NR 50/200A-60, B-60
NR 50/250B-60, C-60
NR 50/250A-60
NR 65/125F-60
NR 65/125S-60, A-60,D-60
NR 65/160A-60, B-60
NR 65/200A-60, B-60
NR 65/250A-60
NR 65/250B-60
NR 65/250C-60

DN

h1

h2

l1

l2

50
50
50
50
50
50
50
50
65
65
65
65
65
65
65

320
340
340
340
440
440
440
440
340
340
340
475
475
475
475

360
435
437
502
512
542
702
742
452
517
549
667
672
722
747

90
90
90
90
100
100
100
100
105
105
105
105
105
105
105

270
345
347
412
412
442
602
652
347
412
444
562
567
617
642

98
-

111
128
128
128
128
160
185
185
128
128
160
185
185
185
185

93
96
120
120
140
140
175
175
121
121
121
140
175
175
175

100
115
128
128
140
140
175
175
145
145
142
153
175
175
175

70
75
75
75
80
80
85
85
95
95
95
90
90
90
90

kg
29,5-30
33,2-31,5-29,5
38,7
51,3-47,5
59,2
76,2-69,2
121-114
137
43,1
55,6-55,6-51,6
73-67
114-108
155
140
134

4.93.101.2

mm

l
l2

l1

TYPE

M16
b

NR4 50A-60/A, B-60/A, C-60/A


NR4 65A-60/A, B-60/A, C-60/A
NR4 80AE-60, BE-60, CE-60
NR4 100BE-60, CE-60
NR4 100AE-60
NR4 125CE-60
NR4 125AE-60, BE-60
NR4 50/160A-60, B-60, C-60
NR4 50/200A-60, B-60
NR4 50/250B-60, C-60
NR4 50/250A-60
NR4 65/160A-60, B-60
NR4 65/200C-60
NR4 65/200A-60, B-60
NR4 65/250C-60
NR4 65/250A-60, B-60

DN

h1

h2

l1

l2

50
65
80
100
100
125
125
50
50
50
50
65
65
65
65
65

320
360
400
500
500
600
600
340
400
400
400
340
475
475
475
475

360
370
445
485
510
540
610
437
447
552
592
454
467
532
517
557

90
100
125
150
150
160
160
90
100
100
100
105
105
105
105
105

270
270
320
335
360
370
440
347
347
452
592
349
362
532
412
557

98
118
130
162
162
194
194
-

111
111
110
110
140
140
170
128
128
128
128
128
128
128
128
128

93
102
123
153
153
172
172
120
140
175
175
121
140
140
175
175

100
114
140
173
173
195
195
128
140
176
176
142
153
153
175
175

70
70
80
105
105
120
120
75
80
85
85
95
90
90
90
90

Flanges PN 10, EN 1092-2


mm
DN

g2

DN
K
D

4.93.094

50
65
80
100
125

99
118
132
156
184

Installation

4.93.032.2

63

125
145
160
180
210

165
185
200
220
250

Holes
N

4
4
8
8
8

19
19
19
19
19

g2
20
20
22
24
24

kg
24-24-24
28-28-28
38,5-38-37,5
59-59
64
89
110-108
37,5-35,5-33,5
56
77,5-74,5
93,5
42,7-42,5
52
62-57
73
93-85

NR,NR4

60 Hz

In-line Pumps

Features

NEW COMPACT DESIGN


A compact structure allows for simple
installation even in confined spaces

ADVANCED HYDRAULICS
Optimum impeller geometry provid e s maximum efficiency and excellent
suction characteristics.

A UNIQUE DESIGN
An innovative guard (patented)
prevents contact with rotating
parts, providing protection to the
end user whilst allowing for
inspection of the mechanical
seal.

SILENT OPERATION
Specially designed fluid ducts provide
very quiet operation

EXCEPTIONAL FLUID DYNAMICS


The fluid dynamics through the impeller
and casing are designed to minimize
losses and increase performance.

64

MXH 2,4,8,16 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chromenickel stainless steel.
Compact and robust construction, without protruding flange
and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump,
accessible from any side (like the terminal box).

Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial applications, for garden use and irrigation.

Operating conditions
Liquid temperature from - 15 C to + 110 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing: 8 bar.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
MXH: three-phase 220 / 380 V.
MXHM: single-phase 220 V.
With thermal protector up to 1.1 kW.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034; IEC 60335-2-41;
EN 60335-2-41.

Materials
Component

Material

Pump casing
Stage casing
Wear ring
Impeller
Casing cover
Spacer sleeve

Chrome-nickel steel AISI 304


Chrome-nickel steel AISI 304
PTFE
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304

Pump shaft
Plug

Chrome-nickel steel AISI 303


Chrome-nickel steel AISI 303

Mechanical seal with seat


according to ISO 3069

Ceramic alumina, carbon, EPDM


(Other materials on request)

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Seal rings in FPM.
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


0 U.S. g.p.m.
0 Imp. g.p.m.

40
20

60
40

80
60

100

120

80

140

100

70

200

MXH

60

H
50
m

150

40

ft

30

100

MXH 2
20

MXH 4

MXH 8
MXH 16

50

10

0
0

m 3/h
Q l/min

8
100

16
200

300

24
400

32
500
72.833/2

65

MXH 2,4,8,16 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps

Performance n 3450 rpm


220 V 380 V

3~

1~

220 V

m3/h

P2

1,5

2,5

3,5

4,5

5
83,3

IA/IN

IA/IN

16,6

25

33,3

41,6

50

58,3

66,6

75

MXH 201-60E

1,7

4,7

MXHM 201-60E

2,3

1,8

0,25 0,34

16

15,2

14,5

13,7

13

12

10,7

9,6

8,5

MXH 202-60/A

3,3

1,9

4,3

MXHM 202-60/A

3,3

0,55 0,75

33

31

30

28,5

27

25,5

23,5

21

19

16

MXH 203-60/A

4,2

2,4

4,8

MXHM 203-60/A

6,2

3,2

0,75

49,5

47

45,5

43,5

41

38,5

35,5

32

28,5

24

MXH 204-60/A

5,4

3,1

4,2

MXHM 204-60

8,5

1,1

1,5

66

63

60,5

58

55

51,5

47,5

43

38,5

33

2,5

3,5

9
150

220 V 380 V

3~

1~

220 V

IA/IN

IA/IN

1,2

MXHM 401-60E

2,8

2,7

0,33 0,45

MXH 402-60/A

4,2

2,4

4,8

MXHM 402-60/A

6,2

3,2

0,75

MXH 403-60/A

5,4

3,1

4,2

MXHM 403-60

8,5

1,1

1,5

4,6

6,2

MXHM 404-60

10,6

3,8

1,5

220 V 380 V

1~

220 V

IA/IN

3,3

1,9

4,3

MXHM 801-60/A

MXH 802-60

4,6

6,2

MXHM 802-60

MXH 803-60

5,2

MXH 804-60

10,7

6,2

MXH 801-60/A

50

58,3

66,6

83,3

100

116

133

14

13,5

13

11,7

10,2

8,5

6,5

32,5

29,5

29

28,5

27,5

26

23,5

20,5

17

12,5

49

45,5

44,5

43,5

42

39,5

36

31,5

26,5

20

65,5

60

59

57,5

56

52,5

48,5

42,5

35,5

26

6,5

10

11

12

13

14

15

82,3

108

133

166

183

200

216

233

250

15,6

14,4

14

12,3

11,3

10

8,8

7,3

5,6

33,5

31,3

30,4

29

26,5

25

23

20,5

18

15

2,5

51

47

45

42,5

38,5

36,5

33,5

30,5

26,5

22,5

69

63

60

57,5

53

50,5

47

43

38

31

12

15

18

21

24

27

IA/IN

3,3

0,55 0,75

10,6

3,8

1,5

1,8

5,9

2,2

Hm

m3/h

P2

IA/IN

kW

HP

6,2

5,9

2,2

MXH 1603-60

7,5

9,5

P2 Rated motor power output.


IA/IN = D.O.L. starting current / Rated current

41,6
14,5

16,5

l/min

HP

kW

0
16

MXH 1602-60E 10,7

Hm

m3/h

P2

220 V 380 V

3~

l/min

HP

kW

3~

Hm

m3/h

P2

MXH 401-60E

MXH 404-60

l/min

HP

kW

l/min

Hm

100

150

200

250

300

350

400

450

35

33

31,8

30,2

28,3

26

23,5

20

15,8

52,5

49,5

47,7

45,3

42,5

39

35,2

30

23,7

DN1

DN2

Test results with clean cold water, without gas content.


Tolerances according to ISO 9906, annex A.

Dimensions and weights


L
160

TYPE

DN 2

4.93.209

88

10

(2)

L2

30

28

112

kg

mm

ISO 228

184

(1)

127

DN 1

L1

MXH MXHM

L1

L2

MXH 201-60E - MXHM 201-60E

G 1 1/4 G 1 331

94

182 176 98,5 6,6

6,7

MXH 202-60/A - MXHM 202-60/A

G 1 1/4 G 1 357

94

182 192 112

10,1

MXH 203-60/A - MXHM 203-60/A

G 1 1/4 G 1 357

94

182 192 112 10,5 11,5

MXH 204-60/A

G 1 1/4 G 1 381 118 206 192 112 12,5

MXH 401-60E - MXHM 401-60E

G 1 1/4 G 1 331

94

182 176 98,5 6,6

6,7

MXH 402-60/A - MXHM 402-60/A

G 1 1/4 G 1 357

94

182 192 112

10

11

MXH 403-60/A

G 1 1/4 G 1 357

94

182 192 112

12

MXH 801-60/A - MXHM 801-60/A

G 1 1/2 G 1 381 118 206 192 112

9,7

10,5

9,1

146

L
L1

160

(1)

DN 1

DN 2

DN1

TYPE

h2
h1

210

ISO 228

3.93.020/1

L3

(2)

L2

(1) Filling

10,5

31
10
167

10

30,5

112
146

(2) Draining

66

kg

mm

DN2
L

L1

L2

L3

h1

h2 MXH MXHM

MXHM 204-60

G 1 1/4

G1

453 118 206

88 127 184

17,7

MXHM 403-60

G 1 1/4

G1

429

88 127 184

17,2

MXH 404-60 - MXHM 404-60

G 1 1/4

G1

453 118 206

88 127 184 18,5 19,2

MXH 802-60 - MXHM 802-60

G 1 1/2

G1

453 118 206

88 127 184

MXH 803-60

G 1 1/2

G1

453 118 206

88 127 184 18,3

MXH 804-60

G 1 1/2

G1

482 148 206

88 127 184 19,8

MXH 1602-60

G2

G 1 1/2 464 128 230 101 117 187 18,3

94

206

18

18,9

MXH 2,4,8,16 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps

Characteristic curves n = 3450 rpm


0

U.S. g.p.m. 5

10

0 Imp. g.p.m.

15

20

10

15

U.S. g.p.m. 10

Imp. g.p.m.

20
10

40

20

30

70

70

MXH 204-60/A

MXH 2

60

50

200

60

150

Hm

MXH 404-60

50

MXH 203-60/A

Hm

ft

40

100

30

40

20

MXH 4

200

MXH 403-60/A

150
ft

MXH 202-60/A
30

MXH 402-60/A

100

20

MXH 201-60E

MXH 401-60E

50

50

10

10

30

0
0

m3/h

Q l/min

2
20

30

3
50

40

4
60

5
70

80

50

60

30

40

20

30

10

20

0
0

m3/h

Q l/min

3
40

6
100

5
80

60

7
120

9
140

10
160

4
4
NPSH
m
2

ft

ft

0
0
0

Q m3/h

U.S. g.p.m.

2
20

3
30

0 Imp. g.p.m.

20

40

50

30

40

72.580/1

60

Q m3/h

U.S. g.p.m.

0 Imp. g.p.m.

50

40

60
40

80

100

60

80

72.581/1

10

120
100

70

70

MXH 804-60

MXH 8

60

50

200

60

150

Hm

40

MXH 802-60

200

MXH 1603-60

150

40

ft

30

MXH 16

50

MXH 803-60

Hm

100

ft

MXH 1602-60

30

100

20

20

MXH 801-60/A

50

50
10

10

10

NPSH
m
2

10

0
0

m3/h

Q l/min

5
50

10
100

150

200

0
15
250

70

70

50

50

40

40

30

30

0
0

m3/h

Q l/min 100

10

20
200

300

400

0
30
500

15

15
4
NPSH
m 3

6
NPSH
4

ft
10

ft
10

2
5

1
0

Q m /h

10

72.582/1

0
0

15

67

Q m /h

10

20

72.582/2

30

MXH 2,4,8,16 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps

Features

3.93.001

Extra safety
against running dry, with the suction port above pump axis.

Reliable
All hydraulic parts in contact with the pumped liquid are of stainless steel.
For liquids from -15 C to 110 C.

Robust
Single-piece, thick barrel casing.

Compact
Single-piece lantern bracket and base.
Without protruding flange.

Greater protection
against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
Greater protection against water entering the motor from outside provided by an
extension of the pump casing around the lantern bracket.

68

MXHL 60 Hz AISI 316

Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chromenickel-molybdenum stainless steel AISI 316L.
Compact and robust construction, without protruding flange
and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump,
accessible from any side (like the terminal box).

6.1

Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial applications, for garden use and irrigation.

Operating conditions
Liquid temperature from - 15 C to + 110 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing: 8 bar.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
MXHL: three-phase 220 / 380 V.
MXHLM: single-phase 220 V.
With thermal protector up to 1.1 kW.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034; IEC 60335-2-41;
EN 60335-2-41.

Materials
Component

Material

Pump casing
Stage casing
Wear ring
Impeller
Casing cover
Spacer sleeve

Chrome-nickel-molybdenum steel AISI 316L


Chrome-nickel-molybdenum steel AISI 316L
PTFE
Chrome-nickel-molybdenum steel AISI 316L
Chrome-nickel-molybdenum steel AISI 316L
Chrome-nickel-molybdenum steel AISI 316L

Pump shaft
Plug

Chrome-nickel-molybdenum steel AISI 316L


Chrome-nickel-molybdenum steel AISI 316L

Mechanical seal with seat


according to ISO 3069

Ceramic alumina, carbon, EPDM


(Other materials on request)

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Seal rings in FPM.
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


0
0

20

U.S. g.p.m.

40

60

20

Imp. g.p.m.

40

60

70

200

MXHL

60

H
50
m

150

40

ft

30

100

MXHL 2

MXHL 8

MXHL 4

20

50
10

0
0

m 3/h
Q l/min

6
100

10

12
200

14

16

0
18
300
72.833/2

69

MXHL 60 Hz AISI 316

Horizontal Multi-Stage
Close Coupled Pumps

Performance n 3450 rpm


220 V 380 V

3~

1~

220 V

P2
HP

kW

m3/h

1,5

2,5

3,5

4,5

l/min

16,6

25

33,3

41,6

50

58,3

66,6

75

83,3

IA/IN

IA/IN

1,7

4,7

MXHLM 201-60E

2,3

1,8

0,25 0,34

16

15,2

14,5

13,7

13

12

10,7

9,6

8,5

MXHL 202-60/A 3,3

1,9

4,3

MXHLM 202-60/A

3,3

0,55 0,75

33

31

30

28,5

27

25,5

23,5

21

19

16

MXHL 203-60/A 4,2

2,4

4,8

MXHLM 203-60/A 6,2

3,2

0,75

49,5

47

45,5

43,5

41

38,5

35,5

32

28,5

24

MXHL 204-60/A 5,4

3,1

4,2

MXHLM 204-60

1,1

1,5

66

63

60,5

58

55

51,5

47,5

43

38,5

33

MXHL 201-60E

220 V 380 V

3~

1~

IA/IN

1,2

MXHL 402-60/A 4,2

2,4

MXHL 403-60/A 5,4

MXHL 401-60E

MXHL 404-60

P2
HP

kW

IA/IN
2,7

0,33 0,45

4,8

MXHLM 402-60/A 6,2

3,2

0,75

3,1

4,2

MXHLM 403-60

8,5

1,1

1,5

4,6

6,2

MXHLM 404-60

10,6

3,8

1,5

1~

220 V

IA/IN

1,9

4,3

MXHLM 801-60/A
MXHLM 802-60

P2

2,5

3,5

l/min

41,6

50

58,3

66,6

83,3

100

116

133

150

Hm

16

14,5

14

13,5

13

11,7

10,2

8,5

6,5

32,5

29,5

29

28,5

27,5

26

23,5

20,5

17

12,5

49

45,5

44,5

43,5

42

39,5

36

31,5

26,5

20

65,5

60

59

57,5

56

52,5

48,5

42,5

35,5

26

m3/h

6,5

10

11

12

13

14

15

l/min

82,3

108

133

166

183

200

216

233

250

16,5

15,6

14,4

14

12,3

11,3

10

8,8

7,3

5,6

33,5

31,3

30,4

29

26,5

25

23

20,5

18

15

Q
HP

kW

m3/h

2,8

A
MXHL 801-60/A 3,3

220 V

MXHLM 401-60E

220 V 380 V

3~

8,5

Hm

IA/IN

3,3

0,55 0,75

10,6

3,8

1,5

MXHL 802-60

4,6

6,2

MXHL 803-60

5,2

1,8

2,5

51

47

45

42,5

38,5

36,5

33,5

30,5

26,5

22,5

MXHL 804-60

10,7

6,2

5,9

2,2

69

63

60

57,5

53

50,5

47

43

38

31

P2 Rated motor power output.


IA/IN = D.O.L. starting current / Rated current

Hm

Test results with clean cold water, without gas content.


Tolerances according to ISO 9906, annex A.

Dimensions and weights


L
160

TYPE

DN 2

DN1

4.93.209

88

L2

30

9
10

(2)

L1

L2

MXHL 201-60E - MXHLM 201-60E G 1 1/4 G 1 331

94

182 176 98,5 6,6

6,7

MXHL 202-60/A - MXHLM 202-60/A G 1 1/4 G 1 357

94

182 192 112

10,1

MXHL 203-60/A - MXHLM 203-60/A G 1 1/4 G 1 357

94

182 192 112 10,5 11,5

MXHL 204-60/A

28

MXHL MXHLM
9,1

G 1 1/4 G 1 381 118 206 192 112 12,5

MXHL 401-60E - MXHLM 401-60E G 1 1/4 G 1 331

94

182 176 98,5 6,6

6,7

MXHL 402-60/A - MXHLM 402-60/A G 1 1/4 G 1 357

94

182 192 112

10

11

G 1 1/4 G 1 357

94

182 192 112

12

MXHL 801-60/A - MXHLM 801-60/A G 1 1/2 G 1 381 118 206 192 112

9,7

10,5

MXHL 403-60/A

112

kg

mm

DN2

ISO 228

184

(1)

127

DN 1

L1

146

L
L1

160

(1)

DN 1

DN 2

TYPE

DN1

h2

L3

(2)

L2

(1) Filling

10,5

31
10
167

10

30,5

112
146

(2) Draining

70

L1

L2

L3

h1

h2 MXHL MXHLM

MXHLM 204-60 G 1 1/4

G1

453 118 206

88 127 184

17,7

MXHLM 403-60 G 1 1/4

G1

429

88 127 184

17,2

MXHL 404-60 - MXHLM 404-60 G 1 1/4

G1

453 118 206

88 127 184 18,5 19,2

MXHL 802-60 - MXHLM 802-60 G 1 1/2

G1

453 118 206

88 127 184

MXHL 803-60

G 1 1/2

G1

453 118 206

88 127 184 18,3

MXHL 804-60

G 1 1/2

G1

482 148 206

88 127 184 19,8

210

h1
3.93.020/1

kg

mm

DN2

ISO 228

94

206

18

18,9

MXHL 60 Hz AISI 316

Horizontal Multi-Stage
Close Coupled Pumps

Characteristic curves n = 3450 rpm


0

U.S. g.p.m. 5

10
5

0 Imp. g.p.m.

15

20

10

15

U.S. g.p.m. 10

Imp. g.p.m.

20
10

40

20

30

70

70

MXHL 204-60/A

MXHL 2

60

50

200

60

150

Hm

MXHL 404-60

50

MXHL 203-60/A

Hm

ft

40

100

30

40

20

MXHL 4

200

MXHL 403-60/A

150
ft

MXHL 202-60/A
30

MXHL 402-60/A

100

20

MXHL 201-60E

MXHL 401-60E

50

50

10

10

30

0
0

m3/h

Q l/min

2
20

30

3
50

40

4
60

5
70

80

50

60

30

40

20

30

10

20

0
0

m3/h

Q l/min

3
40

60

5
80

6
100

7
120

9
140

10
160

4
4
NPSH
m
2

ft

ft

0
0
0

Q m3/h

U.S. g.p.m.

2
20

3
30

0 Imp. g.p.m.

20

40

50

30

40

72.580/1

60
50

70

MXHL 804-60

MXHL 8

60

50

200

MXHL 803-60

Hm

150

40

ft

MXHL 802-60

30

100

20

MXHL 801-60/A

50

10

10

NPSH
m
2

10

0
0

m3/h

Q l/min

5
50

10
100

150

200

0
15
250

70
%
50
40
30
5
15
4
NPSH
m 3

ft
10

2
5

1
0

Q m3/h

10

72.582/1

15

71

Q m3/h

72.581/1

10

6.1

MXHL 60 Hz AISI 316

Horizontal Multi-Stage
Close Coupled Pumps

Features

3.93.001

Extra safety
against running dry, with the suction port above pump axis.

Reliable
All hydraulic parts in contact with the pumped liquid are of stainless steel.
For liquids from -15 C to 110 C.

Robust
Single-piece, thick barrel casing.

Compact
Single-piece lantern bracket and base.
Without protruding flange.

Greater protection
against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
Greater protection against water entering the motor from outside provided by an
extension of the pump casing around the lantern bracket.

72

MXH 32,48 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chrome-nickel
stainless steel.
Compact and robust construction,with compact lantern
bracket and motor with feet.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump,
accessible from any side (like the terminal box).

6.2

Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for civil and industrial applications, for garden
use and irrigation.

Operating conditions
Liquid temperature from - 15 C to + 110 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing: 12 bar.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
MXH: three-phase 220 / 380 V, 380/660 V.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034-1.

Materials
Component

Material

Pump casing
Stage casing
Wear ring
Impeller
Casing cover
Spacer sleeve

Chrome-nickel steel AISI 304


Chrome-nickel steel AISI 304
PTFE
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304

Pump shaft
Plug

Chrome-nickel steel AISI 316


Chrome-nickel steel AISI 303

Mechanical seal with seat


according to ISO 3069-KU

Ceramic alumina, carbon, EPDM


(Other materials on request)

Special features on request


- Pump with Victaulic ports (MXH-V).
- Pump with flanged ports (MXH-F).
- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Seal rings in FPM.
- Higher or lower lambient temperatures.

Coverage chart n = 3450 rpm

120

U.S. g.p.m. 50

Imp. g.p.m.

100
50

150
100

200
150

250

300

200

250

110

MXH

100
90

300

80

ft

70
200

60

H
m

MXH 32

40
100

30

MXH 48

20
10
0

0
m3/h
0 Q l/min

10
200

20

400

30

600

40

50
800

60
1000

70
72.978/05

73

MXH 32,48 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps

Performance n 3450 rpm


380 V 660 V

3~

P2

m3/h

18

22

26

30

34

38

42

47

52

l/min

633

700

783

866

IA/IN

kW

HP

300

366

433

500

566

5,5

27

24,5

23,7

23

22

20,5

19

17,5

15

11

9,5

7,5

10

54

49

47,5

46

44

41,5

38,5

35

29

23

MXH 3203-60

6,5
18,2 10,5
25 14,4

9,8
8,1

11

15

MXH 3204-60

32,5 18,8

8,8

15

20

3~

380 V 660 V

A
MXH 3201-60
MXH 3202-60

A
MXH 4801-60
MXH 4802-60
MXH 4803-60

11,3

P2
kW

IA/IN

11,3 6,5
21,5 12,4
32,5 18,8

81

73,5

71

69

66

61,5

57

52,5

45

33

108

98

94,5

92

88

82

76

70

60

44

m3/h

27

33

39

45

48

54

60

65

70

l/min

450

550

650

750

800

900

29,5

25,5

24,5

23

21

20

17,5

15

13

59

51

49

46

42

40

35

30

26

21

88,5

76,5

73,5

69

63

60

52,5

45

39

31,5

Q
HP

9,8

5,5

8,2

9,2

12,5

8,8

15

20

P2 Rated motor power output.


IA/IN = D.O.L. starting current / Rated current

Hm

Hm

1000 1083 1166


10,5

Test results with clean cold water, without gas content.


Tolerances according to ISO 9906, annex A.

Characteristic curves n = 3450 rpm


0 Imp. g.p.m. 50

100

150

0 Imp. g.p.m. 50

200

110

100

200

150

250

90

MXH 3204

100

MXH 4803

80
300

90

70
80

MXH 3203

70

ft

60

200

200

60

MXH 4802

H
m

ft

MXH 3202

H
m

40

40

30

30

100

MXH 4801

100

MXH 3201

20

20

10

10
0

0
m3/h 10

0
Q
0

l/min

200

20
300

70

30
400

500

40
600

700

50
800

900
5

70

60
%
50

3
Pst
kW
1

50
Pst

30

40

ft
10

m
0
Q m 3/h 10

20

30

40

72.974

l/min 200

400

40
600

50
800

0
70

60
1000

5
Pst
4
kW
3

Pst

2
ft
ft
10

0
0

30

20

6
NPSH
4
m
2

20

30

8
NPSH

m3/h 10

0
0 Q m3/h 10

50

74

20

30

40

50

60

72.1035

70

MXH 32,48 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps

Designation
MXH-F 3204-60 *
Series
No code = threaded ports
Victaulic ports
Flanged ports
Rated capacity in m3/h
Number of stages
Frequency 60 Hz

V
F

6.2

Construction variants
special seal code (no code = standard seal)

Dimensions and weights


L

Threaded
ports

L1

L3

g2
n2

m2

n1

m1

DN1
DN2
ISO 228

MXH 3201-60
MXH 3202-60
MXH 3203-60
MXH 3204-60
MXH 4801-60
MXH 4802-60
MXH 4803-60

w
L2

Victaulic
ports

g3

g1

h1

DN1

h3

140

DN2

mm
n1

n2

g1

g2

g3

kg

G 2 1/2

G2

482 120,5 233

250

150

280

205

175

180

140

15

54

10

112

39

G 2 1/2

G2

534 120,5 205

250

150

310

280

250

258

190

15

68

12

84

38

55,5

G 2 1/2

G2

658 166,5 338

270

132

318

218

178

260

216

20

52

12

171,5

18

G2

754 212,5 384

18

G 2 1/2

L1

L2

L3

h1

h3

m1

m2

270

132

318

218

178

260

216

20

52

12

171,5

G3

G 2 1/2 545

136

264

250

150

280

205

175

180

140

15

54

10

127

G3

G 2 1/2 643

136

323

270

132

318

218

178

260

216

20

52

12

186,5

18

G3

G 2 1/2 754 197,5 384

270

132

318

218

178

260

216

20

52

12

186,5

18

LV

Flanged
ports

L1V
DN2

41

LF
L1F

177

175

DN2

DN
DN1

DN1

DG
DK
DE
L2V

MXH-V 3201-60
MXH-V 3202-60
MXH-V 3203-60
MXH-V 3204-60
MXH-V 4801-60
MXH-V 4802-60
MXH-V 4803-60

L2F

DN1

DN2

mm

mm

mm
LV

L1V

L2V

76,1 (DN65) 60,3 (DN50) 522

160

273

76,1 (DN65) 60,3 (DN50) 574

160

245

76,1 (DN65) 60,3 (DN50) 698

206

378

76,1 (DN65) 60,3 (DN50) 794

252

424

88,9 (DN80) 76,1 (DN65) 585

175

304

88,9 (DN80) 76,1 (DN65) 683

175

363

88,9 (DN80) 76,1 (DN65) 794

237

424

MXH-F 3201-60
MXH-F 3202-60
MXH-F 3203-60
MXH-F 3204-60
MXH-F 4801-60
MXH-F 4802-60
MXH-F 4803-60

75

Flanges*

EN 1092-2

mm

DN1

DN2

mm

mm

LF

L1F

L2F

65

50

512

151

263

65

50

564

151

235

65

50

688

197

368

65

50

784

243

414

80

65

565

156

284

80

65

663

156

343

80

65

774

218

404

Fori

DN DE DK DG

N.

50 165 125 99
65 185 145 118

4
8

19
19

80 200 160 132

19

* ASME 150 lb (ex ANSI 150 lb)

MXH 32,48 60 Hz

Horizontal Multi-Stage
Close Coupled Pumps

Features

Flexibility
Three versions of ports: threaded, flanged and Victaulic.

Extra safety
With front axis suction port for optimum suction conditions.
Reliable
All hydraulic parts in contact with the pumped liquid are made in stainless steel.
For liquids from -15 C to 110 C.

Robust
Single-piece, thick barrel casing, open on one side only, with reinforced threaded
ports.

Compact
The bracket between pump and motor is extremely compact.

Greater protection
Against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.

76

MXP 60 Hz

Horizontal Multi-Stage Close Coupled Pumps

Construction
Horizontal multi-stage close coupled pump.
Single-piece barrel casing in chrome-nickel stainless
steel, with front suction port above pumps axis and
radial delivery at top.
Stages in Noryl.

Applications
For water supply.
For domestic use, for garden use and irrigation.

Operating conditions
Liquid temperature: 0 C to +50 C.
Ambient temperature up to +40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Materials
Component

Material

Motor

Pump casing
Casing cover

Cr-Ni steel 1.4301 EN 10088 (AISI 304)


Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Pump Shaft
Plug

Chrome steel 1.4104 EN 10088 (AISI 430)


Cr-Ni steel 1.4305 EN 10088 (AISI 303)

Stage casing
Impeller

PPO-GF20 (Noryl)
PPO-GF20 (Noryl)

2-pole induction motor, 60 Hz (n = 3450 rpm).


MXP:
three-phase 220/380 V.
MXPM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

Mechanical seal

Carbon - Ceramic - NBR

Characteristic curves n = 3450 rpm


0
70

Imp. g.p.m. 5

10

15

0
50

20

Imp. g.p.m.

H
60

200

MXP 204-60

20

10

150

MXP 403-60

m
40

ft

50

MXP 203-60

150

m
40

MXP 402-60

30

100

ft

MXP 202-60

30

100

20

MXP 401-60
20

MXP 201-60

50

50

10

10
0
0
m3/h 1
Q l/min 20
0
45
40

2
40

60

0
6
100
4

5
80

0
0
55

NPSH
m

NPSH

30
25
0

Q m3 /h 1

72.1138

77

6
100

50

NPSH

50

NPSH
m
3

40

35
0

m3/h

Q l/min

m3/h

72.1139

1
8

MXP 60 Hz

Horizontal Multi-Stage Close Coupled Pumps

Performance n 3450 rpm


220 V 380 V

3~

MXP 201-60
MXP 202-60
MXP 203-60/A
MXP 204-60/A

A
1,7
3,1
4,2
4,2

A
1
1,8
2,4
2,4

IA/IN
4,7
4,8
4,8
4,8

MXPM 201-60
MXPM 202-60
MXPM 203-60/A
MXPM 204-60/A

220 V 380 V

3~
MXP 401-60
MXP 402-60/A
MXP 403-60/A

A
2
4,2
5,4

A
1,2
2,4
3,1

220 V

1~

1~
IA/IN
4
4,8
4,2

P1 Max. power input.


IA/IN = D.O.L. starting current / Rated current

P2

A
2,3
4,1
6,2
6,2

IA/IN
1,8
2,7
3,2
3,2

kW
0,25
0,45
0,75
0,75

220 V

MXPM 401-60
MXPM 402-60/A

A
2,8
6,2

Q
HP
0,34
0,6
1
1

P2
IA/IN kW
2,7 0,33
3,2 0,75
1,1

l/min

H m

HP
0,45
1
1,5

m3/h

0
0
16,5
32
48,5
64

16,6

33,3

15,2 13,5
29,5 26,5
45 40,5
58,5 52

50

66,6

83,3

100

11,5
22,5
34,5
45

9
18
28,5
36,5

6,2
13
21,5
27

3
7
12,5
16,5

m3/h

2,5

l/min

41,6

66,6

83,3

100

116

133

16,3

14,5

13
27
39

11
24,5
35

9,2
21,5
30

7
17,5
24

4
12,5
17

H m 32,5 29,5

Test results with clean cold water, without gas content.


+ 0,5 m security margin on NPSH-value is necessary.

48,5

44

Tolerances according to ISO 9906, annex A.


For capacities over 4 m3/h use a suction pipe G 1 1/4 (DN 32).

Dimensions and weights


f
115

161

G1

mm

116

177
h3

MXP 201-60 - MXPM 201-60


MXP 202-60 - MXPM 202-60
MXP 203-60/A - MXPM 203-60/A
MXP 204-60/A - MXPM 204-60/A
MXP 401-60 - MXPM 401-60
MXP 402-60/A - MXPM 402-60/A
MXP 403-60/A

95

10

4.93.281

33
210

kg

TYPE

ISO 228

G1

ISO 228

30

112
w

146

f
362
362
391
391
362
391
391

h3
176
176
192
192
176
192
192

w
102
102
112
112
102
112
112

MXP
5,9
7,2
9,5
9,6
5,9
9,4
11

MXPM
5,9
7,2
10,5
10,6
5,9
10,4

Features

Extra safety
against running dry, with the suction port above
pump axis.
Robust
Single-piece barrel casing.
Compact
Single-piece lantern bracket and base.
Low noise
with the water-filled shroud around the stages.
3.93.123

78

MGP 60 Hz

Horizontal Multi-Stage Close Coupled Pumps


Construction
Horizontal multi-stage close coupled pump.
Single-piece barrel casing in cast iron, with front suction port above pumps axis and radial delivery at top.
Stages in Noryl.

Applications
For water supply.
For domestic use, for garden use and irrigation.

Operating conditions
Liquid temperature: 0 C to +50 C.
Ambient temperature up to +40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Materials

Motor

Component

Material

Pump casing

Cast iron GJL 200 EN 1561

Casing cover

Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Pump Shaft

Chrome steel 1.4104 EN 10088 (AISI 430)

Stage casing

PPO-GF20 (Noryl)

Impeller

PPO-GF20 (Noryl)

Mechanical seal

Carbon - Ceramic - NBR

2-pole induction motor, 60 Hz (n = 3450 rpm).


MGP:
three-phase 220/380 V.
MGPM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

Characteristic curves n = 3450 rpm


0
70

Imp. g.p.m. 5

10

15

0
50

20

Imp. g.p.m.

H
60

200

MGP 204-60

10

20
150

MGP 403-60

m
40

ft

50

MGP 203-60

150

m
40

MGP 402-60

30

100

ft

MGP 202-60

30

100

20

MGP 401-60
20

MGP 201-60

50

50

10

10
0
0
m3/h 1
Q l/min 20
0
45
40

2
40

60

0
6
100
4

5
80

0
0
55

NPSH
m

NPSH

30
25
0

Q m3 /h 1

72.1138

79

6
100

50

NPSH

50

NPSH
m
3

40

35
0

m3/h

Q l/min

m3/h

72.1139

1
8

MGP 60 Hz

Horizontal Multi-Stage Close Coupled Pumps

Performance n 3450 rpm


220 V 380 V

3~

MGP 201-60
MGP 202-60
MGP 203-60/A
MGP 204-60/A

A
1,7
3,1
4,2
4,2

A
1
1,8
2,4
2,4

IA/IN
4,7
4,8
4,8
4,8

MGPM 201-60
MGPM 202-60
MGPM 203-60/A
MGPM 204-60/A

220 V 380 V

3~
MGP 401-60
MGP 402-60/A
MGP 403-60/A

A
2
4,2
5,4

A
1,2
2,4
3,1

220 V

1~

1~
IA/IN
4
4,8
4,2

P1 Max. power input.


IA/IN = D.O.L. starting current / Rated current

A
2,3
4,1
6,2
6,2

P2
kW
0,25
0,45
0,75
0,75

IA/IN
1,8
2,7
3,2
3,2

220 V

MGPM 401-60
MGPM 402-60/A

HP
0,34
0,6
1
1

P2
IA/IN kW
2,7 0,33
3,2 0,75
1,1

A
2,8
6,2

l/min

16,6

33,3

50

66,6

83,3

100

11,5
22,5
34,5
45

9
18
28,5
36,5

6,2
13
21,5
27

3
7
12,5
16,5

H m

HP
0,45
1
1,5

m3/h

m3/h
l/min

H m

Test results with clean cold water, without gas content.


+ 0,5 m security margin on NPSH-value is necessary.

16,5
32
48,5
64
0

15,2 13,5
29,5 26,5
45 40,5
58,5 52
2,5

41,6

66,6

83,3

100

116

133

16,3
32,5
48,5

14,5
29,5
44

13
27
39

11
24,5
35

9,2
21,5
30

7
17,5
24

4
12,5
17

Tolerances according to ISO 9906, annex A.


For capacities over 4 m3/h use a suction pipe G 1 1/4 (DN 32).

Dimensions and weights


f
115
G1 ISO 228

161

mm

kg

4.93.367

95
210

10

33
8

9
112

146

30

h3

161

116

ISO 228

G1

TYPE
MGP 201-60 - MGPM 201-60
MGP 202-60 - MGPM 202-60
MGP 203-60/A - MGPM 203-60/A
MGP 204-60/A - MGPM 204-60/A
MGP 401-60 - MGPM 401-60
MGP 402-60/A - MGPM 402-60/A
MGP 403-60/A

Features

Extra safety
against running dry, with the suction port above
pump axis.
Robust
Single-piece barrel casing.
Compact
Single-piece lantern bracket and base.
Low noise
with the water-filled shroud around the stages.

80

f
362
362
391
391
362
391
391

h3
176
176
192
192
176
192
192

w
102
102
112
112
102
112
112

MGP MGPM
8,9
9
10,2
10,2
13,5
12,5
12,6
13,6
8,9
9
13,4
12,4
14

MXSU

60 Hz

Vertical multi-stage close coupled pumps


Construction
Vertical multi-stage close coupled pumps in chrome-nickel
stainless steel, with motor shields in brass.
Suction connection on the lower casing and delivery connection on the top casing. Motor cooled by the pumped water passing between the motor jacket and the external jacket.
Double mechanical shaft seal with interposed oil chamber.

Applications
For clean water without abrasives or additives aggressive for
the materials of the pump.
For domestic, civil and industrial applications.
For installation in confined space with minimum ventilation.
For installation in locations subject to risk of temporary
flooding.
For installation in areas exposed to water jetting.
When low-noise operation is required.

Operating conditions
Water temperature up to 35 C.
Maximum permissible pressure in the pump casing: 10 bar.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
MXSU : three-phase 220 V;
three-phase 380 V.
MXSUM : single-phase 220 V, with thermal protector.
Control box with capacitor, on request (only for 220 V).
Cable: H07RN-F, 4 G 1 mm2, length 2 m.
Insulation class F.
Protection IP 68.
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: IEC 335-2-41, EN 60335-2-41.

Materials
Components
External jacket
Suction casing
Stage casing
Impeller
Oil chamber cover
Spacer sleeve
Motor jacket
Shaft
Motor shield
Elbow
Upper mechanical seal
Lower mechanical seal
Seal lubrication oil

Material

Chrome-nickel steel AISI 304

Chrome-nickel steel AISI 303


Brass P- Cu Zn 40 Pb 2 UNI 5705
Brass P- Cu Zn 40 Pb 2 UNI 5705 nickel-plated
Steatite, carbon, NBR
Ceramic alumina, silicon carbide, NBR
Oil for food machinery and pharmaceutic use

Special features on request


- Other voltages.

Coverage chart n = 3450 rpm


0 U.S. g.p.m. 5
0

10
5

Imp. g.p.m.

15

0 U.S. g.p.m. 10

20

10

15

Imp. g.p.m.

20

30

10

20

40
30

60

70

MXSU 204-60

MXSU 2

60

50

200

MXSU 403-60

150

40

MXSU 203-60

Hm

MXSU 4

50

150

ft

Hm

40

ft

30

30

100

20

MXSU 402-60

100

50
10

20
50
10

0
0

m3/h

Q l/min

2
20

30

40

3
50

4
60

5
70

80

50

60

30

40

20

30

m3/h

0
0

Q l/min

Q m3/h

3
40

60

5
80

6
100

7
120

9
140

20

10
0

Q m3/h

72.588/1

81

10
160

72.589/1

10

MXSU

60 Hz

Vertical multi-stage close coupled pumps

Performance n 3450 rpm


220 V 380 V

3~

220 V Capacitor

1~

IA/IN

MXSU 203-60

4,1

2,4

3,2

MXSU 204-60

4,8

2,8

3,75 MXSUM 204-60

MXSUM 203-60

220 V 380 V

3~

IA/IN

kW

HP

20

450

3,3

0,75

25

450

3,3

0,9

1,2

P2

IA/IN

kW

HP

2,8 3,75 MXSUM 402-60

25

450

3,3

0,9

1,2

3,2

25

450

3,3

1,1

1,5

MXSU 402-60

4,8

MXSU 403-60

5,6

IA/IN
3,2

MXSUM 403-60

P2 Rated motor power output.


IA/IN = D.O.L. starting current / Rated current

1,5

2,5

3,5

4,5

l/min

Hm

16,6 25 33,3 41,6 50 58,3 66,6 75 83,3

64,5 61

59

56 52,7 49

3,5

45 40,3 35,3 30

m3/h

2,5

l/min

41,6 50 58,3 66,6 83,3 100 116 133 150

Hm

30,5 28 27,5 27 26
46 42,5 41,5 40,5 39

21

32 27,5 22 16,5

18 14,5 11

18

kg

MXSU(M) 203-60

10.4

12.4

MXSU(M) 204-60

12.1

13.9

MXSU(M) 402-60

11.1

12.9

MXSU(M) 403-60

11.7

13.4

72

32

G 1 1/4
ISO 228

524

MXSU MXSUM

4.93.179

90
45

60

165

149

190

Control box for single-phase pumps (on request)


Pg 11

200

75

76

Pump

Control Capacitor
box
with
pump 450 Vc

MXSUM 203-60

QM 11

20 F

QM 12

25 F

MXSUM 204-60
MXSUM 402-60
MXSUM 403-60
Pg 11

Weights kg 0,4
3.94.053

82

36

Weights
13

24

Features

Pump

48,5 46 44,3 42 39,5 36,8 33,8 30,2 26,5 22,5

Test results with clean cold water, without gas content.


Tolerances according to ISO 9906, annex A.

Dimensions and weights


G 1 1/4 ISO 228

6,5

220 V Capacitor

1~

m3/h

P2

MXV-B

Vertical Multi-Stage
Close Coupled Pumps

60 Hz

Construction
Vertical multi-stage close coupled pumps with suction
and delivery connections of the same diameter and arranged along the same axis (in-line).
All parts that come into contact with the liquid, including
wet-end covers, are in chrome-nickel stainless steel with
corrosion-resistant bearing sleeves lubricated by the
pumped liquid.

Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or abrasive matter and non-aggressive for stainless
steel (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressureboosting systems, fire-extinguishing systems, high-pressure washing plants, irrigation, agricultural uses and
sport installations.

Operating conditions
Temperature of liquid: from -15 C to +90 C.
Operating environment temperature: up to 40 C.
Maximum permissible pressure in pump casing: 16 bar.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
MXV-B: three-phase 220/380 V.
MXV-BM: single-phase 220 V,
with thermal protector up to 1,1 kW.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Pump casing seal rings in FPM.
- Higher or lower liquid or ambient temperatures.
- Flanges to screw, in chrome-nickel steel.

Coverage chart n 3450 rpm


5
4

U.S. g.p.m. 10
5 Imp. g.p.m.

20

Materials (wetted parts)

30

10

20

40
30

50
40

Component

100
50

100

120

MXV-B
100
300
H

25-2..

200

32-4..

40-8..

50

50-18..
H

40

ft
100

30

External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve
Pump shaft
Plug
Mechanical seal
ISO 3069 - KU
Wear ring
O-ring

Material

Chrome-nickel steel
1.4301 EN 10088 (AISI 304)

Chrome-nickel steel
1.4305 EN 10088 (AISI 303)
Ceramic alumina/Carbon/EPDM
PTFE
NBR

Designation
20

15

2
m3/h
Q
20 l/min 30

40

3
50

5
100

10
150
200

50
20
30
300
400 500
72.1002/1

83

Series
Single-phase motor (up to 1,5 kW)
DN ports in mm
Rated capacity in m3/h
Number of stages
Frequency 60 Hz

MXV-B M 25-205-60

10

MXV-B

25-2

Vertical Multi-Stage
Close Coupled Pumps

60 Hz

Characteristic curves and performance n 3450 rpm


0

U.S. g.p.m.

Imp. g.p.m.

10
5

15

20

10

15

120

MXV-B 25-207-60

100

300

ft

200

80

m
60

3
40
100
20

0
0

m3/h
l/min

2
20

30

40

3
50

4
60

70

80
0.5

50

0.4

Pst

0.2

20

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

Pst
kW

30

10
4

0.1

Head and power values valid for liquids with


density = 1,0 kg/dm 3 and kinematic viscosity
= max 20 mm2/sec.

10

NPSH
m
2

ft

Pst = Power with reference to one stage.


P2 Rated motor power output.
0

m3/h

3~

220 V 380 V

1~

72.1134

P2

220 V

IA/IN = D.O.L. starting current / Rated current

m3/h

1,5

2,5

3,5

4,5

l/min

33,3

41,6

50

58,3

66,6

75

83,3

IA/IN

16,6

25

MXV-B 25-203-60

4,5

2,6

5,2

MXV-BM 25-203-60 6,5

2,9

0,75

49,9

47,8

46,2

44

41,8

39

35,8

32,1

28,3

24,1

MXV-B 25-204-60

5,7

3,8

5,3

MXV-BM 25-204-60 8,5

1,1

1,5

65

62

60,3

57,8

54,9

51,5

47,6

43,2

38,4

33

MXV-B 25-205-60

5,2

MXV-BM 25-205-60 10,6

3,8

1,5

81,5

78

75,4

72,3

68,6

64,4

59,5

54

48

41

5,9

2,2

98

94

90,5

86,7

82,3

77,2

71,4

64,8

57,6

49

5,9

2,2

114

110

105,6 101,2

96

90,1

83,3

75,5

67

57

MXV-B 25-206-60 10,7 6,2


MXV-B 25-207-60 10,7 6,2

IA/IN kW

HP

Hm

84

MXV-B

Vertical Multi-Stage
Close Coupled Pumps

60 Hz

32-4

Characteristic curves and performance n 3450 rpm


0

U.S. g.p.m.

Imp. g.p.m.

10

20

30

10

40

20

30

120

MXV-B 32-407-60
100

300
m

80

10

ft

60

200

3
40
100
20

0
0

m3/h
l/min

3
40

5
80

60

60

6
100

7
120

9
140

10
160

0.4
Pst
kW

40
Pst

30

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

0.2

20
4

0.1

Head and power values valid for liquids with


density = 1,0 kg/dm 3 and kinematic viscosity
= max 20 mm2/sec.

10

NPSH
m
2

ft

Pst = Power with reference to one stage.


P2 Rated motor power output.
0
0

IA/IN = D.O.L. starting current / Rated current

3~

m3/h

220 V 380 V

1~

9 72.1135 10

220 V

m3/h

P2

2,5

3,5

41,6

50

58,3

66,6

83,3

100

116

133

150

1,5

50,5

47

46,2

45,2

44

41,5

38

34

28,4

22

65

61

60

58,2

56,8

53,4

49,2

43,8

37

29

82

76

74,3

72,7

71

66,8

61,5

54,7

46,3

36

97

91

89,1

87,3

85,2

80,1

73,8

65,7

55,5

43

114

106

104

102

99,4

93,5

86,1

76,6

64,8

50

IA/IN

5,7

3,3

5,3

MXV-B 32-404-60 10,7 6,2


MXV-B 32-405-60 10,7 6,2

5,9

A IA/IN kW
1,1
3
MXV-BM 32-403-60 8,5
2,2

5,9

2,2

MXV-B 32-406-60 10,7 6,2


MXV-B 32-407-60
7,5

5,9

2,2

9,5

MXV-B 32-403-60

Q
HP

l/min

Hm

85

MXV-B

40-8

Vertical Multi-Stage
Close Coupled Pumps

60 Hz

Characteristic curves and performance n 3450 rpm


U.S. g.p.m.

20

30

0 Imp. g.p.m.

20

40

50

30

60

40

50

120
110
350
100

MXV-B 40-806-60

300

90
80

250

5
70

ft

60
50

200

150

40
100

30
20

50
10

0
0

m3/h
l/min

50

10

100

15

150

200
0.8

70
Pst

Pst
kW

50

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

0.4

40

0.2

30
5

Head and power values valid for liquids with


density = 1,0 kg/dm 3 and kinematic viscosity
= max 20 mm2/sec.

15

4
NPSH
m 3

ft
10

Pst = Power with reference to one stage.


P2 Rated motor power output.

2
5
1

m /h

3~

10

220 V 380 V
A

P2

72.587/1

15

IA/IN = D.O.L. starting current / Rated current

m3/h

6,5

10

11

12

13

14

15

l/min

108

133

150

166

183

200

216

233

250

IA/IN

kW

HP

9
5,2
MXV-B 40-804-60 10,7 6,2
MXV-B 40-805-60
7,5

1,8

2,5

51,8

46,5

44,2

42,4

40,8

38,3

35,5

32

28

23

5,9

2,2

69

62

59

56,5

54,4

51

47,3

42,6

37,3

30,6

9,5

84

75

72,5

70

67

63,5

60

55,5

50

43

MXV-B 40-806-60

9,8

5,5

101

90

87

84

80

76,5

72

66,5

60

51,5

MXV-B 40-803-60

11,3

Hm

86

MXV-B

50-18

Vertical Multi-Stage
Close Coupled Pumps

60 Hz

Characteristic curves and performance n 3450 rpm


U.S. g.p.m.

40

0 Imp. g.p.m.

60
40

80

100

60

120

80

100
400

120

MXV-B 50-1807-60

110
350
100

m
90

80

300
ft

250

200

10

70
60
50

150

40

30

100

20
50
10
0

0
0

m3/h
l/min 100

10

20

200

300

70

30
500

400

1,6

Pst
kW

40

0.4

30
8

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

20
ft

Head and power values valid for liquids with


density = 1,0 kg/dm 3 and kinematic viscosity
= max 20 mm2/sec.

Pst

50

0.8

6
NPSH
m 4

10

Pst = Power with reference to one stage.


P2 Rated motor power output.

2
0

10

m3/h

3~

20

220 V 380 V

m3/h

P2

A
A IA/IN
MXV-B 50-1802-60 10,7 6,2 5,9
7,5 9,5
MXV-B 50-1803-60
11,3 9,8
MXV-B 50-1804-60

IA/IN = D.O.L. starting current / Rated current

72.587/1

30

12

15

18

21

24

27

kW

HP

100

150

200

250

300

350

400

450

2,2

35

33

31,8

30,2

28,3

26

23,5

20

15,8

52,5

49,5

47,7

45,3

42,5

39

35,2

30

23,7

5,5

70

66

63,6

60,4

56,6

52

47

40

31,6

87,5

82,5

79,5

75,5

70,7

65

58,7

50

39,5

l/min

Hm

MXV-B 50-1805-60

14,5

8,2

5,5

7,5

MXV-B 50-1806-60

14,5

8,2

5,5

7,5

105

99

95,4

90,6

84,9

78

70,5

60

47,4

MXV-B 50-1807-60

18,2

9,5

7,5

10

123

116

113

106

99

91

82,2

70

55,3

87

MXV-B

60 Hz

Vertical Multi-Stage
Close Coupled Pumps

Dimensions and weights


SM

kW

h2

(3)

G
4.93.298

L1

m1

(2)

m2

25

h1

(1)

s
n2
n1

mm

Motor
P2

Pump

HP

Net weight

MXV-B MXV-BM
kg
kg

L1

h1

h2

SM

m1

m2

n1

n2

G1
G1
G1
G1
G1

215
215
215
215
215

75
75
75
75
75

564
564
588
612
636

130
130
130
130
130

210
210
210
210
210

180
180
180
180
180

150
150
150
150
150

100
100
100
100
100

12,5
12,5
12,5
12,5
12,5

23,5
24,5
27,5
29
30

24,5
25,5
28,5

25,5

ISO 228

MXV-B(M) 25-203-60
MXV-B(M) 25-204-60
MXV-B(M) 25-205-60
MXV-B
25-206-60
MXV-B
25-207-60

0,75 1
1,1 1,5
1,5
2
2,2
3
2,2
3

MXV-B(M) 32-403-60
MXV-B
32-404-60
MXV-B
32-405-60
MXV-B
32-406-60
MXV-B
32-407-60

1,1
2,2
2,2
2,2
3

1,5
3
3
3
4

G 11/4
G 11/4
G 11/4
G 11/4
G 11/4

215
215
215
215
215

75
75
75
75
75

564
564
588
612
699

130
130
130
130
128

210
210
210
210
210

180
180
180
180
180

150
150
150
150
150

100
100
100
100
100

12,5
12,5
12,5
12,5
12,5

24,5
28
29
31
40

MXV-B
MXV-B
MXV-B
MXV-B

40-803-60
40-804-60
40-805-60
40-806-60

1,8
2,2
3
4

2,5
3
4
5,5

G 11/2
G 11/2
G 11/2
G 11/2

225
225
225
225

80
80
80
80

593
593
686
716

130
130
128
128

246
246
246
246

215
215
215
215

190
190
190
190

130
130
130
130

14
14
14
14

29
31,5
41
47

MXV-B
MXV-B
MXV-B
MXV-B
MXV-B
MXV-B

50-1802-60
50-1803-60
50-1804-60
50-1805-60
50-1806-60
50-1807-60

2,2
3
4
5,5
5,5
7,5

3
4
5,5
7,5
7,5
10

G2
G2
G2
G2
G2
G2

250
250
250
250
250
250

90
90
90
90
90
90

595
663
701
766
803
841

130
128
128
160
160
160

246
246
246
246
246
246

215
215
215
215
215
215

190
190
190
190
190
190

130
130
130
130
130
130

14
14
14
14
14
14

30,6
40
43,5
55
62,5
63,5

(1) Filling
(2) Draining
(3) Standard position of terminal box
(for other positions rotate motor through 90 or 180)

Features
Wider Range of Application
All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel stainless steel.
With corrosion-resistant seal rings and guide ring.

Low Cost Installation


Vertical construction with reduced pump height for installation in small
spaces.
In-line connections to simplify the piping layout with the possibility of
inserting the pump in straight pipe-lines.
Disassembly, inspection or cleaning of internal parts without removal
of piping.

99.00

61.04

46.00

14.20

34.02

20.00

Robust and Reliable

14.06

25.05

The suction and discharge nozzles arranged in-line absorb the forces
of the piping on the pump without the creation of distorting loads
causing local friction and early wears.
The lantern brackets compact and robust design maintains a sure
alignment between rotating and fixed parts, reducing vibration.
The upper cover design prevents entrapment of air around the
mechanical seal.

14.04

36.51

36.00

61.02

36.52

14.02

64.15

28.00

64.19

25.02

64.10

25.03

22.12

25.01

28.08

14.54

28.04

16.00

14.20

34.01

Low-Noise Operation
The water filled shroud around the stages and thick external walls,
work together for low-noise operation.

14.12

61.00
3.93.127

88

(1)

MXV

60 Hz

Vertical Multi-Stage In-Line Pumps


Construction
Vertical multi-stage pumps with suction and delivery connections
of the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped
liquid.
A pump with thrust bearing and sleeve coupling for use of any
standard motor with V1 construction.

Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting
systems, fire-extinguishing systems, high-pressure washing
plants, irrigation, agricultural uses and sport installations.

Operating conditions
Temperature of liquid: from -15 C to +110 C.
Operating environment temperature: up to 40 C.
Maximum permissible pressure in pump casing: 25 bar.

Motor
Standard-type: 2-4 pole induction motor, 60 Hz.
Classification scheme EFF2 or EFF1 (High efficiency) on request.
Construction IM V1 (IEC 34-7).
Insulation class F (IEC 85).
Protection IP 55 (IEC 529).
three-phase with rated voltage: up to 3 kW 220/380 V (IEC 38);
from 4 kW 380/660 V (IEC 38).
Rated speed of rotation (60 Hz): MXV = 3450 rpm
MXV4 = 1750 rpm.

MXV 25-2, 32-4, 40-8

MXV 50-16, 65-32, 80-48

All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel stainless steel AISI 304.

Internal parts in contact with the liquid in chrome-nickel stainless steel,


AISI 304 with pump casing and upper cover in cast iron.

Materials (wetted parts)

Materials (wetted parts)

Pos. Nr.
(pag.104)

Pos. Nr.
(pag.104)

13.60
14.02
16.00
20.00
25.02
28.00
34.01
34.02
64.15
64.00
64.10
25.03
36.00
14.54

Component
Flange
External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing
Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Material

Component

14.00 Pump casing


34.02 Upper cover
Chrome-nickel steel
1.4301 EN 10088 (AISI 304)

14.02
25.02
28.00
64.15
64.00

Chrome-nickel steel
1.4305 EN 10088 (AISI 303)
Corrosion-resistant, cemented carbide
Ceramic alumina

64.10
25.03
36.00

Hard metal/Carbon/EPDM.

14.54

PTFE
NBR

External jacket
Stage casing
Impeller
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing
Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

A (standard)
Cast iron
GJL 250 EN 1561
Chrome-nickel steel
1.4301 EN 10088 (AISI 304)
Chrome-nickel steel
1.4305 EN 10088 (AISI 303)
Corrosion-resistant, cemented carbide
Ceramic alumina
Hard metal/Carbon/EPDM

PTFE
NBR

Direction of rotation: clockwise as seen from the motor.

Direction of rotation: anticlockwise as seen from the motor.

Variants (to be specified when ordering)

Variants (to be specified when ordering)

Pump with threaded ports (G).


Pump with flanged ports (F).
Pump without motor.
Pump with standard motor.

Pump without motor.


Pump with standard motor.

Other variants (on request)

Other variants (on request)

O-rings FPM.
Other mechanical seal.
Pump with motor of Client's choice (if available).
Other voltage ratings.
Pump with support feet for horizontal installation (H1 or H2).
Support feet for horizontal installation, set.
Welding counter-flanges, PN 25 (steel).

With counter-flanges in chrome-nickel steel.


O-rings FPM.
Other mechanical seal.
Pump with motor of Client's choice (if available).
Single-phase motor 220 V, up to 2.2 kW.
Other voltage ratings.

Higher or lower liquid or ambient temperatures.

Higher or lower liquid or ambient temperatures.


89

11

MXV

Vertical Multi-Stage In-Line Pumps

MXV 25-2, 32-4, 40-8

MXV 50-16, 65-32, 80-48

Designation

Designation
MXV 25-205-60

G *

MXV 50-1605-60

Series
DN ports in mm
Rated capacity in m3/h (n = 3450 rpm)
Number of stages
Frequency 60 Hz

Series
DN ports in mm
Rated capacity in m3/h (n = 3450 rpm)
Number of stages
Frequency 60 Hz

Construction variants
special seal code (no code = standard seal)
threaded ports
flanged ports
with motor (or without motor)
* with no further designation = with standard motor

Construction variants
special seal code (no code = standard seal)
materials combination: A (standard)
with support feet for horizontal installation H, variant 1
with motor (or without motor)
* with no further designation = with standard motor

G
F

A H1 *

Installations

Pipe connection

Vertical installation
(Standard).

4.93.213/1

4.93.213/2

4.93.213/3

4.93.213/4

3.93.013

Pump with threaded ports:


pipes screwed into the ports

Pump with threaded ports:


pipes with union couplings
(locally available)

Horizontal installation.

Pump with flanged ports:


pipes with counter-flanges

Pump size

Number
of stages

Stage casings
with bearing

40 - 803
40 - 804
40 - 805
40 - 806
40 - 807
40 - 808
40 - 810

3
4
5
6
7
8
10

1
1
1
1
1
1
1

40 - 811

11
12
13
14
15
16
18

2
2
2
2
2
2
2

17
19
20

3
3
3

MXV - MXV4
32 - 403
32 - 404
32 - 405
32 - 406
32 - 407
32 - 408
32 - 410

25 - 212

32 - 412

25 - 214

32 - 414

25 - 216
25 - 218

32 - 416
32 - 418

40 - 813
40 - 815

40 - 817
40 - 819
25 - 220

Variant H2:
suction on the right,
delivery on the left.

Variable parts

Variable parts

25 - 203
25 - 204
25 - 205
25 - 206
25 - 207
25 - 208
25 - 210

Variant H1:
suction on the left,
delivery on the right.

Pump size

Number
of stages

Stage casings
with bearing

80 - 4801
80 - 4802
80 - 4803
80 - 4804
80 - 4805

1
2
3
4
5
6
7
8
9
10

1
1
1
1
1
1
1
1
1
1

80 - 4806
80 - 4807
80 - 4808

6
7
8
9
10
11
12
14
16

2
2
2
2
2
2
2
2
2

MXV - MXV4

50 - 1603
50 - 1604
50 - 1605
50 - 1606
50 - 1607
50 - 1608
50 - 1609
50 - 1610

65 - 3202
65 - 3203
65 - 3204
65 - 3205
65 - 3206
65 - 3207

65 - 3208
65 - 3209
65 - 3210
50 - 1611
50 - 1612
50 - 1614
50 - 1616

90

65 - 3212

MXV

60 Hz

Vertical Multi-Stage In-Line Pumps

Coverage chart
5

U.S. g.p.m.

10

Imp. g.p.m.

30

20
20

10

40

50

30

100

40

300

200

50

100

400
300

200

300

900

200

MXV

n 3450 rpm

ft
500

H
m

400

MXV 25

MXV 32

MXV 40

MXV 65

MXV 50

100
300

200

MXV 80
50
40
100

30

20

15

m3/h

1
20

Q l/min

2
30

40

3
50

10

5
100

150

20
200

300

30
500

400

40

50

50
60 70 80 90 100
1500
1000
72.1002

3
2

U.S. g.p.m.
5

10

Imp. g.p.m.

20

30

10

20

40

50

30

40

100
50

150
100

100

300

MXV4

n 1750 rpm

200

50

40

ft
100

30

MXV4 25

MXV4 32

MXV4 40

MXV4 50

MXV4 65

20

MXV4
80

50
40

10
30

20
5
0.5
10

m3/h
l/min

2
20

30

40

3
50

10
100

150

20
200

300

400

30
500

40
600
72.1002/1

91

11

MXV 25-2

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 3450 rpm


0

U.S. g.p.m.

Imp. g.p.m.

10
5

Dimensions and weights


20

15

SM

10

15

240

MXV 25-214-60

700
FM

200

12

180

MXV
without
motor

600

h3

ft
160

10

MXV
with motor

(3)

(1)

(1)

500

h2

140

120

400

G1

G1

DN 25

DN 25

7
100

300

60

3.93.011

20

80

75

75

(2)

215

3.93.011/1

MXV (G)
threaded
ports

(2)

250

MXV (F)
flanged
ports

200

3
40
180 210

100
20

0
0

m3/h
l/min

2
20

30

3
50

40

4
60

100

80
0.5

50

Pst
kW

30

Counterflanges

0.2

Pst

10
4

Flanges

in stainless steel

EN 1092-2
PN 25-40

43

0.1

14

10

NPSH
m
2

150

0.4

20

(1) Filling
(2) Draining
(3) Standard position of terminal box.
(for other positions rotate motor through 90 or 180)

12,5

5
70

DN 25

115
85
65
25

G1

ft

m3/h

72.585/1

(4) With standard motor


(5) Weight MXV (G) = weight MXV (F) - 1kg
(6) Net weight pump with standard motor

Performance
Pump type

Motor
power

Motor
size

m3/h

1,5

l/min

16,6

25

2,5

3,5

33,3 41,6

50

58,3 66,6

Dimensions
mm

4,5

75

83,3

h2

M (4)

h3

FM

38,6 35,7 32,4 28,7 24,5

Pump weight
without with
motor motor
SM (4) kg (5) kg (6)

kW

HP

MXV 25-203-60

1,1

1,5

80 B

49

47

45,3 43,4

372

234

606

200

120

19

29

MXV 25-204-60

1,1

1,5

80 B

65

62

60,3 57,8 54,9 51,5 47,6 43,2 38,4

33

372

234

606

200

120

19

29

MXV 25-205-60

1,5

90 S

81,5

78

75,4 72,3 68,6 64,4 59,5

41

406

282

688

200

128

21

34

MXV 25-206-60

2,2

90 L

98

94

90,5 86,7 82,3 77,2 71,4 64,8 57,6

49

430

282

712

200

128

22

38

MXV 25-207-60

2,2

90 L

114

110 105,6 101,2

57

454

282

736

200

128

23

39

MXV 25-208-60

100 L

131

125 120,6 115,6 109,8 103

65

488

313

801

250

135

25

48

MXV 25-210-60

100 L

163

156 150,8 144,5 137,2 128,7 119

82

536

313

849

250

135

26

49

MXV 25-212-60

5,5

112 M

196

188

181 173,4 164,6 154,4 142,8 129,6 115,2

98

584

334

918

250

148

28

58

MXV 25-214-60

5,5

112 M

229

219

211

114

632

334

966

250

148

29

59

H
m

Head and power values valid for liquids with density


3
2
= 1.0 kg/dm and kinematic viscosity = max 20 mm/sec.
Pst = Power with reference to one stage.

202

41

96

192

54

90,1 83,3 75,5

180

48
67

95,2 86,4 76,8

167

108
151

96
134

Test results with clean cold water, without gas content.


A safety margin of + 0.5 m is recommended for the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

92

MXV 32-4

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 3450 rpm


0

U.S. g.p.m. 10

Imp. g.p.m.

20

Dimensions and weights

30

10

40

20

SM

30

240

MXV 32-414-60

700
FM

200

12

180

MXV
without
motor

600
ft

h3

160

(1)

(1)

500

10

MXV
with motor

(3)

11

h2

140
400

120

G 1 1/4

G 1 1/4

DN 32

DN 32

7
100
300

5
4

60

3.93.011

20

80

75

75

(2)

215

3.93.011/1

MXV (G)
threaded
ports

(2)

250

MXV (F)
flanged
ports

200

3
40
180 210

100
20

0
0

m3/h
l/min

3
40

60

60

5
80

6
100

7
120

9
140

10

100

160

150

(1) Filling
(2) Draining
(3) Standard position of terminal box.
(for other positions rotate motor through 90 or 180)

12,5

0.4
Pst
kW

40
Pst
30

0.2

20
4

0.1

Counterflanges

Flanges

in stainless steel

EN 1092-2
PN 25-40

43
19

10

NPSH
m
2

ft

0
0

(4) With standard motor


(5) Weight MXV (G) = weight MXV (F) - 1kg
(6) Net weight pump with standard motor

9 72.586/1 10

G 1 1/4

DN 32

0
m3/h

140
100
76
32

Performance
Pump type

Motor
power

Motor
size

m3 /h

2,5

3,5

l/min

41,6

50

58,3 66,6 83,3

kW

HP

MXV 32-403-60/A 1,5


2,2
MXV 32-404-60

2,2

90 S

90 L

65

61

49,2 45,6 44,6 43,6 42,6


60

40

Dimensions
mm

Pump weight
without with
motor motor
SM (4) kg (5) kg (6)

100 116,6 133,3 150

h2

M (4)

h3

FM

27,8 21,6

382

282

664

200

128

21

34

29

382

282

664

200

128

21

37

37

33

58,2 56,8 53,4 49,2 43,8

37

MXV 32-405-60

2,2

90 L

82

76

74,3 72,7

66,8 61,5 54,7 46,3

36

406

282

688

200

128

22

38

MXV 32-406-60

100 L

97

91

89,1 87,3 85,2 80,1 73,8 65,7 55,5

43

440

313

753

250

135

25

48

MXV 32-407-60

100 L

114

106

104 101,8 99,4 93,5 86,1 76,6 64,8

50

464

313

777

250

135

26

49

MXV 32-408-60

5,5

112 M

130

121 118,9 116,3 113,6 106,9 98,4 87,5 74,1

57

488

334

822

250

148

27

57

MXV 32-410-60

5,5

112 M

163

151 148,6 145,4 142 133,6 123 109,4 92,6

71

536

334

870

250

148

28

58

MXV 32-412-60

5,5

7,5

132 SA

195

181 178,3 174,5 170,4 160,3 147,6 131,3 111,1

85

604

374

978

300

167

32

75

MXV 32-414-60

5,5

7,5

132 SA

228

212

208 203,6 198,8 187 172,2 153,2 129,6 100

652

374

1026

300

167

34

77

H
m

Head and power values valid for liquids with density


3
2
= 1.0 kg/dm and kinematic viscosity = max 20 mm/sec.
Pst = Power with reference to one stage.

71

Test results with clean cold water, without gas content.


A safety margin of + 0.5 m is recommended for the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

93

MXV 40-8

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 3450 rpm


U.S. g.p.m.

20

30

0 Imp. g.p.m.

40

20

Dimensions and weights


50

30

60

40

SM

50

200

600

180

MXV 40-811-60
FM

500

10

140

(3)

MXV
without
motor

160

ft

h3
(1)

(1)

120

400

h2

G 1 1/2

100

6
80

G 1 1/2

DN 40

DN 40

300
80

80

5
3.93.011

20

60

MXV
with motor

(2)

225

200

3.93.011/1

MXV (G)
threaded
ports

(2)

280

MXV (F)
flanged
ports

3
40
100

215 246

20

0
0

m3/h
l/min

5
50

100

150

130

200

190

0.8

70
Pst

Pst
kW

50

(1) Filling
(2) Draining
(3) Standard position of terminal box.
(for other positions rotate motor through 90 or 180)

14

15

10

0.4

40

0.2

30
5

Counterflanges

Flanges

in stainless steel

EN 1092-2
PN 25-40

43

4
NPSH
m 3

19

15
ft
G 1 1/2

DN 40

10

150
110
84
40

2
5
1

m3/h

10

72.587/1

(4) With standard motor


(5) Weight MXV (G) = weight MXV (F) - 1kg
(6) Net weight pump with standard motor

15

Performance
Pump type

Motor
power
kW

MXV 40-803-60/A 2,2


3
MXV 40-804-60

Motor
size

m3/h

l/min

6,5

10

11

12

13

14

Dimensions
mm

15

108,3 133,3 150 166,6 183,3 200 216,6 233,3 250

h2

M (4)

Pump weight
without with
motor motor
SM (4) kg (5) kg (6)

h3

FM

90 L

50,4

45

43,5

42

40

38

36

33,3

30

25,8

421

282

703

200

128

25

41

100 L

67

60

58

56

53,5

51

48

44,5

40

34,5

421

313

734

250

135

25

48

HP

MXV 40-805-60

5,5

112 M

84

75

72,5

70

67

63,5

60

55,5

50

43

451

334

785

250

148

26

56

MXV 40-806-60

5,5

112 M

101

90

87

84

80

76,5

72

66,5

60

51,5

481

334

815

250

148

27

57

MXV 40-807-60

5,5

7,5

132 SA

118

105

101

98

94

89

84

77,5

70

60

531

374

905

300

167

30

73

MXV 40-808-60

5,5

7,5

132 SA

134

120

116

112

107

102

96

89

80

69

561

374

935

300

167

31

74

MXV 40-810-60

7,5

10

132 SB

168

150

145

140

134

127

120

111

100

86

621

374

995

300

167

33

86

MXV 40-811-60

7,5

10

132 SB

185

165

159

154

147

140

132

122

110

94,5

651

374

1025

300

167

34

87

H
m

Head and power values valid for liquids with density


3
2
= 1.0 kg/dm and kinematic viscosity = max 20 mm/sec.
Pst = Power with reference to one stage.

Test results with clean cold water, without gas content.


A safety margin of + 0.5 m is recommended for the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

94

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 3450 rpm


7
*

 

  

*
**

7**

(*

(6*

( *

(**

8*

*



**

!


%

 @ +8
(

**

6**

@ +8


11

@ (+8
 

@ +8


**




**

**

6)4) (*+

>
(*4 5 "
 5 6*
(4
*

6*

6
;





1

7

:
*

* 2 ) ) ))

(**

*

*



6*

4*

* B)1) ) ))

Dimensions and weights

:
*

MXV 50-16

(**
*

8*

*
*

 +
 +

(*

(**

hC

**

**

6**

  +

(*

7 )47+(

6

@ +8 

*
%
(*

"1

6

*

@ +8 ( 

(


6*
8

(6
*

  

"

"

*

**

*
44
( 
(

6)4) (*+

A(6

(
6

*
*

(
( ;   $
  0 $ !, 
 :
6 1  %  <-)
%     ! 4*=  (8*=

Performance
"! # 
 *5(* 5*
 *5(*5*
 *5(*65*
 *5(*5*
 *5(*5*
 *5(*75*
 *5(*85*
 *5(*45*




6
/
7/
((
((
((
(
(




"
/
7/
(*
(
(
(
*
*

+

+

(( 
( 10
( 19
(* 0
(* 0
(* 0
(* 9
(* 9

*
64
7
48
(
(67
(7(
(4
*

:


(6

(*

**

/ / ** / / 6(/

 6



6
7*
4
((7
(6*
(6
(87
(*

6
8
4*
((
(
(8
(8(
*

6(

88
((*
(
(6
(7
(48

4
6(
6*
(
64
8
(8


6
76
76
678
678
678
678
678

7 4
784
8 6
44
(* 7
(*(
(*4
((*

(

(8

6* 8/ 

(
7
8
8(
7
(* (*( 4
( 8 ( ( ((6
(64 (6
(
(7* (
(
(4
(8
(7(


(

7*
88
(*
(
(6*
(8

66
8
7
87
(*(
((
((

; 1 6 (
*
**
**
*
*
*
*
*

(68
(7
(7
(47
(47
(47
(47
(47



7
4(
6 
6*
64
 4

"! 
! 
 
   
6
7
6
84
67 (**
7 ( 4
8 (*
4 ((
( (6

(67

  
 
   
   $! $ % &!  #
. !  , , / !  ,)
r ' ()* +  , $,#n ' - *  +,) 0 %#  % *)   , % 
"1 $!)     
.,  ,,,  213 44*/ 0- 0)
" ' "  %,   )

95

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 3450 rpm


2 ) ) ))

*

**

(*
(**

1

# 



(8*

**
6
<

(*

**

(6*

#


%

( *

A +8
 (

6**


(**

(*

(**

**

A +8


A (+8
 

A +8


;


C)1) ) )) *

*

(*

8*



**



 *

6)4) (*+

?
(*4 5 
 5 6*
(4

6*
(**
*
*
8*

*
*

 +
 +


(*

**

**

hD

6**

*
**

**

6*

*
8**

7**


((8
(6
(8

*
6





*

6

A +8 ( 

6*
8

**

A +8 

*
%
(*

1

6
*

(6
*

  

*

  +


(*

6*

*

7 )48+(

*

**

Dimensions and weights

;


MXV 65-32

6)4) (*+

B(6

(
6

*
*

(
( <   $"
  0 $" , "
 ;
6 1  % " =-)
% "  "   4*>  (8*>

*

Performance
 ! "
 5
 5
 5
 5
 5
 5

* 5*
*5*
*65*
*5*
*5*
*75*


#"

7/
((
(
(8/


"


(* ( 19
( (* 0
* (* 9
 (* :
* (8* 
* (8* 

+

+

*
*
/
8*
(*7
(6
(*
(87

(8

*

6

8

;"


67

** / 6/ ** / / 7** 78/

 6



64/ 68
76
7
44
4
( 6 ( *
(68 (66
(7 (8

6 7
*
64
4
6(
87

76
678
678
678
*
*

8*(
48(
(* 7
(*7
( 6
( 84

67 6/ 6/ 6( 7/ 


7*
8

(
7
*
46
4(
87
8
7
7
((7 ((6 (*4 (* 4
86
(6( ( (( (  (( (*
(6 (4 (
(66 (6 ((4

< 1 6 (
**
*
*
*
*
*

(7
(47
(47
(47
4
4

6
8*
6 
67
(8
6

 #"
# #
 
   
64 (*
8 (*
4 (66
( (

(77
6 (74

  
 
   
"  #" $" $ % & # "!
." " # ," , #"/ #  ,")
r ' ()* +  ", $,!n ' - *  +",) 0 %"!  % *)   ","" % "
1 $")     
.","  ,,," # 213 44*/ 0"- 0)
 ' #" # "%"","  " ")

96

MXV 80-48

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 3450 rpm


C*2* *!**

+
)+

)++

)+

++

+ 3!* *!** )++

Dimensions and weights


+

++

++

)+



 

6+

 

2

+


<

&



) +

"




A ,6
)

 +




)+




+

 , )+
 ,
++

++

+

hD

+

+
6++

+
)+++

#

+

+

  



A ,6 ) 


++

+
+

A ,6 

+
&
+

#2


+

)
+

8

#



+

+
++

6+
)
)+
++

+
8+

+

*5* )+,

)5

6+

+
+

 +

?
)+5 7 #
 7 +

;
6+

A ,6


11
)+

A ,6


A ),6
 

;
6+

6+

  , )+

+

+

+

+

8 *)+)

8+

B)

)


+
+

)

)+


*5* )+,

) <   %


  1 % "- 
 ;
 2 ! &  =.*
&  !   " 5+>  )6+>

Performance
#"! $!
 6+76+)7+
 6+76+ 7+
 6+76+7+
 6+76+7+
 6+76+7+



 , +
! 

 #
, +
0 80 ) 21
+
))
5
) )+ 1
)
660
+ )+ 9
)60
))6
 )+ :
)8
+ )6+  




5



6

+

+

+

8+

6++ 5++ )+++ )+6



+

;







0
+
)6
)
)0 50 8 0 
+ 0 )
880 8 8+0 8 0 + 0 0
)+ 55
5
65
6 850 8)

) 5 )  ))8 ))) )+8 550 65 880

 



)
5
8
)6
6+

8
86
86
86
+

6+
58
)+
)+5
) 6

< 2  )
++
+
+
+
+

)8
)58
)58
)58
5

6
8

5
8

#"!
"

 
5
5
)






 
58
))
)
)8
)5

  
 
   
  !  %" % & '"  $
/ "  - - 0 "  -*
r ( )*+ ,  - %-$n ( . +  ,-* 1 &$  & +*   - & 
#2 %"*     
/-  ---  324 55+0 1. 1*
# ( #   &-   *

97

MXV4 25-2

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 1750 rpm


0

U.S. g.p.m.

0 Imp. g.p.m.

3
2

Dimensions and weights


8

9
7

11

10
8

SM

MXV4 25-220-60

80

250

FM

MXV4
without
motor

18

60

16

200

14

ft

12

150

MXV4
with motor

(3)

h3
(1)

(1)
h2
G1

40

G1

DN 25

DN 25

10
75

75

8
7
6
5
4

20

20

100

3.93.011

(2)

215

3.93.011/1

MXV4 (G)
threaded
ports

(2)

250

MXV4 (F)
flanged
ports

50

180 210

0
0

m3/h
l/min

0.5

1
10

1.5

2.5

20

30

100

40

150

0.06

50

(1) Filling
(2) Draining
(3) Standard position of terminal box.
(for other positions rotate motor through 90 or 180)

12,5

Pst

0.04

30
20

Pst

10

kW

Counterflanges

0.02

in stainless steel

14

NPSH
m
1

EN 1092-2
PN 25-40

43

0.01

0
1,5

Flanges

ft

DN 25

115
85
65
25

G1

0.5
0

m3/h

0.5

1.5

72.1025.60

(4) With standard motor


(5) Weight MXV4 (G) = weight MXV4 (F) - 1kg
(6) Net weight pump with standard motor

2.5

Performance
Pump type

Motor
power
kW

Motor
size

HP

Dimensions
mm

m3/h

0,6

0,9

1,2

1,5

1,8

2,1

2,4

l/min

10

15

20

25

30

35

40

h2

M (4)

h3

FM

16

15

14

13

11,5

10

372

234

606

200

Pump weight
without with
motor motor
SM (4) kg (5) kg (6)

0,55 0,75
0,55 0,75

80 A4

120

18

26

80 A4

20,5 18,5 17,5

16

14,5 12,5

11

8,5

396

234

630

200

120

19

27

0,55 0,75
0,55 0,75

80 A4

24,5

22

19

17,5

13

10

420

234

654

200

120

20

28

80 A4

28,5

26

12

444

234

678

200

120

21

29

0,55 0,75
0,55 0,75

80 A4

468

234

702

200

120

22

30

516

234

750

200

120

23

31

564

234

798

200

120

25

33

MXV4 25-214-60

0,55 0,75
0,75
1

MXV4 25-216-60

0,75

MXV4 25-218-60
MXV4 25-220-60

MXV4 25-204-60
MXV4 25-205-60
MXV4 25-206-60
MXV4 25-207-60
MXV4 25-208-60
MXV4 25-210-60
MXV4 25-212-60

21

15

24,5 22,5 20,5 17,5 15,5

32,5 29,5

28

25,5

23

20

40,5

37

35

32

29

25

80 A4

49

44,5

42

38,5

35

30

80 B4

57

52

49

45

40,5

35

31

24

612

234

846

200

120

26

35

80 B4

65

59

56

51

46,5

40

35

27

660

234

894

200

120

28

37

0,75

80 B4

73

66,5

63

57,5

52

45

708

234

942

200

120

30

39

1,1

1,5

90 S4

81

74

70

64

58

50

766

282

1048

200

128

32

44

80 A4

H
m

Head and power values valid for liquids with density


= 1.0 kg/dm3 and kinematic viscosity = max 20 mm2/sec.
Pst = Power with reference to one stage.

17,5 13,5
22

17

26,5 20,5

39,5 30,5
44

34

Test results with clean cold water, without gas content.


A safety margin of + 0.5 m is recommended for the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

98

MXV4 32-4

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 1750 rpm


0

U.S. g.p.m.

Imp. g.p.m.

10
5

Dimensions and weights

15

20

10

SM

15

80
250
M

MXV4 32-418-60
H

FM

ft

60

MXV4
without
motor

200

16

MXV4
with motor

(3)

h3

14

(1)

(1)

11

h2

150

12

G 1 1/4

40

G 1 1/4

DN 32

DN 32

10
75

75

8
7
6
5
4

20

100
20

3.93.011

(2)

215

3.93.011/1

MXV4 (G)
threaded
ports

(2)

250

MXV4 (F)
flanged
ports

50
180 210

0
0

m3/h
l/min

2
20

3
40

100

80

60

60

150

0.06

Pst

40

(1) Filling
(2) Draining
(3) Standard position of terminal box.
(for other positions rotate motor through 90 or 180)

12,5

0.04

Pst

30

kW

Counterflanges

20

0.02

in stainless steel

10
1.5

0.01

Flanges

EN 1092-2
PN 25-40

43
19

NPSH
m
1

ft

DN 32

140
100
76
32

G 1 1/4

0.5
0

m3/h

72.1026.60

(4) With standard motor


(5) Weight MXV4 (G) = weight MXV4 (F) - 1kg
(6) Net weight pump with standard motor

Performance
Pump type

Motor
power

Motor
size

m3/h

0,9

1,2

1,8

2,4

20

30

Dimensions
mm

3,6

4,2

40

50

60

70

h2

M (4)

h3

FM

12

10

372

234

606

200

Pump weight
without with
motor motor
SM (4) kg (5) kg (6)

15

0,55 0,75
0,55 0,75

80 A4

16

15

120

19

27

80 A4

20

18,5

18

16,5

15

12,5

10

6,5

396

234

630

200

120

20

28

0,55 0,75
0,55 0,75

80 A4

24

22

21,5

20

18

15

11,5

420

234

654

200

120

21

29

80 A4

28

26

25

23

20,5 17,5 13,5

444

234

678

200

120

22

30

80 A4

32

29,5

29

26,5 23,5

20

15,5 10,5

468

234

702

200

120

23

31

MXV4 32-410-60

0,55 0,75
0,55 0,75

40

37

36

33,5 29,5

25

19,5

13

516

234

750

200

120

25

33

MXV4 32-412-60

0,75

80 B4

48

44,5

43

35,5

30

23,5

16

564

234

798

200

120

26

35

MXV4 32-414-60

0,75

80 B4

56

52

50,5 46,5 41,5

35

27,5 18,5

612

234

846

200

120

28

37

MXV4 32-416-60

1,1

1,5

90 S4

64

59

57,5

53

47,5

40

31

21

670

282

952

200

128

31

46

MXV4 32-418-60

1,1

1,5

90 S4

72

66,5

65

60

53

45

35

24

718

282

1000

200

128

33

48

kW
MXV4 32-404-60
MXV4 32-405-60
MXV4 32-406-60
MXV4 32-407-60
MXV4 32-408-60

HP

l/min

80 A4

H
m

Head and power values valid for liquids with density


= 1.0 kg/dm3 and kinematic viscosity = max 20 mm2/sec.
Pst = Power with reference to one stage.

14,5 13,5

40

Test results with clean cold water, without gas content.


A safety margin of + 0.5 m is recommended for the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

99

MXV4 40-8

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 1750 rpm


0

U.S. g.p.m.

Imp. g.p.m.

10

15

20

10

Dimensions and weights

25

15

35

30

20

SM

30

25

MXV4 40-819-60

80

250

FM

ft

17
60

(3)

MXV4
without
motor

MXV4
with motor

200

15

h3
(1)

(1)

13

h2

150

11
10

G 1 1/2

20

G 1 1/2

DN 40

DN 40

80

80

8
7
6
5
4

100

3.93.011

20

40

(2)

225

3.93.011/1

MXV4 (G)
threaded
ports

(2)

280

MXV4 (F)
flanged
ports

50
215 246

0
0

m3/h
l/min

40

60

5
80

7
120

6
100

60

0.12
Pst
kW
0.08

Pst

40

0.06
0.04

20

Counterflanges

Flanges

in stainless steel

EN 1092-2
PN 25-40

43
19

190

0.02

3
NPSH
m
2

(1) Filling
(2) Draining
(3) Standard position of terminal box.
(for other positions rotate motor through 90 or 180)

14
130

140

ft
8

150
110
84
40

G 1 1/2

DN 40

4
0

m3/h

72.993.60

(4) With standard motor


(5) Weight MXV4 (G) = weight MXV4 (F) - 1kg
(6) Net weight pump with standard motor

Motor
size

m3/h

2,3

3,6

4,2

4,8

5,4

6,9

8,1

l/min

38,3

50

60

70

80

90

100

115

135

h2

M (4)

h3

FM

13,5 12,5 11,5

10

Performance
Pump type

Motor
power
kW

HP

Dimensions
mm

Pump weight
without with
motor motor
SM (4) kg (5) kg (6)

0,55 0,75
0,55 0,75

80 A4

17

16

15,5

15

14

6,5

401

234

635

200

120

21

29

MXV4 40-805-60

80 A4

21,5

20

19

18,5

18

17

16

14,5 12,5

431

234

665

200

120

22

30

MXV4 40-806-60

0,75

80 B4

26

24

23

22

21,5

20

19

17,5

10

461

234

695

200

120

23

32

MXV4 40-807-60

0,75

80 B4

30

28

27

26

25

23,5

22

20,5 17,5 11,5

491

234

725

200

120

25

34

MXV4 40-808-60

1,1

1,5

90 S4

34,5

32

31

27

25

MXV4 40-810-60

1,1

1,5

90 S4

43

40

38,5

37

MXV4 40-811-60

1,1

1,5

90 S4

47

44

42,5

41

39

37

34,5

MXV4 40-813-60

1,5

90 L4

56

52

50

48

46

43,5

41

MXV4 40-815-60

1,5

90 L4

64,5

60

58

55,5

53

50

47

MXV4 40-817-60

2,2

100 L4

73

68

65,5

63

60,5

57

53,5

49

42,5

MXV4 40-819-60

2,2

100 L4

82

76

73

60

55

47,5 31,5

MXV4 40-804-60

H
m

Head and power values valid for liquids with density


= 1.0 kg/dm3 and kinematic viscosity = max 20 mm2/sec.
Pst = Power with reference to one stage.

29,5 28,5

35,5 33,5 31,5

70,5 67,5 63,5

15

23

20

13

531

282

813

200

128

27

39

29

25

16,5

591

282

873

200

128

29

41

32

27,5

18

621

282

903

200

128

30

42

37,5 32,5 21,5

681

282

963

200

128

31

46

43,5 37,5 24,5

741

282

1023

200

128

33

48

811

313

1124

250

135

36

60

871

313

1184

250

135

39

63

28

Test results with clean cold water, without gas content.


A safety margin of + 0.5 m is recommended for the NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

100

MXV4 50-16

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 1750 rpm

)++

B*2* *!**

3!* *!**

+
+

+

+

+

8+



2

+

 

 

 +








@ ,6





6+

+
+

 ,
 ,


)++

+

)+
)+

)
++

++

*5* )+,

> )+5 7 #  7
+
)5

+
55
) 
)

)
+

+*

#

#
+*)


+
+

@ ,6 

  ,

)+

8 *55
*+

)


+7)+7+

+7)+
7+

+7)+7+

+7)+7+

+7)+87+

+7)+67+

+7)+57+

+7))+7+

+7)))7+

+7)) 7+

+7))
7+

+7))7+


! 

0
0
0
0
0
0
0







#








0
0

 ,

,

)++ 9

)++ 9

)++ 9

)++ 9

)++ 9

)++ 9

)++ 9

)++ 9

)++ 9

)++ 9

)) 

)) 

*5* )+,

A)

+
+

)
) ;   %
  1 % "- 
 :

 2 ! &  <.*
&  !   " 5+=  )6+=

Performance
#"! $!




)

+

@ ,6 ) 

)
&


#2


  

@ ,6


: +

)+

11

@ ),6
 

++

8+
+
hC



@ ,6
)

5+

+

"






+
&











;

: +

6+

+

Dimensions and weights

08

80

608

)+0

8+

5

) +

)


)8+ )5

+

)6
)8
) )0 )

)
))

0 )0 +0 )5
)8
)
+
6
8
0

)0 )5


 0 +0 60

0

)0 50 6 0 


+


80


)
6 
0 +
0 )
60



5


50 0 

)
80
 80
0 
50 


80
)
8)0 6

)
8 )0

60 85 80 8)0 0 +  0
5 5+0 60 6)0 8
5
+

6
)+0
)
)0
)6
)
0

60
)
0

)0

:


))08 )06


 




5

+

55

6
+
8
8)
8+
88
6

)
)
)
)
)
)
)
)
)
)




8+6
8

888
6)
6

66)
5)
5+
56

)+)5
))+5
))86

; 2 
 )
+
+
+
+
+
+
+
+
+
+
+
+

)
)
)
)
)
)
)
)
)
)
)
6
)
6


8
5)

+

5
 5


56

8+
88)

#"!
"

 

5
)




6
)




 

8
5
8+
8
8
8
86
6+
6)
65
5

   


  !  %" % & '"  $
/ "  - - 0 "  -*  
  
r ( )*+ ,  - %-$n ( . +  ,-* 1 &$  & +*   - &  #2 %"* 
   
/-  ---  324 55+0 1. 1*
# ( #   &-   *

101

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 1750 rpm


;22 '2(22

<(2 '2(22





Dimensions and weights















#$"%$
"$"&

/$








7 
 

   







!$
D

/$






 






 
 



 
 

 
 




 
 
 
 
  


22

  "&:"$*
7  


 


 

 

 

 

 

 

 

 
 
 



"$"&
("# &
 






 
 
 
 

"$"&
!:  

 
 
 
 
 
  




















 





 









 

 

 
 
 

 








 

 
 








 

8
2 2
 
7   




 )' *+ *& , $

 -& , $ !%.$" !+
  &*'
 $*+*&+ ("!$" "/ $ &* 0"12
/"& "$ & ("!$"! &"$*$ "$"& $&"%'  3 "&  3

Performance

%( $=(

2 2
 





2
!$
2

2


5


 45  

5
  



  
  



D9




7 



 

7 
 

7 



#$ "$"&

5 

60 Hz

5 

MXV4 65-32























 














 !"!

  )



 

 


 

  

 

  

  

 
 


 
 
 
 
 
 
 



















%( # '$
#$"%$ #$
"$"& "$"&
'  ' 
 
 






 
  
 

 $ !$*+*&+ "$"&


 *+ *+ ("# & ,*% ! ,*+ /"& >%+! #$ + !$=

@ !$ & !%$! #$ . * ."+ #*$ & #$"%$ '*! ."$ $2   5 C A
'
r ? 2 '+ *+  *$. ,!."!$=n ? *1
 ! .2 - !*/ $= *&' "/ A 2  ! & ." + + /"& $ 5 ,*% 2
 "&:"$* C A '
@" &*. !  *.."&+*. #$ <B   - 1 -2
!$ ? "# & #$ & / & . $" " !$*' 2
102

MXV4 80-48

60 Hz

Vertical Multi-Stage In-Line Pumps

Characteristic curves n 1750 rpm


+

)++

)+

+

2

 

 

<

&



"


+

+

+



)+



++

+



)++

A ,6


)++

A ,6
)
A ),6
 

A ,6




)+







*5* )+,

?
)+5 7 #
 7 +
+

)5

+

 +

)+

+
+

)+

 ,
 ,


+
++

+
++

++

8+
hD
+

++

+
++

A ,6 

)+

)+

+

8 *)+

+

*5* )+,

B)

)


&



A ,6 ) 

#2
 

  ,

+

  

+*8
#
+*

+* 

#

+

)
+

)*++

+

6+
)
)+
++

++

11

;
6+

3!* *!**

+

C*2* *!**

;
6+

8+

Dimensions and weights

+
+

)
) <   %
  1 % "- 
 ;
 2 ! &  =.*
&  !   " 5+>  )6+>

Performance
#"! $!
  6+76+ 7+
  6+76+7+
  6+76+7+
  6+76+7+
  6+76+7+
  6+76+87+
  6+76+67+


! 
 #
0

0






0

0
0 80



)++ :1
)++ :1
)++ :9
)++ :9
)) 
)) 
) 2

,

)

)6

,

++

+

++

+

)0

)
)50
5

0 

5
)

60 )0

;


+



++ +

++

++

 

) 0 )
)) )+0 50 60
)60 )80 )8 )0 )0 )

0
0
)
)5
)8
)
50
6


)0
8 0 0 )
5

0 )0 5 0 0 +
50 8
 )0 60 0


5
)
)
)6
)



+8
6
+
5)
8
6

)
)
)
)


8



< 2  )

85
+
6 +
+
66)
+
5
+
)+  +
)+6 +
) +6 ++

)
)
)
)
)6
)6
)8

8

5
8
)6
85
8)

#"!
"

 
6
+


6
)
8




 
8
8
85
6)
65
5
))

   


  !  %" % & '"  $
/ "  - - 0 "  -*    
 
r ( )*+ ,  - %-$n ( . +  ,-* 1 &$  & +*   - & 
#2 %"*      
/-  ---  324 55+0 1. 1*
# ( #   &-   *

103

MXV

60 Hz

Vertical Multi-Stage In-Line Pumps

Features
Long Service Life with Standard Motor
Pump with thrust bearing without additional axial loads on the
motor bearings.
Any standard motor V1 design (suitable to be lifted in vertical
position) can be used, of our choice or of Clients choice.

Easy Assembly of the Motor


With the single-piece sleeve coupling the pump unit can be supplied
fully assembled also without the motor. This eliminates the risk of
damage caused by shifting of the pump shaft during transportation.
The motor is simply inserted in the coupling and fastened to the
flange without the necessity for adapting the axial position of the
pump shaft.

34.02
20.00
14.04
36.00
14.02
64.00
64.15
28.00
25.02
25.03
64.10

Extra Safety
Single-piece coupling guard to be removed only by means of a tool,
positioned around the lantern bracket, thus avoiding accidental
pushing and rubbing against the coupling.

13.60
14.54
16.00
34.01
14.12
3.93.029

MXV 25-2, 32-4, 40-8


Low Cost Installation
Vertical construction with reduced pump height for installation in
small spaces.
In-line connections to simplify the piping layout with the possibility
of inserting the pump in straight pipe-lines.
Disassembly, inspection or cleaning of internal parts without
removal of piping.

Robust and Reliable


Single PN 25 construction for all pump sizes.
The suction and discharge nozzles arranged in-line absorb the forces
of the piping on the pump without the creation of distorting loads
causing local friction and early wears.
The lantern brackets compact and robust design maintains a sure
alignment between rotating and fixed parts, reducing vibration.
The upper cover design prevents entrapment of air around the
mechanical seal.

14.04
34.02
36.00
14.02
28.00
25.02
64.00
14.54
64.15
14.42
25.03

Low-Noise Operation

64.10

The water filled shroud around the stages and thick external walls,
work together for low-noise operation.
Low-noise standard motor.

14.00
14.12
14.12
3.93.112

MXV 50-16, 65-32, 80-48


104

MXVL 60 Hz AISI 316

Vertical Multi-Stage In-Line Pumps


Construction
Vertical multi-stage pumps with suction and delivery connections of
the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped
liquid.
A pump with thrust bearing and sleeve coupling for use of any
standard motor with V1 construction.

Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting
systems, fire-extinguishing systems, high-pressure washing
plants, irrigation, agricultural uses and sport installations.

Operating conditions
Temperature of liquid: from -15 C to +110 C.
Operating environment temperature: up to 40 C.
Maximum permissible pressure in pump casing: 25 bar.

Motor
Standard-type: 2-4 pole induction motor, 60 Hz.
Classification scheme EFF2 or EFF1 (High efficiency) on request.
Construction IM V1 (IEC 34-7).
Insulation class F (IEC 85).
Protection IP 55 (IEC 529).
three-phase with rated voltage: up to 3 kW 220/380 V (IEC 38);
from 4 kW 380/660 V (IEC 38).
Rated speed of rotation (60 Hz):

MXVL 25-2, 32-4, 40-8

MXVL = 3450 rpm


MXVL4 = 1750 rpm.

MXVL 50-16, 65-32, 80-48

All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel-molybdenum stainless steel AISI 316L.

Internal parts in contact with the liquid with pump casing and upper
cover in chrome-nickel-molybdenum stainless steel AISI 316L.

Materials (wetted parts)

Materials (wetted parts)

Pos. Nr.
(pag.108)

Pos. Nr.
(pag.108)

13.60
14.02
16.00
20.00
25.02
28.00
34.01
34.02
64.15
64.00
64.10
25.03
36.00
14.54

Component
Flange
External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing
Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Material

Component

14.00 Pump casing


34.02 Upper cover
Chrome-nickel-molybdenum steel
1.4404 EN 10088 (AISI 316L)

14.02
25.02
28.00
64.15
64.00

Chrome-nickel-molybdenum steel
1.4404 EN 10088 (AISI 316L)
Corrosion-resistant, cemented carbide
Ceramic alumina

64.10
25.03
36.00

Hard metal/Carbon/EPDM.

14.54

PTFE
NBR

External jacket
Stage casing
Impeller
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing
Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Material
Chrome-nickel-molybdenum steel
1.4404 EN 10088 (AISI 316L)
Chrome-nickel-molybdenum steel
1.4404 EN 10088 (AISI 316L)
Chrome-nickel-molybdenum steel
1.4404 EN 10088 (AISI 316L)
Corrosion-resistant, cemented carbide
Ceramic alumina
Hard metal/Carbon/EPDM

PTFE
NBR

Direction of rotation: clockwise as seen from the motor.

Direction of rotation: anticlockwise as seen from the motor.

Variants (to be specified when ordering)

Variants (to be specified when ordering)

Pump with threaded ports (G).


Pump with flanged ports (F).
Pump without motor.
Pump with standard motor.

Pump without motor.


Pump with standard motor.

Other variants (on request)

Other variants (on request)

O-rings FPM.
Other mechanical seal.
Pump with motor of Client's choice (if available).
Other voltage ratings.
Pump with support feet for horizontal installation (H1 or H2).
Support feet for horizontal installation, set.
Welding counter-flanges, PN 25 (steel).

With counter-flanges in chrome-nickel steel.


O-rings FPM.
Other mechanical seal.
Pump with motor of Client's choice (if available).
Single-phase motor 220 V, up to 2.2 kW.
Other voltage ratings.

Higher or lower liquid or ambient temperatures.

Higher or lower liquid or ambient temperatures.


105

11.1

MXVL 60 Hz AISI 316

Vertical Multi-Stage In-Line Pumps

MXVL 25-2, 32-4, 40-8

MXVL 50-16, 65-32, 80-48

Designation

Designation
MXV L 25-205 - 60

G *

MXV L 50-1605-60

Series
AISI 316 vesion
DN ports in mm
Rated capacity in m3/h (n = 3450 rpm)
Number of stages
Frequency 60 Hz

Series
AISI 316 vesion
DN ports in mm
Rated capacity in m3/h (n = 3450 rpm)
Number of stages
Frequency 60 Hz

Construction variants
special seal code (no code = standard seal)
threaded ports
flanged ports
with motor (or without motor)
* with no further designation = with standard motor

Construction variants
special seal code (no code = standard seal)
materials combination: A (standard)
with support feet for horizontal installation H, variant 1
with motor (or without motor)
* with no further designation = with standard motor

G
F

A H1 *

Installations

Pipe connection

Vertical installation
(Standard).

4.93.213/1

4.93.213/2

4.93.213/3

4.93.213/4

3.93.013

Pump with threaded ports:


pipes screwed into the ports

Pump with threaded ports:


pipes with union couplings
(locally available)

Horizontal installation.

Pump with flanged ports:


pipes with counter-flanges

Pump size

Number
of stages

Stage casings
with bearing

40 - 803
40 - 804
40 - 805
40 - 806
40 - 807
40 - 808
40 - 810

3
4
5
6
7
8
10

1
1
1
1
1
1
1

40 - 811

11
12
13
14
15
16
18

2
2
2
2
2
2
2

17
19
20

3
3
3

MXVL
MXVL4
MXV --MXV4
32 - 403
32 - 404
32 - 405
32 - 406
32 - 407
32 - 408
32 - 410

25 - 212

32 - 412

25 - 214

32 - 414

25 - 216
25 - 218

32 - 416
32 - 418

40 - 813
40 - 815

40 - 817
40 - 819
25 - 220

Variant H2:
suction on the right,
delivery on the left.

Variable parts

Variable parts

25 - 203
25 - 204
25 - 205
25 - 206
25 - 207
25 - 208
25 - 210

Variant H1:
suction on the left,
delivery on the right.

Pump size

Number
of stages

Stage casings
with bearing

80 - 4801
80 - 4802
80 - 4803
80 - 4804
80 - 4805

1
2
3
4
5
6
7
8
9
10

1
1
1
1
1
1
1
1
1
1

80 - 4806
80 - 4807
80 - 4808

6
7
8
9
10
11
12
14
16

2
2
2
2
2
2
2
2
2

MXVL
MXVL4
MXV --MXV4

50 - 1603
50 - 1604
50 - 1605
50 - 1606
50 - 1607
50 - 1608
50 - 1609
50 - 1610

65 - 3202
65 - 3203
65 - 3204
65 - 3205
65 - 3206
65 - 3207

65 - 3208
65 - 3209
65 - 3210
50 - 1611
50 - 1612
50 - 1614
50 - 1616

106

65 - 3212

MXVL 60 Hz AISI 316

Vertical Multi-Stage In-Line Pumps

Coverage chart
5

U.S. g.p.m.

10

20

Imp. g.p.m.

30

10

20

40

50

30

200

100

40

50

300
200

100

400
300

300

900

MXVL

n 3450 rpm

200

ft
500

H
m

400

MXVL 25

MXVL 32

MXVL 40

MXVL 65

MXVL 50

100
300

200

MXVL 80
50
40
100

30

20

15

m3/h

Q l/min 30
20

2
40

3
50

10
100

30
500

20

150

200

300

400

40

50
60 70 80 90 100
1000
1500

50

72.1002

3
2

U.S. g.p.m.
5

10

Imp. g.p.m.

30

20
20

10

40

50

30

40

100
50

150
100

100

300

MXVL4

n 1750 rpm

200

50

40

ft
100

30

MXVL4 25

MXVL4 32

MXVL4 40

MXVL4 50

MXVL4 65

20

MXVL4
80

50
40

10
30

20
5
0.5

/h
Qm
l/min
3

10

2
20

30

40

3
50

10
100

150

20
200

300

400

30
500

40
600
72.1002/1

For characteristic curves, dimensions and weights see cap. 11


107

11.1

MXVL 60 Hz AISI 316

Vertical Multi-Stage In-Line Pumps

Features
Long Service Life with Standard Motor
Pump with thrust bearing without additional axial loads on the
motor bearings.
Any standard motor V1 design (suitable to be lifted in vertical position) can be used, of our choice or of Clients choice.

Easy Assembly of the Motor


With the single-piece sleeve coupling the pump unit can be supplied
fully assembled also without the motor. This eliminates the risk of
damage caused by shifting of the pump shaft during transportation.
The motor is simply inserted in the coupling and fastened to the
flange without the necessity for adapting the axial position of the
pump shaft.

34.02
20.00
14.04
36.00
14.02
64.00
64.15
28.00
25.02
25.03
64.10

Extra Safety
Single-piece coupling guard to be removed only by means of a tool,
positioned around the lantern bracket, thus avoiding accidental
pushing and rubbing against the coupling.

13.60
14.54
16.00
34.01
14.12
3.93.029

MXVL
25-2,32-4,
32-4, 40-8
40-8
MXV
25-2,
Low Cost Installation
Vertical construction with reduced pump height for installation in
small spaces.
In-line connections to simplify the piping layout with the possibility
of inserting the pump in straight pipe-lines.
Disassembly, inspection or cleaning of internal parts without
removal of piping.

Robust and Reliable


Single PN 25 construction for all pump sizes.
The suction and discharge nozzles arranged in-line absorb the forces
of the piping on the pump without the creation of distorting loads
causing local friction and early wears.
The lantern brackets compact and robust design maintains a sure
alignment between rotating and fixed parts, reducing vibration.
The upper cover design prevents entrapment of air around the
mechanical seal.

14.04
34.02
36.00
14.02
28.00
25.02
64.00
14.54
64.15
14.42
25.03

Low-Noise Operation

64.10

The water filled shroud around the stages and thick external walls,
work together for low-noise operation.
Low-noise standard motor.

14.00

108

14.12
14.12
3.93.112

MXVL50-16,
50-16, 65-32,
MXV
65-32,80-48
80-48

MXV-E

Variable Speed Multi-Stage Vertical Pumps


(max 2900 rpm)
Construction
Vertical multi-stage pumps with suction and delivery connections of
the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped
liquid.

MXV-E (AISI 304) Internal parts in contact with the liquid in


chrome-nickel stainless steel 304, with pump casing and upper
cover in cast iron for MXV-E 50-65-80.
MXVL-E (AISI 316L) Internal parts in contact with the liquid
in Cr-Ni-Mo AISI 316L, including pump casing and upper cover
for MXVL-E 50-65-80.

12
Applications
Building services pressure boosting.
Water supply to multi-storey buildings.
Washing plants.
Industrial pressure boosting systems.
Performance curve adjustment for industrial system application.

Operating conditions
For clean non-explosive liquids, without solid, filamentary or abrasive matter (with adaptation of sealing materials on request).
Temperature of liquid: from -15 C to +110 C.
Operating environment temperature: up to 0 40 C.
Maximum permissible pressure in pump casing: 25 bar.

Materials (wetted parts)

For all types

50,65,80

25,32,40

Inverter-Motor
Component

MXV-E ( AISI 304)

MXVL-E (AISI 316L)

Flange
External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve

Cr-Ni steel
1.4301 EN 10088
(AISI 304)

Cr-Ni-Mo steel
1.4404 EN 10088
(AISI 316L)

Special features on request


Cast iron
GJL 250 EN 1561

Cr-Ni-Mo steel
1.4404 EN 10088
(AISI 316L)

External jacket
Stage casing
Impeller
Spacer sleeve

Cr-Ni steel
1.4301 EN 10088
(AISI 304)

Cr-Ni-Mo steel
1.4404 EN 10088
(AISI 316L)

Pump shaft
Plug

Cr-Ni steel
1.4305 EN 10088
(AISI 303)

Cr-Ni-Mo steel
1.4404 EN 10088
(AISI 316L)

Pump casing
Upper cover

Bearing sleeve/
Bearing in stage casing
Mechanical seal
ISO 3069 - KU

Rated speed of rotation (50/60 Hz): max n = 2900 rpm


Inverter supply: three-phase 380-480 V 5%, 50/60 Hz.
2-pole induction motor.
Construction IM B5.
Insulation class F.
Protection IP 55.

Corrosion-resistant, cemented carbide/


Ceramic alumina

PTFE

O-rings

NBR

Designation
MXV L - E 25 -2 05 G
MXV L - E 50-16 05 H1
Series
AISI 316L Version (no code = AISI 304 version)
Variable Speed
DN ports in mm
Rated capacity in m3/h (n = 2900 rpm)
Number of stages

Hard metal/Carbon/EPDM

Wear ring

- Special mechanical seal.


- O-rings FPM.
- Higher or lower liquid or ambient temperatures.
- Flanges to screw, in chrome-nickel steel for MXV-E 25-32-40.

Construction variants
threaded ports
flanged ports
with support feet for horizontal installation H, variant 1

109

G
F

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Advantages
- Energy saving.
- Compact Design.
- Economical use of space.
- Flexible operation.
- Low-noise operation.
- Programmable to suit the system requirements.

Main features
Control range 1500 to 2900 rpm.
Dry-running protection.
Phase failure protection.
Overload protection.
Low-noise: max 64 dB(A).

Modality of use
200

200

Constant pressure mode


With a pressure transducer
the system maintains a constant pressure with variation
of flow.

150
H 100
m

Fixed speed mode


max

150

Variation of the operating


frequency allows for the
choice of operating curve to
match the system
requirements

H 100
m

50

50

min
0

4
6
Q m 3/h

4
6
Q m 3/h

The system is factory programmed and can be easily modified via the local control panel.

Coverage chart n 2900 rpm


4

Imp. g.p.m.

10

20

30

40

50

100

200

250
800

MXV-E
n 2900 1/min

700

200

ft

500

150

25-2

40-8

32-4

400
100
300

50-16
200
50

65-32
100

80-48
0

m3/h
l/min

2
30

3
40

50

6
100

9 10
150

16
200

20
300

32
400

500

40

48

60

70

1000
72.936/1

110

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Characteristic curves and performance n 2900 rpm


0

U.S. g.p.m.

10

15

20

240

MXV-E 25-220

220

n 2900 1/min

700

200

18
600

180

16

ft

H
m

14

500

12

140

12
400

120

10
100
300

8
80

7
6

60

200

5
4

40
100
20

0
0

m3/h
l/min

2
20

30

40

3
50

4
60

5
70

80
0.2

50

Pst
Pst

40

0.1

kW

30
4

10

NPSH
2

ft

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity =
max 20 mm2/sec.

Pst = Power with reference to one stage.

m
0
0

m3/h

72.983

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for the
NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

MXV-E 25 - 204
MXV-E 25 - 205
MXV-E 25 - 206
MXV-E 25 - 207
MXV-E 25 - 208
MXV-E 25 - 210
MXV-E 25 - 212
MXV-E 25 - 214
MXV-E 25 - 216
MXV-E 25 - 218
MXV-E 25 - 220

m3/h

P2

Pump type
kW

HP

0,75
1,1
1,1
1,5
1,5
2,2
2,2
3
3
3
4

1
1,5
1,5
2
2
3
3
4
4
4
5,5

l/min

H
m

1,5

16,6

25

33,3

44
56
68
79,5
91
114
136
159
182
205
228

42,5
53
63,5
74
85
106
127
149
170
191
213

40
50
60,5
70,5
80,5
101
121
141
161
181
202

37,5
47
56
65,5
75
94
112
131
150
169
188

111

3,5

41,6

50

58,3

66,6

75

34,5
43
51,5
60
69
86
103
121
138
155
173

31
39
46,5
54,5
62
78
93,5
109
124
140
156

27
34
40,5
47,5
54
68
81,5
95
108
122
136

22,5
28
34
39,5
45,5
57
68
79,5
91
102
114

17
21
25
30
34
42
51
59
68
76
85

2,5

4,5

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Characteristic curves and performance n 2900 rpm


0

U.S. g.p.m.

10

20

30

240

n 2900 1/min

220

700
200

MXV-E 32-418
600

180

ft

16

500

14

140

12

120

400

10

100

300

8
7
6
5
4

80

60

40

200

100
20

0
0

m /h
Q l/min

3
50

55

6
100

9
150

0.25

0.2

Pst

Pst
kW

45
%

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for the
NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

0.1
0.05

35
4

10

NPSH
2

ft

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity =
max 20 mm2/sec.

Pst = Power with reference to one stage.

m
0
0

m3/h

72.984

MXV-E 32 - 404
MXV-E 32 - 405
MXV-E 32 - 406
MXV-E 32 - 407
MXV-E 32 - 408
MXV-E 32 - 410
MXV-E 32 - 412
MXV-E 32 - 414
MXV-E 32 - 416
MXV-E 32 - 418

m3/h

P2

Pump type
kW

HP

1,1
1,5
1,5
2,2
2,2
3
3
4
4
5,5

1,5
2
2
3
3
4
4
5,5
5,5
7,5

l/min

H
m

2,5

3,5

41,6

50

58,3

45
56
68
79,5
91
114
136
159
182
205

41,5
51,5
62
72,5
83
104
124
145
166
187

40
50
60
70,5
80,5
101
121
141
161
181

38,5
48
58
68
78
97,5
117
136
156
175

112

83,3

100

116,6

133,3

32,5
41
49,5
58
66
83
99,5
116
132
149

27,5
34,5
42
49
56
70
84
98
112
126

22
27,5
33,5
39
44,5
56
67
78
89,5
100

14,5
18,5
22,5
26,5
30
38
45,5
53
60,5
68

4,5

66,6

75

36,5
46
55,5
65
74
93
111
130
148
167

34,5
43,5
52,5
61,5
70
88
105
123
140
158

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Characteristic curves and performance n 2900 rpm


U.S. g.p.m.

20

30

40

50

60

240

n 2900 1/min

220

200

700

MXV-E 40-817
600

180

ft

15

500

13

140

12
400

120

10
100
300

8
80

60

200

4
40
100
20

0
0

m3/h 2
l/min

6
100

50

10

14

12
200

150

70

0.4

Pst

Pst

60

0.2

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for the
NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

kW

50
4

NPSH

10

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity =
max 20 mm2/sec.

ft

2
m
0

Pst = Power with reference to one stage.

0
0

m3/h 2

10

72.392

12

14

MXV-E 40 - 804
MXV-E 40 - 805
MXV-E 40 - 807
MXV-E 40 - 808
MXV-E 40 - 810
MXV-E 40 - 813
MXV-E 40 - 815
MXV-E 40 - 817

m3/h

P2

Pump type
kW

HP

2,2
2,2
3
4
5,5
5,5
7,5
7,5

3
3
4
5,5
7,5
7,5
10
10

l/min

H
m

10

11

12

13

83,3

100

116,6

133,3

150

166,6

183,3

200

216,6

47
59
83
95
119
155
179
202

43
54
76
87
109
141
163
184

42
53
74
85
106
138
159
180

41
51
72
82
103
134
154
175

40
50
69
79
99
129
149
168

37
47
66
75
94
122
141
159

34
43
60
69
86
111
128
145

30
38
53
60
75
98
113
128

26
32
45
51
64
84
96
109

21
26
36
42
52
68
78
89

113

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Characteristic curves and performance n 2900 rpm


0 U.S. g.p.m. 20

40

60

80

100

n 2900 1/min

140

400

MXV-E 50-1607

120

ft

100

300

80

4
200

60

3
40
100
20

0
0

m3/h
l/min

10
100

150

15
200

20

250

300

25
350

400
1.0

80
Pst

Pst

60

0.6

kW

40
8

0.2

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for the
NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

20

NPSH

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity =
max 20 mm2/sec.

ft

10

Pst = Power with reference to one stage.


0
0

m /h

10

20

25

P2

Pump type
MXV-E 50 - 1603
MXV-E 50 - 1604
MXV-E 50 - 1605
MXV-E 50 - 1606
MXV-E 50 - 1607

15

72.937

m3/h

kW

HP

4
5,5
5,5
7,5
7,5

5,5
7,5
7,5
10
10

l/min

H
m

10

12

14

16

18

20

22

24

133,3

166,6

200

233

266

300

333

366

400

51
69
86
103
120

49
65
81
98
114

48
63
79
95
111

46
61
76
92
107

44
59
73
88
103

41
55
69
83
97

38
51
63
76
89

33
44
55
67
78

27
37
46
55
64

20
27
33
40
47

114

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Characteristic curves and performance n 2900 rpm


0

50

U.S. g.p.m.

100

200

150

100

300

n 2900 1/min
80
ft

H
m

12

200

60

MXV-E 65-3203

40

2
100

20

0
0

m3/h
l/min

10

20
200

300

30
500

400

50

40
600

700

800
2

80
Pst

Pst

60

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for the
NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

kW

40
8

NPSH

20

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity =
max 20 mm2/sec.

ft

10

Pst = Power with reference to one stage.

0
0

m /h

10

20

40

0
50

P2

Pump type
MXV-E 65 - 3202
MXV-E 65 - 3203

30

72.938

m 3/h

15

21

24

27

30

33

36

39

44

kW

HP

l/min

250

350

400

450

500

550

600

650

733

4
7,5

5,5
10

37
55,5

34
51

32
49

31
47,5

30
46

29
43,5

27
40,5

24,5
37

22
33,5

17
25,5

115

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Characteristic curves and performance n 2900 rpm


0 U.S. g.p.m. 50

200

150

100

250

100

300

n 2900 1/min
80
ft

H
m
200

60

MXV-E 80-4803

40

2
100

20

0
0

m3/h 10
l/min 200

20
300

30
400

40

500

600

700

800

60

50
900

1000

80
70

4
Pst
3
kW
2

%
60

Pst
50
40

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for the
NPSH value.
Tolerances in accordance with ISO 9906, Annex A.

1
ft

6
NPSH

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity =
max 20 mm2/sec.

ft

4
m

10

Pst = Power with reference to one stage.


0

0
0

m3/h 10

20

MXV-E 80 - 4801
MXV-E 80 - 4802
MXV-E 80 - 4803

50

72.1035

60

P2

Pump type

40

30

kW

HP

3
5,5
7,5

4
7,5
10

m3/h

21

27

33

39

45

48

51

54

60

l/min

350

450

550

650

750

800

850

900

1000

20
40,5
61

18
36
54

17
34,5
51

16
32,5
48

15
29,5
44

13
26,5
40

12
24,5
37

10,7
22
34

9,5
20
31

7
15,5
24,5

H
m

116

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Dimensions and weights


SM

Pompa
Pump
Pump

(3)

h2
(1)
(2)
DN

DN

h1
3.93.011/1

L1
L2

m2 m1

s
n2
n1

Motore
Motor

kW

HP

MXV-E 25-204
MXV-E 25-205
MXV-E 25-206
MXV-E 25-207
MXV-E 25-208
MXV-E 25-210
MXV-E 25-212
MXV-E 25-214
MXV-E 25-216
MXV-E 25-218
MXV-E 25-220

0,75
1,1
1,1
1,5
1,5
2,2
2,2
3
3
3
4

1
1,5
1,5
2
2
3
3
4
4
4
5,5

MXV-E 32-404
MXV-E 32-405
MXV-E 32-406
MXV-E 32-407
MXV-E 32-408
MXV-E 32-410
MXV-E 32-412
MXV-E 32-414
MXV-E 32-416
MXV-E 32-418
MXV-E 40-804
MXV-E 40-805
MXV-E 40-807
MXV-E 40-808
MXV-E 40-810
MXV-E 40-813
MXV-E 40-815
MXV-E 40-817

1,1
1,5
1,5
2,2
2,2
3
3
4
4
5,5

1,5
2
2
3
3
4
4
5,5
5,5
7,5

2,2
2,2
3
4
5,5
5,5
7,5
7,5

3
3
4
5,5
7,5
7,5
10
10

MXV-E (G)
bocche
filettate
threaded
threaded
ports
ports
G

ISO 228

G1

MXV-E (F)
bocche
flangiate
flanged
flanged
ports
ports
DN

L1

215

25

G11 / 2

250

32

215

G11 / 4

L2

250

40

225

280

Peso
netto
Net

mm

weight
Net
weight
h1

h2

SM

75

627
675
699
723
747
812
860
908
956
1004
1052

149
153
153
153
153
169
169
169
169
169
184

75

651
675
699
740
764
812
860
908
1000
1133

153
153
153
169
169
169
169
186
186
212

80

697
727
787
861
1026
1116
1176
1236

169
169
169
186
186
212
212
212

m1

m2

210 180

210 180

246 215

n1

n2

150

150

190

100

100

130

kg

12,5

31
38
39
43
44
53
54
56
57
59
69

12,5

38
39
42
50
51
54
55
66
67
87

14

48
49
53
64
89
91
98
99

(1) Riempimento
Filling
(2) Draining
position
of terminal
box.
(for other
positions
rotate
motoril through
90
oro180)
(3) Posizione
standard
scatola
morsetti
(altre
posizioni
ruotando
motore di
90
180)
(2) Scarico(3) Standard
Standard position of terminal box. (for other positions rotate motor through 90 or 180)
Draining
Filling

SM

mm
Pompa
Pump
Pump

(4)
G 3/8
(1)

h2

G 3/8
(3)

G 1/8
(2)
DN

kW

HP

MXV-E 50-1603
MXV-E 50-1604
MXV-E 50-1605
MXV-E 50-1606
MXV-E 50-1607

4
5,5
5,5
7,5
7,5

5,5
7,5
7,5
10
10

MXV-E 65-3202
MXV-E 65-3203
MXV-E 80-4801
MXV-E 80-4802
MXV-E 80-4803

4
7,5
3
5,5
7,5

5,5
10
4
7,5
10

weight

DN

h1

h2

SM

kg

730
824
858
893
927

186
212
212
212
212

79
80
105
112
113

741
847
745
840
901

186
212
186
212
212

82
113
73
107
115

50

300

90

65

320

105

80

320

105

(4) Posizione standard scatola morsetti (altre posizioni ruotando il motore di 90 o 180)

h1

Standard position of terminal box. (for other positions rotate motor through 90 or 180)

4.93.210/2

Flange
Flanges
Flanges

EN 1092-2 PN 25 - 40

260

220

weight
Net

(1) Filling and air vent


(2) Sfiato aspirazione (3) Draining
(1)
e sfiato
(3) Scarico
(2)box.
Sfiato
(4) Riempimento
Standard position
of terminal
(foraspirazione
other positions rotate
motor through 90 or 180)
Filling and air vent
Draining
Air vent suction side

DN

Fori - Holes

Holes

DN

DE

DK

DG

N.

165
185

125
145

99
118

4
8

19
19

200

160

132

19

DN
220

DK

50
65

260

DE

80

14

Peso
netto
Net

Motor
Motore
Motor

DG

117

12

MXV-E

Variable Speed Multi-Stage Vertical Pumps

Features

Vertical multi-stage in-line pumps


MXV-E pump series with on-board Danfoss frequency
controller.
The MXV-E series is available with motors up to 7.5 kW,
connected directly to the MXV series of vertical, in-line
multi-stage pumps (see the Calpeda general catalogue for
more information).
For units over 7.5 kW we offer panel mounted control systems.

Motor with factory programmed integrated frequency controller, series


VLT FCM 300.

Programmable Local Control Panel


with alphanumerical display.

Service plug with cable kit for a simple connection to the Local Control
Panel.
The frequency converters feature
a RS 485 connection.

Provision to connect a potentiometer to regulate the set point.

118

SPA
Compact SPA

60 Hz

Self-Draining Whirlpool Pumps


Construction
Self-draining, single-impeller pumps, with motor insulated
from pumped water, constructed with high quality, corrosion-proof plastic materials, with chrome-nickel stainless
steel diffuser.
Compact design (158 mm wide).
PVC pipe connections:
Ports for cementing joint, with external thread for union
coupling.

Applications
For spas, hydromassage bathtubs and whirlpool baths.

Operating conditions
Water temperature up to 60 C.
Room temperature up to 40 C.
Maximum permissible pressure in the pump casing: 2.5 bar.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
SPA: three-phase 220/380 V.
SPAM: single-phase 220, with thermal protector.
Capacitor inside the terminal box.

Materials
Component

Material

Pump casing
Union coupling

ABS (Acrylonitrile-Butadiene-Styrene)

Diffuser cover
Impeller

Glass reinforced
thermoplastic: PPO-GF30, NORYL*

Diffuser-wall
with wear-ring

Cr-Ni-Mo stainless steel


1.4401 EN 10088 (AISI 316)

Mechanical seal

Ceramic alumina, Carbon, FPM

Insulation class F.
Protection IP X5.
Constructed in accordance with: EN 60335-2-41, IEC 335-2-41;
EN 60335-2-60, IEC 335-2-60.

Patents:

* Trademark of General Electric

Coverage chart n = 3450 rpm


0

U.S. g.p.m.

Imp.g.p.m.

20

40

60

20

80

40

60

20
60

SPA

H
m

SPA 41
50

15
SPA 31

ft
SPA 21

40

SPA 11

10

30

20
5
10

0
0
0

m 3/h
l/min

0
5

10
100

20

15
200

300
72.596/1

119

EP 0 460 597
US 5 226 790

13

SPA
Compact SPA

60 Hz

Self-Draining Whirlpool Pumps

Performance n 3450 rpm


3~

220 V 380 V

1~

220 V

P2

IA/IN

IA/IN

kW

HP

SPA 11-60

3,1

1,8

4,8

SPAM 11-60

4,1

2,7

0,45

0,6

SPA 21-60/A

3,6

2,1

3,7

SPAM 21-60/A 5,2

3,1

0,55

0,75

SPA 31-60/A 4,5

2,6

4,5

SPAM 31-60/A 6,9

3,1

0,75

SPA 41-60

3,3

5,3

SPAM 41-60

1,1

1,5

5,7

IA/IN = D.O.L. starting current / Rated current

8,5

m3/h

12

13

16

17

18

l/min

50

100

150

200

216

266

283

300

11

10

13

12

10

H m

P2 Rated motor power output.

16,5

15

12,5

10

18

17

15,5

14

13,5

11

10,5

9,5

Tolerances according to ISO 9906, annex A.

Total head in m.

Dimensions and weights


SPA 11-60, 21-60/A, 31-60/A
f

158

70

mm

kg
m2

m3

34

26

122 167

SPA SPAM
6,7

SPA 21-60/A 371 167 191 39

31

136 172

SPA 31-60/A 371 167 191 39

31

136 172

10

146

m1

6,8

34

10

h3

h3

339 148 176

SPA 11-60

180

TYPE

3.93.070

m1
w

9
112

8
m3

m2

146

SPA 41-60

419

50

70

158

Cemented joint.

G 2 1/4
ISO 228
50

34

10
4.93.225/1

Threaded union coupling.


3.93.070

32

212

30

100

125

117

SPA 41-60 14,0 kg


SPAM 41-60 15,5 kg

155

Diffuser with peripheral-longitudinal flow,


of stainless steel for extra reliability.

4.93.035

Mechanical seal without contact with


the shaft, for extra safety.

3.93.033/1

120

180

208

146

25

MPC
Compact Pool

60 Hz

Self-Priming Swimming Pool Pumps


Construction
Self-priming swimming pool pumps with built-in strainer and
motor insulated from pumped water.
The pump is made with high quality plastic materials, corrosion and sand erosion resistant.
With chrome-nickel stainless steel diffuser.
Base-plate kit

Applications
For water circulation in swimming pool filtration systems.
For clean or slightly dirty water with solids in suspension.

Operating conditions
Water temperature up to 60 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing 2.5 bar.
Continuous duty.

14
Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
MPC: three-phase 220/380 V.
MPCM: single-phase 220.
With thermal protector up to 1.1 kW.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60 335-2-41
(IEC 335-2-41).

Materials
Component
Pump casing
Diffuser cover
Impeller
Strainer cover
Strainer basket
Diffuser funnel
with wear-ring
Mechanical seal

Material
Glass reinforced
thermoplastic
PPO-GF30, NORYL
Transparent polycarbonate, LEXAN
Polypropylene
Chrome-nickel-molybdenum stainless steel
AISI 316
Ceramic alumina, Carbon, FPM

Special features on request


- Other voltages.

Patents:

EP 0 460 597
US 5 226 790

Coverage chart n = 3450 rpm


0 U.S. g.p.m.20

40

0 Imp. g.p.m. 20

60

80

40

100

60

120

80

140

100

160

120

180
140

20
60

MPC

ft

40
10

21

71

41

20

31

61

11

0
0

3
Q m /h

l/min

6
100

12
200

18
300

24
400

30
500

36
600

0
42
700
72.859/1

121

MPC
Compact Pool

60 Hz

Self-Priming Swimming Pool Pumps

Performance n 3450 rpm


3~

220 V 380 V

1~

220 V

P2

m3/h

12

15

18

21

l/min

50
12

100
10,5

150
9

200
7

250
4,5

300

350

H
m

15

13,5

12

10

17

15,5

14

12

10

6,5

18

17

16

14,5

12,5

10

Q
MPC 11-60
MPC 21-60/A
MPC 31-60/A
MPC 41-60
3~

A
3,1

A
1,8

IA/IN
4,8

3,6

2,1

3,7

4,5

2,6

4,5

5,7

3,3

5,3

MPCM
MPCM
MPCM
MPCM

220 V 380 V

11-60
21-60/A
31-60/A
41-60

1~

A
4,1

IA/IN kW
2,7 0,37
3,1 0,55
3,1 0,75
1,1
3

5,2
6,9
8,5
220 V

HP
0,5
0,75
1
1,5

m3/h

P2

15

18

21

7,5

24

27

30

34

40

50 150 250 300 350 400


13,5 12,5 11,5 11 10,5 9,5

450
8,5

500
7,5

567
6

667

13

12

10,5

Q
MPC 61-60
MPC 71-60

A
7,7

A
4,4

10,7

6,2

IA/IN
5,8
MPCM 61-60
MPCM 71-60*
5,9

A
IA/IN
10,6 3,8

kW
1,5
2,2

HP
2
3

P2 Rated motor power output.

IA/IN = D.O.L. starting current / Rated current


MPCM 7*: on request

l/min
H
m

18

17

16

15,5 14,5

14

Tolerances according to ISO 9906, annex A.

Total head in m.

Dimensions and weights


f
ISO 228

235

215
G1 1/2 ISO 228

mm

m1
8
m2
123

(2)

w
128,5

270

190
10

(2)

MPC 11-60

m1 m2

MPC MPCM

504 348 34 122 332

8,9

MPC 31-60/A 536 367 39 136 337 11,2 12,2


9

9
112
146

(1)

MPCM 61-60 20,7 kg


MPC 61-60 19,6 kg
MPC 71-60 20,7 kg

197
215

410
L

MPCM 41-60 17,5 kg


MPC 41-60 16,0 kg

600
235
G2 ISO 228

ISO 228

584
215

235

ISO 228

kg

MPC 21-60/A 536 367 39 136 337 10,2 11,3

3.93.028

243

240

G2

TYPE

377
277
386 (3)
128,5

118
100
109

9
(1)

(2)

155

237

140
155

260

265

197
215

123

14

520

125

72

256

220
250

493

410

(1) Base-plate kit

14
55

(2)

302

12

(2)
(2)

222

302
4.93.170

3.93.072

21

270
243

10

190

240

G2

G2

G1 1/2 ISO 228

215

(2) Draining

1) Strong transparent Lexan strainer cover.

2) Strong Noryl pump casing.

3) Large 2-litre capacity strainer basket.


4) Stainless steel (AISI 316) wear-ring diffuser-funnel,
for extra reliability.
5) Diffuser with peripheral-longitudinal flow,
for a quicker self-priming.
3.93.102

4.93.035

6) Mechanical seal without contact with the shaft,


for extra safety.

3
4
122

(1)

NMP

Self-Priming Centrifugal Pumps

60 Hz

with built-in strainer

Construction
Close-coupled self-priming centrifugal pumps with built-in
strainer.
The pumps in bronze are supplied fully painted.

Applications
For water circulation in swimming pool filtration systems.
For clean or slightly dirty water with solids in suspension.

Operating conditions
Liquid temperature up to 60 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 6 bar.

15

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
NMP: three-phase 220/380 V, 380/660 V;
NMPM: single-phase 220 V.
With thermal protector up to 1.1 kW.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.

Materials
Components
Pump casing
Lantern bracket
Impeller

NMP
B-NMP
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705 for NMP 32/12
Chrome-nickel steel
Cr-Ni-Mo steel
AISI 303
AISI 316
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Chrome-nickel steel AISI 304
Carbon - Ceramic - FPM

Shaft
Strainer cover
Strainer
Mechanical seal

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Higher liquid or ambient temperatures.

Coverage chart n = 3450 rpm


30

40

20

50

30

40

U.S. g.p.m.
50

100

Imp. g.p.m.

200

300

100

200

400
300

500
400

40

NMP

120

100

30

H
ft

80

NMP 65/16
20
60

40

NMP 32/12
10

NMP 50/12
20

10

m3/h

Q l/min
100

150

20
200

300

30
400

500

40

50

100
1000

1500

120

2000
72.828.C

123

NMP

Self-Priming Centrifugal Pumps

60 Hz

with built-in strainer

Performance n = 3450 rpm


3~

1~

220V 380V

IA/IN

B-NMP 32/12FE-60

4,5

2,6

5,2

B-NMP 32/12DE-60

4,5

2,6

5,2

B-NMP 32/12AE-60

5,7

3,3

5,3

B-NMP 32/12SE-60
9
5,2
B-NMP 50/12HE-60 5,7 3,3
B-NMP 50/12GE-60
9
5,2
B-NMP 50/12FE-60 10,7 6,2
B-NMP 50/12DE-60 13 7,5
B-NMP 65/16FE-60
11,3
B-NMP 65/16EE-60
14,5
B-NMP 65/16DE-60
18,2
B-NMP 65/16CE-60
21,5
B-NMP 65/16AE-60
25

6
5,3
6
5,9
9,5
9,8
8,2
9,5
8,2
8,1

IA/IN kW HP

l/min 110
13
0,55 0,75
12
6,5 2,9 0,55 0,75
18,5
0,75 1
17,5
6,5 2,9 0,75 1
22,5
1,1 1,5
21,5
8,5 3 1,1 1,5
25
10,6 3,8 1,5 2
8,5 3 1,1 1,5
H
10,6 3,8 1,5 2
m
2,2 3
3
4
4 5,5
5,5 7,5
7,5 10
9,2 12,5
11 15

B-NMPM 32/12FE-60
B-NMPM 32/12DE-60

IA/IN

m3/h 6,6 9,6 10,8 12 13,2 15 18,9 21

P2

220V

B-NMPM 32/12AE-60
B-NMPM 32/12SE-60
B-NMPM 50/12HE-60
B-NMPM 50/12GE-60

= D.O.L. starting current / Rated current

160
12
11
17
16
21,5
20,5
24

180
11
10
16,5
15,5
21
20
23,5

200
10,1
9,1
16
15
20
19
22,5

220
9,5
8,5
15
14
19,5
18,5
22

B-NMP = Bronze construction.

30

42

48

54

60

66

75

84

96 108

500 700 800 900 1000 1100 1250 1400 1600 1800

7,5
11
15
17,5
18
20,5
26
29,5
37,5

5,5
8,5
12
15
17
19,5
25
28,5
36,5

4
7,5
10,5
13,5
16,5
19
24,5
28
36

5,5
8
11,5
15,5
18
23,5
27,5
35,5

6*
9,5*
14,5
17
23
27
35

4*
7*
13,5
16
22
26
34

11,5
14
20,5
25
32

9,5 6*
10,2 9*
18,5 14,5* 10*
22,5 20* 15*
30 27* 22*

* Maximum suction lift 2-3 m.

H Total head in m.

P2 Rated motor power output.

24

250 315 350 400


8
7
13,5
12,5
17,5
16,5
20,5 17* 14,5* 11*
9 8,8 8,5
13 12,5 12
17 16,5 16
19,5 19 18,5

Tolerances according to ISO 9906, annex A.

Dimensions and weights

f
l1

l2

DN1

DN2

h2
h1

h3
g1
4.93.067

m2

TYPE
s

m1
w

n3

B-NMP 32/12FE-60

29

32,1

n1

B-NMP 32/12DE-60

29.1

32,3

B-NMP 32/12AE-60

30.1

33,1

B-NMP 32/12SE-60

32,1

35,2

B-NMP 50/12HE-60

35,6

38,8

B-NMP 50/12GE-60

36,6

39,8

B-NMP 50/12FE-60

38,5

41,7

B-NMP 50/12DE-60

47,6

51.5

B-NMP 65/16FE-60

78.5

89

B-NMP 65/16EE-60

91

101

B-NMP 65/16DE-60

97

107

B-NMP 65/16CE-60

121

130

B-NMP 65/16AE-60

127

137

TYPE
ISO 228

B-NMP 32/12AE-60,DE-60,FE-60
G 2 G 2 195
B-NMP 32/12SE-60
B-NMP 50/12FE-60,GE-60,HE-60
G 21/2 G 21/2 205
B-NMP 50/12DE-60
B-NMP 65/16FE-60
32
G3 G3
B-NMP 65/16DE-60,EE-60
0
B-NMP 65/16AE-60,CE-60

h1 h2 h3

B-NMP
kg

n2

mm

DN1 DN2

NMP
kg

H m1 m2 n1 n2 n3

510 230 280 210 320 100 70 190 140 30 50 14


540
222
37
262 322
360 100 70 240 190
50 14
602
240
20
717
288
60
36 44
47 12
28 21
748 0 0 320 0 5 95 0 2 49 65 14
43
858
345

124

l
-

l1

l2

g1

106 99 220 12
234
12
298
298
16
165 4 319 15
408
120 117

NMP

Self-Priming Centrifugal pumps

60 Hz

with built-in strainer

Characteristic curves n = 3450 rpm


30

0 U.S. g.p.m. 20
0 Imp.g.p.m. 20
 116
 114

m
20

40

60

40

50

80

60

100
80

20



55

80
ft
60

D 57.5%

 103

55

50

 88

40

10

10

15

25

20

1.5
P
1
kW
0.5





0
12
NPSH
8
m
4
0

40
m
30
20

10

0 U.S. g.p.m. 100


0 Imp.g.p.m. 100

15

200

300
200
50 55
57.5

 152
 136
 129

20

300

72.599

400

D 60%

57.5

55

116

3
P
2
HP
1

120
100
ft
80

40

10

20
40

60

80

12
P
8
kW
4
0
11
9
NPSH
7
m
5
3
0  m3/h 20

30
NPSH
20
ft
10
0
25

60

 112

0
0  m3/h 20
16

50

100

0
120
20

P

HP

10
0

40

60

80

100

m
15

 105

10

84

55

D 57.5%

 94

0
0  m3/h
5
4
P
kW
2
1
0
10
8
NPSH
6
m
4
2
0  m3/h

500
400



 110

100
50

200

300

200

60


55

50

50
ft
40

45

30
20

0  m3/h 5

100

45

20
0
0  m3/h 5
2

0 U.S. g.p.m.
0 Imp.g.p.m.

30
NPSH
20
ft
10
72.601
120
125

10
20

40




20

40

80

60

60

0
6
5
P
HP
3
2
1
0

30
NPSH
20
ft
10
72.600
80

15

PF

Pre-filters in stainless steel

Construction
Pre-filters with removable basket, constructed in stainless
steel.
Loose ring flange connections.
Clamp type closing with lever and double adjustment clamp.
Inner basket with 6 mm holes.

Applications
For water circulation pump in filtration plants in swimming
pools.
To prevent foreign bodies from entering the pump and the
plant.

Operating conditions
Max working pressure: 3 bar.
Max flow: 180 m3/h for PF 100.
240 m3/h for PF 125.
300 m3/h for PF 150.

Materials
Components
Pre-filter body PF 100-304
PF 125-304
PF 150-304
Pre-filter body PF 100-316
PF 125-316
PF 150-316
Strainer basket

Diagram of head loss

Materials

16

Stainless steel AISI 304

Stainless steel AISI 316


Stainless steel AISI 316

Dimensions and weights


D

(1)

PF 100

PF 125

PF 150

DN

DN

h2

h1
4.93.206.1

(2)

FlangesUNI
UNI6089
6089PN
PN10
10
Flange
mm

Type
Tipo

DN

Q m3 /h 50

100

150

200

250

PF 100

100

PF 125

125

PF 150

150

h1

h2

530

247

287

550

260

300

440

292

185

17,5

440

292

185

17,7

500

350

210

23,3

300

H = Head loss in meters

1 Relief valve

127

kg

2 Draining plug

PF

Pre-filters in stainless steel

Recomended pumps and pre-filters

Pump
NM 80/16EE
NM 80/16CE-DE
NM 80/16BE
NM4 100/20BE-CE
NM4 100/20AE
NM4 100/25BE
NM4 100/25AE
NM4 125/25DE-EE
NM4 125/25CE
NM4 125/250AE-BE

Pre-filter
type

h
mm

PF 100

67

PF 125

47

PF 125

22

PF 150

10
10
-

NM 80/16BE-CE-DE-EE
NM4 100/20AE-BE-CE
NM4 100/25AE-BE
NM4 125/25CE-DE-EE
h

NM4 125/250AE-BE
4.93.181

Examples of installations
Operation with positive suction head

Operation with suction lift

4.93.205.1

4.93.205.2

1 Gate valve

2 Pressure gauge

3 Check valve

4 Foot valve

128

Self-Priming Centrifugal Pumps

60 Hz

with open impeller

Construction
Close-coupled centrifugal pumps with open impeller.
The built-in backflow preventer avoids reverse siphoning when
the pump is stopped and assures automatic re-priming at the
next start.
The pump re-primes itself even if partially filled with liquid and
with completely empty suction pipe.
The pumps in bronze are supplied fully painted.

Applications
For clean or slightly dirty water, also with solids up to 10 mm
grain size for A 40, A 50 and 15 mm for A 65, A 80.
For draining a basin or a sump.
For irrigation.
For civil and industrial applications.

Operating conditions
Liquid temperature from -10 C to +90 C.
Room temperature up to 40 C.
Maximum permissible working pressure up to 6 bar (10 bar for
A 80-170).
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
A: three-phase 220/380 V, 380/660 V;
AM: single-phase 220 V, with thermal protector up to 1.1 kW.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.

Materials
Components
Pump casing
Suction flange
Inspection cover
(for A 65, A 80)

Lantern bracket
Impeller
Shaft

Mechanical seal

B-A

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Special features on request


Other voltages.
Protection IP 55.
Special mechanical seal.
Higher or lower liquid or ambient temperatures.
Explosion proof construction in accordance with Directive 94/9
EEC (ATEX).
Construction with bearing bracket.

Chrome-nickel steel
1.4305 EN 10088 (AISI 303)

Cr-Ni-Mo steel
Chrome steel 1.4104 EN 10088 1.4401 EN 10088 (AISI 316 )
(AISI 430) for A 65-150AE,BE
Carbon - Ceramic - NBR

Coverage chart n 3450 rpm


0

Imp. g.p.m.

50

100

150

200

250

40
120

100

30

A 80-170

ft

80

20

A 65-150

60

40

A 50-125

10

A 40-110

0
m 3/h
0 Q l/min

10
200

20

20
300

400

30
500

40
600

700

50
800

900

60
1000

70
1100
72.829.C

129

17

Self-Priming Centrifugal Pumps

60 Hz

with open impeller

Performance n 3450 rpm


3~

220V 380V
A

A 40-110B-60/A
B-A 40-110B-60/A

3,6

A 40-110A-60/A
B-A 40-110A-60/A

4,5

3~

A
2,1
2,6

1~
IA/IN
3,7
4,5

220V 380V

220 V

P2

IA/IN

AM 40-110B-60/A
B-AM 40-110B-60/A

5,2

3,1

AM 40-110A-60/A
B-AM 40-110A-60/A

6,9

1~

kW

m3/h

3,6

4,8

7,5

8,4

9,6

10,8

12

15

18

l/min

60

80

100

125

140

160

180

200

250

300

12,5

12

11,3 10,5

10

9,4

8,6

7,8

5,4

15,5

15

14,5 13,7 13,2 12,5 11,8 11,1

9,1

6,7

12

15

18

21

24

27

30

33

150

200

250

300

350

400

450

500

550

13,5

13

12

11

9,5

16,5

16

15

13,5

12

10,5

19,5 18,5 17,5

16

14,5

13

11

18

24

30

33

36

42

48

54

57

300

400

500

550

600

700

800

900

950

19

17

15,5 14,5

13

11

6,5

20

18,5

17

16

13,5

10

Q
HP

0,55 0,75

Hm
3,1

0,75

220 V

m3/h

P2

Q
A

IA/IN

kW

HP

5,2

6,5

2,9

0,75

3,3

5,3

AM 50-125BE-60
B-AM 50-125BE-60

8,5

1,1

1,5

5,2

AM 50-125AE-60
B-AM 50-125AE-60

10,6

3,8

1,5

4,5

2,6

A 50-125BE-60
B-A 50-125BE-60

5,7

A 50-125AE-60
B-A 50-125AE-60

3~

IA/IN
AM 50-125CE-60
B-AM 50-125CE-60

A 50-125CE-60
B-A 50-125CE-60

220V 380V

l/min 100

Hm

20

m3/h

P2

15

Q
A

IA/IN

kW

HP

A 65-150CE-60
B-A 65-150CE-60

10,7

6,2

5,9

2,2

A 65-150BE-60
B-A 65-150BE-60

13

7,5

9,5

A 65-150AE-60
B-A 65-150AE-60

11,3

9,8

5,5

3~

220V 380V

P2

IA/IN

kW

HP

A 80-170B-60
B-A 80-170B-60

14,5

8,2

5,5

7,5

A 80-170A-60
B-A 80-170A-60

l/min 250
19,5

Hm

m3/h

22,5 21,5
31

30,5

29

27

26

25

22,5

19

15

11,5

15

18

21

24

30

36

45

54

60

66

300

350

400

500

600

750

900 1000 1100

l/min 250

29,9 29,8 29,7 29,3 28,2 26,6 23,8 20,3 17,3

Hm
18,2

9,5

P1 Maximum power input.

B-A, B-AM = Bronze construction.

P2 Rated motor power output.

H Total head in m.

7,5

10

35,5 35,5 35,2

35

Tolerances according to ISO 9906, annex A.

130

34,4 33,2 30,9 27,6 25,4

Self-Priming Centrifugal Pumps

60 Hz

with open impeller

Characteristic curves n 3450 rpm


20

40

60

80

0 U.S. g.p.m.

A 40-110

18
16
14

50

B 90

30

60

120

80

100

Q m /h

l/min

10
100

15

20

200

70
60

55
56%
55

C 94

ft
50
50

40
45

10

120

A 50-125

40

B 100

10

140

50

15

30

0
20
5

300

10
A

0,6

1,0

0,4

P HP

0,8

P kW

100

20

0,5

0
2

Q m3/h

10

20

30

P
kW

0,2
0

B
1

60

(%)

80

17

40

HP

20

0
8
20

4
10

2
0
3

Q m /h

10

0 U.S. g.p.m. 50
0 Imp.g.p.m.

100
50

15

150
100

5
0

10

Q m3/h

0 U.S. g.p.m.50

250

150

25
NPSH
ft
15
10

20

200

0
0

NPSH
m
4

NPSH ft

20

100

150

30

200

250

A 145

200
120

57.5

80

ft
80

20

60

57.5
55

C 112

20

100

100
59%

B 116

B 136

30

Hm

55

120

A 80-170

A 65-150
30

300

40

40

A 133 50

72.603

H ft

Hm

A 107

NPSH m

40

20

40

10

1,0

60

24

12

40

0 Imp. g.p.m.

60

A 99

H ft

0 U.S. g.p.m.
20

40
10

60

50
45

20
40
0

0
0

20

20

30

40

60

50

P kW

Q m3/h 10

A 6
5
P
HP
3

3
P
2
kW
1

2
1

4
2

NPSH m

30
NPSH
20
ft
10

Q m3/h

10

20

30

40

50

72.604

800

70

1000
10

A
B

8
6

40

0
10

30

8
6

20

4
10

2
0

0
0

600

60

20

12
NPSH
m
8

400

50

60

(%)

200

40

30

0
0

l/min

20

0
0

60

131

3
Q m /h 10

20

30

40

50

60

70

NPSH ft

3
Q m /h 10

P HP

10

Self-Priming Centrifugal Pumps

60 Hz

with open impeller

Dimensions and weights


393
132
83

G 1 1/2

89

kg

G 1 1/2

208

ISO 228

ISO 228

275
206

19,8
20,8

A 40-110B-60/A
AM 40-110B-60/A

18,9
19,8

B-A 40-110A-60/A
B-AM 40-110A-60/A

22,5
23,5

B-A 40-110B-60/A
B-AM 40-110B-60/A

21,6
22,5

A 50-125AE-60
AM 50-125AE-60

29,9
31

A 50-125BE-60
AM 50-125BE-60

28
29,1

A 50-125CE-60
AM 50-125CE-60

26,9
27,8

B-A 50-125AE-60
B-AM 50-125AE-60

33,6
33,6

B-A 50-125BE-60
B-AM 50-125BE-60

31
32,6

B-A 50-125CE-60
B-AM 50-125CE-60

29,6
30,6

50

16

70
100

A 40-110A-60/A
AM 40-110A-60/A

140
190

199

490
102

96

147

kg

G2

G2

231

ISO 228

ISO 228

295
223
14
4.93.103

30

16

70
100

50

140
263

190

f
172

115

121

G 2 1/2
ISO 228

mm

G 2 1/2

293

ISO 228

TYPE

368
h3
14
4.93.102

47

16

95
125

kg
f

h3

A 65-150CE-60
B-A 65-150CE-60

543

260

279

46
47,5

A 65-150BE-60
B-A 65-150BE-60

595

260

324

54
55,5

A 65-150AE-60
B-A 65-150AE-60

595

260

324

58
59,5

50

190
w

240

659
202
132

G3

140

ISO 228

G3
342

ISO 228

kg
A 80-170A-60

85,3

A 80-170B-60

79,3

B-A 80-170A-60

95,1

B-A 80-170B-60

89,1

432
317

18

110
145

22
352

47
220
280

132

60

Centrifugal Pumps

60 Hz

with open impeller

Construction
Close-coupled centrifugal pumps with open impeller.
Free-flow impeller (vortex or recessed impeller) for type C 16/1E.
The pumps in bronze are supplied fully painted.

Applications
For moderately dirty liquids or emulsions.
For industry and agriculture.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 8 m.
Maximum permissible working pressure: 6 bar.
Maximum size of solids: 4 mm.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
C:
three-phase 220/380 V.
CM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.

Materials
Component
Pump casing

C
B-C
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
Chrome steel AISI 430
Cr-Ni-Mo steel
Cr-Ni steel AISI 303
AISI 316
for C 41E
Carbon - Ceramic - NBR

Lantern bracket
Impeller
Shaft

Mechanical seal

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


3
2

4
3

10

U.S. g.p.m.

20

30

10

Imp. g.p.m.

20

50

40
30

40

50

24

C 22E-60

C 41E-60

B-C 22-60/A

20

B-C 41E-60

C 4-60/A

C 22/1E-60

B-C 41/1E-60

B-C 22/1-60/A

60

C 4/1-60/A

16

C 20E-60
B-C 20-60/A

12

40

H
ft

C 16/1E-60

20

B-C 16/1E-60

0
0.5
10

m 3/h
l/min

1
20

30

3
40

50

10
100

20
200

300
72.834.C

133

18

Centrifugal Pumps

60 Hz

with open impeller

Performance n = 3450 rpm


Q
3~

1~

220V 380V
A

C 16/1E-60
B- C 16/1E-60

IA/IN

3,6

2,1

3,7

C 4-60/A
4,5
B- C 41/1E-60 4,5

2,6
2,6

4,5
5,2

CM 4-60/A
6,9
B- CM 41/1E-60 6,5

5,3

CM 41E-60
B- CM 41E-60

5,7

3,3

CM 20E-60
B- CM 20-60/A

CM 4/1-60/A

1,5

1,8

2,4

3,6

4,8

HP l/min

10

15

20

25

30

40

50

60

80

4,7

4,4

4,2

3,3

5,2

12,3 12,2 12 11,5 10,8

8,5

1,1

8,4

9,6 10,8 12 13,2 15

100 110 140 160 180 200 220 250

16 15,8 15,5 15,1 14,3 13,5 12,2 11

9,5

19 18,8 18,5 18,3 17,7 17,2 16,5 15,5 14,4 12,5

1,5

22,6 22,3 22,1 22 21,5 21 20,3 19,5 18,5 17


= Density 1000 kg/m3 .

Tolerances according to ISO 9906, annex A.

= Kinematic viscosity max 20 mm2/sec.

H Total head in m.

= D.O.L. starting current / Rated current.

6,6

22,5 22,5 22,4 22 21,5 19,5

H
m

3,1 0,55 0,75


3,1
0,75
2,9

19,5 19,4 19,1 18,7 17,9 15,3

B-C, B-CM = Bronze construction.

P2 Rated motor power output.


IA/IN

1,2

2,5
0,37 0,5
2,3
2,7
0,45 0,6
2,5
2,6
0,55 0,75
3,1

3,5
3,5
3,8
3,5
4,5
3,7

C 41E-60
B- C 41E-60

0,9

3,1
3,4
CM 22/1E-60 3,4
B- CM 22/1-60/A 4,1
4,3
CM 22E-60
B- CM 22-60/A 5,2

1,3
1,5
1,7
1,5
2
2,1

C 4/1-60/A

0,6

2,7 0,15 0,2

2,3
2,6
C 22/1E-60 3
B- C 22/1-60/A 2,6
3,5
C 22E-60
B- C 22-60/A 3,6

IA/IN kW

m3/h

CM 16/1E-60
1,5
B- CM 16/1E-60

1,2

C 20E-60
B- C 20-60/A

P2

220V

Dimensions and weights


263

266

l1

34

33
G 1/2

ISO 228

G1

75

ISO 228

G 1/2

ISO 228

ISO 228

h2

160

160
8 63

TYPE
C 16/1E-60
CM 16/1E-60

4.93.222

22

7
80

100

96

122

kg

7
88

TYPE

5,2
5,2

8 63

h4

4.93.221

93

l2
l3

G1

122

kg

B-C 16/1E-60
B-CM 16/1E-60

TYPE

5,6
5,6

22

80
96

100
122

h2
90
110

C 20E-60
C 22/1E-60 - C 22E-60

h4
5
17

mm
l1
67
77

l2
82
94

l3
60
71

kg
C
CM
6,8
6,8
8 - 8,3 8 - 8,3

f
a

l1

l2
l3

DN 1

DN 2

h2
h3
g h1

h4
s
m2
m1

4_93_223

DN1 DN2

b
n2
n1
mm

kg

TYPE
ISO 228

h1

h2

h3

h4

m1

m2

n1

n2

l1

l2

l3

CM

B-C

B-CM

B-C 20-60/A

G1

G1

35

303

71

90

182

106

90

134 112

22

70

84

60

105

10

9,1

9,1

B-C 22/1-60/A
B-C 22-60/A

G1

G1

35

303

71

110 182

106

90

134 112

22

81

93

71

106

10

10,5
10,8

11,5
11,8

C 4/1-60/A

C 4-60/A

G 11/2 G 11/2

43

304

71

160 182

18

106

90

134 112

22

85

108

78

100

10

10,8
11,8

11,8
12,8

B-C 41/1E-60
C 41E-60 B-C 41E-60

G 11/2 G 11/2

43

380

80

160 190

125 100 155 125

30

9,5

85

108

78

132

10

16,7

17,7

17,4
18,5

18,6
19,3

134

Centrifugal Pumps

60 Hz

with open impeller

Characteristic curves n = 3450 rpm


0 U.S. g.p.m. 2
0 Imp. g.p.m.

0 U.S. g.p.m. 5

10

0 Imp. g.p.m.

10
5

15
10

20

25

15

20

15
22

C 16/1

54

m
5

20

18
ft

10

C 20

85

40
ft
30

16
14

20

4
5

12
10

10

8
2

0
0

0,10

Q m3/h 0.5

1.5

2.5

0
0.4

Q m3/h 1

0.5

0.12

P
kW

0.3
P
0.2
kW
0.1

0.10
P
HP

0,06

0,06

0,04

0.4
P
0.3
HP
0.2
0.1

0,04
0

0,02
6

NPSH
4
m
2

12

NPSH
3
m

16
NPSH
ft
8

10
NPSH
8
ft
6

4
0

Q m3/h 0.5

0 U.S. g.p.m. 5
0 Imp. g.p.m.

1.5

10
5

15
10

72.620

20

2.5

25

15

20

25
80
C 22 106

C 22
C 22/1

70
ft

C 22 /1 101

20

60

50

15

40
10
0
0.8

Q m3/h 1

1.0
0.6
P
0.4
kW
0.2

C 22

0.8
P
0.6
HP
0.4

C 22 /1

0.2

2.4
7.5
NPSH
7
ft
6.5

NPSH
2.2
m
2.0

1.8
0

Q m3/h 1

72.624

0
0

135

Q m3/h 1

72.622

18

Centrifugal Pumps

60 Hz

with open impeller

Characteristic curves n = 3450 rpm


0 U.S. g.p.m.

30

20

0 Imp. g.p.m.

20

40
30

50

70

60

40

0 U.S. g.p.m.
0 Imp. g.p.m.

50

30

20
20

40
30

50

70

60
50

40

25

20

80

C4

60

C 4/1

94

70

B-C 41/1

20

ft

102

50

15

60

ft
50

15

40

40

10
30

10
30

20

20

5
0

Q m /h
3

16

12

0
1.2

1.0
P
kW
0.6

1.2

1.0

1.0
P
HP

P
kW
0.6

Q m /h
3

16

12

1.6
1.4
P
HP
1.0
0.8

0.6

0.4

0.6

0.4
0.4

0.4
0.2

0.2
8

25
20
NPSH
ft
10

6
NPSH
4
m
2

0
0

Q m3/h

30

20

0 U.S. g.p.m.
0 Imp. g.p.m.

20

12

40
30

50

72.623

50

25

80
108

C 41

70

20

ft
60
50

15

40
10
30
20
5
0
1.4

Q m3/h

16

12

1.8

1.2

1.6

P
kW
0.8

1.4
P
HP
1.0

0.6

0.8

0.4

0.6

25
20
NPSH
ft
10

6
NPSH
4
m
2

0
0

Q m3/h

12

72.626

16

20
NPSH
ft
10
5

70

60

40

16

25

6
NPSH
4
m
2

136

Q m3/h

12

72.625

16

CT 61 60 Hz

Peripheral Pumps
with turbine impeller

Construction
Close-coupled peripheral pump (regenerative pump) with
turbine impeller.
Compact, patented construction with movable casing cover
motor side (replaceable in case of wear).
Protected against water entering the motor from outside.
The pumps in bronze are supplied fully painted.

Applications
For clean liquids without abrasives, without suspended
solids, non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable to be mounted in cooling and air-conditioning machines
and equipments, circulation.

Operating conditions
Liquid temperature up to 60 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Continuous duty.

Materiales (wetted parts)


CT 61
Components
Pump casing
Pump-side motor wall
Impeller
Shaft
Mechanical seal

Coverage chart n = 3450 rpm


U.S. g.p.m.
0

10

50

160

Material
Cast iron GJL 200 EN 1561
Brass P- Cu Zn Pb 2 UNI 5705
Brass P- Cu Zn Pb 2 UNI 5705
Chrome-nickel steel AISI 430
Carbon - Ceramic - NBR

140
40

B-CT 61
120

Hm

80
20

H ft

100

30

60
40

2-pole induction motor, 60 Hz (n = 3450 rpm).


CT 61:
three-phase 220/380 V.
CTM 61: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: (EN 60335-1)

20

0 Q m 3/h
0
l/min
0

l/s

1
8
0.1

12

16

0.2

20
0.3

24
0.4

28

32

36

0.5

2.6

Material
Bronze G-Cu Sn 10 EN 1982
Brass P- Cu Zn Pb 2 UNI 5705
Brass P- Cu Zn Pb 2 UNI 5705
Chrome-nickel steel AISI 430
Carbon - Ceramic - NBR

Motor

10

Components
Pump casing
Pump-side motor wall
Impeller
Shaft
Mechanical seal

40

0.6

0.4
0.5

0.2

0.4

Special features on request

0.3

- Other voltages.
- Special mechanical seal

P HP

P kW

0.3

0.2
0.1

0.1

20

6
5

15

4
10

3
2

Q m 3/h

2.6

137

NPSH ft

NPSH m

19

CT 61 60 Hz

Peripheral Pumps
with turbine impeller

Performance n = 3450 1/min


3~

220V 380V
A
A IA/IN

CT 61-60
B-CT 61-60
IA/IN

2,3

1,3

3,2

1~

Q
220V
P2
A IA/IN kW HP

CTM 61-60
B-CTM 61-60

3,1

= D.O.L. starting current / Rated current

H Total head in m.

2,5

m3/h
l/min

0,5
8,3

0,6
10

39

36

0,33 0,45

P2 Rated motor power output.

0,75 0,96
12,5 16
33

29

1,2
20

1,5
25

1,89
31,5

2,3
38

24

18

12

B-CT = Bronze construction.

Tolerances according to ISO 9906, annex A.

Dimensions and weights


198

G1 ISO 228

58

22

63

kg
kg
kg
kg

4,6
4,7
4,9
5

108

CT 61-60
CTM 61-60
B-CT 61-60
B-CTM 61-60

158

90

G1 ISO 228

4.93.159

22

100

80

122

96

Features

Patented
4.94.160/1

138

40.5

T, TP

Peripheral Pumps

60 Hz

with turbine impeller

Construction
Close-coupled peripheral pumps (regenerative pumps) with
turbine impeller.
The pumps in bronze are supplied fully painted.

Applications
For clean liquids without abrasives, without suspended
solids,non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable to be mounted in cooling and air-conditioning machines
and equipments, circulation, boiler feed.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
T, TP: three-phase 220/380 V.
TM, TPM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.

Materiales
Components
Pump casing
Lantern bracket
Casin cover

Impeller
Shaft

Mechanical seal

T, TP
B-T, B-TP
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705 for T 61-65-70, B-T 61-70
Brass P- Cu Zn 40 Pb 2 UNI 5705
Bronze G-Cu Sn 10 EN 1982 for T 125, TP 132-132R
Chrome-nickel steel AISI 303
for T 76, Tp 80-100
Cr-Ni-Mo steel
AISI 316
Chrome steel AISI 430
for T 61-65-70-100-125, Tp 78-132-132R
Carbon - Ceramic - NBR

Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034;
IEC 60335-1 (EN 60335-1)

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


0

U.S. g.p.m.

Imp. g.p.m.

10

15

20

10

25

15

20

180
TP 132E-60
TP 100E-60

150

T, TP
500

TP 132RE-60 T 125E-60

H
H

ft

400
T 100E-60

100
300
TP 80E-60
200
50
100

T 76E-60
TP 78-60/A
T 61E-60
0

0
0

m 3/h

Q l/min 10

2
20

30

40

T 70-60/A

T 65E-60
3
50

4
60

5
70

80

90

6
100
72.831.C

139

20

T, TP

Peripheral Pumps

60 Hz

with turbine impeller

Performance n = 3450 rpm


3~

A
2,4
3,1
4,5
6,4

A
1,4
1,8
2,6
3,7
11,3
14,5
2,6 1,5
4,5 2,6
11,5 6,6
18,2
18,2

B- T 61E-60
T 65E-60
B- T 70-60/A
T 76E-60
T 100E-60
T 125E-60
B- TP 78-60/A
B- TP 80E-60
TP 100E-60
TP 132RE-60
TP 132E-60
IA/IN

1~

220V 380V

IA/IN
3,2
4,8
4,5
4,9
9,8
8,2
3,5
5,2
5,1
9,5
9,5

P2

220V

Q
m3/h 0,06 0,12 0,24 0,38 0,48 0,6 0,75 1

A IA/IN kW HP l/min 1
3,1 2,5 0,33 0,45
4,2 2,6 0,45 0,6
3 0,75 1
7,2
3
8,5
1,1 1,5
4
5,5
H
5,5 7,5
m
2,3
74
3,4
B- TPM 78-60/A
0,37 0,5
B- TPM 80E-60 6,5 2,9 0,75 1
2,2
3
7,5 10
7,5 10

6,3 8
36 34

B- TM 61E-60
TM 65E-60
B- TM 70-60/A
TM 76E-60

60

50

3,6 4,2 4,8 5,4

20 25 31,5
21 16,5 11
33 29 24
48 43 38
60 55 50

50

60

40
5
16
30
45
100
140

8
22
35
95
130

70

80

90 100

10
25
85 80 75
115 100

34 25
75 70 55 45 30 20
145 135 125 115 100 80 60
140 130 120 105 95

42

160 140 120


H Total head in m.

B-T, B-TM = Bronze construction.

= D.O.L. starting current / Rated current

P2 Rated motor power output.

69

10 12,5 16
32 30 26
40 37

1,2 1,5 1,89 2,4

* Maximum suction lift 2-3 m.

Tolerances according to ISO 9906, annex A.

Dimensions and weights


f
244
24
G1 ISO 228

58

l2
DN2

G1

G1
ISO 228

DN2

ISO 228

DN1
90

h2
182

160
108

80

7
80
96

h3

8 63

4.93.227

22
100
122

10 71

4.93.218

7
93

T 61E-60: kg 5,6
B- T 61E-60: kg 6,4

22

90

112

106

134

DN1 DN2

mm

kg

TYPE
ISO 228

T 65E-60: kg 6,7

T 70-60/A B-T 70-60/A G 1 G 1 24


TP 78-60/A B-TP 78-60/A G 1/2 G 1/2 22

h2

h3

l2

278 100 121


276 80 127

63
56

B-T

10,5 11,6
8,2 8,8

f
l2

a
DN2

DN2
DN1
h2
h4
h3
g h1

TYPE

DN1

4.93.093

s
m2
m1

b
n2
n1

kg

mm

DN2

ISO 228

h1

h2

h3

h4

m1

m2

n1

n2

l1

l2

T 76E-60

G 11/4 G 11/4

26

338

80

112

136

185

117

100

155

125

30

80

105

10

17,2

T 100E-60

G 11/4 G 11/4

32

410

90

130

161

216

152

125

180

140

40

9,5

95

121

12

33

T 125E-60

G 11/4 G 11/4

32

505

112

155

192

272

180

140

230

190

50

11,5

90

209

14

39

TP 80E-60 B-TP 80E-60

G 3/4

G 3/4

27

332

80

90

135

185

117

100

155

125

30

60

104

10

15,5

16,1

TP 100E-60

G 3/4

G 3/4

27

347

80

100

142

185

117

100

155

125

30

65

113

10

20,2

14

62
62

TP 132RE-60
TP 132E-60

G 11/4 G 11/4

42

485

112

160

202

272

180

140

140

230

190

50

11,5

100

183

T, TP B-TP

T, TP

Peripheral Pumps

60 Hz

with turbine impeller

Characteristic curves n = 3450 rpm


0

U.S. g.p.m.

0 Imp. g.p.m.

10

12

U.S. g.p.m.

0 Imp. g.p.m.

10

50

10

12
10

50
150

H
40

T 65E

40

ft

150

T 61E

ft
65

60
100

30

100

30

20

20
50

50

10

10

0
0

0.5

Q m3/h

0
0

0.7
0.6

0.4
P
kW

0.4

0.6
P
kW

HP

0.4

0.2

Q m3/h

0.9
0.8
P
0.6
HP

0.2
0.1
0

0.3

0.4

0.2

0.3

8
20

6
NPSH
4
m
2

10
ft

0
0

Q m3/h

0 U.S. g.p.m.
0 Imp. g.p.m.

72.606

10
5

20

6
NPSH
4
m
2

NPSH

NPSH
10
ft

0
3

15
10

70

Q m3/h

U.S. g.p.m.

Imp.g.p.m.

72.607

10

0
3

15

10

80

T 70/A

60

H
50
m

200

ft

m
60

T 76E
200
ft

150
71

40

76
40
100

30

100
20

20

50
10
0
0
1.2

Q m3/h

1.6

1.4
P
HP

1.0
P
kW

0
0

0.8

0.4

0.6

2
P
P

1
kW

1.0

0.6

Q m 3/h

1
HP

NPSH
4
m

16
NPSH
ft
8

2
0
0

Q m3/h

72.608

6
NPSH
4
m
2

20
NPSH
10
ft
0

141

Q m 3/h

72.609

20

T, TP

Peripheral Pumps

60 Hz

with turbine impeller

Characteristic curves n = 3450 rpm


0 U.S. g.p.m.
0 Imp.g.p.m.

2
1

0 U.S. g.p.m.

0 Imp.g.p.m.
140

80
77,5

TP 78/A

200

ft

8
6

400

TP 80E

120

60

ft
100
300

40

78
200

60
100
40

20

100
20

0
0

0.6

Q m3/h 0.2

0.4

0.6

1.0

0.8

0
0

1.8

0.8

0.5
P
0.4
kW
0.3

0.7
P
HP
0.5

0.2

0.3

Q m3/h

0.5

1.5

2
2.2
P
1.8
HP
1.4

P
1.2
kW
0.8

0.4

1.0
0.6

0.4
6

6
NPSH
4
m
2
0
0

NPSH
4
m

15
NPSH
10
ft
5

Q m3/h 0.2

0 U.S. g.p.m.

0.4

0.6

0 Imp.g.p.m. 2
200

0.8

10

72.610

16
12
NPSH
8
ft
4

2
0

1.0

Q m3/h

12

U.S. g.p.m.

10

Imp.g.p.m.

0.5

72.611

1.5

10

0
2

20
10

20

150

T 100E

140

600

TP 100E

180
m
160

ft

130

500
140
97

120

ft

m
110

400

100

400

96
300

90

100
300

80

80
70
200

60

200

60
50

40
0
4

Q m3/h

0
8

Q m 3/h

5
3
P
2
kW
1
0
8

5
kW
4

2
0

Q m3/h

72.612

6
5

10
30
8
NPSH
6
m
4

20
NPSH
15
ft
10

9
P
HP
7

25

NPSH
6
m

10

4
P
HP
2

NPSH
20
ft
10

2
3

142

Q m 3/h

72.613

T, TP

Peripheral Pumps

60 Hz

with turbine impeller

Characteristic curves n = 3450 rpm


0 U.S. g.p.m. 5
5
0 Imp.g.p.m.

10

15

10

15

700

T 125E

200

118

0 Q m /h 1
9
8
P
kW
6
5
4
10
8
NPSH
6
m
4
2
0 Q m3/h 1

160
120

72.614

15

20

20

25
1000

TP 132
Tp 132E
Tp 132-RE 132 sp.7.6

132 sp.8.1

40
0 Q m3/h 1
18
P
kW
12

12
P
10
HP
8

200
2

6
22
18
P
14
HP
10
6

Tp 132E

Tp 132-RE

8
4
12
NPSH
8
m
4

30
NPSH
20
ft
10

143

0 Q m3/h 1

800
ft
600
400

80

10

200

300
3

15

400
100

10

280
m
240

600
ft
500

m
150

0 U.S. g.p.m. 5
0 Imp.g.p.m. 5
320

20

72.615

30
NPSH
20
ft
10
0

20

CA

60 Hz

Self-Priming Liquid Ring Pumps


Construction
Close-coupled self-priming liquid ring pumps with star
impeller.
The pumps in bronze are supplied fully painted.

Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
If the liquid to be pumped has entrained air or gas or the flow
in the suction pipe is not stable.
For drawing water out of a well.
For increasing network pressure (follow local specifications).

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Negative suction pressure up to 9 m.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
CA:
three-phase 220/380 V.
CAM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with IEC 60034.

Materials
Components
Pump casing
Lantern bracket

CA
Cast iron
GJL 200 EN 1561

Impeller
Shaft

B-CA
Bronze
G-Cu Sn 10 EN 1982

Mechanical seal

21

Special features on request

Brass P- Cu Zn Pb 2 UNI 5705


Chrome steel
Cr-Ni-Mo steel
AISI 430
AISI 316
Carbon - Ceramic - NBR

- Other voltages.
- Protection IP 55.
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.

Coverage chart n = 3450 rpm


U.S. g.p.m.

0.5
0.4

0.5

Imp. g.p.m.

10

10

60

CA

50

150

40

ft

CA 90-60/A
100

30

CA 80-60/A
20
50

CA 60E-60
10

0
0.1

0.2

m 3/h

Q l/min

0.3
4

0.4

0.5

1
10

20

30

3
40

50
72.830.C

145

CA

60 Hz

Self-Priming Liquid Ring Pumps

Performance n = 3450 rpm


3~

220 V 380 V
A

CA 60E-60
B-CA 60E-60

1,2

CA 80-60/A
B-CA 80-60/A

3,6

CA 90-60/A
B-CA 90-60/A

4,5

IA/IN

1~

220 V

IA/IN

P2

IA/IN kW

HP

CAM 60E-60
2,8
B-CAM 60E-60

2,7 0,33 0,45

2,1

3,7

CAM 80-60/A
5,2
B-CAM 80-60/A

3,1 0,55 0,75

2,6

4,5

CAM 90-60/A
6,9
B-CAM 90-60/A

3,1 0,75

m 3/h 0,12 0,24 0,38 0,48 0,6 0,75 0,9

1,2 1,5 1,89 2,1 2,4 2,5

l/min

16

20

25 31,5 35

27

6,3

10 12,5 15

29

27

24

22

18

43

42

40 37,5 36

34

31

53

47

42 36,5 29 25

H
m

P2 Rated motor power output.

= D.O.L. starting current / Rated current.

40 41,6

10

14

48

50

19 15
20

H Total head in m.

B-CA = Bronze construction.

Dimensions and weights


f

l2

l3

DN2
DN1

h2
h4
h3
g
4.93.217

s
w

DN1

TYPE

h1

m2

n2

m1

n1

mm

DN2

ISO 228

kg

h1

h2

h3

h4

m1

m2

n1

n2

l2

l3

CA

B-CA

65

103 158

96

80

122 100

22

45

14

103

6.8

CA 60E-60 B-CA 60E-60

G /2

G /2

18

256

63

CA 80-60/A

G 3/4

G 3/4

23

306

71

90

134 182 106

90

134 112

22

55

17

122

10

9.5

CA 90-60/A

G1

G1

28

318

71

112 142 182 106

90

134 112

22

63

21

128

10

10,8

l2

l3

DN2
DN1

h2
h4
h3
g
4.93.228

s
w

DN1

h1

m2

n2

m1

n1

mm

DN2

TYPE

ISO 228

h1

h2

h3

h4

m1

m2

n1

n2

l2

l3

kg

B-CA 80-60/A

G 3/4

G 3/4

23

307

71

90

134

182 106

90

134

112

22

55

17

122

10

10

B-CA 90-60/A

G1

G1

28

318

71

112

142

182 106

90

134

112

22

63

21

128

10

13.1

146

18

CA

60 Hz

Self-Priming Liquid Ring Pumps

Characteristic curves n = 3450 rpm


0 U.S. g.p.m.

0 Imp.g.p.m.

2
1

0 U.S. g.p.m.

40

Imp.g.p.m. 2

10

50
120

CA 60E

H
m
30

140

m
40

100

59.85

160

CA 80/A
79.6

ft

ft
80
20

120
100

30

60

80
40
10

20

60

20
40
0

0
0
0.32

Q m3/h 0.2

0.4

0.6

10

0.8

0.38
P
HP
0.3

0.16

0.22

1.5

2.5

1.0

0.42

0.28
P
0.24
kW
0.20

Q m3/h 0.5

1.2
0.8
P
0.6
kW
0.4

0.26

1.0
P
HP
0.6
0.4

0.2

12

12

NPSH
8
m

NPSH
8
m

32
NPSH
ft
16

32
NPSH
ft
16

8
0
0

Q m3/h 0.2

0 U.S. g.p.m.

0.4

0.6

0 Imp.g.p.m. 2

0.8

10

72.630

8
0

12
10

70

H
200

CA 90/A

60
m

ft

50

89.6

150

40

100

30

20
50
10
0
1.3

Q m3/h

3
1.4
P
HP
1.2

1
P
kW

1
0.8

0.5
12
NPSH
8
m

30
NPSH
20
ft
10

4
0
0

Q m3/h

72.632

0
3

147

Q m3/h 0.5

1.5

72.631

0
2.5

21

NGL

60 Hz

Self-Priming Jet Pumps


Construction
Close-coupled self-priming shallow-well jet pump with built-in
ejector.

Applications
For drawing water out of a well.
For lifting water containing air or other gases.
For increasing water pressure from flooded suction applications.
As pressure boosting pump for central water systems with
low pressure (follow local specifications if increasing
network pressure).
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature: 0 C to +35 C.
Ambient temperature up to +40 C.
Suction lift up to 9 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Materials
Component
Pump casing
Casing cover
Impeller
Wear ring impeller-diffuser
Diffuser
Ejector
Shaft
Mechanical seal

Material
Cast iron GJL 200 EN 1561
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Brass P-Cu Zn 40 Pb 2 UNI 5705
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
Chrome steel 1.4104 EN 10088 (AISI 430)
Carbon - Ceramic - NBR

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
NGL:
three-phase 220/380 V.
NGLM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

Characteristic curve n 3450 rpm


60

Imp. g.p.m.

10

15

50
150

H
m
40

ft
100

30

NGL 4-60
20
NGL 2-60

NGL 3-60
50

10

m3/h
0
Q l/min
10
0

2
20

30

40

3
50

4
60

5
70

80
72.1072.1

149

22

NGL

60 Hz

Self-Priming Jet Pumps

Technical data n 3450 rpm


220V 380V

3~

220V

1~

IA/IN

NGL 2-60

3,5

4,8

NGLM 2-60

NGL 3-60/A

3,3

1,9

4,3

NGLM 3-60/A

4,2

NGL 4-60/A

2,4

P1 Max. power input.

4,8

IA/IN

4,1

3,3

6,2

3,2

P2 Rated motor power output.

Characteristic Curves
60

NGLM 4-60/A

P1

0 Imp. g.p.m. 5

P2

m3/h
Q
HP
l/min

kW

kW

0,8

0,45 0,6

0,95 0,55 0,75


1,1

0,75

H
m

0,3

2,4

4,5

16,6

33,3

40

50

66,6

75

83,3

51

45

35

24,5

21

53

48

39,5

31

28

22

42,5

40

36

31

29

26

22

20

18

Tolerances according to ISO 9906, annex A.

IA/IN = D.O.L. starting current / Rated current

for different suction lifts Hs

10

15

60

50

0 Imp. g.p.m. 5

10

15

50
150

150

40

NG

40

9
ft

4-

60

ft

8
8

30

7
6

7
6

30

7
6

3
3

100

5
4

4
20

HS = 9m

100

NGL 3-60

1
1 NGL 2-60

20

3
2
1

50
10

20

m3/h 1
0
0 Q l/min 20

2
40

10

5
80

60

0 m3/h 1
0 Q l/min 20

2
40

72.1072.1

60 Hz (n 3450 1/min), H2O, T = 20C, Pa = 1000 hPa (mbar)

Check valve

60
2-

3-

9
Hs
8
m
7

72.1072.3

30
ft
25

20

Hs
G 1 DN 25
(i 28 mm)

60
460

10

0,5 m

5
15
4
10

3
2

5
1

t min

5
80

6
100
72.1072.1

Self-priming capability

0,5 m

4
60

50

150

Hs (m) Suction lift


t (min) Self-priming time

NGL

60 Hz

Self-Priming Jet Pumps

Dimensions and weights

NGL 2,3,4
f
115

h3

116

161

161

ISO 228

4.93.367

33
95
210

10

G1

G1 ISO 228

30

112
146

TYPE

Dimensions
mm

Net weight
kg

NGL NGLM

h3

NGL 2-60

362

176

NGL 3-60/A

391

192 112

11,7 12,6

NGL 4-60/A

391

192 112

12,6 13,6

102 10,5 10,5

22

151

NGL

60 Hz

Self-Priming Jet Pumps

Features

3.93.122

* Patented

A different jet pump with new features


Not just another jet pump.
An exclusive diffuser design with flow control device* provides for compact construction, fast self-priming capability and low noise.

Reliable
With new design features the NGL is more robust and forgiving when temporary abnormal
operating conditions may exist.

Compact
The NGL is smaller than conventional pumps of a similar type, allowing for installation in
restricted spaces and providing for easier retrofit applications.

Safe
Fast air evacuation reduces the risk of air-pockets developing at the mechanical seal
preventing the danger of seal failure due to a lack of flushing and cooling.

Better self-priming
The NGL are capable of lifting water from depths of 9 m in less than 3 minutes, offers new
possibilities on suction lift applications and provides better trouble free service on normal
shallow-well suction lift duties, also with a long suction pipe above the water level.

Low noise
The new diffuser and flow control device* guide the fluid from the impeller into the central
part of the pump casing, reducing turbulence and velocity, with effective use of the
surrounding liquid in dampening the noise of flow.

152

NGX

60 Hz

Self-Priming Jet Pumps


Construction
Close-coupled self-priming shallow-well jet pump with built-in
ejector.
A high-quality pump for domestic water supply. Designed with
environmental considerations, featuring a stainless steel
casing, brass alloy impeller with minimal use of plastic materials.

Applications
For drawing water out of a well.
For lifting water containing air or other gases.
For increasing water pressure from flooded suction applications.
As pressure boosting pump for central water systems with low
pressure (follow local specifications if increasing network pressure).
For clean liquids or slightly dirty surface water.
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature: 0 C to +35 C.
Ambient temperature up to +40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Materials
Component
Pump casing
Casing cover
Impeller
Wear ring
impeller-diffuser
Diffuser
Ejector
Shaft

Material
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Brass P-Cu Zn 40 Pb 2 UNI 5705
Cr-Ni steel 1.4301 EN 10088
(AISI 304)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
Chrome steel 1.4104 EN 10088 (AISI 430)
Cr-Ni steel 1.4305 EN 10088 (AISI 303) for NGX 5,6
Carbon - Ceramic - NBR

Mechanical seal

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
NGX:
three-phase 220/380 V.
NGXM: single-phase 220 V, with thermal protector.
Capacitor inside the terminal box.

23

Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

Characteristic curve n 3450 rpm


0

Imp. g.p.m.

10

15

20

25

30
200

60

50

150

m
40
ft
NGX 5/16-60
100

30

NGX 6/18-60
NGX 5/18-60

NGX 6/22-60

NGX 4-60
NGX 3-60

20

NGX 5/22-60

NGX 2-60

50
10

0 m3/h
0 Q l/min 10

2
20

30

40

3
50

4
60

5
80

70

90

6
100

7
110

8
120

130

140

9
150
72.1072-60

153

NGX

60 Hz

Self-Priming Jet Pumps

Technical data n 3450 rpm


220V 380V

3~

220V

1~
IA/IN

NGX 2-60

3,5

NGX 3-60/A

3,3

1,9

4,8 NGXM 2-60


4,3 NGXM 3-60/A

NGX 4-60/A

4,2

2,4

4,8 NGXM 4-60/A

6,2

220V 380V

3~

4,1

IA/IN

0,8 0,45 0,6


H
m

3,3 0,95 0,55 0,75


3,2

220V

1~

m3/h
Q
IA/IN kW kW HP l/min
P2

P1

0,3

16,6 33,3 40

51

45

35 24,5 21

53

48 39,5 31

42,5 40

1,1 0,75 1

22
22

20

18

2,4

4,5

8,3 16,6 33,3 40

63

1,7 1,1 1,5

NGX 5/18-60 5,7

3,3

5,3 NGXM 5/18-60 8,5

1,7 1,1 1,5

NGX 5/22-60 5,7

3,3

5,3 NGXM 5/22-60 8,5

1,7 1,1 1,5

NGX 6/18-60

5,2

NGXM 6/18-60 10,6 3,3 2,1 1,5

59,5 56,5 53,5 48

NGX 6/22-60

5,2

NGXM 6/22-60 10,6 3,3 2,1 1,5

48,5 47,2 46

60

50

HS = 9m

150

7
6

7
6

ft

NGX 5/16-60

8
30

40

20

m3 /h 1
0
0 Q l/min 20

100

NG
X4

4
60

ft

5
7

3
5

X6

3
4

2
40

100

NG 9
X5
/22

30

G 11/4 DN 32
(i 36 mm)
NGX 5,6

18
-6
0
6/
2
5/ 2-6
16 0
3- -6
6 0
5/ 0
2
4- 2-6
60 0

6
100

10

0 m3 /h
0 Q l/min

60

30

15
4

t min

154

3 2
1

50

6
1

20

100
4

7
2

25

NGX 2-60
NGX 3-60
NGX 4-60
NGX 5/16-60
NGX 5/18-60
NGX 5/22-60
NGX 6/18-60
NGX 6/22-60

ft

20

80

2-

6/

18

5/

ft
7

HS = 9m

30

50

4
60

-6

G 1 DN 25
(i 28 mm)

25

150

72.1072.1

9
Hs
8
m
7

20

-60

10

Hs

27 26,3

/22

10
0 m3/h 1
0 Q l/min 20

4
5

80

NG

60 Hz (n 3450 1/min), H2O, T = 20C, Pa = 1000 hPa (mbar)

Check valve

8,4

200

Self-priming capability

72.1072.3

29

33 34,3 30

15

-60 8

4
6

20

H
40

-60

1 NGX 2-60

0,5 m

60

72.1072.1

0,5 m

6,5

50
150

40

Tolerances according to ISO 9906, annex A.

0 Imp. g.p.m. 10

20

30

42 40,3 37,5 36 34,5

HS = 9m

15

50
10

5,5

46 43,5 39 36,7 34,5 32,5 30,3

43

200

NG
X6
/18
-60
NG
X5
/18
-60

NGX 3-60

8,4

34 32,3 29,5 28,2 26,7 25,5 24,5 23,5 22,7 21 20,5

35

41 39,5 38

10

50 66,6 75 83,3 91,6 100 108 116 133 140

IA/IN = D.O.L. starting current / Rated current

40

53 49,8 46,8 41,7 39,7 37 32,7 30,5 28 26,2 24,7


H
m

0 Imp. g.p.m. 5

15
200

6,5

for different suction lifts Hs

10

60

50

53 44,5 42 38,7 33,3 30,8

5,3 NGXM 5/16-60 8,5

0 Imp. g.p.m. 5

5,5

83,3 91,6 100 108 116 133 140

26

3,3

Characteristic Curves

29

0,5

P2 Rated motor power output.

4,5

28

58

31

m3/h
Q
IA/IN kW kW HP l/min
P2

P1

50 66,6 75

36

NGX 5/16-60 5,7

P1 Max. power input.

2,4

10

Hs (m) Suction lift


t (min) Self-priming time

3
50

6
100

9
150
72.1072.1

NGX

60 Hz

Self-Priming Jet Pumps

Dimensions and weights

NGX 2,3,4
f
115
G1

161

177
h3

116

G1

ISO 228

ISO 228

4.93.281

95
210

TYPE

30

9
112
146

10

33
8
w

Dimensions
mm

Net weight
kg

NGX NGXM

h3

NGX 2-60

362

176

102

7,5

7,5

NGX 3-60/A

391

192 112

8,7

9,6

NGX 4-60/A

391

192 112

9,6 10,6

23
NGX 5-6
488.5
140
G1

213.5

37.5
253

9.5

11

113

9.5

33
155
185

157.5

Net weight
kg

TYPE

NGX

NGXM

NGX 5...-60

15,2

16,7

NGX 6...-60

17,8

18,2

155

240

220

152

ISO 228

G1 1/4

ISO 228

NGX

60 Hz

Self-Priming Jet Pumps

Features

3.93.122

* Patented

A different jet pump with new features


Not just another jet pump.
An exclusive diffuser design with flow control device* provides for
compact construction, fast self-priming capability and low noise.

Reliable
With new design features the NGX is more robust and forgiving when
temporary abnormal operating conditions may exist.

Compact
The NGX is smaller than conventional pumps of a similar type,
allowing for installation in restricted spaces and providing for easier
retrofit applications.

Safe
Fast air evacuation reduces the risk of air-pockets developing at
the mechanical seal preventing the danger of seal failure due to a
lack of flushing and cooling.

Low noise
The new diffuser and flow control device* guide the fluid from the
impeller into the central part of the pump casing, reducing turbulence and velocity, with effective use of the surrounding liquid in
dampening the noise of flow.

156

NG

60 Hz

Self-Priming Jet Pumps


Construction
Close-coupled self-priming shallow well jet pumps with
built-in ejector.
The pumps in bronze are supplied fully painted.

Applications
For drawing water out of a well.
As pressure boosting pump for central water systems with
low pressure (follow local specifications if increasing network
pressure).
For clean liquids or slightly dirty surface water.
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature up to 40 C.
Ambient temperature up to 40 C.
Maximum permissible working pressure up to 10 bar.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
NG: three-phase 220/380 V.
NGM: single-phase 220 V, with thermal protector up to 1.1 kW.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

Materials
Components
Pump casing
Cover with lantern bracket
Diffuser plate
Impeller
Shaft

Diffuser - Ejector
Mechanical seal

NG

B-NG

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Brass P- Cu Zn 40 Pb 2 UNI 5705


Chrome steel
AISI 430 for NG 3-4
Cr-Ni-Mo steel
Chrome-nickel steel
AISI 316
AISI 303 for NG 5-6-7
PPO-GF20 (Noryl)
Carbon - Ceramic - NBR

Special features on request


- Other voltages.
- Protection IP 55.
- Special mechanical seal

Coverage chart n = 3450 rpm


0 U.S. g.p.m. 5

10

0 Imp. g.p.m. 5

15

0 U.S. g.p.m. 10

20

10

20

0 Imp. g.p.m. 10

15

30

40

20

30

65

60

5/16

NG 3
NG 4

ft

100

20

0
0

3
/h 1
Qm
l/min
20

2
40

0 U.S. g.p.m. 10

30

50
150
ft

100

30

0
0

4
40

80

8
120

20

0 Imp. g.p.m. 10
100

30

30

50
10
160

40

20

30

7/16

NG 6

3~

200

300

150

60

1~

/h
Qm
l/min

0 U.S. g.p.m. 10

6/18
60

40

20

5/22

15

15
80

60

20

0 Imp. g.p.m. 10

NG 5

5/18
150

40

200

NG 7

7/18

ft

ft

7/22

200

40

6/22

100

1
20

0
0

/h 2
Qm
l/min

4
40

6
80

8
120

100
10
160

20

0
0

/h
Qm
l/min

4
40

6
80

8
120

10
160
72.837

157

24

NG

60 Hz

Self-Priming Jet Pumps

Performance for suction lift Hs = 1 m


3~

1~

220V 380V

3,6

2,1

NG 3-60/A
B-NG 3-60/A
NG 4-60/A
B-NG 4-60/A

4,5

B-NG 5/16E-60

5,7

n=

P2

220V

IA/IN

3450 rpm
m3/h 0,25 0,5

1,5

2,5

3,5

4,5

5,5

6,5

IA/IN kW

5,2

3,1 0,55 0,75

49

45

35

32

27

2,6

NGM 3-60/A
3,7 B-NGM 3-60/A
NGM 4-60/A
4,5 B-NGM 4-60/A

6,9

3,1 0,75

42

3,3

5,3 B- NGM 5/16E-60

8,5

1,1

40

41 37,5 35

32

30

1,5

58

54

50

46 42,5 40 37,5 36

27

24

5,7

3,3

5,3 B- NGM 5/18E-60

8,5

1,1

1,5

49

47

44 41,5 39 37,5 35

B-NG 5/22E-60

5,7

3,3

5,3 B- NGM 5/22E-60

8,5

1,1

1,5

37

36

35

34

33 31,5 30

29

28 26,5 25,5 24

B-NG 6/18E-60

5,2

1,5

60

58

56

53

50

48

45

43

41

39

36

1,5

54

51

49

46

44

41

39

38

35

34

32

1,5

50

48

47

45

44 42,5 41

40

39

37

36

1,5

44 42,5 41

40

39 37,5 36

35

B- NGM 6/18E-60 10,6 3,8


B-NG 6/22E-60

5,2

6
B- NGM 6/22E-60 10,6 3,8

H
m

33 31,5 30

B-NG 7/16E-60 10,7 6,2

5,9

2,2

82

77

72

67

62 57,5 54

B-NG 7/18E-60 10,7 6,2

5,9

2,2

71

68

65

63

60

57

B-NG 7/22E-60 10,7 6,2

5,9

2,2

57

56

55

54

52

51 49,5 48

IA/IN

9,5

29
23 20,5 18

17

35

33

31

28

27

34 32,5 31,5 30

29

27

25

24

41

38

35

33

55 52,5 51

49

47

45

47

45

44

42

Tolerances according to ISO 9906, annex A.

B-NG, B-NGM = Bronze construction.

= D.O.L. starting current / Rated current

22

B-NG 5/18E-60

HP l/min 4,1 8,3 16,6 25 33,3 41,6 50 58,3 66,6 75 83,3 91,6 100 108 116 133 150 158

P2 Rated motor power output.

Installation examples
Positive suction head operation

Suction lift operation

1m

Check valve.

3.93.100.1

4.93.100

Check valve.

Dimensions and weights


f
a1
DN2

h1

h3

DN1

h2

a2

4.93.104

m2
m1
w

DN1

m3

b
n2
n1

kg

DN2

TYPE
ISO 228

a1

a2

h1

h2

h3

m1

m2

m3

n1

n2

NG

B-NG

NG 3-60/A
NG 4-60/A

B-NG 3-60/A
B-NG 4-60/A

G1

G1

127

430

150

43

207

60

52

185

155

35

9,5

100

11

18,4
19,2

20,8
21,5

NG 5E-60
NG 6E-60
NG 7E-60

B-NG 5E-60
B-NG 6E-60
B-NG 7E-60

G 11/2

G1

160

10

560

165

57

197

60

50

10

215

175

40

11,5

115

11

29,2
30,8
31,3

31,2
32,8
33,3

158

NG

60 Hz

Self-Priming Jet Pumps

Characteristic curves n = 3450 rpm


0 Imp.g.p.m. 2

0 Imp.g.p.m.

10

10

15

50

60

NG 3/A

H
m

NG 4/A

H
m

ft

113

50

160

190

113

140

40

150

ft
120

40
100

30
100

30

80
70

20
0
0.74

Q m3/h

20
0

2
0.85

Q m3/h 1

12
0.7
P
kW

NPSH

0.6
0

Q m3/h

0 Imp.g.p.m.

0.8
P
0.75
kW
0.7

0.65

NPSH
8
m

72.640

10

12

P
NPSH

15

NPSH
8
m

Q m3/h 1
Imp.g.p.m.

10

72.641

15

20

60

70

NG 5/16E

125-120

190

NG 5/18E

125-120

m
60

200

ft

50

ft

150
40

50
150

100

30

40

24
100

30
0
1.4

Q m3/h 1

20
0

4
1.4

P
1.3

NPSH

0 Imp.g.p.m.

10

20

72.642

120

NG 5/22E

100

30

ft
80
20
60

40
10
0

Q m3/h 2

10

1.3
12

P
1.2
kW

NPSH

NPSH

4
1.1
0

Q m3/h 2

72.644

NPSH

m
4

30

119

1.2

40

kW

0
3

12
1.3

4
2

kW

Q m3/h 1

Q m3/h 1

16

16
NPSH
12
m
8

70

0
10

159

Q m3/h 1

72.643

0
6

NG

60 Hz

Self-Priming Jet Pumps

Characteristic curves n = 3450 rpm


0 Imp.g.p.m.

10

20

30

Imp.g.p.m.

10

20

70

60
190

NG 6/22E

H
ft

NG 6/22
134

NG 6/18E

NG 6/18
134

m
50

200

60

ft

150
NGM 6/22
128

40

NGM 6/18
128

50

150
100

30

40

70

20
0

Q m3/h 2

100

30

10

Q m3/h

2.0

2.0
NG 6/22

1.9
1.8
P
kW

1.6

NGM 6/22

NPSH

10

1.9

8
NPSH
6
m
4

P
kW
1.7

1.5
0

Q m /h 2

0 Imp.g.p.m.
110

10

72.646

P
NPSH

1.5

10

Q m /h
3

0 Imp.g.p.m.

15

10

72.645

20

80
350

NG 7/18E

NG 7/16E

100

8
NPSH
6
m
4

NGM 6/18

1.6

2
3

10

NG 6/18
P

143

300

250

143

m
70

ft

ft

80
250

200

60

70
200

60

50

50

150
150
40

40
0
2.5

Q m3/h 1

0
2.5

kW

10
8
6
4
2

NPSH

2.1
0

Q m3/h 1

0 Imp.g.p.m.

10

20

72.647

30

200

143

H
ft

50
150
40

100

30
0
2.5

Q m3/h 2

10

10

2.4
P

2.3
P
2.2
kW
2.1

8
NPSH
6
m
4

NPSH

2.0
0

Q m3/h 2

72.649

NPSH
m

10
8
6
4
2

NPSH

2.1

NG 7/22E

60

2.4
P
2.3
kW
2.2

NPSH
m

P
2.3

Q m3/h

10

160

Q m3/h

72.648

MXA 60 Hz

Multi-Stage Self-Priming Pumps

Construction
Horizontal multi-stage, self-priming, close coupled
pump.
Single-piece barrel casing in chrome-nickel stainless
steel, with front suction port above pumps axis and
radial delivery at top.
Stages in Noryl.

Applications
For water supply.
For domestic use, for garden use and irrigation.

Operating conditions
Liquid temperature: 0 C to +35 C.
Ambient temperature up to +40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Materials
Component
Pump casing
Casing cover

Material
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Pump Shaft

Chrome steel 1.4104 EN 10088 (AISI 430)


Cr-Ni steel 1.4305 EN 10088 (AISI 303) for MXAM 403 MXA 404
Cr-Ni steel 1.4305 EN 10088 (AISI 303)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
Carbon - Ceramic - NBR

Plug
Suction casing
Stage casing
Impeller
Mechanical seal

Motor
2-pole induction motor, 60 Hz (n = 3450 1/min).
MXA:
three-phase 220/380 V 10%.
MXAM: single-phase 220 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

25

Characteristic curves n 3450 rpm


70

MXA-60Hz

60

204

50
H
m
40

H2O, T = 20C,
Pa = 1000 hPa (mbar)
60 Hz (n = 3450 1/min)

404

203

Self-priming
capability

200

150

Hs

ft
403

h (mm)
202
100
100
100
200
300

203
100
200
300
300
450

8
MXA-60Hz 204
m

100

202

30

Hs
(m)

2
4
6
7
8

402
100
100
100
200
-

203

403
500
500
500
500
-

20

404
500
500
500
500
202

404

25

403

0,5 m

402

204
100
200
300
450
450

ft

402

20

50
10

72.1158

15

Check valve

0
0

m3/h
Q l/min

3
50

6
100

9
150

0
10

Hs
G 1 DN 25
(i 28 mm)

10

60
NPSH

30

8
NPSH
6
m
4

20

10

0
9 72.1157 10

50

Q m3/h

10

2
G 11/4 DN 32
(i 36 mm)

MXAM 403-60
MXA 404-60

Hs (m) Suction lift

161

t min 1

t (min) Self-priming time

MXA 60 Hz

Multi-Stage Self-Priming Pumps

Performance n 3450 rpm


220 V 380 V

3~

A
3,1
MXA 202-60
MXA 203-60/A 4,2
MXA 204-60/A 4,2

A
1,8
2,4
2,4

IA/IN
4,8 MXAM 202-60
4,8 MXAM 203-60/A
4,8 MXAM 204-60/A

220 V 380 V

3~
MXA 402-60/A
MXA 403-60/A
MXA 404-60

A
4,2
5,4
8

A
2,4
3,1
4,6

220 V

1~

1~

A
4,1
6,2
6,2

P2
IA/IN
2,7
3,2
3,2

kW
0,45
0,75
0,75

220 V

m3/h

l/min

HP
0,6
1
1

6,3
105

19
30
38

14
23
29

15
19

14

8,4

10

100

116

133

140

150

166

33,5 31,5 27,5 25 21,5


37
32
46
41
m 50
65,5 61,5 55 50,5 45,5

18
27
40

14
20
33

15
30

24,5 14,5

16,6 33,3

50

30
45
60

27
41
53

23
35,5
47

m3/h

l/min

66,6 83,3 100

Q
HP
1
1,5
2

32
49
65

P2

IA/IN kW
IA/IN
A
3,2 0,75
4,8 MXAM 402-60/A 6,2
3
1,1
4,2 MXAM 403-60
8,5
6,2 MXAM 404-60
10,6 3,8 1,5

P2 Rated motor power output.

Test results with clean cold water, without gas content.


+ 0,5 m security margin on NPSH-value is necessary.

33,3 66,6 83,3

Tolerances according to ISO 9906, annex A.


For capacities over 4 m3/h use a suction pipe G 1 1/4 (DN 32).

Dimensions and weights


488.5

140

115

161

213.5

G1

G1

ISO 228

4.93.281

210

37.5

30

113

112
w

146

mm
TYPE
MXA 202-60 - MXAM 202-60
MXA 203-60/A - MXAM 203-60/A
MXA 204-60/A - MXAM 204-60/A
MXA 402-60/A - MXAM 402-60/A
MXA 403-60/A

f
362
391
391
391
391

h3
176
192
192
192
192

w
102
112
112
112
112

9.5

253

Net weight
kg
MXA MXAM
7,3
7,3
9,6
10,6
9,7
10,7
9,5
10,5
11,1

9.5

11

95

10

33

MXAM 403-60
MXA 404-60 - MXAM 404-60

155
185

157.5

TYPE

33

Net weight
kg
MXA
MXAM
17,2

16,3
17,6

Features
Extra safety
against running dry, with the suction port
above pump axis and with the self-priming
construction.
Robust
Single-piece barrel casing.
Compact
Single-piece lantern bracket and base.
Low noise
with the water-filled shroud around the stages.
3.93.124

162

240

220

152

G1 1/4

ISO 228

177
h3

116

G1

ISO 228

ISO 228

I, IR

60 Hz

Gear Pumps
Construction
Close-coupled gear pumps (rotary pumps).
Pump casing with suction and delivery connections with the
same diameter and on the same axis (in-line execution).

Applications
For fuel oil and liquids with lubricating properties.

Operating conditions
Kinematic viscosity from 30 mm2/s (4 E) to 120 mm2/s (15E).
Liquid temperature up to 90 C.
Ambient temperature up to 40 C.
Total suction lift up to 4 m.
Continuous duty.

Motor
- 4-pole induction motor, 60 Hz (n = 1750 rpm).
I, IR, IRR: three-phase 220/380 V.
IM : single-phase 220 V.
Insulation class F.
Protection IP 54.
Execution according to IEC 60034.

Materials
Components

Materials

Pump casing
Gears
Shafts
Radial shaft seal ring

Cast iron GJL 200 EN 1561


Steel 18 Ni Cr Mo 5 UNI 8550
Steel 18 Ni Cr Mo 5 UNI 8550
FPM

Special features on request


- Other voltages.
- Protection IP 55.
- Higher liquid or ambient temperatures.

26

Performances n = 1750 rpm


3~

220V 380V

1~

220V P1

P2

m /h

0.72

l/min

12

Q
I
25/4-60/A
IR
25/4-60/A
IRR 25/4E-60

P1 Max. power input.

1,7
2,4
4,4

1
1,4
2,3

IM 25/4-60/A

kW

kW

HP

rpm

2,5

0,48

0,25
0,37
0,75

0,34
0,5
1

1750
1750
1750

p
bar

2
2.5
5

p Differential pressure.

P2 Rated motor power output.

163

I, IR

60 Hz

Gear Pumps

Dimensions and weights

319

140

35

G1

G1

ISO 228

120
ISO 228

I 25/4-60/A
IM 25/4-60/A
IR 25/4-60/A

182
88
10

TYPE

kg

10

25/4-60/A

IM 25/4-60/A

11.7

IR 25/4-60/A

11.6

4.93.224

10

22

90

112

106

134

368

120

G1
10

G1

187

ISO 228

IRR 25/4E-60

ISO 228

160

35

97

107.5

TYPE
IRR 25/4E-60

4.93.065

9.5
125

30

100

125

117

155

164

kg
15.8

B-VT

60 Hz

Peripheral Immersion Pump


Construction
Vertical close-coupled peripheral (regenerative) pumps with
submerged turbine impeller, seal-less, reversible.
Port dimension to EN 12157.
Submerged deph 170 mm.

Applications
For clean liquids without abrasives, without suspended
solids, non-explosive, non-aggressive for the pump materials.
For the reduced dimensions, these pumps are very well
suited for use with temperature controllers, chillers, and
air-conditioning machines and systems.

Operating conditions
Liquid temperature:

- with water up to 90 C.
- oil up to 150 C.
Max. kinematic viscosity: 20 mm2/s at 50 C (2,9 E).
Ambient temperature: up to 40 C.
Max. depression 0,9 bar.
Continuous duty.

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
B-VT: three-phase 220/380 V.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.

Materials
Components

Materials

Pump casing
Casing cover

Bronze G-Cu Sn 10 UNI 7013


Bronze G-Cu Sn 10 UNI 7013

Impeller
Shaft
Bearing sleeve
Bearing in the casing
Screws

Brass P- Cu Zn Pb 2 UNI 5705


Chrome steel 1.4104 EN 10088 (AISI 430)
Corrosion-resistant Cr-Mo steel
Polymer
Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Special features on request


- Terminal box arrangement 2-3-4 in accordance with EN 12157.
- Oil temperature up to 180 C.
- Other voltages.
- Protection IP 55.

Characteristic Curves with water at 20 C ( = 1 mm2/s)


0 U.S. g.p.m. 2
0 Imp. g.p.m.

10

12

3450 rpm

14

10

50

160

B-VT

140

40
120

B-VT 65/170-60
30

100

H
ft

B-VT 60/170-60

20

60
40

10
20
0

0
0

m 3/h
Q l/min

1
10

2
20

30

3
50

40

72.1159-60Hz

165

27

B-VT

60 Hz

Peripheral Immersion Pump

Performance n = 3450 rpm


3~

230V

B-VT 60/170-60
B-VT 65/170-60

400V

kW

HP

m3/h
Q
l/min

2
3,1

1,2
1,8

0,33
0,45

0,45
0,6

H
m

P2 Rated motor power output.

P2

0,3

0,48

41,5
47

36
41

33
38

0,6

0,75 0,96

10

12,5

1,2

1,5

1,89

2,4

20

25

31,5

40

50

19,5 15
27 23

8,5
17,5

3
10

16

30,5 27,5 23,5


36
34 30,5

H Pump outlet head

Dimensions and weights

Terminal box arrangement (view from motor side)


EN 12157

B-VT 60/170-60: kg 8,2


B-VT 65/170-60: kg 8,4

15

1
Standard

7
95

70

2, 3, 4

25

20

218

G 3/4 ISO 228

On request

MAX.
99.8
170

130

40

MIN.

166

VAL, SC

60 Hz

Vertical Submerged Pumps


Construction
Vertical column sump pumps, with motor in dry installation
and with pump body submerged in the liquid handled
(without suction line or foot valve).
Impeller

- VAL: free-flow impeller


(vortex or recessed impeller).
- SC: open impeller.

Connection -VAL 30, SC 30, SC 50: threaded port ISO 228 (BS 2779).
- VAL 65: flange with plain face oval threaded
counter-flange UNI 2245, PN 2.5.

Applications
- For draining a basin or a sump with domestic or industrial
sewage.
- For slightly dirty waste water, for liquids which are nonaggessive for the pump materials.

Operating conditions
Liquid temperature up to 40 C.
Ambient temperature up to 40 C.
Continuous duty.
Maximum size of solids: VAL 30 = 25 mm; VAL 65 = 50 mm;
SC 30 = 3 mm; SC 50 = 6 mm.

Motor
Materials
Components
Pump casing
Lower bearing housing*
Impeller

Shaft
Bearing bush
Shaft sleeve

VAL
SC
Cast iron
Cast iron
GJL 200 EN 1561
GJL 200 EN 1561
Brass P-Cu Zn 40 Pb 2 UNI 5705
Brass
for VAL 30
P-Cu Zn 40 Pb 2 UNI 5705
Cast iron GJL 200 EN 1561
for VAL 65
Steel C 40 UNI 7231
Tecnopolymer
Chromate bronze for VAL 65

2-pole induction motor, 60 Hz (n = 3450 rpm).


VAL - SC: three-phase 220/380 V.
VALM - SCM: single-phase 220 V, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with IEC 60034.

Special features on request


- Other voltages.
- Protection IP 55.
- Bronze bearing bush (for liquid up to 100 C).
- Higher liquid or ambient temperatures.

* Not existing for VAL 30.

Coverage chart n = 3450 rpm


U.S. g.p.m.

10
10

20

30

Imp. g.p.m.

20

40
30

40

28

100

50

100

50

12

SC 30-60/A
SC 50-60/A

VAL, SC

10

30

H
m

VAL 30-60/A

VAL 65E-60

ft
20

4
10
2

40

m 3/h 4

Q l/min
50

20

10
100

200

300

30
400

40

500
72.835.C

167

VAL, SC

60 Hz

Vertical Submerged Pumps

Performance n = 3450 rpm


3~

220V

5,2

P2

m3/h

3,5

7,2

4,1 2,5 0,45 0,6

10,7 6,2 5,9

1,5

2,2

SC 30-60/A

2,6 1,5 3,5 SCM 30-60/A

3,4 2,3 0,37 0,5

SC 50-60/A

2,6 1,5 3,5 SCM 50-60/A

4,1 2,5 0,45 0,6

IA/IN

4,5

5,5

6,5

7,5

10

12

14

16

6,5 6,3

5,5 5,2 4,8 4,5

H
m
11 10,5 10 9,4 8,6

20

25

30

3,2 2,2
8,5 8,4 7,9 7,4

6,5 5,9 4,5

8,5 8,4 7,9 7,4

6,5 5,9 4,5

7,2 6,4 5,3 4,5

10,7 10,6 10,5 10,4 10,3 10,2 10 9,8 9,4 8,2 6,6 4,7 2,7

P2 Rated motor power output.

= D.O.L. starting current / Rated current.

H Total head in m.

Tolerances according to ISO 9906, annex A.

Dimensions and weights


VAL 30-60/A
SC 30-60/A
SC 50-60/A

VAL 65E-60
VAL 65-RE-60

h3

h3
CALPEDA

h1
h1

h2

L max
h2
1)

L max
1)

DN
DN
L min

L min

h4

h4
B

A
l

l
4.93.058

4.93.173

1) Float switch (on request)

l1

TYPE
VAL 30/750-60/A
VAL 30/1000-60/A
VAL 65/1000E-60 VAL 65/1500E-60 VAL 65/2000E-60 VAL 65/2500E-60 SC 30/500-60/A
SC 30/750-60/A
SC 30/1000-60/A
SC 30/1250-60/A
SC 50/500-60/A
SC 50/750-60/A
SC 50/1000-60/A
SC 50/1250-60/A

18

A IA/IN kW HP l/min 50 58,3 66,6 75 83,3 91,6 100 108 116 125 133 150 166 200 233 266 300 333 416 500

2,6 1,5 3,5 VALM 30-60/A

VAL 65E-60
VAL 65-RE-60

1~

A IA/IN

A
VAL 30-60/A

220V 380V

G 1 /4
1

VAL 65/1000-RE-60
VAL 65/1500-RE-60
VAL 65/2000-RE-60
VAL 65/2500-RE-60

mm

DN
ISO 228

G 2 1/2

G 1 1/4

G2

l1

h1
1025
1275
1245
1745
2245
2745
765
1015
1265
1515
780
1030
1280
1530

h2
825
1075
1010
1510
2010
2510
565
815
1065
1315
580
830
1080
1330

h3

h4

l1

L min

200

82

111

120

150

235

140

117

140

250

200

105

111

100

200

200

120

111

120

215

168

L max
750
1000
950
1450
1950
2450
455
705
955
1205
470
720
970
1220

180

235

175

283

132

192

173

243

kg
15,8
17,4
40
48
56
64
14,9
16,7
18,6
20,5
17,3
19,3
21,3
23,6

VAL, SC

60 Hz

Vertical Submerged Pumps

Characteristic curves n = 3450 rpm


0 U.S. g.p.m. 10
0 Imp.g.p.m.

20
10

30
20

40
30

U.S. g.p.m.

40

0 Imp. g.p.m.

10

60
40

80

120

100

60

80

100

12
30

VAL 30

67

ft

VAL 65
VAL 65-R

108 sp.11

10

30

m
20

ft

20

4
10

10
0

0
0

0.5

Q m3/h 2

10

0
2.8
0.6

0.4

0.4
P
HP
0.2

Q m3/h 2

0 U.S. g.p.m. 10
0 Imp.g.p.m.

20
10

30
20

72.655

10

3.6
3.2
P
2.4

1.6

HP

1.2

0.1

30

20

2.4
P
kW

0.5

0.3
P
0.2
kW
0.1

10

Q m3/h

1.6
1.2

0.8

10

Q m3/h

0 U.S. g.p.m. 20

40

0 Imp.g.p.m.

30

16

72.656

20

40
20

60
40

30

80
60

16
50

SC 30

SC 50

85

12

40

40

12

67

ft

ft
30

20

20

4
10

0
0

0.5

Q m3/h 2

10

0
0

0.6

Q m3/h 4

12

20

16

0.8

0.6
0.4
P
0.3
kW
0.2

0.7
P
HP
0.5

0.5
P
0.4
kW
0.3

0.5
P
HP
0.3

0.4

0.2
0.1

0.3

0.2
0

Q m3/h 2

72.657

10

169

Q m3/h 4

12

16

72.658

20

28

GM 10

60 Hz

Submersible Drainage Pump


Construction
Submersible drainage pump constructed with composite
polymers developed especially for this product.
These new rustproof materials are resistant to corrosion,
indeformable at maximum temperature differentials in the
pump and motor and resistant to internal and external strain.
Shaft of chrome steel AISI 430. Three lip seals in NBR.
Minimum dimension and high levels of performance, for use
in many different applications, for flow rates up to 200
liters/min.
With float switch for automatic start/stop.

Applications
For clean or slightly dirty water.
For draining flooded rooms or tanks.
Extraction of water from ponds, flowing water or pits for
collection of rain water.
For irrigation purposes.
For use outdoor, the power supply cable shall have a length
not less than 10 m.

Operating conditions
Maximum liquid temperature for prolonged use: 30 C
(with immersed motor).
Immersion depth: 5 m max (with suitable cable length).
Not suitable for continuous duty for prolonged time.

Motor
2-pole, single-phase, 220 V, 60 Hz induction motor.
With thermal protector.
Capacitor inserted in the housing incorporated in the plug.
Cable: with plug, length 5 m, 4 G 0.75 mm2.
Insulation class B.
Protection IP 68.
Triple impregnation humidity-proof dry winding.

Special features on request


Other voltages.
Cable H07RN8-F, 4 G 1 mm2, length 10 m.
Control box with on-off switch and capacitor, for pumps
without plug.
Without float switch.
With elbow on discharge port.

Characteristic curve n = 3450 rpm


0 U.S. g.p.m. 10
0 Imp. g.p.m.

20
10

30
20

40
30

29

50
40

ft

GM 10-60

20

4
10

1~

220V Capacitor

P2

m3/h

l/min

50

100 150 200

7,5

6,5

5,2

12

Q
A

IA/IN kW

HP

GM 10-60 2,1 6,3 450 3,1 0,3 0,4


0

0
0

m3 /h
l/min

3
50

6
100

9
150

12
200

0
P2
= Rated motor power output
IA/IN = D.O.L. starting current / Rated current

72.847

171

Hm

3,7

2,2

GM 10

60 Hz

Submersible Drainage Pump

Dimensions and weights


Weight kg 5

Control box (on request)


Type

Capacitor

QM 10
75

6,3 F

Weight

450 V

M20x1,5

0,4 kg

76

4.93.119

40

200

179

212

G 1 1/2

4.93.130

168

M20x1,5

Installation examples

Features
Maximum reliability
A metal support ensures correct alignment between the pump shaft
and the motor also in heavy duty conditions.
A threaded metallic insert in the delivery port allows for secure connection of the delivery pipe or fitting without any risk of damaging
the pump.
A suction strainer prevents solids bigger than 8 mm grain size from
entering the pump.

100

300

Off
Arresto

40

212

On
Avviamento

3.93.004/2

G 1 1/2
ISO 228

179 max
min 350 x 350

Low cost installation


Immersed without suction pipe and valve. No filling operations at
start-up, no suction problems and greater safety against running
dry.
3.93.003

172

GXR, GXV

60 Hz

Submersible Pumps
in stainless steel
Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXR: with open impeller.
GXV: with free-flow (vortex) impeller.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.
Minimum dimension and high levels of performance, for use
in many different applications, head up to 12,7 m and flow
rates up to 220 liters/min.

Applications
GXR: - For clean water containing solids up to 10 mm grain size.
- For draining rooms or or emptying tanks.
- Extraction of water from ponds, streams or pits and
for rainwater collection.
- For irrigation purposes.
GXV: - For clean or slightly dirty water, containing solids up to
25 mm grain size.
- Particularly suitable for liquids with a high solid content.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.

Operating conditions
Liquid temperature up to 50 C.
Maximum immersion depth: 5 m.
Minimum water level with float: GXR = 70 mm, GXV = 130 mm.
Minimum water level manual operation: GXR = 15 mm, GXV = 30 mm.
Continuous duty.

Materials
Component
Pump casing
Strainer
Impeller
Motor jacket
Pump jacket
Handle
Shaft
Mechanical seal
Seal lubrication oil

Material
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Polypropylene
Chrome-nickel steel AISI 303
Ceramic alumina/Carbon/NBR
Oil for food/pharmaceutical machinery

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
GXR, GXV:
three-phase 220 V;
three-phase 380 V;
GXRM, GXVM: single-phase 220 V,
with float switch and thermal protector.
Incorporated capacitor.
Insulation class F.
Protection IP X8 (for continuous immersion)
Double impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60 335-2-41.

Other features on request


- Other voltages. - Other mechanical seal.
- Cable length 10 m. - Vertical magnetic float switch.

Characteristic curves n = 3450 rpm


14

14

GXR

30

GXV
12

12
GX

10

GX

GX

13

-60

11

9-6

10
GX

V2

-60

GXV

0
0

m3 /h
l/min 50

10
100

150

15
200

250
72.1219

25-8

GX

V2

0-6

-60

5-1

0
0

m3 /h
l/min 50

5-6

-60

10
100

150

15
200

250
72.1219.1

173

GXR, GXV

Submersible Pumps
in stainless steel

60 Hz

Performance n = 3450 rpm


220V 380V

3~

220V

1~

P2

IA/IN

IA/IN

GXR 9-60

1,4

0,8

3,8

GXRM 9-60

2,5

2,3

0,25 0,33

GXR 11-60

3,1

1,8

3,8

GXRM 11-60

3,6

2,3

0,37

0,5

GXR 13-60

3,4

3,5

GXRM 13-60

4,9

2,5

0,45

0,6

220V 380V

3~

220V

1~

IA/IN

GXV 25-6-60

1,4

0,8

3,8

GXV 25-8-60

3,1

1,8

3,8

GXV 25-10-60

3,4

3,5

HP

P2
IA/IN

kW

HP

GXVM 25-6-60

2,5

2,3

0,25 0,33

GXVM 25-8-60

3,6

2,3

0,37

0,5

GXVM 25-10-60

4,9

2,5

0,45

0,6

Cable material

Section

l/min

20

8,5

11

10,4

13
m3/h
l/min

Hm

4,5

7,5

10,2

12

13,2

50

75

100

125

150

170

200

220

7,5

6,5

5,5

4,5

3,4

2,3

9,5

8,5

7,3

6,3

5,3

4,4

2,7

1,7

12,2

11

10

8,7

7,8

6,3

5,3

3,5

1,2

4,5

7,5

10,2

12

13,2

20

50

75

100

125

150

170

200

220

5,7

5,2

4,6

3,3

2,6

8,2

7,8

7,3

6,8

6,2

5,5

4,7

9,5

9,2

8,7

8,2

7,5

6,6

5,6

4,8

3,5

1,2

Kinematic viscosity = max 20 mm2/sec.

Power supply cable

Pump
type

m3/h

Hm

Density = 1000 kg/m3.

P2 Rated motor power output.

kW

2,6

Tolerances according to ISO 9906, annex A.

Float switch
Length

Plug

Cable material

Section

CEE 7(VII)

GXRM 9-60
GXVM 25-6-60

H05RN-F

3G0,75 mm2

5m

YES

H07RN-F

3G1 mm2

GXRM 11-60, 13-60


GXVM 25-8-60, 25-10-60

H07RN-F

3G1 mm2

5m

YES

H07RN-F

3G1 mm2

GXR 9-60
GXV 25-6-60

H05RN-F

4G0,75 mm2

5m

NO

NO

GXR 11-60, 13-60


GXV 25-8-60, 25-10-60

H07RN-F

4G1 mm2

5m

NO

NO

H1

10

25

H1

Dimensions and weights

4.93.411

176
56

56

TYPE

ISO 228

G 1 1/4

ISO 228

G 1 1/4

176

4.93.388

Dimensions
mm
H

H1

(1)
kg

TYPE

GXR GXRM

Dimensions
mm
H

H1

(1)
kg
GXV GXVM

GXR 9-60 - GXRM 9-60

265 230

5,2

GXV 25-6-60 - GXVM 25-6-60

302 267

5,1

5,3

GXR 11-60 - GXRM 11-60

300 265

6,2

6,5

GXV 25-8-60 - GXVM 25-8-60

337 302

6,3

6,6

GXR 13-60 - GXRM 13-60

300 265

6,7

7,2

GXV 25-10-60 - GXVM 25-10-60 337 302

6,8

7,3

(1) With cable length: 5 m

(1) With cable length: 5 m

174

GXR, GXV

60 Hz

Submersible Pumps
in stainless steel

Installation examples

G 1 1/4

G 1 1/4

ISO 228

ISO 228

On
On

375
340

Off

Off

130

70
3.93.037/3

3.93.037/3

176

176

min 350 x 350

min 350 x 350

Installation examples with vertical magnetic float switch

30

h
min

h
max

h H
max

h
min

3.93.037/3

3.93.037/3

176

176

min 250 x 250

min 250 x 250

mm

TYPE
H

h
min

h
max

GXRM 9-60 GF

265

100

190

GXRM 11-60 GF

300

135

225

GXRM 13-60 GF

300

135

225

mm

TYPE

175

h
min

h
max

GXVM 25-6-60 GF

302

60

150

GXVM 25-8-60 GF

337

60

185

GXVM 25-10-60 GF

337

60

185

GXR, GXV

60 Hz

Submersible Pumps
in stainless steel

Features
PATENTED

G 1 1/4 vertical, upward delivery port for installation in


small pits, without the need for an elbow on the pump.

Handle in polypropylene.

Easy inspection of the


capacitor area

Shaft in chrome-nickel
stainless steel.
Easy adjustment of the
float switch: to allow the
adjustement of start/stop
pump levels

Motor cooled by the pumped


water passing between the
motor jacket and the external
jacket.

Ceramic stainless steel shaft


sleeve

Oil chamber

GXR
GXV
Suction strainer with a double row of holes, for extra
safety against clogging.
GXV: it allows the passage of solids up to 25 mm.

Suction strainer with a double row of


holes, for extra safety against clogging.
GXR: it allows the passage of solids
up to 10 mm.
Impeller in chrome-nickel stainless steel.

The double shaft seal with oil chamber separates the


motor from the water and provides further protection
against accidental operation when dry.

176

GXV

60 Hz

Submersible Sewage and Drainage Pumps


Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXV: with free-flow (vortex) impeller.
Double shaft seal with interposed oil chamber.

Applications
For clean und dirty water, also containing solids up to 35 mm
grain size.
The GXV free-flow impeller construction is particularly suitable for
liquids with a high solid content or with filamentous particles.
This construction (with smooth surfaces in rolled-stainless steel
and easy access for cleaning) is also suitable for certain uses in
the food industry.

Operating conditions
Liquid temperature up to 35 C.
Minimum immersion depth: 250 mm.
Maximum immersion depth: 5 m.
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
GXV: three-phase 220 V;
three-phase 380 V;
GXVM: single-phase 220 V,
with float switch and thermal protector.
Control box with capacitor.
Cable: H07 RN8-F, 4G1 mm2, length 10 m.
Insulation class F.
Protection IP 68 (for continuous immersion)
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60 335-2-41.

Materials
Component

Material

Pump casing
Casing cover
Impeller
Motor jacket
Jacket cover
Handle

Chrome-nickel steel AISI 304


Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304
Chrome-nickel steel AISI 304

Shaft

Chrome-nickel steel AISI 303

Mechanical seal

Ceramic alumina/Carbon/NBR

Seal lubrication oil

Oil for food/pharmaceutical machinery

Other features on request


- Other voltages.
- Other mechanical seal.
- Cable length 20 m.
- Sleeve and clamp for flexible hose.

Characteristic curves n = 3450 rpm


0

U.S. g.p.m.

Imp. g.p.m.

30

20
20

40
30

50
40

60
50

70

80

60

100

90
70

31

80

10
30

GXV

ft

H
m

GXV 40A-60

20

GXV 40B-60

4
10
2

0
0

m 3/h
l/min

6
100

12
200

18
300

24
400
72.848

177

GXV

60 Hz

Submersible Sewage and Drainage Pumps

Performance n = 3450 rpm


3~

220 V 380 V

1~

GXV 40B-60

3,3

1,9

GXV 40A-60

4,6

2,7

3,9

220 V

IA/IN

P2

Capacitor

GXVM 40B-60

5,5

20

450

GXVM 40A-60

25

450

3,3

IA/IN = D.O.L. starting current / Rated current.

IA/IN kW

HP

m3/h

l/min

50

100

150

15

18

21

200 250

12

300

350

3,2

0,55 0,75

8,1

5,9

3,9

2,9

0,9

9,5

8,6

7,6

6,6

5,5

4,4

P2 Rated motor power output.

1,2

Density = 1000 kg/m3.

Kinematic viscosity = max 20 mm2/sec.

Tolerances according to ISO 9906, annex A.

Dimensions and weights -

Installation

Stationary
installation

Trasportable
installation

On

G 1 1/2
ISO 228

Off
450

TYPE

kg

40B-60
40A-60

380
405

9.9
11.5

GXVM 40C-60
GXVM 40B-60

380
405

11.7
13

250
165

GXV
GXV

3.93.037/3

215
min 550 x 550

3.93.037/3

Features
Control box for single-phase pumps

Pump

Control
box
pump

Capacitor
with
450 Vc

GXVM 40B-60

QM 11

20 F

GXVM 40A-60

QM 12

25 F

Weights kg 0,4

75
Pg 11

76

Low cost installation


Vertical, upward delivery port for
installation in small pits, without
the need for an elbow on the
pump.
Handle for transport and installation (in suspended position or
with flexible hose) by means of a
safety rope for securing and lifting
the pump.

Reliable

200

All parts in contact with the liquid,


inside and outside the pump, are
in chrome-nickel stainless steel.
With corrosion-resistant seal
rings and heavy polychloroprene
sheathed power cable.

Extra safety

Pg 11

The double shaft seal with interposed oil chamber separates the
motor from the water and provides further protection against
accidental operation when dry.

178

4.93.118/1

GXV

GXC

GMC, GMV

Submersible Sewage
and Drainage Pumps

60 Hz

Construction
Close-coupled electric submersible pumps.
GMC: with single-channel impeller.
GMV: with free-flow (vortex) impeller.
Double mechanical seal with interposed oil chamber, to
protect against dry-running.

Applications
For domestic or industrial waste water, dirty water with
solids up to 45 mm grain size for GMC and 50 mm for
GMV, for liquids which are compatible with the pump
materials.

Operating conditions
Liquid temperature up to 35 C.
pH value: 6-11.
Maximum immersion depth: 10 m (with suitable cable length).
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 60 Hz (n = 3450 rpm).
GMC, GMV: three-phase 220 V.
three-phase 380 V.
2 built-in thermal protector to be connected to
a control box.
Cable: 4G1.5 mm2 + 2x0.5 mm2, length 10 m.
GMCM, GMVM: single-phase 220 V, with float switch,
built-in thermal protector and built-in capacitor.
Cable: H07RN8-F, 3G1.5 mm2, length 10 m,
with plug (CEI-UNEL 47166).

Materials
Components
Pump casing
Casing cover
Impeller
Motor housing
Motor cover
Shaft
Mechanical seal: Upper
Lower
Seal lubrication oil

Material
Cast iron GJL 200 EN 1561
Cast iron GJL 200 EN 1561
Cast iron GJL 200 EN 1561
Cast iron GJL 200 EN 1561
Cast iron GJL 200 EN 1561
Chrome steel AISI 430
Carbon, ceramic, NBR
Silicon carbide, silicon carbide, NBR
Oil for food machinery and pharmaceutic use

Insulation class F.
Protection IP X8.
Triple impregnation, humidity-proof winding.
Constructed in accordance with: EN 60 335-2-41.

Characteristic curves n = 3450 rpm


0 U.S. g.p.m.

50

0 Imp.g.p.m.

100
50

150

0 U.S. g.p.m.

200

100

50

0 Imp.g.p.m.

150

100

150

50

100

15

20
60

40

m
50

15

GMC

ft
40

GMV

10

ft
30

10

30

20
5

20
5

10
10
0

0
0

Q m3/h 10

20

30

50

40

0
0

1.6

Q m3/h

10

20

40

30

1.6
2

A
B

N
kW

200

20
300

30
400

500

40
600

700

N
kW

HP

m3/h 10

Q l/min
0

HP

50

0
0
0

800
72.660

m3/h
l/min

10

20
200

300

40

30
400

500

600
72.661

179

32

GMC, GMV

Submersible Sewage
and Drainage Pumps

60 Hz

Performance n = 3450 rpm


3~

GMC 50CE-60
GMC 50-65C-60
GMC 50BE-60
GMC 50-65B-60
GMC 50AE-60
GMC 50-65A-60

3~

GMV 50CE-60
GMV 50-65C-60
GMV 50BE-60
GMV 50-65B-60
GMV 50AE-60
GMV 50-65A-60
IA/IN

220 V 380 V
A

IA/IN

4,1

2,4

3,2

5,6

3,2

3,2

4,6

3,3

GMCM 50CE-60
GMCM 50-65C-60
GMCM 50BE-60
GMCM 50-65B-60

220 V 380 V
A

IA/IN

4,1

2,4

3,2

5,6

3,2

3,2

4,6

3,3

GMVM 50CE-60
GMVM 50-65C-60
GMVM 50BE-60
GMVM 50-65B-60

= D.O.L. starting current / Rated current.

P2

IA/IN

kW

HP

5,4

3,1

0,75

7,5

3,2

1,1

1,5

1,5

220 V

1~

P2 Rated motor power output.

220 V

1~

P2
IA/IN

kW

HP

5,4

3,1

0,75

7,5

3,2

1,1

1,5

1,5

12

18

24

30

36

42

48

200

300

400

500

600

700

800

10

6,5

13

10,5

8,5

6,5

16

13,5

11

7,5

5,5

12

18

24

30

31

35

39

200

300

400

500

516

583

650

3,5

1,5

9,5

6,5

4,5

2,5

2,3

11,5

10

8,5

6,5

4,3

2,5

l/min 100

Hm

m3/h

m3/h

l/min 100

Hm

Density = 1000 kg/m3.

H Total head in m.

Tolerances according to ISO 9906, annex A.

180

Kinematic viscosity = max 20 mm2/sec.

GMC, GMV

60 Hz

Submersible Sewage
and Drainage Pumps

500

Dimensions and weights

180

4.93.107

155

395

ISO 228 G 2

GMC 45
GMV 50

kg

530 max

315

GMV 50CE-60
GMV 50BE-60
GMV 50AE-60
GMVM 50CE-60
GMVM 50BE-60

27
28
29,5
27
28,5

GMC 50CE-60
GMC 50BE-60
GMC 50AE-60
GMCM 50CE-60
GMCM 50BE-60

28
29
30,5
28
29,5

248

kg

505

185
145

GMC 45
GMV 50

kg

530 max

304

GMV 50-65C-60
GMV 50-65B-60
GMV 50-65A-60
GMVM 50-65C-60
GMVM 50-65B-60

118

18

130

M8

32

185

100

400

DN 65

90

181

29
30
31,5
29
30,5
kg

GMC 50-65C-60
GMC 50-65B-60
GMC 50-65A-60
GMCM 50-65C-60
GMCM 50-65B-60

30
31
32,5
30
31,5

GMC, GMV

60 Hz

Submersible Sewage
and Drainage Pumps

Dimensions with duck foot coupling

78
33

13
500 min
12
52

86

600 min
443

83

346

85

223

319

100

2"
3/4"
180

117

575
68

34

255

253

540

EN 1092-2
PN 10

220

22

200
92

120

100

92

198

16

110
166
18
440

531

138

182

530 max
360 min

130

18

185

145

118

530 max
360 min

118

180

130

132

176

80

134

G2 ISO 228

DN 65

GEO 60 Hz

Automatic waste water collecting


and lifting station
Construction
High-density polyethylene tank, resistant to corrosion, with
minimum overall dimensions.

GEO 40

- GEO 40 single tank with 40 liter nominal capacity for the


installation of a GXRM 9 type.
- GEO 230 single tank with 230 liter nominal capacity for the
installation of an electropump type GM 10, GX or GM series.
- GEO 500 double tank with 500 liter nominal capacity for the
installation of two electropumps type GM 10, GX or GM series.
Pipe kit for electropump connection.
Two possible installation, at ground level or underground.
For underground installation, extentions can be used.
Easy pump access through a cover fixed with screws.

GEO 230

Applications
Automatic waste water collecting and lifting stations, to handle
domestic, civil and industrial waste water.
For collecting and lifting clean waste water and rain water.
For flood drainage.

Designation
GEO 40-GXRM 9-60
GEO 500

Series
Nominal tank capacity
Pump type
Pump frequency 60 Hz

GEO 230-GXVM 40B-60


Series
Nominal tank capacity
Pump type
Pump frequency 60 Hz

GEO 500-2 GXVM 40B-60


Series
Nominal tank capacity
Nr of pumps
Pump type
Pump frequency 60 Hz

33

Installation examples
GEO 40-GXR

GEO 230-GX..

183

GEO 500-2GM..

GEO 40 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 40-GXRM 9

GEO 40-GXRM 9 GF

Features
Automatic collecting and lifting station for clean water with GXRM 9 pump
type .

It includes:
1 40 lt capacity tank
1 single-phase pump with 5 m cable and float switch
1 non-return valve with clapet on the pump delivery side
1 discharge pipe kit arranged for the connection of a 40 mm PVC pipe
1 PVC adapting nipple for 40 mm inlet
1 connector for 25 mm flexible pipe

ON DEMAND
1 pump with 10 m cable

Single-phase type

1 ~ 220 V
kW
A

GEO 40-GXRM 9-60


GEO 40-GXRM 9 GF-60

0,25

H max
m

12

8,5

412

2,5

Q max
m3/h

390

350

GXRM 9

GXRM 9 GF

Submersible drainage pump in chrome-nickel stainless steel, for clean water containing
solids up to 10 mm grain size, with vertical delivery port.
Open impeller.
2-pole induction motor, 60Hz (n = 3450 rpm),
Single-phase 220 V +/-10% with float switch and thermal protector.
- GXRM 9: with standard float switch.
- GXRM 9 GF: with vertical magnetic float switch.
Incorporated capacitor.
Cable length 5 m, Shuko plug.
Liquid temperature up to 50 C

GXRM 9
10

GXRM 9
H
m
6

00
0

m3/h
l/min

5
50

10
100

184

150

200

GEO 230 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GM 10

Features
Automatic clear water collecting and lifting station GM 10 pump series.

include:
1 tank capacity 230 lt
1 single-phase pump with 5 m cable and float switch
1 control box QM 6,3 type with capacitor
1 discharge pipe kit 40 mm in PVC

ON DEMAND
1 pump with 10 m cable
1 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball
valve
1 support kit with safety float switch and auto-supplied control panel for
remote alarm with horn and flashing light
- extention 300 mm

GEO 230-GM 10-60

1 ~ 220 V
kW
A
0,3
1,75

Q max
m3/h
12

H max
m
6,5
710

Single-phase type

60

800

GM 10
Submersible drainage pump constructed from composite polymers.
Shaft of chrome steel AISI 430.
2-pole induction motor, 60Hz (n = 3450 rpm).
Single-phase 220 V +/-10% with thermal protector.
Float switch for automatic operation.
5 m cable and control box QM 6,3 with capacitor.
Liquid temperature up to 35 C

0 Imp. g.p.m.10

20

30

40

8
H
m

ft

20
GM 10

4
10
2

0
0

m3/h
l/min

3
50

6
100

185

9
150

0
12
200

33

GEO 230 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GX..

Features
Automatic collecting and lifting station - for clean water GXR pump series.
- for waste water GXV pump series.

include:
1 tank capacity 230 lt
1 single-phase pump with 5 m cable and float switch
1 discharge pipe kit 40 mm in PVC

ON DEMAND
1 pump with 10 m cable
1 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball valve
1 support kit with safety float switch and auto-supplied control panel for remote
alarm with horn and flashing light
- extention 300 mm

GEO 230-GXVM 25-6-60


GEO 230-GXVM 25-8-60
GEO 230-GXVM 25-10-60
GEO 230-GXRM 9-60
GEO 230-GXRM 11-60
GEO 230-GXRM 13-60

Q max
m3/h
10,2
12
13,2
12
13,2
13,2

H max
m
5,7
7,8
9,2
8,5
10,4
12,2

710

1 ~ 220 V
kW
A
0,25
2,5
0,37
3,6
0,45
4,9
0,25
2,5
0,37
3,6
0,45
4,9

Single-phase type

60

8 00

GXRM, GXVM
Submersible drainage pump in chrome-nickel stainless steel, with vertical delivery port.
GXRM: with open impeller.
GXVM: with free-flow (vortex) impeller.
2-pole induction motor, 60Hz (n = 3450 rpm),
Single-phase 220 V +/-10% with float switch and thermal protector. Incorporated capacitor.
Cable length 5 m.
Liquid temperature up to 50 C

GXVM

GXRM

14

14
GXRM

GXVM

12
10

12
GX
RM

1360
1160
GX
RM
9-6
0

10

GX

RM

H
m
6

GXV

0
m3/h
0 Q l/min 50

10
100

150

200

15
250

186

25-1
0-60
M 25
-8-60

GXV

GXV
M

H
m

M 25
-6-60

0
m3/h
0 Q l/min 50

10
100

150

200

15
250

GEO 230 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GX..

Features
Automatic waste water collecting and lifting station GX 40 pump series.

include:
1 tank capacity 230 lt
1 pump - single-phase with 10 m cable and float switch with control box QM
series with capacitor
- three-phase with 10 m cable with support and float switch kit
1 discharge pipe kit 50 mm in PVC

ON DEMAND
1 discharge pipe kit 50 mm in PVC with a ball valve and non-return ball
valve
1 safety float switch (with support for single-phase version) and autosupplied control panel for remote alarm with horn and flashing light
- extention 300 mm
Single-phase type

Q max
m3/h
15
21

H max
m
7
8,6

3 ~ 380 V
kW
A
0,55
1,9
0,9
2,7

Q max
m3/h
15
21

H max
m
7
8,6

710

GEO 230-GXVM 40B-60


GEO 230-GXVM 40A-60

1 ~ 220 V
kW
A
0,55
5,5
0,9
7

Three-phase type
GEO 230-GXV 40B-60
GEO 230-GXV 40A-60

60

800

GXV 40
Submersible sewage and drainage pumps in chrome-nickel stainless steel, with vertical delivery
port.
GXV: with free-flow (vortex) impeller
2-pole induction motor, 60Hz (n = 3450 rpm).
GXV: three-phase 220 V;
three-phase 380 V;
GXVM: single-phase 220 V +/-10%, with thermal protector and float switch for automatic operation.
10 m cable and control box QM serie with capacitor.
Liquid temperature up to 35 C

10

0 Imp. g.p.m.20

30

40

50

60

70

33

80
30

8
H
m
6

ft
GXV 40A

20

GXV 40B
10

0
m3/h
Q
0
l/min

6
100

12
200

18
300
187

0
24
400

GEO 230 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GMGM

Features
Automatic sewage water collecting and lifting station with grinder pumps
GMG series.

include:
1 tank capacity 230 lt
1 single-phase pump with 10 m cable, without float switch
1 support kit with float switch
1 control box
1 duck foot coupling kit
1 discharge pipe kit 63 mm in PVC/inox with a ball valve and non-return
ball valve
ON DEMAND
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm

GEO 230-GMGM 6-40E-60


GEO 230-GMGM 6-40D-60
GEO 230-GMGM 6-40C-60
GEO 230-GMGM 6-40B-60
GEO 230-GMGM 6-40A-60

1 ~ 220 V
kW
A
0,78
5,5
1,1
7,5
1,1
7,5
1,8
10
1,8
10

Q max
m3/h
12
14
16
16
16

H max
m
8
12
15
17,5
22,5

710

Single-phase type

60

8 00

GMGM
Submersible pumps with high power grinder.
2-pole induction motor, 60Hz (n = 3450 rpm)
Single-phase 220 V +/-10% complete control box with thermal protector and capacitors (without
float switch).
10 m cable.
Liquid temperature up to 40 C.

0 Imp. g.p.m.
30

20

30

40

60

50

GMG 6-40

H
m

80

20
ft

B
C
D

40

10
E

0
m3/h
0 Q l/min

10

5
100

15
200

188

GEO 230 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GM..50-65

GEO 230-GM..50

Features
Automatic waste water collecting and lifting station GMV, GMC
series.

include:
1 tank capacity 230 lt
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float
switch
1 control box for three-phase version
1 duck foot coupling kit (for GM..50-65..)
1 discharge pipe kit 63 mm in PVC with a ball valve and nonreturn ball valve

ON DEMAND
1 ~ 220 V
kW
A

Single-phase type
-

GEO 230-GMCM 50-65C-60


GEO 230-GMCM 50-65B-60
GEO 230-GMVM 50-65C-60
GEO 230-GMVM 50-65B-60

0,75
1,1
0,75
1,1

5,4
7,5
5,4
7,5

GEO 230-GMC 50-65C-60


GEO 230-GMC 50-65B-60
GEO 230-GMC 50-65A-60
GEO 230-GMV 50-65C-60
GEO 230-GMV 50-65B-60
GEO 230-GMV 50-65A-60

3 ~ 380 V
kW
A
0,75
2,4
1,1
3,2
1,5
4,6
0,75
2,4
1,1
3,2
1,5
4,6

36
42
31
35

10
13
8
9,5
710

GEO 230-GMCM 50CE-60


GEO 230-GMCM 50BE-60
GEO 230-GMVM 50CE-60
GEO 230-GMVM 50BE-60

Q max Hmax
m3/h
m

1 safety float switch (with support for single-phase version) and


auto-supplied control panel for remote alarm with horn and
flashing light
- extention 300 mm

Three-phase type
GEO 230-GMC 50CE-60
GEO 230-GMC 50BE-60
GEO 230-GMC 50AE-60
GEO 230-GMV 50CE-60
GEO 230-GMV 50BE-60
GEO 230-GMV 50AE-60

Q max H max
m3/h
m
36
10
42
13
48
16
31
8
35
9,5
39
11,5

60

800

GMC, GMV

GM.. 50-65

GM.. 50

20

Submersible sewage and drainage pumps.


GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 60Hz (n = 3450 rpm)
GMV, GMC:
three-phase 220 V; three-phase 380 V;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 220 V 10%, built-in thermal protector and built-in capacitor.
Float switch for automatic operation.
Cable length 10 m.
Liquid temperature up to 35 C.

0 Imp.g.p.m. 50

100

150

15

H
m

60

15

50
A

GMC

0 Imp.g.p.m.

50

33

100

H
m

ft
40

40
GMV

10

ft
30

10

30

20
5

20
5

10

10
0
0
m 3/h 10
Q l/min
0
200

20
300 400

30
500

40
600 700

0
50
800

0
m 3/h
Q
l/min
0
189

10
200

20
300

400

30
500

0
40
600

GEO 500 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-GM 10

Features
Automatic clear water collecting and lifting station with GM 10 pump series.

include:
1 tank capacity 500 lt
2 single-phase pump with 5 m cable without float switch
1 support kit with 2 float switch
1 control box
2 discharge pipe kit 40 mm in PVC

ON DEMAND
2 single-phase pumps with 10 m cable, without float switch
2 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm

GEO 500-2GM 10-60

1 ~ 220 V
kW
A
0,3x2
1,75x2

Q max
m3/h
12x2

H max
m
6,5

710

Single-phase type

12

00
800

GM 10
Submersible drainage pump constructed from composite polymers.
Shaft of chrome steel AISI 430.
2-pole induction motor, 60Hz (n = 3450 rpm).
Single-phase 220 V +/-10% with thermal protector (without float switch).
5 m cable and control box with capacitor.
Liquid temperature up to 35 C

0 Imp. g.p.m.10

20

40

30

8
H
m

ft
20

6
GM 10
4

10
2

0
0

m3/h
l/min

3
50

6
100

190

9
150

0
12
200

GEO 500 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GX..

Features
Automatic collecting and lifting station - for clean water with GXR pump series
- for waste water with GXV pump series.

include:
1 tank capacity 500 lt
2 single-phase pump with 5 m cable without float switch
1 support kit with 2 float switch
1 control box
2 discharge pipe kit 40 mm in PVC

ON DEMAND
2 single-phase pumps with 10 m cable, without float switch
2 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm
Q max
m3/h
10,2x2
12x2
13,2x2
12x2
13,2x2
13,2x2

H max
m
5,7
7,8
9,2
8,5
10,4
12,2

710

1 ~ 220 V
kW
A
GEO 500-2GXVM 25-6-60 0,25x2
2,5x2
GEO 500-2GXVM 25-8-60 0,37x2
3,6x2
GEO 500-2GXVM 25-10-60 0,45x2
4,9x2
GEO 500-2GXRM 9-60
0,25x2
2,5x2
GEO 500-2GXRM 11-60
0,37x2
3,6x2
GEO 500-2GXRM 13-60
0,45x2
4,9x2
Single-phase type

12

00
800

GXRM, GXVM
Submersible drainage pump in chrome-nickel stainless steel, with vertical delivery port.
GXRM: with open impeller.
GXVM: with free-flow (vortex) impeller.
2-pole induction motor, 60Hz (n = 3450 rpm),
Single-phase 220 V +/-10% with float switch and thermal protector. Incorporated capacitor.
Cable length 5 m.
Liquid temperature up to 50 C

GXVM

GXRM

14

GXVM

12
10

12
GX
RM

1360
1160
GX
RM
9-6
0

10

GX

RM

H
m
6

GXV

GXV

GXV

0
m3/h
0 Q l/min 50

10
100

150

200

15
250
191

M2

5-10
-60
M 25
-8-60

H
m

33

14
GXRM

M 25
-6-60

0
m3/h
0 Q l/min 50

10
100

150

200

15
250

GEO 500 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GX..

Features
Automatic waste water collecting and lifting station with GX 40 pump
series.

include:
1 tank capacity 500 lt
2 pumps - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with 2 float switch
1 electric control box (with capcitor for single-phase motors)
2 discharge pipe kit 50 mm in PVC

ON DEMAND
2 discharge pipe kit 50 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm
Single-phase type

Q max
m3/h
15x2
21x2

H max
m
7
8,6

3 ~ 380 V
kW
A
0,55x2
1,9x2
0,9x2
2,7x2

Q max
m3/h
15x2
21x2

H max
m
7
8,6

710

GEO 500-2GXVM 40B-60


GEO 500-2GXVM 40A-60

1 ~ 220 V
kW
A
0,55x2
5,5x2
0,9x2
7x2

Three-phase type
GEO 500-2GXV 40B-60
GEO 500-2GXV 40A-60

12

00
800

GXV 40
Submersible sewage and drainage pumps in chrome-nickel stainless steel, with vertical delivery port.
GXV: with free-flow (vortex) impeller
2-pole induction motor, 60Hz (n = 3450 rpm).
GXV: three-phase 220 V;
three-phase 380 V;
GXVM: single-phase 220 V +/-10%, with thermal protector (without float switch).
10 m cable
Capacitor in the control box (for pumps with single phase motor)
Liquid temperature up to 35 C

10

0 Imp. g.p.m.20

30

40

50

60

70

80
30

8
H
m
6

ft
GXV 40A

20

GXV 40B
10

0
m3/h
Q
0
l/min

6
100

12
200
192

18
300

0
24
400

GEO 500 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GMGM

Features
Automatic sewage water collecting and lifting station with grinder pumps
GMG series.

include:
1 tank capacity 500 lt
2 single-phase pumps 10 m cable, without float switch
1 support kit with 2 float switch
1 electric ocntrol box (with capacitor for single-phase motors)
2 duck foot coupling kit
2 discharge pipe kit 63 mm in PVC/inox with a ball valve and non-return
ball valve

ON DEMAND
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extension 300 mm

GEO 500-2GMGM 6-40E-60


GEO 500-2GMGM 6-40D-60
GEO 500-2GMGM 6-40C-60
GEO 500-2GMGM 6-40B-60
GEO 500-2GMGM 6-40A-60

1 ~ 220 V
kW
A
0,78x2
5,5x2
1,1x2
7,5x2
1,1x2
7,5x2
1,8x2
10x2
1,8x2
10x2

Q max
m3/h
12x2
14x2
16x2
16x2
16x2

H max
m
8
12
15
17,5
22,5
710

Single-phase type

12

00
800

GMGM
Submersible pumps with high power grinder.
2-pole induction motor, 60Hz (n = 3450 rpm)
Single-phase 220 V +/-10% with thermal protector (without float switch).
Capacitors in the control box
10 m cable.
Liquid temperature up to 40 C.

0 Imp. g.p.m.
30

20

30

40

33

60

50

GMG 6-40

H
m

80

20
ft

B
C
D

40

10
E

0
m3/h
0 Q l/min

10

5
100

15
200

193

GEO 500 60 Hz

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GM..50

GEO 500-2GM..50-65

Features
Automatic waste water collecting and lifting station GMV, GMC series.

include:
1 tank capacity 500 lt
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 duck foot coupling kit (for GEO 500-2GMC(M) 50-65..)
2 discharge pipe kit 63 mm in PVC/inox with a ball valve and
non-return ball valve

ON DEMAND
1 safety float switch and auto-supplied control panel for remote
alarm with horn and flashing light
- extention 300 mm
Single-phase type
GEO 500-2GMCM 50CE-60 GEO 500-2GMCM 50BE-60 GEO 500-2GMVM 50CE-60 GEO 500-2GMVM 50BE-60 -

GEO 500-2GMCM 50-65C-60


GEO 500-2GMCM 50-65B-60
GEO 500-2GMVM 50-65C-60
GEO 500-2GMVM 50-65B-60

1 ~ 220 V
kW
A
0,75x2 5,4x2
1,1x2 7,5x2
0,75x2 5,4x2
1,1x2 7,5x2

Q max Hmax
m3/h
m
36x2
10
42x2
13
31x2
8
35x2
9,5

3 ~ 380 V Q max H max


kW
A
m3/h
m
GEO 500-2GMC 50CE-60 - GEO 500-2GMC 50-65C-60 0,75x2 2,4x2 36x2
10
GEO 500-2GMC 50BE-60 - GEO 500-2GMC 50-65B-60 1,1x2
3,2x2 42x2
13
GEO 500-2GMC 50AE-60 - GEO 500-2GMC 50-65A-60 1,5x2
4,6x2 48x2
16
GEO 500-2GMV 50CE-60 - GEO 500-2GMV 50-65C-60 0,75x2 2,4x2 31x2
8
GEO 500-2GMV 50BE-60 - GEO 500-2GMV 50-65B-60 1,1x2
3,2x2 35x2
9,5
GEO 500-2GMV 50AE-60 - GEO 500-2GMV 50-65A-60 1,5x2
4,6x2 39x2
11,5

710

Three-phase type

12

00
800

GMC, GMV

GM.. 50-65

GM.. 50

20

Submersible sewage and drainage pumps.


GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 60Hz (n = 3450 rpm)
GMV, GMC:
three-phase 220 V; three-phase 380 V;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 220 V 10%, built-in thermal protector and built-in capacitor.
(without float switch)
Cable length 10 m.
Liquid temperature up to 35 C.

0 Imp.g.p.m. 50

100

150

15

H
m

60

15

50
A

GMC

0 Imp.g.p.m.

50

100

H
m

ft
40

40
GMV

10

ft
30

10

30

20
5

20
5

10

10
0
0
m 3/h 10
Q l/min
0
200

20
300 400

30
500

40
600 700

0
50
800

0
m 3/h
Q
l/min
0
194

10
200

20
300

400

30
500

0
40
600

GEO 60 Hz

Automatic waste water collecting


and lifting station

Dimensions and weights

GEO 40

370

330

Tank
Serbatoio
kg.6
kg. 6

130

B
315

335

415

4.93.433

300

350

340

A) Arrangement for :
40 mm inlet
40 mm outlet
25 mm relief
B) Cable passage with Shuko plug

390

580

GEO 230

485

Prolunga
Extention

300

kg. 4,5
kg.4,5

E
450

545

Serbatoio
Tank

kg. 16
kg.16

B
C

570

510

A
C

125 125
410

710

15

33

4.93.373

600

125 125

800

A-C)
B)
D)
E)

inlet and relief


delivery outlet
G 1 1/2 draining outlet
Cable outlet

C
A
D

100

195

GEO 60 Hz

Automatic waste water collecting


and lifting station

Dimensions and weights


580

Extention
Prolunga
kg. 4,5 kg. 4,5

485

300

GEO 500

Tank Serbatoio
kg. 32 kg. 32
600

545

450

450

B
C

510

570
420

710

15

B
C

125 125

125 125

C
A
C
4.93.389

800

1200

125

125

97

125 125

A-C)
B)
D)
E)

inlet and relief


delivery outlet
G 1 1/2 draining outlet
Cable outlet

A
D

Installation examples

4.93.267

196

GM 60 Hz

Submersible Pumps

34

197

GM 60 Hz

Submersible Pumps

GMV

Submersible pumps with vortex impeller in cast iron EN-GJL-250

pag. 202

Submersible pumps with single channel impeller in cast iron EN-GJL-250

pag. 211

Submersible pumps with channels impeller in cast iron EN-GJL-250

pag. 220

Submersible pumps with grinder in cast iron EN-GJL-250

pag. 234

Submersible pumps with vortex impeller in stainless steel AISI316

pag. 238

Submersible pumps with single channel impeller in stainless steel AISI316

pag. 238

Submersible pumps with channels impeller in stainless steel AISI316

pag. 238

Submersible pumps with vortex impeller in Marine Bronze B10

pag. 249

Submersible pumps with single channel impeller in Marine Bronze B10

pag. 249

Submersible pumps with channels impeller in Marine Bronze B10

pag. 249

GMC

GMN

GMG

I-GMV

I-GMC

I-GMN

B-GMV

B-GMC

B-GMN

198

GM 60 Hz

Submersible Pumps

A new series of submersible pumps with high efficiency


hydraulics designed to move slurry, sewage and industrial
process fluids.
The range covers a wide field of use with head up to 75 m And
flows up to 2300 m3/h, with a maximum solid passage up to
140 mm keeping the risk of blockage to a minimum.
Dimensionally designed for heavy demand, even on critical
applications.

Pump designation
B-GM V 4 M 50-80 A-60
Version B = bronze
I = stainless steel
(no indication: cast iron version)
Series
Impeller type V = Vortex
C = Singlechannel
N = Channels
G = Grinder

Explosion proof version on request.

4-6-8 poles motor (no indication: 2 poles)


Singlephase M (no indication: threephase)
Free passage
Discharge diameter in mm
Pump size
Frequency 60 Hz

THE IMPELLERS

THE STANDARD INSTALLATIONS


Vortex impeller suitable for pumping
liquids containing large solids and/or
fibrous materials.
Applications: urban sewerage systems,
animal breeding plants.

A Mobile and emergency installation


with x-foot support

Single channel impeller, for liquids


containing fibrous materials and/or
suspended solids.
Applications: purification plants, tanneries, animal breeding plants.

B Free installation and threated elbow

Closed multi-channel impeller, for clean


liquids or light solids without filamentous
materials.
Applications: large drainage systems,
purification plants.

C Fixed installation with automatic


coupling feet and guide rails.

Multi-blade suction impeller with grinder


constructed in stainless steel AISI 440,
particularly suitable as a grinder for paper
or textile materials.
Applications: clearance of waste waters
originating from service stations, residential
communities, camping sites, etc..

D Dry pit installation, with x-foot rest


and suction bend.
Pump equipped with cooling jacket.

GMV

GMC

34

GMN

GMG

199

GM 60 Hz

Submersible Pumps

Coverage chart

80

GM

70

60 Hz
60

H
m

GMC

50

40

GMN

GMV

GMN4-6-8

30

20
GMC4

10

GMV4

m 3/h

10

20

30

40 50

100

200

500

1000

72.2000

2000

3000

Tolerances according to ISO 9906, annex A.

200

GM 60 Hz

Submersible Pumps

Features

Motor shaft made of stainless steel AISI 420B


over dimensioned for heavy duty

Dry motor for increased safety

Bearings over dimensioned for


heavy duty

Intermediate oil chamber for


a correct lubrication and
cooling.

Twin mechanical seal

34

Impellers and volutes are developed to optimize the


hydraulic efficiency and provide a clear exit for filamentous
and solid materials.

201

GMV 60 Hz

Submersible pumps
with vortex impeller
Construction
Submersible pumps with vortex impeller.
Twin mechanical seal with oil chamber.
Delivery connection DN 80-100-150.

Applications
Suitable to pump slurry and sewage waters with the presence of
solid and filamentous parts in suspension, they are in particular
pointed out for emptying sceptic tanks in the domestic, residential and industrial installations.
Solid passage diameter from 50 to 100 mm.

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 or 4 poles induction, 60Hz
Three-phase version: 380V 10%, up to 3,2 kW
380/660V 10%, over 3,2 kW
Insulation Class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office

Main materials
Pump casing: cast iron EN-GJL-250
Impeller: cast iron EN-GJL-250+Ni
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Shaft: stainless steel AISI 420B
Mechanical seal motor side: graphite/ceramic
Mechanical seal pump side: silicon carbite/silicon carbite

Coverage chart
50
40

GMV

30
GMV 80-80

60 HZ

20
GMV 50-80

H
m
10

GMV4 90-100

GMV 50-50

GMV4 50-65

GMV4
80-100

GMV4 65-80

4
3

72.2001

GMV 30

2
5

3
Q m /h

10

15

20

30

40

202

50

100

150

200

300

GMV 60 Hz

Submersible pumps
with vortex impeller

Technical data
Power Supply

TYPE

GMVM 30A-60
GMV
30A-60
GMVM 50-50C-60
GMV
50-50C-60
GMVM 50-50B-60
GMV
50-50B-60
GMVM 50-50A-60
GMV
50-50A-60
GMVM 60-80A-60
GMV
60-80A-60
GMV
50-80F-60
GMV
50-80E-60
GMV
50-80D-60
GMV
50-80C-60
GMV
80-80B-60
GMV
80-80A-60
GMV6 50-65B-60
GMV6 50-65A-60
GMV4M 50-65B-60
GMV4 50-65B-60
GMV4M 50-65A-60
GMV4 50-65A-60
GMV6 50-80B-60
GMV6 50-80A-60
GMV4M 50-80B-60
GMV4 50-80B-60
GMV4M 50-80A-60
GMV4 50-80A-60
GMV4 65-80C-60
GMV4 65-80B-60
GMV4 65-80A-60
GMV4 90-100B-60
GMV4 90-100A-60
GMV4 90-100S-60
GMV6 80-100A-60
GMV4 80-100A-60
P2 Rated power output

P2
kW
0,5
0,5
1,8
2,4
1,8
2,4
2,6
2,9
1,8
2,4
3,2
5,9
5,9
5,9
13,8
18,2
0,71
0,71
1,2
1,3
1,2
1,3
0,71
0,71
1,2
1,3
1,2
1,3
2,9
4,6
4,6
5,1
7,1
14,1
5,2
14,1

IN
A
4
1,5
10
5
10
5
16
6
10
5
6,5
13
13
13
29,5
34
2,5
2,5
8,5
3,5
8,5
3,5
2,5
2,5
8,5
3,5
8,5
3,5
6,5
9,5
9,5
11
13,5
30
12,5
30

IN Rated current

1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V

Starting

r.p.m.
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
1150
1150
1750
1750
1750
1750
1150
1150
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
1150
1750
Standard

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
30
30
50
50
50
50
50
50
80
80
80
80
80
80
80
80
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
100
100
100
100
100

mm
1 1/4
1 1/4
50
50
50
50
50
50
60
60
50
50
50
50
80
80
50
50
50
50
50
50
50
50
50
50
50
50
65
65
65
90
90
90
80
80

Thermal
protector

Humidity
probe

ATEX
Eex
NO
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO

ATEX Eex Version on demand

34

203

GMV 60 Hz

Submersible pumps
with vortex impeller

Characteristic curves
0

U.S. g.p.m.

0
10

Imp. g.p.m.

20

30

50

40

20

30

60

40

50

U.S. g.p.m.

0 Imp. g.p.m.

60

40

100

80

120

80

60

140

100

160

120

140

20

30

GMV 30A-60

60

GMV 50-50..60
n = 3450 1/min

n = 3450 1/min

ft

15

H
m

20

H
m

ft

40

B
C

10

4
10

20
5

0
0

m3/h
Q l/min

10

100

0
15

200

40

40

30
%
20

m3/h
Q l/min

20

10
200

30

400

40

600

30

10

0,8

2,5

0,6
P2
0,4
kW
0,2

20

10

0
0

B
A
B

2
P2
kW
1

0,5
0
0

m3/h
Q l/min

10

100

15

200

0
0

m3/h
Q l/min

10

20

200

30

400

40

600

72.2010

0 U.S. g.p.m. 50
0 Imp. g.p.m.

100

150

200

100

50

72.2013

0 U.S. g.p.m. 50

150

0 Imp. g.p.m.

100

150
100

50

200
150

10

GMV6 50-65..60

GMV4 50-65..60

n = 1150 1/min

n = 1750 1/min

15

H
m

4
H
m

ft

30

ft

20

10

4
2

10
5
2

0
0

m 3/h
Q l/min

10

250

20

40

30
500

750

50

40

40

30

m 3/h
Q l/min

10

250

20

30
500

40

750

50

30

20

20

10

10

2
1,5
P2
1
kW
0,5

P2
0,5
kW
0

0
0

B
0
0

m 3/h
Q l/min

10

250

20

30
500

40

750

50
72.2007

A
B
0
0

m 3/h
Q l/min

10

250

20

30
500

40

750

50
72.2007

204

GMV 60 Hz

Submersible pumps
with vortex impeller

Characteristic curves
0

U.S. g.p.m.

0 Imp. g.p.m.

120

80

160

200

240

160

120

280

200

320

240

280

U.S. g.p.m.

0 Imp. g.p.m.

120

80

160

200

240

160

120

280

200

240

320
280

10
15

GMV6 50-80..60
4

n = 3450 1/min

ft

H
m

30

GMV4 50-80..60

n = 1150 1/min

ft

H
m

10

20

B
2

4
5

10

0
0

m3/h
Q l/min

40

20
400

60

800

1200

80

40

50

30
%
20

m3/h
Q l/min

40

20
400

60

800

1200

80

40

1,6

1
P2
kW
0,4

0,2
0
0

m3/h
Q l/min

20

40

400

10

0,8
P2
kW
0,4

20

10

0
0

800

60

1200

80

0
0

m3/h
Q l/min

20

40

400

60

800

1200

72.2013

U.S. g.p.m.

Imp. g.p.m.

200

300
200

400

500
400

300

80
72.2013

U.S. g.p.m.

600

500

0 Imp. g.p.m.

15

120

80

160
120

240

200
160

280
240

200

320
280

10

GMV4 65-80..60

n = 1750 1/min

30

GMV 60-80..60
40

n = 3450 1/min

ft

H
m

10

ft

20

C
20

10
2

0
0

m3/h
Q l/min

50

1000

100

60
50
%
30
20
10
0
6
5
P2
kW
3
2
1
0

0
150

2000

0
0

m3/h
Q l/min

20
400

40

800

60

1200

80

40
30

%
20

A
B

10

0
2,5

B
C
0
0

m /h
Q l/min
3

50

1000

100

2
P2
kW
1

0,5

2000

150
72.2009

0
0

m3/h
Q l/min

20

400

40

800

60

1200

80
72.2013

205

34

GMV 60 Hz

Submersible pumps
with vortex impeller

Characteristic curves
0

U.S. g.p.m.

0 Imp. g.p.m.

150
100

250

200

300

200

150

350

250

400

300

350

25

U.S. g.p.m.

0 Imp. g.p.m.

GMV 50-80..60

15
H
m

E
F

10

600

400

700

500

800

600

700

60

30

ft

H
m

40

20

20

10

120

GMV 80-80..60

n = 3450 1/min

500

400
300

40

80

20

300

200

n = 3450 1/min
ft

80

40
5

0
0

m 3/h
Q l/min

20

500

40

80

60
1000

1500

0
100

40

60

30
%
20

m3/h
Q l/min

100

50
1000

2000

150

0
200

3000

40

10

D
E

20

B
0

20

6
P2
4
kW
2
0

0
0

P2
15
kW

D
F
0
0

m 3/h
Q l/min

20

500

40

A
B

10
80

60
1000

1500

100

0
0

m3/h
Q l/min

100

50
1000

2000

150

0 U.S. g.p.m.

600

400

0 Imp. g.p.m. 200

400

800
600

200

3000

72.2007

72.2011

1000
800

25

U.S. g.p.m.

Imp. g.p.m.

400

600

800

400

600

1000

1200

800

1000

20
75

GMV4 90-100..60
S

20

GM

V4

50

15

n = 1750 1/min (n = 1150 1/min)

m
15

ft

H
m

80

-1

10

60

GMV4(6) 80-100..60

n = 1750 1/min

GM

10

V6

25

00

80

40

A-

-10

60

0A

ft

-60

20

0
0

m3/h
Q l/min

60
1000

120
2000

0
240
4000

180
3000

60

S
A

0
14

14
12
P2
kW
8
6
4
2

10
P2
kW
4

A
B
0
0

m3/h
Q l/min

60
1000

120
2000

180
3000

0
0

m3/h
Q l/min

60
50
%
30
20
10
0

B
40
%
20

240
4000
72.2013

100

200

2000
GM
V6
8

0-1

0
300

4000

0 0A
-60
GM
V4
80

-10
0

A-6
0

A-60
GMV4 80-100

0
GMV6 80-100A-6

0
0

m3/h
Q l/min

100
2000

200

4000

300
72.2009

206

GMV 60 Hz

Submersible pumps
with vortex impeller

Dimensions and weights

202

346

GMV 30..-60

GMVM 30A-60
GMV 30A-60

56

Weight
kg

TYPE

1"1/4

14

90

100

134

GMV 50-50..60

52
12

86

450 min.
312
194

544

3/4

330

50
125

75

28

G 2

268

134

HL minimum submersible level

176

55
150

132
100

13

110

403

156

252

16

136

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMVM 50-50C-60
GMV 50-50C-60
GMVM 50-50B-60
GMV 50-50B-60
GMVM 50-50A-60
GMV 50-50A-60

Weight
kg

43

207

400 min

50

90

112 112

392

34

GMV 60 Hz

Submersible pumps
with vortex impeller

Dimensions and weights

GMV4 50-65..60
GMC6 50-65..60
13
78
83

600 min
447

33

85

317

100

180

117

DN 65

121

335

60

47

556

253

EN 1092-2
PN 10

200
HL minimum submersible level

50

92

92

180
198
120

310

18
451
720

283

1/

15

15

96

90

130 130

69

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMV6 50-65B-60
GMV6 50-65A-60
GMV4M 50-65B-60
GMV4 50-65B-60
GMV4M 50-65A-60
GMV4 50-65A-60

Weight
kg
40

42

208

360 min.

181

GMV 60 Hz

Submersible pumps
with vortex impeller

Dimensions and weights


13

GMV 50-80..60
GMV 60-80..60
GMV 80-80..60
GMV4 50-80..60
GMV4 65-80..60
GMV6 50-80..60

d1 min.

78

83

d2

33

85

d3

100

180

116

DN2

370
256

f
DN2

200

HL

hf
h1

GMV
50-80
60-80

GMV4
65-80

HL minimum submersible level

DN1
L2

GMV
80-80

250
100

L1

100

20

210

160

L4

160

50-80

210

GMV6
L3
18
d4
131

h2

a1

140

a2

412 min

75

170

194

Version with duck foot coupling

Version with foot and 90 elbow


EN 1092-2
PN 10

TYPE
GMVM
GMV
GMV
GMV
GMV
GMV
GMV
GMV
GMV4M
GMV4
GMV4M
GMV4
GMV4
GMV4
GMV4
GMV6
GMV6

60-80A-60
60-80A-60
50-80F-60
50-80E-60
50-80D-60
50-80C-60
80-80B-60
80-80A-60
50-80B-60
50-80B-60
50-80A-60
50-80A-60
65-80C-60
65-80B-60
65-80A-60
50-80B-60
50-80A-60

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

h2

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

80

80

533

314

104

100

673

132

132

660

498

366

775

332

200

273

442

80

80

487

330

116

84

627

149

149

660

541

392

821

395

246

380

570

kg
48
40
60

80

80

553

365

116

84

693

149

149

660

541

392

821

395

246

380

570

77

80

80

863

548

60

140 1018 169

175

900

671

481

950

505

315

388

612

190

80

80

533

314

104

100

673

132

132

660

498

366

775

332

200

273

442

47

80

80

516

380

80

121

656

143

169

700

548

396

828

402

250

323

512

63

80

80

575

400

80

121

715

143

169

700

548

396

828

402

250

323

512

79

80

80

533

314

104

100

673

132

132

660

498

366

775

332

200

273

442

40

209

34

GMV 60 Hz

Submersible pumps
with vortex impeller

Dimensions and weights

GMV4 90-100..60
GMV4 80-100..60
GMV6 80-100..60

13
78

83

d1 min.

33

d2
d3

85

100

190

116

GMV4
80-100

400

h1
HL minimum submersible level

DN1

hf

266

220
GMV4
90-100

DN2

HL

DN2

L2
L1

L4

20

210
160

L3

250
100

160
210

100

18
d4
131
100

a1

150

a2

550 min

h2

250

250

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMV4 90-100B-60
GMV4 90-100A-60
GMV4 90-100S-60
GMV4 80-100A-60
GMV6 80-100A-60

EN 1092-2
PN 10

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

h2

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

kg

125

100

785

490

89

111

935

180

180

800

633

443

933

468

277

367

369

160

125
125
125

100
100
100

890
890
808

570
570
526

54
54
54

147 1040 189


147 1040 189
147 958 189

212
212
212

800
80
800

640
640
640

445
445
445

940
940
940

474
474
474

279
279
279

369
369
369

614
614
614

175
200
166

210

GMC 60 Hz

Submersible pumps
with single channel impeller
Construction
Submersible pumps with single channel impeller.
Twin mechanical seal with oil chamber (lip-seal motor side up to
1,4 kW).
Delivery connection DN 80-100-150

Applications
Suitable to pump slurry, sewage, waste water (non-corrosive).
In industrial and residential installations and drainag applications
Solid passage from 40 to 100mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 or 4 poles induction, 60Hz
Single-phase version: 220V 10%, with float switch and built-in
capacitor.
Three-phase version: 380V 10%, up to 3,2 kW
380/660V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office

Main materials
Pump casing: cast iron EN-GJL-250 - Impeller: cast iron EN-GJL-250+Ni
Motor casing, Motor cover: cast iron EN-GJL-250
Motor shaft: stainless steel AISI 420B
Lip seal made of nitrile up to 1,4 kW
Mechanical seal motor side: graphite/ceramic over 1,4 kW
Mechanical seal pump side: silicon carbite/silicon carbite

Coverage chart
100

GMC

50
40

60 HZ

GMC 40-80

30

34

20

GMC4 100-150

GMC4 80-100

GMC 30-65

10

GMC4 65-80

5
4

GMC4 40-65
72.2002

3
2
5

Q m3/h

10

15

20

30

40

50

211

100

150

200

300

400

500

GMC 60 Hz

Submersible pumps
with single channel impeller

Technical data
Power Supply

TYPE

GMCM 30-65A-60
GMC
30-65A-60
GMC
40-80A-60
GMC4M 30-65B-60
GMC4 30-65B-60
GMC4M 30-65A-60
GMC4 30-65A-60
GMC4M 40-65A-60
GMC4 40-65A-60
GMC6 65-80B-60
GMC6 65-80A-60
GMC4 65-80A-60
GMC6 80-100B-60
GMC6 80-100A-60
GMC6 90-100A-60
GMC4 80-100B-60
GMC4 80-100A-60
GMC4 100-150B-60
GMC4 100-150A-60
P2 Rated power output

P2
kW
1,8
2,4
18,2
0,67
0,85
0,67
0,85
0,67
0,85
0,71
2,3
4,6
2,3
3,4
5,2
7,1
12,1
35,7
35,7

IN
A
10
5
34
5
2,5
5
2,5
5
2,5
2,5
6
9,5
6
8,5
12,5
13,5
27
65,5
65,5

IN Rated current

1~ 220V
3~ 380V
3~ 380/660V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380V
3~ 380/660V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V

Starting

r.p.m.
3450
3450
3450
1750
1750
1750
1750
1750
1750
1150
1150
1750
1150
1150
1150
1750
1750
1750
1750
Standard

212

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
65
65
80
65
65
65
65
65
65
80
80
80
100
100
100
100
100
150
150

Thermal
protector

Humidity
probe

ATEX
Eex

mm
30
30
40
30
30
30
30
40
40
65
65
65
80
80
90
80
80
100
100

NO

NO
NO

NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO

NO

NO

NO
NO

ATEX Eex Version on demand

GMC 60 Hz

Submersible pumps
with single channel impeller

Characteristic curves
0
0

U.S. g.p.m.

40

60

100

80

40

Imp. g.p.m.

80

60

120

0 U.S. g.p.m. 50

100

0 Imp. g.p.m.

10

100

200

150
100

50

150

10
30

GMC4 30-65..60
n = 1750 1/min

30

GMC4 40-65..60
n = 1750 1/min

H
m

ft

H
m

20

ft

20

A
4

B
10

10
2

0
80

0
m3/h
Q l/min
0

200

300

0
30
500

20

10
100

400

10

200

20

400

30

40

50
800

20

20

600

40
%

40

0,5

0,4
P2
kW
0,2

0,8
P2
kW
0,4

A
B

0,2

0,1
0

0
m3/h
0 Q l/min

60

0
0
m3/h
Q l/min
0

20

10
100

200

300

0
m3/h
0 Q l/min

30
500

400

0 Imp. g.p.m.

100

20

400

30

600

40

50
800

200

150
100

50

200

72.2018

72.2017

0 U.S. g.p.m. 50

10

150

25

80

GMC 30-65..60
n = 1750 1/min

ft

20

60

15
H
m

40

10

20

34

0
m3/h
0 Q l/min

10

200

20

400

30

600

40

50
800

60

40
%

20
0
2
1,6
P2
kW
0,8

0,4
0
0
m3/h
0 Q l/min

10

200

20

400

30

600

40

50
800
72.2018

213

GMC 60 Hz

Submersible pumps
with single channel impeller

Characteristic curves
0 U.S. g.p.m. 100
0 Imp. g.p.m.

200

0 U.S. g.p.m. 50

400

300
200

100

0 Imp. g.p.m.

300

100

200

150
100

50

150

20

10
30

GMC6 65-80..60
n = 1150 1/min

16

H
m

60

GMC4 65-80..60

n = 1750 1/min

ft

H
m

ft

20

12

40

20

10
4

0
m3/h
0 Q l/min

20
400

40

60

800

1200

80

100
1600

10

200

20

40
%

20

20

600

40

50
800

40

50
800

4
P2
kW
2

A
B

0,4

30

A
B

1,6
P2
kW
0,8

400

60

60
40
%

0
m3/h
0 Q l/min

1
0

0
0
m3/h
0 Q l/min

20
400

40

60

800

1200

80

0
m3/h
0 Q l/min

100
1600

0 Imp. g.p.m.

100

200

150
100

50

150

70

GMC 40-80..60
n = 1750 1/min

220
200

60

180
ft
160

50
H
m

140

40
120
100

30

80
20
0
m3/h
0 Q l/min
60

10

200

20

400

30

600

40

50
800

40
%
20
0
20

16
P2
kW
8
4
0
0
m3/h
0 Q l/min

10

200

20

400

30

600

40

200

20

400

30

600

72.2018

72.2018

0 U.S. g.p.m. 50

10

50
800
72.2018

214

GMC 60 Hz

Submersible pumps
with single channel impeller

Characteristic curves
0 U.S. g.p.m. 200

400

200

0 Imp. g.p.m.

600

800

400

600

20

15

U.S. g.p.m.

400

600

800

400

Imp. g.p.m.

1000

600

800
60

GMC6 80-100..60

GMC6 90-100..60

40

n = 1150 1/min

n = 1150 1/min

50

15
10

H
m

30

H
m

ft

10

ft
40

30
20

ft

20
5
10
10

0 Q m 3/h
l/min
0

40

80

120
2000

1000

0
200

160

3000

80

80

6
5

0 Q m 3/h
l/min
0

40

80

120
2000

1000

3000

P2
3
kW

P2
1
kW

0
250
4000

200

150
2000

20

100

%
40

40
20

m3/h
Q l/min 50
1000

0
0

160

1
0

200
3000

0
0

m3/h
Q l/min 50
1000

100

200

150
2000

250
4000

3000

72.2016

72.2014

0
0

U.S. g.p.m.

400

600
400

Imp. g.p.m.

1000

800
600

800

1200

1000

30

GMC4 80-100..60

n = 1750 1/min

1200
800

1600

2000
1600

1200

2400
2000
160

GMC4 80-100..60
80

n = 1750 1/min

40

H
m

60

30

40

20

20

120
ft

15

800

50

ft

U.S. g.p.m.
Imp. g.p.m.

80

10
40

20

10

0
80

0
m3/h
Q l/min
0
1000

200

100
2000

3000

4000

0
300
5000

80

0
600
10000

400

200
4000

6000

8000

40

20

40

0
50

10
P2
kW
6

20

12

40
P2
kW
20

A
B

4
2

0
m3/h
Q l/min
0
2000

34

A
B

10
0
m /h
Q l/min
0
1000
3

0
200

100
2000

3000

4000

300
5000
72.2017

0
m3/h
Q l/min
0
2000

400

200
4000

6000

8000

600
10000
72.2017

215

GMC 60 Hz

Submersible pumps
with single channel impeller

Dimensions and weights

GMC 30-65..60
GMC4 30-65..60
GMC4 40-65..60

13
78
83

600 min
447

33

85

317

100

180

117

DN 65

121

335

60

47

556

253

EN 1092-2
PN 10

200
HL minimum submersible level

50

92

92

180
198
120

310

18
451
720

283

15

15

96

90

2
1/

130 130

69

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMCM 30-65A-60
GMC
30-65A-60
GMC4M 30-65B-60
GMC4 30-65B-60
GMC4M 30-65A-60
GMC4 30-65A-60
GMC4M 40-65A-60
GMC4 40-65A-60

Weight
kg
40

37

38

216

360 min.

181

GMC 60 Hz

Submersible pumps
with single channel impeller

Dimensions and weights

GMC 40-80..60
GMC4 65-80..60
GMC6 65-80..60

13

d1 min.

78
83

d2
33

85

d3

100

180

116

DN2

370
256

DN2
200

HL

HL minimum submersible level

DN1
L2

250

L1

L4

100

20

160

210

100

L3

210

GMC4
65-80

160

GMC
40-80

hf
h1

18
d4
131

h2

a1

140

a2

412 min

75

170

34

194

Version with foot and 90 elbow

TYPE

EN 1092-2
PN 10

GMC 40-80A-60
GMC6 65-80B-60
GMC6 65-80A-60
GMC4 65-80A-60

DN1
80
80
80
80

DN2
80
80
80
80

Version with duck foot coupling

Dimensions
mm
f
859
533
519
582

HL
523
330
360
395

hf
85
104
84
84

h1
h2
a1
116 1010 168
84 673 132
116 659 136
113 725 136

217

a2
168
132
157
157

d1
750
658
658
700

d2
603
498
511
511

Weight
d3
416
366
366
366

d4
883
775
791
791

L1
437
332
365
365

L2
250
200
220
220

L3
323
273
293
393

L4
547
442
475
475

kg
190
45
67
67

GMC 60 Hz

Submersible pumps
with single channel impeller

Dimensions and weights

GMC4 80-100..60
GMC6 80-100..60
GMC6 90-100..60

13
78
83

d1 min.
33

d2
d3

85

100

190

116

HL minimum submersible level

DN1

GMC6
90-100
GMC4
80-100

400

h1

hf

266

L2
L1

100

L4

20

210
160

L3

250
100

160
210

220

GMC6
80-100

DN2

HL

DN2

18
d4
131
100
h2
550 min

a1

150

a2

250

250

Version with foot and 90 elbow

TYPE
GMC6 80-100B-60
GMC6 80-100A-60
GMC6 90-100A-60
GMC4 80-100B-60
GMC4 80-100A-60

Version with duck foot coupling

EN 1092-2
PN 10

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

h2

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

kg

125

100

597

420

62

138

747

180

231

850

673

466

973

507

300

390

647

110

125
125
125

100
100
100

808
808
890

520
520
570

54
54
54

147 958 189


147 958 189
147 1040 189

212
212
212

800
800
800

640
640
640

445
445
445

940
940
940

474
474
474

279
279
279

369
369
369

614
614
614

90
78
78

218

GMC 60 Hz

Submersible pumps
with single channel impeller

Dimensions and weights

GMC4 100-150..60

13
78
83

d1 min.
33

d2
d3

85

100

222

116

DN2

538

285

HL
h1

383

DN2

hf

HL minimum submersible level

DN1
L2
L1

300
100

L3

250

200

L4

20

200

250

100

18

d4
131

h2

a1

225

a2

740 min

150

300

34

300

Version with foot and 90 elbow

TYPE
GMC4 100-150B-60
GMC4 100-150A-60

Version with duck foot coupling

EN 1092-2
PN 10

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

a1

a2

d1

d2

d3

L1

L2

L3

L4

kg

150

150

955

850

99

160 1177 235

305

990

846

566 1208 680

400

530

885

350

h2

219

d4

GMN 60 Hz

Submersible pumps
with channels impeller
Construction
Submersible pumps with channels impeller.
Twin mechanical seal with oil chamber.
Delivery connection DN 65-80-100-150-200-250-300.

Applications
Suitable to pump slurry, sewage and waste water (non-corrosive)
with solids in suspension.
For industrial and residential installations and general drainage
applications.
They are ideal for applications with smaller solids.
Solid passage from 30 to 140 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
Main materials

2-4-6 or 8 poles induction, 60Hz


Three-phase version: 380V 10%, up to 3,2 kW
380/660V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office

Pump casing: cast iron EN-GJL-250


Impeller: cast iron EN-GJL-250+Ni
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Shaft: stainless steel AISI 420B
Mechanical seal motor side: graphite/ceramic
Mechanical seal pump side: silicon carbide/silicon carbide

Coverage chart
100

GMN

50

60 Hz

40
30
GMN 30-80
20

GMN
40-100

H
m

GMN4
100-150

GMN 30-65
10

GMN4 GMN6
80-100 100-150

5
4

GMN4
100-250

GMN4
100-200

GMN4 30-80
GMN6
140-300
72.2003

3
2
10

m3/h

20

30

40

50

100

150

220

200

300

400 500

1000

1500 2000

3000

GMN 60 Hz

Submersible pumps
with channels impeller

Technical data
Power Supply

TYPE

GMN 30-65B-60
GMN 30-65A-60
GMN 30-80D-60
GMN 30-80C-60
GMN 30-80B-60
GMN 30-80A-60
GMN 40-100B-60
GMN 40-100A-60
GMN4 30-80A-60
GMN6 80-100B-60
GMN6 80-100A-60
GMN4 60-100B-60
GMN4 60-100A-60
GMN4 80-100B-60
GMN4 80-100A-60
GMN4 80-150C-60
GMN4 80-150B-60
GMN4 80-150A-60
GMN4 100-150B-60
GMN4 100-150A-60
GMN8 80-150A-60
GMN6 80-150B-60
GMN6 80-150A-60
GMN6 100-150C-60
GMN6 100-150B-60
GMN6 100-150A-60
GMN6 100-200C-60
GMN6 100-200B-60
GMN6 100-200A-60
GMN4 100-200A-60
GMN8 100-250B-60
GMN8 100-250A-60
GMN6 100-250C-60
GMN6 100-250B-60
GMN6 100-250A-60
GMN4 100-250B-60
GMN4 100-250A-60
GMN8 140-300A-60
GMN6 140-300A-60
P2 Rated power output

P2
kW
3,5
5,1
5,1
5,9
8,2
13,8
18,2
18,2
2,3
3,4
5,2
7,1
14,1
14,1
14,1
35,7
35,7
35,7
35,7
52,1
5,8
10,1
29
14,4
20,2
29
14,4
20,2
29
52,1
22
30
32
40
40
84,1
84,1
26,7
55,8

IN
A
7,5
11
11
13
15,5
29,5
34
34
5
8,5
12,5
13,5
30
30
30
65,5
65,5
65,5
65,5
92,5
14,5
21
57
29
40
57
29
40
57
92,5
46
60
60,5
80
80
147
147
59
108

IN Rated current

3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V

Starting

r.p.m.
.
3450
3450
3450
3450
3450
3450
3450
3450
1750
1150
1150
1750
1750
1750
1750
1750
1750
1750
1750
1750
850
1150
1150
1150
1150
1150
1150
1150
1150
1750
850
850
1150
1150
1150
1750
1750
850
1150
Standard

221

D.O.L.

D.O.L.

Free
passage

DN
mm
65
65
80
80
80
80
100
100
80
100
100
100
100
100
100
150
150
150
150
150
150
150
150
150
150
150
200
200
200
200
250
250
250
250
250
250
250
300
300

Thermal
protector

Humidity
probe

ATEX
Eex

mm
30
30
30
30
30
30
40
40
30
80
80
60
60
80
80
80
80
80
100
100
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
100
100
140
140

NO

NO

NO

NO

ATEX Eex Version on demand

34

GMN 60 Hz

Submersible pumps
with channels impeller

Characteristic curves
0
0

U.S. g.p.m.

200

Imp. g.p.m. 100

300

400

200

500

0 U.S. g.p.m.

400

300

30

200
100

Imp. g.p.m.

300

400

200

300

10

GMN 30-65..60

H
m

n = 3450 1/min

n = 1750 1/min

H
m

20

30

GMN4 30-80..60

80

ft

ft

20

B
5
40
10

10

0
0

m 3/h
Q l/min

50

100

1000

2000

80

m3/h
Q l/min

20

500

40

60
1000

80

0
100

1500

80

60

60

20

6
P2
kW

P2
kW
1

A
B

2
0
0

m 3/h
Q l/min

50

0,5
0

100

1000

20

0
0

2000

0
0

m3/h
Q l/min

20

500

40

60
1000

80

0 U.S. g.p.m.
0

Imp. g.p.m.

400
200

600

72.2019

800

400

600

50

50

U.S. g.p.m.

1000
800

GMN 40-100
n = 3450 1/min

ft

20

800
600

160

40

600
400

n = 3450 1/min

30

400

0 Imp. g.p.m. 200

150

GMN 30-80..60

A
40
H
m

100

1500

72.2020

120

30

ft

H
m

80

20

100

50
40
10

10

0
0

m3/h
Q l/min

50
1000

100

2000

150

3000

0
200

80

80

60

m3/h
Q l/min

100

50
1000

2000

150

3000

20

12

0
20
P2
kW

8
P2
kW
4

B
D
0
0

m3/h
Q l/min

50
1000

100

10

2000

0
250
4000

200

40

20

0
0

5
150

3000

200

0
0

m3/h
Q l/min

50
1000

100

2000

150

3000

200

250
4000
72.2021

72.2023

222

GMN 60 Hz

Submersible pumps
with channels impeller

Characteristic curves
0

U.S. g.p.m.

400

0 Imp. g.p.m. 200

600

800

0 U.S. g.p.m. 400

1000

600

400

800

1200

1600

800

1200

30

15

GMN6 80-100..60
H
m

800

400

Imp. g.p.m.

GMN4 60-100..60

H
m

40

n = 1150 1/min

80

n = 1750 1/min

ft

ft

20

10

60

30

40

20

10

20

10

0
0

m3/h
Q l/min

50
1000

100

150

2000

0
250
4000

200

3000

100
2000

200

300

4000

6000

0
400

60

40

20

20
0

12

P2
kW

10
P2
kW
6

2
1
0

m3/h
Q l/min

80

80

0
0

A
B

4
0
0

m3/h
Q l/min

50
1000

100

150

2000

3000

200

250
4000

0
0

m3/h
Q l/min

100
2000

200

300

4000

6000

72.2022

0 U.S. g.p.m. 400


0

Imp. g.p.m.

400

800

1200

72.2025

0 U.S. g.p.m. 400

1600

800

400

1200

Imp. g.p.m.

800

400

1200

1600

800

1200

15

30

GMN8 80-150..60

GMN4 80-100..60
H
m

H
m

80

n = 1750 1/min

40

n = 850 1/min

ft

ft
20

10

60

30

20

40
5

10

10

20

0
0

m3/h
Q l/min

100
2000

200

4000

300

6000

0
400

m3/h
Q l/min

100
2000

200

4000

300

6000

0
400

80

80

60

60

%
B

20

14

10
P2
kW

4
P2
kW
2

20

0
0

1
0
0

m3/h
Q l/min

100
2000

200

4000

300

6000

400

0
0

m3/h
Q l/min

100
2000

200

4000

300

6000

400
72.2025

72.2025

223

34

GMN 60 Hz

Submersible pumps
with channels impeller

Characteristic curves
0

U.S. g.p.m.

800

0 Imp. g.p.m. 200

1200

1600

2000

1200

800

1600

50

30

U.S. g.p.m.

800

1200

0 Imp. g.p.m. 400

GMN4 80-150..60
80

n = 1150 1/min

2000
1600
160

GMN6 80-150..60
H
m

1600
1200

800

n = 1750 1/min

40

ft

20
60

30

120

B
C

ft

H
m
40

20

20

10

80

10

40

0
0

m3/h
Q l/min

200

100
2000

300

4000

6000

0
500
8000

400

80

80

40

0
0

m3/h
Q l/min

200

100
2000

4000

300

6000

0
500
8000

400

A
B

40

20

20
0

26
P2
kW
20

40
P2
kW

20
10

10

0
0

m3/h
Q l/min

200

100
2000

300

4000

6000

400

500
8000

0
0

m3/h
Q l/min

200

100
2000

4000

300

6000

400

500
8000
72.2026

72.2022

0
0

U.S. g.p.m.

1000

Imp. g.p.m. 500

1500
1000

0 U.S. g.p.m.

2500

2000

2000

1500

Imp. g.p.m.

1000

2000

1000

3000
2000

30

GMN6 100-150..60

H
m

20

GMN4 100-150..60

40

80

n = 1150 1/min

n = 1750 1/min

H
m

A
B

30

ft

120

ft

80
20

40
10

40
10

0
0

m 3/h
Q l/min

200

300
5000

500

400

0
600
10000

20

50

12000

0
800

A
B

40
P2
kW
20

8
4

600

8000

20

16
P2
kW

400

20

200
4000

60

60

m3/h
Q l/min

80

100
80

0
0

10
0
0

m /h
Q l/min

0
200

300
5000

400

500

600
10000

0
0

m3/h
Q l/min

200
4000

400

8000

600

12000

800

72.2024

72.2029

224

GMN 60 Hz

Submersible pumps
with channels impeller

Characteristic curves
0

U.S. g.p.m.

1600

0 Imp. g.p.m. 800

2400

3200

4000

2400

1600

3200

U.S. g.p.m.

1600

0 Imp. g.p.m. 800

20

2400

3200

4000

2400

1600

3200

40

GMN6 100-200..60

15
H
m

GMN4 100-200..60

60

n = 1150 1/min

120

n = 1750 1/min

ft

30

ft

40

H
m

80

10

20

20

40

10

0
0

m3/h
Q l/min

200
4000

400

8000

600

12000

0
1000
16000

800

100

80

80

40

C
0
0

m /h
Q l/min

200
4000

400

8000

600

0
1000
16000

800

12000

50
P2
kW
40

600

55

8000

25
20
P2
kW
10

400

200
4000

20

m3/h
Q l/min

40

20

0
0

35
12000

800

30

1000
16000

0
0

m3/h
Q l/min

400

200
4000

8000

600

800

12000

1000
16000

72.2028

0 U.S. g.p.m. 1200

20

1200

Imp. g.p.m.

2400

3200
2400

72.2028

4800

3200

U.S. g.p.m.

2000

0 Imp. g.p.m. 200

3000
2000

4000

5000

3000

4000

30

GMN8 100-250..60

60

GMN6 100-250..60

n = 850 1/min

H
m

ft

15

80

n = 1150 1/min

ft

20

H
m

40

60

10

40

10

20
5

20

0
0

m3/h
Q l/min

300
5000

600
10000

0
1200
20000

900
15000

100

m3/h
Q l/min

250
5000

500

10000

750

15000

0
1250
20000

1000

100
80

80
60

40

20

20

40

40
P2
kW

P2
kW
20

A
C

10
0
0

m3/h
Q l/min

300
5000

600
10000

900
15000

1200
20000

20

10
0

0
0

0
0

m3/h
Q l/min

250
5000

500

10000

750

15000

1000

1250
20000
72.2022

72.2025

225

34

GMN 60 Hz

Submersible pumps
with channels impeller

Characteristic curves
0
50

U.S. g.p.m.

800

0 Imp. g.p.m. 400

1200

1600

2000

1200

800

3200

4800
3200

6400

8000

4800

6500

20

160

GMN4 100-250..60

GMN8 140-300..60

n = 1750 1/min

n = 850 1/min

40

U.S. g.p.m.

0 Imp. g.p.m.1600

1600

120

15

30

ft

H
m

H
m

80

10

40

60

ft

A
40

20
20
10

0
0

m3/h
Q l/min 5000

500
10000

1000
15000

0
1500
25000

20000

80

80

40

1000
16000

0
2000
32000

1500
24000

20

0
35

100
P2
kW

30
P2
kW
20

60

40

15
0
0

m /h
Q l/min 5000

500
10000

1000
15000

10

1500
25000

20000

U.S. g.p.m.

3200

0 Imp. g.p.m.1600

4800
3200

6400
4800

8000
6500

20

GMN6 140-300..60

60

n = 1150 1/min
15

ft

H
m

40

10

20
5

0
0

m3/h
Q l/min

500
8000

1000
16000

1500
24000

0
2000
32000

100
80

%
40
20
0
60
50
P2
kW
30

20
0
0

m3/h
Q l/min

500
8000

1000
16000

1500
24000

0
0

m3/h
Q l/min

500
8000

1000
16000

1500
24000

2000
32000
72.2028

72.2033

10

500
8000

40

20

m3/h
Q l/min

100

100

20

0
0

2000
32000
72.2028

226

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN 30-65..60

78
83

d1 min.
d2

33

85
d3

100

180

117

185

253

DN2
HL

216

DN2

hf

h1
HL minimum submersible level

DN1
L2

92

200
92

120

198

L1

L4
18

L3

d4
180

h2

a1

140

a2

360 min

62

170

34

194

Version with duck foot coupling

Version with foot and 90 elbow

TYPE

EN 1092-2
PN 10

GMN 30-65B-60
GMN 30-65A-60

DN1
80
80

DN2
65
65

Dimensions
mm
f
456
515

HL
300
330

hf
78
78

h1
90
90

h2
596
655

a1
133
133

227

a2
145
145

d1
625
625

Weight
d2
495
495

d3
357
357

d4
767
774

L1
358
365

L2
220
220

L3
289
333

L4
458
510

kg
58
70

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights

GMN 30-80..60
GMN4 30-80..60

13

d1 min.

78
83

d2
33

85

d3

100

180

116

DN2

DN2

370
256

200

HL

hf
h1
HL minimum submersible level

DN1
L2

250
20
160

L4

100

160

210

100

L3

210

L1

18
d4
131

h2

a1

140

a2

412 min

75

185

185

Version with duck foot coupling

Version with foot and 90 elbow

EN 1092-2
PN 10

TYPE
GMN
GMN
GMN
GMN
GMN4

30-80D-60
30-80C-60
30-80B-60
30-80A-60
30-80A-60

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

h2

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

kg

80

80

515

330

110

90

655

133

145

700

511

366

791

365

220

293

475

77

80
80
80

80
80
80

767
805
448

438
485
316

132
132
110

68
68
90

917
955
588

165
165
133

165
165
145

700
700
700

571
571
524

386
386
386

850
850
804

405
405
358

220
220
220

293
293
293

515
515
468

190
190
79

228

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN 40-100..60
GMN6 80-100..60
GMN4 60-100..60
GMN4 80-100..60

78
33

83

d1 min.
100

d2
d3

85

220

190

116

GMN4 80-100A-C

DN2

GMN
GMN 50-100
40-100 GMN4 80-100D
GMN6 80-100

HL minimum submersible level

DN1

hf

266

220

h1

400

HL

DN2

L2
L1

L4

250
100

100

20
160
210

210
160

L3

18
d4
131

100

a1

150

a2

250

250

GMN
GMN
GMN6
GMN6
GMN4
GMN4
GMN4
GMN4

EN 1092-2
PN 10
40-100B-60
40-100A-60
80-100B-60
80-100A-60
60-100B-60
60-100A-60
80-100B-60
80-100A-60

34

Version with duck foot coupling

Version with foot and 90 elbow

TYPE

550 min

h2

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

h2

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

kg

125

100

814

480

127

73

964

168

184

750

628

441

928

462

275

365

602

200

125
125
125
125

100
100
100
100

597
808
808
890

424
526
526
570

62
54
54
54

138 747
147 958
147 958
147 1040

180
189
189
189

231
212
212
212

850
800
800
800

673
640
640
640

466
445
445
445

973
940
940
940

507
474
474
474

300
279
279
279

390
369
369
369

647
614
614
614

111
160
160
200

125

100

890

570

54

147 1040 189

212

800

640

445

940

474

279

369

614

200

229

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN8 80-150..60
GMN6 100-150..60
GMN4 80-150..60
GMN4 100-150..60

78
83

d1 min.
33

d2
d3

85

100

222

116

DN2

GMN6
80-150

538

285

HL
h1
GMN6
100-150
GMN4
80-150
GMN4
100-150

383

DN2

hf

HL minimum submersible level

DN1
L2
L1

100

300
100

20

250

200

L3

200

250

L4

18

d4
131

150

a1

225

a2

300

300

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMN8 80-150A-60
GMN6 80-150B-60
GMN6 80-150A-60
GMN6 100-150C-60
GMN6 100-150B-60
GMN6 100-150A-60
GMN4 80-150C-60
GMN4 80-150B-60
GMN4 80-150A-60
GMN4 100-150B-60
GMN4 100-150A-60

740 min

h2

EN 1092-2
PN 10

Dimensions
mm

Weight

DN1
150
150
150

DN2
150
150
150

f
902
902
955

HL
580
580
574

hf
113
113
100

h1
h2
a1
147 1127 191
147 1127 191
160 1180 235

a2
223
223
305

d1
850
850
990

d2
673
673
846

d3
d4
L1
467 1038 507
467 1038 507
566 1208 680

L2
301
301
400

L3
431
431
530

L4
712
712
885

kg
280
280
341

150

150

955

574

100

160 1180 235

305

990

846

566 1208 680

400

530

885

341

150

150

955

574

100

160 1180 235

305

990

846

566 1208 680

400

530

885

330

150
150

150
150

955 574
1642 810

100
83

160 1180 235


177 1864 287

305 990 846


309 1050 962

566 1208 680


568 1224 709

400
400

530
530

885
914

328
675

230

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN4 100-200..60
GMN6 100-200..60

78
33

83

d1 min.
100

d2
d3

85

337
f

DN2

HL

h1

461

700

DN2
340

116

HL minimum submersible level

DN1

hf

L2
L1
400
133

300

250

20

250

300

133

20
d4
110

a1

265

a2

800 min

h2

350

34

350

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMN4 100-200A-60
GMN6 100-200C-60
GMN6 100-200B-60
GMN6 100-200A-60

EN 1092-2
PN 10

Dimensions
mm

DN1
200

DN2
f
HL
200 1613 780

hf
153

h1
h2
a1
198 1878 306

a2
d1
d2
335 1200 962

d3
d4
L1
656 1469 786

L2
480

L3
-

L4
-

Weight
kg
665

200

200

990

625

139

211 1254 269

335 1200 958

656 1466 782

480

471

200

200

1110 670

139

211 1326 269

335 1200 958

656 1466 782

480

462

231

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights


11

11
d1 min.

19

GMN4 100-250..60
GMN6 100-250..60
GMN8 100-250..60

d2
d3

120

125

437
f

DN 300

827

h1

665

HL

DN2
395

119

HL minimum submersible level

DN1

hf

L2
L1
650

500

30

500
795
d4
113

a1

265

a2

1000 min

h2

350

350

Version with duck foot coupling

Version with foot and 90 elbow

TYPE
GMN4 100-250B-60
GMN4 100-250A-60
GMN6 100-250C-60
GMN6 100-250B-60
GMN6 100-250A-60
GMN8 100-250B-60
GMN8 100-250A-60

EN 1092-2
PN 10

Dimensions
mm
f

HL

L1

L2

L3

L4

kg

214 1975 336

419 1400 1167 789 1843 978

600

914

286

214 1894 336

419 1400 1167 789 1843 978

600

730

286

214 1256 336

419 1400 1167 789 1843 978

600

550

hf

DN1

DN2

250

250

1710 835

286

250

250

1629 800

250

250

992

660

Weight

h1

h2

232

a1

a2

d1

d2

d3

d4

GMN 60 Hz

Submersible pumps
with channels impeller

Dimensions and weights


103

11

11
d1 min.

19

GMN8 140-300..60
GMN6 140-300..60

d2

125

d3

120

437

119

DN 300
f

DN2

827

h1

665

445

HL

HL minimum submersible level

DN1

hf

L2
L1
650

500

30

500
795

d4
h2

540

a1

624

a2

1000 min

113

624

34
Version with duck foot coupling

Version with foot and 90 elbow

TYPE

EN 1092-2
PN 10

GMN8 140-300A-60
GMN6 140-300A-60

DN1
350
350

DN2
f
HL
hf
300 1959 1127 260
300 2040 1164 260

Dimensions
mm
h1
h2
a1
494 2271 465
494 2352 465

233

a2
d1
d2
d3
d4
L1
L2
465 1500 1254 789 1930 1065 600
465 1500 1254 789 1930 1065 600

Weight
L3
-

L4
-

kg
980
1200

GMG 60 Hz

Submersible pumps
with high power grinder
Construction
Submersible pumps with high power grinder.
Twin mechanical seal with oil chamber (lip-seal motor side up
to 1,6 kW).
Delivery connection DN 40.

Applications
Suitable for pumping waste water containing long filamentous,
Paper and textile materials and organics.
They are particularly suitable for use in domestic, residential and
industrial installations
Solid passage from 6 and 7 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 poles induction, 60Hz
Single-phase version: 220V 10%, with float switch and control
box with thermal protection and starting capacitors.
Three-phase version: 380V 10%, up to 3,2 kW
380/660V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office

Main materials
Pump casing: cast iron EN-GJL-250
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Impeller: cast iron GS 400
Shaft : stainless steel AISI 420B
Lip seal made of nitrile up to 1,6 kW
Mechanical seal motor side: graphite/ceramic to 1,6 kW
Mechanical seal pump side: silicon carbide/silicon carbide

Coverage chart
U.S. g.p.m.

20

30

50

40

60

70

80

50
160

GMG 7-40A

GMG
60 Hz

GMG 7-40B

40

GMG 7-40C

120

GMG 7-40D
ft

30

GMG 7-40E

H
m

GMG 6-40A

20

GMG 6-40B

80

GMG 6-4
0C
GMG 6-4
0D

40

GMG 6-40E

10

0
0

m 3/h
l/min

10

5
100

15
200

20
300
72.2004

234

GMG 60 Hz

Submersible pumps
with high power grinder

Technical data
Power Supply

TYPE

GMGM 6-40E-60
GMG 6-40E-60
GMGM 6-40D-60
GMG 6-40D-60
GMGM 6-40C-60
GMG 6-40C-60
GMGM 6-40B-60
GMG 6-40B-60
GMGM 6-40A-60
GMG 6-40A-60
GMG 7-40E-60
GMG 7-40D-60
GMG 7-40C-60
GMG 7-40B-60
GMG 7-40A-60
P2 Rated power output

P2
kW
0,78
0,95
1,1
1,4
1,1
1,4
1,8
2,4
1,8
2,4
3,2
3,2
5,1
5,1
5,1

IN
A
5,5
2,5
7,5
3,5
7,5
3,5
10
5
10
5
6,5
6,5
11
11
11

IN Rated current

1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V

Starting

r.p.m.
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
3450
Standard

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40

Thermal
protector

Humidity
probe

ATEX
Eex

mm
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7

NO
NO
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO

ATEX Eex Version on demand

34

235

GMG 60 Hz

Submersible pumps
with high power grinder

Characteristic curves
0
0

U.S. g.p.m.
Imp. g.p.m.

30
20

50

40

40

30

60

70

50

60

U.S. g.p.m.
Imp. g.p.m.

30

50

40

20

40

30

60

70

50

60

50

30

160

GMG 6-40..60

H
m

n = 3450 1/min

A
B

GMG 7-40..60
n = 3450 1/min

80

20
ft

140

40

ft

H
m

120

D
100

30

40

80

10

20
60

40
0

0
0

m3/h
Q l/min

100

10

15

200

10

50

40

40

30

%
20

10

2,0

0,5
0

0
0

m /h
Q l/min
3

100

10

200

10

100

200

15

A B

10

0
5

A
B

P2
kW
1,0

m3/h
Q l/min

A
B

0
0

A
B
C
D
E

4
P2
kW
2

1
0

15
72.2035

0
0

m3/h
Q l/min

100

10

200

15
72.2036

236

GMG 60 Hz

Submersible pumps
with high power grinder

Dimensions and weights

GMGM 6-40..60
GMG 6-40..60
GMG 7-40..60

52
12

86

d1 min.
d2
d3

3/4

f
40

75

HL

28

h1

G 2

176

L1

134

HL minimum submersible level

L2

hf

L4

a1
a2

1/

R6

16

110
136

400 min

d4

100

90

L3

Version with duck foot coupling

Version with threaded flange and 90 elbow

Dimensions
mm
1

HL

hf

h1

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

Weight
kg

40

460

240

71

63

112

112

450

312

194

392

268

150

212

262

40

40

458

315

10

124

121

121

450

327

189

413

288

150

230

405

45

40

517

336

10

124

121

121

450

334

189

420

295

150

230

412

60

TYPE
GMGM 6-40E-60
GMG 6-40E-60
GMGM 6-40D-60
GMG 6-40D-60
GMGM 6-40C-60
GMG 6-40C-60
GMGM 6-40B-60
GMG 6-40B-60
GMGM 6-40A-60
GMG 6-40A-60
GMG 7-40E-60
GMG 7-40D-60
GMG 7-40C-60
GMG 7-40B-60
GMG 7-40A-60

237

34

I-GM 60 Hz

AISI 316

Submersible pumps

Construction
Submersible pumps in AISI 316 stainless steel.
I-GMV with free-flow (vortex) impeller
I-GMC with single-channel impeller
I-GMN with channels impeller
Twin mechanical seal with oil chamber (lip-seal motor side up to
2,4 kW 2 poles).
Delivery connection DN 50-65-80-100-150

Applications
Suitable to pump aggressive and corrosive liquids, particularly
to drain waste water in industrial and chemical process plants.
Solid passage from 30 to 100 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor

Main materials

2 or 4 poles induction, 60Hz


Three-phase version: 380V 10%, up to 3,2 kW
380/660V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office

Pump casing: stainless steel AISI 316


Motor casing: stainless steel AISI 316
Motor cover: stainless steel AISI 316
Impeller: stainless steel AISI 316
Shaft: stainless steel AISI 316L
Screws: stainless steel AISI 316
Mechanical seal motor side: graphite/ceramic/FPM (lip-seal made of nitrile up to
2,4 kW 2 poles).
Mechanical seal pump side: silicon carbide/silicon carbide/FPM

Coverage chart
100

I-GM

50

60 Hz

40
30
20

I-GMN

H
m
10

I-GMN4

I-GMV
5
4

I-GMV4
72.2006

3
2
2

Q m3/h

10

15

20

30

238

40

50

100

150

200

300

400 500

I-GM 60 Hz

Submersible pumps

AISI 316

Technical data
Power Supply

TYPE

I-GMVM
I-GMV
I-GMVM
I-GMV
I-GMVM
I-GMV
I-GMV4M
I-GMV4
I-GMV4M
I-GMV4
I-GMV4
I-GMN
I-GMN
I-GMN
I-GMN
I-GMN
I-GMN
I-GMN4
I-GMN4
I-GMN6
I-GMN4

50-50C-60
50-50C-60
50-50B-60
50-50B-60
50-50A-60
50-50A-60
50-65B-60
50-65B-60
50-65A-60
50-65A-60
50-80A-60
30-65B-60
30-65A-60
30-80B-60
30-80A-60
40-100B-60
40-100A-60
60-100A-60
80-100A-60
100-150A-60
100-150A-60

P2 Rated power output

P2
kW
1,8
2,4
1,8
2,4
2,6
2,9
1,2
1,3
1,2
1,3
2,9
3,5
5,1
5,1
5,9
18,2
18,2
7,1
12,1
14,4
35,7

IN
A
10
5
10
5
16
6
8,5
3,5
8,5
3,5
6,5
7,5
11
11
13
34
34
13,5
27
29
65,5

IN Rated current

1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V
3~ 380/660V

Starting

r.p.m.
3450
3450
3450
3450
3450
3450
1750
1750
1750
1750
1750
3450
3450
3450
3450
3450
3450
1750
1750
1150
1750
Standard

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
50
50
50
50
50
50
65
65
65
65
80
65
65
80
80
100
100
100
100
150
150

Thermal
protector

Humidity
probe

ATEX
Eex

mm
50
50
50
50
50
50
50
50
50
50
50
30
30
30
30
40
40
60
80
100
100

NO
NO
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO

ATEX Eex Version on demand

34

239

I-GM 60 Hz

Submersible pumps

AISI 316

Characteristic curves
0 U.S. g.p.m. 50

100
50

0 Imp. g.p.m.

150

0 U.S. g.p.m. 50

200
150

100

0 Imp. g.p.m.

100
50

150

200
150

100

10

20
60

I-GMV 50-50..60
n = 3450 1/min

I-GMV4 50-65..60

n = 1750 1/min

ft

15

H
m

H
m

40

B
10

30

ft

20

4
20

10

5
2
1
0

0 Q m3/h
l/min
0

10

250

30
500

20

40

750

50

30

20

30
500

40

750

50

10

20

1,5

P2
2
kW

B
C
0 Q m3/h
l/min
0

10

250

40

750

50
72.2039

0 U.S. g.p.m. 100


0 Imp. g.p.m.

200

100

300
200

400
300

30

I-GMV4 50-80..60

n = 1750 1/min
ft

H
m
20

6
5
4

10

3
2
1
0 Q m3/h
l/min
0

20

500

40

60
1000

80

1500

0
100

60
40

20
0
3

P2
2
kW
1
0 Q m3/h
l/min
0

20

500

40

60
1000

80

1500

0 Q m3/h
l/min
0

10

250

20

30
500

40

750

50
72.2039

10
9

A
B

0,5
30
500

20

P2
1
kW

250

40

10

60

40

0 Q m3/h
l/min
0

100
72.2039

240

I-GM 60 Hz

AISI 316

Submersible pumps

Characteristic curves
0

U.S. g.p.m.

200

0 Imp. g.p.m. 100

300

500

400

200

300

U.S. g.p.m.

25

I-GMN 30-65..60
n = 3450 1/min

20

300

400

200

500

300

400

30

80

200

0 Imp. g.p.m. 100

400

25

20

I-GMN 30-80..60
n = 3450 1/min

80

60

B
15

ft

H
m

40

60

H
m
15

ft
40

10
10
20
5

0 Q m 3/h
l/min
0

25
500

50

75

1000

1500

0
125
2000

100

80

0 Q m 3/h
l/min
0

50

25
500

75

1000

1500

0
125
2000

100

80

60
%
40

60

40

20

20

P2
4
kW

P2
4
kW

A
B

2
0

20

0 Q m 3/h
l/min
0

25
500

50

75

1000

1500

100

A
B

2
0

125
2000

0 Q m 3/h
l/min
0

50

25
500

75

1000

1500

100

125
2000

72.2042

U.S. g.p.m.

0 Imp. g.p.m. 200

400

600
400

800

72.2042

1000

600

800

U.S. g.p.m.

400

0 Imp. g.p.m. 200

600
400

1000

800
600

800

50

20

I-GMN4 60-100..60

160

60

n = 1750 1/min

15

ft

H
m

40

I-GMN 40-100..60

n = 3450 1/min

40

10

120

30

ft

H
m

80

20
20
5

40
10

0 Q m 3/h
l/min
0

50
1000

100

2000

150

3000

200

0
250
4000

80

50
1000

100

2000

150

3000

0
250
4000

200

80

60

60

40

40

20

20

20

P2
6
kW

P2
15
kW

4
2

0 Q m3/h
l/min
0

10
0 Q m 3/h
l/min
0

50
1000

100

2000

150

3000

200

250
4000
72.2045

0 Q m3/h
l/min
0

50
1000

100

2000

150

3000

200

250
4000
72.2043

241

34

I-GM 60 Hz

AISI 316

Submersible pumps

Characteristic curves
0 U.S. g.p.m.
0 Imp. g.p.m.

400

800

600

400

1000

1200

800

600

1000

1200

25

U.S. g.p.m.

0 Imp. g.p.m. 400

1200
800

25

80

1600

2000

1200

1600
80

I-GMN4 80-100...60

I-GMN6 100-150...60

n = 1750 1/min

20

800

n = 1150 1/min

20

60

60

A
15
H
m

ft

15

ft

40

H
m

40

10

10

20

20

0 Q m 3/h
l/min 1000
0

200
3000

100
2000

0
340

300
5000

4000

80

80

60
%
40

0
15

P2
8
kW

6000

400

0
500
8000

5
0 Q m /h
l/min 1000
0

200
3000

100
2000

300
5000

4000

340
72.2046

0
0

U.S. g.p.m.
Imp. g.p.m.

800

1200
800

1600
1200

2000
1600

2000

n = 2850 1/min

30

120

100
ft

H
m

80

20

60
ft
40

10
20

0
0

m3/h
Q l/min 100
2000

200

400

300
4000

6000

60

500
8000

0
600
10000

40
20
0

40
P2
30
kW

20
0
0

m3/h
Q l/min 100
2000

200

400

300
4000

6000

500
8000

0 Q m3/h
l/min
0

100
2000

200

4000

300

6000

400

500
8000
72.2047

2400

I-GMN4 100-150..60

10

300

P2
10
kW

80

4000

20

12

200

40

40

100
2000

60

20

0 Q m3/h
l/min
0

600
10000
72.2040

242

I-GM 60 Hz

Submersible pumps

AISI 316

Dimensions and weights

I-GMVM 50-50..60
I-GMV 50-50..60

52
12

86

450 min.
312
194

544

3/4

330

50
125

75

28

G 2
176

HL minimum submersible level

268

134

55
150

132
100

13

110

403

156

252

16

136

Version with duck foot coupling

Version with threaded flange and 90 elbow

Weight

TYPE
I-GMVM
I-GMV
I-GMVM
I-GMV
I-GMVM
I-GMV

kg
50-50C-60
50-50C-60
50-50B-60
50-50B-60
50-50A-60
50-50A-60

40

243

400 min

50

90

112 112

392

34

I-GM 60 Hz

AISI 316

Submersible pumps

Dimensions and weights

I-GMV4M 50-65..60
I-GMV4 50-65..60
13
78
83

600 min
447

33

85

317

100

180

117

DN 65

121

335

60

47

567

253

EN 1092-2
PN 10

200
HL minimum submersible level

50

92

92

180
198
120

310

18
451
720

283

2
1/

130 130

69

15

96

90

15

Version with threaded flange and 90 elbow

Weight

TYPE
I-GMV4M
I-GMV4
I-GMV4M
I-GMV4

Version with duck foot coupling

kg
50-65B-60
50-65B-60
50-65A-60
50-65A-60

47

244

360 min.

181

I-GM 60 Hz

AISI 316

Submersible pumps

Dimensions and weights

GMN 30-65..60
13
78
83

d1 min.
d2

33

85
d3

100

180

117

185

253

DN2
HL

216

DN2

hf

h1
HL minimum submersible level

DN1
L2

92

200
92

120

198

L1

L4
18

L3

d4
180

h2

a1

140

a2

360 min

62

170

194

Version with threaded flange and 90 elbow

TYPE

EN 1092-2
PN 10

I-GMN 30-65B-60
I-GMN 30-65A-60

DN1
80
80

DN2
65
65

Version with duck foot coupling

Dimensions
mm
f
456
515

HL
300
330

hf
78
78

h1
90
90

h2
596
655

a1
133
133

245

a2
145
145

d1
625
625

Weight
d2
495
495

d3
357
357

d4
767
774

L1
358
365

L2
220
220

L3
289
333

L4
458
510

kg
60
79

34

I-GM 60 Hz

AISI 316

Submersible pumps

Dimensions and weights

I-GMV4 50-80-60
I-GMN 30-80-60

13

d1 min.

78
83

d2
33

85

d3

100

180

116

DN 80

EN 1092-2
PN 10

370
256

DN 80

EN 1092-2
PN 10

200

HL

hf
h1
DN 80

EN 1092-2
PN 10

250

L2

100

100
L1

20

L3

210

160

L4

160

210

HL minimum submersible level

18
d4
131

h2

a2

140

a1

412 min

80

185

185

Version with threaded flange and 90 elbow

TYPE
I-GMV4 50-80A-60
I-GMN 30-80B-60
I-GMN 30-80A-60

Version with duck foot coupling

EN 1092-2
PN 10

Dimensions
mm

Weight
kg

DN1
80

DN2
80

f
519

HL
363

hf
84

h1
116

h2
659

a1
136

a2
157

d1
658

d2
511

d3
366

d4
791

L1
365

L2
220

L3
355

L4
544

67

80

80

515

330

110

90

655

133

145

700

511

366

791

365

220

355

544

79

246

I-GM 60 Hz

AISI 316

Submersible pumps

Dimensions and weights

I-GMN 40-100..60
I-GMN4 60-100..60
I-GMN4 80-100..60

13
78
83

d1 min.
33

d2
d3

85

100

190

116

HL minimum submersible level

DN1

I-GMN4
60-100
80-100

hf

266

h1

400

L2
L1
250
100

100

L4
210
160

L3

20
160
210

220

I-GMN
40-100

DN2

HL

DN2

18
d4
131
100

a1

150

a2

550 min

h2

250

34

250

Version with threaded flange and 90 elbow

TYPE
I-GMN 40-100B-60
I-GMN 40-100A-60
I-GMN4 60-100A-60
I-GMN4 80-100A-60

Version with duck foot coupling

EN 1092-2
PN 10

Dimensions
mm

Weight

DN1

DN2

HL

hf

h1

h2

a1

a2

d1

d2

d3

d4

L1

L2

L3

L4

kg

125

100

814

478

127

73

964

168

184

750

628

441

928

467

280

449

694

210

125
125

100
100

826
890

526
570

54
53

147 976 189


147 1040 189

212
212

800
800

640
640

445
445

940
940

474
474

279
279

456
453

706
706

167
220

247

I-GM 60 Hz

AISI 316

Submersible pumps

Dimensions and weights

I-GMN4 100-150..60
I-GMN6 100-150..60

13
78
83

d1 min.
33

d2
d3

85

100

222

116

DN2

538

285

HL
h1

383

DN2

hf

HL minimum
submersible
level

DN1
L2
L1

200

200

250

20

250

300
100

100

18

d4

h2

a1

225

a2

740 min

131

300

300

Version with threaded flange and 90 elbow

TYPE

EN 1092-2
PN 10

I-GMN6 100-150A-60
I-GMN4 100-150A-60

DN1
150
150

DN2
f
HL
150 991 576
150 1071 574

Version with duck foot coupling

Dimensioni - Dimensions
mm
hf
100
100

h1
h2
a1
160 1180 235
160 1180 235

248

a2
305
305

d1
990
990

d2
931
931

d3
d4
L1
566 1208 680
566 1208 680

Weight
L2
400
400

L3
-

L4
-

kg
368
328

B-GM 60 Hz

Submersible pumps

B 10

Construction
Submersible pumps, B 10 bronze marine version.
B-GMV with free-flow (vortex) impeller
B-GMC with single-channel impeller
B-GMN with channels impeller
Twin mechanical seal with oil chamber (lip-seal motor side up to
2,4 kW 2 poles).
Delivery connection DN 50-65-80

Applications
Suitable to pump industrial waste water in chemical, and process
industries, agricultural and marine areas.
Solid passage from 30 to 50 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor

Main materials

2 or 4 poles induction, 60Hz


Three-phase version: 380V 10%, up to 3,2 kW
380/660V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office

Pump casing, Motor casing, Motor cover: B 10 bronze marine


Impeller: stainless steel AISI 316
Motor shaft: stainless steel AISI 316L
Screws: stainless steel AISI 316
Mechanical seal motor side: graphite/ceramic/FPM (lip-seal made of nitrile up to
2,4 kW 2 poles).
Mechanical seal pump side: silicon carbide/silicon carbide/FPM

Coverage chart
30

B-GM
60 Hz

20

H
m

34

B-GMN
10

B-GMV

B-GMV4

72.2005

2
2

Q m3/h

10

15

249

20

30

40

50

100 120

B-GM 60 Hz

Submersible pumps

B 10

Technical data
Power Supply

TYPE

B-GMVM
B-GMV
B-GMVM
B-GMV
B-GMVM
B-GMV
B-GMVM
B-GMV
B-GMV4M
B-GMV4
B-GMV4M
B-GMV4
B-GMV4
B-GMC
B-GMN
B-GMN
B-GMN
B-GMN

30A-60
30A-60
50-50C-60
50-50C-60
50-50B-60
50-50B-60
50-50A-60
50-50A-60
50-65B-60
50-65B-60
50-65A-60
50-65A-60
50-80A-60
40-65A-60
30-65B-60
30-65A-60
30-80B-60
30-80A-60

P2 Rated power output

P2
kW
0,5
0,5
1,8
2,4
1,8
2,4
2,6
2,9
1,2
1,3
1,2
1,3
2,9
2,9
3,5
5,1
5,1
5,9

IN
A
4
1,5
10
5
10
5
16
6
8,5
3,5
8,5
3,5
6,5
6
7,5
11
11
13

IN Rated current

1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
1~ 220V
3~ 380V
3~ 380V
3~ 380V
3~ 380V
3~ 380/660V
3~ 380/660V
3~ 380/660V

Starting

r.p.m.
3450
3450
3450
3450
3450
3450
3450
3450
1750
1750
1750
1750
1750
3450
3450
3450
3450
3450
Standard

250

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
1 1/4
1 1/4
50
50
50
50
50
50
65
65
65
65
80
65
65
65
80
80

Thermal
protector

Humidity
probe

ATEX
Eex

mm
30
30
50
50
50
50
50
50
50
50
50
50
50
40
30
30
30
30

NO
NO
NO
NO
NO
NO
NO
NO
NO

ATEX Eex Version on demand

NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO

B-GM 60 Hz

B 10

Submersible pumps

Characteristic curves
0 U.S. g.p.m. 15
0 Imp. g.p.m.

30
15

45

0 U.S. g.p.m. 50

60
45

30

10

100
50

0 Imp. g.p.m.

150

200
150

100

20

B-GMV 30..60

n = 1750 1/min

30

n = 3450 1/min
ft

15

20

H
m

H
m
6

60

B-GMV 50-50..60

ft

A
40

10

4
10

20
5

2
1
0

0 Q m 3/h
l/min
0

3
50

9
150

6
100

0 Q m 3/h
l/min
0

10

250

30
500

20

40

750

10

10

0,6

P2
0,4
kW

P2
2
kW

0,2

A
B
C

1
0 Q m 3/h
l/min
0

3
50

9
150

6
100

12
200

15
250

0 Q m 3/h
l/min
0

10

250

30
500

20

40

750

72.2039

0 U.S. g.p.m. 50
0 Imp. g.p.m.

100
50

150

0 U.S. g.p.m. 100

200
150

100

50
72.2039

0 Imp. g.p.m.

10

200

100

300
200

400
300

10
30

B-GMV4 50-65..60

H
m
6

ft

20

ft

4
10

1
20

30
500

40

750

50

60

10

250

20

6
5

10

n = 1750 1/min

H
m

0 Q m 3/h
l/min
0

30

B-GMV4 50-80..60

n = 1750 1/min

34
0 Q m 3/h
l/min
0

20

500

40

60
1000

80

1500

0
100

60
40

40

%
A

20

20

1,5

P2
1
kW

P2
2
kW

0,5
0

30

20

50

40

30

0
15
250

12
200

1
0 Q m 3/h
l/min
0

10

250

20

30
500

40

750

50

72.2039

0 Q m 3/h
l/min
0

20

500

40

60
1000

80

1500

100
72.2039

251

B-GM 60 Hz

Submersible pumps

B 10

Characteristic curves
0

U.S. g.p.m.

100

150

0 Imp. g.p.m. 50

250

200

100

150

200

25

80

B-GMC 40-65..60
n = 3450 1/min

20

60
ft

15

H
m

40

10

20
5

0 Q m 3/h 10
l/min
0

250

20

30
500

40

750

50

0
60
1000

50

0
60
1000

60

%
40

A
20
0
3

P2
2
kW
1
0

0 Q m 3/h 10
l/min
0

250

20

30
500

40

750

72.2042

U.S. g.p.m.

0 Imp. g.p.m. 100

200

300

400

500

300

200

400

U.S. g.p.m.

0 Imp. g.p.m. 100

25

B-GMN 30-65..60
n = 3450 1/min

20

300

400

500

300

200

400

30

80

200

25

20

B-GMN 30-80..60
n = 3450 1/min

80

60

B
15

ft

H
m

40

60

H
m
15

ft
40

10
10
20
5

0 Q m 3/h
l/min
0

25
500

50

1000

75

1500

0
125
2000

100

80

0 Q m 3/h
l/min
0

25
500

50

1000

75

1500

0
125
2000

100

80

60
%
40

60

40

20

20

P2
4
kW

P2
4
kW

A
B

2
0

20

0 Q m 3/h
l/min
0

25
500

50

1000

75

1500

100

A
B

2
0

125
2000
72.2042

0 Q m 3/h
l/min
0

25
500

50

1000

75

1500

100

125
2000
72.2042

252

B-GM 60 Hz

B 10

Submersible pumps

Dimensions and weights

202

346

B-GMV 30..-60

B-GMVM 30A-60
B-GMV 30A-60

56

Weight
kg

TYPE

1"1/4

14

90

100

134

B-GMV 50-50
Weight

TYPE

kg

B-GMVM
B-GMV
B-GMVM
B-GMV
B-GMVM
B-GMV

50-50C-60
50-50C-60
50-50B-60
50-50B-60
50-50A-60
50-50A-60

52
12

86

450 min.
312
194

40

3/4

75

176

125

134

544

G 2

330

50

28

HL minimum submersible level

55
150

13

34

132
100

268

110

403

156

252

16

136

Version with threaded flange and 90 elbow

Version with duck foot coupling

253

400 min

50

90

112 112

392

B-GM 60 Hz

B 10

Submersible pumps

Dimensions and weights

B-GMV4M 50-65..60
B-GMV4 50-65..60
13
78
83

600 min
447

33

85

317

100

180

117

DN 65

121

335

60

47

556

253

EN 1092-2
PN 10

200
HL minimum submersible level

50

92

92

180
198
120

310

18
451
720

283

1/

130 130

69

15

96

90

15

Version with duck foot coupling

Version with threaded flange and 90 elbow

Weight

TYPE
B-GMV4M
B-GMV4
B-GMV4M
B-GMV4

kg
50-65B-60
50-65B-60
50-65A-60
50-65A-60

40

254

360 min.

181

B-GM 60 Hz

B 10

Submersible pumps

Dimensions and weights


13

B-GMN 30-65..60

78
83

625 min.
495

33

85
357

100

180

117

DN 65

300

253
216

DN 65

EN 1092-2
PN 10

456

EN 1092-2
PN 10

90

78
HL minimum submersible level

DN 80

EN 1092-2
PN 10

92

220

200
92

120

198

358

501

18

333

767
184

360 min

140

145

133

595

60

170

34

194

Version with duck foot coupling

Version with threaded flange and 90 elbow

TYPE

EN 1092-2
PN 10

B-GMN 30-65B-60
B-GMN 30-65A-60

DN1
80
80

DN2
65
65

Dimensions
mm
f
456
515

HL
300
330

hf
78
78

h1
90
90

h2
596
655

a1
133
133

255

a2
145
145

d1
625
625

Weight
d2
495
495

d3
357
357

d4
767
774

L1
358
365

L2
220
220

L3
289
333

L4
458
510

kg
58
79

B-GM 60 Hz

B 10

Submersible pumps

Dimensions and weights


13

B-GMV4 50-80..60
B-GMN 30-80..60

d1 min.

78
83

d2
33

85

d3

100

180

116

DN 80

EN 1092-2
PN 10

370
256

DN 80

EN 1092-2
PN 10

200

HL

hf
h1
HL minimum submersible level

DN 80

EN 1092-2
PN 10

250

L2

100

100

20

L3

210

160

L4

160

210

L1

18
d4
131

h2

a2

140

a1

412 min

80

185

185

Version with duck foot coupling

Version with threaded flange and 90 elbow

TYPE
B-GMV4 50-80A-60
B-GMN 30-80B-60
B-GMN 30-80A-60

EN 1092-2
PN 10

Dimensions
mm

Weight
kg

DN1
80

DN2
80

f
519

HL
363

hf
84

h1
116

h2
659

a1
136

a2
157

d1
658

d2
511

d3
366

d4
791

L1
365

L2
220

L3
355

L4
544

67

80

80

515

330

110

90

655

133

145

700

511

366

791

365

220

355

544

79

256

GM 60 Hz

Submersible pumps

Installation with duck foot coupling

Allarme
Alarm

1 Submersible pump

2 Duck foot coupling

3 Guide pipes

Marcia 2
Activation 2

Marcia 1
Activation 1

4 Delivery pipe
Arresto
Stop

5 Check valve
6 Gate valve

7 Level floats
8 Control box

34

257

GM 60 Hz

Submersible pumps

Accessories
Non-return ball valves
Construction
Non-return self-cleaning ball valves, suitable for dirty and viscous liquids, sewage water.

Operating conditions
Working temperature from -10C up to +80C
Rated pressure: 10 bar
Vertical or horizontal installation

Materials
Valve body: Cast iron EN-GJL-250
Cover:
Cast iron EN-GJL-250
Ball:
Resin for threaded VNRP
Resin + nitril for VNRP DN 50-100
Cast iron + nitril for VNRP DN 125-250
Screws: SS AISI 304
Joint: nitril

Dimensions
B
DN

DN

Dimensioni - Dimensions

Dimensioni - Dimensions
mm

Peso
Weight
kg

VNRP 50

50

182

192

120

165

9,5

2,4

VNRP 65

65

204

215

124

185

14

3,6

VNRP 80

80

260

250

150

200

19,5

6,5

VNRP 100

100

300

290

180

220

23,5

VNRP 125

125

350

340

215

250

36

VNRP 150

150

400

388

245

285

38,5

VNRP 200

200

500

480

310

340

69

Peso
Weight
kg

VNRP 1 1/4

1 1/4

132

111

83

108

1,9

VNRP 1 1/2

1 1/2

145

122

90

120

173

145

110

135

2 1/2

200

175

130

155

VNRP 2
VNRP 2 1/2

mm
DN
mm

DN
mm

TYPE
TIPO
TYPE

TYPE
TIPO
TYPE

258

MXS

60 Hz

Multi-Stage Submersible Clean Water Pumps


Construction
Close coupled multi-stage submersible pumps in chromenickel stainless steel.
Hydraulic part under the motor and motor cooled by the pumped
water for safe operation also with the pump only partially immersed.
Double shaft seal with interposed oil chamber.
The suction strainer prevents the entrance of solids with diameter
bigger than: - 2,5 mm for MXS 203,204, 402,403
- 2 mm for MXS 205,206,207,404,405,406, 407.

Applications
For water supply from wells, tanks or reservoirs.
For domestic use, for civil and industrial applications, for garden
use and irrigation.
Utilization of rain water.

Operating conditions
Water temperature up to 35 C.
Minimum internal diameter of well: 132 mm.
Minimum immersion depth: 100 mm.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty.

Motor
Materials
Component
Delivery casing*

Material
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Nickel-plated Brass UNI-EN 12165-98 for MXS 205,206,207,404,405,406,407

External jacket - Suction strainer


Stage casing -Impeller
Oil chamber cover
Spacer sleeve -Motor jacket
Shaft

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)


Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Chrome-nickel steel 1.4305 EN 10088 (AISI 303)
Cr-Ni steel 1.4301 EN 10088 (AISI 304) for MXS 205,206,207,404,405,406,407
Brass P- Cu Zn 40 Pb 2 UNI 5705
Cr-Ni steel 1.4301 EN 10088 (AISI 304) for MXS 205,206,207,404,405,406,407
Steatite, carbon, NBR
Ceramic alumina, silicon carbide, NBR
Silicon carbide, Silicon carbide, NBR for MXS 205,206,207,404,405,406,407
Oil for food machinery and pharmaceutic use

Motor shield
Upper mechanical seal
Lower mechanical seal
Seal lubrication oil

2-pole induction motor, 60 Hz (n = 3450 rpm).


MXS : three-phase 220 V;
three-phase 380 V.
MXSM : single-phase 220 V, with thermal protector uo to 1,1 kW.
Control box with capacitor (and thermal device for 1,5 kW).
Float switch (on demand)
Cable: H07RN8-F, 4 G 1 mm2, length 15 m.
Insulation class F.
Protection IP 68 (for continuous immersion).
Double impregnation humidity-proof dry winding.
Constructed in accordance with EN 60335-2-41.

Special features on request


- Other voltages.
- Cable length 20 m.

* Delivery casing and external jacket as one piece only for MXS 203,204,402,403

Coverage chart n = 3450 rpm

110

U.S. g.p.m.

Imp. g.p.m.

10

20

30

10

40

20

30
350

100

MXS

90

300

ft

250

70
200

60

MXS 4..-60

MXS 2..-60

50

150
40
100

30
20

50
10
0
0
0

m3/h
l/min 20

3
40

60

5
80

6
100

7
120

10

9
140

160
72 986/60Hz

259

35

MXS

60 Hz

Multi-Stage Submersible Clean Water Pumps

Performance n = 3450 rpm


220 V 380 V

3~

MXS 203-60

4,1

2,4

MXS 204-60

4,8

2,8

MXS 205-60

6,1

MXS 206-60
MXS 207-60

IA/IN

P2

IA/IN

kW

m3/h

l/min

1,5

2,5

3,5

HP

20

450

3,3

0,75

25

450

3,3

0,9

1,2

3,5

8,0

25

450

4,7

1,1

1,5

6,6

3,8

6,7

MXSM 206-60

9,0

35

450

3,9

1,5

92,5 87,5 84

7,4

4,3

5,9

MXSM 207-60

10,6 35

450

3,4

1,5

108 102 98 93,5 88 82,5 77

220 V Capacitor

IA/IN

kW

64,5 61

Hm

59

56 52,7 49

77 72,8 70 66,8 62,8 59

45 40,3 35,3 30
55

50 44,6 38,5

80 75,5 70,7 66

60 53,5 46,3
70 62,5 54

2,5

41,6 50 58,3 66,6 83,3 100 116 133 150

3,5

Q
HP

MXS 402-60

4,8

2,8 3,75 MXSM 402-60

25

450

3,3

0,9

1,2

MXS 403-60

5,6

3,2

3,2

MXSM 403-60

25

450

3,3

1,1

1,5

MXS 404-60

6,8

3,9

5,6

MXSM 404-60

8,9

25

450

4,2

1,1

1,5

MXS 405-60

7,6

4,4

5,8

MXSM 405-60

10,8

35

450

3,3

1,5

MXS 406-60

9,5

5,5

7,1

2,2

MXS 407-60

11,1

6,4 6,15

2,2

P2 Rated motor power output.


IA/IN = D.O.L. starting current / Rated current

48,5 46 44,3 42 39,5 36,8 33,8 30,2 26,5 22,5

m3/h

P2
IA/IN

4,5

16,6 25 33,3 41,6 50 58,3 66,6 75 83,3

6,5

1~

3,2 MXSM 203-60


3,75 MXSM 204-60
6,2 MXSM 205-60

220 V 380 V

3~

220 V Capacitor

1~

l/min

Hm

30,5 28 27,5 27 26 24 21 18 14,5 11


46 42,5 41,5 40,5 39 36 32 27,5 22 16,5
62,3 59 58 56,5 55,7 53 49,7 45 38,8 31,4
78 73,5 72,5 71 69,5 66,5 62 56,5 48,5 39,3
93,5 88,3 87,5 85 83,5 79,7 74,5 67,7 58,3 47
109 103 102 99 97,5 93 87 79 68 55

Test results with clean cold water, without gas content.


Tolerances according to ISO 9906, annex A.

Dimensions and weights


2

G 1 1/4
ISO 228

G 1 1/4
ISO 228

Weights

with cable length: 15 m

Picture

13

MXS

MXS 203-60
MXS 204-60
MXS 205-60
MXS 206-60
MXS 207-60
MXS 402-60
MXS 403-60
MXS 404-60
MXS 405-60
MXS 406-60
MXS 407-60

MXSM 203-60
MXSM 204-60
MXSM 205-60
MXSM 206-60
MXSM 207-60
MXSM 402-60
MXSM 403-60
MXSM 404-60
MXSM 405-60
-

MXSM 203-60 CG
MXSM 204-60 CG
MXSM 205-60 CG
MXSM 206-60 CG
MXSM 207-60 CG
MXSM 402-60 CG
MXSM 403-60 CG
MXSM 404-60 CG
MXSM 405-60 CG
-

448
448
504
578
602
448
472
480
554
578
602

12,9
13,1
17,0
18,5
19,0
14
14,5
16,0
18,5
21,0
21,5

kg
MXSM MXSM .CG
13,9
14,1
18,0
20,5
21,0
15,6
16
17,5
20,5
-

14,2
14,4
18,3
20,8
21,3
15,9
16,3
17,8
20,8
-

3.93.007

H
mm

Pump

129

102

MXSM . . . CG
With float switch pump
(on demand)

Control box for single-phase pumps


Pump

kg 0,4
75

Pg 11

76

MXSM 203-60 - MXSM 203-60 CG

Control box

Capacitor

QM 11

20 F

450 V

QM 12

25 F

450 V

QM 14

35 F

450 V

MXSM 204-60 - MXSM 204-60 CG


MXSM 205-60 - MXSM 205-60 CG
MXSM 402-60 - MXSM 402-60 CG
MXSM 403-60 - MXSM 403-60 CG

200

130

MXSM 404-60 - MXSM 404-60 CG


MXSM 206-60 - MXSM 206-60 CG
MXSM 207-60 - MXSM 207-60 CG
Pg 11

MXSM 405-60 - MXSM 405-60 CG

260

MXS

60 Hz

Multi-Stage Submersible Clean Water Pumps

Performance n = 3450 rpm


0

U.S. g.p.m. 5

Imp. g.p.m.

10
5

15

20

10

15

U.S. g.p.m. 10

Imp. g.p.m.

20

30

10

40

20

30

110

110

MXS 407-60

350

MXS 207-60

100

MXS 2

MXS 4

100
300

90

350

MXS 406-60

90

300

MXS 206-60

Hm

Hm

ft

80

ft

80
250

MXS 205-60
70

MXS 405-60

250

MXS 404-60

200

MXS 403-60

150

MXS 402-60

100

70

MXS 204-60

200

60

50

60

50

MXS 203-60

150
40

40
100

30

30

20

20

50

50
10

0
0

m3/h

Q l/min

2
20

30

40

3
50

4
60

10

5
70

80

50

60

30

40

20

30

m3/h

0
0

Q l/min

Q m3/h

2
40

4
60

5
80

6
100

7
120

9
140

20

10
0

Q m3/h

72.583/1

10
160

72.584/1

10

35

261

MXS

60 Hz

Multi-Stage Submersible Clean Water Pumps

Features

Low Cost Installation


Immersed without suction pipe and valves. The cylindrical
suction strainer, with smaller diameter with respect to the
pump, allows for obstacle-free suction also from wells with the
minimum diameter of 132 mm or, with its robust stainless
steel construction, for supporting the pump when positioned
on the flat surface of a tank for operation with the minimum
water level of 100 mm.

Low-Noise Operation
The design of hydraulic parts, the water-filled shroud around
the motor and the submersed pump allow for low-noise
operation.

Reliable and Environment Friendly


With hydraulic parts in cold-pressed d r a w n s t a i n l e s s
steel.
The only pump of its kind with no components in plastic
material.

Greater Safety
With submersed pumps protected against dry running and
the danger of freezing. No filling operations at start-up and no
suction problems. The double shaft sealing with an
interposed oil chamber separates the motor from the water
and provides further protection against accidental operation
when dry.
3.93.111

Installation

max 20 m

Max. 600 mm

Off

0.5 m
min

Off

132 mm
min
3.93.007/1

Pump in suspended position

3.93.007/3

3.93.007/2

Pump with float switch (on demand)


262

Installation example

SD

60 Hz

Submersible borehole pumps for 4 and 6 wells


Construction
Submersible borehole pumps for 4 wells (DN 100), and
6 (DN 150), with external jacket in stainless steel AISI 304
and stages in polycarbonate for 4SD pumps and in Noryl for
4SDF, 6SD, 6SDN pumps.
Impellers
radial floating impellers
radial impellers
mixed flow impellers

4SDF 16, 22, 36, 46, 54


4SD 31, - 6SDN 12, 16, 21
4SD 10, 15 - 6SD 18, 19, 20

Connection: screwed connection ISO 228.


Delivery casing with built-in non-return valve.

Applications
For
For
For
For

water supply.
civil and industrial applications.
fire fighting applications.
irrigation.

Operating conditions
Liquid temperature: up to 35 C for 4 motors.
up to 25 C for 6 motors.
Max. sand quantity into the water: 150 g/m3.
Continuous duty.

4, 6 Rewindable motor CS series


2-pole induction motor, 60 Hz (n = 3450 rpm).
With water wetted winding in rewindable execution.
Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- single-phase 220 V up to 2,2 kW
- three-phase 220 V; 380 V; 220/380 V; 380/660 V.
Voltage tolerance : 5%.
Recommended type of starting for powers from 7.5 kW:
star/delta, soft start, impedance starting, autotransformer.
Motor
4
6

Pump

Components
Part Nr.
4SD, 4SDF
6SD - 6 SDN
External jacket
14.02
Cr-Ni steel AISI 304
Stage casing (4SDF) 25.02 Cr-Ni steel AISI 304
Stage casing (4,6SD) 25.02
Polycarbonate
(Lexan 141 R)
GFN2V*
Diffuser
26.00
(NORYL)
Impeller
28.00 GFN2V* (NORYL)* for 4SDF
Wear ring
Cr-Ni steel AISI 304
Shaft
64.00
Cr steel AISI 430 F
Delivery casing
12.01
Bronze
Suction lantern
32.02
G-Cu Sn 10 EN 1982
Strainer
Screws
* Trademark of General Electric

Cooling
Max. starts
minimum flow velocity
per hour
0,08 m/s
20
0,20 m/s for 4 15 kW
15
0,50 m/s for 18,5 30 kW

Insulation class F for 4 motors, PVC coated wire for 6 motors.


Protection IP 68.

Materials

Bearing bush

Max. Liquid
temperature
35 C
25 C

12.03-12.30
15.50

Thermoplastic

Rubber

Cable
Motor 220V - 60Hz - 1~
4CS 0,37 2,2 kW
Motor 380V - 60Hz - 3 ~
4CS 0,37 2,2
4CS
3 5,5
6CS 4 26
6CS
30

kW
kW
kW
kW

Section
4G2

mm2

Section
4G2
4G2
3+1x6
3 + 1 x 10

mm2
mm2
mm2
mm2

Length
2

Length
2
3,5
3,5
3,5

m
m
m
m

Special features on request


- Other voltages.
- Other temperatures.

Cr-Ni steel AISI 430


Cr-Ni steel AISI 304

Designation
Components

Motor

External frame

4CS

4 SD M

6CS

Cr-Ni steel AISI 304

Shaft

Cr-Ni-Mo steel
Cr steel AISI 420
AISI 316 (shaft end) Hardened and tempered

Thrust bearing

Oil wetted ball type

Oscillation pads

Bearing bush

Oil wetted ball type

Graphite

263

of the well in inches


Series
Single-phase motor (up to max. 2,2 kW)
Stage identification
Number of stages
Frequency 60 Hz

31 / 36 - 60

36

SD

60 Hz

Submersible borehole pumps for 4 and 6 wells

Coverage charts n = 3450 rpm


3

U.S. g.p.m.

10

30

20
20

10

Imp. g.p.m.

40

50

30

100

40

50

100

500
400

4SD, 4SDF

300

1000

H
ft

200

H
m

4SD 31

500

4SDF
46

4SDF 22
4SDF 16

400

100

300

4SDF 36

200

4SDF 54

50
40

4SD 10

4SD 15
100

30

20
50
40
10

30

20
5
0.5

m 3/h

Q l/min

10

15

20

30

3
50

40

6
100

9 10
150

20
200

300

30
500

400

72.825.08

20

30
20

40
30

50

100

U.S. g.p.m.

40

50

200

300

100

Imp. g.p.m.

400

200

300

500
400

6SD

300

1000

H
ft

200

500

H
m

6SDN 12

400

100

300

6SDN 16

6SDN 21

200

6SD 18
50

6SD 19 6SD
20

40
100

30

20
50
40
10

30

20
5
3
50

6
100

m 3/h

9 10
200

Q l/min

20
300

400

30
500

40

50

100
1000

1500
72.827.N

264

4SD

60 Hz

Submersible borehole pumps for 4 wells

Performance n 3450 rpm


3~

Rated Max
Current Current

Rated Max
Current Current

1~

380V 380V
4SD 31/11EC-60
4SD 31/15EC-60
4SD 31/21EC-60
4SD 31/26EC-60
4SD 31/36EC-60
4SD 31/46EC-60
4SDF 16/6EC-60
4SDF 16/8EC-60
4SDF 16/12EC-60
4SDF 16/15EC-60
4SDF 16/21EC-60
4SDF 16/27EC-60
4SDF 16/37EC-60
4SDF 22/4EC-60
4SDF 22/6EC-60
4SDF 22/9EC-60
4SDF 22/11EC-60
4SDF 22/16EC-60
4SDF 22/21EC-60
4SDF 22/28EC-60
4SDF 22/38EC-60
4SDF 36/4EC-60
4SDF 36/6EC-60
4SDF 36/8EC-60
4SDF 36/10EC-60
4SDF 36/14EC-60
4SDF 36/19EC-60
4SDF 36/25EC-60
4SDF 36/35EC-60
4SDF 46/4EC-60
4SDF 46/6EC-60
4SDF 46/8EC-60
4SDF 46/11EC-60
4SDF 46/15EC-60
4SDF 46/20EC-60
4SDF 46/28EC-60
4SDF 46/35EC-60
4SDF 46/37EC-60
4SDF 54/4EC-60
4SDF 54/5EC-60
4SDF 54/7EC-60
4SDF 54/9EC-60
4SDF 54/13EC-60
4SDF 54/18EC-60
4SDF 54/22EC-60
4SDF 54/24EC-60
4SDF 54/28EC-60
4SDF 54/33EC-60

3~
4SD 10/3EC-60
4SD 10/4EC-60
4SD 10/5EC-60
4SD 10/7EC-60
4SD 10/9EC-60
4SD 10/12EC-60
4SD 10/13EC-60
4SD 10/18EC-60
4SD 15/5EC-60
4SD 15/6EC-60
4SD 15/9EC-60
4SD 15/11EC-60
4SD 15/12EC-60
4SD 15/14EC-60
4SD 15/16EC-60

IA/IN

220V 220V

IA/IN

1,6
1,6
1,85
2,35
3,3
4,5
1,6
1,6
1,85
2,35
3,3
4,5
6,2
1,6
1,6
1,85
2,35
3,3
4,5
6,2
7,9
1,6
1,6
1,85
2,35
3,3
4,5
6,2
7,9
1,6
1,85
2,35
3,3
4,5
6,2
7,9
10
10
1,85
2,35
3,3
4,5
6,2
7,9
10
10
13,3
13,3

1,9
1,9
2,4
2,9
3,8
5,1
11,9
1,9
2,4
2,9
3,8
5,1
6,8
1,9
1,9
2,4
2,9
3,8
5,1
6,8
8,7
1,9
1,9
2,4
2,9
3,8
5,1
6,8
8,7
1,9
2,4
2,9
3,8
5,1
6,8
8,7
11,3
11,3
2,4
2,9
3,8
5,1
6,8
8,7
11,3
11,3
15,1
15,1

5,4
5,4
4,6
5,1
5,5
5,5
5,4
5,4
4,6
5,1
5,5
5,5
6,4
5,4
5,4
4,6
5,1
5,5
5,5
6,4
6,6
5,4
5,4
4,6
5,1
5,5
5,5
6,4
6,6
5,4
4,6
5,1
5,5
5,5
6,4
6,6
7,2
7,2
4,6
5,1
5,5
5,5
6,4
6,6
7,2
7,2
7,6
7,6

3,9
3,9
5,3
6,7
9,1
12,8
3,9
3,9
5,3
6,7
9,1
12,8
16,3
3,9
3,9
5,3
6,7
9,1
12,8
16,3

5,1
5,1
6,6
8,4
10,7
14
5,1
5,1
6,6
8,4
10,7
14
17,4
5,1
5,1
6,6
8,4
10,7
14
17,4

3,8
3,8
4,4
4,4
4,3
4
3,8
3,8
4,4
4,4
4,3
4
4
3,8
3,8
4,4
4,4
4,3
4
4

3,9 5,1
4SDFM 36/4EC-60
3,9 5,1
4SDFM 36/6EC-60
5,3 6,6
4SDFM 36/8EC-60
4SDFM 36/10EC-60 6,7 8,4
4SDFM 36/14EC-60 9,1 10,7
4SDFM 36/19EC-60 12,8 14
4SDFM 36/25EC-60 16,3 17,4

3,8
3,8
4,4
4,4
4,3
4
4

4SDM 31/11EC-60
4SDM 31/15EC-60
4SDM 31/21EC-60
4SDM 31/26EC-60
4SDM 31/36EC-60
4SDM 31/46EC-60
4SDFM 16/6EC-60
4SDFM 16/8EC-60
4SDFM 16/12EC-60
4SDFM 16/15EC-60
4SDFM 16/21EC-60
4SDFM 16/27EC-60
4SDFM 16/37EC-60
4SDFM 22/4EC-60
4SDFM 22/6EC-60
4SDFM 22/9EC-60
4SDFM 22/11EC-60
4SDFM 22/16CE-60
4SDFM 22/21EC-60
4SDFM 22/28EC-60

4SDFM 46/4EC-60
4SDFM 46/6EC-60
4SDFM 46/8EC-60
4SDFM 46/11EC-60
4SDFM 46/15EC-60
4SDFM 46/20EC-60

3,9
5,3
6,7
9,1
12,8
16,3

5,1
6,6
8,4
10,7
14
17,4

4SDFM 54/4EC-60
4SDFM 54/5EC-60
4SDFM 54/7EC-60
4SDFM 54/9EC-60
4SDFM 54/13EC-60

5,3
6,7
9,1
12,8
16,3

6,6 4,4
8,4 4,4
10,7 4,3
14
4
17,4 4

Rated Max
Current Current

1~

380V 380V
A

2,35
3,3
4,5
6,2
7,9
9,6
9,6
13,3
4,5
6,2
7,9
10
10
13,3
13,3

2,9
3,8
5,1
6,8
8,7
10,8
11,2
15,1
5,1
6,8
8,7
11,3
11,3
15,1
15,1

IA/IN
5,1
5,5
5,5
6,4
6,6
6,7
4,7
4,1
5,4
6,4
6,6
7,2
7,2
7,6
7,6

IA/IN kW

4SDM 10/3EC-60
4SDM 10/4EC-60
4SDM 10/5EC-60
4SDM 10/7EC-60

4SDM 15/5EC-60
4SDM 15/6EC-60

= D.O.L. starting current / Rated current

Rated Max
Current Current

3,8
4,4
4,4
4,3
4
4

HP

0,37
0,37
0,55
0,75
1,1
1,5
0,37
0,37
0,55
0,75
1,1
1,5
2,2
0,37
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,5
2,2
3
4
4
0,55
0,75
1,1
1,5
2,2
3
4
4
5,5
5,5

n 3450 1/min

P2

0,5
0,5
0,75
1
1,5
2
0,5
0,5
0,75
1
1,5
2
3
0,5
0,5
0,75
1
1,5
2
3
4
0,5
0,5
0,75
1
1,5
2
3
4
0,5
0,75
1
1,5
2
3
4
5,5
5,5
0,75
1
1,5
2
3
4
5,5
5,5
7,5
7,5

P2

m /h

0,3

0,6

0,9

1,2

1,5

1,8

2,1

2,4

3,6 3,9

4,2

4,8

l/min

10

15

20

25

30

35

40

50

60

65

70

80

67,5
92,5
130
160
222
283
49,9
66,6
99,9
125
175
225
308
36,5
54,7
82,1
100
146
192
255
347

63,5
84,5
121
150
207
265
48,6
64,8
97,2
121
170
219
300
36
54
81,1
99,1
144
189
252
342
30,3
45,4
60,6
75,7
106
144
189
265

58
79
110
137
189
242
46,6
62,2
93,2
117
163
210
287
35,3
53
79,4
97,1
141
185
247
335
29,7
44,5
59,4
74,2
104
141
186
26
32,2
48,4
64,5
88,6
121
161
226
282
298

51,5
70,5
98,5
122
169
216
43,9
58,5
87,8
110
154
198
271
34,3
51,4
77,1
94,3
137
180
240
326
29,1
43,6
58,2
72,7
102
138
182
254
31,7
47,6
63,5
87,3
119
159
222
278
294
35,9
44,9
62,8
80,8
117
162
198
215
251
296

42,5
57,5
80,5
100
138
177
40,4
53,9
80,8
101
141
182
249
32,9
49,4
74,1
90,5
132
173
230
313
28,4
42,6
56,8
71
99,4
135
178
249
31,2
46,8
62,4
85,8
117
156
218
273
289
35,5
44,3
62,1
79,8
115
160
195
213
248
293

33,5
45,5
64
79
109
140
36,3
48,3
72,5
90,6
127
163
224
31,2
46,8
70,2
85,8
125
164
218
296
27,6
41,5
55,3
69,1
96,7
131
173
242
30,6
45,9
61,2
84,1
115
153
214
268
283
35
43,8
61,3
78,8
114
158
193
210
245
289

24
32,5
45,5
56,5
78
99,5
31,5
42
63
78,8
110
142
194
29,1
43,7
65,6
80,1
117
153
204
277
26,8
40,1
53,5
66,9
93,7
127
167
234
29,9
44,9
59,8
82,3
112
150
209
262
277
34,5
43,1
60,4
77,6
112
155
190
207
242
285

14,5
21,8
32,7
40
58,1
76,3
102
138
20,6
30,9
41,2
51,4
72
97,7
129
180
25,3
37,9
50,6
69,5
94,8
126
177
221
234
31,5
39,4
55,2
70,9
102
142
173
189
221
260

11
16,5
24,7
30,2
43,9
57,6
76,8
104
19,1
28,6
38,1
47,7
66,8
90,6
119
167
24,1
36,2
48,3
66,4
90,5
121
169
211
223
30,8
38,5
54
69,4
100
139
170
185
216
254

17,5
26,3
35
43,8
61,3
83,2
110
153
22,9
34,4
45,9
63,1
86
115
161
201
212
30,1
37,6
52,7
67,8
97,9
136
166
181
211
249

14,3
21,5
28,7
35,8
50,2
68,1
89,6
125
20,4
30,6
40,8
56,1
76,5
102
143
178
189
28,6
35,7
50
64,3
92,8
129
157
171
200
236

4,8

7,2

H
m

220V 220V
A
A IA/IN kW HP
6,7 8,4 4,4 0,75 1
9,1 10,7 4,3 1,1 1,5
12,8 14
4
1,5
2
16,3 17,4 4
2,2
3
3
4
4
5,5
4
5,5
5,5 7,5
12,8 14
4
1,5
2
16,3 17,4 4
2,2
3
3
4
4
5,5
4
5,5
5,5 7,5
5,5 7,5

l/min

H
m

7,2

8,4

9,6

7,7
11,6
15,4
19,3
27
36,7
48,3
67,6
14,9
22,4
29,8
41
55,9
74,6
104
131
138
25,0
31,3
43,8
56,3
81,3
113
138
150
175
206

8,6
12,9
17,2
23,6
32,2
42,9
60,1
75,1
79,4
20,9
26,1
36,5
47
67,8
93,9
115
125
146
172

16,3
20,3
28,5
36,6
52,9
73,2
89,5
97,6
114
134

18

21

24

11
13,8
19,3
24,9
35,9
49,7
60,8
66,3
77,3
91,1

n 3450 1/min

Q
m3/h

13,5
18,5
26
32
44,5
57
26,2 13,8
34,9 18,4
52,4 27,6
65,5 34,5
91,7 48,3
118 62,1
161 85,1
26,8 21,1
40,1 31,7
60,2 47,5
73,6 58
107 84,4
140 111
187 148
254 201
25,8 23,4
38,6 35,1
51,5 46,7
64,4 58,4
90,1 81,8
122 111
161 146
225 204
29,1 27,4
43,7 41,1
58,3 54,7
80,2 75,3
109 103
146 137
204 192
255 239
270 253
34 32,8
42,5 41,0
59,4 57,4
76,4 73,8
110,4 107
153 148
187 180
204 197
238 230
280 271

100 120 140 160

1,2

2,4

3,6

20

40

60

80

30
40
50
70
90
120
130
180

29
39
49
69
89
118
128
177
40,4
48,5
72,7
88,9
96,9
113
129

28
38
47
66
85
113
122
171
39,5
47,4
71,1
86,9
94,8
111
126

27
37
45
63
81
108
117
164
38,5
46,2
69,2
84,6
92,3
108
123

P2 Rated motor power output

265

8,4 9,6 10,8 12 13,2 14,4 15

100 120 140 160 180 200 220 240 250 300 350 400
26
34
43
61
78
104
113
156
37,3
44,8
67,2
82,1
89,6
105
120

25
33
41
57
74
98
106
147
36,1
43,3
65
79,4
86,6
101
116

H Total head in m

23
30
38
53
68
91
99
136
34,7
41,7
62,5
76,4
83,4
97,2
111

21
27
34
48
62
83
90
124
33,3
39,9
59,9
73,2
79,9
93,2
107

18
24
30
43
55
73
79
110
31,7
38,1
57,1
69,8
76,2
88,8
102

14
20
25
36
46
61
66
94
30,1
36,1
54,2
66,2
72,2
84,3
96,3

12
16
20
29
36
48
52
75
28,4
34,1
51,1
62,4
68,1
79,5
90,8

9
12
15
21
27
36
39
54
26,6
31,9
47,9
58,5
63,8
74,4
85,1

25,7
30,8
46,2
56,4
61,6
71,8
82,1

20,8
24,9
37,4
45,7
49,9
58,2
66,5

15,5
18,6
28,0
34,2
37,3
43,5
49,7

10
12
18
22
24
28
32

Tolerances according to ISO 9906, annex A

36

4SD 31 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0

U.S. g.p.m.

Imp. g.p.m.

2.5

7.5

2.5

10

7.5

380
1200

G 1 1/4

4SD 31
1000

300

H
ft

46

H
m

800
L1

36
200
600

26
21
100

400

15
11
200

0
0
0

m3/h
l/min

0
0.5

1
10

l/s

1.5

20
0.2

0.3

30
0.4

3.93.063.2N

2.5

96

40

0.5

0.6

50

0.05

40

98

kW/st

%
kW/st

0.04

20
10
0.03

0
0

m /h

3~

0.5

Rated Max
Current Current

1,6

IA/IN kW

IA/IN

m3/h
HP l/min

3,9

5,1

3,8 0,37 0,5

2.5

n 3450 1/min

P2

220V 220V

1,9 5,4 4SDM 31/11EC-60

72.1127

Rated Max
Current Current

1~

380V 380V

4SD 31/11EC-60

1.5

4SD

0,3

0,6

0,9

1,2

1,5

1,8

2,1

2,4

10

15

20

25

30

35

40

4SDM

L1
mm

L
mm

71 67,5 63,5 58 51,5 42,5 33,5 24 13,5

473

800

10,3 800

10,3

10,9 877

10,9

kg

L
mm

1,9 5,4 4SDM 31/15EC-60 3,9

5,1

3,8 0,37 0,5

97 92,5 84,5 79 70,5 57,5 45,5 32,5 18,5

550

877

4SD 31/21EC-60 1,85 2,4 4,6 4SDM 31/21EC-60 5,3

6,6

4,4 0,55 0,75

136 130 121 110 98,5 80,5 64 45,5 26

670

997

4SD 31/26EC-60 2,35 2,9 5,1 4SDM 31/26EC-60 6,7

8,4

4,4 0,75

168 160 150 137 122 100

768 1115 13,6 1145

4SD 31/15EC-60 1,6

4SD 31/36EC-60 3,3

3,8 5,5 4SDM 31/36EC-60 9,1 10,7 4,3

1,1

1,5

4SD 31/46EC-60 4,5

5,1 5,5 4SDM 31/46EC-60 12,8 14

1,5

P2 Rated motor power output

H Total head in m

H
m

79 56,5 32

233 222 207 189 169 138 109

78 44,5

298 283 265 242 216 177 140 99,5 57

Tolerances according to ISO 9906, annex A

266

12

kg

1017 12,8
15

965 1342 16,6 1372 17,3


1160 1567 18,9 1627 20,5

4SDF 16 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0
0

1 U.S. g.p.m

1 Imp. g.p.m 3

5
4

9
7

10
8

11

12

10

13

14

11

12

340

1100

4SDF 16

37

300

G 1 1/4

1000

900

ft
800

m
27

700
L1

200
600

21

500
15

400

12

100

300
8
200

100

0
0
0

0,6
10

m3/h
Q
l/min

0,9
15

1,2
20

1,5
25

1,8
30

2,1
35

2,4
40

2,7
45

3.93.063.2N

0
3,3
55

3
50

96

72.1172

50

40

98

kW/st

30

0,07

20

0,06

kW/st

0,05

0
0

Q m3/h

0,9

1,2

1,5

1,8

2,1

2,4

2,7

0,04
3,3

36
3~

Rated Max
Current Current

1~

380V 380V

Rated Max
Current Current

A IA/IN

IA/IN kW

n 3450 1/min

P2

4SDF

m3/h

0,3

0,6

0,9

1,2

1,5

1,8

2,1

2,4

HP l/min

10

15

20

25

30

35

40

50

220V 220V

4SDFM

L1
mm

L
mm

kg

L
mm

kg

11

632

11

4SDF 16/6EC-60

1,6

1,9 5,4 4SDFM 16/6EC-60

3,9

5,1

3,8 0,37 0,5

50,9 49,9 48,6 46,6 43,9 40,4 36,3 31,5 26,2 13,8

305

632

4SDF 16/8EC-60

1,6

1,9 5,4 4SDFM 16/8EC-60

3,9

5,1

3,8 0,37 0,5

67,8 66,6 64,8 62,2 58,5 53,9 48,3 42 34,9 18,4

345

672

11,3

672

11,3

4SDF 16/12EC-60 1,85 2,4 4,6 4SDFM 16/12EC-60 5,3

6,6

4,4 0,55 0,75

102 99,9 97,2 93,2 87,8 80,8 72,5 63 52,4 27,6

425

752

12,1 772

13,1

4SDF 16/15EC-60 2,35 2,9 5,1 4SDFM 16/15EC-60 6,7

8,4

4,4 0,75

127 125 121 117 110 101 90,6 78,8 65,5 34,5

485

832

13,6 862

14,8

178 175 170 163 154 141 127 110 91,7 48,3

605

982

4SDF 16/21EC-60 3,3

3,8 5,5 4SDFM 16/21EC-60 9,1 10,7 4,3

1,1

1,5

4SDF 16/27EC-60 4,5

5,1 5,5 4SDFM 16/27EC-60 12,8 14

1,5

229 225 219 210 198 182 163 142 118 62,1

725 1132 18,5 1192 20,8

4SDF 16/37EC-60 6,2

6,8 6,4 4SDFM 16/37EC-60 16,3 17,4

2,2

314 308 300 287 271 249 224 194 161 85,1

915 1422 24,1 1432 25,8

P2 Rated motor power output

H Total head in m

Tolerances according to ISO 9906, annex A

267

16

1012 17,3

4SDF 22 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. g.p.m

0 Imp. g.p.m

5
4

10 11 12 13 14 15 16 17 18
8

10

11

12

13

14

15

380
G 1 1/4

1200
38

4SDF 22

1100
1000

300

H
ft
900
28

H
m

800
L1

700
200

21
600
L

500

16

400
11

100

300

9
6

200

100

0
0
0

m3/h 0,6
Q
l/min 10

0,9
15

1,2
20

1,5
25

1,8
30

2,1
35

2,4
40

2,7
45

3
50

3,3
55

3,6
60

3,9
65

3.93.063.2N

4,2
70

96

72.1173

60

50

98

kW/st

40

0,10

30

0,08

kW/st

0,06

10
0

Q m3/h

3~

1,2

Rated Max
Current Current

1,8

1~

380V 380V

2,4

Rated Max
Current Current

IA/IN kW

n 3450 1/min

P2

4SDF

m3/h

0,3

0,6

0,9

1,2

1,8

2,4

3,6

3,9

HP l/min

10

15

20

30

40

50

60

220V 220V

A IA/IN

0,04
4,2

3,6

65

L1
mm

L
mm

kg

4SDFM
L
mm

kg

1,6

1,9 5,4 4SDFM 22/4EC-60

3,9

5,1

3,8 0,37 0,5

36,8 36,5 36 35,3 34,3 31,2 26,8 21,1 14,5 11

265

592

4SDF 22/6EC-60

1,6

1,9 5,4 4SDFM 22/6EC-60

3,9

5,1

3,8 0,37 0,5

55,2 54,7 54

53 51,4 46,8 40,1 31,7 21,8 16,5

305

632

11

632

11

4SDF 22/9EC-60

1,85 2,4 4,6 4SDFM 22/9EC-60

5,3

6,6

4,4 0,55 0,75

82,8 82,1 81,1 79,4 77,1 70,2 60,2 47,5 32,7 24,7

365

692

11,5

712

12,5

4SDF 22/11EC-60 2,35 2,9 5,1 4SDFM 22/11EC-60 6,7

8,4

4,4 0,75

101 100 99,1 97,1 94,3 85,8 73,6 58

12,9 782

14,1

4SDF 22/4EC-60

40 30,2

405

752

505

882

193 192 189 185 180 164 140 111 76,3 57,6

605 1012 17,35 1072 19,6

2,2

257 255 252 247 240 218 187 148 102 76,8

745 1252 22,4 1262 24,1

349 347 342 335 326 296 254 201 138 104

935 1408 24,3

3,8 5,5 4SDFM 22/16EC-60 9,1 10,7 4,3

1,1

1,5

4SDF 22/21EC-60 4,5

5,1 5,5 4SDFM 22/21EC-60 12,8 14

1,5

4SDF 22/28EC-60 6,2

6,8 6,4 4SDFM 22/28EC-60 16,3 17,4

4SDF 22/38EC-60 7,9

8,7 6,6

H Total head in m

10,6

147 146 144 141 137 125 107 84,4 58,1 43,9

4SDF 22/16EC-60 3,3

P2 Rated motor power output

10,6 592

H
m

Tolerances according to ISO 9906, annex A

268

15

912

16,4

4SDF 36 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0
0

2
2

U.S. g.p.m

Imp. g.p.m

10

12

10

14

16

12

18

14

20

22

16

24

18

26

20

22

28
24
G 1 1/4

1000

300

4SDF 36

39

900
35

H
m

800

H
ft
700
200
25

L1

600

500

19

400
14

100

300
10
8

200

6
4

100

0
0
0

1,2
20

m3/h
Q
l/min

1,8
30

2,4
40

3
50

3,6
60

4,2
70

4,8
80

5,4
90

3.93.063.2N

6,6
110

6
100

96

72.1174

60

50

98

kW/st

40

0,10

30

0,09
kW/st

0,08

10

0,07
0

Q m3/h

1,8

2,4

3,6

4,2

4,8

5,4

6,6

36
3~

Rated Max
Current Current

1~

380V 380V

Rated Max
Current Current

A IA/IN

IA/IN kW

n 3450 1/min

P2

4SDF

m3/h

0,6

1,2

1,8

2,4

3,6

4,2

4,8

HP l/min

10

20

30

40

50

60

70

80

220V 220V

100

L1
mm

L
mm

kg

4SDFM
L
mm

kg

1,6

1,9 5,4 4SDFM 36/4EC-60

3,9

5,1

3,8 0,37 0,5

31,4 30,3 29,1 27,6 25,8 23,4 20,6 17,5 14,3 7,7

290

617

10,7 617

4SDF 36/6EC-60

1,6

1,9 5,4 4SDFM 36/6EC-60

3,9

5,1

3,8 0,37 0,5

47,1 45,4 43,6 41,5 38,6 35,1 30,9 26,3 21,5 11,6

340

667

11,1

667

11,1

4SDF 36/8EC-60

1,85 2,4 4,6 4SDFM 36/8EC-60

5,3

6,6

4,4 0,55 0,75

62,8 60,6 58,2 55,3 51,5 46,7 41,2 35 28,7 15,4

395

722

11,6

742

12,6

4SDF 36/10EC-60 2,35 2,9 5,1 4SDFM 36/10EC-60 6,7

8,4

4,4 0,75

78,5 75,7 72,7 69,1 64,4 58,4 51,4 43,8 35,8 19,3

450

797

13

827

14,2

110 106 102 96,7 90,1 81,8 72 61,3 50,2 27

555

932

15,1 962

16,5

690 1097 17,6 1157 19,9

4SDF 36/4EC-60

10,7

4SDF 36/14EC-60 3,3

3,8 5,5 4SDFM 36/14EC-60 9,1 10,7 4,3

1,1

1,5

4SDF 36/19EC-60 4,5

5,1 5,5 4SDFM 36/19EC-60 12,8 14

1,5

149 144 138 131 122 111 97,7 83,2 68,1 36,7

4SDF 36/25EC-60 6,2

6,8 6,4 4SDFM 36/25EC-60 16,3 17,4

2,2

196 189 182 173 161 146 129 110 89,6 48,3

845 1352 22,6 1362 24,3

4SDF 36/35EC-60 7,9

8,7 6,6

275 265 254 242 225 204 180 153 125 67,6

1110 1583 24,8

10 11,3 7,2

5,5

306 295 283 269 251 228 201 171 140 75,3

1220 1758 26,9

4SDF 36/39EC-60

P2 Rated motor power output

H Total head in m

Tolerances according to ISO 9906, annex A

269

4SDF 46 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. g.p.m

0 Imp. g.p.m

12

16

20

12

24

16

28

20

32

24

28

340

1100

4SDF 46

300

G 1 1/4

1000

37
900
35

ft
800

m
28

700
L1

200
600
20

500

15

400

11

300

100

200

6
4

100

0
0
0

m3/h 1,2
Q
l/min 20

1,8
30

2,4
40

3
50

3,6
60

4,2
70

4,8
80

5,4
90

6
100

6,6
110

0
7,8
130

7,2
120

3.93.063.2N

96

72.1175

60

50

98

kW/st

40

0,14

30

0,12

0,10

kW/st

10

0,08
0

Q m3/h

3~

1,8

Rated Max
Current Current

1~

380V 380V

4,2

5,4

Rated Max
Current Current

IA/IN kW

n 3450 1/min

P2

4SDF

m3/h

0,9

1,2

1,8

2,4

3,6

4,8

HP l/min

15

20

30

40

50

60

80

220V 220V

A IA/IN

7,8

6,6

7,2

4SDFM

100 120

L1
mm

L
mm

kg

L
mm

kg

9,7

617

9,7

687

12,1

4SDF 46/4EC-60

1,6

1,9 5,4 4SDFM 46/4EC-60

3,9

5,1

3,8 0,37 0,5

33,6 32,2 31,7 30,6 29,1 27,4 25,3 20,4 14,9 8,6

290

617

4SDF 46/6EC-60

1,85 2,4 4,6 4SDFM 46/6EC-60

5,3

6,6

4,4 0,55 0,75

50,3 48,4 47,6 45,9 43,7 41,1 37,9 30,6 22,4 12,9

340

667

11,1

4SDF 46/8EC-60

2,35 2,9 5,1 4SDFM 46/8EC-60

6,7

8,4

4,4 0,75

67,1 64,5 63,5 61,2 58,3 54,7 50,6 40,8 29,8 17,2

395

742

12,6 772 13,75

4SDF 46/11EC-60

3,3

3,8 5,5 4SDFM 46/11EC-60

1,1

1,5

92,3 88,6 87,3 84,1 80,2 75,3 69,5 56,1 41 23,6

475

852

14,4 882

15,8

4SDF 46/15EC-60

4,5

5,1 5,5 4SDFM 46/15EC-60 12,8 14

1,5

126 121 119 115 109 103 94,8 76,5 55,9 32,2

585

992

16,7 1052

19

4SDF 46/20EC-60

6,2

6,8 6,4 4SDFM 46/20EC-60 16,3 17,4

2,2

168 161 159 153 146 137 126 102 74,6 42,9

715 1222 21,5 1232 23,2

4SDF 46/28EC-60

7,9

8,7 6,6

235 226 222 214 204 192 177 143 104 60,1

925 1398 23,2

4SDF 46/35EC-60

10 11,3 7,2

5,5

294 282 278 268 255 239 221 178 131 75,1

1110 1648 27,9

4SDF 46/37EC-60

10 11,3 7,2

5,5

310 298 294 283 270 253 234 189 138 79,4

1165 1703 28,4

P2 Rated motor power output

9,1 10,7 4,3

H Total head in m

1
H
m

Tolerances according to ISO 9906, annex A

270

4SDF 54 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. g.p.m 8
0 Imp. g.p.m

12
8

16
12

20
16

24

28

20

32

24

36
28

40
32

44
36

340

1100
G 1 1/4

4SDF 54

300

1000

33
900

H
m

200

28

ft
800

24

700
L1

22
600
18

500

400

13
100

300

9
7

200

5
4

100

0
0
0

m3/h
Q
l/min

40

3,6
60

4,8
80

6
100

7,2
120

8,4
140

9,6
160

0
10,8
180

3.93.063.2N

96

72.1176

60

50

98

kW/st

40

0,20
kW/st

30

0,16

0,12

10
0

Q m3/h

2,4

3,6

4,8

7,2

8,4

9,6

0,08
10,8

36
3~

Rated Max
Current Current

1~

380V 380V

Rated Max
Current Current

P2

m3/h

1,2

2,4

3,6

4,2

4,8

HP l/min

20

40

60

70

80

220V 220V

A IA/IN

IA/IN kW

n 3450 1/min

4SDF

7,2

8,4

9,6

100 120 140 160

L1
mm

L
mm

4SDFM
L
mm

kg

10,6 657

11,7

kg

4SDF 54/4EC-60

1,85 2,4 4,6 4SDFM 54/4EC-60

5,3

6,6

4,4 0,55 0,75

37,4 35,9 34,0 31,5 30,1 28,6 25,0 20,9 16,3 11,0

310

637

4SDF 54/5EC-60

2,35 2,9 5,1 4SDFM 54/5EC-60

6,7

8,4

4,4 0,75

46,7 44,9 42,5 39,4 37,6 35,7 31,3 26,1 20,3 13,8

340

687

11,8

4SDF 54/7EC-60

3,3

3,8 5,5 4SDFM 54/7EC-60

9,1 10,7 4,3

1,1

1,5

65,4 62,8 59,4 55,2 52,7 50,0 43,8 36,5 28,5 19,3

400

777

13,5 807

14,9

4SDF 54/9EC-60

4,5

5,1 5,5 4SDFM 54/9EC-60

12,8 14

1,5

84,1 80,8 76,4 70,9 67,8 64,3 56,3 47,0 36,6 24,9

460

867

15,4 927

17,7

4SDF 54/13EC-60

6,2

6,8 6,4 4SDFM 54/13EC-60 16,3 17,4

2,2

122 117 110 102 97,9 92,8 81,3 67,8 52,9 35,9

580 1087

4SDF 54/18EC-60

7,9

8,7 6,6

168 162 153 142 136 129 113 93,9 73,2 49,7

730 1203 21,1

4SDF 54/22E

10 11,3 7,2

5,5

206 198 187 173 166 157 138 115 89,5 60,8

850 1388 25,4

4SDF 54/24EC-60

10 11,3 7,2

5,5

224 215 204 189 181 171 150 125 97,6 66,3

910 1448 25,8

4SDF 54/28EC-60 13,3 15,1 7,6

5,5

7,5

262 251 238 221 211 200 175 146 114 77,3

1030 1668 31,2

4SDF 54/33EC-60 13,3 15,1 7,6

5,5

7,5

309 296 280 260 249 236 206 172 134 91,1

1180 1818 32,5

P2 Rated motor power output

H Total head in m

H
m

Tolerances according to ISO 9906, annex A

271

20

717

13

1097 21,8

4SD 10 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0

U.S. g.p.m.

Imp. g.p.m.

30

20

40

20

50

60

40

30

50

200
G2

600

4SD 10

18

H
ft

150

13

H
m

400

12

L1

100
9

7
200
5

50

4
3

0
0
0

m3/h
l/min

0
5
50

100

l/s

10
150

200

60

96

0.36

3.93.063.2N

15
250

kW/st

40

98

0.32
kW/st

0.28

20

0
0

0.24

m /h

3~

Rated Max
Current Current

1~

380V 380V

72.361

10

Rated Max
Current Current

m3/h

220V 220V

IA/IN kW

n 3450 1/min

P2

15

HP l/min

1,2

2,4

3,6

4SD

8,4 10,8 12

13,2 14,4

L1
mm

L
mm

4SDM
kg

L
mm

kg

11

804

12,4
13,4

20

40

60

100 140 180 200 220 240

31

30

29

28

26

23

18

18

12

427

774

1,1

1,5

41

40

39

38

34

30

24

24

16

12

480

857

12,8 887

1,5

51

50

49

47

43

38

30

30

20

15

533

940

13,9 1000 15,4

2,2

72

70

69

66

61

53

43

43

29

21

638 1145 16,9 1155 20,4

92

90

89

85

78

68

55

55

36

27

715 1188 23,6

10 11,3 7,2

5,5

123 120 118 113 104

91

73

73

48

36

902 1440 25,2

10 11,3 7,2

5,5

133 130 128 122 113

99

79

79

52

39

925 1463 31,1

5,5

7,5

184 180 177 171 156 136 110 110

75

54

1220 1858 32,5

IA/IN

6,7

8,4

4SD 10/3EC-60

2,35 2,9 5,1 4SDM 10/3EC-60

4SD 10/4EC-60

3,3

3,8 5,5 4SDM 10/4EC-60

9,1 10,7 4,3

4SD 10/5EC-60

4,5

5,1 5,5 4SDM 10/5EC-60

12,8 14

4SD 10/7EC-60

6,2

6,8 6,4 4SDM 10/7EC-60

16,3 17,4

4SD 10/9EC-60

7,9

8,7 6,6

4SD 10/12EC-60
4SD 10/13EC-60

4SD 10/18EC-60 13,3 15,1 7,6

P2 Rated motor power output

H Total head in m

4,4 0,75

H
m

Tolerances according to ISO 9906, annex A

272

4SD 15 60 Hz

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0

U.S. g.p.m.

Imp. g.p.m.

25

50

75

25

100

50

75

150
G2

4SD 15

H
m

16

400

14

H
ft

12

300

100

L1

11

200
50

6
5
100

0
0
0

m3/h
l/min

10

15

100

200
2

l/s

20

60

96

400

300
4

0.5

3.93.063.2N

25

40

98

0.4

kW/st

kW/st

20

0.3

0
0

m /h

10

15

72.362

20

0.2
25

36
3~

Rated Max
Current Current

1~

380V 380V

Rated Max
Current Current

P2

m3/h

220V 220V

IA/IN kW

IA/IN

n 3450 1/min

Q
HP l/min

9,6

12

15

4SD

2,4

4,8

7,2

18

21

24

40

80

120 160 200 250 300 350 400

L1
mm

L
mm

4SDM
kg

L
mm

kg

4SD 15/5EC-60

4,5

5,1 5,5 4SDM 15/5EC-60

12,8 14

1,5

41,8 40,4 38,5 36,1 33,3 30,1 25,7 20,8 15,5

10

600 1007 15,8 1067 18,1

4SD 15/6EC-60

6,2

6,8 6,4 4SDM 15/6EC-60

16,3 17,4

2,2

50,2 48,5 46,2 43,3 39,9 36,1 30,8 24,9 18,6

12

680 1187 20,2 1197 21,9

4SD 15/9EC-60

7,9

8,7 6,6

75,3 72,7 69,2 65 59,9 54,2 46,2 37,4 28

18

915 1388 22,4

4SD 15/11EC-60

9,6 10,8 6,7

5,5

92 88,9 84,6 79,4 73,2 66,2 56,4 45,7 34,2

22

1070 1608 26,8

4SD 15/12EC-60

10 11,3 7,2

5,5

100 96,9 92,3 86,6 79,9 72,2 61,6 49,9 37,3

24

1145 1683 27,4

4SD 15/14EC-60 13,3 15,1 7,6

5,5

7,5

117 113 108 101 93,2 84,3 71,8 58,2 43,5

28

1375 2013 32,9

4SD 15/16EC-60 13,3 15,1 7,6

5,5

7,5

134 129 123 116 107 96,3 82,1 66,5 49,7

32

1520 2158 34,3

P2 Rated motor power output

H Total head in m

Tolerances according to ISO 9906, annex A

273

6SDN 12 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. g.p.m. 20

40

0 Imp. g.p.m. 20

60

80

40

100

40

80

400
DN

6SDN 12

6S
DN
12/
24

1200
H
ft
1000

300

21
18

800

15

200

600
12

9
100

400

6
200

0
0

m3/h
Q l/min 4

8
100

l/s

12
200

16

20

24
400

300

70
%
60

6
1.0

40

0.8
Pst
0.6
kW
0.4

30

0.2

Pst

50

20

3.93.110.2

Q m3 /h 4

P2 Rated motor power output

20

16

72.1154

3~

6SDN 12/6-60
6SDN 12/9-60
6SDN 12/12-60
6SDN 12/15-60
6SDN 12/18-60
6SDN 12/21-60
6SDN 12/24-60

12

24

7
14

1
15

n 3450 rpm

P2

kW

HP

4
5,5
7,5
9,2
11
13
15

5,5
7,5
10
12,5
15
17,5
20

m /h

l/min

H
m

12

14

16

18

20

22

50

100 133,3 166,6 200

233

266

300

333

366

87
131
174
218
261
305
348

81
122
162
203
243
284
324

71,5 67,5
107 101
143 135
179 169
214 203
250 236
286 270

60
91
122
152
183
213
244

51,5 41
77 61,5
103
82
128 103
154 123
180 144
205 165

30
45
60
75
90
105
120

H Total head in m

10

78
117
156
195
234
273
312

75
113
150
188
225
263
300

Tolerances according to ISO 9906, annex A

274

DN

L
mm

560
677
793
G3
ISO 228 908
1025
1141
1320

kg
12,8
14,5
16,2
17,9
19,6
21,3
23

6SDN 16 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0

U.S. g.p.m.

Imp. g.p.m.

60

40

80

100

60

40

120

80

100

400
DN

1200

6SDN 16

6SD
N1
6/2
1

H
ft
1000

300
17

800
15
13

200

600
L

10
8
100

400

6
4

0
0

m3/h

10

Q l/min 100
l/s

200

200

300

20

400

70
%
60

30
500

8
1.4

50

Pst

0.8

30

0.6
0

Q m 3/h

7
14

1
15

1.2
Pst
kW

40

20

3.93.110.2

10

72.1155

20

30

0.4

36
Q

3~

m /h
3

6SDN 16/4-60
6SDN 16/6-60
6SDN 16/8-60
6SDN 16/10-60
6SDN 16/13-60
6SDN 16/15-60
6SDN 16/17-60
6SDN 16/21-60
P2 Rated motor power output

n 3450 rpm

P2

kW

HP

4
5,5
7,5
9,2
11
13
15
18,5

5,5
7,5
10
12,5
15
17,5
20
25

l/min

H
m

12

15

18

21

24

27

30

66,6 133,3 200

250

300

350

400

450

500

62,5 58,5 54,7


93,5 87,5 82
125 117 109
156 146 137
203 190 178
234 219 205
265 248 233
327 307 287

52
78
104
130
169
195
221
273

50
75
100
125
163
188
213
263

43,5 35 25,5 15
65,5 52,5 38,5 23
87
70
51 30,5
109 87,5 64
38
142 114
83 49,5
164 131
96
57
185 149 109 64,5
229 184 134
80

H Total head in m

Tolerances according to ISO 9906, annex A

275

DN

L
mm

484
561
638
G3
ISO 228 715
830
907
985
1139

kg
12,5
13,5
14,5
15,5
17
18
19
21,5

6SDN 21 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0

U.S. g.p.m.

Imp. g.p.m.

50

100

150

50

100

140

400
DN

6SDN 21

6S
DN
21/
22

H
m

300

1200
H
ft
1000

20

17

800

14
200
600
11
10

100

0
0

3/h
Q m
l/min

l/s

10

8
7

400

5
4
3

200

20

200

30

400

40

600

10

60
%
40

Q m3/h

10

Q
m /h

P2 Rated motor power output

1
15

40

0.6

n 3450 rpm

P2
3

6SDN 21/3-60
6SDN 21/4-60
6SDN 21/5-60
6SDN 21/7-60
6SDN 21/8-60
6SDN 21/10-60
6SDN 21/11-60
6SDN 21/14-60
6SDN 21/17-60
6SDN 21/20-60
6SDN 21/22-60

72.1156

30

20

3~

Pst
1.4
kW
1.0

Pst

7
14

1.8

20
0

3.93.110.2

kW

HP

4
5,5
7,5
9,2
11
13
15
18,5
22
26
30

5,5
7,5
10
12,5
15
17,5
20
25
30
35
40

l/min

H
m

14

18

21

24

27

30

33

36

39

100 166,6 233

300

350

400

450

500

550

600

650

47,5 44,5 42,5 40


63 59,5 56,5 53,5
79 74,5 70,5 67
111 104 98,5 94
126 119 113 107
158 149 141 134
174 164 155 147
221 209 197 188
269 253 240 228
316 298 282 268
348 328 310 295

39
52
65
91
104
130
143
182
221
260
286

37 33,5 29
49,5 45
39
62
56 48,5
86,5 78,5 68
99 89,5 77,5
124 112
97
136 123 107
173 157 136
210 190 165
247 224 194
272 246 213

24
32
40
56
64
80
88
112
136
160
176

18
24
30
42
47,5
59,5
65,5
83,5
101
119
131

11
15
18,5
26
29,5
37
40,5
51,5
62,5
74
81

H Total head in m

10

Tolerances according to ISO 9906, annex A

276

DN

L
mm

470
517
565
660
707
G3
ISO 228 802
850
992
1135
12771
1420

kg
12,1
12,7
13,3
14,5
15,1
16,3
16,9
18,7
20,5
22,3
23,5

6SD 18 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights

300

U.S. g.p.m.

Imp. g.p.m.

80

120

160

80

200

120

160

6S
D1
8/1
4

H
m

240
200

6SD 18

DN

H
ft

250

800
CALPEDA

200

10
600
9

150
7
L

400
100

200

3
50

0
0

m3/h 10
l/min 200
l/s

20

30

400

600

40

10

60
%
40

0
60
1000

50
800
15

2.5

Pst

Pst
2.0

1
15

5
15

kW
1.5

20
0

3.93.110.21

Q m 3/h 10

20

40

30

50

72.367

60

1.0

36
Q

3~

6SD 18/2-60
6SD 18/3-60
6SD 18/5-60
6SD 18/7-60
6SD 18/9-60
6SD 18/10-60
6SD 18/14-60
P2 Rated motor power output

n 3450 rpm

P2

kW

HP

5,5
7,5
11
15
18,5
22
30

7,5
10
15
20
25
30
40

m /h

12

18

24

30

36

42

48

54

l/min

100

200

300

400

500

600

700

800

900

42
63
105
147
188
210
291

40
60
100
140
179
200
277

39
57
94
131
167
186
260

35
52
87
121
153
173
240

33
47
79
109
137
156
218

27
41
68
95
118
136
191

23
33
56
78
95
112
158

16
23
40
57
69
83
117

8
13
21
30
39
43
61

H
m

H Total head in m

Tolerances according to ISO 9906, annex A

277

DN

L
mm

542
651
870
G3
ISO 228 1088
1307
1416
1853

kg
58,5
64,5
74
86
103
121
146

6SD 19 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights

340

U.S. g.p.m.

Imp. g.p.m.

80

120
80

160

200

120

240

160

280

200

240
DN

6SD
19/1
4

300

1000

6SD 19

H
ft

CALPEDA

800

11
200

600
8
7

400
5
100
4
200
2

0
0
0

m3/h
Q l/min
200
l/s

20

400

30

40

50
800

600

60
%

60
1000

12

70

3.93.110.21

16

1
15

5
15

Pst
3
kW

40
Pst
20
0

Q m3/h

20

P2 Rated motor power output

50

60

72.368

3~

6SD 19/2-60
6SD 19/4-60
6SD 19/5-60
6SD 19/7-60
6SD 19/8-60
6SD 19/11-60
6SD 19/14-60

40

30

70

n 3450 rpm

P2

kW

HP

5,5
11
15
18,5
22
30
37 *

7,5
15
20
25
30
40
50 *

m /h

12

18

24

30

36

42

48

54

l/min

100

200

300

400

500

600

700

800

900 1000 1100

44
88
110
153
177
244
310

43
86
107
149
172
237
300

41
82
103
144
165
228
288

39
79
98
137
157
216
275

37
74
92
129
148
203
257

34
68
85
119
135
187
237

31
61
75
106
121
166
212

27
51
65
91
104
142
183

21
41
52
73
83
115
147

H
m

* = Franklin motor

H Total head in m

60

15
29
37
51
60
82
104

66

8
16
20
28
32
45
57

Tolerances according to ISO 9906, annex A

278

DN

L
mm

542
760
870
G3
ISO 228 1088
1197
1525
1853

kg
58,5
72
81
98
117
140
196

6SD 20 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights

250

U.S. g.p.m.

Imp. g.p.m.

100

200

300

100

200

6SD 20

6SD
20/1
0

800
H
ft

DN

700

200
CALPEDA

600
8
500

150
6

400
5

100
300

4
3

200
50

2
100

0
0

l/s

20

m3/h
l/min

60

40
400

800
8

60
%

12

80

16

20

1
15

5
15

Pst
4
kW
Pst

20

Q m 3/h

3.93.110.21

1200

40

40

20

72.369

60

80

36
Q

3~

6SD 20/2-60
6SD 20/3-60
6SD 20/4-60
6SD 20/5-60
6SD 20/6-60
6SD 20/8-60
6SD 20/10-60
P2 Rated motor power output

n 3450 rpm

P2

kW

HP

7,5
11
15
18,5
22
30
37 *

10
15
20
25
30
40
50 *

m /h

12

18

24

30

36

42

48

54

l/min

200

300

400

500

600

700

800

900 1000 1100 1200 1300

45
67
88
112
135
181
226

44
66
87
109
132
177
222

42
64
84
106
129
171
216

41
62
82
103
122
166
208

40
59
78
98
112
158
198

37
56
73
93
113
149
189

34
51
68
86
104
137
173

30
46
61
77
93
123
155

H
m

* = Franklin motor

H Total head in m

60

26
39
51
65
79
105
132

66

20
31
40
51
63
84
106

72

15
22
30
38
45
60
76

78

9
13
18
23
27
36
46

Tolerances according to ISO 9906, annex A

279

DN

L
mm

542
651
760
G3
ISO 228 870
979
1197
1416

kg
62
69,5
80
94
112
132
152

SDX 60 Hz

Submersible borehole pumps for 6 and 8 wells


Construction
Submersible motor pumps for deep wells of 6 (DN 150 mm)
and 8 (DN 200 mm), with external jacket and stages in
stainless steel AISI 304 or AISI 316.
Impellers
Radial impellers
6SDX 13-18-27

Mixed flow impellers


6SDX 45-60, 8SDX 78-97

Connection: Screwed connection ISO 228


Delivery casing with built-in non-return valve.
6 pumps with stainless steel external jacket and suction
lantern as one piece only.

Applications
For
For
For
For

water supply.
civil and industrial applications.
fire fighting applications.
irrigation.

Operating conditions
Liquid temperature up to 25 C.
Max. sand quantity into the water: 50 g/m3.
Continuous duty.

Direction of rotation: anticlockwise as seen from the


delivery casing

6, 8, 10 Rewindable motor CS series


2-pole induction motor, 60 Hz (n = 3450 rpm).
With water wetted winding in rewindable execution.
Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- three-phase 220 V; 380 V; 220/380 V; 380/660 V.
Voltage tolerance : 5%.
Recommended type of starting for powers from 7.5 kW:
star/delta, soft start, impedance starting, autotransformer.
Motor
6

Materiales
Components
External jacket
Suction lantern
Upper cover
Strainer
Delivery casing
Valve set
O-ring valve
Shaft
Coupling set
Diffuser
Impeller
Stage casing
Wear ring
Bearing bush
Cable guard
Screws

6SDX
6SDXL
Cr-Ni steel
Cr-Ni-Mo steel
AISI 304
AISI 316L
Cr-Ni-Mo steel AISI 316

8SDXL
Cr-Ni-Mo steel
AISI 316
-

Cr-Ni-Mo steel
AISI 316
Cr-Ni-Mo steel
Cr-Ni-Mo steel
AISI 316
AISI 329
Cr-Ni-Mo steel AISI 316/329
Cr-Ni-Mo steel
AISI 316L

Motor 380V - 60Hz - 3 ~


6CS 4 26
kW
6CS
30
kW
8CS 30 - 51
kW
8CS 55 66 kW
8CS
75
kW
10CS 75 - 92
10CS 110 - 132

Teflon (PTFE)
NBR
Cr-Ni-Mo steel
AISI 316

kW
kW

Section
3 + 1 x 6 mm2
3 + 1 x 10 mm2
3 + 1 x 16 mm2
3 + 1 x 25 mm2
3 + 1 x 35 mm2
3 + 1 x 35 mm2
3 + 1 x 70 mm2

Length
3,5 m
3,5 m
4 m
4 m
4 m
4
4

m
m

Special features on request


- Other voltages.
- Other temperatures.

CS Motor
Components
External frame
Supports
Shaft
Thrust bearing
Bushings

10

Insulation PVC coated wire for 6-8-10 motors.


Protection IP 68.

Cable

NBR

Cr-Ni steel
AISI 304

Max. Liquid Cooling


Max. starts
temperature minimum flow velocity
per hour
25 C
0,20 m/s for 4 15 kW
15
0,50 m/s for 18,5 30 kW
25 C
0,20 m/s for 30 51 kW
15
0,50 m/s for 55 75 kW
25 C
0,50 m/s
10

Designation

6, 8, 10
Cr-Ni steel AISI 304 (Fe P01 plate motor 10)
GJL 200 EN 1561
Hardened and tempered Cr steel AISI 420
Oscillation pads
Graphite (Bronze for 8 motor of 51-59-66 kW)

280

of the well in inches


Series
Cr-Ni-Mo steel AISI 316 construction
Stage identification
Number of stages
Frequency 60 Hz

6 SDX L 13 / 17 60

SDX 60 Hz

Submersible borehole pumps for 6 and 8 wells

Coverage charts n = 3450 rpm


10

U.S. g.p.m.
10

30

20
20

Imp. g.p.m.

40

50

30

40

100
50

200
100

300
200

500

400

800

400

300

500

700

700
2000
500

400

ft
1000

300

8SDXL 78

200

6SDX(L) 13

500

6SDX(L)
18

100

400

6SDX(L)
27

6SDX(L)
45

50

300

8
SDXL
97

6
SDX
(L)
60

200

40
100

30

20
50
40
10

30

20
5

m 3/h

40

50

Q l/min

10
100

150

20
200

300

30
400

500

40

50

100
1000

150
2000

200
3000
72.1161-60Hz

37

281

6SDX 13 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


500

U.S. g.p.m. 20

40

60

80

28

1600
ft

6SDX(L) 13

26

22

1200

19

300

DN

1400

n 3450 rpm

24

400

100

1000

17

Hm

15

800

13

200

11

600

400
100

200

0 Q m3/h

10

15

20

25

135

HP/stg
1,0
kW/stg

0,9

14

0,8
0,7
0,6

Q m3/h

14

(%)

Q m3/h

3~

6SDX 13/5-60
6SDX 13/8-60
6SDX 13/11-60
6SDX 13/13-60
6SDX 13/15-60
6SDX 13/17-60
6SDX 13/19-60
6SDX 13/22-60
6SDX 13/24-60
6SDX 13/26-60
6SDX 13/28-60

n 3450 rpm

P2

- 6SDXL 13/5-60
- 6SDXL 13/8-60
- 6SDXL 13/11-60
- 6SDXL 13/13-60
- 6SDXL 13/15-60
- 6SDXL 13/17-60
- 6SDXL 13/19-60
- 6SDXL 13/22-60
- 6SDXL 13/24-60
- 6SDXL 13/26-60
- 6SDXL 13/28-60

P2 Rated motor power output

kW

HP

4
5.5
7.5
11
11
11
15
15
18.5
18.5
18.5

5.5
7.5
10
15
15
15
20
20
25
25
25

m /h

l/min

H
m

85
135
185
220
253,5
288
321
371
405
440
472

10

12

14

16

18

21

33,3 66,6 100 133

166

200

233

266

300

350

75
120
165
195
223
255
285
330
360
390
420

72
115
159
188
216
245
275
316
345
375
403

69 63,3 56,5 47,5 30


78
110 102 90
50
150 140 125 108 70
178 165 149 126 85
205 190 170 146 96
232 215 195 166 110
260 240 216 168 123
300 280 250 215 142
329 305 274 235 156
355 330 296 254 169
383 355 320 275 182

78
80
82
130 128 123
180 175 170
212 206,5 200
245 239 232
278 270 262
310 302 293
360 349 340
391 380 370
425 411 400
458 445 432

Tolerances according to ISO 9906, annex A

282

DN

Rp
2 1/2

6SDX

mm

kg

356
446
536
596
656
716
776
866
926
986
1048

10.5
13
15
16.5
18
19.5
21
23
24.5
26
28

6SDX 18 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


500

0 U.S. g.p.m. 20

40

60

80

100

120

140

1600
ft

28

6SDX(L) 18

26

400

DN

1400

n 3450 rpm

22

1200
18

300

1000

Hm

15

800

13

200

11

600

9
7

100

400

200

0 Q m3/h

10

15

20

25

30

35

0
135

HP/stg

1,7
kW/stg

1,5

1,3

14

1,1
0,9
0,7

Q m3/h

14

(%)

Q m3/h

3~

m3/h

6SDX 18/3-60 - 6SDXL 18/3-60


6SDX 18/5-60 - 6SDXL 18/5-60
6SDX 18/7-60 - 6SDXL 18/7-60
6SDX 18/9-60 - 6SDXL 18/9-60
6SDX 18/11-60 - 6SDXL 18/11-60
6SDX 18/13-60 - 6SDXL 18/13-60
6SDX 18/15-60 - 6SDXL 18/15-60
6SDX 18/18-60 - 6SDXL 18/18-60
6SDX 18/22-60 - 6SDXL 18/22-60
6SDX 18/26-60 - 6SDXL 18/26-60
6SDX 18/28-60 - 6SDXL 18/28-60
P2 Rated motor power output

n 3450 1/min

P2

kW

HP

4
5.5
7.5
11
11
15
15
18.5
22
30
30

5.5
7.5
10
15
15
20
20
25
30
40
40

l/min

H
m

0
0
51
85
120
154
190
223,5
254
310
379
448
481

12

15

18

21

24

27

30

66,6 150

200

250

300

350

400 450

500

49,5
80
114
146
180
211
245
293
359
425
456

46,5
79,5
110
141
173
205
238
283
348
410
442

45
75
106
135
165
196
228
270
331
393
423

42
70
100
128
156
185
213
256
312
370
398

38
65
90
116
143
170
195
235
286
339
365

34
58
80
104
128
150
174
210
255
300
325

22
38
52
68
83,5
99
113
136
165
197
211

50
82,5
119
150
184
220
251
302
370
440
471

Tolerances according to ISO 9906, annex A

283

29
49
69
87
108
126
148
175
215
255
273

32

DN

6SDX

533

mm

kg

16,5
29
40
52,5
65
76,5
89
106
130
152
166

318.5
393.5
468.5
543.5
618.5
693.5
768.5
881
1031
1181
1256

9
11
12.5
14
16
17.5
19
21.5
25
28
30

Rp
2 1/2

37

6SDX 27 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


450

0 U.S. g.p.m. 40

80

120

160

240

1400

6SDX(L) 27

23

400

200

ft

n 3450 rpm

350

DN

1200

19

1000

300
15
14

800

Hm

250

200

11

600
9

150
7

400

100
4

0 Q m3/h

10

20

30

40

50

60

kW/stg

200

50

135

HP/stg
2,5
2,3
2,1
1,9
1,7
1,5
1,3

Q m3/h

14

(%)

14

Q m3/h

3~

m3/h

6SDX 27/3-60
6SDX 27/4-60
6SDX 27/7-60
6SDX 27/9-60
6SDX 27/11-60
6SDX 27/14-60
6SDX 27/15-60
6SDX 27/19-60
6SDX 27/23-60

n 3450 1/min

P2

- 6SDXL 27/3-60
- 6SDXL 27/4-60
- 6SDXL 27/7-60
- 6SDXL 27/9-60
- 6SDXL 27/11-60
- 6SDXL 27/14-60
- 6SDXL 27/15-60
- 6SDXL 27/19-60
- 6SDXL 27/23-60

P2 Rated motor power output

kW

HP

5.5
7.5
11
15
18.5
22
30
30
37 *

7.5
10
15
20
25
30
40
40
50 *

* = Franklin motor

l/min

H
m

12

16

20

24

28

32

36

40

45

50

100

200

266

333

400

466 533

600

666

750

833

52 51,5 50,5
71
70 69,5
125 123,5 120
160 160 154
195 192 190
249 248 240
266 262 258
338 333 327
409 403 395

50
68
117
150
185
235
250
316
385

49 46,5 42 39,5
65 61,5 54
52
112 108 100 92,5
145 138 130 119
179 169 158 145
227 215 200 185
240 230 215 198
305 290 270 250
370 350 330 303

Tolerances according to ISO 9906, annex A

284

35
30
25
15
48
40
31 21,5
82
70
55
36
105
71
91
49
130 112 87
60
165 142 110 75
178 153,5 120 80
225 192 150 100
270 235 180 120

DN

Rp
3

6SDX

mm

kg

365.5
412
551.5
644.5
737.5
877
923.5
1109.5
1295.5

10.5
11.5
14.5
16.5
18.5
21.5
22
26
30

6SDX 45 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


350

0 U.S. g.p.m.
40

80

120

160

200

240

280

320

ft

6SDX(L) 45

15

300

250

1000

n 3450 rpm

12

DN

800

10

200

Hm

150

600

400

100

4
3

50

0 Q m3/h 10

20

30

40

50

60

70

80

kW/stg

200

135

HP/stg
3,7
3,3
2,9
2,5
2,1
1,7
1,3

Q m3/h

14

(%)

14

Q m3/h

3~

m3/h

6SDX 45/2-60
6SDX 45/3-60
6SDX 45/4-60
6SDX 45/5-60
6SDX 45/6-60
6SDX 45/7-60
6SDX 45/9-60
6SDX 45/10-60
6SDX 45/12-60
6SDX 45/15-60

37

n 3450 1/min

P2

- 6SDXL 45/2-60
- 6SDXL 45/3-60
- 6SDXL 45/4-60
- 6SDXL 45/5-60
- 6SDXL 45/6-60
- 6SDXL 45/7-60
- 6SDXL 45/9-60
- 6SDXL 45/10-60
- 6SDXL 45/12-60
- 6SDXL 45/15-60

P2 Rated motor power output

kW

HP

5.5
7.5
11
15
15
18.5
22
30
30
37 *

7.5
10
15
20
20
25
30
40
40
50 *

* = Franklin motor

10

18

l/min

166

41,5
62
82
103
125
145
186
206
249
310

40
59,5
79
99
118
137
177
195
235
293

24

30

36

42

48

54

300

400

500

600

700

800

900 1000 1100 1183

38
56,5
75
94
112
130
169
187
224
280

32
36,5 34
52
49
54
65
71,5 69
86
80
90
108 103 98
125 120 112
160 153,5 145
179 170 160
215 205 192
269 255 240

66

71

30
28
25
22
20 16,5
46
42 38,5 35 29,5 24
60 56,5 51
45
39 31,5
76
70 63,5 56,5 49
40
90 83,5 76
68
58 48,5
89
105 98
79
68
56
135 125 113 100 87
71
150 139 126 112 86,5 80
180 168 151 134 116 96
225 209 190 169 145 120

Tolerances according to ISO 9906, annex A

285

60

DN

Rp
3

6SDX

mm

kg

365.5
458.5
551.5
645
737.5
830.5
1016.5
1109.5
1295.5
1574

11
13.5
16
18
20.5
22.5
27
29.5
34
41

6SDX 60 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


U.S. g.p.m. 80

160

240

320

15

300

400

6SDX(L) 60

14

ft
1000
DN

n 3450 rpm

250

800

12

10

200

Hm

600

150

7
6

400

100

4
3

50

10

20

30

40

50

60

70

80

0
100
HP/stg

90

135

3,9
3,7
3,5
3,3
3,1
2,9
2,7

kW/stg

200

Q m3/h

14

(%)

14

Q m3/h

3~

m3/h

6SDX 60/2-60
6SDX 60/3-60
6SDX 60/4-60
6SDX 60/5-60
6SDX 60/6-60
6SDX 60/7-60
6SDX 60/8-60
6SDX 60/9-60
6SDX 60/10-60
6SDX 60/12-60
6SDX 60/14-60
6SDX 60/15-60

n 3450 1/min

P2

- 6SDXL 60/2-60
- 6SDXL 60/3-60
- 6SDXL 60/4-60
- 6SDXL 60/5-60
- 6SDXL 60/6-60
- 6SDXL 60/7-60
- 6SDXL 60/8-60
- 6SDXL 60/9-60
- 6SDXL 60/10-60
- 6SDXL 60/12-60
- 6SDXL 60/14-60
- 6SDXL 60/15-60

P2 Rated motor power output

kW

HP

5.5
7.5
11
15
15
18.5
22
22
30
30
37 *
37 *

7.5
10
15
20
20
25
30
30
40
40
50 *
50 *

* = Franklin motor

l/min

H
m

14

21

28

35

42

49

56

233

40
60
80
101
120
140
160
180
201
241
280
301

39,5
58
76,5
96,5
115
134
153
172
190
230
268
287

350

466

583

700

816

933 1050 1166 1283 1400

38
55
75
91,5
110
129
148
166
185
220
265
273

29 25,5 23,5
36,5 33,5 31
53,5 50 46,5 42 39,5 35
70 66,5 61,5 56,5 51,5 46,5
58
65
70
78
89,5 82
78 69,5
85
105 99,5 92
80
122 116 109 100 90
140 132 122 112 103 92
158 149 139 127 116 104
176 166 152 140 129 115
210 198 183 170 155 137
245 230 215 197 180 160
262 248 230 210 191 170

Tolerances according to ISO 9906, annex A

286

63

70

20
30
40
50
60
70
80
90
100
120
140
150

77

17,5
26,5
35
43,5
52
60
68
78
86,5
104
120
129

87

15
21,5
29
35,5
42,5
50
57,5
65
71
86,5
100
107

DN

Rp
3

6SDX

mm

kg

365.5
458.5
551.5
645
737.5
830.5
923.5
1016.5
1109.5
1295.5
1481.5
1574

11.5
13.5
16
18
20.5
23
25
27
30
34
39
41

8SDXL 78 60 Hz

Submersible borehole pumps


for 8 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


550

U.S. gpm

100

150

200

250

300

350

400

16

550

1800

DN

1700
ft
1600

n 3450 rpm

15

400

500

8SDXL 78

500

450

450

1500

14

1400

13

1300

12

1200

11

1100

10

1000

900

300

250

800

700

200

150

100

600

500

400

300

200

50

170,5

100

m3/h 20

30

40

50

60

70

80

90

100

110

120

130

(%)

80

kW/stg

60
6

8"

8")
8(
19
6")

2(
19

8")
5 ( ")
19
6

7(
18

100

6.5

40

kW/stg
5.5
5

188

(%)

6"

Hm

350

20

Q m3/h 20

30

40

50

60

80

90

100

3~

110

0
130

120

n 3450

1/min

P2
m /h
3

8SDXL 78/2-60
8SDXL 78/3-60
8SDXL 78/4-60
8SDXL 78/5-60
8SDXL 78/6-60
8SDXL 78/7-60
8SDXL 78/8-60
8SDXL 78/9-60
8SDXL 78/10-60
8SDXL 78/11-60
8SDXL 78/12-60
8SDXL 78/13-60
8SDXL 78/14-60
8SDXL 78/15-60
8SDXL 78/16-60

70

kW

HP

11
18.5
22
30
37
37
45
55
55
75
75
75
92
92
92

15
25
30
40
50
50
60
75
75
100
100
100
125
125
125

P2 Rated motor power output

l/min

H
m

20

30

40

50

333

500

666

833

1000 1166 1333 1500 1666 1833 2000

58
86
114
145
172
201
230
269
298
330
359
389
419
449
479

58
85
113
143
170
198
228
265
295
322
352
381
411
440
470

56 53,5
83,5 80
110 105
140 133
166 159
193 185
220 211
257 247
286 275
316 302
343 330
372 358
400 385
430 412
459 440

50
75
99
126
150
175
200
235
260
287
313
340
367
391
418

35
39
41
45
48
30
25
70 66,5 62 57,5 50
45
39
68
93,5 88 81,5 75
59
50
120 111 104 96,5 86,5 76,5 65
141 132 123 113 101 89 76,5
165 155 144 133 120 105 89
190 178 165 152 137 120 99,5
221 208 192 180 162 141 120
246 230 215 199 180 159 133
271 255 237 220 199,5 175 149
296 278 259 239 217 190 160
320 300 280 260 235 207 175
346 325 300 280 251 220 189
370 347 322 300 270 239 200
395 370 345 320 288 252 215

60

Tolerances according to ISO 9906, annex A

287

70

80

90

100 110

120

DN

CS
mm
145
6"

Rp
5

191
8"

240
10"

8SDX

mm

kg

644
770
896
1022
1148
1274
1400
1531
1657
1783
1909
2035
2161
2287
2413

31.5
36.5
41.5
46
51
56
61
67
72
77
82
87
92
97
101.5

37

8SDXL 97 60 Hz

Submersible borehole pumps


for 8 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. gpm 100

150

200

250

300

350

400

450

500

550

600

650

700

550

8SDXL 97

16

500

15

450

1800
ft
1700
1600

n 3450 rpm

1500

14

1400

13

400

1300

12

1200

11

350

DN

Hm

1100

10

1000

300

900
8

250

800
7

700

600

150

100

170,5

500
400

300

200

50

100

Q m3/h

30

40

50

60

70

80

90

100 110 120 130 140 150 160


100

(%)

kW/stg

60

kW/stg

40

8"-10"

8")
8(
19
6")

2(
19

8")
5 ( ")
19
6

7(
18

80

8
7

188

(%)

6"

200

20

5
0

Q m3/h

30

3~

8SDXL 97/2-60
8SDXL 97/3-60
8SDXL 97/4-60
8SDXL 97/5-60
8SDXL 97/6-60
8SDXL 97/7-60
8SDXL 97/8-60
8SDXL 97/9-60
8SDXL 97/10-60
8SDXL 97/11-60
8SDXL 97/12-60
8SDXL 97/13-60
8SDXL 97/14-60
8SDXL 97/15-60
8SDXL 97/16-60

40

50

60

70

90

0
100 110 120 130 140 150 160

P2

m3 /h
kW

HP

15
22
30
37
37
45
55
75
75
75
92
92
92
110
110

20
30
40
50
50
60
75
100
100
100
125
125
125
150
150

P2 Rated motor power output

80

l/min

H
m

n 3450

1/min

30

45

500

750 1000 1250 1500 1750 2000 2250 2500

57
60
60
90 83,5
90
122 120 114
150 149,5 140
181 180 169
213 210 198
250 249 232
283 280 262
315 310 292
346 341 320
378 372 350
410 405 380
440 435 410
472 467 439
504 498 468

60

75

90

105

120

42 39,5 35
48
52
77,5 70 62,5 58 49,5
69
79
85
95
104
129 116 106 96,5 83
154 139,5 127 115 100
180 163,5 149 135 117
215 195 176 160 140
240 219 200 181 159
269 243,5 220 200 178
295 269 242 220 194
320 290 265 241 211
350 317 289 262 230
375 340 310 282 248
401 365 330 302 265
430 390 352 322 280

Tolerances according to ISO 9906, annex A

288

135

28
40
55
67
80
93,5
115
130
143
159
171
188
200
215
230

150

19
27
39
46
55
68
83
95
105
115
125
137
148
158
169

DN

CS
mm
145
6"

Rp

191
8"

240
10"

L
mm

644
770
896
1022
1148
1274
1405
1531
1657
1783
1909
2035
2161
2287
2413

8SDX
kg

31.5
36.5
41.5
46
51
56
62.5
67
72
77
82
87
92
97
101.5

SDS

60 Hz

Submersible borehole pumps for 6, 8 and 10 wells


Construction
Submersible motor pumps for deep wells of 6 (DN 150 mm),
8 (DN 200 mm) and 10 (DN 250 mm).
Impellers: - mixed flow impellers.
Connection: - screwed connection ISO 228 for 6SDS;
- flange with counter-flange for welding for 8SDS
and 10SDS
Delivery casing with built-in non-return valve.

Applications
For
For
For
For

water supply.
civil and industrial applications.
fire fighting applications.
irrigation.

Operating conditions
Liquid temperature up to 25 C.
Max. sand quantity into the water: 100 g/m3.
Continuous duty.

6, 8, 10 Rewindable motor CS series


2-pole induction motor, 60 Hz (n = 3450 rpm).
With water wetted winding in rewindable execution.
Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- three-phase 220 V; 380 V; 220/380 V; 380/660 V.
Voltage tolerance : 5%.
Recommended type of starting for powers from 7.5 kW:
star/delta, soft start, impedance starting, autotransformer.
Motor
6
8
10

Max. Liquid Cooling


temperature minimum flow velocity
25 C
0,20 m/s for 4 15 kW
0,50 m/s for 18,5 30 kW
25 C
0,20 m/s for 30 51 kW
0,50 m/s for 55 75 kW
25 C
0,50 m/s

Max. starts
per hour
15
15
10

Insulation PVC coated wire for 6-8-10 motors.


Protection IP 68.

Materials

Pump

Components
Stage casing
Diffuser
Impeller
Wear ring
Shaft

Shaft sleeve
Delivery casing
Suction lantern
Bearing bush
Strainer
Screws

Cable
Part Nr.
25.02
26.00
28.00

6, 8, 10SDS

B-6, B-8, B-10SDS

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Rubber (Bronze for 10SDS 190-280)


6SDS e 8SDS:
Steel AISI F51duplex
Cr-Ni-Mo steel
AISI 316
10SDS
Cr steel AISI 420
64.08 Brass with chromate surface treatment (only for 10SDS)

64.00

12.01
32.02
12.03-12.30
15.50

Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Rubber
Cr-Ni steel AISI 304
Cr-Ni steel AISI 304

Motor 380V - 60Hz - 3 ~


6CS 4 26
kW
6CS
30
kW
8CS 30 - 51
kW
8CS 55 66 kW
8CS
75
kW
10CS 75 - 92
10CS 110 - 132
10CS 150

kW
kW
kW

Section
3 + 1 x 6 mm2
3 + 1 x 16 mm2
3 + 1 x 16 mm2
3 + 1 x 25 mm2
3 + 1 x 35 mm2
3 + 1 x 35 mm2
3 + 1 x 70 mm2
3 + 1 x 95 mm2

Length
3,5 m
3,5 m
4 m
4 m
4 m
4
4
4

m
m
m

Special features on request


- Other voltages.
- Other temperatures.

38

Designazione

CS
Motor

10 B SDS 190 / 6 - 60
External frame
Shaft
Thrust bearing
Bearing bush

Cr-Ni steel AISI 304 (Fe P01 plate motor 10)


Cr steel AISI 420
Cr-Ni-Mo steel
Hardened and tempered
AISI 316
Oscillation pads
Graphite (Bronze for 8 motor of 51 - 59 - 66 kW)

289

of the well in inches


Bronze construction (on request)
Series
Stage identification
Number of stages
Frequency 60 Hz

SDS

60 Hz Submersible borehole pumps for 6, 8 and 10 wells

Coverage charts n = 3450 rpm


50

100
50

40

U.S. g.p.m.
100

200

300

Imp. g.p.m.

200

500

400

400

300

1000
500

1500
1000

2000
1500

600
500

1500

SDS

400
300

1000

10SDS 160

H
ft

200

8SDS 70

500

8SDS 100

6SDS 32

400

100

300

6SDS
42

10SDS
190

8SDS
150

6SDS 58

200

10SDS 280

50
40
100

30

20
50
40
10

30

20

6
10

20

3
Q m /h

200

l/min

300

30
400

500

40

50

200

100
2000

1000

3000

300
4000

5000

400

500
8000
72.826.N

290

6SDS 32 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


U.S. g.p.m.

0
0

Imp. g.p.m.

100

50

150

200
150

100

400

200

6SDS 32
DN

1200
350

19

18

ft

17

300

16
15

250

14

1000

CALPEDA

800

13
12
11

200

10

600

9
150

8
7

400

6
100

5
4
200

50

3.93.065/1

3
15

9
14

m 3/h 10
0
0 Q l/min
200
0

80

20

30

400

l/s

600

40

50
800
12

70
%

Pst
3

50

kW
2

Pst

40
30
20

0 Q m 3/h 10

30

B-6SDS 32/3-60
B-6SDS 32/4-60
B-6SDS 32/5-60
B-6SDS 32/6-60
B-6SDS 32/7-60
B-6SDS 32/8-60
B-6SDS 32/9-60
B-6SDS 32/10-60
B-6SDS 32/11-60
B-6SDS 32/12-60
B-6SDS 32/13-60
B-6SDS 32/14-60
B-6SDS 32/15-60
B-6SDS 32/16-60
B-6SDS 32/17-60
B-6SDS 32/18-60
B-6SDS 32/19-60

P2 Rated motor power output

40

50

m /h
3

kW

HP

7,5
11
11
13
15
18,5
18,5
22
22
26
26
30
30
37 *
37 *
45 *
45 *

10
15
15
17,5
20
25
25
30
30
35
35
40
40
50 *
50 *
60 *
60 *

l/min

H
m

* = Franklin motor

72.1048

Power
P2

3~

6SDS 32/3-60
6SDS 32/4-60
6SDS 32/5-60
6SDS 32/6-60
6SDS 32/7-60
6SDS 32/8-60
6SDS 32/9-60
6SDS 32/10-60
6SDS 32/11-60
6SDS 32/12-60
6SDS 32/13-60
6SDS 32/14-60
6SDS 32/15-60
6SDS 32/16-60
6SDS 32/17-60
6SDS 32/18-60
6SDS 32/19-60

20

n 3450 rpm
0
0
66
88
110
132
154
176
198
220
242
264
286
308
330
352
374
396
418

14,4

24

30

36

42

46

50

240

400

500

600

700

766

833

57,5 52,5
76,5 70
96 87,5
115 105
134 123
153 140
172 158
191 175
210 193
229 210
248 228
267 245
287 263
306 280
325 298
344 315
363 333

48
64
80
96
112
128
144
160
176
192
208
224
240
256
272
288
304

43
36 31,5 26,5
35
57 48,5 42
71 60,5 52,5 44
53
63
85
73
99,5 85 73,5 62
84 70,5
114
97
128 109 94,5 79
88
142 121 105
97
156 133 115
170 145 126 106
185 157 136 114
199 169 147 123
213 181 157 132
227 194 168 141
241 206 178 149
256 218 189 159
270 230 200 167

H Total head in m

Tolerances according to ISO 9906, annex A

291

DN

mm

mm

kg

kg

686
788
890
992
1094
1196
1298
1400
1502
1604
1706
1808
1910
2012
2114
2216
2318

30,5
35,6
41
46
52,3
57
62,5
68,5
72,5
77,5
84
89
94,2
100
105
111
116

35,5
41,6
49
55
62,3
68
74,5
81,5
86,5
93,5
101
108
112
119
125
132
139

145
6
G3
ISO 228

137
6

6SDS B-6SDS

38

6SDS 42 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


U.S. g.p.m.

100

150

0 Imp. g.p.m. 50

250

200

100

200

150

350

6SDS 42
DN

1000

300

15

14

ft
CALPEDA

13

250

800

12

11

200

10
600

150

7
400

6
5

100

4
3
50

200

3.93.065/1

2
3
15

9
14

0 0
3
/h 10
Q m
l/min 200
0
0

l/s 2

20

30

40

400
4

50
800

600

10

70

14

12

60
1000
16

18
4

60
%

Pst
3

Pst

kW
2

50
40

0 Q m 3/h 10

20

B-6SDS 42/2-60
B-6SDS 42/3-60
B-6SDS 42/4-60
B-6SDS 42/5-60
B-6SDS 42/6-60
B-6SDS 42/7-60
B-6SDS 42/8-60
B-6SDS 42/9-60
B-6SDS 42/10-60
B-6SDS 42/11-60
B-6SDS 42/12-60
B-6SDS 42/13-60
B-6SDS 42/14-60
B-6SDS 42/15-60

P2 Rated motor power output

50

40

Power
P2

3~

6SDS 42/2-60
6SDS 42/3-60
6SDS 42/4-60
6SDS 42/5-60
6SDS 42/6-60
6SDS 42/7-60
6SDS 42/8-60
6SDS 42/9-60
6SDS 42/10-60
6SDS 42/11-60
6SDS 42/12-60
6SDS 42/13-60
6SDS 42/14-60
6SDS 42/15-60

30

kW

HP

7,5
11
11
15
18,5
18,5
22
26
30
30
37 *
37 *
45 *
45 *

10
15
15
20
25
25
30
35
40
40
50 *
50 *
60 *
60 *

72.1050

60

Q
m /h
3

l/min

H
m

* = Franklin motor

n 3450 rpm
0

21

27

32

37

42

47

52

57

350

450

533

616

700

783

866

950 1050

46
70
93
116
140
163
186
209
233
256
280
302
326
349

40
60
80
100
120
140
160
180
200
220
240
260
280
300

38 36,5 34,5 32 29,5 26,5 23,5 19


29
35
48 44,5 40
52
57,5 55
47 38,5
53
69 64,5 59
76,5 73
95,5 91,5 86,5 80,5 74 66,5 58,5 48
70 57,5
80
115 110 104 96,5 89
67
82
93
134 128 121 113 103
153 146 138 129 118 106 93,5 77
172 165 156 145 133 120 105 86,5
96
191 183 173 161 148 133 117
210 201 190 177 163 146 129 105
229 219 208 193 177 159 140 115
248 238 225 209 192 173 152 125
267 256 242 225 207 186 164 134
286 274 259 241 222 199 175 144

H Total head in m

63

Tolerances according to ISO 9906, annex A

292

DN

mm

mm

kg

kg

584
686
788
890
992
1094
1196
1298
1400
1502
1604
1706
1808
1910

25,5
31,6
36
40,3
47
50,5
55,5
62,5
69
74
79,2
83,2
91,4
96,4

29,5
36,6
42
48,3
59
65,5
66,5
74,5
81
86
94,2
99,2
106
113

145
6

G3
ISO 228

137
6

6SDS B-6SDS

6SDS 58 60 Hz

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0

50
50

U.S. g.p.m.

100
100

250

Imp. g.p.m.

300

200

350

250

400

300

350

250

800

6SDS 58

DN

700
200

14

ft
600

13

CALPEDA

12
11

150

500

10
L

400

8
7

100

300

6
5

200

4
50

3.93.065/1

100

1
0

0 Q m 3/h
l/min
0
0

40

60
1000

500
5

l/s

80

20
10

15

80
1500
20

25
5
4
Pst
3
kW
2

Pst

50
0 Q m 3/h

20

60

Power
P2

3~

6SDS 58/1-60
6SDS 58/2-60
6SDS 58/3-60
6SDS 58/4-60
6SDS 58/5-60
6SDS 58/6-60
6SDS 58/7-60
6SDS 58/8-60
6SDS 58/9-60
6SDS 58/10-60
6SDS 58/11-60
6SDS 58/12-60
6SDS 58/13-60
6SDS 58/14-60

40

B-6SDS 58/1-60
B-6SDS 58/2-60
B-6SDS 58/3-60
B-6SDS 58/4-60
B-6SDS 58/5-60
B-6SDS 58/6-60
B-6SDS 58/7-60
B-6SDS 58/8-60
B-6SDS 58/9-60
B-6SDS 58/10-60
B-6SDS 58/11-60
B-6SDS 58/12-60
B-6SDS 58/13-60
B-6SDS 58/14-60

P2 Rated motor power output

kW

HP

3,7
5,5
11
11
15
18,5
22
22
26
30
37 *
37 *
45 *
45 *

5
7,5
15
15
20
25
30
30
35
40
50 *
50 *
60 *
60 *

80

100

72.1051

Q
m /h
3

l/min

H
m

* = Franklin motor

100

70
%
60

40

3
15

9
14

n 3450 rpm
0
0
18
36
54
72
90
108
126
144
162
180
198
216
234
252

36

48

54

60

66

72

78

84

600

800

900 1000 1100 1200 1300 1400 1600

8,5
12 11,5 10,5 9,5
13
14,5 13
29 26,5 26 24,5 23 21,5 19,5 17,5
40 38,5 36,5 35 32,5 29,5 26,5
43
35
39
49 46,5 43
51
57,5 53
44
49
54
58
61
64
66
72
53
59
65
70
73
77
86,5 79
101 92,5 90 85,5 81 75,5 68,5 61,5
93 86,5 78,5 70,5
98
115 106 102
79
88
97
130 119 115 110 104
88
98
144 132 128 122 116 108
97
158 145 141 134 128 119 108
173 158 154 146 139 130 118 106
187 172 166 159 151 140 127 114
202 185 179 171 162 151 137 123

H Total head in m

96

6
12
18
24
30
36
42
48
54
60
66
72
78
84

Tolerances according to ISO 9906, annex A

293

DN

mm

mm

kg

kg

482
584
686
788
890
992
1094
1196
1298
1400
1502
1604
1706
1808

21,3
26,5
31,6
37
43,3
48
53,5
59,5
65
71
76,2
82,2
87,4
93,4

22,4
29,5
36,6
43
50,3
57
63,5
70,5
77
84
90,2
97,2
104
111

145
6

G4
ISO 228

137
6

6SDS B-6SDS

38

8SDS 70 60 Hz

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0
560

50

100

U.S. g.p.m.

250

100 Imp. g.p.m. 200

50

300
250

350

450

400

300

500

Counter-flange for welding.

400

350

1800

8SDS 70

14

500

1600

13

190

DN

83

12

109

1400
400

11

10

CALPEDA

40

ft

1200

m
9

300

15
168

1000

7
800
6
200

600

4
400

3.93.066.N

100
2
200

0
0

3
/h 20
Q m
l/min

40

500

60
1000
15

10

80
%

80

1500

20

0
120
2000

100
30

25

72.972.60

60
50

8
Pst
kW
6

Pst

40
30

20

Q m3 /h 20

40

8SDS 70/1-60
8SDS 70/2-60
8SDS 70/3-60
8SDS 70/4-60
8SDS 70/5-60
8SDS 70/6-60
8SDS 70/7-60
8SDS 70/8-60
8SDS 70/9-60
8SDS 70/10-60
8SDS 70/11-60
8SDS 70/12-60
8SDS 70/13-60
8SDS 70/14-60

60

Power
P2

3~

B-8SDS 70/1-60
B-8SDS 70/2-60
B-8SDS 70/3-60
B-8SDS 70/4-60
B-8SDS 70/5-60
B-8SDS 70/6-60
B-8SDS 70/7-60
B-8SDS 70/8-60
B-8SDS 70/9-60
B-8SDS 70/10-60
B-8SDS 70/11-60
B-8SDS 70/12-60
B-8SDS 70/13-60
B-8SDS 70/14-60

P2 Rated motor power output

9
19

2
19

kW

HP

7,5
15
26
30
37
45
55
59
66
75
92
92
92
110

10
20
35
40
50
60
75
80
90
100
125
125
125
150

80

100

120

n 3450 rpm

m3/h

20

40

50

l/min

333

666

833 1000 1166 1333 1500 1666 1833

38
76
114
152
190
228
266
304
342
380
418
456
494
532

35
70
105
140
175
210
245
280
315
350
385
420
455
490

32
64
96
128
160
192
224
256
288
320
352
384
416
448

30,5
61
91,5
122
153
183
214
244
275
305
336
366
397
427

H
m

H Total head in m

60

28,5
57
85,5
114
143
171
200
228
257
285
314
342
371
399

70

26,5
53
79,5
106
133
159
186
212
239
265
292
318
345
371

80

24
48
72
96
120
144
168
192
216
240
264
288
312
336

90

21,5
43
64,5
86
108
129
151
172
194
215
237
258
280
301

100

19
38
57
76
95
114
133
152
171
190
209
228
247
266

110

16
32
48
64
80
96
112
128
144
160
176
192
208
224

Tolerances according to ISO 9906, annex A

294

DN

mm

mm

kg

kg

602
734
866
998
1130
1262
1394
1526
1658
1790
1922
2054
2186
2318

38
49
60
71,5
82,5
93,5
105
116
127
138
149
160
171
182

43
55,5
68
80,5
93
106
118
131
143
156
168
181
194
206

145
6

100

191
8

240
10

8SDS B-8SDS

8SDS 100 60 Hz

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0
460

100

U.S. g.p.m.

200

100

400

500

Imp. g.p.m.

200

400

700

Counter-flange for welding.

500

1400

8SDS 100

12

400

600

DN

190
83

1200

10

1000

300

135
CALPEDA

ft

40

11

15

168

800

200

600
.

5
4
400
3

100

3.93.066.1.N

200

0
0

3
/h
40
Q m
l/min 500

l/s

80

60
1000

100

120
2000

1500

10

20

0
160

140
2500

30

40

72.970.60

16

80
%

14

60

12
Pst
10
kW
8

Pst

50
40
30

9
19

2
19

Q m3 /h

40

Power
P2

3~

8SDS 100/1-60
8SDS 100/2-60
8SDS 100/3-60
8SDS 100/4-60
8SDS 100/5-60
8SDS 100/6-60
8SDS 100/7-60
8SDS 100/8-60
8SDS 100/9-60
8SDS 100/10-60
8SDS 100/11-60
8SDS 100/12-60

80

60

B-8SDS 100/1-60
B-8SDS 100/2-60
B-8SDS 100/3-60
B-8SDS 100/4-60
B-8SDS 100/5-60
B-8SDS 100/6-60
B-8SDS 100/7-60
B-8SDS 100/8-60
B-8SDS 100/9-60
B-8SDS 100/10-60
B-8SDS 100/11-60
B-8SDS 100/12-60

P2 Rated motor power output

kW

HP

11
22
30
45
51
59
75
92
92
110
132
132

15
30
40
60
70
80
100
125
125
150
180
180

100

120

140

160

n 3450 rpm

m3/h

40

l/min

666 1000 1166 1333 1500 1666 1833 2000 2166 2500

H
m

36
73
109
146
183
220
256
293
329
366
402
440

33
66
99
132
165
198
231
264
297
330
363
396

H Total head in m

60

70

80

30,5 29,5
61
59
91,5 88,5
122 118
153 148
183 177
214 207
244 236
275 266
305 295
336 325
366 354

28,5
57
85,5
114
143
171
200
228
257
285
314
342

90

27,5
55
82,5
110
138
165
193
220
248
275
303
330

100

26,5
53
79,5
106
133
159
186
212
239
265
292
318

110

25,5
51
76,5
102
128
153
179
204
230
255
281
306

120

24
48
72
96
120
144
168
192
216
240
264
288

130

22
44
66
88
110
132
154
176
198
220
242
264

Tolerances according to ISO 9906, annex A

295

150

17
34
51
68
85
102
119
136
153
170
187
204

DN

mm

mm

kg

kg

602
734
866
998
1130
1262
1394
1526
1658
1790
1922
205

38
49
60
71,5
82,5
93,5
105
116
127
138
149
160

43
55,5
68
80,5
93
106
118
131
143
156
168
181

145
6

125

191
8

240
10

8SDS B-8SDS

38

8SDS 150 60 Hz

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0
360

100

U.S. g.p.m.

200

500

600

200 Imp. g.p.m. 400

100

700

500

900

800

600

Counter-flange for welding.


800

700

8SDS 150
DN

190

1000

300

83
135

H
.

ft

CALPEDA

40

10

800

m
9

15

200

168
L

600

7
6
5

400

100

3.93.066.1.N

200

0
0
0

3
/h 40
Q m
l/min

80

120
2000

1000

10

l/s

20

9
19

2
19

160

0
220

200
3000

30

40

50

60

72.971.60

80
%

16

60
50

14
Pst
12
kW
10

Pst

40
30

Q m3 /h 40

120

Power
P2

3~

8SDS 150/1-60
8SDS 150/2-60
8SDS 150/3-60
8SDS 150/4-60
8SDS 150/5-60
8SDS 150/6-60
8SDS 150/7-60
8SDS 150/8-60
8SDS 150/9-60
8SDS 150/10-60

80

B-8SDS 150/1-60
B-8SDS 150/2-60
B-8SDS 150/3-60
B-8SDS 150/4-60
B-8SDS 150/5-60
B-8SDS 150/6-60
B-8SDS 150/7-60
B-8SDS 150/8-60
B-8SDS 150/9-60
B-8SDS 150/10-60

P2 Rated motor power output

kW

HP

15
30
45
51
66
75
92
92
110
132

20
40
60
70
90
100
125
125
150
180

160

200

220

n 3450 rpm

m /h

l/min

H
m

33
66
100
133
166
199
233
266
299
333

1166 1500 1833 2000 2166 2333 2500 2666 3000 3416

mm

mm

kg

kg

11,5
23
34,5
46
57,5
69
80,5
92
104
115

145
6

602
734
866
998
1130
1262
1394
1526
1658
1790

38
49
60
71,5
82,5
93,5
105
116
127
138

43
55,5
68
80,5
93
106
118
131
143
156

70

26
52
78
104
130
156
182
208
234
260

H Total head in m

90

110

24,5 22,5
45
49
73,5 67,5
90
98
123 113
147 135
172 158
196 180
221 203
245 225

120

22
44
66
88
110
132
154
176
198
220

130

21,5
43
64,5
86
108
129
151
172
194
215

140

20,5
41
61,5
82
103
123
144
164
185
205

150

20
40
60
80
100
120
140
160
180
200

160

19
38
57
76
95
114
133
152
171
190

180

16
32
48
64
80
96
112
128
144
160

Tolerances according to ISO 9906, annex A

296

205

DN

191
8
125

240
10

8SDS B-8SDS

10SDS 160 60 Hz

Submersible borehole pumps for 10 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. g.p.m. 200
340

0 Imp. g.p.m.

300

200

400
300

300

500

600

400

10SD
S

700

500

800

600

Counter-flange for welding.

700

1000

10SDS 160

160/5

H
ft
DN

235

107

800

179

CALPEDA

200
600
3

15
210
L

400

200

100 12
10
8
NPSH
6
m

3.93.067.N

4
0

0
0
0

m3/h 40

Q l/min
l/s

80

120
2000

1000
10

20

160

200

40

3
26

3
25

3000

30

50
32

75
70
%

Pst

65

28
Pst
24
kW
20

60
55

Q m3/h

40

80

120

160

72.347

200

16

38
Power
P2

3~

10SDS 160/1-60
10SDS 160/2-60
10SDS 160/3-60
10SDS 160/4-60
10SDS 160/5-60

B-10SDS 160/1-60
B-10SDS 160/2-60
B-10SDS 160/3-60
B-10SDS 160/4-60
B-10SDS 160/5-60

P2 Rated motor power output

kW

HP

37
75
110
132
150

50
100
150
180
200

n 3450 rpm

m3/h

l/min

H
m

H Total head in m

64
128
192
256
320

96

120

150

160

168

175

180

192

DN

1600 2000 2500 2666 2800 2916 3000 3200


55
110
165
220
275

53
106
159
212
265

49
98
147
196
245

48
96
144
192
240

47
94
141
188
235

46
92
138
184
230

45
90
135
180
225

43
86
129
172
215

Tolerances according to ISO 9906, annex A

297

mm

mm

kg

kg

865
1035
1205
240 10 1375
1545

77
103
126
150
174

87
114
141
169
197

191 8

175

10SDS B-10SDS

10SDS 190 60 Hz

Submersible borehole pumps for 10 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights

300

U.S. g.p.m.

Imp. g.p.m.

400

600
400

800

1000

600

1200

800

Counter-flange for welding.

1000

10SDS 190

m
250

800
DN

235

10S
DS
190
/4

107

H
ft

200

179

600

CALPEDA

150

15
210
L

400
2

100
14
12
50 10
8
NPSH
6
m
4
2
0 0
0
m3/h 50
0 Q l/min 1000
0

l/s

200

3.93.067.N

100

200

150
2000

3000

20

40

0
300
5000

250
4000
60

80

75

38

70
%
65

Pst

60
55

3
26

3
25

Q m3/h 50

150

100

B-10SDS 190/1-60
B-10SDS 190/2-60
B-10SDS 190/3-60
B-10SDS 190/4-60

P2 Rated motor power output

250

200

Power
P2

3~

10SDS 190/1-60
10SDS 190/2-60
10SDS 190/3-60
10SDS 190/4-60

34
Pst
30
kW
26

kW

HP

37
75
110
150

50
100
150
200

72.348

300

22

n 3450 rpm

m /h

120

l/min

2000 2800 3200 3600 4000 4400

H
m

H Total head in m

62
124
185
247

55
110
164
219

168

49
99
150
199

192

46
92
138
184

216

41
83
125
166

240

39
78
116
155

264

35
69
104
149

Tolerances according to ISO 9906, annex A

298

DN

L1

mm

mm

kg

kg

865
1035
1205
240 10
1375

78
102
127
151

88
115
143
170

191 8

175

10SDS B-10SDS

10SDS 280 60 Hz

Submersible borehole pumps for 10 wells

Characteristic curves, performance n 3450 rpm, dimensions and weights


0 U.S. g.p.m.
200

500

0 Imp. g.p.m.

1000
500

1500

Counter-flange for welding.

1000

1500

600

10SDS 280

H
m

H
150

DN

235

ft

107
179

10S
DS
280
/3

400

CALPEDA

100

15
210
L

2
22
200

20
50 18

16
NPSH
14
m
12

3.93.067.N

10
0

m 3/h

0
0

Q l/min

l/s

100
2000
20

200
3000
4000
40

300
5000

60

6000

80

70

0
400
450
7000

100

120
48

65
%
60

44
Pst
40
kW
36

Pst

55
50

Q m3/h

100

3
26

3
25

200

32
400 72.1124450

300

38
3~

10SDS 280/1-60 - B-10SDS 280/1-60


10SDS 280/2-60 - B-10SDS 280/2-60
10SDS 280/3-60 - B-10SDS 280/3-60

P2 Rated motor power output

Power
P2

n 3450 rpm

m /h

180

3000 4000 4667 5000 5333 5667 6333 7000

kW

HP

l/min

45
92
132

60
125
180

55
110
165

H Total head in m

43
85
128

240

38
77
115

280

37
73
109

300

36
71
107

320

34
68
103

340

33
65
98

380

29
58
87

420

23
46
69

Tolerances according to ISO 9906, annex A

299

DN

mm

mm

kg

kg

831
1029
240 10
1199

78
103
127

88
116
143

191 8

175

10SDS B-10SDS

SD, SDS

Submersible motor pumps

Cables connection kit


It allows connection of electric cables with junction submerged in water.
The kit includes:
- 4 connectors
- 4 shrink-sheaths for protection of individual wires
- 1 shrink-sheath for protection of the 4-pole wire.
The sheath shrinks with heating (flame or drier) which causes resin outlet granting connection waterproofing.

Installation examples
12/13

16

11

14

10
7

Hd

Hd

Hs

Hs

Hs

3.93.1O8/1

Hd

3.93.108/2

1 Submersible pump
2 Pump support system
3 Electric control board
4 Circuit breaker
5 Minimum level probes
6 Pressure gauge
7 Check valve
8 Throttle gate valve
9 Pressure switch
10 Pressure tank
11 Probes for air entry control
12 Electric valve
13 Compressor
14 Membrane tank
15 Storage tank
16 Start-stop probes

Hs Static level
Hd Dynamic level
P Tubewell depth

300

3.93.108/3

15

CS

60 Hz

Submersible motors
Construction
The Calpeda 4, 6, 8 and 10" submersible motors are built
using advanced technology and components of superior quality that they ensure good mechanical strength and excellent
electrical reliability.
The 4" motors have a special food grade dielectric fluid that
gives a better lubricant effect, increasing the life of all moving
parts and the copper wires.
The 6, 8 e 10 motors are in a water bath with the wire being
coated with polyvinyl chloride.
All the Calpeda motors can be rewound and they are NEMA
STANDARD.

Operating conditions
Motor
4
6

Max. Liquid
temperature
35 C
25 C

25 C

10

25 C

Cooling
minimum flow velocity
0,08 m/s
0,20 m/s for 4 15 kW
0,50 m/s for 18,5 30 kW
0,20 m/s for 30 51 kW
0,50 m/s for 55 75 kW
0,50 m/s

Max. starts
per hour
20
15
15
10

Continuous duty.

Operation data
2-pole induction motor, 60 Hz (n = 3450 1/min).
Sized for connection to the pumps according to NEMA
Standards.
Standard voltages:
- single-phase 220 V - up to 2,2 kW for 4 motors.
- three-phase 220 V; 380 V for 4 motors.
- three-phase 380 V; 380/660 V for 6-8-10 motors.
Voltage tolerance : 5%.
Recommended type of starting for powers from 7.5 kW:
star/delta, soft start, impedance starting, autotransformer.
Insulation class F for 4 motors, PVC coated wire for 6-8-10 motors.
Protection IP 68.

Cable

kW
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
13
15
18,5
22
26
30
37
45
51
55
59
66
75
92
110
132
150

4"CS
1~
0,37
0,55
0,75
1,1
1,5
2,2

4"CS
3~
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5

6"CS
3~

4
5,5
7,5
9,2
11
13
15
18,5
22
26
30

8"CS
3~

30
37
45
51
55
59
66
75

10"CS kW
3~
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
13
15
18,5
22
26
30
37
45
51
55
59
66
75
92
110
132
150

75
92
110
132
150

4.93.325-60Hz

301

Motor 220V - 60Hz - 1~


4CS 0,37 2,2 kW

Section
4 G 2 mm2

Length
2 m

Motor 380V - 60Hz - 3 ~


4CS 0,37 2,2 kW
4CS
3 5,5 kW
6CS 4 26
kW
6CS
30
kW
8CS 30 51 kW
8CS 55 66 kW
8CS
75
kW
10CS 75 - 92
kW
10CS 110 - 132 kW
10CS 150
kW

Section
4 G 2 mm2
4 G 2 mm2
3 + 1 x 6 mm2
3 + 1 x 16 mm2
3 + 1 x 16 mm2
3 + 1 x 25 mm2
3 + 1 x 35 mm2
3 + 1 x 35 mm2
3 + 1 x 70 mm2
3 + 1 x 95 mm2

Length
2 m
3,5 m
3,5 m
3,5 m
4 m
4 m
4 m
4 m
4 m
4 m

Materiales
Components
External frame
Motor flange
Shaft
Thrust bearing
Components
External frame
Supports
Shaft
Thrust bearing
Bushings

4
Cr-Ni steel AISI 304
Brass or Cast iron
Cr-Ni-Mo steel AISI 316

Oil wetted
6, 8, 10
Cr-Ni steel AISI 304 (Fe P01 plate motor 10)
Cast iron GJL 200 EN 1561
Hardened and tempered Cr steel AISI 420
Oscillation pads
Graphite (Bronze for 8 motor of 51-59-66 kW)

Special features on request


- Other voltage.
- Special mechanical seal for 6,8,10 motors.
- Cr-Ni-Mo steel AISI 316 shaft for 6,8,10 motors.
- Operation with frequency converter.
- Higher liquid temperature.

39

4"CS - 3 ~
4CS 0,37T
4CS 0,55T
4CS 0,75T
4CS 1,1T
4CS 1,5T
4CS 2,2T
4CS 3T
4CS 4T
4CS 5,5T

HP
0,5
0,75
1
1,5
2
3
4
5,5
7,5

IN
380 V
A
1,6
1,85
2,35
3,3
4,5
6,2
7,9
10
13,3

Power factor
cos
4/4
3/4
2/4
0,64 0,57 0,48
0,75 0,66 0,57
0,75 0,65 0,53
0,76 0,67 0,55
0,74 0,65 0,53
0,71 0,62 0,47
0,75 0,68 0,56
0,76 0,68 0,55
0,79 0,71 0,59

HP
5,5
7,5
10
12,5
15
17,5
20
25
30
35
40

IN
380 V
A
12,3
14,6
19,2
23,7
28,3
30,5
34
41
52.7
67.5
72

P2

Type
kW
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5

6"CS - 3 ~
P2

Type
6CS 4
6CS 5,5
6CS 7,5
6CS 9,2
6CS 11
6CS 13
6CS 15
6CS 18,5
6CS 22
6CS 26
6CS 30

kW
4
5,5
7,5
9,2
11
13
15
18,5
22
26
30

6"FK - 3 ~
Type
6FK 37
6FK 45

P2
42,8 kW
(50HP S.F. 1,15)
51,4 kW
(60HP S.F. 1,15)

8CS 30
8CS 37
8CS 45
8CS 51
8CS 55
8CS 59
8CS 66
8CS 75

HP
40
50
60
70
75
80
90
100

10"CS - 3 ~
P2

Type
10CS 75
10CS 92
10CS 110
10CS 132
10CS 150

kW
75
92
110
132
150

3450

4/4
56
61
67
68
70
75
77
79
80

Power factor
cos
4/4
3/4
2/4
0,73 0,65 0,57
0,81 0,74 0,63
0,84 0,77 0,65
0,79 0,71 0,62
0,78 0,71 0,63
0,80 0,71 0,58
0,82 0,74 0,60
0,84 0,76 0,63
0.71 0.62 0.48
0.67 0.58 0.45
0.71 0.62 0.48

4/4
68
71
71
75
76
81
82
82
85
85
85

Efficiency
%
3/4
65
69
68
73
75
80
81
81
87
84
85

IN
380 V
A
93,2

Power factor
cos
4/4
3/4
2/4
0,85 0,81 0,73

Efficiency
%
4/4
3/4
2/4
82
83
81

110,2

0,85

84

0,72

84

3,8
4,4
4,4
4,3
4,0
4,0

0,73
0,71
0,70
0,64
0,67
0,39

R.P.M.

Efficiency
%
3/4
47
58
63
65
67
75
75
79
80

0,81

CA
CN

Axial Service I with S.F. Capacitor


thrust Factor 220V 450 Vc
A
f
N
5,1
16
1,6
25
1,5
6,6
30
1,4
8,4
1500
40
1,3
10,7
60
1,25
14
70
1,15
17,4

Direct start
2/4
39
48
56
57
62
70
70
76
77

R.P.M.

3450

IA
IN

CA
CN

5,4
4,6
5,1
5,5
5,5
6,4
6,6
7,2
7,6

6,0
3,9
3,9
4,3
4,2
4,2
3,7
2,5
4,4

Direct start
2/4
56
62
63
66
68
76
78
78
82
81
82

82

R.P.M.
3450

3500

Is
IN

Cs
CN

5,9
5,0
5,2
6,1
6,8
7,5
6,8
6,8
7,1
7,4
7,0

2,38
1,73
1,80
2,00
2,40
2,80
2,50
2,50
3,00
3,00
2,60

Direct start
R.P.M.
3500

Is
IN

Cs
CN

5,4

2,40

5,7

2,35

Axial Service I with S.F.


thrust factor 380V
A
N
1,9
1,6
1,5
2,4
1,4
2,9
1500
1,3
3,8
1,25
5,1
1,15
6,8
1,15
8,7
1,15
4500
11,3
1,15
15,1

Axial Service I with S.F.


thrust factor 380V
A
N
13,3
1,15
16,2
1,15
21,7
1,15
26,4
1,15
31,8
1,15
20000 1,15
34
37,8
1,15
46
1,15
57,4
1,15
72
1,15
78,5
1,15

Axial Service
thrust factor
N
--27500

---

Weight

mm
327
347
377
407
467
517

kg
7,7
8,7
9,9
11,3
13,6
16,7

Weight

mm

kg

327
327
347
377
407
507
473
538
638

7,7
7,7
8,7
9,7
11,3
15
15,1
18,1
22,5

Weight

mm

kg

530
530
580
630
680
780
780
830
930
1130
1130

40
40
45
50
55
65
65
70
80
100
100

Weight

mm

kg

1332

135

1484

148

Connection

4" NEMA

96

Connection

6" NEMA

145
Sporgenza

6" NEMA

137

8" NEMA

P2
kW
30
37
45
51
55
59
66
75

2/4
34
37
40
42
44
50

IA
IN

Connection

8"CS - 3 ~
Type

4/4
50
55
57
59
57
66

Direct start

38

HP
0,5
0,75
1
1,5
2
3

Efficiency
%
3/4
43
48
50
53
53
60

HP
100
125
150
180
200

P2 Rated power output

IN
380 V
A
66,5
77
97
118
125
131
151
160

Power factor
cos
4/4
3/4
2/4
0,81 0,71 0,56
0,85 0,78 0,67
0,81 0,75 0,61
0,76 0,66 0,54
0,76 0,68 0,55
0,78 0,70 0,58
0,76 0,67 0,58
0,81 0,72 0,60

4/4
85
85
87
88
88
88
87
88

Efficiency
%
3/4
84
84
86
87
87
88
85
87

Direct start
2/4
82
81
83
84
84
85
81
83

R.P.M.

3500

IS
IN

CS
CN

6,3
6,2
6,9
9,5
9,0
8,6
8,7
8,3

1,63
1,43
1,90
2,30
2,20
2,10
2,20
2,00

Axial Service I with S.F.


thrust factor 380V
A
N
1,15
72,5
1,15
89
1,15
109
1,15
132
30000
1,15
139
1,15
147
1,15
167
1,15
180

Weight

mm

kg

1056
1156
1236
1376
1376
1376
1576
1576

141
161
177
205
205
205
245
245

101,5

4CS 0,37M
4CS 0,55M
4CS 0,75M
4CS 1,1M
4CS 1,5M
4CS 2,2M

kW
0,37
0,55
0,75
1,1
1,5
2,2

Power factor
cos
4/4
3/4
2/4
0,88 0,82 0,76
0,87 0,83 0,76
0,90 0,83 0,75
0,93 0,85 0,75
0,95 0,94 0,88
0,95 0,89 0,83

IN
220 V
A
3,9
5,3
6,7
9,1
12,8
16,3

73

P2

Type

73

4"CS - 1 ~

Submersible motors

1/2" UNF

60 Hz

191
Connection

8" NEMA

IN
380 V
A
160
202
254
281
316

Power factor
cos
4/4
3/4
2/4
0,85 0,78 0,67
0,83 0,78 0,67
0,79 0,72 0,60
0,84 0,77 0,65
0,84 0,76 0,65

IN Rated current

4/4
83
83
84
85
86

Efficiency
%
3/4
82
82
83
84
85

Direct start
2/4
77
77
79
80
80

R.P.M.

3500

IS
IN

CS
CN

7,3
7,2
8,3
8,7
9,3

1,61
1,60
1,80
1,86
2,00

IA Starting current / Rated current


IN

302

Axial Service I with S.F.


thrust factor 380V
A
N
1,15
180
1,15
223
278
30000 1,15
1,15
315
1,15
355

Weight

mm

kg

1180
1280
1480
1580
1680

219
262
350
393
436

CA Starting torque/Nominal torque


CN

101,5

CS

240

CS

60 Hz

Submersible motors

Motor Cooling
To ensure a suitable cooling, water must be in touch with the motor casing with a
minimum velocity according to the following table
Motor

Water
temperature

4
6

35 C
25 C

25 C

10

25 C

Water passage velocity


Minimum
Recommended
0,08 m/s
1 m/s
1 m/s
0,20 m/s for 4 15 kW
0,50 m/s for 18,5 30 kW
0,20 m/s for 30 51 kW
1 m/s
0,50 m/s for 55 75 kW
0,50 m/s
1 m/s

For operation with higher temperatures, contact our Technical Sales Department

Cooling jacket
When the submersible motor is installed :

(fig. B)

- below the well inlet points (picture A);


- in tanks, lakes, basins, etc (pictures B and C)
an external jacket must be installed to create a
cooling flow around the motor. Only in this way
a safe operation can be assured avoiding any
overheating which can damage the motor.

4.93.324/2
CALPEDA

(fig. A)
4.93.324/2

(fig. C)

CALPEDA

CALPEDA

39

4.93.324/3

303

NC3

60 Hz

Three speeds circulating pumps


with threaded ports

Construction
Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Brass or cast iron unions on request.
Materials
Pump casing
Impeller
Shaft

NC3 ..40-50-60
Cast iron
Composite
Stainless steel

Installation

NC3 ...70-80-85-120
Cast iron
Composite
Ceramic

Applications
For clean liquids, without abrasives, which are non-aggressive for the
pump materials.
Civil and industrial heaty sistems.

Unions
Bocchettoni

Operating conditions

Rohrverschraubung

Unions
Manchons

Liquid temperature from +5 C to +110 C (from -10 C to +110 C


for NC3 ..-70-80-85-120).
Ambient temperature up to 40 C.
Sound pressure 43 dB (A).
Maximum glycol quantity: 50% (Mixture with more than 20% glycol
content require recheking of the pumping data).
Maximum permissible working pressure 10 bar.

TYPE

Uniones

0,05

0,4

1,1

NC3 ..-70

0,05

0,4

1,1

NC3 ..-80,85,120

0,05

0,4

1,2

Motor
2-pole induction motor, 60 Hz.
Three adjustable speeds.
NC3: single-phase 220 V.
Insulation class H.
Protection IP 44.

DN1

DN

DN1

(NC3 15..)

G1

G 1/2

KIT G 1 1/2 - G 1

(NC3 25..)

G 1 1/2

G1

KIT G 2 - G 1 1/4

(NC3 32..)

G2

G 1 1/4

TIPO - TYPE
TYPE - TYP

KIT G 1 - G 1/2

Minimum suction pressure: bar


Temperature
50 C
80 C
110 C

NC3 ..-40,50,60

DN

40
Designation
Series
DN ports in mm
Max. head in dm
Connection size mm
Frequency 60 Hz

305

NC3 32 - 70 / 180 - 60

NC3

Three speeds circulating pumps


with threaded ports

60 Hz

Characteristic curves, dimensions and weights


6

NC3 ...-40
60Hz

NC3 ...-50
60Hz

Hm

Hm

2
2
1

0
0

3
Q m /h
l/min 10
0

l/s

1.5
20

0.2

0.3

2.5

30
0.4

40

0.5

0.6

3.5

50

0.7

0.8

0
0.9

60

30
%
20

2
1

30
20
0 Q m3/h

1.5

0.2

0.3

2.5

30
0.4

40

0.5

0.6

3.5

50

0.7

0.8

0.9

40
3

50

l/s

1.5
20

100

40

PW
40

3
Q m /h
l/min 10

2.5

80
PW
60

10

40

20

3.5

30
%
20

10

0
0 Q m3/h

1.5

2.5

DN

3.5

B
C

NC3 ...-60
60Hz

4
3

3
2

Hm

DN

80
1

107

49

TYPE

DN
0

3
0
Q m /h
l/min 10
0

l/s

1.5
20

0.2

0.3

2.5
40

30
0.4

100

0.5

0.6

0.7

3
50
0.8

20

80

20

15
%
10

40

0 Q m3/h

NC3 15-40/130-60
G1
NC3 25-40/130-60 G 1 1/2
NC3 25-40/180-60 G 1 1/2

0.9

PW
60

3.5

5
1

1.5

2.5

3.5

306

G1
NC3 15-50/130-60
NC3 25-50/130-60 G 1 1/2
NC3 25-50/180-60 G 1 1/2
G2
NC3 32-50/180-60
G1
NC3 15-60/130-60
NC3 25-60/130-60 G 1 1/2
NC3 25-60/180-60 G 1 1/2
G2
NC3 32-60/180-60

1x
P1 230 V
Pos. (W) [A]

mm
A

C [kg]

3
2
1

53 0,23 130 128 21 2,2


47 0,21 130 135 28 2,4
38 0,17 180 135 28 2,6

3
2
1

130 128
91 0,38
130 135
65 0,28
42 0,18 180 135
180 138

21 2,2
28 2,4
28 2,6
31 3

3
2
1

130 128
95 0,41
130 135
70 0,30
44 0,20 180 135
180 138

21 2,2
28 2,4
28 2,6
31 3

NC3

60 Hz

Three speeds circulating pumps


with threaded ports

Characteristic curves, dimensions and weights


8

NC3 ...-70
60Hz

Hm

NC3 ...-80
60Hz

Hm

2
2

1
1

0
0

3
Q m /h
l/min

2
20

0 l/s

30

3
40

50

0.5

4
60

5
70

80

90

3
2
Q m /h
l/min

0 l/s

1.5

50

10

40

300

PW

200

PW

11

150

100

3
2

100

0
0 Q m3/h

3
Q m /h

10

11

DN

180

DN
80

TYPE

NC3 25-70/180-60

DN
G
1 1/2

NC3 32-70/180-60 G 2

NC3 32-80/180-60 G 2

P1
Pos. (W)

1x
230 V
[A]

[mm]
D

[kg]

3
2
1

148
128
87

0,66
0,59
0,41

135 107 49

2,9

3
2
1
3
2
1

148
128
87

0,66
0,59
0,41

138 107 49

3,1

206
185
120

0,91
0,88
0,60

185 143 58

4,7

307

40

NC3

Three speeds circulating pumps


with threaded ports

60 Hz

Characteristic curves, dimensions and weights


8

NC3 ...-120
60Hz

NC3 ...-85
60Hz

3
3

Hm

Hm
2

1
1

0
0

3
2
Q m /h
l/min

4
50

0 l/s

10
150

100
2

12

200

40

300
3

200
100

0.4

0.6

0
4

10

0.8

100

10

12

0 Q m3/h

180

DN

Pos.

G2

3
2
1

NC3 32-120/180-60 G 2

3
2
1

NC3 32-85/180-60

1.2

P1
(W)
277
250
172
265
251
176

308

1.4

1.6

1.8

2,2

TYPE

8
120

100

DN

DN
80

80

PW

20

60

200

30

0 Q m3/h 2

l/s

4
40

300

PW

3
Q m /h
l/min 20

1x
230 V
[A]

[mm]
B

1,2
1,16 185 143 58
0,85
1,15
1,14 208 174 68
0,85

[kg]
4,9

5,2

NCS3

60 Hz

Circulating pumps
for sanitary hot water

Construction

Installation

Bronze pump casing with suction and delivery connections with the
same diameter and on the same axis (in-line).
Stainless steel AISI 316 can.
Brass unions on request.

Materials
Pump casing
Impeller
Shaft
Bearings

NCS3 ..-40, -50


Bronze
Composite
Stainless steel
Graphite

NCS3 ...-70
Bronze
Composite
Ceramic
Ceramic

Unions
Applications

Bocchettoni

Circulation of sanitary hot water.

Unions

DN

Rohrverschraubung
Manchons

Operating conditions

Uniones

Liquid temperature from +5 C to +65 C.


Ambient temperature up to 40 C.
Sound pressure 43 dB (A).
Minimum suction pressure: 0,05 bar at 50 C
Maximum permissible working pressure 10 bar.

DN1

TIPO -TYPE
TYPE - TYP

KIT G 1 1/4 - G 3/4

(NCS3 20..)

Dsignation
Motor
Srie
DN des orifices en mm
Hauteur max dm
Entraxe pour installation mm
Frequency 60 Hz

2-pole induction motor, 60 Hz.


Three adjustable speeds.
NCS3: single-phase 220 V.
Insulation class H.
Protection IP 44.

309

DN

DN1

G 1 1/4

G 3/4

NCS3 2 0 - 4 0 / 1 3 0 - 6 0

40

NCS3

Circulating pumps
for sanitary hot water

60 Hz

Characteristic curves, dimensions and weights


6

NCS3 ...-40
60Hz

NCS3 ...-50
60Hz

Hm

Hm

2
2
1

0
0

3
Q m /h
l/min 10
0

l/s

1.5

20

0.2

0.3

2.5

30
0.4

40

0.5

0.6

3.5

50

0.7

0.8

0
0.9

60

30
%
20

2
1

30
20
0 Q m3/h

1.5

0.2

0.3

2.5

0.4

40

0.5

0.6

3.5

50

0.7

0.8

0.9

40

2.5

80
PW
60

10

40

20

3.5

10

0
0 Q m3/h

1.5

2.5

DN

NCS3 ...-70
60Hz

30
%
20

3.5

128
21

Hm

3
Q m /h
l/min
0

DN
80

2
20

l/s

30

3
40

50

0.5

4
60

70

107
49

TYPE

Pos.

NCS3 20-40/130-60

G 1 1/4

3
2
1

53
47
38

0,23
0,21 130
0,17

2,3

NCS3 20-50/130-60

G 1 1/4

3
2
1

91
65
42

0,38
0,28 130
0,18

2,5

NCS3 20-70/130-60

G 1 1/4

3
2
1

148
128
87

0,66
0,59 130
0,41

3,8

2
1

0 Q m3/h

310

1x
P1 230 V A
(W)
[A] mm [kg]

DN

80

PW

2
30

50

l/s

1.5
20

100

40

PW
40

3
Q m /h
l/min 10

IDROMAT 3-4 60 Hz

Electronic regulator for pumps


Construction
Regulation device for pump control equipped with flow and
pressure sensor connected to an electronic system.
Inlet and delivery connection ports of the same diameter (G1).
Built-in check valve.
Pressure gauge 0-10 bar supplied as standard for all the models.
Automatic reset function in IDROMAT4 for the reset of the
system without manual operation.

Applications
Automatic control of pumps for water supply and increase of
network pressure.
Control of starting/stopping of the pump when cocks are
opened/closed.
For protection of the pump:
against dry running;
against the risk of operation without water at the inlet (caused by a lack of water inflow in the inlet pipe under positive
suction head, by a non-immersed suction pipe, by excessive
suctionlift or by air entering the suction pipe);
against operation with closed connection ports.

Operating conditions
Switching-on
pressure

TYPE

IDROMAT 3-12
1,2 bar
IDROMAT 3-15
1,5 bar
IDROMAT 3-22
2,2 bar
IDROMAT 3-30
3,0 bar
IDROMAT 4
adjustable
(1) 1,5 bar more than the expected restart pressure

Pump
head
> 20 m
> 23 m
> 30 m
> 40 m
(1)

Materials
Component

IDROMAT 3-4

Housing

Polyamide PA 6 G.F. reinforced

Membrane

Natural rubber

For pumps with delivery up to 10 m3/h.


Maximum working pressure: 10 bar.
Liquid temperature up to 60 C.
Mains voltage: 230 V 10%, single-phase.
Frequency: 50 - 60 Hz.
Protection: IP 65.
Current values:
- 8A max during operation (16A max at start-up) for IDROMAT 3;
- 16A max during operation (30A max at start-up) for IDROMAT 4

Comparison of pressure values

Diagram of head loss


30

H
H
m

Pump outlet head

B
20

10

41

Time
4.93.054

0
A = operation with IDROMAT = constant pressure;
B = operation with traditional vessel and pressure switch system.

0 Q m3/h

H = Head loss in meters

311

10

12

IDROMAT 3-4 60 Hz

Electronic regulator for pumps

Dimensions and weights


Weights
IDROMAT 3 kg 1,17
IDROMAT 4 kg 1,35
150
62,5

220

62,5

65

155

IDROMAT 3
On

Reset

220-240 V
50-60 Hz
16 (8) A max.
10 bar max.
IP 65

155

102

ELECTRONIC PUMPS REGULATOR

Power
Failure

Made in EU

R1

125

IDROMAT 3-12:
IDROMAT 3-15:
IDROMAT 3-22:
IDROMAT 3-30:

IDROMAT 3-12:
IDROMAT 3-15:
IDROMAT 3-22:
IDROMAT 3-30:

Check valve

max 12 m
max 15 m
max 22 m
max 30 m

max 12 m
max 15 m
max 22 m
max 30 m

Installation example

4.93.096
4.93.096

Foot valve

312

Pressure Boosting Sets


Fixed speed pump units
Variable speed pump units with frequency converter

42

313

Pressure Boosting Sets


MINIMAT, TURBOMAT
CENTRIMAT, GETTOMAT

70
NMD

Small automatic water systems with 1 pump


series MXH, MXP, NM, NG, NGX

60

50

T,TP

H
m

NG
NGX

MXH
MXP

NM

30

20

VARIOMAT
Constant pressure boosting sets with Variomat frequency converter
with 1 MXH, MXSU, MXVB

0 Q m3/h 2

70
H
m
50

10

10

MXH

40
30
2

20

20
PWM 230

70
H
m
50

MXSU

40
30

MODE

0 Q m3/h 4

16

10
6

10

SET

0 Q m 3/h 10

20

28

Made in Italy

MXV-B

100

4.93.335.1

4.93.336.1

H
m
50
40

25-2..

30
20

VARIOMAT
Constant pressure boosting sets with Variomat frequency converter
with 2 MXH, MXSU, MXVB

1 Q m3/h 2

70
H
m
50

10
PWM 230

MODE

MODE

SET

4 5

10

20

MXH

40
30
2

20

4
0 Q m3/h 8

16

10

12

16

20

0 Q m 3/h 20

PWM 230

MODE

MODE

SET

Made in Italy

40

36

SET

MXV-B

Made in Italy

100
PWM 230

30

70
H
m
50

MXSU

20

PWM 230

40
30

Made in Italy

32-4.. 40-8.. 50-18..

H
m
50
40

SET

Made in Italy

PWM 230

PWM 230

MODE

MODE

SET

Made in Italy

SET

Made in Italy

25-2..

32-4.. 40-8.. 50-18..

30
4.93.334.2

20
4.93.335.2

BS2F

BS1V1F, BS2V

90

Fixed speed pump pressure boosting


sets for domestic use
with 2 MXH, MXP, NM, NG, NGX

Variable speed pump pressure boosting


sets for domestic use
with 2 MXH, MXP, NM, NG, NGX

80

2 Q m3/h

10

20

40

60

NMD

70
60
NM

50
H
m

NG
NGX

30
20

314

0 Q m3/h

MXH
MXP

12

16

20

24

28

Pressure Boosting Sets


BS2F

BS1V1F, BS2V

70

Fixed speed pump Pressure boosting


sets for domestic use with 2 MXSU

Variable speed pump pressure boosting


sets for domestic use with 2 MXSU

60

2MXSU

50
H
m
30

2MXSU 2
2MXSU 4

20

2MXSU 8

10
0

BS3F

BS1V2F, BS3V

70

Fixed speed pump Pressure boosting


sets for domestic use with 3 MXSU

Variable speed pump pressure boosting


sets for domestic use with 3 MXSU

60

Q m3/h

12

16

20

24

3MXSU

50
H
m
30
3MXSU 2

20

3MXSU 8

3MXSU 4

10
0

BS2F

BS1V1F, BS2V

0 Q m 3/h

12

18

24

30

36

100

Fixed speed pump pressure boosting Variable speed pump pressure boosting
sets for civil use with 2 MXVB, MXV sets for civil use with 2 MXVB, MXV

2MXV
80
H
m
60

40

20
0

25-2

2 Q m 3/h 4

32-4

8 10

40-8

16 20

50-16 65-32 80-48

32 40

64

100 140

100

BS1V1F, BS2V
Variable speed pump (on-board frequency converter) pressure boosting
sets for civil use with 2 MXVE

2MXVE
80
H
m
60

42

40

20
0

315

25-2

2 Q m 3/h 4

32-4

8 10

40-8

16 20

50-16 65-32 80-48

32 40

64

100 140

Pressure Boosting Sets


BS3F

BS1V2F, BS3V

Fixed speed pump pressure boosting Variable speed pump pressure boosting
sets for civil use with 3 MXVB, MXV sets for civil use with 3 MXVB, MXV

100
3MXV
80
H
m
60

40

0
2 Q m3/h 5

BS1V2F, BS3V

32-4 40-8

25-2

20

10

50-16

65-32 80-48

20 30 40 50

100

200

100

Variable speed pump (on-board frequency converter) pressure boosting


sets for civil use with 3 MXVE

3MXVE
80
H
m
60

40

0
2 Q m3/h 5

BS2F

BS1V1F, BS2V

32-4 40-8

25-2

20

10

50-16

65-32 80-48

20 30 40 50

100

200

130

Fixed speed pump pressure boosting Variable speed pump pressure boosting
sets for civil use with 2 NM, NMD
sets for civil use with 2 NM, NMD

2NM
100
32/210

H
m

40/25

50/25

40/20

50/20

65/250

80/250

50
40
30

32/20

32/16

40/16

50M 65/200

50/16
65/16

20

BS3F

20 Q m3/h 40

80/200

60

80 100

80/16

400

200

120

BS1V2F, BS3V

Fixed speed pump pressure boosting Variable speed pump pressure boosting
sets for civil use with 3 NM
sets for civil use with 3 NM

3NM

100
H
m

40/25

50/25

80/25

65/25

50
40/20

40

50/20

50M

65/20

80/20

30
40/16

20

3.93.115

316

50

Q m3/h 100

65/16

50/16

200

80/16

300 400

600

Pressure Boosting Sets


Designation
CENTRIMAT 1/1 MXH 205E /20
CENTRIMAT MXH 205E /24
Tank capacity (litres)
Pump type
With tank under the pump
(no indication: tank above the pump)
Product series

2 MXH 204 - V MT
2 MXH 204 - V TT
MT Sigle-phase supply
TT Three-phase supply
VARIOMAT series
Pump type
Nr of pumps

BS M 2V
2 MXV 25/204
BS M 1V 1F 2 MXV 25/204
BS M
2F 2 MXV 25/204
Pump type
Nr of pumps
2F
3F
1V1F
1V2F
2V
3V

2 fixed speed pumps


3 fixed speed pumps
1 variable speed pump and 1 fixed speed pump
1 variable speed pump and 2 fixed speed pumps
2 variable speed pumps
3 variable speed pumps
Sigle-phase supply
(no indication: three-phase supply)
Product series

317

42

Operation
MINIMAT

VARIOMAT

BSF

with 1 fixed speed pump

with 1 variable speed pump

with fixed speed pumps

Construction

Construction

Construction

Small pressure boosting sets with automatic operation, consisting


of pump, pressure switch and 1 litre diaphragm tank.

Pressure boosting sets


with automatic operation
and constant pressure,
consisting of a variable
speed pump driven by
Variomat frequency converter, with gate and nonreturn valves, pressure
gauge, 8 litres diaphragm
tank.

Pressure boosting sets with automatic operation, consisting in 2 and 3 pumps on a common baseplate, with sunction and delivery
manifolds, gate and non-return valves, pressure switches, pressure gauge, control panel
and from 100 to 1000 litres diaphragm tank.

1l

Operation
Pump is directly driven by the pressure switch.
MINIMAT
MINIMAT
1 pompa
fixed speed
pump
1
a velocit
fissa

H
m

Var.

BS 2F
BS 2F

pompe
a velocit fissa
2 fixed2speed
pumps

Operation

Variable speed pump is directly driven by


Variomat frequency
converter.
VARIOMAT
VARIOMAT
variable
speed variabile
pump
11pompa
a velocit

H
m

BS 3F
BS 3F

pompe
a velocit fissa
3 fixed3speed
pumps

Stop

H set
F

Start

Q m 3/h

TURBOMAT, CENTRIMAT,
GETTOMAT

VARIOMAT
with 2 variable speed pumps

Construction

Small pressure boosting sets with automatic


operation, consisting of with pump, pressure
switch, pressure gauge and diaphragm tank
(24litres if above the pump, 20litres if under
the pump).

Q m 3/h

with 1 fixed speed pump

Construction

Pressure boosting sets with automatic operation and constant pressure, made up with 2
variable speed pumps on a common baseplate driven by Variomat frequency converter,
with suction and delivery manifolds, gate and
non-return valves, pressure gauge, 8 litres
diaphragm tank and control panel with two
magnetothermal switches.

24 l

Var.

Var.

Operation
The control panel, with electronic card, manages the pump operation, the changeover of
pump starting sequence and it stops the
system when there is no air in the tank (patented system).
Pumps starting in a cascade sequence, with a
signal from the pressure switches.

BS 2F
BS 2F

2 fixed
speed pumps
2 pompe
a velocit fissa

H
m

Stop

Operation

Start

Pump is directly driven by the pressure


switch..

Operation
Pumps starting in a cascade sequence, with
changeover of pump starting sequence.

TURBOMAT, CENTRIMAT,
MINIMAT GETTOMAT

BS 3F
BS 3F

VARIOMAT
VARIOMAT

fixed speed
pump
1 1pompa
a velocit
fissa

H
m

Q m 3/h
3 pompe
a velocit fissa
3 fixed
speed pumps

2 1variable
pumps
pompaspeed
a velocit
variabile
H
m

H
m

Stop

Stop

H set

Start

Start

Q m 3/h

Q m 3/h

318

Q m 3/h

BSV.F.

BSV

BSV.F.

BSV

with variable and fixed speed


pumps (frequency converter
into the control panel)

with variable speed pumps


(frequency converter into the
control panel)

with variable speed pumps


(on board frequency converter)

with variable speed pumps


(on board frequency converter)

Construction

Construction

Construction

Construction

Pressure boosting sets with automatic operation, consisting of 1 variable


speed pump with frequency converter into the control panel and from 1
to 5 fixed speed pumps, assembled
on a common baseplate, with suction and delivery manifolds, gate and
non-return valves, pressure gauge,
control panel and 20 litres diaphragm tank.
1V1F
BS 1V1F

Pressure boosting sets with automatic operation, consisting of


variable speed pumps (from 1 to 6)
with frequency converter on the
control panel, assembled on a
common baseplate, with suction
and delivery manifolds, gate and
non-return valves, pressure transducer, pressure gauge, control
panel and 20litres diaphragm
tank.ri. BS
BS 2V
2V

Pressure boosting sets with automatic operation, consisting of 1 variable


speed pump with frequency converter into the control panel and from 1
to 5 fixed speed pumps, assembled
on a common baseplate, with suction and delivery manifolds, gate and
non-return valves, pressure gauge,
control panel and 20 litres diaphragm tank.

Pressure boosting sets with automatic operation, consisting of variable


speed pumps (from 1 to 6) with frequency converter on the control
panel, assembled on a common
baseplate, with suction and delivery
manifolds, gate and non-return valves, pressure transducer, pressure
gauge, control panel and 20litres
diaphragm tank.

BS1V1F
1V1F
BS

pompe aspeed
velocit
variabile
22 variable
pumps

pompe: 1variable
1 variabile
2 pumps:
1 fixed
fissa

BS 2V
2V
BS

pompe aspeed
velocit
variabile
22 variable
pumps

pompe:1variable
1 variabile
22pumps:
fissa
11fixed

INVERTER

BS
BS 1V2F
1V2F

BS
BS 3V
3V

BS
BS1V2F
1V2F

33 variable
pumps
pompe aspeed
velocit
variabile

3
1variable
2 pumps:
pompe: 1
variabile
2 fixed
2
fisse

Operation
The control panel, with electronic card,
manages the pump operation, the changeover of fixed speed pumps starting sequence
Pumps starting is in a cascade sequence,
with a signal from the pressure transducer.
Constant pressure is guaranteed by the
variable speed pumps, while fixed speed
pumps start when the request is higher than
the capacity of BS
the variable
1V1F speed pump.

The control panel, with electronic


card, manages the pump operation, the changeover of pumps
starting sequence.
Pumps starting in a cascade
sequence, with a signal from the
pressure transducer.
BS 2V

1V1F
2BS
pumps:
1variable
2 pompe:
1 variabile
1 fixed
1 fissa

2V speed pumps
2BS
variable

2 pompe a velocit variabile

H
m

H set

H set

H set

H set

Q m 3/h

BS 3V

1V2F
3BS
pumps:
1variable
3 pompe: 1 variabile
2 fixed
2 fisse

Q m 3/h

BS 1V2F

3V speed pumps
3BS
variable
3 pompe a velocit variabile

BS 3V

1V2F
3BS
pumps:
1variable
3 pompe: 1 variabile
2 fixed
2 fisse

3V speed pumps
3BS
variable
3 pompe a velocit variabile

H
m

H
m

H
m

H
m

H set

H set

H set

H set

Q m 3/h

2V speed pumps
2BS
variable

H
m

Q m 3/h

INVERTER

BS 2V

1V1F
2BS
pumps:
1variable
2 pompe:
1 variabile
1 fixed
1 fissa

H
m

Q m 3/h

INVERTER

The control panel, with electronic


card, manages the pump operation, the changeover of pumps
starting sequence.
Pumps starting in a cascade
sequence, with a signal from the
pressure transducer.

H
m

BS 1V2F

INVERTER

Operation

The control panel, with electronic card,


manages the pump operation, the changeover of fixed speed pumps starting sequence
Pumps starting is in a cascade sequence,
with a signal from the pressure transducer.
Constant pressure is guaranteed by the
variable speed pumps, while fixed speed
pumps start when the request is higher
than the capacity of the variable speed
pump.
BS 1V1F

2 pompe a velocit variabile

33 variable
pumps
pompe aspeed
velocit
variabile

Operation

Operation

INVERTER

BS
BS 3V
3V

33pumps:
1variable
pompe:
1 variabile
2 fixed
2 fisse

INVERTER

INVERTER

Q m 3/h

Q m 3/h

319

42

Q m 3/h

Pressure Boosting Sets


Fixed speed pump units

Variable speed pump units with frequency


converter

New electrical control panels

New electrical control panels

for fixed speed pump units.

for variable speed pump units.

New electrical control panels


for pressurisation units, all with
electronic
card
with
microprocessors,
for
managing pump operation.

New electrical control panels


for pressurisation units with
variable speed pumps.
These are indispensible in all
those cases where constant
pressure is required and when
high pressure pumps are being
controlled.
All the various working phases
are managed and controlled by
the MPS 6000 (Multi Pumps
System) electronic card with
microprocessor, which can
operate up to 6 pumps
working simultaneously.

The microprocessor carries


out continuous secure checks
during all the various work
phases of the pumps and
incorporates all necessary
functions,
thus
reducing
electrical
and
electronic
components inside the panel.
In particular:
- pumps starting in a cascade sequence according to water demand.
- changeover of pump starting sequence.
- pumps stop when there is no water in the suction.
- delay start-up of the 2nd/3rd pump in case of breakdown of pressure
switch 1 or after a power cut.
- avoid pump starting in case of water hammering.
- activate the alarm when pressure 1 fails.
- activate the alarm when air cushion in the vessel drops.
- stop the pump when air cushion is over*.
* Patent pending

Maximum clarity of signals


All the various calibration parameters appear as messages on the
display of the MPS 6000 electronic card.
If there are any faults or defects a message appears on the display
giving details of the problem.

Possibility of remote control


The pump status can be displayed and the unit can be controlled by
means of a special computer program.
It is possible to obtain a remote warning light and acoustic signal on the
RA 100 panel.

Maximum clarity for all signals


The status of the unit can easily be identified on the front of the electronic
card with the following signals:
- Power on led.
- No water led.
- Failure led.
- Pump running led (1 for each pump).
- Thermal block led (1 for each pump).
- Pump automatic operation led (1 for each pump).
- Pump stop led (1 for each pump).

Constant or increased pressure


All the pumps can work with the same pressure value (set point), or, for
systems with high head losses, the pressure can be increased depending on the number of pumps operating.

Silent operation
Motors working at reduced speed and check valves that close gradually mean that operation is particularly quite.

Maximum simplicity of control


The front of electronic card features the following signals and controls:
- AUT-STOP push-button (1 for each pump)
- MAN push-button (1 for each pump)
- RESET push-button.

Long life for pumps


All the mechanical components of the pumps and motors are stressed
to a minimum, due to the variable speed operation.

Optional remote control

Energy savings

The new panels have been designed to remotely reproduce all the
electronic card signals (excluding the buttons), using RC 100 - RC 200 RC 300 panels, connected with a simple two-pole cable.
The RA 100 panel enables a remote warning light and acoustic signal.

The motors consume only the precise level of power necessary moment
to moment, in order to supply the quantity of water required by the
system.

Control panel for units up to 6 pumps

No more high capacity vessels

Using the MPS 6000 (Multi Pumps System) electronic card it is possible
to control pressure units up to a maximum of 6 fixed speed pumps with a
single pressure calibration.

Automatic air supply systems

The use of inverters means that high capacity pressure vessels and
membrane vessels are no longer necessary. Even units with high
flowrate pumps only require a small number of 20 litre membrane
vessels.

The pump control panels are completed by microprocessor controlled


systems for automatic air supply in the pressure vessels by means of a
compressor or solenoid valve.

Great versatility
The great versatility of the MPS 6000 electronic card enables the construction of special units with operational logics different from those of
normal pressurisation units, depending on the requirements and characteristics of the systems.

Operation

For booster sets made up to three pumps:


- according to the pressure decrease in the system, the pressure
switches make the pumps to start in cascade mode and the starting
changeover is made by the microprocessor.
For sets made of 4, 5, 6 pumps:
- Operation controlled by a microprocessor with signal from a pressure
transducer. The pumps operate with only one pressure setting.

Operation
Depending on water consumption, one or more pumps are activated, all at
variable speed, in order to guarantee the quantity of water required at
the set pressure.

320

AUE, AUD, AUED


UNI-EN 12845 fire-fighting systems

43

321

INDEX
AUE 11
UNI-EN 12845 units with 1 N series electric main pump

pag. 444

AUE 21
UNI-EN 12845 units with 2 N series electric main pumps

AUD 11
UNI-EN 12845 units with 1 N series main pump (diesel motor)

pag. 449

AUED 21
UNI-EN 12845 units with 2 N series main pumps
(electric and diesel motors)

L2

L1

START

L3

STOP

L2

L1

START

L3

AUE 11

STOP

UNI-EN 12845 units with 1 MXV series multi-stage vertical electric


main pump

pag. 454

AUE 21
UNI-EN 12845 units with 2 MXV series multi-stage vertical electric
main pumps

3.93.1028

CALPEDA

CALPEDA

AUE 11
UNI-EN 12845 units with 1 SD series submersible borehole
electric main pump

CALPEDA

pag. 458
L2

L1

L3

START

AUE 21

STOP

UNI-EN 12845 units with 2 SD series submersible borehole


electric main pumps

CALPEDA

AUE 11

CALPEDA

UNI-EN 12845 units with 1 SDS series submersible borehole


electric main pump

CALPEDA

pag. 463
L2

L1

START

L3

STOP

AUE 21
UNI-EN 12845 units with 2 SDS series submersible borehole
electric main pumps

322

AUM
Units for feeding fire-extinguishing systems
with accessories according to EN 12845
With 1 close coupled electric pump
10

30

20
20

10

40

U.S. g.p.m. 100

50

30

40

200

Imp. g.p.m. 100

50

300
200

400 500

1000

400 500

300

1000

130

400

AUM 11
100
300

...11 D32/210

AUM 11 D25/190

...11
40/25

...11 65/250

...11 50/25

...11 D40/180

50
...11 40/20

AUM 11 32/20

40

...11
50M

...11 50/20

...11
100/250

...11 80/250

200
H
ft

...11 65/200 ...11


80/200
...11 100/200

100
90

30
AUM 11 32/16

...11 40/16

...11 50/16

80

...11 65/16

...11 80/16

70

20

60
15

3
40

50

100

8 9 10
150

m 3/h

Q l/min

20
300

30

40

50

400 500

2000

1000

50
300

200

100

3000

4000 5000
72.860.2/2

With 2 close coupled electric pumps


20

60

40
40

20

80

U.S. g.p.m. 200

100

60

400

100 Imp. g.p.m. 200

80

600
400

800 1000
600

2000

800 1000

2000

130

400

AUM 21
100
300

AUM 21 D25/190

...21 D32/210

...21
40/25
...21 50/25

...21 D40/180

50
...21 40/20

AUM 21 32/20

40

...21 50/20

...21 65/250

...21
50M

...21
100/250

...21 80/250

200
H
ft

...21 65/200 ...21


80/200
...21 100/200

100
90

30
AUM 21 32/16

...21 40/16

...21 50/16

80

...21 65/16

...21 80/16

70

20

60
15

6
80

100

20

10
200

300

m 3/h

Q l/min

40
600

60
800 1000

80

100

200
2000

4000

400
6000

50
600

8000 10000
72.860.3/2

323

43

AUE
EN 12845 units for feeding fire-extinguishing systems
With 1 electric pump
30
20

40

U.S. g.p.m.

50

30

40

50

100

Imp. g.p.m.

200
100

300
200

500

400

400

300

1000
500

1000

130

400

AUE 11
100
300

AUE 11 40/250

...11 65/250

...11 50/250

50
...11 40/200

AUE 11 32/200

40

200
H

...11
50M

...11 50/200

...11
100/250

...11 80/250

ft

...11
80/200

...11 65/200

...11 100/200
100
90

30
AUE 11 32/160

...11 40/160

...11 50/160

80

...11 65/160

...11 80/160

70

20

60
15

100

9 10
150

20

m 3/h
l/min

30

300

400

40

50

500

2000

1000

50
300

200

100

3000

4000

5000

72.860.3/2

With 2 electric pumps


60
40

80

U.S. g.p.m.

100

60

80

100

200

Imp. g.p.m.

400
200

600
400

800
600

1000
800

2000
1000

2000

130

400

AUE 21
100
300

AUE 21 40/250

...21 65/250

...21 50/250

50
...21 40/200

AUE 21 32/200

40

...21 50/200

...21
50M -....

...21
100/250

...21 80/250

200
H

...21 65/200

ft

...21
80/200
...21
100/200

100
90

30
AUE 21 32/160

...21 40/160

...21 50/160

80

...21
80/160

...21 65/160

70

20

60
15

20

10
200

300

40

m 3/h
l/min

600

60
800

80

1000

100

400

200
2000

4000

6000

50
600
8000 10000
72.860.4/2

324

AUD - AUED
EN 12845 units for feeding fire-extinguishing systems
With 1 diesel pump
30
20

40

U.S. g.p.m.

50

30

40

50

100

Imp. g.p.m.

200
100

300
200

500

400

1000

400

300

500

1000

130

400

AUD 11
100
300

AUD 11 40/250

...11 80/250

...11 65/250

...11 100/250

...11 50/250

200

50
...11 40/200

AUD 11 32/200

40

...11
50M

...11 50/200

...11
80/200

...11 65/200

ft
...11 100/200
100
90

30
AUD 11 32/160

...11 40/160

...11 50/160

80

...11 65/160

...11 80/160

70

20

60
15

100

9 10
150

20

m 3/h

30

300

l/min

400

40

50

500

2000

1000

50
300

200

100

3000

4000

5000

72.860.3/2

With 2 pumps (electric and diesel)


60
40

80

U.S. g.p.m.

100

60

80

100

200

Imp. g.p.m.

400
200

600
400

800
600

1000
800

2000
1000

2000

130

400

AUED 21
100
300

AUED 21 40/250

...21 65/250

...21 50/250

...21 40/200

AUED 21 32/200

...21 100/250
200

50
40

...21 80/250

...21 50/200

...21
50M

H
...21 65/200

ft

...21
80/200
...21 100/200

100
90

30
AUED 21 32/160

...21 40/160

...21 50/160
...21 65/160

80

...21 80/160

70

20

60
15

20

10
200

300

40

m 3/h
l/min

600

60
800

80

1000

100

200
2000

400
4000

6000

50
600
8000 10000
72.860.4/2

325

43

AUE
EN 12845 units for feeding fire-extinguishing systems
With 1 electric vertical multi-stage pump MXV
U.S. g.p.m.

10

10

20

30

40

20

Imp. g.p.m.

30

50
40

100

200
100

50

300
200

120

100
300

H
m
80

AUE 11
MXV50-16

AUE 11
MXV40-8

AUE 11
MXV32-4

AUE 11
MXV65-32

ft
200

60

AUE 11
MXV80-48
40
100
20

0
2

m 3/h
l/min

50

100

9 10
150

16
200

20
300

32
400

40

48

500

60

70

1000
72.1066

With 2 electric vertical multi-stage pumps MXV


U.S. g.p.m.

20

40

60

Imp. g.p.m.

20

80

40

60

100
80

200

400
200

100

600
400

120

100
300

H
m
80

AUE 21
MXV50-16

AUE 21
MXV40-8

AUE 21
MXV32-4

AUE 21
MXV65-32

ft
200

60

AUE 21
MXV80-48
40
100
20

m 3/h

Q l/min

6
100

10

12
200

14

16 18 20
300

36
400

40
600

64
800

1000

80

96

120

0
140

2000
72.1067

326

AUE
EN 12845 units for feeding fire-extinguishing systems
With 1 electric submersible pump SD
U.S. g.p.m.

10

20

30

Imp. g.p.m.

10

20

40

50

30

100

40

50

200

300

100

200

AUE 11 4SD 15

120

400

AUE 11
100

AUE 11
6SDN 12

... 11 6SDN 21

300

AUE 11
6SDN 16

m
80

H
ft

... 11
6SD 18

AUE 11 4SD 15
60

200

... 11
6SD
20
40

... 11
6SD
19

100

20

0
2

m 3/h
l/min

50

100

9 10
150

20
200

300

30
400

40

50

60

500

70

1000
72.1068

With 2 electric submersible pumps SD


U.S. g.p.m.

20

40

60

Imp. g.p.m.

20

40

80

100

60

80

200
100

400
200

600
400
400

120

AUE 21

AUE 21 4SD 15

100

AUE 21
6SDN 12

... 21 6SDN 21

300

AUE 21
6SDN 16

80

H
ft

... 21
6SD 18

AUE 21 4SD 15
60

200

... 21
6SD
20
... 21
6SD
19

40

100

43

20

0
4

m 3/h
l/min

6
100

10

12
200

14

16

18 20
300

40
400

600

60
800

1000

80

100

120

140

2000
72.1069

327

AUE
EN 12845 units for feeding fire-extinguishing systems
With 1 electric submersible pump SDS
50
40

U.S. g.p.m.

100
50

200

300

Imp. g.p.m.

100

200

400
300

500
400

1000
500

1500
1000
400

120

AUE 11
100
300

H
m

...11
6SDS
42

AUE 11 6SDS 32

80

...11
6SDS 58

ft

...11 8SDS 100


60

...11
10
...11
SDS
8SDS 150 160

...11
10SDS
190

...11
10SDS
280

200

...11
8SDS
70

40

100
20

0
10

200

20
m3/h
l/min 300

30
500

400

40

50

100
1000

200
2000

3000

4000

300
5000

400
6000
72.1070

With 2 electric submersible pumps SDS


100
80

U.S. g.p.m.

200
100

200

400

Imp. g.p.m.

600
400

800
600

1000
800

2000
1000

3000
2000
400

120

AUE 21
100
300

H
m

...21
6SDS
42

AUE 21 6SDS 32

80

...21
6SDS 58

ft

...21 8SDS 100


60

...21
10
...21
SDS
8SDS 150 160

...21
10SDS
190

...21
10SDS
280

200

...21
8SDS
70

40

100
20

0
20

400

40
m3/h
l/min 600

800

60
1000

80

100

200
2000

400
4000

6000

8000

600
800
10000 12000
72.1071

328

ACCESSORIES
PRESSURE GAUGES

VALVES
check valve

axial connection type

VNR 1
VNR 1 1/4
VNR 1 1/2
VNR 2

MA 0-6
MA 0-6 ABS

foot valve

MR 0-10
MR 0-12
MR 0-16

radial connection type

VDF 1
VDF 1 1/4
VDF 1 1/2
VDF 2

PRESSURE SWITCHES

CONNECTOR
type

type

connection

RA5 H 92
RA5 H 105

FSG 2
FYG 22
FYG 32

G1
G1

max
standard
pressure
setting
1,4 - 2,8 bar 4,5 bar
5,4 - 7 bar
7 bar
8 - 10,5 bar 10,5 bar

CYLINDRICAL VESSEL

SPHERICAL VESSEL
type
SS 24

vessel with base and feet

connect. capacity
G1

type

24 l

SC 20 BP

connect. capacity
G1

20 l

BUTYL rubber diaphragm.


BUTYL rubber diaphragm.

INOX CYLINDRICAL VESSEL

INOX CYLINDRICAL VESSEL


vertical cylindrical vessel

vessel with base and feet

type

type

SCX 20

connect. capacity
G1

20 l

SCX 20 BP

BUTYL rubber diaphragm.

connect.
G1

capacity
20 l

BUTYL rubber diaphragm.

44
329

ACCESSORIES
KIT 1

Type

KIT 2

KIT 1A

KIT 1B

KIT 1CX

KIT 1DX

Type

Components
Connector

KIT 2A

KIT 2B

KIT 2CX

KIT 2DX

RA5 H 92

RA5 H 92

RA5 H 92

RA5 H 92

FSG 2

FYG 22

FSG 2

FYG 22

MR 0-10

MA 0-6 ABS

MR 0-10

FP 1-680

FP 1-680

FP 1-680

FP 1-680

Bend

1" M.F.

1" M.F.

1" M.F.

1" M.F.

Bend

1" F.F.

1" F.F.

1" F.F.

1" F.F.

SC 20 BP

SC 20 BP

SCX 20 BP

SCX 20 BP

Components
RA5 H 92

RA5 H 92

RA5 H 92

RA5 H 92

FSG 2

FYG 22

FSG 2

FYG 22

Pressure switch

MR 0-10

MA 0-6 ABS

MR 0-10

Pressure gauge MA 0-6 ABS

SS 24

SCX 20

SCX 20

Flexible hose

Pressure switch

Pressure gauge MA 0-6 ABS


Vessel

SS 24

Connector

Vessel

AUTOMATIC AIR FEEDER

LEVEL PROBES
ARIAMAT

type

type
SL 2 electrodes
SLA Assembled level probes
Cable 2x0,75 mm 2
(cable length on request)

AR 300E
AR 1000E
AR 2000E
Ccomplete with connections and
1 m polyethylene pipe

example:

SLA 30

Assembled level probes


30 m cable length

FLOAT SWITCH

FLEXIBLE HOSE
tipo

type

INTGALL
(cable 2,5 m)

FP 1-630
FP 1-680

Kit of level probes


with solenoid valve

Kit of level probes


with compressor

d x length
G 1 X 630
G 1 X 680

SYSTEM FOR AIR INTAKE

330

Technical appendix
How to select a centrifugal pump
The selection of a centrifugal pump should be made according to the actual
characteristics and conditions of the plant.
The required data for a correct selection are the following:

60

0 U.S. g.p.m. 50

100

150

200

A 200

50

NM 50/20

B 188

160

Hm

Total manometric head Hmt


It is considered as the sum between the geometric head exsisting between
the fluid levels and the head loss due to frictions from the fluid passage in
the pipework, into the pump and relevant hydraulic accessories.
The expression is the following:

180

50

55

60 62

H ft

Flow Q
Quantity of fluid delivered by the pump in the unit of time, generally expressed
in m3/h.

250

64 65

40

140
66%
65 64 120

Hmt = Hg + pc mt fluid column

0 Q m3/h
0 l/min
0

Hg = geometric head inlet (Hga) + geometric head outlet (Hgp)


pc = sum of head loss of the plant calculated from the following data:

l/s 2

10
200

20

30
400

40
600

10

12

P kW

12

14

100
60
1000
16

A 15

10

- Diameter, length and material of the suction and delivery piping (see table
no. 1 page 336).
- Number and type of elbows in the piping and hydraulic accessories such as
foot valves, gate valves, non-return valves and strainers etc. (see table no. 2
page 336).
- Type, temperature, viscosity and density of the fluid (if different from that of
water)

50
800

10

6
4

P HP

30

20
15

10
2

NPSH ft

NPSH m

5
Pay attention to the manometric suction lift Hga + pc asp, which should be
0
0
compared with the suction capability of the pump.
72.020
0 Q m3/h 10
20
30
40
50
60
This suction capability or NPSHr is defined as net positve suction head and its
value is obtained from a curve in accordance with the flow.
For this purpose, once the pump has been selected according to the required flow and head, where possible at the middle of the curve, check the
following simplified formula:

10 mt Hga - pc asp. > NPSH required + 0.5 mt


Hga is the difference in height between the free surface of the water, and its value is negative if the pump is installed above the free water surface.
pc asp is the sum of the remaining distributed (piping) and concentrate (valves, bends, etc.) suction head loss
If the final result is negative, it is often possible to adjust flow via a gate valve on the delivery side, in order to restore correct pump operating conditions, without cavitation.
For fluid temperatures higher than the average of about 20C, the pumps loose their suction capability.
Such changes, referred to pumps with suction capability of 7 meter at normal temperature, are shown on table no. 3 page 337.

CHARACTERISTIC DATA OF THE PUMPS


Once the flow (Q) and total manometric head of the installation (Hmt) are established, the pump absorbed power N should be calculated through the
following formula:

where:

N = Q x H x in kW
367 x p

Q = Flow in m3/h
H = Head in mt
= Fluid density (water = 1 kg/dm3)
p = Pump efficiency (Ex. Pump efficiency 68% = p = 0.68)
The pumps are normally connected to electric motors, which operate at 2900 rpm with 2-pole motors at 50Hz, or at 1450 rpm with 4-pole motors at 50Hz.
However, they can run at any other speed within the limits of design.
Therefore, when changing the number of revolutions, the pump performance will change according to the following rules:
The flow in proportion to the number of revolutions: Q2 = Q1 x

n2
n1

The head, in proportion to the square of the number of revolutions: H2 = H1 x

n2
n1

The absorbed power, in proportion to the cube of the number of revolutions: N2 = N1 x

331

( nn21 )

45

How to select a centrifugal pump


Calculation example for the selection of a centrifugal pump
Case A

Istallation data

A) Operation with suction lift


- Q (Flow) = 42 m3/h
- Hga (geometric head inlet) = 3,5 m
- Hgp (geometric head outlet) = 39 m
- 5 m DN 100 mm diameter suction pipe complete with 1 elbow
and 1 foot valve
- 70 m DN 80 mm diameter delivery pipe with 1 non-return valve, 1
gate valve and 3 sweep elbows
Hg = Hgp + Hga = 39 + 3,5 = 42,5 m Geometric head of the installation

Hgp

pc = total head loss

80 Pipe
70 m Length

Hg

Suction side:
5 m 100 piping
1 Elbows
1 Foot valve

pc = 0,12 m
pc = 0,045 m
pc = 0,46 m

Delivery side:
70 m 80 pipe
1 Non-return valve
1 Gate valve
3 Elbows

pc = 5,25 m
pc = 0,5 m
pc = 0,05 m
pc = 0,09 m

Total

pc = 6,5 m.

Hga
4.93.180.1

100 Pipe
5 m Length

Considering that the calculation has been made for new pipes, an
increase of 15/20% is to be applied for ageing etc. Therefore the
total head loss p amounts to about 8 m.
Therefore, the total manometric head which the pump must achieve is:

Foot valve

Hmt = Hg + p = Hgp + Hga + pc = 39 + 3,5 + 8 = 50,5 m total.


The pump type NM 50/20AE can be chosen (see pump diagram)

Case B

Istallation data

- Q (Flow) = 42 m3/h
- Hga (geometric head inlet) = 3,5 m
- Hgp (geometric head outlet) = 39 m
- 5 m DN 100 mm diameter suction pipe complete with 1 gate valve
and 1 foot valve
- 70 m DN 80 mm diameter delivery pipe with 1 non-return valve, 1
gate valve and 3 sweep elbows

B) Operation under positive suction head

Hg

Hg = Hgp - Hga = 39 - 3,5 = 35,5 m Geometric head of the installation


pc = total head loss
Suction side:
5 m 100 piping
1 Non-return valve
1 Gate valve

Hgp
80 Pipe
70 m Length

pc = 0,12 m
pc = 0,5 m
pc = 0,05 m

Hga

Delivery side:
70 m 80 pipe
1 Non-return valve
1 Gate valve
3 Elbows

pc = 5,25 m
pc = 0,5 m
pc = 0,05 m
pc = 0,09 m

Total

pc = 6,5 m

4.93.100

100 Pipe
5 m Length

Considering that the calculation has been made for new pipes, an
increase of 15/20% is to be applied for ageing etc. Therefore the
total head loss pc amount to about 8 m.
Therefore, the total manometric head which the pump must achieve is:
Hmt = Hg + p = Hgp - Hga + pc = 39 - 3,5 + 8 = 43,5 m total.
The pump type NM 50/20BE can be chosen (see pump diagram)

332

How to select a centrifugal pump

ACCESSORIES FOR WATER SUPPLY


Foot valve with strainer - Sealing member installed on the lower end of the suction pipe. It prevents the water coming out from the
piping and pump at every plant stop. It must be always immersed in the fluid at an installation depth which allows a perfect operation
without cavitation.
It is a good rule to also install a float switch to automatically stop the pump when the water goes below a fixed level.
Non-return valve - It must be installed on the pump delivery port to avoid reflux in case of a sudden stop of the plant. It is recommended using a type fitted with an inner return spring and with ogive shutter, as this will help to diminish water hammering.
Gate valve - The installation of a gate valve is very important. In addition to allowing the pump to be dissasembled without emptying
the plant, it is used to start the plant and to adjust the flow.

PIPING
The piping must be selected in-line with the water velocity which is recommended to be 1.5 meter per second on the suction side and
3 meter per second on the delivery side. The calculation of the suction piping must be carefully checked so as to avoid the maximum
head loss and allow the pumps maximum suction capability. The piping must be perfectly tight and have no counterslopes towards the
pump port, so to avoid the development or entrapment of air bubbles or pockets.
All the piping must be secured to rests, so that they will not weigh on the pump ports.

Problems at the pump


Faults

Possible causes

Jammed pump

This may happen after periods of inactivity due to inner oxidation.


To release smaller sized monobloc electropumps use a screwdriver at the notch on the back part
of the shaft.
For the larger sizes, turn on the shaft or the flexible coupling

Pumps which do not prime

Pump and/or suction pipe with air entraped.


Uncomplete priming or totally unprimed.
Possible air entering from taps, drain or fill plugs, joints or stuffing box
Foot valve not fully immersed in the fluid or obstructed by deposits.
Suction lift too high compared with the capability of the pump.
Wrong direction of rotation
Wrong number of revolutions

Insufficient flow

Piping and accessories of too small a diameter which cause too high head loss.
Jammed impeller with presence of debris in the vanes.
Corroded or broken impeller
Impeller wear rings and/or pump casing worn by abrasion.
Gas presence in the water, or too high fluid viscosity in case of fluids different from water.

Noise and vibrations in the


pump

Unbalanced rotary part or worn ball bearings.


Pump and piping not properly secured.
Too low flow rate for the selected pump
Operation with cavitation

Overloaded motor

Pump characteristics higher than those of the plant


Fixed and rotary parts in contact tending to seize owing to a lack of lubrication
Too high rotation speed
Wrong mains supply
Poor unit allignement
Fluid with too higher density than the design

333

45

How to select a centrifugal pump


Table no. 1
Head loss in m for steel pipes
Q m3/h

12

18

24

30

36

42

48

mm Q l/min

16

50

100

150

200

300

400

500

600

700

800 1000 1500 2000 3000 4000 5000 6000 7000

Tubo
G

60

90

120

180

240

300

360

420

DN 25

2,7

21

80

0,6

1,7

3,5

G 1 1/4 DN 32

0,7

5,5

22

47

75

0,35

2,1

3,1

G 1 1/2 DN 40

1,8

14

23

50

90

0,7

1,35

1,9

2,5

3,8

5,2

G2

DN 50

0,5

2,2

17

28

45

62

0,4

0,8

1,25

1,5

2,5

3,2

4,1

G 2 1/2 DN 65

0,6

1,2

2,1

4,2

12

17

22

28

45

0,5

0,75

1,4

2,5

3,4

G1

DN 80

HL
v

0,8

1,6

2,8

4,2

6,5

7,5

10,5

15

32

50

0,7

0,95

1,25

1,6

2,1

2,6

3,3

4,9

0,55

0,9

1,4

2,4

3,5

11

20

40

m/100m
m/s
DN 125

0,6

0,8

1,1

1,25

1,4

1,6

3,2

0,9

1,2

1,8

6,5

15

23

0,95

1,1

1,4

2,7

5,2

DN 150

0,6

1,5

2,5

14

20

0,9

1,4

1,7

2,7

3,5

4,8

5,6

DN 200

0,4

0,6

1,3

3,5

4,6

6,5

0,8

1,6

2,6

3,5

0,7

1,1

1,6

DN 100

DN 250

0,4
1

1,3

1,6

2,3

DN 300

0,3

0,45

0,7

0,9

0,9

1,25

1,4

1,6

Q Flow.

HL Head loss, m per 100 m.

v = Flow velocity: max 1,5 m/s for suction and 3 m/s for delivery.

Table no. 2
Head loss in cm for bends, gate valves, foot valves and check valves

Water
flow
velocity

= 90 sweep elbow
R

Elbows
= 30

= 40

= 60

= 80

= 90

0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0

0,43
0,67
0,97
1,35
1,7
2,2
2,7
6,0
11
17
25
33
43
55
67

0,52
0,81
1,2
1,65
2,1
2,7
3,3
7,3
14
21
30
40
52
67
82

0,71
1,1
1,6
2,2
2,8
3,6
4,5
10
18
28
41
55
70
90
110

1,0
1,6
2,3
3,2
4,0
5,2
6,4
14
26
40
60
78
100
130
160

1,2
1,9
2,8
3,9
4,8
6,2
7,6
17
31
48
70
93
120
160
190

Foot
valves

Check
valves

0,23
0,37
0,52
0,70
0,95
1,20
1,45
3,3
5,8
9,1
13
18
23
37
52

32
33
34
35
36
37
38
47
61
78
100
123
150
190
220

31
32
32
32
33
34
35
40
48
58
71
85
100
120
140

d
d
d
d
= 0,4
= 0,6
= 0,8
R
R
R

m/sec.

Gate
valves

0,11
0,18
0,25
0,34
0,45
0,57
0,7
1,6
2,8
4,4
6,3
8,5
11
14
18

0,13
0,21
0,29
0,40
0,53
0,67
0,82
1,9
3,3
5,2
7,4
10
13
21
29

334

0,16
0,26
0,36
0,48
0,64
0,82
1,0
2,3
4,0
6,3
9
12
16
26
36

d
=1
R

d
= 1,5
R

0,23
0,37
0,52
0,70
0,93
1,18
1,45
3,3
5,8
9,1
13
18
23
37
52

0,43
0,67
0,97
1,35
1,7
2,2
2,7
6
11
17
25
33
42
55
67

How to select a centrifugal pump


Table no. 3
Diagram of manometric suction head with water up to 100 C

POSITIVE SUCTION HEAD


(mwc)

WATER TEMPERATURE IN DEGREES CELCIUS


5

10

20

40

30

50

60

70

80

90

100

110

60

70

80

90

100

110

4
3
2
1
0
1
2

MANOMETRIC SUCTION LIFT


(mwc)

3
4
5
6

PRAC

TI C A

E
RV
U
C

7
8
9

THE

CU
CA L
I
T
E
R
O

RVE

10
11

10

20

30

40

50

WATER TEMPERATURE IN DEGREES CELCIUS

Diagram referred to pumps with manometric suction head of 7 mwc. at 20 C

45
335

Catalogue

60Hz

May 2010 C139-7/2


Changes reserved

Вам также может понравиться