Вы находитесь на странице: 1из 1

Applied

Rating (1)

Frame (2)

Table 15 AC Input Protection Devices


Drive Sized For Normal
Duty
Output
Overload
Continuous Catalog
Number
Amps
Output
Amps
(x = F or G) 60 sec 3 sec

Drive Sized For Heavy


Duty
Output
Catalog
Overload
Number
Amps
(x = F or G) 60 sec 3 sec

Input
Quantities

AC Input Protection Devices


Dual Element
Continuous
Time Delay
Non-Time
AC Input
Fuse
Delay Fuse
(3)
(4)
kVA
Amps Min
Max
Min(3) Max(4)

Input
Quantities
Circuit
Breaker
Max
Size(5)

Motor
Circuit
Protector 140M Motor Starter with Adjustable Current
(6)
Range (7) (8)

20xC015
20xC022
20xC030
20xC037
20xC043
20xC060
20xC072
20xC085
20xC104
20xC140
20xC170
20xC205
20xC260
20xC302
20xC367
20xC456

17.3
24.2
33.0
45.0
55.5
66.0
90.0
108.0
127.5
156.0
210.0
255.0
307.5
390.0
453.0
550.5

23.1
33.0
45.0
55.5
66.6
90.0
108.0
129.6
156.0
210.0
255.0
307.5
390.0
468.0
550.5
684.0

7.4
10.1
14.6
19.9
24.5
28.5
39.8
48.9
57.7
71.3
95.0
115.4
139.1
176.5
205.0
249.1
309.5

10.7
14.6
21.1
28.7
35.4
41.2
57.4
70.5
83.3
102.9
137.2
166.5
200.8
254.7
295.9
359.5
446.7

15
20
30
40
45
55
75
90
110
130
175
225
275
325
400
475
600

25
30
45
60
80
90
125
150
175
225
300
375
450
575
675
800
1000

15
20
30
40
45
55
75
90
110
130
175
225
275
325
400
475
600

45
60
80
120
125
150
225
275
325
400
550
600
600
750
900
1000
1800

45
60
80
100
110
120
180
200
250
300
400
500
600
700
900
1100
1300

15
20
30
50
50
60
100
100
150
150
250
250
400
400
600
600
600

M-C2E-C16 M-D8E-C16 M-F8E-C16


M-C2E-C20 M-D8E-C20 M-F8E-C20
M-C2E-C25 M-D8E-C25 M-F8E-C25
M-F8E-C32
M-F8E-C45

6.8
9.2
13.3
18.1
22.3
26.0
36.2
44.5
52.5
64.9
86.5
105.1
126.7
160.7
186.7
226.9
281.9

20xD014
20xD022
20xD027
20xD034
20xD040
20xD052
20xD065
20xD077
20xD096
20xD125
20xD156
20xD186
20xD248
20xD302
20xD361
20xD415

16.5
24.2
33.0
40.5
51.0
60.0
78.0
97.5
115.5
144.0
187.5
234.0
279.0
372.0
453.0
541.5

21.0
33.0
40.5
51.0
61.2
78.0
97.5
117.0
144.0
187.5
234.0
280.8
372.0
453.0
543.6
649.8

7.9
10.4
16.6
20.6
25.9
30.5
39.7
49.6
60.1
74.9
97.6
121.8
145.2
193.6
235.7
281.8
323.9

9.5
12.5
19.9
24.8
31.2
36.7
47.7
59.6
72.3
90.1
117.4
146.5
174.6
232.8
283.5
338.9
389.6

15
17.5
30
35
45
50
65
90
100
125
175
200
250
325
400
475
525

20
30
50
60
75
90
110
125
170
200
275
350
400
550
675
800
900

15
17.5
30
35
45
50
65
90
100
125
175
200
250
325
400
475
525

40
55
80
100
125
150
200
250
300
375
500
600
600
700
900
1000
1200

40
50
80
100
100
120
150
175
225
275
375
450
550
700
900
1000
1200

15
20
30
50
50
50
70
100
100
125
250
250
250
400
600
600
600

M-C2E-C16 M-D8E-C16 M-F8E-C16 CMN-2500


M-C2E-C16 M-D8E-C16 M-F8E-C16 CMN-4000
M-C2E-C25 M-D8E-C25 M-F8E-C25 CMN-4000
M-F8E-C32 CMN-4000
M-F8E-C45 CMN-6300
M-F8E-C45 CMN-9000
CMN-9000
CMN-9000

7.2
9.5
15.1
18.8
23.6
27.8
36.1
45.1
54.7
68.3
88.9
110.9
132.2
176.3
214.7
256.6
295.0

400 Volt AC Input


2
2
2
3
3
3
4
4
5
5
6
6
6
6
7
7
7

11.5
15.4
22
30
37
43
60
72
85
104
140
170
205
260
302
367
456

540 Volt DC Input


20xC015
20xC022
20xC030
20xC037
20xC043
20xC060
20xC072
20xC085
20xC104
20xC140
20xC170
20xC205
20xC260
20xC302
20xC367
20xC456

16.9
24.2
33.0
40.7
47.3
66.0
79.2
93.5
114.4
154.0
187.0
225.5
286.0
332.2
403.7
501.6

23.1
33.0
45.0
55.5
64.5
90.0
108.0
127.5
156.0
210.0
255.0
307.5
390.0
453.0
550.5
684.0

480 Volt AC Input


7.5 Hp
10 Hp
15 Hp
20 Hp
25 Hp
30 Hp
40 Hp
50 Hp
60 Hp
75 Hp
100 Hp
125 Hp
150 Hp
200 Hp
250 Hp
300 Hp
350 Hp

2
2
2
3
3
3
4
4
5
5
6
6
6
6
7
7
7

11
14
22
27
34
40
52
65
77
96
125
156
186
248
302
361
415

Continuous DC
Input
Non-Time Delay
kW
Amps Fuse
12.6
17.0
24.6
33.6
41.4
48.1
67.1
82.4
97.3
120.2
160.3
194.6
234.7
297.7
345.7
420.2
522.0

HSJ20
HSJ25
HSJ40
HSJ50
HSJ70
HSJ90
HSJ100
HSJ125
HSJ150
HSJ175
HSJ250
HSJ350
HSJ350
HSJ400
Bussman 170M6608
Bussman 170M6612
Bussman 170M6613

650 Volt DC Input


20xD014
20xD022
20xD027
20xD034
20xD040
20xD052
20xD065
20xD077
20xD096
20xD125
20xD156
20xD186
20xD248
20xD302
20xD361
20xD415

15.4
24.2
29.7
37.4
44.0
57.2
71.5
84.7
105.6
137.5
171.6
204.6
272.8
332.2
397.1
456.5

21.0
33.0
40.5
51.0
60.0
78.0
97.5
115.5
144.0
187.5
234.0
279.0
372.0
453.0
541.5
622.5

11.1
14.7
23.3
28.9
36.4
42.9
55.7
69.7
84.5
105.3
137.1
171.2
204.1
272.1
331.3
396.1
455.3

HSJ20
HSJ30
HSJ40
HSJ50
HSJ60
HSJ80
HSJ90
HSJ100
HSJ150
HSJ175
HSJ200
HSJ300
HSJ400
HSJ400
Bussman 170M6608
Bussman 170M6612
Bussman 170M6612

Notes:

(1) Applied Rating refers to the motor that will be connected to the drive. For example, a C015 drive can be used in Normal Duty mode on a 7.5 kW motor, or in Heavy Duty mode on a 5.5 kW motor. The drive can be
programmed for either mode. Wiring and fuses can be sized based on the programmed mode. For any given drive catalog number, Normal Duty mode provides higher continuous current but smaller overload current with
respect to Heavy Duty mode. See parameter 306 [Duty Rating].
(2) Enclosure codes F and N only. See Table 8 for frame sizes of other enclosure types.
(3) Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping.
(4) Maximum protection device size is the highest rated device that supplies drive protection. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum.
(5) Circuit Breaker - inverse time breaker. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum.
(6) Recommended Motor circuit protector - Instantaneous trip circuit breaker. The trip setting should be set to the input current of the drive and should be sized for the continuous current of the system.
(7) Bulletin 140M with adjustable current range should have the current trip set to the minimum range that the device will not trip.
(8) Manual Self-Protected (Type E) Combination Motor Controller. 480Y/277V and 600Y/347V AC Input.

43

PowerFlex 750-Series Installation Instructions Publication 750-IN001A-EN-P December 2008

5.5 kW
7.5 kW
11 kW
15 kW
18.5 kW
22 kW
30 kW
37 kW
45 kW
55 kW
75 kW
90 kW
110 kW
132 kW
160 kW
200 kW
250 kW

DC Input
Protection

Вам также может понравиться