PMC200 Multifunctional Power Meter

7 Ave. 19 y 20 Calle S.O., Bo. Prado Alto, P.O. Box: 1824 San Pedro Sula, Honduras, C. A. Telefax: (504) 556-8171, 556-6689 E-mail: info@cei.hn Controles Elctricos Industriales

www.cei.hn

Introduction

PMC200 Multifunctional Power Meter is widely used for energy management system, substation automation, distribution network automation, subdistrict power distribution, industrial automation, intelligent building, intelligent switchboard, switch cabinet, etc. It integrates the digitization, intellectualization and networking together, to replace the traditional equipments such as electric quantity transducer, numeric display instrument, data acquisition unit and recorder analyzer, etc. The multi-purpose lows the cost, and the simple wire connection simplifies the testing. Standard: DL/T721 - 2000 Voltage and current Power Accuracy class Active electrical degree Range Input voltage characteristic Impedance Allowed overload capacity Range: Input current characteristic Impedance: Allowed overload capacity: Contact capacity of relay Communications interface Communication protocol Electromagnetic compatibility Insulation resistance Power frequency withstand voltage Whole power Power supply Working temperature Dimensions 96x96x120(mm)(with expanding module) Weight 0.5 kg 5VA 90 to 260VAC/DC -20 ~ +70 96x96x72 (mm), 220VAC/5A, 30VDC/5A RS485, baudrate optional, Max. 19200bps MODBUS RTU Conforms to Class IEC 50M AC2kV/1min Class 0.2 Class 0.5 Class 1 100V, 200V, 400V (optional) 2M (L-L), 1M (L-N) 1.2 times/ continuous 1A, 5A (optional) 0.1 1.2 times/ continuous, 10 times/1 second

PMC200 Power Parameter Tester

7 Ave. 19 y 20 Calle S.O., Bo. Prado Alto, P.O. Box: 1824 San Pedro Sula, Honduras, C. A. Telefax: (504) 556-8171, 556-6689 E-mail: info@cei.hn Controles Elctricos Industriales

www.cei.hn

Functions and Features


Parameter Measurement Power Quality Harmonic Distortion lysis Current / Voltage Current and Voltage Active/Reactive/Apparent Power Power Factor / Frequency Phase and Neutral Line Wire Line and Phase Line 3 Phases and Single Phase 3 Phases and Single Phase Energy Measurement Input/Output Active Energy Input/Output Reactive Energy Apparent Energy 1 Channel Pulse Output 1 Channel Pulse Output Demand Statistics Current Active/Reactive/Apparent Power Current Value and Max. Current Value and Max. Restoration Rate 8 Restoration Stages; 4 Restoration Rate can be set Maximum and Minimum Record the maximum, minimum and 1 Channel Analog Input Measurement for 05V DC 2 Channels Analog Output for 4-20mA DC Communication Module Others Update on-line Remote Communication Input Module 8 Channels Remote Communication Input Resolution of State Variable Time: up to 1 ms 100 SOE Events Log Relay Output Module 4 Channels Relay Output Programmable Alarm Setting of exceeding the li mit Remote Control Analog Input and Output Module 1 Channel Analog Input Measurement for 420mA DC STN LCD Display with big screen / RealTime Clock Year/Month/ Day/Hour/Minute/Second RS485/MODBUS Display / Current and Voltage Communication Protocol / 31 times Harmonic Ana

7 Ave. 19 y 20 Calle S.O., Bo. Prado Alto, P.O. Box: 1824 San Pedro Sula, Honduras, C. A. Telefax: (504) 556-8171, 556-6689 E-mail: info@cei.hn Controles Elctricos Industriales

www.cei.hn

time of all measurement parameters Event Log

a)RS232 Communication Module b)Profibus-DP Communication Module

100 SOE Events Log / Time Resolution: up to c)TCP/IP Ethernet Expansion Module 1 ms