PCS0911

AIR CONDITIONING SYSTEM COOLING ONLY [50Hz ]

The match for tastefully designed offices and stores.

Peo p le a re d ra wn to b e a u tifully des igned s tores that ex pres s the lates t. Peo p le wo rk b e st in o ffice s imbued with func tional beauty. D a ikin s SkyAir is th e ch o ice to bring high quality air c onditioning to st ore s a n d o ffice s like th is. Th a n ks to its ma n y a d va n ta g es s uc h as quiet operation, eas e of us e and f l exib le in sta lla tio n , th e SkyAir enjoy s an ex c ellent reputation throughout t he wo rld wh e re ve r it is u se d.

Cooling only
HP
1 Capacity * The values given for 2 HP6 HP is for FHC type, 6.5 HP7 HP is for FDMG type.

2 18,000
5.3 4,560

2.5 21,000
6.2 5,290

3 26,000
7.6 6,550

3.5 30,000
8.8 7,570

Btu/h kW kcal/h

CEILING MOUNTED CASSETTE TYPE


Indoor unit Outdoor unit

FHC18NUV1
R18NUV1

FHC21NUV1
R21NUV1

FHC26NUV1
R26NUV1 / Y1

FHC30NUV1
R30NUV1 / Y1

CEILING SUSPENDED TYPE


Indoor unit Outdoor unit

FH21NUV1
R21NUV1

FH26NUV1
R26NUV1 / Y1

FH30NUV1
R30NUV1 / Y1

LOW STATIC PRESSURE TYPE


Indoor unit

FDBG18NUV1
R18NUV1

FDBG21NUV1
R21NUV1

FDBG26NUV1
R26NUV1 / Y1

DUCT CONNECTION

Outdoor unit

MIDDLE STATIC PRESSURE TYPE


Indoor unit Outdoor unit

FDMG26NUV1
R26NUV1 / Y1

FDMG30NUV1
R30NUV1 / Y1

OUTDOOR UNIT
R18NUV1 R21NUV1 R26NUV1 / Y1 R30NUV1 / Y1

*1. Note : Rated cooling capacities are based on the following conditions: Return air temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal)

CEILING SUSPENDED TYPE


Simple design and qui et operation auto-swing air flow brings comfort to each and every corner of the room. Installation and maintenance are easy.

DUCT CONNECTION TYPE


The indoor unit i s ins talled inside the ceiling and duc ts discharge air in any dir ec tion. Comfort is provided w ithout provi ded even knowing that an air conditioner is ins talled.

CEILING MOUNTED CASSETTE TYPE


Th i s u n it is in st a lle d a t ce n t e r c e i l i n g. A ir is b lo wn in f o u r d i r e c t iion s t o b rin g co mf o rt . o O p e r at io n is q u ie t .

4 36,000
10.6 9,100

5 42,000
12.3 10,600

6 48,000
14.1 12,100

6.5 51,000
15.0 12,900

7 56,000
16.4 14,100

FHC36NUV1
R36NUV1 / Y1

FHC42NUV1
R42NUY1

FHC48NUV1
R48NUY1

FH36NUV1
R36NUV1 / Y1

FH42NUV1
R42NUY1

FH48NUV1
R48NUY1

FDMG36NUV1
R36NUV1 / Y1

FDMG42NUV1
R42NUY1

FDMG48NUV1
R48NUY1

FDMG51NUV1
R51NUY1

FDMG56NUV1
R56NUY1

R36NUV1 / Y1

R42NUY1

R48NUY1

R51NUY1

R56NUY1

CEILING MOUNTED

CASSETTE TYPE

Quiet, decor-blending form and easy installation in new or old buildings.

FHC-NU

Sound level

Cooling only

FHC18NU48NU

42/36
High

Low

dB(A)

FHC36NU
(220V)

Option
Accessory required for indoor unit

Wired LCD remote controller


BRC1C61
Note: Remote controller cable not included. Cables must be procured locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7C613W
Signal receiver unit (Installed type)
Wireless remote controller and signal receiver unit are sold as a set.

Features
Feature
Swing pattern selection

Comfort
High ceiling application Switchable fan speed

Mould prevention

Work & Servicing


Ceiling soiling prevention Drain pump mechanism

Control features

Mould resistant treatment for filter

Two selectable temperature-sensors

Ultra long-life filter

High-efficiency filter

Auto swing

Model Cooling only

*1

*2

*1Applicable when wired remote controller is used *2Applicable to R36NUR48NU outdoor units

Fresh air intake kit

Programme "Dry"

Pre charged for up to 15 m

Timer selector

Long-life filter

Auto-restart

Filter sign

Unified square panels


All models from the 18NU to 48NU use the same size panel. Multiple unit installations maintain a physical uniformity that is aesthetically pleasing and make it easier to plan ceiling lighting systems and to design interiors.

Compact body and quiet operation


Indoor units use an aerodynamically designed Diffuser Turbo Fan
Diffuser

Draft resistance has been reduced by incorporating, into a single unit, an impeller and a diffuser to control air flow inside the unit. The Diffuser Turbo Fan is both quiet during operation and compact.
Indoor unit High Low

(220V) dB(A)

950 mm

Same for all models

Blade

950 mm

18NU 21NU 26NU 30NU 36NU 42NU 48NU

33 35 35 39 42 42 42

29 30 30 34 36 36 36

Optimal comfort and convenience assured by 3 air discharge modes


Air direction
Desired situation

Quick and easy to install


Just 240 mm high. Installable in tight ceiling spaces (18NU26NU)
240 mm *1 245 mm *2

Draft prevention setting


When drafts are unwanted
Auto-swing between 10 and 40 Settable to 5 different levels between 10 and 40

Standard setting
For gentle drafts(Ceiling is soiled.)
Auto-swing between 10 and 65 Settable to 5 different levels between 10 and 65

Setting to prevent soiling of ceiling


When ceilings must be kept spotless
Auto-swing between 30 and 65 Settable to 5 different levels between 30 and 65
At heating startup and thermo OFF*, air discharge is automatically set to 30 to prevent both direct exposure to cool air drafts and contact with ceilings.

Auto-swing 5-levels air direction setting Draft prevention (In heating mode) Auto air direction control

At heating startup and thermo OFF*, air discharge is automatically set to a near horizontal 10 to prevent direct exposure to cool air drafts.

The air direction is set automatically to the memorised position of the previous air direction. (Initial setting is 65 for heating and 30 for cooling.)

*1 298 mm high with 30NU48NU *2 303 mm high with 30NU48NU

Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.

Easy height adjustment Wide air distribution


A newly shaped air discharge opening increases flow without increasing wind speed, hence discharged air reaches farther than before.
Air discharge distribution comparison
42NU

*When the thermostat turns off.

Multi-Flow System
4-way flow
1 pattern

Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height.
Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets.

3-way flow
4 pattern

Super Cassette

2-way flow
3 pattern
" " denotes piping direction. " " denotes sealing member for air discharge outlet (option) . Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s).

(m) Conventional model 2.7 2.5 m/sec 2.0 m/sec 2 1.5 m/sec 1.0 m/sec 1 0.5 m/sec 4 (m) 3 2 1 0 1

(m) 3.2 3

2.5 m/sec 2 2.0 m/sec 1.5 m/sec 1.0 m/sec 1 0.5 m/sec 2 3 4 (m)

All models suspended without lift Installable in any direction

Suitable for high ceilings


Criteria for ceiling height and number of air discharge outlets
Number of air discharge outlets used

Air direction can be selected according to installation.


Note: Operation sound increases when using 2-way or 3-way flow.

18NU26NU
4-way flow Standard Ceiling High ceiling height High ceiling 3-way flow 2-way flow

30NU48NU
4-way flow 3-way flow 2-way flow

2.7 m 3.0 m 3.5 m 3.2 m 3.6 m 4.2 m 3.0 m 3.3 m 3.8 m 3.6 m 4.0 m 4.2 m 3.5 m 3.5 m 4.2 m 4.2 m -

Provided with drain pump mechanism Easy installation of options


The high-performance filter and other options are easily clipped into place. There is no need for a screwdriver.
750 mm

Note: Initial settings are for standard ceiling height and 4-way flow. High ceiling settings 1 and 2 are set from the remote controller.

Two selectable temperature-sensors


Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.

Programme "Dry"
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.

Switchable fan speed: High/Low

CEILING SUSPENDED TYPE

Upgrade to a quiet and compact system.

FH-NU

Sound level

Cooling only

FH21NU48NU

46/40
High

Low

dB(A)

FH36NU
(220V)

Option Accessory required for indoor unit

Wired LCD remote controller


BRC1NU61
Note: Remote controller cable not included. Cables must be procured locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7NU66

Signal receiver unit (Installed type)


Wireless remote controller and signal receiver unit are sold as a set.

Features
Feature

Comfort
Mould resistant treatment for filter Switchable fan speed

Mould prevention

Work & Servicing

Control features

Programme "Dry"

Mould proofing drain pan

Pre charged for up to 15 m

Timer selector

Long-life filter

Model Cooling only

*1

*1Applicable to R36NUR48NU outdoor units

Auto-restart

Auto swing

Spreads comfortable air throughout the room


Auto-swing (up&down) brings comfort to the room. Wide air discharge openings produce a spreading 100 airflow Installable on ceilings 3.5 m high

Quiet operation
Sound operation has been reduced on the exposed ceiling suspended type unit.
(220V) dB(A)

Indoor unit

High

Low

21NU

Switchable fan speed: High/Middle/Low Programme "Dry"

26NU 30NU 36NU 42NU 48NU

44 44 45 46 48 49

40 40 40 40 42 43

100

Air is blown up to 50 in the downward direction.

Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.

Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.

Uses quiet stream fan and other quiet technologies.

50

Turbulent flow Straightening is produced vane

Quiet stream fan

Installation flexibility for freedom of design


Uniform height and depth. Compact design for smallcapacity models to meet tighter dimensional constraints.
(mm)

Easier to maintain
Long-life filter lasts about half year * maintenance not required
* For dust concentration of 0.15 mg/m
3

All wiring and internal servicing done from below the unit Pipes more easily rigged, too
Plastic panels are used to conceal piping holes. Holes can be easily punched out without requiring special tools.

Non-dew flap without bristles


Absence of bristles minimises clinging dirt and simplifies cleaning.
Non-dew flap

Indoor unit 21NU 26NU 30NU 36NU 42NU 48NU Height Width Depth
195 1,160 1,400 680 1,590

Weight of all models reduced (down 10% compared with previous models). Transfer and installation work is less arduous.

Easy-clean, flat surfaces


It is easy to wipe dirt off the flat side and lower surfaces of the unit.

Reduced edge space, flexible installation


The unit fits more snugly into tight spaces.
For 48NU indoor unit

For all maintenance tasks, access is from bottom surface

30 mm
or more

1,590 mm

30 mm
or more

Improved-oil resistant grille


Oil-resistant plastic is used for the air discharge grille. This improves durability in restaurants and other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.

*Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case.

DUCT CONNECTION

MIDDLE STATIC PRESSURE TYPE

FDMG-NU

Unit can be mounted in the ceiling and air can be delivered freely by duct.
Superior freedom of layout
The duct system allows the efficient location of discharge outlets in accordance with the room layout Middle static pressure type, usable in a larger than standard space Duct connection is simpler with standard rear intake chambers
Ordinary duct (procured locally)

Air conditioner 295 mm

Ordinary duct (procured locally)

Air discharge

305 mm or more Air intake

Quiet operation
(220V) dB(A)

Indoor unit

High

LOW

FDMG26NU FDMG30NU FDMG36NU FDMG42NU FDMG48NU


Sound level

FDMG51NU FDMG56NU

Cooling only

FDMG26NU56NU
Option

45/37dB(A)
High Low

42 44 45 46 46 47 47

38 36 37 37 37 37 37

FDMG36NU
(220V)

Switchable fan speed: High/Middle/Low


Drain pipe connection can be done inside the unit. Coolant and drain pipe outlets are at the same opening.

Accessory required for indoor unit

Digital remote controller

Remote controller

Features
Feature

Comfort
Switchable fan speed

Work & Servicing Control features

Pre charged for up to 15 m

KRC47-2A KRC47-4A

KRC47-1A

Model Cooling only

*1

*1Applicable to R36NUR51NU outdoor units

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Door-installed ventilation grille Wall-installed ventilation grille Under-door cutout

Partitioning wall

Ventilates air through the partitioning wall. (See right) Ventilation grille Ventilation grille Under-door cutout

Note: The under-door cutout method should be used only when there is a small volume of airflow.

Auto-restart

DUCT CONNECTION

LOW STATIC PRESSURE TYPE

FDBG-NU

Ideal for quiet, beautiful living spaces Suitable for condominiums and apartments, houses and hotels
Compact
Small, lightweight, and easy-to-install outdoor unit.

or more

Suction chamber [Duct connection] Air filter

To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber.

Quiet operation
Indoor unit High

(220V) dB(A)

Low

FDBG18NU FDBG21NU FDBG26NU


Sound level

41 43 43

38 40 40

Cooling only

FDBG18NU26NU
Option

43/40dB(A)
High Low

Durable
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.

FDBG26NU
(220V)

Accessory required for indoor unit

Digital remote controller

Remote controller

Features
Feature

Comfort
Switchable fan speed

Work & Servicing Control features

Others

KRC47-2A KRC47-4A

KRC47-1A

Model Cooling only

Adjustable external static pressure

Pre charged for up to 10 m

Auto-restart

OUTDOOR UNIT

R26NU

R30NU

R36NU

R42NU

R48/51NU

Quiet Operation
Fitted with wide inlet fan
(Applies to R26NU51NU)

Compact
Slim-design and low-profile compact outdoor units
(Applies to R26NU51NU)

Installation and maintenance


Pre charged for up to 15 metres (Applies to R36NU51NU)
If refrigerant piping length does not exceed 5m (R56NU), 10m (R18NU,R21NU, R26NU), 15m (R36NU, R42NU, R48NU, R51NU), there is no need for on-site gas charging.
Allowed refrigerant pipe length and level difference
Pre charged *1 Max. length Max. level difference

Fully shaped aerodynamic propellers are designed to push air with a large wing Wide inlet fan surface. This provides both high blow volume and quiet operation with minimal turbulence.

Compactly designed outdoor unit with interior layout optimised for the smooth airflow. Curved Super Aero Grille restricts the spread of exhaust gas and fits in the same space as conventional outdoor units.

R18NU R21NU R26NU R30NU R36NU R42NU

10 m 10 m 10 m 10 m 15 m 15 m 15 m 15 m 5m

(Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 50 m) (Equivalent length 70 m)

30 m 30 m 30 m

15 m 15 m 20m 20m 20 m 20 m 20 m 20 m 30 m

Fitted with Super Aero Grille


(Applies to R26NU51NU)

30 m 30 m 30 m

To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air.

50 500
(mm)

R48NU R51NU R56NU

30 m 30 m 50 m

Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.

Equipped with scroll compressor for quiet operation


(Applies to R36NU56NU)

4-direction piping offers greater layout freedom


(Applies to R26NU56NU)

Smooth running, minimal vibration, low operating sound.


Even less operation sound
(In case of V1: 220V, Y1: 380V) dB(A)

Piping can be run from the front, bottom, right or rear surface according to how the unit is installed.

Takes installation environment into consideration

Durability
Heat exchange fins provided with anti-corrosion treatment
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
Construction Non-treated fin PE fin
Aluminium Hydrophilic film Aluminium Corrosion resistant acrylic resin

Outdoor unit
R30NUV1 R30NUY1 R36NUV1 R36NUY1

Sound level

R42NUY1 R48NUY1 R51NUY1

57 55 57 59 59

Abundance of functions that provide comfortable air-conditioning in stores and offices.


See the list of main functions given on the page introducing each indoor unit.

Comfort
Auto-swing
Delivers comfortable airconditioning to all areas, near to and far from the airconditioner.
Air discharge direction angle can be set (fixed setting)

Work and Servicing


Drain pump mechanism
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.

Pre charged for up to 15 metres Swing pattern selection


(draft prevention, standard, ceiling soiling prevention)

If refrigerant piping length does not exceed 15 m, there is no need for on-site gas charging. (Applies to R36NU51NU)

You can freely set 3 air discharge positions by remote controller.


(1) Air direction range in standard position

Long-life filter
Maintenance is not required for one year (two years when a ceiling mounted cassette type is used).

(2) Air direction range in draft prevention position (3) Air direction range in ceiling soiling prevention position

Ceiling soiling prevention function


Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.

Filter sign
The filter sign warns you when it is time to clean the filter.

Switchable fan speed


High setting provides maximum reach while low setting minimises drafts.

*When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.

Programme "Dry"
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.

Control features
Auto-restart
If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.

High-ceiling application
Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.

Others
PE fin
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out.

Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.

Options
High-efficiency filter unit
Two types are available: 65% and 90% colorimetry.

Timer selector
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.

Ultra long-life filter

Mould prevention
Mould resistant treatment for filter
Sanitary filter has mould resistant treatment.

Requires no maintenance for about 4 years* (10,000 h) in stores and offices. * For dust concentration of 0.15 mg/m3

Fresh-air intake kit


You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending.

Mould proofing drain pan


Mould proofing maintains hygiene by preventing growth in highly humid conditions.

10

CEILING MOUNTED CASSETTE TYPE


Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Btu/h kW kcal/h kW 30 26 48 36 42 FHC30NUV1 FHC26NUV1 FHC48NUV1 FHC36NUV1 FHC42NUV1 R30NUV1 R26NUV1 R36NUV1 R48NUY1 R42NUY1 R18NUV1 R21NUV1 R30NUY1 R26NUY1 R36NUY1 V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz 18,100/18,000 21,200/21,000 26,300/26,000 30,400/30,000 36,500/36,000 42,700/42,000 49,100/48,000 5.3/5.3 6.2/6.2 7.7/7.6 8.9/8.8 10.7/10.6 12.5/12.3 14.4/14.1 4,580/4,560 5,340/5,290 6,630/6,550 7,670/7,570 9,200/9,100 10,800/10,600 12,400/12,100 2.03/2.02 2.46/2.45 3.07/3.07 3.45/3.45 4.04/4.04 4.79/4.79 5.49/5.49 ---------White 15 19 19 28 33 33 33 529 670 670 988 1,164 1,164 1,164 33/29 35/30 35/30 39/34 42/36 42/36 42/36 230X840X840 230X840X840 230X840X840 288X840X840 288X840X840 288X840X840 288X840X840 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950 28 28 24 24 24 28 28 5 5 5 5 5 5 5 14 to 28 Ivory white Ivory Hermetically sealed scroll type Hermetically sealed rotary type 4.50 1.7 2.2 2.5 3.00 2.5 3.75 2.6 1.20 1.50 2.3 2.0 2.3 2.4 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) 18 FHC18NUV1 21 FHC21NUV1

Indoor unit

Power consumption 1a/1b Colour

Outdoor unit

Unit Decoration panel m3/min Airflow rate (H) cfm Sound level (H/L) (220V) 2 dB(A) mm Dimensions Unit (HXWXD) mm Decoration panel kg Unit Machine weight kg Decoration panel CWB Operation range Colour Compressor Type Motor output kW Refrigerant charge (R-22) kg

Sound level 2, 3 Dimensions (HXWXD) Machine weight Operation range Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation

59 57 57 49 54 55 57 dB(A) mm 540X750X270 685X800X300 770X900X320 770X900X320 1,170X900X320 1,170X900X320 1,345X900X320 92 kg 42 61 70 (V1), 69 (Y1) 70 (V1), 69 (Y1) 81 (V1), 79 (Y1) 87 CDB 21 to 46 o 9.5 mm o 6.4 o 6.4 o 9.5 o 9.5 o 9.5 o 9.5 / / / / / / / o 19.1 mm o 15.9 o 15.9 o 15.9 o 15.9 o 19.1 o 19.1 / / / / / / / mm I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 / / / / / / / / / / / / / / mm o 26.0 (Hole) o 18.0 (Hole) o 18.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) / / / / / / / 30 (equivalent length 50 m) m 20 m 15 Both liquid and gas piping

Note : 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1b Indoor temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 In case of V1: 220V, Y1: 380V.

CEILING SUSPENDED TYPE


Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Btu/h kW kcal/h kW m3/min cfm dB(A) mm kg CWB 48 26 30 36 42 FH48NUV1 FH26NUV1 FH30NUV1 FH36NUV1 FH42NUV1 R26NUV1 R30NUV1 R36NUV1 R21NUV1 R42NUY1 R48NUY1 R26NUY1 R30NUY1 R36NUY1 V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz 36,500/36,000 30,400/30,000 42,700/42,000 21,200/21,000 26,300/26,000 49,100/48,000 10.7/10.6 8.9/8.8 12.5/12.3 6.2/6.2 7.7/7.6 14.4/14.1 9,200/9,100 7,670/7,570 10,800/10,600 5,340/5,290 6,630/6,550 12,400/12,100 5.50/5.50 2.72/2.71 3.48/3.48 4.06/4.06 4.83/4.83 3.10/3.10 White 42-44 22-23 26-27 32-34 38-40 22-23 1,482-1,553 776-811 918-953 1,129-1,200 1,341-1,412 776-811 49/43 46/40 45/40 48/42 44/40 44/40 195X1,590X680 195X1,400X680 195X1,590X680 195X1,160X680 195X1,160X680 195X1,590X680 35 26 26 32 35 35 14 to 28 Ivory white Ivory Hermetically sealed scroll type Hermetically sealed rotary type 4.50 2.2 2.5 2.5 3.00 3.75 2.6 1.50 2.3 2.3 2.0 2.4 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) 21 FH21NUV1 54 685X800X300 61 o 6.4 / o 15.9 / I.D o 20XO.Do 26 / / o 18.0 (Hole) / 15 57 770X900X320 70 (V1), 69 (Y1) o 9.5 / o 15.9 / I.D o 20XO.Do 26 / / o 26.0 (Hole) / 57 55 770X900X320 1,170X900X320 70 (V1), 69 (Y1) 81 (V1), 79 (Y1) 21 to 46 o 9.5 o 9.5 / / o 15.9 o 19.1 / / I.Do 20XO.D o 26 I.D o 20XO.D o 26 / / / / o 26.0 (Hole) o 26.0 (Hole) / / 30 (equivalent length 50 m) 20 Both liquid and gas piping 57 1,170X900X320 87 o 9.5 / o 19.1 / I.Do 20XO.Do 26 / / o 26.0 (Hole) / 59 1,345X900X320 92 o 9.5 / o 19.1 / I.D o 20XO.D o 26 / / o 26.0 (Hole) /

Indoor unit

Power consumption 1a/1b Colour Airflow rate (H) Sound level (H/L) (220V) 2 Dimensions (HXWXD) Machine weight Operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level Dimensions (HXWXD) Machine weight Operation range Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation
2, 3

Outdoor unit

kW kg dB(A) mm kg CDB mm mm mm mm m m

Note : 1 Rated cooling capacities are based on the following conditions: 1a Indoor temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1b Indoor temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 In case of V1: 220V, Y1: 380V.

11

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE


Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Btu/h kW kcal/h kW m3/min cfm dB(A) mm kg CWB 48 51 30 36 42 26 FDMG26NUV1 FDMG30NUV1 FDMG36NUV1 FDMG42NUV1 FDMG48NUV1 FDMG51NUV1 R30NUV1 R36NUV1 R26NUV1 R48NUY1 R51NUY1 R42NUY1 R30NUY1 R36NUY1 R26NUY1 V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz 26,300/26,000 30,400/30,000 36,500/36,000 42,700/42,000 49,100/48,000 52,200/51,000 12.5/12.3 7.7/7.6 8.9/8.8 10.7/10.6 14.4/14.1 15.3/15.0 10,800/10,600 12,400/12,100 13,200/12,900 6,630/6,550 7,670/7,570 9,200/9,100 3.46/3.46 4.16/4.16 5.55/5.55 5.90/5.90 3.15/3.15 4.84/4.84 ---------42 42 34 37 42 23 1,482 1,482 1,200 1,306 1,482 811 46/37 47/37 44/36 45/37 46/37 42/38 305X1,350X680 305X1,550X680 305X1,550X680 305X1,550X680 305X1,550X680 305X1,900X680 43 51 52 52 52 58 14 to 28 Ivory Hermetically sealed rotary type Hermetically sealed scroll type 4.50 4.50 2.5 3.00 3.75 2.5 2.3(Charged for 10 m) 2.3(Charged for 10 m) 2.0(Charged for 15 m) 2.4(Charged for 15 m) 2.6(Charged for 15 m) 2.7 (Charged for 15 m) 59 59 57 57 57 55 770X900X320 1,170X900X320 1,170X900X320 1,345X900X320 1,345X900X320 770X900X320 87 92 93 70 (V1), 69 (Y1) 70 (V1), 69 (Y1) 81 (V1), 79(Y1) 21 to 46 o 9.5 o 9.5 o 9.5 o 9.5 o 9.5 o 9.5 / / / / / / o 15.9 o 19.1 o 19.1 o 19.1 o 19.1 o 15.9 / / / / / / 3/4B (I.Do 21.6XO.Do 27.2) / / o 26.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) o 26.0 (Hole) / / / / / / 30 (equivalent length 50 m) 20 Both liquid and gas piping 56 FDMG56NUV1 R56NUY1 57,000/56,000 16.7/16.4 14,400/14,100 6.45/6.45 42 1,482 47/37 305X1,900X680 58

Indoor unit

Power consumption 1a/1b Colour Fan Airflow rate (H)

Sound level (H/L) (220V) 2 Dimensions (HXWXD) Machine weight Operation range Colour Outdoor Compressor Type unit Motor output Refrigerant charge (R-22) Sound level 2, 3 Dimensions (HXWXD) Machine weight Operation range Piping Liquid (Flare) connections Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation

kW kg dB(A) mm kg CDB mm mm mm mm m m

4.50 2.8 (Charged for 5 m) 56 1,345X880X370 114 o 9.5 / o 19.1 / o 26.0 (Hole) / 50 (equivalent length 70 m) 30

Note : 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1b Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 In case of V1: 220V, Y1: 380V.

DUCT CONNECTION LOW STATIC PRESSURE TYPE


Model Name Power supply Cooling capacity 1a/1b Indoor unit Outdoor unit Btu/h kW kcal/h kW m3/min cfm dB(A) mm kg CWB 26 FDBG26NUV1 R26NUV1 R18NUV1 R21NUV1 R26NUY1 V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz 18,100/18,000 21,200/21,000 26,300/26,000 5.3/5.3 6.2/6.2 7.7/7.6 4,580/4,560 5,340/5,290 6,630/6,550 2.12/2.11 2.73/2.72 3.33/3.33 ---------18 18 13 635 635 458 Direct drive (2 speed) 43/40 43/40 41/38 260X900X580 260X1,300X580 260X1,300X580 23 31 31 14 to 28 Ivory white Ivory Hermetically sealed rotary type 2.5 1.7 2.2 2.3 1.20 1.50 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) 49 540X750X270 42 o 6.4 / o 15.9 / o 18.0 (Hole) / 15 Both liquid and gas piping 54 685X800X300 61 21 to 46 o 6.4 / o 15.9 / 3/4B (I.Do 21.6XO.Do 27.2) / / o 18.0 (Hole) / 30 (equivalent length 50 m) 57 770X900X320 70 (V1), 69 (Y1) o 9.5 / o 15.9 / o 26.0 (Hole) / 20 18 FDBG18NUV1 21 FDBG21NUV1

Power consumption 1a/1b Colour Indoor Airflow rate (H) unit Fan Driving system Sound level (H/L) (220V) 2 Dimensions (HXWXD) Machine weight Operation range Colour Compressor Type Motor output Refrigerant charge (R-22) Sound level Dimensions (HXWXD) Machine weight Operation range Liquid (Flare) Piping connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation
2, 3

Outdoor unit

kW kg dB(A) mm kg CDB mm mm mm mm m m

Note : 1 Rated cooling capacities are based on the following conditions: 1a Suction temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1b Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 3 In case of V1: 220V, Y1: 380V.

12

Indoor unit
CEILING MOUNTED CASSETTE TYPE
Type Item Decoration panel Sealing member for air discharge outlet Panel spacer Fresh air intake kit Chamber Without the T-joint pipe and fan type With the T-joint pipe,without fan Direct installation type High-efficiency filter (Colorimetric method 65%) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) High-efficiency filter chamber Replacement long-life filter Ultra long-life filter Replacement ultra long-life filter Branch duct chamber Remote controller Wired type2 Wireless type Central remote controller3 Unified ON/OFF controller3 Schedule timer3 Adaptor for wiring4 Wiring adaptor for electrical appendices3 Interface adaptor for SkyAir series Installation box for adaptor PCB
Note: 1 Required for installing high-efficiency filter or ultra long-life filter. 2 Wiring for wired remote controller to be procured locally. 3 This optional accessory requires DTA102A52. 4 Installation box for adaptor PCB (KRP1B98) is necessary.

FHC18NU

FHC21NU

FHC26NU

FHC30NU

FHC36NU

FHC42NU

FHC48NU

BYC125K-W1, BYC125K-W2 KDBHJ55K160 KDBP55H160WA KDDP55D160 KDDP55D160K KDDJ55X160 KAFP556D80 KAFP557D80 KAFP552H80 KAFP553H80 KDDFP55D160 KAFJ551K160 KAFP55D160 KAFJ55K160H KDJ55K80 BRC1C61 BRC7C613W DCS302CA61 DCS301BA61 DST301BA61 KRP1BA57 KRP4AA53 DTA102A52 KRP1B98 KDJ55K160 KAFP556D160 KAFP557D160 KAFP552H160 KAFP553H160

CEILING SUSPENDED TYPE


Item Replacement long-life filter Resin net L-type piping kit (for upward direction) Wired type1 Remote controller Wireless type
Note: 1 Wiring for wired remote controller to be procured locally.

Type

FH21NU

FH26NU

FH30NU KAFJ501D112

FH36NU

FH42NU

FH48NU

KAFJ501D80 KHFJ5F80

KAFJ501D160 KHFJ5F160

BRC1NU61 BRC7NU66

DUCT CONNECTION
Item

MIDDLE STATIC PRESSURE TYPE


Type FDMG26NU FDMG30NU FDMG36NU FDMG42NU KRC47-1A KRC47-2A KRC47-4A FDMG48NU FDMG51NU FDMG56NU

Remote controller Digital remote controller Digital remote controller for duct heater use

DUCT CONNECTION
Item

LOW STATIC PRESSURE TYPE


Type FDBG18NU FDBG21NU KRC47-1A KRC47-2A KRC47-4A KDGF19A45 KKD19A1 KDGF19A71 FDBG26NU

Remote controller Digital remote controller Digital remote controller for duct heater use Suction grille Drain pan cover

Outdoor unit
Item Drain piping kit Central drain plug Type
R18NU R21NU R26NU R30NU R36NU R42NU R48NU R51NU R56NU

-------------

KIS95

------KKPJ5F180

13

DIMENSIONS
CEILING MOUNTED CASSETTE TYPE

(Unit: mm)

FHC18NUV1 / 21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1


Note3. 950 300 or less C 860~890 Ceiling opening 680 Suspension position 420 780 Suspension position 860~890 Ceiling opening D E 80 2 100=200 85 C 40 350 C view 4-M4 Hole (prepared hole) 75 60 80 80 1500mm or more 1500mm or more 160 B view For fresh air intake kit connection (direct installation type) Required space 1500mm or more 1000 or more Required space 165 1500mm or more When the discharge grill is closeout,the required space is 200mm or more. Branch duct connection B 55 12-M4 Hole (prepared hole) 95 110 125 150 B 240 150 40 350 A Branch duct connection

10

950

6 7
A view 750 Adjustable(0~550) 55 420 55
[FHC18NUV1-26NUV1] 55 840 80 2 100=200 85

3
295

840

40 A 30 10

200

Suspension bolt 4-M8 M10

8 5

260 270 315

A FHC18NUV1-26NUV1 FHC30NUV1-48NUV1

D ----

E ----

230 240 165

[FHC30NUV1-48NUV1] 55 840 80 2 100=200 85


Notes: 1 Location of unit's Name Plate For Main body: Switch Box Cover inside surface of suction grille. For decoration panel: Panel frame inside surface of suction grille. 2 When installing an optional accessory, refer to the installation drawings. For fresh air intake kit Inspection port is necessary. For high efficiency filter unit Inspection port is not necessary. 3 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.

288 298 195 165 195

55

14-M4 Hole (prepared hole) 40 50 155 165


1 Liquid pipe connection 2 Gas pipe connection 3 Drain pipe connection 4 Power supply connection 5 Remote control code and control wiring connection 6 Air discharge grille 7 Air suction grille 8 Port for water supply 9 Corner decoration cover 10 Drain hose

40 350 A

CEILING SUSPENDED TYPE FH21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1


A FH21NUV1 FH26NUV1 FH30NUV1 FH36NUV1 FH42NUV1 FH48NUV1 B

210

1550 1590 1550 1590 1550 1590

50

60

65

(Hanging position)

10
A (Hanging position)

15

105

For height installaion From the floor side 2500 or more 155 5 (Required space)

680

Hanging bolt 4-M8~M10 195

1 5 11
80

Position : Hole of wall for taking out in piping back (View from the front) 90 155 40

13

300 or more (Required space)

55

30 or more (Service space)

B The Front

30 or more (Service space) Brand name plate (Note.2)

4 o 45 /

55

14

Obstacle Floor side Drain pipe connection VP20 (For left piping) 300 275

6
225 275

80
Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 The remote control code is the standard <about 3 m outside the machine> attached. (0.5 mm2 2 wicks O.D. 5.4) (It is attached to VRV.)

80 105 170

1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection 5 Liquid pipe connection 6 Drain pipe conneciton 7 Earth terminal (inside the electric components box) (M4) 8 Suspension bracket 9 Backward piping and wiring connection opening lid 10 Upward piping and wiring connection opening lid 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection

5 135 (Required space)

260

127

Position slit hole for taking out in piping back (View from the front)

65

1360 1400

85 102 160 185 192 36

1120 1160

40 135

115 60

1120 1160

170 105 90 18 17 16 142 58

1000 or more Required space

Branch duct connection

150

195

12

145 60

14

DIMENSIONS
FDMG26NUV1

(Unit: mm)

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

1350 1153 3 680

151

600 (Suspension bolt pinch)

300 or more

427

116 146 381

1203 (Suspension bolt pinch) 1134 1114

126 151 8 16 5 150 263 280


20-M4 Holes

55

Service space

50

7XP150=1050

2 152 212 274

51

1350 1153 1137 1121 7XP150=1050

305 206 175 123

(All around)

(All around)

Note: 1Location of unit's Name Plate: Chamber cap

1 2 3 4 5 6 7 8

Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket

FDMG30NUV1 / 36NUV1 / 42NUV1 / 48NUV1 / 51NUV1 / 56NUV1


A B 151 3 (Suspension bolt pinch) 300 or more

3 600

680

427

116

146

381

C (Suspension bolt pinch)

126 H 151 J K L 51 4 M

55

Service space

D E
50

8 16 2

123

152

212

206

175

274

305

305

150

263 16

74

G (All Around)

827

29

7 N (All Around)

Note: 1Location of unit's Name Plate: Chamber cap

A B C E F D FDMG30NUV1/36NUV1/42NUV1/48NUV1 1550 1353 1403 1334 1314 7XP150=1050 FDMG51NUV1/56NUV1 1900 1703 1753 1684 1664 9XP150=1350

G
18-M4
Holes Holes

22-M4

H J K M L 1550 1353 1337 1321 7XP150=1050 1900 1703 1687 1671 9XP150=1350

N
20-M4
Holes Holes

24-M4

1 2 3 4 5 6 7 8

Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket

15

10

280

74 16 10

18-M4 Holes

727

29

305

DUCT CONNECTION LOW STATIC PRESSURE TYPE FDBG18NUV1 / 21NUV1 / 26NUV1


B A 151 300 or more 10 or more

3
580

500 (Suspension bolt pinch) 137 167 271

317

50

C (Suspension bolt pinch) D E F

126

2
110 170 228

55

Service space

260 164 134 107

5
260 150 219 236 16 10 151 H I J K L M
H 127 102 I J K L M N
Holes Holes

N (All around)
1 2 3 4 Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal 5 6 7 8

29

7
O (All around)

Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap

FDBG18NUV1 FDBG21NUV1/26NUV1

A B C F D E 900 704 755 684 664 3XP150=450 1300 1104 1155 1084 1064 6XP150=900

G 500 700

3XP150=450 674 688 704 900 6XP150=900 1074 1088 1104 1300

10-M4 12-M4
Holes Holes

16-M4 18-M4

52 16 10
O

16

DIMENSIONS
OUTDOOR UNIT R18NUV1
Holes for anchor bolts (M8 or M10) 3-Drain outlets 700 520

(Unit: mm)

190 170

60 27

237 213 48

95

530 750

100

34 72

290 306 15

270

Terminal cover Earth terminal (M4) Power intake Gas stop valve Liquid stop valve

540

Name plate

34

105 Service port

58

27

Minimum space for air passage


150

A 100 50

H Less than 1000 More than 1000

Space A More than 300 More than 600

50 50

R21NUV1
Holes for anchor bolts (M8 or M10) 269

31

540 800

130

98

2-Drain outlet 15 Earth terminal (M4) Power intake 300 Outdoor air thermostat

330 350

H 685 645 Liquid stop valve Service port Gas stop valve 100 95 70 Gas pipe A Name plate Liquid pipe 75

Minimum space for air passage


50 150 H 100

50

50

H H 1000 H 1000

A 300 600

17

OUTDOOR UNIT R26NUV1/Y1 R30NUV1/Y1

Hole for anchor bolt 4-M12


30 350 (345~355) 48 55 140 30 620 900 96 140 40 30 320

3 2 1 6 5 4

6 5 4
55

770

60

329 352

89 142 71

28

89

19 16 58 16

19

80 145

223 53 95 52 13 67

7
70 102 117

4
45 376 191

54 95 84 55

54 95 143

1 Gas pipe connection 2 Liquid pipe connection 3 Grounding terminal M5(in switch box) 4 Refrigerant piping intake 5 Power supply wiring intake 6 Control wiring intake

Note: In some circumstances, with certain machine types, it may not be possible to attach the supplied piping.

7 Drain connection

R36NUV1/Y1

Hole for anchor bolt 4-M12


30 350 (345~355) 48 140 30 620 900 96 140 41 61 30 320

4 2 1 3 7
1170

6 5 5
410 435 60

7 7 6
54 84 55 223 148 52 13 67 19 80 145

6 5

95

157.5

24

89

89 142

8
70 102 117

71

16

54

19

16

54

95

5
45 376 191

1 2 3 4 5 6 7 8

Gas pipe connection Liquid pipe connection Service port(in the unit) Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection

58

18

DIMENSIONS
OUTDOOR UNIT R42NUY1, R48NUY1, R51NUY1
Hole for anchor bolt 4-M12 350 (345~355)

(Unit: mm)

A R42NUY1 1170 1345

B 54 55

C 113

D 579

30

R48NUY1/51NUY1

140 30

620 900

96 140

30

41

48 61 320

4 2 1 3 7 6 5 5
410 435 60 55 95 95

7 6
B 223 84 19 80 145

7 6 5
95 53 52 13 67

24

89

54

C D

89 19 142 71 16 16

8
70 102 117

54

1 Gas pipe connection 2 Liquid pipe connection 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake 7 Control wiring intake 8 Drain pipe connection

45

376

191

R56NUY1

84 38

396

146 30

584 880

150

1345

30

35

370

30

Hole for anchor bolt 4-M12

58

4 3 2 1 7 6 5 7 6
538 568

5
95 60

60

95

49

name plate

90 14 137 40 61 11 102 11

14 67 115

84

144 14

90

24

84

49

275

1 Gas pipe connection 2 Liquid pipe connection

5
391

3 Service port(in the unit) 4 Grounding terminal M5(in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake 7 Control wiring intake 8 Drain outlet

19

REMOTE CONTROLLER

BRC7C613W

Wireless type

Remote controller dimensions


CEILING MOUNTED CASSETTE TYPE

Transmitting part

Remote controller holder installation procedure <Installation to wall surface>

Receiver installation procedure


Receiver

Receiver detail

Drain piping side

157

Liquid crystal remote controller (Wireless) Remote controller holder

Refrigerant piping side Decoration panel


CEILING SUSPENDED TYPE

62

17.5

BRC7NU66
Transmitting part
Remote controller holder installation procedure <Installation to wall surface>

Receiver installation procedure

The Front

Receiver

Receiver detail

Remote controller (Wireless)

115.5

Remote controller holder

54

18.1
2-5x9 Slot

Receiver detail
Service space for ceiling installation
(Ceiling opening)
More than 90 (Srevice space)

72 83.5 106

120

70

18 0.535
Switch box

(Ceiling opening)

49

Note : install more than 3 receivers in Do not the vicinity of one another. With 4 or more units, there is always the possibility of malfunction

(field Supplied parts)

BRC1C61
120

Wired type

Remote controller dimensions

KRC47-2A/ KRC47-4A
42 25 84 19 110 18 58

120

17

Remote controller installation procedure


A EXposed body, exposed cord
Staple
17

18 23 28 46

38 Cord outlet hole

92 61

14

B Exposed body, embedded cord

Conduit

C Exposed body, embedded code

0~5 17

117

CONTROL BOX

( Distance between remote controller and control box )

17

Through hole
(12~16)

KRC47-1A
136 124 81 32

Note) 1. Remote controller cord and staple are not attached. they are field supplied parts.

BRC1NU61

* Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more) 44.5


A

Specifications of cord Vinyl cord with sheath or cable Type (Insulated thickness: 1 mm or more) Size 0.75~1.25 mm2 Total length 500 m

20 25
B B

22 25 13

77

25 20

A A

111

24

41

38 41.5

17 R2

119

Note) The dimension of hole. a Hole type a (mm) A 6 B 10

36

85

10

20

[Space required for outdoor unit installation] (Unit: mm)


Dimensions inside brackets [ ] indicate case where air direction adjustment guide is adjusted downward.

For R26NU-56NU

The values represent the case for the R26 type through R56 type. The dimensions in ( ) are for the R36 and R56 type (The unit values is mm. ) In case of R56 model, the values in < > are those when the air discharge direction of the grille is downward.

When there is an obstruction on the inlet side When the overhead space is open
1. For single unit installation When there is an obstruction only on the inlet side
re

When there is an obstruction on the outlet side When the overhead space is open
1. For single unit installation

2. For series installation (more than two units)


0 0(1 0) or mo

500

or m

ore

When there are obstructions on both sides


100 or m

100

0o

rm

ore

ore

100

1. For single unit installation 2. For series installation (more than two units) When there are obstructions on both sides
An obstruction in the overhead space
ore
ss

2. For series installation (more than two units)

500

or m

500

or le

1000 or more
100 0o

or m

ore

0 10

or

mo

re

When there is an obstruction in the overhead space

500

or le

ss

100

0o

rm

ore 200

or m

ore

20

0 0(3

0)

or

mo

re

An obstruction in the overhead space

rm

ore

When there is an obstruction in the overhead space


1. For single unit installation When there is an obstruction on the inlet side
An obstruction in the overhead space
1000 or more
500 or le ss

When there are obstructions on both the inlet and outlet sides
Pattern 1
For other patterns, please refer to engineering databook.

When the obstruction on the outlet side is higher than the unit itself (There is no limit to the height of the obstruction on the outlet side.)

1000 or more

When there are obstructions on the inlet side and ss or le both lateral sides 500
An obstruction in the overhead space
150 or

100

or m

ore

When the overhead space is open


1. For single unit installation

mo

L
re 150 or mo re

150

or m

ore

ore or m 500 1000> <

) 100 50( more or

2. For series installation (more than two units) When there are obstructions on the inlet side and both lateral sides
500 or le

2. For series installation (more than two units)

An obstruction in the overhead space


100 0o rm

1000 or more

ss

ore 200

ore rm 0o > 100 1500 <

0) (30 200 more or

or

mo

re

(3 00

00

)o

rm

ore

21

1000 or more

MEMO

22

Warning

Daikin Industries, Ltd.s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES. Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM

All of the Daikin Groups business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.

JMI-0107

JQA-1452

Dealer

Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/
c All rights reserved Printed in Japan 05/09 HP SS

Specifications, designs and other content appearing in this brochure are current as of May 2009 but subject to change without notice.