Vacuum Circuit Breakers Vacuum Interrupter

Vacuum Circuit Breaker & Vacuum Interrupter

LSIS Pro-MEC VCB is user-friendly to give more convenience and safety by providing high speed interrupting time (3cycles), adopting the rapid auto-reclosing method, and having wide range of accessories.

7.2kV Draw-out (F class)

24kV Draw-out (F class)

Pro-MEC

VCB/VI
H1-4 H1-8 H1-9 H1-10 H1-19 H1-24 H1-27 H1-35 H1-40

Vacuum Circuit Breaker


Ratings Constructional and operating characteristics Control circuit diagram 7.2kV dimension 12kV dimension 17.5kV dimension 24kV dimension Accessories Types and ordering information

Contents

H1

Vacuum Interrupter
Features & Ordering information VI internal structure Basic functions and interrupting action VI endurance by interrupting current Dimensions Technical data H1-43 H1-44 H1-45 H1-46 H1-48 H1-50

Vacuum Circuit Breaker


LSIS Pro-MEC VCB is user-friendly to give more convenience and safety by providing high speed interrupting time (3cycles), adopting the rapid auto-reclosing method, and having wide range of accessories.

7.2kV Draw-out (F class) 24kV Draw-out (F class)

Wide range of accessories (optional)


Key Lock Padlock of earthing switch Button padlock Position switch of the earthing switch Button cover Locking coil of earthing switch Position switch (Cell switch) Shutter padlock Preparatory trip coil (Secondary trip coil) MOC (Mechanically operated cell switch)
H1-2

Latch checking switch TOC (Truck operated cell switch) Charge indicator Code plate (Miss insertion prevention) Position padlock Capacitor trip device Earthing switch Note 1) Rectifier
Note 1) The earthing switch is not available for 17.5kV VCB.

VACUUM CIRCUIT BREAKER

[ Compasion table for VCB (Short circuit test) ]

Compasion table for VCB (Short circuit test)

High reliability of the operating mechanism


- Separate design of the main circuit from the operating mechanism. - Adopt the toggle link method. - Improved the reliability of electric circuit. - Adopt the rapid auto-reclosing method as a standard option. (O-0.3sec.-CO-3min.-CO)

High interrupting performance


Make short of the interrupting time. (3cycles) Increase the rated short-circuit withstand characteristics. (1sec. to 3sec.)

Great operational safety


Reinforce the insulation in the conduct, by adopting the molded housing in each phase. Built in the device making the contacts open first when draw in and out. Adopt the tulip-shape connection between the cradle and the VCB.

H1-3

Vacuum Circuit Breaker


Ratings
Type Rated voltage Rated normal current Rated frequency Rated short-circuit breaking current Rated short-circuit breaking capacity Rated short-time withstand current Rated short-circuit making current Rated breaking time Rated opening time No-load closing time Withstand Power frequency voltage Impulse Rated operating sequence Type test Mechanical Electrical Capacitive current switching Note 1) Mechanical Lifetime Electrical Auxiliary switch Fixed E-type Installing method Draw-out type F-type G-type Note 2) M-type E-type VCB Weight
Note 3)

LVB-06-32D (kV) (A) (Hz) (kA) (MVA) (kA/3sec) (kAp) (Cycle) (sec) (sec) (kV/min) (kV/1.250) 1250 7.2 2000 50/60 31.5 390 31.5 82 3 0.04 0.06 20 60 O-0.3s-CO-3min-CO M2 (10,000 times) E2 (List1) C2 20000 30000 20000 30000 4a4b, 10a10b Visible, Fixed Visible, Tulip Visible, Tulip T (kg) (kg) (kg) (kg) (kg) (kg) Visible, Tulip Enclosed, Tulip Enclosed, Tulip 131.5 132.5 132.5(159) 52 60 54.5 62.5 62.5(110) 135(117) 155 IEC 62271-100 134.5 135.5 135.5(160) 210 211 220 131 135 Visible, Fixed Visible, Clip Visible, Tulip Visible, Tulip 3150 1250

LVB-06-40D 7.2 2000 50/60 40 500 40 104 3 0.04 0.06 20 60 O-0.3s-CO-3min-CO M2 (10,000 times) E2 (List1) C2 20000 30000 20000 30000 4a4b, 10a10b Visible, Fixed Visible, Tulip Visible, Tulip Visible, Tulip Enclosed, Tulip Enclosed, Tulip 135 136 136(162.5) 52 54.5 62.5(110) 138 139 139(163.5) 60 62.5 135(117) IEC 62271-100 Visible, Fixed Visible, Tulip Visible, Tulip Visible, Tulip 210 211 220 131 135 155 3150

Without maintenance (Time) Maintenance Maintenance (Time) (Time) Without maintenance (Time)

F-type G, M-type E-type

Cradle Applied standard Test laboratory

F-type G-type KERI Note 4)

Note 1) Applied cable-charging current switching test 2) In the event of ordering Enclosed Tulip type for G class VCB, please add T in the end of type name. (Ex: LVB-06G-20D/06-1A2B-T) 3) ( )* indicates the weight of Enclosed Tulip installing method VCB. 4) KERI: Korea Electrotechnology Research Institute

Enclosed VCB (Draw-out type, G-type)

G-type Cradle (Enclosed, Tulip contact)

Visible, Clip contact

Visible, Tulip contact

Enclosed, Tulip contact

H1-4

Type Rated voltage Rated normal current Rated frequency Rated short-circuit breaking current Rated short-circuit breaking capacity Rated short-time withstand current Rated short-circuit making current Rated breaking time Rated opening time No-load closing time Withstand Power frequency voltage Impulse Rated operating sequence Type test Mechanical Electrical Capacitive current switching Note) Mechanical Lifetime Electrical Auxiliary switch Fixed Installing Method E-TYPE Draw-out type F-TYPE G-TYPE M-TYPE E-TYPE VCB Weight Cradle Applied standard Test laboratory
Note) Applied cable-charging current switching test

LVB-12-32D/12, 20-T, 30 (kV) (A) (Hz) (kA) (MVA) (kA/3sec) (kAp) (Cycle) (sec) (sec) (kV/min) (kV/1.250) 1250 12 2000 31.5 650 31.5 81.9 3 0.04 0.06 28 75 O-0.3s-CO-3min-CO M2 (10,000 times) E2 (List 1) C2 20,000 30,000 20,000 30,000 4a4b, 10a10b Enclosed, Tulip Enclosed, Tulip (kg) (kg) (kg) (kg) (kg) (kg) 159 110 160 117 220 155 Visible, Tulip (Time) (Time) 3150

LVB-12-40D/12, 20, 30 12 1250 2000 40 831 40 104 3 0.04 0.06 28 75 O-0.3s-CO-3min-CO M2 (10,000 times) E2 (List 1) C2 20,000 30,000 20,000 30,000 4a4b, 10a10b Enclosed, Tulip 162 110 163 117 IEC 62271-100 220 155 Visible, Tulip 3150

LVB-17-40D/12, 20, 30 17.5 1250 2000 60 40 1200 40 104 3 0.04 0.06 38 95 O-0.3s-CO-3min-CO M2 (10,000 times) E2 (List 1) C2 20,000 30,000 20,000 30,000 4a4b, 10a10b Visible, Tulip 200 175 205 175 KEMA, PT & T 260 200 3150

60(E1,E2,C2: PT & T)

50(E1,C2:KEMA), 60(M2,E2,C2: PT & T)

Without maintenance (Time) Maintenance Maintenance Without maintenance (Time)

F-TYPE G, M-TYPE E-TYPE F-TYPE G, M-TYPE

PT & T: E1, E2, C2, M2

H1-5

Vacuum Circuit Breaker


Ratings
Type Rated voltage Rated normal current (kV) (A) LVB-20-13D LVB-20-13D/T LVB-20-16D LVB-20-16D/T LVB-20-25D LVB-20-25D/T 24 630 1250 Rated frequency Rated short-circuit breaking current Rated short-circuit breaking capacity Rated short-time withstand current Rated short-circuit making current Rated breaking time Rated opening time No-load closing time Withstand Power frequency voltage Impulse Rated operating sequence Type test Mechanical Electrical Capacitive current switching Note 1) Mechanical Lifetime Electrical Auxiliary switch Fixed Installing method E-type Draw-out type F-type G-type Note 2) M-type E-type VCB Weight Cradle Applied standard Test laboratory KERI KEMA F-type G, M-type E-type F-type G-type (kg) (kg) (kg) (kg) (kg) (kg) Without maintenance (Time) Maintenance Maintenance (Time) (Time) Without maintenance (Time) (Hz) (kA) (MVA) (kA/3sec) (kAp) (Cycle) (sec) (sec) (kV/min) (kV/1.250) 50/60 12.5 520 12.5 32.5 3 0.04 0.06 50 125 O-0.3s-CO-3min-CO M2(10,000 times) E2 (List1) C2 20000 30000 20000 30000 4a4b, 10a10b Visible, Fixed Visible, Clip Visible, Clip Visible, Tulip 145 145 155 80 82 110 IEC 62271-100 Enclosed, Tulip Enclosed, Tulip Enclosed, Tulip Enclosed, Tulip 145 145 187 80 82 120 24 630 1250 50/60 16 665 16 40 3 0.04 0.06 50 125 O-0.3s-CO-3min-CO M2(10,000 times) E2 (List1) C2 20000 30000 20000 30000 4a4b, 10a10b Visible, Fixed Visible, Clip Visible, Clip Visible, Tulip 145 145 155 80 82 110 IEC 62271-100 Enclosed, Tulip Enclosed, Tulip Enclosed, Tulip Enclosed, Tulip 145 145 187 80 82 120 24 630 1250 2000 50/60 25 1000 25 65 3 0.04 0.06 50 125 O-0.3s-CO-3min-CO M2(10,000 times) E2 (List1) C2 20000 30000 20000 30000 4a4b, 10a10b Visible, Fixed Visible, Clip Visible, Clip Visible, Tulip 145 145 155 80 82 110 IEC 62271-100 Enclosed, Tulip Enclosed, Tulip Enclosed, Tulip Enclosed, Tulip 145 145 187/218 (2000A) 80 82 120

Note 1) Applied cable-charging breaking current 2) In the event of ordering Enclosed Tulip type for G class VCB, please add T in the end of type name. (Ex: LVB-06G-20D/06-1A2B-T)

Fixed type VCB

E-type cradle

F-type cradle

G-type cradle (Withdrawable by lever)

G-type cradle (Withdrawable by screw)

H1-6

Motor
When the closing spring is charged, the control power of motor is turned off by the built-in limit s/w.
Rated voltage DC 48V DC 110V DC 125V DC 220V
Note 1) Range of the normal operating voltage: 85~110% 2) DC 24V is the underdeveloped rating.

The peak value of the inrush current (A) 21 20 20 17

Rated current (A) 4 3 3 2.6

Consumption power (W) 350 330 330 374

Charging time (Sec.) 13 12 12 12

Closing Coil (C)


The coil operated only when the power is applied continuously over 45ms. It has built-in electrically anti-pumping circuit.
Rated voltage DC 48V DC 110V DC 125V DC 220V
Note 1) Range of the normal operating voltage: 85~110% 2) DC 24V is the underdeveloped rating.

Shunt coil (TC)


When the VCB is 'ON' position, even though the control power of a shunt coil is 'OFF', the VCB maintains the 'ON' position.
Rated voltage DC 48V DC 110V DC 125V DC 220V
Note 1) Range of the normal operating voltage: 70~110% 2) DC 24V is the underdeveloped rating.

Rated current (A) 6 3 3 2.5

Rated current (A) 6 3 3 2.5

Auxiliary switch
Standard 4a4b / Optional 10a10b
Classification AC Contact Ratings DC 125V 30V 10 250V 10 125V 10 250V 10 10 General load (A) Inductive load (A) 5 5 5 5 5 4a4b 10a10b Contact configuration

Position of the Aux.contact switch


VCB ON OFF a contact ON OFF bcontact OFF ON

Note) The contact capacity of the following accessories are the same with that of the Aux. switch. Position switch, Closing sp ring contact, Charging complete indicating contact, Position switch of the earthing switch, Mechanically operated cell switch, Truck operated cell switch.

Charge indicator of the closing spring


Indicating the condition of the closing spring.

Position indicator of the main contacts


Indicating the 'Close' or the 'Open' of the main contacts. Close position: ON Open position: OFF

Charged

Discharged Close position Open position

Counter
Mechanically counts the switching of the VCB by 5digits analog type counter (Standard option) H1-7

Vacuum Circuit Breaker


Constructional and operating characteristics
Charge Indicator of the closing spring Close button Key lock (Optional) Trip button Manual charge hole Position indicator of the main contacts Counter Screw hole for draw-in and draw-out Nameplate Mounting hole Safety cover

Manual charge
Insert the charge handle into the manual charge hole in the front of a VCB, and rotate it to clockwise over 40times and the charge complete with a metal sound.

Motor charge
If you apply the control power to a VCB, the closing spring will be charged automatically by a motor and then the control power will be turned off by the built-in limit s/w. Please use the same control voltage for motor, Closing coil, Trip coil.

Sequence of the switching mechanism

H1-8

Control circuit diagram

Connecting terminal arrangement A Type B Type

: External terminal of VCB 52: Vacuum circuit breaker M: Spring charging motor TC: Trip coil TC1: Secondary Trip coil C: Closing coil Y: Anti-pump relay 52a: Auxiliary switch (NO)

52b: Auxiliary switch (NC) LS1: Closing interlock limit switch (only withdrawable type) LS2: Motor stopping, closing spring charged indication LS3: Anti-closing, anti-pumping limit switch LCS1: Opening latch checking switch(preventing closing unless the trip latch is properly reset) LS4, LS5: Position s/w (close in test position) LS6, LS7: Position s/w (close in run position)

Note 1) LCS1: Latch checking switch Optional accessories

2) Trip coil supervision (Trip coil monitoring contact)

3) Position switch: 4a (Terminal No.: 1, 2, 3, 4, 5, 6, 7, 8)

4) TC1: Secondary trip coil (Preparatory trip coil Terminal No.: 82,83)

H1-9

5) In fixed type VCB, LS1 (Closing-coil limit switch) is not available.

Above circuit diagram is based on OFF status of VCB. and closing spring is charged.

Vacuum Circuit Breaker


7.2kV dimension (VCB)
LVB-06P-32D, 40D (Visible, Fixed) - (1250/2000A)
Top <Terminal conductor>
(Unit: mm)

*125.5 applied to all 7.2kV VCB.

Front

Side

LVB-06P-32D, 40D (Visible, Fixed) - (3150A)


Front Side Top

H1-10

LVB-06E, F, G-32D, 40D E, F, G class - (1250/2000A)


Top <Terminal conductor>

(Unit: mm)

Front

Side

LVB-06G- 32D/T, 40D/T G class (Enclosed, Tulip contact) - (1250/2000A)


Front Side

H1-11

Vacuum Circuit Breaker


7.2kV dimension (VCB)
LVB-06E-32D, 40D
Front

E class (Visible, Tulip contact) - (3150A)


Side Top

(Unit: mm)

LVB-06F-32D, 40D
Front

F class (Visible, Tulip contact) - (3150A)


Side Top

H1-12

LVB-06G-32D, 40D
Front

G class (Visible, Tulip contact) - (3150A)


Side

(Unit: mm)

Top

H1-13

Vacuum Circuit Breaker


7.2kV dimension (Cradle)
LCL-06E-32D, 40D
Front

E class (Visible, Tulip contact)


Side
Rating A 1250A 10 2000A 20

(Unit: mm)

Top <Terminal conductor>

LCL-06E-32D, 40D
Front

E class (Visible, Tulip contact) - (3150A)


Side Top

H1-14

LCL-06F-32D, 40D
Front

F class (Visible, Tulip contact) - (1250/2000A)


Side
Rating A 1250A 10 2000A 20

(Unit: mm)

<Terminal conductor> Top

LCL-06F-32D, 40D
Front

F class (Visible, Tulip contact) - (3150A)


Side

Top

H1-15

Vacuum Circuit Breaker


7.2kV dimension (Cradle)
LCL-06G-32D, 40D G class(Visible, Tulip contact) - (31.5/40kA 1250/2000A)
Front Side
(Unit: mm)

Top
Rating A 1250A 2000A 10 20

<Terminal conductor>

H1-16

LCL-06G-20D/T, 25D/T, 32D/T, 40D/T G class (Enclosed, Tulip contact) - (630/1250/2000A)


Front Side

(Unit: mm)

Top

<Terminal conductor>

Rating A B

31.5/40kA 1250A 2000A 12 48 25

H1-17

Vacuum Circuit Breaker


7.2kV dimension (Cradle)
LCL-06G-32D, 40D
Side

G class (Visible, Tulip contact) - (3150A)

(Unit: mm)

Top

<Terminal conductor>

<User busbar reguirement>


*To connect with VCB bushing terminals s user busbar should have below dimensions and two holes.

H1-18

12kV dimension (VCB)


LVB-12G-32D/T
Front

G class (Enclosed, Tulip contact) - (1250/2000A)


Side

(Unit: mm)

LVB-12G-40D
Front
470

G class (Enclosed, Tulip contact) - (1250/2000A)


Side
325 330

Top
150 150

726.5

295

549

438

40kA 1250/2000A

G class

10

496

288

33.5

355

69

H1-19

668

Vacuum Circuit Breaker


12kV dimension (VCB)
LVB-12G-40D
Front
620

G class (Enclosed, Tulip contact) - (3150A)


Side
325 336

(Unit: mm)

806.6

747

502

Top
210 210

40kA 3150A

676

G class

H1-20

10

714

290

348.5

360

12kV dimension (Cradle)


LCL-12G-25D/T, 32D/T
Front

G class (Enclosed, Tulip contact) - (630/1250/2000A)


Side

(Unit: mm)

Top

<Terminal conductor>

Rating A B

25kA 1250A 2000A 12 48 25

H1-21

Vacuum Circuit Breaker


12kV dimension (Cradle)
LCL-12G-40D
Front

G class (Enclosed, Tulip contact) - (1250/2000A)


Side

(Unit: mm)

1250A:12t 2000A:25t

295 731.5 946

40kA 1250/2000A

G class

Top

<Terminal conductor>
150 150 60 26 83 RUN 26

600

560

4-14 Mount hole

100

662

H1-22

150

150

630

1235

LCL-12G-32D/LCL-12G-40D
Front

G class (Enclosed, Tulip contact) - (3150A)


Side
12 12

(Unit: mm)

360 764 1014

40kA 3150A

G class

Top

<Terminal conductor>
230 230 120 70 35

439 800 760 4-14 Mount hole 100 724 210 210 145

H1-23

1100

Vacuum Circuit Breaker


17.5kV dimension (Cradle)
LVB-17G-40D
Front

G class (Visible, Tulip contact) - (1250/2000A)


Side Top

(Unit: mm)

LVB-17G-40D
Front

G class (Visible, Tulip contact) - (3150A)


Side Top

H1-24

H1-24

LCL-17G-40D
Side

G class (Visible, Tulip contact) - (1250/2000A)

(Unit: mm)

Top

<Terminal conductor>

H1-25

Vacuum Circuit Breaker


17kV dimension (VCB)
LCL-17G-40D
Side

G class (Visible, Tulip contact) - (3150A)

(Unit: mm)

Top <Terminal conductor>

H1-26

24kV dimension (VCB)


LVB-20P-13D, 16D, 25D (Visible, Fixed) - (630/1250/2000A)
Front Side
(Unit: mm)

<Terminal conductor>

LVB-20E, F-13D/(T), 16D/(T), 25D/(T)


Front

E, F class - (630/1250/2000A)
<Enclosed, Tulip contact>

Side <Visible, Clip contact>

Note ) In case of 12.5kA & 16kA 630A, the dimension shown in parenthesis should be applied.

H1-27

Vacuum Circuit Breaker


24kV dimension (VCB)
LVB-20G-13D, 16D, 25D
Front

G class (Visible, Tulip contact) - (630/1250A)


Side

(Unit: mm)

LVB-20G-13D/T, 16D/T, 25D/T


Front

G class (Enclosed, Tulip contact) - (630/1250/2000A)


Side

Note 1) (

): The dimension shown in parenthesis should be applied to LVB-20G-13E/T or LVB-20G-16E/T, LVB-20G-25E/T for 630A and 1250A in case that distance between phase & phase is 210mm. 2) IP Cover applied both sides in case of 265mm phase distance.

H1-28

H1-28

24kV dimension (Cradle)


LCL-20E-13D, 16D, 25D
Front

E class (Visible, Clip contact) - (630/1250/2000A)


Side
Rating 630, 1250A 2000A A B T 768 190.5 10 778 185.5 20

(Unit: mm)

Top

<Terminal conductor>

Note) Insulation barrirer is not used for rating 12.5kA 630A and 16kA 630A

H1-29

Vacuum Circuit Breaker


24kV dimension (Cradle)
LCL-20E-13D/T, 16D/T, 25D/T
Front

E class (Enclosed, Tulip contact) - (630/1250/2000A)


Side
Rating 630, 1250A 2000A A B T 768 190.5 10 778 185.5 20
10(630/1250A) 20(2000A) 404.5
947.5 1120 1167 97.5 6.5

(Unit: mm)

730 960 972

280

115

Top
630A
20 40 67

<Terminal conductor>
1250A
90 47

2000A
42 100 45

660 ST: 260

25

40.5

265

820

145

2-14

4-14

4-14

40 80

210.5

265

40

40

20

40

20

40

245

202

40 80

20

7-14

110

400

400

210

Note) Insulation barrirer is not used for rating 12.5kA 630A and 16kA 630A

H1-30

100

40

90

300

300

340 1033

265

265

15

LCL-20F-13D, 16D, 25D


Front

F class (Visible, Clip contact) - (630/1250/2000A)


Side
Rating 630, 1250A 2000A A B T 768 190.5 10 778 185.5 20

(Unit: mm)

<Terminal conductor> Top

Note) Insulation barrirer is not used for rating 12.5kA 630A and 16kA 630A

H1-31

Vacuum Circuit Breaker


24kV dimension (Cradle)
LCL-20F-13D/T, 16D/T, 25D/T F class(Enclosed, Tulip contact) - (630/1250/2000A)
Front Side
Rating 630, 1250A 2000A A B T 10 20 768 190.5 778 185.5
(Unit: mm)

<Terminal conductor> Top

Note) Insulation barrirer is not used for rating 12.5kA 630A and 16kA 630A

H1-32

LCL-20G-13D, 16D, 25D


Front

G class (Visible, Tulip contact) - (630/1250A)


Side

(Unit: mm)

Top

<Terminal conductor>

H1-33

Vacuum Circuit Breaker


24kV dimension (Cradle)
LCL-20G-13D/T, 16D/T, 25D/T G class (Enclosed, Tulip contact) - (630/1250/2000A)
Front Side
(Unit: mm)

Top

<Terminal conductor>

210mm
Note) ( ): The dimension shown in parenthesis should be applied to LVB-20G-13E/T or LVB-20G-16E/T, LVB-20G-25E/T for 630A and 1250A in case that distance between phase & phase is 210mm.

Earthing Switch

H1-34

Accessories
Accessories for VCB
Key lock
When it is locked by a key, the closing operation is not available (electrically and mechanically) without a Key.

Button padlock
Button padlock protects 'ON' or 'OFF' button when accident is occurred by operation at discretion. It is available to operate after release button padlock.

Button cover
Button cover protects 'ON' of 'OFF' button when accident is occurred by operation at discretion. It is available to operate by push bar.

<Push bar>

Position switch (Cell switch)


Indicating the position (Run or Test) of a VCB, by mechanically pressing the switch when a VCB change the position. - RUN: 2a - TEST: 2a

<G class>

Note) In case that position of VCB changed to Run or Test position, a contact will be closed.

H1-35

Vacuum Circuit Breaker


Accessories
Accessories for VCB
Secondary coil (Preparatory trip coil)
The main coil and the preparatory coil is connected in parallel. So even though there happens a fault in the trip coil, the VCB can be tripped by one of the two trip coils.

Latch checking switch


When the Latch is in abnormal position, the Latch checking switch prevents the closing operation even though there is the 'Closing' signal.

Charge indicator
Remotely indicates the charging is completed. (Standard Feature) - Terminal No.: 9, 10

Position padlock
The hole to prevent the draw-in and out of a VCB from the present position.('Run' or 'Test') Standard option in the interlock lever of the E, F class draw-out type VCB. (Hole size = 8)

H1-36

Accessories for Cradle


Earthing switch (for G class draw-out type only)
For the safety during the maintenance of a VCB panel, discharge the charging current in the load side of a VCB with this earthing switch.

Padlock of earthing switch (for G class draw-out type only)


The hole to prevent the accident through carelessness earthing switch operation, the locking of the earthing switch is available when the switch is in 'OFF' position. (Hole size = 8)

Position switch of the earthing switch (for G class draw-out type only)
Indicates the 'ON' or 'OFF' status of the earthing switch. (5a5b)

Locking coil of earthing switch (for G class draw-out type only)


To prevent the accident through carelessness earthing switch operation, the earthing switch can be changed to 'ON' position after releasing the lock by magnetizing the coils.

<Earthing Switch Position Switch>

<Earthing Switch Locking Coil>

H1-37

Vacuum Circuit Breaker


Accessories
Accessories for Cradle
Shutter padlock
The hole to lock the shutters (load and line side) in close position, to increase the safety during the maintenance of a VCB draw-out position. (Hole size = 8)

Mechanically operated cell switch (MOC) -for G class draw-out type only
The auxiliary switch (3a4b), which Indicate the 'ON' or 'OFF' condition of a VCB, but operated only when the VCB is in 'Run' state. (Installed in the bottom of a cradle)

Note) #11, 21 are Early b contact

Truck operated cell switch (TOC) -for G class draw-out type only
The auxiliary switch (3a4b), which indicate the 'Run' state of a VCB and is operated by the movement of a VCB frame. (Installed in the bottom of a cradle)

Note) #11, 21 are Early b contact

Code plate (Miss insertion prevention) -for E, F class draw-out type only
To prevent the insert a VCB to a cradle, when the ratings of VCB and cradle are different.

Padlock
To prevent the insert draw-in/out handle to a screw hole by operating G class VCB temporarily

H1-38

Optional accessories
Capacitor trip device (CTD)
When the control power is off, the CTD supply the power for tripping a VCB.

Dimension

Ratings Type CB-T1 Rated input voltage Freguency (Hz) Charging volt(V) Charging time Tripping time Allowable Input voltage range Capacitor rating( F)

Specification CB-T2 AC100/110V 50/60 140/155 AC200/220V 50/60 280/310

Connection diagram

CDT

Within 10 Sec. after the AC power off Within 30 Sec. after the AC power off 85% ~ 100% 1000 85% ~ 110% 560

Rectifier
When the DC power is not available, rectify the AC power and get the DC power for closing coil.
Type VCB-X AC Input voltage Output current 1 100/110V 1 200/220V 40A DC Rating time

Dimension

150

10 sec.

100

80

40

Connection diagram

Standard tool
E, F class G class

Handle for draw-in and out


Handle for draw-in and out the VCB (Standard feature in the draw-out type)

Manual charging handle


Handle for charging the spring manually. (Standard feature)
H1-39

29.5

25

70 +

Vacuum Circuit Breaker


Types and ordering information
12kV
LVB
LS VCB

12

G
Installation method G M G class draw-out type G class draw-out type + Bushing

32

D
Revision No. D Pro-MEC

12

1A
Control voltage 1A 1B 1C 1E DC110V DC220V DC48V DC125V

2B

B, C1, D1

Rated voltage 12 12kV

Breaking current 32 40 31.5kA 40kA

Rated current 12 20 30 1250A 2000A 3150A

Auxiliary switch 2B 4a4b(A type connector) 2E 10a10b(A type connector) 2G 4a4b(B type connector) 2H 10a10b(B type connector) Accessories B Position Switch (RUN/TEST:2a2a) C1 Button Padlock (ON) C2 Button Padlock (OFF) C3 Button Padlock (ON/OFF) D1 Button Cover (ON) D2 Button Cover (OFF) D3 Button Cover (ON/OFF) E Button padlock (ON)+ Button cover (OFF) F Button padlock (OFF)+ Button cover (ON) G Key Lock H Secondary Trip Coil(Preparatory trip coil) J Fire-endurable wiring cable assy K Opening Latch Checking Switch S Pad Lock (G class) T Enclosed type, Tulip contact

Cradle
LCL
LS Cradle

12

G
Installation method G G class draw-out type

32
Breaking current 32 40 31.5kA 40kA

D
Revision No. D Pro-MEC

12
Rated current 12 20 30 1250A 2000A 3000A

A, B, C
Accessories T Enclosed type, Tulip contact

Rated voltage 12 12kV

H1-40

17.5kV
LVB
LS VCB

17

G
Installation method P E F Fixed type E class draw-out type F class draw-out type G class draw-out type

40

D
Revision No. D Pro-MEC

12

1A
Control voltage 1A 1B 1C 1E DC110V DC220V DC48V DC125V

2B

B, C1, D1

Rated voltage 17 17.5kV

Breaking current 40 40kA

Rated current 12 20 30 1250A 2000A 3150A

Auxiliary switch 2B 4a4b(A type connector) 2E 10a10b(A type connector) 2G 4a4b(B type connector) 2H 10a10b(B type connector) Accessories B Position Switch (RUN/TEST:2a2a) C1 Button Padlock (ON) C2 Button Padlock (OFF) C3 Button Padlock (ON/OFF) D1 Button Cover (ON) D2 Button Cover (OFF) D3 Button Cover (ON/OFF) E Button padlock (ON) + Button cover (OFF) F Button padlock (OFF) + Button cover (ON) G Key Lock H Secondary Trip Coil(Preparatory trip coil) K Opening Latch Checking Switch S Pad Lock (G class) J Fire-endurable wiring cable assy

Cradle
LCL
LS Cradle

17

40
Breaking current

D
Revision No. D Pro-MEC

12
Rated current 12 20 30 1250A 2000A 3150A A

A, B, C
Accessories MOC (3a4b) + TOC (3a4b)
Note) A is for G class only

Installation method E F G E class draw-out type F class draw-out type G class draw-out type

Rated voltage 17 17.5kV

H1-41

Vacuum Circuit Breaker


Types and ordering information
24kV
LVB
LS VCB P E Rated voltage 20 24kV F G M

20

G
Installation method Fixed type E class draw-out type F class draw-out type G class draw-out type G class draw-out type + Bushing

13

D
Revision No. D Pro-MEC
Note1)

06

1A
Control voltage 00 1A 1B 1C 1E 1F 1H 1T DC110V DC220V DC48V DC125V AC220(M), DC110(TC) AC220(M), DC220(TC) AC110(M), DC110(TC) Auxiliary switch

2B

B, C, D
Accessories B C1 C2 C3 D1 D2 D3 E F G H Position Switch (RUN/TEST:2a2a) Button Padlock (ON) Button Padlock (OFF) Button Padlock (ON/OFF) Button Cover (ON) Button Cover (OFF) Button Cover (ON/OFF) Button padlock (ON) + Button cover (OFF) Button padlock (OFF) + Button cover (ON) Key Lock Secondary Trip Coil (Preparatory trip coil) Fire-endurable wiring cable assy Opening Latch Checking Switch Dummy VCB(AMP Jack) Dummy VCB(Phoenix Jack) Earthing Truck(Lower terminal earthing) Earthing Truck(Upper terminal earthing) Pad Lock (G class) Enclosed type, Tulip contact Option

Pro-MEC (Minimized type)

Breaking current 13 16 25 12.5kA 16kA 25kA

Rated current 06 12 20 630A 1250A 2000A


Note2)

00

2B 4a4b(A type connector) 2E 10a10b(A type connector) 2G 4a4b(B type connector) 2H 10a10b(B type connector)

J K P1 P2 Q R S T

Note) 1. Version E is available only at 24kV G class and its distance between phases is 210mm. 2. "00" is used for ordering Earthing Truck and Dummy VCB 4. Accessory only for versions D and E

N CTD(Capacitor Trip Device) O Rectifier

Cradle
LCL
LS Cradle E F Rated voltage 20 24kV

20

G
Installation method E class draw-out type F class draw-out type

13
Breaking current 13 16 25 12.5kA 16kA 25kA
Note1)

D
Revision No. A Conventional D E Pro-MEC Pro-MEC (Minimized type)

06
Rated current 06 12 20 630A 1250A 2000A
Note2) Note2)

A, B, C
Accessories A MOS(3a4b)+ TOC(3a4b) B Earthing Switch C T PS Earthing Switch Position Switch+ Earthing Switch Locking coil Enclosed type, Tulip contact Position S/W Block (24kV E/F class only)

G G class draw-out type

Note2)

Note) 1. Version E is available only at 24kV G class and its distance between phases is 210mm. 2. Versions A, B and C are available only at G class VCB.

H1-42

Vacuum Interrupter
Features & Ordering information
Features
Accumulation of more than 20 years of vacuum-related technologies Simplified arc extinguishing system Spiral contact structure with Radial magnetic field provides effective dispersing of the acr energy. Simple structure and high quality Sealing after complete removal of gas in the vacuum chamber in order to secure a long vacuum confidentiality Small size and light weight The new contact material used to enhance the competitiveness of the size Wide rated coverages Wide interrupting range from 6kV up to 40.5kV 40kA High reliability and electrical life Certification by KERI and KEMA according to the latest standard IEC62271-100 (2008) E2, LIST3, M2

Modeling system
LV7

Basic type L V 7 LS Vacuum Series No.

Revision No A, B
Null P C E G

ETC. Straight type Potting type Wave type Embedded type Gas Insulation type

H1-43

Vacuum Interrupter
VI internal structure
Largely movable and fixed electrodes and main shield compose the Susol VI. The main components are shown in the following.

Fixed electrode

Fixed seal cup

Fixed shield

Contacts

Arc shield

Bellows shield

Ceramic

Bellows

Movable seal cup

The vacuum rate within the VI is very high(approximately 5x10-5 Torr) and the spacing between fixed contact and movable contact is about 6 ~ 20mm, depending on the voltage. The contacts are in a structure that arc can easily be extinguished and the surfaces of the contacts are made of special alloy (copper - chromium) and the interior is completely sealed to prevent loss of vacuum. Therefore the wearing of the contacts can be minimized in the event of short-circuit and the arc energy by overvoltage or switching can be reduced effectively.

H1-44

Basic functions and interrupting action


Interrupting action by VI

In case of using the flat contact any of the designs do not reflect on when contacts are opening the arc with high temperature is contracted and fixed in the center of the contacts, Which is called pinch effect. To prevent the effect two kinds of contact shapes are designed. One is Axial magnetic field which spreads the arc before its contraction, and the other is Radial magnetic field which permits the contraction of the arc but makes it rotated to disperse the energy. Because contracted arc is shaped like a cylinder it is called Contracted arc or columnar arc.
Arc voltage waveforms and arc image captured during arcing time

Spiral contact structure (Radial magnetic field ), using the force (F = j B) generated by the interaction of the radial magnetic field caused by the current flowing through the arc between two contacts, disperse the arc energy evenly on the surface of contact by rotating the arc that is contracted by the pinch effect so as to minimize contact damage. The images show arc behavior during the arcing time of about 8ms by shooting with high-speed camera capable of shooting 10,000 frames per sec. (0.1ms/frame) by focusing on parts of the arcing time on the above graph and simultaneously measured arc voltage also represented to show arc state by section

Radial magnetic field type contact

Columnar arc Current

Direction of rotating arc

Arc driving principle in the contacts of Radial magnetic field

H1-45

Vacuum Interrupter
VI endurance by interrupting current

Number[ops.]

Interrupting current [kA]

Number[ops.]

Interrupting current [kA]

VI model LV2 at 7.2kV


N : Operation numbers I : Interrupting current N : Operation numbers I : Interrupting current

VI model LV3 at 7.2kV

Number[ops.]

Interrupting current [kA]

Number[ops.]

Interrupting current [kA]

VI model LV4 at 24kV


N : Operation numbers I : Interrupting current N : Operation numbers I : Interrupting current

VI model LV5 at 17.5kV

H1-46

Number[ops.]

Interrupting current [kA]

Number[ops.]

Interrupting current [kA]

VI model LV8 at 17.5kV


N : Operation numbers I : Interrupting current N : Operation numbers I : Interrupting current

VI model LV7-P1 at 24kV

Number[ops.]

Interrupting current [kA]

VI model LV8 at 36kV


N : Operation numbers I : Interrupting current

Note) 1. Above graphs represent the characteristics of the electrical life of LS Susol VCB. 2. Life characteristics of each model in each rating represents the LOG-LOG graphs.

H1-47

Vacuum Interrupter
Dimensions
LV2 LV3 LV4

LV5-P

0 17-0.3

LV5A

0 21-0.3

LV8

5.2+0.1 0

0 -0.1

20 +0.5 0

30 +0.5 0

+0.1 0

+0.1 0

H1-48

30 +0.3 0

6 +0.1 0

0 17 -0.3

LV7-P1 / LV8-P

LV7-C

LV10404

6 +0.1 0

0 -0.1

0 -0.1

+0.1 0

30 +0.3 0

30 +0.5 0

0 9

H1-49

Vacuum Interrupter
Technical data
Type LV2 LV3 LV4-E LV5-P

Outer view

Rated voltage Rated power frequency withstand voltage Electrical ratings Rated impulse withstand voltage Rated frequency Rated normal current Rated short circuit current Rated short circuit making current Rated duration of short-circuit Interrupter weight Mechanical data Moving part weight Outline dimension (mm)

(kV) (kV, rms) (kV, crest) (Hz) (Amp) (Sym.) (kA) (kA, peak) (sec) (kg) (kg) a b c 8 20.8

7.2 7.2 20 20 60 60 50/60 50/60 400/630 630/1250 12.5 20 32.5 33 0.8 0.3 0.7 132 158 91 105 62 80 61 10 0 7~1.0 22 0 7~1.0 22 80 154 8.5 12.6 33 M2 M2 227 0 7~1.0 1 12 0 7~1.0 1.4 1.2 52 25 65 41.6

24/25.8 50 135 50/60 630 16 20 52 3

12/17.5 42 95 50/60 630/1250 25 65 3 2.4

0.5 208 159 62 1 1.3~1.5 2 0 7~1.0 2 120 9 3 M2 154

0.7 220 163 90 101 0.7~1.0 2 0.7~1.0 2 227 12.6 3 M2

Contact stroke Opening speed, average 0 to 75% of full stroke Mechanical requirements Overtravel during opening, Max. Closing speed, average last 33% of full stroke Contact bounce duration, Max. Added force from atmospheric pressure Contact force from atmospheric pressure Contact erosion limit Mechanical life

(mm) (m/s) (mm) (m/s) (sec) (kgf) (kgf) (mm) (10 4, Operations)

H1-50

LV5A

LV7-P1

LV7-C

LV8

LV8-P

LV10404

12/17.5 24/25.8 42 65 95 125 50/60 50/60 2000 20 52 34 3.0 1.0 220 272 160 80 101 12 0.7~1.0 22 0.7~1.0 0.7~1.0 22 154 227 12.6 25.5 33 M2 M2 227 306 367 227 216 145 1 1.0~1.3 7.3 2.2 25 65 2500 25 65 ~3150 31.5 40 81.9 104 25 65

40.5 17.5 95 38 185 95 50/60 50/60 ~3150 ~3150 31.5 81.9 44 9.8 6.6 2.6 2.2 390 272 329 210 145 135 17~19 12 1.3~1.5 1.0~1.3 22 0.7~1.0 0.7~1.0 22 306 25.1 25.8 33 M2 M2 367 460 227 1 17~19 40 104 50 130 25 65

36 70 170 50/60 ~3150 31.5 81.9 4 7.3 2.2 272 216 145 40 104

7.2/12 20/28 60/75 50/60 4000 40 104 4 8.7 2.0 317 210 135 101 17 50 130

25.8 70 150

3150 40 104 3

1.3~1.5 2 0.7~1.0 2 306 25 3 M2 367 367

1.0~1.3 1.5 0.7~1.0 2 406 25.8 3 M2 367

H1-51

Pro-MEC MCSG

VCB
H2-2 H2-4 H2-5

Vacuum Circuit Breaker for MCSG


Features and Structure Control circuit diagram Dimensions

Contents

H2

Vacuum Circuit Breaker for MCSG


Features and Structure
Features
Module type VCB Convenient especially for fabricating MCSG
- Housing is designed like VCB compartment style - MCSG panel can be easily constructed if combined with Low voltage compartment, Busbar compartment and Cable compartment.

Convenient for maintenance and offering high safely


- Earthing switch can be operated from outside of the panel, and which makes earthing of 3 phases at the same time. - Without opening the compartment panel door, breaker can be drawn in or out electrically or manually

Main functions
- Breaker : draw- in or out electrically or manually - Compartment : 3-positions

Standard
- IEC 62271-100

Name plate Manual closing button Keylock Manual trip button Manual charging hole Contact position indicator Closing spring charge indicator Operation counter Insertion & Draw-out screw Geared Mechanism

Electrical drive unit

Compartment

Earthing switch

Bushings

Shutter

H2-2

Ratings
Type Rated voltage (kV) Rated normal current (A) Rated frequency (Hz) Rated short-circuit breaking current (kA) Rated short-circuit breaking capacity (MVA) Rated short-time withstand current (kA) Rated short-circuit making current (kA) Rated breaking time (Cycles) Withstand Power frequency (kV) voltage Impulse (kV/1.250 ) TRV rising rate (kV/ ) TRV max. (kV) Rated operating sequence Mechanical lifetime Electrical lifetime Rated control voltage (V) Rated trip voltage( V) Standard auxiliary switch Rated opening time (s) No-load closing time (s) Rated charging motor current (A) Rated closing coil current (A) Rated trip coil current (A) Closing spring charging time (s) Draw-in/out motor voltage (V) Draw-in/out motor current (A) Distance between phases (mm) breaker Weight (kg) compartment Installing Applied standard LVB25-25/06 630 2000 25.8 60 25 1100 25/3s 65 3 50/1min 125 0.47 41 O-0.3s-CO-3min-CO 10,000operations 10,000operations DC 110V DC 110V 4a4b, 8a8b 0.04 0.06 7 5 5 12 DC 110V 5 265 G IEC 62271-100 LVB25-25/20

205 281 293

236.5

Breaker

LVB
LS VCB

25
G

G
Installation method Gclass draw-out

25

I
Version

06

1A
Control voltage 1A DC110V 1B DC220V 1C DC48V 1E DC125V

2B

B,C,D
Accessories

B Position Switch C1 Button Padlock(ON) C2 Button Padlock(OFF) C3 Button Padlock(ON/OFF) D1 Button Cover(ON) D2 Button Cover(OFF) D3 Button Cover(ON/OFF) E Button Padlock(ON)+Button Cover(OFF) F Button Padlock(OFF)+Button Cover(ON) G Key Lock H Secondary Trip Coil

Rated voltage 25 25.8kV Breaking current 25 25kA

Rated current 06 20 630A 2000A

1F AC220(M), DC110(TC) 1H AC220(M), DC220(TC) 1T AC110(M), DC110(TC) Auxiliary switch 2G 4a4b(B type connector) 2H 8a8b(B type connector)

Cradle(Compartment)

LCL
LS VCB 25

25
Rated voltage 25.8kV C

C
Installation method Bushing 25

13
Breaking current 25kA

D
Version 06 20

06
Rated current 630A 2000A

A,B,C
Accessories B Earthing Switch E Door

H2-3 3

MOTOR POWER SOURCE

CLOSING POWER SOURCE

4 34 35 52b 34 34

LS1

1 2

TC

Control circuit diagram

A2 A6
23 25 27 29 41 43 45 47 37 39 51 53 55 57 59 71

10

TRIP POWER SOURCE

H2-4
P
CW () Run 3 13 43 89X 44 1 LS6 LS5 1 89X 2 PS1 23 25 27 29 41 43 45 47 33 89Y 89X 33 37 39 51 53 55 57 59 71 2 4 PS2 22 24 26 28 40 42 44 46 36 38 50 52 54 56 58 70 1 3 89Y 22 8 2 21 1 2 21 14 14 44 89X 89Y 89Y 13 13 43 14 15 16 17 22 24 26 28 40 42 44 46 36 38 50 52 54 56 58 70 Test 1 CCW ()

P P
4a 4b
Position S/W

8a

Auxiliary switch

8b

A1

CS A3 CS A5

LS2 3 4

1 2

LS3

1 3 2 4

Ya

Yb

5 52a 22 8

1 5

89M

M
89X
9 9

52b

30 31

6'

89Y

A4 N

Indication for closing spring "charged" is available.

Note. Diagram shows the circuit breaker in position OFF closing spring Charged with

Vacuum Circuit Breaker for MCSG

1 D 1 C 36 37 38 39 B

2 2

3 3

4 4

10 11 12 13 14 15 16 9 10 D

C 50 51 52 53

B 13 14 15 16 17

A A1 A2 A3 A4 A5 A6 22 23 24 25 26 27 28 29 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ( 4a 4b )

1 D 1 C 36 37 38 39 B

2 2

3 3

4 4

10 11 12 13 14 15 16 9 10 D

C 50 51 52 53 54 55 56 57 58 59 70 71

B 13 14 15 16 17 42 43 44 45 46 47

A A1 A2 A3 A4 A5 A6 22 23 24 25 26 27 28 29 40 41 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ( 8a 8b ) SECONDARY DISCONNECT WIRING ( TOP VIEW )

: External terminal of VCB 52 : Vacuum circuit breaker M : Spring charging motor TC : Trip coil TC1 : Secondary trip coil C : Closing coil Y : Anti-pump relay 52a : Auxiliary switch (NO) 52b : Auxiliary switch (NC) LS1 : Closing interlock limit switch(only withdrawable type) LS2 : Motor stopping, closing spring charged indication LS3 : Anti-closing, Anti-pumping limit switch LS5 : "Off" at Test Position LS6 : "Off" at Run Position PS1 : Position S/W("On" at Test Position) PS2 : Position S/W("On" at Run Position) 89X : Auxiliary Relay for Inserting 89Y : Auxiliary Relay for withdrawing 89M : Motor for withdrawing and Inserting

Dimensions
Cradle(Compartment) - w/o Earthing Switch
Front
A 70 103 75 Lead wire (2m)

<A-A Section View>


180 C

293.8 263.8 10 st:310

Rear
45 372.6 60 425 2-13 30 265 425 265 175 (Earthing) 6.5 95 60 968 1000

1365

340

1365

425

1082

265

265 B 183.4
TEST RUN

(183.4)

(212.4)

B
1

15.4

95

652.4

35

53

894 1000

53

410

963

553

Earthing

Top
<Front>
410 65

<B-B Section View>


<Rear> <Front>
3-11 (Mounting Hole) User Bus 205

<Rear>
3-1122 (Mounting Hole)

45

<C-View(Cover 2 Cutting)>

700 175 103

20

370

40

513

16.8 600 950

700

128 50

265

20-M8 POP NUT (DP:18)

844

50

340

40

963

483

50

15

933

(15)

G type breaker + track(electric draw-in/out)


630A
265 265 445

2000A
340 445

1013

860 886 912

350 481 785

50

608

340

30

86

340

26.8

3-10

190

86

H2-5

Vacuum Circuit Breaker for MCSG


Dimensions
Cradle(Compartment) - w/ Earthing Switch

Front
A 125

Side
35

16-10 (Mounting Hole Side)

Rear
35 238.8 25t(2000A) 10t(630/1250A) Test st:310 Run 10-M8 POP NUT (DP:18) 45 398.6 415

500

1750

500

415

(Door) **Option

340

3-10

767.4

415

User Bus 36 500

265 (Earthing) 6.5

265 175

Test

415

M12 TAP (DP:24) 244 265 45 265 454

1000

39

963

35

(Earthing S/W) **Option 320.9

125

968

Top
<Front> <Rear>
25

<B-B Section View>


<Front> <Rear>

<Terminal conductor>
26 17 60 2-13 26

9-11Mounting Hole 20 370 40 513 16.8 600 65 19 15 700 950 340 83

50

20-M8 POP NUT (DP:18) 25

140 150

60 70 100 763 100

50

340

40

483

50

H2-6

26

26

17

83

190

74

Test

Power Plants

VCB
H3-4 H3-5 H3-6 H3-8 H3-14

Vacuum Circuit Breaker for Power Plants


Ratings Ratings of Accessories Accessories Control circuit diagram Dimensions H3-9 Types and ordering information

Contents

H3

Vacuum Circuit Breaker


Power Plants
A product developed for water and thermal power plants due to the revision and application of Kepcos standard (ES150) followed by the IEC standard revision. It has completed the high capacity (40~50kA) VCB series for power plants by securing higher breaking capacity, safety and reliability.

VCB Full Option


To prevent fatal error, property and life loss caused from operator during operation, it is equipped with safety mechanisms such as shutter padlock.

Bushing applied for Window CT adaptation


The bushing provides sufficient strength to collaborate with the internal insulation and is adaptable with CT offering safety mechanically and electrically when applying large current.

H3-2

Vacuum Circuit Breakers for Power Plants

It is recognized for reliability by acquiring new IEC 62271-100 and ES150 (KEPCO standard specification on AC breakers)

H3-3

Vacuum Circuit Breaker for Power Plants


Ratings
Type Rated voltage Rated normal current Rated frequency (kV) (A) (Hz) 40 500 40 104 3 0.04 0.06 20 60 CO-15s-CO (A) (A) (A) 5 (at DC125V) 3 (at DC125V) 3 (at DC125V) M2 E2 (Maintenance free) C2 10000 operations 20000 operations 10000 operations 20000 operations 3a3b Visible, Tulip (kg) 200 190 ES150 NOTE) KERI 260 230 200 190 260 230 IEC 62271-100 200 190 260 230 E2 (List1) O-0.3s-CO-3min-CO 5 (at DC110V) 3 (at DC110V) 3 (at DC110V) 1200 2000 3000 1250 2000 60 50 624 50 130 LVB-06G-40H LVB-06G-40J 7.2 2500 3150 1250 2000 3150 LVB-06G-50J

Rated short-circuit breaking current (kA) Rated short-circuit breaking capacity (MVA) Rated short-time withstand current (kA/3sec) Rated short-circuit making current (kAp) Rated breaking time Rated opening time No-load closing time Withstand voltage Power frequency Impulse (kV/1.2 (Cycle) (sec) (sec) (kV/min) 50 )

Rated operating sequence Rated charging motor current Rated closing coil current Rated shunt coil current Type test Mechanical Electrical Capacitive current switching Lifetime Mechanical Without maintenance Maintenance Electrical Without maintenance Maintenance Auxiliary switch Installing Draw-out G-type G-type G-type (kg)

Weight Breaker Cradle Applied standard Type test laboratory

Note) ES150: KEPCO's standard in which IEC62271-100 is applied KERI: Korea Electrotechnology Research Institute

H3-4

Ratings and auxiliary devices


Motor
When the closing spring is charged, the control power of motor is turned off by the built-in limit s/w.
Rated voltage DC 110V DC 125V The peak value of the inrush current (A) 20 20 Rated current (A) 3 3 Consumption power (W) 330 330 Charging time (Sec.) 12 12

Note) Range of the normal operating voltage: 85~110% of rated voltage

Closing Coil (C)


When the rated volt is applied to the coil the breaker is closed. The electrical anti-pumping circuit is built-in it.
Rated voltage DC 110V DC 125V Rated current (A) 3 3

Shunt coil (TC)


When the rated volt is applied to the coil the breaker is opened.
Rated voltage DC 110V DC 125V Rated current (A) 3 3

Note) Range of the normal operating voltage: 75~125% of rated voltage

Note) Range of the normal operating voltage: 60~125% of rated voltage

Auxiliary switch
Standard configuration : 3a3b1b of early-b contact function exists inside
Classification Contact Ratings DC 110V 10 125V 10 Resistive load (A) Inductive load (A) 5 5 Contact configuration 3a3b

Position of the Auxiliary switch


Switch Breaker a RUN CLOSE OPEN CLOSE OPEN ON OFF OFF ON ON OFF Mechanism b a ON OFF MOC b OFF ON a ON OFF TOC b OFF ON

Note) The contact ratings of Mechanical Operated Cell Switch(MOC) are the same with that of the Aux. switch.

Truck Operated Cell Switch(TOC)


Classification Contact Ratings DC 110V 10 125V 10 Resistive load (A) Inductive load (A) 5 5 Contact configuration 3a3b

TEST

ON * OFF * ON OFF OFF * ON * OFF ON

OFF ON

Note) * applied in the VCB of which MOC is operable at the TEST position.

Charge indicator of the closing spring


Indicating the condition of the closing spring.

Position indicator of the main contacts


Indicating the 'Close' or the 'Open' of the main contacts. Close position: ON Open position: OFF

Charged

Discharged Close position Open position

Counter
Mechanically counts the operation of the VCB by 5digits H3-5

Vacuum Circuit Breaker for Power Plants


Accessories
Accessories for breakers
Position padlock
It is located at the screw hole to prevent the draw-in and out of a breaker from the present position(Disconnected, Test or Connected)

Mechanical position indicator


It is located in the lower part of a breaker to check the present position Disconnected, Test or Connected- easily.

Position interlock
The breaker is locked in each position-Disconnected, Test or Connected, thus it is necessory to release the lock before draw-in or out of a breaker from the present position.

Auto connection
When the breaker is moved to Test position from Disconnected position the connector for control powers is automatically connected. In case of reverse moving of the breaker the connector is automatically disconnected.

Code plate
When the breaker is inserted to the cradle, if the ratings does not match with the cradle, it mechanically prevents the breaker from being inserted into the cradle.

H3-6

Accessories for breakers


Mechanically operated cell switch (MOC)
It is auxiliary switch (6a6b), which indicates the 'ON' or 'OFF' condition of a VCB, and operated when the VCB is in 'Run' state.

Truck operated cell switch (TOC)


It is auxiliary switch (6a6b), which indicates the 'Run' state of a VCB and is operated by the movement of a VCB frame.

H3-7

MOTOR POWER SOURCE

LS4 2 2

1 LS1 2

CLOSING POWER SOURCE

6 8

TC A6 N
23

TRIP POWER SOURCE

H3-8

<TOC>

Cell switch in service position

15 16 17

25 26 27

12 13 14

22 23 24

<MOC> P
Auxiliary switch
22 26 3a 24 54 58 3b 56

15 16 17

30 34 36 38 50 52

P A1
LS2 3 4 6 52a 23 25 22 24 26 27 7 1 4 Ya 6 54 55 LS3

P CS A5

25 26 27

31 35 37 39 51 53

12 13 14

6 22 24 26 28 40

CS A3

Control circuit diagram

22 23 24

7 23 25 27 29 41

56 57

58 59

M Y

1 3 2 4 1 Yb 5 52b 30 31 3

A2 N

A4

25

27

55

57

59

Early b

Note) Diagram shows the circuit breaker in position OFF closing spring Charged with

A1 A3 A5 A2 A4 A6 22 24 26 23 25 27

56 57

54 55 58 59

A
13 14 15 16 17 18 19 20

Vacuum Circuit Breaker for Power Plants

(12P TAP PLUG)


21 22 23 24

A2 A4 A6 23 25 27 A1 A3 A5 22 24 26
1 2 3 4 5 6 7 8 9

55 57 59 54 56 58
10 11 12

52 M TC C Y 52a 52b LS1 LS2 LS3 LS4

: : : : : : : : : : : :

External terminal of VCB Vacuum circuit breaker Spring charging motor Trip coil Closing coil Anti-pump relay Auxiliary switch (NO) Auxiliary switch (NC) Closing interlock limit switch Motor stopping Anti-closing, Anti-pumping limit switch Motor Charging interlock limit switch

SECONDARY DISCONNECT WIRING (FRONT VIEW OF RECEPTACLE PLUG)

Dimensions - Breakers
LVB-06G-40H, 40J G class (Visible, Tulip contact)-(1200, 1250, 2000A)
Front
722

(unit : mm)

336

351.3

815.2

130

60 10

696 717

686.2

Top
254 254

<Conductor>

532

584

685.2

1200/1250/2000A
745

368.2

360

54(male conductor)

Side

H3-9

Vacuum Circuit Breaker for Power Plants


Dimensions - Breakers
LVB-06G-40H, 40J G class (Visible, Tulip contact)-(2500, 3000, 3150A)
79(male conductor) 10 368.2 60 360 Heat sink (only for 3150A)

(unit : mm)

Front
722

Side
336

349.8

696 717

815.2

130

686.2

Top
254 254

<Conductor>

584

685.2

532

2500/3000/3150A
745

H3-10

LVB-06G-50J G class (Visible, Tulip contact)-(1250, 2000A)


Front Side

(unit : mm)

722 115.5 140 336

Moving contact 360

Fixed contact

130

341.3

403.8

815.7

60 10

696 717

677.2

Top
254 254

532

745

584

676.2

368.2

54(male conductor)

H3-11

Vacuum Circuit Breaker for Power Plants


Dimensions - Breakers
LVB-06G-50J G class (Visible, Tulip contact)-(3150A)
Front Side
79(male conductor) 150.2 10 358.7 360 Fixed contact

(unit : mm)

722 115.5 140

336

Moving contact

130

107 341.8 267.8 136.5 815.7

445.8 696 717 677.2 541

Top
254 254

532

H3-12

584

676.2

Cradles

(unit : mm)

4-M12 DP20

252 50 35

374 240 150 500

1134 361

218

79 148

14
(Earthing)

310 50

2500/3000/3150A
2-M12 DP20 252 35 374 240

816 776 103.5 175

140

123

235.5

218

36

148

310

54

436.5 140 123 544

Mounting 6- 12

Autocon(3a3b) M.O.C(6a6b)

1200/1250/2000A

338

59 61()

1035

644 61

151.5

T.O.C(6a6b)

1038.5

75.8

449.5

360

254

254

H3-13

Vacuum Circuit Breaker for Power Plants


Types and ordering information
Breaker

LVB
LS VCB

06

G
Installation method G G class draw-out

40

J
Standard H J ESB150 IEC

12

1A
Control voltage 1A 1B 1E DC110V DC220V DC125V

2L

P3,Q,R

Option C1 Button padlock(ON) C2 Button padlock(OFF) C3 Button padlock(ON/OFF) D1 Button Cover(ON) D2 Button Cover(OFF) D3 Button Cover(ON/OFF) E Button padlock(ON)+ Button cover(OFF) Button padlock(OFF)+ Button cover(ON)

Rated voltage 06 7.2kV

Breaking current 40 50 40kA 50kA 12 20 25 30

Rated current 1200/1250A 2000A 2500A


NOTE1)

Auxiliary switch 2L

NOTE2)

3a3b(Autocon)

3000/3150A

G Key Lock
Note) 1.Rated current 2500A is available only at 7.2kV 40kA, IEC version(J) 2.Control voltage and Auxiliary switch are not applied to Dummy VCB and Earthing Truck

P3 Dummy VCB Q Earthing Truck(lower terminal) R Earthing Truck(upper terminal)

Cradle

LCL
LS Cradle

06

40

12

A1, A2

Installation method G G class draw-out H J

standard ESB150 IEC A1

Option MOC(6a6b)+TOC(6a6b) MOC active only at RUN position MOC(6a6b)+TOC(6a6b) A2 MOC active only at TEST and RUN position

Rated voltage 06 7.2kV 40 50

Breaking current 40kV 50kV 12 20 25 30

Rated current 1200/1250A 2000A 2500A 3000/3150A

H3-14

Nuclear Power Plants

VCB
H4-4 H4-5 H4-6 H4-8 H4-9 H4-11

Vacuum Circuit Breaker for Nuclear Power Plants


Ratings Ratings of Accessories Accessories Control circuit diagram Dimensions Types and ordering information

Contents

H4

Vacuum Circuit Breaker


Nuclear Power Plants
It was developed for KEPCO nuclear power stations. This breaker satisfies quality, safety measures (secure from earthquake and other environments), and surge protection class complies with 1E-CLASS provisions. It is featured with high breaking technologies, safety, and reliability by applying our own vacuum interrupters (50KA) approved by ANSI standard tests.

H4-2

Vacuum Circuit Breakers for Nuclear Power Plants

VCB Full Option


To prevent fatal error, property and life loss caused from operator during operation, it is equipped with safety mechanisms such as shutter padlock.

Bushing applied for Window CT adaptation


The bushing provides sufficient strength to collaborate with the internal insulation and is adaptable with CT offering safety mechanically and electrically when applying large current.

Satisfies earthquake and other internal environment specifications


During the lifespan of power stations (40yrs), it is designed to operate its fundamental breaking functions even under the most severe conditions like earthquake, which is critical from safety perspectives. These technologies proven through tests that comply with KEPIC standard and relevant specifications are to guarantee nuclear reactor safety. H4-3

Vacuum Circuit Breaker for Nuclear Power Plants


Ratings
Type Rated voltage (kV) LVB-05G-50B 4.76 1200 Rated normal current (A) 2000 3000 Rated frequency Rated short-circuit breaking current Rated short-circuit breaking capacity Rated short-time withstand current Rated short-circuit making current Rated breaking time Rated opening time No-load closing time Withstand voltage Rated operating sequence Rated charging motor current Rated closing coil current Rated shunt coil current DC 125V DC 125V DC 125V Mechanical(w/o maintenance) Electrical(w/o maintenance) Auxiliary switch Installing 1200,2000A 3000A Applied standard Type test laboratory (kg) (kg) (A) (A) (A) 5 3 3 10000 operations 10000 operations 5a3b G-type 300 350 ANSI C37 KERI Power frequency Impulse (Hz) (kA) (MVA) (kA/3sec) (kA) (Cycle) (sec) (sec) (kV/1min) (kV/1.2 50 ) 60 50 410 50 130 3 0.04 0.06 19 60 0-0.3s-CO-3min-CO 5 3 3 10000 10000 5a3b G-type 300 ANSI C37 KERI LVB-15G-40B 15 1200 2000 60 40 1040 40 104 3 0.04 0.06 36 95

Lifetime

Weight

H4-4

Ratings of Accessories
Motor
When the closing spring is charged, the control power of motor is turned off by the built-in limit s/w.
The peak value of the inrush current (A) 4.76kV 50kA DC 125V 15 15kV 40kA 15 Ratedcurrent(A) 4.76kV 50kA 5 15kV 40kA 5 90~140 360 8

Rated voltage

Range of the normal operating voltage

Consumption power (W)

Charging time (sec)

Closing Coil (C)


When the rated volt is applied to the coil the breaker is closed. The electrical anti-pumping circuit is built-in it.
The peak value of the inrush current (A) 4.76kV 50kA DC 125V 3 15kV 40kA 3 90 ~ 140

Shunt Coil (TC)


When the rated volt is applied to the coil the breaker is opened.
The peak value of the inrush current (A) 4.76kV 50kA DC 125V 3 15kV 40kA 3 70 ~ 140

Rated voltage

Range of the normal operating voltage

Rated voltage

Range of the normal operating voltage

Auxiliary switch
Standard configuration : Reversible 8C(5a3b) and 2c(2b) with early-b contact function
Classification AC Contact Ratings DC 250V 125V 250V 125V 30V Resistive load(A) 10 10 10 10 10 Inductive load(A) 5 5 5 5 5 8c Contact configuration

Position of the Auxiliary switch


Switch Breaker RUN CLOSE OPEN CLOSE OPEN Mechanism a ON OFF OFF ON OFF ON OFF ON b MOC ab ON OFF TOC ab ON OFF

OFF ON ON OFF OFF ON

OFF ON ON OFF OFF ON

TEST

Note) The contact ratings of Mechanical Operated Cell Switch(MOC) are the same with that of the Aux. switch.

Charge indicator of the closing spring


Indicating the condition of the closing spring.

Position indicator of the main contacts


Indicating the 'Close' or the 'Open' of the main contacts. Close position: ON Open position: OFF

Charged

Discharged Close position Open position

Counter
Mechanically counts the operation of the VCB by 5digits H4-5

Vacuum Circuit Breaker for Nuclear Power Plants


Accessories
Accessories for breakers
Position padlock
It is located at the screw hole to prevent the draw-in and out of a breaker from the present position(Disconnected, Test or Connected)

Mechanical position indicator


It is located in the lower part of a breaker to check the present position Disconnected, Test or Connected- easily.

Auto connection
When the breaker is moved to Test position from Disconnected position the connector for control powers is automatically connected. In case of reverse moving of the breaker the connector is automatically disconnected.

Reversible contact
10 auxiliary switches are provided. 8 of them consist of reversible 8c which can be changed from a(b) to b(a). Factory composition is 5a3b. And the other 2 switches are supplied as 2b with early-b contact function

Code plate
When the breaker is inserted to the cradle, if the ratings does not match with the cradle, it mechanically prevents the breaker from being inserted into the cradle.

Auto discharge
In case the breaker is drawn-out when the closing spring is charged in the position-Disconnected, Test or Connected, or the breaker is moved to Disconnected position from Test position the closing spring shall be automatically released.

H4-6

Accessories for cradles


Mechanically operated cell switch (MOC)
This 6a6b switch indicates the 'ON' or 'OFF' condition of a VCB and is operated in the positions of 'Run' and 'Test"..

Truck operated cell switch (TOC)


This 6a6b switch indicates the 'Run' state of a VCB and is operated by the movement of a VCB frame.

H4-7

H4-8

P CS
5a 22 24 26 28 40 54 56 58

P
Auxiliary switch
3b

CS A5

A1

A3

LS2 3

LS3

Yb 6 52a 23 34 25 36 27 38 29 50 41 52 6 1 22 35 24 37 26 39 28 51 40 53

2 1

4 Ya 6 43 54 45 56 47 58

Control circuit diagram

M
7

52b

5 30

TRIP POWER SOURCE

CLOSING POWER SOURCE

MOTOR POWER SOUREC

31

42 55 44 57 46 59

C Y
8

LS1

1 2 23 25 27 29 41

TC

A2 N

A4

A6

55

57

59

early b

13

14

15

16 17

18

19

20

21

22

23

24

A2 A4 A6 23 25 27 29 41 A1 A3 A5 22 24 26 28 40
1 2 3 4 5 6 7 8 9

55 54
10

57 59 56 58
11 12

SECONDARY DISCONNECT WIRING (FRONT VIEW OF RECEPTACLE PLUG)

Vacuum Circuit Breaker for Nuclear Power Plants

: External terminal of VCB 52 : Vacuum circuit breaker M : Spring charging motor TC : Trip coil C : Closing coil Y : Anti-pump relay 52a : Auxiliary switch (NO) 52b : Auxiliary switch (NC) LS1 : Closing interlock limit switch (only withdrawable type) LS2 : Motor stopping, closing spring charged indication LS3 : Anti-closing, Anti-pumping limit switch

Note) Diagram shows the circuit breaker in position OFF closing spring Charged with

Dimensions
Breaker
722 254 254

722 745

<Front view>

109

228

109

228

360

817

369

816

3000A

86.5 109.5 442.5 713

1200/2000A

<Side view>

360

H4-9

Vacuum Circuit Breaker for Nuclear Power Plants


Dimensions
Cradle
936 254 254

644 850

<Front view>
343 137

100

252 213

310

36

360

1070

2-M12 DP24

1200/2000A

449

50

157

195

630 1020

3000A

2-M12 DP24

<Side view>

H4-10

203 4-M12 DP18

Types and ordering information


Breaker

LVB

05

40

20

1A

2K

LS VCB

Installation method G G class draw-out B

Version Pro-MEC 1A 1B 1C 1E

Control voltage Note) DC110V DC220V DC48V DC125V 1 2

Nuclear class 1E class Non 1E class

Note) 1A,1B,1C are only available at 15kV class

Rated voltage 05 15 4.76kV 15kV 40 50

Breaking current 40kA 50kA 12 20 30

Rated current 1200A 2000A 3000A 2K

Auxiliary switch 8c

Cradle

LCL

05

40

20

LS Cradle G

Installation method G class draw-out B

Version Pro-MEC 1 2

Nuclear class 1E class Non 1E class

Rated voltage 05 15 4.76kV 15kV 40 50

Breaking current 40kA 50kA 12 20 30

Rated current 1200A 2000A 3000A

H4-11

Memo

H4-12

For your safety, please read user's manual thoroughly before operating. Contact the nearest authorized service facility for examination, repair, or adjustment. Please contact a qualified service technician when you need maintenance. Do not disassemble or repair by yourself!

Safety Instructions

Any maintenance and inspection shall be performed by the personnel having expertise concerned.

2008.11 LSIS Co.,Ltd. All rights reserved.

www.lsis.biz

HEAD OFFICE

Global Network LSIS (Middle East) FZE Dubai, U.A.E. Dalian LSIS Co., Ltd. Dalian, China LSIS (Wuxi) Co., Ltd. Wuxi, China
Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab Emirates Tel: 971-4-886 5360 Fax: 971-4-886-5361 e-mail: jungyongl@lsis.biz Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: xuhg@lsis.com.cn Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: srjo@lsisvina.com Address: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, Vietnam Tel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: sbpark@lsisvina.com Address: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. China Tel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: jinhk@lsis.com.cn Beijing 100013, P.R. China Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: cuixiaorong@lsis.com.cn

Korea Gyeonggi-do Anyang-si dongan-gu LS-ro 127 (Hogye-dong) Tel. (82-2)2034-4887, 4873, 4918, 4148 Fax. (82-2)2034-4648

CHEONG-JU PLANT

LSIS-VINA Co., Ltd. Hanoi, Vietnam

Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, 361-720, Korea

LSIS-VINA Co., Ltd. Hochiminh , Vietnam LSIS Shanghai Office Shanghai, China

LSIS Beijing Office Beijing, China Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District, LSIS Guangzhou Office Guangzhou, China LSIS Chengdu Office Chengdu, China LSIS Qingdao Office Qingdao, China

Address: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. China Tel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: linsz@lsis.biz Address: Room 1701 17Floor, huanminhanjun internationnal Building, No1 Fuxing Road Chengdu, 610041, P.R. China Tel: 86-28-8670-3101 Fax: 86-28-8670-3203 e-mail: yangcf@lsis.com.cn Address: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. China Tel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: lirj@lsis.com.cn Address: 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands Tel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: junshickp@lsis.biz Address: 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India

LSIS NETHERLANDS Co.Ltd Qingdao, Netherlands

Specifications in this catalog are subject to change without notice due to continuous product development and improvement.

LSIS Gurgaon Office Gurgaon ,India

2011. 10

Vacuum Circuit Breakers/Vacuum Interrupter(E) 2008. 11/(05) 2011. 10 Printed in Korea