MwRwS

INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.


VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT

MwRwS

COMPANY PROFILE
Legal Status:
The company is 100% privately-owned

Established:
August 1989

Owner and General Manager:


Mr. Georg Renn

Employees:
3 persons full time, more on part time if required

MwRwS

Main Business Activities:


Trade in hydraulic, mechanical and electronic components as well as spare parts for these components. (Import, Export) Advisory services for customers in the domains of maintenance and repairs as well as acquisition of spare parts and logistics. Development, design and manufacturing of special-tools and equipment like the EMT. The main customer are the Austrian Armed Forces, of course, but we produce and provide services for several other Armed Forces and private companies too.

MwRwS

Quality Management System:


All our business activities are planned and executed in accordance with the requirements written down in our Quality Management Handbook. Our quality management system, in accordance with ISO 9001:2000 (EN ISO 9001:2000) has been approved and certified since 2000-04-26 by LLOYD`S REGISTER QUALITY ASSURANCE

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA

EQUIPMENTS FOR MAINTENANCE AND TESTING


EMT-M60(E)

EMT-M109

EMT-LEO2

PRESENTATION VIDEO

EXIT

EMT, PRESENTATION VIDEO

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M60(E)

EMT-M60(E)

EQUIPMENT FOR MAINTENANCE AND TESTING


WHAT IS THE EMT-M60(E)?

EMT-M60(E)

The Equipment For Maintenance And Testing EMTM60(E) was designed to be used by the maintenance staff in order to carry out all inspection and maintenance tasks on M60A3 Tank Turrets on whatever maintenance level.

It consists of the following main components:

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M60(E)

THE BASIC EQUIPMENT Provides the necessary electric and hydraulic power. The Power Pack is electronically (programmed) remote-controlled. Includes all necessary adaptors and connection hoses.

THE ACCESSORIES Special adaptors enabling connections with the M60s units. Several flexible hoses to convey hydraulic fluid and nitrogen. A Pressure Regulator and Pressure Gauges. Valve Opener for nitrogen filling valves.

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M60(E)

THE GYMNASTICATION DEVICE Serves to gymnasticate the gun. Is installed/uninstalled in several minutes. Once installed, the gymnastication can be repeated remote-controlled as often as necessary.

THE PURGING AND FILLING KIT Serves to carry out all purging and filling tasks on the Fire Control and Sighting equipment.

EQUIPMENT FOR MAINTENANCE AND TESTING


EMT-M60(E), APPLICATION TABLE

EMT-M60(E)

According to TM9-2350-253-20-2. Page 2-8 and following pages, the below listed tasks can be performed by using the EMT-M60(E)
TASK NO. 07 (01) 08 (02) 25 (03) 26 (04) 27 (05) 28 (08) 29 (06) 30 (07) 42 (08) 44 (09) ITEM TO BE INSPECTED Manual Elev. Accumulator Nitrogen PROCEDURE Recharge manual accumulator (see para 2-10f) ASSEMBLIES of the EMT-M60(E) to use Filling and Purging Kit SCHEDULE

QUARTERLY

Exercise recoil mechanism Recoil Mechanism (see TM9-2350-253-34-2, Exercise para 3-259, page 3-238) Commander's Purge and charge (see para Periscope M36E1 2-24, page 2-43f) Gunner's Purge and charge (see para Periscope M35E1 2-24, page 2-43f) Tank Thermal Sight (TTS) Laser Range Finder, R/T Unit Reticle Projector Unit Telescope M105D Hydraulic Power Pack and related assemblies Purge and charge the all TTS Units (see 2-24, page 2-48) Purge and charge (see para 2-24, page 2-46f) Purge and charge (see para 2-24, page 2-46f) Purge and charge (see para 2-24, page 2-46f) Turret Hydraulic System service (para 2-10, page 220f)

Basic Equipment, Accessories and Gymnastication Device Filling and Purging Kit Filling and Purging Kit Filling and Purging Kit Filling and Purging Kit Filling and Purging Kit Filling and Purging Kit

QUARTERLY

QUARTERLY QUARTERLY QUARTERLY QUARTERLY QUARTERLY QUARTERLY

Basic Equipment and Accessories

ANNUALLY

Recoil Mechanism Exercise recoil mechanism and 105 mm (see TM9-2350-253-34-2, Cannon para 3-259, page 3-238)

Basic Equipment, Accessories and Gymnastication Device

BIANNUALLY

EQUIPMENT FOR MAINTENANCE AND TESTING


GYMNASTICATION OF GUN M68 BY USING THE GYMNASTICATION DEVICE APART FROM GYMNASTICATION (BY USING THE GYMNASTICATION DEVICE) THE FOLLOWING TASKS CAN BE CARRIED OUT Gymnastication without using the GymnasticationDevice by pumping hydraulic fluid into the Recoil Mechanism. Filling or bleeding of the Replenisher. Filling and bleeding of the Recoil Mechanism (Mount M140). Changing of the Gun Mounts hydraulic fluid. Filtering of the Gun Mounts hydraulic fluid (instead of changing it).

EMT-M60(E)

NOTE: In order to execute the above mentioned tasks, the Gun Mount M140 must be equipped with quick release couplings. We can supply an approved Modification Kit (P/N 930004). The modification can be done at the organizational maintenance level in some hours.

GYMNASTICATION OF GUN M68 WITHOUT USING THE GYMNASTICATION DEVICE

EQUIPMENT FOR MAINTENANCE AND TESTING


KIT, MODIFIKATION, GUN MOUNT M140 (M140A1) P/N 930004
1 SCOPE

EMT-M60(E)

This Modification Kit serves to prepare any Gun Mount M140 (M140A1) for the most advantageous use of the EMT-M60(E) in order to carry out inspection and maintenance tasks on the Gun Mount and its related parts. The Kit can be applied by the technician staff on the organizational maintenance level in several hours. 2 CONTENT OF THE KIT 3 3.1 APPLICATION OF THE KIT Remove and discard following items:

One Kit contains: 1 EA P/N 210011 HOSE,FLEXIBLE,CRADLE TO REPLENISHER 1 EA P/N 210015 ADAPTOR,CRADLE,GUN MOUNT TO EMT 1 EA P/N 611005 COUPLING,QUICK RELEASE, MALE, TYPE SG-006 1 EA P/N 612062 ELBOW, ADJUSTABLE, LOCKNUT,7/16-20UNF 1 EA P/N 612065 UNION,SWIVEL,08L,M14x1,5

EQUIPMENT FOR MAINTENANCE AND TESTING


3.2 Install following items:

EMT-M60(E)

TO REPLENISHER

DOCUMENTATION

Rework drawings and instructions are available. Document numbers are the same as the P/N of the kit.

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M60(E)

TASKS TO CARRY OUT ON THE FIRE CONTROL SYSTEMS COMPONENTS TASKS TO CARRY OUT ON THE HYDRAULIC GUN LAYING SYSTEM Charging of the Manual Accumulator. Charging of the Main Accumulator. Bleeding of the Elevation Cylinder and Superelevation Actuator. Filling hydraulic fluid into the Power Packs Reservoir Filling or changing the Power Packs hydraulic fluid. Purging and filling of sighting and fire control instruments as there are: Periscopes M35E1 and M36E1 Telescope M105D Laser Range Finder Reticle Projector and Units of the TTS-System

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M60(E)

ADVANTAGES OF THE EMT Simple, safe and soldierproof handling. Only minor and low-cost modifications on the weapon systems are needed. Time and cost savings. E.g.: At least 80 % in case of gymnastication. Compact and lightweight design makes it very transportable. Electrical power supply directly from the vehicle or another 24V DC-source. Hydraulic circuits and assemblies are protected against oil impurity. Avoiding environmental contamination. The maintenance staff is protected from accidents or other health injuries.

EQUIPMENT FOR MAINTENANCE AND TESTING


GENERAL CHARACTERISTICS
Basic Equipment Dimensions: Weight: Max. pressure: Power supply: 550 x 350 x 370 mm 50 kg 250 bar 24V DC

EMT-M60(E)

NOTE:
APART FROM THE M60A3 TANK, EMTS ARE ALREADY IN USE TO CARRY OUT INSPECTION AND MAINTENANCE TASKS ON OTHER WEAPON SYSTEMS.

Gymnastication Device NOTE: THE SHOWN EQUIPMENT IS THE MOBILE VERSION. A STATIONARY VERSION IS ALSO AVAILABLE Dimensions: Weight: Max. pulling force: 550 x 350 x 270 mm 26 kg 2,5 t

FOR DETAILS SEE THE VIDEO PRESENTATION.

For further information please contact:

MwRwS Industrievertretungen und Handelsges.m.b.H. Wehlistrasse 27 A-1200 WIEN AUSTRIA Phone: +43-1-3308395 Fax: +43-1-3308395-3 E-Mail: mrs@aon.at

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-LEO2

EMT-LEO2

EQUIPMENT FOR MAINTENANCE AND TESTING


WHAT IS THE EMT-LEO2? This equipment was designed to be used by the maintenance staff in order to carry out several inspections, maintenance or repair tasks on the LEO2 tank turrets. This equipment (system) can be used on all maintenance levels, whether in the field or in the workshop.

EMT-LEO2

THE EQUIPMENT CAN BE USED FOR:


Gymnastication of gun recoil mechanisms on complete vehicles. Checking, draining, refilling or purging of recoil brakes and recuperators. Filling, draining or checking of nitrogen-charged accumulators

It consists of the following main components:

EQUIPMENT FOR MAINTENANCE AND TESTING


THE BASIC EQUIPMENT
Provides the necessary electric and hydraulic power. The hydraulic fluid is automaticall filtered. The filter rate is 3. The Power Pack is electronically (programmed) remote-controlled. Includes all necessary adaptors and flexible hoses with quickrelease couplings.

EMT-LEO2

THE ACCESSORIES Contains special adaptors enabling connections with the LEO2 items, several flexible hoses with quick-releaase or screwed connectors to convey hydraulic fluid and nitrogen. A Pressure Regulator and Pressure Gauges. A Valve Opener for nitrogen filling valves (Schrader type valves). CHECKING AND ADJUSTING THE NITROGEN PRESSURE OF A RECUPERATOR

EQUIPMENT FOR MAINTENANCE AND TESTING


THE GYMNASTICATION DEVICE Serves to push back and release the guns tube. The device is installed / uninstalled within several minutes. To carry out several tasks properly, the return-in-battery velocity can be reduced Once installed, the gymnastication can be repeated remote-controlled as often as required.

EMT-LEO2

GYMNASTICATION BY USING THE GYMNASTICATION DEVICE

ELECTRICAL POWER SUPPLY DIRECTLY FROM THE VEHICLE

EQUIPMENT FOR MAINTENANCE AND TESTING


EMT-LEO2, APPLICATION TABLE
TASK NO. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 ITEM TO WORK ON Recoil Mechanism Recoil Mechanism Recoil Brakes Recoil Brakes Recoil Brakes Recoil Brakes Recoil Brakes TASK TO ACCOMPLISH Gymnastication (return in battery with velocity normal) Gymnastication (return in battery with velocity reduced) Replacement of the brake's supports Refilling and purging (hydraulic fluid) Adjusting of Piston rods ASSEMBLIES of the EMT-LEO2 to use Basic Equipment and Gymnastication Device Basic Equipment and Gymnastication Device Basic Equipment and Gymnastication Device Basic Equipment, Gymnastication Device and Accessories Basic Equipment and Gymnastication Device

EMT-LEO2

Empty the brakes, replacement of the Basic Equipment, Gymnastication Device and brakes Accessories Replacement of the filling adaptors Basic Equipment and Gymnastication Device Accessories Accessories Basic Equipment, Gymnastication Device and Accessories Accessories Basic Equipment and Gymnastication Device Basic Equipment, Gymnastication Device and Accessories Accessories Basic Equipment, Gymnastication Device and Accessories Basic Equipment and Gymnastication Device Basic Equipment and Accessories

Recuperator (hydro Discharging the hydraulic chamber pneumatic) Recuperator (hydro Checking and adjusting the nitrogen pneumatic) pressure Recuperator (hydro Charging of the hydraulic chamber, pneumatic) adjusting nitrogen pressure Recuperator (pneumatic) Recuperator Recuperator Checking and adjusting the nitrogen pressure Adjusting the piston rod Replacement of the Recuperator

Recuperator (hydro Replacement of the filling adaptor pneumatic) Recuperator (hydro Replacement its hydraulic fluid pneumatic) Breech block mechanism Hydraulic Power Pack Adjusting of the control came Filtering and replacement of the hydraulic fluid

EQUIPMENT FOR MAINTENANCE AND TESTING


ADVANTAGES OF THE EMT No modifications on the weapon system itself are needed, no changes for the tank crew. The handling of the EMT is simple, safe and soldier proofed. Using the EMT saves costs and time. E.g.: At least 80 % in case of gymnastication. Electrical power supply for the EMT can be taken directly from the vehicle or from another 24V DC-source. Hydraulic circuits, recoil brakes and recuperators are protected against oil impurity, because all hydraulic fluid delivered by the EMT is automatically filtered. Using the EMT avoids environmental contamination and protects the maintenance staff from accidents or other health injuries.

EMT-LEO2

EQUIPMENT FOR MAINTENANCE AND TESTING


GENERAL CHARACTERISTICS
Basic Equipment Dimensions: Weight: Max. pressure: Power supply: 550 x 350 x 370 mm 50 kg 250 bar 24V DC

EMT-LEO2

NOTE:
APART FROM THE LEO2 TANK, EMTS ARE ALREADY IN USE TO CARRY OUT INSPECTION AND MAINTENANCE TASKS ON OTHER WEAPON SYSTEMS.

Gymnastication Device NOTE: THE SHOWN EQUIPMENT IS THE MOBILE VERSION. A STATIONARY VERSION IS ALSO AVAILABLE Dimensions: Weight: Max. pulling force: 550 x 350 x 270 mm 26 kg 54 kN

FOR DETAILS SEE THE VIDEO PRESENTATION.

For further information please contact:

MwRwS Industrievertretungen und Handelsges.m.b.H. Wehlistrasse 27 A-1200 WIEN AUSTRIA Phone: +43-1-3308395 Fax: +43-1-3308395-3 E-Mail: mrs@aon.at

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M109

EMT-M109

EQUIPMENT FOR MAINTENANCE AND TESTING


WHAT IS THE EMT-M109? This equipment was designed to be used by the maintenance staff in order to carry out several inspections, maintenance or repair tasks on the M109 howitzers. This equipment (system) can be used on all maintenance levels, whether in the field or in the workshop.

EMT-M109

THE EQUIPMENT CAN BE USED FOR: Gymnastication of gun recoil mechanisms on complete vehicles. Checking, draining, refilling or purging of hydraulic assemblies. Filling, draining or checking of nitrogen-charged accumulators

It consists of the following main components:

EQUIPMENT FOR MAINTENANCE AND TESTING

EMT-M109

THE BASIC EQUIPMENT Provides the necessary electric and hydraulic power. The hydraulic fluid is automaticall filtered. The filter rate is 3. The Power Pack is electronically (programmed) remote-controlled. Includes all necessary adaptors and flexible hoses with quickrelease couplings.

THE ACCESSORIES Contains special adaptors enabling connections with the M109 items, Several flexible hoses with quick-release or screwed connectors to convey hydraulic fluid and nitrogen. A Pressure Regulator and Pressure Gauges. A Valve Opener for nitrogen filling valves (Schrader type valves).

EQUIPMENT FOR MAINTENANCE AND TESTING


THE GYMNASTICATION DEVICE Serves to pull back and release the guns tube. The device is installed / uninstalled within several minutes. Once installed, the gymnastication can be repeated remote-controlled as often as required.

EMT-M109

GYMNASTICATION BY USING THE GYMNASTICATION DEVICE

EQUIPMENT FOR MAINTENANCE AND TESTING


EMT-M109, APPLICATION TABLE
TASK NO. 01 *02 03 04 *05 *06 *07 *08 *09 *10 11 12 *13 *14 *15 *16 *17 18 19 ITEM TO WORK ON Recoil System Recoil System Breech Ring Cam Replenisher Assy Recoil System Recoil System Recoil System Recoil System Recoil System Recoil System Accomulators (all) and Recuperators Accomulators (all) and Recuperators Travel Lock Actuator Travel Lock Actuator Travel Lock Actuator Elevating Cylinder and Equilibrator Elevating Cylinder and Equilibrator Hydraulik Elevating and Transfersing System Hydraulik Elevating and Transfersing System TASK TO ACCOMPLISH Exercising the Recoil System by using the "Gymnastication Device" (Recoil length max. 450mm) Exercising the Recoil System by using the "Gymnastication Device" (Recoil length max. 900mm) Checking Cam's function and adjustment Checking and Adjusting of its working pressure Bleeding (Purging) the Recoil System including its Buffer Assembly Adding (automatically filtrated) hydraulic fluid to the Recoil System (quantity < 3 liters) Adding (automatically filtrated) hydraulic fluid to the Recoil System (quantity > 3 liters) Sucking off hydraulic fluid from the Recoiul System (quantity < 3 liters) Sucking off hydraulic fluid from the Recoiul System (quantity > 3 liters) Filtering the whole quantity of hydraulic fluid (about 40 litres) instead of replacing it Checking (or reducing) the working pressure (Nitrogen) Filling nitrogen or Increasing its pressure Adding (automatically filtrated) hydraulic fluid (quantity < 3 litres) Sucking of hydraulic fluid from the Travel Lock Actuator (quantity < 3 litres) Checking its function Bleeding (Purging) and Checking their Adding (automatically filtrated) hydraulic fluid and Checking working pressure Sucking off or Adding hydraulic fluid Filtering the whole quantity of hydraulic fluid insted of replacing it ASSEMBLIES of the EMT-M109 to use Basic Equipment and Gymnastication Device Basic Equipment and Accessories Basic Equipment and Gymnastication Device Basic Equipment and Accessories Basic Equipment and Accessories Basic Equipment and Accessories Basic Equipment and Accessories

EMT-M109

IMPORTANT NOTE:
Basic Equipment Basic Equipment Basic Equipment and Accessories Accessories Accessories Basic Equipment and Accessories Basic Equipment Basic Equipment Basic Equipment and Accessories Basic Equipment and Accessories Basic Equipment and Accessories Basic Equipment

Task numbers marked with an asterisk can only be performed if MOD-KIT P/N 930013A was applied previously!

EQUIPMENT FOR MAINTENANCE AND TESTING


GYMNASTICATION OF CANNON M185 (M284) BY USING THE GYMNASTICATION DEVICE APART FROM GYMNASTICATION (BY USING THE GYMNASTICATION DEVICE) THE FOLLOWING TASKS CAN BE CARRIED OUT Gymnastication without using the GymnasticationDevice by pumping hydraulic fluid into the Recoil Mechanism. Filling or bleeding of the Replenisher. Filling and bleeding of the Recoil Mechanism M178 (M182). Changing of the Gun Mounts hydraulic fluid. Filtering of the Gun Mounts hydraulic fluid (instead of changing it).

EMT-M109

NOTE: In order to execute the above mentioned tasks, the Gun Mount M178 (M182) must be equipped with quick release couplings. We can supply an approved Modification Kit (P/N 930013A). The modification can be done at the organizational maintenance level in some hours.

GYMNASTICATION OF CANNON M185 (M284) WITHOUT USING THE GYMNASTICATION DEVICE

EQUIPMENT FOR MAINTENANCE AND TESTING


KIT, MODIFIKATION, GUN MOUNT M178 (M182) P/N 930013A

EMT-M109

SCOPE

This Modification Kit serves to prepare any Gun Mount M178 (M182) for the most advantageous use of the EMT-M109 in order to carry out inspection and maintenance tasks on the Gun Mount and its related parts. The Kit can be applied by the technician staff on the organizational maintenance level in several hours.

CONTENT OF THE KIT

One Kit contains: 1 EA P/N 280014A 1 EA 4 EA 1 EA 1 EA P/N 280017A P/N 611500 P/N 611508 P/N 611527

ADAPTOR,STRAIGHT,RECOIL BRAKE (M109),COMPLET ADAPTOR,BENT 30,RECOIL BRAKE (M109), COMPLET TEST POINT,MINIMESS,1620,7/16-20UNF, TYPE F TEST POINT,MINIMESS, 1620,1/4 NPT, TYPE H CONNECTOR,1/4 NPT,MINIMESS 1620

EQUIPMENT FOR MAINTENANCE AND TESTING


3 3.1 APPLICATION OF THE KIT Remove and discard or reuse following items:

EMT-M109

EQUIPMENT FOR MAINTENANCE AND TESTING


3.2 Install following items:

EMT-M109

ADAPTOR,STRAIGHT, P/N 280014A

ADAPTOR,BENT 30, P/N 280017A

TEST POINT,MINIMESS, P/N 611500

TEST POINT,MINIMESS, P/N 611500

DOCUMENTATION

Rework drawings and instructions are available. Document numbers are the same as the P/N of the kit.

TEST POINT,MINIMESS, P/N 611508

PRESSURE GAGE, P/N 9227371 CONNECTOR,P/N 611527

EQUIPMENT FOR MAINTENANCE AND TESTING


ADVANTAGES OF THE EMT Only minor and low-cost modifications on the weapon systems are needed. The handling of the EMT is simple, safe and soldier proofed. Using the EMT saves costs and time. E.g.: At least 80 % in case of gymnastication. Electrical power supply for the EMT can be taken directly from the vehicle or from another 24V DC-source. Hydraulic circuits, recoil brakes and recuperators are protected against oil impurity, because all hydraulic fluid delivered by the EMT is automatically filtered. Using the EMT avoids environmental contamination and protects the maintenance staff from accidents or other health injuries.

EMT-M109

EQUIPMENT FOR MAINTENANCE AND TESTING


GENERAL CHARACTERISTICS
Basic Equipment Dimensions: Weight: Max. pressure: Power supply: 550 x 350 x 370 mm 50 kg 250 bar 24V DC

EMT-M109

NOTE:
APART FROM THE HOWITZER M109, EMTS ARE ALREADY IN USE TO CARRY OUT INSPECTION AND MAINTENANCE TASKS ON OTHER WEAPON SYSTEMS.

Gymnastication Device NOTE: THE SHOWN EQUIPMENT IS THE MOBILE VERSION. A STATIONARY VERSION IS ALSO AVAILABLE Dimensions: Weight: Max. pulling force: 550 x 350 x 270 mm 35 kg 35 kN

FOR DETAILS SEE THE VIDEO PRESENTATION.

For further information please contact:

MwRwS Industrievertretungen und Handelsges.m.b.H. Wehlistrasse 27 A-1200 WIEN AUSTRIA Phone: +43-1-3308395 Fax: +43-1-3308395-3 E-Mail: mrs@aon.at

MwRwS
INDUSTRIEVERTRETUNGEN UND HANDELSGESELLSCHAFT M.B.H.
VIENNA AUSTRIA
ABOUT US PRODUCTS

EXIT