LARSEN & TOUBRO LIMITED MSQ UP GRADATION (EPCC 1) PROJECT


PROCEDURE FOR JOINT NUMBERING

DATE:-05.11.07 REV.NO.- 0 PROCEDURE NO.LT/MSQ/P/JN/013

CONTENTS:

1. 2.

SCOPE PROCEDURE

APPROVED BY L & T

REVIEWED / APPROVED BY JACOBS

PAGE NO.- 2 of 3

LARSEN & TOUBRO LIMITED MSQ UP GRADATION (EPCC 1) PROJECT


PROCEDURE FOR JOINT NUMBERING 1.0 SCOPE

DATE:-05.11.07 REV.NO.- 0 PROCEDURE NO.LT/MSQ/P/JN/013

This procedure outlines the method of joint numbering on the isometric drawings. This procedure is applicable for MSQ Unit . 2.0 PROCEDURE: After receipt of approved drawing, detailed fabrication & erection scope will be worked out by planning/ piping engineer based on availability of drawing and material. The approved Isometric Drg. Shall be marked with all the weld joints (shop/field) prior to fabrication in the flow direction with a number to identify each weld in the following sequence and one set of this marked Isometric drawing shall be submitted to L&T QC & Jacobs for their reference. 2.1
2.1.1

U/G PIPING Joint Numbering will be marked after receiving of all sheets of individual lines. Butt joints will be marked as a continuation no. J1, J2, J3Jn. Shop joint read as 1,2,3, . & field joint will have the prefix FJ i.e. FJ1, FJ2, FJ3, FJ4

2.1.2 2.1.3

Branch joints will be marked as a continuation number from BR J1, J2, J3Jn. Socket joints will be marked as a continuation number SW J1, J2, J3Jn. Miter joints will have prefix MJ. Re welded joints will have suffix RW to the previous joint number. For example joint number 1 is re welded then it will be marked as 1RW. Cut out joints in Radiography will have suffix N to the previous joint number. Repair joints in radiography will have suffix R1, R2to the previous joint number Penalty joints in radiography will have suffix P1, P2to the previous radiography number. Modification joints will have suffix M to the previous joints. between joint number 2 & 3, then this additional joint number will be marked as 2A.

2.1.4 2.1.5 2.1.6 2.1.7 2.1.8 2.1.9

2.1.10 Additional joints will have suffix A, B, Cfor example an additional joint is coming in

APPROVED BY L & T

REVIEWED / APPROVED BY JACOBS

PAGE NO.- 3 of 3

LARSEN & TOUBRO LIMITED MSQ UP GRADATION (EPCC 1) PROJECT


PROCEDURE FOR JOINT NUMBERING

DATE:-05.11.07 REV.NO.- 0 PROCEDURE NO.LT/MSQ/P/JN/013

2.1.11 This Numbering will be maintained in a welding control database package i.e. ALPS 2.2
2.2.1

A/G PIPING: Joint Numbering will be marked after receiving of all sheets of individual lines. Butt joints will be marked as a continuation no. J1, J2, J3Jn. Shop joint read as 1,2,3, . & field joint will have the prefix FJ i.e. FJ1, FJ2, FJ3, FJ4

2.2.2 2.2.3

Branch joints will be marked as a continuation number from BR J1, J2, J3Jn. Socket joints will be marked as a continuation number SW J1, J2, J3Jn. Miter joints will have prefix MJ. Re welded joints will have suffix RW to the previous joint number. For example joint number 1 is re welded then it will be marked as 1RW. Cut out joints in Radiography will have suffix N to the previous joint number. Repair joints in radiography will have suffix R1, R2to the previous joint number. Penalty joints in radiography will have suffix P1, P2to the previous radiography number. Modification joints will have suffix M to the previous joints. Additional joints will have suffix A, B, Cfor example an additional joint is coming in between joint number 2 & 3, then this additional joint number will be marked as 2A.

2.2.4 2.2.5 2.2.6 2.2.7 2.2.8 2.2.9


2.2.10

2.2.12 This Numbering will be maintained in a welding control database package i.e. ALPS

Note: No joint number will be repeated in the same line number.