Вы находитесь на странице: 1из 89

AXE810 Day 1&2 - Technical Workshop

Group Switch GS890 Network Synchronisation Power systems Earthing Lightning protection

AXE501

GEM Magazine

Power distribution

GEM backplane connection

AXE810

Clock 16k
SCB-RP SCB-RP CGB_0 CGB_1 XDB Device Device IRB Device Device IRB XDB

DEV pos 23

0 1

2 3 4 5

6 7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22

DEV pos SCB-RP XDB Device SCB-RP XDB Device 0 1 2 3 4 5 6 Device IRB CGB_1 Device Device IRB CGB_0 Device Device CDB_0 CDB_1 XDB SCB-RP Device CDB_0 CDB_1 XDB SCB-RP 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Clock 32k-128k

Clock 128k-512k

GS890 switch matrix

Few examples
Must be a rectangle

00

32K

01

02

64K

03

10

64K

11

12

13

20 64K 30

21

22

23

31

32

33

512k

GDSTP

<GDSTP; DISTRIBUTED GROUP SWITCH STATE UNIT CLM-0 CLM-1 UNIT STATE BLSTATE VAR STATUS WO WO 10 MASTER 10 SLAVE STATE BLSTATE

STATE BLSTATE VAR UNIT WO WO WO WO WO WO WO WO WO WO WO 0 0 0 0 0 0 0 0 0 0 0

XM-A-0-0 MUX34-A-0 MUX34-A-1 MUX34-A-2 MUX34-A-3 MUX3-A-0 MUX3-A-1 MUX3-A-4 MUX3-A-5 MUX3-A-8 MUX3-A-12 END

XM-B-0-0 WO MUX34-B-0 WO MUX34-B-1 WO MUX34-B-2 WO MUX34-B-3 WO MUX3-B-0 WO MUX3-B-1 WO MUX3-B-4 WO MUX3-B-5 WO MUX3-B-8 WO MUX3-B-12 WO

GS HW-SW relation
SW NAME NS NSC CLM XM MUX34 MUX3 MUXSP MUXTS CH GIOH HW NAME IRB, LRB no CGB, CDB XDB, XNB DLEB DLHB DLNB TS4B No No NEW HW yes no yes yes Yes no yes no no no

Boards in GEM
Position ROJ Name 0 and 25 SCB-RP 1 and 24 XDB GESB ET1551 GARP-1 CSBP CGB IRB ROJ number 208 323/1,2,3,4 208 304/1,2 208 410/1,2,3 208 306/1 208 16/1,2,3 208 351/1 208 314/1,2 208 316/1

Front views of clock boards

Front view of other boards

Front view of other boards

CLM in GEM

CLM block diagram

Majority choice

GS HW
CGB IRB LRB XDB DLEB ET1551

CGB block diagram

IRB block diagram

LRB block diagram

XDB HW

DLEB block diagram

ET1551

GS loop/exchange cables

GS clock reference cables

GS clock cables

GS vertical cables

GS Horiz cables

Magazine strapping
GEM CDM

AP0&AP1&AP3
AP0 - Magazine Address for RP addressing AP1 - Column Position in Switch Matrix AP3 - Row Position in Switch Matrix AP0 AP1 AP3

AP0 used for the definition of RPS DB Table RPSRPBSPOS as in current BYB501 AP1 & AP3 if incorrect, XM unit will go ABL

AP1&AP3

AP1&AP3

CDM

Variants
CLM XM MUX34 MUX3

CLM&XM variants
Var CLM Meaning 10 11 Clock distribution via the back plane, size 16K Clock distribution via cables, size>16K

Var XM 0 1 2 3

Meaning Normal Rate group switch (XDB) Subrate group switch (XDB) Normal Rate group switch NNRP (XNB) Subrate group switch NNRP (XNB)

MUX34&MUX3 variants
Var MUX34 Meaning 0 Currently only one Variant

Var MUX3 Meaning 0 1 2 3 GDM-H magazine. BFD 516 04 GDM-F magazine. BFD 511 06 DLM magazine (DL2 only). BFD 742 403/2 DLM-DL1 magazine. BFD 742 403/12

Clock variants

Clock performances

Other issues
SAEs SNT connections MUPs Commands

SAEs
Size Alteration
SAE 442 (max NI=512K, steps of 16K)- XMV=0,1 SAE 600 blocks CH and XM (subrate traffic, max NI=128K)- XMV=1

APs
An AP is an access point where one Unit connects to another XM has 22 APs 0 - 21 MUX34 has 4 APs 0 3 MUX3 has 16 APs 0 15 !DL34! !DL3! !DL2!

MUPs

Commands
New commands
For example: GDCOI, GDCOE, GDCOP, GDCVP, GDSTP,GDBLI/E,GDTEI

Possible GS Units
CLM, XM, MUX34, MUX3, MUXSP, MUXTS

Trouble shoot
TEST SYSTEM; TMSIZE=32000; ON IN CLM CLMDISTRFAULT,CLMFAULTIND,CLRFAULT,FAULTYCARD,ROUTTESTINIT; ON IN XM RPXMFAULTINDIC,RPXMTRAFFINDIC,AUTOBLOCINIT,MANBLOCINIT,RPXMDEBUG; ON IN XMH AUTOBLOCXM,MANBLOCXM; ON IN MUX34 RPMUX34FAULT,RPMUX34DEBUG; ON IN MUX3 AUTOBLOCINIT,FAULTINFOPRINT,MUX3TESTR; ON IN ECP5 FAULTYCARD,RPISNTECFAULT,MTESTSNTGSS3R; ON IN ET1551 BSDIPFAULTSIT,RPSDIPFAULTSIT1; ON IN SDP1551 SDIPFAULTSIT; ON IN C7ST2C C7RPLINKFAULT C7RPALIGNFAIL C7RPHWFAULT C7RPTRHFAULT; ON OU XM FAULTYCARD; ON OU XMH AUTOBLOCINIT; ON IN DO:FOR 100 TIMES,P SWD,P IA,; ON OU DO:FOR 100 TIMES,P SWD,P IA,; INIT;

Network Synchronisation
Network sync Time of day

Sync problem

Network Synch in AXE Master-slave

Typical NS set up

NS example

Network sync connection

Clock reference frequencies

NSSTP;
<NSSTP; CLOCK-REFERENCE STATE REF STATE BLS 0E1551,MS-0 EX 1E1551,MS-0 SB RCM-0 SB END

<NSDAP; CLOCK-REFERENCE SUPERVISION DATA AREA OPERATING STATIC DATA REF CLREFINL REFGRP PRI 0E1551,MS-0 1 1 1 1E1551,MS-0 4 1 2 RCM-0 6 2 3 FDL 50 50 200 WDL 10 10 20 ACL A2 A2 A2

NSDAP;

Time of day example

ToD

Time of day connection

GSC

Power & Earthing & Protection


Power and battery Earthing Lightning protection

Power systems

Battery and Power feed

Voltage distribution

st 1

step

nd 2

step

2 steps model

Power expansion

Cables feeds

AXE Earthing

Unbalanced Current

Single point earth system

AXE earth expansion

Lightning protection
Tower Building

Storm

Protection model

Building protection

Tower protection

Area of protection