THE WORLD LEADER IN SEALED

BATTERY POWER FOR


PHOTOVOLTAIC AND ALTERNATIVE
ENERGY APPLICATIONS

APPLICATIONS

Proven Field Experience Since 1983.

Telecommunications

The Absolyte was developed by GNB, in conjunction


with Sandia National Laboratories, as the first sealed,
large capacity, deep-cycle battery for photovoltaic
applications.

Absolyte IIP batteries are ideal for photovoltaic and


alternative energy applications including:
Village Electrification

Residential Power
Railroad Signal
Navigational Aids

Patented MFX positive grid alloy provides excellent


cycle life for photovoltaic applications.

ADDED FEATURES AND BENEFITS

Provides for extended partial state of charge operation


and allows for deep discharge recovery.

Deep discharge recovery

Wide band of temperature operation retains more


capacity in cold temperatures than traditional flooded
batteries.

Does not require separate battery room

Modular steel tray design provides excellent heat


dissipation in high temperature applications to
maximize life.
Housed in protective steel trays designed for
maximum installation flexibility.
Single cell modules simplify transport to remote
locations.
Absolyte IIP is qualified to stack horizontally up to
eight high for use in U.B.C. 1994 Seismic Zone IV
and to ten high for U.B.C. 1997 Seismic Zone IV
(at or below grade).
Eliminates the need for periodic topping up with water
as found in flooded cells. Periodic visual inspections,
voltage readings, and connection retorquing is all that
is required.

Extended partial state of charge operation


Freezing tolerant
Recombination efficiency greater than 99%
Recyclable to world standards
Single cell and stackable modules
Simple cell replacement capability
IEC 896, BS 6290, UL Recognized, ISO 9002 and
designed to meet Telcordia SR4228.

Absolyte IIP Stackable Module Weights and Dimensions

MODULE
TYPE

VOLTS

NOM
AH CAP

LENGTH

(8 HR)

IN

MM

STACKING DIMENSIONS
DEPTH OR
WIDTH
HEIGHT
IN
MM
IN
MM

DOMESTIC
PACKED
WEIGHT

EXPORT
PACKED
WEIGHT

UNPACKED
WEIGHT
LBS
KG

LBS

KG

LBS

KG

50A
6-50A05

12

104

17.19

437

8.53

217

16.22

412

157

71

176

80

228

104

6-50A07

12

152

21.69

551

8.53

217

16.22

412

209

95

228

104

280

127

6-50A09

12

208

26.19

665

8.53

217

16.22

412

252

114

271

123

323

147

6-50A13

12

312

35.19

894

8.53

217

16.22

412

356

162

381

173

433

197

6-90A07

12

256

21.69

551

8.53

217

23.56

599

316

143

335

152

413

187

6-90A09

12

344

26.19

665

8.53

217

23.56

599

396

180

415

188

493

224

6-90A11

12

432

30.69

780

8.53

217

23.56

599

477

216

502

228

581

264

6-90A13

12

520

35.19

894

8.53

217

23.56

599

557

253

582

264

661

300

6-90A15

12

608

39.69

1008

8.59

218

23.56

599

637

289

668

303

747

339

100A
3-100A13

600

19.93

506

8.53

217

26.38

670

328

149

356

162

436

198

3-100A15

696

22.18

563

8.59

218

26.38

670

374

170

408

185

489

222

3-100A17

800

24.50

622

8.59

218

26.38

670

424

192

446

202

528

240

3-100A19

896

26.75

679

8.59

218

26.38

670

470

213

491

223

574

260

3-100A21

1000 29.00

737

8.59

218

26.38

670

515

234

539

245

623

283

3-100A23

1096 31.25

794

8.59

218

26.38

670

561

255

589

267

674

306

3-100A25

1200 33.50

851

8.59

218

26.38

670

608

276

637

289

723

328

3-100A27

1296 35.75

908

8.59

218

26.38

670

653

296

684

310

772

350

3-100A29

1400 38.00

965

8.59

218

26.38

670

704

319

736

334

824

374

3-100A31

1496 40.25

1022

8.59

218

26.38

670

750

340

783

355

873

396

3-100A33

1600 42.50

1080

8.59

218

26.38

670

795

361

829

376

920

417

1-100A39

1800 19.93

506

8.53

217

26.38

670

328

149

356

162

436

198

1-100A45

2088 22.18

563

8.59

218

26.38

670

374

170

408

185

489

222

1-100A51

2400 24.50

622

8.59

218

26.38

670

424

192

446

202

528

240

1-100A57

2688 26.75

679

8.59

218

26.38

670

470

213

491

223

574

260

1-100A63

3000 29.00

737

8.59

218

26.38

670

515

234

539

245

623

283

1-100A69

3288 31.25

794

8.59

218

26.38

670

561

255

589

267

674

306

1-100A75

3600 33.50

851

8.59

218

26.38

670

608

276

637

289

723

328

1-100A81

3888 35.75

908

8.59

218

26.38

670

653

296

684

310

772

350

1-100A87
1-100A93

2
2

4200 38.00
4488 40.25

965
1022

8.59
8.59

218
218

26.38
26.38

670
670

704
750

319
340

736
783

334
355

824
873

374
396

1-100A99

4800 42.50

1080

8.59

218

26.38

670

795

361

829

376

920

417

90A

* Includes 77 mm (3") additional for Module Cover Assembly

Operating Temperature Temperature excursions


between -40C(-40F) to +50C(122F) allowed (battery
performance and life will be affected).

CELL SPECIFICATIONS
140-6300 AH @ 100 Hour Rate
Container and Cover Polypropylene.

Cycle Life 5000 cycles at 20% D.O.D.; 1200 cycles at


80% D.O.D. [at 25C (77F)] with proper charging.

Flame retardant UL94 V-0/28% L.O.I. is optional.


Separators Spun glass, microporous matrix.
Safety Vent 5-10 psi opening pressure, self-resealing.
Terminals Solid copper insert.

Self Discharge 0.5 to 1.0% per week maximum at


25C (77F).
Charge Controller Upper Voltage Settings
at 25C (77F) with a maximum charge current of 5% of
nominal C/100 Amp-hour rating.
2.28 0.02 V.P.C. @ 0-2% D.O.D.
2.33 0.02 V.P.C. @ 3-5% D.O.D.
2.38 0.02 V.P.C. @ >5% D.O.D.
For other temperatures and charge currents,
contact GNB for recommendations.

Positive Plate Patented MFX grid alloy.


Negative Plate Lead calcium grid alloy.
Orientation 50A, 90A, 100A Horizontal.
50A Vertical (Horizontal preferred)

Absolyte IIP Single Cell Module Weights and Dimensions


CELL
TYPE
50A
50A05
50A07
50A11
50A13
50A15
50A19
50A27

UNPACKED
WEIGHT

NOM AH
CAP
(100 HR)

IN

MM

IN

MM

IN

MM

LB

140
210
360
430
510
655
950

3.80
3.80
4.55
5.30
6.05
7.67
10.67

97
97
116
135
154
195
271

6.49
6.49
6.49
6.49
6.55
6.67
6.67

165
165
165
165
166
169
169

16.00
16.00
16.00
16.00
16.00
16.00
16.00

406
406
406
406
406
406
406

32
39
50
58
66
91
124

LENGTH

ASSEMBLY
CONFIGURATIONS
Horizontal Stack Assembly
(Preferred)
Depth is overall, including
module cover assembly. Add
102mm (4) for bottom I-beam
supports to determine total
height (width) of assembled
horizontal stack.

WIDTH

DEPTH OR HEIGHT

NOTE: Design and/or


specifications subject
to change without
notice. If questions
arise, contact your
local GNB sales
representative for
clarification.

KG

15
18
23
26
30
41
56

DOMESTIC PACKED EXPORT PACKED


WEIGHT
WEIGHT
LB

35
41
53
61
69
95
130

KG

16
19
24
28
31
43
59

LB

KG

44
51
61
69
77
112
147

20
23
28
31
35
51
67

Absolyte IIP Performance Characteristics Constant Current


Amperes to 1.75 Volts Per Cell @ 25C (77F)
HOURS

CELL
TYPE
50A

120

100

72

48

36

24

20

12

10

50A05
50A07

1.2
1.8

1.4
2.1

1.9
2.9

2.8
4.2

3.6
5.5

5.1
7.7

6
9.1

9.3
14

11
16

13
19

50A09
50A11
50A13
50A15
50A19
50A27

2.4
3.1
3.7
4.3
5.6
8.0

2.9
3.7
4.3
5.1
6.6
9.5

3.9
5.0
5.9
6.9
8.9
13

5.6
7.1
8.5
10
13
19

7.3
9.2
11
13
17
24

10
13
15
18
23
34

12
15
18
21
27
39

18
23
28
33
42
61

22
27
33
38
49
71

26
33
39
46
59
85

90A
90A07
90A09
90A11
90A13

3.0
4.0
5.0
6.1

3.6
4.8
6.0
7.2

4.9
6.5
8.1
9.8

7.0
9.4
11
14

9.1
12
15
18

12
17
21
25

15
20
25
30

23
31
39
47

27
36
46
55

32
43
54
65

90A15
100A

7.1

8.4

11

16

21

30

35

55

64

76

100A13
100A15
100A17
100A19
100A21
100A23
100A25
100A27
100A29
100A31
100A33
100A39
100A45
100A51
100A57
100A63
100A69
100A75
100A81
100A87
100A93
100A99

6.7
7.8
8.9
10
11
12
13
14
15
16
17
20
23
26
30
33
36
39
42
45
48
51

7.9
9.2
10
11
13
14
15
17
18
19
21
23
27
30
33
39
42
45
51
54
57
63

10
12
14
16
17
19
21
23
25
26
28
30
36
42
48
51
57
63
69
75
78
84

15
18
20
23
25
28
31
33
36
38
41
45
54
60
69
75
84
93
99
108
114
123

20
23
26
30
33
36
40
43
46
50
53
60
69
78
90
99
108
120
129
138
150
159

29
33
38
43
48
53
58
62
67
72
77
87
99
114
129
144
159
174
186
201
216
231

34
40
45
51
57
63
68
74
80
85
91
102
120
135
153
171
189
204
222
240
255
273

54
63
72
81
90
99
108
117
127
136
145
162
189
216
243
270
297
324
351
381
408
435

62
73
83
94
104
115
125
135
146
156
167
186
219
249
282
312
345
375
405
438
468
501

75
87
100
112
125
137
150
162
175
187
200
225
261
300
336
375
411
450
486
525
561
600

For Additional Ratings, refer to section 26.10B

Absolyte IIP Performance Characteristics Constant Current


Amperes to 1.80 Volts Per Cell @ 25C (77F)
HOURS

CELL
TYPE
50A

120

100

72

48

36

24

20

12

10

50A05
50A07
50A09
50A11
50A13
50A15
50A19

1.2
1.8
2.4
3.1
3.6
4.3
5.5

1.4
2.1
2.8
3.6
4.3
5.1
6.5

1.9
2.9
3.9
4.9
5.8
6.8
8.8

2.8
4.2
5.6
7.0
8.4
10
13

3.6
5.4
7.2
9.1
10
13
16

5.1
7.7
10
13
15
18
23

6.0
9.0
12
15
18
21
27

9.2
13
18
23
27
32
42

10
16
21
26
32
37
48

12
19
25
31
38
44
57

50A27

8.0

9.4

13

18

24

34

39

60

69

82

90A07
90A09
90A11
90A13
90A15
100A

3.0
4.0
5.0
6.0
7.0

3.5
4.7
5.9
7.1
8.3

4.8
6.4
8.0
9.7
11

6.9
9.3
11
13
16

9.0
12
15
18
21

12
17
21
25
29

14
19
24
29
34

23
31
39
46
54

27
36
45
54
63

32
43
53
64
75

100A13
100A15
100A17
100A19
100A21
100A23
100A25
100A27
100A29
100A31
100A33
100A39
100A45
100A51
100A57
100A63
100A69
100A75
100A81
100A87
100A93
100A99

6
7
8
9
11
12
13
14
15
16
17
19
23
26
29
33
36
39
42
45
48
51

7
9
10
11
13
14
15
17
18
19
20
23
27
30
33
39
42
45
51
54
57
60

10
12
14
15
17
19
21
22
24
26
28
30
36
42
45
51
57
63
66
72
78
84

15
17
20
22
25
28
30
33
35
38
40
45
51
60
66
75
84
90
99
105
114
120

19
23
26
29
32
36
39
42
46
49
52
57
69
78
87
96
108
117
126
138
147
156

28
33
38
42
47
52
57
61
66
71
76
84
99
114
126
141
156
171
183
198
213
228

33
39
45
50
56
62
67
73
78
84
90
99
117
135
150
168
186
201
219
234
252
270

53
62
71
80
89
98
107
116
125
134
143
159
186
213
240
267
294
321
348
375
402
429

62
72
82
93
103
113
124
134
144
155
165
186
216
246
279
309
339
372
402
432
465
495

73
85
97
110
122
134
146
159
171
183
195
219
255
291
330
366
402
438
477
513
549
585

90A

For Additional Ratings, refer to section 26.10B

Absolyte IIP Performance Characteristics Constant Current


Amperes to 1.90 Volts Per Cell @ 25C (77F)
HOURS

CELL
TYPE
50A

120

100

72

48

36

24

20

12

10

50A05
50A07
50A09
50A11
50A13
50A15
50A19
50A27

1.1
1.6
2.2
2.8
3.3
3.9
5.0
7.3

1.3
1.9
2.6
3.3
3.9
4.6
5.9
8.5

1.7
2.6
3.4
4.4
5.2
6.1
7.8
11

2.4
3.7
4.9
6.2
7.4
9
11
16

3.1
4.8
6.3
8.0
9.6
11
14
21

4.5
6.8
9.1
11
13
16
21
30

5.3
8.0
10
13
16
19
24
35

8.3
12
16
21
25
29
38
55

9
14
18
23
28
33
42
61

11
16
22
28
33
39
50
73

90A
90A07
90A09
90A11
90A13
90A15
100A

2.8
3.7
4.6
5.6
6.5

3.2
4.3
5.4
6.5
7.6

4.3
5.8
7.3
8.7
10

6.2
8.3
10
12
14

8.0
10
13
16
18

11
15
19
23
27

13
18
22
27
31

21
28
35
42
49

24
32
40
48
56

28
38
47
57
67

100A13
100A15
100A17
100A19
100A21
100A23
100A25
100A27
100A29
100A31
100A33
100A39
100A45
100A51
100A57
100A63
100A69
100A75
100A81
100A87
100A93
100A99

5.9
6.9
7.9
8.9
9.9
10
11
12
13
14
15
17
20
23
26
29
30
33
36
39
42
45

7.0
8.1
9.3
10
11
12
14
15
16
17
18
21
24
27
30
33
36
42
45
48
51
54

9.4
11
12
14
15
17
18
20
22
23
25
28
33
36
42
45
51
54
60
66
69
75

13
15
18
20
22
24
27
29
31
34
36
39
45
54
60
66
72
81
87
93
102
108

17
20
23
26
29
32
35
38
41
44
47
51
60
69
78
87
96
105
114
123
132
141

25
29
33
38
42
46
50
55
59
63
67
75
87
99
114
126
138
150
165
177
189
201

30
35
40
45
50
55
60
65
70
75
80
90
105
120
135
150
165
180
195
210
225
240

47
55
63
71
79
87
95
103
110
118
126
141
165
189
213
237
261
285
309
330
354
378

54
63
72
81
90
99
108
117
126
135
144
162
189
216
243
270
297
324
351
378
405
432

63
74
85
95
106
117
127
138
149
159
170
189
222
255
285
318
351
381
414
447
477
510

For Additional Ratings, refer to section 26.10B

Absolyte IIP Performance Characteristics


Cycle Life vs. Depth of Discharge [at 25C (77F)]

Open Circuit Voltage vs. State of Charge [at 25C (77F)]

Capacity Retention vs. Temperature

Absolyte IIP Performance Curves @ 25C (77F)


1 to 10 Hours

Amp-Hours/Positive

50A Series

Amps/Positive
12 to 100 Hours

Amp-Hours/Positive

50A Series

Amps/Positive

Absolyte IIP Performance Curves @ 25C (77F)


1 to 10 Hours

Amp-Hours/Positive

90A Series

Amps/Positive
12 to 100 Hours

Amp-Hours/Positive

90A Series

Amps/Positive

Absolyte IIP Performance Curves @ 25C (77F)


1 to 10 Hours

Amp-Hours/Positive

100A Series

Amps/Positive

Amp-Hours/Positive

100A Series 12 to 100 Hours

Amps/Positive

GLOBAL OPERATIONS
NORTH AMERICA
GNB Industrial Power
Chicago, Illinois U.S.A.
TEL:
1.630.629.5200
FAX:
1.630.629.2635

Industry Leader in Network Power

GNB Industrial Power


Maple, Ontario Canada
TEL:
1.905.669.9326
FAX:
1.905.669.7688
EUROPE
Exide Technologies
Budingen, Germany
TEL:
49.6042.8170
FAX:
49.6042.81233

AUSTRALIA/NEW ZEALAND
Exide Technologies
Padstow, N.S.W. Australia
TEL:
61.2.9722.5700
FAX:
61.2.9774.2966
SOUTH EAST ASIA
Exide Technologies S.E. Asia
Singapore
TEL:
65.546.2866
FAX:
65.546.2966
CHINA
Exide Technologies
Hong Kong, China
TEL:
852.3106.2668
FAX:
852.3106.0260

GNB Flooded

Based on over 100 years of technological innovation, the Network Power Division
continues to lead the industry with such recognized global brands as Absolyte,
Sonnenschein, Marathon, Sprinter, and Flooded Classic. These products and brands
are synonymous with quality, reliability, performance and excellence in all markets
served.

Total Battery Management

RN

INDIA
GNB Industrial Power
Bangalore, India
TEL:
91.80.550.0581
FAX:
91.80.550.0582

TU

LATIN AMERICA
GNB Industrial Power
Chicago, Illinois U.S.A.
TEL:
1.630.629.5200
FAX:
1.630.629.2635

Sprinter

RE

Exide Technologies
Beijing, China
TEL:
86.10.6510.2910
FAX:
86.10.6510.2912

Global Brands

AD

JAPAN
GNB Industrial Power Japan
Tokyo, Japan/Pacific Rim
TEL:
81.3.5325.6281
FAX:
81.3.5325.2063

The Network Power Division of Exide Technologies is the global leader in stored
electrical energy solutions for all major critical reserve power applications and needs.
Such network power applications include communication/data networks, UPS systems
for computers and control systems, and electrical power generation and distribution
systems. With a strong manufacturing base in both North America and Europe and a
truly global reach (operations in greater than 80 countries) in sales and service, the
Network Power Division has all of the tools necessary to satisfy your power needs.

LE

MIDDLE EAST/AFRICA
Exide Technologies
Abu Dhabi, U.A.E.
TEL:
971.2.226235
FAX:
971.2.227644

RECYCLE

In addition to being the leader in delivering premium products to the market, Exide
Technologies takes pride in its commitment to the environment. As part of a
complete approach to manufacturing, distributing, and recycling lead acid batteries,
the Total Battery Management program has been developed to ensure a safe and
responsible life cycle for all of our products.

www.gnb.com
SECTION 62.61 REV 6/02

Printed on recycled paper.